tenderSubEstimateList | createdTs | version | createdDate | modifiedDate | workCategoryName | subEstimateName | estimateTotal | itemList |
---|
1717140241000 | 0 | None | None | Buildings | Civil works of buildings | 42831714.9 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3209561 | 110445 | None | code01 | Earth work in surface excavation by mechanical means for lowering & leveling the ground without blasting for all works other than foundation in Ordinary/ Soft rock & depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5
m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work In Ordinary/Soft rock upto 300 mm depth | Cum | 372.86 | 372.86 | 162.9 | False | None | None | False | None | False | 60738.894 | 0 | 3209562 | 110445 | None | code02 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the workIn all kinds of soils Depth upto 3 m(Consider 30% Qty as Hard Soil) | Cum | 105.06 | 105.06 | 146.59 | False | None | None | False | None | False | 15400.7454 | 0 | 3209563 | 110445 | None | code03 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the workIn In ordinary/soft rock without blasting upto 1.5 m depth(Consider 70% Qty In ordinary/soft rock without blasting) | Cum | 373.89 | 373.89 | 342.05 | False | None | None | False | None | False | 127889.0745 | 0 | 3209564 | 110445 | None | code04 | Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications.. | Sqm | 121.54 | 121.54 | 1440.44 | False | None | None | False | None | False | 175071.0776 | 0 | 3209565 | 110445 | None | code05 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm and down size graded crushed coarse aggregates | Cum | 6168.67 | 6168.67 | 270.38 | False | None | None | False | None | False | 1667884.9946 | 0 | 3209566 | 110445 | None | code06 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.(The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm and down size graded crushed coarse
aggregates | Cum | 6526.08 | 6526.08 | 122.46 | False | None | None | False | None | False | 799183.7568 | 0 | 3209567 | 110445 | None | code07 | Additional for formwork,Centering and Scaffolding for SL No 6 foundation upto plinth isolated as per as per appendix-l in volume-1 of page No-111 @8% of finished work | Cum | 522.08 | 522.08 | 122.46 | False | None | None | False | None | False | 63933.9168 | 0 | 3209568 | 110445 | None | code08 | Providing Random rubble masonry with hard stone in foundation and
plinth including levelling up with cement concrete 1:6:12 (1 cement : 6
coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth
level with : | Cum | 6674.4 | 6674.4 | 99.43 | False | None | None | False | None | False | 663635.592 | 0 | 3209569 | 110445 | None | code09 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works &other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.(The cost of steel reinforcement & fromwork to be paid separately) M25 Design Mix Using 20 mm and down size graded crushed coarse aggregates (PLINTHBEAM) | Cum | 6526.08 | 6526.08 | 36.92 | False | None | None | False | None | False | 240942.8736 | 0 | 3209570 | 110445 | None | code10 | Additional for formwork,Centering and Scaffolding for SL No 10 Plinth Beams of Buildings as per as per appendix-l in volume-1 of page No-111 @50% of finished work | Cum | 3263.04 | 3263.04 | 36.92 | False | None | None | False | None | False | 120471.4368 | 0 | 3209571 | 110445 | None | code11 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | Cum | 273.98 | 273.98 | 1940.51 | False | None | None | False | None | False | 531660.9298 | 0 | 3209572 | 110445 | None | code12 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm and down size graded crushed coarse aggregates COLUMN UPTO PLITH BEAM | Cum | 7048.29 | 7048.29 | 20.23 | False | None | None | False | None | False | 142586.9067 | 0 | 3209573 | 110445 | None | code13 | Additional for formwork,Centering and Scaffolding for SL No 13 RCC Columns / Shaft (Slip Centering)as per as per appendix-l in volume-1 of page No-111 @70% of finished work | Cum | 4933.8 | 4933.8 | 20.23 | False | None | None | False | None | False | 99810.774 | 0 | 3209574 | 110445 | None | code14 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm and down size graded crushed coarse aggregates GROUND FLOOR RCC column,lintel,roof beam, slab,chajja ,staircase | Cum | 7048.29 | 7048.29 | 442.34 | False | None | None | False | None | False | 3117740.5986 | 0 | 3209575 | 110445 | None | code15 | Additional for formwork,Centering and Scaffolding for SL No 13 RCC Columns / Shaft (Slip Centering)as per as per appendix-l in volume-1 of page No-111 @70% of finished work | Cum | 4933.8 | 4933.8 | 67.15 | False | None | None | False | None | False | 331304.67 | 0 | 3209576 | 110445 | None | code16 | Additional for formwork,Centering and Scaffolding for SL No 13 RCC Beams, Lintels & Troughs of Aqueducts as per as per appendix-l in volume-1 of page No-111 @60% of finished work | Cum | 4228.97 | 4228.97 | 12.47 | False | None | None | False | None | False | 52735.2559 | 0 | 3209577 | 110445 | None | code17 | Additional for formwork,Centering and Scaffolding for SL No 13 RCC Beams, Lintels & Troughs of Aqueducts as per as per appendix-l in volume-1 of page No-111 @60% of finished work | Cum | 4228.97 | 4228.97 | 77.93 | False | None | None | False | None | False | 329563.6321 | 0 | 3209578 | 110445 | None | code18 | Additional for formwork,Centering and Scaffolding for SL No 13 RCC Roof Slabs as per as per appendix-l in volume-1 of page No-111 @50% of finished work | Cum | 3524.14 | 3524.14 | 265.23 | False | None | None | False | None | False | 934707.6522 | 0 | 3209579 | 110445 | None | code19 | Additional for formwork,Centering and Scaffolding for SL No 13 Chejjas, Canopy & Other Architectural projections of minor sections as per as per appendix-l in volume-1 of page No-111 @45% of finished work | Cum | 3171.73 | 3171.73 | 3.77 | False | None | None | False | None | False | 11957.4221 | 0 | 3209580 | 110445 | None | code20 | Additional for formwork,Centering and Scaffolding for SL No 13 Chejjas, Canopy & Other Architectural projections of minor sections as per as per appendix-l in volume-1 of page No-111 @45% of finished work | Cum | 3171.73 | 3171.73 | 15.77 | False | None | None | False | None | False | 50018.1821 | 0 | 3209581 | 110445 | None | code21 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm and down size graded crushed coarse aggregates FIRST FLOOR RCC COLUMN,LINTEL,ROOF BEAM,SLAB | Cum | 7118.77 | 7118.77 | 390.8025 | False | None | None | False | None | False | 2782033.112925 | 0 | 3209582 | 110445 | None | code22 | Additional for formwork,Centering and Scaffolding for SL No 13 RCC Columns / Shaft (Slip Centering)as per as per appendix-l in volume-1 of page No-111 @70% of finished work | Cum | 4983.14 | 4983.14 | 72.57 | False | None | None | False | None | False | 361626.4698 | 0 | 3209583 | 110445 | None | code23 | Additional for formwork,Centering and Scaffolding for SL No 13 RCC Beams, Lintels & Troughs of Aqueducts as per as per appendix-l in volume-1 of page No-111 @60% of finished work | Cum | 4271.26 | 4271.26 | 11.71 | False | None | None | False | None | False | 50016.4546 | 0 | 3209584 | 110445 | None | code24 | Additional for formwork,Centering and Scaffolding for SL No 13 RCC Beams, Lintels & Troughs of Aqueducts as per as per appendix-l in volume-1 of page No-111 @60% of finished work | Cum | 4271.26 | 4271.26 | 60.24 | False | None | None | False | None | False | 257300.7024 | 0 | 3209585 | 110445 | None | code25 | Additional for formwork,Centering and Scaffolding for SL No 13 RCC Roof Slabs as per as per appendix-l in volume-1 of page No-111 @50% of finished work | Cum | 3559.38 | 3559.38 | 246.26 | False | None | None | False | None | False | 876532.9188 | 0 | 3209586 | 110445 | None | code26 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 20 mm and down size graded crushed coarse aggregates GROUND FLOOR CILL | Cum | 6403.51 | 6403.51 | 6.23 | False | None | None | False | None | False | 39893.8673 | 0 | 3209587 | 110445 | None | code27 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 20 mm and down size graded crushed coarse aggregates FIRST FLOOR For CILL | Cum | 6467.54 | 6467.54 | 5.85 | False | None | None | False | None | False | 37835.109 | 0 | 3209588 | 110445 | None | code28 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement
including cost of all materials, machinery, labour, cleaning, straightening,
cutting, bending, hooking, laping/welding joints, tying with binding wire / soft
annealed steel wire and other ancilary operations complete as per drawing and
technical specification BUILDING GROUND FLOOR | Tonne | 92140.71 | 92140.71 | 64.22 | False | None | None | False | None | False | 5917276.3962 | 0 | 3209589 | 110445 | None | code29 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement
including cost of all materials, machinery, labour, cleaning, straightening,
cutting, bending, hooking, laping/welding joints, tying with binding wire / soft
annealed steel wire and other ancilary operations complete as per drawing and
technical specification BUILDING FIRST FLOOR | Tonne | 93062.11 | 93062.11 | 43.8 | False | None | None | False | None | False | 4076120.418 | 0 | 3209590 | 110445 | None | code30 | Providing and constructing load bearing wall with Solid Concrete blocksof size 400x200x200mm having block density more than 1800kg/m3and minimum compressive strength of 4.00 N/mm2 conforming to IS2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005including cost of all materials, labour, scaffolding and curing, usagecharges of machinery etc complete as per specifications. GROUND FLOOR | Sqm | 1349.3 | 1349.3 | 1555.27 | False | None | None | False | None | False | 2098525.811 | 0 | 3209591 | 110445 | None | code31 | Providing and constructing load bearing wall with Solid Concrete blocksof size 400x200x200mm having block density more than 