createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1717159498798
version7
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee3300.00
emd200000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose10-06-2024 16:00:00
tenderQueryClose03-06-2024 16:00:00
technicalBidOpen12-06-2024 16:00:00
publishedDate31-05-2024 19:06:37
publishedByPostKHB_EE2_CO_BNG
publishedByUserKPE11678 - LOKESHBABU C G
bidValidityPeriod180
noOfCalls2
preBidMeetingDate04-06-2024 11:00:00
preBidMeetingYnTrue
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnTrue
percentageRateTypeTextNone
contactPersonLokesh Babu C G
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumber08022273511
mobileNumber8022273511
tenderSupplierListNone
tenderSchedule
createdTs1717159498801
version13
createdDateNone
modifiedDateNone
tenderNumberKHB/2023-24/BD/WORK_INDENT174/CALL-2
titleConstruction of Government First Grade College Building at Santebennur in Davanagere District under SDP 2021-22 Scheme
descriptionConstruction of Government First Grade College Building at Santebennur in Davanagere District under SDP 2021-22 Scheme
categoryWORKS
categoryTextWorks
ecv13164641.98
deptNameKarnataka Housing Board
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnFalse
location5488
locationNameKHB Central Office Bengaluru
provisionalAmount13164642.0
groupOverheadTotalNone
fileNumber661/2023-24
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17171594990000NoneNoneBuildingsConstruction of Government First Grade College Building at Santebennur in Davanagere District under SDP 2021-22 Scheme13164641.98
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3213965110730Nonecode01Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depth Vol-1 (pg no 8, I No 1.12)Cum68.2568.2596.0FalseNoneNoneFalseNoneFalse6552.00
3213966110730Nonecode02Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. In all kinds of soils Depth upto 3m Vol-1 (pg no 8, I No 1.14.1) a) in all types of soils 70% of qtyCum76.6576.65157.65FalseNoneNoneFalseNoneFalse12083.87250
3213967110730Nonecode03Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work ordinary rock/Soft rock / with out blasting upto 1.5m depth Vol-1 (pg no 8, I No 1.15.1) b) Soft rock /ordinary rock(with out blasting) 30% of qtyCum285.6285.666.8619FalseNoneNoneFalseNoneFalse19095.758640
3213968110730Nonecode04Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications. Vol-2 (pg no 5, I No 4.1)Sqm99.7599.75252.0FalseNoneNoneFalseNoneFalse25137.00
3213969110730Nonecode05Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates Vol-1 (pg no 15, I No 2.1.3)Cum5831.75831.742.94FalseNoneNoneFalseNoneFalse250413.1980
3213970110730Nonecode06Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates including Additional for formwork, Centering & Scaffolding for Sl No 1 a: Foundation upto plinth Isolated As per Appendix-I in Volume-1 of page No.-115 (@8% of Finished Rate) Vol-1 (pg no 15, I No 2.2.2.1)Cum6780.196780.1988.0FalseNoneNoneFalseNoneFalse596656.720
3213971110730Nonecode07Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates including Additional for formwork, Centering & Scaffolding for Sl No 8: Columns As per Appendix-I in Volume-1 of page No.-115 (@70% of Finished Rate) Vol-1 (pg no 15, I No 2.3.2)Cum10677.8710677.876.63FalseNoneNoneFalseNoneFalse70794.27810
3213972110730Nonecode08Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates including Additional for formwork, Centering & Scaffolding for Sl No 9: Earth retaining structures As per Appendix-I in Volume-1 of page No.-115 (@10% of Finished Rate) Vol-1 (pg no 15, I No 2.3.2)Cum6909.216909.215.87FalseNoneNoneFalseNoneFalse40557.06270
3213973110730Nonecode09Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. Vol-1 (pg no 7, I No 1.9)Cum214.2214.2321.22FalseNoneNoneFalseNoneFalse68805.3240
3213974110730Nonecode10Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)Columns M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. including Additional for formwork, Centering & Scaffolding for Sl No 8 : Columns As per Appendix-I in Volume-1 of page No.-115 (@70% of Finished Rate) Ground Floor Vol-1 (pg no 17, I No 2.5.2)Cum11042.0111042.0112.7FalseNoneNoneFalseNoneFalse140233.5270
3213975110730Nonecode11Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. including Additional for formwork, Centering & Scaffolding for Sl No 1.a Plinth beam of buildings As per Appendix-I in Volume-1 of page No.-115 (@50% of Finished Rate) Ground Floor Vol-1 (pg no 17, I No 2.5.2)Cum9742.959742.9513.83FalseNoneNoneFalseNoneFalse134744.99850
3213976110730Nonecode12Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. including Additional for formwork, Centering & Scaffolding for Sl No 12 : beam & lintels of buildings As per Appendix-I in Volume-1 of page No.-115 (@60% of Finished Rate) Ground Floor Vol-1 (pg no 17, I No 2.5.2)Cum10392.4810392.4821.72FalseNoneNoneFalseNoneFalse225724.66560
3213977110730Nonecode13Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. including Additional for formwork, Centering & Scaffolding for Sl No 20 : Chejjas, Canopy & Other Architectural projections of minor sections As per Appendix-I in Volume-1 of page No.-115 (@45% of Finished Rate)Ground Floor Vol-1 (pg no 17, I No 2.5.2)Cum9418.199418.191.95FalseNoneNoneFalseNoneFalse18365.47050
3213978110730Nonecode14Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. including Additional for formwork, Centering & Scaffolding for Sl No 13 : Roof slab of Buildings As per Appendix-I in Volume-1 of page No.-115 (@50% of Finished Rate) Ground Floor Vol-1 (pg no 17, I No 2.5.2)Cum9742.959742.9543.03FalseNoneNoneFalseNoneFalse419239.13850
3213979110730Nonecode15Dismantling weather proof course and removing and conveying the debris to a distance to the appropriate disposal area as per direction of Engineer-in-charge. Vol-2 (pg no 169, I No 19.59)Cum472.31472.3133.72FalseNoneNoneFalseNoneFalse15926.29320
3213980110730Nonecode16Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material to the appropriate disposal area as per direction of Engineer-in-charge. Vol-2 (pg no 165, I No 19.27.1)Sqm88.8988.8920.4FalseNoneNoneFalseNoneFalse1813.3560
3213981110730Nonecode17Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge. In lime mortar Vol-2 (pg no 163, I No 19.7.2)Cum478.74478.7417.65FalseNoneNoneFalseNoneFalse8449.7610
3213982110730Nonecode18Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates including Additional for formwork, Centering & Scaffolding for Sl No 8 : Columns As per Appendix-I in Volume-1 of page No.-115 (@70% of Finished Rate) Vol-1 (pg no 17, I No 2.5.2) Second FloorCum11262.8511262.8512.63FalseNoneNoneFalseNoneFalse142249.79550
3213983110730Nonecode19Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates including Additional for formwork, Centering & Scaffolding for Sl No 12 : beam & lintels of buildings As per Appendix-I in Volume-1 of page No.-115 (@60% of Finished Rate) Vol-1 (pg no 17, I No 2.5.2) Second FloorCum10600.3310600.3321.18FalseNoneNoneFalseNoneFalse224514.98940
3213984110730Nonecode20Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates including Additional for formwork, Centering & Scaffolding for Sl No 20 : Chejjas, Canopy & Other Architectural projections of minor sections As per Appendix-I in Volume-1 of page No.-115 (@45% of Finished Rate) Vol-1 (pg no 17, I No 2.5.2) Second FloorCum9606.559606.552.1FalseNoneNoneFalseNoneFalse20173.7550
3213985110730Nonecode21Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates including Additional for formwork, Centering & Scaffolding for Sl No 13 : Roof slab of Buildings As per Appendix-I in Volume-1 of page No.-115 (@50% of Finished Rate) Vol-1 (pg no 17, I No 2.5.2) Second FloorCum9937.819937.8158.16FalseNoneNoneFalseNoneFalse577983.02960
