tenderSubEstimateList | createdTs | version | createdDate | modifiedDate | workCategoryName | subEstimateName | estimateTotal | itemList |
---|
1717145222000 | 0 | None | None | Buildings | Construction of a Room to G.H.P School at Alagalivada Village in Harapanahalli Taluk, Vijayanagar District. | 863387.87 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3210111 | 110480 | None | PWD SR.2021-22, V1, Pg-8 Item No.1.14 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. In all kinds of soils Depth upto 3 m | Cum | 107.1 | 107.1 | 36.02 | False | None | None | False | None | False | 3857.742 | 0 | 3210112 | 110480 | None | PWD SR.2023-24, V1, Pg-15 Item No.2.1.2 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates | Cum | 5947.2 | 5947.2 | 11.65 | False | None | None | False | None | False | 69284.88 | 0 | 3210113 | 110480 | None | PWD SR.2023-24, V2, Pg-9 Item No.5.3 | Providing Coursed rubble masonry (second sort) with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 6515.25 | 6515.25 | 13.42 | False | None | None | False | None | False | 87434.655 | 0 | 3210114 | 110480 | None | PWD SR.2023-24, V2, Pg-9 Item No.5.4 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 6708.45 | 6708.45 | 7.64 | False | None | None | False | None | False | 51252.558 | 0 | 3210115 | 110480 | None | PWD SR.2023-24, V1, Pg-15 Item No.2.1.4 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6527.85 | 6527.85 | 1.29 | False | None | None | False | None | False | 8420.9265 | 0 | 3210116 | 110480 | None | PWD SR.2023-24, V2, Pg-44, Item No8.19.1 | Providing Flush/ Ruled pointing: Pointing on stone work with cement mortar 1:3 (1 cement : 3 fine sand) after raking joints to depth nicely lining, including cost of materials, labour, curing as per specifications and as per directions of Engineer-in-charge. | Sqm | 267.75 | 267.75 | 13.89 | False | None | None | False | None | False | 3719.0475 | 0 | 3210117 | 110480 | None | PWD DSR.2023-24, V1, Pg-7, Item No1.9 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth,consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | Cum | 279.3 | 279.3 | 26.24 | False | None | None | False | None | False | 7328.832 | 0 | 3210118 | 110480 | None | PWD SR.2023-24, V2, Pg-14, Item No.6.8 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. | Cum | 8367.45 | 8367.45 | 14.37 | False | None | None | False | None | False | 120240.2565 | 0 | 3210119 | 110480 | None | PWD SR.2023-24, V1, Pg-15, Item No.2.2.1 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately)M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6601.35 | 6601.35 | 3.89 | False | None | None | False | None | False | 25679.2515 | 0 | 3210120 | 110480 | None | PWD SR.2023-24, V1, Pg-111, Item No.1 b | Formwork,Centering & Scaffolding for footing 8 percent | Cum | 528.11 | 528.11 | 3.89 | False | None | None | False | None | False | 2054.3479 | 0 | 3210121 | 110480 | None | PWD SR.2023-24, V1, Pg-16, Item No.2.5.1 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6961.5 | 6961.5 | 3.94 | False | None | None | False | None | False | 27428.31 | 0 | 3210122 | 110480 | None | PWD SR.2023-24, V1, Pg-111, Item No.9 | Formwork,Centering & Scaffolding for Column - 70 percent | Cum | 4873.05 | 4873.05 | 3.94 | False | None | None | False | None | False | 19199.817 | 0 | 3210123 | 110480 | None | PWD SR.2023-24, V1, Pg-16, Item No.2.3.1 | Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6639.15 | 6639.15 | 1.93 | False | None | None | False | None | False | 12813.5595 | 0 | 3210124 | 110480 | None | PWD SR.2023-24, V1, Pg-111,Item No.2 | Formwork,Centering & Scaffolding for Plinth beam 50 percent | Cum | 3319.58 | 3319.58 | 1.93 | False | None | None | False | None | False | 6406.7894 | 0 | 3210125 | 110480 | None | PWD SR.2023-24, V1, Pg-16, Item No.2.5.1 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6961.5 | 6961.5 | 0.85 | False | None | None | False | None | False | 5917.275 | 0 | 3210126 | 110480 | None | PWD SR.2023-24, V1, Pg-112, Item No.14 | Formwork,Centering & Scaffolding for Lintel 60percent | Cum | 3983.49 | 3983.49 | 0.85 | False | None | None | False | None | False | 3385.9665 | 0 | 3210127 | 110480 | None | PWD SR.2023-24, V1, Pg-16, Item No.2.5.1 