createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1717910362324
version3
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee2300.00
emd167500.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose21-06-2024 16:30:00
tenderQueryClose18-06-2024 16:30:00
technicalBidOpen24-06-2024 11:00:00
publishedDate10-06-2024 13:40:33
publishedByPostRDPR_EE_DIV_RCR
publishedByUserKPE14312 - VENKATESH GALAG
bidValidityPeriod90
noOfCalls1
preBidMeetingDateNone
preBidMeetingYnFalse
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonMd. Faiz Alam
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumberNone
mobileNumber9972094236
tenderSupplierListNone
tenderSchedule
createdTs1717910362430
version5
createdDateNone
modifiedDateNone
tenderNumberRDPR/2024-25/BD/WORK_INDENT5947
titleConstruction of Sindhanur MLA M.H.P. School Building and Equipment Required for Smart Class in Sindhanur Taluka of Raichur District. Under KKRDB for the year 2023-24
descriptionConstruction of Sindhanur MLA M.H.P. School Building and Equipment Required for Smart Class in Sindhanur Taluka of Raichur District. Under KKRDB for the year 2023-24
categoryWORKS
categoryTextWorks
ecv9182053.65
deptNameRural Development and Panchayat Raj Department
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnTrue
location963
locationNameRDPR Division Office Raichur
provisionalAmount11164000.0
groupOverheadTotalNone
fileNumberEE/PRED/RCR/KKRDB/2023-24/SINDHANUR
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17179103620000NoneNoneBuildingsConstruction of Sindhanur MLA M.H.P. School Building and Equipment Required for Smart Class in Sindhanur Taluka of Raichur District176121.57
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3252844112669None001Demolishing cement concrete manually/ by mechanical means including disposal of material to the appropriate disposal area as per direction of Engineer-in-chargeCum1746.151746.1549.92FalseNoneNoneFalseNoneFalse87167.8080
3252845112669None002Demolishing stone rubble masonry manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material to the appropriate disposal area as per direction of Engineerin-chargeCum1768.21768.22.7FalseNoneNoneFalseNoneFalse4774.140
3252846112669None003Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge.Nos1080.751080.7577.89FalseNoneNoneFalseNoneFalse84179.61750
17179103620000NoneNoneBuildingsGround Floor Building8284803.24
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3252847112670None001Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depthCum99.7599.7590.0FalseNoneNoneFalseNoneFalse8977.50
3252848112670None002Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m Note: Cost of De-watering upto 5 % of (A+B) may be added, where required assessment for dewatering shall be made as per site condition In all kinds of soils Depth upto 3 mCum107.1107.1458.991FalseNoneNoneFalseNoneFalse49157.93610
3252849112670None003Earth work excavation by manual means for drains,canals, waste weir draft, approach channels, key trench, foundation of Bridges and such similar works, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, excavated surface leveled and sides neatly dressed disposing off or leveling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work. Depth exceeding 1.5m, but not exceeding 3 mCum271.95271.9550.999FalseNoneNoneFalseNoneFalse13869.178050
3252850112670None004Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregatesCum6527.856527.8523.416FalseNoneNoneFalseNoneFalse152856.13560
3252851112670None005Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum6799.396799.39100.032FalseNoneNoneFalseNoneFalse680156.580480
3252852112670None006Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Column Upto Grond LevelCum11222.311222.36.752FalseNoneNoneFalseNoneFalse75772.96960
3252853112670None007Providing Coursed rubble masonry (first sort) with hard stone in foundation and plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)Cum6948.96948.988.183FalseNoneNoneFalseNoneFalse612774.84870
3252854112670None008Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)Cum6708.456708.4543.575FalseNoneNoneFalseNoneFalse292320.708750
3252855112670None009Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes finsishing concrete structure in line, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately))-M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum11834.5511834.5521.138FalseNoneNoneFalseNoneFalse250158.71790
