createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1716967237501
version11
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee2620.00
emd200000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose13-06-2024 16:00:00
tenderQueryClose04-06-2024 16:00:00
technicalBidOpen14-06-2024 16:30:00
publishedDate30-05-2024 16:22:25
publishedByPostEWHFWD_CE_CEOFF_BNG
publishedByUserKPE16838 - BALEKATTE KUMARASWAMY PAVITHRA
bidValidityPeriod90
noOfCalls2
preBidMeetingDate05-06-2024 11:00:00
preBidMeetingYnTrue
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnTrue
percentageRateTypeTextNone
contactPersonTechnical Assistant
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumber08029557023
mobileNumber9448653156
tenderSupplierListNone
tenderSchedule
createdTs1716967237504
version26
createdDateNone
modifiedDateNone
tenderNumberEWHFWD/2023-24/BD/WORK_INDENT47/CALL-2
titleCONSTRUCTION OF DISTRICT INTEGRATED PUBLIC HEALTH LABORATORY ON EXISTING TRAUMA CENTRE AT SECOND FLOOR BUILDING AT WENLOCK MANGALURU
descriptionCONSTRUCTION OF DISTRICT INTEGRATED PUBLIC HEALTH LABORATORY ON EXISTING TRAUMA CENTRE AT SECOND FLOOR BUILDING AT WENLOCK MANGALURU
categoryWORKS
categoryTextWorks
ecv10475708.89
deptNameEngineering Wing of Health and Family Welfare Department
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnFalse
location3521
locationNameEWHFWD Chief Engineer Office Bengaluru
provisionalAmount11100000.0
groupOverheadTotal0.0
fileNumberKHSDRP/AEEMNG/IPHL/MANGALURU
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17169672380001NoneNoneBuildingsGround Floor -Civil work985616.04
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3197945109935None1.14.1 v-1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Cum134.8134.822.32FalseNoneNoneFalseNoneFalse3008.7360
3197946109935None4.1 v-2Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications. ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Sqm155.95155.958.84FalseNoneNoneFalseNoneFalse1378.5980
3197947109935None1.9 v-1Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Cum351.55351.5522.32FalseNoneNoneFalseNoneFalse7846.5960
3197948109935None2.1.3 v-1Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Cum7915.067915.060.97FalseNoneNoneFalseNoneFalse7677.60820
3197949109935None2.2.3 v-1Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm and down size graded crushed coarse aggregates ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Cum9043.559043.553.83FalseNoneNoneFalseNoneFalse34636.79650
3197950109935None2.5.2 v-1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.For Lift Wall ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Cum9948.089948.083.24FalseNoneNoneFalseNoneFalse32231.77920
3197951109935None2.5.2 v-1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.For RCC Beams ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Cum14469.9314469.931.09FalseNoneNoneFalseNoneFalse15772.22370
3197952109935None2.5.2 v-1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.For RCC Columns ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Cum15374.315374.30.29FalseNoneNoneFalseNoneFalse4458.5470
3197953109935None2.11a v-1Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.Buildings ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Tonne118226.37118226.371.21FalseNoneNoneFalseNoneFalse143053.90770
3197954109935None6.32 v-2Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Sqm1731.31731.333.95FalseNoneNoneFalseNoneFalse58777.6350
3197955109935None8.4.2 v-2Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Sqm412.34412.3436.51FalseNoneNoneFalseNoneFalse15054.53340
3197956109935None8.51 v-2Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Sqm132.16132.1636.51FalseNoneNoneFalseNoneFalse4825.16160
3197957109935None8.5.2 v-2Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Sqm461.24461.24765.77FalseNoneNoneFalseNoneFalse353203.75480
3197958109935None8.39 v-2Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Sqm167.84167.8436.51FalseNoneNoneFalseNoneFalse6127.83840
3197959109935None8.32 v-2Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Sqm206.17206.17765.77FalseNoneNoneFalseNoneFalse157878.80090
3197960109935None19.55 v-2Dismantalling old plaster or skirting racking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground to the appropriate disposal area as per direction of engineer in charge. ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Sqm48.8948.89729.26FalseNoneNoneFalseNoneFalse35653.52140
3197961109935NoneJobThe Tendorer (Agency ) should arrange to obtain (Get) , detailed Architectural drawings and elevations, Structural designs and drawings including Soil exploration & proof checking by IISC /IIT/NIT only as decided by the Department and the same has to be furnished to the Department for approval and providing consultancy for Architectural designs & drawings, elevation, 3D view, MFP design and Drawings, Internal and External Electrical services including electrical infrastructure , interior layout and liaison with other department and approval of pollution control board and allied works etc., and any other drawings related to this project and 6 sets of as built drawings should be submitted to the employer. The Consultancy Fees which is included as an item in schedule B shall be paid on prorate basis of the main work or by negotiation with the employer. - etc., complete as per the specification and Engineer-in-charge of work ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Job104030.0104030.01.0FalseNoneNoneFalseNoneFalse104030.00
17169672380000NoneNoneBuildingsFirst Floor- Civil work731026.6
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3197962109936None2.5.2 v-1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.For Lift Columns ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Cum15528.0515528.051.15FalseNoneNoneFalseNoneFalse17857.25750
3197963109936None2.5.2 v-1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.For RCC Beams ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Cum14614.6314614.631.09FalseNoneNoneFalseNoneFalse15929.94670
3197964109936NoneV-1 18 2.11aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.Buildings ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Tonne119408.63119408.630.47FalseNoneNoneFalseNoneFalse56122.05610
3197965109936None6.32 v-2Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Sqm1748.611748.6136.51FalseNoneNoneFalseNoneFalse63841.75110
3197966109936None8.4.2 V-2Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Sqm416.46416.4636.51FalseNoneNoneFalseNoneFalse15204.95460
3197967109936None8.10 v-2Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Sqm281.65281.6511.51FalseNoneNoneFalseNoneFalse3241.79150
3197968109936None8.51 v-2Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Sqm200.22200.2248.02FalseNoneNoneFalseNoneFalse9614.56440
3197969109936None8.39 v-2Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Sqm169.52169.5211.51FalseNoneNoneFalseNoneFalse1951.17520
3197970109936None8.32 v-2Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Sqm208.23208.23765.77FalseNoneNoneFalseNoneFalse159456.28710
3197971109936None19.55 v-2Dismantalling old plaster or skirting racking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground to the appropriate disposal area as per direction of engineer in charge ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Sqm49.3849.38629.26FalseNoneNoneFalseNoneFalse31072.85880
3197972109936None8.5.2 V-2Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( Outside) ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Sqm465.85465.85765.77FalseNoneNoneFalseNoneFalse356733.95450