3213986110730Nonecode22Providing Thermo-Mechanically Treated bars of grade Fe-550 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) Vol-2 (pg no 84, I No 11.32) Ground FloorKg87.1587.1517888.48FalseNoneNoneFalseNoneFalse1558981.0320
3213987110730Nonecode23Providing Thermo-Mechanically Treated bars of grade Fe-550 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) Vol-2 (pg no 84, I No 11.32) Second FloorKg88.8988.8910755.74FalseNoneNoneFalseNoneFalse956077.72860
3213988110730Nonecode24Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. Vol-2 (pg no 14, I No 6.8) Ground FloorCum7024.57024.575.88FalseNoneNoneFalseNoneFalse533019.060
3213989110730Nonecode25Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. Vol-2 (pg no 14, I No 6.8) Second FloorCum7164.997164.9997.23FalseNoneNoneFalseNoneFalse696651.97770
3213990110730Nonecode26Providing Half Brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. Vol-2 (pg no 14, I No 6.15) Ground FloorSqm909.3909.377.6FalseNoneNoneFalseNoneFalse70561.680
3213991110730Nonecode27Providing Half Brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. Vol-2 (pg no 14, I No 6.15) Second FloorSqm927.49927.4916.26FalseNoneNoneFalseNoneFalse15080.98740
3213992110730Nonecode28Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) Mix 1:2:4 (M15) Using 20 mm nominal size graded crushed coarse aggregates Vol-1 (pg no 17, I No 2.4.1) Ground FloorCum6174.06174.03.81FalseNoneNoneFalseNoneFalse23522.940
3213993110730Nonecode29Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) Mix 1:2:4 (M15) Using 20 mm nominal size graded crushed coarse aggregates Vol-1 (pg no 17, I No 2.4.1) Second FloorCum6297.486297.487.77FalseNoneNoneFalseNoneFalse48931.41960
3213994110730Nonecode30Providing 12 mm cement plaster with cement mortar 1:4 (1 cement:4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Vol-2 (pg no 41, I No 8.1.1) Ground FloorSqm223.65223.65364.43FalseNoneNoneFalseNoneFalse81504.76950
3213995110730Nonecode31Providing 12 mm cement plaster with cement mortar 1:4 (1 cement:4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Vol-2 (pg no 41, I No 8.1.1) Second FloorSqm228.12228.12377.33FalseNoneNoneFalseNoneFalse86076.51960
3213996110730Nonecode32Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Vol-2 (pg no 41, I No 8.2.1) Ground FloorSqm260.4260.4817.28FalseNoneNoneFalseNoneFalse212819.7120
3213997110730Nonecode33Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Vol-2 (pg no 41, I No 8.2.1) Second FloorSqm265.61265.61621.81FalseNoneNoneFalseNoneFalse165158.95410
3213998110730Nonecode34Providing 20 mm cement plaster of mix :1:6 (1 cement: 6 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Vol-2 (pg no 41, I No 8.2.1) Ground FloorSqm289.8289.8593.6FalseNoneNoneFalseNoneFalse172025.280
3213999110730Nonecode35Providing 20 mm cement plaster of mix :1:6 (1 cement: 6 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Vol-2 (pg no 41, I No 8.2.1) Second FloorSqm295.6295.6788.82FalseNoneNoneFalseNoneFalse233175.1920
3214000110730Nonecode36Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 20 mm to 25 mm wide to required depth. Vol-2 (pg no 54, I No 8.80) Ground Floorm53.5553.55200.0FalseNoneNoneFalseNoneFalse10710.00
3214001110730Nonecode37Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 20 mm to 25 mm wide to required depth. Vol-2 (pg no 54, I No 8.80) Second Floorm54.6254.62200.0FalseNoneNoneFalseNoneFalse10924.00
3214002110730Nonecode38Providing lath plaster with cement mortar 1:3, 5cms thick with 6mm dia mild steel bars at 20 cms. c to c both horizontally and vertically fixing chicken mesh for drop chajja, facia, backing to cup boards including cost of all materials, labour, providing and removing form work HOM of machineries, curing, complete as per specifications. Specification No. KBS padadi works for arches as per design & drawing Vol-2 (sl no 8, I No 8.83) Ground FloorSqm1233.751233.759.23FalseNoneNoneFalseNoneFalse11387.51250
3214003110730Nonecode39Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mm Vol-2 (pg no 61, I No 9.17.2) Ground FloorSqm1157.11157.1219.26FalseNoneNoneFalseNoneFalse253705.7460
3214004110730Nonecode40Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mm Vol-2 (pg no 61, I No 9.17.2) Second FloorSqm1180.241180.24221.72FalseNoneNoneFalseNoneFalse261682.81280
3214005110730Nonecode41Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. Vol-2 (pg no 60, I No 9.11) Ground FloorSqm800.1800.110.15FalseNoneNoneFalseNoneFalse8121.0150
3214006110730Nonecode42Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. Vol-2 (pg no 60, I No 9.11) Second FloorSqm816.1816.127.68FalseNoneNoneFalseNoneFalse22589.6480
3214007110730Nonecode43Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. Vol-2 (pg no 65, I No 9.39) Ground FloorSqm1088.851088.8530.37FalseNoneNoneFalseNoneFalse33068.37450
3214008110730Nonecode44Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. Vol-2 (pg no 65, I No 9.39) Second FloorSqm1110.631110.6391.92FalseNoneNoneFalseNoneFalse102089.10960
3214009110730Nonecode45Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slabover 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent. Vol-2 (pg no 63, I No 9.24) Ground FloorSqm3013.53013.536.05FalseNoneNoneFalseNoneFalse108636.6750
3214010110730Nonecode46Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slabover 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent. Vol-2 (pg no 63, I No 9.24) Second FloorSqm3073.773073.77132.81FalseNoneNoneFalseNoneFalse408227.39370
3214011110730Nonecode47Providing edge moulding to 18mm thick Granite stone counters, vanities etc including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-charge Vol-2 (pg no 69, I No 10.20) Ground Floorm282.45282.4580.1FalseNoneNoneFalseNoneFalse22624.2450
3214012110730Nonecode48Providing edge moulding to 18mm thick Granite stone counters, vanities etc including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-charge Vol-2 (pg no 69, I No 10.20) Second Floorm288.1288.150.0FalseNoneNoneFalseNoneFalse14405.00
3214013110730Nonecode49Providing Mathi/Nandi wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications. Vol-2 (pg no 100, I No 12.12) Ground FloorCum79111.279111.20.68FalseNoneNoneFalseNoneFalse53795.6160
3214014110730Nonecode50Providing Mathi/Nandi wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications. Vol-2 (pg no 100, I No 12.12) Second FloorCum80693.4280693.420.65FalseNoneNoneFalseNoneFalse52450.7230
3214015110730Nonecode51Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. Vol-2 (pg no 105, I No 12.51) Ground FloorNos1555.051555.057.0FalseNoneNoneFalseNoneFalse10885.350
3214016110730Nonecode52Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. Vol-2 (pg no 105, I No 12.51) Second FloorNos1586.151586.156.0FalseNoneNoneFalseNoneFalse9516.90
3214017110730Nonecode53Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 35 mm thick both side commercial Vol-2 (pg no 106, I No 12.57.6) Ground FloorSqm3091.23091.219.44FalseNoneNoneFalseNoneFalse60092.9280
3214018110730Nonecode54Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 35 mm thick both side commercial Vol-2 (pg no 106, I No 12.57.6) Second FloorSqm3153.023153.0216.8FalseNoneNoneFalseNoneFalse52970.7360
3214019110730Nonecode55Providing & fixing Factory made single extruded wood polymer Composite (WPC) solid door/window, clerestory windows & frames / chowkat of frame size 65 x 100 mm Vol-2 (sl no 28, I No 12.93) Ground floorm729.75729.7517.1FalseNoneNoneFalseNoneFalse12478.7250
3214020110730Nonecode56Providing & fixing Factory made single extruded wood polymer Composite (WPC) solid door/window, clerestory windows & frames / chowkat of frame size 65 x 100 mm Vol-2 (sl no 28, I No 12.93) Second Floorm744.35744.3522.8FalseNoneNoneFalseNoneFalse16971.180
