| 3232356 | 111655 | None | code01 | Geophysical investigation at site for sinking borewells for Providing drinking water to the habitation either through the Hand Pump MWS or P.W.S.S, by vertical electrical sounding by adopting Venner or Schlumbergers's method, including reconnaissance survey of geological formation. Geophysical investigation of existing ground water in the vicinity, its quality, quantity and acceptability of the users, indicating the location of the site, recommended depth of casing pipe required to seal the top unconsolidated formation including an extra depth of 1.0 metre in consolidated formation for proper seating of casing pipe, depth of drilling required to cover full depth of aquifer proposed to be tapped, probable yield and other information required including transportation of instruments and accessories to work site, engaging technical personal and labour required etc. NOTE: 1) Additional rate on item 1&2 is allowed for drilling in over burden and fixing Casing pipes beyond 20 M (for fixing Casing pipes only) a) Above 20 M and upto 30 M - 15%, b) Above 30 M - 30% (Measurement of overburden is restricted to the depth of casing pipe fixed excluding initial depth of 20M and projection above ground level). 2) A sum of Rs. 100/- is to be deducted for Dry Borewell towards yield test. etc. complete | Each | 5552.4 | 5552.4 | 1.0 | False | None | None | False | None | False | 5552.4 | 0 |
| 3232357 | 111655 | None | code02 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) Borewell depth of 0 to 50 Mtrs | m | 388.5 | 388.5 | 50.0 | False | None | None | False | None | False | 19425.0 | 0 |
| 3232358 | 111655 | None | code03 | Borewell depth of 50 to 100 Mtrs | m | 487.2 | 487.2 | 50.0 | False | None | None | False | None | False | 24360.0 | 0 |
| 3232359 | 111655 | None | code04 | Supply of PVC pipes of 10 Kg/cm2 for 160mm | m | 756.0 | 756.0 | 24.0 | False | None | None | False | None | False | 18144.0 | 0 |
| 3232360 | 111655 | None | code05 | Providing and laying at site of work MS casing caps as per IS 1239 (part- II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments including cost of material and labour charges for fixing, if any etc. complete with all lead and lifts and as directed by the Engineer in charge | Each | 172.2 | 172.2 | 1.0 | False | None | None | False | None | False | 172.2 | 0 |
| 3232361 | 111655 | None | code06 | Providing, Single Phase Submersible Pump Sets of 100mm dia (4 inch) suitable for bore well confirming to IS 8034-2000 specifications, to work site with testing of as per instructions of engineer incharge of work and latest amendments etc. complete..1.00 HP/0.75KW 18 STG | No | 16464.0 | 16464.0 | 1.0 | False | None | None | False | None | False | 16464.0 | 0 |
| 3232362 | 111655 | None | code07 | Supply and delivery at site Brand new best make PVC insulated cable of Flat 3 core (sheathed) of nominal cross sectional area as per IS 694-1990 with ISI Mark and as per its latest amendments..1x3x4 m2 | m | 141.75 | 141.75 | 75.0 | False | None | None | False | None | False | 10631.25 | 0 |
| 3232363 | 111655 | None | code08 | Labour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all items including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges,tools and equipments etc., involved in the job as per specifications, with necessary tests as per specifications, with testing of as per instructions of engineer incharge of work. | Job | 6825.0 | 6825.0 | 1.0 | False | None | None | False | None | False | 6825.0 | 0 |
| 3232364 | 111655 | None | code09 | Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOL- Direct Online Starter 2) S-D- Star Delta Starter etc. complete.for outdoor Upto 3 HP pumps | No | 7875.0 | 7875.0 | 1.0 | False | None | None | False | None | False | 7875.0 | 0 |
| 3232365 | 111655 | None | code10 | Labour charges for erection of outdoor type panel board and meter board units with all necessary materials and labour, tools and equipments including providing cement concrete foundation bed etc., complete as per specification, with testing of as per instructions of engineer incharge of work. | Job | 1522.5 | 1522.5 | 1.0 | False | None | None | False | None | False | 1522.5 | 0 |
| 3232366 | 111655 | None | code11 | Providing main connection from pole PVC insulated sheathed steel wire cable in new trench as per IS 1554/ 1988 with latest amendments with ISI mark from KPTCL pole to meter board unit. | m | 141.75 | 141.75 | 15.0 | False | None | None | False | None | False | 2126.25 | 0 |
| 3232367 | 111655 | None | code12 | 32mm Normal gauge polythene bore pipes | m | 74.55 | 74.55 | 70.0 | False | None | None | False | None | False | 5218.5 | 0 |
| 3232368 | 111655 | None | code13 | Supply and delivery at site of brand new best make non-return valve as per IS 778/1984 with ISI Mark and as per its latest amendments Size 50 mm | No | 1312.5 | 1312.5 | 1.0 | False | None | None | False | None | False | 1312.5 | 0 |
| 3232369 | 111655 | None | code14 | Supply and delivery at site of brand new best make gate valve as per IS 778/1984 with ISI Mark and as per its latest amendments 50mm | No | 1312.5 | 1312.5 | 1.0 | False | None | None | False | None | False | 1312.5 | 0 |
| 3232370 | 111655 | None | code15 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 25 mm nominal dia Pipes | m | 333.9 | 333.9 | 90.0 | False | None | None | False | None | False | 30051.0 | 0 |
| 3232371 | 111655 | None | code16 | Providing and erecting overhead signs with a corrosion resistant 2mm thick aluminium alloy sheet reflectorised with high intensity retro-reflective sheeting as per IRC:67:2022 with vertical and lateral clearance given in clause 802.2 and 802.3 and installed as per clause 802.7 over a designed support system of aluminium alloy or galvanised steel trestles and trusses of sections and type as per structural design requirements and approved plans.Truss and Vertical Support | Tonne | 90853.35 | 90853.35 | 0.229 | False | None | None | False | None | False | 20805.41715 | 0 |
