createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1717140241070
version2
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee5000.00
emd452000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose15-06-2024 17:00:00
tenderQueryClose10-06-2024 16:00:00
technicalBidOpen17-06-2024 11:00:00
publishedDate31-05-2024 13:37:00
publishedByPostGADCOCSS_CEO_GAD
publishedByUserKPE20333 - BASVARAJ YYALAGISHETTAR
bidValidityPeriod90
noOfCalls1
preBidMeetingDate10-06-2024 11:00:00
preBidMeetingYnTrue
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonBASVARAJ YYALAGISHETTAR
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedNone
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumberNone
mobileNumber9449514099
tenderSupplierListNone
tenderSchedule
createdTs1717140241090
version5
createdDateNone
modifiedDateNone
tenderNumberGADCOCSS/2024-25/BD/WORK_INDENT1
titleCONSTRUCTION OF THE GADAG CO-OPERATIVE COTTON SALES SOCIETY LTD ADMINISTRATIVE BLOCK AT GADAG
descriptionCONSTRUCTION OF THE GADAG CO-OPERATIVE COTTON SALES SOCIETY LTD ADMINISTRATIVE BLOCK AT GADAG
categoryWORKS
categoryTextWorks
ecv45162038.47
deptNameThe Gadag Co-Op cotton Sale Society Ltd
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnTrue
location10185
locationNameThe Gadag Co-Op cotton Sale Society Ltd Gadag
provisionalAmount53300000.0
groupOverheadTotal0.0
fileNumberGADCOCSS/ADM/BUL/2024/24/01
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17171402410000NoneNoneBuildingsCivil works of buildings42831714.9
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3209561110445Nonecode01Earth work in surface excavation by mechanical means for lowering & leveling the ground without blasting for all works other than foundation in Ordinary/ Soft rock & depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work In Ordinary/Soft rock upto 300 mm depthCum372.86372.86162.9FalseNoneNoneFalseNoneFalse60738.8940
3209562110445Nonecode02Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the workIn all kinds of soils Depth upto 3 m(Consider 30% Qty as Hard Soil)Cum105.06105.06146.59FalseNoneNoneFalseNoneFalse15400.74540
3209563110445Nonecode03Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the workIn In ordinary/soft rock without blasting upto 1.5 m depth(Consider 70% Qty In ordinary/soft rock without blasting)Cum373.89373.89342.05FalseNoneNoneFalseNoneFalse127889.07450
3209564110445Nonecode04Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications..Sqm121.54121.541440.44FalseNoneNoneFalseNoneFalse175071.07760
3209565110445Nonecode05Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm and down size graded crushed coarse aggregatesCum6168.676168.67270.38FalseNoneNoneFalseNoneFalse1667884.99460
3209566110445Nonecode06Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.(The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm and down size graded crushed coarse aggregatesCum6526.086526.08122.46FalseNoneNoneFalseNoneFalse799183.75680
3209567110445Nonecode07Additional for formwork,Centering and Scaffolding for SL No 6 foundation upto plinth isolated as per as per appendix-l in volume-1 of page No-111 @8% of finished workCum522.08522.08122.46FalseNoneNoneFalseNoneFalse63933.91680
3209568110445Nonecode08Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with :Cum6674.46674.499.43FalseNoneNoneFalseNoneFalse663635.5920
3209569110445Nonecode09Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works &other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.(The cost of steel reinforcement & fromwork to be paid separately) M25 Design Mix Using 20 mm and down size graded crushed coarse aggregates (PLINTHBEAM)Cum6526.086526.0836.92FalseNoneNoneFalseNoneFalse240942.87360
3209570110445Nonecode10Additional for formwork,Centering and Scaffolding for SL No 10 Plinth Beams of Buildings as per as per appendix-l in volume-1 of page No-111 @50% of finished workCum3263.043263.0436.92FalseNoneNoneFalseNoneFalse120471.43680
3209571110445Nonecode11Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum273.98273.981940.51FalseNoneNoneFalseNoneFalse531660.92980
3209572110445Nonecode12Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm and down size graded crushed coarse aggregates COLUMN UPTO PLITH BEAMCum7048.297048.2920.23FalseNoneNoneFalseNoneFalse142586.90670
3209573110445Nonecode13Additional for formwork,Centering and Scaffolding for SL No 13 RCC Columns / Shaft (Slip Centering)as per as per appendix-l in volume-1 of page No-111 @70% of finished workCum4933.84933.820.23FalseNoneNoneFalseNoneFalse99810.7740
