tenderSubEstimateList | createdTs | version | createdDate | modifiedDate | workCategoryName | subEstimateName | estimateTotal | itemList |
---|
1717569405000 | 0 | None | None | Roads | Pavement Construction | 465589030.04 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3230530 | 111453 | None | Volume3 | Providing and Fixing Logo of PMGSY Project Providing and fixing of typical PMGSY informatory sign board with Logo as per MORD specifications and drawing. i)The board will be a composite unit consisting of three plates of Aluminium Composite Materials (ACM), material specifications as per Clause 1701.3.7. The top most platewill be in diamond shape of 600mm x 600 mm size, riveted over welded M.S. angle iron frame of 25 mm x 25mm x 5 mm size on back on edges. The middle plate will be 1200 mm x 150 mm size riveted over welded M.S. angle iron frame of 25mm x 25mmx 5 mm size on back on edges. The main lower most plate will be 1500 mm x 600 mm size, riveted over welded M.S. angle iron frame of 25 mm x 25 mm x 5 mm size. Welding of all the sheets over angle iron frame will be done neatly to have plain surface on one side. The angle iron frames of the lower most plate and the middle plate will be welded to two nos. 75 mm x 75 mm (12 SWG) sheet tubes posts placed at 1125 mm apart centre to centre. The top of the middle plate will be flushed with the top of 75 mm tube posts and these posts will be embedded in cement concrete M15 grade blocks of 450 mm x 450 mm x 600 mm below ground level. The height of bottom of the lower most plate will be 1200 mm from normal ground level and the bottom of middle plate will be 100 mm above the top level of the lower most plate. The diamond shaped plate mounted over angle iron frame will be connected to middleplate by square medium steel section of 47 mm x 47 mm thickness 12 SWG having a spacing of 100 mm between the diamond shaped plate and middle plate. and this square section will be welded to the bottom point of the diamond shaped plate. (ii) The lettering and borders, etc. of middle and bottom plate, PMGSY logo on top plate shall be as per clause 1701.4.6 essages/Borders. All the sections of frame and posts will be painted with primer and two coats of Epoxy paint. The steel tube below ground level will be painted with three coats of Epoxy paint. The design, painting and lettering shall be done as per approved drawing. (iii) For warranty and durability the clause 1701.5 and for maintenance the clause 1911 shall be applicable. (iv) A reference number along with the month and year of installation should be placed on the back of a sign in a contrasting colour or by stamping in characters not exceeding 50 mm in height.485777/2019/Dir(Tech) 7 A Retro Reflective Trafic Sign As per IRC 67 Clause 1701.3.8.1 Class A Type-1 For Project Information Board V-3 Item no 16.29 Page no 149 | Each | 16119.6 | 16119.6 | 2.0 | False | None | None | False | None | False | 32239.2 | 0 | 3230531 | 111453 | None | Volume3 | Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. By Mechanical Means using Dozer, In area of light jungle V-3 Item no 2.5(ii)A Page no 09 | 100 Sqm | 412.65 | 412.65 | 248.76 | False | None | None | False | None | False | 102650.814 | 0 | 3230532 | 111453 | None | Volume3 | Scarifying the existing bituminous road surface to a depth of 50 mm and disposal of scarified material by Mechanical Means using Hydraulic excavator with in all lifts and lead MORTH Specification No. 305.4.3 V-3 Item no 3.5 Page no 17 | Sqm | 6.3 | 6.3 | 95386.0 | False | None | None | False | None | False | 600931.8 | 0 | 3230533 | 111453 | None | Volume1 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications,including setting out, shoring, strutting, barricading, caution lights,including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. (In all kinds of soils Depth upto 3 m) V-1 Item no 1.14.1 Page no 08 | Cum | 107.1 | 107.1 | 24774.9 | False | None | None | False | None | False | 2653391.79 | 0 | 3230534 | 111453 | None | Volume3 | Removal of Unserviceable Soil with Disposal upto a suitable distance as directed by the Engineer incharge of work, MORTH Specification No. 301 V-3 Item no 3.1 Page no 17 | Cum | 89.25 | 89.25 | 4342.5 | False | None | None | False | None | False | 387568.125 | 0 | 3230535 | 111453 | None | Volume1 | Construction of Embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded with desired compaction. V-1 Item no 1.7 Page no 07 | Cum | 124.95 | 124.95 | 20432.39 | False | None | None | False | None | False | 2553027.1305 | 0 | 3230536 | 111453 | None | Volume1 | Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. V-1 Item no 1.8 Page no 34 | Cum | 497.7 | 497.7 | 13264.27 | False | None | None | False | None | False | 6601627.179 | 0 | 3230537 | 111453 | None | Volume3 | Construction of sub-grade and earthen shoulders with approved material obtained from borrow pits with all lifts & leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of table No. 300-2 V-3 Item no 3.6 Page no 17 | Cum | 517.65 | 517.65 | 11214.0 | False | None | None | False | None | False | 5804927.1 | 0 | 3230538 | 111453 | None | Volume3 | Construction of Granular Sub-Base of required grading as per design mixing in a mechanical mix plant at OMC carriage of mixed Material to work site, spreading in uniform layers with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per clause 401 V)For Grading -V Material MORTH Specification No. 401 (V-3 Item no 4.1 A(V) Page no 23) | Cum | 2611.35 | 2611.35 | 19707.95 | False | None | None | False | None | False | 51464355.2325 | 0 | 3230539 | 111453 | None | Volume3 | Dry Lean Cement Concrete Sub-base 601 Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 14:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 140 kg/ m3 , optimum moisture content to be determined during trial length construction, concrete strength not to be less than 7 Mpa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 t vibratory roller, finishing and curing. V-3 Item no 6.1 Page no 49 | Cum | 5166.0 | 5166.0 | 14591.75 | False | None | None | False | None | False | 75380980.5 | 0 | 3230540 | 111453 | None | Volume3 | Pavement Quality Concrete using paver - M40 grade Construction of un-reinforced, dowel jointed M40 grade Pavement Quality Concrete Pavement over a prepared sub base in recommended proportions, Coarse and Fine aggregate conforming to IS 383:2016, maximum size of coarse aggregate not exceeding 31.5 mm, mixed in a batching and mixing plant as per approved mix design, limiting water cement ratio to maximum 0.40 to achieve minimum flexural strength or modulus of rupture of Concrete being 4.5MPa transported to site, laid with a slip form paver finisher, spread, compacted and finished in a continuous operation including provision of texturing, contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant as per IRC 57: 2018, debonding strip, dowel bar, tie rod, admixtures, curing compound, steel channels, finishing to lines and grades as per drawing (Reference to MORTH Specification 602 along with IRC 15: 2017) V-3 Item no 6.2.1 Page no 49 | Cum | 9514.05 | 9514.05 | 30779.92 | False | None | None | False | None | False | 292841697.876 | 0 | 3230541 | 111453 | None | Volume3 | Providing and constructing un-reinforced plain cement