3214021110730Nonecode57Providing & fixing Factory made 100% carpenter friendly ready to use single soild plain wood polymer Composite (WPC) flush shutter of 30mm thickness which is antitermite and having high water absorption property. The cost includes cost of materials transportation, labour and fixing charges. Vol-2 (sl no 31, I No 12.96) Ground floorSqm3651.93651.94.73FalseNoneNoneFalseNoneFalse17273.4870
3214022110730Nonecode58Providing & fixing Factory made 100% carpenter friendly ready to use single soild plain wood polymer Composite (WPC) flush shutter of 30mm thickness which is antitermite and having high water absorption property. The cost includes cost of materials transportation, labour and fixing charges. Vol-2 (sl no 31, I No 12.96) Second FloorSqm3724.943724.946.3FalseNoneNoneFalseNoneFalse23467.1220
3214023110730Nonecode59Providing & fixing of 2-track x 2-panel sliding windows made out of multichambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having a overall size of 60mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm X 58mm with GI reinforcement of 1mm for the frame and 1.5 mm for the sash. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 2-2.5 mm. Maximum possible size 1819mm x 1819mm (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) Vol-2 (pg no 111, I No 12.88) Ground FloorSqm6731.556731.5537.83FalseNoneNoneFalseNoneFalse254654.53650
3214024110730Nonecode60Providing & fixing of 2-track x 2-panel sliding windows made out of multichambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having a overall size of 60mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm X 58mm with GI reinforcement of 1mm for the frame and 1.5 mm for the sash. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 2-2.5 mm. Maximum possible size 1819mm x 1819mm (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) Vol-2 (pg no 111, I No 12.88) Second FloorSqm6866.186866.1833.0FalseNoneNoneFalseNoneFalse226583.940
3214025110730Nonecode61Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) Vol-2 (pg no 110, I No 12.85) Ground FloorSqm5113.55113.51.44FalseNoneNoneFalseNoneFalse7363.440
3214026110730Nonecode62Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) Vol-2 (pg no 110, I No 12.85) Second FloorSqm5215.775215.778.28FalseNoneNoneFalseNoneFalse43186.57560
3214027110730Nonecode63Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc. Vol-2 (pg no 85, I No 11.34B) Ground FloorKg150.15150.15858.69FalseNoneNoneFalseNoneFalse128932.30350
3214028110730Nonecode64Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc. Vol-2 (pg no 85, I No 11.34B) Second FloorKg153.15153.15866.88FalseNoneNoneFalseNoneFalse132762.6720
3214029110730Nonecode65Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. Vol-2 (pg no 50 I No 8.51) Ground FloorSqm87.1587.151151.35FalseNoneNoneFalseNoneFalse100340.15250
3214030110730Nonecode66Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. Vol-2 (pg no 50 I No 8.51) Second FloorSqm88.8988.89907.23FalseNoneNoneFalseNoneFalse80643.67470
3214031110730Nonecode67Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Special primer applied @ 0.75 ltr /10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Vol-2 (pg no 46, I No 8.33.1) Ground FloorSqm123.9123.91151.35FalseNoneNoneFalseNoneFalse142652.2650
3214032110730Nonecode68Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Special primer applied @ 0.75 ltr /10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Vol-2 (pg no 46, I No 8.33.1) Second FloorSqm126.38126.38907.23FalseNoneNoneFalseNoneFalse114655.72740
3214033110730Nonecode69Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Vol-2 (pg no 46, I No 8.32) Ground FloorSqm117.6117.6984.02FalseNoneNoneFalseNoneFalse115720.7520
3214034110730Nonecode70Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Vol-2 (pg no 46, I No 8.32) First FloorSqm118.78118.78345.38FalseNoneNoneFalseNoneFalse41024.23640
3214035110730Nonecode71Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Vol-2 (pg no 46, I No 8.32) Second FloorSqm119.95119.95788.82FalseNoneNoneFalseNoneFalse94618.9590
3214036110730Nonecode72Painting wood work with Deluxe Multi Surface Paint of required shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @0.75 ltr/10 m² of approved brand and manufacture to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Vol-2 (pg no 46, I No 8.33.2) Ground FloorSqm110.25110.2523.87FalseNoneNoneFalseNoneFalse2631.66750
3214037110730Nonecode73Painting wood work with Deluxe Multi Surface Paint of required shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @0.75 ltr/10 m² of approved brand and manufacture to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Vol-2 (pg no 46, I No 8.33.2) Second FloorSqm112.46112.4620.24FalseNoneNoneFalseNoneFalse2276.19040
3214038110730Nonecode74Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @ 0.80 ltr/10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Vol-2 (pg no 47, I No 8.33.3) Ground FloorSqm111.3111.340.89FalseNoneNoneFalseNoneFalse4551.0570
3214039110730Nonecode75Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @ 0.80 ltr/10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Vol-2 (pg no 47, I No 8.33.3) Second FloorSqm113.53113.5341.28FalseNoneNoneFalseNoneFalse4686.51840
3214040110730Nonecode76Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. Vol-2 (pg no 83, I No 11.28) Ground FloorKg525.0525.0162.0FalseNoneNoneFalseNoneFalse85050.00
3214041110730Nonecode77Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. Vol-2 (pg no 83, I No 11.28) Second FloorKg535.5535.581.0FalseNoneNoneFalseNoneFalse43375.50
3214042110730Nonecode78Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge. Vol-2 (pg no 133, I No 15.10) Second FloorSqm797.9797.9337.47FalseNoneNoneFalseNoneFalse269267.3130
3214043110730Nonecode79Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs,laid to slope compacting, including cost of materials, labour, curing complete as per specifications. Vol-2 (pg no 23, I No 7.18) Second FloorCum2160.212160.2117.34FalseNoneNoneFalseNoneFalse37458.04140
3214044110730Nonecode80Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. Vol-2 (pg no 81, I No 11.16.1)Kg115.59115.5971.28FalseNoneNoneFalseNoneFalse8239.25520
3214045110730Nonecode81Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. Vol-2 (pg no 26, I No 7.38)Sqm589.64589.6424.22FalseNoneNoneFalseNoneFalse14281.08080
3214046110730Nonecode82Providing and fixing Chorinated poly venyl cloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings,this includes jointing of pipes and fitting with one step CPVC solvent cement,trenching,refilling & testing of joints complete as per direction of Engineer incharge (external work) Vol-2 (Sl no 11, I No 13.33.3) Item No 13.87.3 (25mm nominal OD pipes) Vol-2 (Sl no 11, I No 13.33.3)m313.95313.95150.0FalseNoneNoneFalseNoneFalse47092.50
3214047110730Nonecode83Providing and fixing Chorinated poly venyl cloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings,this includes jointing of pipes and fitting with one step CPVC solvent cement,trenching,refilling & testing of joints complete as per direction of Engineer incharge (external work) Vol-2 (Sl no 11, I No 13.33.3) Item No 13.87.5 (40mm nominal OD pipes) Vol-2 (Sl no 11, I No 13.33.5)m492.45492.4550.0FalseNoneNoneFalseNoneFalse24622.50
3214048110730Nonecode84Providing and fixing Chorinated poly venyl cloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings,this includes jointing of pipes and fitting with one step CPVC solvent cement,trenching,refilling & testing of joints complete as per direction of Engineer incharge (external work) Vol-2 (Sl no 11, I No 13.33.3) Item No 13.33.6 (50mm nominal OD pipes) Vol-2 (Sl no 11, I No 13.33.6)m737.1737.160.0FalseNoneNoneFalseNoneFalse44226.00
