createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1716967564059
version18
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee2760.00
emd200000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose13-06-2024 16:00:00
tenderQueryClose04-06-2024 14:00:00
technicalBidOpen14-06-2024 16:30:00
publishedDate30-05-2024 16:17:41
publishedByPostEWHFWD_CE_CEOFF_BNG
publishedByUserKPE16838 - BALEKATTE KUMARASWAMY PAVITHRA
bidValidityPeriod90
noOfCalls2
preBidMeetingDate05-06-2024 11:14:30
preBidMeetingYnTrue
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnTrue
percentageRateTypeTextNone
contactPersonAssistant Engineer
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumber08029557023
mobileNumber9449843375
tenderSupplierListNone
tenderSchedule
createdTs1716967564062
version33
createdDateNone
modifiedDateNone
tenderNumberEWHFWD/2023-24/BD/WORK_INDENT251/CALL-2
titleConstruction of District Integrated Public Health Laboratory in the premises of GIMS at Gadag
descriptionConstruction of District Integrated Public Health Laboratory in the premises of GIMS at Gadag
categoryWORKS
categoryTextWorks
ecv11006142.03
deptNameEngineering Wing of Health and Family Welfare Department
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnFalse
location3521
locationNameEWHFWD Chief Engineer Office Bengaluru
provisionalAmount11100000.0
groupOverheadTotal0.0
fileNumberaeeengdwd-1112023-24
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17169675640000NoneNoneBuildingsDistrict Integrated Public Health Laboratory at GIMS, Gadag- Civil Works9317385.49
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3198156109943NoneItem 2.5AClearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness.By Mechanical Means using Dozer.A In area of light jungle Per 100 sqm ---- etc., complete with all leadSqm477.66477.663.85FalseNoneNoneFalseNoneFalse1838.9910
3198157109943NoneItem 1.12Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depth ---- etc., complete with all leadCum115.46115.46115.5FalseNoneNoneFalseNoneFalse13335.630
3198158109943NoneItem 1.14.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m ---- etc., complete with all leadCum123.97123.97122.84FalseNoneNoneFalseNoneFalse15228.47480
3198159109943NoneItem 1.15.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In ordinary/soft rock without blasting upto 1.5 m depth ---- etc., complete with all leadCum441.19441.1913.15FalseNoneNoneFalseNoneFalse5801.64850
3198160109943NoneItem 1.1ALoading and Unloading of Stone Boulder/Stone aggregates/ Sand/Kankar/Moorum. (Disposal of 10Km) ---- etc., complete with all leadCum143.41143.4163.158FalseNoneNoneFalseNoneFalse9057.488780
3198161109943NoneItem 4.1Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications. ---- etc., complete with all leadSqm143.41143.41305.5FalseNoneNoneFalseNoneFalse43811.7550
3198162109943NoneItem 1.9Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. ---- etc., complete with all leadCum323.29323.29123.34FalseNoneNoneFalseNoneFalse39874.58860
3198163109943NoneItem 1.8Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. ---- etc., complete with all leadCum576.09576.09374.11FalseNoneNoneFalseNoneFalse215521.02990
3198164109943NoneItem 2.1.3Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates ---- etc., complete with all leadCum7279.037279.0347.18FalseNoneNoneFalseNoneFalse343424.63540
3198165109943NoneItem 2.2.2.1Footing Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Footings ---- etc., complete with all leadCum8316.848316.8426.51FalseNoneNoneFalseNoneFalse220479.42840
3198166109943NoneItem 2.2.2.1Pedestal Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Pedestals ---- etc., complete with all leadCum8470.858470.853.375FalseNoneNoneFalseNoneFalse28589.118750
3198167109943NoneItem 2.5.2Columns Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates coloums ---- etc., complete with all leadCum14138.8614138.8616.49FalseNoneNoneFalseNoneFalse233149.80140
3198168109943NoneItem 2.5.2Plinth Beams Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates plinth beams ---- etc., complete with all leadCum12475.4712475.4723.6FalseNoneNoneFalseNoneFalse294421.0920
3198169109943NoneItem 2.5.2Roof Beam Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Roof beams ---- etc., complete with all leadCum13307.1613307.1618.192FalseNoneNoneFalseNoneFalse242083.854720
3198170109943NoneItem 2.5.2Slab Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Roof beams ---- etc., complete with all leadCum12475.4712475.4750.7975FalseNoneNoneFalseNoneFalse633722.6873250
3198171109943NoneItem 2.5.2Lintel Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Lintel ---- etc., complete with all leadCum13307.1613307.161.88FalseNoneNoneFalseNoneFalse25017.46080
3198172109943NoneItem 2.1.4Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates ---- etc., complete with all leadCum8311.758311.755.04FalseNoneNoneFalseNoneFalse41891.220
3198173109943NoneItem 17.4Providing and inserting nipples with approved fixing compound after drilling holes for grouting as per Technical Specifications including subsequent cutting/removal and sealing of the hole as necessary of nipples after completion of grouting with Cement/Epoxy ---- etc., complete with all leadNos247.94247.9420.0FalseNoneNoneFalseNoneFalse4958.80
3198174109943NoneItem 8.83Providing Lath plaster with cement mortar 1:3 5cm thick with 6mm dia mild steel bars at 20cms. C to c both horizontally and vertically fixing chicken mesh for drop chejjas, facia, backing to cup board including cost of all materials, labour, providing and removing form work HOM of machineries, curing, complete as per specification. ---- etc., complete with all leadSqm1504.661504.664.72FalseNoneNoneFalseNoneFalse7101.99520
3198175109943NoneItem 11.32Providing Thermo-Mechanically Treated bars of grade Fe-550D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) ---- etc., complete with all leadt108726.03108726.0319.0FalseNoneNoneFalseNoneFalse2065794.570
3198176109943NoneApproved RateKSRB 4-2.12 : Extra for providing throating or drip moulding to RCC chejjas with plastering ( labour charges only ) as per specifications. Specification No . KBS ---- etc., complete with all leadm38.9438.9456.49FalseNoneNoneFalseNoneFalse2199.72060
3198177109943NoneApproved RateProviding throating elevation Patti on uniform size 10 cm wide and 12 mm thick for portico, chejjas & parapet wall elevation etc, including cost of materials , labour floor fixing, HOM of equipments and machineries all leads and lift loading and unloading, transportation , all other incidental charges at all floor levels etc, complete all as per specifications and as directed by the Engineer in charge. ---- etc., complete with all leadm86.1486.1456.49FalseNoneNoneFalseNoneFalse4866.04860
3198178109943NoneItem 5.4Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) ---- etc., complete with all leadCum7765.197765.195.86FalseNoneNoneFalseNoneFalse45504.01340
3198179109943NoneItem 6.32Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- etc., complete with all leadSqm1592.171592.17492.27FalseNoneNoneFalseNoneFalse783777.52590
3198180109943NoneItem 6.34Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- etc., complete with all leadSqm1341.81341.843.19FalseNoneNoneFalseNoneFalse57952.3420
3198181109943NoneItem 12.13.1Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. ---- etc., complete with all leadCum120099.75120099.751.58FalseNoneNoneFalseNoneFalse189757.6050
3198182109943NoneItem 12.5Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. ---- etc., complete with all leadNos1234.841234.8416.0FalseNoneNoneFalseNoneFalse19757.440
3198183109943NoneItem Approved RateProviding and fixing 100/125 mm mortice latch, lock with 6 levers and a pair of lever handles, SS Handles 100/125mm, Tower Bolts, Door Catcher, Hinges 12*85*5.5mm of approved quality with necessary screws etc. complete. ---- etc., complete with all leadNos5310.05310.016.0FalseNoneNoneFalseNoneFalse84960.00
3198184109943NoneItem 10.6.3Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm ---- etc., complete with all leadNos72.9272.9296.0FalseNoneNoneFalseNoneFalse7000.320
3198185109943NoneItem Approved RateProviding & Fixing of corner beads of wooden door frame to wall including cost of materials, labour charges, complete as per specifications. ---- etc., complete with all leadm14.9914.99116.79FalseNoneNoneFalseNoneFalse1750.68210
