createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1717765167732
version3
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee3870.00
emd275000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose21-06-2024 16:30:00
tenderQueryClose18-06-2024 16:30:00
technicalBidOpen24-06-2024 17:00:00
publishedDate10-06-2024 13:30:00
publishedByPostRDPR_EE_DIV_RCR
publishedByUserKPE14312 - VENKATESH GALAG
bidValidityPeriod90
noOfCalls1
preBidMeetingDate14-06-2024 11:00:00
preBidMeetingYnTrue
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonMd. Faiz Alam
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumberNone
mobileNumber9972094236
tenderSupplierListNone
tenderSchedule
createdTs1717765167781
version4
createdDateNone
modifiedDateNone
tenderNumberRDPR/2024-25/BD/WORK_INDENT5677
titleConstruction of New School Room, Compound wall and Toilet to Govt High School Building at Hemanur village in Deodurga Taluka of Raichur District. Under KKRDB for the year 2023-24
descriptionConstruction of New School Room, Compound wall and Toilet to Govt High School Building at Hemanur village in Deodurga Taluka of Raichur District. Under KKRDB for the year 2023-24
categoryWORKS
categoryTextWorks
ecv15456302.43
deptNameRural Development and Panchayat Raj Department
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnTrue
location963
locationNameRDPR Division Office Raichur
provisionalAmount18323000.0
groupOverheadTotal0.0
fileNumberEE/PRED/JE-1/KKRDB/MICRO/2023-24/HEMANUR/DEODURGA
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17177651680000NoneNoneBuildingsFor School Building Ground Floor13474178.92
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3248120112383None001Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. (PWD CSR VOL I for the year 2023-24. I. No. 1.12 P.No. 08)Cum99.7599.75194.4FalseNoneNoneFalseNoneFalse19391.40
3248121112383None002Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work (PWD CSR VOL I for the year 2023-24. I. No. 1.14.1 P.No. 08 )Cum107.1107.1967.05FalseNoneNoneFalseNoneFalse103571.0550
3248122112383None003Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m (PWD CSR VOL I for the year 2023-24. I. No. 1.4.1 P.No. 05)Cum254.1254.1139.11FalseNoneNoneFalseNoneFalse35347.8510
3248123112383None004Providing and Filling in foundation with granite / trap broken metal 100mm. And down size & with approved sand including hand packing, ramming, watering, including cost of all materials and labour with all lead and lift complete as per specifications. (PWD CSR VOL I for the year 2023-24. I. No. 1.23 P.No. 11)Cum2816.12816.1193.41FalseNoneNoneFalseNoneFalse544661.9010
3248124112383None005Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates (PWD CSR VOL I for the year 2023-24. I. No. 2.1.4 P.No. 15)Cum6527.856527.858.57FalseNoneNoneFalseNoneFalse55943.67450
3248125112383None006Addendum I Percentage Additionalities for Formwork, Centering & Scaffolding for RCC Beams, Lintels & Troughs of Aqueducts 60% (PWD CSR VOL I for the year 2023-24. Sl. No. 14 P.No. 112)Cum3916.713916.718.57FalseNoneNoneFalseNoneFalse33566.20470
3248126112383None007Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates. (PWD CSR VOL I for the year 2023-24. I. No. 2.1.3 P.No. 15)Cum6288.456288.4558.02FalseNoneNoneFalseNoneFalse364855.8690
3248127112383None008Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates. (PWD CSR VOL I for the year 2023-24. I. No. 2.1.3 P.No. 15) for Flooring bed concreteCum6288.456288.4557.04FalseNoneNoneFalseNoneFalse358693.1880
3248128112383None009Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates. (PWD CSR VOL I for the year 2023-24. I. No. 2.1.3 P.No. 15) for PCC Below bed concreteCum6288.456288.456.98FalseNoneNoneFalseNoneFalse43893.3810
3248129112383None010Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates. (PWD CSR VOL I for the year 2023-24. I. No. 2.1.3 P.No. 15) for flagging concreteCum6288.456288.458.88FalseNoneNoneFalseNoneFalse55841.4360
3248130112383None011Filling approved earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum454.65454.651128.82FalseNoneNoneFalseNoneFalse513218.0130
3248131112383None012Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (PWD CSR VOL I for the year 2023-24. I. No. 2.2.3 P.No. 15)Cum6652.86652.8177.13FalseNoneNoneFalseNoneFalse1178410.4640
3248132112383None013Addendum I Percentage Additionalities for Formwork, Centering & Scaffolding for Stepped footings 8%. (PWD CSR VOL I for the year 2023-24. Sl. No. 1(b) P.No. 111)Cum532.22532.22177.13FalseNoneNoneFalseNoneFalse94272.12860
3248133112383None014Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (PWD CSR VOL I for the year 2023-24. I. No. 2.2.3 P.No. 15)Cum6652.86652.87.99FalseNoneNoneFalseNoneFalse53155.8720
3248134112383None015Addendum I Percentage Additionalities for Formwork, Centering & Scaffolding for RCC Columns / Shaft (Slip Centering) 70% (PWD CSR VOL I for the year 2023-24. Sl. No. 9 P.No. 111)Cum6652.86652.844.28FalseNoneNoneFalseNoneFalse294585.9840
3248135112383None016Addendum I Percentage Additionalities for Formwork, Centering & Scaffolding for RCC Columns / Shaft (Slip Centering) 50% (PWD CSR VOL I for the year 2023-24. Sl. No. 9 P.No. 111)Cum3326.43326.444.28FalseNoneNoneFalseNoneFalse147292.9920
3248136112383None017Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(PWD CSR VOL I for the year 2023-24. I. No. 2.5.2 P.No. 16)Cum7185.157185.1522.27FalseNoneNoneFalseNoneFalse160013.29050
3248137112383None018Addendum I Percentage Additionalities for Formwork, Centering & Scaffolding for RCC Columns / Shaft (Slip Centering) 70% (PWD CSR VOL I for the year 2023-24. Sl. No. 9 P.No. 111)Cum5029.615029.6122.27FalseNoneNoneFalseNoneFalse112009.41470
3248138112383None019Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(PWD CSR VOL I for the year 2023-24. I. No. 2.5.2 P.No. 16)Cum7185.157185.157.38FalseNoneNoneFalseNoneFalse53026.4070
3248139112383None020Addendum I Percentage Additionalities for Formwork, Centering & Scaffolding for RCC Beams, Lintels & Troughs of Aqueducts 60% (PWD CSR VOL I for the year 2023-24. Sl. No. 14 P.No. 112)Cum4311.094311.097.38FalseNoneNoneFalseNoneFalse31815.84420
3248140112383None021Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(PWD CSR VOL I for the year 2023-24. I. No. 2.5.2 P.No. 16)Cum7185.157185.1526.1FalseNoneNoneFalseNoneFalse187532.4150
3248141112383None022Addendum I Percentage Additionalities for Formwork, Centering & Scaffolding for RCC Beams, Lintels & Troughs of Aqueducts 60% (PWD CSR VOL I for the year 2023-24. Sl. No. 14 P.No. 112)Cum4311.094311.0926.1FalseNoneNoneFalseNoneFalse112519.4490
