tenderSubEstimateList | createdTs | version | createdDate | modifiedDate | workCategoryName | subEstimateName | estimateTotal | itemList |
---|
1717495924000 | 0 | None | None | Buildings | Providing Additional 1000 KVA TC, LT Control Panel Board, Construction of HT Yard & Control Panel Room and allied works to MIMS Teaching Hospital at Mandya (Civil Works) | 626181.4 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3228657 | 111340 | None | item no:1.3 PWD SR 2023-24 | Earth work in surface excavation by manual means for lowering & levellingthe ground by chiselling and wedging in Hard rock for all works other thanfoundation & depth not exceeding 100 mm as per drawing and technicalspecifications, including setting out, barricading, caution lights, dressing ofexcavated surfaces, disposing off the excavated spalls/stuff & stacking the
selected spall/ stuff for reuse in a radius of 50 m and lift upto 1.5 m includingcost of labour, tools, usage & other appurtenances required to complete thework. | Cum | 215.13 | 215.13 | 60.0 | False | None | None | False | None | False | 12907.8 | 0 | 3228658 | 111340 | None | item no:1.4.1 PWD SR 2023-24 | Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and suchsimillar works in all kinds of soils, as per drawing and technical specifications,including setting out, shoring, strutting, barricading, caution lights, removalof stumps and other deleterious matter, excavated surface leveled and sidesneatly dressed disposing off the excavated stuff or sorting & stacking theselected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost oflabour, tools & other appurtenaces required to complete the work. | Cum | 294.13 | 294.13 | 10.0 | False | None | None | False | None | False | 2941.3 | 0 | 3228659 | 111340 | None | item no: 2.1.2 PWD SR 2023-24 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machine mixed, laid inlayers not exceeding 150 mm thickness, well compacted using plate vibrators,including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete thework as per technical specifications.Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates | Cum | 6884.03 | 6884.03 | 2.5 | False | None | None | False | None | False | 17210.075 | 0 | 3228660 | 111340 | None | item no: 2.1.6 PWD SR 2023-24 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machine mixed, laid inlayers not exceeding 150 mm thickness, well compacted using plate vibrators,including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete thework as per technical specifications.Mix 1:2:4 Using 20 mm nominal size graded crushed coarse aggregates | Cum | 7587.74 | 7587.74 | 7.5 | False | None | None | False | None | False | 56908.05 | 0 | 3228661 | 111340 | None | item no: 11.62 PWD SR 2023-24 | Supplying and fixing RCC precast fencing pole of size 0.15mx0.15mx2.0m casted in M 20 with 20mm down size aggregates making holes for drawingbarbed wire at 30 cm c/c using 8 mm dia vertical 4 TMT steel rods and6 mm dia stirups at 15 cm c/c fixed 1.5 m above Ground level using steelmoulding , curing , transportation to work spot including excavation in alltypes of soil, fixing in plain cement concrete M15 using 20 mm downsizeaggregate including aligning to plumb and line providing including costof all materials, labour,usage charges of machinery complete. | Each | 1318.71 | 1318.71 | 82.0 | False | None | None | False | None | False | 108134.22 | 0 | 3228662 | 111340 | None | item no: 11.60 PWD SR 2023-24 | Providing and fixing G.I. chain link fabric fencing of required width in meshsize 25x25 mm made of G.I. wire of dia 3 mm including strengthening with2 mm dia wire or nuts, bolts and washers as required complete as per thedirection of Engineer-in-charge. | Sqm | 1085.35 | 1085.35 | 144.0 | False | None | None | False | None | False | 156290.4 | 0 | 3228663 | 111340 | None | item no: 4.1ii PWD SR 2023-24 | Construction of Granular Sub-Base of required grading as pe design mixing in a mechanical mix plant at OMC, carriageof mixed Material to work site, spreading in uniform layerswith motor grader on prepared surface and compacting withvibratory power roller to achieve the desired density, completeas per clause 401-For Grading -II Material | Cum | 3111.42 | 3111.42 | 60.0 | False | None | None | False | None | False | 186685.2 | 0 | 3228664 | 111340 | None | item no: 11.16.2 PWD SR 2023-24 | Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer,including welding and bolted with special shaped washers etc. complete.