concrete pavement, thickness as per design, over a prepared
sub base, with 43 grade cement or any other type as per
Clause 1501.2.2 M30 (Grade), coarse and fine aggregates
conforming to IS:383:2016:, maximum size of coarse
aggregate not exceeding 25 mm, mixed in a concrete mixer
of not less than 0.2 cum capacity and appropriate weigh
batcher using approved mix design, laid in approved fixed
side formwork (steel channel, laying and fixing of 125 micron
thick polythene film, wedges, steel plates including levelling
the formwork as per drawing), spreading the concrete with
shovels, rakes, compacted using needle, screed and plate
vibrators and finished in continuous operation including
construction joints, primer, sealant, curing of concrete slabs
for 14-days, and water finishing to lines and grade as per
drawing and technical specification clause 1501 with all
lead, lifts, loading & unloading charges, cost and conveyance
of all materials, labour, equipments etc., complete. as per the
directions of the Engineer-in-charge of the work V-3 Item no 16.28 Page no 149 | Cum | 7091.7 | 7091.7 | 794.14 | False | None | None | False | None | False | 5631802.638 | 0 | 3230542 | 111453 | None | Volume1 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates V-1 Item no 2.1.4 Page no 15 | Cum | 6527.85 | 6527.85 | 23.4 | False | None | None | False | None | False | 152751.69 | 0 | 3230543 | 111453 | None | Volume1 | Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates V-1 Item no 2.3.1 Page no 16 (The Cost of Form work Included) | Cum | 7303.06 | 7303.06 | 851.59 | False | None | None | False | None | False | 6219212.8654 | 0 | 3230544 | 111453 | None | Volume3 | Providing and laying 80mm thick factory made precast M -30 grade Cement Concrete Paver Block as per IRC SP 63:2018 & IS 15658 for Commercial Traffic Axle load repetitions upto 10MSA & for Residential Streets of approved shape and colour, laid in required pattern and including over 40mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge. (WMM/WBM Base to be paid separately as per relevant technical specification) V-3 Item no 6.8.2 Page no 51 | Sqm | 1219.05 | 1219.05 | 5652.0 | False | None | None | False | None | False | 6890070.6 | 0 | 3230545 | 111453 | None | Volume3 | Wet Mix Macadam (Plant mix method), Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver/grader in sub-base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density. V-3 Item no 4.17 Page no 26 | Cum | 2686.95 | 2686.95 | 1413.0 | False | None | None | False | None | False | 3796660.35 | 0 | 3230546 | 111453 | None | Volume1 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening,cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. All other type of structuresVolume 1 Item no 2.11(h) page no 18 | Tonne | 82961.55 | 82961.55 | 4.68 | False | None | None | False | None | False | 388260.054 | 0 | 3230547 | 111453 | None | Volume3 | Providing and laying of a reinforced cement concrete pipe duct, 300 mm dia, across the road (new construction), extending from drain to drain in cuts and toe of slope to toe of slope in fills, constructing head walls at both ends, providing a minimum fill of granular material over top and sides of RCC pipe as per IRC:98-1997, bedded on a 0.3 m thick layer of granular material free of rock pieces, outer to outer distance of pipe at least half dia of pipe subject to minimum 450 mm in case of double and triple row ducts, joints to be made leak proof, invert level of duct to be above higher than ground level to prevent entry of water and dirt, all as per IRC: 98 -1997 and approved drawings. (ii)Double row for two utility services V-3 Item no 8.29 Page no 71 | m | 4209.45 | 4209.45 | 760.0 | False | None | None | False | None | False | 3199182.0 | 0 | 3230548 | 111453 | None | Volume3 | Providing and laying Pitching on slopes laid over prepared filter media including boulder apron laid dry in front of toe of embankment complete as per drawing and Technical specifications Stone/Boulder V-3 Item no 14.4A Page no 129 | Cum | 2007.6 | 2007.6 | 150.0 | False | None | None | False | None | False | 301140.0 | 0 | 3230549 | 111453 | None | Volume3 | Providing and laying Filter material underneath pitching in slopes complete as per drawing and Technical specification Volume 3 Item no 14.5 page no 129 | Cum | 3187.8 | 3187.8 | 75.0 | False | None | None | False | None | False | 239085.0 | 0 | 3230550 | 111453 | None | Volume3 | Maintenance of Slab type Culverts by way of clearing, Cleaning, Erosion repair, repairs to cracks, parapet walls and Protection works as per drawing and technical specification. V-3 Item no 16.20(ii) Page no 147 | No | 4547.55 | 4547.55 | 3.0 | False | None | None | False | None | False | 13642.65 | 0 | 3230551 | 111453 | None | Volume3 | Providing and laying Filter material underneath pitching in slopes complete as per drawing and Technical specification Volume 3 Item no 14.5 page no 129 | No | 2149.35 | 2149.35 | 7.0 | False | None | None | False | None | False | 15045.45 | 0 | 3230552 | 111453 | None | Volume3 | Dismantling kerb stone by manual means and disposal of dismantled material with all lifts and lead V-3 Item no 2.21 page no 12 | m | 23.1 | 23.1 | 13800.0 | False | None | None | False | None | False | 318780.0 | 0 |
| 1717569405000 | 0 | None | None | Roads | Construction of Field Culverts | 2374194.96 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3230553 | 111454 | None | Volume1 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work 1.14.1 In all kinds of soils Depth upto 3 m Volume 1 Item no 1.14.1 page no 8 | Cum | 107.1 | 107.1 | 263.9 | False | None | None | False | None | False | 28263.69 | 0 | 3230554 | 111454 | None | Volume1 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates Volume 1 Item no 2.1.3 page no 15 | Cum | 6288.45 | 6288.45 | 27.6 | False | None | None | False | None | False | 173561.22 | 0 | 3230555 | 111454 | None | Volume1 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (the cost of form work included) Volume 1 Item no 2.4.2 page no 16 | Cum | 6971.11 | 6971.11 | 191.76 | False | None | None | False | None | False | 1336780.0536 | 0 | 3230556 | 111454 | None | Volume3 | Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1101.6 B) 1000mm Dia.Volume 3 Item no 16.15(b) page no 146 | m | 8355.9 | 8355.9 | 100.0 | False | None | None | False | None | False | 835590.0 | 0 |
| 1717569405000 | 1 | None | None | Roads | Construction of RCC Drain and Road Crossings | 16474036.39 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3230557 | 111455 | None | Volume1 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications,including setting out, shoring, strutting, barricading, caution lights,including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. (In all kinds of soils Depth upto 3 m) V-1 Item no 1.14.1 Page no 08 | Cum | 107.1 | 107.1 | 3456.0 | False | None | None | False | None | False | 370137.6 | 0 | 3230558 | 111455 | None | Volume1 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 40 mm and down size graded crushed coarse aggregates PWD CSR 2023-24 V-1 Item no 2.1.3 Page no 15 | Cum | 6288.45 | 6288.45 | 360.0 | False | None | None | False | None | False | 2263842.0 | 0 | 3230559 | 111455 | None | Volume3 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening,cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. All other type of structuresVolume 1 Item no 2.11(h) page no 18 | Tonne | 82961.55 | 82961.55 | 37.24 | False | None | None | False | None | False | 3089488.122 | 0 | 3230560 | 111455 | None | Volume3 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (V-1 I.No. 2.2.1 P.No.15) | Cum | 6799.39 | 6799.39 | 324.85 | False | None | None | False | None | False | 2208781.8415 | 0 | 3230561 | 111455 | None | Volume1 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials
