1717416900000 | 0 | None | None | Buildings | Construction of State Reference Standard Laboratory for Legal Metrology Department at Handenahalli Village, Hoskote Taluk, Bengaluru Rural District | 25173142.96 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3225497 | 111217 | None | code01 | Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. - By Mechanical Means using Dozer - In area of light jungle -100 Sqm | Sqm | 408.72 | 408.72 | 8.73 | False | None | None | False | None | False | 3568.1256 | 0 | 3225498 | 111217 | None | code02 | Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. by mechanical means | Cum | 98.8 | 98.8 | 174.53 | False | None | None | False | None | False | 17243.564 | 0 | 3225499 | 111217 | None | code03 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work- In all kinds of soils Depth upto 3 m | Cum | 106.08 | 106.08 | 636.86 | False | None | None | False | None | False | 67558.1088 | 0 | 3225500 | 111217 | None | code04 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.(Page no.7 item 1.9 P.W.D. SR-2021-22 vollume -I) | Cum | 276.64 | 276.64 | 636.86 | False | None | None | False | None | False | 176180.9504 | 0 | 3225501 | 111217 | None | code05 | Filling approved earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | Cum | 450.32 | 450.32 | 3713.6871 | False | None | None | False | None | False | 1672347.574872 | 0 | 3225502 | 111217 | None | code06 | Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications. (Page no.5 item 4.1 P.W.D. SR-2021-22 vollume -II) | Sqm | 122.72 | 122.72 | 554.04 | False | None | None | False | None | False | 67991.7888 | 0 | 3225503 | 111217 | None | code07 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel Reinforcement & formwork shall be paid separately) Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates(The cost including formwork) | Cum | 6067.28 | 6067.28 | 87.41 | False | None | None | False | None | False | 530340.9448 | 0 | 3225504 | 111217 | None | code08 | Providing and laying in position plain cement concrete for levelling course for all works in foundation.The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates (The cost including formwork) Ground Floor | Cum | 10345.09 | 10345.09 | 2.01 | False | None | None | False | None | False | 20793.6309 | 0 | 3225505 | 111217 | None | code09 | Providing and laying in position plain cement concrete for levelling course for all works in foundation.The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates (The cost including formwork) First/Terrace Floor | Cum | 10448.54 | 10448.54 | 5.19 | False | None | None | False | None | False | 54227.9226 | 0 | 3225506 | 111217 | None | code10 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (The cost including formwork) For Footing | Cum | 7116.6 | 7116.6 | 96.77 | False | None | None | False | None | False | 688673.382 | 0 | 3225507 | 111217 | None | code11 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (The cost including formwork) For Column Concrete upto Plinth Beam | Cum | 11202.05 | 11202.05 | 15.12 | False | None | None | False | None | False | 169374.996 | 0 | 3225508 | 111217 | None | code12 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (The cost including formwork) For Retaining Wall | Cum | 7248.38 | 7248.38 | 47.1 | False | None | None | False | None | False | 341398.698 | 0 | 3225509 | 111217 | None | code13 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (The cost including formwork) For Plinth Beam | Cum | 9884.16 | 9884.16 | 42.39 | False | None | None | False | None | False | 418989.5424 | 0 | 3225510 | 111217 | None | code14 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curingand all other appurtenances required to complete the work as per technicalspecifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (The cost including formwork) for Column Concrete Ground Floor | Cum | 12098.42 | 12098.42 | 15.12 | False | None | None | False | None | False | 182928.1104 | 0 | 3225511 | 111217 | None | code15 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curingand all other appurtenances required to complete the work as per technicalspecifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (The cost including formwork) for Column Concrete First/Terrace Floor | Cum | 12219.41 | 12219.41 | 3.46 | False | None | None | False | None | False | 42279.1586 | 0 | 3225512 | 111217 | None | code16 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curingand all other appurtenances required to complete the work as per technicalspecifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (The cost including formwork) for Roof Slab Concrete Ground Floor | Cum | 10675.08 | 10675.08 | 93.37 | False | None | None | False | None | False | 996732.2196 | 0 | 3225513 | 111217 | None | code17 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curingand all other appurtenances required to complete the work as per technicalspecifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (The cost including formwork) for Roof Slab Concrete First/Terrace Floor | Cum | 10781.84 | 10781.84 | 8.4 | False | None | None | False | None | False | 90567.456 | 0 | 3225514 | 111217 | None | code18 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curingand all other appurtenances required to complete the work as per technicalspecifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (The cost including formwork) for Roof Beam, Lintel Concrete Ground Floor | Cum | 11386.75 | 11386.75 | 83.46 | False | None | None | False | None | False | 950338.155 | 0 | 3225515 | 111217 | None | code19 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curingand all other appurtenances required to complete the work as per technicalspecifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (The cost including formwork) for Roof Beam, Lintel Concrete First/Terrace Floor | Cum | 11500.62 | 11500.62 | 7.2 | False | None | None | False | None | False | 82804.464 | 0 | 3225516 | 111217 | None | code20 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curingand all other appurtenances required to complete the work as per technicalspecifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (The cost including formwork) for Chajja Concrete Ground Floor | Cum | 10319.24 | 10319.24 | 1.22 | False | None | None | False | None | False | 12589.4728 | 0 | 3225517 | 111217 | None | code21 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. (The laps and wastages shall not be measured separately) Ground Floor | Tonne | 93035.28 | 93035.28 | 39.46 | False | None | None | False | None | False | 3671172.1488 | 0 | 3225518 | 111217 | None | code22 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. (The laps and wastages shall not be measured separately) terrace Floor | Tonne | 93965.63 | 93965.63 | 1.91 | False | None | None | False | None | False | 179474.3533 | 0 | 3225519 | 111217 | None | code23 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. Ground Floor | Sqm | 1362.4 | 1362.4 | 645.21 | False | None | None | False | None | False | 879034.104 | 0 | 3225520 | 111217 | None | code24 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. First Floor | Sqm | 1376.02 | 1376.02 | 112.32 | False | None | None | False | None | False | 