createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1717588639346
version2
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeONE_COVER
evaluationTypeTextOne Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee500.00
emd10407.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose19-06-2024 17:30:00
tenderQueryClose18-06-2024 17:30:00
technicalBidOpenNone
publishedDate05-06-2024 17:44:49
publishedByPostCMC_MCOM_YDG
publishedByUserKPE17311 - LAXMIKANTH
bidValidityPeriod90
noOfCalls1
preBidMeetingDateNone
preBidMeetingYnFalse
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonSECTION OFFICER
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedNone
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumberNone
mobileNumber8762178772
tenderSupplierListNone
tenderSchedule
createdTs1717588639381
version4
createdDateNone
modifiedDateNone
tenderNumberDMA/2024-25/OW/WORK_INDENT18348
titleSINKING OF BOREWELL, ELECTRIFICTION, INSTALLATION OF CC CAMERA, TOKEN DISPENSER MACHINE, CONSTRUCTION OF ARCH TO MAIN GATE, REPAIRS AND PAINTING TO INDIRA CANTEEN IN YADGIR CMC LIMITS
descriptionSINKING OF BOREWELL, ELECTRIFICTION, INSTALLATION OF CC CAMERA, TOKEN DISPENSER MACHINE, CONSTRUCTION OF ARCH TO MAIN GATE, REPAIRS AND PAINTING TO INDIRA CANTEEN IN YADGIR CMC LIMITS
categoryWORKS
categoryTextWorks
ecv416312.59
deptNameDirectorate of Municipal Administration
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnTrue
location2430
locationNameDMA City Municipal Council Yadagiri
provisionalAmount500000.0
groupOverheadTotalNone
fileNumber2024-25/1
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17175886390000NoneNoneOther WorksSINKING OF BOREWELL, ELECTRIFICTION, INSTALLATION OF CC CAMERA, TOKEN DISPENSER MACHINE, CONSTRUCTION OF ARCH TO MAIN GATE, REPAIRS AND PAINTING TO INDIRA CANTEEN IN YADGIR CMC LIMITS416312.59
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3232356111655Nonecode01Geophysical investigation at site for sinking borewells for Providing drinking water to the habitation either through the Hand Pump MWS or P.W.S.S, by vertical electrical sounding by adopting Venner or Schlumbergers's method, including reconnaissance survey of geological formation. Geophysical investigation of existing ground water in the vicinity, its quality, quantity and acceptability of the users, indicating the location of the site, recommended depth of casing pipe required to seal the top unconsolidated formation including an extra depth of 1.0 metre in consolidated formation for proper seating of casing pipe, depth of drilling required to cover full depth of aquifer proposed to be tapped, probable yield and other information required including transportation of instruments and accessories to work site, engaging technical personal and labour required etc. NOTE: 1) Additional rate on item 1&2 is allowed for drilling in over burden and fixing Casing pipes beyond 20 M (for fixing Casing pipes only) a) Above 20 M and upto 30 M - 15%, b) Above 30 M - 30% (Measurement of overburden is restricted to the depth of casing pipe fixed excluding initial depth of 20M and projection above ground level). 2) A sum of Rs. 100/- is to be deducted for Dry Borewell towards yield test. etc. completeEach5552.45552.41.0FalseNoneNoneFalseNoneFalse5552.40
3232357111655Nonecode02Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) Borewell depth of 0 to 50 Mtrsm388.5388.550.0FalseNoneNoneFalseNoneFalse19425.00
3232358111655Nonecode03Borewell depth of 50 to 100 Mtrsm487.2487.250.0FalseNoneNoneFalseNoneFalse24360.00
3232359111655Nonecode04Supply of PVC pipes of 10 Kg/cm2 for 160mmm756.0756.024.0FalseNoneNoneFalseNoneFalse18144.00
3232360111655Nonecode05Providing and laying at site of work MS casing caps as per IS 1239 (part- II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments including cost of material and labour charges for fixing, if any etc. complete with all lead and lifts and as directed by the Engineer in chargeEach172.2172.21.0FalseNoneNoneFalseNoneFalse172.20
3232361111655Nonecode06Providing, Single Phase Submersible Pump Sets of 100mm dia (4 inch) suitable for bore well confirming to IS 8034-2000 specifications, to work site with testing of as per instructions of engineer incharge of work and latest amendments etc. complete..1.00 HP/0.75KW 18 STGNo16464.016464.01.0FalseNoneNoneFalseNoneFalse16464.00
