createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1716980362487
version4
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeONE_COVER
evaluationTypeTextOne Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee500.00
emd36500.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose07-06-2024 17:00:00
tenderQueryClose05-06-2024 17:30:00
technicalBidOpenNone
publishedDate30-05-2024 16:24:18
publishedByPostPWD_EE_DIV_CKD
publishedByUserKPE15950 - SUNILKUMAR N BALOL
bidValidityPeriod90
noOfCalls1
preBidMeetingDateNone
preBidMeetingYnFalse
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonShri. Sunilkumar N Balol EE PWD Division Chikodi
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumber08338273859
mobileNumber8338273859
tenderSupplierListNone
tenderSchedule
createdTs1716980362527
version7
createdDateNone
modifiedDateNone
tenderNumberPWD/2024-25/BD/WORK_INDENT10928
titleCONSTRUCTION OF SINGLE CLASS ROOMS FOR KANNADA MEDIUM SCHOOL IN DIGGEWADI IN RAIBAG TALUKA OF BELAGAVI DISTRICT HOA 4059-80-051-0-29-386 DEPARTMENTAL BUILDINGS FOR THE YEAR 2023-24
descriptionCONSTRUCTION OF SINGLE CLASS ROOMS FOR KANNADA MEDIUM SCHOOL IN DIGGEWADI IN RAIBAG TALUKA OF BELAGAVI DISTRICT HOA 4059-80-051-0-29-386 DEPARTMENTAL BUILDINGS FOR THE YEAR 2023-24
categoryWORKS
categoryTextWorks
ecv1452053.07
deptNamePublic Works Department
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnTrue
location1686
locationNamePWD Division Office Chikkodi
provisionalAmount1800000.0
groupOverheadTotalNone
fileNumberKPWD/RBG/BD/DIGGEWADI/2024-25
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17169803630000NoneNoneBuildingsCONSTRUCTION OF SINGLE CLASS ROOMS FOR KANNADA MEDIUM SCHOOL IN DIGGEWADI IN RAIBAG TALUKA OF BELAGAVI DISTRICT HOA 4059-80-051-0-29-386 DEPARTMENTAL BUILDINGS FOR THE YEAR 2023-241374052.07
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3199779109996NoneVol.1, P.No.8,I.No.1.12Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter includingdressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage ofmachinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depth ( Vol.1, P.No.8,I.No.1.12) ---- with all lead and liftsCum99.7599.7518.27FalseNoneNoneFalseNoneFalse1822.43250
3199780109996NoneVol.1, P.No.8,I.No.1.14.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications,including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m ( Vol.1, P.No.8,I.No.1.14.1) ---- with all lead and liftsCum107.1107.144.49FalseNoneNoneFalseNoneFalse4764.8790
3199781109996NoneVol.1, P.No.15,I.No.2.1.3Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness,well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Formwork included and (The cost of steel reinforcement shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates ( Vol.1, P.No.15,I.No.2.1.3) ---- with all lead and liftsCum6288.456288.4515.26FalseNoneNoneFalseNoneFalse95961.7470
3199782109996NoneVol.2, P.No.5,I.No.4.1Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications. ( Vol.2, P.No.5,I.No.4.1) ---- with all lead and liftsSqm123.9123.958.93FalseNoneNoneFalseNoneFalse7301.4270
3199783109996NoneVol.2, P.No.9,I.No.5.3Providing Coursed rubble masonry (second sort) with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) ( Vol.2, P.No.9,I.No.5.3) ---- with all lead and liftsCum6515.256515.2511.46FalseNoneNoneFalseNoneFalse74664.7650
3199784109996NoneVolume 1 Page No 15-Item No 2.2.3Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (The cost of steel reinforcement & formwork to be paid separately) (Volume 1 Page No 15-Item No 2.2.3) ---- with all lead and liftsCum6652.86652.87.38FalseNoneNoneFalseNoneFalse49097.6640
3199785109996NoneVol.1, P.No.111, S.No.1aFormwark for Footings Isolated @ 8% (Vol.1, P.No.111, S.No.1a) ---- with all lead and liftsCum532.22532.227.38FalseNoneNoneFalseNoneFalse3927.78360
3199786109996NoneVol.1, P.No.16, I.No.2.4.3Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ( Vol.1, P.No.16, I.No.2.4.3) ---- with all lead and liftsCum6652.86652.84.26FalseNoneNoneFalseNoneFalse28340.9280