3248142112383None023Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(PWD CSR VOL I for the year 2023-24. I. No. 2.5.2 P.No. 16)Cum7185.157185.1597.03FalseNoneNoneFalseNoneFalse697175.10450
3248143112383None024Addendum I Percentage Additionalities for Formwork, Centering & Scaffolding for RCC Roof Slabs 50% (PWD CSR VOL I for the year 2023-24. Sl. No. 15 P.No. 112)Cum3592.583592.5897.03FalseNoneNoneFalseNoneFalse348588.03740
3248144112383None025Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(PWD CSR VOL I for the year 2023-24. I. No. 2.5.2 P.No. 16) ChajjaCum7185.157185.152.52FalseNoneNoneFalseNoneFalse18106.5780
3248145112383None026Addendum I Percentage Additionalities for Formwork, Centering & Scaffolding for Chejjas, Canopy & Other Architectural projections of minor sections 45% (PWD CSR VOL I for the year 2023-24. Sl. No. 19 P.No. 112)Cum3233.323233.322.52FalseNoneNoneFalseNoneFalse8147.96640
3248146112383None027Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. (PWD CSR for Buildings VOL II for the year 2023-24. I. No. 6.32 P.No. 17)Sqm1375.51375.576.54FalseNoneNoneFalseNoneFalse105280.770
3248147112383None028Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. (PWD CSR for Buildings VOL II for the year 2023-24. I. No. 6.32 P.No. 17)Sqm1375.51375.5517.13FalseNoneNoneFalseNoneFalse711312.3150
3248148112383None029Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 6.34 P.No. 17)Sqm1159.21159.260.14FalseNoneNoneFalseNoneFalse69714.2880
3248149112383None030Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 6.16 P.No. 15)Sqm99.7599.7560.14FalseNoneNoneFalseNoneFalse5998.9650
3248150112383None031Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (PWD CSR for Buildings VOL II for the year 2023-24. I. No. 8.1.2 P.No. 41)Sqm253.05253.05873.43FalseNoneNoneFalseNoneFalse221021.46150
3248151112383None032Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 8.2.2 P.No. 41) OUTSIDE PLASTERINGSqm292.95292.95937.55FalseNoneNoneFalseNoneFalse274655.27250
3248152112383None033Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 8.2.2 P.No. 41) ROUGH PLASTERINGSqm292.95292.95190.78FalseNoneNoneFalseNoneFalse55889.0010
3248153112383None034Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 8.51 P.No. 50)Sqm105.0105.01459.67FalseNoneNoneFalseNoneFalse153265.350
3248154112383None035Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 12.13.1 P.No. 100)Cum103755.75103755.751.32FalseNoneNoneFalseNoneFalse136957.590
3248155112383None036Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 12.54 P.No. 104)Sqm333.9333.934.2FalseNoneNoneFalseNoneFalse11419.380
3248156112383None037Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per specification. 35 mm thick both side commercial (PWD CSR VOL I for the year 2023-24. I. No. 12.57.6 P.No. 105)Sqm3488.13488.137.97FalseNoneNoneFalseNoneFalse132443.1570
3248157112383None038Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) (PWD SR for Buildings VOL II for the year 2023-24. I. No. 12.90 P.No. 110)Sqm7070.77070.754.0FalseNoneNoneFalseNoneFalse381817.80
3248158112383None039Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 12.60 P.No. 105)Nos1104.61104.632.0FalseNoneNoneFalseNoneFalse35347.20
3248159112383None040Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : 125x64x1.90mm (PWD SR for Buildings VOL II for the year 2023-24. I. No. 12.74.1 P.No. 107)Nos107.1107.196.0FalseNoneNoneFalseNoneFalse10281.60
3248160112383None041Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 12.58 P.No. 105)Nos126.0126.032.0FalseNoneNoneFalseNoneFalse4032.00
3248161112383None042Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. complete (PWD SR for Buildings VOL II for the year 2023-24. I. No. 12.62 P.No. 105)Nos248.85248.8532.0FalseNoneNoneFalseNoneFalse7963.20
3248162112383None043Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete (PWD SR for Buildings VOL II for the year 2023-24. I. No. 12.63 P.No. 105)Nos136.5136.532.0FalseNoneNoneFalseNoneFalse4368.00
3248163112383None044Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges. with both side prelam (PWD CSR VOL I for the year 2023-24. I. No. 12.55.1 P.No. 104)Sqm2484.32484.39.45FalseNoneNoneFalseNoneFalse23476.6350
3248164112383None045Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) (PWD SR for Buildings VOL II for the year 2023-24. I. No. 12.85 P.No. 109)Sqm6004.956004.955.04FalseNoneNoneFalseNoneFalse30264.9480
3248165112383None046Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications.(PWD SR for Buildings VOL II for the year 2023-24. I. No. 12.51 P.No. 104)Nos1055.01055.016.0FalseNoneNoneFalseNoneFalse16880.00
3248166112383None047Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 11.34B P.No. 86)Kg192.15192.151239.84FalseNoneNoneFalseNoneFalse238235.2560
3248167112383None048Flooring with 25mm thick polished tandur blue stone slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab, , including cost of materials, labour, curing, polishing complete as per specificationsSqm1622.251622.25369.69FalseNoneNoneFalseNoneFalse599729.60250
3248168112383None049Flooring with 25mm thick polished tandur blue stone slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab, , including cost of materials, labour, curing, polishing complete as per specifications for Tandur blue skritingSqm1622.251622.2519.76FalseNoneNoneFalseNoneFalse32055.660
3248169112383None050Providing and laying Black Lapotra Granite stone flooring in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.(PWD SR for Buildings VOL II for the year 2023-24. I. No. 9.32 P.No. 64)Sqm2711.12711.1150.0FalseNoneNoneFalseNoneFalse406665.00
3248170112383None051Providing and laying Black Lapotra Granite stone flooring in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.(PWD SR for Buildings VOL II for the year 2023-24. I. No. 9.32 P.No. 64)Sqm2711.12711.113.91FalseNoneNoneFalseNoneFalse37711.4010
3248171112383None052Providing edge moulding to 18mm thick Granite stone counters, vanities etc including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-charge. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 10.2 P.No. 69)m344.4344.429.51FalseNoneNoneFalseNoneFalse10163.2440
3248172112383None053Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 9.11 P.No. 60)Sqm933.45933.4547.82FalseNoneNoneFalseNoneFalse44637.5790
3248173112383None054Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 9.39 P.No. 65)Sqm1521.451521.4572.14FalseNoneNoneFalseNoneFalse109757.4030