3209574110445Nonecode14Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm and down size graded crushed coarse aggregates GROUND FLOOR RCC column,lintel,roof beam, slab,chajja ,staircaseCum7048.297048.29442.34FalseNoneNoneFalseNoneFalse3117740.59860
3209575110445Nonecode15Additional for formwork,Centering and Scaffolding for SL No 13 RCC Columns / Shaft (Slip Centering)as per as per appendix-l in volume-1 of page No-111 @70% of finished workCum4933.84933.867.15FalseNoneNoneFalseNoneFalse331304.670
3209576110445Nonecode16Additional for formwork,Centering and Scaffolding for SL No 13 RCC Beams, Lintels & Troughs of Aqueducts as per as per appendix-l in volume-1 of page No-111 @60% of finished workCum4228.974228.9712.47FalseNoneNoneFalseNoneFalse52735.25590
3209577110445Nonecode17Additional for formwork,Centering and Scaffolding for SL No 13 RCC Beams, Lintels & Troughs of Aqueducts as per as per appendix-l in volume-1 of page No-111 @60% of finished workCum4228.974228.9777.93FalseNoneNoneFalseNoneFalse329563.63210
3209578110445Nonecode18Additional for formwork,Centering and Scaffolding for SL No 13 RCC Roof Slabs as per as per appendix-l in volume-1 of page No-111 @50% of finished workCum3524.143524.14265.23FalseNoneNoneFalseNoneFalse934707.65220
3209579110445Nonecode19Additional for formwork,Centering and Scaffolding for SL No 13 Chejjas, Canopy & Other Architectural projections of minor sections as per as per appendix-l in volume-1 of page No-111 @45% of finished workCum3171.733171.733.77FalseNoneNoneFalseNoneFalse11957.42210
3209580110445Nonecode20Additional for formwork,Centering and Scaffolding for SL No 13 Chejjas, Canopy & Other Architectural projections of minor sections as per as per appendix-l in volume-1 of page No-111 @45% of finished workCum3171.733171.7315.77FalseNoneNoneFalseNoneFalse50018.18210
3209581110445Nonecode21Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm and down size graded crushed coarse aggregates FIRST FLOOR RCC COLUMN,LINTEL,ROOF BEAM,SLABCum7118.777118.77390.8025FalseNoneNoneFalseNoneFalse2782033.1129250
3209582110445Nonecode22Additional for formwork,Centering and Scaffolding for SL No 13 RCC Columns / Shaft (Slip Centering)as per as per appendix-l in volume-1 of page No-111 @70% of finished workCum4983.144983.1472.57FalseNoneNoneFalseNoneFalse361626.46980
3209583110445Nonecode23Additional for formwork,Centering and Scaffolding for SL No 13 RCC Beams, Lintels & Troughs of Aqueducts as per as per appendix-l in volume-1 of page No-111 @60% of finished workCum4271.264271.2611.71FalseNoneNoneFalseNoneFalse50016.45460
3209584110445Nonecode24Additional for formwork,Centering and Scaffolding for SL No 13 RCC Beams, Lintels & Troughs of Aqueducts as per as per appendix-l in volume-1 of page No-111 @60% of finished workCum4271.264271.2660.24FalseNoneNoneFalseNoneFalse257300.70240
3209585110445Nonecode25Additional for formwork,Centering and Scaffolding for SL No 13 RCC Roof Slabs as per as per appendix-l in volume-1 of page No-111 @50% of finished workCum3559.383559.38246.26FalseNoneNoneFalseNoneFalse876532.91880
3209586110445Nonecode26Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 20 mm and down size graded crushed coarse aggregates GROUND FLOOR CILLCum6403.516403.516.23FalseNoneNoneFalseNoneFalse39893.86730
3209587110445Nonecode27Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 20 mm and down size graded crushed coarse aggregates FIRST FLOOR For CILLCum6467.546467.545.85FalseNoneNoneFalseNoneFalse37835.1090
3209588110445Nonecode28Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification BUILDING GROUND FLOORTonne92140.7192140.7164.22FalseNoneNoneFalseNoneFalse5917276.39620
3209589110445Nonecode29Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification BUILDING FIRST FLOORTonne93062.1193062.1143.8FalseNoneNoneFalseNoneFalse4076120.4180
3209590110445Nonecode30Providing and constructing load bearing wall with Solid Concrete blocksof size 400x200x200mm having block density more than 1800kg/m3and minimum compressive strength of 4.00 N/mm2 conforming to IS2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005including cost of all materials, labour, scaffolding and curing, usagecharges of machinery etc complete as per specifications. GROUND FLOORSqm1349.31349.31555.27FalseNoneNoneFalseNoneFalse2098525.8110