3214049110730Nonecode85Providing and fixing Chorinated poly venyl cloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr spacing. This includes jointing of pipes and fitting with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer incharge. (Concealed work including cutting chases and good the walls etc.,.) Item No 13.86.2 (20mm nominal OD pipes) Vol-2 (Sl no 10, I No 13.32.2)m391.65391.6580.0FalseNoneNoneFalseNoneFalse31332.00
3214050110730Nonecode86Providing and fixing Chorinated poly venyl cloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr spacing. This includes jointing of pipes and fitting with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer incharge. (Concealed work including cutting chases and good the walls etc.,.) Item No 13.86.3 (25mm nominal OD pipes) Vol-2 (Sl no 10, I No 13.32.2)m499.8499.835.0FalseNoneNoneFalseNoneFalse17493.00
3214051110730Nonecode87Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 25 mm nominal bore Vol-2 (pg no 115, I No 13.4.1)Each554.4554.44.0FalseNoneNoneFalseNoneFalse2217.60
3214052110730Nonecode88Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 40 mm nominal bore Vol-2 (pg no 115, I No 13.4.3)Each715.05715.052.0FalseNoneNoneFalseNoneFalse1430.10
3214053110730Nonecode89Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 50 mm nominal bore Vol-2 (pg no 115, I No 13.4.4)Each875.7875.72.0FalseNoneNoneFalseNoneFalse1751.40
3214054110730Nonecode90Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 g. Vol-2 (pg no 117, I No 13.14)Nos707.7707.77.0FalseNoneNoneFalseNoneFalse4953.90
3214055110730Nonecode91Cutting holes up to 15x15cm in R.C.C floors and roofs for passing drain pipe etc., and repairing the hole after insertion of drain pipe etc., with cement concrete 1:2:4 (1cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) including finishing complete so as to make it leak proof Vol-2 (sl no 16, I No 13.37)No255.15255.1550.0FalseNoneNoneFalseNoneFalse12757.50
3214056110730Nonecode92Cutting holes up to 30x30cm in walls including making good the same with common burnt clay F.P.S (non modular) bricks Vol-2 (sl no 15, I No 13.36)Each279.3279.340.0FalseNoneNoneFalseNoneFalse11172.00
3214057110730Nonecode93Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 Vol-2 (pg no 117, I No 13.16)Nos517.65517.6520.0FalseNoneNoneFalseNoneFalse10353.00
3214058110730Nonecode94Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for PVC pipes 75mm dia., 6 kg/sqcm & class 3 Vol-5 (pg no 134, I No 1.50)m220.5220.540.0FalseNoneNoneFalseNoneFalse8820.00
3214059110730Nonecode95Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. PVC pipes 110mm dia., 6 kg/sqcm & class 3 Vol-5 (pg no 134, I No 1.70)m413.7413.790.0FalseNoneNoneFalseNoneFalse37233.00
3214060110730Nonecode96Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring confirming to IS : 5383, leaving 10mm gap for termal expansion (i) single socketed pepes 100mm diameter Vol-5 (sl no 27, I No 13.48)m265.65265.6547.4FalseNoneNoneFalseNoneFalse12591.810
3214061110730Nonecode97Providing and placing on terrace, (at all floor levels) polyethylene water storage tanks IS : 12701 marked with cover and suitable locking arrangements, and making necessary holes for inlet, outlet and over flow pipes, but without fittings and the base support for tank Vol-5 (sl no 12, I No 13.34)l8.48.46000.0FalseNoneNoneFalseNoneFalse50400.00
3214062110730Nonecode98Earth work excavation for pipeline trenches in all kinds of soils by mechanical means above 600 mm trench width as per drawing and technical specifications, including setting out, construction of shoring, strutting, barricading, caution lights, bracing, using sight rails & boning rods at every 100 mm whevere necessary as directed, removal of stumps and other deleterious matter, dressing of sides and levelling the bottom of trench to the extent required , utilising the available excavated earth locally for the work etc., and all other appurtenances complete in the following strata All kinds of soils. Depth upto 1.50 m Vol-1 (pg no 10, I No 1.17.1)Cum203.7203.769.75FalseNoneNoneFalseNoneFalse14208.0750
3214063110730Nonecode99Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m , and lift upto 1.5 m. Including cost of all labour complete as per specifications Vol-1 (pg no 7, I No 1.10)Cum128.1128.154.0FalseNoneNoneFalseNoneFalse6917.40
3214064110730Nonecode100Supplying, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc. Note: Upto 110mm dia Coil shall be used. For Grade PE80 PN8.0 : HDPE Grade PE80-PN8.0,140mm dia Vol-5 (pg no 122, I No 2.60)m885.0885.010.0FalseNoneNoneFalseNoneFalse8850.00
3214065110730Nonecode101Supplying, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc. Note: Upto 110mm dia Coil shall be used. For Grade PE80 PN8.0 : HDPE Grade PE80-PN8.0,200mm dia Vol-5 (pg no 122, I No 2.90)m1689.811689.8150.0FalseNoneNoneFalseNoneFalse84490.50
3214066110730Nonecode102Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid Vol-2 (pg no 123, I No 14.3.1)Each5255.255255.254.0FalseNoneNoneFalseNoneFalse21021.00
3214067110730Nonecode103Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests Vol-2 (pg no 123, I No 14.1.1)Each4458.34458.33.0FalseNoneNoneFalseNoneFalse13374.90
3214068110730Nonecode104Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps Vol-2 (pg no 124, I No 14.7.1)Each2655.452655.456.0FalseNoneNoneFalseNoneFalse15932.70
3214069110730Nonecode105Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g. Vol-2 (pg no 130, I No 14.40.2)Each399.0399.06.0FalseNoneNoneFalseNoneFalse2394.00
3214070110730Nonecode106Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flushpipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :Vol-2 (pg no 123, I No 14.4.1)Each3712.83712.86.0FalseNoneNoneFalseNoneFalse22276.80
3214071110730Nonecode107Constructing brick masonry chamber of internal dimension 300x230mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover Vol-5 (pg no 187, I No T130E)Each2661.752661.753.0FalseNoneNoneFalseNoneFalse7985.250
3214072110730Nonecode108Providing and fixing 100 mm sand cast Iron grating for gully trap Vol-2 (pg no 128, I No 14.29)Each215.25215.253.0FalseNoneNoneFalseNoneFalse645.750
3214073110730Nonecode109Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.. Vol-5 (pg no 187, I No T130B)Each5225.855225.857.0FalseNoneNoneFalseNoneFalse36580.950
3214074110730Nonecode110Supplying and fixing SFRC frame and cover conforming to IS 12592 (part-I)-1988 and IS 12592 (part-II)- 1991 with latest amendment, including cutting slabs to the required size for the opening and fixing the cover in C.C. 1:2:4 and C.M. 1:3 plastering 20 mm thick to all exposed faces, curing for 10 days with all lead and lift with appurtenances. complete Medium Duty Vol-5 (pg no 192, I No T380A)Each1854.31854.37.0FalseNoneNoneFalseNoneFalse12980.10
3214075110730Nonecode111Concealed conduit system :supplying……mm dia 2mm 2.5mm thick heavy guage PVC conduit pipe with suitable size bends, metal/PVC junction boxes adhesive pasteetc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused wires and unused junction boxes and pipe ends should be covered using PVC end enclosers. Run with 18 SWG GI fish wire wherever necessary a) 19/20mm dia 2mm thickMtr61.061.0620.0FalseNoneNoneFalseNoneFalse37820.00
3214076110730Nonecode112Concealed conduit system :supplying……mm dia 2mm 2.5mm thick heavy guage PVC conduit pipe with suitable size bends, metal/PVC junction boxes adhesive pasteetc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused wires and unused junction boxes and pipe ends should be covered using PVC end enclosers. Run with 18 SWG GI fish wire wherever necessary b) 25mm dia 2mm thickMtr70.070.0400.0FalseNoneNoneFalseNoneFalse28000.00