of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications M20 Design Mix Using 20 mm and down size graded crushed coarse aggregates V-1 Item no 2.4.2 Page no 16 (The Cost of Form work Included) | Cum | 8962.85 | 8962.85 | 432.0 | False | None | None | False | None | False | 3871951.2 | 0 | 3230562 | 111455 | None | Volume2 | Providing and laying 100mm thick pre-cast cover slabs over Road side drains / utility ducts / Rain water harvesting pit of width not exceeding 1000 mm using M20 concrete reinforced with TMT bars Fe 550 @ 6kg/ m2, slabs jointed in CM 1:3 proportion and nicely finished Including providing holes in the Cover slabs wherever necessary for easy drainage of surface water including of labour, materials, scaffolding, usage of machinery, curing, lead and lift charges etc, Complete. (V-2 I.No. 17.14 P.No.17.7) | Sqm | 1228.5 | 1228.5 | 3801.25 | False | None | None | False | None | False | 4669835.625 | 0 |
| 1717569405000 | 0 | None | None | Roads | Road Furniture | 6838846.66 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3230563 | 111456 | None | Volume3 | Reinforced cement concrete M15grade kilometre stone of standard design as per IRC:8-1980, fixing in position including painting and printing etc, 5th kilometre stone (precast) MORTH Specification No. 805 V-3 Item no 8.16 (i) Page no 67 | Each | 5335.05 | 5335.05 | 2.0 | False | None | None | False | None | False | 10670.1 | 0 | 3230564 | 111456 | None | Volume3 | Reinforced cement concrete M15grade kilometre stone of standard design as per IRC:8-1980, fixing in position including painting and printing etc (ii) Ordinary kilometer stone (precast) MORTH Specification No. 805 V-3 Item no 8.16 (ii) Page no 67 | Each | 3073.35 | 3073.35 | 11.0 | False | None | None | False | None | False | 33806.85 | 0 | 3230565 | 111456 | None | Volume3 | Reinforced cement concrete M15grade kilometre stone of standard design as per IRC:8-1980, fixing in position including painting and printing etc (iii) 200 m stone (precast) MORTH Specification No. 805 V-3 Item no 8.16 (iii) Page no 67 | Each | 884.1 | 884.1 | 52.0 | False | None | None | False | None | False | 45973.2 | 0 | 3230566 | 111456 | None | Volume3 | Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads @ 250 g/ m2 area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35:2015.The finished surface to be level, uniform and free from streaks and holes. MORTH Specification No. 803 V-3 Item no 8.15 Page no 67 | Sqm | 556.5 | 556.5 | 7050.85 | False | None | None | False | None | False | 3923798.025 | 0 | 3230567 | 111456 | None | Volume3 | Retro-Reflectorised Traffic Signs Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign as per IRC:67:2022 made of Class B Type IV retro reflective sheeting fixed over 2 mm thick aluminium sheeting vide clause 803.1, 3mm/4mm thick Aluminium composite material sheet depending on the size of the sign fixed over the back support frame of min 25 x 25 x 3mm angle mounted on a mild steel circular pipe 65 NB, 3.2 mm thickness firmly fixed to the ground by means of properly designed foundation with M25 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing.The sign shall be maintained as per section 12 of IRC:67:2022. 90 cm equilateral triangle V-3 Item no 8.5 Page no 63 (ii) | Each | 4918.2 | 4918.2 | 47.0 | False | None | None | False | None | False | 231155.4 | 0 | 3230568 | 111456 | None | Volume3 | Retro-Reflectorised Traffic Signs Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign as per IRC:67:2022 made of Class B Type IV retro reflective sheeting fixed over 2 mm thick aluminium sheeting vide clause 803.1, 3mm/4mm thick Aluminium composite material sheet depending on the size of the sign fixed over the back support frame of min 25 x 25 x 3mm angle mounted on a mild steel circular pipe 65 NB, 3.2 mm thickness firmly fixed to the ground by means of properly designed foundation with M25 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing.The sign shall be maintained as per section 12 of IRC:67:2022. 60 cm circularV-3 Item no 8.5 (viii) Page no 63 | Each | 4511.85 | 4511.85 | 23.0 | False | None | None | False | None | False | 103772.55 | 0 | 3230569 | 111456 | None | Volume3 | Retro-Reflectorised Traffic Signs Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign as per IRC:67:2022 made of Class B Type IV retro reflective sheeting fixed over 2 mm thick aluminium sheeting vide clause 803.1, 3mm/4mm thick Aluminium composite material sheet depending on the size of the sign fixed over the back support frame of min 25 x 25 x 3mm angle mounted on a mild steel circular pipe 65 NB, 3.2 mm thickness firmly fixed to the ground by means of properly designed foundation with M25 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing.The sign shall be maintained as per section 12 of IRC:67:2022. 60 cm x 45 cm rectangular V-3 Item no 8.5 (xii) Page no 64 | Each | 4435.2 | 4435.2 | 112.0 | False | None | None | False | None | False | 496742.4 | 0 | 3230570 | 111456 | None | Volume3 | Retro-Reflectorised Traffic Signs Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign as per IRC:67:2022 made of Class B Type IV retro reflective sheeting fixed over 2 mm thick aluminium sheeting vide clause 803.1, 3mm/4mm thick Aluminium composite material sheet depending on the size of the sign fixed over the back support frame of min 25 x 25 x 3mm angle mounted on a mild steel circular pipe 65 NB, 3.2 mm thickness firmly fixed to the ground by means of properly designed foundation with M25 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing.The sign shall be maintained as per section 12 of IRC:67:2022. 90 cm high octagon V-3 Item no 8.5 (xv) Page no 54 | Each | 6827.1 | 6827.1 | 7.0 | False | None | None | False | None | False | 47789.7 | 0 | 3230571 | 111456 | None | Volume3 | Direction and Place Identification Signs upto 0.9 m2 Size Board.Providing and erecting direction and place identification retro-reflectorised sign as per IRC:67:2012 made of high intensity grade sheeting vide clause 801.3, fixed over aluminium sheeting, 2 mm thick or Aluminium composite material sheet with overall thickness of 4mm with area not exceeding 0.9 m2 fixed over back support frame of min 35 x 35 x 3mm angle mounted on a mild steel circular pipe 65 NB, firmly fixed to the ground by means of roperly designed foundation with M25 grade cement concrete 45 x 45 x 60 cm, 60 cm below ground level as per approved drawing. MORTH Specification No. 801 V-3 Item no 8.7 Page no 65 | Sqm | 9460.5 | 9460.5 | 4.5 | False | None | None | False | None | False | 42572.25 | 0 | 3230572 | 111456 | None | Volume3 | Direction and Place Identification Signs with size more
