3134802 | 107764 | None | code01 | Demolishing R.C.C. work manually/ by mechanical means including stacking ofsteel bars and disposal of unserviceable material to theappropriate disposal area as per direction of Engineer-in-charge. Vol - 2 P-187/19.3 | Cum | 2668.6 | 2668.6 | 1.35 | False | None | None | False | None | False | 3602.61 | 0 |
3134803 | 107764 | None | code02 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge19.7.3 In cement mortar m3 1,029.00 Vol - 2 P-187/19.7.3 | Cum | 1131.9 | 1131.9 | 5.22 | False | None | None | False | None | False | 5908.518 | 0 |
3134804 | 107764 | None | code03 | 19.2.1 Demolishing cement concrete manually/ by mechanical means including disposal of material to the appropriate disposal area as per direction of Engineer-in-charge.m3 1,663.00Vol - 2 P-187/19.2.1 | Cum | 1829.3 | 1829.3 | 15.0 | False | None | None | False | None | False | 27439.5 | 0 |
3134805 | 107764 | None | code04 | Earth work excavation by manual means for drains,canals, waste eir,draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution ghts,removal of stumps and other deleterious matter,excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. Vol-01 P-5/1.4.1 In all kinds of soils Depth upto 1.5 m | Cum | 266.2 | 266.2 | 41.18 | False | None | None | False | None | False | 10962.116 | 0 |
3134806 | 107764 | None | code05 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse Vol-01 P-15/2.1.2 . | Cum | 6230.4 | 6230.4 | 5.06 | False | None | None | False | None | False | 31525.824 | 0 |
3134807 | 107764 | None | code06 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machinemixed with super plasticizers laid in finished layers, well compactedusing needle vibrators, including all lead & lifts, cost of all materials,quality confirming to the requirements of relevant IS codes , labour,Usage charges of machinery, curing and all the otherappurtenancesrequired to complete the work as per technical specifications. (The costof steel reinforcement to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse vol -1, P-15/2.2.2.1 aggregates. Including Form work for Columns. | Cum | 11987.71 | 11987.71 | 4.19 | False | None | None | False | None | False | 50228.5049 | 0 |
3134808 | 107764 | None | code07 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machinemixed with super plasticizers laid in finished layers, well compactedusing needle vibrators, including all lead & lifts, cost of all materials,quality confirming to the requirements of relevant IS codes , labour,Usage charges of machinery, curing and all the otherappurtenancesrequired to complete the work as per technical specifications. (The costof steel reinforcement to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse vol -1, P-15/2.2.2.1 aggregates. Including Form work for Beams and Lintels. | Cum | 11290.75 | 11290.75 | 8.04 | False | None | None | False | None | False | 90777.63 | 0 |
3134809 | 107764 | None | code08 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machinemixed with super plasticizers laid in finished layers, well compactedusing needle vibrators, including all lead & lifts, cost of all materials,quality confirming to the requirements of relevant IS codes , labour,Usage charges of machinery, curing and all the otherappurtenancesrequired to complete the work as per technical specifications. (The costof steel reinforcement to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse vol -1, P-15/2.2.2.1 aggregates. Including Form work for Roof Slab. | Cum | 10593.79 | 10593.79 | 15.71 | False | None | None | False | None | False | 166428.4409 | 0 |
3134810 | 107764 | None | code09 | 15.1 Polyurethane based Single Component for New Surface Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6 kg/m2 to achieve final DFT (Dry Film Thickness) of 1mm including prime coat of epoxy primer @150 g/m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification.m2 817.00 Vol-02 P-149 /15.1 | Sqm | 898.7 | 898.7 | 110.0 | False | None | None | False | None | False | 98857.0 | 0 |
3134811 | 107764 | None | code10 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machinemixed with super plasticizers laid in finished layers, well compactedusing needle vibrators, including all lead & lifts, cost of all materials,quality confirming to the requirements of relevant IS codes , labour,Usage charges of machinery, curing and all the otherappurtenancesrequired to complete the work as per technical specifications. (The costof steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse Vol - 1,P-15/2.2.2.1 aggregates. | Cum | 10245.31 | 10245.31 | 1.431 | False | None | None | False | None | False | 14661.03861 | 0 |
