3247302 | 112369 | None | code01 | Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. In area of light jungle | ha | 173349.0 | 173349.0 | 0.02 | False | None | None | False | None | False | 3466.98 | 0 |
3247303 | 112369 | None | code02 | Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. | Cum | 66.95 | 66.95 | 53.09 | False | None | None | False | None | False | 3554.3755 | 0 |
3247304 | 112369 | None | code03 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. In all kinds of soils Depth upto 3 m | Cum | 75.19 | 75.19 | 162.59 | False | None | None | False | None | False | 12225.1421 | 0 |
3247305 | 112369 | None | code04 | In ordinary/soft rock without blasting, Depth exceeding 1.5 m, but not exceeding 3 m | Cum | 280.16 | 280.16 | 9.03 | False | None | None | False | None | False | 2529.8448 | 0 |
3247306 | 112369 | None | code05 | Earth work excavation for FOUNDATION by Mechanical means depth
upto 1.50m, as per drawing and technical specifications, including
setting out, shoring, strutting, barricading, caution lights, including cost
of explosives, dressing of excavated surfaces, disposing off or levelling
the excavated stuff or sorting & stacking the selected stuff for reuse
in a radius of 50 m and lift upto 1.5 m including cost of labour, blasting
materials, tools, usage of Machinery & all other appurtenaces required
to complete the work In Hard Rock ( requiring blasting) Depth upto 1.50m | Cum | 431.57 | 431.57 | 9.03 | False | None | None | False | None | False | 3897.0771 | 0 |
3247307 | 112369 | None | code06 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | Cum | 210.12 | 210.12 | 162.59 | False | None | None | False | None | False | 34163.4108 | 0 |
3247308 | 112369 | None | code07 | Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/sqm including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications. | Sqm | 97.85 | 97.85 | 175.38 | False | None | None | False | None | False | 17160.933 | 0 |
3247309 | 112369 | None | code08 | Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. | Cum | 414.06 | 414.06 | 37.68 | False | None | None | False | None | False | 15601.7808 | 0 |
3247310 | 112369 | None | code09 | Providing and laying in position plain cement concrete for levelling
course for all works in foundation. The granite/trap/basalt crushed
graded coarse aggregates and fine aggregates as per relevant IS
Codes machine mixed, laid in layers not exceeding 150 mm thickness,
well compacted using plate vibrators, including all lead & lifts, cost of
all materials of quality, labour, Usage charges of machineries, curing,
and all the other appurtenances required to complete the work as per
technical specifications. (The cost of steel reinforcement & formwork
shall be paid separately)
Mix 1:3:6 (M10) Using 40 mm and down size graded crushed coarse
aggregates | Cum | 5720.62 | 5720.62 | 30.74 | False | None | None | False | None | False | 175851.8588 | 0 |
3247311 | 112369 | None | code10 | Providing and laying in position Reinforced cement concrete for all
Foundation works. The granite/trap/basalt crushed graded coarse
aggregates and fine aggregates as per relevant IS Codes machine
mixed with super plasticizers laid in finished layers, well compacted
using needle vibrators, including all lead & lifts, cost of all materials,
quality confirming to the requirements of relevant IS codes , labour,
Usage charges of machinery, curing and all the other appurtenances
required to complete the work as per technical specifications. (The cost
of steel reinforcement & formwork to be paid separately)
sqm5 Design Mix Using 20 mm and down size graded crushed coarse
aggregates consider 8% of finished rate of concrete for foundation upto plitnth shuttering (footing) | Cum | 6651.04 | 6651.04 | 69.0844 | False | None | None | False | None | False | 459483.107776 | 0 |
3247312 | 112369 | None | code11 | Providing and laying in position Reinforced cement concrete for all
Foundation works. The granite/trap/basalt crushed graded coarse
aggregates and fine aggregates as per relevant IS Codes machine
mixed with super plasticizers laid in finished layers, well compacted
using needle vibrators, including all lead & lifts, cost of all materials,
quality confirming to the requirements of relevant IS codes , labour,
Usage charges of machinery, curing and all the other appurtenances
required to complete the work as per technical specifications. (The cost
of steel reinforcement & formwork to be paid separately)
sqm5 Design Mix Using 20 mm and down size graded crushed coarse
aggregates consider 50% of finished rate of concrete for plinth beam shuttering | Cum | 9237.56 | 9237.56 | 14.63 | False | None | None | False | None | False | 135145.5028 | 0 |
3247313 | 112369 | None | code12 | Providing and laying in position Reinforced cement concrete for all
Super structures of building , Road works, Water works, Irrigation works
& super structure works of bridges upto 3.50 m height. The granite/
trap/basalt crushed graded coarse aggregates and fine aggregates
as per relevant IS Codes machine mixed with super plasticisers laid in
layers, well compacted using needle vibrators. The cost includes all
lead & lifts, cost of all materials, quality confirming to the requirements
of relevant IS codes , labour, Usage charges of machinery, curing and
all other appurtenances required to complete the work as per technical
specifications. (The cost of steel reinforcement, dowel bars & formwork
to be paid separately) consider 70% of finished rate of concrete for column shuttering | Cum | 10831.69 | 10831.69 | 8.42 | False | None | None | False | None | False | 91202.8298 | 0 |
3247314 | 112369 | None | code13 | Providing and laying in position Reinforced cement concrete for all
Super structures of building , Road works, Water works, Irrigation works
& super structure works of bridges upto 3.50 m height. The granite/
