createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1718349701826
version2
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee2390.00
emd191000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose29-06-2024 17:00:00
tenderQueryClose20-06-2024 12:00:00
technicalBidOpen01-07-2024 17:00:00
publishedDate14-06-2024 14:19:39
publishedByPostKSSIDC_SE_HOD_BNG
publishedByUserKPE14915 - K GURU
bidValidityPeriod90
noOfCalls1
preBidMeetingDate21-06-2024 12:00:00
preBidMeetingYnTrue
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonGuru K
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedNone
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumberNone
mobileNumber9448323311
tenderSupplierListNone
tenderSchedule
createdTs1718349701856
version5
createdDateNone
modifiedDateNone
tenderNumberKSSIDC/2024-25/WT/WORK_INDENT14
titleConstruction of 95 KLD Sewage Treatment Plant at Industrial Estate Doddaballapura, Bengaluru Rural District.
descriptionConstruction of 95 KLD Sewage Treatment Plant at Industrial Estate Doddaballapura Bengaluru Rural Dist
categoryWORKS
categoryTextWorks
ecv9537565.73
deptNameKarnataka State Small Industries Development Corporation Limited
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnTrue
location2622
locationNameKSSIDC Head Office Bengaluru
provisionalAmount11300000.0
groupOverheadTotalNone
fileNumberNo-ENGG-SE-ep-84-DPR-Halisagar-Shahapura-STP-D-pura-2024-25
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17183497020001NoneNoneWater /sewage treatment tanksConstruction of 95 KLD Sewage Treatment Plant at Industrial Estate Doddaballapura, Bengaluru Rural District.9537565.73
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3288207114279Nonecode01Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work.Cum115.46115.46122.0FalseNoneNoneFalseNoneFalse14086.120
3288208114279Nonecode02Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. In all kinds of soils Depth upto 3.0 mCum123.97123.97638.0FalseNoneNoneFalseNoneFalse79092.860
3288209114279Nonecode03Cost of De-watering upto 5 percentage of A+B may be added, where required assessment for dewatering shall be made as per site conditionCum6.26.2638.0FalseNoneNoneFalseNoneFalse3955.60
3288210114279Nonecode04Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. In all kinds of soils In ordinary/soft rock without blasting, Depth exceeding 3m, but not exceeding 4.5mCum562.73562.73166.0FalseNoneNoneFalseNoneFalse93413.180
3288211114279Nonecode05Cost of De-watering upto 10percentage of A+B may be added, where required assessment for dewatering shall be made as per site conditionCum56.2756.27166.0FalseNoneNoneFalseNoneFalse9340.820
3288212114279Nonecode06Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. In all kinds of soils In ordinary/soft rock without blasting,Depth not exceeding 4.5mCum590.87590.8790.0FalseNoneNoneFalseNoneFalse53178.30
3288213114279Nonecode07Cost of De-watering upto 10 percentage of A+B may be added, where required assessment for dewatering shall be made as per site conditionCum56.2756.2790.0FalseNoneNoneFalseNoneFalse5064.30
3288214114279Nonecode08Earth work excavation for Foundation by Mechanical means depth upto 1.50m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including cost of explosives, dressing of excavated surfaces, disposing off or levelling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5m including cost of labour, blasting materials, tools, usage of Machinery & all other appurtenaces required tocomplete the work. In all kinds of soils In In Hard Rock requiring blasting Depth not exceeding 4.5mCum864.15864.1510.0FalseNoneNoneFalseNoneFalse8641.50
3288215114279Nonecode09Cost of De-watering upto 10 percentage of A+B may be added, where required assessment for dewatering shall be made as per site conditionCum86.4186.4110.0FalseNoneNoneFalseNoneFalse864.10
3288216114279Nonecode10Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver/grader in sub-base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density.Cum3110.213110.2120.0FalseNoneNoneFalseNoneFalse62204.20
3288217114279Nonecode11Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8 M5 Using 40 mm nominal size graded crushed coarse aggregatesCum6884.036884.0320.0FalseNoneNoneFalseNoneFalse137680.60
3288218114279Nonecode12Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications Mix 1:3:6 M10 Using 20 mm nominal size graded crushed coarse aggregatesCum7556.147556.149.0FalseNoneNoneFalseNoneFalse68005.260
3288219114279Nonecode13Providing and laying in position Cement Concrete for all Foundation works.The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates including form work for RaftCum8023.288023.2861.0FalseNoneNoneFalseNoneFalse489420.080
3288220114279Nonecode14Providing and laying in position Cement Concrete for all Foundation works.The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for Raft Base, Screed ConcreteCum7641.227641.2214.0FalseNoneNoneFalseNoneFalse106977.080
3288221114279Nonecode15Providing and laying in position Cement Concrete for all Foundation works.The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates including form work for Retaining wallCum8405.348405.3485.0FalseNoneNoneFalseNoneFalse714453.90
3288222114279Nonecode16Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. for Roof slab, M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates including form workCum11527.4611527.4620.0FalseNoneNoneFalseNoneFalse230549.20
