3203538 | 110112 | None | code01 | Geophysical investigation at site for sinking borewells for Providing drinking water to the habitation either through the Hand Pump MW Sor PWSS by vertical electrical sounding by adopting Venner or Schlumbergers's method including reconnaissance survey of geological formation Geophysical investigation of existing ground water in the vicinity its quality quantity and acceptability of the users indicating the location of the site recommended depth of casing pipe required to seal the top unconsolidated formation including an extra depth of 10 metre in consolidated formation for proper seating of casing pipe depth of drilling required to cover full depth of aquifer proposed to be tapped probable yield and other information required including transportation of instruments and accessories to work site engaging technical personaland labour required etc NOTE 1 Additional rate on item 12 is allowed for drilling in over burden and fixing Casing pipes beyond 20M for fixing Casing pipes only a Above 20 M and upto 30 M 15 bAbove 30 M 30 Measurement of overburden is restricted to the depth of casing pipe fixed excluding initial depth of 20M and projection above ground level 2 A sum of Rs 100/- is to be deducted for Dry Borewell towards yield test | Each | 5552.4 | 5552.4 | 3.0 | False | None | None | False | None | False | 16657.2 | 0 |
3203539 | 110112 | None | code02 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG above 1100 CMF above in all strata including over burdern upto 20 m Fixing of casing pipes collars and cap with necessary cutting threading and welding including transportation of rig and supporting vehicle crew charges and cost of consumables etc complete including yield testing at the final depth with a minimum working of compressor for one hour Excluding cost of casing pipes collars cap etc complete Above 450m of drilling add 10 for every 50m depth Borewell depth of 0 to 50 Mtrs | Mtr | 388.5 | 388.5 | 150.0 | False | None | None | False | None | False | 58275.0 | 0 |
3203540 | 110112 | None | code03 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG above 1100 CMF above in all strata including over burdern upto 20 m Fixing of casing pipes collars and cap with necessary cutting threading and welding including transportation of rig and supporting vehicle crew charges and cost of consumables etc complete including yield testing at the final depth with a minimum working of compressor for one hour Excluding cost of casing pipes collars cap etc complete Above 450m of drilling add 10 for every 50m depth Borewell depth of 50 to 100 Mtrs | Mtr | 487.2 | 487.2 | 133.0 | False | None | None | False | None | False | 64797.6 | 0 |
3203541 | 110112 | None | code04 | Providing PVC ringtite pipes conforming to IS 49852000 with latest amendments and conveying to worksite rolling and lowering into trenches laying true to line and level and perfect linking at joints testing and commissioning including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials excluding cost of specials with jointing of approved type with all labour with all lead lift including encasing the pipe alround to a depth of not less than 15 cms with soft gravel or selected earth available from the excavation etc complete and giving necessary hydraulic test to the required pressure as per ISS Contractor will make his own arrangements for procuring water for testing etc com PVC pipes 160mm DIA 6KG/sq cm Class 3 | Mtr | 648.9 | 648.9 | 27.0 | False | None | None | False | None | False | 17520.3 | 0 |
3203542 | 110112 | None | code05 | Providing Single Phase Submersible Pump Sets of 100mm dia 4 inch suitable for bore well confirming to IS 8034-2000 specifications to work site with testing of as per instructions of engineer incharge of work and latest amendments 26 STG | Each | 20380.5 | 20380.5 | 3.0 | False | None | None | False | None | False | 61141.5 | 0 |
3203543 | 110112 | None | code06 | Supply and delivery at site Brand new best make PVC insulated cable of Flat 3 core sheathed of nominal cross sectional area as per IS 694 1990 with ISI Mark and as per its latest amendments | Mtr | 194.25 | 194.25 | 60.0 | False | None | None | False | None | False | 11655.0 | 0 |
3203544 | 110112 | None | code07 | Supply installingtesting and commissioning COMMON control panel consisting of the following INCOMING1 No set of Phase indicating lamps with SFU of suitable rating 1 No Analog Ammeter 1 No Analog Voltmeter 1ni with Phase selector switch Isolating switch OUTGOING for Main Electrical Pump 1 No MCB 1 No DOL of S/D Starter suitable for re pective HP 1 No Electrcal Protection Like single Phase preventor under voltage over Volage under current over current dry run protection suitable for the pump described above 1 no Indoor type NOTE 1 DOL- Direct Online Starter Upto 3 HP pumps 2 S-D- Star Delta Starter etc complete | Each | 7875.0 | 7875.0 | 3.0 | False | None | None | False | None | False | 23625.0 | 0 |
3203545 | 110112 | None | code08 | Labour charges for providing connection using insulated sheathed steel wire cable as per IS 1554/ 1988 with latest amendments from KPTCL pole to meter board unit with all necessary materials tools and equipmentsas per specificationswith testing of as per instructions of engineer incharge of work | Mtr | 168.0 | 168.0 | 30.0 | False | None | None | False | None | False | 5040.0 | 0 |
3203546 | 110112 | None | code09 | Supply and delivery at site brand new best make pressure guage suitable for centrifugal pump confirming to latest IS standards pressure guage 80MM | Each | 626.85 | 626.85 | 3.0 | False | None | None | False | None | False | 1880.55 | 0 |
3203547 | 110112 | None | code10 | Supply and delivery at site best indigenous brand new power capacitor as per IS 2834/1986 with latest amendments with KPTCL authorities and erection electrification and commissioning of the same at the location of respective pump sets | Kvar | 577.5 | 577.5 | 3.0 | False | None | None | False | None | False | 1732.5 | 0 |
