3129693 | 107490 | None | AEEBDM001 | CONSTRUCTION OF ONE ROOM IN GOVERNMENT JUNIOR PRIMARY SCHOOL, JALAGERI LT1 OF BADAMI TALUK Earth work excavation by manual means for drains,canals, waste weir draft, approach channels, key trench, foundation of Bridges and such similar works, as per drawing and technical specifcations,including setting out, shoring, strutting, barricading, caution lights, excavated surface leveled and sides neatly dressed disposing off or leveling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work. (PWDSR 2021-22 Vol-1 P.No.6 I.No. 1.5.1) In ordinary/soft rock without blasting upto 1.5 m depth with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-charge | Cum | 195.3 | 195.3 | 58.24 | False | None | None | False | None | False | 11374.272 | 0 |
3129694 | 107490 | None | AEEBDM002 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:4:8 (M5) Using 40 mm nominal size graded crushed coarse aggregates PWD CSR 2021-22 Volume -1 Pg.No 15. I.No 2.1.2 with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-charge | Cum | 5466.3 | 5466.3 | 6.43 | False | None | None | False | None | False | 35148.309 | 0 |
3129695 | 107490 | None | AEEBDM003 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates PWD CSR 2021-22 Volume -1 Pg No 17. I.No 2.2.1.1with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-charge | Cum | 6240.15 | 6240.15 | 14.05 | False | None | None | False | None | False | 87674.1075 | 0 |
3129696 | 107490 | None | AEEBDM004 | For centering according to teh table for finished concrete (P no 7 vol II) with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-charge | Cum | 312.01 | 312.01 | 14.36 | False | None | None | False | None | False | 4480.4636 | 0 |
3129697 | 107490 | None | AEEBDM005 | Providing and laying in position Reinforced cement concrete for all Super structures of building, road work Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates PWD CSR 2021-22 Volume -1 P.No 17. I.No 2.5.1 with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-charge | Cum | 6491.1 | 6491.1 | 16.39 | False | None | None | False | None | False | 106389.129 | 0 |
3129698 | 107490 | None | AEEBDM006 | For centering according to the table for finished concrete (P no 7 vol II) = column with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-charge | Cum | 4543.77 | 4543.77 | 3.22 | False | None | None | False | None | False | 14630.9394 | 0 |
3129699 | 107490 | None | AEEBDM007 | For centering according to the table for finished concrete (P no 7 vol II) = plinth beam with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-charge | Cum | 3245.55 | 3245.55 | 1.24 | False | None | None | False | None | False | 4024.482 | 0 |
3129700 | 107490 | None | AEEBDM008 | For centering according to the table for finished concrete (P no 7 vol II) = beam and lintel with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-charge | Cum | 3894.66 | 3894.66 | 4.56 | False | None | None | False | None | False | 17759.6496 | 0 |
3129701 | 107490 | None | AEEBDM009 | For centering according to the table for finished concrete (P no 7 vol II) = slab with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-charge | Cum | 3245.55 | 3245.55 | 7.21 | False | None | None | False | None | False | 23400.4155 | 0 |
3129702 | 107490 | None | AEEBDM010 | For centering according to the table for finished concrete (P no 7 vol II) = chajja with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-charge | Cum | 2921.0 | 2921.0 | 0.16 | False | None | None | False | None | False | 467.36 | 0 |
3129703 | 107490 | None | AEEBDM011 | Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately). (PWD CSR 2021-22 / VOLUME 3 / P. NO 71 / I NO 11.32) with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-charge | Kg | 96.6 | 96.6 | 2563.9 | False | None | None | False | None | False | 247672.74 | 0 |
3129704 | 107490 | None | AEEBDM012 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.. PWD CSR 2021-22 Volume 2 P.No-14 I.No-6.8 with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-charge | Cum | 7030.8 | 7030.8 | 13.8 | False | None | None | False | None | False | 97025.04 | 0 |
3129705 | 107490 | None | AEEBDM013 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:4 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.. PWD CSR 2021-22 Volume 2 P.No-14 I.No-6.7 with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-charge | Cum | 7295.4 | 7295.4 | 14.4 | False | None | None | False | None | False | 105053.76 | 0 |
3129706 | 107490 | None | AEEBDM014 | Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work.( PWD SR Page No 7 Item No 1.8) with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-charge | Cum | 422.1 | 422.1 | 52.14 | False | None | None | False | None | False | 22008.294 | 0 |
3129707 | 107490 | None | AEEBDM015 | Providing and laying cement concrete pavement with 1:2:4 for commercial and residential building floor hard paths foot paths using 1 cemnet: 2 coarse sand: 4 graded stone agreegate 20mm nominal size including finishing complete as per engineer incharge.( PWD SR Page No 7 Item No 1.8) with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-charge | Cum | 6510.0 | 6510.0 | 9.77 | False | None | None | False | None | False | 63602.7 | 0 |
