createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1717396936909
version5
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee550.00
emd44000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose14-06-2024 16:00:00
tenderQueryClose11-06-2024 11:00:00
technicalBidOpen15-06-2024 16:30:00
publishedDate07-06-2024 11:48:16
publishedByPostPWD_EE_ELEDIV_BNG
publishedByUserKPE14457 - H P RAJESH
bidValidityPeriod90
noOfCalls1
preBidMeetingDateNone
preBidMeetingYnFalse
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonBaramappa
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumberNone
mobileNumber9900114538
tenderSupplierListNone
tenderSchedule
createdTs1717396936947
version9
createdDateNone
modifiedDateNone
tenderNumberPWD/2024-25/EL/WORK_INDENT10910
titleProviding Electrification under the main Estimate of Construction of BEO Office at Hiriyuru Twon Chitradurga Dist.
descriptionProviding Electrification under the main Estimate of Construction of BEO Office at Hiriyuru Twon Chitradurga Dist.
categoryWORKS
categoryTextWorks
ecv2176978.60
deptNamePublic Works Department
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnFalse
location1665
locationNamePWD Electrical Division Office Bengaluru
provisionalAmount2600000.0
groupOverheadTotal0.0
fileNumberKPWD/ELE/2024-25
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17173969370000NoneNoneElectricalPart A Internal wiring to BEO office467935.7
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3222783111088None1.1.4Supplying heavy gauge PVC conduit pipe . dia mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws.( 40 mm dia 2.5 mm thick)( B.R- 149.00+ASL 3%)(Common SR 2023-24 Volume-6 Pg.No. 419) ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.m153.47153.4780.0FalseNoneNoneFalseNoneFalse12277.60
3222784111088None1.2.1Supplying heavy gauge PVC conduit pipe mm dia.mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary ( 19/20 mm dia 2 mm thick) (( B.R- 66.00+ASL 3% )(Common SR 2023-24 Volume-6 Pg.No. 419) ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.m67.9867.98280.0FalseNoneNoneFalseNoneFalse19034.40
3222785111088None1.2.2Supplying heavy gauge PVC conduit pipe mm dia.mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary(25 mm dia 2 mm thick)(( B.R- 78.00+ASL 3% )(Common SR 2023-24 Volume-6 Pg.No.419) ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.m80.3480.34170.0FalseNoneNoneFalseNoneFalse13657.80
3222786111088None1.3.1Supplying heavy gauge PVC Conduit Pipe . dia mmthick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary.(19/20 mm dia 2 mm thick)(( B.R- 68.00+ASL 3% )(Common SR 2023-24 Volume-6 Pg.No.419) ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.m70.0470.04200.0FalseNoneNoneFalseNoneFalse14008.00
3222787111088None1.3.2Supplying heavy gauge PVC Conduit Pipe . dia mmthick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary.(25 mm dia 2 mm thick)( B.R- 79.00+ASL 3%)(Common SR 2023-24 Volume-6 Pg.No.419) ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.m81.3781.37180.0FalseNoneNoneFalseNoneFalse14646.60
3222788111088None1.5.1Supplying and fixing PVC/metal conduit Deep junction box(19/20 mm deep Junction box)(( B.R- 49.00+ASL 3% )(Common SR 2023-24 Volume-6 Pg.No.419) ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.Each50.4750.4720.0FalseNoneNoneFalseNoneFalse1009.40
3222789111088None1.5.2Supplying and fixing PVC/metal conduit Deep junction box(25 mm deep Junction box)( B.R- 56.00+ASL 3% )(Common SR 2023-24 Volume-6 Pg.No.420) ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.Each57.6857.6815.0FalseNoneNoneFalseNoneFalse865.20
3222790111088None1.9.1Supplying PVC/GI flexible conduit pipe mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300 mm using NF screws and on either end of the pipe terminated completely(20 mm)( B.R- 19.00+ASL 3%)(Common SR 2023-24 Volume-6 Pg.No.420) ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.m19.5719.574.0FalseNoneNoneFalseNoneFalse78.280
3222791111088None1.9.2Supplying PVC/GI flexible conduit pipe mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300 mm using NF screws and on either end of the pipe terminated completely(25 mm)( B.R- 22.00+ASL 3%)(Common SR 2023-24 Volume-6 Pg.No.420) ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.m22.6622.6615.0FalseNoneNoneFalseNoneFalse339.90
3222792111088None1.9.4Supplying PVC/GI flexible conduit pipe mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300 mm using NF screws and on either end of the pipe terminated completely(40 mm)( B.R- 36.00+ASL 3%)(Common SR 2023-24 Volume-6 Pg.No.420) ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.m37.0837.088.0FalseNoneNoneFalseNoneFalse296.640
3222793111088None1.13Supplying And Fixing Metal Fan Box with Round Hook.( B.R- 117.00+ASL 3% )(Common SR 2023-24 Volume-6 Pg.No.421) ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.No120.51120.518.0FalseNoneNoneFalseNoneFalse964.080
3222794111088None2.2.1Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet(Short point upto 3m from tapping point to out let via switch box)( B.R- 269+ASL 3% ) (Common SR 2023-24 Volume-6 Pg.No.422) ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.Point277.07277.0728.0FalseNoneNoneFalseNoneFalse7757.960
3222795111088None2.2.2Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet(Medium point above 3m upto 6m from tapping point to out letvia switch box)( B.R- 379.00+ASL 3% )(Common SR 2023-24 Volume-6 Pg.No.422) ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.Point390.37390.3717.0FalseNoneNoneFalseNoneFalse6636.290
3222796111088None2.2.3Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet(Long point above 6m upto 10m from tapping point to out let viaswitch box)( B.R- 555.00+ASL 3%)(Common SR 2023-24 Volume-6 Pg.No.422) ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.Point571.65571.6530.0FalseNoneNoneFalseNoneFalse17149.50
3222797111088None2.3.2Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.(1.5 mm2)( B.R- 26.00+ASL 3%)(Common SR 2023-24 Volume-6 Pg.No.422) ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.m26.7826.78450.0FalseNoneNoneFalseNoneFalse12051.00
3222798111088None2.3.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments(2.5 mm2)( B.R- 42.00+ASL 3%)(Common SR 2023-24 Volume-6 Pg.No.422) ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.m43.2643.261500.0FalseNoneNoneFalseNoneFalse64890.00