3252856112670None010Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes finsishing concrete structure in line, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately))-M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Plinth BeamCum9958.739958.7319.691FalseNoneNoneFalseNoneFalse196097.352430
3252857112670None011Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes finsishing concrete structure in line, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately))-M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates For Lintel BeamCum11138.411138.45.313FalseNoneNoneFalseNoneFalse59178.31920
3252858112670None012Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes finsishing concrete structure in line, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately))-M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates For Roof BeamCum11138.411138.411.713FalseNoneNoneFalseNoneFalse130464.07920
3252859112670None013Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes finsishing concrete structure in line, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately))-M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Ground Level SalbCum10442.2510442.2579.397FalseNoneNoneFalseNoneFalse829083.323250
3252860112670None014Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes finsishing concrete structure in line, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately))-M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Ground Floor StaircaseCum10442.2510442.252.84FalseNoneNoneFalseNoneFalse29655.990
3252861112670None015Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes finsishing concrete structure in line, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately))-M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesChejja and RacksCum10094.1810094.181.296FalseNoneNoneFalseNoneFalse13082.057280
3252862112670None016Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.Kgs93929.8593929.8515.5212FalseNoneNoneFalseNoneFalse1457903.987820
3252863112670None017Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum279.3279.3189.609FalseNoneNoneFalseNoneFalse52957.79370
3252864112670None018Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work.Cum497.7497.7292.719FalseNoneNoneFalseNoneFalse145686.24630
3252865112670None019Flooring Providing and laying Cement concrete pavement with 1:2:4 for commercial & residential building floors, hardpaths, footpaths using 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size, including finishing complete as per Engineer incharge.Cum6999.36999.336.59FalseNoneNoneFalseNoneFalse256104.3870
3252866112670None020Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.Cum1375.51375.5366.863FalseNoneNoneFalseNoneFalse504620.05650
3252867112670None021Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregatesCum6527.856527.851.855FalseNoneNoneFalseNoneFalse12109.161750
3252868112670None022Inside Plastering Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm309.75309.75263.61FalseNoneNoneFalseNoneFalse81653.19750
3252869112670None023External plastering Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm389.55389.55528.908FalseNoneNoneFalseNoneFalse206036.11140
3252870112670None024Wall Putty Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.Sq105.0105.0751.475FalseNoneNoneFalseNoneFalse78904.8750
3252871112670None025Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm182.7182.7528.908FalseNoneNoneFalseNoneFalse96631.49160
3252872112670None026Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm143.85143.85751.475FalseNoneNoneFalseNoneFalse108099.678750
3252873112670None027Providing and laying Polished Sadarahalli Grey Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 20 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-ChargeSqm2189.252189.25515.157FalseNoneNoneFalseNoneFalse1127807.462250
3252874112670None028Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete.Sqm933.45933.4535.227FalseNoneNoneFalseNoneFalse32882.643150
3252875112670None029Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications.Sqm103755.75103755.750.49FalseNoneNoneFalseNoneFalse50840.31750
3252876112670None030Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications.Sqm1066.81066.89.0FalseNoneNoneFalseNoneFalse9601.20
3252877112670None031Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. 35 mm thick one side teak and one side commercialSqm4091.854091.8519.01FalseNoneNoneFalseNoneFalse77786.06850
3252878112670None032Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete :125mmSqm46.246.218.0FalseNoneNoneFalseNoneFalse831.60
3252879112670None033Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete :125x64x1.90mmSqm107.1107.140.0FalseNoneNoneFalseNoneFalse4284.00