3288223114279Nonecode17Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, for Lintles and Beams Including form workCum12892.9612892.968.0FalseNoneNoneFalseNoneFalse103143.680
3288224114279Nonecode18Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, For COLUMNS Including form WorkCum13698.7713698.772.9FalseNoneNoneFalseNoneFalse39726.4330
3288225114279Nonecode19Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, Roof Slab Including form workCum12087.1512087.1517.0FalseNoneNoneFalseNoneFalse205481.550
3288226114279Nonecode20Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specificationTonne108726.04108726.0417.51FalseNoneNoneFalseNoneFalse1903792.96040
3288227114279Nonecode21Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 Part - I - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.Sqm1592.171592.1782.0FalseNoneNoneFalseNoneFalse130557.940
3288228114279Nonecode22Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 1 cement: 4 fine sand including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm358.54358.54750.0FalseNoneNoneFalseNoneFalse268905.00
3288229114279Nonecode23Providing 12 mm cement plaster with cement mortar 1:4 1 cement: 4 fine sand to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm309.93309.93268.0FalseNoneNoneFalseNoneFalse83061.240
3288230114279Nonecode24Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by weldingKgs204.19204.19121.0FalseNoneNoneFalseNoneFalse24706.990
3288231114279Nonecode25Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in- Charge.Kgs165.29165.29225.0FalseNoneNoneFalseNoneFalse37190.250
3288232114279Nonecode26Supplying and fixing Rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. including Lock of Brand Electroprime: Electroprime office verticle cross rolling shutter Door lock Roller latch with keys.Sqm4428.094428.095.0FalseNoneNoneFalseNoneFalse22140.450
3288233114279Nonecode27Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm139.77139.7726.0FalseNoneNoneFalseNoneFalse3634.020
3288234114279Nonecode28Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work Two coats applied @ 1.43 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm216.34216.34413.0FalseNoneNoneFalseNoneFalse89348.420
3288235114279Nonecode29Providing, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete Contractor will make his own arrangements for procuring water for testing etc. complete. NOTE: Upto 110mm dia Coil shall be used. For :HDPE PE 80 PN 6.0 90mm diam390.14390.14800.0FalseNoneNoneFalseNoneFalse312112.00
3288236114279Nonecode30Supply and delivery at site of brand new best make non-return valve as per IS 778/1984 with ISI Mark and as per its latest amendments. Size 80 mmEach2126.952126.954.0FalseNoneNoneFalseNoneFalse8507.80
3288237114279Nonecode31Providing and installation of Class SN8 Double Wall Corrugated HDPE Specials outer wall corrugated and inner wall smooth piping system in accordance with IS 16098 part 2 and conveying to work site and lowering into trenches, laying true to line and level and perfect linking at joints with the help of two O rings and a coupler of suitable size, including loading and unloading at both destination and cutting of pipes where ever necessary including jointing with all labour, all lead and lift including encasing the Specials around to a depth of not less than 15cm with screened soft soil available from the excavated soil. The testing commissioning including necessary hydraulic test to the required pressure as per ISS shall be done the contractor shall have to make his own arrangement for procuring water for testing etc. complete.90 MM ELECTRO FUSION COUPLEREach280.76280.7620.0FalseNoneNoneFalseNoneFalse5615.20
3288238114279Nonecode32Providing and installation of Class SN8 Double Wall Corrugated HDPE Specials outer wall corrugated and inner wall smooth piping system in accordance with IS 16098 part 2 and conveying to work site and lowering into trenches, laying true to line and level and perfect linking at joints with the help of two O rings and a coupler of suitable size, including loading and unloading at both destination and cutting of pipes where ever necessary including jointing with all labour, all lead and lift including encasing the Specials around to a depth of not less than 15cm with screened soft soil available from the excavated soil. The testing commissioning including necessary hydraulic test to the required pressure as per ISS shall be done the contractor shall have to make his own arrangement for procuring water for testing etc. complete.90 MM ELECTRO FUSION TEEEach641.73641.7320.0FalseNoneNoneFalseNoneFalse12834.60
3288239114279Nonecode33Providing and installation of Class SN8 Double Wall Corrugated HDPE Specials outer wall corrugated and inner wall smooth piping system in accordance with IS 16098 part 2 and conveying to work site and lowering into trenches, laying true to line and level and perfect linking at joints with the help of two O rings and a coupler of suitable size, including loading and unloading at both destination and cutting of pipes where ever necessary including jointing with all labour, all lead and lift including encasing the Specials around to a depth of not less than 15cm with screened soft soil available from the excavated soil. The testing commissioning including necessary hydraulic test to the required pressure as per ISS shall be done the contractor shall have to make his own arrangement for procuring water for testing etc. complete. 90 MM ELECTRO FUSION ELBOWEach550.58550.5820.0FalseNoneNoneFalseNoneFalse11011.60