3203548 | 110112 | None | code11 | Supply and delivery at site 50mm2 dia heavy duty unplasticized PVC Column pipes with heavy duty collarsrubber profile ringvibration control profile ringfreezing and turbulence free leak proof EPDM ring with ISI mark with its latest amendments | Mtr | 577.5 | 577.5 | 48.0 | False | None | None | False | None | False | 27720.0 | 0 |
3203549 | 110112 | None | code12 | Supply and delivery at site of brand new best make non-return valve as
per IS 778/1984 with ISI Mark and as per its latest amendments Size 50 mm | Each | 1312.5 | 1312.5 | 3.0 | False | None | None | False | None | False | 3937.5 | 0 |
3203550 | 110112 | None | code13 | Labour charges for Erection Electrification and commissioning of Pump sets including aligning and balancing of all items including supply and erection of two pair of supporting clamps bore well caps cable clips and water tight gland cable protectors bolts nuts valve and gaugestools and equipments etc involved in the job as per specifications with necessary tests as per specifications with testing of as per instructions of engineer incharge of work | Job | 6825.0 | 6825.0 | 3.0 | False | None | None | False | None | False | 20475.0 | 0 |
3203551 | 110112 | None | code14 | Labour charges for erection of outdoor type panel board and meter board
units with all necessary materials and labour tools and equipments including providing cement concrete foundation bed etc complete as per specification with testing of as per instructions of engineerincharge of work | Job | 1522.5 | 1522.5 | 3.0 | False | None | None | False | None | False | 4567.5 | 0 |
3203552 | 110112 | None | code15 | RCC hume pipe Circular pump house Providing precast RCC Circular Hume pipe pump house with MS door and RCC conical roof as per specification and drawings - Internal dia Mtr 1200 mm height of 25 Mtr With Wall thickness 65mm etc complete | Each | 17221.05 | 17221.05 | 3.0 | False | None | None | False | None | False | 51663.15 | 0 |
3203553 | 110112 | None | code16 | Erection and positioning of RCC Hume pipe pump house Cistern on size stone masory platform including transportation charges and andlingfinishing with all necessary tools plants and materials etccomplete as directed by the Engineer in charge of work | Each | 1976.1 | 1976.1 | 3.0 | False | None | None | False | None | False | 5928.3 | 0 |
3203554 | 110112 | None | code17 | Earth work excavation by manual means for drains canals waste weir draft approach channels key trenches foundation of Buildings bridges and such
simillar works in all kinds of soils as per drawing and technical specifications
including setting out shoring strutting barricading caution lights removal of stumps and other deleterious matter excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting stacking the selected stuff for reuse in a radius of 50 m and lift upto 15 m including cost of
labour tools other appurtenaces required to complete the work | Cum | 254.1 | 254.1 | 3.39 | False | None | None | False | None | False | 861.399 | 0 |
3203555 | 110112 | None | code18 | Providing and laying in position Cement Concrete for levelling course for
all works in foundation The granite trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed laid
layers not exceeding 150 mm thickness well compacted using plate vibrators
including all lead lifts cost of all materials of quality labour Usage charges of
machinery curing and all the other appurtenances required to complete the
work as per technical specifications Mix 136 Using 40 mm nominal size graded crushed coarse aggregates | Cum | 6288.45 | 6288.45 | 0.69 | False | None | None | False | None | False | 4339.0305 | 0 |
3203556 | 110112 | None | code19 | Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1612 1 cement 6 coarse sand 12 graded stone aggregate 20 mm nominal size upto plinth level with Cement mortar 16 1 cement 6 coarse sand | Cum | 5891.55 | 5891.55 | 2.04 | False | None | None | False | None | False | 12018.762 | 0 |
3203557 | 110112 | None | code20 | Providing Size Stone masonry with hard stone in foundation plinth with Cement mortar 16 1 cement 6 coarse sand | Cum | 6708.45 | 6708.45 | 1.65 | False | None | None | False | None | False | 11068.9425 | 0 |
3203558 | 110112 | None | code21 | Providing and laying in position Cement Concrete for levelling course for all works in foundation The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed laid in layers not exceeding 150 mm thickness well compacted using plate vibrators including all lead lifts cost of all materials of quality labour Usage charges of machinery curing and all the other appurtenances required to complete the work as per technical specifications Mix 124 Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6555.15 | 6555.15 | 1.02 | False | None | None | False | None | False | 6686.253 | 0 |
3203559 | 110112 | None | code22 | Providing 20 mm cement plaster of mix 16 1 cement 6 fine sand to brick/stone masonry including rounding off corners wherever required smooth rendering providing and removing scaffolding including cost of materials labour curing complete as per specifications and as per directions of Engineer-in-charge | Sqm | 349.65 | 349.65 | 2.25 | False | None | None | False | None | False | 786.7125 | 0 |
3203560 | 110112 | None | code23 | Providing Laying and Fixing of GI pipes conforming to IS 12391990 with latest amendments complete with GI fittings excluding the cost of fittings with cuts and threads wherever necessary including testing for water tightness with all lead and commissioning contractor will make his own arrangements for procuring water for testing ForHeavy Duty GI Pipe etc complete Heavy Duty GI pipe of 32mm dia | Mtr | 449.4 | 449.4 | 18.0 | False | None | None | False | None | False | 8089.2 | 0 |