3222799111088None2.3.4Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.(4 mm2)( B.R- 63.00+ASL 3% )(Common SR 2023-24 Volume-6 Pg.No.423) ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.m64.8964.89850.0FalseNoneNoneFalseNoneFalse55156.50
3222800111088None2.3.5Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.(6 mm2)( B.R- 92.00+ASL 3%)(Common SR 2023-24 Volume-6 Pg.No.423) ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.m94.7694.76500.0FalseNoneNoneFalseNoneFalse47380.00
3222801111088None3.4.1Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting inBrick/Stone/C.C wall(1-2 Way)( B.R- 138.00+ASL 3%)(Common SR 2023-24 Volume-6 Pg.No.425) ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.Each142.14142.1410.0FalseNoneNoneFalseNoneFalse1421.40
3222802111088None3.4.2Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting inBrick/Stone/C.C wall(3 Way)( B.R- 159.00+ASL 3%)(Common SR 2023-24 Volume-6 Pg.No.425) ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.Each163.77163.778.0FalseNoneNoneFalseNoneFalse1310.160
3222803111088None3.4.3Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting inBrick/Stone/C.C wall(4-5 Way)( B.R- 177.00+ASL 3% )(Common SR 2023-24 Volume-6 Pg.No.425) ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.Each182.31182.318.0FalseNoneNoneFalseNoneFalse1458.480
3222804111088None3.4.4Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting inBrick/Stone/C.C wall(6 Way)( B.R- 220.00+ASL 3%)(Common SR 2023-24 Volume-6 Pg.No.425) ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.Each226.6226.610.0FalseNoneNoneFalseNoneFalse2266.00
3222805111088None3.4.5Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting inBrick/Stone/C.C wall(8 Way)( B.R- 261.00+ASL 3% )(Common SR 2023-24 Volume-6 Pg.No.425) ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.Each268.83268.8310.0FalseNoneNoneFalseNoneFalse2688.30
3222806111088None3.5.1Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete onthe existing metal/PVC box.(1 to 2 Module)( B.R- 137.00+ASL 3% )(Common SR 2023-24 Volume-6 Pg.No.425) ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.Each141.11141.1110.0FalseNoneNoneFalseNoneFalse1411.10
3222807111088None3.5.2Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete onthe existing metal/PVC box.(3 Module)( B.R- 161.00+ASL 3% )(Common SR 2023-24 Volume-6 Pg.No.425) ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.Each165.83165.838.0FalseNoneNoneFalseNoneFalse1326.640
3222808111088None3.5.3Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete onthe existing metal/PVC box.(4 Module)( B.R- 175.00+ASL 3% )(Common SR 2023-24 Volume-6 Pg.No.425) ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.Each180.25180.258.0FalseNoneNoneFalseNoneFalse1442.00
3222809111088None3.5.4Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete onthe existing metal/PVC box.(6 Module)( B.R- 234.00+ASL 3% )(Common SR 2023-24 Volume-6 Pg.No.425) ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.Each241.02241.0210.0FalseNoneNoneFalseNoneFalse2410.20
3222810111088None3.5.5Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete onthe existing metal/PVC box.(8 Module)( B.R- 284.00+ASL 3%)(Common SR 2023-24 Volume-6 Pg.No.425) ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.Each292.52292.5210.0FalseNoneNoneFalseNoneFalse2925.20
3222811111088None3.6.1Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.(6A One Way Switch)( B.R- 102.00+ASL 3% )(Common SR 2023-24 Volume-6 Pg.No.426) ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.Each105.06105.0645.0FalseNoneNoneFalseNoneFalse4727.70
3222812111088None3.6.2Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.(6A Two Way Switch)( B.R- 166.00+ASL 3% )(Common SR 2023-24 Volume-6 Pg.No.426) ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.Each170.98170.982.0FalseNoneNoneFalseNoneFalse341.960
3222813111088None3.6.3Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.(6A Three Way socket)( B.R- 171.00+ASL 3%+ )(Common SR 2023-24 Volume-6 Pg.No.426) ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.Each176.13176.1320.0FalseNoneNoneFalseNoneFalse3522.60
3222814111088None3.6.4Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.(Stepped Fan Regulator Two Module)( B.R- 357.00+ASL 3%)(Common SR 2023-24 Volume-6 Pg.No.426) ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.Each367.71367.7115.0FalseNoneNoneFalseNoneFalse5515.650
3222815111088None3.6.7Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.(16A One Way Switch)( B.R- 180.00+ASL 3%)(Common SR 2023-24 Volume-6 Pg.No.426) ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.Each185.4185.44.0FalseNoneNoneFalseNoneFalse741.60
3222816111088None3.6.8Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.(6A Bell Push)( B.R- 177.00+ASL 3%)(Common SR 2023-24 Volume-6 Pg.No.426) ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.Each182.31182.311.0FalseNoneNoneFalseNoneFalse182.310
3222817111088None3.6.9Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.(32A DP Switch)( B.R- 236.00+ASL 3%)(Common SR 2023-24 Volume-6 Pg.No.426) ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.Each335.78335.7812.0FalseNoneNoneFalseNoneFalse4029.360
3222818111088None3.6.10Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.(6/16A Universal Socket)( B.R- 236.00+ASL 3% )(Common SR 2023-24 Volume-6 Pg.No.426) ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.Each243.08243.0812.0FalseNoneNoneFalseNoneFalse2916.960
3222819111088None3.6.11Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.(TV/Telephone Socket)( B.R- 156.00+ASL 3% )(Common SR 2023-24 Volume-6 Pg.No.426) ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.Each160.68160.682.0FalseNoneNoneFalseNoneFalse321.360
3222820111088None3.14.4Supplying And fixing/replacing of 6/16/32A electricalaccessories on existing switch board.(16A Three Pin Top)( B.R- 87.00+ASL 3%)(Common SR 2023-24 Volume-6 Pg.No.427) ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.No89.6189.612.0FalseNoneNoneFalseNoneFalse179.220
3222821111088None5.1Supplying push button operated direct online starter with an antiweld silver cadmium oxide contactor with replaceable fixed and moving contacts and bimetallic thermal overload relay help in anticorrosion treated sheet steel or iron clad enclosure and fixing the same to suitable capacity wires for 230/440 V 1/3 phase motor upto 5 HP( B.R- 1927.00+ASL 3% )(Common SR 2023-24 Volume-6 Pg.No.431) ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.Each1984.811984.811.0FalseNoneNoneFalseNoneFalse1984.810
