tenderSubEstimateList | createdTs | version | createdDate | modifiedDate | workCategoryName | subEstimateName | estimateTotal | itemList |
---|
1717249175000 | 0 | None | None | Buildings | FOR ELECTRICAL WORK | 942820.0 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3220841 | 111015 | None | 001 | Concealed Conduit System
Supplying heavy gauge PVC conduit pipe 19 mm dia 2 mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wirewherever necessary 19/20 mm dia 2 mm thick
(SR Item No.1.1.1 Page No. 2 of 105 of PWD ELECTRICAL Vol-6 for 202324 Common SOR) | m | 69.0 | 69.0 | 830.0 | False | None | None | False | None | False | 57270.0 | 0 | 3220842 | 111015 | None | 002 | Concealed Conduit System
Supplying heavy gauge PVC conduit pipe 25 mm dia 2mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wirewherever necessary 25 mm dia 2 mm thick (SR Item No.1.1.2 Page No.2 of 105 of PWD ELECTRICAL Vol-6 for 2023-24 Common SOR) | m | 81.0 | 81.0 | 530.0 | False | None | None | False | None | False | 42930.0 | 0 | 3220843 | 111015 | None | 003 | Concealed Conduit System
Supplying heavy gauge PVC Conduit Pipe 19/20 dia 2 mmthick with suitable size bends, metal junction boxes adhesivepaste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface andrun with 18 SWG GI fish wire run throughout the conduit wherever necessary.19/20 mm dia 2 mm thick (SR Item No.1.3.1 Page No. 2 of 105 of PWD ELECTRICAL Vol-6 for 2023-24 Common SOR) | m | 68.0 | 68.0 | 530.0 | False | None | None | False | None | False | 36040.0 | 0 | 3220844 | 111015 | None | 004 | Concealed Conduit System : Supplying heavy gauge PVC Conduit Pipe 25 dia 2 mmthick with suitable size bends, metal junction boxes adhesivepaste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface andrun with 18 SWG GI fish wire run throughout the conduit wherever necessary.25 mm dia 2 mm thick (SR Item No.1.3.2 Page No. 2 of 105 of PWD ELECTRICAL Vol-6 for 2023-24 Common SOR) | m | 79.0 | 79.0 | 370.0 | False | None | None | False | None | False | 29230.0 | 0 | 3220845 | 111015 | None | 005 | Concealed Conduit System : Supplying heavy gauge PVC Conduit Pipe 25 dia 2 mmthick with suitable size bends, metal junction boxes adhesivepaste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface andrun with 18 SWG GI fish wire run throughout the conduit wherever necessary.25 mm dia 2 mm thick (SR Item No.1.3.2 Page No. 2 of 105 of PWD ELECTRICAL Vol-6 for 2023-24 Common SOR) | Point | 285.0 | 285.0 | 195.0 | False | None | None | False | None | False | 55575.0 | 0 | 3220846 | 111015 | None | 006 | Point wiring using Copper wire with switch : Supplying and wiring adopting loop system in existing PVC Conduit
/casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch (SR Item No.2.1.2 Page No. 5 of 105 of PWD ELECTRICAL Vol-6 for 2023-24 Common SOR) | Point | 394.0 | 394.0 | 90.0 | False | None | None | False | None | False | 35460.0 | 0 | 3220847 | 111015 | None | 007 | Point wiring using Copper wire with switch : Supplying and wiring adopting loop system in existing PVC Conduit
/casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Long point above 6Mtr upto 10Mtr from tapping point to out let via switch ( SR Item No.2.1.3 Page No. 5 of 105 of PWD ELECTRICAL Vol-6 for 2023-24 Common SOR) | Point | 570.0 | 570.0 | 65.0 | False | None | None | False | None | False | 37050.0 | 0 | 3220848 | 111015 | None | 008 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. " A Group 1 to 2 Module ( SR Item No.3.5.1 Page No. 8 of 105 of PWD ELECTRICAL Vol-6 for 2023-24 Common SOR) | Each | 137.0 | 137.0 | 20.0 | False | None | None | False | None | False | 2740.0 | 0 | 3220849 | 111015 | None | 009 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting
back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. " A Group 4 Module ( SR Item No.3.5.3 Page No. 8 of 105 of PWD ELECTRICAL Vol-6 for 2023-24 Common SOR) | Each | 175.0 | 175.0 | 26.0 | False | None | None | False | None | False | 4550.0 | 0 | 3220850 | 111015 | None | 010 | Supplying and fixing superior quality modular switch mounting polycorbonate plate with necessary supporting back plate with required no's of machine screwes, bolts, nuts etc., complete on the existing metal/ PVC box. " A Group 8 Module( SR Item No.3.5.5 Page No. 8 of 105 of PWD ELECTRICAL Vol-6 for 2023-24 Common SOR) | Each | 284.0 | 284.0 | 34.0 | False | None | None | False | None | False | 9656.0 | 0 | 3220851 | 111015 | None | 011 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. " A Group 10-12 Module ( SR Item No.3.5.6 Page No. 8 of 105 of PWD ELECTRICAL Vol-6 for 2023-24 Common SOR) | Each | 344.0 | 344.0 | 30.0 | False | None | None | False | None | False | 10320.0 | 0 | 3220852 | 111015 | None | 012 | Supplying and fixing superior quality modular switch mounting polycorbonate plate with necessary supporting back plate with required no's of machine screwes, bolts, nuts etc., complete on the existing metal/ PVC box. " A Group 16 Module( SR Item No.3.5.7 Page No.8 of 105 of PWD ELECTRICAL Vol-6 for 2023-24 Common SOR) | Each | 397.0 | 397.0 | 18.0 | False | None | None | False | None | False | 7146.0 | 0 | 3220853 | 111015 | None | 013 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 1-2 Way ( SR Item No.3.4.1 Page No.8 of 105 of PWD ELECTRICAL Vol-6 for 2023-24 Common SOR) | Each | 138.0 | 138.0 | 20.0 | False | None | None | False | None | False | 2760.0 | 0 | 3220854 | 111015 | None | 014 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 4-5 Way ( SR Item No.3.4.3 Page No.8 of 105 of PWD ELECTRICAL Vol-6 for 2023-24 Common SOR) | Each | 177.0 | 177.0 | 26.0 | False | None | None | False | None | False | 4602.0 | 0 | 3220855 | 111015 | None | 015 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 8 Way ( SR Item No.3.4.5 Page No.8 of 105 of PWD ELECTRICAL Vol-6 for 2023-24 Common SOR) | Each | 261.0 | 261.0 | 34.0 | False | None | None | False | None | False | 8874.0 | 0 | 3220856 | 111015 | None | 016 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates.