3199787109996NoneVol.1, P.No.111, S.No.9Formwark for Columns @ 70% (Vol.1, P.No.111, S.No.9) ---- with all lead and liftsCum4656.964656.961.44FalseNoneNoneFalseNoneFalse6706.02240
3199788109996NoneVol.1, P.No.111, S.No.2Formwark for Plinth beams of Buildings @ 50% (Vol.1, P.No.111, S.No.2) ---- with all lead and liftsCum3326.43326.42.82FalseNoneNoneFalseNoneFalse9380.4480
3199789109996NoneVol.1,P.No.7, I.No.1.9Filling available excavated earth (excluding rock) in trenches, plinth,sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. ( Vol.1,P.No.7, I.No.1.9) ---- with all lead and liftsCum279.3279.324.55FalseNoneNoneFalseNoneFalse6856.8150
3199790109996NoneVol.1, P.No.16,I.No.2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ( Vol.1, P.No.16,I.No.2.5.2) ---- with all lead and liftsCum7185.157185.1517.41FalseNoneNoneFalseNoneFalse125093.46150
3199791109996NoneVol.1, P.No.111, S.No.9Formwark for Columns @ 70% (Vol.1, P.No.111, S.No.9) ---- with all lead and liftsCum5029.615029.613.73FalseNoneNoneFalseNoneFalse18760.44530
3199792109996NoneVol.1, P.No.112, S.No.14Formwark for Beams & Lintels of Building @ 60% (Vol.1, P.No.112, S.No.14) ---- with all lead and liftsCum4311.094311.093.6FalseNoneNoneFalseNoneFalse15519.9240
3199793109996NoneVol.1, P.No.112, S.No.15Formwark for Roof Slab of Building @ 50% (Vol.1, P.No.112, S.No.15) ---- with all lead and liftsCum3592.583592.588.84FalseNoneNoneFalseNoneFalse31758.40720
3199794109996NoneVol.1, P.No.112, S.No.1Formwark for Chejjas, Canopy & Other Architectural projections of minor sections @ 45% (Vol.1, P.No.112, S.No.1 ---- with all lead and liftsCum3233.323233.321.24FalseNoneNoneFalseNoneFalse4009.31680
3199795109996NoneVol.1, P.No.16, I.No.2.4.1Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) Mix 1:2:4 (M15) Using 20 mm nominal size graded crushed coarse aggregates ( Vol.1, P.No.16, I.No.2.4.1) ---- with all lead and liftsCum6724.26724.21.21FalseNoneNoneFalseNoneFalse8136.2820
3199796109996NoneVol.1, P.No.18,I.No.2.11aProviding Thermo-Mechanically Treated bars of grade Fe-550 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) (Vol.1, P.No.18,I.No.2.11a) ---- with all lead and liftst93929.8593929.852.57FalseNoneNoneFalseNoneFalse241399.71450
3199797109996NoneVol.2 P.No.14, I. No. 6.8Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.(Vol.2 P.No.14, I. No. 6.8) ---- with all lead and liftsCum8367.458367.4519.3FalseNoneNoneFalseNoneFalse161491.7850
3199798109996NoneVolume 2 Page No 99 Item No 12.11Providing Honne wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications.(Volume 2 Page No 99 Item No 12.11) ---- with all lead and liftsCum144977.7144977.70.122FalseNoneNoneFalseNoneFalse17687.27940
3199799109996NoneVol. 2, P. No.105, I.No.12.57.8Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification.-do- 40 mm thick one side teak and one side commercial.(Vol. 2, P. No.105, I.No.12.57.8) ---- with all lead and liftsSqm4515.04515.05.04FalseNoneNoneFalseNoneFalse22755.60
3199800109996NoneVol. 2, P.No. 63, I. No.9.24Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent (Vol. 2, P.No. 63, I. No.9.24) ---- with all lead and liftsSqm2994.62994.65.76FalseNoneNoneFalseNoneFalse17248.8960
3199801109996NoneVol. 2, P.No.108, I.No.12.84Providing & fixing of 2-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6 PHR with TPE (Thermo Plastic Elastomer) and lead free, gaskets -grey color having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 44mm width x 40mmheight with reinforcement of 1mm thickness and Sash with overall size of 27mm X 53mm with UPVC honeycomb structure inside in lieu of GI reinforcement. Coextruded Glazing bead for fixing of glass shall be of size 9.5mm x 21.5mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with Crescent Locks. Wall thickness of frame & sash shall be of 2 mm.Maximum possible size 1219mm x 1219mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made (Vol. 2, P.No.108, I.No.12.84) ---- with all lead and liftsSqm5274.155274.154.32FalseNoneNoneFalseNoneFalse22784.3280