3248174112383None055Painting wood work with Deluxe Multi Surface Paint of required shade. Two coat applied @ 0.90L/10 m² over an under coat of primer applied @0.75 L/10 m² of approved brand and manufacture to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-chargeSqm144.9144.980.64FalseNoneNoneFalseNoneFalse11684.7360
3248175112383None056Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @ 0.80 ltr/10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 8.33.3 P.No. 47)Sqm145.95145.9574.84FalseNoneNoneFalseNoneFalse10922.8980
3248176112383None057Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Special primer applied @ 0.75 ltr /10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 8.33.1 P.No. 46)Sqm165.9165.9873.43FalseNoneNoneFalseNoneFalse144902.0370
3248177112383None058Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. M.S. tube including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Kg144.9144.9331.8FalseNoneNoneFalseNoneFalse48077.820
3248178112383None059Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Special primer applied @ 0.75 ltr /10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 8.33.1 P.No. 46)Sqm165.9165.9586.24FalseNoneNoneFalseNoneFalse97257.2160
3248179112383None060Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67L/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm182.7182.7937.55FalseNoneNoneFalseNoneFalse171290.3850
3248180112383None061Providing wall black boards in 12mm thick with CM 1:3 and applied with primer & two coats of acrylic emulsion black paint including finishing etc.,complete. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 8.84 P.No. 55)Sqm498.75498.7518.0FalseNoneNoneFalseNoneFalse8977.50
3248181112383None062Lettering with black Japan paint of approved brand and manufacture to give an even shade including preparing the surface after thoroughly cleaning the surface to remove all dirt, dust and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (PWD SR for Buildings VOL II for the year 2023-24. I. No. 8.49 P.No. 49)cm4.24.23000.0FalseNoneNoneFalseNoneFalse12600.00
3248182112383None063Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. a.Buildings (PWD CSR VOL I for the year 2023-24. I. No. 2.11.a P.No. 18)Tonne93929.8593929.8535.513FalseNoneNoneFalseNoneFalse3335730.763050
3248183112383None064Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. (PWD CSR VOL I for the year 2023-24. I. No. 1.8 P.No. 7)Cum497.7497.7198.0FalseNoneNoneFalseNoneFalse98544.60
3248184112383None065Addendum I Percentage Additionalities for Formwork, Centering & Scaffolding for RCC Columns / Shaft (Slip Centering) 70% (PWD CSR VOL I for the year 2023-24. Sl. No. 9 P.No. 111)Cum4656.964656.967.9904FalseNoneNoneFalseNoneFalse37210.9731840
17177651680000NoneNoneBuildingsFor Water supply and Saintation Works945702.98
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3248185112384None001Water purification plants: Supplying, Installation and Commissioning of automatic Water purification plant (RO+UF) with all accessories piping, product water tank on single phase power supply as per the enclosed detailed Technical Specifications including cost of material, loading and unloading and as directed by the Engineer in charge. (Ref- detailed specification enclosed seperatly). Note:- 1.The above rates mentioned are only for the preparation of estimate purpose. 2. All items are to be of BSI /NFS standards,with BSI / NFS mark . 3. Tenders to be invited for procurement. 4. No direct payment should be made under any situation or condition or on any account. 5. After commissioning of plant necessary testing to be done for the satisfactory of Engineer Incharge. Note : Refer the ANNEXURE : F for Detailed Specification of Each componentsEach26250.026250.01.0FalseNoneNoneFalseNoneFalse26250.00
3248186112384None002Providing and placing on terrace (at all floor levels), polyethylene water storage tanks IS: 12701 marked, with cover and suitable locking arrangements and making necessary holes for inlet, outlet and over flow pipes but without fittings and the base support for tankLtr9.459.456000.0FalseNoneNoneFalseNoneFalse56700.00
3248187112384None003Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS 15778 having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, this includes jointing of pipes and fittings with one step solvent cement, trenching, refilling & testing of joints complete. (external work). 40MM Dia Pipe over terrace distribution from TankMtr500.85500.85150.0FalseNoneNoneFalseNoneFalse75127.50
3248188112384None004Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS 15778 having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, this includes jointing of pipes and fittings with one step solvent cement, trenching, refilling & testing of joints complete. (external work). 32mm dia Pipe from Terrace Floor to Toilet RoomsMtr390.6390.6150.0FalseNoneNoneFalseNoneFalse58590.00
3248189112384None005Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS 15778 having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, this includes jointing of pipes and fittings with one step solvent cement, trenching, refilling & testing of joints complete. (external work). 25mm dia Pipe from Toilet Rooms to Bath,W/C,urinals & WashbasinsMtr500.85500.85150.0FalseNoneNoneFalseNoneFalse75127.50
3248190112384None006Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS 15778 having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, this includes jointing of pipes and fittings with one step solvent cement, trenching, refilling & testing of joints complete. (external work). 20mm dia Pipe from Toilet Rooms to Bath,W/C,urinals & WashbasinsMtr397.95397.95150.0FalseNoneNoneFalseNoneFalse59692.50
3248191112384None007Providing and fixing brass bib cock of approved quality : 15 mm nominal boreEach300.3300.330.0FalseNoneNoneFalseNoneFalse9009.00
3248192112384None008Providing and fixing brass stop cock of approved quality : 20 mm nominal bore 40mm nominal dia near tank outletEach320.25320.2510.0FalseNoneNoneFalseNoneFalse3202.50
3248193112384None009Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a single 15mm C.P. brass pillar tapUnit2689.052689.0510.0FalseNoneNoneFalseNoneFalse26890.50
3248194112384None010Providing and fixing unplasticised PVC connection pipe with brass unions : 20 mm nominal boreSet115.5115.510.0FalseNoneNoneFalseNoneFalse1155.00