3198186109943NoneItem 12.57.6Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 35 mm thick both side commercial ---- etc., complete with all leadSqm4037.554037.5547.99FalseNoneNoneFalseNoneFalse193762.02450
3198187109943NoneItem 12.89Providing & fixing of 2.5-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc., complete with all leadSqm7962.087962.0840.5FalseNoneNoneFalseNoneFalse322464.240
3198188109943NoneItem 12.85Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc., complete with all leadSqm6950.876950.873.78FalseNoneNoneFalseNoneFalse26274.28860
3198189109943NoneItem 11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding ---- etc., complete with all leadKg204.18204.18929.9FalseNoneNoneFalseNoneFalse189866.9820
3198190109943NoneItem 12.93Providing & fixing Factory made single extruded Wood Polymer composite (WPC) Solid Door /Window, clerestory windows and frames /chowkat of frame size 65 * 100mm.The cost includes cost of materials and transportation, labour and fixing charges. ---- etc., complete with all leadm853.21853.2120.4FalseNoneNoneFalseNoneFalse17405.4840
3198191109943NoneItem 12.96Providing and fixing factory made 100% carpenter friendly ready to use single solid plain WPC (WoodPolymer Composite) flush shutter of 30mm thickness which is anti termite & having high water absorption property. The cost includes cost of materials and transportation, labour and fixing charges. ---- etc., complete with all leadSqm4235.664235.667.56FalseNoneNoneFalseNoneFalse32021.58960
3198192109943NoneItem 12.59Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. ---- etc., complete with all leadNos1353.951353.9516.0FalseNoneNoneFalseNoneFalse21663.20
3198193109943NoneItem 11.25.2Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., complete with all leadKgs165.29165.29241.92FalseNoneNoneFalseNoneFalse39986.95680
3198194109943NoneItem 8.4.2Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge... ( Inside) ---- etc., complete with all leadSqm379.2379.2761.92FalseNoneNoneFalseNoneFalse288920.0640
3198195109943NoneItem 8.1Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm256.44256.44529.04FalseNoneNoneFalseNoneFalse135667.01760
3198196109943NoneItem 8.51Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. ---- etc., complete with all leadSqm121.54121.541290.96FalseNoneNoneFalseNoneFalse156903.27840
3198197109943NoneItem 8.5.2Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.. ( Outside) ---- etc., complete with all leadSqm424.17424.17312.27FalseNoneNoneFalseNoneFalse132455.56590
3198198109943NoneItem Approved RateKSRB 15.8.3 Providing and fixing plaster mesh 200mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120gms per Sqm width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment ) ---- etc., complete with all leadm42.4842.48662.0FalseNoneNoneFalseNoneFalse28121.760
3198199109943NoneItem Approved RateBore Packing : Filling the bore wherever necessary with polymer modified concrete and brushing one coat of acrylic copolymer cross linked formulaion on the bore. Including all labour charges tools and equipments, all complete as per the manufacturer. ---- etc., complete with all leadSqm283.2283.210.0FalseNoneNoneFalseNoneFalse2832.00
3198200109943NoneItem 8.79Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove. ---- etc., complete with all leadm63.263.2292.0FalseNoneNoneFalseNoneFalse18454.40
3198201109943NoneItem 9.17.2Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete..).Size of Tile 600x600 mm ---- etc., complete with all leadSqm1428.091428.09265.07FalseNoneNoneFalseNoneFalse378543.81630
3198202109943NoneItem 8.2.1Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm358.54358.54133.875FalseNoneNoneFalseNoneFalse47999.54250
3198203109943NoneItem 9.24Providing and laying Polished Granite flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.** Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent. ---- etc., complete with all leadSqm3466.323466.3237.27FalseNoneNoneFalseNoneFalse129189.74640
3198204109943NoneItem 9.29Providing and laying flooring and steps fine dressed granite stone slabs 40 mm thick on cement mortar bed 1:6, 25 mm thick, and pointed with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. ---- etc., complete with all leadSqm5233.515233.5131.44FalseNoneNoneFalseNoneFalse164541.55440
3198205109943NoneItem 15.7Providing and supplying crystalline integral concrete waterproofing admixture that waterproofs concrete by forming crystals deep in the pores, capillaries and microcracks of the concrete, self-seal waterproofing compound to bridge shrinkage cracks upto 0.5mm in width & resist hydro-static pressure upto 16bar for both positive & negative pressure confirming to DIN 1048 part 5 for 56% reduction in depth of penetration against control, resistance to chloride penetration confirming to ASTM C 1202 with 64% improvement against control & protecting steel re-inforcement against corrosion mixed @ 1% by weight of cementitious content in concrete. ie., integral crystaline waterproofing admix @ 0.5 kg/bag of cement. (For calculation purpose 320 kg of Cement for M-20 grade of Concrete is considered in the analysis) ---- etc., complete with all leadSqm747.47747.4725.62FalseNoneNoneFalseNoneFalse19150.18140
3198206109943NoneItem 9.11Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 including pointing the joints with white cement and matching pigment etc., complete. ---- etc., complete with all leadSqm1307.771307.7725.62FalseNoneNoneFalseNoneFalse33505.06740
3198207109943NoneItem 9.39Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. ---- etc., complete with all leadSqm1761.111761.1196.6FalseNoneNoneFalseNoneFalse170123.2260
3198208109943NoneItem 8.39Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm154.35154.35529.04FalseNoneNoneFalseNoneFalse81657.3240
3198209109943NoneItem 8.32Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm189.6189.6312.27FalseNoneNoneFalseNoneFalse59206.3920
3198210109943NoneItem 8.4Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm139.77139.7744.28FalseNoneNoneFalseNoneFalse6189.01560
3198211109943NoneItem 8.34.1Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm64.4164.41115.19FalseNoneNoneFalseNoneFalse7419.38790
3198212109943NoneItem 8.47Polishing on wood work with ready mixed wax polish of approved brand and manufacture : New work to give an even surface including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm164.07164.07115.19FalseNoneNoneFalseNoneFalse18899.22330
3198213109943NoneItem 12.92Providing& fixing of Openable door made out of multi chambered UPVC(Matching to RAL9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPV(Thermo Plastic Vulcanized) and lead free with gaskets grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the openable frame. The frame having overall size of 60mm x 55mm with GI reinforcement of 1mm thickness and openable sash with overall size of 60mm x 102mm and GI reinforcement of 2mm thickness. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 34 mm. Windows shall be provided with 6mm plain float glass, Standard hardware with 2D/3D hinge Multi point locking system with Handle. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 900mm x 2400mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc., complete with all leadSqm7590.177590.178.4FalseNoneNoneFalseNoneFalse63757.4280
3198214109943NoneItem 12.91Providing& fixing of Openable window made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPV(Thermo Plastic Vulcanized) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the openable frame. The frame having overall size of 60mm x 55mm with GI reinforcement of 1mm thickness and openable sash with overall size of 60mm x 75mm and GI reinforcement of 1.5mm thickness. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 34 mm. Windows shall be provided with 5mm plain float glass, Standard hardware with friction hinge & Multi point locking system with Handle. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 900mm x 1819mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc., complete with all leadSqm7367.757367.7529.79FalseNoneNoneFalseNoneFalse219485.27250
