3263270 | 113032 | None | code01 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)--M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 12459.05 | 12459.05 | 11.66 | False | None | None | False | None | False | 145272.523 | 0 |
3263271 | 113032 | None | code02 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)-- Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse
aggregates | Cum | 17973.14 | 17973.14 | 5.4 | False | None | None | False | None | False | 97054.956 | 0 |
3263272 | 113032 | None | code03 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)--M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 11726.16 | 11726.16 | 7.04 | False | None | None | False | None | False | 82552.1664 | 0 |
3263273 | 113032 | None | code04 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)--M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 11726.16 | 11726.16 | 2.41 | False | None | None | False | None | False | 28260.0456 | 0 |
3263274 | 113032 | None | code05 | Providing and constructing load bearing wall with Solid
Concrete blocks of size 400x200x200mm having block density
more than 1800kg/m3 and minimum compressive strength of
4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and
constructed with CM 1:4 as per IS 2572:2005 including cost of
all materials, labour, scaffolding and curing, usage charges of
machinery etc complete as per specifications ISSUED RATE-1196 | Sqm | 1403.01 | 1403.01 | 369.9213 | False | None | None | False | None | False | 519003.283113 | 0 |
3263275 | 113032 | None | code06 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. | Sqm | 1318.4 | 1318.4 | 292.44 | False | None | None | False | None | False | 385552.896 | 0 |
3263276 | 113032 | None | code07 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)--M25 Design Mix Using 20 mm nominal size graded crushed coarse
aggregates | Cum | 10993.28 | 10993.28 | 49.27 | False | None | None | False | None | False | 541638.9056 | 0 |
3263277 | 113032 | None | code08 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)--M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 10626.84 | 10626.84 | 2.09 | False | None | None | False | None | False | 22210.0956 | 0 |
3263278 | 113032 | None | code09 | Providing Thermo-Mechanically Treated bars of grade Fe-550D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) | Kg | 89.45 | 89.45 | 11132.26 | False | None | None | False | None | False | 995780.657 | 0 |
3263279 | 113032 | None | code10 | Providing Red Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. | Cum | 106671.46 | 106671.46 | 0.09 | False | None | None | False | None | False | 9600.4314 | 0 |
3263280 | 113032 | None | code11 | Providing & fixing of 2.5 track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets grey colour having isolated drainage and reinforced with Galvanized Iron profile through out the window frame. The outer frame having an overall size of 94mm width x 45mm height with reinforcement of 1mm thickness and Sash with overall size of 39mm x 58mm with Greinforcement of 1.5mm and mesh sash of size 25mm x 42mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 1819mm x 1819mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) | Sqm | 7016.12 | 7016.12 | 72.9 | False | None | None | False | None | False | 511475.148 | 0 |
3263281 | 113032 | None | code12 | Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) | Sqm | 6125.05 | 6125.05 | 7.17 | False | None | None | False | None | False | 43916.6085 | 0 |
3263282 | 113032 | None | code13 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification.-35 mm thick both side commercial | Sqm | 3557.86 | 3557.86 | 24.0 | False | None | None | False | None | False | 85388.64 | 0 |
3263283 | 113032 | None | code14 | Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges. -do- with both side prelam | Sqm | 2584.67 | 2584.67 | 21.6 | False | None | None | False | None | False | 55828.872 | 0 |
3263284 | 113032 | None | code15 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding. | Kg | 179.93 | 179.93 | 1681.47 | False | None | None | False | None | False | 302546.8971 | 0 |
3263285 | 113032 | None | code16 | Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. | No | 128.52 | 128.52 | 10.0 | False | None | None | False | None | False | 1285.2 | 0 |
3263286 | 113032 | None | code17 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. | No | 1126.69 | 1126.69 | 10.0 | False | None | None | False | None | False | 11266.9 | 0 |
3263287 | 113032 | None | code18 | Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. complete. | No | 253.83 | 253.83 | 20.0 | False | None | None | False | None | False | 5076.6 | 0 |
3263288 | 113032 | None | code19 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete. | No | 139.23 | 139.23 | 30.0 | False | None | None | False | None | False | 4176.9 | 0 |
3263289 | 113032 | None | code20 | Providing and fixing ISI marked M.S. pressed butt hinges bright finished with necessary screws etc.-125x65x2.12mm. | No | 58.91 | 58.91 | 40.0 | False | None | None | False | None | False | 2356.4 | 0 |
3263290 | 113032 | None | code21 | Providing and fixing MS Hold fasts | No | 53.55 | 53.55 | 40.0 | False | None | None | False | None | False | 2142.0 | 0 |