The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 10-12 Way ( SR Item No.3.4.6 Page No.8 of 105 of PWD ELECTRICAL Vol-6 for 2023-24 Common SOR) | Each | 319.0 | 319.0 | 30.0 | False | None | None | False | None | False | 9570.0 | 0 | 3220857 | 111015 | None | 017 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 16 Way ( SR Item No.3.4.7 Page No.8 of 105 of PWD ELECTRICAL Vol-6 for 2023-24 Common SOR) | Each | 363.0 | 363.0 | 18.0 | False | None | None | False | None | False | 6534.0 | 0 | 3220858 | 111015 | None | 018 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.Group A Materials.1.5 sqmm ( SR Item No.2.3.2 Page No.5 of 105 of PWD ELECTRICAL Vol-6 for 2023-24Common SOR) | Mtr | 26.0 | 26.0 | 2200.0 | False | None | None | False | None | False | 57200.0 | 0 | 3220859 | 111015 | None | 019 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.Group A Materials.2.5 sqmm (SR Item No.2.3.3 Page No.5 of 105 of PWD ELECTRICAL Vol-6 for 2023-24 Common SOR) | Mtr | 42.0 | 42.0 | 1350.0 | False | None | None | False | None | False | 56700.0 | 0 | 3220860 | 111015 | None | 020 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.Group A Materials.4 sqmm (SR Item No.2.3.4 Page No.5 of 105 of PWD ELECTRICAL Vol-6 for 2023-24 Common SOR) | Mtr | 63.0 | 63.0 | 600.0 | False | None | None | False | None | False | 37800.0 | 0 | 3220861 | 111015 | None | 021 | Supplying & Fixing of 70-150 Watts lamp holder 2 Pin ( SR Item No.12.46 Page No.52 of 105 of PWD ELECTRICAL Vol-6 for 2023-24 Common SOR) | No | 63.0 | 63.0 | 60.0 | False | None | None | False | None | False | 3780.0 | 0 | 3220862 | 111015 | None | 022 | Supplying of .feet - PVC Batten with integrated LED tube .W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. 1x 4' - 20 /22 w ( SR Item No.11.3.2 Page No.43 of 105 of PWD ELECTRICAL Vol-6 for 2023-24 Common SOR) | Each | 690.0 | 690.0 | 68.0 | False | None | None | False | None | False | 46920.0 | 0 | 3220863 | 111015 | None | 023 | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles, Single phase AC supply conforming ot ISS-374-1979 and with double ball bearing system. 48" Sweep (1200mm) Regular model ( SR Item No.6.3.1 Page No.30 of 105 of PWD ELECTRICAL Vol-6 for 2023-24 Common SOR) | Each | 2984.0 | 2984.0 | 52.0 | False | None | None | False | None | False | 155168.0 | 0 | 3220864 | 111015 | None | 024 | Fixing all types and all capacities of fluorescent/false ceiling/spot light/CFL/LED fittings indoor on the wall/ceiling/rafters/girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clamps On wall/Ceiling/Rafter/Girders (SR Item No.13.7.1 Page No.56 of 105 of PWD ELECTRICAL Vol-6 for 2023-24 Common SOR) | Each | 122.0 | 122.0 | 68.0 | False | None | None | False | None | False | 8296.0 | 0 | 3220865 | 111015 | None | 025 | Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S' hook with fan regulator to the existing board together with supplying and fixing 5 amps. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring.(SR Item No.13.10 Page No.57 of 105 of PWD ELECTRICAL Vol-6 for 2023-24 Common SOR) | Each | 171.0 | 171.0 | 52.0 | False | None | None | False | None | False | 8892.0 | 0 | 3220866 | 111015 | None | 026 | Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/ panel using necessary nuts, bolts and washers etc., complete 32 Amps (SR Item No.5.7.2 Page No.14 of 105 of PWD ELECTRICAL Vol-6 for 2023-24 Common SOR) | Each | 241.0 | 241.0 | 3.0 | False | None | None | False | None | False | 723.0 | 0 | 3220867 | 111015 | None | 027 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and "C" Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity on 10 K and complete wiring as required confirming to IEC 60898 6-32 Amps SP (SR Item No. 5.18.1 Page No.17 of 105 of PWD ELECTRICAL Vol-6 for 2023-24 Common SOR) | Each | 415.0 | 415.0 | 30.0 | False | None | None | False | None | False | 12450.0 | 0 | 3220868 | 111015 | None | 028 | Supplying and fixing regular MCB distribution boards on wall/wood board/flush mounting using required clamps, bolts, nuts etc. with provision for fixing suitable type capacity MCB's single phase/3 Phase/single door with powder coated painting. Made out of 14 SWG MS enclosure I- Single Door 12 Way SP & N (SR Item No. 5.19.4
Page No. 18 of 105 of PWD ELECTRICAL Vol-6 for 2023-24 Common SOR) | Each | 1863.0 | 1863.0 | 6.0 | False | None | None | False | None | False | 11178.0 | 0 | 3220869 | 111015 | None | 029 | Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V up to 300mA sensitivity on existing wood/ panel board.25 amps 2 pole (SR Item No. 5.20.1 Page No.18 of 105 of PWD ELECTRICAL Vol-6 for 2023-24 Common SOR) | Each | 4277.0 | 4277.0 | 1.0 | False | None | None | False | None | False | 4277.0 | 0 | 3220870 | 111015 | None | 030 | Supplying, fixing and wiring Electronic Trivector Meter (ETV) 5 to 20Amps single phase Class-1 Accuracy with Temper Proof Energy Meter.(SR Item No. 5.30 Page No. 18 of 105 of PWD ELECTRICAL Vol-6 for 2023-24 Common SOR) | Each | 1380.0 | 1380.0 | 1.0 | False | None | None | False | None | False | 1380.0 | 0 | 3220871 | 111015 | None | 031 | Supplying & fixing retrofit type-PL- LED Lamp 18-20 W LED linear source with CCT 6500 degree K, CRI 70%. efficacy 80 lumen per W, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80.The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp Wage. short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to275 V. bTested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.(SR Item No. 11.2.2