3248195112384None011Providing and fixing granite stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in- charge and finished smooth.Sqm2928.452928.4528.08FalseNoneNoneFalseNoneFalse82230.8760
3248196112384None012Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot restsEach5128.25128.26.0FalseNoneNoneFalseNoneFalse30769.20
3248197112384None013Providing and fixing PVC (S.W.R) Nahani Trap 10cms x 10cms with all fitting arrangements & all necessary accessories completeNo231.0231.025.0FalseNoneNoneFalseNoneFalse5775.00
3248198112384None014Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work.In ordinary/soft rock without blasting upto 1.5 m depthCum381.15381.1546.8FalseNoneNoneFalseNoneFalse17837.820
3248199112384None015Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: Inside dimensions 455x610 mm and 45 cm deep for single pipe line : WithNo5924.15924.112.0FalseNoneNoneFalseNoneFalse71089.20
3248200112384None016Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 150mm nominal dia pipesMtr806.4806.440.0FalseNoneNoneFalseNoneFalse32256.00
3248201112384None017Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 110mm nominal dia pipesMtr404.25404.25120.0FalseNoneNoneFalseNoneFalse48510.00
3248202112384None018Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 110mm nominal dia pipesMtr404.25404.25120.0FalseNoneNoneFalseNoneFalse48510.00
3248203112384None019Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 100 mm diameterm305.55305.5596.0FalseNoneNoneFalseNoneFalse29332.80
3248204112384None020Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. - Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregatesCum6288.456288.452.0FalseNoneNoneFalseNoneFalse12576.90
3248205112384None021Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.Sqm1375.51375.523.19FalseNoneNoneFalseNoneFalse31897.8450
3248206112384None022Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.Sqm1375.51375.515.6FalseNoneNoneFalseNoneFalse21457.80
3248207112384None023Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.Sqm1159.21159.25.4FalseNoneNoneFalseNoneFalse6259.680
3248208112384None024Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum7185.157185.151.52FalseNoneNoneFalseNoneFalse10921.4280
3248209112384None025Addendum I Percentage Additionalities for Formwork, Centering & Scaffolding for RCC Roof Slabs 50%Cum3592.583592.5815.15FalseNoneNoneFalseNoneFalse54427.5870
3248210112384None026Providing 20 mm cement plaster of mix :1:6 (1 cement: 6 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm349.65349.6515.6FalseNoneNoneFalseNoneFalse5454.540
3248211112384None027Providing 20 mm cement plaster of mix :1:6 (1 cement: 6 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm349.65349.6520.8FalseNoneNoneFalseNoneFalse7272.720
3248212112384None028Providing & fixing 455x610 mm cast iron cover with frame weight to be not less 38kgs (weight of cover 23 kgs and weight of frame 15 kgs)and necessary locking arrangements with M.S flats 32x6 mm etc & painting with two or more coats with black Japan paint etc. complete as directed by the engineer-in-charge.Each2060.12060.11.0FalseNoneNoneFalseNoneFalse2060.10
3248213112384None029Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.Tonne93929.8593929.850.1FalseNoneNoneFalseNoneFalse9392.9850
3248214112384None030Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required :Each8642.08642.03.0FalseNoneNoneFalseNoneFalse25926.00
17177651680000NoneNoneBuildingsFor Water Storage Sump221599.53
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3248215112385None001Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the workCum107.1107.1100.0FalseNoneNoneFalseNoneFalse10710.00
3248216112385None002Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregatesCum6288.456288.453.75FalseNoneNoneFalseNoneFalse23581.68750
3248217112385None003Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specificationsM25 Design Mix Using 20 mm nominal size graded crushed coarse aggreCum6652.86652.83.22FalseNoneNoneFalseNoneFalse21422.0160
3248218112385None004Addendum I Percentage Additionalities for Formwork, Centering & Scaffolding for RCC Roof Slab 50% (PWD CSR VOL I for the year 2023-24. Sl. No. 9 P.No. 111)Cum3326.43326.43.22FalseNoneNoneFalseNoneFalse10711.0080
3248219112385None005Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum6652.86652.85.4FalseNoneNoneFalseNoneFalse35925.120
3248220112385None006Addendum I Percentage Additionalities for Formwork, Centering & Scaffolding for Earth Retaining structures 10% (PWD CSR VOL I for the year 2023-24. Sl. No. 11 P.No. 112)Cum665.28665.285.4FalseNoneNoneFalseNoneFalse3592.5120
3248221112385None007Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-chargeSqm389.55389.5554.0FalseNoneNoneFalseNoneFalse21035.70
3248222112385None008Providing and laying water proofing treatment to the Water tanks & Liquid Retaining structures with two component acrylic polymer modified cementitious waterproofing membrane with minimum elongation of 50% applied @ 1.5 kg/m2 for internal side waterproofing in two layers with waiting period of 4-6 hrs per layer and food grade epoxy coating in two coats certified by CFTRI Mysuru, including surface preparation completely as per specification.Sqm532.35532.3536.0FalseNoneNoneFalseNoneFalse19164.60
3248223112385None009Providing & fixing 455x610 mm cast iron cover with frame weight to be not less 38kgs (weight of cover 23 kgs and weight of frame 15 kgs)and necessary locking arrangements with M.S flats 32x6 mm etc & painting with two or more coats with black Japan paint etc. complete as directed by the engineer-in-charge.Each2060.12060.11.0FalseNoneNoneFalseNoneFalse2060.10
3248224112385None010Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification for BuildingsTonne93929.8593929.850.7814FalseNoneNoneFalseNoneFalse73396.784790
17177651680000NoneNoneBuildingsFor Drilling of Borwell work100676.1