3288240114279Nonecode34Providing and installation of Class SN8 Double Wall Corrugated HDPE Specials outer wall corrugated and inner wall smooth piping system in accordance with IS 16098 part 2 and conveying to work site and lowering into trenches, laying true to line and level and perfect linking at joints with the help of two O rings and a coupler of suitable size, including loading and unloading at both destination and cutting of pipes where ever necessary including jointing with all labour, all lead and lift including encasing the Specials around to a depth of not less than 15cm with screened soft soil available from the excavated soil. The testing commissioning including necessary hydraulic test to the required pressure as per ISS shall be done the contractor shall have to make his own arrangement for procuring water for testing etc. complete. 90 MM ELECTRO FUSION COUPLEREach280.76280.7615.0FalseNoneNoneFalseNoneFalse4211.40
3288241114279Nonecode35Providing and installation of Class SN8 Double Wall Corrugated HDPE Specials outer wall corrugated and inner wall smooth piping system in accordance with IS 16098 part 2 and conveying to work site and lowering into trenches, laying true to line and level and perfect linking at joints with the help of two O rings and a coupler of suitable size, including loading and unloading at both destination and cutting of pipes where ever necessary including jointing with all labour, all lead and lift including encasing the Specials around to a depth of not less than 15cm with screened soft soil available from the excavated soil. The testing commissioning including necessary hydraulic test to the required pressure as per ISS shall be done the contractor shall have to make his own arrangement for procuring water for testing etc. complete. 90 MM x 63 MM ELECTRO FUSION REDUCEREach537.21537.2115.0FalseNoneNoneFalseNoneFalse8058.150
3288242114279Nonecode36Supply and delivery at site of brand new HDPE Specials as per techincal specificationsetc ,completeas per the direction of Engineer incharge of work. All D.I. Flanged Socketed 100.00 mmEach1302.911302.9120.0FalseNoneNoneFalseNoneFalse26058.20
3288243114279Nonecode37Supply and delivery at site special moulded variety PVC service saddles as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments.90 mm dia PVC SERVICE SADDLESEach256.45256.4565.0FalseNoneNoneFalseNoneFalse16669.250
3288244114279Nonecode38Providing and fixing Chlorinated Polyvinyl Chloride CPVC pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work. 20 MM Diam263.74263.7450.0FalseNoneNoneFalseNoneFalse13187.00
3288245114279Nonecode39Supplying, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete Contractor will make his own arrangements for procuring water for testing etc. Note: Upto 110mm dia Coil shall be used. For Grade PE80 PN6.0 : HDPE Grade PE80-PN10.0,225mm dia mm3296.163296.1680.0FalseNoneNoneFalseNoneFalse263692.80
3288246114279Nonecode40Providing and installation of Class SN8 Double Wall Corrugated HDPE Specials outer wall corrugated and inner wall smooth piping system in accordance with IS 16098 part 2 and conveying to work site and lowering into trenches, laying true to line and level and perfect linking at joints with the help of two O rings and a coupler of suitable size, including loading and unloading at both destination and cutting of pipes where ever necessary including jointing with all labour, all lead and lift including encasing the Specials around to a depth of not less than 15 cm with screened soft soil available from the excavated soil. The testing commissioning including necessary hydraulic test to the required pressure as per ISS shall be done the contractor shall have to make his own arrangement for procuring water for testing etc. complete. 250 ID BEND - DWC HDPE 250mm dia PipesEach1186.231186.234.0FalseNoneNoneFalseNoneFalse4744.920
3288247114279Nonecode41Providing and installation of Class SN8 Double Wall Corrugated HDPE Specials outer wall corrugated and inner wall smooth piping system in accordance with IS 16098 part 2 and conveying to work site and lowering into trenches, laying true to line and level and perfect linking at joints with the help of two O rings and a coupler of suitable size, including loading and unloading at both destination and cutting of pipes where ever necessary including jointing with all labour, all lead and lift including encasing the Specials around to a depth of not less than 15 cm with screened soft soil available from the excavated soil. The testing commissioning including necessary hydraulic test to the required pressure as per ISS shall be done the contractor shall have to make his own arrangement for procuring water for testing etc. complete. 250 ID Coupler - DWC HDPE 250mm dia PipesEach666.04666.044.0FalseNoneNoneFalseNoneFalse2664.160