3199802109996NoneVol. 2 Material component S.No.394, P.No. A-24Galvanised wire mesh of average width of aperture 1.4 mm and nominal dia of wire 0.63 mm (Vol. 2 Material component S.No.394, P.No. A-24) ---- with all lead and liftsSqm280.0280.06.48FalseNoneNoneFalseNoneFalse1814.40
3199803109996NoneVol.2, P.No.86, I.No.11.34BProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc (Vol.2, P.No.86, I.No.11.34B) ---- with all lead and liftsKgs192.15192.15116.64FalseNoneNoneFalseNoneFalse22412.3760
3199804109996NoneVol.2, P.No.61, I.No.9.12.2Providing and laying Vitrifiedfloor tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mm (Vol.2, P.No.61, I.No.9.12.2) ---- with all lead and liftsSqm1202.251202.2533.98FalseNoneNoneFalseNoneFalse40852.4550
3199805109996NoneVol.2, P.No.41, I.No.8.1.1Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding,including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge (Vol.2, P.No.41, I.No.8.1.1) ---- with all lead and liftsSqm267.75267.75114.3FalseNoneNoneFalseNoneFalse30603.8250
3199806109996NoneVol.2, P.No.50, I.No.8.51Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. (Vol.2, P.No.50, I.No.8.51) ---- with all lead and liftsSqm105.0105.0117.69FalseNoneNoneFalseNoneFalse12357.450
3199807109996NoneVol.2, P.No.42, I.No.8.8Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(Vol.2, P.No.42, I.No.8.8 ) ---- with all lead and liftsSqm389.55389.55162.38FalseNoneNoneFalseNoneFalse63255.1290
3199808109996NoneVol.2, P.No.64, I.No.9.36Providing flooring with 25mm thick polished Cuddapah slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab , including cost of materials, labour, curing, polishing complete as per specifications. (Vol.2, P.No.64, I.No.9.36) ---- with all lead and liftsSqm1732.51732.53.11FalseNoneNoneFalseNoneFalse5388.0750
3199809109996NoneVol.2, P.No.47, I.No.8.33.3Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @ 0.80 ltr/10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge (Vol.2, P.No.47, I.No.8.33.3) ---- with all lead and liftsSqm145.95145.956.48FalseNoneNoneFalseNoneFalse945.7560
3199810109996NoneVol.2, P.No.46, I.No.8.33.2Painting wood work with Deluxe Multi Surface Paint of required shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @0.75 ltr/10 m² of approved brand and manufacture to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge (Vol.2, P.No.46, I.No.8.33.2) ---- with all lead and liftsSqm144.9144.916.13FalseNoneNoneFalseNoneFalse2337.2370
3199811109996NoneVol.2, P.No.46, I.No.8.30Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (Vol.2, P.No.46, I.No.8.30) ---- with all lead and liftsSqm182.7182.7204.5FalseNoneNoneFalseNoneFalse37362.150
3199812109996NoneVol.2, P.No.46, I.No.8.33.1Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Special primer applied @ 0.75 ltr /10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (Vol.2, P.No.46, I.No.8.33.1) ---- with all lead and liftsSqm165.9165.9117.69FalseNoneNoneFalseNoneFalse19524.7710
3199813109996NoneVol.2,P. No.105, I.No.12.51Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications.(Vol.2,P. No.105, I.No.12.51) ---- with all lead and liftsNos1066.81066.82.0FalseNoneNoneFalseNoneFalse2133.60
3199814109996NoneVol.5,P.No.125,I.No.13.48Providing and fixing on the wall face unplastisized rigid PVC rain water pipes confirmimg to IS:13592 Type A including jointing with seal ring confirmimg to IS:5382, leaving 10mm gap for thermal expansion, single socketed pipes 100mm diameter. ( Vol.5,P.No.125,I.No.13.48) ---- with all lead and liftsm305.55305.5515.0FalseNoneNoneFalseNoneFalse4583.250
3199815109996NoneVol.2, P.No.84, I.No.11.26.1Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. M.S. tube including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineerin-Charge. (Vol.2, P.No.84, I.No.11.26.1) ---- with all lead and liftsKgs144.9144.9150.0FalseNoneNoneFalseNoneFalse21735.00