3134812 | 107764 | None | code11 | Providing and fixing Structural Steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting,hoisting, fixing in position and applying a priming coat of approved steel primer all complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Vol-02 P-77/11.2 | Kgs | 124.3 | 124.3 | 500.0 | False | None | None | False | None | False | 62150.0 | 0 |
3134813 | 107764 | None | code12 | 6.32 Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.m2 1,310.00Vol - 02 P-17/6.32 | Sqm | 1441.0 | 1441.0 | 108.03 | False | None | None | False | None | False | 155671.23 | 0 |
3134814 | 107764 | None | code13 | Providing Honne wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications.Vol-02 P-99/12.11 | Cum | 151881.4 | 151881.4 | 0.11 | False | None | None | False | None | False | 16706.954 | 0 |
3134815 | 107764 | None | code14 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 30 mm thick both side commercial. Vol-02 P-105/12.57.3 | Sqm | 3305.5 | 3305.5 | 4.41 | False | None | None | False | None | False | 14577.255 | 0 |
3134816 | 107764 | None | code15 | 11.34A Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding. Vol-02 P-86/11.34A | Kg | 184.8 | 184.8 | 280.77 | False | None | None | False | None | False | 51886.296 | 0 |
3134817 | 107764 | None | code16 | Providing and fixing of 3 track 2 panel sliding windows made out of multi chambered UPVC sections and with minimum TiO2 Titanium Dioxide at 6PHR with TPE Thermo Plastic Elastomer and lead free, gaskets grey colour having isolated drainage and reinforced with Galvanized Iron profile throughout the window frame. The outer frame having an overall size of 108mm width and 45mm height with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware, Multi point locking system with touch lock. Wall thickness of frame and sash shall be of 2-2.5mm. Maximum possible size -2419 mm x 2200 mm. The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made | Sqm | 7407.4 | 7407.4 | 13.37 | False | None | None | False | None | False | 99036.938 | 0 |
3134818 | 107764 | None | code17 | Providing Thermo-Mechanically Treated bars of grade Fe-500D ormore Steel reinforcement for R.C.C. work including straightening,cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (Thelaps and wastages shall not be measured separately) Volume- 2 ,Page 84/11.32. | Quintal | 10120.0 | 10120.0 | 32.13 | False | None | None | False | None | False | 325155.6 | 0 |
3134819 | 107764 | None | code18 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with ement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and olishing etc. all complete as specified and as directed by the Engineer-in- harge ** Polished Granite stone slab Black, Cherry Red, Brown, Cat eye, River Pink or equivalent.Vol-02 P-63/9.24. | Sqm | 3137.2 | 3137.2 | 4.02 | False | None | None | False | None | False | 12611.544 | 0 |
3134820 | 107764 | None | code19 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand),jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. completeSize of Tile 600x600 mm.Vol-02 P-61/9.17.2 | Sqm | 1292.5 | 1292.5 | 91.9 | False | None | None | False | None | False | 118780.75 | 0 |
3134821 | 107764 | None | code20 | Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per m2, including pointing in white cement mixed with pigment of matching shade complete.Vol-02 P-71/10.14 | Sqm | 1216.6 | 1216.6 | 14.1 | False | None | None | False | None | False | 17154.06 | 0 |
3134822 | 107764 | None | code21 | 8.9 Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Vol-02 P-42/8.9 | Sqm | 423.5 | 423.5 | 221.4 | False | None | None | False | None | False | 93762.9 | 0 |
3134823 | 107764 | None | code22 | 8.7 Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.m2 321.00 Vol-02 P-42/8.7 | Sqm | 402.6 | 402.6 | 126.0 | False | None | None | False | None | False | 50727.6 | 0 |
3134824 | 107764 | None | code23 | Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3
fine sand) on concrete surface / ceilings including rounding off corners
