createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1718019438308
version4
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee2940.00
emd200000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose24-06-2024 16:00:00
tenderQueryClose19-06-2024 16:00:00
technicalBidOpen26-06-2024 16:00:00
publishedDate10-06-2024 19:54:44
publishedByPostKHB_EE_CO_BNG
publishedByUserKPE11677 - SHIVASHANKARAPPA K H
bidValidityPeriod180
noOfCalls1
preBidMeetingDate20-06-2024 11:00:00
preBidMeetingYnTrue
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonSHIVASHANKARAPPA K H
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumber08022273511
mobileNumber8022273511
tenderSupplierListNone
tenderSchedule
createdTs1718019438335
version7
createdDateNone
modifiedDateNone
tenderNumberKHB/2024-25/BD/WORK_INDENT238
titleConstruction of Post Metric Girls Hostel 2nd Phase at K R Pet, Mandya District
descriptionConstruction of Post Metric Girls Hostel 2nd Phase at K R Pet, Mandya District
categoryWORKS
categoryTextWorks
ecv11759094.00
deptNameKarnataka Housing Board
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnFalse
location5488
locationNameKHB Central Office Bengaluru
provisionalAmount11759094.0
groupOverheadTotalNone
fileNumber108/2024-25
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17180194380000NoneNoneBuildingsConstruction of Post Metric Medical & Engineering Girls Hostel 2nd Phase at K R Pet, Mandya District11759094.0
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3261391112977Nonecode01Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)--M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 70% ON CONCRETE ITEM)Cum12460.2812460.287.61FalseNoneNoneFalseNoneFalse94822.73080
3261392112977Nonecode02Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)-- Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 70% ON CONCRETE ITEM)Cum12581.212581.23.97FalseNoneNoneFalseNoneFalse49947.3640
3261393112977Nonecode03Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)--M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 60% ON CONCRETE ITEM)Cum11726.1611726.168.47FalseNoneNoneFalseNoneFalse99320.57520
3261394112977Nonecode04Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)--M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 60% ON CONCRETE ITEM) -Terrace FloorCum11841.1311841.130.49FalseNoneNoneFalseNoneFalse5802.15370
3261395112977Nonecode05Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)-- Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates(60% shuttering charge)Cum10653.310653.37.1FalseNoneNoneFalseNoneFalse75638.430
3261396112977Nonecode06Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)-- Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates(60% shuttering charge)Cum10757.8810757.880.24FalseNoneNoneFalseNoneFalse2581.89120
3261397112977Nonecode07Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specificationsSqm1403.151403.15346.66FalseNoneNoneFalseNoneFalse486415.9790
3261398112977Nonecode08Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications-Terrace FloorSqm1417.171417.17104.88FalseNoneNoneFalseNoneFalse148632.78960
3261399112977Nonecode09Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.Sqm1182.51182.514.49FalseNoneNoneFalseNoneFalse17134.4250
3261400112977Nonecode10Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)--M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 50% ON CONCRETE ITEM)Cum10993.2810993.2826.98FalseNoneNoneFalseNoneFalse296598.69440
3261401112977Nonecode11Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)--M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 30% ON CONCRETE ITEM)Cum10626.8410626.840.5FalseNoneNoneFalseNoneFalse5313.420
3261402112977Nonecode12Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately)Kg93.9293.9210563.7926FalseNoneNoneFalseNoneFalse992151.4009920
3261403112977Nonecode13Providing Red Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications.Cum104580.0104580.00.51FalseNoneNoneFalseNoneFalse53335.80
3261404112977Nonecode14providing & fixing of 2.5 track x 2 panel sliding windows made out of multi chambered UPVC(Matching to RAL 9016) sections and with minimum Ti02 (Titanium Dioxide) at 6PHR with TPE( Thermo Plastic Elastomer) and lead free, gaskets grey colour having isolated drainage and reinforced with Galvanized Iron profile through out the window frame. The outer frame having an overall size of 94mm width x 45mm height with reinforcement of 1mm thickness and Sash with overall size of 39mm x 58mm with G reinforcement of 1.5mm and mesh sash of size 25mm x 42mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm 2.5mm. Maximum possible size 1819mm x 1819mm. (The cost is inclusive of all fixtures and separate charges for minor T&Ps shall not be made)Sqm6878.556878.5532.4FalseNoneNoneFalseNoneFalse222865.020
3261405112977Nonecode15Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with G reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)Sqm3488.13488.114.4FalseNoneNoneFalseNoneFalse50228.640
3261406112977Nonecode16Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges.-with both side prelamSqm2534.02534.06.3FalseNoneNoneFalseNoneFalse15964.20
3261407112977Nonecode17Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by weldingKg176.4176.4810.0FalseNoneNoneFalseNoneFalse142884.00
3261408112977Nonecode18Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete.No126.0126.010.0FalseNoneNoneFalseNoneFalse1260.00
3261409112977Nonecode19Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.No1104.61104.610.0FalseNoneNoneFalseNoneFalse11046.00
3261410112977Nonecode20Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. complete.No248.85248.8520.0FalseNoneNoneFalseNoneFalse4977.00