154554.5664 | 0 | 3225521 | 111217 | None | code25 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usagecharges of machinery etc complete as per specifications. | Sqm | 1148.16 | 1148.16 | 51.97 | False | None | None | False | None | False | 59669.8752 | 0 | 3225522 | 111217 | None | code26 | Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer including cost of materials ,labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Sqm | 8607.04 | 8607.04 | 28.5 | False | None | None | False | None | False | 245300.64 | 0 | 3225523 | 111217 | None | code27 | PProviding & fixing of 2-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6 PHR with TPE (Thermo Plastic Elastomer) and lead free, gaskets -grey color having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 44mm width x 40mmheight with reinforcement of 1mm thickness and Sash with overall size of 27mm X 53mm with UPVC honeycomb structure inside in lieu of GI reinforcement. Coextruded Glazing bead for fixing of glass shall be of size 9.5mm x 21.5mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with Crescent Locks. Wall thickness of frame & sash shall be of 2 mm.Maximum possible size 1219mm x 1219mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) | Sqm | 5223.92 | 5223.92 | 43.56 | False | None | None | False | None | False | 227553.9552 | 0 | 3225524 | 111217 | None | code28 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding. | Kgs | 174.72 | 174.72 | 711.0 | False | None | None | False | None | False | 124225.92 | 0 | 3225525 | 111217 | None | code29 | Providing and fixing factory made 18 mm thick single extruded WPC (Wood Polymer Composite) solid plain white colour board Jali, CNC (Computer Numeric Control) routed of approved design by Engineer-incharge which are machine cut for duct/shaft covering, partitions and facades comprising of virgin Polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) minimum compressive strength 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with properties of being termite/borer proof, water/moisture proof and fire retardant and fixing as per requirement at site with necessary stainless steel fasteners and SS screws etc., all complete as per direction of Engineer-In-Charge. (Note: M.S framework required with priming coat shall be paid separately). | Sqm | 4587.44 | 4587.44 | 11.03 | False | None | None | False | None | False | 50599.4632 | 0 | 3225526 | 111217 | None | code30 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately) | Mtr | 730.08 | 730.08 | 34.65 | False | None | None | False | None | False | 25297.272 | 0 | 3225527 | 111217 | None | code31 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. | Sqm | 924.56 | 924.56 | 10.38 | False | None | None | False | None | False | 9596.9328 | 0 | 3225528 | 111217 | None | code32 | Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications | Sqm | 1506.96 | 1506.96 | 322.14 | False | None | None | False | None | False | 485452.0944 | 0 | 3225529 | 111217 | None | code33 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved mak, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete. - Size of Tile 600x600 mm | Sqm | 1222.0 | 1222.0 | 604.04 | False | None | None | False | None | False | 738136.88 | 0 | 3225530 | 111217 | None | code34 | Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : ** Flamed finish granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent. | Sqm | 2564.64 | 2564.64 | 293.03 | False | None | None | False | None | False | 751516.4592 | 0 | 3225531 | 111217 | None | code35 | Providing, laying & fixing cement base, precast, pre polished cement concrete, designer tiles 25mm thick conforming to IS 1237 heavy duty tiles for flooring, treads of steps and landing, laid on a bed of 12mm thick cement mortar 1:3 mis finished with flush pointing using white cement, including cost of materials, mortar, including cutting, griding the edge to half/full round wherever required, labour, curing complete as per specification. | Sqm | 969.28 | 969.28 | 305.56 | False | None | None | False | None | False | 296173.1968 | 0 | 3225532 | 111217 | None | code36 | Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Ceiling Platering Ground Floor | Sqm | 265.2 | 265.2 | 44.0 | False | None | None | False | None | False | 11668.8 | 0 | 3225533 | 111217 | None | code37 | Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Ceiling Platering First Floor | Sqm | 270.5 | 270.5 | 46.2 | False | None | None | False | None | False | 12497.1 | 0 | 3225534 | 111217 | None | code38 | Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Internal Platering Ground Floor | Sqm | 250.64 | 250.64 | 1460.65 | False | None | None | False | None | False | 366097.316 | 0 | 3225535 | 111217 | None | code39 | Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Internal Platering , terrace Floor | Sqm | 253.15 | 253.15 | 120.0 | False | None | None | False | None | False | 30378.0 | 0 | 3225536 | 111217 | None | code40 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.. External Platering , Ground Floor | Sqm | 389.7 | 389.7 | 546.86 | False | None | None | False | None | False | 213111.342 | 0 | 3225537 | 111217 | None | code41 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.. External Platering , Terrace Floor | Sqm | 397.42 | 397.42 | 391.51 | False | None | None | False | None | False | 155593.9042 | 0 | 3225538 | 111217 | None | code42 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 306.8 | 306.8 | 322.14 | False | None | None | False | None | False | 98832.552 | 0 | 3225539 | 111217 | None | code43 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. | Sqm | 104.0 | 104.0 | 1580.65 | False | None | None | False | None | False | 164387.6 | 0 | 3225540 | 111217 | None | code44 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. do- 35 mm thick both side Teak | Sqm | 4713.28 | 4713.28 | 52.0 | False | None | None | False | None | False | 245090.56 | 0 | 3225541 | 111217 | None | code45 | Providing Honne wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. | Cum | 143596.96 | 143596.96 | 1.96 | False | None | None | False | None | False | 281450.0416 | 0 | 3225542 | 111217 | None | code46 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 173.68 | 173.68 | 52.8 | False | None | None | False | None | False | 9170.304 | 0 | 3225543 | 111217 | None | code47 | Hold fasts. | Each | 52.0 | 52.0 | 72.0 | False | None | None | False | None | False | 3744.0 | 0 | 3225544 | 111217 | None | code48 | Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. | Each | 124.8 | 124.8 | 72.0 | False | None | None | False | None | False | 8985.6 | 0 | 3225545 | 111217 | None | code49 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. | Each | 1094.08 | 1094.08 | 72.0 | False | None | None | False | None | False | 78773.76 | 0 | 3225546 | 111217 | None | code50 | Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. complete. | Each | 246.48 | 246.48 | 54.0 | False | None | None | False | None | False | 13309.92 | 0 | 3225547 | 111217 | None | code51 | Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete 250x10mm | Each | 452.4 | 452.4 | 54.0 | False | None | None | False | None | False | 24429.6 | 0 | 3225548 | 111217 | None | code52 | Providing