3263291 | 113032 | None | code22 | Providing 12 mm cement plaster with Cement mortar 1:3 (1cement: 3 coarse sand) finished with a floating coat of neat cement to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete | Sqm | 345.93 | 345.93 | 297.01 | False | None | None | False | None | False | 102744.6693 | 0 |
3263292 | 113032 | None | code23 | Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 391.99 | 391.99 | 1211.82 | False | None | None | False | None | False | 475021.3218 | 0 |
3263293 | 113032 | None | code24 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 315.95 | 315.95 | 141.36 | False | None | None | False | None | False | 44662.692 | 0 |
3263294 | 113032 | None | code25 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 412.34 | 412.34 | 747.36 | False | None | None | False | None | False | 308166.4224 | 0 |
3263295 | 113032 | None | code26 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)-- Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse
aggregates | Cum | 6658.41 | 6658.41 | 31.87 | False | None | None | False | None | False | 212203.5267 | 0 |
3263296 | 113032 | None | code27 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)--M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Sqm | 7400.7 | 7400.7 | 22.33 | False | None | None | False | None | False | 165257.631 | 0 |
3263297 | 113032 | None | code28 | Providing and laying cinder concrete in cement 1:15 (1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications. | Cum | 2160.21 | 2160.21 | 1.39 | False | None | None | False | None | False | 3002.6919 | 0 |
3263298 | 113032 | None | code29 | Providing and laying Granite tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.-- Size of Tile (600X600) mm | Sqm | 2641.09 | 2641.09 | 16.92 | False | None | None | False | None | False | 44687.2428 | 0 |
3263299 | 113032 | None | code30 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.-- Size of Tile (600X600) mm | Sqm | 1226.3 | 1226.3 | 194.51 | False | None | None | False | None | False | 238527.613 | 0 |
3263300 | 113032 | None | code31 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete | Sqm | 952.12 | 952.12 | 64.74 | False | None | None | False | None | False | 61640.2488 | 0 |
3263301 | 113032 | None | code32 | Providing and laying Polished Sadarahalli Grey Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building, all complete as per architectural drawings with 20mm thick stone slab over 20mm (average) thick base of concrete mortar 1:4(1 cement:4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc all complete as specified and as directed by the Enginner-in-charge. | Sqm | 2233.04 | 2233.04 | 13.3 | False | None | None | False | None | False | 29699.432 | 0 |
3263302 | 113032 | None | code33 | Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per m2, including pointing in white cement mixed with pigment of matching shade complete. | Sqm | 1184.53 | 1184.53 | 141.36 | False | None | None | False | None | False | 167445.1608 | 0 |
3263303 | 113032 | None | code34 | Providing and laying flooring and steps machine cut granite slabs 40 mm thick on cement mortar bed 1:6, 25 mm thick, and pointed with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar labour, curing complete as per specifications. | Sqm | 4582.81 | 4582.81 | 4.08 | False | None | None | False | None | False | 18697.8648 | 0 |
3263304 | 113032 | None | code35 | Providing and applying white cement based putty of average
thickness 1 mm, of approved brand and manufacturer, over the
plastered wall surface to prepare the surface even and smooth
complete as per specifications and as per directions of
Engineer in charge. | Sqm | 107.1 | 107.1 | 1508.83 | False | None | None | False | None | False | 161595.693 | 0 |
3263305 | 113032 | None | code36 | Finishing with Deluxe Multi surface paint system for interiors andexteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Specialprimer applied @ 0.75 ltr /10 m² with paint of approved quality to givean even shade, after thoroughly brooming the surface to remove all dirt,dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 169.22 | 169.22 | 297.01 | False | None | None | False | None | False | 50260.0322 | 0 |
3263306 | 113032 | None | code37 | Finishing with Deluxe Multi surface paint system for interiors andexteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Specialprimer applied @ 0.75 ltr /10 m² with paint of approved quality to givean even shade, after thoroughly brooming the surface to remove all dirt,dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 170.88 | 170.88 | 29.7 | False | None | None | False | None | False | 5075.136 | 0 |
3263307 | 113032 | None | code38 | Finishing with Deluxe Multi surface paint system for interiors andexteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Specialprimer applied @ 0.75 ltr /10 m² with paint of approved quality to givean even shade, after thoroughly brooming the surface to remove all dirt,dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 169.22 | 169.22 | 1211.82 | False | None | None | False | None | False | 205064.1804 | 0 |
3263308 | 113032 | None | code39 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 186.35 | 186.35 | 817.59 | False | None | None | False | None | False | 152357.8965 | 0 |
