createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1717763150746
version3
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee980.00
emd78000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose27-06-2024 17:00:00
tenderQueryClose12-06-2024 17:00:00
technicalBidOpen28-06-2024 17:30:00
publishedDate07-06-2024 18:28:58
publishedByPostTP_CO_MMH
publishedByUserKPE20989 - KHAJA M
bidValidityPeriod90
noOfCalls1
preBidMeetingDateNone
preBidMeetingYnFalse
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonH HUSEN BASHA
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumberNone
mobileNumber8095987364
tenderSupplierListNone
tenderSchedule
createdTs1717763150779
version4
createdDateNone
modifiedDateNone
tenderNumberDMA/2024-25/OW/WORK_INDENT18350
titleConstruction of Proposed 3TPD MRF Centre (Material Recovery Facility) of PEB Structure At Mariyammanahalli TP Limit
descriptionConstruction of Proposed 3TPD MRF Center (Material Recovery Facility) of PEB Structure At Mariyammanahalli TP Limit
categoryWORKS
categoryTextWorks
ecv3900000.00
deptNameDirectorate of Municipal Administration
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnTrue
location2480
locationNameDMA Town Panchayat Mariyammanahalli
provisionalAmount3900000.0
groupOverheadTotal599356.18
fileNumber2024-25/TP/MMH/MRF
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17177631510000NoneNoneOther WorksConstruction of Proposed 3TPD MRF Centre (Material Recovery Facility) of PEB Structure At Mariyammanahalli TP Limit3300643.82
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3247656112375NoneMMH001KSRB 1-1.14.1: Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. (Item No. 1.14.1 Page No. 8 Vol.1 PWD SR)Cum107.1107.136.64FalseNoneNoneFalseNoneFalse3924.1440
3247657112375NoneMMH002KSRB 2-2.1.2: Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates (The cost of steel reinforcement & formwork shall be paid separately. Specification No. KBS 2.1, (Item No. 2.1.2 Page No. 15 Vol.1 PWD SR)Cum5947.25947.236.18FalseNoneNoneFalseNoneFalse215169.6960
3247658112375NoneMMH003KSRB 2-2.3.2:Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately). M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Specification No. KBS 2.3., 2.3 (Item No. 2.3.2 Page No. 16 Vol.1 PWD SR & Appendix I page No.115), For Footing Centering For Footing 8%Cum7322.47322.49.04FalseNoneNoneFalseNoneFalse66194.4960
3247659112375NoneMMH004KSRB 2-2.3.2:Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately). M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Specification No. KBS 2.3., 2.3 (Item No. 2.3.2 Page No. 16 Vol.1 PWD SR & Appendix I page No.115), For ColoumnsCum11340.011340.01.94FalseNoneNoneFalseNoneFalse21999.60
3247660112375NoneMMH005KSRB 2-2.3.2:Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately). M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Specification No. KBS 2.3., 2.3 (Item No. 2.3.2 Page No. 16 Vol.1 PWD SR & Appendix I page No.115), For Coloumns Centering For Coloumns 70%Cum7322.47322.440.7FalseNoneNoneFalseNoneFalse298021.680
3247661112375NoneMMH006KSRB 2-2.2.3.1 :Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately). M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Item No. 2.2.3 Page No. 15 Vol.1 PWD SR & Appendix I page No.115) For Plint BeamCum9820.89820.85.98FalseNoneNoneFalseNoneFalse58728.3840
3247662112375NoneMMH007KSRB 2.11 Steel Fabrication: Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening,Tonne93929.8593929.853.71FalseNoneNoneFalseNoneFalse348479.74350