Page No. 43 of 105 of PWD ELECTRICAL Vol-6 for 2023-24 Common SOR) | Each | 702.0 | 702.0 | 48.0 | False | None | None | False | None | False | 33696.0 | 0 | 3220872 | 111015 | None | 032 | Supplying and Fixing 32mm dia class A GI pipe bracket up to 2.7 meters long terminated with a reducing collar of 40x25mm to which extra pipe of 175mm length is fixed for fixing LED street light fitting of all capacities on rail/RCC/wall/tubular pole, using suitable clamps, bolts, nuts and wiring using suitable capacity wires.(SR No.13.2.2, Page No.56 of 105 of PWD ELECTRICAL Vol-6 for 2023-24Common SOR) | Each | 1295.0 | 1295.0 | 6.0 | False | None | None | False | None | False | 7770.0 | 0 | 3220873 | 111015 | None | 033 | Supplying and fixing of modular switch & connected accessorieson existing modular switch plate as per IS 3854 and IS 1293 6/16A Universal Socket (SR Item No. 3.6.11 Page No. 9 of 105 of PWD ELECTRICAL Vol-6 for 2023-24 Common SOR) | Each | 236.0 | 236.0 | 45.0 | False | None | None | False | None | False | 10620.0 | 0 | 3220874 | 111015 | None | 034 | Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board.Electronic stepped
regulator. (SR Item No. 3.14.16 Page No.10 of 105 of PWD ELECTRICAL Vol-6 for 2023-24 Common SOR) | Each | 281.0 | 281.0 | 52.0 | False | None | None | False | None | False | 14612.0 | 0 | 3220875 | 111015 | None | 037 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854
and IS 1293.TV/Telephone Socket,(SR Item No.3.6.11,Page No 9 of 105 of PWD ELECTRICAL Vol-6 for 2023-24 Common SOR) | Each | 156.0 | 156.0 | 6.0 | False | None | None | False | None | False | 936.0 | 0 | 3220876 | 111015 | None | 038 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.6A One Way Switch,(SR Item No.3.6.1,Page No 10 of 105 of PWD ELECTRICAL Vol-6 for 2023-24 Common SOR)
SOR) | Each | 102.0 | 102.0 | 360.0 | False | None | None | False | None | False | 36720.0 | 0 | 3220877 | 111015 | None | 039 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.6A Two Way Switch,(SR Item No.3.6.2,Page No 10 of 105 of PWD ELECTRICAL Vol-6 for 2023-24 Common SOR) | Each | 166.0 | 166.0 | 8.0 | False | None | None | False | None | False | 1328.0 | 0 | 3220878 | 111015 | None | 040 | Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with 40W System Power consumption. LED Efficiency130lm/w, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Streetlight 40watts
(SR Item No.11.8.2, Page 46 of 105 of PWD ELECTRICAL Vol-6 for 2023-24 Common SOR) | Each | 4024.0 | 4024.0 | 6.0 | False | None | None | False | None | False | 24144.0 | 0 | 3220879 | 111015 | None | 041 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.6A Three Way socket Switch,(SR Item No.3.6.3,Page No 10 of 105 of PWD ELECTRICAL Vol-6 for 2023-24 Common SOR) | Each | 171.0 | 171.0 | 85.0 | False | None | None | False | None | False | 14535.0 | 0 | 3220880 | 111015 | None | 042 | Fixing all types and all capacities of fluorescent/false ceiling/spot light/CFL/LED fittings indoor on the wall/ceiling/rafters/girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clamps On wall/Ceiling/Rafter/Girders (SR Item No.13.7.1 Page No.56 of 105 of PWD ELECTRICAL Vol-6 for 2023-24 Common SOR) | Each | 122.0 | 122.0 | 125.0 | False | None | None | False | None | False | 15250.0 | 0 | 3220881 | 111015 | None | 043 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.6A/16 A one Way Switch ,(SR Item No.3.6.10,Page No 9 of 105 of PWD ELECTRICAL Vol-6 for 2023-24 Common SOR) | Each | 236.0 | 236.0 | 45.0 | False | None | None | False | None | False | 10620.0 | 0 | 3220882 | 111015 | None | 044 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.6A 6A Bell Push ,(SR Item No.3.6.8,Page No 9 of 105 of PWD ELECTRICAL Vol-6 for 2023-24 Common SOR) | Each | 177.0 | 177.0 | 3.0 | False | None | None | False | None | False | 531.0 | 0 | 3220883 | 111015 | None | 045 | Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clA, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure.Double Door 12 Way TP &N ,(SR Item No.5.19.9,Page No 18 of 105 of PWD ELECTRICAL Vol-6 for 2023-24 Common SOR) | Each | 2329.0 | 2329.0 | 3.0 | False | None | None | False | None | False | 6987.0 | 0 |
| 1717249175000 | 0 | None | None | Buildings | For Furniture | 593000.0 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3220884 | 111016 | None | 001 | Visitor Chair - Visitor chairs with firm leatherette cushion is an ideal option for waiting areas or reception rooms. Design with steel chrome finish. | No | 7800.0 | 7800.0 | 5.0 | False | None | None | False | None | False | 39000.0 | 0 | 3220885 | 111016 | None | 002 | Conference table : Have a dedicated meeting space for staff to discuss projects and brainstrom around this modern conference table. The 94 inch conference room table is size perfectly for group with seating for eight. The boardroom table is shaped appropriatly to be seen by each menber as they provid thier verbal input. Panel legs have screw-in adjustable feet to level the unit on uneven floor surfaces while the middle panel adds stablitiy. laminate surface are easy to wipe clean wheather used frequently or on occasion. if you have a large enougn space in your office. Bring your team togeather on a regular basis when you a true conference space where everyone is confortable bringing thier ideas to the table. | No | 26500.0 | 26500.0 | 2.0 | False | None | None | False | None | False | 53000.0 | 0 | 3220886 | 111016 | None | 003 | Office 1.2 meter table made of HDF, walnut finish with aluminum beadig. The table gives a classy executive look. This table set has one drawer & one shutter door storage. | No | 14750.0 | 14750.0 | 4.0 | False | None | None | False | None | False | 59000.0 | 0 | 3220887 | 111016 | None | 004 | Three seater students dual Desk (Beanch & desk for class room) | No | 8500.0 | 8500.0 | 52.0 | False | None | None | False | None | False | 442000.0 | 0 |
| 1717249175000 | 0 | None | None | Buildings | Construction of 5 Nos of Class rooms, 4 Nos of Laboratory, 4 Nos Toilet rooms, 2 Nos Womens Rest rooms, and 1 No of Library to Government First Grade College at Raichur Cicty. Under KKRDB Mega MACRO for the year 2022-23 | 12620197.53 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3220888 | 111017 | None | 001 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (The cost of steel reinforcement &