3252880112670None034Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete :Sqm86.186.19.0FalseNoneNoneFalseNoneFalse774.90
3252881112670None035Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. completeSqm136.5136.536.0FalseNoneNoneFalseNoneFalse4914.00
3252882112670None0360220 Locking arrangementsSqm664.65664.659.0FalseNoneNoneFalseNoneFalse5981.850
3252883112670None037Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer including cost of materials ,labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Sqm8689.88689.87.2FalseNoneNoneFalseNoneFalse62566.560
3252884112670None038Providing & fixing of 2-track x 2-panel sliding windows made out of multi chamberedUPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having a overall size of 60mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm X 58mm with GI reinforcement of 1mm for the frame and 1.5 mm for the sash. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 2-2.5 mm. Maximum possible size 1819mm x 1819mm (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)Sqm5659.55659.545.0FalseNoneNoneFalseNoneFalse254677.50
3252885112670None039Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)Sqm6004.956004.9511.7FalseNoneNoneFalseNoneFalse70257.9150
3252886112670None040Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by weldingKg176.4176.4855.0FalseNoneNoneFalseNoneFalse150822.00
3252887112670None041Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. G.I. pipes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer in-ChargeSqm192.15192.1597.2FalseNoneNoneFalseNoneFalse18676.980
3252888112670None042Painting wood work with Deluxe Multi Surface Paint of required shade. Two coat applied @ 0.90L/10 m² over an under coat of primer applied @0.75 L/10 m² of approved brand and manufacture to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm144.9144.920.16FalseNoneNoneFalseNoneFalse2921.1840
3252889112670None043Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @ 0.80 ltr/10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (47/8.33.3/VOL-2)Sqm145.95145.9558.68FalseNoneNoneFalseNoneFalse8564.3460
3252890112670None044Lettering with black Japan paint of approved brand and manufacture to give an even shade including preparing the surface after thoroughly cleaning the surface to remove all dirt, dust and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-chargecm4.24.21500.0FalseNoneNoneFalseNoneFalse6300.00
17179103620000NoneNoneBuildingsFor Ground Floor Electrical work127865.93
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3252891112671None001Supplying heavy gauge PVC conduit pipe ……mm dia .mm thick confirming to IS 2509 with suitable size bends,metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 19/20 mm dia 2mm thickMtr66.066.0200.0FalseNoneNoneFalseNoneFalse13200.00
3252892112671None002Supplying heavy gauge PVC conduit pipe ……mm dia .mm thick confirming to IS 2509 with suitable size bends,metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 25mm dia 2mm thickMtr78.078.040.0FalseNoneNoneFalseNoneFalse3120.00
3252893112671None003Supplying and fixing sheet metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc.75x75x65mmEach106.0106.012.0FalseNoneNoneFalseNoneFalse1272.00
3252894112671None004Supplying and fixing sheet metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc.200x90x65mmEach179.0179.04.0FalseNoneNoneFalseNoneFalse716.00
3252895112671None005Supplying and fixing sheet metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc.180X90X65mmEach161.0161.03.0FalseNoneNoneFalseNoneFalse483.00
3252896112671None006Supplying and fixing PVC/metal conduit Deep junction box 19/20mm Deep Junction BoxEach49.049.015.0FalseNoneNoneFalseNoneFalse735.00
3252897112671None007Supplying and fixing PVC/metal conduit Deep junction box 25mm Deep Junction BoxEach56.056.04.0FalseNoneNoneFalseNoneFalse224.00
3252898112671None008Extra for Groove cutting in brick wall/CC floor to the suitable depth for concealing of Conduit/GI pipe and plastering, finishing upto wall surface complete.upto 50mm Conduit in Brick WallsMtr29.029.080.0FalseNoneNoneFalseNoneFalse2320.00
3252899112671None009Supplying And Fixing Metal Fan Box with Round Hook.Nos171.15171.1515.0FalseNoneNoneFalseNoneFalse2567.250
3252900112671None010Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. A Short piont up to 3 Mtr from tapping piont out let via switch.Point285.0285.012.0FalseNoneNoneFalseNoneFalse3420.00