wherever required smooth rendering, providing and removing scaffolding,
including cost of materials, labour, curing complete as per specifications
and as per directions of Engineer-in-charge.Vol -02 P-43/8.10 | Sqm | 232.1 | 232.1 | 105.0 | False | None | None | False | None | False | 24370.5 | 0 |
3134825 | 107764 | None | code24 | 8.16 a Providing lath plaster with cement mortar 1:3, 5cms thick with 6mm dia mild steel bars at 20 cms. c to c both horizontally and vertically fixed with chicken mesh for drop chajja,facia, backing to cup boards including cost of all materials, labour, providing and removing form work usage charges,curing, complete as per specifications.Vol -02 P-44/8.16a | Sqm | 1361.8 | 1361.8 | 12.3 | False | None | None | False | None | False | 16750.14 | 0 |
3134826 | 107764 | None | code25 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.Vol-02 P-50/8.51 | Sqm | 110.0 | 110.0 | 250.0 | False | None | None | False | None | False | 27500.0 | 0 |
3134827 | 107764 | None | code26 | 8.32 Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. m2 112.00 Vol-02 P-46/8.32 | Sqm | 171.6 | 171.6 | 233.7 | False | None | None | False | None | False | 40102.92 | 0 |
3134828 | 107764 | None | code27 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Vol-02 P-43/8.41 | Sqm | 183.7 | 183.7 | 245.75 | False | None | None | False | None | False | 45144.275 | 0 |
3134829 | 107764 | None | code28 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Vol-02 P-48/8.40. | Sqm | 126.5 | 126.5 | 100.0 | False | None | None | False | None | False | 12650.0 | 0 |
3134830 | 107764 | None | code29 | 10.1 Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete For: Bwssb 10.1.7 PVC pipes 110mm dia., 6 kg/sqcm & class 3 m 411P-113 | Rmtr | 452.1 | 452.1 | 15.0 | False | None | None | False | None | False | 6781.5 | 0 |
3134831 | 107764 | None | code30 | 8.80 Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge:20 mm to 25 mm wide to required depth..Vol- 2 P-54/8.80 m 66.00 | Mtr | 72.6 | 72.6 | 200.0 | False | None | None | False | None | False | 14520.0 | 0 |
3134832 | 107764 | None | code31 | 13.34 Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. L 9.00 102/13.78.Vol- 2 P-123/14.1.1. | Ltr | 9.9 | 9.9 | 4000.0 | False | None | None | False | None | False | 39600.0 | 0 |
3134833 | 107764 | None | code32 | C16.9 Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.. Each 5454P- 191. | Nos | 5999.4 | 5999.4 | 1.0 | False | None | None | False | None | False | 5999.4 | 0 |
3134834 | 107764 | None | code33 | 2.51 Providing & fixing RCC Pre-cast Cover Slab of size 0.8 m x 0.8 m x 0.15m of M25-Design mix concrete with 12 mm steel @ 120 mm c/c both ways, over Gate valve extension spindle with central opening along with lid for smooth operation with appurtenances., complete with all lead and lifts etc. complete Each 2386 P- 33. | Each | 2624.6 | 2624.6 | 1.0 | False | None | None | False | None | False | 2624.6 | 0 |
3134835 | 107764 | None | code34 | 13.12 Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 No. 635.00 Vol-2/13.12 | No | 698.5 | 698.5 | 2.0 | False | None | None | False | None | False | 1397.0 | 0 |
3134836 | 107764 | None | code35 | 10.4 Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in Granite, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. each 591.00 Vol-2P-69/10.4 | Each | 650.1 | 650.1 | 2.0 | False | None | None | False | None | False | 1300.2 | 0 |
3134837 | 107764 | None | code36 | 14.9 Providing and fixing kitchen sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P. brass waste complete, including painting the fittings and brackets, cutting and making good the walls wherever required: 14.9.1 White glazed fire clay kitchen sink of size 600x450x 250 mm each 2,981.00 Vol-2P-133/14.9.1 | Each | 3279.1 | 3279.1 | 2.0 | False | None | None | False | None | False | 6558.2 | 0 |
3134838 | 107764 | None | code37 | 14.31 Providing and fixing 600x450 mm beveled edge mirror of superior glass
(of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. vol- 2 P-136/14.31. | Each | 1342.0 | 1342.0 | 2.0 | False | None | None | False | None | False | 2684.0 | 0 |
3134839 | 107764 | None | code38 | 14.40.2 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g. each 496.00 vol- 2 P-137/14.40.2 | Each | 545.6 | 545.6 | 2.0 | False | None | None | False | None | False | 1091.2 | 0 |