17169672380001NoneNoneBuildingsSecond Floor-Civil work6915789.36
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3197973109937None19.7.3 v-2Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge.In cement mortar ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Cum1387.121387.126.57FalseNoneNoneFalseNoneFalse9113.37840
3197974109937None2.5.2 v-1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.RCC Beams & Lintels ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Cum14759.3314759.3318.87FalseNoneNoneFalseNoneFalse278508.55710
3197975109937None2.5.2 v-1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.For RCC Roof Slab ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Cum13836.8713836.8752.18FalseNoneNoneFalseNoneFalse722007.87660
3197976109937None2.5.2 v-2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.For RCC Colums ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Cum15681.7915681.7910.26FalseNoneNoneFalseNoneFalse160895.16540
3197977109937None2.5.2 v-1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.For RCC Chajjas ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Cum13375.6513375.651.36FalseNoneNoneFalseNoneFalse18190.8840
3197978109937None2.11a-v-1Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.Buildings ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Tonne120590.9120590.910.23FalseNoneNoneFalseNoneFalse1233644.9070
3197979109937None5.7 v-2Providing and constructing laterite size stone masonry including cost and conveyance of all materials curing etc complete as per specification. I.S. 3620/1979 having compressive strength not less then 3.5 N/mm2 for saturated dry samples for superstructure in CM 1:6. ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Cum9105.969105.9628.26FalseNoneNoneFalseNoneFalse257334.42960
3197980109937None6.32 v-2Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Sqm1765.921765.92194.71FalseNoneNoneFalseNoneFalse343842.28320
3197981109937None6.34 v-2Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. SECOND FLOOR Male & Female toilet Male & Female toilet Deduction D3 ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Sqm1488.231488.2341.22FalseNoneNoneFalseNoneFalse61344.84060
3197982109937None12.93.3 V-2Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately)Size 62 x 150mm ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.m1087.861087.8689.1FalseNoneNoneFalseNoneFalse96928.3260
3197983109937None12.51 v-2Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.No1369.61369.612.0FalseNoneNoneFalseNoneFalse16435.20
3197984109937None10.6.3 v-2Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Each80.8880.8872.0FalseNoneNoneFalseNoneFalse5823.360
3197985109937None12.57.4 v-2Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 35 mm thick both side Teak ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Sqm6109.286109.2828.35FalseNoneNoneFalseNoneFalse173198.0880
3197986109937None12.90 v-2Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Sqm9077.659077.6520.25FalseNoneNoneFalseNoneFalse183822.41250
3197987109937None12.85 v-2Providing & fixing of louvered ventilator made out of multi chambered UPVC Matching to RAL 9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Sqm7709.47709.42.7FalseNoneNoneFalseNoneFalse20815.380
3197988109937None11.34B v-2Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings/wooden frames with raul plugs screws etc. ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Kg246.69246.69481.95FalseNoneNoneFalseNoneFalse118892.24550
3197989109937None12.93.2 v-2 Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door window/Clerestory windows & other Frames Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer InCharge. (Fixtures shall be paid for separately) Size 62x125mm" ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.m1029.91029.920.4FalseNoneNoneFalseNoneFalse21009.960
3197990109937None12.94.1 v-2Providing and fixing factory made Green certified, Anti Termite, UV resistant,high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately)30mm thickness. ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Sqm4697.894697.897.56FalseNoneNoneFalseNoneFalse35516.04840
3197991109937None12.59 v-2Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.No1501.711501.7112.0FalseNoneNoneFalseNoneFalse18020.520
3197992109937None11.25.2 v-2 Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Kg183.33183.33120.96FalseNoneNoneFalseNoneFalse22175.59680
3197993109937None8.4.2 v-2Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( Inside) ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Sqm420.59420.59824.21FalseNoneNoneFalseNoneFalse346654.48390
3197994109937None8.10 v-2Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Sqm284.43284.43269.41FalseNoneNoneFalseNoneFalse76628.28630
3197995109937None8.51 v-2Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Sqm134.8134.81093.62FalseNoneNoneFalseNoneFalse147419.9760
3197996109937None8.9 v-2 Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( Outside) ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Sqm518.99518.99419.2FalseNoneNoneFalseNoneFalse217560.6080
3197997109937None8.79 v-2 Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove. ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.m70.170.158.2FalseNoneNoneFalseNoneFalse4079.820
3197998109937None9.17.2 v-2 Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete.).Size of Tile 600x600 mm ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Sqm1583.941583.94309.5FalseNoneNoneFalseNoneFalse490229.430
3197999109937None9.29 v-2 Providing and laying flooring and steps fine dressed granite stone slabs 40 mm thick on cement mortar bed 1:6, 25 mm thick, and pointed with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Sqm5804.635804.6318.54FalseNoneNoneFalseNoneFalse107617.84020
3198000109937None15.7 v-2 Providing and supplying crystalline integral concrete waterproofing admixture that waterproofs concrete by forming crystals deep in the pores, capillaries and microcracks of the concrete, self-seal waterproofing compound to bridge shrinkage cracks upto 0.5mm in width & resist hydro-static pressure upto 16bar for both positive & negative pressure confirming to DIN 1048 part 5 for 56% reduction in depth of penetration against control, resistance to chloride penetration confirming to ASTM C 1202 with 64% improvement against control & protecting steel re-inforcement against corrosion mixed @ 1% by weight of cementitious content in concrete. ie., integral crystaline waterproofing admix @ 0.5 kg/bag of cement. (For calculation purpose 320 kg of Cement for M-20 grade of Concrete is considered in the analysis) ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Sqm829.04829.0432.33FalseNoneNoneFalseNoneFalse26802.86320
3198001109937None9.11 v-2 Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Sqm1198.41198.432.33FalseNoneNoneFalseNoneFalse38744.2720
3198002109937None9.39 v-2 Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Sqm1953.31953.3106.01FalseNoneNoneFalseNoneFalse207069.3330
3198003109937None8.39 v-2Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Sqm171.2171.21093.62FalseNoneNoneFalseNoneFalse187227.7440
3198004109937None8.32 v-2 Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Sqm210.29210.29419.2FalseNoneNoneFalseNoneFalse88153.5680
3198005109937None8.40 v-2 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per dir ections of Engineer-in-charge. ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Sqm155.02155.0222.95FalseNoneNoneFalseNoneFalse3557.7090
