| 1717581745000 | 0 | None | None | Buildings | CONSTRUCTION OF SCRAP YARD AT MAIN DAIRY,GEJJALAGER. | 12904162.12 | | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
|---|
| 3231930 | 111583 | None | scrp01 | Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. By Manual Means In area of light jungle (PWD BC SR 2021-22, Vol -3 , Page 7, Item No 2.4A) | ha | 168300.0 | 168300.0 | 0.16 | False | None | None | False | None | False | 26928.0 | 0 | | 3231931 | 111583 | None | scrp02 | Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. (PWD BC SR 2021-22, Vol -1, Page 8, Item No 1.12) | Cum | 65.0 | 65.0 | 1890.0 | False | None | None | False | None | False | 122850.0 | 0 | | 3231932 | 111583 | None | scrp03 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work, In all kinds of soils Depth upto 3 m (PWD BC SR 2021-22, Vol -1 , Page 8, Item No 1.14) | Cum | 73.0 | 73.0 | 600.0 | False | None | None | False | None | False | 43800.0 | 0 | | 3231933 | 111583 | None | scrp04 | Earth work excavation for FOUNDATION by Mechanical means depth upto 1.50m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including cost of explosives, dressing of excavated surfaces, disposing off or levelling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, blasting materials, tools, usage of Machinery & all other appurtenaces required to complete the work In Hard Rock Depth exceeding 1.5 m, but not exceeding 3 m (PWD BC SR 2021-22, Vol -1 , Page 9, Item No 1.16.2) | Cum | 463.0 | 463.0 | 257.14 | False | None | None | False | None | False | 119055.82 | 0 | | 3231934 | 111583 | None | scrp05 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1-3-6 (M10) Using 40 mm nominal size graded crushed coarse aggregates.(PWD BC SR 2021-22, Page 163, Item No 19.7.1) (PWD BC SR 2021-22, Vol -1, Page 15, Item No 2.1.3) | Cum | 5554.0 | 5554.0 | 71.3 | False | None | None | False | None | False | 396000.2 | 0 | | 3231935 | 111583 | None | scrp06 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. (PWD SR 2021-22, Vol-1 . Page No. 14 . Item No. 1.10) | Cum | 122.0 | 122.0 | 857.14 | False | None | None | False | None | False | 104571.08 | 0 | | 3231936 | 111583 | None | scrp07 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1-3-6 (M10) Using 20 mm nominal size graded crushed coarse aggregates (PWD BC SR 2021-22, Page 163, Item No 19.7.1) (PWD BC SR 2021-22, Vol -1, Page 15, Item No 2.1.4) | Cum | 5728.0 | 5728.0 | 71.85 | False | None | None | False | None | False | 411556.8 | 0 | | 3231937 | 111583 | None | scrp08 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates as per the directions and instructions of engineer in charge. Complete with all lead and lift as per the instruction of the Engineer in incharge. (PWD BC SR 2021-22, Vol -1, Page 15, Item No 2.2.2.1) | Cum | 5979.0 | 5979.0 | 193.18 | False | None | None | False | None | False | 1155023.22 | 0 | | 3231938 | 111583 | None | scrp09 | Form Work For Footing ( 5% of Concrete Quantity) | Cum | 5979.0 | 5979.0 | 9.659 | False | None | None | False | None | False | 57751.161 | 0 | | 3231939 | 111583 | None | scrp10 | Providing and laying in position Reinforced cement concrete for all Sub structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - complete with all lead and lift as per the direction of Engineer-In-Charge Complete with all lead and lift as per the instruction of the Engineer in incharge. (PWD BC SR 2021-22, Vol -1, Page 17, Item No 2.4.3) | Cum | 5992.0 | 5992.0 | 229.88 | False | None | None | False | None | False | 1377440.96 | 0 | | 3231940 | 111583 | None | scrp11 | Form Work For columns ( 70% of Concrete Quantity) | Cum | 5992.0 | 5992.0 | 63.0 | False | None | None | False | None | False | 377496.0 | 0 | | 3231941 | 111583 | None | scrp12 | Form Work For plinth beams,lintel & chejja( 50 % of Concrete Quantity) | Cum | 5992.0 | 5992.0 | 14.625 | False | None | None | False | None | False | 87633.0 | 0 | | 3231942 | 111583 | None | scrp13 