3129708 | 107490 | None | AEEBDM016 | Flooring with 25mm thick polished tandur blue stone slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab, , including cost of materials, labour, curing, polishing complete as per specifications.(PWD CSR 2021-22 Vol -2 P.No-64 / I.No-9.34 ) with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-charge | Sqm | 1251.6 | 1251.6 | 59.79 | False | None | None | False | None | False | 74833.164 | 0 |
3129709 | 107490 | None | AEEBDM017 | Providing 20 mm cement plaster of mix :1:6 (1 cement: 6 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.PWD CSR 2021-22 Volume -2 P.No-41 I.No-8.1.2 with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-charge | Sqm | 289.8 | 289.8 | 240.68 | False | None | None | False | None | False | 69749.064 | 0 |
3129710 | 107490 | None | AEEBDM018 | Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. PWD CSR 2021-22 Volume -2 P.No- 41 I.No-8.3.2 with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-charge | Sqm | 207.9 | 207.9 | 50.56 | False | None | None | False | None | False | 10511.424 | 0 |
3129711 | 107490 | None | AEEBDM019 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge PWD CSR 2021-22 Volume -2 P.No-50 I.No-8.51 with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-charge | Sqm | 87.15 | 87.15 | 118.8 | False | None | None | False | None | False | 10353.42 | 0 |
3129712 | 107490 | None | AEEBDM020 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. PWD CSR 2021-22 Volume 2 P.No-45 / I.No-8.25 with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-charge | Sqm | 110.25 | 110.25 | 126.72 | False | None | None | False | None | False | 13970.88 | 0 |
3129713 | 107490 | None | AEEBDM021 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. PWD CSR 2021-22 Vol -2 P.No-46 I.No-8.30 with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-charge | Sqm | 142.8 | 142.8 | 135.2 | False | None | None | False | None | False | 19306.56 | 0 |
3129714 | 107490 | None | AEEBDM022 | Providing lath plaster with cement mortor 1:3 5cm thick with 6mm dia mild steel bars at 20 cm c/c both horizantally and verticaly fixed with chiken mesh for drop chajja facia backing to cup board including cost of all materials labour providing and removing form work hom curing complete as per specifications with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-charge | Sqm | 1262.1 | 1262.1 | 5.04 | False | None | None | False | None | False | 6360.984 | 0 |
3129715 | 107490 | None | AEEBDM023 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding PWD CSR 2021-22 Volume -2 P.No-85 I.No-11.34A with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-charge | Kg | 164.85 | 164.85 | 113.4 | False | None | None | False | None | False | 18693.99 | 0 |
3129716 | 107490 | None | AEEBDM024 | Providing honne wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications. PWD CSR 2021-22 Volume 2 P.No-100 I.No-12.10 with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-charge | Cum | 94912.65 | 94912.65 | 0.25 | False | None | None | False | None | False | 23728.1625 | 0 |
3129717 | 107490 | None | AEEBDM025 | Providing and fixing in position fully panelled Honne wood shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. ( excluding cost of fixtures ) PWD CSR 2021-22 Volume -2 P.No-100 I.No-12.15 with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-charge | Sqm | 5109.3 | 5109.3 | 2.07 | False | None | None | False | None | False | 10576.251 | 0 |
3129718 | 107490 | None | AEEBDM026 | Providing and fixing in position Honnewood fully panelled shutters for windows with stiles and rails of 35mm. thick, 75mm wide in two halves with panels of 25mm thick including cost of materials, labour charges, usage charges complete as per specifications. (excluding cost of fixtures) PWD CSR 2021-22 Volume -2 P.No-101 I.No-12.23 with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-charge | Sqm | 5441.1 | 5441.1 | 3.98 | False | None | None | False | None | False | 21655.578 | 0 |
3129719 | 107490 | None | AEEBDM027 | Providing and fixing fixtures for door providing and fixing ISI marked M.S. Pressed butt hinges bright finished with necessary screws etc.12.68.1 125*65*2.12mm with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-charge | Each | 39.9 | 39.9 | 24.0 | False | None | None | False | None | False | 957.6 | 0 |
3129720 | 107490 | None | AEEBDM028 | Providing and fixing expansion hold fasteners on C.C/R.C.C/Brick masnory surface backing including drilling necessary holes and the cost of bolt etc complete 10.6.3 wedge expansion type fastener with threaded dia 12mm. with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-charge | Each | 31.5 | 31.5 | 20.0 | False | None | None | False | None | False | 630.0 | 0 |