3232362111655Nonecode07Supply and delivery at site Brand new best make PVC insulated cable of Flat 3 core (sheathed) of nominal cross sectional area as per IS 694-1990 with ISI Mark and as per its latest amendments..1x3x4 m2m141.75141.7575.0FalseNoneNoneFalseNoneFalse10631.250
3232363111655Nonecode08Labour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all items including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges,tools and equipments etc., involved in the job as per specifications, with necessary tests as per specifications, with testing of as per instructions of engineer incharge of work.Job6825.06825.01.0FalseNoneNoneFalseNoneFalse6825.00
3232364111655Nonecode09Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOL- Direct Online Starter 2) S-D- Star Delta Starter etc. complete.for outdoor Upto 3 HP pumpsNo7875.07875.01.0FalseNoneNoneFalseNoneFalse7875.00
3232365111655Nonecode10Labour charges for erection of outdoor type panel board and meter board units with all necessary materials and labour, tools and equipments including providing cement concrete foundation bed etc., complete as per specification, with testing of as per instructions of engineer incharge of work.Job1522.51522.51.0FalseNoneNoneFalseNoneFalse1522.50
3232366111655Nonecode11Providing main connection from pole PVC insulated sheathed steel wire cable in new trench as per IS 1554/ 1988 with latest amendments with ISI mark from KPTCL pole to meter board unit.m141.75141.7515.0FalseNoneNoneFalseNoneFalse2126.250
3232367111655Nonecode1232mm Normal gauge polythene bore pipesm74.5574.5570.0FalseNoneNoneFalseNoneFalse5218.50
3232368111655Nonecode13Supply and delivery at site of brand new best make non-return valve as per IS 778/1984 with ISI Mark and as per its latest amendments Size 50 mmNo1312.51312.51.0FalseNoneNoneFalseNoneFalse1312.50
3232369111655Nonecode14Supply and delivery at site of brand new best make gate valve as per IS 778/1984 with ISI Mark and as per its latest amendments 50mmNo1312.51312.51.0FalseNoneNoneFalseNoneFalse1312.50
3232370111655Nonecode15Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 25 mm nominal dia Pipesm333.9333.990.0FalseNoneNoneFalseNoneFalse30051.00
3232371111655Nonecode16Providing and erecting overhead signs with a corrosion resistant 2mm thick aluminium alloy sheet reflectorised with high intensity retro-reflective sheeting as per IRC:67:2022 with vertical and lateral clearance given in clause 802.2 and 802.3 and installed as per clause 802.7 over a designed support system of aluminium alloy or galvanised steel trestles and trusses of sections and type as per structural design requirements and approved plans.Truss and Vertical SupportTonne90853.3590853.350.229FalseNoneNoneFalseNoneFalse20805.417150
3232372111655Nonecode17Providing and erecting overhead signs with a corrosion resistant 2mm thick aluminium alloy sheet reflectorised with high intensity retro-reflective sheeting as per IRC:67:2022 with vertical and lateral clearance given in clause 802.2 and 802.3 and installed as per clause 802.7 over a designed support system of aluminium alloy or galvanised steel trestles and trusses of sections and type as per structural design requirements and approved plans. Aluminium Alloy Plate for Over Head SignSqm6108.96108.94.32FalseNoneNoneFalseNoneFalse26390.4480
3232373111655Nonecode18Providing and fixing of Aluminium composite panel of approved make and colour for wall cladding for Brick/Rcc/stone walls & coloumns/beams with necessary aluminium frame works at required level made out of 50x25x4mm C section or equivalent. The panel should consist of 3mm thick non-halogenated FR grade mineral based polymer ( 2 hrs fire resistance as per ASTM E119-12 and clause B, S1, do as per ENT 13501-1sandwiched between 0.50 skins thick aluminium sheet making a total panel thickness of 4mm. The surfaces will be finished with PVDF based coating on topsides and service coating on reverse sides would be in polyester paint. The system shall be fixed using GI brackets, aluminium L cleats and stainless steel bolts and nuts complete with spring washer and cap nuts and all other necessary accessories, sealing shall be done with necessary rods etc., complete For Straight PortionSqm4188.454188.458.94FalseNoneNoneFalseNoneFalse37444.7430
3232374111655Nonecode19Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 L/10 m² over and including one coat of Special primer applied @ 0.75 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm165.9165.9123.2FalseNoneNoneFalseNoneFalse20438.880