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates -Ground Floor Works complete with all lead and lift as per the direction of Engineer-In-Charge (PWD BC SR 2021-22, Vol -1, Page 17, Item No 2.4.3) | Cum | 6186.0 | 6186.0 | 39.45 | False | None | None | False | None | False | 244037.7 | 0 | | 3231943 | 111583 | None | scrp14 | Form Work For plinth beams,lintel & chejja( 60 % of Concrete Quantity) | Cum | 6186.0 | 6186.0 | 23.67 | False | None | None | False | None | False | 146422.62 | 0 | | 3231944 | 111583 | None | scrp15 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1-4 as per IS 2572-2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. (PWD BC SR 2021-22, Vol -2, Page 17, Item No 6.32) | Sqm | 1196.0 | 1196.0 | 228.0 | False | None | None | False | None | False | 272688.0 | 0 | | 3231945 | 111583 | None | scrp16 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix 1-3 (1 cement- 3 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (PWD BC SR 2021-22, Vol -2, Page 41, Item No 8.5.1) | Sqm | 311.0 | 311.0 | 812.4 | False | None | None | False | None | False | 252656.4 | 0 | | 3231946 | 111583 | None | scrp17 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1-5 (1 cement - 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1-3 (1 cement - 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as nper directions of Engineer-in-charge. (PWD BC SR 2021-22, Vol -2, Page 42, Item No 8.9) | Sqm | 322.0 | 322.0 | 812.4 | False | None | None | False | None | False | 261592.8 | 0 | | 3231947 | 111583 | None | scrp18 | Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) (PWD BC SR 2021-22, Vol -2, Page 84, Item No 11.32) | Kgs | 92.0 | 92.0 | 22795.18 | False | None | None | False | None | False | 2097156.56 | 0 | | 3231948 | 111583 | None | scrp19 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade -New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge( PWD SR 2018-19, Vol-2, page no 45, item no 8.25) | Sqm | 105.0 | 105.0 | 812.4 | False | None | None | False | None | False | 85302.0 | 0 | | 3231949 | 111583 | None | scrp20 | Finishing walls with Acrylic Smooth exterior paint of required shade -New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.( PWD SR 2018-19, Vol-2, page no 46, item no 8.30) | Sqm | 136.0 | 136.0 | 812.4 | False | None | None | False | None | False | 110486.4 | 0 | | 3231950 | 111583 | None | scrp21 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade -Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ( PWD SR 2021-22, Vol 2, page no 48, item no 8.41) | Sqm | 130.0 | 130.0 | 300.0 | False | None | None | False | None | False | 39000.0 | 0 | | 3231951 | 111583 | None | scrp22 | Providing and fixing to wall, ceiling and floor, low density polyethylene pipes 6.00 kgf/sq.cm working pressure 75mm outside diameter with special flange, compression type fittings, wall clips, making good the wall, ceiling and floor, including cost of all materials, labour charges, HOM of equipments and testing complete as per specifications. | Mtr | 1500.0 | 1500.0 | 80.0 | False | None | None | False | None | False | 120000.0 | 0 | | 3231952 | 111583 | None | scrp23 | Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS- 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ( PWD SR 2021-22 page no 76 item no 11.6.1) | Sqm | 2510.0 | 2510.0 | 60.0 | False | None | None | False | None | False | 150600.0 | 0 | | 3231953 | 111583 | None | scrp24 | Providing and fixing self supported ribbed high quality, high grcle (D-350 MPA Yst Min) prepainted Gal valume steel roof sheet with technical specification confirming to A 792 the sheet thickness not less than.1.30mm and coated by HOT dip process and bare Gal valume coating AZ 150, should be 150 gms/sqmtr (55% AL, 45% Zn) with tolerance of - 0/PLUS0.02 mm. The sheet should be in accordance with NCCA II-1, or ECCA T4 pencil.hardness HB, NCCA standard T-Bend test.. The roof should be fastened to the gutter beam, on the external sloping side, at an interval of 51mm c/c to a