3199816109996NoneVol.2, P.No.149, I.No.15.1Polyurethane based Single Component for New Surface: Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge. (Vol.2, P.No.149, I.No.15.1) ---- with all lead and liftsSqm857.85857.8555.11FalseNoneNoneFalseNoneFalse47276.11350
3199817109996NoneQuotation rateProviding and fixing Green board for class room (Quotation rate) ---- with all lead and liftsEach8136.08136.02.0FalseNoneNoneFalseNoneFalse16272.00
3199818109996NoneVol.2, P.No.200, I.No.20.34.1Providing and fixing chromium plated brass butt hinges with necessary chromium plated brass screws etc. complete.125x70x4 mm (ordinary type) (Vol.2, P.No.200, I.No.20.34.1) ---- with all lead and liftsNo178.5178.54.0FalseNoneNoneFalseNoneFalse714.00
3199819109996NoneVol.2, P.No.A-25, S.No.444Hold fasts (Vol.2, P.No.A-25, S.No.444) ---- with all lead and liftsNos50.050.06.0FalseNoneNoneFalseNoneFalse300.00
3199820109996NoneVol.2, P.No.107, I.No.12.73.1Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete 125mm (Vol.2, P.No.107, I.No.12.73.1) ---- with all lead and liftsNo46.246.22.0FalseNoneNoneFalseNoneFalse92.40
3199821109996NoneVol.2, P.No.105, I.No.12.60Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.(Vol.2, P.No.105, I.No.12.60) ---- with all lead and liftsNo1104.61104.61.0FalseNoneNoneFalseNoneFalse1104.60
3199822109996NoneVol.2, P.No.107, I.No.12.63Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete (Vol.2, P.No.107, I.No.12.63) ---- with all lead and liftsNos136.5136.52.0FalseNoneNoneFalseNoneFalse273.00
3199823109996NoneVol. 2, P.No. 63, I. No.9.23Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : ** Flamed finish granite stone slab Black, Cat Eye, River Pink or equivalent. (Vol. 2, P.No. 63, I. No.9.23) ---- with all lead and liftsSqm2589.32589.325.97FalseNoneNoneFalseNoneFalse67244.1210
17169803630000NoneNoneBuildingsFURNITURES TABLE AND CHAIR33520.0
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3199824109997NoneKSFIC DWD 052Teak Wood Table : Of size 6'x3'. Leg size 2.5"x2.5". Table frame to be 4"x1.25" thick pattis. Foot rest to be provided with 2"x1.5"=2 Nos. Table top to be laminated with 1mm thick laminate with teak edge banding lower side middle H - Shape patti. Table shall be neatly finished and polished. ---- with all lead and liftsNo23540.023540.01.0FalseNoneNoneFalseNoneFalse23540.00
3199825109997NoneKSFIC DWD 069Teak wood Chair (Heavy model): Seat with taek wood planks or cushion. Made out of teak wood chair 3''x1.25'' back legs 2.25''x2.25'' front legs chair side side bars 3''x1.25'' back with 8 reapers. Chair size standard size. Chair shall be neatly finished and polished. ---- with all lead and liftsNo9980.09980.01.0FalseNoneNoneFalseNoneFalse9980.00
17169803630000NoneNoneBuildingsELECTRICAL ESTIMATE44481.0
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3199826109998None1.8.2Supplying and fixing of PVC casing and capping on the wall or ceilingusing necessary materials like bends, junction box, elbows, screws at an interval of 300 mm as required. ---- with all lead and liftsMtr35.035.080.0FalseNoneNoneFalseNoneFalse2800.00
3199827109998None1.6.5Supplying and flush mounting teak wooden box without front plank, made of not less than 12 mm thick wood, after due groove cutting, finishing with necessary cement plastering complete ---- with all lead and liftsEach74.074.08.0FalseNoneNoneFalseNoneFalse592.00
3199828109998None2.1.2Point wiring using Copper wire with switch: Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. ---- with all lead and liftsPoint394.0394.04.0FalseNoneNoneFalseNoneFalse1576.00
3199829109998None2.1.3Long point above 6Mtr upto 10Mtr from tapping point to out let via switch ---- with all lead and liftsPoint570.0570.04.0FalseNoneNoneFalseNoneFalse2280.00
3199830109998None2.3.2Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010.1.5MSQM ---- with all lead and liftsMtr26.026.0125.0FalseNoneNoneFalseNoneFalse3250.00
3199831109998None2.3.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010.2.5MSQM ---- with all lead and liftsMtr42.042.015.0FalseNoneNoneFalseNoneFalse630.00
