createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1710594654494
version4
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeONE_COVER
evaluationTypeTextOne Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee500.00
emd29191.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose28-06-2024 17:30:00
tenderQueryClose27-06-2024 17:30:00
technicalBidOpenNone
publishedDate14-06-2024 17:32:24
publishedByPostRDPR_EE_DIV_BGK
publishedByUserKPE18661 - MALLANAGOUDA R BIRADAR
bidValidityPeriod90
noOfCalls1
preBidMeetingDateNone
preBidMeetingYnFalse
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonEE PRED BAGALKOTE
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumber08354235042
mobileNumberNone
tenderSupplierListNone
tenderSchedule
createdTs1710594654536
version4
createdDateNone
modifiedDateNone
tenderNumberRDPR/2023-24/BD/WORK_INDENT4527
titleCONSTRUCTION OF ONE ROOM IN GOVERNMENT JUNIOR PRIMARY SCHOOL, MOHANPUR OF BADAMI TALUK
descriptionCONSTRUCTION OF ONE ROOM IN GOVERNMENT JUNIOR PRIMARY SCHOOL, MOHANPUR OF BADAMI TALUK
categoryWORKS
categoryTextWorks
ecv1167650.61
deptNameRural Development and Panchayat Raj Department
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnTrue
location796
locationNameRDPR Division Office Bagalakote
provisionalAmount1390000.0
groupOverheadTotal0.0
fileNumberAEE/BDM/PRESB/2022-23/BVSSD/MOHANAPUR
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17105946550000NoneNoneBuildingsCONSTRUCTION OF ONE ROOM IN GOVERNMENT JUNIOR PRIMARY SCHOOL, MOHANPUR OF BADAMI TALUK1167650.61
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3129744107491NoneAEEBDM001CONSTRUCTION OF ONE ROOM IN GOVERNMENT JUNIOR PRIMARY SCHOOL, MOHANPUR OF BADAMI TALUK Earth work excavation by manual means for drains,canals, waste weir draft, approach channels, key trench, foundation of Bridges and such similar works, as per drawing and technical specifcations,including setting out, shoring, strutting, barricading, caution lights, excavated surface leveled and sides neatly dressed disposing off or leveling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work. (PWDSR 2021-22 Vol-1 P.No.6 I.No. 1.5.1) In ordinary/soft rock without blasting upto 1.5 m depth with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-chargeCum195.3195.358.24FalseNoneNoneFalseNoneFalse11374.2720
3129745107491NoneAEEBDM002Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:4:8 (M5) Using 40 mm nominal size graded crushed coarse aggregates PWD CSR 2021-22 Volume -1 Pg.No 15. I.No 2.1.2 with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-chargeCum5466.35466.36.43FalseNoneNoneFalseNoneFalse35148.3090
3129746107491NoneAEEBDM003Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates PWD CSR 2021-22 Volume -1 Pg No 17. I.No 2.2.1.1with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-chargeCum6240.156240.1514.05FalseNoneNoneFalseNoneFalse87674.10750
3129747107491NoneAEEBDM004For centering according to teh table for finished concrete (P no 7 vol II) with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-chargeCum312.01312.0114.36FalseNoneNoneFalseNoneFalse4480.46360
3129748107491NoneAEEBDM005Providing and laying in position Reinforced cement concrete for all Super structures of building, road work Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates PWD CSR 2021-22 Volume -1 P.No 17. I.No 2.5.1 with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-chargeCum6491.16491.116.39FalseNoneNoneFalseNoneFalse106389.1290
3129749107491NoneAEEBDM006For centering according to the table for finished concrete (P no 7 vol II) = column with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-chargeCum4543.774543.773.22FalseNoneNoneFalseNoneFalse14630.93940
3129750107491NoneAEEBDM007For centering according to the table for finished concrete (P no 7 vol II) = plinth beam with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-chargeCum3245.553245.551.24FalseNoneNoneFalseNoneFalse4024.4820
3129751107491NoneAEEBDM008For centering according to the table for finished concrete (P no 7 vol II) = beam and lintel with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-chargeCum3894.663894.664.56FalseNoneNoneFalseNoneFalse17759.64960
3129752107491NoneAEEBDM009For centering according to the table for finished concrete (P no 7 vol II) = slab with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-chargeCum3245.553245.557.21FalseNoneNoneFalseNoneFalse23400.41550
3129753107491NoneAEEBDM010For centering according to the table for finished concrete (P no 7 vol II) = chajja with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-chargeCum2921.02921.00.16FalseNoneNoneFalseNoneFalse467.360
