createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1716907377397
version8
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeONE_COVER
evaluationTypeTextOne Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee500.00
emd32000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose11-06-2024 16:00:00
tenderQueryClose11-06-2024 11:00:00
technicalBidOpenNone
publishedDate31-05-2024 19:57:44
publishedByPostRDPR_EE_DIV_KLB
publishedByUserKPE14101 - SATEESH GUDIGENAVAR
bidValidityPeriod90
noOfCalls3
preBidMeetingDateNone
preBidMeetingYnFalse
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnTrue
percentageRateTypeTextNone
contactPersonSateesh Gudigenavar
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumberNone
mobileNumber8472278617
tenderSupplierListNone
tenderSchedule
createdTs1716907377808
version18
createdDateNone
modifiedDateNone
tenderNumberRDPR/2023-24/BD/WORK_INDENT4178/CALL-3
titleConstruction of Anganwadi Center-3 at Deval Ghangapur Village of Afzalpur Taluka under KKRDB for the year 2022-23
descriptionConstruction of Anganwadi Center-3 at Deval Ghangapur Village of Afzalpur Taluka under KKRDB for the year 2022-23
categoryWORKS
categoryTextWorks
ecv1271210.06
deptNameRural Development and Panchayat Raj Department
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnTrue
location936
locationNameRDPR Division Office Kalaburgi
provisionalAmount1500000.0
groupOverheadTotalNone
fileNumberAEE/PRE/SD/AFZ/KKRDB/2022-23/DEVAL/GHANAGAPUR
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17169073780000NoneNoneBuildingsConstruction of Anganwadi Center-3 at Deval Ghangapur Village of Afzalpur Taluka under KKRDB for the year 2022-231271210.06
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3194436109866None001Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-chargeCum1950.91950.914.37FalseNoneNoneFalseNoneFalse28034.4330
3194437109866None002Demolishing stone rubble masonry manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material to the appropriate disposal area as per direction of Engineerin-charge.Cum1354.51354.528.35FalseNoneNoneFalseNoneFalse38400.0750
3194438109866None003Earth work excavation by manual means for drains,canals, waste weir draft, approach channels, key trench, foundation of Bridges and such similar works, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, excavated surface leveled and sides neatly dressed disposing off or leveling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work. Depth exceeding 3m, but not exceeding 4.5 mCum474.6474.664.94FalseNoneNoneFalseNoneFalse30820.5240
3194439109866None004Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite /trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregatesCum5831.75831.711.48FalseNoneNoneFalseNoneFalse66947.9160
3194440109866None005Providing Coursed rubble masonry (first sort) with hard stone in foundation and plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)Cum5820.155820.1525.74FalseNoneNoneFalseNoneFalse149810.6610
3194441109866None006Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)Cum5619.65619.615.24FalseNoneNoneFalseNoneFalse85642.7040
3194442109866None007Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum214.2214.251.98FalseNoneNoneFalseNoneFalse11134.1160
3194443109866None008Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately)M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ColoumSqm6240.156240.156.05FalseNoneNoneFalseNoneFalse37752.90750
3194444109866None009Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately)M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Centring Shuttering Charges 4% Of Concreting Rate APPENDIX I IN VOL ISqm249.61249.616.05FalseNoneNoneFalseNoneFalse1510.14050
3194445109866None010Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum6266.46266.45.9FalseNoneNoneFalseNoneFalse36971.760
3194446109866None011Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Centring Shuttering Charges 70% Of Concreting Rate APPENDIX I IN VOL ICum4386.484386.485.9FalseNoneNoneFalseNoneFalse25880.2320
3194447109866None012Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum6266.466266.463.79FalseNoneNoneFalseNoneFalse23749.88340
3194448109866None013Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Centring Shuttering Charges 50% Of Concreting RateCum3133.23133.23.79FalseNoneNoneFalseNoneFalse11874.8280
3194449109866None014Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum6491.16491.11.56FalseNoneNoneFalseNoneFalse10126.1160