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3248225112386None001Geophysical investigation at site for sinking borewells for providing drinking water to the habitation either through the Hand Pump MWS or P.W.S.S, by vertical electrical sounding by adopting Venner or Schlumbergers’s method, including reconnaissance survey of geological formation. Geophysical investigation of existing ground water in the vicinity, its quality, quantity and acceptability of the users, indicating the location of the site, recommended depth of casing pipe required to seal the top unconsolidated formation including an extra depth of 1.0 metre in consolidated formation for proper seating of casing pipe, depth of drilling required to cover full depth of aquifer proposed to be tapped, probable yield and other information required including transportation of instruments and accessories to work site, engaging technical personal and labour required etc. NOTE: 1) Additional rate on item 1&2 is allowed for drilling in over burden and fixing Casing pipes beyond 20 M (for fixing Casing pipes only) a) Above 20 M and upto 30 M - 15%, b) Above 30 M - 30% (Measurement of overburden is restricted to the depth of casing pipe fixed excluding initial depth of 20M and projection above ground level). 2) A sum of Rs. 100/- is to be deducted for Dry Borewell towards yield test. (WS & Sewerage Works Vol V CSR for the 2023-24 Sl No. 12.4 ,P No-140) Geophysical investigationEach5552.45552.44.0FalseNoneNoneFalseNoneFalse22209.60
3248226112386None002Sinking borewell of 150mm dia. clear, using super fast hydraulic rig of capacity 250 PSIG & above 900 CMF and above, in all strata of earth, including over burden upto 20M, fixing of casing pipes, collars and cap with ncessary cutting, threading and welding including transportation of rig and supporting vehicles, crew charges, cost of consumables, cost of yield test at the final depth with a minimum working of compressor for one hour etc. complete. The cost excludes the cost of casing pipes, collars and caps etc.) for: (Above 300m of drilling add 10% for every 50m depth) (WS & Sewerage Works Vol V CSR for the 2023-24 Sl No. 12.2 ,P No-139) Borewell depth of 0 to 50 mm324.45324.4550.0FalseNoneNoneFalseNoneFalse16222.50
3248227112386None003Sinking borewell of 150mm dia. clear, using super fast hydraulic rig of capacity 250 PSIG & above 900 CMF and above, in all strata of earth, including over burden upto 20M, fixing of casing pipes, collars and cap with ncessary cutting, threading and welding including transportation of rig and supporting vehicles, crew charges, cost of consumables, cost of yield test at the final depth with a minimum working of compressor for one hour etc. complete. The cost excludes the cost of casing pipes, collars and caps etc.) for: (Above 300m of drilling add 10% for every 50m depth) (WS & Sewerage Works Vol V CSR for the 2023-24 Sl No. 12.2 ,P No-139) Borewell depth of 50 to 100 mm406.35406.3550.0FalseNoneNoneFalseNoneFalse20317.50
3248228112386None004Sinking borewell of 150mm dia. clear, using super fast hydraulic rig of capacity 250 PSIG & above 900 CMF and above, in all strata of earth, including over burden upto 20M, fixing of casing pipes, collars and cap with ncessary cutting, threading and welding including transportation of rig and supporting vehicles, crew charges, cost of consumables, cost of yield test at the final depth with a minimum working of compressor for one hour etc. complete. The cost excludes the cost of casing pipes, collars and caps etc.) for: (Above 300m of drilling add 10% for every 50m depth) (WS & Sewerage Works Vol V CSR for the 2023-24 Sl No. 12.2 ,P No-139) Borewell depth of 100 to 150 mm432.6432.650.0FalseNoneNoneFalseNoneFalse21630.00
3248229112386None005Supply of ISI mark 175mm nominal bore,plain and steel casing pipe grade of steel Fe 410 of wall thickness conforming to IS 4270-2001 and latest ammendments, electrical resistance welded steel tubes, material and conforming to IS 1387-1993 and manufactured by basic open hearth electric or basic oxygen process in random length of 5-7m both ends.threaded conforming to IS 554-1985 one end fixed with socket conforming to IS 4270-2001 and the other end with screwed pipes all shall be responsibaly free from defects. The tubes shall be responsible straight end should be with ISI marking weighing 25.10kg/m.prices include Collar-Medium duty.(WS & Sewerage Works Vol V CSR for the 2023-24 Sl No. 12.32 ,P No-143)m2029.652029.6510.0FalseNoneNoneFalseNoneFalse20296.50
17177651680000NoneNoneBuildingsFor Pumping Machinery Work81832.8
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3248230112387None001Providing, Single Phase Submersible Pump Sets of 100mm dia (4 inch) suitable for bore well confirming to IS 8034-2000 specifications, to work site with testing of as per instructions of engineer incharge of work and latest amendments etc. complete.Each10678.510678.51.0FalseNoneNoneFalseNoneFalse10678.50
3248231112387None002Supply and delivery at site Brand new best make PVC insulated cable of Flat 3 core (sheathed) of nominal cross sectional area as per IS 694-1990 with ISI Mark and as per its latest amendments. (1X3X4 m2)Mtr141.75141.75150.0FalseNoneNoneFalseNoneFalse21262.50
3248232112387None003Supply and delivery at site of brand new best make pressure gauge bourdon type as per IS 778/1984 with ISI Mark and as per its latest amendments. a.63mmEach436.8436.81.0FalseNoneNoneFalseNoneFalse436.80
3248233112387None004Supply and delivery at site of brand new best make non-return valve as per IS 778/1984 with ISI Mark and as per its latest amendments size 50mmEach1312.51312.51.0FalseNoneNoneFalseNoneFalse1312.50
3248234112387None005Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOLDirect Online Starter 2) S-D- Star Delta Starter Outdoor type Board: upto 6 HPEach6825.06825.01.0FalseNoneNoneFalseNoneFalse6825.00
3248235112387None006Supply and delivery at site best indigenous brand new power capacitor as per IS 2834/1986 with latest amendments with KPTCL authorities and erection, electrification and commissioning of the same at the location of respective pump sets.Kvar577.5577.53.0FalseNoneNoneFalseNoneFalse1732.50
3248236112387None007Supply and delivery at site delivery of best indigenous brand new MCB (Miniature Circuit Breakers) of required capacity as per IS 88228/1978 and its latest amendments and with ISI Mark of 6/10/16/20/25/40 Amps with scalable box.Per 3 Poles1207.51207.51.0FalseNoneNoneFalseNoneFalse1207.50
3248237112387None008Supplying, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc. Note: Upto 110mm dia Coil shall be used. For Grade PE80 PN6.0 : PE80 (PN 6.0 / 6 Kg/cm2) a. 63mmMtr150.15150.15150.0FalseNoneNoneFalseNoneFalse22522.50
3248238112387None009Labour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all items including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges,tools and equipments etc., involved in the job as per specifications, with necessary tests as per specifications, with testing of as per instructions of engineer incharge of work.Job6825.06825.01.0FalseNoneNoneFalseNoneFalse6825.00