3129754107491NoneAEEBDM011Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately). (PWD CSR 2021-22 / VOLUME 3 / P. NO 71 / I NO 11.32) with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-chargeKg96.696.62563.9FalseNoneNoneFalseNoneFalse247672.740
3129755107491NoneAEEBDM012Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.. PWD CSR 2021-22 Volume 2 P.No-14 I.No-6.8 with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-chargeCum7030.87030.813.8FalseNoneNoneFalseNoneFalse97025.040
3129756107491NoneAEEBDM013Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:4 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.. PWD CSR 2021-22 Volume 2 P.No-14 I.No-6.7 with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-chargeCum7295.47295.414.4FalseNoneNoneFalseNoneFalse105053.760
3129757107491NoneAEEBDM014Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work.( PWD SR Page No 7 Item No 1.8) with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-chargeCum422.1422.152.14FalseNoneNoneFalseNoneFalse22008.2940
3129758107491NoneAEEBDM015Providing and laying cement concrete pavement with 1:2:4 for commercial and residential building floor hard paths foot paths using 1 cemnet: 2 coarse sand: 4 graded stone agreegate 20mm nominal size including finishing complete as per engineer incharge.( PWD SR Page No 7 Item No 1.8) with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-chargeCum6510.06510.09.77FalseNoneNoneFalseNoneFalse63602.70
3129759107491NoneAEEBDM016Flooring with 25mm thick polished tandur blue stone slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab, , including cost of materials, labour, curing, polishing complete as per specifications.(PWD CSR 2021-22 Vol -2 P.No-64 / I.No-9.34 ) with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-chargeSqm1251.61251.659.79FalseNoneNoneFalseNoneFalse74833.1640
3129760107491NoneAEEBDM017Providing 20 mm cement plaster of mix :1:6 (1 cement: 6 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.PWD CSR 2021-22 Volume -2 P.No-41 I.No-8.1.2 with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-chargeSqm289.8289.8240.68FalseNoneNoneFalseNoneFalse69749.0640
3129761107491NoneAEEBDM018Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. PWD CSR 2021-22 Volume -2 P.No- 41 I.No-8.3.2 with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-chargeSqm207.9207.950.56FalseNoneNoneFalseNoneFalse10511.4240
3129762107491NoneAEEBDM019Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge PWD CSR 2021-22 Volume -2 P.No-50 I.No-8.51 with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-chargeSqm87.1587.15118.8FalseNoneNoneFalseNoneFalse10353.420
3129763107491NoneAEEBDM020Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. PWD CSR 2021-22 Volume 2 P.No-45 / I.No-8.25 with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-chargeSqm110.25110.25126.72FalseNoneNoneFalseNoneFalse13970.880
3129764107491NoneAEEBDM021Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. PWD CSR 2021-22 Vol -2 P.No-46 I.No-8.30 with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-chargeSqm142.8142.8135.2FalseNoneNoneFalseNoneFalse19306.560
3129765107491NoneAEEBDM022Providing lath plaster with cement mortor 1:3 5cm thick with 6mm dia mild steel bars at 20 cm c/c both horizantally and verticaly fixed with chiken mesh for drop chajja facia backing to cup board including cost of all materials labour providing and removing form work hom curing complete as per specifications with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-chargeSqm1262.11262.15.04FalseNoneNoneFalseNoneFalse6360.9840
3129766107491NoneAEEBDM023Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding PWD CSR 2021-22 Volume -2 P.No-85 I.No-11.34A with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-chargeKg164.85164.85113.4FalseNoneNoneFalseNoneFalse18693.990
3129767107491NoneAEEBDM024Providing honne wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications. PWD CSR 2021-22 Volume 2 P.No-100 I.No-12.10 with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-chargeCum94912.6594912.650.25FalseNoneNoneFalseNoneFalse23728.16250
3129768107491NoneAEEBDM025Providing and fixing in position fully panelled Honne wood shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. ( excluding cost of fixtures ) PWD CSR 2021-22 Volume -2 P.No-100 I.No-12.15 with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-chargeSqm5109.35109.32.07FalseNoneNoneFalseNoneFalse10576.2510