3222822111088None5.6.4Supply and fixing polished wood board made of not less than 15mm thick plank on both sides of not more than 2 pieces and fixing the same to the wall using tapered invertedwooden plugs screws(12" x 12" x 2")( B.R- 181.00+ASL 3% )(Common SR 2023-24 Volume-6 Pg.No.531) ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.Each186.43186.431.0FalseNoneNoneFalseNoneFalse186.430
3222823111088None5.7.4Supplying & fixing of Porcelain fuse channel with cut out onexisting wooden/panel using necessary nuts, bolts and washers.(100 A)( B.R- 691.00+ASL 3% )(Common SR 2023-24 Volume-6 Pg.No.431) ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.Each711.73711.732.0FalseNoneNoneFalseNoneFalse1423.460
3222824111088None5.11.2Supplying of on load change over switches 4 poles, AC- 23A Duty, 415V, 50Hz, AC Supply. (Open Execution)(100 A)( B.R- 7090.00+ASL 3% )(Common SR 2023-24 Volume-6 Pg.No.432) ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.Each7302.77302.71.0FalseNoneNoneFalseNoneFalse7302.70
3222825111088None5.15.9Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.FOUR Pole(100 A 25 kA)( B.R- 8487.00+ASL 3%)(Common SR 2023-24 Volume-6 Pg.No.434) ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.Each8741.618741.611.0FalseNoneNoneFalseNoneFalse8741.610
3222826111088None5.18.2Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.(40 A SP)( B.R- 739.00+ASL 3%)(Common SR 2023-24 Volume-6 Pg.No.434) ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.Each761.17761.178.0FalseNoneNoneFalseNoneFalse6089.360
3222827111088None5.18.5Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.(40 A DP)( B.R- 1060.00+ASL 3% )(Common SR 2023-24 Volume-6 Pg.No.434) ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.Each1091.81091.88.0FalseNoneNoneFalseNoneFalse8734.40
3222828111088None5.18.7Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.(6-32 A TPN)( B.R- 1717.00+ASL 3%)(Common SR 2023-24 Volume-6 Pg.No.434) ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.Each1768.511768.513.0FalseNoneNoneFalseNoneFalse5305.530
3222829111088None5.18.9Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.(50-63 A TPN)( B.R- 3088.00+ASL 3% )(Common SR 2023-24 Volume-6 Pg.No.435) ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.Each3180.513180.511.0FalseNoneNoneFalseNoneFalse3180.510
3222830111088None5.19.4Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clA, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure(12 Way SP & N)( B.R- 1863.00+ASL 3%)(Common SR 2023-24 Volume-6 Pg.No.435) ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.Each1918.891918.892.0FalseNoneNoneFalseNoneFalse3837.780
3222831111088None5.20.6Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V upto 300mA sensitivity on existing wood/panel board.(16-25A 4 pole)( B.R- 5066.00+ASL 3%)(Common SR 2023-24 Volume-6 Pg.No.435) ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.Each5217.985217.981.0FalseNoneNoneFalseNoneFalse5217.980
3222832111088None5.21Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board.( B.R- 9255.00+ASL 3% )(Common SR 2023-24 Volume-6 Pg.No.435) ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.Each9532.659532.651.0FalseNoneNoneFalseNoneFalse9532.650
3222833111088None5.23Supplying, fixing and wiring 0 to 30V Direct Reading DCVoltmeter/Ammeter( B.R- 690.00+ASL 3% )(Common SR 2023-24 Volume-6 Pg.No.435) ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.Each710.7710.71.0FalseNoneNoneFalseNoneFalse710.70
3222834111088None5.29Supplying, fixing and wiring 3 Phase Digital Ammeter /Voltmeter( B.R- 1425.00+ASL 3% )(Common SR 2023-24 Volume-6 Pg.No.436) ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.Each1467.751467.751.0FalseNoneNoneFalseNoneFalse1467.750
3222835111088None5.27Supplying, fixing and wiring rotary selector switch suitablefor Ammeter( B.R- 200.00+ASL 3%)(Common SR 2023-24 Volume-6 Pg.No.436) ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.Each206.0206.01.0FalseNoneNoneFalseNoneFalse206.00
3222836111088None5.28Supplying, fixing and wiring rotary selector switch suitablefor Voltmeter( B.R- 160+ASL 3%)(Common SR 2023-24 Volume-6 Pg.No.436) ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.Each164.8164.81.0FalseNoneNoneFalseNoneFalse164.80
3222837111088None5.34Supplying, fixing and wiring 50/5 to 400/5A 5VA burden Current Transformer Class 0.5 accuracy with Tape Wound.( B.R- 562.00+ASL 3%)(Common SR 2023-24 Volume-6 Pg.No.436) ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.Each578.86578.863.0FalseNoneNoneFalseNoneFalse1736.580
3222838111088None5.35Supplying, fixing and wiring Electronic Trivector Meter (ETV) 5 to 32/63 A three phase 4 wire whole current class-1 AccuracyEnergy Meter.( B.R- 5705.00+ASL 3% )(Common SR 2023-24 Volume-6 Pg.No.436) ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.Each5876.155876.151.0FalseNoneNoneFalseNoneFalse5876.150
3222839111088None5.38Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz12/24V D.C.( B.R- 515.00+ASL 3% )(Common SR 2023-24 Volume-6 Pg.No.436) ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.Each530.45530.453.0FalseNoneNoneFalseNoneFalse1591.350
3222840111088None5.40.1Supplying . A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete(100 A 4 x 30 x 6 mm Aluminium Strips)( B.R- 2465.00+ASL 3% )(Common SR 2023-24 Volume-6 Pg.No.437) ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.m2538.952538.952.0FalseNoneNoneFalseNoneFalse5077.90
3222841111088None5.41.1Supplying and fixing angle iron frame work fabricated out ofM.S. angle iron. and M.S. Flat.with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint(.40 x 40 x 6 mm)( B.R- 305.00+ASL 3% )(Common SR 2023-24 Volume-6 Pg.No.437) ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.m314.15314.152.0FalseNoneNoneFalseNoneFalse628.30
3222842111088None5.42.1Fabricating supplying and mounting MS box made outSWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete.(14 SWG)( B.R- 0.50+ASL 3%)(Common SR 2023-24 Volume-6 Pg.No.437) ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.Sq CM0.520.5230000.0FalseNoneNoneFalseNoneFalse15600.00