3129721 | 107490 | None | AEEBDM029 | Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc . Complete. with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-charge | Each | 183.75 | 183.75 | 11.0 | False | None | None | False | None | False | 2021.25 | 0 |
3129722 | 107490 | None | AEEBDM030 | Providing and fixing aluminium tower bolts , ISI marked , andoised (anodic coating not less than grade AC 10 as per IS :1868 ) transperent or dyed to required colour or shade with necessary screws etc . Complete. with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-charge | Each | 116.55 | 116.55 | 20.0 | False | None | None | False | None | False | 2331.0 | 0 |
3129723 | 107490 | None | AEEBDM031 | Providing and fixing bright finished brass hanging type floor door stopper with necessary screws , etc. Complete with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-charge | Each | 114.45 | 114.45 | 2.0 | False | None | None | False | None | False | 228.9 | 0 |
3129724 | 107490 | None | AEEBDM032 | Providing and fixing chromium plated brass night latch of approved quality including necessary screws etc . Complete. with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-charge | Sqm | 652.05 | 652.05 | 2.0 | False | None | None | False | None | False | 1304.1 | 0 |
3129725 | 107490 | None | AEEBDM033 | Providing and fixing on wall face unplasticized rigid PVC rain water pipes confirming IS:13592 Type A , including jointing with seal ring confirming IS : 5382 , leaving 10mm gap for thermal expansion 1)single socketed pipes 75mm diameters. with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-charge | Mtr | 185.85 | 185.85 | 12.0 | False | None | None | False | None | False | 2230.2 | 0 |
3129726 | 107490 | None | AEEBDM034 | Proving and fixing hand rail of approved size by welding etc to steel ladder railing , balcony railing , staircase railing and similar works , including applying. with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-charge | Kg | 116.55 | 116.55 | 94.05 | False | None | None | False | None | False | 10961.5275 | 0 |
3129727 | 107490 | None | AEEBDM035 | providing wall black boards in CM 1:3 with two coats of black paint including finishing etc , complete. with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-charge | Sqm | 810.6 | 810.6 | 2.7 | False | None | None | False | None | False | 2188.62 | 0 |
3129728 | 107490 | None | AEEBDM036 | ELECTRIFICATION Supplying and wiring adopting loop system in existing PVC conduit / casing caping using 1100v grade , copper conductor fexibelemultistand FRLS PVC insulated , 2*1.5 Sqmm cable confirming to GTP , with a 6AMPS flush type SP control switch shall be fixed on existing plastic sheet or gang box , the other end of the wires shall be terminated with sufficent loose length in a wood or PVC round block. complete for each outlet ---do--- a)Short point upto 3mtr from taping point to outlet via switch (PWD BGM SR Electrical Pg.No.5 It.No.2.1.1) with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-charge | Mtr | 210.0 | 210.0 | 5.0 | False | None | None | False | None | False | 1050.0 | 0 |
3129729 | 107490 | None | AEEBDM037 | Medium point 3mtr upto 6 mtr from tapping point to out let via switch(PWD BGM SR Electrical Pg.No.5 It.No.2.1.1) with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-charge | Mtr | 288.75 | 288.75 | 2.0 | False | None | None | False | None | False | 577.5 | 0 |
3129730 | 107490 | None | AEEBDM038 | Long point above 6mtr upto 10mtr from tapping point to out let via switch (PWD BGM SR electrical Pg.No.5 It.No.2.1.3) with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-charge | Mtr | 420.0 | 420.0 | 2.0 | False | None | None | False | None | False | 840.0 | 0 |
3129731 | 107490 | None | AEEBDM039 | Supplying 6A flush type socket and 6amps flush type SP switch either surface/flush mounting in a existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS1293 and IS 3654 6amps 3/5 Way PWD BGM SR electrical Pg.No.15 It.No.3.1.2) with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-charge | Nos | 138.6 | 138.6 | 4.0 | False | None | None | False | None | False | 554.4 | 0 |
3129732 | 107490 | None | AEEBDM040 | Supplying and flush mounting teak wooden box without front plank ,made of not less than 12mm thick wood , after due groove cutting , Finishing with necessary cement plastering complete.10'' x 7'' x 3'' (254 x 178 x 76 mm) (PWD BGM SR Electrical PgNo3 It No1.63) with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-charge | Nos | 91.35 | 91.35 | 2.0 | False | None | None | False | None | False | 182.7 | 0 |
3129733 | 107490 | None | AEEBDM041 | Supplying and fixing of PVC casing capping on the wall or ceiling using necessary materials likes bends junction box , elbows , screws at a interval of 300mm etc as required 25mm(PWD BGM SR Electrical PgNo3 It No 8.2 with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-charge | Mtr | 25.2 | 25.2 | 30.0 | False | None | None | False | None | False | 756.0 | 0 |