trap/basalt crushed graded coarse aggregates and fine aggregates
as per relevant IS Codes machine mixed with super plasticisers laid in
layers, well compacted using needle vibrators. The cost includes all
lead & lifts, cost of all materials, quality confirming to the requirements
of relevant IS codes , labour, Usage charges of machinery, curing and
all other appurtenances required to complete the work as per technical
specifications. (The cost of steel reinforcement, dowel bars & formwork
to be paid separately) consider 60% of finished rate of concrete for roof beam shuttering | Cum | 10194.53 | 10194.53 | 16.95 | False | None | None | False | None | False | 172797.2835 | 0 |
3247315 | 112369 | None | code14 | Providing and laying in position Reinforced cement concrete for all
Super structures of building , Road works, Water works, Irrigation works
& super structure works of bridges upto 3.50 m height. The granite/
trap/basalt crushed graded coarse aggregates and fine aggregates
as per relevant IS Codes machine mixed with super plasticisers laid in
layers, well compacted using needle vibrators. The cost includes all
lead & lifts, cost of all materials, quality confirming to the requirements
of relevant IS codes , labour, Usage charges of machinery, curing and
all other appurtenances required to complete the work as per technical
specifications. (The cost of steel reinforcement, dowel bars & formwork
to be paid separately) consider 50% of finished rate of concrete for roof slab shuttering | Cum | 9557.37 | 9557.37 | 26.31 | False | None | None | False | None | False | 251454.4047 | 0 |
3247316 | 112369 | None | code15 | Providing and laying in position Reinforced cement concrete for all
Super structures of building , Road works, Water works, Irrigation works
& super structure works of bridges upto 3.50 m height. The granite/
trap/basalt crushed graded coarse aggregates and fine aggregates
as per relevant IS Codes machine mixed with super plasticisers laid in
layers, well compacted using needle vibrators. The cost includes all
lead & lifts, cost of all materials, quality confirming to the requirements
of relevant IS codes , labour, Usage charges of machinery, curing and
all other appurtenances required to complete the work as per technical
specifications. (The cost of steel reinforcement, dowel bars & formwork
to be paid separately)consider 60% of finished rate of concrete for linte lshuttering | Cum | 10194.53 | 10194.53 | 1.5 | False | None | None | False | None | False | 15291.795 | 0 |
3247317 | 112369 | None | code16 | Providing and laying in position Reinforced cement concrete for all
Super structures of building , Road works, Water works, Irrigation works
& super structure works of bridges upto 3.50 m height. The granite/
trap/basalt crushed graded coarse aggregates and fine aggregates
as per relevant IS Codes machine mixed with super plasticisers laid in
layers, well compacted using needle vibrators. The cost includes all
lead & lifts, cost of all materials, quality confirming to the requirements
of relevant IS codes , labour, Usage charges of machinery, curing and
all other appurtenances required to complete the work as per technical
specifications. (The cost of steel reinforcement, dowel bars & formwork
to be paid separately)consider 45% of finished rate of concrete for chejja shuttering | Cum | 9238.79 | 9238.79 | 0.38 | False | None | None | False | None | False | 3510.7402 | 0 |
3247318 | 112369 | None | code17 | Providing Thermo-Mechanically Treated bars of grade Fe-550D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) | Kg | 94.76 | 94.76 | 13939.2 | False | None | None | False | None | False | 1320878.592 | 0 |
3247319 | 112369 | None | code18 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/cum and minimum compressive strength of 4.00 N/msqm conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. | Sqm | 1231.88 | 1231.88 | 202.4 | False | None | None | False | None | False | 249332.512 | 0 |
3247320 | 112369 | None | code19 | Providing Red Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. | Cum | 63451.09 | 63451.09 | 0.18 | False | None | None | False | None | False | 11421.1962 | 0 |
3247321 | 112369 | None | code20 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 35 mm thick both side commercial | Sqm | 3032.32 | 3032.32 | 3.6 | False | None | None | False | None | False | 10916.352 | 0 |
3247322 | 112369 | None | code21 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications | Nos | 1525.43 | 1525.43 | 1.0 | False | None | None | False | None | False | 1525.43 | 0 |
3247323 | 112369 | None | code22 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size - 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) | Sqm | 7457.2 | 7457.2 | 16.2 | False | None | None | False | None | False | 120806.64 | 0 |
3247324 | 112369 | None | code23 | Providing 12 mm cement plaster finished with a floating coat of neat
cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including
rounding off corners wherever required smooth rendering, providing and
removing scaffolding, including cost of materials, labour, curing complete
as per specifications and as per directions of Engineer-in-charge. | Sqm | 269.86 | 269.86 | 254.54 | False | None | None | False | None | False | 68690.1644 | 0 |
3247325 | 112369 | None | code24 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 316.21 | 316.21 | 359.5 | False | None | None | False | None | False | 113677.495 | 0 |
3247326 | 112369 | None | code25 | Finishing with Epoxy paint (two coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete. On steel work including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Enginer-in-charge. | Sqm | 142.14 | 142.14 | 13.5 | False | None | None | False | None | False | 1918.89 | 0 |