3198215109943NoneItem Approved RateRoof Water Proofing. Surface Preparation: remove all surface laitance and contamination free from loose aggregate or other sharp protrusions with fairly smooth finish by wire brush and grinding method and surface shall be DRY for application of single component pitch modified polyurethane cures by reaction with atmospheric moisture to given a tough elastomeric waterproof membrane. System : Provide and applying 1.2 mm thick roller applied single component bitumen modified polyurathene coating NITPROOF 600 or equivalent, having elongation capacity of 450 % as per ASTM D412, having Tensile strength 1.5 n/mm2 as per ASTM D 412, Tear resistance of 15 N as per ASTM D 624 and having shore A Hardness 50 as per ASTM D 2240. Waterproofing treatment to be provided after proper surface preparation as per Manufacture Specification. Protection of waterproofing system with minimum 50 mm thick screed and providing construction joints and sealing the same with PU sealant. ---- etc., complete with all leadSqm964.06964.06328.89FalseNoneNoneFalseNoneFalse317069.69340
3198216109943NoneItem M010GSupplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: PVC pipes 110mm dia., 6 kg/sqcm & class 3 ---- etc., complete with all leadm504.52504.5224.0FalseNoneNoneFalseNoneFalse12108.480
3198217109943NoneApproved RateProviding and fixing storage unit of 0. 75m depth made out of 19mm thick commercial ply vertical support finished in approved 1.00mm laminate with 12mm thick ply packing internally finished with enamel paint of approved colour and shade shelves shall be formed out of 19mm ply finished with enamel paint of approved shade and colour and 19mm thick shutters formed out of 19mm thick ply finished with 1.00mm thick laminate of approved shade and colour etc., complete the rate includes cost of all materials, labour charges, complete as per specification. ---- etc., complete with all leadSqm17110.017110.016.4FalseNoneNoneFalseNoneFalse280604.00
3198218109943NoneItem 9.21.2Providing and laying Vitrified tiles in floor with different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).Size of Tile 600x600 mm ---- etc., complete with all leadSqm1504.661504.6612.3FalseNoneNoneFalseNoneFalse18507.3180
17169675640000NoneNoneBuildingsDistrict Integrated Public Health Laboratory at GIMS, Gadag- Electrcal Works1252894.59
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3198219109944NoneItem 2.2.1Supplying and wiring adopting loop system in existing PVC Conduit orcasing capping casing capping using 2x1.5Sqmm Phase and Neutral and 1x1.0 sqmm Earth wire FRLS multi strand PVC insulated copper wire confirming to IS694: and latest amendments without control switch shall be fixed on the existing plastic sheetor gang box, the other end of the wires shall be terminated with sufficient loose length in a woodorPVC round block. complete for each outlet.Short point up to 3Mtr from tapping point to out let via switch ---- etc., complete with all leadEach326.94326.9425.0FalseNoneNoneFalseNoneFalse8173.50
3198220109944NoneItem 2.2.2Supplying and wiring adopting loop system in existing PVC Conduit orcasing capping casing capping using 2x1.5Sqmm Phase and Neutral and 1x1.0 sqmm Earth wire FRLS multi strand PVC insulated copper wire confirming to IS694: and latest amendments without control switch shall be fixed on the existing plastic sheetor gang box, the other end of the wires shall be terminated with sufficient loose length in a wood orPVC round block. complete for each outlet.Medium point above 3Mtr up to 6Mtr from tapping point to out let via switch ---- etc., complete with all leadEach460.63460.6334.0FalseNoneNoneFalseNoneFalse15661.420
3198221109944NoneItem 2.2.3Supplying and wiring adopting loop system in existing PVC Conduit orcasing capping casing capping using 2x1.5Sqmm Phase and Neutral and 1x1.0 sqmm Earth wire FRLS multi strand PVC insulated copper wire confirming to IS694: and latest amendments without control switch shall be fixed on the existing plastic sheetor gang box, the other end of the wires shall be terminated with sufficient loose length in a woodorPVC round block. complete for each outlet.Long point above 6Mtr up to 10Mtr from tapping point to out let via switch ---- etc., complete with all leadEach674.54674.5440.0FalseNoneNoneFalseNoneFalse26981.60
3198222109944NoneItem 2.2.4Supplying and wiring adopting loop system in existing PVC Conduit orcasing capping casing capping using 2x1.5Sqmm Phase and Neutral and 1x1.0 sqmm Earth wire FRLS multi strand PVC insulated copper wire confirming to IS694: and latest amendments without control switch shall be fixed on the existing plastic sheetor gang box, the other end of the wires shall be terminated with sufficient loose length in a woodorPVC round block. complete for each outlet.Two outlet in a row, above 3Mtr up to 6Mtr from tapping point to out let via switches ---- etc., complete with all leadEach822.82822.826.0FalseNoneNoneFalseNoneFalse4936.920
3198223109944NoneItem 3.4.1Supplying and flush mounting powder coated or galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in BrickorStoneorC.C wal 13Way ---- etc., complete with all leadEach193.24193.2420.0FalseNoneNoneFalseNoneFalse3864.80
3198224109944NoneItem 3.4.2Supplying and flush mounting powder coated or galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in BrickorStoneorC.C wal 45Way ---- etc., complete with all leadEach215.12215.128.0FalseNoneNoneFalseNoneFalse1720.960
3198225109944NoneItem 3.4.3Supplying and flush mounting powder coated or galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in BrickorStoneorC.C wal 6Way ---- etc., complete with all leadEach267.38267.384.0FalseNoneNoneFalseNoneFalse1069.520
3198226109944NoneItem 3.4.4Supplying and flush mounting powder coated or galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in BrickorStoneorC.C wal 8 Way ---- etc., complete with all leadEach317.22317.2210.0FalseNoneNoneFalseNoneFalse3172.20
3198227109944NoneItem 3.4.5Supplying and flush mounting powder coated or galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in BrickorStoneorC.C wal 1012Way ---- etc., complete with all leadEach387.71387.7135.0FalseNoneNoneFalseNoneFalse13569.850
3198228109944NoneItem 3.5.1Supplying and flush mounting powder coated or galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in BrickorStoneorC.C wal1 to 3 Module ---- etc., complete with all leadEach195.67195.6720.0FalseNoneNoneFalseNoneFalse3913.40
3198229109944NoneItem 3.5.2Supplying and flush mounting powder coated or galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in BrickorStoneorC.C wal4 Module ---- etc., complete with all leadEach212.69212.698.0FalseNoneNoneFalseNoneFalse1701.520
3198230109944NoneItem 3.5.3Supplying and flush mounting powder coated or galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in BrickorStoneorC.C wal6 Module ---- etc., complete with all leadEach284.4284.44.0FalseNoneNoneFalseNoneFalse1137.60
3198231109944NoneItem 3.5.4Supplying and flush mounting powder coated or galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in BrickorStoneorC.C wal 8 Module ---- etc., complete with all leadEach345.17345.1710.0FalseNoneNoneFalseNoneFalse3451.70
3198232109944NoneItem 3.5.5Supplying and flush mounting powder coated or galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in BrickorStoneorC.C wal1012 Module ---- etc., complete with all leadEach418.09418.0935.0FalseNoneNoneFalseNoneFalse14633.150
3198233109944NoneItem 3.6.1Supplying and fixing of modular switch and connected accessories on existing modular switch plate as per IS 3854 and IS 1293.6Amps one way Switch ---- etc., complete with all leadEach123.97123.97184.0FalseNoneNoneFalseNoneFalse22810.480
3198234109944NoneItem 3.6.3Supplying and fixing of modular switch and connected accessories on existing modular switch plate as per IS 3854 and IS 1293.6Amps 3way socket ---- etc., complete with all leadEach207.83207.8379.0FalseNoneNoneFalseNoneFalse16418.570
3198235109944NoneItem 3.6.4Supplying and fixing of modular switch and connected accessories on existing modular switch plate as per IS 3854 and IS 1293.Stepped Fan Regulator. ---- etc., complete with all leadEach433.89433.8924.0FalseNoneNoneFalseNoneFalse10413.360