3129734 | 107490 | None | AEEBDM042 | Wiring for lighting , power circuit using one of FRLS PVC insulated 1100EV grade multi stand copper conduter single core wire in a open aor consealed system of wiring as per IS 694:1919 and confirming GPT of group B do 1.5sqmm(PWD BGM SR Electrical PgNo6 It No 6.2) with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-charge | Mtr | 16.7 | 16.7 | 50.0 | False | None | None | False | None | False | 835.0 | 0 |
3129735 | 107490 | None | AEEBDM043 | Supplying and fixing regular MCB distrubution boards on wall/woods/flush mounting using required clamp bolts nuts etc with proviosion for fixing of suitable type capacity MCB's single phase / 3 phase / sing door with poder coated painting made out of 14SWG MS enclouser do I ) single door 4way SP and N (PWD BGM SR Electrical PgNo28 It No 5.18.1) | Nos | 815.85 | 815.85 | 4.0 | False | None | None | False | None | False | 3263.4 | 0 |
3129736 | 107490 | None | AEEBDM044 | Supplying and fixing regular MCB distrubution boards on wall/woods/flush mounting using required clamp bolts nuts etc with proviosion for fixing of suitable type capacity MCB's single phase / 3 phase / sing door with poder coated painting made out of 14SWG encloaser 2 II double door (PWD BGM SR Electrical 14-15 PgNo47 It No 6.17.3) with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-charge | Nos | 1099.35 | 1099.35 | 1.0 | False | None | None | False | None | False | 1099.35 | 0 |
3129737 | 107490 | None | AEEBDM045 | Supplying patti type flourocent tube light fitting of 4' suitable for 28 watts florocent tube fitting made out of MS sheet and stove enamaled with HF electronic ballast locking type brass contact holders mounted on double fold type sheet base fully wired for use on230 volts AC supply including T5 lamp (PWD BGM SR Electrical PgNo 20 It No 4.6) with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-charge | Nos | 1008.0 | 1008.0 | 3.0 | False | None | None | False | None | False | 3024.0 | 0 |
3129738 | 107490 | None | AEEBDM046 | Fixing all types and all capcities florocent or falls ceilling or spot light or CFL fitting indoor on the wall or ceilling or rafters or girders using 23/0.0076 inch twin twisted PVC insulated wires required numbers of round blocks and clamps do on wall or ceilling or rafters or girdes (PWD BGM SR Electrical PgNo 79 It No 14.7.1) with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-charge | Nos | 115.5 | 115.5 | 3.0 | False | None | None | False | None | False | 346.5 | 0 |
3129739 | 107490 | None | AEEBDM047 | Fixing a ceilling/wall mounting fan of all capacities and all types of existing S hook with fan regulator tothe existing board togather with supplying and fixing 5amps ceilling rows neccesary length of 23/0.0076 inch PVC insulated twin twisted copper wire and wiring (PWD BGM SR Electrical PgNo 80 It No 14.8) with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-charge | Nos | 157.5 | 157.5 | 2.0 | False | None | None | False | None | False | 315.0 | 0 |
3129740 | 107490 | None | AEEBDM048 | Supplying capcitor type ceilling fan compltet with down rod blades shackles canopies etc for operation on 230 volts 50cycles single phase supply confirming to ISS374 - 1979 and with double ball bearing system do 56 inch sweep (1400mm) economy model (PWD BGM SR Electrical PgNo 46 It No 7.3.2) with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-charge | Nos | 2233.35 | 2233.35 | 2.0 | False | None | None | False | None | False | 4466.7 | 0 |
3129741 | 107490 | None | AEEBDM049 | Supping and fixing of modular switched steped electronic fan regulator on existing modular switch as per IS 3854 and IS 1293 group A (PWD BGM SR Electrical PgNo 16 It No 3.7.6) with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-charge | Nos | 565.95 | 565.95 | 2.0 | False | None | None | False | None | False | 1131.9 | 0 |
3129742 | 107490 | None | AEEBDM050 | Supping and fixing and wiring eath leackage miniature circuit breaker ElMCB 240V/250V up to 300A sensitivity on existing wood or pannel board (PWD BGM SR Electrical PgNo 47 It No 6.18.2) with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-charge | Nos | 2754.15 | 2754.15 | 1.0 | False | None | None | False | None | False | 2754.15 | 0 |
3129743 | 107490 | None | AEEBDM051 | Supping fixing and wiring earth electrode for grounding conduits IC cutouts and other equipements on the meter board using 40mm dia 2.90 thick GI pipe 2.5m long buried in a pit the pit should be filled with equal portion of salt and charcoal 150mm all around the pipe to complte depth the connection from the pipe to the conduit etc is to be established through GI wire of size as per ISI 7.3.3 of IS 732 using 12mm dia bolts nuts washers and check nuts etc the shall have 16 through wholes of 122mm dia (PWD BGM SR Electrical 19-20 PgNo 40 It No 6.1) with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-charge with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-charge | Nos | 3149.69 | 3149.69 | 1.0 | False | None | None | False | None | False | 3149.69 | 0 |