3247327 | 112369 | None | code26 | Painting wood work with Deluxe Multi Surface Paint of required shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @0.75 ltr/10 m² of approved brand and manufacture to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 108.15 | 108.15 | 4.68 | False | None | None | False | None | False | 506.142 | 0 |
3247328 | 112369 | None | code27 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Special primer applied @ 0.75 ltr /10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 121.54 | 121.54 | 425.48 | False | None | None | False | None | False | 51712.8392 | 0 |
3247329 | 112369 | None | code28 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. | Sqm | 85.49 | 85.49 | 425.48 | False | None | None | False | None | False | 36374.2852 | 0 |
3247330 | 112369 | None | code29 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two coats applied @ 1.43 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 135.96 | 135.96 | 358.15 | False | None | None | False | None | False | 48694.074 | 0 |
3247331 | 112369 | None | code30 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete. | Sqm | 1135.06 | 1135.06 | 127.88 | False | None | None | False | None | False | 145151.4728 | 0 |
3247332 | 112369 | None | code31 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent. | Sqm | 2956.1 | 2956.1 | 43.16 | False | None | None | False | None | False | 127585.276 | 0 |
3247333 | 112369 | None | code32 | Providing Lath plaster with cement mortar 1:3 5cm thick with 6mm dia mild steel bars at 20cms. C to c both horizontally and vertically fixing chicken mesh for drop chejjas, facia, backing to cup board including cost of all materials, labour, providing and removing form work HOM of machineries, curing, complete as per specification. | Sqm | 1210.25 | 1210.25 | 7.11 | False | None | None | False | None | False | 8604.8775 | 0 |
3247334 | 112369 | None | code33 | Providing and laying in position Reinforced cement concrete for all
Sub structures of building, Irrigation works, Sub structure works of
bridges, Drain works & other parallel works from 0.50m to 3.50 m
height. The granite/trap/basalt crushed graded coarse aggregates and
fine aggregates as per relevant IS Codes machine mixed with super
plasticisers, laid in layers, well compacted using needle vibrators,
providing weep holes wherever necesary, including all lead & lifts, cost
of all materials of quality, confirming to the requirements of relevant
IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical
specifications. (The cost of steel reinforcement & formwork to be paid
separately) | Cum | 6056.4 | 6056.4 | 0.8 | False | None | None | False | None | False | 4845.12 | 0 |
3247335 | 112369 | None | code34 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding | Kg | 149.35 | 149.35 | 349.65 | False | None | None | False | None | False | 52220.2275 | 0 |
3247336 | 112369 | None | code35 | Providing and supplying crystalline integral concrete waterproofing
admixture that waterproofs concrete by forming crystals deep in
the pores, capillaries and microcracks of the concrete, self-seal
waterproofing compound to bridge shrinkage cracks upto 0.5mm in
width & resist hydro-static pressure upto 16bar for both positive &
negative pressure confirming to DIN 1048 part 5 for 56% reduction in
depth of penetration against control, resistance to chloride penetration
confirming to ASTM C 1202 with 64% improvement against control &
protecting steel re-inforcement against corrosion mixed @ 1% by weight
of cementitious content in concrete. ie., integral crystaline waterproofing
admix @ 0.5 kg/bag of cement. (For calculation purpose 320 kg of
Cement for M-20 grade of Concrete is considered in the analysis) | Sqm | 579.89 | 579.89 | 175.38 | False | None | None | False | None | False | 101701.1082 | 0 |
3247337 | 112369 | None | code36 | ELECTRICAL WORKS : Open Conduit System Supplying heavy gauge PVC conduit pipe……mm dia ......mm thick conforming to IS 2509 with suitable size bends, junction boxes,adhesive paste etc.,and fixing using inverted wood plugs in case of RCC ceiling and RCC wall stone structure or rawl plugs in case of brick walls and cement plastering damaged portion using heavy gauge saddles at an interval of 700mm using NF screws.(KPWD SR 2021-22) /I.No.113/Pg.No.2) 32 mm dia 2.5mm thick | m | 100.0 | 100.0 | 100.0 | False | None | None | False | None | False | 10000.0 | 0 |
3247338 | 112369 | None | code37 | Supplying heavy gauge PVC conduit pipe……mm dia ......mm thick conforming to IS 2509 with suitable size bends,metal/PVC junction boxes,adhesive paste etc.,and running before slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18 SWG GI fish wire wherever necessary.(KPWD SR 2021-22) /I.No.121,122,123). 25 mm dia 2mm thick | m | 70.0 | 70.0 | 60.0 | False | None | None | False | None | False | 4200.0 | 0 |
3247339 | 112369 | None | code38 | Supplying heavy gauge PVC conduit pipe……mm dia ......mm thick conforming to IS 2509 with suitable size bends,metal/PVC junction boxes,adhesive paste etc.,and running before slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18 SWG GI fish wire wherever necessary.(KPWD SR 2021-22) /I.No.121,122,123). 20 mm dia 2mm thick | m | 61.0 | 61.0 | 50.0 | False | None | None | False | None | False | 3050.0 | 0 |
3247340 | 112369 | None | code39 | Supplying heavy gauge PVC conduit pipe……mm dia ......mm thick conforming to IS 2509 with suitable size bends,metal/PVC junction boxes,adhesive paste etc.,and running before slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18 SWG GI fish wire wherever necessary.(KPWD SR 2021-22) /I.No.121,122,123). 32 mm dia 2.5mm thick | m | 93.0 | 93.0 | 50.0 | False | None | None | False | None | False | 4650.0 | 0 |