formwork to be paid separately) with all lead and lifts etc., complete and as directed by the Engineer in charge of work Lintel Beam | Cum | 11496.24 | 11496.24 | 21.11 | False | None | None | False | None | False | 242685.6264 | 0 | 3220889 | 111017 | None | 002 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (The cost of steel reinforcement &
formwork to be paid separately) with all lead and lifts etc., complete and as directed by the Engineer in charge of work For Slab | Cum | 10777.7 | 10777.7 | 42.527 | False | None | None | False | None | False | 458343.2479 | 0 | 3220890 | 111017 | None | 003 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (The cost of steel reinforcement &
formwork to be paid separately) with all lead and lifts etc., complete and as directed by the Engineer in charge of work | Cum | 10418.47 | 10418.47 | 5.876 | False | None | None | False | None | False | 61218.92972 | 0 | 3220891 | 111017 | None | 004 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (The cost of steel reinforcement &
formwork to be paid separately) with all lead and lifts etc., complete and as directed by the Engineer in charge of work Lintel Beam | Cum | 11399.42 | 11399.42 | 7.948 | False | None | None | False | None | False | 90602.59016 | 0 | 3220892 | 111017 | None | 005 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (The cost of steel reinforcement &
formwork to be paid separately) with all lead and lifts etc., complete and as directed by the Engineer in charge of work Roof Beam | Cum | 10728.87 | 10728.87 | 21.596 | False | None | None | False | None | False | 231700.67652 | 0 | 3220893 | 111017 | None | 006 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (The cost of steel reinforcement &
formwork to be paid separately) with all lead and lifts etc., complete and as directed by the Engineer in charge of work | Cum | 10058.31 | 10058.31 | 3.885 | False | None | None | False | None | False | 39076.53435 | 0 | 3220894 | 111017 | None | 007 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (The cost of steel reinforcement &
formwork to be paid separately) with all lead and lifts etc., complete and as directed by the Engineer in charge of work | Cum | 9723.04 | 9723.04 | 5.651 | False | None | None | False | None | False | 54944.89904 | 0 | 3220895 | 111017 | None | 008 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(The cost of steel reinforcement &
formwork to be paid separately) with all lead and lifts etc., complete and as directed by the Engineer-in-charge of work. Second Floor | Cum | 11512.29 | 11512.29 | 7.948 | False | None | None | False | None | False | 91499.68092 | 0 | 3220896 | 111017 | None | 009 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(The cost of steel reinforcement &
formwork to be paid separately) with all lead and lifts etc., complete and as directed by the Engineer-in-charge of work. Lintel beam | Cum | 10835.09 | 10835.09 | 21.596 | False | None | None | False | None | False | 233994.60364 | 0 | 3220897 | 111017 | None | 010 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(The cost of steel reinforcement &
formwork to be paid separately) with all lead and lifts etc., complete and as directed by the Engineer-in-charge of work. Slab | Cum | 10157.9 | 10157.9 | 3.885 | False | None | None | False | None | False | 39463.4415 | 0 | 3220898 | 111017 | None | 011 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(The cost of steel reinforcement &
formwork to be paid separately) with all lead and lifts etc., complete and as directed by the Engineer-in-charge of work. Chajja at Above | Cum | 9819.3 | 9819.3 | 5.088 | False | None | None | False | None | False | 49960.5984 | 0 | 3220899 | 111017 | None | 012 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(The cost of steel reinforcement & formwork to be paid separately) with all lead and lifts etc., complete and as directed by the Engineer-in-charge of work. Terrace Floor | Cum | 11625.2 | 11625.2 | 0.673 | False | None | None | False | None | False | 7823.7596 | 0 | 3220900 | 111017 | None | 013 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(The cost of steel reinforcement & formwork to be paid separately) with all lead and lifts etc., complete and as directed by the Engineer-in-charge of work. Roof Beam | Cum | 10941.32 | 10941.32 | 1.0001 | False | None | None | False | None | False | 10942.414132 | 0 | 3220901 | 111017 | None | 014 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(The cost of steel reinforcement & formwork to be paid separately) with all lead and lifts etc., complete and as directed by the Engineer-in-charge of work.Slab | Cum | 10257.49 | 10257.49 | 0.48 | False | None | None | False | None | False | 4923.5952 | 0 | 3220902 | 111017 | None | 015 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(The cost of steel reinforcement & formwork to be paid separately) with all lead and lifts etc., complete and as directed by the Engineer-in-charge of work. | Cum | 9915.57 | 9915.57 | 0.113 | False | None | None | False | None | False | 1120.45941 | 0 | 3220903 | 111017 | None | 016 | roviding Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) with all lead and lifts etc., complete and as directed by the Engineer-in-charge of work. | Kgs | 93.93 | 93.93 | 11039.76 | False | None | None | False | None | False | 1036964.6568 | 0 | 3220904 | 111017 | None | 017 | roviding Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) with all lead and lifts etc., complete and as directed by the Engineer-in-charge of work. | Kgs | 93.93 | 93.93 | 11039.76 | False | None | None | False | None | False | 1036964.6568 | 0 | 3220905 | 111017 | None | 018 | roviding Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) with all lead and lifts etc., complete and as directed by the Engineer-in-charge of work. | Kgs | 93.93 | 93.93 | 11039.76 | False | None | None | False | None | False | 1036964.6568 | 0 | 3220906 | 111017 | None | 019 | roviding Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) with all lead and lifts etc., complete and as directed by the Engineer-in-charge of work. | Kgs | 93.93 | 93.93 | 118.053 | False | None | None | False | None | False | 11088.71829 | 0 | 3220907 | 111017 | None | 020 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. | Cum | 8621.6 | 8621.6 | 46.219 | False | None | None | False | None | False | 398481.7304 | 0 | 3220908 | 111017 | None | 021 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. First Floor | Cum | 8621.6 | 8621.6 | 55.735 | False | None | None | False | None | False | 480524.876 | 0 | 3220909 | 111017 | None | 022 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. Second Floor | Cum | 8621.6 | 8621.6 | 55.735 | False | None | None | False | None | False | 480524.876 | 0 | 3220910 | 111017 | None | 023 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.Terrace Floor | Cum | 8621.6 | 8621.6 | 23.286 | False | None | None | False | None | False | 200762.5776 | 0 | 3220911 | 111017 | None | 024 | Providing 12 mm cement plaster with cement mortar 1:4 (1 cement:4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications with all lead and lifts etc., complete and as directed by the Engineer-in-charge of work Ground Floor | Sqm | 267.75 | 267.75 | 499.5 | False | None | None | False | None | False | 133741.125 | 0 | 3220912 | 111017 | None | 025 | Providing 12 mm cement plaster with cement mortar 1:4 (1 cement:4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications with all lead and lifts etc., complete and as directed by the Engineer-in-charge of work First Floor | Sqm | 267.75 | 267.75 | 379.179 | False | None | None | False | None | False | 101525.17725 | 0 | 3220913 | 111017 | None | 026 | Providing 12 mm cement plaster with cement mortar 1:4 (1 cement:4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications with all lead and lifts etc., complete and as directed by the Engineer-in-charge of work Second Floor | Sqm | 267.75 | 267.75 | 542.979 | False | None | None | False | None | False | 145382.62725 | 0 | 3220914 | 111017 | None | 027 | Providing 12 mm cement plaster with cement mortar 1:4 (1 cement:4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications with all lead and lifts etc., complete and as directed by the Engineer-in-charge of work Terrace Floor | Sqm | 267.75 | 267.75 | 37.74 | False | None | None | False | None | False | 10104.885 | 0 | 3220915 | 111017 | None | 028 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing omplete as per specifications with all lead and lifts etc., complete and as directed by the Engineer-in-charge of work Ground Floor | Sqm | 366.45 | 366.45 | 167.13 | False | None | None | False | None | False | 61244.7885 | 0 | 3220916 | 111017 | None | 029 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing omplete as per specifications with all lead and lifts etc., complete and as directed by the Engineer-in-charge of work First Floor | Sqm | 366.45 | 366.45 | 215.188 | False | None | None | False | None | False | 78855.6426 | 0 | 3220917 | 111017 | None | 030 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing omplete as per specifications with all lead and lifts etc., complete and as directed by the Engineer-in-charge of work Second Floor | Sqm | 366.45 | 366.45 | 215.188 | False | None | None | False | None | False | 78855.6426 | 0 | 3220918 | 111017 | None | 031 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing omplete as per specifications with all lead and lifts etc., complete and as directed by the Engineer-in-charge of work Terrace Floor | Sqm | 366.45 | 366.45 | 106.0 | False | None | None | False | None | False | 38843.7 | 0 | 3220919 | 111017 | None | 032 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications with all lead and lifts etc., complete and as directed by the Engineer-in-charge of work. Ground Floor | Sqm | 105.0 | 105.0 | 499.5 | False | None | None | False | None | False | 52447.5 | 0 | 3220920 | 111017 | None | 033 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications with all lead and lifts etc., complete and as directed by the Engineer-in-charge of work. First Floor | Sqm | 105.0 | 105.0 | 379.179 | False | None | None | False | None | False | 39813.795 | 0 | 3220921 | 111017 | None | 034 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications with all lead and lifts etc., complete and as directed by the Engineer-in-charge of work. Second Floor | Sqm | 105.0 | 105.0 | 379.179 | False | None | None | False | None | False | 39813.795 | 0 | 3220922 | 111017 | None | 035 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications with all lead and lifts etc., complete and as directed by the Engineer-in-charge of work. Terrace Floor | Sqm | 105.0 | 105.0 | 37.74 | False | None | None | False | None | False | 3962.7 | 0 | 3220923 | 111017 | None | 036 | Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge. For Ground Floor | Sqm | 104.0 | 104.0 | 499.5 | False | None | None | False | None | False | 51948.0 | 0 | 3220924 | 111017 | None | 037 | Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge. For First Floor | Sqm | 104.0 | 104.0 | 379.179 | False | None | None | False | None | False | 39434.616 | 0 | 3220925 | 111017 | None | 038 | Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge. For Second Floor Floor | Sqm | 104.0 | 104.0 | 379.179 | False | None | None | False | None | False | 39434.616 | 0 | 3220926 | 111017 | None | 039 | Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge. For Terrace Floor | Sqm | 104.0 | 104.0 | 37.74 | False | None | None | False | None | False | 3924.96 | 0 | 3220927 | 111017 | None | 040 | Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. For Ground Floor. | Sqm | 182.7 | 182.7 | 129.15 | False | None | None | False | None | False | 23595.705 | 0 | 3220928 | 111017 | None | 041 | Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. For First Floor. | Sqm | 182.7 | 182.7 | 215.188 | False | None | None | False | None | False | 39314.8476 | 0 | 3220929 | 111017 | None | 042 | Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. For Second Floor. | Sqm | 182.7 | 182.7 | 215.188 | False | None | None | False | None | False | 39314.8476 | 0 | 3220930 | 111017 | None | 043 | Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. For Terrace Floor. | Sqm | 182.7 | 182.7 | 106.0 | False | None | None | False | None | False | 19366.2 | 0 | 3220931 | 111017 | None | 044 | Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 20 mm to 25 mm wide to required depth for Ground floor | m | 69.3 | 69.3 | 60.72 | False | None | None | False | None | False | 4207.896 | 0 | 3220932 | 111017 | None | 045 | Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 20 mm to 25 mm wide to required depth for First floor | m | 69.3 | 69.3 | 60.72 | False | None | None | False | None | False | 4207.896 | 0 | 3220933 | 111017 | None | 046 | Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 20 mm to 25 mm wide to required depth for Second floor | m | 69.3 | 69.3 | 60.72 | False | None | None | False | None | False | 4207.896 | 0 | 3220934 | 111017 | None | 047 | Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 20 mm to 25 mm wide to required depth for Terrace floor | m | 103.95 | 103.95 | 8.92 | False | None | None | False | None | False | 927.234 | 0 | 3220935 | 111017 | None | 048 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer- in-Charge. For Ground Floor | Kgs | 593.0 | 593.0 | 12.42 | False | None | None | False | None | False | 7365.06 | 0 | 3220936 | 111017 | None | 049 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer- in-Charge. For First Floor | Kgs | 593.0 | 593.0 | 12.42 | False | None | None | False | None | False | 7365.06 | 0 | 3220937 | 111017 | None | 050 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer- in-Charge. For Second Floor | Kgs | 593.0 | 593.0 | 12.42 | False | None | None | False | None | False | 7365.06 | 0 | 3220938 | 111017 | None | 051 | Providing Honne wood wrought and putup for purlins, common rafters and similar work including cost of materials, labour, usage charges complete as per specifications with all lead and lifts etc., complete and as directed by the Engineer-in-charge of work. For Ground floor | Cum | 143083.5 | 143083.5 | 0.3023 | False | None | None | False | None | False | 43254.14205 | 0 | 3220939 | 111017 | None | 052 | Providing Honne wood wrought and putup for purlins, common rafters and similar work including cost of materials, labour, usage charges complete as per specifications with all lead and lifts etc., complete and as directed by the Engineer-in-charge of work. For First floor | Cum | 143083.5 | 143083.5 | 0.12 | False | None | None | False | None | False | 17170.02 | 0 | 3220940 | 111017 | None | 053 | Providing Honne wood wrought and putup for purlins, common rafters and similar work including cost of materials, labour, usage charges complete as per specifications with all lead and lifts etc., complete and as directed by the Engineer-in-charge of work. For Second floor | Cum | 143083.5 | 143083.5 | 0.12 | False | None | None | False | None | False | 17170.02 | 0 | 3220941 | 111017 | None | 054 | Providing Honne wood wrought and putup for purlins, common rafters and similar work including cost of materials, labour, usage charges complete as per specifications with all lead and lifts etc., complete and as directed by the Engineer-in-charge of work. For Terrace floor | Cum | 93460.5 | 93460.5 | 0.03 | False | None | None | False | None | False | 2803.815 | 0 | 3220942 | 111017 | None | 055 | Providing and fixing in position fully panelled Matti/Nandi wood shutters for doors with, stiles and rails of 35mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. (excluding cost of fixtures ) with all lead and lifts etc., complete and as directed by the Engineer-in-charge of work. For Grouond Floor. | Sqm | 6904.8 | 6904.8 | 54.9 | False | None | None | False | None | False | 379073.52 | 0 | 3220943 | 111017 | None | 056 | Providing and fixing in position fully panelled Matti/Nandi wood shutters for doors with, stiles and rails of 35mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. (excluding cost of fixtures ) with all lead and lifts etc., complete and as directed by the Engineer-in-charge of work. For First Floor. | Sqm | 6904.8 | 6904.8 | 55.08 | False | None | None | False | None | False | 380316.384 | 0 | 3220944 | 111017 | None | 057 | Providing and fixing in position fully panelled Matti/Nandi wood shutters for doors with, stiles and rails of 35mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. (excluding cost of fixtures ) with all lead and lifts etc., complete and as directed by the Engineer-in-charge of work. For Second Floor. | Sqm | 6904.8 | 6904.8 | 73.08 | False | None | None | False | None | False | 504602.784 | 0 | 3220945 | 111017 | None | 058 | Providing and fixing in position fully panelled Matti/Nandi wood shutters for doors with, stiles and rails of 35mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. (excluding cost of fixtures ) with all lead and lifts etc., complete and as directed by the Engineer-in-charge of work. For Terrace Floor. | Sqm | 6904.8 | 6904.8 | 2.1 | False | None | None | False | None | False | 14500.08 | 0 | 3220946 | 111017 | None | 059 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications with all lead and lifts etc., complete and as directed by the Engineer-in-charge of work. For Ground Floor | Nos | 1066.8 | 1066.8 | 10.0 | False | None | None | False | None | False | 10668.0 | 0 | 3220947 | 111017 | None | 060 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications with all lead and lifts etc., complete and as directed by the Engineer-in-charge of work. For First Floor | Nos | 1066.8 | 1066.8 | 10.08 | False | None | None | False | None | False | 10753.344 | 0 | 3220948 | 111017 | None | 061 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications with all lead and lifts etc., complete and as directed by the Engineer-in-charge of work. For Second Floor | Nos | 1066.8 | 1066.8 | 4.0 | False | None | None | False | None | False | 4267.2 | 0 | 3220949 | 111017 | None | 062 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications with all lead and lifts etc., complete and as directed by the Engineer-in-charge of work. For Terrace Floor | Nos | 1066.8 | 1066.8 | 1.0 | False | None | None | False | None | False | 1066.8 | 0 | 3220950 | 111017 | None | 063 | Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge | Sqm | 333.9 | 333.9 | 11.34 | False | None | None | False | None | False | 3786.426 | 0 | 3220951 | 111017 | None | 064 | Providing and fixing M.S. grills of required pattern in frames of windows
etc. with M.S. flats, square or round bars etc. including priming coat with
approved steel primer all complete. Fixed to openings /wooden frames
with rawl plugs screws etc. with 28 kgs/Sqm with all lead and lifts etc., complete and as directed by the Engineer-in-charge of work For Ground Floor | Kgs | 192.15 | 192.15 | 39.24 | False | None | None | False | None | False | 7539.966 | 0 | 3220952 | 111017 | None | 065 | Providing and fixing M.S. grills of required pattern in frames of windows
etc. with M.S. flats, square or round bars etc. including priming coat with
approved steel primer all complete. Fixed to openings /wooden frames
with rawl plugs screws etc. with 28 kgs/Sqm with all lead and lifts etc., complete and as directed by the Engineer-in-charge of work For First Floor | Kgs | 192.15 | 192.15 | 1260.0 | False | None | None | False | None | False | 242109.0 | 0 | 3220953 | 111017 | None | 066 | Providing and fixing M.S. grills of required pattern in frames of windows
etc. with M.S. flats, square or round bars etc. including priming coat with
approved steel primer all complete. Fixed to openings /wooden frames
with rawl plugs screws etc. with 28 kgs/Sqm with all lead and lifts etc., complete and as directed by the Engineer-in-charge of work For Second Floor | Kgs | 192.15 | 192.15 | 1260.0 | False | None | None | False | None | False | 242109.0 | 0 | 3220954 | 111017 | None | 067 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) For Ground Floor | Sqm | 7070.7 | 7070.7 | 38.7 | False | None | None | False | None | False | 273636.09 | 0 | 3220955 | 111017 | None | 068 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) For First Floor | Sqm | 7070.7 | 7070.7 | 45.0 | False | None | None | False | None | False | 318181.5 | 0 | 3220956 | 111017 | None | 069 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) For Second Floor | Sqm | 7070.7 | 7070.7 | 45.0 | False | None | None | False | None | False | 318181.5 | 0 | 3220957 | 111017 | None | 070 | Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm sand cast Iron P or S trap, 10 litre low level whiteP.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: (White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests) with all lead and lifts etc., complete and as directed by the Engineer-in-charge of work | Each | 5128.2 | 5128.2 | 6.0 | False | None | None | False | None | False | 30769.2 | 0 | 3220958 | 111017 | None | 071 | Providing and fixing wash basin with C.I. brackets, 15 mm PTMT pillar
cock, 32 mm PTMT waste coupling of standard pattern, including painting
of fittings and brackets, cutting and making good the walls wherever
required. White Vitreous China Flat back wash basin size 550x400 mm
with single 15 mm PTMT piller cock with all lead and lifts etc., complete and as directed by the Engineer-in-charge of work | Each | 2410.8 | 2410.8 | 4.0 | False | None | None | False | None | False | 9643.2 | 0 | 3220959 | 111017 | None | 072 | Providing Flush/ Ruled pointing on stone slab ceiling with cement mortar 1:2 (1 cement : 2 fine sand) after raking joints to depth nicely lining, including cost of materials, labour, curing as per specifications and as per directions of Engineer-in- charge. | Sqm | 149.1 | 149.1 | 36.0 | False | None | None | False | None | False | 5367.6 | 0 | 3220960 | 111017 | None | 073 | Providing flooring with 25mm thick polished Cuddapah slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab, including cost of materials, labour, curing, polishing complete as per specifications with all lead and lifts etc. complete and as directed by the Engineer in charge of work For Ground Floor | Sqm | 1732.5 | 1732.5 | 347.214 | False | None | None | False | None | False | 601548.255 | 0 | 3220961 | 111017 | None | 074 | Providing flooring with 25mm thick polished Cuddapah slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab, including cost of materials, labour, curing, polishing complete as per specifications with all lead and lifts etc. complete and as directed by the Engineer in charge of work For First Floor | Sqm | 1732.5 | 1732.5 | 266.419 | False | None | None | False | None | False | 461570.9175 | 0 | 3220962 | 111017 | None | 075 | Providing flooring with 25mm thick polished Cuddapah slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab, including cost of materials, labour, curing, polishing complete as