3252901112671None011Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. A medium piont above 3Mtr to 6 Mtr from tapping piont out let via switch.Point394.0394.03.0FalseNoneNoneFalseNoneFalse1182.00
3252902112671None012Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5 SqmmMtr26.026.0200.0FalseNoneNoneFalseNoneFalse5200.00
3252903112671None013Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.5 SqmmMtr42.042.0100.0FalseNoneNoneFalseNoneFalse4200.00
3252904112671None014Supplying and fixing superior quality switch mounting poly carbonate plate with necessary supporting back plate with required nos of machine tools, bolts, nuts etc., complete on the existing metal/PVC box.1 to 3 ModuleEach137.0137.08.0FalseNoneNoneFalseNoneFalse1096.00
3252905112671None015Supplying and fixing superior quality switch mounting poly carbonate plate with necessary supporting back plate with required nos of machine tools, bolts, nuts etc., complete on the existing metal/PVC box.4 ModuleEach175.0175.05.0FalseNoneNoneFalseNoneFalse875.00
3252906112671None016Supplying and fixing superior quality switch mounting poly carbonate plate with necessary supporting back plate with required nos of machine tools, bolts, nuts etc., complete on the existing metal/PVC box.1 to 8 ModuleEach234.0234.03.0FalseNoneNoneFalseNoneFalse702.00
3252907112671None017Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.For 6Amps one wayEach102.0102.013.0FalseNoneNoneFalseNoneFalse1326.00
3252908112671None018Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.For Stepped fan regulatorEach313.0313.05.0FalseNoneNoneFalseNoneFalse1565.00
3252909112671None019Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.For 16Amps one way switchEach177.0177.05.0FalseNoneNoneFalseNoneFalse885.00
3252910112671None020Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.For 32Amps DP switchEach182.0182.02.0FalseNoneNoneFalseNoneFalse364.00
3252911112671None02132Amps DP switchSupplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. For 6/16Amps universal socketEach156.0156.02.0FalseNoneNoneFalseNoneFalse312.00
3252912112671None02232Amps DP switchSupplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. For TV/Telephone socketEach79.079.02.0FalseNoneNoneFalseNoneFalse158.00
3252913112671None023Supplying and fixing 32A security and energy saving DPswitch with key tag suitable to operate on 230 V, 50Hz AC supply & completely wired on existing box.Each646.0646.01.0FalseNoneNoneFalseNoneFalse646.00
3252914112671None024Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. For 6-32 Amps SP1 * 6 Reels415.0415.01.0FalseNoneNoneFalseNoneFalse415.00
3252915112671None025Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. For 6-32 Amps DPEach739.0739.01.0FalseNoneNoneFalseNoneFalse739.00
3252916112671None026Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40mm dia 2.90mm thick GI pipe 2.5 mtr long buried in a pit … The pit should be filled with equal proportion of salt and charcoal 150mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per ISI specification 7.3.3. of IS 732 using 12mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm diaNo3149.683149.681.0FalseNoneNoneFalseNoneFalse3149.680
3252917112671None027Supplying of .feet - PVC Batten with integrated LED tube .W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.Each690.0690.020.0FalseNoneNoneFalseNoneFalse13800.00
3252918112671None028Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps.Each122.0122.05.0FalseNoneNoneFalseNoneFalse610.00
3252919112671None029Fixing all types and all capacities of 1'x4' / 2'x2' LED Light fittings indoor on the wall / ceiling / rafters / girders with necessary supporting frame, using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps.Each490.0490.020.0FalseNoneNoneFalseNoneFalse9800.00
3252920112671None030Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts,50 cycles. Single phase AC supply conforming to ISS-3741979 and with double ball bearing system.Each2984.02984.016.0FalseNoneNoneFalseNoneFalse47744.00
3252921112671None031Fixingaceiling /wallmounting fanof all capacities andall types,withnecessaryclampsand S hookmadeoutof15mmdiaMSrod, with5A. ceiling roseofapproved qualitywithnecessarylengthof 23/0.0076inchPVCinsulatedtwintwistedwireofapprovedquality, mounted on a suitable size wooden board and wired.Each315.0315.016.0FalseNoneNoneFalseNoneFalse5040.00
17179103620000NoneNoneBuildingsFor Water supply Work67024.04
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3252922112672None001Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tankLtr9.459.451000.0FalseNoneNoneFalseNoneFalse9450.00