3209591110445Nonecode31Providing and constructing load bearing wall with Solid Concrete blocksof size 400x200x200mm having block density more than 1800kg/m3and minimum compressive strength of 4.00 N/mm2 conforming to IS2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005including cost of all materials, labour, scaffolding and curing, usagecharges of machinery etc complete as per specifications. FIRST FLOORSqm1362.791362.791538.97FalseNoneNoneFalseNoneFalse2097292.92630
3209592110445Nonecode32Providing and fixing M.S. grills of required pattern in frames of windows weighing 21kg/M2 with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings/wooden frames with rawal plungs screwa etc (Qty (B)=9.5.00x21.00 Kg/M2) GROUND FLOOR M.S. grill workKg188.49188.492277.45FalseNoneNoneFalseNoneFalse429276.55050
3209593110445Nonecode33Providing and fixing M.S. grills of required pattern in frames of windows weighing 21kg/M2 with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings/wooden frames with rawal plungs screwa etc (Qty (B)=9.5.00x21.00 Kg/M2) FIRST FLOOR M.S GRILL WORKKg190.37190.372903.985FalseNoneNoneFalseNoneFalse552831.624450
3209594110445Nonecode34Providing Mathi/Nandi wood frames of doors, windows, clerestor windows, ventilators and other frames, wrought, framed or assembled including making plaster groves ( excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications. GROUND FLOORCum127928.06127928.061.101FalseNoneNoneFalseNoneFalse140848.794060
3209595110445Nonecode35Providing Mathi/Nandi wood frames of doors, windows, clerestor windows, ventilators and other frames, wrought, framed or assembled including making plaster groves ( excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications. FIRST FLOORCum129207.34129207.341.12FalseNoneNoneFalseNoneFalse144712.22080
3209596110445Nonecode36Providing and fixing flush door shutter made out of solid core block boardtype, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 30 mm thick Both side teak GROUND FLLORSqm4164.294164.2928.08FalseNoneNoneFalseNoneFalse116933.26320
3209597110445Nonecode37Providing and fixing flush door shutter made out of solid core block boardtype, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 30 mm thick Both side teak FIRST FLOORSqm4205.934205.9330.24FalseNoneNoneFalseNoneFalse127187.32320
3209598110445Nonecode38Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 5x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges. do- with both side prelam GROUND FLOORSqm2436.982436.984.72FalseNoneNoneFalseNoneFalse11502.54560
3209599110445Nonecode39Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 5x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges. do- with both side prelam FIRST FLOORSqm2436.982436.9811.02FalseNoneNoneFalseNoneFalse26855.51960
3209600110445Nonecode40Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mmCoextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi pointlocking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm.Maximum possible size -2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&Ps shall not be made) GROUND FLOORSqm6936.026936.0282.8FalseNoneNoneFalseNoneFalse574302.4560
3209601110445Nonecode41Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size -2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) FIRST FLOORSqm7005.387005.38105.75FalseNoneNoneFalseNoneFalse740818.9350
3209602110445Nonecode42Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size - 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) GROUND FLOORSqm5890.575890.5725.65FalseNoneNoneFalseNoneFalse151093.12050
3209603110445Nonecode43Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size -1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) FIRST FLOORSqm5949.475949.4732.53FalseNoneNoneFalseNoneFalse193536.25910
3209604110445Nonecode44Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. TOTAL(5.5KG/M2) GROUND FLOORKg581.95581.9592.4FalseNoneNoneFalseNoneFalse53772.180
3209605110445Nonecode45Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. TOTAL(5.5KG/M2) FIRST FLOORKg587.76587.7692.4FalseNoneNoneFalseNoneFalse54309.0240
3209606110445Nonecode46Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6 kg/m2 to achieve final DFT (Dry Film Thickness) of 1mm including prime coat of epoxy primer @150 g/m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification. TERRACESqm849.92849.921852.52FalseNoneNoneFalseNoneFalse1574493.79840