1800kg/m3and minimum compressive strength of 4.00 N/mm2 conforming to IS2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005including cost of all materials, labour, scaffolding and curing, usagecharges of machinery etc complete as per specifications. FIRST FLOOR | Sqm | 1362.79 | 1362.79 | 1538.97 | False | None | None | False | None | False | 2097292.9263 | 0 | 3209592 | 110445 | None | code32 | Providing and fixing M.S. grills of required pattern in frames of windows weighing 21kg/M2 with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings/wooden frames with rawal plungs screwa etc (Qty (B)=9.5.00x21.00 Kg/M2) GROUND FLOOR M.S. grill work | Kg | 188.49 | 188.49 | 2277.45 | False | None | None | False | None | False | 429276.5505 | 0 | 3209593 | 110445 | None | code33 | Providing and fixing M.S. grills of required pattern in frames of windows weighing 21kg/M2 with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings/wooden frames with rawal plungs screwa etc (Qty (B)=9.5.00x21.00 Kg/M2) FIRST FLOOR M.S GRILL WORK | Kg | 190.37 | 190.37 | 2903.985 | False | None | None | False | None | False | 552831.62445 | 0 | 3209594 | 110445 | None | code34 | Providing Mathi/Nandi wood frames of doors, windows, clerestor windows, ventilators and other frames, wrought, framed or assembled including making plaster groves ( excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications. GROUND FLOOR | Cum | 127928.06 | 127928.06 | 1.101 | False | None | None | False | None | False | 140848.79406 | 0 | 3209595 | 110445 | None | code35 | Providing Mathi/Nandi wood frames of doors, windows, clerestor windows, ventilators and other frames, wrought, framed or assembled including making plaster groves ( excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications. FIRST FLOOR | Cum | 129207.34 | 129207.34 | 1.12 | False | None | None | False | None | False | 144712.2208 | 0 | 3209596 | 110445 | None | code36 | Providing and fixing flush door shutter made out of solid core block boardtype, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer
complete as per spcification. -do- 30 mm thick Both side teak GROUND FLLOR | Sqm | 4164.29 | 4164.29 | 28.08 | False | None | None | False | None | False | 116933.2632 | 0 | 3209597 | 110445 | None | code37 | Providing and fixing flush door shutter made out of solid core block boardtype, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer
complete as per spcification. -do- 30 mm thick Both side teak FIRST FLOOR | Sqm | 4205.93 | 4205.93 | 30.24 | False | None | None | False | None | False | 127187.3232 | 0 | 3209598 | 110445 | None | code38 | Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 5x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges. do- with both side prelam GROUND FLOOR | Sqm | 2436.98 | 2436.98 | 4.72 | False | None | None | False | None | False | 11502.5456 | 0 | 3209599 | 110445 | None | code39 | Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 5x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges. do- with both side prelam FIRST FLOOR | Sqm | 2436.98 | 2436.98 | 11.02 | False | None | None | False | None | False | 26855.5196 | 0 | 3209600 | 110445 | None | code40 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mmCoextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi pointlocking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm.Maximum possible size -2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&Ps shall not be made) GROUND FLOOR | Sqm | 6936.02 | 6936.02 | 82.8 | False | None | None | False | None | False | 574302.456 | 0 | 3209601 | 110445 | None | code41 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size -2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) FIRST FLOOR | Sqm | 7005.38 | 7005.38 | 105.75 | False | None | None | False | None | False | 740818.935 | 0 | 3209602 | 110445 | None | code42 | Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size - 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) GROUND FLOOR | Sqm | 5890.57 | 5890.57 | 25.65 | False | None | None | False | None | False | 151093.1205 | 0 | 3209603 | 110445 | None | code43 | Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size -1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) FIRST FLOOR | Sqm | 5949.47 | 5949.47 | 32.53 | False | None | None | False | None | False | 193536.2591 | 0 | 3209604 | 110445 | None | code44 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. TOTAL(5.5KG/M2) GROUND FLOOR | Kg | 581.95 | 581.95 | 92.4 | False | None | None | False | None | False | 53772.18 | 0 | 3209605 | 110445 | None | code45 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. TOTAL(5.5KG/M2) FIRST FLOOR | Kg | 587.76 | 587.76 | 92.4 | False | None | None | False | None | False | 54309.024 | 0 | 3209606 | 110445 | None | code46 | Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6 kg/m2 to achieve final DFT (Dry Film Thickness) of 1mm including prime coat of epoxy primer @150 