3261411112977Nonecode21Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete.No136.5136.530.0FalseNoneNoneFalseNoneFalse4095.00
3261412112977Nonecode22Providing and fixing ISI marked M.S. pressed butt hinges bright finished with necessary screws etc.-125x65x2.12mm.No57.7557.7540.0FalseNoneNoneFalseNoneFalse2310.00
3261413112977Nonecode23Providing and fixing MS Hold fastsNo52.552.540.0FalseNoneNoneFalseNoneFalse2100.00
3261414112977Nonecode24Providing 12 mm cement plaster with Cement mortar 1:3 (1cement: 3 coarse sand) finished with a floating coat of neat cement to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing completeSqm339.15339.15163.86FalseNoneNoneFalseNoneFalse55573.1190
3261415112977Nonecode25Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm384.3384.3699.81FalseNoneNoneFalseNoneFalse268936.9830
3261416112977Nonecode26Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm309.75309.7560.26FalseNoneNoneFalseNoneFalse18665.5350
3261417112977Nonecode27Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm412.34412.34355.79FalseNoneNoneFalseNoneFalse146706.44860
3261418112977Nonecode28Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)-- Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregatesCum6527.856527.8516.39FalseNoneNoneFalseNoneFalse106991.46150
3261419112977Nonecode29Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)--M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Basic rate: 6492.00Cum7328.857328.85163.86FalseNoneNoneFalseNoneFalse1200905.3610
3261420112977Nonecode30Providing 12 mm cement plaster with Cement mortar 1:3 (1cement: 3 coarse sand) finished with a floating coat of neat cement to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing completeSqm345.93345.93163.86FalseNoneNoneFalseNoneFalse56684.08980
3261421112977Nonecode31Providing and laying cinder concrete in cement 1:15 (1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications.Cum2160.212160.210.52FalseNoneNoneFalseNoneFalse1123.30920
3261422112977Nonecode32Providing and laying flamed finised Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent.Sqm2641.092641.0945.2FalseNoneNoneFalseNoneFalse119377.2680
3261423112977Nonecode33Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.-- Size of Tile (600X600) mmSqm1226.31226.3147.96FalseNoneNoneFalseNoneFalse181443.3480
3261424112977Nonecode34Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., completeSqm952.12952.1210.1FalseNoneNoneFalseNoneFalse9616.4120
3261425112977Nonecode35Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per m2, including pointing in white cement mixed with pigment of matching shade complete.Sqm1184.531184.5383.37FalseNoneNoneFalseNoneFalse98754.26610
3261426112977Nonecode36Providing and laying flooring and steps machine cut granite slabs 40 mm thick on cement mortar bed 1:6, 25 mm thick, and pointed with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar labour, curing complete as per specifications.Sqm4582.814582.814.68FalseNoneNoneFalseNoneFalse21447.55080
3261427112977Nonecode37Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.Sqm107.1107.1615.29FalseNoneNoneFalseNoneFalse65897.5590
3261428112977Nonecode38Finishing with Deluxe Multi surface paint system for interiors andexteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Specialprimer applied @ 0.75 ltr /10 m² with paint of approved quality to givean even shade, after thoroughly brooming the surface to remove all dirt,dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm169.22169.221664.33FalseNoneNoneFalseNoneFalse281637.92260
3261429112977Nonecode39Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm186.35186.35273.86FalseNoneNoneFalseNoneFalse51033.8110
3261430112977Nonecode40Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm306.31306.3141.08FalseNoneNoneFalseNoneFalse12583.21480
3261431112977Nonecode41Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/ litre as per specifications and as per directions of Engineer in charge.Sqm59.9859.9837.44FalseNoneNoneFalseNoneFalse2245.65120
3261432112977Nonecode42Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/ litre as per specifications and as per directions of Engineer in charge.Sqm60.5660.563.74FalseNoneNoneFalseNoneFalse226.49440
3261433112977Nonecode43Polishing on wood work with ready mixed wax polish of approved brand and manufacture : New work to give an even surface including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm144.59144.5937.44FalseNoneNoneFalseNoneFalse5413.44960
3261434112977Nonecode44Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for:-PVC pipes 110mm dia., 6 kg/sqcm & class 3Mtr440.18440.1844.0FalseNoneNoneFalseNoneFalse19367.920
3261435112977Nonecode45Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge.Sqm875.01875.01163.86FalseNoneNoneFalseNoneFalse143379.13860
3261436112977Nonecode46KSRB 15.8.3 Providing and fixing plaster mesh 100mm wide manufactured out of hot dipped galvanized iron of nominal thickness 0.35mm with a zinc coating of 120gms per Sqm width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. (length of mesh only be measured for payment)Mtr47.1247.12208.38FalseNoneNoneFalseNoneFalse9818.86560
3261437112977Nonecode47Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required-White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot restsNo5230.765230.761.0FalseNoneNoneFalseNoneFalse5230.760
3261438112977Nonecode48Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lidNo6401.376401.371.0FalseNoneNoneFalseNoneFalse6401.370
3261439112977Nonecode49Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required: using White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixerNo3069.493069.492.0FalseNoneNoneFalseNoneFalse6138.980