3198006109937None8.34.1 v-2Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Sqm71.4571.4568.04FalseNoneNoneFalseNoneFalse4861.4580
3198007109937None8.47 v-2Polishing on wood work with ready mixed wax polish of approved brand and manufacture : New work to give an even surface including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Sqm181.98181.9868.04FalseNoneNoneFalseNoneFalse12381.91920
3198008109937None12.92 v-2 Providing& fixing of Openable door made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPV(Thermo Plastic Vulcanized) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the openable frame. The frame having overall size of 60mm x 55mm with GI reinforcement of 1mm thickness and openable sash with overall size of 60mm x 102mm and GI reinforcement of 2mm thickness. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 34 mm. Windows shall be provided with 6mm plain float glass, Standard hardware with 2D/3D hinge & Multi point locking system with Handle. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size. 900mm x 2400mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Sqm8418.468418.462.4FalseNoneNoneFalseNoneFalse20204.3040
3198009109937None12.91 v-2 Providing& fixing of Openable window made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPV(Thermo Plastic Vulcanized) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the openable frame. The frame having overall size of 60mm x 55mm with GI reinforcement of 1mm thickness and openable sash with overall size of 60mm x 75mm and GI reinforcement of 1.5mm thickness. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 34 mm. Windows shall be provided with 5mm plain float glass, Standard hardware with friction hinge & Multi point locking system with Handle. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 900mm x 1819mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Sqm8171.778171.777.2FalseNoneNoneFalseNoneFalse58836.7440
3198010109937NoneSR 2018-19.324 39.4Providing and fixing storage unit of 0. 75m depth made out of 19mm thick commercial ply vertical support finished in approved 1.00mm laminate with 12mm thick ply packing internally finished with enamel paint of approved colour and shade shelves shall be formed out of 19mm ply finished with enamel paint of approved shade and colour and 19mm thick shutters formed out of 19mm thick ply finished with 1.00mm thick laminate of approved shade and colour etc., complete the rate includes cost of all materials, labour charges, complete as per specification. - - - etc., complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work. ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Sqm17618.7817618.7824.72FalseNoneNoneFalseNoneFalse435536.24160
3198011109937None9.21.2 v-2 Providing and laying Vitrified tiles in floor with different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).Size of Tile 600x600 mm ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Sqm1668.861668.8618.54FalseNoneNoneFalseNoneFalse30940.66440
3198012109937None10.1.7 v-5Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: PVC pipes 110mm dia., 6 kg/sqcm & class 3 ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Mtr554.04554.0442.0FalseNoneNoneFalseNoneFalse23269.680
3198013109937NoneV-2 152 15.12Newly Constructed Roof/Podium with PU Waterproof coating - Above 500 m2 Providing and Applying single component Polyurethane based cold applied seamless waterproofing coating to the RCC surface like Roof & Podium area applied @ 2.4kg/m2 in 3 coats to achieve 1.5mm DFT, including a prime coat of solvent free, medium viscous, epoxy primer @0.2L/m2 and protection with 120gsm Geo-textile over the 7 days cured waterproofing membrane. The Waterproofing material shall have Solids 85%, Tensile strength greater than 2 Mpa as per ASTM D 412, Elongation at break greater than 400% confirms to ASTM C 1305 for crack bridging ability (no cracks up to 3.2mm) Shore A Hardness greater than 55 as per ASTM D 2240, Adhesion to peel after water immersion as per ASTM C 794 at 5.2N. Resistance to root penetration as per UNE CN/ TS 14416. The finished cost to include surface preparation, making coving of 50 mm X 50mm at all right angles of wall Junction with Polymer Repair Mortar and lay 60gsm Geo-textile over the angle fillet when the first coat in still wet, treatment of cracks completely as per specification ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Sqm1570.461570.46376.0FalseNoneNoneFalseNoneFalse590492.960
17169672380000NoneNoneBuildingsLift room third floor-Civil work208374.16
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3198014109938None2.5.2 v-1 Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates For RCC Columns ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Cum15528.0515528.051.15FalseNoneNoneFalseNoneFalse17857.25750
3198015109938None2.5.2 v-1 Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.For RCC Beams ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Cum14614.6314614.631.09FalseNoneNoneFalseNoneFalse15929.94670
3198016109938NoneV-1 18 2.11aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.Buildings ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.t119408.63119408.630.47FalseNoneNoneFalseNoneFalse56122.05610
3198017109938None6.32 v-2Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Sqm1748.611748.6136.51FalseNoneNoneFalseNoneFalse63841.75110
3198018109938None8.4.2 v-2 Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( Inside) ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Sqm416.46416.4636.51FalseNoneNoneFalseNoneFalse15204.95460
3198019109938None8.10 v-2 Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Sqm281.65281.6511.51FalseNoneNoneFalseNoneFalse3241.79150
3198020109938None8.51 v-2 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Sqm200.22200.2248.02FalseNoneNoneFalseNoneFalse9614.56440
3198021109938None8.5.2 v-2Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( Outside) ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Sqm465.85465.8536.51FalseNoneNoneFalseNoneFalse17008.18350
3198022109938None8.39 v-2Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Sqm169.52169.5211.51FalseNoneNoneFalseNoneFalse1951.17520
3198023109938None8.32 v-2Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Sqm208.23208.2336.51FalseNoneNoneFalseNoneFalse7602.47730
17169672380000NoneNoneBuildingsWater supply and sanitary works282963.68
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3198024109939None14.28.2.2 v-2 Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. 40mm dia pipes, ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Each124.02124.0212.0FalseNoneNoneFalseNoneFalse1488.240
3198025109939None16.7.4 v-5 Providing and fixing normal gauge polythene pipes of approved quality with special flange compression type fittings of approved make including trench excavation and refilling etc. for EXTERNAL WORKS with: 50mm nominal bore pipes, ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.m187.38187.3815.0FalseNoneNoneFalseNoneFalse2810.70
3198026109939None657 v-5Providing and fixing PVC pipe - OD 75mm and 6 Kg/sqcm, ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.m165.81165.8140.0FalseNoneNoneFalseNoneFalse6632.40
3198027109939None647 v-5 Providing and fixing PVC pipe - OD 110mm and 6 Kg/sqcm, ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.m343.75343.7530.0FalseNoneNoneFalseNoneFalse10312.50
3198028109939None13.47 v-2 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 75mm diameter ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.m265.56265.5630.0FalseNoneNoneFalseNoneFalse7966.80