per specifications with all lead and lifts etc. complete and as directed by the Engineer in charge of work For Second Floor | Sqm | 1732.5 | 1732.5 | 330.349 | False | None | None | False | None | False | 572329.6425 | 0 | 3220963 | 111017 | None | 076 | Flooring with 25mm thick polished tandur blue stone slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab, including cost of materials, labour, curing, polishing complete as per specifications with all lead and lifts etc., complete and as directed by the Engineer-in-charge of work. | Sqm | 1622.3 | 1622.3 | 54.225 | False | None | None | False | None | False | 87969.2175 | 0 | 3220964 | 111017 | None | 077 | Providing lath plaster with cement mortar 1:3, 5cms thick with 6mm dia mild steel bars at 20 cms. C to c both horizontally and vertically fixing chicken mesh for drop chajja, facia, backing to cup boards including cost of all materials, labour, providing and removing form work HOM of machineries, curing, complete as per specifications with all lead and lifts etc., complete and as directed by the Engineer-in-charge of work | Sqm | 1299.9 | 1299.9 | 66.6 | False | None | None | False | None | False | 86573.34 | 0 | 3220965 | 111017 | None | 078 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conformating to IS :13592 Type A, including jointing wth seal ring conforming IS : 5382, Leaving 10mm gap for thermal expansion, (i) single soketed pipes 100 mm diameter with all lead and lifts etc., complete and as directed by the Engineer-in-charge of work | m | 305.55 | 305.55 | 96.0 | False | None | None | False | None | False | 29332.8 | 0 | 3220966 | 111017 | None | 079 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall (50 mm nominal dia Pipes) with all lead and lifts etc., complete and as directed by the Engineer-in-charge of work | m | 820.05 | 820.05 | 240.0 | False | None | None | False | None | False | 196812.0 | 0 | 3220967 | 111017 | None | 080 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand),jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 1000x1000 mm with all lead and lifts etc., complete and as directed by the Engineer-in-charge of work. | Sqm | 1957.2 | 1957.2 | 11.7 | False | None | None | False | None | False | 22899.24 | 0 | 3220968 | 111017 | None | 081 | Providing skirting, dadooing, rises of steps with white glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications with all lead and lifts etc., complete and as directed by the Engineer-in-charge of work. | Sqm | 1461.6 | 1461.6 | 70.56 | False | None | None | False | None | False | 103130.496 | 0 | 3220969 | 111017 | None | 082 | Constructing brick masonry chamber of internal dimension 600x450mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost
of CI frame and cover with all lead and lifts etc., complete and as directed by the Engineer-in-charge of work. | Each | 4592.7 | 4592.7 | 12.0 | False | None | None | False | None | False | 55112.4 | 0 | 3220970 | 111017 | None | 083 | Providing and constructing “WIRE CUT BRICK MACHINEHOLE CHAMBERS” using Portland/Pozzolana cement, conical in shape at top, with CC 1:3:6 foundation using 40mm and down size graded metal of approved quality and with an offset of 0.15M alround the chamber. Construct Brick masonry in CM 1:4, 340 mm thick, with wirecut bricks of approved quality, plaster inside and out side with CM 1:3, 12mm thick, except for the conical surface outside where the plaster thickness shall be 20mm. Slope inside to be 1:6 in the concrete towards central drain and finished smooth. Fixing of pipes in CC 1:2:4 with graded metal of 20mm and down size. Supplying and fixing SFRC Machinehole frame and cover (Heavy Duty) conforming to IS:12592 with latest amendment, in CC 1:2:4. Supplying and fixing footsteps made of 12mm dia. steel bars (Fe-500) with 3mm thick plastic encapsulation (IS-10910). The footsteps shall be fixed 30cms apart and on CC block embeded to masonry wall. The whole works include watering, curing, barricading, danger lighting, pouring tar over MH frame and cover, cost of tar, shoring, strutting, de watering, engraving Machinehole number with flow direction on the inner conical surface etc. as per the drawing etc. as per technical specificationsand for the following diameters and depth etc. for 1.2mm diaCirc. B M.H: Constructing Brick Masonry Circular Machinehole 1.2 m internal dia. , 1.2 M
depth & SFRC cover & frame with all lead and lifts etc., complete and as directed by the Engineer-in-charge of work. | Each | 29322.3 | 29322.3 | 5.0 | False | None | None | False | None | False | 146611.5 | 0 | 3220971 | 111017 | None | 084 | Providing and placing on terrace, polyethylene water storage tanks with manhole lid and suitable locking arrangements, making holes of suitable diameter for inlet, outlet and over flow pipes, including cost of all materials, labour, transport charges, HOM of equipments and testing complete as per specifications with all lead and lifts etc., complete and as directed by the Engineer-in-charge of work. | Ltr | 9.45 | 9.45 | 1000.0 | False | None | None | False | None | False | 9450.0 | 0 | 3220972 | 111017 | None | 085 | 25mm Normal gauge polythene bore pipes | m | 56.7 | 56.7 | 300.0 | False | None | None | False | None | False | 17010.0 | 0 | 3220973 | 111017 | None | 086 | Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark with all lead and lifts etc., complete and as directed by the Engineer-in-charge of work. | Each | 932.4 | 932.4 | 10.0 | False | None | None | False | None | False | 9324.0 | 0 | 3220974 | 111017 | None | 087 | Providing and fixing brass bib cock of approved quality :20 mm nominal bore with all lead and lifts etc., complete and as directed by the Engineer-in-charge of work | Nos | 320.25 | 320.25 | 20.0 | False | None | None | False | None | False | 6405.0 | 0 |
|
|
---|