3222843111088None6.4.1Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/79 and also comply with IS: 1709/1984 with latest amendment, Rated voltage 220 V/50 Hz, Rated power input 48 W +/- 10 %, Rated current As per IS:374/79, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value 4.2 CMM / W, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201, as per IS specification, Motor winding. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 V, Insulation resistance Shall not be less than Two Mega Ohms (2M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, W& current, Air Delivery & Fan Speed as per IS:374/1979 with latest amendment, 2 year manufacturer Warranty.(48" Sweep 5 Star (1200 mm)( B.R- 2677.00+ASL 3%)(Common SR 2023-24 Volume-6 Pg.No.447) ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.Each2757.312757.3115.0FalseNoneNoneFalseNoneFalse41359.650
3222844111088None13.10Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S'' hook with fan regulator to the existing board together with supplying and fixing 5 A. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring.( B.R- 171.00+ASL 3% )(Common SR 2023-24 Volume-6 Pg.No.474) ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.Each176.13176.1315.0FalseNoneNoneFalseNoneFalse2641.950
17173969370000NoneNoneElectricalPart B Lift Work1477682.83
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3222845111089None14.4.1Design, supplying, erecting testing and commissioning of - passenger/Bed -cum-passenger hospital lift with speed of 1 mtr per second, variable voltage variable frequency drive, with or without machine room for the available well size, operating at 415 V 3 phase 52 cycles AC supply,powder coated/stainless steel car entrance doors enclosures with suitable colour vinyl flooring, LED car illumination, emergency light, intercom and fan as desired by the user, central opening/side opening door with or without atendant operation, 7 segment display buttons, call register indicator, fireman drive, SS handrails inside cr, full length infrared curtain in car door, automatic rescue divice with batteries, voice announcing in reginol/international langues, Braille buttons with one year warranty and maintenance with necessary scaffolding and minor civil works like fixing of guide rail, counter weight etc.,(Chapter-14 Elevators)(6 Passengers (D With out machine room-SS Finish) Capacity 3 Stops)( B.R- 1375286.00+ASL 3% )(Common SR 2023-24 Volume-6 Pg.No.476) ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.Job1416544.581416544.581.0FalseNoneNoneFalseNoneFalse1416544.580
3222846111089None32.081.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975(25 Sqmm, 4 Core, (13 GI Strips - 4 x 0.8 mm)( B.R- 179844.00+ASL 3% )(Common SR 2023-24 Volume-6 Pg.No.349) ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.Km185239.32185239.320.08FalseNoneNoneFalseNoneFalse14819.14560
3222847111089None1.1.2Supplying heavy gauge PVC conduit pipe . dia mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws.(25 mm dia 2 mm thick)( B.R- 81.00+ASL 3%) (Common SR 2023-24 Volume-6 Pg.No.419) ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.m83.4383.43100.0FalseNoneNoneFalseNoneFalse8343.00
3222848111089None1.9.1Supplying PVC/GI flexible conduit pipe mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300 mm using NF screws and on either end of the pipe terminated completely(20 mm)( B.R- 19.00+ASL 3% )(Common SR 2023-24 Volume-6 Pg.No.420) ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.m19.5719.5710.0FalseNoneNoneFalseNoneFalse195.70
3222849111089None2.3.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.(2.5 mm2)( B.R- 42.00+ASL 3% )(Common SR 2023-24 Volume-6 Pg.No.422) ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.m43.2643.2650.0FalseNoneNoneFalseNoneFalse2163.00
3222850111089None2.3.4Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments(4 mm2)( B.R- 63.00+ASL 3% )(Common SR 2023-24 Volume-6 Pg.No.422) ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.m64.8964.8950.0FalseNoneNoneFalseNoneFalse3244.50
3222851111089None2.2.2Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.(Medium point above 3m upto 6m from tapping point to out let via switch box)( B.R- 379.00+ASL 3% )(Common SR 2023-24 Volume-6 Pg.No.422) ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.Point390.37390.376.0FalseNoneNoneFalseNoneFalse2342.220
3222852111089None3.3.3Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.(4-5 Way)( B.R- 137.00+ASL 3%)(Common SR 2023-24 Volume-6 Pg.No.425) ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.Each141.11141.113.0FalseNoneNoneFalseNoneFalse423.330
3222853111089None3.5.3Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.(4 Module)( B.R- 175.00+ASL 3% )(Common SR 2023-24 Volume-6 Pg.No.425) ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.Each180.25180.254.0FalseNoneNoneFalseNoneFalse721.00
3222854111089None3.6.1Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.(6A One Way Switch)( B.R- 102.00+ASL 3% )(Common SR 2023-24 Volume-6 Pg.No.426) ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.Each105.06105.064.0FalseNoneNoneFalseNoneFalse420.240
3222855111089None3.6.3Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.(6A Three Way socket)( B.R- 171.00+ASL 3% )(Common SR 2023-24 Volume-6 Pg.No.426) ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.Each176.13176.134.0FalseNoneNoneFalseNoneFalse704.520
3222856111089None5.15.9Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.(100 A 25 kA FOUR Pole)( B.R- 8487.00+ASL 3% )(Common SR 2023-24 Volume-6 Pg.No.434) ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.Each8741.618741.611.0FalseNoneNoneFalseNoneFalse8741.610
3222857111089None5.20.6Supplying, fixing and wiring Residual current circuit breaker (RCCB)240/450V upto 300mA sensitivity on existing wood/ panel board.(16-25A 4 pole)( B.R- 5066.00+ASL 3% )(Common SR 2023-24 Volume-6 Pg.No.435) ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.Each5217.985217.981.0FalseNoneNoneFalseNoneFalse5217.980
3222858111089None11.3.2Supplying of .feet -PVC Batten with integrated LED tube .W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V@ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.(LED light fitting 1 x 4' - 20/22 W)( B.R- 690.00+ASL 3% )(Common SR 2023-24 Volume-6 Pg.No.460) ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.Each710.7710.74.0FalseNoneNoneFalseNoneFalse2842.80
3222859111089None13.7.1Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling / rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clamps.(On wall/ ceiling / Rafter / Girders)( B.R- 122.00+ASL 3% )(Common SR 2023-24 Volume-6 Pg.No.462) ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.Each125.66125.664.0FalseNoneNoneFalseNoneFalse502.640