3198236109944NoneItem 3.6.8Supplying and fixing of modular switch and connected accessories on existing modular switch plate as per IS 3854 and IS 1293.16Amps one way switch ---- etc., complete with all leadEach218.77218.775.0FalseNoneNoneFalseNoneFalse1093.850
3198237109944NoneItem 3.6.10Supplying and fixing of modular switch and connected accessories on existing modular switch plate as per IS 3854 and IS 1293.32Amps DP switch ---- etc., complete with all leadEach396.22396.2213.0FalseNoneNoneFalseNoneFalse5150.860
3198238109944NoneItem 3.6.11Supplying and fixing of modular switch and connected accessories on existing modular switch plate as per IS 3854 and IS 1293.6or16Amps universal socket ---- etc., complete with all leadEach286.83286.8318.0FalseNoneNoneFalseNoneFalse5162.940
3198239109944NoneItem 1.12Supplyin and Fixing Metal Fan Box with Round Hook. ---- etc., complete with all leadNos142.2142.224.0FalseNoneNoneFalseNoneFalse3412.80
3198240109944NoneItem 1.2.1Concealed Conduit System Supplying heavy gauge PVC conduit pipe dia mm thick confirming to IS 2509 with suitable size bends, metalorPVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary2or219or20mm dia 2mm thick ---- etc., complete with all leadm80.2180.21800.0FalseNoneNoneFalseNoneFalse64168.00
3198241109944NoneItem 1.2.2Concealed Conduit System Supplying heavy gauge PVC conduit pipe dia mm thick confirming to IS 2509 with suitable size bends, metalorPVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary2or225mm dia 2mm thick ---- etc., complete with all leadm94.894.8500.0FalseNoneNoneFalseNoneFalse47400.00
3198242109944NoneItem 1.2.3Supplying heavy gauge PVC conduit pipe dia mm thick confirming to IS 2509 with suitable size bends, metalorPVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary2or232mm dia 2.5mm thick ---- etc., complete with all leadm125.18125.18100.0FalseNoneNoneFalseNoneFalse12518.00
3198243109944NoneItem 1.3.1Supplying heavy gauge PVC conduit pipe dia mm thick confirming to IS 2509 with suitable size bends, metalorPVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary.19or20mm dia 2mm thick ---- etc., complete with all leadm82.6482.64400.0FalseNoneNoneFalseNoneFalse33056.00
3198244109944NoneItem 1.3.2Supplying heavy gauge PVC conduit pipe dia mm thick confirming to IS 2509 with suitable size bends, metalorPVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary.25mm dia 2mm thick ---- etc., complete with all leadm96.0196.01250.0FalseNoneNoneFalseNoneFalse24002.50
3198245109944NoneItem 1.3.3Supplying heavy gauge PVC conduit pipe dia mm thick confirming to IS 2509 with suitable size bends, metalorPVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary.32mm dia 2.5mm thick ---- etc., complete with all leadm120.32120.3250.0FalseNoneNoneFalseNoneFalse6016.00
3198246109944NoneItem 2.3.2Wiring for lightingorpower circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:confirming to latest amendments1.5 sqmm ---- etc., complete with all leadm31.631.6400.0FalseNoneNoneFalseNoneFalse12640.00
3198247109944NoneItem 2.3.3Wiring for lightingorpower circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:confirming to latest amendments2.5 sqmm ---- etc., complete with all leadm51.0451.04800.0FalseNoneNoneFalseNoneFalse40832.00
3198248109944NoneItem 2.3.4Wiring for lightingorpower circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:confirming to latest amendments4 sqmm ---- etc., complete with all leadm76.5776.57500.0FalseNoneNoneFalseNoneFalse38285.00
3198249109944NoneItem 2.3.5Wiring for lightingorpower circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:confirming to latestamendments6 sqmm ---- etc., complete with all leadm111.81111.81300.0FalseNoneNoneFalseNoneFalse33543.00
3198250109944NoneItem 5.18.4supplying and fixing regular MCB distribution boards on wallor wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. I Single Door Made out of 14 SWG MS enclosure12 Way SP and N ---- etc., complete with all leadEach2264.292264.291.0FalseNoneNoneFalseNoneFalse2264.290
3198251109944NoneItem 5.18.9supplying and fixing regular MCB distribution boards on wallor wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. I Single Door Made out of 14 SWG MS enclosure4 Way TPN DB ---- etc., complete with all leadEach4907.784907.781.0FalseNoneNoneFalseNoneFalse4907.780
3198252109944NoneItem 5.18.12supplying and fixing regular MCB distribution boards on wallor wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. I Single Door Made out of 14 SWG MS enclosure6 Way TP and N ---- etc., complete with all leadEach6004.076004.071.0FalseNoneNoneFalseNoneFalse6004.070
3198253109944NoneItem 5.17.1Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ONorOFF, energy cross3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898632Amps SP ---- etc., complete with all leadEach504.39504.3940.0FalseNoneNoneFalseNoneFalse20175.60
3198254109944NoneItem 5.17.8Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ONorOFF, energy cross3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 6089840 A TPN ---- etc., complete with all leadEach3699.673699.671.0FalseNoneNoneFalseNoneFalse3699.670
3198255109944NoneItem 5.17.9Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ONorOFF, energy cross3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 608985063Amps TPN ---- etc., complete with all leadEach3753.153753.151.0FalseNoneNoneFalseNoneFalse3753.150
3198256109944NoneItem 5.17.4Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ONorOFF, energy cross3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898632Amps DP ---- etc., complete with all leadEach898.18898.181.0FalseNoneNoneFalseNoneFalse898.180
3198257109944NoneItem 5.20.3Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker ELMCB 240or450V up to 300mA sensitivity on existing woodorpanel board 3240 Amps 4 pole ---- etc., complete with all leadEach5541.05541.02.0FalseNoneNoneFalseNoneFalse11082.00
3198258109944NoneItem BSR32.091.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS1554 Part 1 or IS7098 Part1, Armouring strip thickness and resistivity as per IS3975 3.5 core 35 sqmm ---- etc., complete with all leadKm214930.12214930.120.1FalseNoneNoneFalseNoneFalse21493.0120
3198259109944NoneItem BSR 31.06Laying of cable in Existing TrenchorGI pipeorStone WareorRCC Hume pipe using WoodenorAluminum Rollers as directed by the departmental staff 35 sqmm to 95 sqmm ---- etc., complete with all leadKm28740.5628740.560.1FalseNoneNoneFalseNoneFalse2874.0560
3198260109944NoneItem SR 19-20 6.11.3Supplying and fiixing of heavy duty cable glands suitable for UG cable of 1.1 KV class metal only 32mm dia ---- etc., complete with all leadEach148.27148.278.0FalseNoneNoneFalseNoneFalse1186.160
3198261109944NoneItem BSR 49.05Supplying and fixing of class A medium duty GI pipe of wall thick ness not less than 3.25mm on poleorwallordrain crossing with necessary clamping arrangements for UG cable of 1.1 KV class. 50mm ---- etc., complete with all leadm465.49465.4910.0FalseNoneNoneFalseNoneFalse4654.90
3198262109944NoneItem SR 19-20 6.17.8Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 35 sqmm Long Barrel ---- etc., complete with all leadEach38.8938.898.0FalseNoneNoneFalseNoneFalse311.120
3198263109944NoneItem BSR 29.03Earth work excavation for cable trench of 0.5 to 0.75 Mtr. Width and Depth upto 1 Mtr including trial pits, depositing on bank upto a lead of 50 Mtr,Supplying and Displaying necessary Danger Boards and Lighting, Using sightRails and Sign Boards at every 100 Mtr wherever necessary as directed In soil hard ---- etc., complete with all leadCum472.79472.7950.0FalseNoneNoneFalseNoneFalse23639.50
3198264109944NoneItem SR 1920 6.2Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc using 40mm dia 2.9mm thick 2.5 mtr long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode. The funnel should be enclosed in a CC chamber of 400x400x400mm with a cast iron cover. The earth electrode shall have staggered holes of 12mm dia and the electrode should be covered 150mm alround with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts. ---- etc., complete with all leadNos5043.915043.912.0FalseNoneNoneFalseNoneFalse10087.820
3198265109944NoneItem SR 1920 6.3.1upplying and running of GIorCopper strips for grounding connections, using necessary fixing materials as required. 25x3mm GI strip ---- etc., complete with all leadm99.6699.6620.0FalseNoneNoneFalseNoneFalse1993.20