3248239112387None010Labour charges for erection of indoor type panel board and meter board units with all necessary materials and labour tools and equipments including cement concrete for foundation/bed etc,complete as per specification, with testing of as per instructions of engineer incharge of work.Job1417.51417.51.0FalseNoneNoneFalseNoneFalse1417.50
3248240112387None011Providing,Supplying and fixing suitable for 1.1 KV class UG cable filled with necessary bitumen insulating compound complete with terminals clamps,bolts,nuts and washers etc. with necessary materials and labour tools and equipments as per instructions of engineer incharge of work.Each472.5472.51.0FalseNoneNoneFalseNoneFalse472.50
3248241112387None012Supply and delivery of galvanized mild steel tubes of 6mtr standard length heavy duty (C Class) as per IS 1239 (Part-I) 1990 with latest amendments with ISI Mark (one end fitted with Heavy Duty collar and other end fitted with protective cover) a.50 mmEach3202.53202.51.0FalseNoneNoneFalseNoneFalse3202.50
3248242112387None013Earthing: Supplying and fixing and wiring earth electrode for grounding circuits IC cutouts and other equipments on the meter board in the pit. The pits should be filled up with equal proportion of salt and charcoal 150mm around the pipe to complete depth. The connection from the pipe to the conduits etc. is to established through GI wire of sizes as per clause 7.3.3 of IS 732 using 12mm bolts, nuts, washers and check nuts, the pipe shall have 16 through holes of 12mm dia.Job3937.53937.51.0FalseNoneNoneFalseNoneFalse3937.50
17177651680000NoneNoneBuildingsFor Electrification Works632312.1
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3248243112388None001Supplying heavy gauge PVC conduit pipe 19/20mm dia 2mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc., and fixing using inverted wood plugs in case of RCC ceiling and RCC wall / stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws.Mtr69.369.3850.0FalseNoneNoneFalseNoneFalse58905.00
3248244112388None002Supplying heavy gauge PVC conduit pipe 19/20mm dia 2mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc., and fixing using inverted wood plugs in case of RCC ceiling and RCC wall / stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws.25mm dia 2mm thickMtr81.981.9200.0FalseNoneNoneFalseNoneFalse16380.00
3248245112388None003Supplying heavy gauge PVC Conduit Pipe 19/20mm dia 2mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary.Mtr71.471.4280.0FalseNoneNoneFalseNoneFalse19992.00
3248246112388None004Supplying heavy gauge PVC Conduit Pipe 25mm dia 2mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary.Mtr82.9582.9575.0FalseNoneNoneFalseNoneFalse6221.250
3248247112388None005Supplying And Fixing Metal Fan Box with Round Hook.Each122.85122.8541.0FalseNoneNoneFalseNoneFalse5036.850
3248248112388None006Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2X1.5Sq.mm Cable confirming to the GTP without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet. GROUP A - Short point upto 3Mtr from tapping point to out let via switch boxPits282.45282.4542.0FalseNoneNoneFalseNoneFalse11862.90
3248249112388None007Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch boxPits397.95397.9558.0FalseNoneNoneFalseNoneFalse23081.10
3248250112388None008Long point above 6Mtr upto 10Mtr from tapping point to out let via switch boxPits582.75582.7512.0FalseNoneNoneFalseNoneFalse6993.00
3248251112388None009Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 - 1.5sqmmMtr27.327.31850.0FalseNoneNoneFalseNoneFalse50505.00
3248252112388None010Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 - 2.5sqmmMtr44.144.11850.0FalseNoneNoneFalseNoneFalse81585.00
3248253112388None011Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 - 4.0sqmmMtr66.1566.15200.0FalseNoneNoneFalseNoneFalse13230.00
3248254112388None012Supplying 6A flush type socket and 6 amps flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3654 - 6Amps 2 WayEach134.4134.44.0FalseNoneNoneFalseNoneFalse537.60
3248255112388None013Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 4-5 WayEach143.85143.8522.0FalseNoneNoneFalseNoneFalse3164.70
3248256112388None014Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 8-0 WayEach229.95229.9520.0FalseNoneNoneFalseNoneFalse4599.00
3248257112388None015Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 10-12 WayEach274.05274.0514.0FalseNoneNoneFalseNoneFalse3836.70
3248258112388None016Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. - 4-5 ModuleEach183.75183.7522.0FalseNoneNoneFalseNoneFalse4042.50
3248259112388None017Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. - 8-0 ModuleEach298.2298.220.0FalseNoneNoneFalseNoneFalse5964.00
3248260112388None018Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. - 10-12 ModuleEach361.2361.214.0FalseNoneNoneFalseNoneFalse5056.80
3248261112388None019Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 6Amps One way switch.Each107.1107.184.0FalseNoneNoneFalseNoneFalse8996.40
3248262112388None020Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 Stepped Fan Regulator Two ModuleEach374.85374.8526.0FalseNoneNoneFalseNoneFalse9746.10
3248263112388None021Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 - 16 A One Way SwitchEach189.0189.010.0FalseNoneNoneFalseNoneFalse1890.00
3248264112388None022Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 - 6/16 A Universal SocketEach247.8247.830.0FalseNoneNoneFalseNoneFalse7434.00
3248265112388None023Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 - TV / Telephone SocketEach163.8163.82.0FalseNoneNoneFalseNoneFalse327.60
3248266112388None024Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 - RJ 45/I.O Outlet Cat-6Each353.85353.8510.0FalseNoneNoneFalseNoneFalse3538.50
3248267112388None025Supplying of Switch disconnector fuse unit (TPN) HRC type (but without HRC fuses). With AC-23A duty and as per IS-13947. - 63AmpsEach2427.62427.61.0FalseNoneNoneFalseNoneFalse2427.60
3248268112388None026Supplying and fixing regular MCCB distribution Panel confirming to IS 8828, on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing of suitable type capacity MCCB's as an incomer for 3 phase Double door with necessary bus bar completely wired to use on 440Volts 3phase 4 wire powder coated painting etc., complete with a provision for fixing of single/three phase suitable capacity MCCB/MCB's as outgoings confirming to IS8828. 12 WayEach16305.4516305.452.0FalseNoneNoneFalseNoneFalse32610.90
3248269112388None027Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. - 6-32Amps SPEach435.75435.752.0FalseNoneNoneFalseNoneFalse871.50
