createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1718284084606
version7
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeONE_COVER
evaluationTypeTextOne Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee500.00
emd37500.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose21-06-2024 16:30:00
tenderQueryClose19-06-2024 16:30:00
technicalBidOpenNone
publishedDate13-06-2024 18:44:37
publishedByPostRDPR_EE_DIV_KWR
publishedByUserKPE11438 - GOVIND CHAPPER
bidValidityPeriod90
noOfCalls3
preBidMeetingDateNone
preBidMeetingYnFalse
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnTrue
percentageRateTypeTextNone
contactPersonEXECUTIVE ENGINEER
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumberNone
mobileNumber9632627434
tenderSupplierListNone
tenderSchedule
createdTs1718284084608
version20
createdDateNone
modifiedDateNone
tenderNumberRDPR/2023-24/BD/WORK_INDENT4463/CALL-3
titleConstruction of Kelaginmane Anganwadi Building at Kaikini GP in Bhatkal taluka Uttar Kannada District
descriptionConstruction of Kelaginmane Anganwadi Building at Kaikini GP in Bhatkal taluka Uttar Kannada District
categoryWORKS
categoryTextWorks
ecv1262999.35
deptNameRural Development and Panchayat Raj Department
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnTrue
location949
locationNameRDPR Division Office Karwar
provisionalAmount1500000.0
groupOverheadTotal0.0
fileNumberRDPR/2022-23/ICDSMGNREG/SCHOOL/KELAGINMANE/BHATKAL/03
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17182840850000NoneNoneBuildings2022 23 ICDS MGNREG Action plan Construction of Kelaginmane Anganwadi Building at Kaikini GP in Bhatkal taluka Uttar Kannada District1262999.35
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3286159114172NonePREE01Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In ordinary/soft rock without blasting upto 1.5 m depth (PWD CSR 2023-24 , Volume-I It No 1.15.1 Page No 8)Cum406.56406.5660.28FalseNoneNoneFalseNoneFalse24507.43680
3286160114172NonePREE02Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates (PWD CSR 2023-24, Volume-I It No 2.1.3 Page No 15)Cum6908.916908.916.79FalseNoneNoneFalseNoneFalse46911.49890
3286161114172NonePREE03Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (PWD CSR 2023-24, Volume-I It No 2.2.1 Page No 15)Cum7664.037664.0316.8899FalseNoneNoneFalseNoneFalse129444.7002970
3286162114172NonePREE04Providing and constructing laterite size stone masonry including cost and conveyance of all materials curing etc complete as per specification. I.S. 3620/1979 having compressive strength not less then 3.5 N/mm2 for saturated dry samples. For Foundation in CM 1:6 (PWD CSR 2023-24, Volume- It No 5.5 Page No 9 )Cum7138.887138.889.26FalseNoneNoneFalseNoneFalse66106.02880
3286163114172NonePREE05Providing and constructing laterite size stone masonry including cost and conveyance of all materials curing etc complete as per specification. I.S. 3620/1979 having compressive strength not less then 3.5 N/mm2 for saturated dry samples. For Basement in CM 1:6 (PWD CSR 2023-24, Volume- It No 5.6 Page No 9 )Cum7221.767221.769.94FalseNoneNoneFalseNoneFalse71784.29440
3286164114172NonePREE06Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (PWD CSR 2023-24, Volume-I It No 2.5.2 Page No 17)Cum13029.0713029.073.2199FalseNoneNoneFalseNoneFalse41952.3024930
3286165114172NonePREE07Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (PWD CSR 2023-24, Volume-I It No 2.5.2 Page No 17)Cum12262.6512262.652.65FalseNoneNoneFalseNoneFalse32496.02250
3286166114172NonePREE08Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (PWD CSR 2023-24, Volume-I It No 2.5.2 Page No 17)Cum12262.6612262.665.83FalseNoneNoneFalseNoneFalse71491.30780
3286167114172NonePREE09Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (PWD CSR 2023-24, Volume-I It No 2.5.2 Page No 17)Cum11496.2411496.2411.3FalseNoneNoneFalseNoneFalse129907.5120