3222860111089None12.57Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc. using 40 mm dia 2.9 mm thick 2.5m long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode.The funnel should be enclosed in a CC chamber of 400x400x400 mm with a cast iron cover. The earth electrode shall have staggered holes of 12 mm dia and the electrode should be covered 150 mm all-round with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts.( B.R- 4256.00+ASL 3% )(Common SR 2023-24 Volume-6 Pg.No.471) ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.No4383.684383.682.0FalseNoneNoneFalseNoneFalse8767.360
3222861111089None12.58.1GI/Copperstripsforgroundingconnections,usingnecessaryfixingmaterials as required.(25 x 3 mm GI strip)( B.R- 82.00+ASL 3% )(Common SR 2023-24 Volume-6 Pg.No.471) ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.m84.4684.4620.0FalseNoneNoneFalseNoneFalse1689.20
17173969370000NoneNoneElectricalPart C Transformer Commissioning231360.07
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3222862111090None1.10 ,1.1.1 & 2.02Supply & Erection of PSCC Pole - 9 Mtr Long, 300 Kg WL (Dwg No. BESCOM/GM/QS&S/55 Dtd 24.11.2018) as per REC Standards including Digging of Pit 1.8 Mtr depth for errection of 9 to 10 Mtr Long Steel/RCC/PSCC supports as per approved Drawing for Ordinary Soil and Erection of RCC/PSCC Pole of 9 to 10 Mtr long in a pit of 1.8 Mtr depth (Item no 1.10 page 3 of 81 and Item no 1.1.1 and 2.02 page 43 & 44 of 81 Volume-6) (Material + Labour ) ( B.R- 6794.00+ASL 3% )(Common SR 2023-24 Volume-6 Pg.No.339,379&380 ) ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.No6997.826997.821.0FalseNoneNoneFalseNoneFalse6997.820
3222863111090None1.06 ,1.1.1 & 2.02Supply & Erection of PSCC Pole - 9 Mtr Long, 200 Kg WL (Dwg No. BESCOM/GM/QS&S/50 Dtd 24.11.2018) as per REC Standards including Digging of Pit 1.8 Mtr depth for errection of 9 to 10 Mtr Long Steel/RCC/PSCC supports as per approved Drawing for Ordinary Soil and Erection of RCC/PSCC Pole of 9 to 10 Mtr long in a pit of 1.8 Mtr depth (Item no 1.06 page 3 of 81 and Item no 1.1.1 and 2.02 page 43 & 44 of 81 Volume-6) (Material + Labour )( B.R- 5941.00+ASL 3%)(Common SR 2023-24 Volume-6 Pg.No.339, 379 & 380) ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.No6119.236119.231.0FalseNoneNoneFalseNoneFalse6119.230
3222864111090None9.(a)Supply & providing of 11 kV, Horizontal Cross Arm with HT Single Top supports, clamps, bolts, nuts & washers - MS For RCC Pole (C,D.S Pg No 341/635 I .No 9.(a)) (Material + Labour )( B.R- 918.00+ASL 3% ) ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.Set945.54945.543.0FalseNoneNoneFalseNoneFalse2836.620
3222865111090None2.04, supplying of Cross Arms (MS & GI) as per IS-1977 of 11 kV, Special 3 Pin Cross Arm - GI ( (Item no 2.04 page no 3 of 81 ) (Material ) B.R- 1151.00+ASL 3% )(Common SR 2023-24 Volume-6 Pg.No.339) ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.No1185.531185.532.0FalseNoneNoneFalseNoneFalse2371.060
3222866111090None6.06Supply & Providing of 11 kV, 5 kN Composite/Polymeric Pin Insulator (24 mm dia FRP Rod) (Item no 6.06 page no 5 of 81) (Material )( B.R- 205.00+ASL 3%)(Common SR 2023-24 Volume-6 Pg.No.341) ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.No211.15211.159.0FalseNoneNoneFalseNoneFalse1900.350
3222867111090None6.02Supply & Providing of 11 kV GI Pin for 11 kV Ceramic Shell Insulator (Item no 6.02 page no 5 of 81) (Material )( B.R- 66.00+ASL 3%)(Common SR 2023-24 Volume-6 Pg.No.341) ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.No67.9867.985.0FalseNoneNoneFalseNoneFalse339.90
3222868111090None6.10Supply & Providing of 11 kV, 45 kN Polymeric Insulator(Item no 6.10 page no 5 of 81) (Material )( B.R- 186.00+ASL 3% )(Common SR 2023-24 Volume-6 Pg.No.341) ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.No191.58191.586.0FalseNoneNoneFalseNoneFalse1149.480
3222869111090None7.02, & 6.02Supply & stringing of Rabbit ACSR (6/3.35 mm Al + 1/3.35 mm St), Std Wt: 214 Kg/KM and Stringing of Conductor for Rabbit ACSR (Item no 7.02 page no 5 of 81 and 6.02 page no 46 of 81) (Material + Labour )( B.R-62898.00+ASL 3% )(Common SR 2023-24 Volume-6 Pg.No.382) ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.Km64784.9464784.940.103FalseNoneNoneFalseNoneFalse6672.848820
3222870111090None9.02Supplying of PG Clamp Rabbit to Rabbit (Item no 9.02 page no 6 of 81) (Material )( B.R- 102.00+ASL 3%)(Common SR 2023-24 Volume-6 Pg.No.342) ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.No105.06105.066.0FalseNoneNoneFalseNoneFalse630.360
3222871111090None2.16 & 2.08Supply of Spiral Earth Electrode and Providing Spiral Earth Electrode type earthing (without charcoal, salt etc.,) (Item no 2.16 page no 4 of 81 and 2.08 page no 44 of 81) (Material + Labour )( B.R- 332.00+ASL 3%)(Common SR 2023-24 Volume-6 Pg.No.380) ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.No341.96341.961.0FalseNoneNoneFalseNoneFalse341.960
3222872111090None68.17 & 5.15Supply & Fixing of Caution/Danger Board (Item no 68.17 page no 32 of 81 and 5.15 page no 45 of 81) (Material + Labour )( B.R- 230.00+ASL 3% )(Common SR 2023-24 Volume-6 Pg.No368 & 381) ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.No236.9236.91.0FalseNoneNoneFalseNoneFalse236.90
3222873111090None4.02 & 5.09Supply & Fixing of GI Barbed wire (12 Mtr/Kg) (Item no 4.02 page no 4 of 81 and 5.09 page no 45 of 81) (Material + Labour )( B.R- 131.00+ASL 3% )(Common SR 2023-24 Volume-6 Pg.No.340 & 381) ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.Each134.93134.933.0FalseNoneNoneFalseNoneFalse404.790
3222874111090NoneS.L No.1Supply & Erection of DP Transformer Structure using PSCC Pole - 9 Mtr Long, 300 Kg WL (Including Cost of Poles) (C,D.S Pg No 416/635 Sl.No 1) (Material + Labour )( B.R- 34651.00+ASL 3%) ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.Set35690.5335690.531.0FalseNoneNoneFalseNoneFalse35690.530
3222875111090None24 (a)Supply & Providing Guy set with No. 15 Strain Insulator & Concreting materials as per Dwg No. BESCOM/GM/CP/7 Dt: 24.10.07 (C,D.S Pg No 344/635 I .No 24.(a)) (Material + Labour )( B.R- 1763.00+ASL 3% ) ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.Set1815.891815.892.0FalseNoneNoneFalseNoneFalse3631.780
3222876111090None26(g)Labour for Guy concreting with Boulders, Mud & Sand (300x300x450 mm)As per Drawing No. BESCOM/GM/CP/7 Dt: 24.10.07 (C,D.S Pg No 345/635 I .No 26.(g)(Labour )( B.R- 250.00+ASL 3% ) ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.Set257.5257.52.0FalseNoneNoneFalseNoneFalse515.00