3198029109939None13.48 v-2Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 100mm diameter ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.m392.28392.2820.0FalseNoneNoneFalseNoneFalse7845.60
3198030109939None14.31 v-2 Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Each1644.61644.64.0FalseNoneNoneFalseNoneFalse6578.40
3198031109939None13.16 v-2 Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.No835.78835.7810.0FalseNoneNoneFalseNoneFalse8357.80
3198032109939None14.3.1 v-2 Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C pan with ISI marked white solid plastic seat and lid ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Each8057.198057.192.0FalseNoneNoneFalseNoneFalse16114.380
3198033109939None13.15 v-2 Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.No977.32977.325.0FalseNoneNoneFalseNoneFalse4886.60
3198034109939None14.11.2 v-2 Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : Size 600x450x200 mm ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Each6850.76850.710.0FalseNoneNoneFalseNoneFalse68507.00
3198035109939None14.7.1 v-2 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15mm C.P. brass pillar taps ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Each4154.634154.633.0FalseNoneNoneFalseNoneFalse12463.890
3198036109939None14.22 a v-2Providing and fixing CP Brass 32mm size Bottle Trap of approved quality& make and as per the direction of Engineer-in-charge. ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Each1091.911091.916.0FalseNoneNoneFalseNoneFalse6551.460
3198037109939None978 v-2 Providing and fixing Unplasticised P.V.C.connection pipe with brass union 30 cm long 15 mm bore ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Each51.2351.2310.0FalseNoneNoneFalseNoneFalse512.30
3198038109939None14.37.1 v-2Bottle trap 31mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 260g ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Each412.5412.526.0FalseNoneNoneFalseNoneFalse10725.00
3198039109939None13.2.1 v-2 Providing and fixing brass bib cock of approved quality 15 mm nominal bore ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.No385.54385.5410.0FalseNoneNoneFalseNoneFalse3855.40
3198040109939None13.32.1 v-2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.15 mm nominal dia Pipes ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.m416.54416.5420.0FalseNoneNoneFalseNoneFalse8330.80
3198041109939None13.32.2 v-2 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.20 mm nominal dia Pipes ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.m510.9510.930.0FalseNoneNoneFalseNoneFalse15327.00
3198042109939None13.33.2 v-2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 20 mm nominal dia Pipes ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.m292.52292.5230.0FalseNoneNoneFalseNoneFalse8775.60
3198043109939None13.33.3 v-2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 25 mm nominal dia Pipes ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.m399.02399.0220.0FalseNoneNoneFalseNoneFalse7980.40
3198044109939None13.4.1 v-2Providing and fixing Brass full way valve with C.I. wheel (screwed end) 25 mm dia ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.No740.07740.078.0FalseNoneNoneFalseNoneFalse5920.560
3198045109939None16.9 v-5Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover. ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Each7352.177352.175.0FalseNoneNoneFalseNoneFalse36760.850
3198046109939None13.34 v-2 Providing and placing on terrace (at all floor levels) polyethylene water storage tank,IS:12701 marked,with cover and suitable locking arrangement and making necessary holes for inlet,outlet and overflow pipes but without fittings and the base support for tank. ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Ltr12.1312.132000.0FalseNoneNoneFalseNoneFalse24260.00
17169672380000NoneNoneBuildingsInternal Electrification1351939.05
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3198047109940None2.2.1 v-6 Point wiring using Copper wire without switch. "Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet." Short point up to 3Mtr from tapping point to out let via switch ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Point355.51355.5125.0FalseNoneNoneFalseNoneFalse8887.750
3198048109940None2.2.2 v-6Point wiring using Copper wire without switch. "Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet." Medium point above 3Mtr up to 6Mtr from tapping point to out let via switch ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Point500.89500.8934.0FalseNoneNoneFalseNoneFalse17030.260
3198049109940None2.2.3 v-6Point wiring using Copper wire without switch. "Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet." Long point above 6Mtr up to 10Mtr from tapping point to out let via switch ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Point733.49733.4940.0FalseNoneNoneFalseNoneFalse29339.60
3198050109940None2.2.4 v-6Point wiring using Copper wire without switch. "Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet." Two outlet in a row, above 3Mtr up to 6Mtr from tapping point to out let via switches ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Point894.72894.726.0FalseNoneNoneFalseNoneFalse5368.320
3198051109940None3.4.1 v-6Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 1-2Way ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Each182.38182.3820.0FalseNoneNoneFalseNoneFalse3647.60
3198052109940None3.4.4 v-6Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 4-5Way ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Each233.92233.928.0FalseNoneNoneFalseNoneFalse1871.360
3198053109940None3.4.4 v-6Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 6Way ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Each290.75290.754.0FalseNoneNoneFalseNoneFalse1163.00
3198054109940None3.4.5 v-6Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 8 Way ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Each344.94344.9416.0FalseNoneNoneFalseNoneFalse5519.040
3198055109940None3.4.6 v-6 Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 10-12Way ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Each421.59421.5935.0FalseNoneNoneFalseNoneFalse14755.650
3198056109940None3.5.1 v-6 Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 1 to 2 Module ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Each181.06181.0620.0FalseNoneNoneFalseNoneFalse3621.20
3198057109940None3.5.3 v-6 Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 4 Module ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Each231.28231.288.0FalseNoneNoneFalseNoneFalse1850.240
3198058109940None3.5.4 v-6Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 6 Module ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Each309.25309.254.0FalseNoneNoneFalseNoneFalse1237.00
3198059109940None3.5.5 v-6 Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 8 Module ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Each375.33375.3316.0FalseNoneNoneFalseNoneFalse6005.280
3198060109940None3.5.6 v-6Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 10-12 Module ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Each454.63454.6335.0FalseNoneNoneFalseNoneFalse15912.050
3198061109940None3.6.1 v-6 Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps one way Switch ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Each134.8134.8184.0FalseNoneNoneFalseNoneFalse24803.20
3198062109940None3.6.3 v-6Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps 3way socket ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Each219.39219.3979.0FalseNoneNoneFalseNoneFalse17331.810