3261440112977Nonecode50Providing and fixing 100 mm sand cast Iron grating for gully trap.No50.3450.344.0FalseNoneNoneFalseNoneFalse201.360
3261441112977Nonecode51Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931.No776.46776.464.0FalseNoneNoneFalseNoneFalse3105.840
3261442112977Nonecode52Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 g.No906.07906.074.0FalseNoneNoneFalseNoneFalse3624.280
3261443112977Nonecode53Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end)-25mm nominal boreNo587.08587.081.0FalseNoneNoneFalseNoneFalse587.080
3261444112977Nonecode54Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end)-32mm nominal boreNo640.46640.461.0FalseNoneNoneFalseNoneFalse640.460
3261445112977Nonecode55Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.No1306.621306.622.0FalseNoneNoneFalseNoneFalse2613.240
3261446112977Nonecode56Towel rail-600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g.No531.22531.224.0FalseNoneNoneFalseNoneFalse2124.880
3261447112977Nonecode57Providing and fixing Chorinated Poly Venly Cloride (CPVC) pipes conforming to IS15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr. spacing. This includes jointing of pipes and fitting with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete. (concealed work including cutting chases and good the walls etc), For 50 mm diaMtr836.45836.4510.0FalseNoneNoneFalseNoneFalse8364.50
3261448112977Nonecode58Providing and fixing Chorinated Poly Venly Cloride (CPVC) pipes conforming to IS15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr. spacing. This includes jointing of pipes and fitting with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete. (concealed work including cutting chases and good the walls etc), For 32 mm diaMtr428.4428.410.0FalseNoneNoneFalseNoneFalse4284.00
3261449112977Nonecode59Providing and fixing Chorinated Poly Venly Cloride (CPVC) pipes conforming to IS15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr. spacing. This includes jointing of pipes and fitting with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete. (concealed work including cutting chases and good the walls etc), For 25 mm diaMtr340.58340.5810.0FalseNoneNoneFalseNoneFalse3405.80
3261450112977Nonecode60Providing and fixing Chorinated Poly Venly Cloride (CPVC) pipes conforming to IS15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr. spacing. This includes jointing of pipes and fitting with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete. (concealed work including cutting chases and good the walls etc), For 20 mm diaMtr259.18259.1810.0FalseNoneNoneFalseNoneFalse2591.80
3261451112977Nonecode61Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tankLtr4.284.285000.0FalseNoneNoneFalseNoneFalse21400.00
3261452112977Nonecode62Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work- In all kinds of soils Depth upto 3 m-All soilsCum107.1107.180.92FalseNoneNoneFalseNoneFalse8666.5320
3261453112977Nonecode63Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work- In all kinds of soils Depth upto 3 m-Hard SoilCum381.15381.1517.21FalseNoneNoneFalseNoneFalse6559.59150
3261454112977Nonecode64Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fineaggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)-Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregatesCum5947.25947.27.31FalseNoneNoneFalseNoneFalse43474.0320
3261455112977Nonecode65Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately)-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 8% ON CONCRETE ITEM)Cum7129.467129.465.74FalseNoneNoneFalseNoneFalse40923.10040
3261456112977Nonecode66Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other---- M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 50% ON CONCRETE ITEM)Cum9979.29979.210.4FalseNoneNoneFalseNoneFalse103783.680
3261457112977Nonecode67Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work.Cum497.7497.716.29FalseNoneNoneFalseNoneFalse8107.5330
3261458112977Nonecode68Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)-- M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 70% ON CONCRETE ITEM)Cum12214.7612214.767.04FalseNoneNoneFalseNoneFalse85991.91040
3261459112977Nonecode69Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately)-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 8% ON CONCRETE ITEM)Cum7129.467129.465.74FalseNoneNoneFalseNoneFalse40923.10040
3261460112977Nonecode70Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other---- M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 50% ON CONCRETE ITEM)Cum9979.29979.210.4FalseNoneNoneFalseNoneFalse103783.680
3261461112977Nonecode71Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work.Cum497.7497.716.29FalseNoneNoneFalseNoneFalse8107.5330
3261462112977Nonecode72Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.Sqm1292.551292.55145.8FalseNoneNoneFalseNoneFalse188453.790
3261463112977Nonecode73Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)-- Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 60% ON CONCRETE ITEM)Cum9465.389465.381.37FalseNoneNoneFalseNoneFalse12967.57060
3261464112977Nonecode74Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work.Cum9979.29979.210.4FalseNoneNoneFalseNoneFalse103783.680
3261465112977Nonecode75Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-incharge.Sqm471.45471.45328.32FalseNoneNoneFalseNoneFalse154786.4640
3261466112977Nonecode76Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in charge.Sqm182.7182.7328.32FalseNoneNoneFalseNoneFalse59984.0640
3261467112977Nonecode77Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : vol- 2 Cement mortar 1:6 (1 cement : 6 coarse sand)Cum5891.555891.5525.02FalseNoneNoneFalseNoneFalse147406.5810