3252923112672None002Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for cold water supply including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External workRmtr173.72173.72150.0FalseNoneNoneFalseNoneFalse26058.00
3252924112672None003Providing and fixing brass bib cock of approved quality : 20 mm nominal boreNos308.05308.058.0FalseNoneNoneFalseNoneFalse2464.40
3252925112672None004Providing and fixing Monoblock Pump 1/2 hp Low speed.Nos9090.09090.03.0FalseNoneNoneFalseNoneFalse27270.00
3252926112672None005Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISSPVC pipes 90mm dia., 6 kg/sqcmm296.94296.946.0FalseNoneNoneFalseNoneFalse1781.640
17179103620000NoneNoneBuildingsFor Borewell Work126238.87
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3252927112673None001Geophysical investigation at site for sinking borewells for supplying drinking water to the habitation either through the Hand Pump MWS or P.W.S.S, by vertical electrical sounding by adopting Venner or Schlumbergers’s method, including reconnaissance survey of geological formation. Geophysical investigation of existing ground water in the vicinity, its quality, quantity and acceptability of the users, indicating the location of the site, recommended depth of casing pipe required to seal the top unconsolidated formation including an extra depth of 1.0 metre in consolidated formation for proper seating of casing pipe, depth of drilling required to cover full depth of aquifer proposed to be tapped, probable yield and other information required including transportation of instruments and accessories to work site, engaging technical personal and labour required etc. NOTE: 1) Additional rate on item 1&2 is allowed for drilling in over burden and fixing Casing pipes beyond 20 M (for fixing Casing pipes only) a) Above 20 M and upto 30 M - 15%, b) Above 30 M - 30% (Measurement of overburden is restricted to theEach5552.45552.41.0FalseNoneNoneFalseNoneFalse5552.40
3252928112673None002Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete )Rmtr388.5388.550.0FalseNoneNoneFalseNoneFalse19425.00
3252929112673None003Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete )Rmtr487.2487.225.0FalseNoneNoneFalseNoneFalse12180.00
3252930112673None004Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for:M010I PVC pipes 160mm dia., 6 kg/sqcm & class 3Rmtr648.9648.912.0FalseNoneNoneFalseNoneFalse7786.80
3252931112673None005Providing and fixing MS casing collars as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendmentsEach157.5157.51.0FalseNoneNoneFalseNoneFalse157.50
3252932112673None006Providing, Single Phase Submersible Pump Sets of 100mm dia (4 inch) suitable for bore well confirming to IS 8034-2000 specifications, to work site with testing of as per instructions of engineer incharge of work and latest amendments etc. complete 2.00 HP/1.5KW 6 STGEach17335.517335.51.0FalseNoneNoneFalseNoneFalse17335.50
3252933112673None007Supplying, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc.Note: Upto 110mm dia Coil shall be used.For Grade PE80 PN10.0 :K030A HDPE Grade PE80-PN10.0,75mm diaRmtr346.5346.565.0FalseNoneNoneFalseNoneFalse22522.50
3252934112673None008Supplying and drawing 3 core flat PVC sheathed submersible pump cable manufactured with electrolytic grade copper with flexible copper with low resistance conductor confirming to13:8130-1984 and virgin grade PVC insulation and powder coating extruded PVC sheathed suitable for working voltage upto 1100 V as per IS-694:2010.Rmtr257.25257.2565.0FalseNoneNoneFalseNoneFalse16721.250
3252935112673None009Labour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all items including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges,tools and equipments etc., involved in the job as per specifications, with necessary tests as per specifications, with testing of as per instructions of engineer incharge of work.Job6825.06825.01.0FalseNoneNoneFalseNoneFalse6825.00
3252936112673None010Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOL- Direct Online Starter 2) S-D- Star Delta Starter etc. complete Upto 3 HP pumpsEach6825.06825.01.0FalseNoneNoneFalseNoneFalse6825.00
3252937112673None011Main Connection: providing main connection from pole - PVC Insulated sheathed steel wire cable as per IS 1554/1988 with latest amendments with ISI mark from KPTCL Pole to meter board unit 31/2x16 Sqm etc.,Each1522.51522.51.0FalseNoneNoneFalseNoneFalse1522.50