3199832109998None2.3.4Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010.4MSQM ---- with all lead and liftsMtr63.063.075.0FalseNoneNoneFalseNoneFalse4725.00
3199833109998None3.4.1Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall.1.2 WAY ---- with all lead and liftsEach138.0138.03.0FalseNoneNoneFalseNoneFalse414.00
3199834109998None3.4.5Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 8 WAY ---- with all lead and liftsMtr261.0261.01.0FalseNoneNoneFalseNoneFalse261.00
3199835109998None3.4.6Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 10-12 WAY ---- with all lead and liftsEach319.0319.05.0FalseNoneNoneFalseNoneFalse1595.00
3199836109998None3.5.1Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 1 TO 2 MODULE ---- with all lead and liftsEach137.0137.03.0FalseNoneNoneFalseNoneFalse411.00
3199837109998None3.5.5Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.8 MOUDULE ---- with all lead and liftsEach284.0284.01.0FalseNoneNoneFalseNoneFalse284.00
3199838109998None3.5.6Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 10-12 MOUDULE ---- with all lead and liftsEach344.0344.02.0FalseNoneNoneFalseNoneFalse688.00
3199839109998None3.6.1Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 6A one way switch ---- with all lead and liftsEach102.0102.016.0FalseNoneNoneFalseNoneFalse1632.00
3199840109998None3.6.4Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. stepped fan regulator two moudule ---- with all lead and liftsEach357.0357.02.0FalseNoneNoneFalseNoneFalse714.00
3199841109998None3.6.7Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.16A one way switch ---- with all lead and liftsEach180.0180.06.0FalseNoneNoneFalseNoneFalse1080.00
3199842109998None3.6.9Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.32A DP switch ---- with all lead and liftsEach326.0326.02.0FalseNoneNoneFalseNoneFalse652.00
3199843109998None3.6.10Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 6/16A universal socket ---- with all lead and liftsEach236.0236.04.0FalseNoneNoneFalseNoneFalse944.00
3199844109998None3.6.3Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 6 threeway socket ---- with all lead and liftsEach171.0171.04.0FalseNoneNoneFalseNoneFalse684.00
3199845109998None11.3.2Supplying of .feet -PVC Batten with integrated LED tube W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V@ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED LIGHT FITTING ---- with all lead and liftsEach690.0690.08.0FalseNoneNoneFalseNoneFalse5520.00
3199846109998None5.7.2Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers. 32AMPS ---- with all lead and liftsEach241.0241.01.0FalseNoneNoneFalseNoneFalse241.00
3199847109998None5.18.1Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 a SP ---- with all lead and liftsEach415.0415.01.0FalseNoneNoneFalseNoneFalse415.00
3199848109998None5.18.4Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 A DP ---- with all lead and liftsEach739.0739.01.0FalseNoneNoneFalseNoneFalse739.00
3199849109998None5.19.6Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure. II Double door ---- with all lead and liftsEach1524.01524.01.0FalseNoneNoneFalseNoneFalse1524.00
3199850109998None12.56Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40 mm dia 2.90 mm thick GI pipe 2.5m long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150 mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12 mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia. ---- with all lead and liftsNo3510.03510.01.0FalseNoneNoneFalseNoneFalse3510.00
3199851109998None6.3.2Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system. 56 sweep(1400mm) Regular ---- with all lead and liftsEach3031.03031.02.0FalseNoneNoneFalseNoneFalse6062.00
3199852109998None5.6.1Supply and fixing polished wood board made of not less than 15mm thick plank on both sides of not more than 2 pieces and fixing the same to the wall using tapered inverted wooden plugs screws. 8*6*1.5 ---- with all lead and liftsEach87.087.01.0FalseNoneNoneFalseNoneFalse87.00