3263309 | 113032 | None | code40 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 188.18 | 188.18 | 36.76 | False | None | None | False | None | False | 6917.4968 | 0 |
3263310 | 113032 | None | code41 | Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper
smooth, cost of materials, labour complete as per specifications and as
per directions of Engineer-in-charge. | Sqm | 303.09 | 303.09 | 91.9 | False | None | None | False | None | False | 27853.971 | 0 |
3263311 | 113032 | None | code42 | Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper
smooth, cost of materials, labour complete as per specifications and as
per directions of Engineer-in-charge. | Sqm | 306.06 | 306.06 | 9.19 | False | None | None | False | None | False | 2812.6914 | 0 |
3263312 | 113032 | None | code43 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @ 0.80 ltr/10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as
per directions of Engineer-in-charge | Sqm | 144.59 | 144.59 | 61.39 | False | None | None | False | None | False | 8876.3801 | 0 |
3263313 | 113032 | None | code44 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/ litre as per specifications and as per directions of Engineer in charge. | Sqm | 59.98 | 59.98 | 21.6 | False | None | None | False | None | False | 1295.568 | 0 |
3263314 | 113032 | None | code45 | Polishing on wood work with ready mixed wax polish of approved brand and manufacture : New work to give an even surface including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 144.59 | 144.59 | 21.6 | False | None | None | False | None | False | 3123.144 | 0 |
3263315 | 113032 | None | code46 | Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for:-PVC pipes 110mm dia., 6 kg/sqcm & class 3 | Mtr | 440.18 | 440.18 | 25.9 | False | None | None | False | None | False | 11400.662 | 0 |
3263316 | 113032 | None | code47 | Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge. | Sqm | 875.01 | 875.01 | 8.97 | False | None | None | False | None | False | 7848.8397 | 0 |
3263317 | 113032 | None | code48 | Providing and fixing plaster mesh 200mm wide manufactured out of hot dipped galvanized iron of nominal thickness 0.35mm with a zinc coating of 120gms per Sqm width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. (length of mesh only be measured for payment) | Mtr | 47.12 | 47.12 | 300.46 | False | None | None | False | None | False | 14157.6752 | 0 |
3263318 | 113032 | None | code49 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required-White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests | Nos | 5231.0 | 5231.0 | 5.0 | False | None | None | False | None | False | 26155.0 | 0 |
3263319 | 113032 | None | code50 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid | Nos | 6401.0 | 6401.0 | 1.0 | False | None | None | False | None | False | 6401.0 | 0 |
3263320 | 113032 | None | code51 | Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required: using White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer | Nos | 3069.0 | 3069.0 | 6.0 | False | None | None | False | None | False | 18414.0 | 0 |
3263321 | 113032 | None | code52 | Providing and fixing 100 mm sand cast Iron grating for gully trap. | Nos | 50.0 | 50.0 | 17.0 | False | None | None | False | None | False | 850.0 | 0 |
3263322 | 113032 | None | code53 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. | Nos | 776.0 | 776.0 | 17.0 | False | None | None | False | None | False | 13192.0 | 0 |
3263323 | 113032 | None | code54 | Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) 25 mm nominal bore | Nos | 588.0 | 588.0 | 12.0 | False | None | None | False | None | False | 7056.0 | 0 |
3263324 | 113032 | None | code55 | Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) 32 mm nominal bore | Nos | 640.0 | 640.0 | 8.0 | False | None | None | False | None | False | 5120.0 | 0 |
3263325 | 113032 | None | code56 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. | Nos | 1281.0 | 1281.0 | 6.0 | False | None | None | False | None | False | 7686.0 | 0 |
3263326 | 113032 | None | code57 | 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g. | No | 531.0 | 531.0 | 6.0 | False | None | None | False | None | False | 3186.0 | 0 |
3263327 | 113032 | None | code58 | Providing and fixing Chorinated Poly Venly Cloride (CPVC) pipes conforming to IS15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr. spacing. This includes jointing of pipes and fitting with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete. (concealed work including cutting chases and good the walls etc), For 50 mm dia | m | 836.0 | 836.0 | 40.0 | False | None | None | False | None | False | 33440.0 | 0 |
3263328 | 113032 | None | code59 | Providing and fixing Chorinated Poly Venly Cloride (CPVC) pipes conforming to IS15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr. spacing. This includes jointing of pipes and fitting with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete. (concealed work including cutting chases and good the walls etc), For 32 mm dia | m | 428.0 | 428.0 | 45.0 | False | None | None | False | None | False | 19260.0 | 0 |