and fixing bright finished brass butt hinges with necessary screws etc. complete 125x70x4 mm (ordinary type). | Each | 191.36 | 191.36 | 54.0 | False | None | None | False | None | False | 10333.44 | 0 | 3225549 | 111217 | None | code53 | Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/ Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge. | Sqm | 849.68 | 849.68 | 554.04 | False | None | None | False | None | False | 470756.7072 | 0 | 3225550 | 111217 | None | code54 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A,including jointing with seal ring conforming to IS : 5382, leaving 10mm gap for thermal expansion,(i) single socked pipes 100mm diameter | Mtr | 302.64 | 302.64 | 166.0 | False | None | None | False | None | False | 50238.24 | 0 | 3225551 | 111217 | None | code55 | Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove. | Mtr | 54.08 | 54.08 | 1500.0 | False | None | None | False | None | False | 81120.0 | 0 | 3225552 | 111217 | None | code56 | Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications. | Cum | 2097.68 | 2097.68 | 4.61 | False | None | None | False | None | False | 9670.3048 | 0 | 3225553 | 111217 | None | code57 | Providing and laying 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per direction of Engineer incharge. Flagging Concrete | Sqm | 832.0 | 832.0 | 94.2 | False | None | None | False | None | False | 78374.4 | 0 | 3225554 | 111217 | None | code58 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two coats applied @ 1.43 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specificationsand as per directions of Engineer-in-charge. | Sqm | 185.12 | 185.12 | 938.37 | False | None | None | False | None | False | 173711.0544 | 0 | 3225555 | 111217 | None | code59 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @ 0.80 ltr/10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 144.56 | 144.56 | 43.56 | False | None | None | False | None | False | 6297.0336 | 0 | 3225556 | 111217 | None | code60 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Special primer applied @ 0.75 ltr /10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 164.32 | 164.32 | 1626.85 | False | None | None | False | None | False | 267323.992 | 0 | 3225557 | 111217 | None | code61 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: | Each | 4415.84 | 4415.84 | 2.0 | False | None | None | False | None | False | 8831.68 | 0 | 3225558 | 111217 | None | code62 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid | Each | 6216.08 | 6216.08 | 4.0 | False | None | None | False | None | False | 24864.32 | 0 | 3225559 | 111217 | None | code63 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : One urinal basin with 5 litre white P.V.C. automatic flushing cistern | Each | 4632.16 | 4632.16 | 2.0 | False | None | None | False | None | False | 9264.32 | 0 | 3225560 | 111217 | None | code64 | White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps | Each | 3205.28 | 3205.28 | 4.0 | False | None | None | False | None | False | 12821.12 | 0 | 3225561 | 111217 | None | code65 | Providing and fixing 7.5cm to 15 cms dia NP grating 100 mm dia. | Each | 156.0 | 156.0 | 20.0 | False | None | None | False | None | False | 3120.0 | 0 | 3225562 | 111217 | None | code66 | KSRB13-8.5 : Providing and fixing to wall, ceiling and floor, medium density polyethylene pipes 6.00 kgf/sq.cm working pressure 50mm outside diameter with special flange, compression type fittings, wall clips, making good the wall, ceiling and floor, including cost of all materials, labour charges, HOM of equipments and testing complete as per specifications. Specification No.KBS 13.2.15.1 / 13.9 for internal water supply connection- 50mm dia | Mtr | 271.44 | 271.44 | 250.0 | False | None | None | False | None | False | 67860.0 | 0 | 3225563 | 111217 | None | code67 | KSRB13-8.5 : Providing and fixing to wall, ceiling and floor, medium density polyethylene pipes 6.00 kgf/sq.cm working pressure 50mm outside diameter with special flange, compression type fittings, wall clips, making good the wall, ceiling and floor, including cost of all materials, labour charges, HOM of equipments and testing complete as per specifications. Specification No.KBS 13.2.15.1 / 13.9 for internal water supply connection- 75mm dia | Mtr | 339.04 | 339.04 | 125.0 | False | None | None | False | None | False | 42380.0 | 0 | 3225564 | 111217 | None | code68 | Supplying UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. for. Pipes of SN4, 110mm dia. for Sanitary line | Mtr | 299.52 | 299.52 | 150.0 | False | None | None | False | None | False | 44928.0 | 0 | 3225565 | 111217 | None | code69 | Providing and fixing to wall, ceiling and floor unplasticised PVC 6.00 kgs/sqcm working pressure with pipe fittings, wall clips etc., and making good to wall, ceiling and floor for sanitary pipelines including cost of all materials, labour charges, HOM of equipments and testing complete as per specifications. 160mm outer dia | Mtr | 578.24 | 578.24 | 50.0 | False | None | None | False | None | False | 28912.0 | 0 | 3225566 | 111217 | None | code70 | Constructing brick masonry chamber of internal dimension 450x450mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover. | Each | 4405.44 | 4405.44 | 6.0 | False | None | None | False | None | False | 26432.64 | 0 | 3225567 | 111217 | None | code71 | Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover. | Each | 5672.16 | 5672.16 | 2.0 | False | None | None | False | None | False | 11344.32 | 0 | 3225568 | 111217 | None | code72 | Providing and constructing of Machinehole chambers conical in shape at top with CC 1:3:6 foundation using 40mm and down size graded metal of approved quality and with an offset of 0.15m alround the chamber and brick masonry in C.M 1:4 plaster with bricks of approved quality and CM plaster 1:3 proportion 12mm thick inside and outside except for the conical surface outside where the thickness of plaster shall be 20 mm thick, with 1 to 6 slope in the concrete towards the central drain, finished smooth and fixing of pipes in CC 1:2:4 with graded metal of 20 mm and down size including supplying and fixing SFRC Machinehole frame and cover confoming to IS 12592(Part-I): 1988 & IS 12592(Part-II) :1991 with latest amendments in CC 1:2:4, supplying and fixing of plastic foot steps staggered at 30cms apart as directed, watering, curing,barricading, danger lighting, pouring tar over M.H. frame and cover, cost of tar, shoring, strutting, dewatering, engraving Machinehole No. on the inner and outer conical surface etc. as per the drawing with all lead and lift for various diameters and depths noted below. With Table Moulded Bricks & Medium Duty SFRC Cover & Frame: For 1.2m dia Constructing Table Moulded Bricks Machinehole 1.2 m internal dia. , 1.0 M depth & Medium duty SFRC cover & frame | Nos | 22763.52 | 22763.52 | 1.0 | False | None | None | False | None | False | 22763.52 | 0 | 3225569 | 111217 | None | code73 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. | Each | 1268.8 | 1268.8 | 4.0 | False | None | None | False | None | False | 5075.2 | 0 | 3225570 | 111217 | None | code74 | Providing and fixing brass bib cock of approved quality. - 15 mm nominal bore | Nos | 297.44 | 297.44 | 