3214077110730Nonecode113Groove cutting : supplying…….dia 2mm/2.5mm thick heavy guage PVC conduit pipe with bends, metal junction boxes adhesive paste etc., and bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. a) 19/20mm dia 2mm thickMtr75.075.0350.0FalseNoneNoneFalseNoneFalse26250.00
3214078110730Nonecode114Groove cutting : supplying…….dia 2mm/2.5mm thick heavy guage PVC conduit pipe with bends, metal junction boxes adhesive paste etc., and bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. b) 25mm dia 2mm thickMtr80.080.0180.0FalseNoneNoneFalseNoneFalse14400.00
3214079110730Nonecode115Point wiring using copper wire without switch. Supplying and wiring adopting loop system in existin PVC conduit /casing caping using copper PVC insulated multi strand 2x1.5Sqmm copper wire without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block.complete outlet. Short point upto 3Mtr from tapping point to outlet via switch boxPoint251.0251.035.0FalseNoneNoneFalseNoneFalse8785.00
3214080110730Nonecode116Point wiring using copper wire without switch. Supplying and wiring adopting loop system in existin PVC conduit /casing caping using copper PVC insulated multi strand 2x1.5Sqmm copper wire without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block.complete outlet. medium point above 3Mtr upto 6Mtr from tapping point outlet via switch boxPoint361.0361.060.0FalseNoneNoneFalseNoneFalse21660.00
3214081110730Nonecode117Point wiring using copper wire without switch. Supplying and wiring adopting loop system in existin PVC conduit /casing caping using copper PVC insulated multi strand 2x1.5Sqmm copper wire without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block.complete outlet. long point above 6Mtr upto 10Mtr tapping point to outlet via switch boxPoint542.0542.080.0FalseNoneNoneFalseNoneFalse43360.00
3214082110730Nonecode118Point wiring using copper wire without switch. Supplying and wiring adopting loop system in existin PVC conduit /casing caping using copper PVC insulated multi strand 2x1.5Sqmm copper wire without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block.complete outlet. long Two outlet in a row, above 3 Mtr upto 6Mtr from tapping point to outlet let via switchesPoint671.0671.04.0FalseNoneNoneFalseNoneFalse2684.00
3214083110730Nonecode119Supplying and flush mounting powder coated metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in brick/stone /c.c wall 1-3 wayEach123.0123.05.0FalseNoneNoneFalseNoneFalse615.00
3214084110730Nonecode120Supplying and flush mounting powder coated metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in brick/stone /c.c wall 4-5 wayEach138.0138.05.0FalseNoneNoneFalseNoneFalse690.00
3214085110730Nonecode121Supplying and flush mounting powder coated metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in brick/stone /c.c wall 6 wayEach212.0212.020.0FalseNoneNoneFalseNoneFalse4240.00
3214086110730Nonecode122Supplying and flush mounting powder coated metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in brick/stone /c.c wall 8 wayEach250.0250.04.0FalseNoneNoneFalseNoneFalse1000.00
3214087110730Nonecode123Supplying and flush mounting powder coated metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in brick/stone /c.c wall 10-12 wayEach325.0325.012.0FalseNoneNoneFalseNoneFalse3900.00
3214088110730Nonecode124Supplying and flush mounting powder coated metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in brick/stone /c.c wall 16 wayEach354.0354.012.0FalseNoneNoneFalseNoneFalse4248.00
3214089110730Nonecode125Supplying and fixing superior quality modular switch mounting poly carbonate plate with necessary supporting back plate with required nos. of machine screws, bolts, nuts etc., complete on the existing metal/PVC box. 1to 3 moduleEach152.0152.05.0FalseNoneNoneFalseNoneFalse760.00
3214090110730Nonecode126Supplying and fixing superior quality modular switch mounting poly carbonate plate with necessary supporting back plate with required nos. of machine screws, bolts, nuts etc., complete on the existing metal/PVC box. 4 moduleEach175.0175.05.0FalseNoneNoneFalseNoneFalse875.00
3214091110730Nonecode127Supplying and fixing superior quality modular switch mounting poly carbonate plate with necessary supporting back plate with required nos. of machine screws, bolts, nuts etc., complete on the existing metal/PVC box. 6 moduleEach244.0244.020.0FalseNoneNoneFalseNoneFalse4880.00
3214092110730Nonecode128Supplying and fixing superior quality modular switch mounting poly carbonate plate with necessary supporting back plate with required nos. of machine screws, bolts, nuts etc., complete on the existing metal/PVC box. 8 moduleEach302.0302.04.0FalseNoneNoneFalseNoneFalse1208.00
3214093110730Nonecode129Supplying and fixing superior quality modular switch mounting poly carbonate plate with necessary supporting back plate with required nos. of machine screws, bolts, nuts etc., complete on the existing metal/PVC box. 12 moduleEach363.0363.012.0FalseNoneNoneFalseNoneFalse4356.00
3214094110730Nonecode130Supplying and fixing superior quality modular switch mounting poly carbonate plate with necessary supporting back plate with required nos. of machine screws, bolts, nuts etc., complete on the existing metal/PVC box. 16 ModuleEach403.0403.012.0FalseNoneNoneFalseNoneFalse4836.00
3214095110730Nonecode131Supplying and fixing of modular switch/socket /stepped electronic fan regulator/dimmer/telephone socket etc on excistin modular switch plate. Using group 'A' materials 6Amps one wayEach88.088.0275.0FalseNoneNoneFalseNoneFalse24200.00
3214096110730Nonecode132Supplying and fixing of modular switch/socket /stepped electronic fan regulator/dimmer/telephone socket etc on excistin modular switch plate. Using group 'A' materials 6Amps 2 wayEach152.0152.02.0FalseNoneNoneFalseNoneFalse304.00
3214097110730Nonecode133Supplying and fixing of modular switch/socket /stepped electronic fan regulator/dimmer/telephone socket etc on excistin modular switch plate. Using group 'A' materials 6Amps 3 way socketEach162.0162.035.0FalseNoneNoneFalseNoneFalse5670.00
3214098110730Nonecode134Supplying and fixing of modular switch/socket /stepped electronic fan regulator/dimmer/telephone socket etc on excistin modular switch plate. Using group 'A' materials Stepped fan regulatorEach313.0313.050.0FalseNoneNoneFalseNoneFalse15650.00
3214099110730Nonecode135Supplying and fixing of modular switch/socket /stepped electronic fan regulator/dimmer/telephone socket etc on excistin modular switch plate. Using group 'A' materials 16Amps 1 way switchEach249.0249.05.0FalseNoneNoneFalseNoneFalse1245.00
3214100110730Nonecode136Supplying and fixing of modular switch/socket /stepped electronic fan regulator/dimmer/telephone socket etc on excistin modular switch plate. Using group 'A' materials 32Amps DP switchEach375.0375.05.0FalseNoneNoneFalseNoneFalse1875.00
3214101110730Nonecode137Supplying and fixing of modular switch/socket /stepped electronic fan regulator/dimmer/telephone socket etc on excistin modular switch plate. Using group 'A' materials 6/16Amps universal socketEach249.0249.05.0FalseNoneNoneFalseNoneFalse1245.00
3214102110730Nonecode138Supplying and fixing of modular switch/socket /stepped electronic fan regulator/dimmer/telephone socket etc on excistin modular switch plate. Using group 'A' materials TV/Telephone socketEach147.0147.05.0FalseNoneNoneFalseNoneFalse735.00
3214103110730Nonecode139Supplying and fixing of modular switch/socket /stepped electronic fan regulator/dimmer/telephone socket etc on excistin modular switch plate. Using group 'A' materials RJ45/I.O outletEach211.0211.05.0FalseNoneNoneFalseNoneFalse1055.00