3198266109944NoneItem 11.3.2Supplying of ......feet PVC Batten with integrated LED tube W with high quality diffuser with Life of 25000 burning hours and 70percent lumen maintenance with CRI 80. Power Input: 220240V at 50or60Hz and Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fighting 1 x4' 20or22 w ---- etc., complete with all leadEach838.62838.6253.0FalseNoneNoneFalseNoneFalse44446.860
3198267109944NoneItem 11.5.2Supply of roundorsquare recessorsurface mounted rolling type LED Down light with W GU 10 LED Lamp Rib Fabricated from diecast aluminium with white powder coated prewired to mains connector and has swivelling unit of aluminium die cast eye ball and LED Lamp position retained by circular wire spring, with Life of 25000 burning hours and 70percent lumen maintenance with CRI 80. Power Input: 220240V at50or60Hz and Power factor 0.9 along with CE approved. 2years Warranty against any manufacturing defect working under standard electrical conditionLED square or round down light 1012W ---- etc., complete with all leadEach1075.621075.6212.0FalseNoneNoneFalseNoneFalse12907.440
3198268109944NoneItem 11.11.3Supplying and fixing of retrofit type LED bulb W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70percent. efficacy 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322orIEC 60598, LM 79 and LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5percent of lamp wattage., short circuit and open circuit protection to be integrated in the circuit, THD less than 20percent, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABLorCPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.7 W, 6500K ---- etc., complete with all leadEach181.09181.096.0FalseNoneNoneFalseNoneFalse1086.540
3198269109944NoneItem 11.11.5Supplying and fixing of retrofit type LED bulb.W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70percent. efficacy 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322orIEC 60598, LM 79 and LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5percent of lamp wattage., short circuit and open circuit protection to be integrated in the circuit, THD less than 20percent, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABLorCPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.12W, 6500K ---- etc., complete with all leadEach326.94326.944.0FalseNoneNoneFalseNoneFalse1307.760
3198270109944NoneItem 12.46Supplying and Fixing of 70150 Watts lamp holder 2 Pin ---- etc., complete with all leadEach128.83128.8310.0FalseNoneNoneFalseNoneFalse1288.30
3198271109944NoneItem 11.8.2Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr at Lumen Maintenance of 70percent, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP 66 optical and electrical compartment and impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection Min 5KV along with Over voltageor Overload, short circuitor misswiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50or60Hz application. Compliance to IS 10322orIEC 60598, LM 79 and LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with .W System Power consumption. LED Efficiency130lmorw, nominal CRI 75. Luminaire manufacturer should have inhouse facility accredited by NABLorCPRI and any Government certified agency and Design and Development facility certified by ISO 9001:2008 . Housing with supplier word mark orname shall be Engraved or Embossing on the die cast housingor Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer and CreeorNichiaor LumiledsorOsram make LED Source. LED Streetlight 40W ---- etc., complete with all leadNos7282.677282.672.0FalseNoneNoneFalseNoneFalse14565.340
3198272109944NoneItem 6.1Supplying exhaust fan of 1440 RPM of 300mm 12 size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply. ---- etc., complete with all leadEach1813.371813.3710.0FalseNoneNoneFalseNoneFalse18133.70
3198273109944NoneItem 6.3.1Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS3741979 and with double ball bearing system.48" Sweep 1200mm Regular model ---- etc., complete with all leadEach3626.753626.7524.0FalseNoneNoneFalseNoneFalse87042.00
3198274109944NoneItem 13.7.1Fixing all types and all capacities of fluorescent or false ceiling or spot light or CFL or LED fittings indoor on the wall or ceiling or rafters or girders using 23or0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps.On wall or ceiling or Rafter or Girders ---- etc., complete with all leadEach148.27148.2765.0FalseNoneNoneFalseNoneFalse9637.550
3198275109944NoneItem 13.1Fixing a ceiling or Wall mounting fan of all capacities and all types to the existing 'S' hook with fan regulator to the existing board together with supplying and fixing 5 amps. ceiling rose, necessary length of 23 or 0.0076 inch PVC insulated twin twisted copper wire and wiring. ---- etc., complete with all leadEach207.83207.8324.0FalseNoneNoneFalseNoneFalse4987.920
3198276109944NoneItem 13.13Fixing one exhaust fan after making a suitable nitch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 amps, ceiling rose with sufficient length of 23 or 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame. ---- etc., complete with all leadEach859.28859.2810.0FalseNoneNoneFalseNoneFalse8592.80
3198277109944NoneItem 13.4.1Supplying and fixing telescopic M.S. bracket fabricated by using 0.5m length 4” dia telescopic M. S. pipe, with 2 dia 1.5m long M. S. bracket and are welded with suitable angle, using 6mm thick M. S. sheet, grip bolts and nuts, as required, suitable for 9 to 12 Mtrs. M. S. tubular pole, with necessary two coats of painting, with all other acceSingle bracket 1.5 Mtr. Length ---- etc., complete with all leadEach1775.691775.692.0FalseNoneNoneFalseNoneFalse3551.380
3198278109944NoneItem 13.5Fixing halogenormetal halide or SVL or IL or LED floodlight fitting over existing pole or wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires. ---- etc., complete with all leadEach196.89196.892.0FalseNoneNoneFalseNoneFalse393.780
3198279109944NoneItem 5.42.2Fabricating supplying and mounting MS box made out SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour etc., complete16SWG ---- etc., complete with all leadSq CM0.520.5260000.0FalseNoneNoneFalseNoneFalse31200.00
3198280109944NoneItem 5.40.1Supplying amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRPorDMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete.100Amps 4x30x6mm Aluminum Strips ---- etc., complete with all leadm2995.962995.961.0FalseNoneNoneFalseNoneFalse2995.960
3198281109944NoneItem 5.41.1Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 40x40x6mm ---- etc., complete with all leadm370.69370.6910.0FalseNoneNoneFalseNoneFalse3706.90
3198282109944NoneItem 5.41.1Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 50x100x50x6mm C channel ---- etc., complete with all leadm918.84918.8410.0FalseNoneNoneFalseNoneFalse9188.40
3198283109944NoneItem 5.14.7Supplying and fixing Moulded Case Circuit Breaker MCCB .over the existing woodorpanel board using necessary screws, bolts, nuts and wiring complete. Protection of Overload and Short circuit with thermal MagneticorMicro processor release and Earth Fault as per IS13947. lcu= lcs FOUR POLE 63Aor100Amps 25kA ---- etc., complete with all leadEach7396.927396.921.0FalseNoneNoneFalseNoneFalse7396.920
3198284109944NoneItem 5.17.1Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ONorOFF, energy cross3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60632Amps SP ---- etc., complete with all leadEach504.39504.393.0FalseNoneNoneFalseNoneFalse1513.170
3198285109944NoneItem 5.17.4Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ONorOFF, energy cross3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60632Amps DP ---- etc., complete with all leadEach898.18898.181.0FalseNoneNoneFalseNoneFalse898.180
3198286109944NoneItem 5.17.9Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ONorOFF, energy cross3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60 63Amps TPN ---- etc., complete with all leadEach3753.153753.155.0FalseNoneNoneFalseNoneFalse18765.750
3198287109944NoneItem 5.33Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH,KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy ---- etc., complete with all leadEach11321.4511321.451.0FalseNoneNoneFalseNoneFalse11321.450