3247341 | 112369 | None | code40 | Supplying heavy gauge PVC conduit pipe……mm dia ......mm thick with suitable size bends,metal junction boxes,adhesive paste etc.,by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary.(KPWD SR 2021-22/I.No.131,132 ) 25 mm dia 2mm thick | m | 80.0 | 80.0 | 100.0 | False | None | None | False | None | False | 8000.0 | 0 |
3247342 | 112369 | None | code41 | Supplying heavy gauge PVC conduit pipe……mm dia ......mm thick with suitable size bends,metal junction boxes,adhesive paste etc.,by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary.(KPWD SR 2021-22/I.No.131,132 ) 20 mm dia 2mm thick | m | 75.0 | 75.0 | 80.0 | False | None | None | False | None | False | 6000.0 | 0 |
3247343 | 112369 | None | code42 | Supplying and flush mounting powder coated / galvanised metal box suitable for mounting modular witch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/CC wall.(KPWD SR 2021-22/I.No.341,342,343,344,345). 1-3 Way | Each | 123.0 | 123.0 | 25.0 | False | None | None | False | None | False | 3075.0 | 0 |
3247344 | 112369 | None | code43 | Supplying and flush mounting powder coated / galvanised metal box suitable for mounting modular witch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/CC wall.(KPWD SR 2021-22/I.No.341,342,343,344,345). 4-5 Way | Each | 138.0 | 138.0 | 8.0 | False | None | None | False | None | False | 1104.0 | 0 |
3247345 | 112369 | None | code44 | Supplying and flush mounting powder coated / galvanised metal box suitable for mounting modular witch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/CC wall.(KPWD SR 2021-22/I.No.341,342,343,344,345).6 Way | Each | 212.0 | 212.0 | 12.0 | False | None | None | False | None | False | 2544.0 | 0 |
3247346 | 112369 | None | code45 | Supplying and flush mounting powder coated / galvanised metal box suitable for mounting modular witch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/CC wall.(KPWD SR 2021-22/I.No.341,342,343,344,345). 8 Way | Each | 250.0 | 250.0 | 10.0 | False | None | None | False | None | False | 2500.0 | 0 |
3247347 | 112369 | None | code46 | Supplying and flush mounting powder coated / galvanised metal box suitable for mounting modular witch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/CC wall.(KPWD SR 2021-22/I.No.341,342,343,344,345). 12 Way | Each | 325.0 | 325.0 | 8.0 | False | None | None | False | None | False | 2600.0 | 0 |
3247348 | 112369 | None | code47 | Supplying and fixing superior quality modular switch mounting polycorbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.(KPWD 2021-22/I.No.351 to 355 /Pg.No.9). 1-3 Way | Each | 152.0 | 152.0 | 10.0 | False | None | None | False | None | False | 1520.0 | 0 |
3247349 | 112369 | None | code48 | Supplying and fixing superior quality modular switch mounting polycorbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.(KPWD 2021-22/I.No.351 to 355 /Pg.No.9).4 Way | Each | 175.0 | 175.0 | 8.0 | False | None | None | False | None | False | 1400.0 | 0 |
3247350 | 112369 | None | code49 | Supplying and fixing superior quality modular switch mounting polycorbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.(KPWD 2021-22/I.No.351 to 355 /Pg.No.9).6 Way | Each | 244.0 | 244.0 | 6.0 | False | None | None | False | None | False | 1464.0 | 0 |
3247351 | 112369 | None | code50 | Supplying and fixing superior quality modular switch mounting polycorbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.(KPWD 2021-22/I.No.351 to 355 /Pg.No.9).8 Way | Each | 302.0 | 302.0 | 4.0 | False | None | None | False | None | False | 1208.0 | 0 |
3247352 | 112369 | None | code51 | Supplying and fixing superior quality modular switch mounting polycorbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.(KPWD 2021-22/I.No.351 to 355 /Pg.No.9).12 Way | Each | 363.0 | 363.0 | 3.0 | False | None | None | False | None | False | 1089.0 | 0 |
3247353 | 112369 | None | code52 | Supplying 4 mm thick plastic sheet with necessary nitches for fixing switches regulators etc, and fixing on existing wooden / metal box using N.F screws.(KPWD SR 2021-22/I.No.3.8). | Sq CM | 0.29 | 0.29 | 8000.0 | False | None | None | False | None | False | 2320.0 | 0 |
3247354 | 112369 | None | code53 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS
multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the
other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.
.(KPWD SR 2021-22 /I.No.221 to 225). Short point upto 3 Mtr from the tapping point to outlet via switch box. | Each | 251.0 | 251.0 | 10.0 | False | None | None | False | None | False | 2510.0 | 0 |
3247355 | 112369 | None | code54 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS
multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the
other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.
.(KPWD SR 2021-22 /I.No.221 to 225).Medium point above 3 Mtr upto 6 mtr from tapping point to outlet via switch box. | Each | 361.0 | 361.0 | 3.0 | False | None | None | False | None | False | 1083.0 | 0 |
3247356 | 112369 | None | code55 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS
multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the
other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.
.(KPWD SR 2021-22 /I.No.221 to 225). Long point above 6 Mtr upto 10 Mtr. tapping point from outlet via switch box. | Each | 542.0 | 542.0 | 6.0 | False | None | None | False | None | False | 3252.0 | 0 |
3247357 | 112369 | None | code56 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS
multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the
other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.
.(KPWD SR 2021-22 /I.No.221 to 225). Two out let in a row, above 3 meter upto 6 meter from tapping point to outlet via switch | Each | 671.0 | 671.0 | 2.0 | False | None | None | False | None | False | 1342.0 | 0 |
3247358 | 112369 | None | code57 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS
multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the
other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.