Hot finished seamless type tubes including cost of materials, labour, usagecharges of machinery complete as per specifications and as per directionsof the Engineer-in-Charge. | Kgs | 178.66 | 178.66 | 132.3 | False | None | None | False | None | False | 23636.718 | 0 | 3228665 | 111340 | None | item no: 8.40 PWD SR 2023-24 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work afterthoroughly brooming the surface to remove all dirt, dust, mortar dropsand foreign matter including preparing the surface even and sand papersmooth, cost of materials, labour complete as per specifications and as perdirections of Engineer-in-charge. | Sqm | 139.77 | 139.77 | 7.6 | False | None | None | False | None | False | 1062.252 | 0 | 3228666 | 111340 | None | item no:15.21 Ele SR 2023-24 | Supply and installation of 9Kg Powder Based stored presure type melting
point at 1200 degree C, Applicable on Class D metal fires in heavy metals,
alkali metals and alloys Pressure Guage, Gross Weight 14.9Kg, empty
weight 5.90 Kg, Can Height 615MM, Diameter 175 MM, Discharge Time
less than 18 Sees, Controllable discharge mechanism (Squeeze grip with easy
snap safety seal), Range minimum4meters, Canconstruction: Deepdrawn&
Co., Mig welded, valve Construciton: Forging and Mechining, Internal
Coating of Can: Epoxy powder coating, External Coating of Can: Epoxy
Polyster power coating, Sheet metal thickness: 2.00 MM, 5 years warranty
with instalert system with Superior quality EPDM Rubber Hosepipe etc.,
including cost cost of supporting materials like MS stand & accessaries
if it is fixing n floor / MS brackets & accessories if it is fixing on wall,,
labour, usage charges of machinery complete as per specifications. complete
CE Approved. | Each | 13977.1 | 13977.1 | 4.0 | False | None | None | False | None | False | 55908.4 | 0 | 3228667 | 111340 | None | item no:15.111 PWD SR 2023-24 | Supplying of four bucket stand alongwith buckets. Complete | Each | 2248.49 | 2248.49 | 2.0 | False | None | None | False | None | False | 4496.98 | 0 |
| 1717495924000 | 0 | None | None | Buildings | Providing Additional 1000 KVA TC, LT Control Panel Board, Construction of HT Yard & Control Panel Room and allied works to MIMS Teaching Hospital at Mandya (Electrical Works) | 14535185.39 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3228668 | 111341 | None | CESC SR III a | Pre - Stressed Tubular Spun Pole 11 Mtr Long - 500 Kg WL with Labour Charges | No | 23820.66 | 23820.66 | 2.0 | False | None | None | False | None | False | 47641.32 | 0 | 3228669 | 111341 | None | CESC SR 2 IX a | 11 kV, Horizontal Cross Arm with HT Single Top supports, clamps, bolts, nuts & washers - MS For RCC Pole with Labour Charges | No | 932.2 | 932.2 | 4.0 | False | None | None | False | None | False | 3728.8 | 0 | 3228670 | 111341 | None | CESC SR 3 XIX f | 45 KN Disc Insulator Porcelain | Set | 554.6 | 554.6 | 12.0 | False | None | None | False | None | False | 6655.2 | 0 | 3228671 | 111341 | None | CESC SR 3 XIX e | 11 kV, 5 KN Composite/Polymeric Pin Insulator (24 mm Dia FRP Rod) | No | 260.78 | 260.78 | 6.0 | False | None | None | False | None | False | 1564.68 | 0 | 3228672 | 111341 | None | CESC SR 3 XX b | ACSR conductor as per IS : 398 (Part - 2/1996)are the latest revision Rabbit ACSR (6/3.35 mm Al+1/3.35 mm St), Std Wt: 214 Kg/KM | Km | 76480.52 | 76480.52 | 0.1 | False | None | None | False | None | False | 7648.052 | 0 | 3228673 | 111341 | None | CESC SR XXXII | DOLO Cut Out with Labour Charges | No | 1427.8 | 1427.8 | 1.0 | False | None | None | False | None | False | 1427.8 | 0 | 3228674 | 111341 | None | CESC SR 5 151 17.01 | LT Protection Kit (Dwg No. BESCOM/GM/QS&S/10 Dtd 24.11.2018 with Labour charges | No | 2566.5 | 2566.5 | 1.0 | False | None | None | False | None | False | 2566.5 | 0 | 3228675 | 111341 | None | CESC SR 17 444 55.01 | Transparent Alkathine tube 19 mm dia, 2 mm thick in coils of 30 Mtr | m | 594.72 | 594.72 | 30.0 | False | None | None | False | None | False | 17841.6 | 0 | 3228676 | 111341 | None | CESC 5 131 13.10 | Distribution Transformer - 3 Phase 11kV/433V - Amorphous Core with Oil as per IS-1180 (Part-1): 2014 (CESC SR 5/130/ 13.08) B. CABLE ENTRY TYPE. 500 kVA, Aluminium Wdg, Star 2 (5 Star) | Each | 1114274.0 | 1114274.0 | 2.0 | False | None | None | False | None | False | 2228548.0 | 0 | 3228677 | 111341 | None | CESC 2 54 3.02 | Erection of Double Pole Transformer Structure using 9 Mtr Long RCC (145 Kg WL)/PSCC (300 Kg WL) Pole including fixing of Structure Materials, Erection of Poles etc., complete for mounting of Transformer as per approved drawing Above 250 kVA | Per Structure | 5744.24 | 5744.24 | 2.0 | False | None | None | False | None | False | 11488.48 | 0 | 3228678 | 111341 | None | 20 509 61.01 | 11 kV HT Metering cubicle of different CT Ratio, Both side cable entry type with 3 CT & 3 PT, With Transparent Cover TTB, with 30x8 mm Copper Busbar, Modem & 2 No of Meters for 3 Phase 4 Wire Metering without Load Break Switch (HT Metering Box Fabricated out of 3 mm MS Sheet duly epoxy powder coated) as per revised Specification (Dwg No. BESCOM/GM/QS&S/-- Dtd 24.11.2018) | Unit | 288840.4 | 288840.4 | 1.0 | False | None | None | False | None | False | 288840.4 | 0 | 3228679 | 111341 | None | 4 P-97 I-8.01 | Erection of HT metering Cubicle on Platform | No | 2036.68 | 2036.68 | 1.0 | False | None | None | False | None | False | 2036.68 | 0 | 3228680 | 111341 | None | P-283 I-38.01 | Conventional RMU (VCB Type) with Copper Busbar, 350 MVA, 630 Amps as per IEC- 62271/IS-3427 3 Way RMU, 2OD + 1VL (One Incomer + One Breakers + One Outgoing) | Unit | 1673825.28 | 1673825.28 | 1.0 | False | None | None | False | None | False | 1673825.28 | 0 | 3228681 | 111341 | None | CESC SR 10 P-272 I-36.05 | 11 kV, 3 Core, XPLE HTUG Cable with pressure extruded inner sheeth, ROUND WIRE ARMOURED as per IS-7098 (Part-2) Armouring wires dia and Resistivity as per IS-3975 ( 240 Sqmm, (55 GI Wires - 3.15 mm Dia) | Km | 2441776.36 | 2441776.36 | 0.2 | False | None | None | False | None | False | 488355.272 | 0 | 3228682 | 111341 | None | CESC SR 9 P-226 I-31.02 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 3x185 to 240 Sqmm | Km | 56404.0 | 56404.0 | 0.2 | False | None | None | False | None | False | 11280.8 | 0 | 3228683 | 111341 | None | BESCOM P.No 8 P-202 I-29.03 | Earth work excavation for cable trench of 0.5 to 0.75 Mtr. Width and Depth upto 1 Mtr including trial pits, depositing on bank upto a lead of 50 Mtr, Supplying and Displaying necessary Danger Boards and Lighting, Using sight Rails and Sign Boards at every 100 Mtr wherever necessary as directed In Hard Soil | Cum | 459.02 | 459.02 | 1275.0 | False | None | None | False | None | False | 585250.5 | 0 | 3228684 | 111341 | None | CESC SR 15 P-363 I-45.08 | Heat Shrinkable Outdoor Type Cable Termination Kit for XLPE Cable 3x240 Sqmm | Set | 6120.66 | 6120.66 | 2.0 | False | None | None | False | None | False | 12241.32 | 0 | 3228685 | 111341 | None | CESC SR 15 P-360 I-45.04 | Heat Shrinkable Indoor Type Cable Termination Kit for XLPE Cable 3x240 Sqmm | Set | 5398.5 | 5398.5 | 16.0 | False | None | None | False | None | False | 86376.0 | 0 | 3228686 | 111341 | None | CESC SR 11 P-306 I-35.05 | Fixing of Termination Kit | No | 411.82 | 411.82 | 18.0 | False | None | None | False | None | False | 7412.76 | 0 | 3228687 | 111341 | None | S.R | Heavy Duty Copper Terminal Long Barrel. 240 Sqmm Copper Terminal, Apprx Wt: 218 Gm | No | 434.24 | 434.24 | 48.0 | False | None | None | False | None | False | 20843.52 | 0 | 3228688 | 111341 | None | S.R | Construction of platform with size stone, cement concert for erection of 500 kVA Transformer/Metering cubicle/Heavy Equipment.Construction of platform (1.5x1.5x1.2) Mtr in size stone, for erection of transformers/Heavy equipment including all materials, labour. Excavation of (1.5x1.5x1) Mtr pit for foundation providing and laying cement concrete 1:4:8 for foundation laid in 10 cm thick layers, well compacted curing etc., complete providing and construction of stone masonary 0.9 Mtr below ground level and 1.2 Mtr above ground level neatly hammer dressed in cement morter 1:6. Providing and Laying cement concrete slab 1.5x1.5x0.10 Mtr with cement concrete of 1:2:4 mix forming & cutting