3261468112977Nonecode78Providing and fixing concertina coil fencing with punched tape concertina coil 600 mm dia 10 metre openable length ( total length 90 m), having 50 nos rounds per 6 metre length, upto 3 m height of wall with existing angle iron 'Y' shaped placed 2.4m or 3.00 m apart and with 9 horizontal R.B.T. reinforced barbed wire, stud tied with G.I. staples and G.I. clips to retain horizontal, including necessary bolts or G.I. barbed wire tied to angle iron, all complete as per direction of Engineer-in-charge, with reinforced barbed tape(R.B.T.) / Spring core (2.5mm thick) wire of high tensile strength of 165 kg/mm2 with tape (0.52 mm thick) and weight 43.478 g/m (cost of M.S. angle, C.C. blocks shall be paid separately)Mtr331.8331.891.2FalseNoneNoneFalseNoneFalse30260.160
3261469112977Nonecode79Supplying & Fixing at site Angle iron post & strut of required size including bottom to be split and bent at right angle in opposite direction for 10 cm length and drilling holes upto 10 mm dia. etc. complete.-Y-ISA Angle-50mmx50mmx3mmKg118.65118.6527.0FalseNoneNoneFalseNoneFalse3203.550
3261470112977Nonecode80Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding issue rate 143Kg176.4176.4455.0FalseNoneNoneFalseNoneFalse80262.00
3261471112977Nonecode81Supplying at site Angle iron post & strut of required size including bottom to be split and bent at right angle in opposite direction for 10 cm length and drilling holes upto 10 mm dia. etc. complete.Kg122.21122.2110250.2FalseNoneNoneFalseNoneFalse1252676.9420
3261472112977Nonecode82Supplying, installing, testing and commissioning of Diesel Generator set with following specifications. Power rating as per standard reference condition as per-BS 5514 / ISO 3046 / ISO 8528 & IS 1002 / ISO 3046 Generator set specifications-Upto 62.50KVAEach754780.95754780.951.0FalseNoneNoneFalseNoneFalse754780.950
3261473112977Nonecode83Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.-short point upto 3 mtr from tapping point to outlet via switch.Point282.45282.4513.0FalseNoneNoneFalseNoneFalse3671.850
3261474112977Nonecode84Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Medium point above 3Mtr up to 6Mtr from tapping point to out let via switchPoint397.95397.9525.0FalseNoneNoneFalseNoneFalse9948.750
3261475112977Nonecode85Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Long point above 6Mtr up to 10Mtr from tapping point to out let via switchPoint582.75582.75100.0FalseNoneNoneFalseNoneFalse58275.00
3261476112977Nonecode86Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Two outlet in a row, above 3Mtr up to 6Mtr from tapping point to out let via switchesPoint710.85710.8520.0FalseNoneNoneFalseNoneFalse14217.00
3261477112977Nonecode87Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Three outlet in a row, above 6Mtr up to 10Mtr from tapping point to out let via switchesPoint1038.451038.456.0FalseNoneNoneFalseNoneFalse6230.70
3261478112977Nonecode88Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 3WayEach166.95166.95183.0FalseNoneNoneFalseNoneFalse30551.850
3261479112977Nonecode89Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 6WayEach231.0231.050.0FalseNoneNoneFalseNoneFalse11550.00
3261480112977Nonecode90Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 10-12WayEach334.95334.9530.0FalseNoneNoneFalseNoneFalse10048.50
3261481112977Nonecode91Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 3 ModuleEach169.05169.05183.0FalseNoneNoneFalseNoneFalse30936.150
3261482112977Nonecode92Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 6 ModuleEach245.7245.750.0FalseNoneNoneFalseNoneFalse12285.00
3261483112977Nonecode93Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 10 to 12 ModuleEach274.05274.0530.0FalseNoneNoneFalseNoneFalse8221.50
3261484112977Nonecode94Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps one way SwitchEach107.1107.1400.0FalseNoneNoneFalseNoneFalse42840.00
3261485112977Nonecode95Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps Two way SwitchEach174.3174.310.0FalseNoneNoneFalseNoneFalse1743.00
3261486112977Nonecode96Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps 3way socketEach179.55179.55200.0FalseNoneNoneFalseNoneFalse35910.00
3261487112977Nonecode97Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Stepped Fan Regulator.Each374.85374.8545.0FalseNoneNoneFalseNoneFalse16868.250
3261488112977Nonecode98Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 16Amps one way switchEach189.0189.020.0FalseNoneNoneFalseNoneFalse3780.00
3261489112977Nonecode99Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 32Amps DP switchEach393.75393.755.0FalseNoneNoneFalseNoneFalse1968.750
3261490112977Nonecode100Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6/16Amps universal socketEach247.8247.850.0FalseNoneNoneFalseNoneFalse12390.00
3261491112977Nonecode101Supplying and fixing of Metal Socket set of 2pole and earth plugs and socket for incorporating SP and TP MCB (Without MCB).The entire plug and socket shall be mounted in a thermoplastic I powder coated metal box & wired Completely. 20 AEach916.65916.652.0FalseNoneNoneFalseNoneFalse1833.30
3261492112977Nonecode102Supplying and fixing of MODULAR MCB Devices(Tripper) With Breaking capacity of 6KA. 16 - 32 A SPEach199.5199.52.0FalseNoneNoneFalseNoneFalse399.00
3261493112977Nonecode103Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 19/20mm dia 2mm thickMtr69.369.33500.0FalseNoneNoneFalseNoneFalse242550.00
3261494112977Nonecode104Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 25mm dia 2mm thickMtr81.981.9150.0FalseNoneNoneFalseNoneFalse12285.00
3261495112977Nonecode105Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 32mm dia 2.5mm thickMtr108.15108.1550.0FalseNoneNoneFalseNoneFalse5407.50