3129769107491NoneAEEBDM026Providing and fixing in position Honnewood fully panelled shutters for windows with stiles and rails of 35mm. thick, 75mm wide in two halves with panels of 25mm thick including cost of materials, labour charges, usage charges complete as per specifications. (excluding cost of fixtures) PWD CSR 2021-22 Volume -2 P.No-101 I.No-12.23 with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-chargeSqm5441.15441.13.98FalseNoneNoneFalseNoneFalse21655.5780
3129770107491NoneAEEBDM027Providing and fixing fixtures for door providing and fixing ISI marked M.S. Pressed butt hinges bright finished with necessary screws etc.12.68.1 125*65*2.12mm with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-chargeEach39.939.924.0FalseNoneNoneFalseNoneFalse957.60
3129771107491NoneAEEBDM028Providing and fixing expansion hold fasteners on C.C/R.C.C/Brick masnory surface backing including drilling necessary holes and the cost of bolt etc complete 10.6.3 wedge expansion type fastener with threaded dia 12mm. with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-chargeEach31.531.520.0FalseNoneNoneFalseNoneFalse630.00
3129772107491NoneAEEBDM029Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc . Complete. with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-chargeEach183.75183.7511.0FalseNoneNoneFalseNoneFalse2021.250
3129773107491NoneAEEBDM030Providing and fixing aluminium tower bolts , ISI marked , andoised (anodic coating not less than grade AC 10 as per IS :1868 ) transperent or dyed to required colour or shade with necessary screws etc . Complete. with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-chargeEach116.55116.5520.0FalseNoneNoneFalseNoneFalse2331.00
3129774107491NoneAEEBDM031Providing and fixing bright finished brass hanging type floor door stopper with necessary screws , etc. Complete with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-chargeEach114.45114.452.0FalseNoneNoneFalseNoneFalse228.90
3129775107491NoneAEEBDM032Providing and fixing chromium plated brass night latch of approved quality including necessary screws etc . Complete. with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-chargeEach652.05652.052.0FalseNoneNoneFalseNoneFalse1304.10
3129776107491NoneAEEBDM033Providing and fixing on wall face unplasticized rigid PVC rain water pipes confirming IS:13592 Type A , including jointing with seal ring confirming IS : 5382 , leaving 10mm gap for thermal expansion 1)single socketed pipes 75mm diameters. with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-chargeMtr185.85185.8512.0FalseNoneNoneFalseNoneFalse2230.20
3129777107491NoneAEEBDM034Proving and fixing hand rail of approved size by welding etc to steel ladder railing , balcony railing , staircase railing and similar works , including applying. with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-chargeKg116.55116.5594.05FalseNoneNoneFalseNoneFalse10961.52750
3129778107491NoneAEEBDM035providing wall black boards in CM 1:3 with two coats of black paint including finishing etc , complete. with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-chargeSqm810.6810.62.7FalseNoneNoneFalseNoneFalse2188.620
3129779107491NoneAEEBDM036ELECTRIFICATION Supplying and wiring adopting loop system in existing PVC conduit / casing caping using 1100v grade , copper conductor fexibelemultistand FRLS PVC insulated , 2*1.5 Sqmm cable confirming to GTP , with a 6AMPS flush type SP control switch shall be fixed on existing plastic sheet or gang box , the other end of the wires shall be terminated with sufficent loose length in a wood or PVC round block. complete for each outlet ---do--- a)Short point upto 3mtr from taping point to outlet via switch (PWD BGM SR Electrical Pg.No.5 It.No.2.1.1) with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-chargeMtr210.0210.05.0FalseNoneNoneFalseNoneFalse1050.00
3129780107491NoneAEEBDM037Medium point 3mtr upto 6 mtr from tapping point to out let via switch(PWD BGM SR Electrical Pg.No.5 It.No.2.1.1) with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-chargeMtr288.75288.752.0FalseNoneNoneFalseNoneFalse577.50
3129781107491NoneAEEBDM038Long point above 6mtr upto 10mtr from tapping point to out let via switch (PWD BGM SR electrical Pg.No.5 It.No.2.1.3) with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-chargeMtr420.0420.02.0FalseNoneNoneFalseNoneFalse840.00
3129782107491NoneAEEBDM039Supplying 6A flush type socket and 6amps flush type SP switch either surface/flush mounting in a existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS1293 and IS 3654 6amps 3/5 Way PWD BGM SR electrical Pg.No.15 It.No.3.1.2) with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-chargeNos138.6138.64.0FalseNoneNoneFalseNoneFalse554.40