10.0 | False | None | None | False | None | False | 2974.4 | 0 | 3225571 | 111217 | None | code75 | Providing and fixing brass bib cock of approved quality. - 20 mm nominal bore | Nos | 317.2 | 317.2 | 10.0 | False | None | None | False | None | False | 3172.0 | 0 | 3225572 | 111217 | None | code76 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20mm | Mtr | 394.16 | 394.16 | 75.0 | False | None | None | False | None | False | 29562.0 | 0 | 3225573 | 111217 | None | code77 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 25 mm | Mtr | 496.08 | 496.08 | 75.0 | False | None | None | False | None | False | 37206.0 | 0 | 3225574 | 111217 | None | code78 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal sibility for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work. 25 mm | Mtr | 307.84 | 307.84 | 75.0 | False | None | None | False | None | False | 23088.0 | 0 | 3225575 | 111217 | None | code79 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal sibility for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work. 32 mm | Mtr | 386.88 | 386.88 | 100.0 | False | None | None | False | None | False | 38688.0 | 0 | 3225576 | 111217 | None | code80 | Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 25 mm nominal bore | Nos | 570.96 | 570.96 | 4.0 | False | None | None | False | None | False | 2283.84 | 0 | 3225577 | 111217 | None | code81 | Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 40 mm nominal bore | Nos | 730.08 | 730.08 | 4.0 | False | None | None | False | None | False | 2920.32 | 0 | 3225578 | 111217 | None | code82 | Providing and fixing unplasticised PVC connection pipe with brass unions : 15 mm nominal bore | Nos | 86.32 | 86.32 | 32.0 | False | None | None | False | None | False | 2762.24 | 0 | 3225579 | 111217 | None | code83 | Providing and fixing unplasticised PVC connection pipe with brass unions : 20 mm nominal bore | Nos | 94.64 | 94.64 | 20.0 | False | None | None | False | None | False | 1892.8 | 0 | 3225580 | 111217 | None | code84 | Providing gun metal pillar cocks 15mm dia of I class conforming to ISI specifications and fixing them in position as per directions including of cost of materials and fixtures and conveyance to spot. | Each | 251.68 | 251.68 | 4.0 | False | None | None | False | None | False | 1006.72 | 0 | 3225581 | 111217 | None | code85 | Providing and fixing brass stop cock of approved quality : 20 mm nominal bore | Nos | 317.2 | 317.2 | 15.0 | False | None | None | False | None | False | 4758.0 | 0 | 3225582 | 111217 | None | code86 | Providing and fixing gun metal non- return valve of approved quality (screwed end) : 25 mm nominal bore - Horizontal | Nos | 644.8 | 644.8 | 15.0 | False | None | None | False | None | False | 9672.0 | 0 | 3225583 | 111217 | None | code87 | Providing and fixing gun metal non- return valve of approved quality (screwed end) : 25 mm nominal bore - Vertical | Nos | 722.8 | 722.8 | 10.0 | False | None | None | False | None | False | 7228.0 | 0 | 3225584 | 111217 | None | code88 | Providing and fixing in position brass ball value high or low pressure with plastic float of approved quality 25mm nominal bore including cost of all materials, labour and HOM of equipments with all leads complete as per specification. 20 mm nominal bore | Set | 326.56 | 326.56 | 3.0 | False | None | None | False | None | False | 979.68 | 0 | 3225585 | 111217 | None | code89 | Providing and fixing in position brass ball value high or low pressure with plastic float of approved quality 25mm nominal bore including cost of all materials, labour and HOM of equipments with all leads complete as per specification. 25 mm nominal bore | Set | 345.28 | 345.28 | 2.0 | False | None | None | False | None | False | 690.56 | 0 | 3225586 | 111217 | None | code90 | Providing and placing on terrace,(All floor levels )polyethylene water storage tank IS :12701 Marked , with cover and suitable locking arrangement and marking necessarry holes for inlet , outlet and over flow pipes but with out fitting andthe base suuport for tank | Ltr | 9.36 | 9.36 | 4000.0 | False | None | None | False | None | False | 37440.0 | 0 | 3225587 | 111217 | None | code91 | Providing, supplying to work site,Single Phase Submersible Pump Sets of 100mm dia (4 inch) suitable for bore well confirming to IS 8034-2000 specifications,with testing of as per instructions of engineer incharge of work and latest amendments - 0.50 HP/0.37kW - 5 STG(stage) | Each | 10576.8 | 10576.8 | 1.0 | False | None | None | False | None | False | 10576.8 | 0 | 3225588 | 111217 | None | code92 | Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : 25 to 40 mm nominal bore | Nos | 632.32 | 632.32 | 25.0 | False | None | None | False | None | False | 15808.0 | 0 | 3225589 | 111217 | None | code93 | Providing NP/CP waste unions conforming to ISI specifications and fixing them in position as per directions including cost of materials, fixtures and conveyance to work spot etc., complete. - for 32mm | Each | 124.8 | 124.8 | 5.0 | False | None | None | False | None | False | 624.0 | 0 | 3225590 | 111217 | None | code94 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. | Sqm | 590.72 | 590.72 | 96.0 | False | None | None | False | None | False | 56709.12 | 0 | 3225591 | 111217 | None | code95 | Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge | Kgs | 141.44 | 141.44 | 720.0 | False | None | None | False | None | False | 101836.8 | 0 | 3225592 | 111217 | None | code96 | Supplying S&S RCC SPUN / VIBRATED CAST PIPES (REINFORCED) pipes NP-3 Class conforming to IS:458-1988 with latest amentments using ordinary portland cement, for sanitary works and conveying to work site, rolling and lowering into trenches, laying true to line and level including loading and unloading at both destinations and jointing of pipes and specials, perfect linking of joints with jack to correct position including cost of jointing
materials, i.e, rubber rings conforming to IS: 5382 for S&S RCC pipes, with all leads and lifts as directed and giving necessary hydraulic test as per ISS to the required pressure and commissioning etc. complete. (Contractor will make his own arrangements for procuring water for testing). Before the execution of the work, the contractor shall carry out the survey. - RCC NP3 Class pipe of 450 mm dia. | Mtr | 2447.12 | 2447.12 | 20.0 | False | None | None | False | None | False | 48942.4 | 0 | 3225593 | 111217 | None | code97 | Providing & fixing 2 mm thick corrugated copper plate in expansion joint complete as per drawing & Technical Specification. | Mtr | 2901.6 | 2901.6 | 44.0 | False | None | None | False | None | False | 127670.4 | 0 | 3225594 | 111217 | None | code98 | Providing and fixing in position 20 mm thick premoulded joint filler in expansion joint for fixed ends of simply supported spans not exceeding 10 m to cater for a horizontal movement upto 20 mm, covered with sealant complete as per drawing and technical specifications. | Mtr | 240.24 | 240.24 | 44.0 | False | None | None | False | None | False | 10570.56 | 0 | 3225595 | 111217 | None | code99 | Providing and fixing of Laterite cladding tiles of size 230x75x10mm thick on 12mm thick cement mortar 1:3 (1 cement : 3 coarse sand) & jointed with Adhesive