3252938112673None012Earthing: Supplying and fixing and wiring earth electrode for groundingcircuits IC cutouts and other equipments on the meter board in the pit. The pits should be filled up with equal proportion of salt and charcoal 150mm around the pipe to complete depth. The connection from the pipe to the conduits etc. is to established through GI wire of sizes as per clause 7.3.3 of IS 732 using 12mm bolts, nuts, washers and check nuts, the pipe shall have 16 through holes of 12mm dia.Job3937.53937.51.0FalseNoneNoneFalseNoneFalse3937.50
3252939112673None013Earth work excavation for pipeline trenches in all kinds of soils by mechanical means as per drawing and technical specifications, including setting out, construction of shoring, strutting, barricading, caution lights, bracing, using sight rails & bonding rods at every 100 mm wherever necessary as directed, removal of stumps and other deleterious matter, dressing of sides and levelling the bottom of trench to the extent required , utilising the available excavated earth locally for the work etc., and all other appurtenances complete in the following strata.All kinds of soils. Depth upto 1.50 mCum275.1275.16.75FalseNoneNoneFalseNoneFalse1856.9250
3252940112673None014Providing and installing at site of work P.V.C. pipes including cost of pipes and specials and labour, including lowering into trenches, laying true to line, level and perfect linking at joints leak proof including jointing of approved type with all labour charges and all lift charges, handling charges including encasing the pipe around to a depth not less than 15 cms with gravel or selected earth available from the excavation etc. complete M150A 4 Kg/m2: 63mm(weight of pipe -0.465 kg)m122.85122.8520.0FalseNoneNoneFalseNoneFalse2457.00
3252941112673None015Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m , and lift upto 1.5 m. Including cost of all labour complete as per specificationsCum168.0168.06.75FalseNoneNoneFalseNoneFalse1134.00
17179103620000NoneNoneBuildingsFor Smart Class400000.0
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3252942112674None001INTERACTIVE FLAT PANEL 4K UHD display & 4K UI Powered by Android 11.0 Quad-core CPU: ARM Cortex A55 4, RAM 4G, ROM 32G Super GPU: Mali G52 MP2 (2EE) IR Sensitive 20 points touch Wireless Screen Sharing, Whiteboard, Android Apps Page sharing by scanning QR-code, Annotation Rich interfaces: HDMI IN, RJ 45, RS-232, USB 3.0 etc. (GEM RATE) Detailed specificationattached Item Code 200105Nos400000.0400000.01.0FalseNoneNoneFalseNoneFalse400000.00
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17179103630000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17179103630000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17179103630000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17179103630000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17179103630000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
17179267050000NoneNoneELIGIBILITYQualifications of the tenderer required as mentioned in the Technical Bid KW-3 in General conditions 3 must be furnished.None
17179267090000NoneNoneELIGIBILITYTender of the contractor, who have not completed the work in time, not executed the agreement in time in any other cases in this Division as per Clause 3.4 of Standard Tender Document and practices as mentioned in clause 25 of the standard tender document will not be accepted.None
17179267130000NoneNoneELIGIBILITYThe undersigned reserves the right to accept any or all tenders without assigning any reason.None
17179267160000NoneNoneELIGIBILITYContractor should execute the work by procuring cement, steel any other materials/Machinery for the work on their own and necessary quality test certificate should be produced and approval of the same.None
17179267200000NoneNoneELIGIBILITYOther details can be seen in the tender documentsNone
17179267840000NoneNoneELIGIBILITYContractors should have to upload the Scan copy of all necessary Qualification Documents/ Certificates, and submitted duly attested by notary while tender Evaluvation in this DivisionNone
17179267890000NoneNoneELIGIBILITYThe Department is not responsible for any delay in accessing e-procurement portal.None
17179267930000NoneNoneELIGIBILITYTenderer shall note that the Tenders of those found Eligible as mentioned in Clause 3 Qualification of Instructions to Tenders (ITT), will only be considered for evaluation.None
17179267960000NoneNoneELIGIBILITYContractors should have to upload the necessary Qualification details as Section 3 Clause 1.1 to 1.10 in prescribed formats of KW-3.None