3248270112388None028Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. - 5-32 Amps DPEach775.95775.952.0FalseNoneNoneFalseNoneFalse1551.90
3248271112388None029Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG MS enclosure.I - Single Door -12 Way SP &NEach1956.151956.152.0FalseNoneNoneFalseNoneFalse3912.30
3248272112388None030Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker [ELMCB] 240/450V up to 300mA sensitivity on existing wood/panel board. - 63 Amps 4 poleEach5822.255822.251.0FalseNoneNoneFalseNoneFalse5822.250
3248273112388None031Fabricating supplying and mounting MS box made out … SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete. - 14SWGSqm per Meter0.530.539500.0FalseNoneNoneFalseNoneFalse5035.00
3248274112388None032Supply and Installation / Fixing / Provision of Outdoor type Thermoplastic Modular Panel enclosure with transparent Polycarbonate Lid, shock proof, IP65 (Weather Proof), rust proof, dust proof, water proof, corrosion proof having internally Embedded gasket on both lid and flap suitable to fix Single Phase / Three Phase Energy Meter in suitable base plate and having a provision for Fuse / MCB cutout with suitable transparent hinged flap opening for operating MCB along with complete tamper proof SEALING facility. - 300mmx300mmx214mmEach4737.64737.61.0FalseNoneNoneFalseNoneFalse4737.60
3248275112388None033Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system.Each3133.23133.226.0FalseNoneNoneFalseNoneFalse81463.20
3248276112388None034Supplying exhaust fan of 1440 RPM of 300mm (12) size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply.Each3117.453117.456.0FalseNoneNoneFalseNoneFalse18704.70
3248277112388None035Supplying and drawing PVC flexible one pair telephone unarmoured tinned copper cable. - 2PairMtr22.0522.05200.0FalseNoneNoneFalseNoneFalse4410.00
3248278112388None036Supplying & fixing of I/O socket with back box Double I/oEach577.5577.510.0FalseNoneNoneFalseNoneFalse5775.00
3248279112388None037Supplying & Fixing of …mtrs Cat6 Patch Cable - 2mtrEach269.85269.8510.0FalseNoneNoneFalseNoneFalse2698.50
3248280112388None038Supplying & Fixing of Patch panel for LAN cabling - 16 Port 10/100 patch panelEach3202.53202.51.0FalseNoneNoneFalseNoneFalse3202.50
3248281112388None039Supplying and fixing of MDF krone junction box with KRONE Module / Telephone - cable termination. - 10 Pairm362.25362.255.0FalseNoneNoneFalseNoneFalse1811.250
3248282112388None040Supplying of .feet - PVC Batten with integrated LED tube .W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. -LED light fighting 1 x4'- 20/22 wEach724.5724.560.0FalseNoneNoneFalseNoneFalse43470.00
3248283112388None041Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with .W System Power consumption. LED Efficiency130lm/w, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Streetlight 40wattsEach4225.24225.21.0FalseNoneNoneFalseNoneFalse4225.20
3248284112388None042Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. - On wall / ceiling / Rafter / GirdersEach128.1128.146.0FalseNoneNoneFalseNoneFalse5892.60
3248285112388None043Fixing halogen/metal halide / SVL / IL / LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires.Each170.1170.11.0FalseNoneNoneFalseNoneFalse170.10
3248286112388None044Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S' hook with fan regulator to the existing board together with supplying and fixing 5 amps. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring.Each179.55179.5541.0FalseNoneNoneFalseNoneFalse7361.550
3248287112388None045Fixing one exhaust fan in the nitch already left in the wall with bolts and nuts and 5 amps. ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire.Each516.6516.66.0FalseNoneNoneFalseNoneFalse3099.60
3248288112388None046Supplying of 1.1 KV LT UG cable having aluminum conductor PVC insulated, extruded inner sheathed, galvanized, steel strip (except 2CX10Sq.mm wire armoured) confirming to IS-3975:1990 (No. of Strip indicated in GTP) & extruded PVC outer sheathed armoured cable with specified IS-1554 Part-1:1988 2 core 16 sqmmKm92838.992838.90.08FalseNoneNoneFalseNoneFalse7427.1120
3248289112388None047Supplying of 1.1 KV LT UG cable having aluminum conductor PVC insulated, extruded inner sheathed, galvanized, steel strip (except 2CX10Sq.mm wire armoured) confirming to IS-3975:1990 (No. of Strip indicated in GTP) & extruded PVC outer sheathed armoured cable with specified IS-1554 Part-1:1988 2 core 6 sqmmKm66576.366576.30.02FalseNoneNoneFalseNoneFalse1331.5260
3248290112388None048Labour charges for laying of 1.1 KV class UG cable in existing trench GI pipe / stoneware pipe / on wall / on pole as required.In existing trench/duct. 2.5 sqmm to 25 sqmmKm1246.351246.350.1FalseNoneNoneFalseNoneFalse124.6350
3248291112388None049Earth work Excavation for cable trench of 0.5m to 0.75 mtr width and Depth upto 1 Mtrs including trial pits, depositing on bank upto a lead of 50 Mtrs , Supplying and Displaying necessary Danger Boards and Lighting , Using sight Rails and Sign Boards at every 100 Mtrs wherever necessary as directed. In soil (Ordinary) (1x70x0.50x0.75 = 26.25 CMT)cm273.0273.026.25FalseNoneNoneFalseNoneFalse7166.250
3248292112388None050Providing and filling sand in excavated trench to cover already laid UG cable to a depth of 150mm all-round the cable. (1x70x0.50x0.75 = 26.25 CMT)cm60.960.926.25FalseNoneNoneFalseNoneFalse1598.6250
3248293112388None051Supplying and fixing Trivector Meter suitable for operation LT operation and -CT operated meter in polycarbonate body in class 0.5 accuracy as per IS 14697 and completely wired.Each4609.54609.51.0FalseNoneNoneFalseNoneFalse4609.50
3248294112388None052Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc. using 40mm dia 2.9mm thick 2.5 mtr long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode. The funnel should be enclosed in a CC chamber of 400x400x400mm with a cast iron cover. The earth electrode shall have staggered holes of 12mm dia and the electrode should be covered 150mm all-round with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts.Each4468.84468.84.0FalseNoneNoneFalseNoneFalse17875.20
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17177651690000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17177651690000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17177651690000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17177651690000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17177651690000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