depth of 65mm with GI anchor bolts and neoprene washers. The gutter beam should be subjected to Schmidt, Hammer test to ensure the anchorage of the anchor bolts, the roofing system should be designed to with stand the wind load (As per IS 875Part-III) and Earth quake load (as per IS 1993) the design should also comply with any other requirements such as turbo ventilators and sky lights of polycarbonate sheet of area 2.60 sqm provided at 6mtrs c/c in a single row, as per the requirements including all lead and lift, loading and unloading, HOM of machineries as per standard detailed technical specifications, designand directionS of the Engineer in charge of the work (Quotation R-ate). ( PROFLEX) | Sqm | 3500.0 | 3500.0 | 1050.0 | False | None | None | False | None | False | 3675000.0 | 0 | | 3231954 | 111583 | None | scrp25 | Providing & fixing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete as per design drawings (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required as per the direction of Engineer in charge. 0.63 mm thick with zinc coating not less than 275 g/ m² ( PWD SR 2021-22 page no 21 item no 7.1.1) | Sqm | 795.0 | 795.0 | 156.0 | False | None | None | False | None | False | 124020.0 | 0 | | 3231955 | 111583 | None | scrp26 | Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ( PWD SR 2021-22, Vol 2, page no 82, item no 11.25.2) | Kgs | 108.0 | 108.0 | 1290.0 | False | None | None | False | None | False | 139320.0 | 0 | | 3231956 | 111583 | None | scrp27 | Supplying and fixing M.S. Rectangular poles made out of 2 equal angles of 65x65x6 mm welded together and fixed in CC (1-2-4) WITH 2 NOS 16mm dia M.S. hold fast rods each of length 25 cms. Including cost of all materials cutting, bending scaffolding wherever necessary, nicely finishing the welded joints with all lead lifts and as per the directions of the Engineer- in - charge of the work and including providing 2 coats of approved quality paint over one coat of shop painting (PWD BCSR 2018-19,P-266,I-37.2) | Mtr | 859.0 | 859.0 | 120.0 | False | None | None | False | None | False | 103080.0 | 0 | | 3231957 | 111583 | None | scrp28 | Providing and fixing M.S. Block pipe of 38mm dia, of heavy gauge of 14 including removing the bends, cutting the pipe, and fixing pipe in between the two vertical poles (M.S. rectangular poles) and spot welding the chain link with M.S. block pipe including cost of all materials wastage in cutting, and scaffolding wherever necessary with all lead and lift as directed by the Engineer-in-charge of work etc., complete including two coats of approved quality paint over one coat of shop paint (PWD BCSR 2018-19 P-266, I-37.4) . | Mtr | 408.0 | 408.0 | 320.0 | False | None | None | False | None | False | 130560.0 | 0 | | 3231958 | 111583 | None | scrp29 | Providing and fixing G.I. chain link fabric fencing of required width in mesh size 25x25 mm made of G.I. wire of dia 3 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge.(PWD BCSR 2021-22, Vol-2,P-95,I-11.6) | Sqm | 780.0 | 780.0 | 240.0 | False | None | None | False | None | False | 187200.0 | 0 | | 3231959 | 111583 | None | scrp30 | Earth work excavation for FOUNDATION by Mechanical means depth upto 1.50m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including cost of explosives, dressing of excavated surfaces, disposing off or levelling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, blasting materials, tools, usage of Machinery & all other appurtenaces required to complete the work Depth exceeding 3m, but not exceeding 4.5m (PWD SR 2021-22, Vol-1 . Page No. 62 . Item No. 1.18.3) | Cum | 540.0 | 540.0 | 81.6 | False | None | None | False | None | False | 44064.0 | 0 | | 3231960 | 111583 | None | scrp31 | Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. (PWD SR 2021-22, Vol-1 . Page No. 63 . Item No. 1.20) | Cum | 120.0 | 120.0 | 163.2 | False | None | None | False | None | False | 19584.0 | 0 | | 3231961 | 111583 | None | scrp32 | Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1-2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets 1200mm dia Clause 1106. (PWD SR 2021-22, Vol-3 . Page No. 155 . Item No. 9.3) Concrete Ring - 4 feet diameter | Mtr | 8161.0 | 8161.0 | 8.0 | False | None | None | False | None | False | 65288.0 | 0 | | 3231962 | 111583 | None | scrp33 | KSRB 7.9 - Providing and fixing M.S.grill work for windows and ventilators using M.S. flats, or 12mm M.S. square rods, or combination of M.S. flats and 12mm square rods as per approved design, drawing including cutting steel sections and welding the same to required pattern with a coat of red lead primer, cost of materials, fixtures, labour and HOM of machinery complete as per specifications. Specification No. KBS 7.12 (P W D SZSR , P-34, I-7.9) | Kgs | 120.0 | 120.0 | 45.76 | False | None | None | False | None | False | 5491.2 | 0 | | 3231963 | 111583 | None | scrp34 | KSRB 4.2.7 - Providing and laying in position reinforced cement concrete of design mix M25 with OPC cement @ 340kgs, with 20mm and down size graded granite metal coarse aggregates @0.70cum and fine aggregtes @ 0.47cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-2008, machine mixed, concrete laid in layers not exceeding 15 cms thick, vibrated for all works in ground floor level for roof slabs, staircase, lintles and beams retaining walls, return walls, walls (any thickness) including attached pilasters, columns, ,pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window cills, fillets etc., including cost of all materials, labour, HOM of machinery, curing, complete but including cost of reinforcement as per specifications.( Top Cover Slab is of Precasted Slab 15cm Thick ) (P NO 14 I NO 4.12)Top Pre Cast Slab ( 100MM Thick) | Cum | 5500.0 | 5500.0 | 2.04 | False | None | None | False | None | False | 11220.0 | 0 | | 3231964 | 111583 | None | scrp35 | Providing and Laying 40mm Granite Stone Aggregates arround the 1.20 m dia Concrete Ring up to 3.60 m height including cost of materials, labour complete spec. (P II I NO 25) | Sqm | 1050.0 | 1050.0 | 12.24 | False | None | None | False | None | False | 12852.0 | 0 | | 3231965 | 111583 | None | scrp36 | Demolishing brick tile covering in terracing including stacking of serviceablematerial and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge. | Cum | 52.0 | 52.0 | 81.6 | False | None | None | False | None | False | 4243.2 | 0 | | 3231966 | 111583 | None | scrp37 | Supplying heavy gauge PVC conduit pipe .dia…..mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc., and fixing using inverted wood plugs in case of RCC ceiling and RCC wall /stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. 19/20mm dia 2mm thick. PWD BCSR 2021-22 PG NO.1 IT NO. 1.1.1 | Mtr | 61.0 | 61.0 | 200.0 | False | None | None | False | None | False | 12200.0 | 0 | | 3231967 | 111583 | None | scrp38 | Supplying heavy gauge PVC conduit pipe ..dia ..mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc., and fixing using inverted wood plugs in case of RCC ceiling and RCC wall / stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. . 32mm dia 2.5mm thick PWD BESR 2021-22 PG NO.3 IT NO. 1.3.3 | Mtr | 105.0 | 105.0 | 130.0 | False | None | None | False | None | False | 13650.0 | 0 | | 3231968 | 111583 | None | scrp39 | Supplying heavy gauge PVC conduit pipe ..dia ..mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc., and fixing using inverted wood plugs in case of RCC ceiling and RCC wall / stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. . 