.(KPWD SR 2021-22 /I.No.221 to 225). Three out let in a row, above 6 meter upto 10 meter from tapping point to outlet via switch | Each | 979.0 | 979.0 | 8.0 | False | None | None | False | None | False | 7832.0 | 0 |
3247359 | 112369 | None | code58 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multi-strand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & cofirming to latest amendments.(KPWD SR2021-22/I.No.232 to 237 /Pg.No.5&6). 1.5 sqmm | m | 26.0 | 26.0 | 250.0 | False | None | None | False | None | False | 6500.0 | 0 |
3247360 | 112369 | None | code59 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multi-strand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & cofirming to latest amendments.(KPWD SR2021-22/I.No.232 to 237 /Pg.No.5&6). 2.5 sqmm | m | 40.0 | 40.0 | 210.0 | False | None | None | False | None | False | 8400.0 | 0 |
3247361 | 112369 | None | code60 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multi-strand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & cofirming to latest amendments.(KPWD SR2021-22/I.No.232 to 237 /Pg.No.5&6). 4 sqmm | m | 59.0 | 59.0 | 120.0 | False | None | None | False | None | False | 7080.0 | 0 |
3247362 | 112369 | None | code61 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multi-strand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & cofirming to latest amendments.(KPWD SR2021-22/I.No.232 to 237 /Pg.No.5&6). 6 sqmm | m | 87.0 | 87.0 | 40.0 | False | None | None | False | None | False | 3480.0 | 0 |
3247363 | 112369 | None | code62 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multi-strand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & cofirming to latest amendments.(KPWD SR2021-22/I.No.232 to 237 /Pg.No.5&6). 10 sqmm | m | 157.0 | 157.0 | 50.0 | False | None | None | False | None | False | 7850.0 | 0 |
3247364 | 112369 | None | code63 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multi-strand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & cofirming to latest amendments.(KPWD SR2021-22/I.No.232 to 237 /Pg.No.5&6). 16 sqmm | m | 318.0 | 318.0 | 20.0 | False | None | None | False | None | False | 6360.0 | 0 |
3247365 | 112369 | None | code64 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.
.(KPWD SR 2021-22/I.No.361,362,363,364,368,3611,3612). 6 Amps One Way switch | Each | 88.0 | 88.0 | 6.0 | False | None | None | False | None | False | 528.0 | 0 |
3247366 | 112369 | None | code65 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.
.(KPWD SR 2021-22/I.No.361,362,363,364,368,3611,3612). 6 Amps Two Way switch | Each | 152.0 | 152.0 | 4.0 | False | None | None | False | None | False | 608.0 | 0 |
3247367 | 112369 | None | code66 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.
.(KPWD SR 2021-22/I.No.361,362,363,364,368,3611,3612). 6 Amps 3 Way socket | Each | 162.0 | 162.0 | 10.0 | False | None | None | False | None | False | 1620.0 | 0 |
3247368 | 112369 | None | code67 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.
.(KPWD SR 2021-22/I.No.361,362,363,364,368,3611,3612). Stepped Fan Regulator | Each | 313.0 | 313.0 | 2.0 | False | None | None | False | None | False | 626.0 | 0 |
3247369 | 112369 | None | code68 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.
.(KPWD SR 2021-22/I.No.361,362,363,364,368,3611,3612). 16 Amps One Way switch | Each | 249.0 | 249.0 | 4.0 | False | None | None | False | None | False | 996.0 | 0 |
3247370 | 112369 | None | code69 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.
.(KPWD SR 2021-22/I.No.361,362,363,364,368,3611,3612). 6/16 Amps universel socket | Each | 249.0 | 249.0 | 2.0 | False | None | None | False | None | False | 498.0 | 0 |
3247371 | 112369 | None | code70 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.
.(KPWD SR 2021-22/I.No.361,362,363,364,368,3611,3612). Telephone Socket - RJ 11 | Each | 147.0 | 147.0 | 3.0 | False | None | None | False | None | False | 441.0 | 0 |
3247372 | 112369 | None | code71 | Supply and fixing of I/O Socket with back box | Each | 405.0 | 405.0 | 2.0 | False | None | None | False | None | False | 810.0 | 0 |
3247373 | 112369 | None | code72 | 16 port 10/100 Switch | Each | 2809.0 | 2809.0 | 1.0 | False | None | None | False | None | False | 2809.0 | 0 |
3247374 | 112369 | None | code73 | Supplying & Fixing of switch mounting rack with power manager & Cable manager. 6U with 450mm depth (I.NO:842). | Each | 4657.0 | 4657.0 | 1.0 | False | None | None | False | None | False | 4657.0 | 0 |