than 0.9 m2 size Board.Providing and erecting direction and place identification retroreflectorised sign as per IRC:67:2022 made of high intensity grade sheeting vide clause 801.3, fixed over aluminium sheeting, 2 mm thick or Aluminium composite material sheet with overall thickness of 4mm with area exceeding 0.9 m2 fixed over back support frame of min 40 x 40 x 5mm angle mounted on a mild steel circular pipe 65 NB, firmly fixed to the ground by means of properly designed foundation with M25 grade cement concrete 45 x 45 x 60 cm, 60 cm below ground level as per approved drawing V-3 Item no 8.8 Page no 65 | Sqm | 10187.1 | 10187.1 | 18.9 | False | None | None | False | None | False | 192536.19 | 0 | 3230573 | 111456 | None | Volume3 | Supplying and Fixing of Molded Shank Raised Pavement Markers / Cat's Eye made of polycarbonate and ABS moulded body and reflective panels with micro prismatic lens capable of providing total internal reflection of the light entering the lens face and shall support a load of 16000 kg tested in accordance to ASTM D 4280 Type H and complying to Specifications of Category A of MORTH Circular No RW/NH/33023/10-97 DO III Dt 11.06. 1997. The height, width and length shall not exceed 50 mm, 100 mm and 102 +/- 2 mm and with minimum reflective area of 1 cm2 n each side and the slope to the base shall be 35 +/- 5 degree. The strength of detachment of the integrated cylindrical shanks, (of diameter not less than 19 +/- 2 mm and height not less than 30+/- 2 mm) fromthe body is to be a minimum value of 500 Kg. Fixing will be by drilling holes on the road for the shanks to go inside, without nails and using epoxy resin based adhesive as per manufacturer's commendation and complete as directed by the engineer.The contractor shall submit a two year warranty for satisfactory field performance including tipulated retro-reflectance of the reflecting panel, to the Engineer. MORTH Specification No. 806 V-3 Item no 8.43 Page no 74 | No | 383.25 | 383.25 | 3576.0 | False | None | None | False | None | False | 1370502.0 | 0 | 3230574 | 111456 | None | Volume3 | Road Delineators Supplying and installation of delineators (road way indicators, hazard markers, object markers), 80-100 cm high above ground level, painted black and white in 15 cm wide strips, fitted with 80 x 100 mm rectangular or 75 mm dia circular reflectorised panels at the top, buried or pressed into the ground and conforming to IRC-79-2019 and the drawings. V-3 Item no 8.17 Page no 67 | Each | 2122.05 | 2122.05 | 160.0 | False | None | None | False | None | False | 339528.0 | 0 |
| 1717569406000 | 1 | None | None | Roads | Re Construction of Box Culvert at Chainage 5. 931 | 1948260.47 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3230575 | 111457 | None | Volume3 | Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete,wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead By Mechanical Means Cement Concrete Grade M-15 & M-20V-3, P.No 10 I.No 2.8 (ii a) | Cum | 754.95 | 754.95 | 5.62 | False | None | None | False | None | False | 4242.819 | 0 | 3230576 | 111457 | None | Volume3 | Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete,wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead By Mechanical means Dismantling Brick / Tile work / rubble masonry / pitching / etc by mechanical means V-3, P.No 10 I.No 2.11 (ii a) | Cum | 189.0 | 189.0 | 18.18 | False | None | None | False | None | False | 3436.02 | 0 | 3230577 | 111457 | None | Volume1 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m V-1 Item no 1.14.1 Page no 8 | Cum | 107.1 | 107.1 | 273.79 | False | None | None | False | None | False | 29322.909 | 0 | 3230578 | 111457 | None | Volume1 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates V-1 Item no 2.1.3 Page no 15 | Cum | 6288.45 | 6288.45 | 28.28 | False | None | None | False | None | False | 177837.366 | 0 | 3230579 | 111457 | None | Volume3 | Providing and laying of Filter media with granular materials/ stone crushed aggregates satisfying the requirements laid down in clause 2504.2.2. of MoRTH specifications to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and provided over the entire surface behind abutment, wing wall and return wall to the full height compacted to a firm condition complete as per drawing and Technical Specification. Volume 3 Item no 12.4 page no 117 | Cum | 2810.85 | 2810.85 | 79.75 | False | None | None | False | None | False | 224165.2875 | 0 | 3230580 | 111457 | None | Volume3 | Curtain wall complete as per drawing and Technical specification Cement concrete Grade M15 Volume 3 Item no 14.8 (b) page no 130 | Cum | 6555.15 | 6555.15 | 37.34 | False | None | None | False | None | False | 244769.301 | 0 | 3230581 | 111457 | None | Volume3 | Painting on concrete surface Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ of 1 litre for 2 m2. Volume 3 Item no 13.14 page no 123 | Sqm | 88.2 | 88.2 | 10.5 | False | None | None | False | None | False | 926.1 | 0 | 3230582 | 111457 | None | Volume3 | Providing and laying Pitching on slopes laid over prepared filter media including boulder apron laid dry in front of toe of embankment complete as per drawing and Technical specifications Stone/ Boulder Volume 3 Item no 14.4 (A) page no 129 | Cum | 2007.6 | 2007.6 | 15.43 | False | None | None | False | None | False | 30977.268 | 0 | 3230583 | 111457 | None | Volume3 | Providing and laying Filter material underneath pitching in slopes complete as per drawing and Technical specification Volume 3 Item no 14.5 page no 129 | Cum | 3187.8 | 3187.8 | 7.72 | False | None | None | False | None | False | 24609.816 | 0 | 3230584 | 111457 | None | Volume3 | Providing and laying boulders apron on river bed for protection against scour with stone boulders weighing not less than 40 kg each complete as per drawing and Technical specification.Boulder Laid Dry Without Wire Crates. Volume 3 Item no 14.1 (A) page no 129 | Cum | 2007.6 | 2007.6 | 14.44 | False | None | None | False | None | False | 28989.744 | 0 | 3230585 | 111457 | None | Volume1 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening,cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. All other type of structures Volume 1 Item no 2.11(h) page no 18 | t | 82961.55 | 82961.55 | 5.92 | False | None | None | False | None | False | 491132.376 | 0 | 3230586 | 111457 | None | Volume3 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. .V-1 Item no 2.2.3 Page no 15 M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (The Cost of Form work Included) ( V-3 Item no 2.2.3 Page no 15) | Cum | 6852.38 | 6852.38 | 39.16 | False | None | None | False | None | False | 268339.2008 | 0 | 3230587 | 111457 | None | Volume1 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates V-1 Item no 2.4.3 Page no 16 (The Cost of Form work Included) | Cum | 7983.36 | 7983.36 | 18.63 | False | None | None | False | None | False | 148729.9968 | 0 | 3230588 | 111457 | None | Volume1 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates V-1 Item no 2.4.3 Page no 16 (The Cost of Form work Included) | Cum | 7318.08 | 7318.08 | 22.52 | False | None | None | False | None | False | 164803.1616 | 0 | 3230589 | 111457 | None | Volume1 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates V-1 Item no 2.4.3 Page no 16 (The Cost of Form work Included) | Cum | 9979.2 | 9979.2 | 10.62 | False | None | None | False | None | False | 105979.104 | 0 |