3261496112977Nonecode106Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 19/20mm dia 2mm thickMtr71.471.41000.0FalseNoneNoneFalseNoneFalse71400.00
3261497112977Nonecode107Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 25mm dia 2mm thickMtr82.9582.95500.0FalseNoneNoneFalseNoneFalse41475.00
3261498112977Nonecode108Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 32mm dia 2.5mm thickMtr103.95103.9525.0FalseNoneNoneFalseNoneFalse2598.750
3261499112977Nonecode109Supplying and fixing PVC/metal conduit Deep junction box 25mm deep junction boxNo58.858.8130.0FalseNoneNoneFalseNoneFalse7644.00
3261500112977Nonecode110Supplying and fixing PVC/metal conduit Deep junction box 32 mm deep junction boxNo64.0564.0540.0FalseNoneNoneFalseNoneFalse2562.00
3261501112977Nonecode111Supplying And Fixing Metal Fan Box with Round Hook.No122.85122.85100.0FalseNoneNoneFalseNoneFalse12285.00
3261502112977Nonecode112Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5 sqmmMtr27.327.32200.0FalseNoneNoneFalseNoneFalse60060.00
3261503112977Nonecode113Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.5 sqmmMtr44.144.12500.0FalseNoneNoneFalseNoneFalse110250.00
3261504112977Nonecode114Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 4 sqmmMtr66.1566.15500.0FalseNoneNoneFalseNoneFalse33075.00
3261505112977Nonecode115Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 6 sqmmMtr96.696.6900.0FalseNoneNoneFalseNoneFalse86940.00
3261506112977Nonecode116Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure-8waySPNEach1946.71946.72.0FalseNoneNoneFalseNoneFalse3893.40
3261507112977Nonecode117Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32Amps SPEach435.75435.7522.0FalseNoneNoneFalseNoneFalse9586.50
3261508112977Nonecode118Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32Amps DPEach775.95775.952.0FalseNoneNoneFalseNoneFalse1551.90
3261509112977Nonecode119Supplying, fixing and wiring Residential Circuit Breaker [RCCB] 240/450V up to 300mA sensitivity on existing wood/panel board-16A-25A 2 PoleEach4490.854490.852.0FalseNoneNoneFalseNoneFalse8981.70
3261510112977Nonecode120Supplying of ......feet - PVC Batten with integrated LED tube .....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.-LED light fighting 1x4'-20/22wEach724.5724.565.0FalseNoneNoneFalseNoneFalse47092.50
3261511112977Nonecode121Supplying & fixing of retrofit type - LED bulb.......W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70%. efficacy 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.-12 W6500kEach282.45282.452.0FalseNoneNoneFalseNoneFalse564.90
3261512112977Nonecode122Supplying exhaust fan of 1440 RPM of 300mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply.Each1566.61566.68.0FalseNoneNoneFalseNoneFalse12532.80
3261513112977Nonecode123Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system.48"sweep(1200mm) Regular modelEach3133.23133.247.0FalseNoneNoneFalseNoneFalse147260.40
3261514112977Nonecode124Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S'' hook with fan regulator to the existing board together with supplying and fixing 5 A. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring.Each179.55179.5545.0FalseNoneNoneFalseNoneFalse8079.750
3261515112977Nonecode125Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps.-on wall/ceiling/rafter/girdersEach128.1128.162.0FalseNoneNoneFalseNoneFalse7942.20
3261516112977Nonecode126Supplying & laying of of 11 kV, 3 Core, XPLE HTUG Cable with pressure extruded inner sheeth, ROUND WIRE ARMOURED as per IS-7098 (Part-2)Armouring wires dia and Resistivity as per IS-3975-95 sqmm, ( 54 GI Wires-2.5mm dia)Km1160899.01160899.00.7FalseNoneNoneFalseNoneFalse812629.30
3261517112977Nonecode127Supplying 11 kV, Jointing & Cable Termination Kit as per IS-13573- Heat Shrinkable Type Transition Jointing Kit for XLPE Cable- 3x95SqmmSet5931.05931.02.0FalseNoneNoneFalseNoneFalse11862.00
3261518112977Nonecode128Earth work excavation for cable trench of 0.5 to 0.75 Mtr. Width and Depth upto 1 Mtr including trial pits, depositing on bank upto a lead of 50 Mtr, Supplying and Displaying necessary Danger Boards and Lighting, Using sight Rails and Sign Boards at every 100 Mtr wherever necessary as directed.in hard soilCum260.0260.028.0FalseNoneNoneFalseNoneFalse7280.00
3261519112977Nonecode129Refilling the cable trenches with selected available earth from trench excavation including watering, consolidation in layers of 15 cm. Thickness including depositing of the surplus earth with a all leadCum58.058.030.0FalseNoneNoneFalseNoneFalse1740.00
3261520112977Nonecode130Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary. 19/20mm dia 2mm thickMtr69.369.3125.0FalseNoneNoneFalseNoneFalse8662.50
3261521112977Nonecode131Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary. 25mm dia 2mm thickMtr81.981.930.0FalseNoneNoneFalseNoneFalse2457.00
3261522112977Nonecode132Supply of DP Structure using RCC Pole - 9 Mtr Long, 145 Kg WL (Including Cost of Poles)Set21974.421974.42.0FalseNoneNoneFalseNoneFalse43948.80
3261523112977Nonecode133Erection DP Structure using RCC Pole - 9 Mtr Long, 145 Kg WLSet5640.65640.62.0FalseNoneNoneFalseNoneFalse11281.20
3261524112977Nonecode134Supply& erection of 11 kV, 45 KN Polymeric InsulatorNo195.3195.312.0FalseNoneNoneFalseNoneFalse2343.60
3261525112977Nonecode135Supply of Guy Set Complete with No. 15 Strain InsulatorSet1228.51228.53.0FalseNoneNoneFalseNoneFalse3685.50
3261526112977Nonecode136Erection of Guy Set Complete with No. 15 Strain InsulatorSet622.65622.653.0FalseNoneNoneFalseNoneFalse1867.950
3261527112977Nonecode137Supply of Spiral Earth ElectrodeNo250.95250.953.0FalseNoneNoneFalseNoneFalse752.850
3261528112977Nonecode138Erection of Spiral Earth ElectrodeNo97.6597.653.0FalseNoneNoneFalseNoneFalse292.950