3288248114279Nonecode42Providing and installation of Class SN8 Double Wall Corrugated HDPE Specials outer wall corrugated and inner wall smooth piping system in accordance with IS 16098 part 2 and conveying to work site and lowering into trenches, laying true to line and level and perfect linking at joints with the help of two O rings and a coupler of suitable size, including loading and unloading at both destination and cutting of pipes where ever necessary including jointing with all labour, all lead and lift including encasing the Specials around to a depth of not less than 15 cm with screened soft soil available from the excavated soil. The testing commissioning including necessary hydraulic test to the required pressure as per ISS shall be done the contractor shall have to make his own arrangement for procuring water for testing etc. complete. 250 ID TEE - DWC HDPE 250mm dia PipesEach2156.122156.122.0FalseNoneNoneFalseNoneFalse4312.240
3288249114279Nonecode43Providing and installation of Class SN8 Double Wall Corrugated HDPE Specials outer wall corrugated and inner wall smooth piping system in accordance with IS 16098 part 2 and conveying to work site and lowering into trenches, laying true to line and level and perfect linking at joints with the help of two O rings and a coupler of suitable size, including loading and unloading at both destination and cutting of pipes where ever necessary including jointing with all labour, all lead and lift including encasing the Specials around to a depth of not less than 15cm with screened soft soil available from the excavated soil. The testing commissioning including necessary hydraulic test to the required pressure as per ISS shall be done the contractor shall have to make his own arrangement for procuring water for testing etc. complete. 90 MM x 63 MM ELECTRO FUSION REDUCEREach537.21537.2115.0FalseNoneNoneFalseNoneFalse8058.150
3288250114279Nonecode44Supply and delivery at site of brand new HDPE Specials as per techincal specificationsetc ,completeas per the direction of Engineer incharge of work. All D.I. Flanged Socketed 100.00 mmEach1302.911302.9120.0FalseNoneNoneFalseNoneFalse26058.20
3288251114279Nonecode45Providing and fixing MS ladder between landings, 45 cms wide using angle iron of specified sizes, 20mm MS bars at 25 cms. centre to centre, with necessary supports of same angle iron etc. as directed, including hand railing on both sides with 25mm dia. GI pipes with angle iron props at 2 mtrs. intervals and 0.5M heigh, including fixing in ground with CC 1:2:4 and two coats of anticorrosive bituminous paint etc. with all lead and lifts etc. complete with: MS angle of 65 x 65 x 10mmm5835.145835.148.0FalseNoneNoneFalseNoneFalse46681.120
3288252114279Nonecode46Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm inner dimensions with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and coverEach6628.796628.791.0FalseNoneNoneFalseNoneFalse6628.790
3288253114279Nonecode47Making bore in Machinehole without damaging the existing Machinehole, fixing the pipe of any diameter in line and level with CC 1:2:4, plastering the outer and inner surface in CM 1:3 including curing etc. The cost includes the cost of materials, labour charges, lead and lifts etc. complete as per specifications and as directed by the EngineerEach256.45256.4525.0FalseNoneNoneFalseNoneFalse6411.250
3288254114279Nonecode48Fencing with G.I. barbed wire R.C.C. post placed at required distance, embedded in cement concrete blocks, every 15th post, last but one end post and corner post shall be strutted on both sides and end post one side only, provided with horizontal lines and two diagonals of barbed wire weighing 9.38 kg per 100 m minimum , between the two posts fitted and fixed with G.I. staples on wooden plugs or G.I. binding wire tied to 6 mm bar nibs fixed while casting the post cost of R.C.C. posts, struts, earth work and concrete to be paid for separately ,Payment to be made per metre cost of total length of barbed wire used. With G.I. barbed wireRmtr14.5814.581308.0FalseNoneNoneFalseNoneFalse19070.640
3288255114279Nonecode49Erection of 1x63KVA, 11KV/433V DTC as per cost Data sheet-60 9 mtr PSCC DP Transformer Structure BESCOM SR 2023-24Set32648.2432648.241.0FalseNoneNoneFalseNoneFalse32648.240
3288256114279Nonecode5011 kV, 5 KN Polymeric Pin Insulator 24 mm Dia FRP Rod BESCOM SR 2023-24Nos241.9241.93.0FalseNoneNoneFalseNoneFalse725.70
3288257114279Nonecode5111 kV, 45 KN Polymeric InsulatorBESCOM SR 2023-24Nos219.48219.483.0FalseNoneNoneFalseNoneFalse658.440
3288258114279Nonecode52Guy Set Complete with No. 15 Strain Insulator & Concreting materialsBESCOM SR 2023-24Set1380.61380.64.0FalseNoneNoneFalseNoneFalse5522.40
3288259114279Nonecode531kV/433V, 63 kVA, 3 Phase, 50 Cys Distribution Transformer BEE - 5 Star Rated with OilBESCOM SR 2023-24No215403.1215403.11.0FalseNoneNoneFalseNoneFalse215403.10
3288260114279Nonecode54Earthing materials pipe type for grounding Single Electrode with accessories BESCOM SR 2023-24Set2040.222040.225.0FalseNoneNoneFalseNoneFalse10201.10
3288261114279Nonecode55Caution/Danger BoardBESCOM SR 2023-24No177.0177.01.0FalseNoneNoneFalseNoneFalse177.00
3288262114279Nonecode56Anti Climbing Device 12 Mtr GI Barbed Wire BESCOM SR 2023-24No105.02105.022.0FalseNoneNoneFalseNoneFalse210.040
3288263114279Nonecode57GI Wire 8 SWGBESCOM SR 2023-24Kg88.5588.555.0FalseNoneNoneFalseNoneFalse442.750
3288264114279Nonecode58Guy wire 7/10 SWG BESCOM SR 2023-24Kg91.1391.1310.0FalseNoneNoneFalseNoneFalse911.30