3247663112375NoneMMH008KSRB 5-5.4: Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) . (Item No. 5.4 Page No. 9 Vol.2 PWD SR)Cum6708.456708.4517.43FalseNoneNoneFalseNoneFalse116928.28350
3247664112375NoneMMH009KSRB 1-1.8: Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work (Item No. 1.8 Page No. 7 Vol.1 PWD SR)Cum497.7497.7183.14FalseNoneNoneFalseNoneFalse91148.7780
3247665112375NoneMMH010KSRB 6-6.33: Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. (Item No. 6.33 Page No. 17 Vol.2 PWD SR)Sqm1292.551292.55106.06FalseNoneNoneFalseNoneFalse137087.8530
3247666112375NoneMMH011KSRB 8-8.3.1: Providing 15mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(Item No. 8.2.1, Page No. 41, Vol.2)Sqm309.75309.75225.61FalseNoneNoneFalseNoneFalse69882.69750
3247667112375NoneMMH012Providing and fixing Structural Steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-inCharge. (Item No. 11.2, Page No. 77, Vol.2)Kgs118.65118.658380.0FalseNoneNoneFalseNoneFalse994287.00
3247668112375NoneMMH013Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05 %) total coated thickness with zinc coating 120 g/m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineerin-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. (Item No. 7.38, Page No. 26, Vol.2)Sqm596.4596.4590.76FalseNoneNoneFalseNoneFalse352329.2640
3247669112375NoneMMH014KSRB 8-8.51 : Providing and applying white cement based putty of average thicknessSqm105.0105.0225.61FalseNoneNoneFalseNoneFalse23689.050
3247670112375NoneMMH015KSRB 8-8.54.1 : Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 g/L of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. One coat as per specifications and as per directions of Engineer in charge.(Item No. 8.54.1, Page No. 50, Vol.2)No76.6576.65106.06FalseNoneNoneFalseNoneFalse8129.4990
3247671112375NoneMMH016KSRB 8-8.75.2 : Finishing walls with Premium Acrylic Smooth exterior paint of required shade : Old work (one coats applied @ 0.83 l/10 m²) including preparing the surface after thoroughly cleaning the surface to remove all dirt,dust and foreign matter , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.(Item No. 8.75.2, Page No. 53, Vol.2)No76.6576.65106.06FalseNoneNoneFalseNoneFalse8129.4990
3247672112375NoneMMH017KSRB 11-11.6.1:Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (Item No. 11.6.1, Page No. 76, Vol.2)Sqm2764.652764.6522.5FalseNoneNoneFalseNoneFalse62204.6250
3247673112375NoneMMH018KSRB 11-11.8.4:Extra for providing 2 HP Mild Steel Auto Reverse Shutter Gearbox for operating rolling shutters including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.(Item No. 11.8.4, Page No. 77, Vol.2)No25920.325920.32.0FalseNoneNoneFalseNoneFalse51840.60
3247674112375NoneMMH019KSRB 11-11.35.1.1:Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For Fixed Portion: Powder coated aluminium (minimum thickness of powder coating 50 micron) including cost of materials, labour, usage charges of machinery complete as per specifications..(Item No. 11.35.1.1, Page No. 87, Vol.2)Kg474.6474.6240.0FalseNoneNoneFalseNoneFalse113904.00
3247675112375NoneMMH020Fabricating supplying and mounting MSboxmade out ....SWG suitableforfloor /wallmounting, fullyweather proofwith provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof lockingarrangements, with suitable size clamps with necessarycable entry pipe with gland and box should be finishedwith7tanks treatment withpowder coatedpaint and finally finished with approved colour etc., complete. PWD Ele SR 2-23-24 Page No 20 I No 5.42.2 16 SWGSq CM0.450.4543000.0FalseNoneNoneFalseNoneFalse19350.00