3263329 | 113032 | None | code60 | Providing and fixing Chorinated Poly Venly Cloride (CPVC) pipes conforming to IS15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr. spacing. This includes jointing of pipes and fitting with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete. (concealed work including cutting chases and good the walls etc), For 25 mm dia | m | 341.0 | 341.0 | 50.0 | False | None | None | False | None | False | 17050.0 | 0 |
3263330 | 113032 | None | code61 | Providing and fixing Chorinated Poly Venly Cloride (CPVC) pipes conforming to IS15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr. spacing. This includes jointing of pipes and fitting with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete. (concealed work including cutting chases and good the walls etc), For 20 mm dia | Nos | 259.0 | 259.0 | 5.0 | False | None | None | False | None | False | 1295.0 | 0 |
3263331 | 113032 | None | code62 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work- In all kinds of soils Depth upto 3 m-Hard soil | Cum | 107.1 | 107.1 | 54.49 | False | None | None | False | None | False | 5835.879 | 0 |
3263332 | 113032 | None | code63 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work- In all kinds of soils Depth upto 3 m-Soft rock | Cum | 381.15 | 381.15 | 36.33 | False | None | None | False | None | False | 13847.1795 | 0 |
3263333 | 113032 | None | code64 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fineaggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)-Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates | Cum | 5947.2 | 5947.2 | 12.4 | False | None | None | False | None | False | 73745.28 | 0 |
3263334 | 113032 | None | code65 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately)-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 8% ON CONCRETE ITEM) | Cum | 7129.46 | 7129.46 | 7.09 | False | None | None | False | None | False | 50547.8714 | 0 |
3263335 | 113032 | None | code66 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other---- M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 50% ON CONCRETE ITEM) | Cum | 9979.2 | 9979.2 | 20.52 | False | None | None | False | None | False | 204773.184 | 0 |
3263336 | 113032 | None | code67 | Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. | Cum | 497.7 | 497.7 | 30.33 | False | None | None | False | None | False | 15095.241 | 0 |
3263337 | 113032 | None | code68 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)-- M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 70% ON CONCRETE ITEM) | Cum | 12214.76 | 12214.76 | 7.04 | False | None | None | False | None | False | 85991.9104 | 0 |
3263338 | 113032 | None | code69 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)-- Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 60% ON CONCRETE ITEM) | Cum | 9465.38 | 9465.38 | 2.07 | False | None | None | False | None | False | 19593.3366 | 0 |
3263339 | 113032 | None | code70 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 471.45 | 471.45 | 648.0 | False | None | None | False | None | False | 305499.6 | 0 |
3263340 | 113032 | None | code71 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in charge. | Sqm | 182.7 | 182.7 | 648.0 | False | None | None | False | None | False | 118389.6 | 0 |
3263341 | 113032 | None | code72 | Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : vol- 2 Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 5891.55 | 5891.55 | 49.0 | False | None | None | False | None | False | 288685.95 | 0 |
3263342 | 113032 | None | code73 | Providing and fixing concertina coil fencing with punched tape concertina coil 600 mm dia 10 metre openable length ( total length 90 m), having 50 nos rounds per 6 metre length, upto 3 m height of wall with existing angle iron 'Y' shaped placed 2.4m or 3.00 m apart and with 9 horizontal R.B.T. reinforced barbed wire, stud tied with G.I. staples and G.I. clips to retain horizontal, including necessary bolts or G.I. barbed wire tied to angle iron, all complete as per direction of Engineer-in-charge, with reinforced barbed tape(R.B.T.) / Spring core (2.5mm thick) wire of high tensile strength of 165 kg/mm2 with tape (0.52 mm thick) and weight 43.478 g/m | Mtr | 331.8 | 331.8 | 125.0 | False | None | None | False | None | False | 41475.0 | 0 |
3263343 | 113032 | None | code74 | Supplying at site Angle iron post & strut of required size including bottom to be split and bent at right angle in opposite direction for 10 cm length and drilling holes upto 10 mm dia. etc. complete.-Y-Angle-ISA,50mmx50mmx3mm | Kg | 118.65 | 118.65 | 27.0 | False | None | None | False | None | False | 3203.55 | 0 |
3263344 | 113032 | None | code75 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding | Kg | 176.4 | 176.4 | 168.0 | False | None | None | False | None | False | 29635.2 | 0 |
3263345 | 113032 | None | code76 | Granular Sub-Base Plant Mix Method Construction of Granular Sub-Base of required grading as per design mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per clause 401 For Grading -I Material | Cum | 2612.4 | 2612.4 | 12.0 | False | None | None | False | None | False | 31348.8 | 0 |
3263346 | 113032 | None | code77 | Supplying and fixing M15 grade precast cement concrete Kerb stones for Roadway, Sidewalls and gutters fixed with CM 1:3 fixed and finsihed in line as per direction of Engineer in charge.