3247375 | 112369 | None | code74 | Supplying & Fixing of Patch panel for LAN cabling 16 Port 10/100 patch pane (I.NO:8123) | Each | 3292.0 | 3292.0 | 1.0 | False | None | None | False | None | False | 3292.0 | 0 |
3247376 | 112369 | None | code75 | Supplying & Fixing of …Mtrs Cat 6 Patch Cable 2mtr (I.NO:8.11.2) | Each | 286.0 | 286.0 | 2.0 | False | None | None | False | None | False | 572.0 | 0 |
3247377 | 112369 | None | code76 | Supplying & Fixing of …Mtrs Cat 6 Patch Cable 2mtr(I.NO:811.3) | Each | 369.0 | 369.0 | 2.0 | False | None | None | False | None | False | 738.0 | 0 |
3247378 | 112369 | None | code77 | Supplying and Fixing regular MCB distribution board on wall / wood board / flush mounting using required clamps, bolts, nuts, etc., with provision for fixing suitable type capacity MCB's single phase / Three phase double door with powder coated painting, made out of 14 SWG MS enclosure, complete.(KPWD SR 2021-22/I.No.51811,51812,518,135,189). 6 Way TPN Distribution Board | Each | 3053.0 | 3053.0 | 1.0 | False | None | None | False | None | False | 3053.0 | 0 |
3247379 | 112369 | None | code78 | Supplying and Fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with short circuit breaking capacity of 10 kA and wiring complete as required confirming to IEC 60898.(KPWD SR 2021-22 /I.No.5171,5178,5179,5175). 6-32Amps SP | Each | 523.0 | 523.0 | 1.0 | False | None | None | False | None | False | 523.0 | 0 |
3247380 | 112369 | None | code79 | Supplying, fixing and wiring of earth electrode for grounding of lifts, Transformers DG Sets etc, using 40mm dia 2.9 mm thick 2.5 meter long GI pipe with GI nnel with mesh & suitable size reducer fixed on the top of the earth electrode. The funnel should be enclosed in a CC chamber of 400 X 400 X 400 mm with a cast iron cover. The earth electrode shall have staggered holes of 12 mm dia and the electrode should be covered 150 mm alround with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using bolts and nuts.(KPWD SR 2019-2020 /I.No.6.2/Pg.No.40). | No | 4150.0 | 4150.0 | 1.0 | False | None | None | False | None | False | 4150.0 | 0 |
3247381 | 112369 | None | code80 | Supplying and running of GI/Copper stripes for grounding connections, using necessary fixing materials as required.(KPWD SR 2019-2020 /I.No.6.3.1, 6.3.2 /Pg.No.40). a) 25 X 3 mm GI strip | m | 75.0 | 75.0 | 10.0 | False | None | None | False | None | False | 750.0 | 0 |
3247382 | 112369 | None | code81 | Supplying and running of GI/Copper stripes for grounding connections, using necessary fixing materials as required.(KPWD SR 2019-2020 /I.No.6.3.1, 6.3.2 /Pg.No.40). a) 25 X 6 mm GI Strip | m | 115.0 | 115.0 | 15.0 | False | None | None | False | None | False | 1725.0 | 0 |
3247383 | 112369 | None | code82 | Supplying and running GI/Copper conductor for grounding and ( along with other wires in conduit system of wiring ) using necessary suitable size clamps, Nails, gattas/Spacers etc,.(KPWD SR 2019-2020 /I.No.6.18.6, 6.18.5, 6.18.3, 6.18.2 /Pg.No.43-44). a) 8 SWG Copper wire | m | 105.0 | 105.0 | 20.0 | False | None | None | False | None | False | 2100.0 | 0 |
3247384 | 112369 | None | code83 | Supplying and running GI/Copper conductor for grounding and ( along with other wires in conduit system of wiring ) using necessary suitable size clamps, Nails, gattas/Spacers etc,.(KPWD SR 2019-2020 /I.No.6.18.6, 6.18.5, 6.18.3, 6.18.2 /Pg.No.43-44). b) 10 SWG Copper wire | m | 68.0 | 68.0 | 10.0 | False | None | None | False | None | False | 680.0 | 0 |
3247385 | 112369 | None | code84 | cSupplying and running GI/Copper conductor for grounding and ( along with other wires in conduit system of wiring ) using necessary suitable size clamps, Nails, gattas/Spacers etc,.(KPWD SR 2019-2020 /I.No.6.18.6, 6.18.5, 6.18.3, 6.18.2 /Pg.No.43-44). ) 8 SWG GI wire | m | 19.0 | 19.0 | 20.0 | False | None | None | False | None | False | 380.0 | 0 |
3247386 | 112369 | None | code85 | Supplying and running GI/Copper conductor for grounding and ( along with other wires in conduit system of wiring ) using necessary suitable size clamps, Nails, gattas/Spacers etc,.(KPWD SR 2019-2020 /I.No.6.18.6, 6.18.5, 6.18.3, 6.18.2 /Pg.No.43-44). ) 10 SWG GI wire | m | 15.0 | 15.0 | 20.0 | False | None | None | False | None | False | 300.0 | 0 |
3247387 | 112369 | None | code86 | Supplying and fixing 2mm thick perforated cable GI tray with on existing MS angle support using necessary GI bolts/nuts and washer or welding as required.