3134840 | 107764 | None | code39 | Providing and fixing 100 mm sand cast Iron grating for gully trap. vol- 2 P-136/14.29 | Each | 51.7 | 51.7 | 2.0 | False | None | None | False | None | False | 103.4 | 0 |
3134841 | 107764 | None | code40 | Providing and fixing Chorinated poly venyl chloride (CPVC) pipes conforming to IS 15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete. (concelaed work including cutting chases and making good walls) Vol-02 P-122/13.31.325mm dia | m | 349.8 | 349.8 | 25.0 | False | None | None | False | None | False | 8745.0 | 0 |
3134842 | 107764 | None | code41 | Providing and laying in position plain cement concrete for levelling course for all works in foundation The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed laid in layers not exceeding 150 mm thickness well compacted using plate vibrators including all lead and lifts cost of all materials of quality labour Usage charges of machineries curing and all the other appurtenances required to complete the work as per technical specifications The cost of steel reinforcement and formwork shall be paid separately Mix 124 Using 20 mm nominal size graded crushed coarse aggregates | Cum | 7121.4 | 7121.4 | 18.67 | False | None | None | False | None | False | 132956.538 | 0 |
3134843 | 107764 | None | code42 | Providing full nosing of 20 mm th granite slab using req machinery including and conveyance of all materials , labour for all items of work, Hom of equipments etc , complete P- 117/14.55 | Mtr | 278.34 | 278.34 | 5.5 | False | None | None | False | None | False | 1530.87 | 0 |
3134844 | 107764 | None | code43 | Disposal of building rubbish / malba / similar unserviceable, dismantledorwaste materials by mechanical means, including loading, transporting,unloading to approved municipal dumping ground or as approved byEngineer-in-charge to the appropriate disposal area.Vol- 2 P-193/19.59. | Cum | 400.4 | 400.4 | 55.0 | False | None | None | False | None | False | 22022.0 | 0 |
3134845 | 107764 | None | code44 | 13.59 Providing and fixing PVC (S.W.R) Nahani Trap 10cms x 10cms with all
fitting arrangements & all necessary accessories complete 1 Nahani
trap 220.00 | Cum | 242.0 | 242.0 | 2.0 | False | None | None | False | None | False | 484.0 | 0 |
3134846 | 107764 | None | code45 | 13.4 Providing and fixing Brass full way valve gate with C.I. wheel of
approved quality (screwed end) : 13.4.1 25 mm nominal bore No. 549.00 | No | 603.9 | 603.9 | 2.0 | False | None | None | False | None | False | 1207.8 | 0 |
3134847 | 107764 | None | code46 | Supplying and wiring adopting loop system in existing PVC Conduit / casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS 694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point upto 3Mtr from tapping point to out let via switch box 2.2.1 | No | 295.9 | 295.9 | 6.0 | False | None | None | False | None | False | 1775.4 | 0 |
3134848 | 107764 | None | code47 | Do- Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch box 2.2.2 | No | 416.9 | 416.9 | 10.0 | False | None | None | False | None | False | 4169.0 | 0 |
3134849 | 107764 | None | code48 | Do- Long point above 6Mtr upto 10Mtr from tapping point to out let via switch box 2.2.3 | No | 610.5 | 610.5 | 14.0 | False | None | None | False | None | False | 8547.0 | 0 |
3134850 | 107764 | None | code49 | Supplying heavy gauge PVC conduit pipe ...... mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire
wherever necessary 25 mm dia 2 mm thick 1.2.2 | Mtr | 85.8 | 85.8 | 80.0 | False | None | None | False | None | False | 6864.0 | 0 |
3134851 | 107764 | None | code50 | Supplying heavy gauge PVC Conduit Pipe .... dia ....... mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. 25 mm dia 2 mm thick 1.3.2 | Mtr | 75.89 | 75.89 | 30.0 | False | None | None | False | None | False | 2276.7 | 0 |
3134852 | 107764 | None | code51 | Open Conduit System: Supplying heavy gauge PVC conduit pipe ....... dia ....... mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. 19/20 mm dia 2 mm thick 1.1.1 | Mtr | 75.89 | 75.89 | 50.0 | False | None | None | False | None | False | 3794.5 | 0 |
3134853 | 107764 | None | code52 | Supplying and fixing of PVC casing and capping on the wall or ceiling using necessary materials like bends, junction box, elbows, screws at an interval of 300 mm as required. 25 mm 1.8.2 | Mtr | 38.49 | 38.49 | 10.0 | False | None | None | False | None | False | 384.9 | 0 |