3198063109940None3.6.4 v-6Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Stepped Fan Regulator. ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Each471.81471.8124.0FalseNoneNoneFalseNoneFalse11323.440
3198064109940None3.6.8 v-6Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 16Amps one way switch ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Each237.89237.895.0FalseNoneNoneFalseNoneFalse1189.450
3198065109940None3.6.9 v-6 Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 32Amps DP switch ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Each430.84430.8413.0FalseNoneNoneFalseNoneFalse5600.920
3198066109940None3.6.10 v-6 Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6/16Amps universal socket ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Each311.9311.918.0FalseNoneNoneFalseNoneFalse5614.20
3198067109940None1.13 v-6 Supplyin and Fixing Metal Fan Box with Round Hook. ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.No154.63154.6324.0FalseNoneNoneFalseNoneFalse3711.120
3198068109940None1.2.1 v-6 Concealed Conduit System Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 19/20mm dia 2mm thick ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Mtr87.2387.23800.0FalseNoneNoneFalseNoneFalse69784.00
3198069109940None1.2.2 v-6 Concealed Conduit System Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 25mm dia 2mm thick ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Mtr103.08103.08920.0FalseNoneNoneFalseNoneFalse94833.60
3198070109940None1.2.3 v-6Concealed Conduit System Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 32mm dia 2.5mm thick ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Mtr136.12136.12100.0FalseNoneNoneFalseNoneFalse13612.00
3198071109940None1.3.1 v-6 Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 19/20mm dia 2mm thick ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Mtr89.8789.87400.0FalseNoneNoneFalseNoneFalse35948.00
3198072109940None1.3.2 v-6 Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 25mm dia 2mm thick ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Mtr104.41104.41250.0FalseNoneNoneFalseNoneFalse26102.50
3198073109940None1.3.3 v-6 Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 32mm dia 2.5mm thick ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Mtr130.84130.8450.0FalseNoneNoneFalseNoneFalse6542.00
3198074109940None2.3.2 v-6 Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments." 1.5 sqmm ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Mtr34.3634.36400.0FalseNoneNoneFalseNoneFalse13744.00
3198075109940None2.3.3 v-6 Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments." 2.5 sqmm ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Mtr55.5155.51800.0FalseNoneNoneFalseNoneFalse44408.00
3198076109940None2.3.4 v-6 Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments." 4 sqmm ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Mtr83.2683.26500.0FalseNoneNoneFalseNoneFalse41630.00
3198077109940None2.3.5 v-6 Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments." 6 sqmm ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Mtr121.59121.59300.0FalseNoneNoneFalseNoneFalse36477.00
3198078109940None2.3.6 v-6 Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments." 10 sqmm ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Mtr220.71220.71200.0FalseNoneNoneFalseNoneFalse44142.00
3198079109940None5.19.4 v-6 Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I phase I single door with powder coated painting. Made out of 14 SWG MS enclosure I- Single Door 12 Way SP & N ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Each2462.142462.141.0FalseNoneNoneFalseNoneFalse2462.140
3198080109940None5.19.11 v-6 Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I phase I single door with powder coated painting. Made out of 14 SWG MS enclosure III - Double Door 4 Way TPN DB ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Each5336.625336.621.0FalseNoneNoneFalseNoneFalse5336.620
3198081109940None5.19.12 v-6Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I phase I single door with powder coated painting. Made out of 14 SWG MS enclosure III - Double door 6 Way TP & N ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Each6528.76528.71.0FalseNoneNoneFalseNoneFalse6528.70
3198082109940None5.18.1 v-6Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32Amps SP ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Each548.46548.4640.0FalseNoneNoneFalseNoneFalse21938.40
3198083109940None5.18.8 v-6Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 40 A TPN ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Each4022.954022.951.0FalseNoneNoneFalseNoneFalse4022.950
3198084109940None5.18.9 v-6Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 50-63Amps TPN ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Each4081.14081.11.0FalseNoneNoneFalseNoneFalse4081.10
3198085109940None5.18.4 v-6Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32 A DP ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Each976.66976.661.0FalseNoneNoneFalseNoneFalse976.660
3198086109940None5.20.1 v-6 Supplying, fixing and wiring Residual current circuit breaker (RCCB)240/450V upto 300mA sensitivity on existing wood/ panel board. " 32-40 A 2 pole ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Each6025.176025.172.0FalseNoneNoneFalseNoneFalse12050.340
3198087109940None32.09 v-6LT UG CABLES "1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 " 3.5 core 35 sqmm ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Km203608.34203608.340.1FalseNoneNoneFalseNoneFalse20360.8340
3198088109940None21.06 v-6Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff" 35 sqmm to 95 sqmm ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Km41153.341153.30.1FalseNoneNoneFalseNoneFalse4115.330
3198089109940None63.02 v-6Supplying and fiixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) 32mm dia ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Each125.55125.558.0FalseNoneNoneFalseNoneFalse1004.40
3198090109940None59.02 v-6 Heavy Duty Copper Terminal Long Barrel 35 sqmm Long Barrel ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Each42.2942.298.0FalseNoneNoneFalseNoneFalse338.320
3198091109940None29.03 Elc SR BESCOM -2022-23Earth work excavation for cable trench of 0.5 to 0.75 Mtr. Width and Depth upto 1 Mtr including trial pits, depositing on bank upto a lead of 50 Mtr,Supplying and Displaying necessary Danger Boards and Lighting, Using sightRails and Sign Boards at every 100 Mtr wherever necessary as directed In soil (hard) ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.CUBIC METER514.1514.150.0FalseNoneNoneFalseNoneFalse25705.00
3198092109940None51.04 v-6 Rod Earthing Rod type of earthing using 40 mm Dia, 3 Mtr long MS rod as ground rod, in earth pit of 300 mm width and 3300 mm depth and using 50x6 mm flat welded to ground rod as terminal & connected to equipment ground terminal using PVC Al wire as specified " ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.No2870.522870.524.0FalseNoneNoneFalseNoneFalse11482.080
3198093109940None51.05 Bentonite clay slurry for earthing in 50 Kg Bag ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Bag486.35486.354.0FalseNoneNoneFalseNoneFalse1945.40
3198094109940None11.3.2 v-6ELECTRICAL FIXTURES Supplying of .feet - PVC Batten with integrated LED tube .W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fighting 1 x4'- 20/22 w ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Each911.9911.953.0FalseNoneNoneFalseNoneFalse48330.70