3288265114279NoneCode59811 kV Lightning Arrester, Metal Oxide 9 kV, 5 kA, Polymetic type with ground disconnector BESCOM SR 2023-24Set of 3 Nos5607.365607.361.0FalseNoneNoneFalseNoneFalse5607.360
3288266114279Nonecode60a LT Protection Kit for 63 kVA BESCOM SR 2023-24No2387.142387.142.0FalseNoneNoneFalseNoneFalse4774.280
3288267114279Nonecode61b LT Wiring From DTC to LT Line Through Metering Box & LT Protection Kit SINGLE Al Lead Wire - 95 Sqmm BESCOM SR 2023-24Mtr131.32131.3240.0FalseNoneNoneFalseNoneFalse5252.80
3288268114279Nonecode62ii Heavy Duty Long Barrel Copper Lug - 95 SqmmBESCOM SR 2023-24No152.22152.224.0FalseNoneNoneFalseNoneFalse608.880
3288269114279Nonecode63PG Clamp - Rabbit to 95 SqmmBESCOM SR 2023-24Nos165.2165.24.0FalseNoneNoneFalseNoneFalse660.80
3288270114279Nonecode64Spacer for DTC WiringBESCOM SR 2023-24Nos49.5649.568.0FalseNoneNoneFalseNoneFalse396.480
3288271114279Nonecode65Fish Plate with necessary Clamps, bolts & nuts etc complete Galvanised BESCOM SR 2023-24Nos311.52311.522.0FalseNoneNoneFalseNoneFalse623.040
3288272114279Nonecode66LT Metering box with CTs and necessary wiring for housing ETV Meter Please see CDS-39 BESCOM SR 2023-24No6636.326636.321.0FalseNoneNoneFalseNoneFalse6636.320
3288273114279Nonecode67LT Electronic Tri-Vector Meter 5 Amps, -0.5/1.0 Accuracy ClassBESCOM SR 2023-24No4007.284007.281.0FalseNoneNoneFalseNoneFalse4007.280
3288274114279Nonecode6811 kV, Solid Core Type HG Fuse UnitBESCOM SR 2023-24Set1261.421261.421.0FalseNoneNoneFalseNoneFalse1261.420
3288275114279Nonecode6911 kV, 200 Amps, Single Break GOSBESCOM SR 2023-24No.11151.011151.01.0FalseNoneNoneFalseNoneFalse11151.00
3288276114279Nonecode70Providing chain link fencing 50 mm size of 8 guage properly stretched between rectangular Poles and fixed with suitable bolts & nuts, the free ends shall be welded to the Pole and block pipe at top and bottom as required including cost of all materials, labour, lead and lifts, cutting, bending wherever necessary, wastage and lapping etc., complete as per the direction of the engineer incharge for work including two coats of approved quality paint over one coat of primer paint.BESCOM SR 2021-22WRDO SRSqm1164.661164.6640.0FalseNoneNoneFalseNoneFalse46586.40
3288277114279Nonecode71Transparent Alkathine tube 19 mm dia, 2 mm thick in coils of 30 MtBESCOM SR 2023-24, Cost data sheet -31Coil610.06610.061.0FalseNoneNoneFalseNoneFalse610.060
3288278114279Nonecode7211 kV, Horizontal Cross Arm with clamps, HTST supports, bolts, nuts and washers for RCC Pole - 9 Mtr Long, 145 Kg WBESCOM SR 2023-24No1003.01003.03.0FalseNoneNoneFalseNoneFalse3009.00
3288279114279Nonecode7311 kV, 5 KN Polymeric Pin Insulator 24 mm Dia FRP RodBESCOM SR 2023-24No241.9241.96.0FalseNoneNoneFalseNoneFalse1451.40
3288280114279Nonecode7411 kV, 45 KN Polymeric InsulatorBESCOM SR 2023-24No219.48219.486.0FalseNoneNoneFalseNoneFalse1316.880
3288281114279Nonecode75Rabbit ACSR ConductoBESCOM SR 2023-24Km54556.1254556.120.1FalseNoneNoneFalseNoneFalse5455.6120
3288282114279Nonecode761.1 kV-XLPE or Heat resistant PVC insulated- PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 Part-1 or IS-7098 Part-1-Armouring strip thickness and resistivity as per IS-3975 95 Sqmm-3.5 Core- 21 GI Strips - 4 X 0.8 mmKm440393.7440393.70.12FalseNoneNoneFalseNoneFalse52847.2440
3288283114279Nonecode77Pre-Insulated Lug-CPTAU for 95 SqmmNo451.94451.9416.0FalseNoneNoneFalseNoneFalse7231.040
3288284114279Nonecode78LT 3 Phase, 4 Wire, CT Operated DLMS Complaint ETV Meter-5A, class 0.5s Accuracy Used for 25 HP/18KW & Above Installations, DTC Metering BESCOM SR2021-22No3908.163908.161.0FalseNoneNoneFalseNoneFalse3908.160
3288285114279Nonecode79Meter Protection/Tamper Proof box with busbar for LT 3 Ph with CT Ratio 50/5A, 1.0 Accuracy Class BESCOM SR2021-22No7264.087264.081.0FalseNoneNoneFalseNoneFalse7264.080
3288286114279Nonecode80LT AC 3 Phase 4 Wire CT Operated, 5 Amps Smart Energy Meter, Class 0.5s Accuracy with GPRS Communication ModuleBESCOM SR2021-22No4720.04720.01.0FalseNoneNoneFalseNoneFalse4720.00
3288287114279Nonecode81GI Grounding pipe, B - Class, 42 mm dia, 2.5 Mtr long, 3.2 mm thick with bolt, nut, GI Strips and washer complete Minimum Weight of GI Pipe: 7.3 Kg BESCOM SR2021-22No908.6908.61.0FalseNoneNoneFalseNoneFalse908.60
3288288114279Nonecode82Good Quality well burnt Charcoal for grounding purposes packed in non returnable gunny bag of 30 Kg each BESCOM SR2021-22No778.8778.81.0FalseNoneNoneFalseNoneFalse778.80
3288289114279Nonecode83Labour Charges Erection of a 9 mtr RCC DP Transformer Structure BESCOM SR 2021-22Set6141.96141.91.0FalseNoneNoneFalseNoneFalse6141.90
3288290114279Nonecode84Digging of pit for 9 mtr RCC pole hard soil BESCOM SR 2021-22No1932.841932.842.0FalseNoneNoneFalseNoneFalse3865.680
3288291114279Nonecode85Erection of Guy set BESCOM SR 2021-22Set528.64528.644.0FalseNoneNoneFalseNoneFalse2114.560
3288292114279Nonecode86Erection of 11 kV/433 V 3 phase 50 Cys 63 kVA Distribution Transformer BEE -5 Star Rated with oilBESCOM SR 2021-22No1018.341018.341.0FalseNoneNoneFalseNoneFalse1018.340
3288293114279Nonecode87Earthing materials pipe type for grounding Single Electrode with accessories BESCOM SR 2021-22Set855.5855.55.0FalseNoneNoneFalseNoneFalse4277.50
3288294114279Nonecode88Erection of Caution / Danger Board as per Drawing No. BESCOM/GM/CP/40/Dt: 24.10.07BESCOM SR 2021-22No71.9871.981.0FalseNoneNoneFalseNoneFalse71.980