3198288109944NoneItem 5.38Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12or24v D.C ---- etc., complete with all leadEach625.93625.933.0FalseNoneNoneFalseNoneFalse1877.790
3198289109944NoneItem 5.34Supplying, fixing and wiring 50or5 to 400or5Amps 5VA burden Current Transformer. Class 0.5 accuracy with Tape Wound 48or6.32 ---- etc., complete with all leadEach683.05683.053.0FalseNoneNoneFalseNoneFalse2049.150
3198290109944NoneItem 5.35Supplying, fixing and wiring Electronic Trivector Meter ETV 5 to 32or63 A three phase 4 wire whole current class1 Accuracy Energy Meter ---- etc., complete with all leadEach6933.856933.851.0FalseNoneNoneFalseNoneFalse6933.850
3198291109944NoneItem 9.3.2Supplying, erecting, testing and commissioning of ONLINE UPS system suitable for operation on 230V, 50Hz, AorC supply, with isolation transformer all accessories complete and Excluding batteries and wiring complete.3 kVA ON LINE UPS ---- etc., complete with all leadEach47059.0747059.071.0FalseNoneNoneFalseNoneFalse47059.070
3198292109944NoneItem 9.5.3Supplying, installation, testing and commissioning of 12V DC, AH batteries in poly propylene container for U.P.S. Sealed maintenance free batteries.26 AH capacity ---- etc., complete with all leadEach4388.814388.8116.0FalseNoneNoneFalseNoneFalse70220.960
3198293109944NoneItem 3.6.13RJ45or I.O. outlet ---- etc., complete with all leadEach409.58409.5811.0FalseNoneNoneFalseNoneFalse4505.380
3198294109944NoneItem 3.6.12Telephone socket ---- etc., complete with all leadEach189.6189.610.0FalseNoneNoneFalseNoneFalse1896.00
3198295109944NoneItem 8.1Supplying and drawing UTPCAT 6E LAN cable. ---- etc., complete with all leadm46.1846.18330.0FalseNoneNoneFalseNoneFalse15239.40
3198296109944NoneItem 8.10.1Supplying and Fixing of IorO Socket with back box Single IorO ---- etc., complete with all leadEach595.54595.5411.0FalseNoneNoneFalseNoneFalse6550.940
3198297109944NoneItem 8.4.1Supplying and Fixing of switch mounting rack with power manager and Cable manager 85or11.4 4U with 450mm depth ---- etc., complete with all leadEach5945.735945.731.0FalseNoneNoneFalseNoneFalse5945.730
3198298109944NoneItem 8.9.1116 port 10or100or1000 Switch ---- etc., complete with all leadEach7827.177827.171.0FalseNoneNoneFalseNoneFalse7827.170
3198299109944NoneItem 8.11.1Supplying and fixing of ..mtrs. Cat 6Patch Cable. 2Mtr ---- etc., complete with all leadEach272.24272.2411.0FalseNoneNoneFalseNoneFalse2994.640
3198300109944NoneItem 8.12.316 Port 10or100 patch panel ---- etc., complete with all leadEach3706.973706.971.0FalseNoneNoneFalseNoneFalse3706.970
3198301109944NoneItem 8.13.2Supplying and fixing of MDF krone junction box with KRONE Module or Telephone cable termination. 20 Pair ---- etc., complete with all leadm465.49465.491.0FalseNoneNoneFalseNoneFalse465.490
3198302109944NoneItem MRTELEPHONES Analog push button telephone with Caller ID, flash and radial ---- etc., complete with all leadNos1823.11823.110.0FalseNoneNoneFalseNoneFalse18231.00
3198303109944NoneItem 1.2.2Supplying heavy gauge PVC conduit pipe 25mm dia 2mm thick thick confirming to IS 2509 with suitable size bends, metalorPVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary2or2 ---- etc., complete with all leadm94.894.8420.0FalseNoneNoneFalseNoneFalse39816.00
3198304109944NoneItem 8.2.2Supplying and drawing PVC flexible 2 pair telepone unarmoured tinned copper cable. ---- etc., complete with all leadm25.5225.52200.0FalseNoneNoneFalseNoneFalse5104.00
3198305109944NoneItem 6.7.1Supplying TR split Air conditioners suitable for operation on AorC supply single phase 50 Hz 230 V with hermetically sealed compressor with air cooled condenser, motor capacitor and start run capacitors, relay and over load protector internal unit, with one indoor and one outdoor unit The condenser unit will be placed outside the room on the terrace to avoid noise including standard length of suitable size copper tubing covered with insulation tube. High wall chordedorcordless suitable capacity 3 core sheathedor PVC copper cable and a battery operated wireless remote unit 5star 1 Ton capacity ---- etc., complete with all leadEach50689.4750689.472.0FalseNoneNoneFalseNoneFalse101378.940
3198306109944NoneItem 6.12Installation charges for split type air conditioner with allied works for one indoor and one outdoor unit is to be mounted on suitable Angle Iron support up to 3.0 ton splitorcassette type AorC. ---- etc., complete with all leadEach3258.483258.482.0FalseNoneNoneFalseNoneFalse6516.960
3198307109944NoneItem 9.1.1Supplying, erecting, testing and commissioning of voltage stabilizer suitable for 170 to 270 v in put and load variation from no load to full load, with over load protection, spike suppression, operating at 00 C to 400 C. Range etc., complete.3 KVA Capacity ---- etc., complete with all leadEach4855.524855.522.0FalseNoneNoneFalseNoneFalse9711.040
17169675640000NoneNoneBuildingsDistrict Integrated Public Health Laboratory at GIMS, Gadag- Water Supply and Sanitary Work435861.95
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3198308109945NoneItem 14.28.2.2Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.40mm dia pipes, From wash basin waste lines ---- etc., complete with all leadm111.82111.8230.0FalseNoneNoneFalseNoneFalse3354.60
3198309109945NoneItem 16.7.4Providing and fixing normal gauge polythene pipes of approved quality with special flange compression type fittings of approved make including trench excavation and refilling etc. for EXTERNAL WORKS with:50mm nominal bore pipes, From Sink & Urinal lines ---- etc., complete with all leadm168.94168.9415.0FalseNoneNoneFalseNoneFalse2534.10
3198310109945NoneItem 10.1.5Providing and fixing PVC pipe - OD 75mm and 6 Kg/sqcm, waste lines ---- etc., complete with all leadm267.38267.3840.0FalseNoneNoneFalseNoneFalse10695.20
3198311109945NoneItem 10.1.7Providing and fixing PVC pipe - OD 110mm and 6 Kg/sqcm, sanitary lines ---- etc., complete with all leadm499.52499.5230.0FalseNoneNoneFalseNoneFalse14985.60
3198312109945NoneItem 13.47Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 75mm diameter ---- etc., complete with all leadm239.43239.4330.0FalseNoneNoneFalseNoneFalse7182.90
3198313109945NoneItem 13.48Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 100mm diameter ---- etc., complete with all leadm353.68353.6820.0FalseNoneNoneFalseNoneFalse7073.60
3198314109945NoneItem 14.31Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. ---- etc., complete with all leadNos1361.241361.244.0FalseNoneNoneFalseNoneFalse5444.960
3198315109945NoneItem 13.16Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 ---- etc., complete with all leadEach753.54753.5410.0FalseNoneNoneFalseNoneFalse7535.40
3198316109945NoneItem 14.3Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required ---- etc., complete with all leadEach7288.757288.754.0FalseNoneNoneFalseNoneFalse29155.00
3198317109945NoneItem 13.15Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. ---- etc., complete with all leadNos881.16881.1610.0FalseNoneNoneFalseNoneFalse8811.60
3198318109945NoneItem 14.11.2Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : Size 600x450x200 mm ---- etc., complete with all leadNos6176.666176.664.0FalseNoneNoneFalseNoneFalse24706.640
3198319109945NoneItem 14.7.1Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15mm C.P. brass pillar taps ---- etc., complete with all leadEach3745.863745.862.0FalseNoneNoneFalseNoneFalse7491.720
3198320109945NoneItem 14.22AProviding and fixing CP Brass 32mm size Bottle Trap of approved quality& make and as per the direction of Engineer-in-charge. ---- etc., complete with all leadEach984.47984.476.0FalseNoneNoneFalseNoneFalse5906.820
3198321109945NoneItem 13.8.1.1Providing and fixing Unplasticised P.V.C.connection pipe with brass union 30 cm long 15 mm bore ---- etc., complete with all leadEach100.87100.8710.0FalseNoneNoneFalseNoneFalse1008.70
3198322109945NoneItem 14.37.1Providing and fixing Bottle trap 31mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 gms ---- etc., complete with all leadEach371.91371.916.0FalseNoneNoneFalseNoneFalse2231.460
3198323109945NoneItem 13.28.1Providing and fixing P.T.M.T. extension nipple 15mm ---- etc., complete with all leadEach77.7877.7820.0FalseNoneNoneFalseNoneFalse1555.60