3194450109866None015Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Centring Shuttering Charges 60% Of Concreting RateCum3894.663894.661.56FalseNoneNoneFalseNoneFalse6075.66960
3194451109866None016Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum6491.16491.13.32FalseNoneNoneFalseNoneFalse21550.4520
3194452109866None017Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Centring Shuttering Charges 60% Of Concreting RateCum3894.663894.663.32FalseNoneNoneFalseNoneFalse12930.27120
3194453109866None018Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum6491.16491.110.35FalseNoneNoneFalseNoneFalse67182.8850
3194454109866None019Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Centring Shuttering Charges 80% Of Concreting RateCum3245.553245.5510.35FalseNoneNoneFalseNoneFalse33591.44250
3194455109866None020Providing Thermo-Mechanically Treated bars of grade Fe-500 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately)MT96600.096600.02.79FalseNoneNoneFalseNoneFalse269514.00
3194456109866None021Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.Cum7295.47295.431.69FalseNoneNoneFalseNoneFalse231191.2260
3194457109866None022Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm326.55326.5550.69FalseNoneNoneFalseNoneFalse16552.81950
3194458109866None023Concealed Conduit System Supplying heavy gauge PVC conduit pipe ……mm dia .......mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary (25mm dia 2mm thick)Mtr70.070.050.0FalseNoneNoneFalseNoneFalse3500.00
3194459109866None024Supplying heavy gauge PVC Conduit Pipe ….dia .......mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary (25mm dia 2mm thick)(Groove)Mtr80.080.050.0FalseNoneNoneFalseNoneFalse4000.00
3194460109866None025Supplying and fixing PVC/metal conduit Deep junction box (25mm dia 2mm thick)Mtr51.051.030.0FalseNoneNoneFalseNoneFalse1530.00
3194461109866None026Supplying and flush mounting teak wooden box without front plank, made of not less than 12mm thick wood, after due groove cutting, Finishing with necessary cement plastering complete. (10"x7"x3")Each101.0101.02.0FalseNoneNoneFalseNoneFalse202.00
3194462109866None027Supplying and flush mounting teak wooden box without front plank, made of not less than 12mm thick wood, after due groove cutting, Finishing with necessary cement plastering complete. (8"x6"x3")Each75.075.02.0FalseNoneNoneFalseNoneFalse150.00
3194463109866None028Supplying and flush mounting teak wooden box without front plank, made of not less than 12mm thick wood, after due groove cutting, Finishing with necessary cement plastering complete. (4"x4"x3")Each69.069.02.0FalseNoneNoneFalseNoneFalse138.00
3194464109866None029Supplying and flush mounting teak wooden box without front plank, made of not less than 12mm thick wood, after due groove cutting, Finishing with necessary cement plastering complete.No105.0105.03.0FalseNoneNoneFalseNoneFalse315.00
3194465109866None030Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2 X1.5Sq.mm Cable confirming to the GTP, with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet / gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. GROUP A (Point Wiring)No276.0276.05.0FalseNoneNoneFalseNoneFalse1380.00
3194466109866None031Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2 X1.5Sq.mm Cable confirming to the GTP, with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet / gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. GROUP A. Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch (Point Wiring)No386.0386.05.0FalseNoneNoneFalseNoneFalse1930.00
3194467109866None032Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2 X1.5Sq.mm Cable confirming to the GTP, with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet / gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. GROUP A. Long point above 6Mtr upto 10Mtr from tapping point to out let via switch (Point Wiring)No567.0567.010.0FalseNoneNoneFalseNoneFalse5670.00
3194468109866None033Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming to GTP of GROUP -A. (1.5 Sq.mm)Mtr69.069.050.0FalseNoneNoneFalseNoneFalse3450.00
3194469109866None034Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming to GTP of GROUP -A.(2.5 Sq.mm)Mtr88.088.050.0FalseNoneNoneFalseNoneFalse4400.00
3194470109866None035Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming to GTP of GROUP -A. (4 Sq.mm)Mtr112.0112.050.0FalseNoneNoneFalseNoneFalse5600.00
3194471109866None036Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming to GTP of GROUP -A. (6 Sq.mm)Mtr158.0158.050.0FalseNoneNoneFalseNoneFalse7900.00