| 3232372 | 111655 | None | code17 | Providing and erecting overhead signs with a corrosion resistant 2mm thick aluminium alloy sheet reflectorised with high intensity retro-reflective sheeting as per IRC:67:2022 with vertical and lateral clearance given in clause 802.2 and 802.3 and installed as per clause 802.7 over a designed support system of aluminium alloy or galvanised steel trestles and trusses of sections and type as per structural design requirements and approved plans. Aluminium Alloy Plate for Over Head Sign | Sqm | 6108.9 | 6108.9 | 4.32 | False | None | None | False | None | False | 26390.448 | 0 |
| 3232373 | 111655 | None | code18 | Providing and fixing of Aluminium composite panel of approved make and colour for wall cladding for Brick/Rcc/stone walls & coloumns/beams with necessary aluminium frame works at required level made out of 50x25x4mm C section or equivalent. The panel should consist of 3mm thick non-halogenated FR grade mineral based polymer ( 2 hrs fire resistance as per ASTM E119-12 and clause B, S1, do as per ENT 13501-1sandwiched between 0.50 skins thick aluminium sheet making a total panel thickness of 4mm. The surfaces will be finished with PVDF based coating on topsides and service coating on reverse sides would be in polyester paint. The system shall be fixed using GI brackets, aluminium L cleats and
stainless steel bolts and nuts complete with spring washer and cap nuts and all other necessary accessories, sealing shall be done with necessary rods etc., complete For Straight Portion | Sqm | 4188.45 | 4188.45 | 8.94 | False | None | None | False | None | False | 37444.743 | 0 |
| 3232374 | 111655 | None | code19 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 L/10 m² over and including one coat of Special primer applied @ 0.75 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 165.9 | 165.9 | 123.2 | False | None | None | False | None | False | 20438.88 | 0 |
| 3232375 | 111655 | None | code20 | Finishing walls with water proofing cement paint of required shade :Old work (one coats applied @ 2.20 kg/10 m²) over priming coat of primer applied @ 0.80 l/10 m² complete including cost of Priming coat
including preparing the surface after thoroughly cleaning the surface to remove all dirt, dust and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 91.35 | 91.35 | 120.0 | False | None | None | False | None | False | 10962.0 | 0 |
| 3232376 | 111655 | None | code21 | Supplying heavy gauge PVC conduit pipe 25mm dia 2 mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary | m | 53.0 | 53.0 | 60.0 | False | None | None | False | None | False | 3180.0 | 0 |
| 3232377 | 111655 | None | code22 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.5 sqmm | m | 32.0 | 32.0 | 180.0 | False | None | None | False | None | False | 5760.0 | 0 |
| 3232378 | 111655 | None | code23 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Three outlet in a row, above 6Mts upto 10Mtr from tapping point to out let via switches | Point | 750.0 | 750.0 | 5.0 | False | None | None | False | None | False | 3750.0 | 0 |
| 3232379 | 111655 | None | code24 | Supplying & Fixing of 230 Volts 20/40 watts Fluorescent Lamp holder | No | 15.0 | 15.0 | 20.0 | False | None | None | False | None | False | 300.0 | 0 |
| 3232380 | 111655 | None | code25 | Supplying & fixing retrofit type -PL- LED 18-20 Watts linear source with CCT 6500 degree K, CRI 70%. efficacy 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.18-20 Watts | No | 425.0 | 425.0 | 20.0 | False | None | None | False | None | False | 8500.0 | 0 |
| 3232381 | 111655 | None | code26 | Supplying of 1440rpm heavy duty exhaust fan with bracket blades suitable to operate on 230V 50Hz, AC Supply complete. 12" Sweep (300 mm) | No | 2969.0 | 2969.0 | 5.0 | False | None | None | False | None | False | 14845.0 | 0 |
| 3232382 | 111655 | None | code27 | TOKEN Dispenser Machine | No | 12000.0 | 12000.0 | 1.0 | False | None | None | False | None | False | 12000.0 | 0 |
| 3232383 | 111655 | None | code28 | DOME Camera CP Plus :3MP 360 Camera with Motion Detection, 2-Way Talk & Night Vision Security Camera (1 Channel) including Fixing Charges | No | 4000.0 | 4000.0 | 6.0 | False | None | None | False | None | False | 24000.0 | 0 |
| 3232384 | 111655 | None | code29 | D-Link LAN Cable 90 m Alloy Brading CCTV cable 90 (Compatible with CCTV Camera, White, One Cable) including Fixing Charges | No | 2500.0 | 2500.0 | 6.0 | False | None | None | False | None | False | 15000.0 | 0 |
| 3232385 | 111655 | None | code30 | Seagate Okoye SE FireCuda 2 TB External Hard Disk Drive fixing Charges | No | 12000.0 | 12000.0 | 2.0 | False | None | None | False | None | False | 24000.0 | 0 |
| 3232386 | 111655 | None | code31 | Supply of LED floodlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/clear glass material, delivering superior light output Rated life Burning Hrs 50000 hr Lumen Maintenance of 70%, CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection Min 5KV along with Over voltag Overload, short circuit/ miss-wiring protection. Compatible for pole mauling with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100 V to 270V 50/60Hz application. Compliance to IS 10322/ IEC 60598, LM 79 LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ....... W System Power consumption. LED Efficienc 1301m/w, nominal CRI 75. Luminaire manufacturer should have in- house facility accredited by NABL / CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark / name shall be Engraved / Embossing on the die cast housing / Body part Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Floodlight 100W | No | 9486.0 | 9486.0 | 4.0 | False | None | None | False | None | False | 37944.0 | 0 |