3288295114279Nonecode89Anti Climbing Device 12 Mtr GI Barbed WireKg37.7637.762.0FalseNoneNoneFalseNoneFalse75.520
3288296114279Nonecode9011 kV Lightning Arrester-Metal Oxide 9 kV- 5 kA- Polymetic type with ground disconnector3 Set106.2106.21.0FalseNoneNoneFalseNoneFalse106.20
3288297114279Nonecode91LT Protection Kit for 63 kVABESCOM SR 2021-22No306.8306.82.0FalseNoneNoneFalseNoneFalse613.60
3288298114279Nonecode92Erection/Fixing of LT Wiring From DTC to LT Line Through Metering Box & LT Protection Kit SINGLE Al Lead Wire - 95 Sqmm Heavy Duty Long Barrel Copper Lug - 95 Sqmm PG Clamp - Rabbit to 95 SqmmSpacer for DTC WiringFish Plate with necessary Clamps, bolts & nuts etc complete GalvanisedSet848.42848.421.0FalseNoneNoneFalseNoneFalse848.420
3288299114279Nonecode93Erection of LT Metering box with CTs and necessary wiring for housing ETV Meter Please see CDS - 39 BESCOM SR 2021-22No767.0767.01.0FalseNoneNoneFalseNoneFalse767.00
3288300114279Nonecode94LT Electronic Tri-Vector Meter 5 Amps, -0.5/1.0 Accuracy ClasBESCOM SR 2021-22No941.64941.641.0FalseNoneNoneFalseNoneFalse941.640
3288301114279Nonecode9511 kV, Solid Core Type HG Fuse UnitBESCOM SR 2021-22Set210.04210.041.0FalseNoneNoneFalseNoneFalse210.040
3288302114279Nonecode96Erection of GOS 200 A single breakBESCOM SR 2021-22No949.9949.91.0FalseNoneNoneFalseNoneFalse949.90
3288303114279Nonecode97Concreting for Guy sets without cementNo236.0236.04.0FalseNoneNoneFalseNoneFalse944.00
3288304114279Nonecode98Labour charges for fixing Meter Protection/Tamper Proof box with busbar for LT 3 Ph with CT Ratio 50/5A, 1.0 Accuracy Class BESCOM SR2021-22No767.0767.01.0FalseNoneNoneFalseNoneFalse767.00
3288305114279Nonecode99Labour charges for fixing of LT AC 3 Phase 4 Wire CT Operated, 5 Amps Smart Energy Meter, BESCOM SR2021-22No938.1938.11.0FalseNoneNoneFalseNoneFalse938.10
3288306114279Nonecode100Labour charges for earthing BESCOM SR 2021-22No855.5855.51.0FalseNoneNoneFalseNoneFalse855.50
3288307114279Nonecode101Stringing of ACSR Rabbit conductorBESCOM SR 2021-22Km3892.823892.820.1FalseNoneNoneFalseNoneFalse389.2820
3288308114279Nonecode102Fabricating supplying and mounting MS box made out SWG suitable for floor-wall mounting-fully weather proof with provision for better heat dissipation-provided with hinged front cover-equipped with tamper proof locking arrangements-with suitable size clA with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc-complete-16 SWG PWD SR 2021-22Sq CM0.450.4530000.0FalseNoneNoneFalseNoneFalse13500.00
3288309114279Nonecode103Supplying and fixing angle iron frame work fabricated out of M.S. angle iron and M.S. Flat with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint 50 x 50 x 6 mmPWD SR 2021-22Mtr420.08420.0810.0FalseNoneNoneFalseNoneFalse4200.80
3288310114279Nonecode104Supplying . A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete 100 A 4 x 30 x 6 mm Aluminium StripsMtr2612.522612.520.5FalseNoneNoneFalseNoneFalse1306.260
3288311114279Nonecode105Supplying and fixing Moulded Case Circuit Breaker MCCB over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. Icu equal 100percentage lcs.In 4P MCCB-all Poles should have protection for Short-Cicrcuit-Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open . Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.FOUR Pole 100 A 25 kA PWD SR 2021-22No9752.79752.71.0FalseNoneNoneFalseNoneFalse9752.70
3288312114279Nonecode106Earth work excavation for cable trench of 0.5 to 0.75 Mtr. Width and Depth upto 1 Mtr including trial pits, depositing on bank upto a lead of 50 Mtr, Supplying and Displaying necessary Danger Boards and Lighting, Using sight Rails and Sign Boards at every 100 Mtr wherever necessary as directed.In Hard Soil9 BESCOM SR2021-22Cum459.02459.0218.75FalseNoneNoneFalseNoneFalse8606.6250
3288313114279Nonecode107Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staf LT cable 35 to 95 Sqmm BESCOM SR2021-22Km27903.4627903.460.12FalseNoneNoneFalseNoneFalse3348.41520
3288314114279Nonecode108Supplying and fixing angle iron frame work fabricated out of M.S. angle iron and M.S. Flat with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint.40 x 40 x 6 mm PWD SR 2021-22Mtr324.5324.510.0FalseNoneNoneFalseNoneFalse3245.00
3288315114279Nonecode109Supplying of TPST with rewirable porcelain channels in SM enclosure. Made out of 14 SWG powder coated paint of approved colour.63A PWD SR 2021-22No4434.444434.441.0FalseNoneNoneFalseNoneFalse4434.440
3288316114279Nonecode110Supplying heavy gauge PVC conduit pipe dia mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws 19/20 mm dia 2 mm thick PWD SR 2021-22Mtr80.2480.2415.0FalseNoneNoneFalseNoneFalse1203.60
3288317114279Nonecode111Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 Phase & Neutral & 1x1.0 mm 2 Earth wire FRLS multi strand PVC insulated copper wire confirming to IS-694: and latest amendments with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet Medium point above 3m upto 6m from tapping point to out let via switch PWD SR 2021-22Point455.48455.483.0FalseNoneNoneFalseNoneFalse1366.440
3288318114279Nonecode112Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.2.5 mm2 PWD SR 2021-22Mtr47.247.230.0FalseNoneNoneFalseNoneFalse1416.00