3194472109866None037Supplying 6A flush type socket and 6 amps flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3654 (6A 'U' Socket)Each143.0143.03.0FalseNoneNoneFalseNoneFalse429.00
3194473109866None038Supplying and fixing/replacing of 6/16/32Amps electrical accessories on existing switch board. GROUP A (6A Switches)Each121.0121.03.0FalseNoneNoneFalseNoneFalse363.00
3194474109866None039Supplying and mounting 2 Nos. of 2 way 6 amps flush type switches either surface/flush mounted on existing gang box or in 4mm thick plastic sheet and mounted on a flush mounted wooden box and wiring as per IS 1293 (2Way Switches)Each162.0162.01.0FalseNoneNoneFalseNoneFalse162.00
3194475109866None040Supply and fixing of Bakelite D.P/Socket/ switch with/without neon indicator over existing wood board or flush mounting in plastic plates/nitches as per IS 1293 and IS 3854 GROUP A (32 A Flush type DP's)Each91.091.01.0FalseNoneNoneFalseNoneFalse91.00
3194476109866None041Supply and fixing of Bakelite D.P/Socket/ switch with/without neon indicator over existing wood board or flush mounting in plastic plates/nitches as per IS 1293 and IS 3854 GROUP A (16A 'U' Socket)Each149.0149.01.0FalseNoneNoneFalseNoneFalse149.00
3194477109866None042Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system. 48" Sweep (1200mm) (Ceiling Fan)Each2085.02085.03.0FalseNoneNoneFalseNoneFalse6255.00
3194478109866None043Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clA, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure. 6 Way TP & NEach3735.03735.01.0FalseNoneNoneFalseNoneFalse3735.00
3194479109866None044Supplying & fixing of retrofit type - LED bulb ...... W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70%. efficacy 80 lumen per W, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. ( 18W Bulb)No436.0436.06.0FalseNoneNoneFalseNoneFalse2616.00
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17169073780000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17169073780000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17169073780000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17169073780000NoneNoneELIGIBILITYDepartment Registration DetailsNone
17169073780000NoneNoneELIGIBILITYTotal value of civl engineering works executed and payments received in the last five years (year-wise)None
17169073780000NoneNoneELIGIBILITYList of existing commitments and ongoing workNone
17169073780000NoneNoneELIGIBILITYList of works for which tenders already submittedNone
17169073780000NoneNoneELIGIBILITYBanker DetailsNone
17169073780000NoneNoneELIGIBILITYAll Terms & Conditions as per tender documentNone
preQualCriterionListNone
technicalCriterionListNone
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
1.The Tenderer shall have valid class -IV KPWD LicenceTrueTechnical Bid
2.To qualify for award of this contract, Each tenderer in its name should have in the last five year 2019-20 to 2023-24 Achieved in at least TWO FINANCIAL years annual turnover not less than amount put to tender attach certificated from CA on Letter Head in all classes of civil engineering construction works only with UDIN No. otherwise bid will be directly Disqualified or RejectedTrueTechnical Bid
3.To qualify for award of this contract, Each tenderer in his name should have in the last five year ie 2019-20 to 2023-24 Satisfactorily completed, as prime contractor, at least One Similar Nature of work of value not less than 50 percent of work on amount put to tender attach certificate by not below rank of Executive Engineer with Indent No from eProcurement PortalTrueTechnical Bid
4.For Less quoted rates FDR only for Each Work in favour of EE PRE Division Kalaburagi If Submitted in other forms like Bank Guarantee / Cheques and also Issued from Co operative Banks will not be accepted and Tender will be rejected without assigning any reason.TrueTechnical Bid
5.Incorrect Bid Capacity submitted by the Bidder will not be considered and the bid will be rejectedTrueTechnical Bid
6.Bidders should upload only prescribed documents for this work if unnecessary documents uploaded then bid will be directly rejectedTrueTechnical Bid
7.Valid Affidavit regarding correctness of information furnished and documents submitted by bidder should be given on Rs.100/- Stamp Paper with notary as per General condition 3.2 of KWTrueTechnical Bid
8.If Unnecessary documents uploaded by the bidder, then tender will be directly rejected and further correspondence will not be entertained declaration should be uploaded on bidders letter head duly signedTrueTechnical Bid
tenderWorkLocationList
tenderAddressNone
tenderRecallDTONone