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6961.5 | 6961.5 | 2.5 | False | None | None | False | None | False | 17403.75 | 0 | 3210128 | 110480 | None | PWD SR.2023-24, V1, Pg-112, Item No.14 | Formwork,Centering & Scaffolding for Roof Beam 60 percent | Cum | 4176.9 | 4176.9 | 2.5 | False | None | None | False | None | False | 10442.25 | 0 | 3210129 | 110480 | None | PWD SR.2023-24, V1, Pg-16, Item No.2.5.1 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6961.5 | 6961.5 | 10.28 | False | None | None | False | None | False | 71564.22 | 0 | 3210130 | 110480 | None | PWD SR.2023-24, V1, Pg-112, Item No.15 | Formwork,Centering & Scaffolding for Roof slab 50 percent | Cum | 3480.75 | 3480.75 | 10.28 | False | None | None | False | None | False | 35782.11 | 0 | 3210131 | 110480 | None | PWD SR.2023-24, V1, Pg-16, Item No.2.5.1 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. | Cum | 6961.5 | 6961.5 | 0.14 | False | None | None | False | None | False | 974.61 | 0 | 3210132 | 110480 | None | PWD SR.2023-24, V1, Pg-112 Item No.19 | Formwork,Centering & Scaffolding for Chejja 45 percent | Cum | 2987.62 | 2987.62 | 0.14 | False | None | None | False | None | False | 418.2668 | 0 | 3210133 | 110480 | None | PWD SR.2023-24, V2, Pg-41, Item No.8.2.1 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding,including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 383.5 | 383.5 | 95.16 | False | None | None | False | None | False | 36493.86 | 0 | 3210134 | 110480 | None | PWD SR.2023-24, V2, Pg-77, Item No. 11.5.1 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-inCharge. | Sqm | 4701.9 | 4701.9 | 2.52 | False | None | None | False | None | False | 11848.788 | 0 | 3210135 | 110480 | None | PWD SR.2023-24, V2, Pg-79, Item No.11.11.1 | Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Sqm | 155.4 | 155.4 | 149.04 | False | None | None | False | None | False | 23160.816 | 0 | 3210136 | 110480 | None | PWD SR.2023-24, V2, Pg-86, Item No.11.34A | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding | Kg | 176.4 | 176.4 | 136.08 | False | None | None | False | None | False | 24004.512 | 0 | 3210137 | 110480 | None | PWD SR.2023-24, V2, Pg-64, Item No.9.35 | Flooring with 25mm thick polished shahabad slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab, , including cost of materials, labour, curing, polishing complete as per specifications. | Sqm | 1717.8 | 1717.8 | 50.56 | False | None | None | False | None | False | 86851.968 | 0 | 3210138 | 110480 | None | PWD SR.2023-24, V2, Pg-65, Item No.9.38 | Providing skirting, dadooing, rises of steps with white glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour,complete as per specifications. | Sqm | 1461.6 | 1461.6 | 4.53 | False | None | None | False | None | False | 6621.048 | 0 | 3210139 | 110480 | None | PWD SR.2023-24, V2, Pg-45, Item No.8.25 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 178.1 | 178.1 | 118.75 | False | None | None | False | None | False | 21149.375 | 0 | 3210140 | 110480 | None | PWD SR.2023-24, V2, Pg-45, Item No.8.28 | Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 115.7 | 115.7 | 86.48 | False | None | None | False | None | False | 10005.736 | 0 | 3210141 | 110480 | None | PWD SR.2023-24, V2, Pg-47, Item No.8.33.3 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @ 0.80 ltr/10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 180.7 | 180.7 | 19.1 | False | None | None | False | None | False | 3451.37 | 0 | 3210142 | 110480 | None | PWD SR.2023-24, V2, Pg-84, Item No.11.26.1 | Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. M.S. tube including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineerin- Charge. | Kg | 144.9 | 144.9 | 115.5 | False | None | None | False | None | False | 16735.95 | 0 | 3210143 | 110480 | None | PWD SR. 2023-24, V-3, Pg- 78, I No.