complete, providing pointing to stone masonary in cement morter 1:3 after racking joint & nisely lining curing etc., plastering the concrete surfaces in cement morter 1:4 including smooth randering curing etc., curing at every stages completely. | Per Structure | 35825.98 | 35825.98 | 3.0 | False | None | None | False | None | False | 107477.94 | 0 | 3228689 | 111341 | None | 17 P-439 I-54.01 | GI Grounding pipe, B - Class, 42 mm dia, 2.5 Mtr long, 3.2 mm thick with bolt, nut, GI Strips and washer complete Minimum Weight of GI Pipe: 7.3 Kg | No | 908.6 | 908.6 | 35.0 | False | None | None | False | None | False | 31801.0 | 0 | 3228690 | 111341 | None | 17 P-440 I-54.02 | Good Quality well burnt Charcoal for grounding purposes packed in non returnable gunny bag of 30 Kg each | No | 778.8 | 778.8 | 35.0 | False | None | None | False | None | False | 27258.0 | 0 | 3228691 | 111341 | None | 17 P-441 I-54.03 | Good Quality Salt for grounding purposes packed in 50 Kg gunny bag | Bag | 357.54 | 357.54 | 35.0 | False | None | None | False | None | False | 12513.9 | 0 | 3228692 | 111341 | None | 17 P-442 I-54.04 | Rod type of earthing using 40 mm Dia, 3 Mtr long MS rod as ground rod, in earth pit of 300 mm width and 3300 mm depth and using 50x6 mm flat welded to ground rod as terminal & connected to equipment ground terminal using PVC Al wire as specified | No | 2658.54 | 2658.54 | 35.0 | False | None | None | False | None | False | 93048.9 | 0 | 3228693 | 111341 | None | 17 P-443 I-54.05 | Bentonite clay slurry for earthing in 50 Kg Bag | No | 423.62 | 423.62 | 35.0 | False | None | None | False | None | False | 14826.7 | 0 | 3228694 | 111341 | None | P-II Item No.30 | Supplying of 40mm& down size granite metal jelly and spreading to the TC yard etc., as per ISI and ISo (888*1.03) | Cum | 1079.28 | 1079.28 | 10.0 | False | None | None | False | None | False | 10792.8 | 0 | 3228695 | 111341 | None | Civil SR P-9 P-11.58 | Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction ofEngineer-in-charge. (Made of G.I. wire of dia 4 mm) | Sqm | 797.68 | 797.68 | 100.0 | False | None | None | False | None | False | 79768.0 | 0 | 3228696 | 111341 | None | Civil Sr P-80 I-11.15.1 | Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitr ed, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer: Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) including cost of materials, labour, usage charges of machinery complete as per specifications /and as per directions of the Engineer-in-Charge. | Kg | 135.7 | 135.7 | 150.0 | False | None | None | False | None | False | 20355.0 | 0 | 3228697 | 111341 | None | Civil SR 90 I-2.2.1.1 | Spun Pole Concrete Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 7352.58 | 7352.58 | 5.0 | False | None | None | False | None | False | 36762.9 | 0 | 3228698 | 111341 | None | P-12 I-5.14.7 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short- icrcuit/Over Load. ForMicroprocessor MCCBS Facility for segregating Priority andNon-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between frontcover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all thepoles simultaneously and they shall have a single mechanism. FOUR POLE 100 A 25 kA | Each | 9752.7 | 9752.7 | 40.0 | False | None | None | False | None | False | 390108.0 | 0 | 3228699 | 111341 | None | P-12 I-5.14.8 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short- icrcuit/Over Load. ForMicroprocessor MCCBS Facility for segregating Priority andNon-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between frontcover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all thepoles simultaneously and they shall have a single mechanism. 125 A 25 kA | Each | 11884.96 | 11884.96 | 9.0 | False | None | None | False | None | False | 106964.64 | 0 | 3228700 | 111341 | None | P-12 I-5.14.9 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short- icrcuit/Over Load. ForMicroprocessor MCCBS Facility for segregating Priority andNon-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between frontcover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all thepoles simultaneously and they shall have a single mechanism. 