3261529112977Nonecode139Supply& fixing of Guy concreting with Boulders, Mud and SandNo262.5262.53.0FalseNoneNoneFalseNoneFalse787.50
3261530112977Nonecode140Supply of Caution/Danger BoardNo157.5157.52.0FalseNoneNoneFalseNoneFalse315.00
3261531112977Nonecode141Fixing of Caution/Danger BoardNo84.084.02.0FalseNoneNoneFalseNoneFalse168.00
3261532112977Nonecode142Supply of Anti Climbing Device (12 Mtr GI Barbed WireEach93.4593.453.0FalseNoneNoneFalseNoneFalse280.350
3261533112977Nonecode143Erection of Anti Climbing Device (12 Mtr GI Barbed WireEach44.144.13.0FalseNoneNoneFalseNoneFalse132.30
3261534112977Nonecode144Supply and fixing of 11 kV, 400 Amps Double Break GOSSet21974.421974.43.0FalseNoneNoneFalseNoneFalse65923.20
3261535112977Nonecode145Fixing of 11 kV, 400 Amps Double Break GOSSet1274.71274.73.0FalseNoneNoneFalseNoneFalse3824.10
3261536112977Nonecode146Supply of H-Frame for mounting GOSNo4348.64348.62.0FalseNoneNoneFalseNoneFalse8697.20
3261537112977Nonecode147fixing of H-Frame for mounting GOSNo339.15339.152.0FalseNoneNoneFalseNoneFalse678.30
3261538112977Nonecode148Supply of DOLO Cut Out -Set/3 NosSet6165.66165.61.0FalseNoneNoneFalseNoneFalse6165.60
3261539112977Nonecode149Erection of DOLO Cut Out -Set/3 NosSet248.85248.851.0FalseNoneNoneFalseNoneFalse248.850
3261540112977Nonecode150Supply RCC Pole - 9 Mtr Long, 145 Kg WL as per IS- 785Set7429.87429.81.0FalseNoneNoneFalseNoneFalse7429.80
3261541112977Nonecode151Erection of RCC Pole - 9 Mtr Long, 145 Kg WL as per IS- 785Set1829.11829.12.0FalseNoneNoneFalseNoneFalse3658.20
3261542112977Nonecode152Supply of 11 kV, Horizontal Cross Arm with clamps, HTST supports, bolts, nuts and washers for RCC Pole - 9 Mtr Long, 145 Kg WLSet678.3678.32.0FalseNoneNoneFalseNoneFalse1356.60
3261543112977Nonecode153Erection of 11 kV, Horizontal Cross Arm with clamps, HTST supports, bolts, nuts and washers for RCC Pole - 9 Mtr Long, 145 Kg WLSet285.6285.62.0FalseNoneNoneFalseNoneFalse571.20
3261544112977Nonecode154Supply and fixing of 11 kV, 5 KN Polymeric Pin Insulator (24 mm Dia FRP Rod)No215.25215.256.0FalseNoneNoneFalseNoneFalse1291.50
3261545112977Nonecode155Supply and fixing of 11 kV, 45 KN Polymeric InsulatorNo195.3195.36.0FalseNoneNoneFalseNoneFalse1171.80
3261546112977Nonecode156Supply of Guy Set Complete with No. 15 Strain InsulatorSet1228.51228.52.0FalseNoneNoneFalseNoneFalse2457.00
3261547112977Nonecode157Erection of Guy Set Complete with No. 15 Strain InsulatorSet622.65622.652.0FalseNoneNoneFalseNoneFalse1245.30
3261548112977Nonecode158Supply of Rabbit ACSR ConductorKm48545.748545.70.25FalseNoneNoneFalseNoneFalse12136.4250
3261549112977Nonecode159Erection of Rabbit ACSR ConductorKm4579.054579.050.25FalseNoneNoneFalseNoneFalse1144.76250
3261550112977Nonecode160Supply and fixing of PG Clamps for Rabbit ConductorNo107.1107.115.0FalseNoneNoneFalseNoneFalse1606.50
3261551112977Nonecode161Supply of Spiral Earth ElectrodeNo250.95250.952.0FalseNoneNoneFalseNoneFalse501.90
3261552112977Nonecode162Erection of Spiral Earth ElectrodeNo97.6597.652.0FalseNoneNoneFalseNoneFalse195.30
3261553112977Nonecode163Supply of EG Stirrups with GI wire lacing - set/2 Nos.Set289.8289.82.0FalseNoneNoneFalseNoneFalse579.60
3261554112977Nonecode164Erection of EG Stirrups with GI wire lacing-set/2 Nos.Set168.0168.02.0FalseNoneNoneFalseNoneFalse336.00
3261555112977Nonecode165Guy concreting with Boulders, Mud and SandNo262.5262.52.0FalseNoneNoneFalseNoneFalse525.00
3261556112977Nonecode166Supply of Caution/Danger BoardNo157.5157.53.0FalseNoneNoneFalseNoneFalse472.50
3261557112977Nonecode167Erection of Caution/Danger BoardNo84.084.03.0FalseNoneNoneFalseNoneFalse252.00
3261558112977Nonecode168Supply of Anti Climbing Device (12 Mtr GI Barbed WireEach93.4593.452.0FalseNoneNoneFalseNoneFalse186.90
3261559112977Nonecode169Erection of Anti Climbing Device (12 Mtr GI Barbed WireEach44.144.12.0FalseNoneNoneFalseNoneFalse88.20
3261560112977Nonecode170supplying of DP Transformer Structure using PSCC Pole - 9 Mtr Long, 300 Kg WL (Including Cost of Poles)No29051.429051.45.0FalseNoneNoneFalseNoneFalse145257.00
3261561112977Nonecode171supplying & fixing of 11 kV, 5 KN Polymeric Pin Insulator (24 mm Dia FRP Rod)Set215.25215.254.0FalseNoneNoneFalseNoneFalse861.00
3261562112977Nonecode172supplying & fixing of 11 kV, 45 KN Polymeric InsulatorSet195.3195.34.0FalseNoneNoneFalseNoneFalse781.20
3261563112977Nonecode173Supplying of Guy Set Complete with No. 15 Strain InsulatorNo1228.51228.54.0FalseNoneNoneFalseNoneFalse4914.00
3261564112977Nonecode174Supplying of 11 kV/433V, 63 kVA, 3 Phase, 50 Cys Distribution Transformer BEE - 5 Star Rated with OilNo91672.2591672.253.0FalseNoneNoneFalseNoneFalse275016.750
3261565112977Nonecode175Supplying of Earthing materials pipe type for grounding (Single Electrode with accessories)Set1815.451815.453.0FalseNoneNoneFalseNoneFalse5446.350
3261566112977Nonecode176Supplying of Caution/Danger BoardNo157.5157.51.0FalseNoneNoneFalseNoneFalse157.50
3261567112977Nonecode177supplying of Anti Climbing Device (12 Mtr GI Barbed Wire)Each93.4593.452.0FalseNoneNoneFalseNoneFalse186.90
3261568112977Nonecode178Supplying & fixing of GI Wire 8 SWGKg78.7978.795.0FalseNoneNoneFalseNoneFalse393.950
3261569112977Nonecode179Supplying & fixing of Guy wire 7/10 SWGKg81.0981.0918.0FalseNoneNoneFalseNoneFalse1459.620
3261570112977Nonecode180Supplying & fixing of 11 kV Lightning Arrester, Metal Oxide 10 kV, 5 kA, Polymeric type with ground disconnector-set/3NosSet4989.64989.63.0FalseNoneNoneFalseNoneFalse14968.80
3261571112977Nonecode181a) Supplying of LT Protection Kit for 63 kVANo2124.152124.153.0FalseNoneNoneFalseNoneFalse6372.450
3261572112977Nonecode182b) LT Wiring (From DTC to LT Line Through Metering Box & LT Protection Kit) SINGLE CIRCUIT-Al lead wire-95 sqmmMtr116.85116.8533.0FalseNoneNoneFalseNoneFalse3856.050