32mm dia 2.5mm thick PWD BESR 2021-22 PG NO.3 IT NO. 1.3.3 | Mtr | 105.0 | 105.0 | 45.0 | False | None | None | False | None | False | 4725.0 | 0 | | 3231969 | 111583 | None | scrp40 | Supplying push button operated direct online starter with an antiweld silver cadmium oxide contactor with replaceable fixed and moving contacts and bimetallic thermal overload relay help in anticorrosion treated sheet or iron clad enclosure and fixing the same to suitable capacity wires for 400/440 volts 3 phase motor/single phase motor upto 5 HP. PWD BCSR 2021-22 PG NO.10 IT NO. 5.1 | Nos | 1490.0 | 1490.0 | 3.0 | False | None | None | False | None | False | 4470.0 | 0 | | 3231970 | 111583 | None | scrp41 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and C Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 5-32 Amps SP. PWD BCSR 2021-22 PG NO.13 IT NO. 5.17.1 | Nos | 523.0 | 523.0 | 10.0 | False | None | None | False | None | False | 5230.0 | 0 | | 3231971 | 111583 | None | scrp42 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and C Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 40 Amps SP. PWD BCSR 2021-22 PG NO.13 IT NO. 5.17.2 | Nos | 726.0 | 726.0 | 2.0 | False | None | None | False | None | False | 1452.0 | 0 | | 3231972 | 111583 | None | scrp43 | Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker (ELMCB) 240/450V up to 300mA sensitivity on existing wood/panel board.PWD BCSR 2021-22 PG NO.28 IT NO. 5.20.2 | Nos | 2652.0 | 2652.0 | 2.0 | False | None | None | False | None | False | 5304.0 | 0 | | 3231973 | 111583 | None | scrp44 | Supplying and fixing of Metal Socket set of 2pole and earth plugs and socket for incorporating SP and TP MCB (Without MCB ). The entire plug and socket shall be mounted in a thermoplastic / powder coated metal box & wired Completely. 20Amps PWD BCSR 2021-22 PG NO.16 IT NO. 5.45.2 | Nos | 873.0 | 873.0 | 6.0 | False | None | None | False | None | False | 5238.0 | 0 | | 3231974 | 111583 | None | scrp45 | Supplying and fixing of Metal Socket set of 2pole and earth plugs and socket for incorporating SP and TP MCB (Without MCB ). The entire plug and socket shall be mounted in a thermoplastic / powder coated metal box & wired Completely. 30Amps PWD BCSR 2021-22 PG NO.16 IT NO. 5.45.2 | Nos | 1534.0 | 1534.0 | 6.0 | False | None | None | False | None | False | 9204.0 | 0 | | 3231975 | 111583 | None | scrp46 | Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2x1.5 sqmm Cable confirming to the GTP without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet. Short point upto 3Mtr from tapping point to out let via switch box PWD BCSR 2021-22 PG NO.3 IT NO. 2.21 | Nos | 251.0 | 251.0 | 90.0 | False | None | None | False | None | False | 22590.0 | 0 | | 3231976 | 111583 | None | scrp47 | Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2x1.5 sqmm Cable confirming to the GTP without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet. Medium point above 3Mtr upto 6Mtr from tapping point to outlet via switch box PWD BESR 2019-20 PG NO.5 IT NO. 2.2.1 | Nos | 361.0 | 361.0 | 10.0 | False | None | None | False | None | False | 3610.0 | 0 | | 3231977 | 111583 | None | scrp48 | Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2x1.5 sqmm Cable confirming to the GTP without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet. Long point above 6Mtr upto 10Mtr from tapping point to outlet via switch box PWD BESR 2021-22 PG NO.3 IT NO. 2.2.2 | Nos | 542.0 | 542.0 | 10.0 | False | None | None | False | None | False | 5420.0 | 0 | | 3231978 | 111583 | None | scrp49 | Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2x1.5 sqmm Cable confirming to the GTP without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet.Two outlet in a rowThree above 6Mtr upto 10Mtr from tapping point to outlet via switchs box PWD BESR 2021-22 PG NO.3 IT NO. 2.1.2 | Nos | 671.0 | 671.0 | 50.0 | False | None | None | False | None | False | 33550.0 | 0 | | 3231979 | 111583 | None | scrp50 | Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2x1.5 sqmm Cable confirming to the GTP without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet.Two outlet in a rowThree above 6Mtr upto 10Mtr from tapping point to outlet via switchs box PWD BESR 2021-22 PG NO.3 IT NO. 2.1.3 | Nos | 671.0 | 671.0 | 10.0 | False | None | None | False | None | False | 6710.0 | 0 | | 3231980 | 111583 | None | scrp51 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694-confirming to latest amendments.4 sqmm PWD BESR 2021-22 PG NO.3 IT NO. 2.3.4 | Nos | 59.0 | 59.0 | 160.0 | False | None | None | False | None | False | 9440.0 | 0 | | 3231981 | 111583 | None | scrp52 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694-confirming to latest amendments. 