3209607110445Nonecode47Providing and fixing of prepigmented extruded orange cement roof tiles of size 420mm x 330mm with necessary specials such as Ridges , barges and nails etc including cost of providing PVC (6.00 kg/cm2) gutters of min 6" radius and down water pipes of 4" dia as per roof design on Existing Concrete Sloping Roof Slab. Including cost of mortar band, all materials labour as per specificationsSqm719.97719.971852.52FalseNoneNoneFalseNoneFalse1333758.82440
3209608110445Nonecode48Providing and supplying 'Acoustical Wall Paneling' with square edges made of fibre glass substrate 25mm thick and wrapped on the front side with an acoustically transparent and classified for Fire reaction Class A, as per ASTM E-84, fabric with option of colors - as per the choice of the Architect/Engineer incharge of the size 600x600mm, 600x1200mm & 600x1800mm providing a minimum sound absorption level of 0.85 NRC to be affixed to wall using Wall panel lmpaler sand construction adhesives as per the instructions laid down by the certified manufacturer. auditoriumSqm5898.815898.81100.0FalseNoneNoneFalseNoneFalse589881.00
3209609110445Nonecode49Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOOR ALL AROUND Out side PlasteringSqm364.62364.62892.88FalseNoneNoneFalseNoneFalse325561.90560
3209610110445Nonecode50Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. FIRST FLOOR ALL AROUND Out side PlasteringSqm368.26368.26698.79FalseNoneNoneFalseNoneFalse257336.40540
3209611110445Nonecode51Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOOR INSIDE WALLPlasteringSqm364.62364.621545.07FalseNoneNoneFalseNoneFalse563363.42340
3209612110445Nonecode52Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. FIRST FLOOR INSIDE WALLPlasteringSqm368.26368.261046.23FalseNoneNoneFalseNoneFalse385284.65980
3209613110445Nonecode53Providing 12 mm cement plaster with cement mortar 1:3 (1 cement: 3 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOOR SLAB PLASTERINGSqm332.69332.691465.07FalseNoneNoneFalseNoneFalse487414.13830
3209614110445Nonecode54Providing 12 mm cement plaster with cement mortar 1:3 (1 cement: 3 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. FIRST FLOOR SLAB PLASTERINGSqm336.01336.01727.79FalseNoneNoneFalseNoneFalse244544.71790
3209615110445Nonecode55Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOOR QTY AS PER TILE DADOINGSqm303.85303.8573.17FalseNoneNoneFalseNoneFalse22232.70450
3209616110445Nonecode56Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. FIRST FLOOR QTY AS PER TILE DADOINGSqm306.88306.8879.75FalseNoneNoneFalseNoneFalse24473.680
3209617110445Nonecode57Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. GROUND FLOORSqm103.0103.03010.14FalseNoneNoneFalseNoneFalse310044.420
3209618110445Nonecode58Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. FIRST FLOORSqm104.03104.031774.02FalseNoneNoneFalseNoneFalse184551.30060
3209619110445Nonecode59Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink,or equivalent. GROUND FLOORSqm2937.562937.56188.76FalseNoneNoneFalseNoneFalse554493.82560
3209620110445Nonecode60Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink,or equivalent. FIRST FLOORSqm2966.932966.93182.73FalseNoneNoneFalseNoneFalse542147.11890
3209621110445Nonecode61Providing and laying Polished Glazed Vitrified tiles in floor with different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based \ high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). Size of Tile 600x600 mm GROUND FLOORSqm1365.781365.781304.06FalseNoneNoneFalseNoneFalse1781059.06680
3209622110445Nonecode62Providing and laying Polished Glazed Vitrified tiles in floor with different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based \ high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). Size of Tile 600x600 mm FIRST FLOORSqm1379.431379.43577.15FalseNoneNoneFalseNoneFalse796138.02450
3209623110445Nonecode63Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. GROULD FLOORSqm1492.471492.4773.17FalseNoneNoneFalseNoneFalse109204.02990
3209624110445Nonecode64Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. FIRST FLOORSqm1507.391507.3979.75FalseNoneNoneFalseNoneFalse120214.35250
3209625110445Nonecode65Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre as per specifications and as per directions of Engineer in charge GROUND FLOORSqm113.3113.33010.14FalseNoneNoneFalseNoneFalse341048.8620
3209626110445Nonecode66Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre as per specifications and as per directions of Engineer in charge FIRST FLOORSqm114.43114.431774.02FalseNoneNoneFalseNoneFalse203001.10860