3261573112977Nonecode183ii) Heavy Duty Long Barrel Copper Lug - 95 SqmmNo135.45135.454.0FalseNoneNoneFalseNoneFalse541.80
3261574112977Nonecode184iii) PG Clamp - Rabbit to 95 SqmmNo147.0147.04.0FalseNoneNoneFalseNoneFalse588.00
3261575112977Nonecode185iv) Spacer for DTC WiringNo44.144.18.0FalseNoneNoneFalseNoneFalse352.80
3261576112977Nonecode186v) Fish Plate with necessary Clamps, bolts & nuts etc complete (Galvanised)No277.2277.22.0FalseNoneNoneFalseNoneFalse554.40
3261577112977Nonecode187c) LT Metering box with CTs and necessary wiring for housing ETV Meter (Please see CDS -39)No5905.25905.21.0FalseNoneNoneFalseNoneFalse5905.20
3261578112977Nonecode188d) LT Electronic Tri-Vector Meter 5 Amps, - 0.5/1.0 Accuracy ClassNo3565.83565.81.0FalseNoneNoneFalseNoneFalse3565.80
3261579112977Nonecode189Supplying of 11 kV, Solid Core Type HG Fuse Unit-Set (3 Nos)Set1122.451122.451.0FalseNoneNoneFalseNoneFalse1122.450
3261580112977Nonecode190suppying of 11 kV, 200 Amps, Single Break GOSSet9922.59922.51.0FalseNoneNoneFalseNoneFalse9922.50
3261581112977Nonecode191Fixing of DP Transformer Structure using PSCC Pole - 9 Mtr Long, 300 Kg WL (Including Cost of Poles)No7332.157332.151.0FalseNoneNoneFalseNoneFalse7332.150
3261582112977Nonecode192Fixing of Guy Set Complete with No. 15 Strain InsulatorNo622.65622.656.0FalseNoneNoneFalseNoneFalse3735.90
3261583112977Nonecode193Fixing of 11 kV/433V, 63 kVA, 3 Phase, 50 Cys Distribution Transformer BEE - 5 Star Rated with OilNo1252.651252.651.0FalseNoneNoneFalseNoneFalse1252.650
3261584112977Nonecode194Fixing of Earthing materials pipe type for grounding (Single Electrode with accessories)Set996.45996.453.0FalseNoneNoneFalseNoneFalse2989.350
3261585112977Nonecode195Fixing of Caution/Danger BoardNo84.084.01.0FalseNoneNoneFalseNoneFalse84.00
3261586112977Nonecode196Fixing Anti Climbing Device (12 Mtr GI Barbed Wire)Each44.144.12.0FalseNoneNoneFalseNoneFalse88.20
3261587112977Nonecode197Fixing of Guy concreting with Boulders, Mud and SandNo262.5262.54.0FalseNoneNoneFalseNoneFalse1050.00
3261588112977Nonecode198a) Fixing of LT Protection Kit for 63 kVANo373.8373.82.0FalseNoneNoneFalseNoneFalse747.60
3261589112977Nonecode199b) LT Wiring (From DTC to LT Line Through Metering Box & LT Protection Kit) SINGLE CIRCUITSet996.45996.451.0FalseNoneNoneFalseNoneFalse996.450
3261590112977Nonecode200c) fixing of LT Metering box with CTs and necessary wiring for housing ETV Meter (Please see CDS -39)No908.25908.251.0FalseNoneNoneFalseNoneFalse908.250
3261591112977Nonecode201d) fixing of LT Electronic Tri-Vector Meter 5 Amps, - 0.5/1.0 Accuracy ClassNo504.0504.01.0FalseNoneNoneFalseNoneFalse504.00
3261592112977Nonecode202fixing of 11 kV, Solid Core Type HG Fuse Unit-Set (3 Nos)Set248.85248.851.0FalseNoneNoneFalseNoneFalse248.850
3261593112977Nonecode203Fixing of 11 kV, 200 Amps, Single Break GOSSet1159.21159.21.0FalseNoneNoneFalseNoneFalse1159.20
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17180194390000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17180194390000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17180194390000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17180194390000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17180194390000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
17180194450000NoneNoneELIGIBILITYThe tender document is part and parcel of the agreement.None
17180194500000NoneNoneELIGIBILITYThe contractor shall obtain insurance coverage for all the workers deployed for this work.None
17180194540000NoneNoneELIGIBILITYFurther details of the work or any clarifications can be obtained from the office of the Executive Engineer (Central office), KHB, Cauvery Bhavan, K.G. Road, Bangalore Ph: 080-22273511 ext-317,None
17180194580000NoneNoneELIGIBILITYThe intending bidders are requested to note that they should abide by the detailed instructions and conditions contained in the Tender documents and further modifications done if any.None
17180194620000NoneNoneELIGIBILITYCorrigendum/modification/corrections, if any, will be published in the e procurement Web sites only.None
17180194650000NoneNoneELIGIBILITYKHB reserves the right to withdraw or cancel this invitation to BID/Tender without assigning any reason whatsoeverNone
17180194680000NoneNoneELIGIBILITYThe bidder shall study the Tender document Carefully and quote the ratesNone
17180194720000NoneNoneELIGIBILITYAll scanned documents to be uploaded shall be in original and are to be produced to the Executive Engineer to verify the documents within 3 days from the day of opening of Technical bid for verification, if required.None
17180194760000NoneNoneELIGIBILITYDrawings uploaded are only for Tender Purpose only.None
17180194800000NoneNoneELIGIBILITYGST shall be added separately in the estimate.None
17180194830000NoneNoneELIGIBILITYGST shall be paid to the tendered amount separately.None
17180194870000NoneNoneELIGIBILITYThe bidder should maintain register of laborers deployed and wages paid for the workers and shall produce the documents whenever called for by the competent authority. Remittance towards PF shall be commensurate with the labour component of the work involved.None
17180194900000NoneNoneELIGIBILITYThe bidder shall give an undertaking that they would abide by the provisions of employees provident fund and shall remit PF of labourers to the respective PF offices or else KHB have the right to deduct the PF amount from the work bills and remit the same to respective PF offices.None
17180194950000NoneNoneELIGIBILITYThe contractor shall quote his rates inclusive of PF as per the applicable rate as issued by the PF department from time to timeNone