3247676112375NoneMMH021Supplying and fixing Moulded Case Circui t Breaker (M CCB) overthe existing wood/panel board screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Over loadand Short circuit with adjustable the rmal magnetic release Microprocessor release shall have EarthFaultasperIS/IEC60947-2.(Icu=100%lcs). In4PMCCB, all Poles shouldhaveprotection forShort-Cicrcuit/OverLoad. ForMicroprocesso rMCCBS Facility for segregating Priority and Non-Priority loads must beavailable in theMCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits toavoidanyaccidentalcontactwith live current carryingpathwith the front cover open) Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. PWD ELE SR 2023-24 Page No 17 I No 5.15.9 100 A 25 kA Four PoleEach8911.358911.351.0FalseNoneNoneFalseNoneFalse8911.350
3247677112375NoneMMH022Aluminium Busbar/Wire Pieces. ESCOM SR 2023-24 Page No 33 I No 69.04Kg142.8142.80.5FalseNoneNoneFalseNoneFalse71.40
3247678112375NoneMMH023Supplyingof Switchdisconnector fuse unit (TPN)HRC type (but without HRC fuses). With AC-23A duty and as per IS- 13947. PWD ELE SR PAGE NO 15 I NO : 5.8.1 63 AEach2427.62427.611.0FalseNoneNoneFalseNoneFalse26703.60
3247679112375NoneMMH024Supplying and fixing HRC fuse units base on existing switch / panel board.PWD ELE SR PAGE NO 15 I NO : 5.9.2 32A TO 63 AEach642.6642.61.0FalseNoneNoneFalseNoneFalse642.60
3247680112375NoneMMH025Supplying andfixingHRCfuselinkonexisting switchfusebasewith W loss as per IS-13703. PWD ELE SR PAGE NO 15 I NO : 5.10.1 upto 63 AEach305.55305.5511.0FalseNoneNoneFalseNoneFalse3361.050
3247681112375NoneMMH026Supplying and fixing HRC fuse units base on existing switch / panel board.PWD ELE SR PAGE NO 15 I NO : 5.9.1 6A TO 16 AEach345.45345.4510.0FalseNoneNoneFalseNoneFalse3454.50
3247682112375NoneMMH027SUB PANEL :Supplying&fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicatorON/OFF, energy cross-3 withShort circuitbreakingcapacity of 10 Kandcomplete wiring as required confirming to IEC60898 PWD ELE SR PAGE NO 17 I NO : 5.18.9 50-63 A TPNEach3242.43242.41.0FalseNoneNoneFalseNoneFalse3242.40
3247683112375NoneMMH028Supplyingof Switchdisconnector fuse unit (TPN)HRC type (but without HRC fuses). With AC-23A duty and as per IS- 13947. PWD ELE SR PAGE NO 15 I NO : 5.8.1 63 AEach2427.62427.610.0FalseNoneNoneFalseNoneFalse24276.00
3247684112375NoneMMH029Supplying and fixing HRC fuse units base on existing switch / panel board.PWD ELE SR PAGE NO 15 I NO : 5.9.2 32A TO 63 AEach642.6642.61.0FalseNoneNoneFalseNoneFalse642.60
3247685112375NoneMMH030Supplying andfixingHRCfuselinkonexisting switchfusebasewith W loss as per IS-13703. PWD ELE SR PAGE NO 15 I NO : 5.10.1 upto 63 AEach305.55305.5510.0FalseNoneNoneFalseNoneFalse3055.50
3247686112375NoneMMH031Outgoings: 32A Industrial socket-PWD ELE SR PAGE NO 9 I NO : 3.13.2Each575.48575.482.0FalseNoneNoneFalseNoneFalse1150.960
3247687112375NoneMMH032Outgoings: 16A Industrial socket-PWD ELE SR PAGE NO 9 I NO : 3.13.1Each407.14407.142.0FalseNoneNoneFalseNoneFalse814.280
3247688112375NoneMMH0331.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 PWD Page No 13 I NO 32, 50 Sqmm, 3.5 Core, (16 GI Strips - 4 x 0.8 mm)Mtr186.0186.050.0FalseNoneNoneFalseNoneFalse9300.00
3247689112375NoneMMH03425 Sqmm, 4 Core, (13 GI Strips - 4 x 0.8 mm)Mtr188.83188.8350.0FalseNoneNoneFalseNoneFalse9441.50