3209627110445Nonecode67Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre as per specifications and as per directions of Engineer in charge GROUND FLOORSqm54.5954.593010.14FalseNoneNoneFalseNoneFalse164323.54260
3209628110445Nonecode68Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre as per specifications and as per directions of Engineer in charge FIRST FLOORSqm55.1355.131774.02FalseNoneNoneFalseNoneFalse97801.72260
3209629110445Nonecode69Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOOR 75% OF TOTAL QTYSqm160.68160.68669.66FalseNoneNoneFalseNoneFalse107600.96880
3209630110445Nonecode70Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. FIRST FLOOR 75% OF TOTAL QTYSqm162.28162.28440.63FalseNoneNoneFalseNoneFalse71505.43640
3209631110445Nonecode71Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOOR Qty as per out side plaster 25% OF TOTAL QTYSqm291.49291.49223.22FalseNoneNoneFalseNoneFalse65066.39780
3209632110445Nonecode72Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. FIRST FLOOR Qty as per out side plaster 25% OF TOTAL QTYSqm294.4294.4146.87FalseNoneNoneFalseNoneFalse43238.5280
3209633110445Nonecode73Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/ litre as per specifications and as per directions of Engineer in charge. GROUND FLOORSqm57.6857.6857.8025FalseNoneNoneFalseNoneFalse3334.04820
3209634110445Nonecode74Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/ litre as per specifications and as per directions of Engineer in charge. FIRST FLOORSqm58.2558.2559.21FalseNoneNoneFalseNoneFalse3448.98250
3209635110445Nonecode75Painting with synthetic enamel paint of approved brand and manu facture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOOR as per grill area(2 sides), door frameSqm118.45118.45242.59FalseNoneNoneFalseNoneFalse28734.78550
3209636110445Nonecode76Painting with synthetic enamel paint of approved brand and manu facture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. FIRST FLOOR as per grill area(2 sides), door frameSqm119.63119.63302.89FalseNoneNoneFalseNoneFalse36234.73070
3209637110445Nonecode77Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finish ing the groove complete as per specifications and direction of the Engineer-in-charge: 20 mm to 25 mm wide to required depth. elevational groovesm52.5352.53200.0FalseNoneNoneFalseNoneFalse10506.00
17171402410000NoneNoneBuildingsWater Supply, Sanitary And Internal Electrification2330323.57
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3209638110446Nonecode78WATER SUPPLY AND SANITARY PART-A: SANITARY FIXTURES AND CP FITTINGS. Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required W.C. pan with ISI marked white solid plastic seat and lidEach6156.316156.319.0FalseNoneNoneFalseNoneFalse55406.790
3209639110446Nonecode79Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device(handle lever) conforming to IS:7231,with all fittings and fixtures complete, including cutting and making good the walls andfloors wherever required White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot restsEach5030.525030.521.0FalseNoneNoneFalseNoneFalse5030.520
3209640110446Nonecode80Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar tapsEach3174.463174.4612.0FalseNoneNoneFalseNoneFalse38093.520
3209641110446Nonecode81Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required 510x1040 mm bowl depth 250 mmEach5786.545786.542.0FalseNoneNoneFalseNoneFalse11573.080
3209642110446Nonecode82Providing and fixing C.P. brass bib cock of approved quality conform ing to IS:8931 TOILETSEach654.05654.0512.0FalseNoneNoneFalseNoneFalse7848.60
3209643110446Nonecode83Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931Each638.6638.618.0FalseNoneNoneFalseNoneFalse11494.80
3209644110446Nonecode84Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm or 340x410x265 mm sizes respectivelyEach1188.621188.629.0FalseNoneNoneFalseNoneFalse10697.580
3209645110446Nonecode85Providing and fixing Bidet spray made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete - Class Premium (HEALTH FAUCET)Each1050.61050.610.0FalseNoneNoneFalseNoneFalse10506.00
3209646110446Nonecode86PART:B CPVC / GI PIPES AND FITTNGS (INTERNAL AND EXTERNAL WATERSUPPLY) Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: (PVC pipes 25mm dia, 10 kg/sqcm & class 5)m49.4449.44250.0FalseNoneNoneFalseNoneFalse12360.00
3209647110446Nonecode87PVC pipes 32mm dia., 10 kg/sqcm & class 5m69.0169.01250.0FalseNoneNoneFalseNoneFalse17252.50