3232375111655Nonecode20Finishing walls with water proofing cement paint of required shade :Old work (one coats applied @ 2.20 kg/10 m²) over priming coat of primer applied @ 0.80 l/10 m² complete including cost of Priming coat including preparing the surface after thoroughly cleaning the surface to remove all dirt, dust and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm91.3591.35120.0FalseNoneNoneFalseNoneFalse10962.00
3232376111655Nonecode21Supplying heavy gauge PVC conduit pipe 25mm dia 2 mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessarym53.053.060.0FalseNoneNoneFalseNoneFalse3180.00
3232377111655Nonecode22Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.5 sqmmm32.032.0180.0FalseNoneNoneFalseNoneFalse5760.00
3232378111655Nonecode23Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Three outlet in a row, above 6Mts upto 10Mtr from tapping point to out let via switchesPoint750.0750.05.0FalseNoneNoneFalseNoneFalse3750.00
3232379111655Nonecode24Supplying & Fixing of 230 Volts 20/40 watts Fluorescent Lamp holderNo15.015.020.0FalseNoneNoneFalseNoneFalse300.00
3232380111655Nonecode25Supplying & fixing retrofit type -PL- LED 18-20 Watts linear source with CCT 6500 degree K, CRI 70%. efficacy 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.18-20 WattsNo425.0425.020.0FalseNoneNoneFalseNoneFalse8500.00
3232381111655Nonecode26Supplying of 1440rpm heavy duty exhaust fan with bracket blades suitable to operate on 230V 50Hz, AC Supply complete. 12" Sweep (300 mm)No2969.02969.05.0FalseNoneNoneFalseNoneFalse14845.00
3232382111655Nonecode27TOKEN Dispenser MachineNo12000.012000.01.0FalseNoneNoneFalseNoneFalse12000.00
3232383111655Nonecode28DOME Camera CP Plus :3MP 360 Camera with Motion Detection, 2-Way Talk & Night Vision Security Camera (1 Channel) including Fixing ChargesNo4000.04000.06.0FalseNoneNoneFalseNoneFalse24000.00
3232384111655Nonecode29D-Link LAN Cable 90 m Alloy Brading CCTV cable 90 (Compatible with CCTV Camera, White, One Cable) including Fixing ChargesNo2500.02500.06.0FalseNoneNoneFalseNoneFalse15000.00
3232385111655Nonecode30Seagate Okoye SE FireCuda 2 TB External Hard Disk Drive fixing ChargesNo12000.012000.02.0FalseNoneNoneFalseNoneFalse24000.00
3232386111655Nonecode31Supply of LED floodlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/clear glass material, delivering superior light output Rated life Burning Hrs 50000 hr Lumen Maintenance of 70%, CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection Min 5KV along with Over voltag Overload, short circuit/ miss-wiring protection. Compatible for pole mauling with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100 V to 270V 50/60Hz application. Compliance to IS 10322/ IEC 60598, LM 79 LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ....... W System Power consumption. LED Efficienc 1301m/w, nominal CRI 75. Luminaire manufacturer should have in- house facility accredited by NABL / CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark / name shall be Engraved / Embossing on the die cast housing / Body part Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Floodlight 100WNo9486.09486.04.0FalseNoneNoneFalseNoneFalse37944.00
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17175886420000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17175886420000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17175886420000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17175886420000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17175886420000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
17175886420000NoneNoneELIGIBILITYDepartment Registration DetailsNone
17175886420000NoneNoneELIGIBILITYTotal value of civl engineering works executed and payments received in the last five years (year-wise)None
17175886420000NoneNoneELIGIBILITYList of existing commitments and ongoing workNone
17175886420000NoneNoneELIGIBILITYList of works for which tenders already submittedNone
17175886420000NoneNoneELIGIBILITYBanker DetailsNone
preQualCriterionListNone
technicalCriterionListNone
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
KPWD Civil Class IV & above licenseTrueTechnical Bid
Annual turnover certificate along with valid UDIN and ITRTrueTechnical Bid
Work done certificate as per tender documentTrueTechnical Bid
Bankers certificateTrueTechnical Bid
DD/FDR towards quoting less than ECVTrueTechnical Bid
GST Registration certificateTrueTechnical Bid
All other documents as per tender documentTrueTechnical Bid
tenderWorkLocationList
tenderAddressNone
tenderRecallDTONone