3247690112375NoneMMH03516 Sqmm, 4 Core, (11 GI Strips - 4 x 0.8 mm)Mtr148.93148.9320.0FalseNoneNoneFalseNoneFalse2978.60
3247691112375NoneMMH03610 Sqmm, 4 Core, (10 GI Strips - 4 x 0.8 mm)Mtr123.9123.920.0FalseNoneNoneFalseNoneFalse2478.00
3247692112375NoneMMH037Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 4Cx6.0 Sqmm Cu Ar cable ,3Cx6.0 Sqmm Cu Un Ar cable 3Cx 4.00 Sqmm ESCOM Page No 52 I NO 21.05Mtr21.9321.9350.0FalseNoneNoneFalseNoneFalse1096.50
3247693112375NoneMMH038Supplying & Fixing heavey guage PVC conduit type 2mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc, and shall be concealed in wall/RCC slab or exposed on fixing invrted wood plugs in case of RCC ceiling and RCC wall/stone structure or rawl plugs in case of brick wall & cement plastering the damaged portion using heavy gauage saddles at interval of 700mm using NF screws.19/20mm dia PVC 2mm thick conduit CSR Electrical SR-2023-24, ITEM NO:1.1.1 ,CH-1, PAGE NO-2Mtr72.4572.4590.0FalseNoneNoneFalseNoneFalse6520.50
3247694112375NoneMMH03925mm dia PVC 2mm thick conduit CSR Electrical SR-2023-24, ITEM NO:1.1.2 ,CH-1, PAGE NO-2Mtr85.0585.0590.0FalseNoneNoneFalseNoneFalse7654.50
3247695112375NoneMMH04032mm dia PVC 2mm thick conduit CSR Electrical SR-2023-24, ITEM NO:1.1.3 ,CH-1, PAGE NO-2Mtr111.3111.340.0FalseNoneNoneFalseNoneFalse4452.00
3247696112375NoneMMH04140mm dia PVC 2mm thick conduit CSR Electrical SR-2023-24, ITEM NO:1.1.4 ,CH-1, PAGE NO-2Mtr156.45156.4520.0FalseNoneNoneFalseNoneFalse3129.00
3247697112375NoneMMH042Supply & wiring from distribution board to looping switch boards. Laid wire size 2x2.5 Sqmm Ph-N & 1x1.5Sqmm for E for Lighting circuit wiring laid in existing conduit.1.0 Sqmm Cu FRLS wire CSR Electrical SR-2023-24, ITEM NO:2.3.1 ,CH-1, PAGE NO-5Mtr19.9519.95150.0FalseNoneNoneFalseNoneFalse2992.50
3247698112375NoneMMH0431.5 Sqmm Cu FRLS wire CSR Electrical SR-2023-24, ITEM NO:2.3.2 ,CH-1, PAGE NO-5Mtr27.327.3150.0FalseNoneNoneFalseNoneFalse4095.00
3247699112375NoneMMH0442.5 Sqmm Cu FRLS wire CSR Electrical SR-2023-24, ITEM NO:2.3.3 ,CH-1, PAGE NO-5Mtr44.144.1100.0FalseNoneNoneFalseNoneFalse4410.00
3247700112375NoneMMH0454 Sqmm Cu FRLS wire CSR Electrical SR-2023-24, ITEM NO:2.3.4 ,CH-1, PAGE NO-5Mtr52.552.5100.0FalseNoneNoneFalseNoneFalse5250.00
3247701112375NoneMMH0466 Sqmm Cu FRLS wire CSR Electrical SR-2023-24, ITEM NO:2.3.5 ,CH-1, PAGE NO-5Mtr52.552.550.0FalseNoneNoneFalseNoneFalse2625.00
3247702112375NoneMMH047Supply & wiring from switch board upto first light point & looped continously for the extent light points. Wire size 2x1.5 Sqmm Ph-N & 1x1.0Sqmm for E for point wiring laid in existing conduit.1 Light point upto 3Mtr from switch board CSR Electrical SR-2023-24, ITEM NO:2.1.1 ,CH-1, PAGE NO-5Nos299.25299.254.0FalseNoneNoneFalseNoneFalse1197.00
3247703112375NoneMMH0481 Light point above 3M upto 6Mtr from switch board CSR Electrical SR-2023-24, ITEM NO:2.1.2 ,CH-1, PAGE NO-5Nos413.7413.78.0FalseNoneNoneFalseNoneFalse3309.60
3247704112375NoneMMH0491 Light point above 6M upto 10Mtr from switch board CSR Electrical SR-2023-24, ITEM NO:2.1.3 ,CH-1, PAGE NO-5Nos598.5598.56.0FalseNoneNoneFalseNoneFalse3591.00
3247705112375NoneMMH0502 Light point above 3Mtr upto 6Mtr from switch board CSR Electrical SR-2023-24, ITEM NO:2.1.4 ,CH-1, PAGE NO-5Nos743.4743.42.0FalseNoneNoneFalseNoneFalse1486.80
3247706112375NoneMMH0512 Light point above 6Mtr upto 10Mtr from switch board CSR Electrical SR-2022-23, ITEM NO:2.1.4 ,CH-1, PAGE NO-5Nos757.05757.054.0FalseNoneNoneFalseNoneFalse3028.20
