1717864195000 | 0 | None | None | Other Works | Construction Of Slab To Drain And Providing Power Connection To Clean Drinking Water Plant Along Doggalli Road Of SC/ST Colony In Kakkargolla Village In Davangere Taluk | 126483.96 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3252818 | 112667 | None | 2.1.6 V-I | Providing and laying in position cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:2:4 Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6555.15 | 6555.15 | 0.44 | False | None | None | False | None | False | 2884.266 | 0 | 3252819 | 112667 | None | 2.5.1 V-I | Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6961.5 | 6961.5 | 1.51 | False | None | None | False | None | False | 10511.865 | 0 | 3252820 | 112667 | None | 6.33 V-II | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. | Sqm | 1292.55 | 1292.55 | 3.36 | False | None | None | False | None | False | 4342.968 | 0 | 3252821 | 112667 | None | 1.9 V-I | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | Cum | 279.3 | 279.3 | 15.91 | False | None | None | False | None | False | 4443.663 | 0 | 3252822 | 112667 | None | 2.1.2 V-I | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates | Cum | 5947.2 | 5947.2 | 0.76 | False | None | None | False | None | False | 4519.872 | 0 | 3252823 | 112667 | None | 8.2.1 V-II | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 309.75 | 309.75 | 14.56 | False | None | None | False | None | False | 4509.96 | 0 | 3252824 | 112667 | None | 1.4.1 V-I | Earth work excavation by manual means for drains, canals, waste weir draft, approach channels, key trench, foundation of Buildings & Bridges and such similar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work | Cum | 254.1 | 254.1 | 11.81 | False | None | None | False | None | False | 3000.921 | 0 | 3252825 | 112667 | None | 13.50.6 V-II | Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for cold water supply including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 50 mm nominal dia Pipes | Rmtr | 405.3 | 405.3 | 40.0 | False | None | None | False | None | False | 16212.0 | 0 | 3252826 | 112667 | None | 10.1.4 V-II | Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own rangements for procuring water for testing) etc. complete For: PVC pipes 63mm dia., 6 kg/sqcm & class 3 | Mtr | 169.05 | 169.05 | 7.0 | False | None | None | False | None | False | 1183.35 | 0 | 3252827 | 112667 | None | 11.15.2 V-II | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using flats 30x6mm for diagonal braces and central cross piece including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Sqm | 4454.1 | 4454.1 | 1.89 | False | None | None | False | None | False | 8418.249 | 0 | 3252828 | 112667 | None | 8.33.1 V-II | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Special primer applied @ 0.75 ltr /10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 165.9 | 165.9 | 3.48 | False | None | None | False | None | False | 577.332 | 0 | 3252829 | 112667 | None | 2.11a V-I | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specificationAll other type of structures | Tonne | 82961.55 | 82961.55 | 0.0264 | False | None | None | False | None | False | 2190.18492 | 0 | 3252830 | 112667 | None | 8.40 V-II | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 120.75 | 120.75 | 3.78 | False | None | None | False | None | False | 456.435 | 0 | 3252831 | 112667 | None | 2.3.2 PWD ELE | Wiring for lighting/power circuit using one of PVC insulated 1100v grade,multistrand copper wire with low conducteer resistance single core in open or concealed system of wiring with specifiedIS-694. 1.5 SQM | Mtr | 26.0 | 26.0 | 20.0 | False | None | None | False | None | False | 520.0 | 0 | 3252832 | 112667 | None | 2.3.2 PWD ELE | Wiring for lighting/power circuit using one of PVC insulated 1100v grade,multistrand copper wire with low conducteer resistance single core in open or concealed system of wiring with specifiedIS-694. 1.5 SQM | Mtr | 63.0 | 63.0 | 25.0 | False | None | None | False | None | False | 1575.0 | 0 | 3252833 | 112667 | None | 13.11.5 V-V | Providing Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications, to work site as per necessary ammendments and nstructions of engineer incharge of work. For 3 HP etc. complete.3.00 HP - 90 LPM @ 66 m = 10 STG Outlet Dia - 2.00". | No | 28113.0 | 28113.0 | 1.0 | False | None | None | False | None | False | 28113.0 | 0 | 3252834 | 112667 | None | 13.50.6 V-II | Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for cold water supply including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 50 mm nominal dia Pipes | Mtr | 405.3 | 405.3 | 33.0 | False | None | None | False | None | False | 13374.9 | 0 | 3252835 | 112667 | None | 13.22.3 V-V | Supply and delivery at site Brand new best make PVC insulated cable of Flat 3 core (sheathed) of nominal cross sectional area as per IS 694-1990 with ISI Mark and as per its latest amendments.1x3x4 Sqm. | Mtr | 135.0 | 135.0 | 30.0 | False | None | None | False | None | False | 4050.0 | 0 | 3252836 | 112667 | None | 13.25.1 V-V | Supply and delivery at site of brand new best make non-return valve as per IS 778/1984 with ISI Mark and as per its latest amendmentsSize 50 mm. | No | 1250.0 | 1250.0 | 1.0 | False | None | None | False | None | False | 1250.0 | 0 | 3252837 | 112667 | None | 13.33 V-V | Labour charges for erection of indoor type panel board and meter board units with all necessary materials and labour tools and equipments including cement concrete for foundation/bed etc,complete as per specification, with testing of as per instructions of engineer incharge of work. | Job | 1350.0 | 1350.0 | 1.0 | False | None | None | False | None | False | 1350.0 | 0 | 3252838 | 112667 | None | 13.23.1 V-V | Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE:
1) DOL- Direct Online Starter
2) S-D- Star Delta Starter etc. complete.Upto 3 HP pumps. | Each | 6500.0 | 6500.0 | 1.0 | False | None | None | False | None | False | 6500.0 | 0 | 3252839 | 112667 | None | 13.32 V-V | Labour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all items including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges,tools and equipments etc., involved in the job as per specifications, with necessary tests as per specifications, with testing of as per instructions of engineer incharge of work. | Job | 6500.0 | 6500.0 | 1.0 | False | None | None | False | None | False | 6500.0 | 0 |
|