3134854 | 107764 | None | code53 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS- 694:2010 1.5 mm2 2.3.2 | Mtr | 28.6 | 28.6 | 130.0 | False | None | None | False | None | False | 3718.0 | 0 |
3134855 | 107764 | None | code54 | Do- 2.5 mm2 2.3.3 | Mtr | 46.2 | 46.2 | 140.0 | False | None | None | False | None | False | 6468.0 | 0 |
3134856 | 107764 | None | code55 | Do- 4 mm2 2.3.4 | Mtr | 69.3 | 69.3 | 100.0 | False | None | None | False | None | False | 6930.0 | 0 |
3134857 | 107764 | None | code56 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 1-2 Way 3.3.1 | No | 113.3 | 113.3 | 2.0 | False | None | None | False | None | False | 226.6 | 0 |
3134858 | 107764 | None | code57 | Do- 3 Way 3.3.2 | No | 136.4 | 136.4 | 2.0 | False | None | None | False | None | False | 272.8 | 0 |
3134859 | 107764 | None | code58 | Do- 4-5 Way 3.3.3 | No | 150.7 | 150.7 | 2.0 | False | None | None | False | None | False | 301.4 | 0 |
3134860 | 107764 | None | code59 | Do- 6 Way 3.3.4 | No | 190.3 | 190.3 | 2.0 | False | None | None | False | None | False | 380.6 | 0 |
3134861 | 107764 | None | code60 | Do- 8 Way 3.3.5 | No | 240.9 | 240.9 | 8.0 | False | None | None | False | None | False | 1927.2 | 0 |
3134862 | 107764 | None | code61 | Do- 10-12 Way 3.3.6 | No | 287.1 | 287.1 | 8.0 | False | None | None | False | None | False | 2296.8 | 0 |
3134863 | 107764 | None | code62 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 1 to 2 Module 3.5.1 | No | 150.7 | 150.7 | 2.0 | False | None | None | False | None | False | 301.4 | 0 |
3134864 | 107764 | None | code63 | Do- 3 Module 3.5.2 | No | 177.1 | 177.1 | 2.0 | False | None | None | False | None | False | 354.2 | 0 |
3134865 | 107764 | None | code64 | Do- 4 Module 3.5.3 | No | 192.5 | 192.5 | 2.0 | False | None | None | False | None | False | 385.0 | 0 |
3134866 | 107764 | None | code65 | Do- 6 Module 3.5.4 | No | 257.4 | 257.4 | 10.0 | False | None | None | False | None | False | 2574.0 | 0 |
3134867 | 107764 | None | code66 | Do- 8 Module 3.5.5 | No | 312.4 | 312.4 | 10.0 | False | None | None | False | None | False | 3124.0 | 0 |
3134868 | 107764 | None | code67 | Do- 10-12 Module 3.5.6 | No | 378.4 | 378.4 | 8.0 | False | None | None | False | None | False | 3027.2 | 0 |
3134869 | 107764 | None | code68 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6A One Way Switch 3.6.1 | No | 112.2 | 112.2 | 40.0 | False | None | None | False | None | False | 4488.0 | 0 |
3134870 | 107764 | None | code69 | Do- 6A Three Way socket 3.6.3 | No | 188.1 | 188.1 | 25.0 | False | None | None | False | None | False | 4702.5 | 0 |
3134871 | 107764 | None | code70 | Do- Stepped Fan Regulator Two Module 3.6.4 | No | 392.7 | 392.7 | 6.0 | False | None | None | False | None | False | 2356.2 | 0 |
3134872 | 107764 | None | code71 | Do- 32A DP Switch 3.6.9 | No | 358.59 | 358.59 | 4.0 | False | None | None | False | None | False | 1434.36 | 0 |
3134873 | 107764 | None | code72 | Do- 6/16A Universal Socket 3.6.10 | No | 259.6 | 259.6 | 8.0 | False | None | None | False | None | False | 2076.8 | 0 |
3134874 | 107764 | None | code73 | Supplying of feet PVC Batten with integrated LED tube W with high quality diffuser with Life of 25000 burning hours 70 lumen maintenance with CRI 80 Power Input 220-240V 50/60Hz Power factor 0.9 along with CE approved 2 years Warranty against any manufacturing defect working under standard electrical condition LED light fitting 1 x 4ft - 20/22 W
| No | 759.0 | 759.0 | 10.0 | False | None | None | False | None | False | 7590.0 | 0 |
3134875 | 107764 | None | code74 | Do- LED light fitting 1 x 4' - 36/40 W 11.3.3 | No | 1395.9 | 1395.9 | 10.0 | False | None | None | False | None | False | 13959.0 | 0 |
3134876 | 107764 | None | code75 | Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling / rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clamps. 13.7 | No | 134.2 | 134.2 | 20.0 | False | None | None | False | None | False | 2684.0 | 0 |
3134877 | 107764 | None | code76 | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing
system. 48" Sweep (1200 mm) Regular model 6.3.1 | No | 3282.4 | 3282.4 | 10.0 | False | None | None | False | None | False | 32824.0 | 0 |