over rough plaster surface excluding cost of rough plastered surface. The work includes cost of all materials, labour charges for all items of work, usage charges for equipment, etc., complete as per specification. | Sqm | 2265.12 | 2265.12 | 48.0 | False | None | None | False | None | False | 108725.76 | 0 | 3225596 | 111217 | None | code100 | Electrical Work -Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary. 19/20mm dia 2mm thick | Mtr | 66.0 | 66.0 | 400.0 | False | None | None | False | None | False | 26400.0 | 0 | 3225597 | 111217 | None | code101 | Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary. 25mm dia 2mm thick | Mtr | 78.0 | 78.0 | 300.0 | False | None | None | False | None | False | 23400.0 | 0 | 3225598 | 111217 | None | code102 | Groove Cutting in Wall- Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary. 19/20mm dia 2mm thick | Mtr | 68.0 | 68.0 | 400.0 | False | None | None | False | None | False | 27200.0 | 0 | 3225599 | 111217 | None | code103 | Groove Cutting in Wall- Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary. 25 mm dia 2mm thick | Mtr | 79.0 | 79.0 | 250.0 | False | None | None | False | None | False | 19750.0 | 0 | 3225600 | 111217 | None | code104 | Supplying and fixing PVC/metal conduit Deep junction box- 19/20 mm deep Junction box | Each | 49.0 | 49.0 | 15.0 | False | None | None | False | None | False | 735.0 | 0 | 3225601 | 111217 | None | code105 | Supplying and fixing PVC/metal conduit Deep junction box- 25 mm deep Junction box | Each | 56.0 | 56.0 | 10.0 | False | None | None | False | None | False | 560.0 | 0 | 3225602 | 111217 | None | code106 | Point wiring using Copper wire without switch.- Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.- Short point up to 3Mtr from tapping point to out let via switch | Point | 269.0 | 269.0 | 15.0 | False | None | None | False | None | False | 4035.0 | 0 | 3225603 | 111217 | None | code107 | Point wiring using Copper wire without switch.- Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.- Medium point above 3Mtr up to 6Mtr from tapping point to out let via switch | Point | 379.0 | 379.0 | 15.0 | False | None | None | False | None | False | 5685.0 | 0 | 3225604 | 111217 | None | code108 | Point wiring using Copper wire without switch.- Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.- Long point above 6Mtr up to 10Mtr from tapping point to out let via switch | Point | 555.0 | 555.0 | 10.0 | False | None | None | False | None | False | 5550.0 | 0 | 3225605 | 111217 | None | code109 | Point wiring using Copper wire without switch.- Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.-Three outlet in a row, above 6Mts upto 10Mtr from tapping point to out let via switches box | Point | 989.0 | 989.0 | 12.0 | False | None | None | False | None | False | 11868.0 | 0 | 3225606 | 111217 | None | code110 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5 sqmm | Mtr | 26.0 | 26.0 | 400.0 | False | None | None | False | None | False | 10400.0 | 0 | 3225607 | 111217 | None | code111 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.5 sqmm | Mtr | 42.0 | 42.0 | 300.0 | False | None | None | False | None | False | 12600.0 | 0 | 3225608 | 111217 | None | code112 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 6 sqmm | Mtr | 92.0 | 92.0 | 75.0 | False | None | None | False | None | False | 6900.0 | 0 | 3225609 | 111217 | None | code113 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 10 sqmm | Mtr | 167.0 | 167.0 | 75.0 | False | None | None | False | None | False | 12525.0 | 0 | 3225610 | 111217 | None | code114 | Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990- 2C x 1.5 mm2 | Mtr | 53.0 | 53.0 | 300.0 | False | None | None | False | None | False | 15900.0 | 0 | 3225611 | 111217 | None | code115 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall - 3 Way | Each | 159.0 | 159.0 | 10.0 | False | None | None | False | None | False | 1590.0 | 0 | 3225612 | 111217 | None | code116 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall - 4-5 Way | Each | 177.0 | 177.0 | 16.0 | False | None | None | False | None | False | 2832.0 | 0 | 3225613 | 111217 | None | code117 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall - 6 Way | Each | 220.0 | 220.0 | 15.0 | False | None | None | False | None | False | 3300.0 | 0 | 3225614 | 111217 | None | code118 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall - 8 Way | Each | 261.0 | 261.0 | 15.0 | False | None | None | False | None | False | 3915.0 | 0 | 3225615 | 111217 | None | code119 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 3 Module | Each | 161.0 | 161.0 | 10.0 | False | None | None | False | None | False | 1610.0 | 0 | 3225616 | 111217 | None | code120 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 4 Module | Each | 175.0 | 175.0 | 15.0 | False | None | None | False | None | False | 2625.0 | 0 | 3225617 | 111217 | None | code121 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 6 Module | Each | 234.0 | 234.0 | 20.0 | False | None | None | False | None | False | 4680.0 | 0 | 3225618 | 111217 | None | code122 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 8 Module | Each | 285.0 | 285.0 | 25.0 | False | None | None | False | None | False | 7125.0 | 0 | 3225619 | 111217 | None | code123 | Supplying and fixing of modular switch/ Socket/stepped electronic fan regulator/ dimmer/telephone socket etc on existing modular switch plate.. IS 3854 and IS 1293. (16/3.7) 6Amps one way Switch | Each | 102.0 | 102.0 | 130.0 | False | None | None | False | None | False | 13260.0 | 0 | 3225620 | 111217 | None | code124 | Supplying and fixing of modular switch/ Socket/stepped electronic fan regulator/ dimmer/telephone socket etc on existing modular switch plate.. IS 3854 and IS 1293. (16/3.7) 6A Two Way Switch | Each | 166.0 | 166.0 | 16.0 | False | None | None | False | None | False | 2656.0 | 0 | 3225621 | 111217 | None | code125 | Supplying and fixing of modular switch/ Socket/stepped electronic fan regulator/ dimmer/telephone socket etc on existing modular switch plate.. IS 3854 and IS 1293. (16/3.7) 6Amps 3way socket | Each | 171.0 | 171.0 | 15.0 | False | None | None | False | None | False | 2565.0 | 0 | 3225622 | 111217 | None | code126 | Supplying and fixing of modular switch/ Socket/stepped electronic fan regulator/ dimmer/telephone socket etc on existing modular switch plate.. IS 3854 and IS 1293. (16/3.7)Stepped Fan Regulator Two module | Each | 357.0 | 357.0 | 8.0 | False | None | None | False | None | False | 2856.0 | 0 | 3225623 | 111217 | None | code127 | Supplying and fixing of modular switch/ Socket/stepped electronic fan regulator/ dimmer/telephone socket etc on existing modular switch plate.. IS 3854 and IS 1293. (16/3.7) 16Amps one way switch | Each | 180.0 | 180.0 | 8.0 | False | None | None | False | None | False | 1440.0 | 0 | 3225624 | 111217 | None | code128 | Supplying and fixing of modular switch/ Socket/stepped electronic fan regulator/ dimmer/telephone socket etc on existing modular switch plate.. IS 3854 and IS 1293. (16/3.7) 32Amps DP switch | Each | 326.0 | 326.0 | 15.0 | False | None | None | False | None | False | 4890.0 | 0 | 3225625 | 111217 | None | code129 | Supplying and fixing of