3199853109998None5.6.4Supply and fixing polished wood board made of not less than 15mm thick plank on both sides of not more than 2 pieces and fixing the same to the wall using tapered inverted wooden plugs screws. 12*12*2 ---- with all lead and liftsEach181.0181.01.0FalseNoneNoneFalseNoneFalse181.00
3199854109998None13.7.1Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling / rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clamps. on wall/ceiling/Rafter ---- with all lead and liftsEach122.0122.05.0FalseNoneNoneFalseNoneFalse610.00
3199855109998None13.1Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing S hook with fan regulator to the existing board together with supplying and fixing 5 A. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring. ---- with all lead and liftsEach171.0171.02.0FalseNoneNoneFalseNoneFalse342.00
3199856109998None1.9.1Supplying PVC flexible conduit pipe . mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300 mm using NF screws and on either end of the pipe terminated completely. 20mm ---- with all lead and liftsMtr19.019.02.0FalseNoneNoneFalseNoneFalse38.00
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17169803630000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17169803630000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17169803630001NoneNoneELIGIBILITYBidder shall pay Contract Management Module processing fees of 0.025% of the contact value (Min Rs.500/- & Max Rs.7500/-) soon after contract has been issued to bidder.None
17169803630000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17169803630000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
17169803630001NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17169803630000NoneNoneELIGIBILITYTotal value of civl engineering works executed and payments received in the last five years (year-wise)None
17169803630000NoneNoneELIGIBILITYList of existing commitments and ongoing workNone
17169803630000NoneNoneELIGIBILITYList of works for which tenders already submittedNone
17169803630000NoneNoneELIGIBILITYBanker DetailsNone
17169806430000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
17169806510000NoneNoneELIGIBILITYThe bidder is required to ensure browser compatibility of the computer well in advance to the last date and time for receipt of tenders. The departments shall not be responsible for non-accessibility of KPPP portal due to internet connectivity issues and technical glitches at bidders endNone
17169806570000NoneNoneELIGIBILITYConditional tenders will not be accepted.None
17169806650000NoneNoneELIGIBILITYAs per karnataka state government order LD/300/LET/2006 Bangalore dated 01-01-2007 and Govt letter No.PW/134/BMS /2007/dated 27-07-2007, a sum amounting to 1% of the bill amount will be deducted towards constructions labour welfare fund.None
17169806720000NoneNoneELIGIBILITYRoyalty on construction materials and other taxes will be deducted as per prevailing Govt ordersNone
17169806780000NoneNoneELIGIBILITYTotal value of civl engineering works executed and payments received in the last five years (year-wise)None
17169806920000NoneNoneELIGIBILITYAll the documents to be uploaded shall be neatly scanned and the documents scanned shall be in original.None
17169807200000NoneNoneELIGIBILITYQualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awardedNone
17169807290000NoneNoneELIGIBILITYAny discrepancies observed in the documents uploaded by the tenderer the tender shall liable to rejected.None
17169807370000NoneNoneELIGIBILITYAll the Formats prescribed in the bid documents shall be filled in complete manner. ( section 3 & 4 of the bid document ) and shall be uploaded properly, signed by Tenderer . Necessary Certificates shall be uploaded along with the formats wherever required. General documents Section can be used for this purpose.None
17169807450000NoneNoneELIGIBILITYEarnest Money Deposit will have to be in any one of the forms as per the instructions in the financial bid document and shall have to be valid for 45 days beyond the validity of the tender.None