3129783107491NoneAEEBDM040Supplying and flush mounting teak wooden box without front plank ,made of not less than 12mm thick wood , after due groove cutting , Finishing with necessary cement plastering complete.10'' x 7'' x 3'' (254 x 178 x 76 mm) (PWD BGM SR Electrical PgNo3 It No1.63) with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-chargeNos91.3591.352.0FalseNoneNoneFalseNoneFalse182.70
3129784107491NoneAEEBDM041Supplying and fixing of PVC casing capping on the wall or ceiling using necessary materials likes bends junction box , elbows , screws at a interval of 300mm etc as required 25mm(PWD BGM SR Electrical PgNo3 It No 8.2 with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-chargeMtr25.225.230.0FalseNoneNoneFalseNoneFalse756.00
3129785107491NoneAEEBDM042Wiring for lighting , power circuit using one of FRLS PVC insulated 1100EV grade multi stand copper conduter single core wire in a open aor consealed system of wiring as per IS 694:1919 and confirming GPT of group B do 1.5sqmm(PWD BGM SR Electrical PgNo6 It No 6.2) with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-chargeMtr16.716.750.0FalseNoneNoneFalseNoneFalse835.00
3129786107491NoneAEEBDM043Supplying and fixing regular MCB distrubution boards on wall/woods/flush mounting using required clamp bolts nuts etc with proviosion for fixing of suitable type capacity MCB's single phase / 3 phase / sing door with poder coated painting made out of 14SWG MS enclouser do I ) single door 4way SP and N (PWD BGM SR Electrical PgNo28 It No 5.18.1)Nos815.85815.854.0FalseNoneNoneFalseNoneFalse3263.40
3129787107491NoneAEEBDM044Supplying and fixing regular MCB distrubution boards on wall/woods/flush mounting using required clamp bolts nuts etc with proviosion for fixing of suitable type capacity MCB's single phase / 3 phase / sing door with poder coated painting made out of 14SWG encloaser 2 II double door (PWD BGM SR Electrical 14-15 PgNo47 It No 6.17.3) with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-chargeNos1099.351099.351.0FalseNoneNoneFalseNoneFalse1099.350
3129788107491NoneAEEBDM045Supplying patti type flourocent tube light fitting of 4' suitable for 28 watts florocent tube fitting made out of MS sheet and stove enamaled with HF electronic ballast locking type brass contact holders mounted on double fold type sheet base fully wired for use on230 volts AC supply including T5 lamp (PWD BGM SR Electrical PgNo 20 It No 4.6) with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-chargeNos1008.01008.03.0FalseNoneNoneFalseNoneFalse3024.00
3129789107491NoneAEEBDM046Fixing all types and all capcities florocent or falls ceilling or spot light or CFL fitting indoor on the wall or ceilling or rafters or girders using 23/0.0076 inch twin twisted PVC insulated wires required numbers of round blocks and clamps do on wall or ceilling or rafters or girdes (PWD BGM SR Electrical PgNo 79 It No 14.7.1) with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-chargeNos115.5115.53.0FalseNoneNoneFalseNoneFalse346.50
3129790107491NoneAEEBDM047Fixing a ceilling/wall mounting fan of all capacities and all types of existing S hook with fan regulator tothe existing board togather with supplying and fixing 5amps ceilling rows neccesary length of 23/0.0076 inch PVC insulated twin twisted copper wire and wiring (PWD BGM SR Electrical PgNo 80 It No 14.8) with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-chargeNos157.5157.52.0FalseNoneNoneFalseNoneFalse315.00
3129791107491NoneAEEBDM048Supplying capcitor type ceilling fan compltet with down rod blades shackles canopies etc for operation on 230 volts 50cycles single phase supply confirming to ISS374 - 1979 and with double ball bearing system do 56 inch sweep (1400mm) economy model (PWD BGM SR Electrical PgNo 46 It No 7.3.2) with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-chargeNos2233.352233.352.0FalseNoneNoneFalseNoneFalse4466.70
3129792107491NoneAEEBDM049Supping and fixing of modular switched steped electronic fan regulator on existing modular switch as per IS 3854 and IS 1293 group A (PWD BGM SR Electrical PgNo 16 It No 3.7.6) with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-chargeNos565.95565.952.0FalseNoneNoneFalseNoneFalse1131.90
3129793107491NoneAEEBDM050Supping and fixing and wiring eath leackage miniature circuit breaker ElMCB 240V/250V up to 300A sensitivity on existing wood or pannel board (PWD BGM SR Electrical PgNo 47 It No 6.18.2) with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-chargeNos2754.152754.151.0FalseNoneNoneFalseNoneFalse2754.150