3288319114279Nonecode113Supplying 6A flush type socket and 6 A flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3654 6A 3/5 Way PWD SR 2021-22No168.74168.741.0FalseNoneNoneFalseNoneFalse168.740
3288320114279Nonecode114Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.6 WayPWD SR 2021-22No175.82175.821.0FalseNoneNoneFalseNoneFalse175.820
3288321114279Nonecode115Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.6-32 A DPPWD SR 2021-22No1301.541301.541.0FalseNoneNoneFalseNoneFalse1301.540
3288322114279Nonecode116Supply and fixing polished wood board made of not less than 15mm thick plank on both sides of not more than 2 pieces and fixing the same to the wall using tapered inverted wooden plugs screws.8 x 6 x 1.5 PWD SR 2021-22No89.6889.681.0FalseNoneNoneFalseNoneFalse89.680
3288323114279Nonecode117Supplying of feet -PVC Batten with integrated LED tube W with high quality diffuser with Life of 25000 burning hours and 70 percentage lumen maintenance with CRI greater than 80. Power Input: 220-240V at 50-60Hz and Power factor greater than 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition LED light fitting 1 x 4 - 20-22 WPWD SR 2021-22No873.2873.22.0FalseNoneNoneFalseNoneFalse1746.40
3288324114279Nonecode118Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material delivering superior light output Rated life Burning Hrs 50000 hr at Lumen Maintenance of 70percentage, maximum light intensity should be between 60 degrees to 70 degrees. CCT greater than 5500K, IP66 optical and electrical compartment & impact resistance of complete luminaire greater than IK08. Power Factor greater than 0.9 with mains Surge Protection Min 5KV along with Over voltage-Overload short circuit- miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm-Universal Voltage driver to operate wide voltage range from 100V to 270V 50-60Hz application. Compliance to IS 10322-IEC 60598 LM 79 and LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with W System Power consumption. LED Efficiency greater than 1301m-w, nominal CRI greater than 75. Luminaire manufacturer should have in-house facility accredited by NABL-CPRI and any Government certified agency and Design and Development facility certified by ISO 9001-2008. Housing with supplier word mark -name shall be Engraved- Embossing on the die cast housing-Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentionedLED Streetlight 40W PWD SR 2021-22No4308.184308.181.0FalseNoneNoneFalseNoneFalse4308.180
3288325114279Nonecode119Supplying and Fixing mm dia class A GI pipe bracket upto 2.7 meters long terminated with a reducing collar of 40x25mm to which extra pipe of 175mm length is fixed for fixing MV/SV/MH/FTL street light fitting of all capacities on rail/RCC/wall/tubular pole, using suitable clA, bolts, nuts and wiring using suitable capacity wires.Using 40mm dia G.I.Pipe PWD SR2021-22No1544.621544.621.0FalseNoneNoneFalseNoneFalse1544.620
3288326114279Nonecode120Fixing all types and all capacities of fluorescent -false ceiling - spot light - CFL - LED fittings indoor on the wall- ceiling - rafters - girders using 23-0.0076 twin twisted PVC insulated wires required Nos of round blocks and clA.On wall- ceiling - Rafter - Girders PWD SR 2021-22No140.42140.422.0FalseNoneNoneFalseNoneFalse280.840
3288327114279Nonecode121Digging of Pit for providing GI Pipe type Earthing Hard SoilBESCOM SR2021-22No2675.062675.061.0FalseNoneNoneFalseNoneFalse2675.060
3288328114279Nonecode122Bar Screen Fine and Coarse Made by MS bright flat 20mm x 6mm placed at 16mm c-c with clear opening 10mm wide. All SS parts shall be coated by epoxy premierNos54280.054280.02.0FalseNoneNoneFalseNoneFalse108560.00
3288329114279Nonecode123Coarse bubble Aeration: Diffused Air Grid with PVC pipe laterals and supports for Equalization Tank.Set219480.0219480.01.0FalseNoneNoneFalseNoneFalse219480.00
3288330114279Nonecode124Twin Lobe Air Blowers Capacity : 150 m3-hr Head : 4,500mm WG Make : Kay or equivalent Type : Twin Lobe CompressorNos184080.0184080.02.0FalseNoneNoneFalseNoneFalse368160.00
3288331114279Nonecode125Diffusers- Air diffuser membrane EPDM membrane with PVC pipe grid-1m Long in two rows.Lot232460.0232460.01.0FalseNoneNoneFalseNoneFalse232460.00
3288332114279Nonecode126Raw-Sewage-Sludge Return-Filter Feed pumps Capacity: 10-12 m3-hr at 10-15 m Head, Type : Centrifugal Self-priming pumps. The motor shall be 5HP 3 Phase KDI Model provided with weatherproof cover.Nos69030.069030.07.0FalseNoneNoneFalseNoneFalse483210.00
3288333114279Nonecode127Pressure Sand Filter Size : 0.9 m Dia Working pressure: 1.5 to 2kg-cm2, Test pressure : 4.0kg-cm2 Self supported on 3 legs with dished ends and 6mm thick MS shell with sand gravel and activated carbon media. MS face piping. Inside painted with bitumen and outside enamel paint over red oxide primer.Nos231280.0231280.01.0FalseNoneNoneFalseNoneFalse231280.00
3288334114279Nonecode128Activated Carbon Filter Size : 0.9 m Dia Working pressure: 1.5 to 2kg/cm2, Test pressure : 4.0kg/cm2 Self supported on 3 legs with dished ends & 6mm thick MS shell with sand, gravel & activated carbon media. MS face piping. Inside painted with bitumen & outside enamel paint over red oxide primer.Nos289100.0289100.01.0FalseNoneNoneFalseNoneFalse289100.00
3288335114279Nonecode129Filter Press with Screw Pump Type :Recessed Model :Series 600 Size :18 inch x 18 inch Make : Precision -Equivalent Material of Construction: Polypropylene Pressure Test : 5 kg- cm2 Pressure Operation : 3 kg-cm2Nos278480.0278480.01.0FalseNoneNoneFalseNoneFalse278480.00