17180194990000NoneNoneELIGIBILITYThe successful bidder shall give an under taking that they would abide by the provisions of the Employees Provident Fund Act.None
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneMinimum financial turnover (civil engineering construction works) not less than two times the annual payments from this contract (Rs. xxxxx Lakhs)NoneNone
NoneNoneNoneNoneSatisfactoriy completed (atleast 90%) as prime contractor at-least one such similar work of value not less than Rs. xxxxxxx (80% of estimated cost of tender)NoneNone
NoneNoneNoneNoneExecuted in any one year the following minimum quantities of work (Cement Concrete - xxxx cum, Earthwork - xxxx cum, etc) (80% of peak rate of construction)NoneNone
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid Electrical License for executing building electrificatio works and should have executed similar electrical works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid license for executing water supply / sanitary engineering works and should have executed similar works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneOwning the following key and critical equipment for this work (xxxx, xxxx, xxxx)NoneNone
NoneNoneNoneNoneLiquid assets and /or availability of credit facilities of no less than Rs. xxxxxx Lakhs (estimated cash flow for 3 months of peak construction period)NoneNone
NoneNoneNoneNoneTotal value of civl engineering works executed and payments received in the last five years (year-wise)NoneNone
NoneNoneNoneNoneList of existing commitments and ongoing worksNoneNone
NoneNoneNoneNoneList of works for which tenders already submittedNoneNone
NoneNoneNoneNoneBanker Details for referenceNoneNone
NoneNoneNoneNoneConstruction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneReports on the financial standing of the tenderer, such as profit and loss statements and auditor’s reports for the last five yearsNoneNone
NoneNoneNoneNoneQualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneList of Financial Resources with CertificatesNoneNone
NoneNoneNoneNoneTo qualify for award of this contract , each tenderer in its name should have in the last five years achieved in at least two financial years a minimum financial turnover (In all classes of civil engineering construction works only)Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNoneScanned Copy of documentary proof for having executed similar nature of work not less than 50% of tender amount as defined in Government order No.FD 480 EXP-12/2014,Bangalore dated:19.07.2014Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneScanned copy of latest GST clearance certificate.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Scanned copy of latest GST clearance certificate.
NoneNoneNoneNoneScanned copy of Pre-qualification letter issued by Karnataka Housing Board.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Scanned copy of Pre-qualification letter issued by Karnataka Housing Board.
NoneNoneNoneNoneAs per Tender Documents KW-4 clause 3.3 key & critical equipments available.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- As per Tender Documents KW-4 clause 3.3 key & critical equipments available.
NoneNoneNoneNoneExecuted in any one Financial year, the minimum quantities of work as mentioned in tender documentCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Executed in any one Financial year, the minimum quantities of work as mentioned in tender document
NoneNoneNoneNoneRequired valid electrical license for executing similar nature of work as per tender documentCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Required valid electrical license for executing similar nature of work as per tender document
NoneNoneNoneNoneThe Tenderer should have executed similar water supply/sanitary engineering works as per tender documentCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- The Tenderer should have executed similar water supply/sanitary engineering works as per tender document
NoneNoneNoneNoneIncome Tax returns & PANFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneITR Filed Copy (Mentioning PAN)
NoneNoneNoneNoneGST Registration CertificateFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneGST Registration
NoneNoneNoneNoneScanned copy of Credit lines/ letter of credit /Bankers certificate for at least 20% of amount put to tender in the current financial year on the name of work put to tender.Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneLine of Credit
NoneNoneNoneNoneAssessed Available Bid Capacity as per tender documentFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Assessed Available Bid Capacity as per tender document
NoneNoneNoneNoneCovering letter.OthersCovering letter.
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Covering letter.
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Annual Turnover CertificateTrueTechnical Bid
Company Registration CertificateFalseTechnical Bid
Reserved Category CertificateFalseTechnical Bid
Small Scale Industries CertificateFalseTechnical Bid
Work done certificateTrueTechnical Bid
key and critical equipment LISTTrueTechnical Bid
Income Tax returns & PAN no.TrueTechnical Bid
Pre-qualification certificate issued by KHBTrueTechnical Bid
GST clearance certificateTrueTechnical Bid
Credit lines/ letter of credit/Bankers certificateTrueTechnical Bid
Assessed available tender capacity calculationTrueTechnical Bid
Electrical licenseTrueTechnical Bid
Work done certificate with quantitiesTrueTechnical Bid
tenderWorkLocationList
tenderAddress
createdTs1718028943000
version0
createdDateNone
modifiedDateNone
blockNumberCAUVERY BHAVAN 3RD FLOOR
streetNone
cityBengaluru
stateKarnataka
pin560009
tenderRecallDTONone