3286168114172NonePREE10Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (PWD CSR 2023-24, Volume-I It No 2.5.2 Page No 17)Cum11113.0311113.031.47FalseNoneNoneFalseNoneFalse16336.15410
3286169114172NonePREE11Steel Fabrication Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.a. Buildings (PWD CSR 2023-24, Volume-I It No 2.11 a Page No 18)Kg100.19100.193502.85FalseNoneNoneFalseNoneFalse350950.54150
3286170114172NonePREE12Providing & fixing of 2-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having a overall size of 60mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm X 58mm with GI reinforcement of 1mm for the frame and 1.5 mm for the sash. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 2-2.5 mm. Maximum possible size 1819mm x 1819mm (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)(PWD CSR 2023-24, Volume-II It No 12.86 Page No 109)Sqm6036.86036.87.92FalseNoneNoneFalseNoneFalse47811.4560
3286171114172NonePREE13Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross- section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame (Page : 112, I. No. 12.96 ) 2023-24 PWD CSR Volume-2Mtr720.16720.1618.07FalseNoneNoneFalseNoneFalse13013.29120
3286172114172NonePREE14Providing and fixing to existing door frames Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames. 12.97.1 30 mm thickness(PWD CSR 2023-24, Volume-II It No 12.86 Page No 112)Sqm3588.483588.4811.33FalseNoneNoneFalseNoneFalse40657.47840
3286173114172NonePREE15Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (PWD CSR 2023-24 Volume-II It.No 11.5.1 Page 77)Sqm5015.365015.3610.08FalseNoneNoneFalseNoneFalse50554.82880
3286174114172NonePREE16Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops.and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.(PWD CSR 2023-24, Volume-II It No 8.29 Page No 45)Sqm316.96316.96305.0FalseNoneNoneFalseNoneFalse96672.80
3286175114172NonePREE17Electrification Supplying heavy gauge PVC conduit pipe ……mm dia .......mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary25mm dia 2mm thick( It. No 1.2.2 Electrical Sr 2023-24 Page. No 2)Mtr78.078.050.0FalseNoneNoneFalseNoneFalse3900.00
3286176114172NonePREE18Supplying and fixing PVC/metal conduit Deep junction box 25mm deep junction box( It. No 1.5.2 Electrical Sr 2023-24 Page. No 3)No56.056.08.0FalseNoneNoneFalseNoneFalse448.00
3286177114172NonePREE19Extra for Groove cutting in brick wall/CC floor to the suitable depth for concealing of Conduit/GI pipe and plastering, finishing upto wall surface complete.upto 50mm conduit in brick wall( It. No 1.7.2 Electrical Sr 2023-24 Page. No 3)Mtr69.069.040.0FalseNoneNoneFalseNoneFalse2760.00
3286178114172NonePREE20Supplying and fixing 32Amps security and energy saving DP switch with key tag suitable to operate on 230 Volts, 50Hz AC supply & completely wired on existing box.( It. No 3.7 Electrical Sr 2023-24 Page. No 9)No646.0646.01.0FalseNoneNoneFalseNoneFalse646.00
3286179114172NonePREE21Supplying and drawing PVC insulated flexible copper wire of approved make..23/0.0040” ( It. No 2.4.2 Electrical Sr 2023-24 Page. No 6)Mtr22.022.0120.0FalseNoneNoneFalseNoneFalse2640.00
3286180114172NonePREE22Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.1.5 sqmm ( It. No 2.3.2 Electrical Sr 2023-24 Page. No 6)Mtr26.026.0120.0FalseNoneNoneFalseNoneFalse3120.00
3286181114172NonePREE23Supplying 6A flush type socket and 6 amps flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3654 ( It. No 3.1 Electrical Sr 2023-24 Page. No 8)No128.0128.04.0FalseNoneNoneFalseNoneFalse512.00
3286182114172NonePREE24Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. ( It. No 3.6.1 Electrical Sr 2023-24 Page. No 9)No102.0102.010.0FalseNoneNoneFalseNoneFalse1020.00
3286183114172NonePREE25Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 4-5Way ( It. No 3.3.3 Electrical Sr 2023-24 Page. No 8)No137.0137.02.0FalseNoneNoneFalseNoneFalse274.00