modular switch/ Socket/stepped electronic fan regulator/ dimmer/telephone socket etc on existing modular switch plate.. IS 3854 and IS 1293. (16/3.7) 6/16Amps universal socket | Each | 236.0 | 236.0 | 20.0 | False | None | None | False | None | False | 4720.0 | 0 | 3225626 | 111217 | None | code130 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit with thermal Magnetic/Micro processor release and Earth Fault as per IS-13947. ( Icu = Ics) FOUR POLE - 250 A 25kA | Each | 21391.0 | 21391.0 | 1.0 | False | None | None | False | None | False | 21391.0 | 0 | 3225627 | 111217 | None | code131 | Supplying and fixing regular MCCB distribution Panel confirming to IS/IEC 61439 - 3 and IK09 tested as per IS/IEC 62262 with minimum IP43 protection provided with Polyurethane (PUR) gasket, with suitable earthing system, on wall/wood board/flush mounting using required cl A , bolts, nuts, etc., with provision for fixing of suitable type capacity MCCB's as an incomer for 3 phase Double door with necessary bus bar completely wired to use on 440V 3phase 4 wire powder coated painting etc., complete with a provision for fixing of single/three phase suitable capacity MCB's as outgoings confirming to IS/IEC 60898 - 12 Way | Each | 15529.0 | 15529.0 | 1.0 | False | None | None | False | None | False | 15529.0 | 0 | 3225628 | 111217 | None | code132 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 - 6-32A SP | Each | 415.0 | 415.0 | 15.0 | False | None | None | False | None | False | 6225.0 | 0 | 3225629 | 111217 | None | code133 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 -40 A DP | Each | 1060.0 | 1060.0 | 5.0 | False | None | None | False | None | False | 5300.0 | 0 | 3225630 | 111217 | None | code134 | Supplying and fixing regular MCB distribution boards on wall/ wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG MS enclosure - 4 Way SP & N | Each | 1241.0 | 1241.0 | 2.0 | False | None | None | False | None | False | 2482.0 | 0 | 3225631 | 111217 | None | code135 | Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, kVA, kWH, kVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy | Each | 9315.0 | 9315.0 | 1.0 | False | None | None | False | None | False | 9315.0 | 0 | 3225632 | 111217 | None | code136 | Supplying and fixing of Metal Socket set of 2pole and earth plugs and socket for incorporating SP and TP MCB (Without MCB).The entire plug and socket shall be mounted in a thermoplastic I powder coated metal box & wired Completely. - 20Amps SP & N | Each | 971.0 | 971.0 | 3.0 | False | None | None | False | None | False | 2913.0 | 0 | 3225633 | 111217 | None | code137 | Supplying and fixing of Modular MCB Devices(Tripper) With Breaking capacity of 6KA- 16-32Amps SP | Each | 210.0 | 210.0 | 1.0 | False | None | None | False | None | False | 210.0 | 0 | 3225634 | 111217 | None | code138 | Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V upto 300mA sensitivity on existing wood/ panel board. - 63 A 2 pole | Each | 5258.0 | 5258.0 | 3.0 | False | None | None | False | None | False | 15774.0 | 0 | 3225635 | 111217 | None | code139 | Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board. | Each | 9255.0 | 9255.0 | 1.0 | False | None | None | False | None | False | 9255.0 | 0 | 3225636 | 111217 | None | code140 | Supplying exhaust fan of 1440 RPM of 300 mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply. | Each | 1492.0 | 1492.0 | 4.0 | False | None | None | False | None | False | 5968.0 | 0 | 3225637 | 111217 | None | code141 | Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/19 and also comply with IS: 1709/1984 with latest amendment, Rated voltage 220 V/50 Hz, Rated power upto 35 W +/- 10 %, Rated current As per IS:374/19, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value 6.2 CMM /W, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet,Class B motor insulation, Bearing Two ball bearings, Top 6202,Bottom 6201, as per IS specification, Motor winding. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 V, Insulation resistance Shall not be less than Two Mega Ohms (2M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, W& current, Air Delivery & Fan Speed as per IS:374/2019 with latest amendment, 2year manufacturer Warranty.(BLDC fans) - 48" Sweep 5 Star (1200 mm) | Each | 2677.0 | 2677.0 | 12.0 | False | None | None | False | None | False | 32124.0 | 0 | 3225638 | 111217 | None | code142 | Supplying wall mounting fan suitable to operate at single- phase 230v AC. supply. - 300mm Sweep | Each | 2492.0 | 2492.0 | 20.0 | False | None | None | False | None | False | 49840.0 | 0 | 3225639 | 111217 | None | code143 | Supplying of .. TR Invertor type split Air conditioners suitable for operation on A/C supply single phase 50 Hz 230 V with hermetically sealed inverter compressor with air cooled condenser, latest R410A / R-32 refrigerant fan motor, start & run capacitors, relay & over load protector internal unit, with one indoor & one outdoor unit The condenser unit will be placed outside the room avoid noise including standard length of suitable size copper tubing covered with nitrile rubber insulation tube. suitable capacity 3 core sheathed/ PVC copper cable and a battery operated wireless remote unit. 5 Star- 1.5 Ton capacity | Each | 56355.0 | 56355.0 | 3.0 | False | None | None | False | None | False | 169065.0 | 0 | 3225640 | 111217 | None | code144 | Supply erection, testing, commissioning of Cassette type split Air conditioner suitable for operation on single/three phase AC supply, hermetically sealed compressor with air cooled condenser motor capacitor start, capacitors run relay and over load protection, one ceiling mounted indoor unit and one outdoor condenser unit including standard accessories covered with insulation tube including battery operated cordless unit.- 2 TR Cassette 1 Ph- 2 Ton capacity | Each | 78815.0 | 78815.0 | 3.0 | False | None | None | False | None | False | 236445.0 | 0 | 3225641 | 111217 | None | code145 | Installation charges for split type air conditioner with allied works for one indoor and one outdoor unit is to be mounted on suitable Angle Iron support upto 3.0 Ton split/cassette type A/C. | Each | 3175.0 | 3175.0 | 5.0 | False | None | None | False | None | False | 15875.0 | 0 | 3225642 | 111217 | None | code146 | Supply of LED Streetlight luminaire with pressure diecast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of antiglare clear diffuser with Injection moulded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70degrees. CCT greaterthan 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire greaterthan IK08. PowerFactor greaterthan0.9 with mains, Surge Protection-Min 5 KV along with Over voltage/Overload, short circuit/miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V50/60 Hz application. Compliance to IS10322/IEC60598, LM79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with........W System Power consumption. LED Efficiency greaterthan1301m/w, nominal CRI greaterthan75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO9001:2008. Housing with supplier wordmark /name shall be Engraved/ Embossing on the diecast housing/Bodypart. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/Lumileds/Osram make LED Source.