3222877111090NoneSI.No 6Supply & Fixing of 11kV/433V, 25 kVA, 3 Phase, 50 Cys Distribution Transformer BEE - 5 Star Rated with Oil (C,D.S-24 Pg No 370/635 SI.No.6) (Material + Labour )( B.R- 107187+ASL 3% ) ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.No110402.61110402.611.0FalseNoneNoneFalseNoneFalse110402.610
3222878111090NoneSI.No .6Supply & Fixing of Earthing materials pipe type for grounding (Single Electrode with accessories) (C,D.S-24 Pg No 370/635 SI.No.7) (Material + Labour )( B.R- 2678.00+ASL 3% ) ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.Set2758.342758.343.0FalseNoneNoneFalseNoneFalse8275.020
3222879111090None68.17 & 5.15Supply & Fixing of Caution/Danger Board (Item no 68.17 page no 32 of 81 and 5.15 page no 45 of 81) (Material + Labour )( B.R- 230.00+ASL 3% )(Common SR 2023-24 Volume-6 Pg.No.368 &381 ) ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.No236.9236.92.0FalseNoneNoneFalseNoneFalse473.80
3222880111090None8.02Supply & providing of 8 SWG GI Wire (4.064 mm Dia), Std Wt: 131 Kg/KM (Item no 8.02 page no 5 of 81) (Material )( B.R- 75040.00+ASL 3% )(Common SR 2023-24 Volume-6 Pg.No.341) ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.MT77291.277291.20.01FalseNoneNoneFalseNoneFalse772.9120
3222881111090None8.01Supply & providing of 7/10 SWG Guy Wire (7/3.251 mm Dia), Std Wt: 680 Kg/KM (Item no 8.01 page no 5 of 81) (Material)( B.R- 77226.00+ASL 3%)(Common SR 2023-24 Volume-6 Pg.No.341) ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.MT79542.7879542.780.01FalseNoneNoneFalseNoneFalse795.42780
3222882111090None19.02 & 13.06Supply & providing of 10 kV, 5 kA Lightning Arrester Polymeric type with GROUND DISCONNECTOR and Fixing of 3 Nos Lightning Arrestor including wiring (Item no 19.02 page 9 of 81 and Item no 13.06 48 of 81 Volume-6) (Material + Labour )( B.R- 1703.00+ASL 3%)(Common SR 2023-24 Volume-6 Pg.No.345 & 384) ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.Set1754.091754.091.0FalseNoneNoneFalseNoneFalse1754.090
3222883111090None17.01 & 15.03Supply & providingLT Protection Kit (Dwg No. BESCOM/GM/QS&S/10 Dtd 24.11.2018) and Fixing of LT Protection Kit (Item no 17.01 page 9 of 81 and Item no 15.03 49of 81 Volume-6) (Material + Labour )( B.R-2379.00+ASL 3% )(Common SR 2023-24 Volume-6 Pg.No.345 & 385) ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.No2450.372450.371.0FalseNoneNoneFalseNoneFalse2450.370
3222884111090None15.04Wiring of 1 Circuit of LT Wiring for for 25/63/100 kVA DTC to the existing LT protection Kit/Distribution Box via metering box. (includes fixing of necessary supports like 2 Pin cross arm, Spacer etc)(I.No 15.04 Pg No 49 of 81 ) (Labour)( B.R- 949.00+ASL 3% )(Common SR 2023-24 Volume-6 Pg.No.385) ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.Set977.47977.471.0FalseNoneNoneFalseNoneFalse977.470
3222885111090None14b(i)Supply & providing LT Wiring (From DTC to LT Line Through Metering Box & LT Protection Kit) SINGLE CIRCUIT i) Al Lead Wire - 50 Sqmm ( C.D.S-24 I No 14 b (i) Pg No 370 of 635 ) (Material )( B.R- 64.19+ASL 3% ) ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.Mtr66.1266.1222.0FalseNoneNoneFalseNoneFalse1454.640
3222886111090None14b(ii)Supply & providing LT Wiring (From DTC to LT Line Through Metering Box & LT Protection Kit) SINGLE CIRCUIT ii) Heavy Duty Long Barrel Copper Lug - 50 Sqmm ( C.D.S-24 I No 14 b (ii) Pg No 370 of 635 ) (Material )( B.R- 58.00+ASL 3% ) ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.No59.7459.743.0FalseNoneNoneFalseNoneFalse179.220
3222887111090None14b(iii)Supply & providing LT Wiring (From DTC to LT Line Through Metering Box & LT Protection Kit) SINGLE CIRCUIT iii) PG Clamp - Rabbit to 50 Sqmm ( C.D.S-24 I No 14 b (iii) Pg No 370 of 635 ) (Material )( B.R- 102.00+ASL 3% ) ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.No105.06105.063.0FalseNoneNoneFalseNoneFalse315.180
3222888111090None14b(iv)Supply & providing LT Wiring (From DTC to LT Line Through Metering Box & LT Protection Kit) SINGLE CIRCUIT iv) Spacer for DTC Wiring ( C.D.S-24 I No 14 b (iv) Pg No 370 of 635 ) (Material )( B.R- 42.00+ASL 3%) ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.No43.2643.262.0FalseNoneNoneFalseNoneFalse86.520
3222889111090None14b(v)Supply & providing LT Wiring (From DTC to LT Line Through Metering Box & LT Protection Kit) SINGLE CIRCUIT v) Fish Plate with necessary Clamps, bolts & nuts etc complete (Galvanised ( C.D.S-24 I No 14 b (v) Pg No 370 of 635 ) (Material )( B.R-264.00+ASL 3% ) ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.No271.92271.924.0FalseNoneNoneFalseNoneFalse1087.680
3222890111090None20.01 & 13.01Supply of 11 kV, HG Fuse Unit with Solid Core Insulator (Dwg No. BESCOM/GM/QS&S/21 Dtd 24.11.2018) & Fixing DOLO Cutout/Horn Gap Fuse including fixing of cross arm and wiring(Item no 20.01 page 9 of 81 and Item no 13.01 48 of 81 Volume-6) (Material + Labour )( B.R- 1306.00+ASL 3% )(Common SR 2023-24 Volume-6 Pg.No.345 & 384) ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.Set1345.181345.181.0FalseNoneNoneFalseNoneFalse1345.180
3222891111090None24.01 & 13.02Supply & Fixing of 11 kV, 200 Amps Single Break GOS (DwgNo.BESCOM/GM/QS&S/23 Dtd 24.11.2018) (Item no 24.01 page 11 of 81 and Item no 13.02 48 of 81 Volume-6) (Material + Labour )( B.R- 10554.00+ASL 3% )(Common SR 2023-24 Volume-6 Pg.No. 347 & 384 ) ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.Set10870.6210870.621.0FalseNoneNoneFalseNoneFalse10870.620
3222892111090None24.06 & 2.09Supply of H - Frame Set for fixing 11 kV, 200 Amps Single Break GOS - (For DP structure for providing New GOS for sectionalisation) - MS (Item no 24.06 page 11 of 81 and Item no 2.09 44 of 81 Volume-6) (Material + Labour )( B.R- 4655.00+ASL 3% )(Common SR 2023-24 Volume-6 Pg.No.374 & 380) ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.Set4794.654794.651.0FalseNoneNoneFalseNoneFalse4794.650
3222893111090None52.01Supplying of Transparent Alkathine tube 19 mm dia, 2 mm thick in coils of 30 Mtr (Item no 52.01 page 23 of 81)(Labour)( B.R- 517.00+ASL 3%)(Common SR 2023-24 Volume-6 Pg.No.359) ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.Coil532.51532.513.0FalseNoneNoneFalseNoneFalse1597.530