3286184114172NonePREE26Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 3 Module ( It. No 3.5.2 Electrical Sr 2023-24 Page. No 8)No161.0161.02.0FalseNoneNoneFalseNoneFalse322.00
3286185114172NonePREE27Supplying PVC/GI flexible conduit pipe…mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300mm using NF screws and on either end of the pipe terminated completely ( It. No 1.9.2 Electrical Sr 2023-24 Page. No 3)Mtr22.022.010.0FalseNoneNoneFalseNoneFalse220.00
3286186114172NonePREE28Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S' hook with fan regulator to the existing board together with supplying and fixing 5 amps. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring.( It. No 13.10 Electrical Sr 2023-24 Page. No 57)No171.0171.02.0FalseNoneNoneFalseNoneFalse342.00
3286187114172NonePREE29Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts,50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system.48" Sweep (1200mm) Regular model( It. No 6.3.1 Electrical Sr 2023-24 Page. No 30)No2984.02984.02.0FalseNoneNoneFalseNoneFalse5968.00
3286188114172NonePREE30Fixing all types and all capacities of 1'x4' / 2'x2' LED Light fittings indoor on the wall / ceiling / rafters / girders with necessary supporting frame, using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps..( It. No 13.19 Electrical Sr 2023-24 Page. No 58)No490.0490.04.0FalseNoneNoneFalseNoneFalse1960.00
3286189114172NonePREE31Supplying of ......feet - PVC Batten with integrated LED tube.....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI more then 80. Power Input: 220-240V @ 50/60Hz & Power factor more then 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.LED light fitting 1 x 4' - 36/40 W( It. No 11.3.3 Electrical Sr 2023-24 Page. No 43)No1269.01269.02.0FalseNoneNoneFalseNoneFalse2538.00
3286190114172NonePREE32Supplying of recess mounting non integrated type LED down light ...... W luminaire comprising of pressure decast/extruded aluminium housing, with spring loaded false ceiling clamps, LED of Power/COB with CCT 6500 degree K, CRI more then 70%. efficacy 100 lumen per watt, 120degree beam spread, life more then 25000 burning hours and ompliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhancesthe lighting level. LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF more then 0.95, power loss should less then 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.1) 5-6W( It. No 11.4.1 Electrical Sr 2023-24 Page. No 44)No805.0805.02.0FalseNoneNoneFalseNoneFalse1610.00
3286191114172NonePREE33Supplying & Fixing of 70-150 Watts lamp holder 2 Pin( It. No 12.46 Electrical Sr 2023-24 Page. No 52)No63.063.05.0FalseNoneNoneFalseNoneFalse315.00
3286192114172NonePREE34Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet..Short point upto 3m from tapping point to out let via switch box( It. No 2.2.1 Electrical Sr 2023-24 Page. No 5)No269.0269.03.0FalseNoneNoneFalseNoneFalse807.00
3286193114172NonePREE35Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40mm dia 2.90mm thick GI pipe 2.5 mtr long buried in a pit … The pit should be filled with equal proportion of salt and charcoal 150mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per ISI specification 7.3.3. of IS 732 using 12mm dia bolts, nuts,washers and check( It. No 6.1 Electrical Sr 2019-20 Page. No 40)No2999.72999.71.0FalseNoneNoneFalseNoneFalse2999.70
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17182840850000NoneNoneELIGIBILITYBIDDERS SHALL NOT BE UNDER A DECLARATION OF INELIGIBILITY FOR CORRUPT AND FRAUDULENT PRACTICES ISSUED BY ANY STATE GOVERNMENT / GOVERNMENT OF INDIA /UNION TERRITORY.None
17182840850000NoneNoneELIGIBILITYTO ENSURE BROWSER COMPATIBILITY OF THE COMPUTER WELL IN ADVANCE TO THE LAST DATE AND TIME FOR RECEIPT OF TENDERS THE DEPARTMENTS SHALL NOT BE RESPONSIBLE FOR NON ACCESSIBILITY OF E-PROCUREMENT PORTAL DUE TO INTERNET CONNECTIVITY ISSUES AND TECHNICAL GLITCHES AT BIDDERS END.None