160 A 25 kA | Each | 14827.88 | 14827.88 | 7.0 | False | None | None | False | None | False | 103795.16 | 0 | 3228701 | 111341 | None | P-12 I-5.14.10 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short- icrcuit/Over Load. ForMicroprocessor MCCBS Facility for segregating Priority andNon-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between frontcover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all thepoles simultaneously and they shall have a single mechanism. 200 A 35 kA | Each | 25121.02 | 25121.02 | 4.0 | False | None | None | False | None | False | 100484.08 | 0 | 3228702 | 111341 | None | P-12 I-5.14.11 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short- icrcuit/Over Load. ForMicroprocessor MCCBS Facility for segregating Priority andNon-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between frontcover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all thepoles simultaneously and they shall have a single mechanism. 250 A 35 kA | Each | 26585.4 | 26585.4 | 6.0 | False | None | None | False | None | False | 159512.4 | 0 | 3228703 | 111341 | None | P-12 I-5.14.12 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short- icrcuit/Over Load. ForMicroprocessor MCCBS Facility for segregating Priority andNon-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between frontcover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all thepoles simultaneously and they shall have a single mechanism. 320-400 A 50 kA | Each | 34328.56 | 34328.56 | 12.0 | False | None | None | False | None | False | 411942.72 | 0 | 3228704 | 111341 | None | P-12 I-5.14.15 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short- icrcuit/Over Load. ForMicroprocessor MCCBS Facility for segregating Priority andNon-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between frontcover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all thepoles simultaneously and they shall have a single mechanism. 700-800 A 50 kA | Each | 51358.32 | 51358.32 | 4.0 | False | None | None | False | None | False | 205433.28 | 0 | 3228705 | 111341 | None | P-12 I-5.15 | Supplying and fixing of Shunt trip suitable for MCCB.CBCT (12/5.15) | Each | 1784.16 | 1784.16 | 25.0 | False | None | None | False | None | False | 44604.0 | 0 | 3228706 | 111341 | None | P-14 I-5.21 | Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board. | Each | 9812.88 | 9812.88 | 13.0 | False | None | None | False | None | False | 127567.44 | 0 | 3228707 | 111341 | None | P-14 I-5.34 | Supplying, fixing and wiring 50/5 to 400/5Amps 5VA burden Current Transformer Class 0.5 accuracy with Tape Wound. | Each | 595.9 | 595.9 | 24.0 | False | None | None | False | None | False | 14301.6 | 0 | 3228708 | 111341 | None | P-14 I-5.38 | Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz 12/24V D.C. | Each | 547.52 | 547.52 | 21.0 | False | None | None | False | None | False | 11497.92 | 0 | 3228709 | 111341 | None | P-14 I-5.35 | Supplying, fixing and wiring Electronic Trivector Meter (ETV) 5 to 32/63 Amps three phase 4 wire whole current class-1 Accuracy Energy Meter.. | Each | 6047.5 | 6047.5 | 1.0 | False | None | None | False | None | False | 6047.5 | 0 | 3228710 | 111341 | None | P-11 I-5.12.5 | Supplying of on load change over switches 4 poles, AC- 23A Duty, 415V, 50Hz, AC Supply. With all accessories. (SM Enclosure Sheet Metal Execution) 800 A | Each | 64359.56 | 64359.56 | 1.0 | False | None | None | False | None | False | 64359.56 | 0 | 3228711 | 111341 | None | P-11 I-5.12.8 | Supplying of on load change over switches 4 poles, AC- 23A Duty, 415V, 50Hz, AC Supply. With all accessories. (SM Enclosure Sheet Metal Execution) 400 A | Each | 35669.04 | 35669.04 | 2.0 | False | None | None | False | None | False | 71338.08 | 0 | 3228712 | 111341 | None | P-11 I-5.12.5 | Supplying of on load change over switches 4 poles, AC- 23A Duty, 415V, 50Hz, AC Supply. With all accessories. (SM Enclosure Sheet Metal Execution) 200 A | Each | 14261.48 | 14261.48 | 1.0 | False | None | None | False | None | False | 14261.48 | 0 | 3228713 | 111341 | None | P-14 I-5.33 | Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH, KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy | Each | 9876.6 | 9876.6 | 12.0 | False | None | None | False | None | False | 118519.2 | 0 | 3228714 | 111341 | None | P-13 I-5.17.1 | Supplying & fixing miniature circuit breakers on existingMCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.6-32 A SP | Each | 617.14 | 617.14 | 6.0 | False | None | None | False | None | False | 3702.84 | 0 | 3228715 | 111341 | None | P-13 I-5.17.4 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' cure, indicator ON/OFF, energy cross-3 with Short circuit breaking cappacity of 10K and complete wiring as required. Confirming to IEC 60898. 6-32 Amps DP | Each | 1301.54 | 1301.54 | 168.0 | False | None | None | False | None | False | 218658.72 | 0 | 3228716 | 111341 | None | P-13 I-5.17.9 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' cure, indicator ON/OFF, energy cross-3 with Short circuit breaking cappacity of 10K and complete wiring as required. Confirming to IEC 60898. 50-63 Amps TPN | Each | 2830.82 | 2830.82 | 92.0 | False | None | None | False | None | False | 260435.44 | 0 | 3228717 | 111341 | None | P-15 I-5.42.2 | Fabricating supplying and mounting MS box made out …SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete14 SWG | Sq CM | 0.51 | 0.51 | 790000.0 | False | None | None | False | None | False | 402900.0 | 0 | 3228718 | 111341 | None | P-15 I-5.40.1 | Supplying ......... amps rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete.100 A 4 x 30 x 6 mm Aluminium Strips | m | 2612.52 | 2612.52 | 50.0 | False | None | None | False | None | False | 130626.0 | 0 | 3228719 | 111341 | None | P-15 I-5.40.2 | Supplying ......... amps rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 250 A 4 x 30 x 10 mm Aluminium Strips | m | 3632.04 | 3632.04 | 25.0 | False | None | None | False | None | False | 90801.0 | 0 | 3228720 | 111341 | None | P-15 I-5.40.3 | Supplying ......... amps rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 400 A 4 x 50 x 10 mm Aluminium Strips | m | 4715.28 | 4715.28 | 25.0 | False | None | None | False | None | False | 117882.0 | 0 | 3228721 | 111341 | None | P-15 I-5.41.5 | Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. 75 x 150 x 75 x 6 mm C channel | m | 981.76 | 981.76 | 10.0 | False | None | None | False | None | False | 9817.6 | 0 | 3228722 | 111341 | None | P-15 I-5.41.2 | Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. 50x50x6mm | m | 420.08 | 420.08 | 145.0 | False | None | None | False | None | False | 60911.6 | 0 | 3228723 | 111341 | None | P-15 I-5.41.3 | Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. 75 x 75 x 6 mm | m | 586.46 | 586.46 | 30.0 | False | None | None | False | None | False | 17593.8 | 0 | 3228724 | 111341 | None | P-3 I-2.3.4 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments . 4 mm2 | m | 69.62 | 69.62 | 200.0 | False | None | None | False | None | False | 13924.0 | 0 | 3228725 | 111341 | None | P-3 I-2.3.5 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments . 6mm2 | m | 102.66 | 102.66 | 250.0 | False | None | None | False | None | False | 25665.0 | 0 | 3228726 | 111341 | None | P-3 I-2.3.6 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments . 10 mm2 | m | 185.26 | 185.26 | 150.0 | False | None | None | False | None | False | 27789.0 | 0 | 3228727 | 111341 | None | P-3 I-2.3.7 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments . 16 mm2 | m | 375.24 | 375.24 | 100.0 | False | None | None | False | None | False | 37524.0 | 0 | 3228728 | 111341 | None | BESCOM P.No 16 P-410 I-49.05 | GI Pipe B - Class as per IS-1239 GI Pipe - 50 mm Dia | m | 451.94 | 451.94 | 50.0 | False | None | None | False | None | False | 22597.0 | 0 | 3228729 | 111341 | None | BESCOM P.No 16 P-411 I-49.05 | GI Pipe B - Class as per IS-1239 GI Pipe - 63 mm Dia | m | 489.7 | 489.7 | 50.0 | False | None | None | False | None | False | 24485.0 | 0 | 3228730 | 111341 | None | BESCOM P.No 16 P-411 I-49.05 | GI Pipe B - Class as per IS-1239 GI Pipe - 100 mm Dia | m | 1803.04 | 1803.04 | 120.0 | False | None | None | False | None | False | 216364.8 | 0 | 3228731 | 111341 | None | 25 P-688 I-70.01 | Brass Cable Gland 25 mm | No | 90.86 | 90.86 | 80.0 | False | None | None | False | None | False | 7268.8 | 0 | 3228732 | 111341 | None | 25 P-689 I-70.02 | Brass Cable Gland 32 mm | No | 109.74 | 109.74 | 80.0 | False | None | None | False | None | False | 8779.2 | 0 | 3228733 | 111341 | None | 25 P-689 I-70.03 | Brass Cable Gland 40 mm | No | 169.92 | 169.92 | 80.0 | False | None | None | False | None | False | 13593.6 | 0 | 3228734 | 111341 | None | 25 P-689 I-70.04 | Brass Cable Gland 45 mm | No | 226.56 | 226.56 | 30.0 | False | None | None | False | None | False | 6796.8 | 0 | 3228735 | 111341 | None | BESCOM P.No 9 P-215 I-32.05 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part- 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 16 Sqmm, 4 Core, (11 GI Strips - 4 x 0.8 mm) | Km | 216461.56 | 216461.56 | 0.35 | False | None | None | False | None | False | 75761.546 | 0 | 3228736 | 111341 | None | BESCOM P.No 9 P-215 I-32.07 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part- 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 . 25 Sqmm, 3.5 Core, (12 GI Strips - 4 x 0.8 mm | Km | 214113.36 | 214113.36 | 0.3 | False | None | None | False | None | False | 64234.008 | 0 | 3228737 | 111341 | None | BESCOM P.No 9 P-215 I-32.11 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part- 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 50 Sqmm, 3.5 Core, (16 GI Strips - 4 x 0.8 mm) | Km | 286044.98 | 286044.98 | 0.2 | False | None | None | False | None | False | 57208.996 | 0 | 3228738 | 111341 | None | BESCOM P.No 9 P-215 I-32.14 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part- 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 95 Sqmm, 3.5 Core, (21 GI Strips - 4 x 0.8 mm) | Km | 606567.2 | 606567.2 | 0.5 | False | None | None | False | None | False | 303283.6 | 0 | 3228739 | 111341 | None | BESCOM P.No 9 P-215 I-32.15 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part- 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 120 Sqmm, 3.5 Core, (23 GI Strips - 4 x 0.8 mm) | Km | 746716.98 | 746716.98 | 0.3 | False | None | None | False | None | False | 224015.094 | 0 | 3228740 | 111341 | None | BESCOM P.No 9 P-215 I-32.16 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part- 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 150 Sqmm, 3.5 Core, (25 GI Strips - 4 x 0.8 mm) | Km | 902347.18 | 902347.18 | 0.3 | False | None | None | False | None | False | 270704.154 | 0 | 3228741 | 111341 | None | BESCOM P.No 9 P-215 I-32.17 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part- 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 185 Sqmm, 3.5 Core, (28 GI Strips - 4 x 0.8 mm) | Km | 1121938.1 | 1121938.1 | 0.4 | False | None | None | False | None | False | 448775.24 | 0 | 3228742 | 111341 | None | BESCOM P.No 9 P-215 I-32.19 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part- 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 300 Sqmm, 3.5 Core, (32 GI Strips - 4 x 0.8 mm) | Km | 1752441.6 | 1752441.6 | 0.3 | False | None | None | False | None | False | 525732.48 | 0 | 3228743 | 111341 | None | BESCOM P.No 9 P-215 I-32.20 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part- 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 400 Sqmm, 3.5 Core, (39 GI Strips - 4 x 0.8 mm) | Km | 2315524.62 | 2315524.62 | 0.3 | False | None | None | False | None | False | 694657.386 | 0 | 3228744 | 111341 | None | 9 P-230 I-31.05 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff LT Cable 2.5 to 25 Sqmm | Km | 19067.62 | 19067.62 | 1.0 | False | None | None | False | None | False | 19067.62 | 0 | 3228745 | 111341 | None | 9 P-230 I-31.06 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff LT Cable 35 to 95 Sqmm | Km | 27903.46 | 27903.46 | 1.0 | False | None | None | False | None | False | 27903.46 | 0 | 3228746 | 111341 | None | 9 P-230 I-31.07 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff LT Cable 120 to 240 Sqmm | Km | 28494.64 | 28494.64 | 2.0 | False | None | None | False | None | False | 56989.28 | 0 | 3228747 | 111341 | None | 2014-15 P-63 I-7.20 b | Supply and laying double walled corrugated (DWC) HDPE Pipe including all necessary connecting Sockets/Couplings/Tees/Bends/End-caps of same materials in exisiting trench as per IS 14930 part -II suitable for drawing under ground cables. 