g/m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification. TERRACE | Sqm | 849.92 | 849.92 | 1852.52 | False | None | None | False | None | False | 1574493.7984 | 0 | 3209607 | 110445 | None | code47 | Providing and fixing of prepigmented extruded orange cement roof tiles of size 420mm x 330mm with necessary specials such as Ridges , barges and nails etc including cost of providing PVC (6.00 kg/cm2) gutters of min 6" radius and down water pipes of 4" dia as per roof design on Existing Concrete Sloping Roof Slab. Including cost of mortar band, all materials labour as per specifications | Sqm | 719.97 | 719.97 | 1852.52 | False | None | None | False | None | False | 1333758.8244 | 0 | 3209608 | 110445 | None | code48 | Providing and supplying 'Acoustical Wall Paneling' with square edges made of fibre glass substrate 25mm thick and wrapped on the front side with an acoustically transparent and classified for Fire reaction Class A, as per ASTM E-84, fabric with option of colors - as per the choice of the Architect/Engineer incharge of the size 600x600mm, 600x1200mm & 600x1800mm providing a minimum sound absorption level of 0.85 NRC to be affixed to wall using Wall panel lmpaler sand construction adhesives as per the instructions laid down by the certified manufacturer. auditorium | Sqm | 5898.81 | 5898.81 | 100.0 | False | None | None | False | None | False | 589881.0 | 0 | 3209609 | 110445 | None | code49 | Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOOR ALL AROUND Out side Plastering | Sqm | 364.62 | 364.62 | 892.88 | False | None | None | False | None | False | 325561.9056 | 0 | 3209610 | 110445 | None | code50 | Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. FIRST FLOOR ALL AROUND Out side Plastering | Sqm | 368.26 | 368.26 | 698.79 | False | None | None | False | None | False | 257336.4054 | 0 | 3209611 | 110445 | None | code51 | Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOOR INSIDE WALLPlastering | Sqm | 364.62 | 364.62 | 1545.07 | False | None | None | False | None | False | 563363.4234 | 0 | 3209612 | 110445 | None | code52 | Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. FIRST FLOOR INSIDE WALLPlastering | Sqm | 368.26 | 368.26 | 1046.23 | False | None | None | False | None | False | 385284.6598 | 0 | 3209613 | 110445 | None | code53 | Providing 12 mm cement plaster with cement mortar 1:3 (1 cement: 3 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOOR SLAB PLASTERING | Sqm | 332.69 | 332.69 | 1465.07 | False | None | None | False | None | False | 487414.1383 | 0 | 3209614 | 110445 | None | code54 | Providing 12 mm cement plaster with cement mortar 1:3 (1 cement: 3 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. FIRST FLOOR SLAB PLASTERING | Sqm | 336.01 | 336.01 | 727.79 | False | None | None | False | None | False | 244544.7179 | 0 | 3209615 | 110445 | None | code55 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOOR QTY AS PER TILE DADOING | Sqm | 303.85 | 303.85 | 73.17 | False | None | None | False | None | False | 22232.7045 | 0 | 3209616 | 110445 | None | code56 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. FIRST FLOOR QTY AS PER TILE DADOING | Sqm | 306.88 | 306.88 | 79.75 | False | None | None | False | None | False | 24473.68 | 0 | 3209617 | 110445 | None | code57 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. GROUND FLOOR | Sqm | 103.0 | 103.0 | 3010.14 | False | None | None | False | None | False | 310044.42 | 0 | 3209618 | 110445 | None | code58 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. FIRST FLOOR | Sqm | 104.03 | 104.03 | 1774.02 | False | None | None | False | None | False | 184551.3006 | 0 | 3209619 | 110445 | None | code59 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink,or equivalent. GROUND FLOOR | Sqm | 2937.56 | 2937.56 | 188.76 | False | None | None | False | None | False | 554493.8256 | 0 | 3209620 | 110445 | None | code60 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink,or equivalent. FIRST FLOOR | Sqm | 2966.93 | 2966.93 | 182.73 | False | None | None | False | None | False | 542147.1189 | 0 | 3209621 | 110445 | None | code61 | Providing and laying Polished Glazed Vitrified tiles in floor with different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based \ high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). Size of Tile 600x600 mm GROUND FLOOR | Sqm | 1365.78 | 1365.78 | 1304.06 | False | None | None | False | None | False | 1781059.0668 | 0 | 3209622 | 110445 | None | code62 | Providing and laying Polished Glazed Vitrified tiles in floor with different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based \ high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). Size of Tile 600x600 mm FIRST FLOOR | Sqm | 1379.43 | 1379.43 | 577.15 | False | None | None | False | None | False | 796138.0245 | 0 | 3209623 | 110445 | None | code63 | Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. GROULD FLOOR | Sqm | 1492.47 | 1492.47 | 73.17 | False | None | None | False | None | False | 109204.0299 | 0 | 3209624 | 110445 | None | code64 | Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. FIRST FLOOR | Sqm | 1507.39 | 1507.39 | 79.75 | False | None | None | False | None | False | 120214.3525 | 0 | 3209625 | 110445 | None | code65 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre as per specifications and as per directions of Engineer in charge GROUND FLOOR | Sqm | 113.3 | 113.3 | 3010.14 | False | None | None | False | None | False | 341048.862 | 0 | 3209626 | 110445 | None | code66 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre as per specifications and as per directions of Engineer in charge FIRST FLOOR | Sqm | 114.43 | 114.43 | 1774.02 | False | None | None | False | None | False | 203001.1086 | 0 | 3209627 | 110445 | None | code67 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre as per specifications and as per directions of Engineer in charge GROUND FLOOR | Sqm | 54.59 | 54.59 | 3010.14 | False | None | None | False | None | False | 164323.5426 | 0 | 3209628 | 110445 | None | code68 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre as per specifications and as per directions of Engineer in charge FIRST FLOOR | Sqm | 55.13 | 55.13 | 1774.02 | False | None | None | False | None | False | 97801.7226 | 0 | 3209629 | 110445 | None | code69 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOOR 75% OF TOTAL QTY | Sqm | 160.68 | 160.68 | 669.66 | False | None | None | False | None | False | 107600.9688 | 0 | 3209630 | 110445 | None | code70 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. FIRST FLOOR 75% OF TOTAL QTY | Sqm | 162.28 | 162.28 | 440.63 | False | None | None | False | None | False | 71505.4364 | 0 | 3209631 | 110445 | None | code71 | Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOOR Qty as per out side plaster 25% OF TOTAL QTY | Sqm | 291.49 | 291.49 | 223.22 | False | None | None | False | None | False | 65066.3978 | 0 | 3209632 | 110445 | None | code72 | Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. FIRST FLOOR Qty as per out side plaster 25% OF TOTAL QTY | Sqm | 294.4 | 294.4 | 146.87 | False | None | None | False | None | False | 43238.528 | 0 | 3209633 | 110445 | None | code73 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/ litre as per specifications and as per directions of Engineer in charge. GROUND FLOOR | Sqm | 57.68 | 57.68 | 57.8025 | False | None | None | False | None | False | 3334.0482 | 0 | 3209634 | 110445 | None | code74 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/ litre as per specifications and as per directions of Engineer in charge. FIRST FLOOR | Sqm | 58.25 | 58.25 | 59.21 | False | None | None | False | None | False | 3448.9825 | 0 | 3209635 | 110445 | None | code75 | Painting with synthetic enamel paint of approved brand and manu facture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOOR as per grill area(2 sides), door frame | Sqm | 118.45 | 118.45 | 242.59 | False | None | None | False | None | False | 28734.7855 | 0 | 3209636 | 110445 | None | code76 | Painting with synthetic enamel paint of approved brand and manu facture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. FIRST FLOOR as per grill area(2 sides), door frame | Sqm | 119.63 | 119.63 | 302.89 | False | None | None | False | None | False | 36234.7307 | 0 | 3209637 | 110445 | None | code77 | Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finish ing the groove complete as per specifications and direction of the Engineer-in-charge: 20 mm to 25 mm wide to required depth. elevational grooves | m | 52.53 | 52.53 | 200.0 | False | None | None | False | None | False | 10506.0 | 0 |
| 1717140241000 | 0 | None | None | Buildings | Water Supply, Sanitary And Internal Electrification | 2330323.57 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3209638 | 110446 | None | code78 | WATER SUPPLY AND SANITARY PART-A: SANITARY FIXTURES AND CP FITTINGS. Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required W.C. pan with ISI marked white solid plastic seat and lid | Each | 6156.31 | 6156.31 | 9.0 | False | None | None | False | None | False | 55406.79 | 0 | 3209639 | 110446 | None | code79 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device(handle lever) conforming to IS:7231,with all fittings and fixtures complete, including cutting and making good the walls andfloors wherever required White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests | Each | 5030.52 | 5030.52 | 1.0 | False | None | None | False | None | False | 5030.52 | 0 | 3209640 | 110446 | None | code80 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require White Vitreous China Wash basin size 630x450 mm with a pair of 15