3198095109940None11.5.2 v-6Supply of round/square recess/surface mounted rolling type LED Down light with . W GU 10 LED Lamp Rib Fabricated from diecast aluminium with white powder coated prewired to mains connector & has swivelling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @50/60Hz & Power factor 0.9 along with CE approved. 2years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 10-12W ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Each1169.621169.6212.0FalseNoneNoneFalseNoneFalse14035.440
3198096109940None11.11.3 v-6Supplying & fixing of retrofit type - LED bulb.W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70%. efficacy 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 7 W, 6500K ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Each196.92196.926.0FalseNoneNoneFalseNoneFalse1181.520
3198097109940None11.11.5 v-6Supplying & fixing of retrofit type - LED bulb.W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70%. efficacy 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 12W, 6500K ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Each355.51355.514.0FalseNoneNoneFalseNoneFalse1422.040
3198098109940None12.46 v-6Supplying & Fixing of 70-150 Watts lamp holder 2 Pin ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Each83.2683.2610.0FalseNoneNoneFalseNoneFalse832.60
3198099109940None11.8.2 v-6Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with .W System Power consumption. LED Efficiency130lm/w, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Streetlight 40W ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.No5318.125318.122.0FalseNoneNoneFalseNoneFalse10636.240
3198100109940None6.1 v-6Supplying exhaust fan of 1440 RPM of 300mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply. ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Each1971.831971.8310.0FalseNoneNoneFalseNoneFalse19718.30
3198101109940None6.3.1 v-6Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system. 48" Sweep (1200mm) Regular model ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Each3943.653943.6524.0FalseNoneNoneFalseNoneFalse94647.60
3198102109940None13.7.1 v-6Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall / ceiling / Rafter / Girders ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Each161.24161.2465.0FalseNoneNoneFalseNoneFalse10480.60
3198103109940None13.1 v-6 Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S' hook with fan regulator to the existing board together with supplying and fixing 5 amps. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring." ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Each225.99225.9924.0FalseNoneNoneFalseNoneFalse5423.760
3198104109940None13.13 v-6Fixing one exhaust fan after making a suitable nitch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 amps, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame. ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Each934.37934.3710.0FalseNoneNoneFalseNoneFalse9343.70
3198105109940None13.4.1 v-6Supplying and fixing telescopic M.S. bracket fabricated by using 0.5m length 4” dia telescopic M. S. pipe, with 2” dia 1.5m long M. S. bracket and are welded with suitable angle, using 6mm thick M. S. sheet, grip bolts & nuts, as required, suitable for 9 to 12 Mtrs. M. S. tubular pole, with necessary two coats of painting, with all other accessories. Single bracket 1.5 Mtr. Length ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Each1930.861930.862.0FalseNoneNoneFalseNoneFalse3861.720
3198106109940None13.5 v-6Fixing halogen/metal halide / SVL / IL / LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires. ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Each214.1214.12.0FalseNoneNoneFalseNoneFalse428.20
3198107109940None5.42.2 v-6L.T.PANEL Fabricating supplying and mounting MS box made out .SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour etc., complete 16SWG ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Sq CM0.570.5760000.0FalseNoneNoneFalseNoneFalse34200.00
3198108109940None5.40.1 v-6Supplying .amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 100Amps 4x30x6mm Aluminum Strips ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.m3257.743257.741.0FalseNoneNoneFalseNoneFalse3257.740
3198109109940None5.41.1 v-6 Supplying and fixing angle iron frame work iabricated out of M.S. angle iron. and M.S. flat . with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 40x40x6mm ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.m403.09403.0910.0FalseNoneNoneFalseNoneFalse4030.90
3198110109940None5.41.1 v-6Supplying and fixing angle iron frame work iabricated out of M.S. angle iron. and M.S. flat . with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 50x100x50x6mm C channel ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.m522.03522.0310.0FalseNoneNoneFalseNoneFalse5220.30
3198111109940None5.15.9 v-6Supplying and fixing Moulded Case Circuit Breaker (MCCB) over theexisting wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection ofOverload and Short circuitwith adjustable thermal magnetic release,Micro processor release shall have Earth Fault as per IS/IEC 60947-2 .(Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility forsegregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulationbetween front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open).Multi-pole breakers shall be designed to break all the polessimultaneously and they shall have a single mechanism" FOUR POLE100Amps 25kA ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Each11216.4211216.422.0FalseNoneNoneFalseNoneFalse22432.840
3198112109940None5.33 v-6Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH,KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Each12310.712310.71.0FalseNoneNoneFalseNoneFalse12310.70
3198113109940None5.38 v-6Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.C ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Each613.22613.223.0FalseNoneNoneFalseNoneFalse1839.660
3198114109940None5.34 v-6Supplying, fixing and wiring 50/5 to 400/5Amps 5VA burden Current Transformer. Class 0.5 accuracy with Tape Wound (48/6.32) ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Each742.73742.733.0FalseNoneNoneFalseNoneFalse2228.190
3198115109940None5.35 v-6Supplying, fixing and wiring Electronic Trivector Meter (ETV) 5 to 32/63 A three phase 4 wire whole current class-1 Accuracy Energy Meter ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Each7539.737539.731.0FalseNoneNoneFalseNoneFalse7539.730
3198116109940None9.3.2 v-6Supplying, erecting, testing & commissioning of ON-LINE UPS system suitable for operation on 230V, 50Hz, A/C supply, with isolation transformer all accessories complete and Excluding batteries and wiring complete. 3 kVA ON LINE UPS ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Each51171.0351171.031.0FalseNoneNoneFalseNoneFalse51171.030
3198117109940None9.5.3 v-6 Supplying, installation, testing & commissioning of 12V DC, AH batteries in poly propylene container for U.P.S. Sealed maintenance free batteries. 26 AH capacity ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Each4772.34772.316.0FalseNoneNoneFalseNoneFalse76356.80
3198118109940None8.1 v-6TELEPHONE AND NETWORKING Supplying and drawing UTP-CAT 6E LAN cable. ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.m50.2250.22330.0FalseNoneNoneFalseNoneFalse16572.60
3198119109940None8.10.1 v-6Supplying & Fixing of I/O Socket with back box Single I/O ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Each647.58647.5811.0FalseNoneNoneFalseNoneFalse7123.380