3129794107491NoneAEEBDM051Supping fixing and wiring earth electrode for grounding conduits IC cutouts and other equipements on the meter board using 40mm dia 2.90 thick GI pipe 2.5m long buried in a pit the pit should be filled with equal portion of salt and charcoal 150mm all around the pipe to complte depth the connection from the pipe to the conduit etc is to be established through GI wire of size as per ISI 7.3.3 of IS 732 using 12mm dia bolts nuts washers and check nuts etc the shall have 16 through wholes of 122mm dia (PWD BGM SR Electrical 19-20 PgNo 40 It No 6.1) with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-charge with all lead and lifts loading & unloading etc. complete as per direction of Engineer-in-chargeNos3149.693149.691.0FalseNoneNoneFalseNoneFalse3149.690
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17105946550000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17105946550000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17105946550000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17105946550000NoneNoneELIGIBILITYDepartment Registration DetailsNone
17105946550000NoneNoneELIGIBILITYTotal value of civl engineering works executed and payments received in the last five years (year-wise)None
17105946550000NoneNoneELIGIBILITYList of existing commitments and ongoing workNone
17105946550000NoneNoneELIGIBILITYList of works for which tenders already submittedNone
17105946550000NoneNoneELIGIBILITYBanker DetailsNone
17183630760000NoneNoneELIGIBILITYThe Tenderer shall obtain the workdone certificate in the prescribed format from the Competent Authority not below the rank of Executive Engineer(District Level Officer)and scan the Original Certificate and attach the scanned file to the Bid.None
17183630850000NoneNoneELIGIBILITYAll the documents to be uploaded shall be neatly scanned and the documents scanned shall be in original.None
17183630880000NoneNoneELIGIBILITYThe bidder is required to ensure browser compatibility of the computer well in advance to the last date and time for receipt of tenders The departments shall not be responsible for non accessibility of KPPP portal due to internet connectivity issues and technical glitches at bidders endNone
17183630920000NoneNoneELIGIBILITYAll materials required for the work shall be procured by the tenderer himself and should be got tested by the quality control authorities at his own cost before use on work.None
17183630950000NoneNoneELIGIBILITYAcceptence / Cancellation of the works are reserved by under signed without any reasons for the same.None
17183630990000NoneNoneELIGIBILITYIf any date in the tender time table is government holiday, next working date will be consideredNone
17183631030000NoneNoneELIGIBILITYIncomplete / conditional tenders will not be accepted.None
17183631060000NoneNoneELIGIBILITYTenderer must submit his present accurate postal address and phone / cell phone numberNone
17183631100000NoneNoneELIGIBILITYThe cost of the Tender form shall not be refundable.None
17183631130000NoneNoneELIGIBILITYUnique Document Identification Number (UDIN) from Practicing Chartered Account Must PreferredNone
17183631200000NoneNoneELIGIBILITYWork shall be executed as per KTPP Act & KW-1&2 Conditions.None
17183631230000NoneNoneELIGIBILITYThe Rates Quoted In The Estimates Are Exclusive of GST Taxes.None
17183631270000NoneNoneELIGIBILITYThe GST will be Paid Separately to the Contractors as per the Guidelines of the Government Time to Time.None
17183631300000NoneNoneELIGIBILITYSuccessful bidder submitting bids below the amount put to tender will be regularized to submit the difference amount in the form of FDR/TDR/DD/Pledge on the name of EE PRED Bagalkote within 20 days from the date of receiving the letter of acceptance. additional security paid for unbalanced tenders Failing which EMD will be forfeited and further action will be taken as per G O No FD PCL 2008 Bangalore Dated 14/10/2008.None
17183631370000NoneNoneELIGIBILITYAs per Government order No. FD 56 PWD cell 2004, Bngalore, 18th Janury 2005, The contractor shall be made responsible for submiting e-bills duly suported the hard copy of detailed measurements of work. using electrinic spreadsheets and making computation thereof. The conctractor shall submit diskette/ CD room in addition the hard copy.None
17183631440000NoneNoneELIGIBILITYThe tenderers must submit the scanned documents in pdf / jpeg form, not in other form and which are should not be corrupted files. If it shows errors while opening the documents the employer is not responsible. Hence the such files will be considerd as un submitted.None