3247707112375NoneMMH0523 Light point above 6Mtr upto 10Mtr from switch board CSR Electrical SR-2023-24, ITEM NO:2.1.5 ,CH-1, PAGE NO-5Nos1086.751086.754.0FalseNoneNoneFalseNoneFalse4347.00
3247708112375NoneMMH053Switches & sockets outlets in Existing modular box, 6A one way switch CSR Electrical SR-2023-24, ITEM NO:3.6.1 ,CH-3, PAGE NO-9Nos107.1107.16.0FalseNoneNoneFalseNoneFalse642.60
3247709112375NoneMMH0546A Three Way 5 Pin Socket CSR Electrical SR-2023-24, ITEM NO:3.14.3 ,CH-3, PAGE NO-10Nos73.573.54.0FalseNoneNoneFalseNoneFalse294.00
3247710112375NoneMMH055Stepped fan regulator CSR Electrical SR-2023-24, ITEM NO:3.6.4 ,CH-3, PAGE NO-9Nos374.85374.852.0FalseNoneNoneFalseNoneFalse749.70
3247711112375NoneMMH0566/16A Universal socket CSR Electrical SR-2023-24, ITEM NO:3.6.11 ,CH-3, PAGE NO-5Nos247.8247.82.0FalseNoneNoneFalseNoneFalse495.60
3247712112375NoneMMH057SupplyofLEDStreetlight luminairewithpressurediecastaluminium housing body for optimal thermal dissipation.Lamp compartment comprising ofanti glare clear diffuserwith Injectionmouldedpolycarbonatematerial, delivering superior light output Rated life Burning Hrs 50000 hr @Lumen Maintenanceof70%, maximumlightintensityshouldbebetween 60degrees to 70degrees. CCT Greater Than 5500K, IP66optical andelectrical compartment &impact resistanceof complete luminaire Greater Than IK08. Power Factor Greater Than 0.9 withmains,SurgeProtection-Min5KValongwithOver voltage/Overload, short circuit/miss-wiring protection. Compatibleforpolemountingwithouterdiaof40mmto 50mm.UniversalVoltagedriver tooperatewidevoltage range from100Vto 270V50/60Hz application. Compliance to IS 10322/IEC60598,LM79& LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site locationwith minimized minimal tools. LED Light fixture with ........WSystem Power consumption. LED Efficiency Greater Than 1301m/w, nominal CRI Greater Than75. Luminaire manufacturer should have in-house facilityaccredited by NABL/CPRI any Government certified agency & Design & Development facility certified by ISO9001:2008. Housingwith supplierwordmark/name shallbeEngraved /Embossing on thediecast housing/Bodypart.Warrantyof2Yearsagainstanymanufacturindefectworkingunderstandardelectricalconditionsas mentioned above should be given by LEDmanufacturer &Cree/Nichia/Lumileds/Osram make LED Source CSR Electrical SR-2023-24, ITEM NO:11.8.2, PAGE NO-46, 40 W LED STREETLIGHTNos4225.24225.28.0FalseNoneNoneFalseNoneFalse33801.60
3247713112375NoneMMH058Earthing: Providing and fixing and wiring earth electrode for grounding circuits IC cutouts and other equipments on the meter board in the pit. The pits should be filled up with equal proportion of salt and charcoal 150mm around the pipe to complete depth. The connection from the pipe to the conduits etc. is to established through GI wire of sizes as per clause 7.3.3 of IS 732 using 12mm bolts, nuts, washers and check nuts, the pipe shall have 16 through holes of 12mm dia. Volume - V Water supply SR 2023-24Job3937.53937.51.0FalseNoneNoneFalseNoneFalse3937.50
3247714112375NoneMMH059Supplying & Laying cable trays including welding, fixing of supports Cable tray of 300 mm width (suitable for cable duct of D type) VOL-6 KPTCL PG NO 120 . I no 22Mtr791.7791.750.0FalseNoneNoneFalseNoneFalse39585.00