6 sqmm PWD BESR 2021-22 PG NO.3 IT NO. 2.3.5 | Nos | 87.0 | 87.0 | 100.0 | False | None | None | False | None | False | 8700.0 | 0 | | 3231982 | 111583 | None | scrp53 | Supplying 6A flush type socket and 6 amps flush type SP switch either surface or flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3654 PWD BESR 2021-22 PG NO.5 IT NO. 3.1.1 | Nos | 121.0 | 121.0 | 160.0 | False | None | None | False | None | False | 19360.0 | 0 | | 3231983 | 111583 | None | scrp54 | Supplying and fixing/replacing of 6/16/32Amps electrical accessories on existing switch board. 16Combined switch and socket with indication. PWD BESR 2019-20 PG NO.6 IT NO. 3.14.14 | Nos | 281.0 | 281.0 | 20.0 | False | None | None | False | None | False | 5620.0 | 0 | | 3231984 | 111583 | None | scrp55 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 4-5 Way PWD BESR 2021-22 PG NO.5 IT NO. 3.4.2 | Nos | 138.0 | 138.0 | 12.0 | False | None | None | False | None | False | 1656.0 | 0 | | 3231985 | 111583 | None | scrp56 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 1 to 3 Module PWD BESR 2021-22 PG NO.5 IT NO. 3.5.1 | Nos | 152.0 | 152.0 | 12.0 | False | None | None | False | None | False | 1824.0 | 0 | | 3231986 | 111583 | None | scrp57 | Supplying and fixing of modular switch/socket/stepped electronic fan regulator or dimmer or telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 16Amps one way switch | Nos | 249.0 | 249.0 | 12.0 | False | None | None | False | None | False | 2988.0 | 0 | | 3231987 | 111583 | None | scrp58 | Supplying and fixing of modular switch/socket/stepped electronic fan regulator or dimmer or telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 RJ45/ I.O. outlet | Nos | 211.0 | 211.0 | 12.0 | False | None | None | False | None | False | 2532.0 | 0 | | 3231988 | 111583 | None | scrp59 | Supplying and fixing of metal clad industrial plugs and sockets 2polePLUSearth 250V | Nos | 220.0 | 220.0 | 10.0 | False | None | None | False | None | False | 2200.0 | 0 | | 3231989 | 111583 | None | scrp60 | Supplying and fixing of metal clad industrial plugs and sockets 3polePLUSearth 440V | Nos | 280.0 | 280.0 | 12.0 | False | None | None | False | None | False | 3360.0 | 0 | | 3231990 | 111583 | None | scrp61 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x3mm GI | Nos | 75.0 | 75.0 | 50.0 | False | None | None | False | None | False | 3750.0 | 0 | | 3231991 | 111583 | None | scrp62 | Supplying of .feet - PVC Batten with integrated LED tube W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI greter than 80. Power Input- 220-240V @ 50/60Hz & Power factor greter than0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.(MIRROR LIGHT) PWD BCSR 2021-22 PG NO.34 IT NO. 11.3.3 | Nos | 1197.0 | 1197.0 | 80.0 | False | None | None | False | None | False | 95760.0 | 0 | | 3231992 | 111583 | None | scrp63 | Supply of LED pole mounting type post top lantern with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/ clear glass material, delivering superior light output.Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, CCT greter than 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire greter than IK08. Power Factor greter than0.9 with mains, Surge Protection- Min 5KV along with Over voltage/Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB . LED Efficiencygreter than130lm/w, nominal CRI greter than75. Luminaire manufacturer should have inhouse facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001-2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/umileds/Osram make LED Source. LED Post Top Lantern with 35 watts PWD BCSR 2021-22 PG NO.35 IT NO. 11.7.2 | Nos | 7912.0 | 7912.0 | 4.0 | False | None | None | False | None | False | 31648.0 | 0 |
|