3288336114279Nonecode130Chlorinator With chemical dosing pump for 4LPH capacity. 1 lot of PVC flexi tubes for suction and delivery of Sodium hypochlorite solution with 100ltr capacity solution tank etc complete.Nos171100.0171100.01.0FalseNoneNoneFalseNoneFalse171100.00
3288337114279Nonecode131Inter Unit Piping Inter Unit Piping in PVC/ HDPE pipes with valves and fittings etc., completeMtr915.1915.1490.0FalseNoneNoneFalseNoneFalse448399.00
3288338114279Nonecode132Electricals Providing MCC Panel with Starter cabling, earthing etc., complete to commission the Plant System integrating Pump Blowers etc including power wiring total inside plant room etc.Mtr770.61770.61490.0FalseNoneNoneFalseNoneFalse377598.90
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17183497050000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17183497050000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17183497050001NoneNoneELIGIBILITYAll terms and condition as per the Standard tender document dated 13-06-2024None
17183497050000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17183497050000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneMinimum financial turnover (civil engineering construction works) not less than two times the annual payments from this contract (Rs. xxxxx Lakhs)NoneNone
NoneNoneNoneNoneSatisfactoriy completed (atleast 90%) as prime contractor at-least one such similar work of value not less than Rs. xxxxxxx (80% of estimated cost of tender)NoneNone
NoneNoneNoneNoneExecuted in any one year the following minimum quantities of work (Cement Concrete - xxxx cum, Earthwork - xxxx cum, etc) (80% of peak rate of construction)NoneNone
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid Electrical License for executing building electrificatio works and should have executed similar electrical works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid license for executing water supply / sanitary engineering works and should have executed similar works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneOwning the following key and critical equipment for this work (xxxx, xxxx, xxxx)NoneNone
NoneNoneNoneNoneLiquid assets and /or availability of credit facilities of no less than Rs. xxxxxx Lakhs (estimated cash flow for 3 months of peak construction period)NoneNone
NoneNoneNoneNoneTotal value of civl engineering works executed and payments received in the last five years (year-wise)NoneNone
NoneNoneNoneNoneList of existing commitments and ongoing worksNoneNone
NoneNoneNoneNoneList of works for which tenders already submittedNoneNone
NoneNoneNoneNoneBanker Details for referenceNoneNone
NoneNoneNoneNoneConstruction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneReports on the financial standing of the tenderer, such as profit and loss statements and auditor’s reports for the last five yearsNoneNone
NoneNoneNoneNoneQualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneList of Financial Resources with CertificatesNoneNone
NoneNoneNoneNoneSatisfactorily completed, AT LEAST 50 percentage OF CONTRACT VALUE as prime contractor, at least one similar work such as Construction of STP-Allied works of value not less than Rs. 47.70 lakhs (Along with Work Indent Number) (Updated to 2023-24 Price level)Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneAchieved in at least two financial years a minimum financial turnover (in all classes of civil engineering construction works only) of Rs. 191.00 Lakhs (Along with UDIN Registration Number).Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNoneCREDIT FACILITES OF NOT LESS THAN 35percentage OF THE AMOUNT PUT TO TENDER (CREDIT LINES/ LETTERS OF CREDIT/ CERTIFICATES FROM BANKS (Rs.33.40 Lakhs)OthersLOC
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneLine of Credit
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Annual Turnover CertificateFalseTechnical Bid
Company Registration CertificateFalseTechnical Bid
PWD REGISTRATION CERTIFICATETrueTechnical Bid
GSTIN REGISTRATION CERTIFICATETrueTechnical Bid
PAN NUMBER OF BIDDERTrueTechnical Bid
WORK DONE CERTIFICATETrueTechnical Bid
SPECIFIC TURNOVER CERTIFICATE FROM CHARTERED ACCOUNTANT FOR RELEVANT YEARS, INDICATING YEAR WISE TURNOVER 2019-20, 2020-2021, 2021-22, 2022-23 & 2023-24TrueTechnical Bid
AUDITED PROFIT & LOSS ACCOUNT & BALANCE SHEET, INCOME TAX RETURN CERTIFICATEsTrueTechnical Bid
LIST OF MACHINERIESTrueTechnical Bid
AFFIDAVIT ON STAMP PAPER WORTH Rs. 500/-TrueTechnical Bid
CREDIT FACILITES OF NOT LESS THAN 35percentage OF THE AMOUNT PUT TO TENDER CREDIT LINES-LETTERS OF CREDIT-CERTIFICATES FROM BANKS Rs.33.40 LakhsTrueTechnical Bid
tenderWorkLocationList
tenderSubEstimateNamedistrictNametaluqNameloksabhaContNameassemblyContNamelocationDescriptionlatitudeDegreeslatitudeMinuteslatitudeSecondslongitudeDegreeslongitudeMinuteslongitudeSeconds
Water /sewage treatment tanksBengaluru RuralDoddaballapuraNoneNoneKSSIDC Industrial Estate DoddaballapuraNoneNoneNoneNoneNoneNone
tenderAddress
createdTs1718351205000
version0
createdDateNone
modifiedDateNone
blockNumberOffice of the Superintending Engineer, KSSIDC Ltd., Industrial Estate, Rajajinagar
streetNone
cityBengaluru
stateKarnataka
pin560010
tenderRecallDTONone