| 1717569406000 | 1 | None | None | Roads | Re Construction of Box Culvert at Chainage 6.112 | 1991542.48 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3230590 | 111458 | None | Volume3 | Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete,wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead By Mechanical Means Cement Concrete Grade M-15 & M-20V-3, P.No 10 I.No 2.8 (ii a) | Cum | 754.95 | 754.95 | 5.62 | False | None | None | False | None | False | 4242.819 | 0 | 3230591 | 111458 | None | Volume3 | Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete,wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead By Mechanical means Dismantling Brick / Tile work / rubble masonry / pitching / etc by mechanical means V-3, P.No 10 I.No 2.11 (ii a) | Cum | 189.0 | 189.0 | 18.18 | False | None | None | False | None | False | 3436.02 | 0 | 3230592 | 111458 | None | Volume1 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m V-1 Item no 1.14.1 Page no 8 | Cum | 107.1 | 107.1 | 274.96 | False | None | None | False | None | False | 29448.216 | 0 | 3230593 | 111458 | None | Volume1 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates V-1 Item no 2.1.3 Page no 15 | Cum | 6288.45 | 6288.45 | 28.42 | False | None | None | False | None | False | 178717.749 | 0 | 3230594 | 111458 | None | Volume3 | Providing and laying of Filter media with granular materials/ stone crushed aggregates satisfying the requirements laid down in clause 2504.2.2. of MoRTH specifications to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and provided over the entire surface behind abutment, wing wall and return wall to the full height compacted to a firm condition complete as per drawing and Technical Specification. Volume 3 Item no 12.4 page no 117 | Cum | 2810.85 | 2810.85 | 81.44 | False | None | None | False | None | False | 228915.624 | 0 | 3230595 | 111458 | None | Volume3 | Curtain wall complete as per drawing and Technical specification Cement concrete Grade M15 Volume 3 Item no 14.8 (b) page no 130 | Cum | 6555.15 | 6555.15 | 37.61 | False | None | None | False | None | False | 246539.1915 | 0 | 3230596 | 111458 | None | Volume3 | Painting on concrete surface Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ of 1 litre for 2 m2. Volume 3 Item no 13.14 page no 123 | Sqm | 88.2 | 88.2 | 10.84 | False | None | None | False | None | False | 956.088 | 0 | 3230597 | 111458 | None | Volume3 | Providing and laying Pitching on slopes laid over prepared filter media including boulder apron laid dry in front of toe of embankment complete as per drawing and Technical specifications Stone/ Boulder Volume 3 Item no 14.4 (A) page no 129 | Cum | 2007.6 | 2007.6 | 15.42 | False | None | None | False | None | False | 30957.192 | 0 | 3230598 | 111458 | None | Volume3 | Providing and laying Filter material underneath pitching in slopes complete as per drawing and Technical specification Volume 3 Item no 14.5 page no 129 | Cum | 3187.8 | 3187.8 | 7.72 | False | None | None | False | None | False | 24609.816 | 0 | 3230599 | 111458 | None | Volume3 | Providing and laying boulders apron on river bed for protection against scour with stone boulders weighing not less than 40 kg each complete as per drawing and Technical specification.Boulder Laid Dry Without Wire Crates. Volume 3 Item no 14.1 (A) page no 129 | Cum | 2007.6 | 2007.6 | 14.65 | False | None | None | False | None | False | 29411.34 | 0 | 3230600 | 111458 | None | Volume1 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening,cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. All other type of structures Volume 1 Item no 2.11(h) page no 18 | t | 82961.55 | 82961.55 | 6.11 | False | None | None | False | None | False | 506895.0705 | 0 | 3230601 | 111458 | None | Volume3 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. .V-1 Item no 2.2.3 Page no 15 M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (The Cost of Form work Included) ( V-3 Item no 2.2.3 Page no 15) | Cum | 6852.38 | 6852.38 | 40.14 | False | None | None | False | None | False | 275054.5332 | 0 | 3230602 | 111458 | None | Volume1 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates V-1 Item no 2.4.3 Page no 16 (The Cost of Form work Included) | Cum | 7983.36 | 7983.36 | 19.29 | False | None | None | False | None | False | 153999.0144 | 0 | 3230603 | 111458 | None | Volume1 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates V-1 Item no 2.4.3 Page no 16 (The Cost of Form work Included) | Cum | 7318.08 | 7318.08 | 22.56 | False | None | None | False | None | False | 165095.8848 | 0 | 3230604 | 111458 | None | Volume1 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates V-1 Item no 2.4.3 Page no 16 (The Cost of Form work Included) | Cum | 9979.2 | 9979.2 | 11.35 | False | None | None | False | None | False | 113263.92 | 0 |
| 1717569406000 | 1 | None | None | Roads | Re Construction of Box Culvert at Chainage 9.380 | 1717597.58 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3230605 | 111459 | None | Volume3 | Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete,wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead By Mechanical Means Cement Concrete Grade M-15 & M-20V-3, P.No 10 I.No 2.8 (ii a) | Cum | 754.95 | 754.95 | 3.75 | False | None | None | False | None | False | 2831.0625 | 0 | 3230606 | 111459 | None | Volume3 | Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete,wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead By Mechanical means Dismantling Brick / Tile work / rubble masonry / pitching / etc by mechanical means V-3, P.No 10 I.No 2.11 (ii a) | Cum | 189.0 | 189.0 | 13.72 | False | None | None | False | None | False | 2593.08 | 0 | 3230607 | 111459 | None | Volume1 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m V-1 Item no 1.14.1 Page no 8 | Cum | 107.1 | 107.1 | 278.82 | False | None | None | False | None | False | 29861.622 | 0 | 3230608 | 111459 | None | Volume1 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates V-1 Item no 2.1.3 Page no 15 | Cum | 6288.45 | 6288.45 | 27.06 | False | None | None | False | None | False | 170165.457 | 0 | 3230609 | 111459 | None | Volume3 | Providing and laying of Filter media with granular materials/ stone crushed aggregates satisfying the requirements laid down in clause 2504.2.2. of MoRTH specifications to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and provided over the entire surface behind abutment, wing wall and return wall to the full height compacted to a firm condition complete as per drawing and Technical Specification. Volume 3 Item no 12.4 page no 117 | Cum | 2810.85 | 2810.85 | 63.14 | False | None | None | False | None | False | 177477.069 | 0 | 3230610 | 111459 | None | Volume3 | Curtain wall complete as per drawing and Technical specification Cement concrete Grade M15 Volume 3 Item no 14.8 (b) page no 130 | Cum | 6555.15 | 6555.15 | 39.22 | False | None | None | False | None | False | 257092.983 | 0 | 3230611 | 111459 | None | Volume3 | Painting on concrete surface Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ of 1 litre for 2 m2. Volume 3 Item no 13.14 page no 123 | Sqm | 88.2 | 88.2 | 10.5 | False | None | None | False | None | False | 926.1 | 0 | 3230612 | 111459 | None | Volume3 | Providing and laying Pitching on slopes laid over prepared filter media including boulder apron laid dry in front of toe of embankment complete as per drawing and Technical specifications Stone/ Boulder Volume 3 Item no 14.4 (A) page no 129 | Cum | 2007.6 | 2007.6 | 17.71 | False | None | None | False | None | False | 35554.596 | 0 | 3230613 | 111459 | None | Volume3 | Providing and laying Filter material underneath pitching in slopes complete as per drawing and Technical specification Volume 3 Item no 14.5 page no 129 | Cum | 3187.8 | 3187.8 | 8.85 | False | None | None | False | None | False | 28212.03 | 0 | 3230614 | 111459 | None | Volume3 | Providing and laying boulders apron on river bed for protection against scour with stone boulders weighing not less than 40 kg each complete as per drawing and Technical specification.Boulder Laid Dry Without Wire Crates. Volume 3 Item no 14.1 (A) page no 129 | Cum | 2007.6 | 2007.6 | 16.14 | False | None | None | False | None | False | 32402.664 | 0 | 3230615 | 111459 | None | Volume1 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening,cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. All other type of structures Volume 1 Item no 2.11(h) page no 18 | t | 82961.55 | 82961.55 | 4.73 | False | None | None | False | None | False | 392408.1315 | 0 | 3230616 | 111459 | None | Volume3 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. .V-1 Item no 2.2.3 Page no 15 M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (The Cost of Form work Included) ( V-3 Item no 2.2.3 Page no 15) | Cum | 6852.38 | 6852.38 | 35.66 | False | None | None | False | None | False | 244355.8708 | 0 | 3230617 | 111459 | None | Volume1 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates V-1 Item no 2.4.3 Page no 16 (The Cost of Form work Included) | Cum | 7983.36 | 7983.36 | 11.28 | False | None | None | False | None | False | 90052.3008 | 0 | 3230618 | 111459 | None | Volume1 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates V-1 Item no 2.4.3 Page no 16 (The Cost of Form work Included) | Cum | 7318.08 | 7318.08 | 26.14 | False | None | None | False | None | False | 191294.6112 | 0 | 3230619 | 111459 | None | Volume1 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates V-1 Item no 2.4.3 Page no 16 (The Cost of Form work Included) | Cum | 9979.2 | 9979.2 | 6.25 | False | None | None | False | None | False | 62370.0 | 0 |
| 1717569406000 | 1 | None | None | Roads | Re Construction of Box Culvert at Chainage 10.200 | 5821626.04 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3230620 | 111460 | None | Volume3 | Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete,wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead By Mechanical Means Cement Concrete Grade M-15 & M-20V-3, P.No 10 I.No 2.8 (ii a) | Cum | 754.95 | 754.95 | 8.8 | False | None | None | False | None | False | 6643.56 | 0 | 3230621 | 111460 | None | Volume1 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m V-1 Item no 1.14.1 Page no 8 | Cum | 107.1 | 107.1 | 656.0 | False | None | None | False | None | False | 70257.6 | 0 | 3230622 | 111460 | None | Volume1 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates V-1 Item no 2.1.3 Page no 15 | Cum | 6288.45 | 6288.45 | 81.22 | False | None | None | False | None | False | 510747.909 | 0 | 3230623 | 111460 | None | Volume3 | Providing and laying of Filter media with granular materials/ stone crushed aggregates satisfying the requirements laid down in clause 2504.2.2. of MoRTH specifications to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and provided over the entire surface behind abutment, wing wall and return wall to the full height compacted to a firm condition complete as per drawing and Technical Specification. Volume 3 Item no 12.4 page no 117 | Cum | 2810.85 | 2810.85 | 123.28 | False | None | None | False | None | False | 346521.588 | 0 | 3230624 | 111460 | None | Volume3 | Curtain wall complete as per drawing and Technical specification Cement concrete Grade M15 Volume 3 Item no 14.8 (b) page no 130 | Cum | 6555.15 | 6555.15 | 83.38 | False | None | None | False | None | False | 546568.407 | 0 | 3230625 | 111460 | None | Volume3 | Painting on concrete surface Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ of 1 litre for 2 m2. Volume 3 Item no 13.14 page no 123 | Sqm | 88.2 | 88.2 | 124.72 | False | None | None | False | None | False | 11000.304 | 0 | 3230626 | 111460 | None | Volume3 | Providing and laying Pitching on slopes laid over prepared filter media including boulder apron laid dry in front of toe of embankment complete as per drawing and Technical specifications Stone/ Boulder Volume 3 Item no 14.4 (A) page no 129 | Cum | 2007.6 | 2007.6 | 48.41 | False | None | None | False | None | False | 97187.916 | 0 | 3230627 | 111460 | None | Volume3 | Providing and laying Filter material underneath pitching in slopes complete as per drawing and Technical specification Volume 3 Item no 14.5 page no 129 | Cum | 3187.8 | 3187.8 | 22.2 | False | None | None | False | None | False | 70769.16 | 0 | 3230628 | 111460 | None | Volume3 | Providing and laying boulders apron on river bed for protection against scour with stone boulders weighing not less than 40 kg each complete as per drawing and Technical specification.Boulder Laid Dry Without Wire Crates. Volume 3 Item no 14.1 (A) page no 129 | Cum | 2007.6 | 2007.6 | 68.09 | False | None | None | False | None | False | 136697.484 | 0 | 3230629 | 111460 | None | Volume3 | PCC M15 Grade leveling course below approach slab complete as per drawing and Technical specification Volume 3 Item no 13.8 page no 121 | Cum | 7151.55 | 7151.55 | 10.6 | False | None | None | False | None | False | 75806.43 | 0 | 3230630 | 111460 | None | Volume3 | Reinforced cement concrete M30 grade for approach slab including reinforcement and formwork complete as per drawing and Technical specification (Batching Plant) Volume 3 Item no 13.9 page no 122 | Cum | 12426.75 | 12426.75 | 21.0 | False | None | None | False | None | False | 260961.75 | 0 | 3230631 | 111460 | None | Volume3 | Asphaltic Plug Joint Providing and laying of asphaltic plug joint to provide for horizontal movement of 25 mm and vertical movement of 2 mm, depth of joint varying from 75 mm to 100 mm, width varying from 500 mm to 750 mm (in traffic direction), covered with a closure plate of 200mm x 6mm of weldable structural steel conforming to IS: 2062, asphaltic plug to consist of polymer modified bitumen binder, carefully selected single size aggregate of 12.5 mm nominal size and a heat resistant foam caulking/ backer rod, all as per approved drawings and specifications. Volume 3 Item no 13.16 page no 124 | m | 1884.75 | 1884.75 | 20.0 | False | None | None | False | None | False | 37695.0 | 0 | 3230632 | 111460 | None | Volume3 | Crash Barrier for Bridges Provision of an Reinforced cement concrete crash barrier at the bridge deck & approaches to bridge structure, constructed withReinforced cement concrete with TMT reinforcement conforming to MORT&H specificatios and as per details given in IRC-5 including dowel bars, 25 mm dia, 450 mm long at expansion joints filled with pre-moulded asphalt filler board