3222894111090None59.05Supplying of Heavy Duty Copper Terminal Long Barrel (Item no 59.05 page 23 of 81)(Labour)( B.R- 129.00+ASL 3% )(Common SR 2023-24 Volume-6 Pg.No.362) ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.No132.87132.877.0FalseNoneNoneFalseNoneFalse930.090
3222895111090None64.06 & 15.02Supply of Distribution Transformer Centre (DTC) MS Box for housing the ETV Meter 3 Phase 4 Wire 5 Amps, with associated LT CT 0.5 Accuracy Class, ring type, with wiring Clamps, B&N and all other accessories required. (EXCLUDING ETV METER) SMC metering box as above for With CT Ratio 50/5 for 15/25 kVA DTC & Fixing of LT Metering Box with clamping arrangement for mounting on the Transformer structure with necessary terminal strip and CT mounting arrangement for housing the ETV Meters and connecting to the existing ground. (Item no 64.06 page 29 of 81 and Item no 15.02 49 of 81 Volume-6) (Material + Labour )( B.R- 7393.00+ASL 3% )(Common SR 2023-24 Volume-6 Pg.No.365 & 385) ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.Set7614.797614.791.0FalseNoneNoneFalseNoneFalse7614.790
3222896111090None5.31 Supplying and fixing Electronic Trivector Meter (ETV) suitable for operation LT operation and -CT operated meter in polycarbonate body in class 0.5 accuracy as per IS 14697 andcompletely wired.(Item no 5.31 Volume-6) (Material )( B.R- 4390.00+ASL 3% )(Common SR 2023-24 Volume-6 Pg.No.436) ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.Each4521.74521.71.0FalseNoneNoneFalseNoneFalse4521.70
3222897111090None12.4.4 Rewinding a . mm ceiling fan/after using necessary gauge annealed and insulated copper wire with necessary insulating, separators vibration arresting shellac, etc including replacement of bearings if any transportation to and from the spot to workshop inclusive of releasing the refixing. for 1400mm(I.No 12.4.4 Pg No 48 of 105 ) (Labour)( B.R- 798.00+ASL 3% )(Common SR 2023-24 Volume-6 Pg.No.465) ---- including cost and conveyance of all materials, labour and other incidental charges necessary for the successful completion of work etc., complete as per standard specification of work and as directed by the Engineer in charge of the work.Each821.94821.941.0FalseNoneNoneFalseNoneFalse821.940
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17173969380000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17173969380000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17173969380001NoneNoneELIGIBILITYThe intending tenderer is instructed to note that they should abide by the detailed instructions and conditions contained in the standard tender documents KW-2 K.P.W.D. and further orders there on.None
17173969380000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17173969380000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
17173970950000NoneNoneELIGIBILITYThe responsibility of safe custody of electrical equipments/ materials, etc., shall be with the contractor until they are finally handed over to the Department.None
17173971010000NoneNoneELIGIBILITYAll necessary paper works, etc. and any other formalities required to be observed shall be the responsibility of contractor.None
17173971090000NoneNoneELIGIBILITYWhenever executing authority insist proof of having purchased the materials (used during executing the work) for verification. The contractor shall produce the purchase bills.None
17173971410000NoneNoneELIGIBILITYThe contractor is responsible for safety and security of all materials.None
17173971510000NoneNoneELIGIBILITYAll hard ware materials used for work shall be of hot dip galvanized as per IS wherever necessary.None
17173971580000NoneNoneELIGIBILITYIt is the responsibility of the contractor to pursue and obtain all necessary approvals.None
17173971660000NoneNoneELIGIBILITYThe Contractor shall submit to the employer, for his review and approval, all shop drawings, samples, materials lists, equipment data, instruction manuals, record documents, manufacturers equipment manuals, and other information required by the Contract Documents, before use and execution and before bringing the material at Site.None
17173971730000NoneNoneELIGIBILITYAs per Karnataka State Government order No. LD/300/LET/2006 Bangalore Dated 01.01.2007 and G.No. PW/134/BMS/2007 Dated 27.7.2007, a sum amounting to 1% of the bill amount will be deducted welfare fund.None
17173971820000NoneNoneELIGIBILITYConditional Tenders will not be accepted.None
17173971890000NoneNoneELIGIBILITYThe tenderer shall obtain the work done certificate in the prescribed format from the competent Authority not below the rank of Executive Engineer (District level Officer) and scan the original Certificate and attach the scanned file Certificate/ Certificates shall be produced at the time of opening of tender for physical verification.None
17173971960000NoneNoneELIGIBILITYThe tenderer shall scan the original ownership document/ lease / hire commitment Agreement scanned file to the Bid. The Original Documents shall be produced at the time of opening of Tender.None
17173972040000NoneNoneELIGIBILITYThe Employer reserves the right to reject any or all Tenders without assigning any reason.None
17173972120000NoneNoneELIGIBILITYThe tenderer should furnish Qualification and experience of the key technical and Management personnel in permanent employment with the Tenderer and those that are proposed to be deployed on this work, if work is awarded.None
17173972190000NoneNoneELIGIBILITYIt is the responsibility of the licensed electrical contractor who executes the maintenance works to get periodical services of the installations from the concerned Service Electricity Companies duly obtaining approval from the govt. electrical inspectorate as the case may be. However the department will pay the deposit/statutory fees if any after hearing the respective statutory bodies.None
17173972280000NoneNoneELIGIBILITYThe tenderer should not damage the building while execution If any damages made, tenderer should make good of it from his own cost.None
17173972370000NoneNoneELIGIBILITYThe start date for this work has to be considered from the date of issue of work order.None
17173972440000NoneNoneELIGIBILITYThe Tenderer should submit Latest GST clearance certificateNone
17173972510000NoneNoneELIGIBILITYTenderers must provide insurance to all the employees executing this work.None
17173972580000NoneNoneELIGIBILITYThe employer is not responsible for any delay in accessing Karnataka Public Procurement Portal.None