17182840850000NoneNoneELIGIBILITYEMD PAYMENTS THROUGH E-PAYMENT MODE SHALL BE MADE AS ONE SINGLE TRANSACTION AND PAYMENTS MADE IN PART ARE LIABLE FOR REJECTION.None
17182840850000NoneNoneELIGIBILITYBIDDER SHALL PAY CONTRACT MANAGEMENT MODULE PROCESSING FEES OF 0.025% OF THE CONTACT VALUE (MIN RS.500/- & MAX RS.7500/-) SOON AFTER CONTRACT HAS BEEN ISSUED TO BIDDER.None
17182840850000NoneNoneELIGIBILITYFOR DETAILS REFER TENDER NOTIFICATION AND CONDITIONS IN THE BID DOCUMENTS.None
17182840850000NoneNoneELIGIBILITYALL MATERIALS SHOULD BE IN GOOD QUALITY AS PER SPECIFICATION, QUALITY CERTIFICATE FOR THE SAME SHOULD BE OBTAINED FROM THE CONCERNED AUTHORITY AT THEIR OWN COST.None
17182840850000NoneNoneELIGIBILITYACCEPTENCE / CANCELLATION OF THE WORKS ARE RESERVED BY UNDER SIGNED WITHOUT ANY REASONS FOR THE SAME.None
17182840850000NoneNoneELIGIBILITYCORRIGENDUMS / MODIFICATIONS / CORRECTION, IF ANY, WILL BE PUBLISHED IN THE WEBSITE ONLY.None
17182840850000NoneNoneELIGIBILITYALL THE SCANNED DOCUMENTS PERTAINING TO BIDDER TO BE UPLOADED SHALL BE IN ORIGINAL AND SAME ORIGINALS SHOULD BE PRODUCED TO THE EXECUTIVE ENGINEER (AT THE TIME OF TECHNICAL BID OPENING) WHO RESERVES RIGHT TO VERIFY THE ORGINAL DOCUMENTS BEFORE APPROVAL.None
17182840850000NoneNoneELIGIBILITYTO QUALIFY FOR AWARD OF THIS CONTRACT EACH TENDERER SHOULD GIVE ALL DETAILS AND DOCUMENTS AS PER TECHNICAL AND FINANCIAL BID ATTACHED TO THIS TENDER.None
17182840850000NoneNoneELIGIBILITYALL THE MATERIALS TO BE UTILISED FOR THE WORK MUST BE TESTED IN RWS SE OFFICE DHARWAD LABS AND QUALITY CONTROL TEST REPORTS MUST BE ENCLOSED TO THE BILLS. COST OF ALL QC TEST MUST BE BORNE BY CONTRACTOR.None
17182840850000NoneNoneELIGIBILITYIF ANY DATE IN THE TENDER TIME TABLE IS GOVERNMENT HOLIDAY, NEXT WORKING DATE WILL BE CONSIDEREDNone
17182840850000NoneNoneELIGIBILITYTENDERER MUST SUBMIT HIS PRESENT ACCURATE POSTAL ADDRESS AND PHONE / CELL PHONE NUMBERNone
17182840850000NoneNoneELIGIBILITYTHE TENDER MAY BE CANCELLED AT ANY STAGE WITHOUT ASSIGNING ANY REASONNone
17182840850000NoneNoneELIGIBILITYTENDERERS MUST HAVE VALID PWD REGISTRATION COPYNone
17182840850000NoneNoneELIGIBILITYTHE RATES OF ITEMS ARE INCLUSIVE OF COST OF MATERIALS, LABOUR CHARGES, HOM OF MACHINERY, ALL LEAD AND LIFTS AND ALL OTHER CHARGES TO COMPLETE THE WORK SUCCESSFULLY AS PER SPECIFICATIONS AND AS DIRECTED BY ENGINEER IN CHARGE OF WORKNone
17182840850000NoneNoneELIGIBILITYSIMILAR NATURE OF WORK DONE CERTIFICATE - MINIMUM 50% OF AMOUNT PUT TO TENDER ISSUED BY EXECUTIVE ENGINEER OR EQUIVALENT LAST 5 YEARS (2018-19 to 2022-23)None
17182840850000NoneNoneELIGIBILITYTHE BIDDER MUST SUBMIT LAST 5 YEARS (2018-19 to 2022-23) PROFIT AND LOSS ACCOUNT OBTAINED FROM CHARTERED ACCOUNTANT (CA) ONLY. BIDDER MUST HAVE ANNUAL CONTRACT AVERAGE TURN OVER FOR 2 YEARS NOT LESS THAN THE AMOUNT PUT TO TENDER IN EACH FINANCIAL YEARS.None
17182840850000NoneNoneELIGIBILITYTHIRTY PERCENT OF ESTIMATE COST LIQUID ASSETS/BANK LINE OF CREDIT FROM ANY NATIONALIZED/SCHEDULED BANK MUST BE SUBMITTED AS PER KW BID DOCUMENTNone
17182840850000NoneNoneELIGIBILITYEIGHTEEN PERCENTAGE GST SHALL PAID SEPERATELYNone
17182840850000NoneNoneELIGIBILITYALL OTHER CONDITIONS AS PER KW TENDER DOCUMENTNone
preQualCriterionListNone
technicalCriterionListNone
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
PWD REGISTRATION CERTIFICATE .TrueTechnical Bid
ANNUAL TURN OVER CERTIFICATE OF LAST 5 YEARS ISSUED BY CATrueTechnical Bid
GST REGISTRATION CERTIFICATETrueTechnical Bid
FIFTY PERCENT OF SIMILAR NATURE OF WORKDONE CERTIFICATE ISSUED FROM EXECUTIVE ENGINEER.TrueTechnical Bid
ACCURATE POSTAL ADDRESS AND PHONE NUMBER AND EMAIL ADDRESSTrueTechnical Bid
THIRTY PERCENT OF ESTIMATE COST LIQUID ASSETS/BANK LINE OF CREDIT FROM ANY NATIONALIZED/SCHEDULED BANK MUST BE SUBMITTED AS PER KW BID DOCUMENTTrueTechnical Bid
tenderWorkLocationList
tenderAddressNone
tenderRecallDTONone