3209648110446Nonecode88Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete 20 mm nominal boreEach323.42323.4210.0FalseNoneNoneFalseNoneFalse3234.20
3209649110446Nonecode89Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete 25 mm nominal boreEach341.96341.9610.0FalseNoneNoneFalseNoneFalse3419.60
3209650110446Nonecode90Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) 32MM NOMINAL BOREEach615.94615.9410.0FalseNoneNoneFalseNoneFalse6159.40
3209651110446Nonecode91Constructing brick masonry chamber of internal dimension 600x450mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.Nos4934.734934.7350.0FalseNoneNoneFalseNoneFalse246736.50
3209652110446Nonecode92Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.Nos9.279.2730000.0FalseNoneNoneFalseNoneFalse278100.00
3209653110446Nonecode93PART:C PVC SOIL, WASTE VENT PIPE & FITTINGS (INTERNAL AND EXTERNAL DRAINAGE SYSTEM) Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: PVC pipes 75mm dia., 6 kg/sqcm & class 3m226.6226.6150.0FalseNoneNoneFalseNoneFalse33990.00
3209654110446Nonecode94Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: PVC pipes 110mm dia., 6 kg/sqcm & class 3m423.33423.33250.0FalseNoneNoneFalseNoneFalse105832.50
3209655110446Nonecode95Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: PVC pipes 160mm dia., 6 kg/sqcm & class 3m636.54636.5480.0FalseNoneNoneFalseNoneFalse50923.20
3209656110446Nonecode96Constructing brick masonry chamber of internal dimension 450x450mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover..No4363.084363.0811.0FalseNoneNoneFalseNoneFalse47993.880
3209657110446Nonecode97Constructing brick masonry chamber of internal dimension 600x450mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.No4934.734934.735.0FalseNoneNoneFalseNoneFalse24673.650
3209658110446Nonecode98Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work. In all kinds of soils. Depth upto 1.50mCum4988.294988.2925.0FalseNoneNoneFalseNoneFalse124707.250
3209659110446Nonecode99POINT WIRING USING COPPER WIRE WITHOUT SWITCH Supplying and wiring adopting loop system in the existing PVC conduit/casing capping using 1100V grade, copper conductor flexible multistrand FRLS PVC insulated multistrand 2 x 1.5 sq.mm cable confirming to the GTP, without switch, the other end of the wires shall be terminated with sufficient loose length in a PVC round block , complete for each outlet. point wiring using class A Materials Short point upto 3 mts from tapping point to out let via switchPoint269.0269.0400.0FalseNoneNoneFalseNoneFalse107600.00
3209660110446Nonecode100Medium point above 3 mts upto 6mts from tapping point to outlet via switchPoint379.0379.0250.0FalseNoneNoneFalseNoneFalse94750.00
3209661110446Nonecode101Long point above 6 mts upto 10 mts from tapping point to outlet via switchPoint555.0555.0250.0FalseNoneNoneFalseNoneFalse138750.00
3209662110446Nonecode102Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 1 - 3WayEach159.0159.0150.0FalseNoneNoneFalseNoneFalse23850.00
3209663110446Nonecode103Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 4 - 5WayEach177.0177.0150.0FalseNoneNoneFalseNoneFalse26550.00
3209664110446Nonecode104Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 6 WayEach220.0220.0125.0FalseNoneNoneFalseNoneFalse27500.00
3209665110446Nonecode105Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 8 WayEach261.0261.0150.0FalseNoneNoneFalseNoneFalse39150.00
3209666110446Nonecode106Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 10 / 12 WayEach319.0319.075.0FalseNoneNoneFalseNoneFalse23925.00
3209667110446Nonecode107Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 1 to 3 ModuleEach152.0152.0150.0FalseNoneNoneFalseNoneFalse22800.00
3209668110446Nonecode108Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 4 ModuleEach175.0175.0150.0FalseNoneNoneFalseNoneFalse26250.00
3209669110446Nonecode109Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 6 ModuleEach234.0234.0175.0FalseNoneNoneFalseNoneFalse40950.00
3209670110446Nonecode110Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 8 ModuleEach284.0284.080.0FalseNoneNoneFalseNoneFalse22720.00
3209671110446Nonecode111Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 12 ModuleEach344.0344.080.0FalseNoneNoneFalseNoneFalse27520.00
3209672110446Nonecode112Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6 amps one way switchEach102.0102.0400.0FalseNoneNoneFalseNoneFalse40800.00
3209673110446Nonecode113Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6 amps two way switchEach166.0166.0400.0FalseNoneNoneFalseNoneFalse66400.00