3214104110730Nonecode140Wiring for lighting or power circuit using one of FRLS PVC insulated 1100v grade,multis and copper with low conductor resistance single core wire in open or consealed system of wiring with specified IS-694:1990 & confirming to GTP Group 'A' material 1.5 SqmmMtr26.026.01100.0FalseNoneNoneFalseNoneFalse28600.00
3214105110730Nonecode141Wiring for lighting or power circuit using one of FRLS PVC insulated 1100v grade,multis and copper with low conductor resistance single core wire in open or consealed system of wiring with specified IS-694:1990 & confirming to GTP Group 'A' material 2.5 SqmmMtr40.040.02150.0FalseNoneNoneFalseNoneFalse86000.00
3214106110730Nonecode142Wiring for lighting or power circuit using one of FRLS PVC insulated 1100v grade,multis and copper with low conductor resistance single core wire in open or consealed system of wiring with specified IS-694:1990 & confirming to GTP Group 'A' material 4 SqmmMtr59.059.0500.0FalseNoneNoneFalseNoneFalse29500.00
3214107110730Nonecode143Wiring for lighting or power circuit using one of FRLS PVC insulated 1100v grade,multis and copper with low conductor resistance single core wire in open or consealed system of wiring with specified IS-694:1990 & confirming to GTP Group 'A' material 6 SqmmMtr87.087.0300.0FalseNoneNoneFalseNoneFalse26100.00
3214108110730Nonecode144Wiring for lighting or power circuit using one of FRLS PVC insulated 1100v grade,multis and copper with low conductor resistance single core wire in open or consealed system of wiring with specified IS-694:1990 & confirming to GTP Group 'A' material 10 SqmmMtr157.0157.0200.0FalseNoneNoneFalseNoneFalse31400.00
3214109110730Nonecode145Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG MS enclosure.III - Double Door 6Way TP &NEach3735.03735.03.0FalseNoneNoneFalseNoneFalse11205.00
3214110110730Nonecode146Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG MS enclosure.II - Double Door 16Way SP &NEach2650.02650.02.0FalseNoneNoneFalseNoneFalse5300.00
3214111110730Nonecode147Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 amps SPEach523.0523.030.0FalseNoneNoneFalseNoneFalse15690.00
3214112110730Nonecode148Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 amps DPEach1103.01103.020.0FalseNoneNoneFalseNoneFalse22060.00
3214113110730Nonecode149Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker [ELMCB] 240/450V up to 300mA sensitivity on existing wood/panel board. 63 Amps 4 poleEach3058.03058.05.0FalseNoneNoneFalseNoneFalse15290.00
3214114110730Nonecode150Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40mm dia 2.90mm thick GI pipe 2.5 mtr long buried in a pit … The pit should be filled with equal proportion of salt and charcoal 150mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per ISI specification 7.3.3. of IS 732 using 12mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm diaNos2999.72999.76.0FalseNoneNoneFalseNoneFalse17998.20
3214115110730Nonecode151Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x6mm GI StripMtr115.0115.020.0FalseNoneNoneFalseNoneFalse2300.00
3214116110730Nonecode152Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x3mm Copper StripMtr505.0505.030.0FalseNoneNoneFalseNoneFalse15150.00
3214117110730Nonecode153Supplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc. 8 SWG copper wireMtr105.0105.040.0FalseNoneNoneFalseNoneFalse4200.00
3214118110730Nonecode154Supplying of PVC Batten with integrated LED tube LED light fighting 1 x4'- 36/40 w with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.Each1197.01197.0105.0FalseNoneNoneFalseNoneFalse125685.00
3214119110730Nonecode155Supplying & fixing of retrofit type - LED bulb.......W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70%. efficacy 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 9W, 6500KEach160.0160.04.0FalseNoneNoneFalseNoneFalse640.00
3214120110730Nonecode156Extra for supplying 4mm thick white plastic plate and covering for junction boxes of size 110mm conduite using necessary machine screws.No12.012.0250.0FalseNoneNoneFalseNoneFalse3000.00
3214121110730Nonecode157Supplying & Fixing of 230 Volts 20/40 watts Fluorescent Lamp holderEach17.017.0180.0FalseNoneNoneFalseNoneFalse3060.00
3214122110730Nonecode158Supplying of 1440rpm heavy duty exhuast fan with bracket blades suitable for operate on 230V 50Hz,AC supply complete. 15" Sweep (450mm)Each4126.04126.08.0FalseNoneNoneFalseNoneFalse33008.00
3214123110730Nonecode159Supplying and fixing Metal Fan Box with Round HookNo163.0163.050.0FalseNoneNoneFalseNoneFalse8150.00
3214124110730Nonecode160Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts,50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system. 48" Sweep (1200mm) Regular model (Khaitan,Crompton Greaves,Orient,Polar,Bajaj,Havells,Almonard)Each2085.02085.050.0FalseNoneNoneFalseNoneFalse104250.00
3214125110730Nonecode161Fixing all types and all capacities fluorecent/false ceiling/spot light/CFL fittings indoor on the wall / rafter / girders using 23/0.0076" twin twisted PVC insulated wires, required nos of round blocks and clamps (if required)a)On wall/ceiling/Rafters/GirdersEach119.0119.0109.0FalseNoneNoneFalseNoneFalse12971.00
3214126110730Nonecode162Fixing a ceiling/wall mounting fan of all capacities and all types to the existing S hook together with supplying and fixing a 5 amperes ceiling rose,necessary lenth of 23/0.0076 inch PVC insluted twisted copper wire and wiring completely.Each162.0162.050.0FalseNoneNoneFalseNoneFalse8100.00
3214127110730Nonecode163Fixing one exhaust fan in the nitch alredy left in the walls with the bolts and nuts and 5amps ceiling rose with sufficient lenth of 23/0.0076 inch PVC insulated twin core wire of approved make.Each432.0432.08.0FalseNoneNoneFalseNoneFalse3456.00
3214128110730Nonecode164Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms(Max) as per IS-3975 3.5 core 70 sqmm TC to panelMtr350.0350.050.0FalseNoneNoneFalseNoneFalse17500.00
3214129110730Nonecode165Digging of trench of 0.6m deep x 0.50 mtr wide refiling the trench to the required ground level and consolidating etc., complete. In soil (Ordinary)Mtr76.076.050.0FalseNoneNoneFalseNoneFalse3800.00
3214130110730Nonecode166Labour charges for laying of 1.1 KV class UG cable in existing trench GI pipe / stoneware pipe / on wall / on pole as required. 25sqmm to 75 sqmm TC to panelMtr15.515.550.0FalseNoneNoneFalseNoneFalse775.00
3214131110730Nonecode167Supplying tinnd copper lugs and crimping and wiring to terminal point for wire of the following sizes 70 sqmm Long BarrelEach95.095.010.0FalseNoneNoneFalseNoneFalse950.00
3214132110730Nonecode168Supplying and fixingof heavy duty cable glands suitable or UG cable o 1.1KV class (metal only) 45 mm diaEach194.0194.02.0FalseNoneNoneFalseNoneFalse388.00
3214133110730Nonecode169Supplying and fixing L.T. cast Iron pot heads suitable for 1.1 KV class UG cable filled with necessary bitumen/insulating compound complete with terminals, clamps, bolts, nuts and washers etc.70SqmmEach622.0622.03.0FalseNoneNoneFalseNoneFalse1866.00
3214134110730Nonecode170Supplying, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc. Note: Upto 110mm dia Coil shall be used. For Grade PE80 PN6.0 : HDPE Grade PE80-PN6. 75mm dia (5/p 121 / I K010B) m 184m184.0184.050.0FalseNoneNoneFalseNoneFalse9200.00
3214135110730Nonecode171Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts and wiring complete. Protection of Overload and Short circuit with thermal Magnetic/Microprocessed release and Earth Fault as per IS-13947. ( Icu = Ics)(34/9) FOUR POLE 5.14.9)160Amps 25kAEach8500.08500.01.0FalseNoneNoneFalseNoneFalse8500.00
3214136110730Nonecode172Supplying of multi function digital meter with three line back light LCD type display for voltage,Current,frequency,Power, Powerfactor,KVA,KWH,KVARsuitable for 3 Phase,4 wire LT network with IP 54 degree of protection and completely wired as required wuth communication Port and Class 0.5s accuracy.Each7750.07750.01.0FalseNoneNoneFalseNoneFalse7750.00