17179268000000NoneNoneELIGIBILITYThe contractor should counter check all the designs of the scheme before execution / procurement of material and bring to the notice of the departmental officers for rectification.None
17179268040000NoneNoneELIGIBILITYThe contractors have to verify the designs and drawings prepared by the department and supplied for construction. correct the same for any mistakes and to submit it for the approval of the department prior to commencement of execution.None
17179268090000NoneNoneELIGIBILITYThe contractor should furnish the Contractor license CertificateNone
17179268120000NoneNoneELIGIBILITYSuccessful bidder submitting bids below the amount put to tender will be regularized to submit the difference amount in the form of FDR/TDR/DD/Pledge on the name of EE PRED Raichur within 20 days from the date of receiving the letter of acceptance. Failing which EMD will be forfeited and further action will be taken as per G O No FD PCL 2008 Bangalore Dated 14/10/2008. Cluase 25 of KW-3.None
17179268160000NoneNoneELIGIBILITYThe Building constructed under this programme shall be of high standard, requiring no major repairs for 3 years, The contractor shall furnish performance guarantee for 3 years as per clause and the performance guarantee will be released only after 3 years after completion of work.None
17179268210000NoneNoneELIGIBILITYThe Tenderer shall obtain the workdone certificate in the prescribed form from the competent authority not below the rank of Executive Engineer (District Level Officer) and scan the Original Certificate and attach the scanned file to the Bid. The Original Certificate / Certificates shall be produced whenever required.None
17179268710000NoneNoneELIGIBILITYThird party inspection is mandatory for all the works in this programmeNone
17179268760000NoneNoneELIGIBILITYThe work should be completed within the stipulated period from the date of agreement & The date of agreement itself is the date of commencement of the workNone
17179268830000NoneNoneELIGIBILITYThe work should be completed in 11 months (including mansoon)None
17179268890000NoneNoneELIGIBILITYThe defect liability period is 2 years and 3 years for major construction repairs.None
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid license for executing water supply / sanitary engineering works and should have executed similar works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneOwning the following key and critical equipment for this work (xxxx, xxxx, xxxx)NoneNone
NoneNoneNoneNoneTotal value of civl engineering works executed and payments received in the last five years (year-wise)NoneNone
NoneNoneNoneNoneList of existing commitments and ongoing worksNoneNone
NoneNoneNoneNoneList of works for which tenders already submittedNoneNone
NoneNoneNoneNoneBanker Details for referenceNoneNone
NoneNoneNoneNoneConstruction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneReports on the financial standing of the tenderer, such as profit and loss statements and auditor’s reports for the last five yearsNoneNone
NoneNoneNoneNoneQualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneList of Financial Resources with CertificatesNoneNone
NoneNoneNoneNoneMinimum financial turnover (civil engineering construction works) not less than two times the annual payments from this contract (Rs. 111.64 Lakhs)Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNoneSatisfactorily completed as prime contractor at-least one such similar work of value not less than Rs. 45.91 LakhsPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneExecuted in any one year the following minimum quantities of work 1. Earthwork and Embankment : 714.15 Cum 2. PCC/RCC : 218.72 Cum 3. Steel- 12.42 Tone 4. SSM/BBM 398.89 Cum, 5. Flooring 469.57 Sqm, 6. Plastering- 634.01 SqmPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneTenderer or his identifiedPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNonePWD Registration Certificate (Class I/II/III/IV)
NoneNoneNoneNoneLiquid assets and /or availability of credit facilities of no less than Rs. 25.04 LakhsFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneLine of Credit
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
PWD Contractor Registration CertificateTrueTechnical Bid
Previous Five years Financial Turn over 2019-20 to 2023-24TrueTechnical Bid
Similar nature Work done CertificateTrueTechnical Bid
Quantity wise Work done certificateTrueTechnical Bid
Line of credit Bank letter headTrueTechnical Bid
tenderWorkLocationList
tenderAddressNone
tenderRecallDTONone