(The cost of PCC shall be paid extra) 600 x 300 x 150 mm Kerb Stone | Mtr | 486.15 | 486.15 | 200.0 | False | None | None | False | None | False | 97230.0 | 0 |
3263347 | 113032 | None | code78 | Providing and laying 60mm thick factory made precast M -30 grade Cement Concrete Paver Block as per IRC SP 63:2018 & IS 15658 for Cycle Tracks & Pedestrian Footpaths of approved shape and colour, laid in required pattern and including over 30mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-incharge. (WMM/WBM Base to be paid separately if necessary as per relevant technical specification) | Sqm | 1121.4 | 1121.4 | 120.0 | False | None | None | False | None | False | 134568.0 | 0 |
3263348 | 113032 | None | code79 | Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest
amendments and conveying to worksite, rolling and lowering into
trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: PVC pipes 110mm dia., 6 kg/sqcm & class 3 | Mtr | 431.55 | 431.55 | 220.0 | False | None | None | False | None | False | 94941.0 | 0 |
3263349 | 113032 | None | code80 | Constructing brick masonry chamber of internal dimension 450x450mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding excluding the cost of CI frame and cover.. | No | 4447.8 | 4447.8 | 8.0 | False | None | None | False | None | False | 35582.4 | 0 |
3263350 | 113032 | None | code81 | Providing and fixing SFRC frame and cover conforming to IS 12592 (part-I)-1988 and IS 12592 (part-II)- 1991 with latest amendment, including cutting slabs to the required size for the opening and fixing the cover in C.C. 1:2:4 and C.M. 1:3 plastering 20 mm thick to all exposed faces, curing for 10 days with all lead and lift with appurtenances.
complete. | No | 2009.7 | 2009.7 | 7.0 | False | None | None | False | None | False | 14067.9 | 0 |
3263351 | 113032 | None | code82 | Earth work excavation for pipeline trenches in all kinds of soils by mechanical means above 600 mm trench width as per drawing and technical specifications, including setting out, construction of shoring, strutting, barricading, caution lights, bracing, using sight rails & boning rods at every 100 mm whevere necessary as directed, removal of stumps and other deleterious matter, dressing of sides and levelling the bottom of trench to the extent required , utilising the available excavated earth locally for the work etc., and all other appurtenances complete in the following strata.-for sinking 1200mm dia RCC ring 2500mm deep | Cum | 275.1 | 275.1 | 4.42 | False | None | None | False | None | False | 1215.942 | 0 |
3263352 | 113032 | None | code83 | Supplying to work spot rolling, lowering and placing in position RCC
perforated rings in the already excavated pit including loading and
unloading at both the destinations with all lead and lift with appurtenances., complete.-1200mmdia 1250mm height | No | 10021.2 | 10021.2 | 2.0 | False | None | None | False | None | False | 20042.4 | 0 |
3263353 | 113032 | None | code84 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates | Cum | 5947.2 | 5947.2 | 0.2 | False | None | None | False | None | False | 1189.44 | 0 |
3263354 | 113032 | None | code85 | Aggregate filling-Using 40 mm nominal size
graded crushed coarse aggregates Details of cost for 1 m3
MATERIAL Stone Aggregate (Single size) :40 mm nominal size | Cum | 1249.0 | 1249.0 | 1.7 | False | None | None | False | None | False | 2123.3 | 0 |
3263355 | 113032 | None | code86 | Mix 1:5:10 (M 5.0) Using 40 mm nominal size graded crushed coarse aggregates Details of cost for 1 m3 MATERIAL Coarse sand | Cum | 1549.8 | 1549.8 | 1.13 | False | None | None | False | None | False | 1751.274 | 0 |
3263356 | 113032 | None | code87 | Providing & fixing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete as per design drawings (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required as per the direction of Engineer in charge. | Sqm | 950.64 | 950.64 | 390.0 | False | None | None | False | None | False | 370749.6 | 0 |
3263357 | 113032 | None | code88 | Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top co | Mtr | 1161.53 | 1161.53 | 86.4 | False | None | None | False | None | False | 100356.192 | 0 |
3263358 | 113032 | None | code89 | Providing and fixing Structural Steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in- Charge.-ISMC/ISMB/ISA150*75*5.7mm | Kg | 122.21 | 122.21 | 1460.25 | False | None | None | False | None | False | 178457.1525 | 0 |
3263359 | 113032 | None | code90 | Supplying at site Angle iron post & strut of required size including bottom to be split and bent at right angle in opposite direction for 10 cm length and drilling holes upto 10 mm dia. etc. complete.-ISA Angle50mmx50mmx6mm | Kg | 122.21 | 122.21 | 9937.5 | False | None | None | False | None | False | 1214461.875 | 0 |