3198120109940None8.4.1 v-6Supplying & Fixing of switch mounting rack with power manager & Cable manager (85/11.4) 4U with 450mm depth ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Each6465.276465.271.0FalseNoneNoneFalseNoneFalse6465.270
3198121109940None8.9.11 v-616 port 10/100/1000 Switch ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Each8511.18511.11.0FalseNoneNoneFalseNoneFalse8511.10
3198122109940None8.11.1 v-6Supplying & fixing of .mtrs. Cat 6Patch Cable. 2Mtr ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Each296.04296.0411.0FalseNoneNoneFalseNoneFalse3256.440
3198123109940None8.12.3 v-6 Supplying & Fixing of Patch panel for Lan Cabling. 16 Port 10/100 patch panel ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Each4030.884030.881.0FalseNoneNoneFalseNoneFalse4030.880
3198124109940None8.13.2 v-6Supplying and fixing of MDF krone junction box with KRONEModule / Telephone cable termination. 20 Pair ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.m506.17506.171.0FalseNoneNoneFalseNoneFalse506.170
3198125109940None6.7.1 v-6Supplying .TR split Air conditioners suitable for operation on A/C supply single phase 50 Hz 230 V with hermetically sealed compressor with air cooled condenser, motor capacitor and start run capacitors, relay and over load protector internal unit, with one indoor and one outdoor unit The condenser unit will be placed outside the room on the terrace to avoid noise including standard length of suitable size copper tubing covered with insulation tube. (High wall chorded/cordless) suitable capacity 3 core sheathed/ PVC copper cable and a battery operated wireless remote unit 5star 1 Ton capacity ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Each55118.6555118.652.0FalseNoneNoneFalseNoneFalse110237.30
3198126109940None6.12 v-6Installation charges for split type air conditioner with allied works for one indoor and one outdoor unit is to be mounted on suitable Angle Iron support up to 3.0 ton split/cassette type A/C. ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Each4196.084196.082.0FalseNoneNoneFalseNoneFalse8392.160
3198127109940None9.1.1 v-6Supplying, erecting, testing and commissioning of voltage stabilizer suitable for 170 to 270 v in put and load variation from no load to full load, with over load protection, spike suppression, operating at 00 C to 400 C. Range etc., complete. 3 KVA Capacity ---- etc. complete with all lead and lift as per detailed specification and directions of the Engineer incharge of the work.Each5279.795279.792.0FalseNoneNoneFalseNoneFalse10559.580
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17169672380000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17169672380000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17169672380000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of Karnataka public Procurement on or before the last date and time of bid submission.None
17169672380000NoneNoneELIGIBILITYThe bidder is required to ensure browser compatibility of the computer well in advance to the last date and time for receipt of tenders. The departments shall not be responsible for non-accessibility of Karnataka public Procurement portal due to internet connectivity issues and technical glitches at bidders endNone
17169672380000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejectionNone
17169672380000NoneNoneELIGIBILITYBidder shall pay Contract Management Module processing fees of 0.025% of the contact value (Min Rs.500/- & Max Rs.7500/-) soon after contract has been issued to bidderNone
17169672380000NoneNoneELIGIBILITYThe tenderer shall bear all costs associated with the preparation and submission of his tender, and the employer will in no case be responsible and liable for those costsNone
17169672380000NoneNoneELIGIBILITYConditional tenders will not be accepted.None
17169672380000NoneNoneELIGIBILITYAll the formats prescribed in the bid document shall be filled by the tenderer in complete manner.None
17169672380000NoneNoneELIGIBILITYRoyalty on construction materials and other taxes will be deducted as per prevailing Govt., orders as may be modified from time to time.None
17169672380000NoneNoneELIGIBILITYAny discrepancies observed in the documents uploaded by the tenderer the tender shall liable to rejected.None
17169672380000NoneNoneELIGIBILITYEarnest Money Deposit will have to be in any one of the forms as per the instructions in the financial bid document and shall have to be valid for 45 days beyond the validity of the tender.None
17169672380000NoneNoneELIGIBILITYAll formats prescribed in the bid documents shall be filled in complete manner (section 2 & of the bid document)and shall be uploaded properly, signed by tenderer. Necessary certificates shall be uploaded along with the formats wherever required. General documents section can be used for this purposeNone
17169672380000NoneNoneELIGIBILITYTenderers are required to read the Bid Documents carefully before submission of their bidNone
17169672380000NoneNoneELIGIBILITYIf the tenderer quotes bid price below the estimated contract value (Amount put to tender) then the tenderer has to submit the additional security deposit equal to the difference in cost and the additional security deposit should have a validity for the period of execution.None
17169672380000NoneNoneELIGIBILITYIf the numbers of page to be attached in one particular attachment is more, then all the pages can be put into one folder, zipped and then attached or else all the pages can be pasted in one word file and then this word file could be converted to PDF (portable documents format) format and then attached. (Please contract help desk from 9.00 AM to 9.00 PM ( Monday to Saturday) Ph No: 91-8046010000 and 91-8068948777 or send query through Karnataka public procurement portal through query option on or before specified time.None
17169672380000NoneNoneELIGIBILITYThe Contractor shall strictly take all reasonable steps to protect the environment on and off the site and to avoid damage or nuisance to persons or to property of the public or others resulting from pollution, noise or other causes arising as a consequence of his methods of operation.None
17169672380000NoneNoneELIGIBILITYMaterials like, steel (primary), cement, bitumen etc., required for the work shall be procured by the tenderer themselves and should be got tested positive by the quality control authority before use on the work.None
17169672380000NoneNoneELIGIBILITYTenderer should have latest GST Registration and latest clearance certificate in their nameNone
17169672380000NoneNoneELIGIBILITYThe Rates quoted by the tenderer shall be inclusive of GST.None
17169672380000NoneNoneELIGIBILITYSpecial Instructions to tenderers - as per bid document.None
17169672380000NoneNoneELIGIBILITYThe Defects Liability Period is 1 year from the date of completion of the work.None
17169672380001NoneNoneELIGIBILITYTotal value of Civil Engineering Construction works executed in the and payments received in the last five year i.e., 2019-20, 2020-21 2021-22, 2022-2023 & 2023-24None
17169672380000NoneNoneELIGIBILITYThe Tenderers are bound to furnish the original certified documents to the employer within 3 days from the day of opening of technical bid for verification, failing which the bid of tenderer will be considered as technically non responsive.None
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneOwning the following key and critical equipment for this work (xxxx, xxxx, xxxx)NoneNone
NoneNoneNoneNoneTotal value of civl engineering works executed and payments received in the last five years (year-wise)NoneNone
NoneNoneNoneNoneList of works for which tenders already submittedNoneNone