-8.54 | Providing and fixing board displaying information, such as 'Name of work, Tender cost, Name of Contractor, Work completion and liability period etc', having rectangular shape of 1.20m x 0.90m size made out 18 gauge (1.25mm) thick mild steel sheet painted with one coat of Zinc chromate stoving primer and two coats of enamel paint on front side and grey stove enamel on back side and border / messages / symbols etc. with approved colour shade paint complete, on M.S.angle of size 35 x 35 x 3 mm frame with properly cross braced M.S. angles of size 35mmx35mmx3mm duly painted including Two M.S. angle iron posts of size 65 mm x 65 mm x 6 mm, 3.65 m long painted with alternate black and white bands of 25 cm width including all fixtures etc.and fixing the boards in 1:4:8 concrete block of size 60 cm x 60 cm x 75 cm including, excavation, refilling, transportation, and labour etc complete. Spec. No. As directed by Engineer in Charge & MoRTH specification 804 (P-188, I.No.21 C 4) | No | 9450.0 | 9450.0 | 1.0 | False | None | None | False | None | False | 9450.0 | 0 | 3210144 | 110480 | None | PWD SR.2023-24 V2 Pg-41 Item No.8.1.1 | Providing 12 mm cement plaster with cement mortar 1:4 (1 cement:
4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 331.5 | 331.5 | 68.19 | False | None | None | False | None | False | 22604.985 | 0 |
| 1717145222000 | 0 | None | None | Buildings | Construction of a Room to G.H.P School at Alagalivada Village in Harapanahalli Taluk, Vijayanagar District - SDP | 220320.87 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3210145 | 110481 | None | PWD SR.2023-24, V1, Pg-18, Item No.2.11a | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening,cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.Buildings | t | 93929.85 | 93929.85 | 1.91 | False | None | None | False | None | False | 179406.0135 | 0 | 3210146 | 110481 | None | UNI SR23-24,PWD,Elec,Vol-6,P-3,C-1,I- 1.2.1,Pg2 | Concealed Conduit System Supplying heavy gauge PVC conduit pipe 19/20mm dia 2mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary | m | 66.0 | 66.0 | 32.0 | False | None | None | False | None | False | 2112.0 | 0 | 3210147 | 110481 | None | UNISR23-24,PWD,Elec,Vol-6,P-3,C-2,I.No- 2.2.1,Pg5 | Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistr and FRLS PVC insulated, 2X1.5Sq.mm Cable confirming to the GTP without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet. Short point upto 3Mtr from tapping point to out let via switch box.Short point upto 3Mtr from tapping point to out let via switch box. | Point | 269.0 | 269.0 | 2.4 | False | None | None | False | None | False | 645.6 | 0 | 3210148 | 110481 | None | UNISR23-24,PWD,Elec,Vol-6,P-3,C-2,It.No-2.2.2,Pg.5 | Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit/casing cappingcasing capping using 2x1.5Sqmm (Phase&Neutral) & 1x1.0sqmm (Earthwire)FRLS multistrand PVC insulated copperwire (confirming to IS-694: and latest amendments) without controls witch shall be fixed on the existing plasticsheet/gangbox ,the other end of the wires shall be terminated with sufficient looselength in a wood/PVC round block. complete for each outlet. Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch box | Point | 379.0 | 379.0 | 12.0 | False | None | None | False | None | False | 4548.0 | 0 | 3210149 | 110481 | None | UNISR23-24,PWD,Elec,Vol-6,P-3,C-2,It.No-2.2.3,Pg.5 | Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit/casing capping casing capping using 2x1.5Sqmm (Phase&Neutral) & 1x1.0sqmm (Earthwire)FRLS multistrand PVC insulated copperwire (confirmingtoIS-694 : and latest amendments) without controls witch shall be fixed on the existing plasticsheet/gangbox ,the other end of the wires shall be terminated with sufficient looselength in a wood/PVC round block. complete for each outlet. Long point above 6Mtr upto 10Mtr from tapping point to out let via switch box | Point | 555.0 | 555.0 | 6.0 | False | None | None | False | None | False | 3330.0 | 0 | 3210150 | 110481 | None | UNISR23-24,PWD,Elec,Vol6,P-3,C-3,It.No-3.14.6,Pg10 | Supplying and fixing/replacing of 6/16/32Amps electrical accessories on existing switch board. 6Amps lamp holder | Each | 71.0 | 71.0 | 5.0 | False | None | None | False | None | False | 355.0 | 0 | 3210151 | 110481 | None | SR23-24,PWD,Elec,Vol-6,P-3,C-11,It.No-11.3.2,Pg43 | Supplying of .feet - PVC Batten with integrated LED tube.W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI greater than 80. Power Input: 220-240V @ 50/60Hz & Power factor greater than 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED Light fighting 1 x4'- 20/22 w | Each | 690.0 | 690.0 | 5.0 | False | None | None | False | None | False | 3450.0 | 0 | 3210152 | 110481 | None | SR23-24,PWD,Elec,Vol-6,P-3,C-13,It.No-13.7.1,Pg56 | Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall / ceiling / Rafter / Girders | Each | 122.0 | 122.0 | 5.0 | False | None | None | False | None | False | 610.0 | 0 | 3210153 | 110481 | None | SR23-24,PWD,Elec,Vol-6,P-3,C-6,It.No-6.3.2,Pg30 | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system. 