3263360 | 113032 | None | code91 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.-short point upto 3 mtr from tapping point to outlet via switch. | Point | 282.45 | 282.45 | 13.0 | False | None | None | False | None | False | 3671.85 | 0 |
3263361 | 113032 | None | code92 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Medium point above 3Mtr up to 6Mtr from tapping point to out let via switch | Point | 397.95 | 397.95 | 25.0 | False | None | None | False | None | False | 9948.75 | 0 |
3263362 | 113032 | None | code93 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Long point above 6Mtr up to 10Mtr from tapping point to out let via switch | Point | 582.75 | 582.75 | 100.0 | False | None | None | False | None | False | 58275.0 | 0 |
3263363 | 113032 | None | code94 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Two outlet in a row, above 3Mtr up to 6Mtr from tapping point to out let via switches | Point | 710.85 | 710.85 | 20.0 | False | None | None | False | None | False | 14217.0 | 0 |
3263364 | 113032 | None | code95 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Three outlet in a row, above 6Mtr up to 10Mtr from tapping point to out let via switches | Point | 1038.45 | 1038.45 | 6.0 | False | None | None | False | None | False | 6230.7 | 0 |
3263365 | 113032 | None | code96 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 3Way | Each | 166.95 | 166.95 | 183.0 | False | None | None | False | None | False | 30551.85 | 0 |
3263366 | 113032 | None | code97 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 6Way | Each | 231.0 | 231.0 | 50.0 | False | None | None | False | None | False | 11550.0 | 0 |
3263367 | 113032 | None | code98 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 10-12Way | Each | 334.95 | 334.95 | 30.0 | False | None | None | False | None | False | 10048.5 | 0 |
3263368 | 113032 | None | code99 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 3 Module | Each | 169.05 | 169.05 | 183.0 | False | None | None | False | None | False | 30936.15 | 0 |
3263369 | 113032 | None | code100 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 6 Module | Each | 245.7 | 245.7 | 50.0 | False | None | None | False | None | False | 12285.0 | 0 |
3263370 | 113032 | None | code101 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 10 to 12 Module | Each | 274.05 | 274.05 | 30.0 | False | None | None | False | None | False | 8221.5 | 0 |
3263371 | 113032 | None | code102 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps one way Switch | Each | 107.1 | 107.1 | 400.0 | False | None | None | False | None | False | 42840.0 | 0 |
3263372 | 113032 | None | code103 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps Two way Switch | Each | 174.3 | 174.3 | 10.0 | False | None | None | False | None | False | 1743.0 | 0 |
3263373 | 113032 | None | code104 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps 3way socket | Each | 179.55 | 179.55 | 200.0 | False | None | None | False | None | False | 35910.0 | 0 |
3263374 | 113032 | None | code105 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Stepped Fan Regulator. | Each | 374.85 | 374.85 | 45.0 | False | None | None | False | None | False | 16868.25 | 0 |
3263375 | 113032 | None | code106 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 16Amps one way switch | Each | 189.0 | 189.0 | 20.0 | False | None | None | False | None | False | 3780.0 | 0 |
3263376 | 113032 | None | code107 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 32Amps DP switch | Each | 393.75 | 393.75 | 5.0 | False | None | None | False | None | False | 1968.75 | 0 |
3263377 | 113032 | None | code108 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6/16Amps universal socket | Each | 247.8 | 247.8 | 50.0 | False | None | None | False | None | False | 12390.0 | 0 |
3263378 | 113032 | None | code109 | Supplying and fixing of Metal Socket set of 2pole and earth plugs and socket for incorporating SP and TP MCB (Without MCB).The entire plug and socket shall be mounted in a thermoplastic I powder coated metal box & wired Completely. 20 A | Each | 916.65 | 916.65 | 2.0 | False | None | None | False | None | False | 1833.3 | 0 |
3263379 | 113032 | None | code110 | Supplying and fixing of MODULAR MCB Devices(Tripper) With Breaking capacity of 6KA. 16 - 32 A SP | Each | 199.5 | 199.5 | 2.0 | False | None | None | False | None | False | 399.0 | 0 |
3263380 | 113032 | None | code111 | Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 19/20mm dia 2mm thick | Mtr | 69.3 | 69.3 | 3500.0 | False | None | None | False | None | False | 242550.0 | 0 |
3263381 | 113032 | None | code112 | Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 25mm dia 2mm thick | Mtr | 81.9 | 81.9 | 150.0 | False | None | None | False | None | False | 12285.0 | 0 |