50mm OD / 38mm ID | m | 178.18 | 178.18 | 1000.0 | False | None | None | False | None | False | 178180.0 | 0 | 3228748 | 111341 | None | 2014-15 P-63 I-7.20 d | Supply and laying double walled corrugated (DWC) HDPE Pipe including all necessary connecting Sockets/Couplings/Tees/Bends/End-caps of same materials in exisiting trench as per IS 14930 part -II suitable for drawing under ground cables. d) 77mm OD / 63mm ID | m | 307.98 | 307.98 | 900.0 | False | None | None | False | None | False | 277182.0 | 0 | 3228749 | 111341 | None | 2014-15 P-63 I-7.20 i | Supply and laying double walled corrugated (DWC) HDPE Pipe including all necessary connecting Sockets/Couplings/Tees/Bends/End-caps of same materials in exisiting trench as per IS 14930 part -II suitable for drawing under ground cables. i) 145mm OD / 123mm ID | m | 633.66 | 633.66 | 800.0 | False | None | None | False | None | False | 506928.0 | 0 | 3228750 | 111341 | None | 2014-15 P-63 I-7.20 m | Supply and laying double walled corrugated (DWC) HDPE Pipe including all necessary connecting Sockets/Couplings/Tees/Bends/End-caps of same materials in exisiting trench as per IS 14930 part -II suitable for drawing under ground cables. m) 200mm OD / 174mm ID | m | 860.22 | 860.22 | 800.0 | False | None | None | False | None | False | 688176.0 | 0 | 3228751 | 111341 | None | P-14 I-5.37 | Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 V grade, for power factor improvement of rotating machineries like induction motor | Kvar | 509.76 | 509.76 | 420.0 | False | None | None | False | None | False | 214099.2 | 0 | 3228752 | 111341 | None | P-15 I-5.39 | Supplying, fixing and wiring Automatic Power Factor controller circuit unit fully, static units controlled by 14 stage icroprocessor operation, relays LED display, self rogramming function for power stages and operating logic checking facility for healthy and efficient of each individual capacitor tank, measurement of network harmonics withindication when limit values are exceeded, Comprehensive displays with large, three phase LED display, Long term memory for settings, protection for over voltage, power factor correction fault and no voltage, to connect/ disconnect banks, with automatic recognition or with standard programs | Each | 22939.2 | 22939.2 | 3.0 | False | None | None | False | None | False | 68817.6 | 0 | 3228753 | 111341 | None | P-13 I-5.20.4 | Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker (ELMCB) 240/450V up to 300mA sensitivity on existing wood/panel board. 63 A 4 pole | Each | 3608.44 | 3608.44 | 10.0 | False | None | None | False | None | False | 36084.4 | 0 | 3228754 | 111341 | None | P-14 I-5.24 | Supplying, fixing and wiring 0 to 30A Direct Reading AC analog
type Ammeter | Each | 493.24 | 493.24 | 2.0 | False | None | None | False | None | False | 986.48 | 0 | 3228755 | 111341 | None | P-14 I-5.23 | Supplying, fixing and wiring 0 to 30V Direct Reading DC Voltmeter/Ammeter. | Each | 732.78 | 732.78 | 6.0 | False | None | None | False | None | False | 4396.68 | 0 | 3228756 | 111341 | None | P-12 I-5.13.2 | Supply and fixing of 4pole power contactor with NO/NC contacts on existing wood/panel board using necessary bolts, nuts, washers and wiring etc., complete with AC-3 Rating and as per IS-13947 40 A | Each | 2508.68 | 2508.68 | 30.0 | False | None | None | False | None | False | 75260.4 | 0 | 3228757 | 111341 | None | P-12 I-5.13.4 | Supply and fixing of 4pole power contactor with NO/NC contacts on existing wood/panel board using necessary bolts, nuts, washers and wiring etc., complete with AC-3 Rating and as per IS-13947 100 to 125 A | Each | 10621.18 | 10621.18 | 10.0 | False | None | None | False | None | False | 106211.8 | 0 | 3228758 | 111341 | None | 23 P-627 I-66.20 | Black Cambric tape 25 mm wide 10 mil thick and in rolls of 50 Mtr | Roll | 149.86 | 149.86 | 10.0 | False | None | None | False | None | False | 1498.6 | 0 |
|
|
---|