48" Sweep (1200mm) Regular model | Each | 3031.0 | 3031.0 | 2.0 | False | None | None | False | None | False | 6062.0 | 0 | 3210154 | 110481 | None | SR23-24,PWD,Elec,Vol-6,P-3,C-13,It.No-13.10,Pg57 | Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S' hook with fan regulator to the existing board together with supplying and fixing 5 amps. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring. | Each | 171.0 | 171.0 | 2.0 | False | None | None | False | None | False | 342.0 | 0 | 3210155 | 110481 | None | SR23-24,PWD,Elec,Vol-6,P-3,C-3,It.No-3.6.4,Pg9 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 Stepped fan regulator. | Each | 357.0 | 357.0 | 2.0 | False | None | None | False | None | False | 714.0 | 0 | 3210156 | 110481 | None | SR23-24,PWD,Elec,Vol-6,P-3,C-3,It.No-3.5.6,Pg8 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. - 12Module | Each | 344.0 | 344.0 | 2.0 | False | None | None | False | None | False | 688.0 | 0 | 3210157 | 110481 | None | SR23-24,PWD,Elec,Vol-6,P-3,C-3,It.No-3.4.6,Pg8 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall - 10-12Way | Each | 319.0 | 319.0 | 2.0 | False | None | None | False | None | False | 638.0 | 0 | 3210158 | 110481 | None | SR23-24,PWD,Elec,Vol-6,P-3,C-3,It.No-3.6.1,Pg9 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 .6A one way switch. | Each | 102.0 | 102.0 | 5.0 | False | None | None | False | None | False | 510.0 | 0 | 3210159 | 110481 | None | SR23-24,PWD,Elec,Vol-6,P-3,C-3,It.No-3.6.3,Pg9 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.6A Three way socket. | Each | 171.0 | 171.0 | 3.0 | False | None | None | False | None | False | 513.0 | 0 | 3210160 | 110481 | None | SR23-24,PWD,Elec,Vol-6,P-3,C-3,It.No-3.14.5,Pg10 | Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board. 6A Bakelite Ceiling Rose. | Each | 78.0 | 78.0 | 2.0 | False | None | None | False | None | False | 156.0 | 0 | 3210161 | 110481 | None | SR23-24,PWD,Elec,Vol-6,P-3,C-5,It.No-5.6.6,Pg14 | Supply and fixing polished wood board made of not less than 15mm thick plank on both sides of not more than 2 pieces and fixing the same to the wall using tapered inverted wooden plugs screws. 20"x20"x2.5" | Each | 326.13 | 326.13 | 2.0 | False | None | None | False | None | False | 652.26 | 0 | 3210162 | 110481 | None | SR23-24,PWD,Elec,Vol-6,P-3,C-2,It.No-2.3.2,Pg5 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010. 1.5 mm2 | m | 26.0 | 26.0 | 100.0 | False | None | None | False | None | False | 2600.0 | 0 | 3210163 | 110481 | None | SR23-24,PWD,Elec,Vol-6,P-3,C-2,It.No-2.3.4,Pg5 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010. 4 mm2 | m | 63.0 | 63.0 | 35.0 | False | None | None | False | None | False | 2205.0 | 0 | 3210164 | 110481 | None | SR23-24,PWD,Elec,Vol-6,C-3,It.No-5.18.4,Pg17 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 Amps DP | Each | 739.0 | 739.0 | 1.0 | False | None | None | False | None | False | 739.0 | 0 | 3210165 | 110481 | None | SR23-24,PWD,Elec,Vol-6,P-3,C-5,It.No-5.30,Pg19 | Supplying, fixing and wiring electronic 5 to 20Amps single phase Class-1 Accuracy with Temper Proof Energy Meter. | Each | 1380.0 | 1380.0 | 1.0 | False | None | None | False | None | False | 1380.0 | 0 | 3210166 | 110481 | None | SR23-24,PWD,Elec,Vol-6,P-3,C-12,It.No-12.56,Pg54 | Supplying, fixing, wiring, earth electrode for grounding conduits, I.C.cutouts and other equipment's on the meter board using 40 mm dia 2.90 mm thick GI pipe 2.5m long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150 mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12 mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia | Each | 3510.0 | 3510.0 | 1.0 | False | None | None | False | None | False | 3510.0 | 0 | 3210167 | 110481 | None | KEB Deposit | 1 Room KEB Deposit | Each | 5155.0 | 5155.0 | 1.0 | False | None | None | False | None | False | 5155.0 | 0 |
|
|
---|