3263382 | 113032 | None | code113 | Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 32mm dia 2.5mm thick | Mtr | 108.15 | 108.15 | 50.0 | False | None | None | False | None | False | 5407.5 | 0 |
3263383 | 113032 | None | code114 | Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 19/20mm dia 2mm thick | Mtr | 71.4 | 71.4 | 1000.0 | False | None | None | False | None | False | 71400.0 | 0 |
3263384 | 113032 | None | code115 | Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 25mm dia 2mm thick | Mtr | 82.95 | 82.95 | 500.0 | False | None | None | False | None | False | 41475.0 | 0 |
3263385 | 113032 | None | code116 | Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 32mm dia 2.5mm thick | Mtr | 103.95 | 103.95 | 25.0 | False | None | None | False | None | False | 2598.75 | 0 |
3263386 | 113032 | None | code117 | Supplying and fixing PVC/metal conduit Deep junction box 25mm deep junction box | No | 58.8 | 58.8 | 130.0 | False | None | None | False | None | False | 7644.0 | 0 |
3263387 | 113032 | None | code118 | Supplying and fixing PVC/metal conduit Deep junction box 32 mm deep junction box | No | 64.05 | 64.05 | 40.0 | False | None | None | False | None | False | 2562.0 | 0 |
3263388 | 113032 | None | code119 | Supplying And Fixing Metal Fan Box with Round Hook. | No | 122.85 | 122.85 | 100.0 | False | None | None | False | None | False | 12285.0 | 0 |
3263389 | 113032 | None | code120 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest
amendments. 1.5 sqmm | Mtr | 27.3 | 27.3 | 2200.0 | False | None | None | False | None | False | 60060.0 | 0 |
3263390 | 113032 | None | code121 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest
amendments. 2.5 sqmm | Mtr | 44.1 | 44.1 | 2500.0 | False | None | None | False | None | False | 110250.0 | 0 |
3263391 | 113032 | None | code122 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest
amendments. 4 sqmm | Mtr | 66.15 | 66.15 | 500.0 | False | None | None | False | None | False | 33075.0 | 0 |
3263392 | 113032 | None | code123 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest
amendments. 6 sqmm | Mtr | 96.6 | 96.6 | 900.0 | False | None | None | False | None | False | 86940.0 | 0 |
3263393 | 113032 | None | code124 | Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure-8waySPN | Each | 1946.7 | 1946.7 | 2.0 | False | None | None | False | None | False | 3893.4 | 0 |
3263394 | 113032 | None | code125 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32Amps SP | Each | 435.75 | 435.75 | 22.0 | False | None | None | False | None | False | 9586.5 | 0 |
3263395 | 113032 | None | code126 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32Amps DP | Each | 775.95 | 775.95 | 2.0 | False | None | None | False | None | False | 1551.9 | 0 |
3263396 | 113032 | None | code127 | Supplying, fixing and wiring Residential Circuit Breaker [RCCB] 240/450V up to 300mA sensitivity on existing wood/panel board-16A-25A 2 Pole | Each | 4490.85 | 4490.85 | 2.0 | False | None | None | False | None | False | 8981.7 | 0 |
3263397 | 113032 | None | code128 | Supplying of ......feet - PVC Batten with integrated LED tube .....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.-LED light fighting 1x4'-20/22w | Each | 724.5 | 724.5 | 65.0 | False | None | None | False | None | False | 47092.5 | 0 |
3263398 | 113032 | None | code129 | Supplying & fixing of retrofit type - LED bulb.......W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70%. efficacy 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.-12 W6500k | Each | 282.45 | 282.45 | 2.0 | False | None | None | False | None | False | 564.9 | 0 |
3263399 | 113032 | None | code130 | Supplying exhaust fan of 1440 RPM of 300mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply. | Each | 1566.6 | 1566.6 | 8.0 | False | None | None | False | None | False | 12532.8 | 0 |
3263400 | 113032 | None | code131 | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system.48"sweep(1200mm) Regular model | Each | 3133.2 | 3133.2 | 47.0 | False | None | None | False | None | False | 147260.4 | 0 |
3263401 | 113032 | None | code132 | Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S'' hook with fan regulator to the existing board together with supplying and fixing 5 A. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring. | Each | 179.55 | 179.55 | 45.0 | False | None | None | False | None | False | 8079.75 | 0 |
3263402 | 113032 | None | code133 | Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps.-on wall/ceiling/rafter/girders | Each | 128.1 | 128.1 | 62.0 | False | None | None | False | None | False | 7942.2 | 0 |
3263403 | 113032 | None | code134 | Supplying & laying of of 11 kV, 3 Core, XPLE HTUG Cable with pressure extruded inner sheeth, ROUND WIRE ARMOURED as per IS-7098 (Part-2)Armouring wires dia and Resistivity as per