3214137110730Nonecode173Supplying,fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based,digital readout of percentage leakage current,programable delay/auto/manual reset facility suitable to mount on DIN rail/flush mounting on panel board.Each7700.07700.01.0FalseNoneNoneFalseNoneFalse7700.00
3214138110730Nonecode174Supplying, fixing and wiring 50/5A to 400/5A 5VA Burden class 1 Current Transformer.Each700.0700.02.0FalseNoneNoneFalseNoneFalse1400.00
3214139110730Nonecode175Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and wiring complete as required. 5.17.9)50-63Amps TPNEach2397.02397.06.0FalseNoneNoneFalseNoneFalse14382.00
3214140110730Nonecode176Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and wiring complete as required. 5.17.6)50-63Amps DPEach1365.01365.02.0FalseNoneNoneFalseNoneFalse2730.00
3214141110730Nonecode177Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and wiring complete as required. 5.17.4)6-32Amps DPEach909.0909.02.0FalseNoneNoneFalseNoneFalse1818.00
3214142110730Nonecode178Supplying,fixing and Fixing of Shunt trip suitable for MCCB. CBCTEach1400.01400.03.0FalseNoneNoneFalseNoneFalse4200.00
3214143110730Nonecode179Supplying …..amps rated 3phase with netural bus bar using required capacity electrolytic alluminium strips covered with heat shrinkable coloured PVC sleeve,mounted on phenolic/ERP/DMC insulator which are mounted on powder coated 40x6 mm M.S.flat frame work in existing panel board.The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts,nuts and washers etc.,complete. 5.40.1)100Amps 4x30x6mm Alluminium StripsMtr2050.02050.02.0FalseNoneNoneFalseNoneFalse4100.00
3214144110730Nonecode180Supplying …..amps rated 3phase with netural bus bar using required capacity electrolytic alluminium strips covered with heat shrinkable coloured PVC sleeve,mounted on phenolic/ERP/DMC insulator which are mounted on powder coated 40x6 mm M.S.flat frame work in existing panel board.The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts,nuts and washers etc.,complete. 5.40.2)250Amps 4x30x10mm Alluminium StripsMtr2850.02850.02.0FalseNoneNoneFalseNoneFalse5700.00
3214145110730Nonecode181Supplying …..amps rated 3phase with netural bus bar using required capacity electrolytic alluminium strips covered with heat shrinkable coloured PVC sleeve,mounted on phenolic/ERP/DMC insulator which are mounted on powder coated 40x6 mm M.S.flat frame work in existing panel board.The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts,nuts and washers etc.,complete. 5.40.3)400Amps 4x50x10mm Alluminium StripsMtr3700.03700.02.0FalseNoneNoneFalseNoneFalse7400.00
3214146110730Nonecode182Fabricating supplying and mounting MS box made out 16 SWG suitable for floor/wall mounting,fully weather proof with provision for better heat dissipation, provided with hinged front cover,equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete. 14 SWGSq CM0.40.4108000.0FalseNoneNoneFalseNoneFalse43200.00
3214147110730Nonecode183Supplying and fixing of LED type pannel board indicating lamp with reqired colour suitable for 220v A.C.50 Hz 12/24v D.C.Each430.0430.03.0FalseNoneNoneFalseNoneFalse1290.00
3214148110730Nonecode184Supplying of an load change over switches 4 poles AC-23A Duty 415V, 50Hz, AC Supply (Open Execution) 100 AmpsEach5500.05500.01.0FalseNoneNoneFalseNoneFalse5500.00
3214149110730Nonecode185Providing and fixing Aluminium fixtures like Aldrops of size 300x16mm, Tower Bolts of size 200x12mm, 100mm length oxidised iron Hinges, Handles of size 150mm, Door Stopper, Locking arrangements & Door Bush of aprroved make and quality including cost and Conveyance of all materials and as per thre direction of EIC of work with all lead and lift and directed by the engineer in charge of works. Double Shutter.(oxidised Iron Hinges -8),(Door Stopper 2 ), (Tower Bolt-3), Handles-4), (Aldrops-1), (Brass Door Bush -2),Locking Arrangements-1). Approved rate,DOC Chikkamangalore Ground FloorNos5698.185698.185.0FalseNoneNoneFalseNoneFalse28490.90
3214150110730Nonecode186Providing and fixing Aluminium fixtures like Aldrops of size 300x16mm, Tower Bolts of size 200x12mm, 100mm length oxidised iron Hinges, Handles of size 150mm, Door Stopper, Locking arrangements & Door Bush of aprroved make and quality including cost and Conveyance of all materials and as per thre direction of EIC of work with all lead and lift and directed by the engineer in charge of works. Double Shutter.(oxidised Iron Hinges -8),(Door Stopper 2 ), (Tower Bolt-3), Handles-4), (Aldrops-1), (Brass Door Bush -2),Locking Arrangements-1). Approved rate,DOC Chikkamangalore Second FloorNos5698.185698.185.0FalseNoneNoneFalseNoneFalse28490.90
3214151110730Nonecode187Providing and fixing Aluminium fixtures like Aldrops of size 300x16mm, Tower Bolts of size 200x12mm, 100mm length oxidised iron Hinges, Handles of size 150mm, Door Stopper, Locking arrangements & Door Bush of aprroved make and quality including cost and Conveyance of all materials and as per thre direction of EIC of work with all lead and lift and directed by the engineer in charge of works. Single Shutter.(oxidised Iron Hinges -8),(Door Stopper 2 ), (Tower Bolt-3), Handles-4), (Aldrops-1), (Brass Door Bush -2),Locking Arrangements-1). Approved rate,DOC Chikkamangalore Ground FloorNos3689.183689.1812.0FalseNoneNoneFalseNoneFalse44270.160
3214152110730Nonecode188Providing and fixing Aluminium fixtures like Aldrops of size 300x16mm, Tower Bolts of size 200x12mm, 100mm length oxidised iron Hinges, Handles of size 150mm, Door Stopper, Locking arrangements & Door Bush of aprroved make and quality including cost and Conveyance of all materials and as per thre direction of EIC of work with all lead and lift and directed by the engineer in charge of works. Single Shutter.(oxidised Iron Hinges -8),(Door Stopper 2 ), (Tower Bolt-3), Handles-4), (Aldrops-1), (Brass Door Bush -2),Locking Arrangements-1). Approved rate,DOC Chikkamangalore Second FloorNos3689.183689.185.0FalseNoneNoneFalseNoneFalse18445.90
3214153110730Nonecode189Providing and fixing Green board of size 3.00mx1.2m with ceramic steel scratch resistance Magnetic Green Chalk Board including cost of materials, labour with neccesorry fixtures and fastnings as per the direction of engineer incharge Approved rate,GFGC Dharwad.Each12300.012300.03.0FalseNoneNoneFalseNoneFalse36900.00
3214154110730Nonecode190Providing and fixing Testing and commissioning of CP Health faucet consisting of 1 No. 15mm dia CP Angle cock with wall flage.PVC flexible tube of 1m long tube with end nuts. Hand operated spray unit (instent type)CP Crutch etc, complete as directed by the Engineer in charge. Approved Rate DOC ChikkamangaluruEach1145.541145.544.0FalseNoneNoneFalseNoneFalse4582.160
3214155110730Nonecode191Provoding & fixing testing and commissioning u PVC multi inlet floor trap conforming to IS 13592 with required P C support placed to required level as per site condition complete. 110mm dia inlet 75mm dia outlet , Make: PRINCE / ASHIRWAD / SUPREME / equivalent Approve rate Raichur Krishi Vishwa vidyanilayaNos141.86141.8610.0FalseNoneNoneFalseNoneFalse1418.60
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17171594990000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17171594990000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17171594990000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17171594990000NoneNoneELIGIBILITYThe tender document is part and parcel of the agreement.None
17171594990000NoneNoneELIGIBILITYThe contractor shall obtain insurance coverage for all the workers deployed for this work.None