etc, keyed to the structure on which it is built and installed as per design given in the enclosure to MOST circular No. RW/NH - 33022/1/94-DO III dated 24 June 1994 as per dimensions in the and approved drawing and at locations directed by the Engineer, all as specified Crash Barrier for Bridges (Height 1100 mm) as per details given IRC-5 (fig-2) (Area 0.298 m2 for 1 m length) Volume 3 Item no 13.13 (B) page no 123 | m | 5113.5 | 5113.5 | 49.4 | False | None | None | False | None | False | 252606.9 | 0 | 3230633 | 111460 | None | Volume3 | Drainage Spouts using 100 mm GI pipe complete as per drawing and Technical specification Volume 3 Item no 13.7 page no 121 | No | 3434.55 | 3434.55 | 6.0 | False | None | None | False | None | False | 20607.3 | 0 | 3230634 | 111460 | None | Volume1 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening,cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. All other type of structures Volume 1 Item no 2.11(h) page no 18 | t | 82961.55 | 82961.55 | 16.89 | False | None | None | False | None | False | 1401220.5795 | 0 | 3230635 | 111460 | None | Volume3 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. .V-1 Item no 2.2.3 Page no 15 M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (The Cost of Form work Included) ( V-3 Item no 2.2.3 Page no 15) | Cum | 6852.38 | 6852.38 | 125.47 | False | None | None | False | None | False | 859768.1186 | 0 | 3230636 | 111460 | None | Volume1 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates V-1 Item no 2.4.3 Page no 16 (The Cost of Form work Included) | Cum | 7983.36 | 7983.36 | 43.1 | False | None | None | False | None | False | 344082.816 | 0 | 3230637 | 111460 | None | Volume1 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates V-1 Item no 2.4.3 Page no 16 (The Cost of Form work Included) | Cum | 7318.08 | 7318.08 | 64.24 | False | None | None | False | None | False | 470113.4592 | 0 | 3230638 | 111460 | None | Volume1 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates V-1 Item no 2.4.3 Page no 16 (The Cost of Form work Included) | Cum | 9979.2 | 9979.2 | 30.3 | False | None | None | False | None | False | 302369.76 | 0 |
| 1717569406000 | 0 | None | None | Roads | Re Construction of Box Culvert at Chainage 11.190 | 1606715.76 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3230639 | 111461 | None | Volume3 | Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete,wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead By Mechanical Means Cement Concrete Grade M-15 & M-20V-3, P.No 10 I.No 2.8 (ii a) | Cum | 754.95 | 754.95 | 1.6 | False | None | None | False | None | False | 1207.92 | 0 | 3230640 | 111461 | None | Volume3 | Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete,wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead By Mechanical means Dismantling Brick / Tile work / rubble masonry / pitching / etc by mechanical means V-3, P.No 10 I.No 2.11 (ii a) | Cum | 189.0 | 189.0 | 10.8 | False | None | None | False | None | False | 2041.2 | 0 | 3230641 | 111461 | None | Volume1 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m V-1 Item no 1.14.1 Page no 8 | Cum | 107.1 | 107.1 | 263.59 | False | None | None | False | None | False | 28230.489 | 0 | 3230642 | 111461 | None | Volume1 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates V-1 Item no 2.1.3 Page no 15 | Cum | 6288.45 | 6288.45 | 25.28 | False | None | None | False | None | False | 158972.016 | 0 | 3230643 | 111461 | None | Volume3 | Providing and laying of Filter media with granular materials/ stone crushed aggregates satisfying the requirements laid down in clause 2504.2.2. of MoRTH specifications to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and provided over the entire surface behind abutment, wing wall and return wall to the full height compacted to a firm condition complete as per drawing and Technical Specification. Volume 3 Item no 12.4 page no 117 | Cum | 2810.85 | 2810.85 | 59.38 | False | None | None | False | None | False | 166908.273 | 0 | 3230644 | 111461 | None | Volume3 | Curtain wall complete as per drawing and Technical specification Cement concrete Grade M15 Volume 3 Item no 14.8 (b) page no 130 | Cum | 6555.15 | 6555.15 | 37.28 | False | None | None | False | None | False | 244375.992 | 0 | 3230645 | 111461 | None | Volume3 | Painting on concrete surface Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ of 1 litre for 2 m2. Volume 3 Item no 13.14 page no 123 | Sqm | 88.2 | 88.2 | 10.5 | False | None | None | False | None | False | 926.1 | 0 | 3230646 | 111461 | None | Volume3 | Providing and laying Pitching on slopes laid over prepared filter media including boulder apron laid dry in front of toe of embankment complete as per drawing and Technical specifications Stone/ Boulder Volume 3 Item no 14.4 (A) page no 129 | Cum | 2007.6 | 2007.6 | 15.37 | False | None | None | False | None | False | 30856.812 | 0 | 3230647 | 111461 | None | Volume3 | Providing and laying Filter material underneath pitching in slopes complete as per drawing and Technical specification Volume 3 Item no 14.5 page no 129 | Cum | 3187.8 | 3187.8 | 7.69 | False | None | None | False | None | False | 24514.182 | 0 | 3230648 | 111461 | None | Volume3 | Providing and laying boulders apron on river bed for protection against scour with stone boulders weighing not less than 40 kg each complete as per drawing and Technical specification.Boulder Laid Dry Without Wire Crates. Volume 3 Item no 14.1 (A) page no 129 | Cum | 2007.6 | 2007.6 | 14.41 | False | None | None | False | None | False | 28929.516 | 0 | 3230649 | 111461 | None | Volume1 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening,cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. All other type of structures Volume 1 Item no 2.11(h) page no 18 | t | 82961.55 | 82961.55 | 4.52 | False | None | None | False | None | False | 374986.206 | 0 | 3230650 | 111461 | None | Volume3 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. .V-1 Item no 2.2.3 Page no 15 M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (The Cost of Form work Included) ( V-3 Item no 2.2.3 Page no 15) | Cum | 6852.38 | 6852.38 | 33.88 | False | None | None | False | None | False | 232158.6344 | 0 | 3230651 | 111461 | None | Volume1 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates V-1 Item no 2.4.3 Page no 16 (The Cost of Form work Included) | Cum | 7983.36 | 7983.36 | 10.72 | False | None | None | False | None | False | 85581.6192 | 0 | 3230652 | 111461 | None | Volume1 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates V-1 Item no 2.4.3 Page no 16 (The Cost of Form work Included) | Cum | 7318.08 | 7318.08 | 22.5 | False | None | None | False | None | False | 164656.8 | 0 | 3230653 | 111461 | None | Volume1 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates V-1 Item no 2.4.3 Page no 16 (The Cost of Form work Included) | Cum | 9979.2 | 9979.2 | 6.25 | False | None | None | False | None | False | 62370.0 | 0 |