17173972650000NoneNoneELIGIBILITYThe Laboures deployed shall mandatory wear the face mask, Electrical safety hand gloves and take all safety measures to protect laboures and staff.None
17173972740000NoneNoneELIGIBILITYAs per the Govt Order No PW2BMS2019 Bangalore Dated 19-06-2019 the applicable GST shall be paid to the tenderer for PWD SR Items only.None
17173972840000NoneNoneELIGIBILITYThe Agency Should Coordinate with Civil Work.None
17173972910000NoneNoneELIGIBILITYThe agency should consider necessary ladder etc required for fixing Electrical times.None
17173972990000NoneNoneELIGIBILITYThe agency considers all labours required for fixing items.None
17173973160000NoneNoneELIGIBILITYThe agency should inspect the site before quoting the tender.None
17173973340000NoneNoneELIGIBILITYThe Labours deployed shall mandatory were face mask, hand gloves and take all safety measures to protect labours and staff as per Covid Norms.None
17173973430000NoneNoneELIGIBILITYThe quoted rates shall be excluding GST and applicable GST shall be paid separately.None
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNone3.2To qualify for award of this contract, each tenderer in its name should have in the last Five years i.e. 2019-20 to 2023-24. b) Satisfactorily completed (at least 50% of the contract value), as prime contractor, at least one similar work i.e., Providing similar nature of Electrical Work of value not less than Rs.10.89 Lakhs and Only for lift items:- who are not executed lift errection work must produce consent letter from lift Manufacturers (Otis, Kone or Mitsubishi). The consent letter shall be work specific as per tender notification duly indicating the assurance of Supply Errection & commissioning of Lifts on behalf of the identified contractor if the work is awarded to him.Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Others -- work done certificate and The tenderer must up load the consent letter from Otis, Kone or Mitsubishi
NoneNoneNoneNone3.2To qualify for award of this contract, each Tenderer in its name should have in the last five years i.e. from 2019-20 to 2023-24 c) Executed in any one year, during last five years the following minimum quantities of work.1)Wiring for lighting /power Circuits-2640 Mtr, 2) SITC of 25 KVA Transformer-1 No, 3) Supply, erection, testing and commissioning of passenger Elevator - 1 NoPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Others -- Qty Executed List and The tenderer must up load the consent letter from Otis, Kone or Mitsubishi
NoneNoneNoneNoneThe tenderer as a Prime Contractor having valid Class-2 & above Electrical License issued by Electrical Inspectorate Govt of Karnataka and should have suitable technical, financial & managerial capabilities.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Class-2 and Above Electrical Inspectorate Registration Certificates
NoneNoneNoneNone3.6Tenderers who meet the above specified minimum qualifying criteria, will only be qualified, if their available tender capacity is more than the total tender value. The available tender capacity will be calculated as under/ Assessed available tender capacity - (AxNx2.5 - B ) Where, A-Maximum value of construction works executed in any one year during the last five years (updated 2023-24 price level) taking into account the completed as well as works in progress. N Number of years prescribed for completion of the works for which tenders are invited. 0.25 Years (03 Months) B - Value, at 2023-24 price level, of existing commitments and on-going works to be completed during the next. 0.25 Years (03 Months) (period of completion of the works for which Tenders are invited) Note: The statements showing the value of existing commitments and on-going works as well as the stipulated period of completion remaining for each of the works listed should be countersigned by the Employer in charge, not below the rank of an Executive Engineer or equivalentCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Tender capacity statement
NoneNoneNoneNoneThe Tenderer must submit ongoing and existing commitments details separately.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Ongoing and existing commitments details
NoneNoneNoneNone3.2To qualify for award of this contract each Tenderer in its name should have during last five years ie from 2019-20 to 2023-24 a) The tenders must have achieved in at least two financial years an average annual financial turnover of an amount Not less than Rs.21.77 Lakhs during last five years. with UDIN Number certified by Chartered Accountant, If Failed to Satisfy the condition tender will be rejected Note: The returns submitted to the I.T. along with the Profit and Loss account statement, Balance sheet should be uploaded for the financial turnover criteriaFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Balance Sheet & Profit and Loss Statement certified by a Registered Charted Account
NoneNoneNoneNone3.3Each Tenderer should further demonstrate: (b) liquid assets and /or availability of credit facilities of not less than Rs.6.54 Lakhs (For Particular work only) (Credit lines/ letter of credit/ certificates from banks for meeting the fund requirement etc. (usually the equivalent of the estimated cash flow for three months in the peak construction period).Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Bankers Certificate in prescribed format
NoneNoneNoneNoneNilOthersNil
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Nil
NoneNoneNoneNoneNilOthersNil
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Nil
NoneNoneNoneNoneNilOthersNil
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Nil
NoneNoneNoneNoneNilOthersNil
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Nil
NoneNoneNoneNoneNilOthersNil
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Nil
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Class-2 and Above Electrical Inspectorate Registration CertificatesTrueTechnical Bid
Balance Sheet & Profit and Loss Statement certified by a Registered Charted AccountTrueTechnical Bid
Work done certificate issued by an officer not below the rank of Executive Engineer/ EquivalentTrueTechnical Bid
Qty Executed List and The tenderer must up load the consent letter from Otis, Kone or MitsubishiTrueTechnical Bid
Bankers Certificate in prescribed formatTrueTechnical Bid
Tender capacity statementTrueTechnical Bid
Ongoing and existing commitments detailsTrueTechnical Bid
tenderWorkLocationList
tenderAddressNone
tenderRecallDTONone