17171594990000NoneNoneELIGIBILITYFurther details of the work or any clarifications can be obtained from the office of the Executive Engineer (Central office), KHB, Cauvery Bhavan, K.G. Road, Bangalore Ph: 080-22273511 ext-317,None
17171594990000NoneNoneELIGIBILITYThe intending bidders are requested to note that they should abide by the detailed instructions and conditions contained in the Tender documents and further modifications done if any.None
17171594990000NoneNoneELIGIBILITYCorrigendum/modification/corrections, if any, will be published in the e procurement Web sites only.None
17171594990000NoneNoneELIGIBILITYKHB reserves the right to withdraw or cancel this invitation to BID/Tender without assigning any reason whatsoeverNone
17171594990000NoneNoneELIGIBILITYThe bidder shall study the Tender document Carefully and quote the ratesNone
17171594990000NoneNoneELIGIBILITYAll scanned documents to be uploaded shall be in original and are to be produced to the Executive Engineer to verify the documents within 3 days from the day of opening of Technical bid for verification, if required.None
17171594990000NoneNoneELIGIBILITYDrawings uploaded are only for Tender Purpose only.None
17171594990000NoneNoneELIGIBILITYGST shall be added separately in the estimate.None
17171594990000NoneNoneELIGIBILITYGST shall be paid to the tendered amount separately.None
17171594990000NoneNoneELIGIBILITYThe bidder should maintain register of laborers deployed and wages paid for the workers and shall produce the documents whenever called for by the competent authority. Remittance towards PF shall be commensurate with the labour component of the work involved.None
17171594990000NoneNoneELIGIBILITYThe bidder shall give an undertaking that they would abide by the provisions of employees provident fund and shall remit PF of labourers to the respective PF offices or else KHB have the right to deduct the PF amount from the work bills and remit the same to respective PF offices.None
17171594990000NoneNoneELIGIBILITYThe contractor shall quote his rates inclusive of PF as per the applicable rate as issued by the PF department from time to timeNone
17171594990000NoneNoneELIGIBILITYThe successful bidder shall give an under taking that they would abide by the provisions of the Employees Provident Fund Act.None
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneMinimum financial turnover (civil engineering construction works) not less than two times the annual payments from this contract (Rs. xxxxx Lakhs)NoneNone
NoneNoneNoneNoneSatisfactoriy completed (atleast 90%) as prime contractor at-least one such similar work of value not less than Rs. xxxxxxx (80% of estimated cost of tender)NoneNone
NoneNoneNoneNoneExecuted in any one year the following minimum quantities of work (Cement Concrete - xxxx cum, Earthwork - xxxx cum, etc) (80% of peak rate of construction)NoneNone
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid Electrical License for executing building electrificatio works and should have executed similar electrical works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid license for executing water supply / sanitary engineering works and should have executed similar works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneOwning the following key and critical equipment for this work (xxxx, xxxx, xxxx)NoneNone
NoneNoneNoneNoneLiquid assets and /or availability of credit facilities of no less than Rs. xxxxxx Lakhs (estimated cash flow for 3 months of peak construction period)NoneNone
NoneNoneNoneNoneTotal value of civl engineering works executed and payments received in the last five years (year-wise)NoneNone
NoneNoneNoneNoneList of existing commitments and ongoing worksNoneNone
NoneNoneNoneNoneList of works for which tenders already submittedNoneNone
NoneNoneNoneNoneBanker Details for referenceNoneNone
NoneNoneNoneNoneConstruction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneReports on the financial standing of the tenderer, such as profit and loss statements and auditor’s reports for the last five yearsNoneNone
NoneNoneNoneNoneQualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneList of Financial Resources with CertificatesNoneNone
NoneNoneNoneNoneScanned Copy of documentary proof for having executed similar nature of work not less than 50% of tender amount as defined in Government order No.FD 480 EXP-12/2014,Bangalore dated:19.07.2014Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneScanned copy of latest GST clearance certificate.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Scanned copy of latest GST clearance certificate.
NoneNoneNoneNoneScanned copy of Pre-qualification letter issued by Karnataka Housing Board.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Scanned copy of Pre-qualification letter issued by Karnataka Housing Board.
NoneNoneNoneNoneAs per Tender Documents KW-4 clause 3.3 key & critical equipments available.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- As per Tender Documents KW-4 clause 3.3 key & critical equipments available.
NoneNoneNoneNoneExecuted in any one Financial year, the minimum quantities of work as mentioned in tender documentCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Executed in any one Financial year, the minimum quantities of work as mentioned in tender document
NoneNoneNoneNoneRequired valid electrical license for executing similar nature of work as per tender documentCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Required valid electrical license for executing similar nature of work as per tender document
NoneNoneNoneNoneThe Tenderer should have executed similar water supply/sanitary engineering works as per tender documentCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- The Tenderer should have executed similar water supply/sanitary engineering works as per tender document
NoneNoneNoneNoneIncome Tax returns & PANFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneITR Filed Copy (Mentioning PAN)
NoneNoneNoneNoneGST Registration CertificateFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneGST Registration
NoneNoneNoneNoneTo qualify for award of this contract , each tenderer in its name should have in the last five years achieved in at least two financial years a minimum financial turnover (In all classes of civil engineering construction works only)Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNoneScanned copy of Credit lines/ letter of credit /Bankers certificate for at least 20% of amount put to tender in the current financial year on the name of work put to tender.Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneLine of Credit
NoneNoneNoneNoneAssessed Available Bid Capacity as per tender documentFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Assessed Available Bid Capacity as per tender document
NoneNoneNoneNoneCovering letter.OthersCovering letter.
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Covering letter.
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Annual Turnover CertificateTrueTechnical Bid
Company Registration CertificateFalseTechnical Bid
Reserved Category CertificateFalseTechnical Bid
Small Scale Industries CertificateFalseTechnical Bid
Work done certificateTrueTechnical Bid
key and critical equipment LISTTrueTechnical Bid
Income Tax returns & PAN no.TrueTechnical Bid
Pre-qualification certificate issued by KHBTrueTechnical Bid
GST clearance certificateTrueTechnical Bid
Credit lines/ letter of credit/Bankers certificateTrueTechnical Bid
Assessed available tender capacity calculationTrueTechnical Bid
Electrical licenseTrueTechnical Bid
Work done certificate with quantitiesTrueTechnical Bid
tenderWorkLocationList
tenderAddress
createdTs1717161018000
version0
createdDateNone
modifiedDateNone
blockNumberCAUVERY BHAVAN 3RD FLOOR
streetNone
cityBengaluru
stateKarnataka
pin560009
tenderRecallDTONone