17177652060000NoneNoneELIGIBILITYQualifications of the tenderer required as mentioned in the Technical Bid KW-4 in General conditions 3 must be furnished.None
17177652120000NoneNoneELIGIBILITYTender of the contractor, who have not completed the work in time, not executed the agreement in time in any other cases in this Division as per Clause 3.4 of Standard Tender Document and practices as mentioned in clause 25 of the standard tender document will not be accepted.None
17177652160000NoneNoneELIGIBILITYThe undersigned reserves the right to accept any or all tenders without assigning any reason.None
17177652270000NoneNoneELIGIBILITYContractor should execute the work by procuring cement, steel any other materials/Machinery for the work on their own and necessary quality test certificate should be produced and approval of the same.None
17177652310000NoneNoneELIGIBILITYOther details can be seen in the tender documentsNone
17177652350000NoneNoneELIGIBILITYContractors should have to upload the Scan copy of all necessary Qualification Documents/ Certificates, and submitted duly attested by notary while tender Evaluvation in this DivisionNone
17177652390000NoneNoneELIGIBILITYThe Department is not responsible for any delay in accessing e-procurement portal.None
17177652430000NoneNoneELIGIBILITYTenderer shall note that the Tenders of those found Eligible as mentioned in Clause 3 Qualification of Instructions to Tenders (ITT), will only be considered for evaluation.None
17177652490000NoneNoneELIGIBILITYContractors should have to upload the necessary Qualification details as Section 3 Clause 1.1 to 1.10 in prescribed formats of KW-4.None
17177652530000NoneNoneELIGIBILITYThe contractor should counter check all the designs of the scheme before execution / procurement of material and bring to the notice of the departmental officers for rectification.None
17177652660000NoneNoneELIGIBILITYThe contractors have to verify the designs and drawings prepared by the department and supplied for construction. correct the same for any mistakes and to submit it for the approval of the department prior to commencement of execution.None
17177652710000NoneNoneELIGIBILITYThe contractor should furnish the Contractor license CertificateNone
17177652770000NoneNoneELIGIBILITYSuccessful bidder submitting bids below the amount put to tender will be regularized to submit the difference amount in the form of FDR/TDR/DD/Pledge on the name of EE PRED Raichur within 20 days from the date of receiving the letter of acceptance. Failing which EMD will be forfeited and further action will be taken as per G O No FD PCL 2008 Bangalore Dated 14/10/2008. Cluase 25 of KW-4.None
17177652810000NoneNoneELIGIBILITYThe Building constructed under this programme shall be of high standard, requiring no major repairs for 3 years, The contractor shall furnish performance guarantee for 3 years as per clause and the performance guarantee will be released only after 3 years after completion of work.None
17177652850000NoneNoneELIGIBILITYThe Tenderer shall obtain the workdone certificate in the prescribed form from the competent authority not below the rank of Executive Engineer (District Level Officer) and scan the Original Certificate and attach the scanned file to the Bid. The Original Certificate / Certificates shall be produced whenever required.None
17177652900000NoneNoneELIGIBILITYThird party inspection is mandatory for all the works in this programmeNone
17177652940000NoneNoneELIGIBILITYThe work should be completed within the stipulated period from the date of agreement & The date of agreement itself is the date of commencement of the workNone
17177653050000NoneNoneELIGIBILITYThe work should be completed in 11 months (including mansoon)None
17177653090000NoneNoneELIGIBILITYThe defect liability period is 2 years and 3 years for major construction repairs.None
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid Electrical License for executing building electrificatio works and should have executed similar electrical works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneOwning the following key and critical equipment for this work (xxxx, xxxx, xxxx)NoneNone
NoneNoneNoneNoneTotal value of civl engineering works executed and payments received in the last five years (year-wise)NoneNone
NoneNoneNoneNoneList of existing commitments and ongoing worksNoneNone
NoneNoneNoneNoneList of works for which tenders already submittedNoneNone
NoneNoneNoneNoneBanker Details for referenceNoneNone
NoneNoneNoneNoneConstruction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneReports on the financial standing of the tenderer, such as profit and loss statements and auditor’s reports for the last five yearsNoneNone
NoneNoneNoneNoneQualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneList of Financial Resources with CertificatesNoneNone
NoneNoneNoneNoneMinimum financial turnover (civil engineering construction works) not less than two times the annual payments from this contract (Rs. 309.13 Lakhs)Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNoneSatisfactorily completed as prime contractor at-least one such similar work of value not less than Rs. 77.28 LakhsPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneExecuted in any one year the following minimum quantities of work (1. Earthwork & Constn of Embankment : 2374.07 Cum 2) PCC/RCC : 430.46 Cum 3) Steel- 29.11 Tone 4) SSM/BBM - 523.05 Cum, 5) Flooring - 442.69 Sqm, 6) Plastering- 1673.73 Sqm)Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneTenderer should possess valid licensePast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNonePWD Registration Certificate (Class I/II/III/IV)
NoneNoneNoneNoneLiquid assets and /or availability of credit facilities of no less than Rs. 42.15 LakhsCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneLine of Credit
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
PWD Contractor Registration CertificateTrueTechnical Bid
Previous Five years Financial Turn over 2019-20 to 2023-24TrueTechnical Bid
Similar nature Work done CertificateTrueTechnical Bid
Quantity wise Work done certificateTrueTechnical Bid
Line of credit Bank letter headTrueTechnical Bid
tenderWorkLocationList
tenderAddress
createdTs1717770983000
version0
createdDateNone
modifiedDateNone
blockNumberOffice of the Executive Engineer, P.R.E.Divisioin, Beside District Court Complex, Arab Mohalla, RAICHUR
streetNone
cityRaichur
stateKarnataka
pin584101
tenderRecallDTONone