17169807520000NoneNoneELIGIBILITYTenderers are requested to read the Bid Documents before submission of their bid.None
17169807620000NoneNoneELIGIBILITYDepartment will not supply any materials.None
17169807680000NoneNoneELIGIBILITYThe cost of the Tender form shall not be refundable.None
17169807740000NoneNoneELIGIBILITYThe employer is not responsible for any delay in accessing KPPP Portal.None
17169808180000NoneNoneELIGIBILITYThe Employer reserves the rights reject one or all tender without assigning any reasons.None
17169808330000NoneNoneELIGIBILITYFurther particulars, if any, required by the Contractor can be had from the office of the Executive Engineer, PWD Division Chikodi during office hours on all working days. It may be noted that if any of the dates mentioned above happened next working day will holds good in lieu of the dates mentionedNone
17169808410000NoneNoneELIGIBILITYThe Tenderer are should be present during opening of the tender and also submit the uploaded documents duly attested by the Gazetted Officer not below the Rank of Executive EngineerNone
17169808490000NoneNoneELIGIBILITYContractors should Registered in KPWD and copy should be uploaded in KPPP Attested by the Gazzeted officers not below the rank of Executive Engineer.None
17169808560000NoneNoneELIGIBILITYGST shall be paid to the tendered amount seperately.None
17169808650000NoneNoneELIGIBILITYThe Increase in G.S.T shall not be paid in the extended period of Contract for which the contractor alone is responsible for delay as determined by the authority while granting the extension of time.None
17169808730001NoneNoneELIGIBILITYWork Completion/Execution Period : 3 months Including Mansoon.None
17169808810001NoneNoneELIGIBILITYThe Project Completion period is 3 months and the Tenderer should maintain work during the defect liability period, which is (1) One year after successful completion of the work.None
17169808890000NoneNoneELIGIBILITYDifference amount should submit at the time of Agreement.None
17169808970000NoneNoneELIGIBILITYFinancial turover of previous years shall be given a weight of 10% per year to bring them to the price level of the 2024-25 in the Technical Qualification Criteria mentioned in the next sectionNone
17169809620000NoneNoneELIGIBILITYIf no bid received auto extension will be done by KPPP Portal itself for 2 daysNone
17169809690000NoneNoneELIGIBILITYThe cost of steel reinforcement & formwork shall be paid separately for concrete items onlyNone
17169809760000NoneNoneELIGIBILITYUnique Document Identification Number (UDIN) form practicing Chartered Account is preferredNone
17169810090000NoneNoneELIGIBILITYThe Tenderer shall achieved in at least two financial years an average annual financial turnover from financial year 2019-20 to 2023-24 of Rs.14.52 Lakhs (not less than the estimated cost under this contract)None
17169810390000NoneNoneELIGIBILITYThe Tenderer shall obtain similar the workdone certificate from financial year 2019-20 to 2023-24 (50% of the Amount Put to Tender i.e., Rs.7.26 Lakhs) in the prescribed format from the Competent Authority not below the rank of Executive Engineer(District Level Officer)and scan the Original Certificate and attach the scanned file to the Bid.None
17169810630000NoneNoneELIGIBILITYThe EMD of Rs.36,500.00/- shall be paid in full through e-payment in favour of Executive Engineer, PWD, Chikodi Dn, ChikodiNone
preQualCriterionListNone
technicalCriterionListNone
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Contractors KPWD Civil Registration CertificateTrueTechnical Bid
Annual Turn Over Certificate from 2019-20 to 2023-24TrueTechnical Bid
Similar Financial Work Done Certificate 50percentage of APTTrueTechnical Bid
Ongoing work detailsTrueTechnical Bid
GST RegistratationTrueTechnical Bid
Any other related documentsTrueTechnical Bid
UDIN form practicing Chartered Account is preferredTrueTechnical Bid
tenderWorkLocationList
tenderAddressNone
tenderRecallDTONone