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17177631520000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17177631520000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17177631520000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17177631520000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17177631520000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid Electrical License for executing building electrificatio works and should have executed similar electrical works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid license for executing water supply / sanitary engineering works and should have executed similar works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneTotal value of civl engineering works executed and payments received in the last five years (year-wise)NoneNone
NoneNoneNoneNoneList of existing commitments and ongoing worksNoneNone
NoneNoneNoneNoneList of works for which tenders already submittedNoneNone
NoneNoneNoneNoneBanker Details for referenceNoneNone
NoneNoneNoneNoneTo qualify for award of this contract, each tenderer in its name should have in the last five years i.e. 2019-20 to 2023-24 mandating satisfactory completed as a prime contractor for at least one similar work to an extent of Rs. 19.50 LakhsPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneRegistration Certificate issued by PWD officer not below the rank of chief EngineerCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNonePWD Registration Certificate (Class I/II/III/IV)
NoneNoneNoneNoneTo qualify for award of this contract, each tenderer in its name should have in the last five years i.e. 2019-20 to 2023-24 achieved in at least two financial years an average annual financial turnover in all classes of civil engineering construction works only of Rs 39.00 LakhsFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNoneGST CERTIFICATEFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneGST Registration
NoneNoneNoneNonePAN CERTIFICATEFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneITR Filed Copy (Mentioning PAN)
NoneNoneNoneNoneLiquid assets and or availability of credit facilities of not less than Rs 11.70 Lakhs in the form of Credit lines or Letters of Credit or Certificates from Banks for meeting the fund requirement Conditional bankers certificate not acceptableFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneLine of Credit
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Registration Certificate issued by PWD officer not below the rank of chief EngineerTrueTechnical Bid
To qualify for award of this contract, each tenderer in its name should have in the last five years i.e. 2019-20 to 2023-24 achieved in at least two financial years an average annual financial turnover in all classes of civil engineering construction works only of Rs 39.00 LakhsTrueTechnical Bid
To qualify for award of this contract, each tenderer in its name should have in the last five years i.e. 2019-20 to 2023-24 mandating satisfactory completed as a prime contractor for at least one similar work to an extent of Rs. 19.50 LakhsTrueTechnical Bid
Liquid assets and or availability of credit facilities of not less than Rs 11.70 Lakhs in the form of Credit lines or Letters of Credit or Certificates from Banks for meeting the fund requirement Conditional bankers certificate not acceptableTrueTechnical Bid
PAN CERTIFICATETrueTechnical Bid
GST CERTIFICATETrueTechnical Bid
tenderWorkLocationList
tenderSubEstimateNamedistrictNametaluqNameloksabhaContNameassemblyContNamelocationDescriptionlatitudeDegreeslatitudeMinuteslatitudeSecondslongitudeDegreeslongitudeMinuteslongitudeSeconds
Other WorksVijayanagaraHagaribommanahalliBellaryBELLARYHagaribommanahalliNoneNoneNoneNoneNoneNone
tenderAddressNone
tenderRecallDTONone