17183631500000NoneNoneELIGIBILITYTo qualify for award of this contract, each Tenderer in its name should have in the last five years i.e., 2019-20, 2020-21, 2021-22 2022-23 & 2023-24 Achieved in at least two financial years a minimum financial turnover in all classes of civil engineering construction works only of Amount Put Tender (Turn over With compulsory UDIN Number) (in all classes of civil engineering construction works only)None
17183631590000NoneNoneELIGIBILITYThe Tenderer shall obtain similar the workdone certificate Construction of Building Works within the financial years of 2019-20 to 2023-24 (50% of the Amount Put to Tender) i.e in the prescribed format from the Competent Authority not below the rank of Executive Engineer(District Level Officer) and scan the Original Certificate and attach the scanned file to the Bid.None
17183631630000NoneNoneELIGIBILITYTenderer must have liquid assets and /or availability of credit facilities of not less than 30% amount Put to Tender (Credit lines/ letter of credit/ certificates from banks for meeting the fund requirement etc. for three months of (LOC letter should be unconditional format)None
17183631680000NoneNoneELIGIBILITYThis work is Randomized as OTHERS Category. Hence any Category of Contractor can bid.None
17183631720000NoneNoneELIGIBILITYTenderers must have valid PRED/PWD registration CLASS-2 AND ABOVE and must submit PRED/PWD registration copy.None
17183631770000NoneNoneELIGIBILITYSingle Tender Will Not Be AcceptedNone
17183631860000NoneNoneELIGIBILITYNOTE : ONLY RELEVANT SCANNED COPY OF THE ORIGINAL DOCUMENT TO BE ATTACHED FOR THE CORRESPONDING CONDITIONS MENTIONED.None
17183631900000NoneNoneELIGIBILITYPeriod for completion of work is 7 MonthsNone
17183631930000NoneNoneELIGIBILITYThe Project Completion period is 7 Months and the defect liability period of the work is (2) TWO year after successful completion of the work. (including Monsoon).None
17183631970000NoneNoneELIGIBILITYTenderer must submit copies of documents according to KW-1&2 documentNone
17183632010000NoneNoneELIGIBILITYLot No: 383/2022-23 Sl No 05 OthersNone
preQualCriterionListNone
technicalCriterionListNone
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
PRED/PWD CLASS-II AND ABOVE Registration CertificateTrueTechnical Bid
Tenderer must Submit PAN & GST CertificateTrueTechnical Bid
Tenderer must have of value 2019-20 to 2023-24 satisfactorily completed as a prime contractor at least one Similar nature of work of 50PERCENT of the Amount Put to Tender Percent of not less than Rs.5.88 lakhs issued by the officer not below the rank of Executive Engineer For Similer nature /Building works work done certificate with works shoud be produced Workdone with indent NoTrueTechnical Bid
Work orders / commitments of ongoing works issued by an officer not below the rank of Executive EngineerTrueTechnical Bid
Tenderer must have liquid assets and /or availability of credit facilities of not less than 30PERCENT amount Put to Tender Credit lines/ letter of credit/ certificates from banks for meeting the fund requirement etc. for three months of Rs.3.50 Lakhs LOC letter should be unconditional formatTrueTechnical Bid
Annual Turnover Certificate for at least last five yearsTrueTechnical Bid
To qualify for award of this contact each tenderer in his name should have in the 2019-20 to 2023-24 years period achieved in at least two financial years an average financial turnover of Rs.11.68 Lakhs usually not less than amount put to tender from C.A. on Letter Head with UDIN No. otherwise bid will be directly disqualifiedTrueTechnical Bid
Accurate postal address and phone / cell phone numberTrueTechnical Bid
Tenderers who meet the above specified minimum qualifying criteria, will only be qualified, if their available tender capacity is more than the total tender value. The available tender capacity will be calculated as under Assessed available tender capacity A X N X 2.5 - BTrueTechnical Bid
Contractor Should submit the difference amount as per the CSR 2024-25 & it is to be handed over to the EEPRE Divison Office, Bagalkot after Issuing the LOI.TrueTechnical Bid
tenderWorkLocationList
tenderSubEstimateNamedistrictNametaluqNameloksabhaContNameassemblyContNamelocationDescriptionlatitudeDegreeslatitudeMinuteslatitudeSecondslongitudeDegreeslongitudeMinuteslongitudeSeconds
BuildingsBagalkoteBadamiBagalkotBADAMICONSTRUCTION OF ONE ROOM IN GOVERNMENT JUNIOR PRIMARY SCHOOL, MOHANPUR OF BADAMI TALUKNoneNoneNoneNoneNoneNone
tenderAddressNone
tenderRecallDTONone