mm C.P. brass pillar taps | Each | 3174.46 | 3174.46 | 12.0 | False | None | None | False | None | False | 38093.52 | 0 | 3209641 | 110446 | None | code81 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required 510x1040 mm bowl depth 250 mm | Each | 5786.54 | 5786.54 | 2.0 | False | None | None | False | None | False | 11573.08 | 0 | 3209642 | 110446 | None | code82 | Providing and fixing C.P. brass bib cock of approved quality conform ing to IS:8931 TOILETS | Each | 654.05 | 654.05 | 12.0 | False | None | None | False | None | False | 7848.6 | 0 | 3209643 | 110446 | None | code83 | Providing and fixing C.P. brass angle valve for basin mixer and geyser
points of approved quality conforming to IS:8931 | Each | 638.6 | 638.6 | 18.0 | False | None | None | False | None | False | 11494.8 | 0 | 3209644 | 110446 | None | code84 | Providing and fixing white vitreous china flat back or wall corner type
lipped front urinal basin of 430x260x350 mm or 340x410x265 mm sizes
respectively | Each | 1188.62 | 1188.62 | 9.0 | False | None | None | False | None | False | 10697.58 | 0 | 3209645 | 110446 | None | code85 | Providing and fixing Bidet spray made of Stainless steel with all concealed
fitting arrangements & all necessary accesories complete - Class Premium (HEALTH FAUCET) | Each | 1050.6 | 1050.6 | 10.0 | False | None | None | False | None | False | 10506.0 | 0 | 3209646 | 110446 | None | code86 | PART:B CPVC / GI PIPES AND FITTNGS (INTERNAL AND EXTERNAL WATERSUPPLY) Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: (PVC pipes 25mm dia, 10 kg/sqcm & class 5) | m | 49.44 | 49.44 | 250.0 | False | None | None | False | None | False | 12360.0 | 0 | 3209647 | 110446 | None | code87 | PVC pipes 32mm dia., 10 kg/sqcm & class 5 | m | 69.01 | 69.01 | 250.0 | False | None | None | False | None | False | 17252.5 | 0 | 3209648 | 110446 | None | code88 | Providing and fixing ball valve (brass) of approved quality, High or low
pressure, with plastic floats complete 20 mm nominal bore | Each | 323.42 | 323.42 | 10.0 | False | None | None | False | None | False | 3234.2 | 0 | 3209649 | 110446 | None | code89 | Providing and fixing ball valve (brass) of approved quality, High or low
pressure, with plastic floats complete 25 mm nominal bore | Each | 341.96 | 341.96 | 10.0 | False | None | None | False | None | False | 3419.6 | 0 | 3209650 | 110446 | None | code90 | Providing and fixing Brass full way valve gate with C.I. wheel of
approved quality (screwed end) 32MM NOMINAL BORE | Each | 615.94 | 615.94 | 10.0 | False | None | None | False | None | False | 6159.4 | 0 | 3209651 | 110446 | None | code91 | Constructing brick masonry chamber of internal dimension 600x450mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover. | Nos | 4934.73 | 4934.73 | 50.0 | False | None | None | False | None | False | 246736.5 | 0 | 3209652 | 110446 | None | code92 | Providing and placing on terrace (at all floor levels) polyethylene
water storage tank, IS : 12701 marked, with cover and suitable locking
arrangement and making necessary holes for inlet, outlet and overflow
pipes but without fittings and the base support for tank. | Nos | 9.27 | 9.27 | 30000.0 | False | None | None | False | None | False | 278100.0 | 0 | 3209653 | 110446 | None | code93 | PART:C PVC SOIL, WASTE VENT PIPE & FITTINGS (INTERNAL AND EXTERNAL DRAINAGE SYSTEM) Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: PVC pipes 75mm dia., 6 kg/sqcm & class 3 | m | 226.6 | 226.6 | 150.0 | False | None | None | False | None | False | 33990.0 | 0 | 3209654 | 110446 | None | code94 | Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: PVC pipes 110mm dia., 6 kg/sqcm & class 3 | m | 423.33 | 423.33 | 250.0 | False | None | None | False | None | False | 105832.5 | 0 | 3209655 | 110446 | None | code95 | Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: PVC pipes 160mm dia., 6 kg/sqcm & class 3 | m | 636.54 | 636.54 | 80.0 | False | None | None | False | None | False | 50923.2 | 0 | 3209656 | 110446 | None | code96 | Constructing brick masonry chamber of internal dimension 450x450mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.. | No | 4363.08 | 4363.08 | 11.0 | False | None | None | False | None | False | 47993.88 | 0 | 3209657 | 110446 | None | code97 | Constructing brick masonry chamber of internal dimension 600x450mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover. | No | 4934.73 | 4934.73 | 5.0 | False | None | None | False | None | False | 24673.65 | 0 | 3209658 | 110446 | None | code98 | Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work. In all kinds of soils. Depth upto 1.50m | Cum | 4988.29 | 4988.29 | 25.0 | False | None | None | False | None | False | 124707.25 | 0 | 3209659 | 110446 | None | code99 | POINT WIRING USING COPPER WIRE WITHOUT SWITCH Supplying and wiring adopting loop system in the existing PVC conduit/casing capping using 1100V grade, copper conductor flexible multistrand FRLS PVC insulated multistrand 2 x 1.5 sq.mm cable confirming to the GTP, without switch, the other end of the wires shall be terminated with sufficient loose length in a PVC round block , complete for each outlet. point wiring using class A Materials Short point upto 3 mts from tapping point to out