3198324109945NoneItem 13.2.1Providing and fixing brass bib cock of approved quality 15 mm nominal bore ---- etc., complete with all leadNos347.6347.610.0FalseNoneNoneFalseNoneFalse3476.00
3198325109945NoneItem 13.32.1Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.15 mm nominal dia Pipes ---- etc., complete with all leadm375.55375.5520.0FalseNoneNoneFalseNoneFalse7511.00
3198326109945NoneItem 13.32.2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.20 mm nominal dia Pipes ---- etc., complete with all leadm460.63460.6330.0FalseNoneNoneFalseNoneFalse13818.90
3198327109945NoneItem 13.33.2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work)20 mm nominal dia Pipes ---- etc., complete with all leadm263.74263.7430.0FalseNoneNoneFalseNoneFalse7912.20
3198328109945NoneItem 13.33.3Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work)25 mm nominal dia Pipes ---- etc., complete with all leadm359.75359.7520.0FalseNoneNoneFalseNoneFalse7195.00
3198329109945NoneItem 13.4.1Providing and fixing Brass full way valve with C.I. wheel (screwed end) 25 mm dia ---- etc., complete with all leadEach667.25667.258.0FalseNoneNoneFalseNoneFalse5338.00
3198330109945NoneItem 16.9Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.. ---- etc., complete with all leadNos6628.796628.795.0FalseNoneNoneFalseNoneFalse33143.950
3198331109945NoneItem 13.34Providing and placing on terrace (at all floor levels) polyethylene water storage tank,IS:12701 marked,with cover and suitable locking arrangement and making necessary holes for inlet,outlet and overflow pipes but without fittings and the base support for tank. ---- etc., complete with all leadl10.9310.932000.0FalseNoneNoneFalseNoneFalse21860.00
3198332109945NoneItem Approved rateProviding, fixing, testing and commissioning of deep seal PVC multi inlet floor trap of self cleansing design moulded or fabricated with CP grating, rubber ring / solvent cement followed by application of leak proof adhesive like FRP paste including making good the floors etc., complete as directed by the Engineer in charge & approved quality confirming to ISI or BIS Standards ---- etc., complete with all leadNos371.7371.710.0FalseNoneNoneFalseNoneFalse3717.00
3198333109945NoneItem Approved rateAir Vent Cowel75mm ---- etc., complete with all leadm413.0413.010.0FalseNoneNoneFalseNoneFalse4130.00
3198334109945NoneItem Approved rateAir Vent Cowel 110mm ---- etc., complete with all leadm590.0590.05.0FalseNoneNoneFalseNoneFalse2950.00
3198335109945NoneItem Approved rateProviding and fixing testing and commissioning of CP health faucet Hand operated spray unit (instant type) CP Crutch etc., complete as directed by the Engineer in charge. ALD-577 ---- etc., complete with all leadNos1180.01180.04.0FalseNoneNoneFalseNoneFalse4720.00
3198336109945NoneItem Approved rateProviding and fixing, testing and commissioning approved make submersible pump made of C.I Construction suitable for building application. Thequoted rate shall also include for auto lvl.controller. providing necessary safety devices viz. dry run protection, over load relays etc., complete working on 230V, 50Hz, 1Ph, with starter,Duty of Pump : 6.0cum/hr @ 35.0m Head (1 No. Working + 1 No. Stand By) ---- etc., complete with all leadNos23600.023600.02.0FalseNoneNoneFalseNoneFalse47200.00
3198337109945NoneItem Approved rateProviding stoneware gully trap of approved quality and make fixing in M-15 and plastering with CM 1:3 wherever necessary.( Rate includes cost of all materials, fixtures and lead).15cms x 10cms ---- etc., complete with all leadNos3304.03304.04.0FalseNoneNoneFalseNoneFalse13216.00
3198338109945NoneItem Quotation rateThe Tendorer (Agency ) should arrange to obtain (Get) , detailed Architectural drawings and elevations, Structural designs and drawings including Soil exploration & proof checking by IISC IIT NIT or relevant only as decided by the Department and the same has to be furnished to the Department for approval and providing consultancy for Architectural designs & drawings, elevation, 3D view, MFP design and Drawings, Internal and External Electrical services including electrical infrastructure , interior layout and allied works etc., and any other drawings related to this project and 5 sets of as built drawings should be submitted to the employer.etc complete as per the specification and Engineer in charge of work ---- etc., complete with all leadJob120000.0120000.01.0FalseNoneNoneFalseNoneFalse120000.00
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17169675640000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptableNone
17169675640000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of KarnatakaNone
17169675640000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of Karnataka public Procurement on or before the last date and time of bid submission.None
17169675640000NoneNoneELIGIBILITYThe bidder is required to ensure browser compatibility of the computer well in advance to the last date and time for receipt of tenders. The departments shall not be responsible for non-accessibility of Karnataka public Procurement portal due to internet connectivity issues and technical glitches at bidders end.None
17169675640000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejectionNone
17169675640000NoneNoneELIGIBILITYBidder shall pay Contract Management Module processing fees of 0.025% of the contact value (Min Rs.500/- & Max Rs.7500/-) soon after contract has been issued to bidderNone
17169675640000NoneNoneELIGIBILITYThe tenderer shall bear all costs associated with the preparation and submission of his tender, and the employer will in no case be responsible and liable for those costsNone
17169675640000NoneNoneELIGIBILITYConditional tenders will not be acceptedNone
17169675640000NoneNoneELIGIBILITYAll the formats prescribed in the bid document shall be filled by the tenderer in complete mannerNone
17169675640000NoneNoneELIGIBILITYRoyalty on construction materials and other taxes will be deducted as per prevailing Govt., orders as may be modified from time to timeNone
17169675640000NoneNoneELIGIBILITYAny discrepancies observed in the documents uploaded by the tenderer the tender shall liable to rejectedNone
17169675640000NoneNoneELIGIBILITYEarnest Money Deposit will have to be in any one of the forms as per the instructions in the financial bid document and shall have to be valid for 45 days beyond the validity of the tenderNone
17169675640000NoneNoneELIGIBILITYAll formats prescribed in the bid documents shall be filled in complete manner (section 2 & of the bid document)and shall be uploaded properly, signed by tenderer. Necessary certificates shall be uploaded along with the formats wherever required. General documents section can be used for this purposeNone
17169675640000NoneNoneELIGIBILITYTenderers are required to read the Bid Documents carefully before submission of their bidNone
17169675640000NoneNoneELIGIBILITYIf the tenderer quotes bid price below the estimated contract value (Amount put to tender) then the tenderer has to submit the additional security deposit equal to the difference in cost and the additional security deposit should have a validity for the period of executionNone
17169675640000NoneNoneELIGIBILITYIf the numbers of page to be attached in one particular attachment is more, then all the pages can be put into one folder, zipped and then attached or else all the pages can be pasted in one word file and then this word file could be converted to PDF (portable documents format) format and then attached. (Please contract help desk from 9.00 AM to 9.00 PM ( Monday to Saturday) Ph No: 91-8046010000 and 91-8068948777 or send query through Karnataka public procurement portal through query option on or before specified timeNone
17169675640000NoneNoneELIGIBILITYThe Contractor shall strictly take all reasonable steps to protect the environment on and off the site and to avoid damage or nuisance to persons or to property of the public or others resulting from pollution, noise or other causes arising as a consequence of his methods of operationNone
17169675640000NoneNoneELIGIBILITYMaterials like, steel (primary), cement, bitumen etc., required for the work shall be procured by the tenderer themselves and should be got tested positive by the quality control authority before use on the workNone