3209674110446Nonecode114Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6 Amps 3 way socketsEach171.0171.050.0FalseNoneNoneFalseNoneFalse8550.00
3209675110446Nonecode115Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 stepped fan Regulator'sEach357.0357.0180.0FalseNoneNoneFalseNoneFalse64260.00
3209676110446Nonecode116Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6/16 Amps universal socketsEach236.0236.050.0FalseNoneNoneFalseNoneFalse11800.00
3209677110446Nonecode117Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 16A one way switchEach236.0236.050.0FalseNoneNoneFalseNoneFalse11800.00
3209678110446Nonecode118Supplying and fixing M.S.Rafter clamp set made out of M.S flat & 14mm M.S.rodEach160.0160.0180.0FalseNoneNoneFalseNoneFalse28800.00
3209679110446Nonecode119Supply and fixing one metal Fan box with round hookEach117.0117.0180.0FalseNoneNoneFalseNoneFalse21060.00
3209680110446Nonecode120Concealed Conduit System Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary 20 mm diaMtr66.066.0400.0FalseNoneNoneFalseNoneFalse26400.00
3209681110446Nonecode121Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary 25 mm diaMtr78.078.0300.0FalseNoneNoneFalseNoneFalse23400.00
3209682110446Nonecode122Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary 32 mm diaMtr103.0103.0200.0FalseNoneNoneFalseNoneFalse20600.00
3209683110446Nonecode123Groove Cutting in Wall Supplying 2 mm thick heavy gauge PVC conduit pipe with bends metal junction boxes adhesives paste etc and bracing U or J hooks and cement plastering upto the surface of the trick level and run with 18 SWG Gi fish wire run through out the conduit wherever necessary 20 mm diaMtr68.068.0400.0FalseNoneNoneFalseNoneFalse27200.00
3209684110446Nonecode124Supplying 2 mm thick heavy gauge PVC conduit pipe with bends metal junction boxes adhesives paste etc and bracing U or J hooks and cement plastering upto the surface of the trick level and run with 18 SWG Gi fish wire run through out the conduit wherever necessary 25 mm diaMtr79.079.0300.0FalseNoneNoneFalseNoneFalse23700.00
3209685110446Nonecode125Supplying 2 mm thick heavy gauge PVC conduit pipe with bends metal junction boxes adhesives paste etc and bracing U or J hooks and cement plastering upto the surface of the trick level and run with 18 SWG Gi fish wire run through out the conduit wherever necessary 32 mm diaMtr99.099.0200.0FalseNoneNoneFalseNoneFalse19800.00
3209686110446Nonecode126Supplying and fixing PVC/metal conduit deep junction box. 19/20mm deep junction boxMtr49.049.0100.0FalseNoneNoneFalseNoneFalse4900.00
3209687110446Nonecode127Supplying and fixing PVC/metal conduit deep junction box. 25mm deep junction boxEach56.056.050.0FalseNoneNoneFalseNoneFalse2800.00
3209688110446Nonecode128WIRING FOR Lighting/Power Circuits FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to GTP 1.5 Sq.mmMtr26.026.0500.0FalseNoneNoneFalseNoneFalse13000.00
3209689110446Nonecode129FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to GTP 2.5 sq.mmMtr42.042.0400.0FalseNoneNoneFalseNoneFalse16800.00
3209690110446Nonecode130FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to GTP 4 sq.mmMtr63.063.0300.0FalseNoneNoneFalseNoneFalse18900.00
3209691110446Nonecode131FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to GTP 6sq.mmMtr92.092.0250.0FalseNoneNoneFalseNoneFalse23000.00
3209692110446Nonecode132FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to GTP 10sq.mmMtr167.0167.0200.0FalseNoneNoneFalseNoneFalse33400.00
3209693110446Nonecode133Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 1.5 sq.mmEach3.03.0400.0FalseNoneNoneFalseNoneFalse1200.00
3209694110446Nonecode134Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 2.5 sq.mmEach4.04.0300.0FalseNoneNoneFalseNoneFalse1200.00
3209695110446Nonecode135Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 4 sq.mmEach7.07.0350.0FalseNoneNoneFalseNoneFalse2450.00
3209696110446Nonecode136Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 6 sq.mmEach7.07.0300.0FalseNoneNoneFalseNoneFalse2100.00
3209697110446Nonecode137Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 10 sq.mmEach8.08.0250.0FalseNoneNoneFalseNoneFalse2000.00
3209698110446Nonecode138Supplying and fixing regular MCB distribution boards on wall/ oodboard/ flush mounting using required clamps ,bolts, nutsetc., with provision for fixing suitable type capacity MCB's single phase /3phase /singledoor with powdercoated painting Made out of 14 SWGMS enclosure. II - Double Door 4Way TP & NEach1524.01524.015.0FalseNoneNoneFalseNoneFalse22860.00