a. 450 X 50 mm | m | 818.0 | 818.0 | 1.0 | False | None | None | False | None | False | 818.0 | 0 |
3247388 | 112369 | None | code87 | BUILDING LIGHTNING PROTECTION SYSTEM Design & Supply of Air Termination Supply of Gravin conventional Type GI Lightning protection system.. | Nos | 4000.0 | 4000.0 | 1.0 | False | None | None | False | None | False | 4000.0 | 0 |
3247389 | 112369 | None | code88 | Supporting Pole & stay arrangement Supply of Gravin 2.5mtr MAST. | Nos | 4500.0 | 4500.0 | 1.0 | False | None | None | False | None | False | 4500.0 | 0 |
3247390 | 112369 | None | code89 | Supplying of ......feet - PVC Batten with integrated LED tube .....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI greater than 80. Power Input: 220-240V @ 50/60Hz & Power factor greater than 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fighting. | Each | 496.0 | 496.0 | 4.0 | False | None | None | False | None | False | 1984.0 | 0 |
3247391 | 112369 | None | code90 | Supplying of ......feet - PVC Batten with integrated LED tube .....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI greater than 80. Power Input: 220-240V @ 50/60Hz & Power factor greater than 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fighting. | Each | 740.0 | 740.0 | 4.0 | False | None | None | False | None | False | 2960.0 | 0 |
3247392 | 112369 | None | code91 | Supplying of ......feet - PVC Batten with integrated LED tube .....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI greater than 80. Power Input: 220-240V @ 50/60Hz & Power factor greater than 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fighting. | Each | 1197.0 | 1197.0 | 2.0 | False | None | None | False | None | False | 2394.0 | 0 |
3247393 | 112369 | None | code92 | Fixing all types and capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafter / griders using 23/0.0076" twin twisted PVC insulated wires, required no.s of round blocks and clamps.(KPWD SR 2021-22 /I.No.371,372 /Pg.No.79). a) On Wall / Ceiling / Rafter / Griders | Each | 119.0 | 119.0 | 2.0 | False | None | None | False | None | False | 238.0 | 0 |
3247394 | 112369 | None | code93 | Fixing all types and capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafter / griders using 23/0.0076" twin twisted PVC insulated wires, required no.s of round blocks and clamps.(KPWD SR 2021-22 /I.No.371,372 /Pg.No.79). b) Using necessary length of G.I. Chain | Each | 253.0 | 253.0 | 6.0 | False | None | None | False | None | False | 1518.0 | 0 |
3247395 | 112369 | None | code94 | Supplying of recess mounting non integral type ........LED ...... W luminaire comprising of pressure decast/extruded aluminium housing, with spring loaded fase ceiling clamps, Power LEDs with CCT 6500 degree K, CRI greater than 70%. efficacy
greater than 100 lumen per watt, 120degree beam spread, life greater than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level. LEDs
are driven by HF electronic driver integrated in a separate control gear assembly., with PF greater than 0.95, power loss should lesser than 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, , THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/ CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. LED modular down light | Each | 2869.0 | 2869.0 | 2.0 | False | None | None | False | None | False | 5738.0 | 0 |
3247396 | 112369 | None | code95 | Supplying of recess mounting non integral type ........LED ...... W luminaire comprising of pressure decast/extruded aluminium housing, with spring loaded fase ceiling clamps, Power LEDs with CCT 6500 degree K, CRI greater than 70%. efficacy
greater than 100 lumen per watt, 120degree beam spread, life greater than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level. LEDs
are driven by HF electronic driver integrated in a separate control gear assembly., with PF greater than 0.95, power loss should lesser than 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, , THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/ CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. LED modular down light | Each | 6086.0 | 6086.0 | 2.0 | False | None | None | False | None | False | 12172.0 | 0 |
3247397 | 112369 | None | code96 | Supply of round/square recess/surface mounted rolling type LED Down light with .......W GU 10 LED Lamp Rib Fabricated from Die cast aluminium with white powder
coated prewired to mains connector & has swiveling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI greater than 80. Power Input: 220-240V
@ 50/60Hz & Power factor greater than 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED Square or round down light | Each | 835.0 | 835.0 | 1.0 | False | None | None | False | None | False | 835.0 | 0 |
3247398 | 112369 | None | code97 | Supply of round/square recess/surface mounted rolling type LED Down light with .......W GU 10 LED Lamp Rib Fabricated from Die cast aluminium with white powder
coated prewired to mains connector & has swiveling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI greater than 80. Power Input: 220-240V
@ 50/60Hz & Power factor greater than 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED Square or round down light | Each | 1249.0 | 1249.0 | 2.0 | False | None | None | False | None | False | 2498.0 | 0 |
3247399 | 112369 | None | code98 | Fixing all types and capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafter / griders using 23/0.0076" twin twisted PVC insulated wires, required no.s of round blocks and clamps.(KPWD SR 2021-22 /I.No.1371 /Pg.No.79). a) On Wall / Ceiling / Rafter / Griders | Each | 119.0 | 119.0 | 6.0 | False | None | None | False | None | False | 714.0 | 0 |
3247400 | 112369 | None | code99 | Supply of round/square recess/surface mounted rolling type LED Down light with .......W GU 10 LED Lamp Rib Fabricated from Die cast aluminium with white powder
coated prewired to mains connector & has swiveling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI greater than 80. Power Input: 220-240V
@ 50/60Hz & Power factor greater than 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED Square or round down light(Mirror Light) | Each | 546.0 | 546.0 | 1.0 | False | None | None | False | None | False | 546.0 | 0 |
3247401 | 112369 | None | code100 | Supply of round/square recess/surface mounted rolling type LED Down light with .......W GU 10 LED Lamp Rib Fabricated from Die cast aluminium with white powder