NoneNoneNoneNoneBanker Details for referenceNoneNone
NoneNoneNoneNoneConstruction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneReports on the financial standing of the tenderer, such as profit and loss statements and auditor’s reports for the last five yearsNoneNone
NoneNoneNoneNoneClause ITT 3.2(b)To qualify for award of this contract, each Tenderer in his/its name should have in the last five years i.e.(2019-20 to 2023-24) The tenderer should have been Satisfactorily completed at least one Satisfactorily completed at least one Similar work of value not less than Rs.52.50 Lakhs as prime contractor. Note : The Work done certificate should be issued by the Officer not less than the rank of Executive Engineer of State or Central Government/ Semi Government/Government undertaking/ autonomous bodies of Government will be considered for the clause 3.2 (b).Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneClause 3.2(c) To qualify for award of this contract, each Tenderer in his/its name should have in the last five years i.e.(2019-20 to 2023-24). Executed in any one financial year, the following minimum quantities of work Sl. No Description of key items of works Quantity 1)Earthwork Excavation -18.00 Cum,2)RCC and PCC- 80.00 Cum 3)Steel Reinforcement for RCC work- 10 Tonnes 4)Cement concrete Block Masonry/Solid Block Masonry/Laterite/Load bearing wall -300.00 Sqm 5)Flooring / Dadooing (Vitrified/ Granite/ Ceramic/ Cement concrete/cladding/ dadooing)- 390.00 Sqm,6)Plastering -2600.00 Sqm,7)Painting -2500.00 Sqm (8)MS grill 385.00 Kg, 9)WPC -30.00sqm. Note-The Work done certificate should be issued by the Officer not less than the rank of Executive Engineer of State or Central Government/ Semi Government/Government undertaking/ autonomous bodies of Government will be considered for the clause 3.2 (c).Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneClause 3.2(d) The tenderer or his identified sub contractor should possess required valid electrical license for executing building electrification works issued by KPWD/ Government electrical Inspectorate and should have executed similar Building electrical works totaling Rs.7.00 Lakhs in any one year.Note-The Work done certificate should be issued by the Officer not less than the rank of Executive Engineer of State or Central Government/ Semi Government/Government undertaking/ autonomous bodies of Government will be considered for the clause 3.2 (d). The letter of willingness of the sub contractor to be engaged for electrical works should be obtained and uploaded in the e-portal.Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneClause 3.2(e)The Tenderer or his identified sub-contractor should possess valid license for executing water supply/sanitary engineering works issued by BWSSB/ KUWS&DB and should have executed similar building water supply/sanitary engineering works totaling Rs.1.50 Lakhs in any one year. Note-The Work done certificate should be issued by the Officer not less than the rank of Executive Engineer of State or Central Government/ Semi Government/Government undertaking/ autonomous bodies of Government will be considered for the clause 3.2 (e). The letter of willingness of the sub contractor to be engaged for water Supply works should be obtained and uploaded in the e-portal.Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneClause 3.6 Tenderers who meet the above specified minimum qualifying criteria, will only be qualified, if their available tender capacity is more than the total tender value. The available tender capacity will be calculated for prime contractor are as under Assessed available tender capacity AxNx1.5- B Where A maximum value of civil engineering works executed in any one year during the last five years 2019-20 to 2023-24 updated to 2024-25 price level taking into account the completed as well as works in progress. N Number of years prescribed for completion of the works for which tenders are invited. B Value, at 2024-25 price level, of existing commitments and ongoing works to be completed during the next 06 months. Note:The statements showing the value of existing commitments and on-going works as well as the stipulated period of completion remaining for each of the works listed should be countersigned by the Employer in charge, not below the rank of an Executive Engineer or equivalent. certificate issued by the officer not less than the rank of Executive Engineer Ongoing commitments and Bids submitted for the worksCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- certificate issued by the officer not less than the rank of Executive Engineer Ongoing commitments and Bids submitted for the works
NoneNoneNoneNoneList of Minimum Key Personnel to be deployed by the contractor at site for Contract work Sl NoPosition Qualification and Requirement No Of Persons 1)Site Engineer BE Civil with minimum experience of 7 years in the Construction of buildings Or Diploma in Civil Engineering with minimum experience of 10 years in the Construction of buildings and should have been working in permanent role of the organization for at least two years -1 One No 2)Electrical Engineer BE Electrical with minimum experience of 5 years in the Construction of buildings Or Diploma in Electrical Engineering with minimum experience of 10 years in the Construction of buildings and should have been working inpermanent role of the organization for at least two years-1 One No.Degree certificate and Experience Certificate to be furnished.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Degree certificate and Experience Certificate to be furnished.
NoneNoneNoneNoneKPWD Class-III and above Registration CertificateCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- KPWD Class-III and above Registration Certificate issued by Competant Authority
NoneNoneNoneNoneClause ITT 3.2(a): To qualify for award of this contract, each Tenderer in his/its name should have in the last five years i.e.(2019-20 to 2023-24) The tenderer should have been achieved in at least two financial years a minimum annual financial turnover (in all classes of civil Engineering construction works only) of Rs.210.00 Lakhs. Note : a) For Clause 3.2 (a) the certificate duly certified by the charted accountant is to be submitted.Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNoneClause 3.3(b)Liquid assets and /or availability of credit facilities of not less than Rs.32.00 Lakhs (Credit lines / letter of credit/ certificates from banks for meeting the fund requirement etc.(As per the prescribed format in clause 1.10 of SECTION 3, QUALIFICATION INFORMATION of this document.) as prime Contractor.Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneLine of Credit
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Annual Turnover Certificate issued by Chartered AccountantTrueTechnical Bid
KPWD Registration Certificate issued by Competant AuthorityTrueTechnical Bid
Work done certificate issued by not below the rank of Executive Engineer.TrueTechnical Bid
Tenderer should have latest GST Registration PAN Card and latest 3 GST clearance certificate in their nameFalseTechnical Bid
Tenderer should have ESI & PF Certificates his/firm name and PF paid receipt of last month.TrueTechnical Bid
tenderWorkLocationList
tenderAddress
createdTs1717066170000
version0
createdDateNone
modifiedDateNone
blockNumberOffice of the Chief Engineer, Engineering Wing, Arogya Soudha, 3rd floor, Leprosy Hospital premises, 1st cross, Magadi Road
streetNone
cityBengaluru
stateKarnataka
pin560023
tenderRecallDTONone