3134878 | 107764 | None | code77 | Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S'' hook with fan regulator to the existing board together with supplying and fixing 5 A. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring. 13.10 | No | 188.1 | 188.1 | 10.0 | False | None | None | False | None | False | 1881.0 | 0 |
3134879 | 107764 | None | code78 | Supplying of 1440rpm heavy duty exhaust fan with bracket blades
suitable to operate on 230V 50Hz, AC Supply complete. 12" Sweep (300 mm) 6.2.1 | No | 3265.9 | 3265.9 | 2.0 | False | None | None | False | None | False | 6531.8 | 0 |
3134880 | 107764 | None | code80 | Supply of 70 W LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr at Lumen Maintenance of 70 percentage, maximum light intensity should be between 60 degrees to 70 degrees. CCT greater 5500K, IP66 optical and electrical compartment & impact resistance of complete luminaire greater IK08. Power Factor greater 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED Efficiency greater 1301m/w, nominal CRI greater 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Streetlight 70W 11.8.3 | No | 6591.2 | 6591.2 | 6.0 | False | None | None | False | None | False | 39547.2 | 0 |
3134881 | 107764 | None | code79 | Fixing one exhaust fan in the nitch already left in the wall with bolts and nuts and 5 A. ceiling rose with sufficient length of 23/0.0076 inch PVC insulated twin core wire. 13.14 | No | 541.2 | 541.2 | 2.0 | False | None | None | False | None | False | 1082.4 | 0 |
3134882 | 107764 | None | code81 | Supplying and Fixing........mm dia clampsss A GI pipe bracket upto
2.7 meters long terminated with a reducing collar of 40x25mm to which extra pipe of 175mm length is fixed for fixing MV/SV/MH/FTL street light fitting of all capacities on rail/RCC/wall/tubular pole, using suitable clamps, bolts, nuts and wiring using suitable capacity wires. Using 32mm dia G.I.Pipe 13.2.2 | No | 1424.5 | 1424.5 | 6.0 | False | None | None | False | None | False | 8547.0 | 0 |
3134883 | 107764 | None | code82 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 A SP 5.18.1 | No | 456.5 | 456.5 | 4.0 | False | None | None | False | None | False | 1826.0 | 0 |
3134884 | 107764 | None | code83 | Do- 6-32 A DP 5.18.4 | No | 812.9 | 812.9 | 4.0 | False | None | None | False | None | False | 3251.6 | 0 |
3134885 | 107764 | None | code84 | Do- 6-32 A TPN 5.18.7 | No | 1888.7 | 1888.7 | 1.0 | False | None | None | False | None | False | 1888.7 | 0 |
3134886 | 107764 | None | code85 | Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure. II - Double Door 6 Way SP & N 5.19.7 | No | 1970.1 | 1970.1 | 1.0 | False | None | None | False | None | False | 1970.1 | 0 |
3134887 | 107764 | None | code86 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part- 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS- 3975 16 Sqmm, 4 Core, (11 GI Strips - 4 x 0.8 mm) 32.05 | Kms | 156026.2 | 156026.2 | 0.16 | False | None | None | False | None | False | 24964.192 | 0 |
3134888 | 107764 | None | code87 | Laying LTUG cable of 2.5 to 25 Sqmm (Single/3.5/4 Core) 20.05 | Kms | 1305.69 | 1305.69 | 0.16 | False | None | None | False | None | False | 208.9104 | 0 |
3134889 | 107764 | None | code88 | Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using
40 mm dia 2.90 mm thick GI pipe 2.5m long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150 mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12 mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia. 12.56 | No | 3861.0 | 3861.0 | 2.0 | False | None | None | False | None | False | 7722.0 | 0 |
3134890 | 107764 | None | code89 | Supply and fixing GI/Copper strips for grounding connections, using necessary fixing materials as required. 25 x 6 mm GI strip 12.58.3 | Mtr | 140.8 | 140.8 | 10.0 | False | None | None | False | None | False | 1408.0 | 0 |
3134891 | 107764 | None | code90 | Do- 600 x 600 x 3 mm Copper plate
12.58.11 | No | 8163.1 | 8163.1 | 2.0 | False | None | None | False | None | False | 16326.2 | 0 |
3134892 | 107764 | None | code91 | Supplying And fixing/replacing of 6/16/32A electrical
accessories on existing switch board. 6A Batten Holder 3.14.7 | No | 81.4 | 81.4 | 4.0 | False | None | None | False | None | False | 325.6 | 0 |
3134893 | 107764 | None | code92 | Do- 6A Bakelite Ceiling Rose 3.14.5 | No | 85.8 | 85.8 | 2.0 | False | None | None | False | None | False | 171.6 | 0 |