let via switch | Point | 269.0 | 269.0 | 400.0 | False | None | None | False | None | False | 107600.0 | 0 | 3209660 | 110446 | None | code100 | Medium point above 3 mts upto 6mts from tapping point to outlet via switch | Point | 379.0 | 379.0 | 250.0 | False | None | None | False | None | False | 94750.0 | 0 | 3209661 | 110446 | None | code101 | Long point above 6 mts upto 10 mts from tapping point to outlet via switch | Point | 555.0 | 555.0 | 250.0 | False | None | None | False | None | False | 138750.0 | 0 | 3209662 | 110446 | None | code102 | Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 1 - 3Way | Each | 159.0 | 159.0 | 150.0 | False | None | None | False | None | False | 23850.0 | 0 | 3209663 | 110446 | None | code103 | Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 4 - 5Way | Each | 177.0 | 177.0 | 150.0 | False | None | None | False | None | False | 26550.0 | 0 | 3209664 | 110446 | None | code104 | Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 6 Way | Each | 220.0 | 220.0 | 125.0 | False | None | None | False | None | False | 27500.0 | 0 | 3209665 | 110446 | None | code105 | Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 8 Way | Each | 261.0 | 261.0 | 150.0 | False | None | None | False | None | False | 39150.0 | 0 | 3209666 | 110446 | None | code106 | Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 10 / 12 Way | Each | 319.0 | 319.0 | 75.0 | False | None | None | False | None | False | 23925.0 | 0 | 3209667 | 110446 | None | code107 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 1 to 3 Module | Each | 152.0 | 152.0 | 150.0 | False | None | None | False | None | False | 22800.0 | 0 | 3209668 | 110446 | None | code108 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 4 Module | Each | 175.0 | 175.0 | 150.0 | False | None | None | False | None | False | 26250.0 | 0 | 3209669 | 110446 | None | code109 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 6 Module | Each | 234.0 | 234.0 | 175.0 | False | None | None | False | None | False | 40950.0 | 0 | 3209670 | 110446 | None | code110 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 8 Module | Each | 284.0 | 284.0 | 80.0 | False | None | None | False | None | False | 22720.0 | 0 | 3209671 | 110446 | None | code111 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 12 Module | Each | 344.0 | 344.0 | 80.0 | False | None | None | False | None | False | 27520.0 | 0 | 3209672 | 110446 | None | code112 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6 amps one way switch | Each | 102.0 | 102.0 | 400.0 | False | None | None | False | None | False | 40800.0 | 0 | 3209673 | 110446 | None | code113 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6 amps two way switch | Each | 166.0 | 166.0 | 400.0 | False | None | None | False | None | False | 66400.0 | 0 | 3209674 | 110446 | None | code114 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6 Amps 3 way sockets | Each | 171.0 | 171.0 | 50.0 | False | None | None | False | None | False | 8550.0 | 0 | 3209675 | 110446 | None | code115 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 stepped fan Regulator's | Each | 357.0 | 357.0 | 180.0 | False | None | None | False | None | False | 64260.0 | 0 | 3209676 | 110446 | None | code116 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6/16 Amps universal sockets | Each | 236.0 | 236.0 | 50.0 | False | None | None | False | None | False | 11800.0 | 0 | 3209677 | 110446 | None | code117 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 16A one way switch | Each | 236.0 | 236.0 | 50.0 | False | None | None | False | None | False | 11800.0 | 0 | 3209678 | 110446 | None | code118 | Supplying and fixing M.S.Rafter clamp set made out of M.S flat & 14mm M.S.rod | Each | 160.0 | 160.0 | 180.0 | False | None | None | False | None | False | 28800.0 | 0 | 3209679 | 110446 | None | code119 | Supply and fixing one metal Fan box with round hook | Each | 117.0 | 117.0 | 180.0 | False | None | None | False | None | False | 21060.0 | 0 | 3209680 | 110446 | None | code120 | Concealed Conduit System Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary 20 mm dia | Mtr | 66.0 | 66.0 | 400.0 | False | None | None | False | None | False | 26400.0 | 0 | 3209681 | 110446 | None | code121 | Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary 25 mm dia | Mtr | 78.0 | 78.0 | 300.0 | False | None | None | False | None | False | 23400.0 | 0 | 3209682 | 110446 | None | code122 | Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary 32 mm dia | Mtr | 103.0 | 103.0 | 200.0 | False | None | None | False | None | False | 20600.0 | 0 | 3209683 | 110446 | None | code123 | Groove Cutting in Wall Supplying 2 mm thick heavy gauge PVC conduit pipe with bends metal junction boxes adhesives paste etc and bracing U or J hooks and cement plastering upto the surface of the trick level and run with 18 SWG Gi fish wire run through out the conduit wherever necessary 20 mm dia | Mtr | 68.0 | 68.0 | 400.0 | False | None | None | False | None | False | 27200.0 | 0 | 3209684 | 110446 | None | code124 | Supplying 2 mm thick heavy gauge PVC conduit pipe with bends metal junction boxes adhesives paste etc and bracing U or J hooks and cement plastering upto the surface of the trick level and run with 18 SWG Gi fish wire run through out the conduit wherever necessary 25 mm dia | Mtr | 79.0 | 79.0 | 300.0 | False | None | None | False | None | False | 23700.0 | 0 | 3209685 | 110446 | None | code125 | Supplying 2 mm thick heavy gauge PVC conduit pipe with bends metal junction boxes adhesives paste etc and bracing U or J hooks and cement plastering upto the surface of the trick level and run with 18 SWG Gi fish wire run through out the conduit wherever necessary 32 mm dia | Mtr | 99.0 | 99.0 | 200.0 | False | None | None | False | None | False | 19800.0 | 0 | 3209686 | 110446 | None | code126 | Supplying and fixing PVC/metal conduit deep junction box. 19/20mm deep junction box | Mtr | 49.0 | 49.0 | 100.0 | False | None | None | False | None | False | 4900.0 | 0 | 3209687 | 110446 | None | code127 | Supplying and fixing PVC/metal conduit deep junction box. 25mm deep junction box | Each | 56.0 | 56.0 | 50.0 | False | None | None | False | None | False | 2800.0 | 0 | 3209688 | 110446 | None | code128 | WIRING FOR Lighting/Power Circuits FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to GTP 1.5 Sq.mm | Mtr | 26.0 | 26.0 | 500.0 | False | None | None | False | None | False | 13000.0 | 0 | 3209689 | 110446 | None | code129 | FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to GTP 2.5 sq.mm | Mtr | 42.0 | 42.0 | 400.0 | False | None | None | False | None | False | 16800.0 | 0 | 3209690 | 110446 | None | code130 | FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to GTP 4 sq.mm | Mtr | 63.0 | 63.0 | 300.0 | False | None | None | False | None | False | 18900.0 | 0 | 3209691 | 110446 | None | code131 | FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to GTP 6sq.mm | Mtr | 92.0 | 92.0 | 250.0 | False | None | None | False | None | False | 23000.0 | 0 | 3209692 | 110446 | None | code132 | FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to GTP 10sq.mm | Mtr | 167.0 | 167.0 | 200.0 | False | None | None | False | None | False | 33400.0 | 0 | 3209693 | 110446 | None | code133 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 1.5 sq.mm | Each | 3.0 | 3.0 | 400.0 | False | None | None | False | None | False | 1200.0 | 0 | 3209694 | 110446 | None | code134 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 2.5 sq.mm | Each | 4.0 | 4.0 | 300.0 | False | None | None | False | None | False | 1200.0 | 0 | 3209695 | 110446 | None | code135 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 4 sq.mm | Each | 7.0 | 7.0 | 350.0 | False | None | None | False | None | False | 2450.0 | 0 | 3209696 | 110446 | None | code136 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 6 sq.mm | Each | 7.0 | 7.0 | 300.0 | False | None | None | False | None | False | 2100.0 | 0 | 3209697 | 110446 | None | code137 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 10 sq.mm | Each | 8.0 | 8.0 | 250.0 | False | None | None | False | None | False | 2000.0 | 0 | 3209698 | 110446 | None | code138 | Supplying and fixing regular MCB distribution boards on wall/ oodboard/ flush mounting using required clamps ,bolts, nutsetc., with provision for fixing suitable type capacity MCB's single phase /3phase /singledoor with powdercoated painting Made out of 14 SWGMS enclosure. II - Double Door 4Way TP & N | Each | 1524.0 | 1524.0 | 15.0 | False | None | None | False | None | False | 22860.0 | 0 | 3209699 | 110446 | None | code139 | Supplying and fixing regular MCB distribution boards on wall/ oodboard/ flush mounting using required clamps ,bolts, nutsetc., with provision for fixing suitable type capacity MCB's single phase /3phase /singledoor with powdercoated painting Made out of 14 SWGMS enclosure. II - Double Door 8 Way SP & N | Each | 1854.0 | 1854.0 | 10.0 | False | None | None | False | None | False | 18540.0 | 0 | 3209700 | 110446 | None | code140 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing material sand 'C' Type curve ,indicatorON/OFF ,energycross- 3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC60898. 6 to 32 Amps SP | Each | 415.0 | 415.0 | 25.0 | False | None | None | False | None | False | 10375.0 | 0 | 3209701 | 110446 | None | code141 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing material sand 'C' Type curve ,indicatorON/OFF ,energycross- 3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC60898. 6 to 32 Amps DP | Each | 739.0 | 739.0 | 15.0 | False | None | None | False | None | False | 11085.0 | 0 | 3209702 | 110446 | None | code142 | Supplying, fixing and wiring Residual current circuit breaker (RCCB)240/450V upto 300mA sensitivity on existing wood/ panel board. 32-40 Amps 2 pole | Each | 4559.0 | 4559.0 | 5.0 | False | None | None | False | None | False | 22795.0 | 0 |
|
|
---|