IS-3975-95 sqmm, ( 54 GI Wires-2.5mm dia) | Km | 1160899.0 | 1160899.0 | 0.34 | False | None | None | False | None | False | 394705.66 | 0 |
3263404 | 113032 | None | code135 | Supplying 11 kV, Jointing & Cable Termination Kit as
per IS-13573- Heat Shrinkable Type Transition Jointing Kit for
XLPE Cable- 3x95Sqmm | Set | 5931.0 | 5931.0 | 2.0 | False | None | None | False | None | False | 11862.0 | 0 |
3263405 | 113032 | None | code136 | Earth work excavation for cable trench of 0.5 to 0.75 Mtr. Width and Depth
upto 1 Mtr including trial pits, depositing on bank upto a lead of 50 Mtr,
Supplying and Displaying necessary Danger Boards and Lighting, Using sight
Rails and Sign Boards at every 100 Mtr wherever necessary as directed.in hard soil | Cum | 260.0 | 260.0 | 28.0 | False | None | None | False | None | False | 7280.0 | 0 |
3263406 | 113032 | None | code137 | Refilling the cable trenches with selected available earth from trench excavation
including watering, consolidation in layers of 15 cm. Thickness including
depositing of the surplus earth with a all lead | Cum | 58.0 | 58.0 | 30.0 | False | None | None | False | None | False | 1740.0 | 0 |
3263407 | 113032 | None | code138 | Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary. 19/20mm dia 2mm thick | Mtr | 69.3 | 69.3 | 110.0 | False | None | None | False | None | False | 7623.0 | 0 |
3263408 | 113032 | None | code139 | Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary. 25mm dia 2mm thick | Mtr | 81.9 | 81.9 | 30.0 | False | None | None | False | None | False | 2457.0 | 0 |
3263409 | 113032 | None | code140 | Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 19/20mm dia 2mm thick | Mtr | 71.4 | 71.4 | 20.0 | False | None | None | False | None | False | 1428.0 | 0 |
3263410 | 113032 | None | code141 | Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 25mm dia 2mm thick | Mtr | 82.95 | 82.95 | 10.0 | False | None | None | False | None | False | 829.5 | 0 |
3263411 | 113032 | None | code142 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or
sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work-
In all kinds of soils Depth upto 3 m , Ordinary soil | Cum | 107.1 | 107.1 | 10.06 | False | None | None | False | None | False | 1077.426 | 0 |
3263412 | 113032 | None | code143 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work- In all kinds of soils Depth upto | Cum | 381.15 | 381.15 | 10.06 | False | None | None | False | None | False | 3834.369 | 0 |
3263413 | 113032 | None | code144 | Extra for every additional lift of 1.5 m or part thereof in excavation/banking excavated or stacked materials. | Cum | 91.35 | 91.35 | 4.21 | False | None | None | False | None | False | 384.5835 | 0 |
3263414 | 113032 | None | code145 | Filling approved earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | Cum | 454.65 | 454.65 | 0.94 | False | None | None | False | None | False | 427.371 | 0 |
3263415 | 113032 | None | code146 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)-- Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6288.5 | 6288.5 | 0.95 | False | None | None | False | None | False | 5974.075 | 0 |
3263416 | 113032 | None | code147 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished
layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates . | Cum | 6639.15 | 6639.15 | 1.63 | False | None | None | False | None | False | 10821.8145 | 0 |
3263417 | 113032 | None | code148 | Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 7303.06 | 7303.06 | 4.89 | False | None | None | False | None | False | 35711.9634 | 0 |
3263418 | 113032 | None | code149 | Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever requiredsmooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 371.7 | 371.7 | 28.1 | False | None | None | False | None | False | 10444.77 | 0 |
3263419 | 113032 | None | code150 | Providing and laying water proofing treatment to the Water tanks & Liquid Retaining structures with two component acrylic polymer modified cementitious waterproofing membrane with minimum elongation of 50% applied @ 1.5 kg/m2 for internal side waterproofing in two layers with waiting period of 4-6 hrs per layer and food grade epoxy coating in two coats certified by CFTRI Mysuru, including surface preparation completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge | Sqm | 532.35 | 532.35 | 17.78 | False | None | None | False | None | False | 9465.183 | 0 |
3263420 | 113032 | None | code151 | Providing and fixing SFRC frame and cover conforming to IS 12592 (part-I)-1988 and IS 12592 (part-II)- 1991 with latest amendment, including cutting slabs to the required size for the opening and fixing the cover in C.C. 1:2:4 and C.M. 1:3 plastering 20 mm thick to all exposed faces, curing for 10 days with all lead and lift with appurtenances. complete. | No | 2692.2 | 2692.2 | 1.0 | False | None | None | False | None | False | 2692.2 | 0 |