coated prewired to mains connector & has swiveling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI greater than 80. Power Input: 220-240V
@ 50/60Hz & Power factor greater than 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED Square or round down light (Bulk head Light) | Each | 835.0 | 835.0 | 1.0 | False | None | None | False | None | False | 835.0 | 0 |
3247402 | 112369 | None | code101 | Fixing all types and capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafter / griders using 23/0.0076" twin twisted PVC insulated wires, required no.s of round blocks and clamps.(KPWD SR 2014-2015/I.No.17.7/Pg.No.108). a) On Wall / Ceiling / Rafter / Griders | Each | 119.0 | 119.0 | 10.0 | False | None | None | False | None | False | 1190.0 | 0 |
3247403 | 112369 | None | code102 | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system
48" Sweep (1200mm) Regular model | Each | 2085.0 | 2085.0 | 6.0 | False | None | None | False | None | False | 12510.0 | 0 |
3247404 | 112369 | None | code103 | Supplying wall mounting Fan suitable to operate at single-phase 230V AC supply . 400 mm Sweep | Each | 2838.0 | 2838.0 | 6.0 | False | None | None | False | None | False | 17028.0 | 0 |
3247405 | 112369 | None | code104 | Fixing a ceiling / wall mounting fan of all capacities and all types, with necessary clamps and 'S' hook made out of 15mm dia MS rod, with 5 amps. ceiling rose of approved quality with necessary length of 23 / 0.0076 inch PVC insulated twin
twisted wire of approved quality, mounted on a suitable size wooden board and wired. | Each | 281.0 | 281.0 | 1.0 | False | None | None | False | None | False | 281.0 | 0 |
3247406 | 112369 | None | code105 | a)Supplying exhaust fan of 1440 RPM of 300mm (12" ) size with bracket blades complete for light duty suitable to operate on 230v 50Hz , AC Supply… | Each | 1542.0 | 1542.0 | 1.0 | False | None | None | False | None | False | 1542.0 | 0 |
3247407 | 112369 | None | code106 | Fixing one exhaust fan after making a suitable nitch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 amps, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame. | Each | 702.0 | 702.0 | 1.0 | False | None | None | False | None | False | 702.0 | 0 |
3247408 | 112369 | None | code107 | Supplying PVC/GI flexible conduit pipe…mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an
interval of 300mm using NF screws and on either end of the pipe terminated completely. 20mm | m | 25.0 | 25.0 | 7.0 | False | None | None | False | None | False | 175.0 | 0 |
3247409 | 112369 | None | code108 | Supplying PVC/GI flexible conduit pipe…mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an
interval of 300mm using NF screws and on either end of the pipe terminated completely. 25mm | m | 31.0 | 31.0 | 12.0 | False | None | None | False | None | False | 372.0 | 0 |
3247410 | 112369 | None | code109 | Supplying PVC/GI flexible conduit pipe…mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an
interval of 300mm using NF screws and on either end of the pipe terminated completely. 32mm | m | 41.0 | 41.0 | 7.0 | False | None | None | False | None | False | 287.0 | 0 |
3247411 | 112369 | None | code110 | Supplying ......... amps rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with
necessary bolts, nuts and washers etc., complete.
a) 250 Amps 4 x 30 x 10 mm Aluminum strips . | m | 3078.0 | 3078.0 | 2.0 | False | None | None | False | None | False | 6156.0 | 0 |
3247412 | 112369 | None | code111 | Supplying ......... amps rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with
necessary bolts, nuts and washers etc., complete.
a) 100 Amps 4 x 30 x 6 mm Aluminum strips . | m | 2214.0 | 2214.0 | 1.0 | False | None | None | False | None | False | 2214.0 | 0 |
3247413 | 112369 | None | code112 | Supplying and fixing angle iron frame work fabricated out of M.S angle iron .. And M.S.flat .. With bolts , washers etc., and painted with 2 coats of red oxide and then two coats of approved paint . ) 40 x 40 x 6 mm . | m | 275.0 | 275.0 | 10.0 | False | None | None | False | None | False | 2750.0 | 0 |
3247414 | 112369 | None | code113 | bSupplying and fixing angle iron frame work fabricated out of M.S angle iron .. And M.S.flat .. With bolts , washers etc., and painted with 2 coats of red oxide and then two coats of approved paint . ) 50 x 50 x6 mm . | m | 356.0 | 356.0 | 10.0 | False | None | None | False | None | False | 3560.0 | 0 |
3247415 | 112369 | None | code114 | cSupplying and fixing angle iron frame work fabricated out of M.S angle iron .. And M.S.flat .. With bolts , washers etc., and painted with 2 coats of red oxide and then two coats of approved paint . ) 75 x75 x 6 mm . | m | 497.0 | 497.0 | 3.0 | False | None | None | False | None | False | 1491.0 | 0 |
3247416 | 112369 | None | code115 | Supplying and fixing angle iron frame work fabricated out of M.S angle iron .. And M.S.flat .. With bolts , washers etc., and painted with 2 coats of red oxide and then two coats of approved paint . d ) 50 x 100 x 50 x 6 mm C channel . | m | 680.0 | 680.0 | 2.0 | False | None | None | False | None | False | 1360.0 | 0 |
3247417 | 112369 | None | code116 | Fabricating supplying and mounting MS box made out …SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with
hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. a) 14 SWG | Sq CM | 0.43 | 0.43 | 4000.0 | False | None | None | False | None | False | 1720.0 | 0 |
3247418 | 112369 | None | code117 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required . 1.GI strip 25 x 6 mm | m | 115.0 | 115.0 | 3.0 | False | None | None | False | None | False | 345.0 | 0 |
3247419 | 112369 | None | code118 | Providing and fixing Alluminium fixtures like 1 no of Aldrops of size 300 x 16 mm, 2 no's of Tower bolts of size 200 x 12 mm, 100 mm length ss Hinges, 2nos of Handles of size 200 mm, 1 no of Door Stopper & 1 no of Door Bush of approved make and quality including cost and conveyance of all materials and as per the direction of EIC of work with all lead and lift and as directed by the Engineer in charge of works. | Nos | 807.7 | 807.7 | 1.0 | False | None | None | False | None | False | 807.7 | 0 |
3247420 | 112369 | None | code119 | Providing and fixing of class room ceramic magnetic with wooden frame gree board of size 10' x 4' including materialm labour charges, fixing, transportation complete as per site ingineer instruction | Nos | 12054.0 | 12054.0 | 1.0 | False | None | None | False | None | False | 12054.0 | 0 |