3209699110446Nonecode139Supplying and fixing regular MCB distribution boards on wall/ oodboard/ flush mounting using required clamps ,bolts, nutsetc., with provision for fixing suitable type capacity MCB's single phase /3phase /singledoor with powdercoated painting Made out of 14 SWGMS enclosure. II - Double Door 8 Way SP & NEach1854.01854.010.0FalseNoneNoneFalseNoneFalse18540.00
3209700110446Nonecode140Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing material sand 'C' Type curve ,indicatorON/OFF ,energycross- 3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC60898. 6 to 32 Amps SPEach415.0415.025.0FalseNoneNoneFalseNoneFalse10375.00
3209701110446Nonecode141Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing material sand 'C' Type curve ,indicatorON/OFF ,energycross- 3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC60898. 6 to 32 Amps DPEach739.0739.015.0FalseNoneNoneFalseNoneFalse11085.00
3209702110446Nonecode142Supplying, fixing and wiring Residual current circuit breaker (RCCB)240/450V upto 300mA sensitivity on existing wood/ panel board. 32-40 Amps 2 poleEach4559.04559.05.0FalseNoneNoneFalseNoneFalse22795.00
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17171402420000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17171402420000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17171402420000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17171402420000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17171402420000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
17171402680000NoneNoneELIGIBILITYAll other terms and conditions as per tender documentNone
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneMinimum financial turnover (civil engineering construction works) not less than two times the annual payments from this contract (Rs. xxxxx Lakhs)NoneNone
NoneNoneNoneNoneSatisfactoriy completed (atleast 90%) as prime contractor at-least one such similar work of value not less than Rs. xxxxxxx (80% of estimated cost of tender)NoneNone
NoneNoneNoneNoneExecuted in any one year the following minimum quantities of work (Cement Concrete - xxxx cum, Earthwork - xxxx cum, etc) (80% of peak rate of construction)NoneNone
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid Electrical License for executing building electrificatio works and should have executed similar electrical works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid license for executing water supply / sanitary engineering works and should have executed similar works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneOwning the following key and critical equipment for this work (xxxx, xxxx, xxxx)NoneNone
NoneNoneNoneNoneLiquid assets and /or availability of credit facilities of no less than Rs. xxxxxx Lakhs (estimated cash flow for 3 months of peak construction period)NoneNone
NoneNoneNoneNoneTotal value of civl engineering works executed and payments received in the last five years (year-wise)NoneNone
NoneNoneNoneNoneList of existing commitments and ongoing worksNoneNone
NoneNoneNoneNoneList of works for which tenders already submittedNoneNone
NoneNoneNoneNoneBanker Details for referenceNoneNone
NoneNoneNoneNoneConstruction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneReports on the financial standing of the tenderer, such as profit and loss statements and auditor’s reports for the last five yearsNoneNone
NoneNoneNoneNoneQualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneList of Financial Resources with CertificatesNoneNone
NoneNoneNoneNoneWORK PERFORMED AS A PRIME CONTRACTOR (IN THE SAME NAME) OF MINIMUM RS. 226.00 LAKHS WORKS OF SIMILAR NATURE IN LAST FIVE YEARS.Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Annual Turnover CertificateTrueTechnical Bid
Company Registration CertificateTrueTechnical Bid
GST Registration CertificateTrueTechnical Bid
Valid PWD class-1 licenseTrueTechnical Bid
SITE VISIT CERTIFICATE SHOULD BE UPLOADED OBTAINED FROM CEO THE GADAG CO-OPERATIVE COTTON SALE SOCIETY LTD. GADAGTrueTechnical Bid
COPY OF FIVE YEARS INCOME TAX RETURNSTrueTechnical Bid
BIDDER SHOULD UPLOAD ALL DOCUMENTS AS MENTIONED IN SECTION ITrueTechnical Bid
tenderWorkLocationList
tenderAddress
createdTs1717141133000
version0
createdDateNone
modifiedDateNone
blockNumberOFFICE OF THE GADAG CO OPERATIVE COTTON SALES SOCIETY LTD GADAG
streetNone
cityGADAG
stateKarnataka
pin582101
tenderRecallDTONone