17169675640000NoneNoneELIGIBILITYTenderer should have latest GST Registration and latest clearance certificate in their nameNone
17169675640000NoneNoneELIGIBILITYThe Rates quoted by the tenderer shall be inclusive of GSTNone
17169675640000NoneNoneELIGIBILITYSpecial Instructions to tenderers - as per bid documentNone
17169675640000NoneNoneELIGIBILITYThe Defects Liability Period is 1 year from the date of completion of the workNone
17169675640001NoneNoneELIGIBILITYTotal value of Civil Engineering Construction works executed in the and payments received in the last five year i.e., 2019-20, 2020-21 2021-22, 2022-23 & 2023-24None
17169675640000NoneNoneELIGIBILITYThe Tenderers are bound to furnish the original certified documents to the employer within 3 days from the day of opening of technical bid for verification, failing which the bid of tenderer will be considered as technically non responsiveNone
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneList of works for which tenders already submittedNoneNone
NoneNoneNoneNoneBanker Details for referenceNoneNone
NoneNoneNoneNoneConstruction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneReports on the financial standing of the tenderer, such as profit and loss statements and auditor’s reports for the last five yearsNoneNone
NoneNoneNoneNoneQualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneList of Financial Resources with CertificatesNoneNone
NoneNoneNoneNoneList of Minimum Key Personnel to be deployed by the contractor at site for Contract work Sl No Position Qualification and Requirement No of Persons. 1) Site Engineer BE Civil with minimum experience of 7 years in the Construction of buildings or Diploma in Civil Engineering with minimum experience of 10 years in the Construction of buildings and should have been working in permanent role of the organization for at least two years 1 (One), 2)Electrical Engineer BE Electrical with minimum experience of 5 years in the Construction of buildings Or Diploma in Electrical Engineering with minimum experience of 10 years in the Construction of buildings and should have been working in permanent role of the organization for at least two years 1 (One).Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Educational and Experience certificates should be uploaded
NoneNoneNoneNoneClause ITT 3.2(b)To qualify for award of this contract, each Tenderer in his/its name should have in the last five years i.e.(2019-20 to 2023-24) The tenderer should have been Satisfactorily completed at least one Satisfactorily completed at least one Similar work of value not less than Rs.55.00 Lakhs as prime contractor. Note : The Work done certificate should be issued by the Officer not less than the rank of Executive Engineer of State or Central Government/ Semi Government/Government undertaking/ autonomous bodies of Government will be considered for the clause 3.2 (b).Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneClause 3.2(c) To qualify for award of this contract, each Tenderer in his/its name should have in the last five years i.e.(2019-20 to 2023-24).Executed in any one year, the following minimum quantities of work Sl. No Description of key items of works Quantity 1)Earthwork Excavation 350.00 Cum,2)RCC and PCC 136.00 Cum,3)Steel Reinforcement for RCC work 15.20 Tonne, 4)Cement Concrete Block Masonry/Solid Block Masonry /Load Bearing Wall/BBM 452.00Sqm, 5)Flooring/Dadooing(Vitrified/Granite/Ceramic/Cement concrete/cladding/dadooing) 350.00 Sqm,6)Plastering 1400.00 Sqm,7)Painting 750.00 Sqm, 8)M.S grill work 745.00 kg 9)WPC 280.00 Sqm Note-The Work done certificate should be issued by the Officer not less than the rank of Executive Engineer of State or Central Government/ Semi Government/Government undertaking/ autonomous bodies of Government will be considered for the clause 3.2(c)Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneClause 3.2(d) The tenderer or his identified sub contractor should possess required valid electrical license for executing building electrification works issued by KPWD/ Government electrical Inspectorate and should have executed similar Building electrical works totaling Rs.6.50 Lakhs in any one financial year.Note-The Work done certificate should be issued by the Officer not less than the rank of Executive Engineer of State or Central Government/ Semi Government/Government undertaking/ autonomous bodies of Government will be considered for the clause 3.2 (d).The letter of willingness of the sub contractor to be engaged for electrical works, should be obtained and uploaded in the KPP-portal.Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneClause 3.2(e)The Tenderer or his identified sub-contractor should possess valid license for executing water supply/sanitary engineering works issued by BWSSB/ KUWS&DB and should have executed similar building water supply/sanitary engineering works totaling Rs.2.50 Lakhs in any one financial year. Note-The Work done certificate should be issued by the Officer not less than the rank of Executive Engineer of State or Central Government/ Semi Government/Government undertaking/ autonomous bodies of Government will be considered for the clause 3.2 (e).The letter of willingness of the sub contractor to be engaged for water supply & Sanitary works, should be obtained and uploaded in the KPP-portal.Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneKPWD Class-III&above Registration Certificate.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Registration certificate issued by competent authority
NoneNoneNoneNoneClause 3.6 Tenderers who meet the above specified minimum qualifying criteria, will only be qualified, if their available tender capacity is more than the total tender value. The available tender capacity will be calculated for prime contractor are as under Assessed available tender capacity AxNx1.5- B Where A maximum value of civil engineering works executed in any one year during the last five years 2019-20 to 2023-24 updated to 2024-25 price level taking into account the completed as well as works in progress. N Number of years prescribed for completion of the works for which tenders are invited. B Value, at 2024- 25 price level of existing commitments and ongoing works to be completed during the next 06 months. Note The statements showing the value of existing commitments and on-going works as well as the stipulated period of completion remaining for each of the works listed should be countersigned by the Employer in charge, not below the rank of an Executive Engineer or equivalent.Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Ongoing work & Existing Commitment works list
NoneNoneNoneNoneClause ITT 3.2(a):To qualify for award of this contract, each Tenderer in his / its name should have in the last five years i.e.(2019-20 to 2023-24).The tenderer should have been achieved in at least two financial years a minimum annual financial turnover (in all classes of civil Engineering construction works only) of Rs.220.00 Lakhs. Note: For Clause 3.2 (a) the Turn over certificate and balance sheet duly certified by the charted accountant is to be submitted.Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNoneClause 3.3(b)Liquid assets and /or availability of credit facilities of not less than Rs.33.00 Lakhs (Credit lines / letter of credit/ certificates from banks for meeting the fund requirement etc.(As per the prescribed format in clause 1.10 of SECTION 3, QUALIFICATION INFORMATION of this document.) as prime Contractor.Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneLine of Credit
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Annual Turnover CertificateTrueTechnical Bid
Work done certificateTrueTechnical Bid
KPWD Registration Certificate Class-III & aboveTrueTechnical Bid
ESI and EPF Certificate and paid receiptTrueTechnical Bid
GST certificate & latest paid receiptTrueTechnical Bid
tenderWorkLocationList
tenderAddress
createdTs1717064703000
version0
createdDateNone
modifiedDateNone
blockNumberOffice of the Chief Engineer, Engineering Wing, Arogya Soudha, 3rd floor, Leprosy Hospital premises, 1st cross, Magadi Road.
streetNone
cityBengaluru
stateKarnataka
pin560023
tenderRecallDTONone