- LED Streetlight 40W | Each | 4024.0 | 4024.0 | 8.0 | False | None | None | False | None | False | 32192.0 | 0 | 3225643 | 111217 | None | code147 | Supplying, erecting, testing & commissioning of ON-LINE UPS system suitable for operation on 230V, 50Hz, A/C supply, with isolation transformer all accessories complete and Excluding batteries and wiring complete. -10 kVA ON LINE UPS | Each | 103570.0 | 103570.0 | 1.0 | False | None | None | False | None | False | 103570.0 | 0 | 3225644 | 111217 | None | code148 | Supplying, installation, testing & commissioning of 12V DC, AH batteries in poly propylene container for U.P.S. Sealed maintenance free batteries.-100 AH capacity | Each | 12430.0 | 12430.0 | 1.0 | False | None | None | False | None | False | 12430.0 | 0 | 3225645 | 111217 | None | code149 | Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40 mm dia 2.90 mm thick GI pipe 2.5m long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150 mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12 mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia | Nos | 3510.0 | 3510.0 | 5.0 | False | None | None | False | None | False | 17550.0 | 0 | 3225646 | 111217 | None | code150 | Supplying of recess mounting non integrated type LED down light...... W luminaire comprising of pressure decast/ extruded aluminium housing, with spring loaded false ceiling clamps, LED of Power/COB with CCT 6500 degree K, CRI greaterthan 70%. efficacy greaterthan 100 lumen per W, 120degree beam spread, life greaterthan 25000 burning hours and Compliance to IS10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level. LED's are driven by HF electronic driver integrated in a separate control gear assembly., with PF greaterthan 0.95, power loss should lessthan 5% of lamp Wage, short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.-10-12W | Each | 1269.0 | 1269.0 | 25.0 | False | None | None | False | None | False | 31725.0 | 0 | 3225647 | 111217 | None | code151 | Supplying of recess mounting non integrated type LED down light...... W luminaire comprising of pressure decast/ extruded aluminium housing, with spring loaded false ceiling clamps, LED of Power/COB with CCT 6500 degree K, CRI greaterthan 70%. efficacy greaterthan100 lumen per W, 120degree beam spread, life greaterthan 25000 burning hours and Compliance to IS10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level. LED's are driven by HF electronic driver integrated in a separate control gear assembly., with PF greaterthan 0.95, power loss should lessthan 5% of lamp Wage, short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.-15-18W | Each | 1671.0 | 1671.0 | 30.0 | False | None | None | False | None | False | 50130.0 | 0 | 3225648 | 111217 | None | code152 | Supplying of recess mounting non integral type ........ LED w luminaire comprising of pressure decast/extruded aluminium housing, with spring loaded false ceiling clamps, Power LEDs with CCT 6500 degree K, CRIgreaterthan 70%. efficacy greaterthan 100 lumen per W, 120degree beam spread, life greaterthan 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF greaterthan 0.95, power loss should lessthan 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.-LED modular down light 2'x2' 36 W | Each | 4553.0 | 4553.0 | 50.0 | False | None | None | False | None | False | 227650.0 | 0 | 3225649 | 111217 | None | code153 | Supplying of ......feet - PVC Batten with integrated LED tube .....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI greaterthan 80. Power Input: 220-240V @ 50/60Hz & Power factor greaterthan0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.-LED light fighting 1 x4'- 20/22 w | Each | 690.0 | 690.0 | 5.0 | False | None | None | False | None | False | 3450.0 | 0 | 3225650 | 111217 | None | code154 | Fixing all types and all capacities of 1'x4' / 2'x2' LED Light fittings indoor on the wall / ceiling / rafters / girders with necessary supporting frame, using 2310.0076" twin twisted PVC insulated wires, required Nos of round blocks and clamps. | Each | 490.0 | 490.0 | 5.0 | False | None | None | False | None | False | 2450.0 | 0 | 3225651 | 111217 | None | code155 | Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling / rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clamps.-On wall/ ceiling / Rafter / Girders | Each | 122.0 | 122.0 | 90.0 | False | None | None | False | None | False | 10980.0 | 0 | 3225652 | 111217 | None | code156 | Fixing a ceiling /wall mounting fan of all capacities and all types, with necessary clamps and 'S' hook made out of 15mm dia MS rod, with 5 A. ceiling rose of approved quality with necessary length of 23/0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size wooden board and wired. | Each | 315.0 | 315.0 | 33.0 | False | None | None | False | None | False | 10395.0 | 0 | 3225653 | 111217 | None | code157 | Fixing one exhaust fan in the nitch already left in the wall with bolts and nuts and 5 A. ceiling rose with sufficient length of 23/0.0076 inch PVC insulated twin core wire. | Each | 492.0 | 492.0 | 4.0 | False | None | None | False | None | False | 1968.0 | 0 | 3225654 | 111217 | None | code158 | Supply, installation of 4kg Fire Extinguisher Mono Ammonium Phosphate Powder 50, Stored Pressure Type, Pressure Gauge, Gross Weight 6.9 Kg, empty weight 2.9 Kg, Can Height 440MM, Diameter 140MM, Discharge Time less than 13 Sees, Controllable discharge mechanism (Squeeze grip with easy snap safety seal), Range minimum 4 meters, applicable on Class A,8, C and electrically started Fire, A Rating 2A, 8 Rating 218, Can construction : Deep drawn & Co., Mig welded, valve Construciton : Forging and Mechining, Internal Coating of Can: Epoxy powder coating, External Coating of Can: Epoxy Polyster power coating, Sheet metal thickness: 1.60MM, 5 years Warranty with installation system with Superior quality EPDM Rubber Hosepipe etc., including cost of supporting materials like MS stand & accessaries if it is fixing n floor / MS brackets & accessories if it is fixing on wall, , labour, usage charges of machinery complete as per specifications. complete IS 15683, CE Approved. | Each | 2650.0 | 2650.0 | 10.0 | False | None | None | False | None | False | 26500.0 | 0 | 3225655 | 111217 | None | code159 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 (ESCOM SR 2023-24, Item code 32, Page No.13)-4 core 10 sqmm, (10 GI Strips - 4 x 0.8 mm) | Km | 118004.0 | 118004.0 | 0.03 | False | None | None | False | None | False | 3540.12 | 0 | 3225656 | 111217 | None | code160 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 (ESCOM SR 2023-24, Item code 32, Page No.13)-16 Sqmm, 4 Core, (11 GI Strips - 4 x 0.8 mm) | Km | 141842.0 | 141842.0 | 0.03 | False | None | None | False | None | False | 4255.26 | 0 | 3225657 | 111217 | None | code161 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 (ESCOM SR 2023-24, Item code 32, Page No.13)-25 Sqmm, 3.5 Core, (12 GI Strips - 4 x 0.8 mm) | Km | 139549.0 | 139549.0 | 0.05 | False | None | None | False | None | False | 6977.45 | 0 | 3225658 | 111217 | None | code162 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 (ESCOM SR 2023-24, Item code 32, Page No.13)-3.5 core 50 sqmm, (16 GI Strips - 4 x 0.8 mm) | Km | 178973.0 | 178973.0 | 0.05 | False | None | None | False | None | False | 8948.65 | 0 | 3225659 | 111217 | None | code163 | HDPE/PLB Pipe 40/33 mm - (ESCOM SR 2023-24, Item code 66.05, Page No.30) | Mtr | 62.34 | 62.34 | 160.0 | False | None | None | False | None | False | 9974.4 | 0 | 3225660 | 111217 | None | code164 | Laying of UG Cable of various sizes using Winch Machine (ESCOM SR 2023-24, Item code 28.05, Page No.56) | Mtr | 239.0 | 239.0 | 160.0 | False | None | None | False | None | False | 38240.0 | 0 | 3225661 | 111217 | None | code165 | Heavy Duty Copper Terminal Long Barrel Lugs (Pg.No 26) | Nos | 40.0 | 40.0 | 5.0 | False | None | None | False | None | False | 200.0 | 0 | 3225662 | 111217 | None | code166 | Fabricating supplying and mounting MS box made out ...SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete- 16SWG | Sq CM | 0.38 | 0.38 | 20001.0 | False | None | None | False | None | False | 7600.38 | 0 | 3225663 | 111217 | None | code167 | Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work. (pg.no 6) | Cum | 484.0 | 484.0 | 9.0 | False | None | None | False | None | False | 4356.0 | 0 | 3225664 | 111217 | None | code168 | Interior Work- Providing and fixing tiled false ceiling of specified materials of size 595x595mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 g/m2, both side inclusive) consisting of main ""T"" runner with suitably spaced jointsto get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross ""T"" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main ""T"" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross ""T"" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main ""T"" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GIadjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T- sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings
and as directed by Engineer-in-charge. - GI Metal Ceiling Lay in plain Tegular edge Global white color tiles of size 595x595 mm, and 0.5 mm thick with 8 mm drop; made of G I sheet having galvanizing of 100 g/m2 (both sides inclusive) and electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending. | Sqm | 1605.76 | 1605.76 | 554.04 | False | None | None | False | None | False | 889655.2704 | 0 | 3225665 | 111217 | None | code169 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-incharge. (Glazing, paneling and dash fasteners to be paid for separately) :For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Powder coated aluminium (minimum thickness of powder coating 50 micron) including cost of materials, labour, usage charges of machinery complete as per specifications. | Kgs | 593.84 | 593.84 | 309.13 | False | None | None | False | None | False | 183573.7592 | 0 | 3225666 | 111217 | None | code170 | Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer- in-charge: Pre-laminated particle board with decorative lamination on both sides including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Sqm | 1022.32 | 1022.32 | 104.31 | False | None | None | False | None | False | 106638.1992 | 0 | 3225667 | 111217 | None | code171 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness (weight not less than 10kg/ m²) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of theEngineer-in-Charge. | Sqm | 1027.52 | 1027.52 | 74.7 | False | None | None | False | None | False | 76755.744 | 0 | 3225668 | 111217 | None | code172 | Providing & Fixing in position Acoustical wall panelling with Integral Densified Square/Butt edged Fully Perforated Eco Friendly Lightweight Calcium Silicate panels/tiles with fabricated galvanised mild steel frame work for Auditoriums, Community halls, Offices, Institutions, Airports, Meeting halls, Indoor Stadiums and Studios. The Eco Friendly Lightweight Calcium Silicate wall panels/tiles shall be made from Non Cementitious Hydrated Calcium Silicate Slurry/Mixture, Reinforced recycled material with fibers and natural fillers. Free from Formaldehyde and other harmful materials. | Sqm | 3042.0 | 3042.0 | 49.28 | False | None | None | False | None | False | 149909.76 | 0 | 3225669 | 111217 | None | code173 | Compound wall - Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work- In all kinds of soils Depth upto 3 m | Cum | 106.08 | 106.08 | 578.25 | False | None | None | False | None | False | 61340.76 | 0 | 3225670 | 111217 | None | code174 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel Reinforcement & formwork shall be paid separately) Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates(The cost including formwork) | Cum | 6067.28 | 6067.28 | 56.54 | False | None | None | False | None | False | 343044.0112 | 0 | 3225671 | 111217 | None | code175 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (The cost including formwork) For Footing Raft | Cum | 7116.6 | 7116.6 | 77.1 | False | None | None | False | None | False | 548689.86 | 0 | 3225672 | 111217 | None | code176 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (The cost including formwork) For Retaining Wall | Cum | 7248.38 | 7248.38 | 134.93 | False | None | None | False | None | False | 978023.9134 | 0 | 3225673 | 111217 | None | code177 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. (The laps and wastages shall not be measured separately) | Tonne | 82171.44 | 82171.44 | 21.2 | False | None | None | False | None | False | 1742034.528 | 0 | 3225674 | 111217 | None | code178 | Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in- Charge. | Kgs | 141.44 | 141.44 | 720.0 | False | None | None | False | None | False | 101836.8 | 0 | 3225675 | 111217 | None | code179 | Pathway- Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of
unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. - By Mechanical Means using Dozer - In area of light jungle-100 Sqm | Sqm | 408.72 | 408.72 | 0.98 | False | None | None | False | None | False | 400.5456 | 0 | 3225676 | 111217 | None | code180 | Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work.- In all kinds of soils upto 300 mm depth | Cum | 98.8 | 98.8 | 30.6 | False | None | None | False | None | False | 3023.28 | 0 | 3225677 | 111217 | None | code181 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates | Cum | 5890.56 | 5890.56 | 10.5 | False | None | None | False | None | False | 61850.88 | 0 | 3225678 | 111217 | None | code182 | Construction of cement concrete kerb with top and bottom width 115 and 165 mm respectively, 250 mm high in M 15 grade foundation 150 mm thick, foundation having 50 mm projection beyond kerb stone, kerb stone laid with kerb laying machine, foundation concrete laid manually, all complete as per clause 409- M15 grade for kerb base | Mtr | 248.56 | 248.56 | 60.0 | False | None | None | False | None | False | 14913.6 | 0 | 3225679 | 111217 | None | code183 | Providing and laying 80mm thick factory made precast M -30 grade Cement Concrete Paver Block as per IRC SP 63:2018 & IS 15658 for Commercial Traffic Axle load repetitions upto 10MSA & for Residential Streets of approved shape and colour, laid in required pattern and including over 40mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge. (WMM/WBM Base to be paid separately as per relevant technical specification) | Sqm | 1207.44 | 1207.44 | 90.0 | False | None | None | False | None | False | 108669.6 | 0 |
|