| 1717569406000 | 1 | None | None | Roads | Re Construction of Box Culvert at Chainage 11.900 | 3931426.18 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3230654 | 111462 | None | Volume3 | Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete,wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead By Mechanical Means Cement Concrete Grade M-15 & M-20V-3, P.No 10 I.No 2.8 (ii a) | Cum | 754.95 | 754.95 | 1.6 | False | None | None | False | None | False | 1207.92 | 0 | 3230655 | 111462 | None | Volume3 | Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete,wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead By Mechanical means Dismantling Brick / Tile work / rubble masonry / pitching / etc by mechanical means V-3, P.No 10 I.No 2.11 (ii a) | Cum | 189.0 | 189.0 | 10.8 | False | None | None | False | None | False | 2041.2 | 0 | 3230656 | 111462 | None | Volume1 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m V-1 Item no 1.14.1 Page no 8 | Cum | 107.1 | 107.1 | 515.13 | False | None | None | False | None | False | 55170.423 | 0 | 3230657 | 111462 | None | Volume1 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates V-1 Item no 2.1.3 Page no 15 | Cum | 6288.45 | 6288.45 | 54.96 | False | None | None | False | None | False | 345613.212 | 0 | 3230658 | 111462 | None | Volume3 | Providing and laying of Filter media with granular materials/ stone crushed aggregates satisfying the requirements laid down in clause 2504.2.2. of MoRTH specifications to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and provided over the entire surface behind abutment, wing wall and return wall to the full height compacted to a firm condition complete as per drawing and Technical Specification. Volume 3 Item no 12.4 page no 117 | Cum | 2810.85 | 2810.85 | 133.08 | False | None | None | False | None | False | 374067.918 | 0 | 3230659 | 111462 | None | Volume3 | Curtain wall complete as per drawing and Technical specification Cement concrete Grade M15 Volume 3 Item no 14.8 (b) page no 130 | Cum | 6555.15 | 6555.15 | 61.7 | False | None | None | False | None | False | 404452.755 | 0 | 3230660 | 111462 | None | Volume3 | Painting on concrete surface Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ of 1 litre for 2 m2. Volume 3 Item no 13.14 page no 123 | Sqm | 88.2 | 88.2 | 15.12 | False | None | None | False | None | False | 1333.584 | 0 | 3230661 | 111462 | None | Volume3 | Providing and laying Pitching on slopes laid over prepared filter media including boulder apron laid dry in front of toe of embankment complete as per drawing and Technical specifications Stone/ Boulder Volume 3 Item no 14.4 (A) page no 129 | Cum | 2007.6 | 2007.6 | 44.73 | False | None | None | False | None | False | 89799.948 | 0 | 3230662 | 111462 | None | Volume3 | Providing and laying Filter material underneath pitching in slopes complete as per drawing and Technical specification Volume 3 Item no 14.5 page no 129 | Cum | 3187.8 | 3187.8 | 22.37 | False | None | None | False | None | False | 71311.086 | 0 | 3230663 | 111462 | None | Volume3 | Providing and laying boulders apron on river bed for protection against scour with stone boulders weighing not less than 40 kg each complete as per drawing and Technical specification.Boulder Laid Dry Without Wire Crates. Volume 3 Item no 14.1 (A) page no 129 | Cum | 2007.6 | 2007.6 | 38.68 | False | None | None | False | None | False | 77653.968 | 0 | 3230664 | 111462 | None | Volume1 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening,cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. All other type of structures Volume 1 Item no 2.11(h) page no 18 | t | 82961.55 | 82961.55 | 12.05 | False | None | None | False | None | False | 999686.6775 | 0 | 3230665 | 111462 | None | Volume3 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. .V-1 Item no 2.2.3 Page no 15 M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (The Cost of Form work Included) ( V-3 Item no 2.2.3 Page no 15) | Cum | 6852.38 | 6852.38 | 99.6 | False | None | None | False | None | False | 682497.048 | 0 | 3230666 | 111462 | None | Volume1 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates V-1 Item no 2.4.3 Page no 16 (The Cost of Form work Included) | Cum | 7983.36 | 7983.36 | 25.84 | False | None | None | False | None | False | 206290.0224 | 0 | 3230667 | 111462 | None | Volume1 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates V-1 Item no 2.4.3 Page no 16 (The Cost of Form work Included) | Cum | 7318.08 | 7318.08 | 67.09 | False | None | None | False | None | False | 490969.9872 | 0 | 3230668 | 111462 | None | Volume1 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates V-1 Item no 2.4.3 Page no 16 (The Cost of Form work Included) | Cum | 9979.2 | 9979.2 | 12.96 | False | None | None | False | None | False | 129330.432 | 0 |
| 1717569406000 | 1 | None | None | Roads | Utility Shifting - Electrical Pole Shifting and Re installation | 8801542.79 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3230669 | 111463 | None | Volume6 | Supply and errection of Pre-Stressed Tubular Spun Pole - 11 Mtr Long 500 Kg WL(Dwg No. BESCOM/GM/QS&S/45 Dtd 24.11.2018) as per IS-13158 1991 including Digging of Pit 2.5 Mtr depth for erection of 11 Mtr long Tubular Spun Pole as per approved Drawing for Ordinary soil and Erection of 11 Mtr long Concrete Spun Pole in a pit of 2.5 Mtr depth (Mechnised Labour) (Item no 1.07 page 3 of 81 and Item no 1.5.1 and 2.05 page 43 & 44 of 81 Volume-6) | No | 23258.55 | 23258.55 | 4.0 | False | None | None | False | None | False | 93034.2 | 0 | 3230670 | 111463 | None | Volume6 | Supply & Erection of RCC Pole - 9 Mtr Long, 145 Kg WL (Dwg No.BESCOM/GM/QS&S/02 Dtd 24.11.2018) as per IS-785 including Digging of Pit 1.8 Mtr depth for errection of 9 to 10 Mtr Long Steel/RCC/PSCC supports as per approved
Drawing for Ordinary Soil and Erection of RCC/PSCC Pole of 9 to 10 Mtr long in a pit of 1.8 Mtr depth (Item no 1.10 page 3 of 81 and Item no 1.1.1 and 2.02 page 43 & 44 of 81 Volume-6) | No | 9258.9 | 9258.9 | 38.0 | False | None | None | False | None | False | 351838.2 | 0 | 3230671 | 111463 | None | Volume6 | Supply & Erection of PSCC Pole - 9 Mtr Long, 200 Kg WL (Dwg No.BESCOM/GM/QS&S/50 Dtd 24.11.2018) as per REC Standards including Digging of Pit 1.8 Mtr depth for errection of 9 to 10 Mtr Long Steel/RCC/PSCC supports as per approved
Drawing for Ordinary Soil and Erection of RCC/PSCC Pole of 9 to 10 Mtr long in a pit of 1.8 Mtr depth (Item no 1.06 page 3 of 81 and Item no 1.1.1 and 2.02 page 43 & 44 of 81 Volume-6) | No | 6238.05 | 6238.05 | 158.0 | False | None | None | False | None | False | 985611.9 | 0 | 3230672 | 111463 | None | Volume6 | Supply & Erection of Double Pole Structure complete including 5 Kg, 8 SWG GI Wire for Structure Grounding of 9M PSCC Pole with 300 Kg WL (C,D.S Pg No 339/635 I .No 4.(C)) | No | 23385.6 | 23385.6 | 7.0 | False | None | None | False | None | False | 163699.2 | 0 | 3230673 | 111463 | None | Volume6 | Supply & Fixing 11 kV, 200 Amps Single Break GOS (DwgNo.BESCOM/GM/QS&S/23 Dtd 24.11.2018) (Item no 24.01 page 11 of 81 and Item no 13.02 48 of 81 Volume-6) | Set | 11081.7 | 11081.7 | 4.0 | False | None | None | False | None | False | 44326.8 | 0 | 3230674 | 111463 | None | Volume6 | Supply of H - Frame Set for fixing 11 kV, 200 Amps Single Break
GOS - (For DP structure for providing New GOS for sectionalisation) - MS and Erection of H-Frame (Item no 24.06 page 11 of 81 and Item no 2.09 44 of 81 Volume-6) | Set | 4887.75 | 4887.75 | 4.0 | False | None | None | False | None | False | 19551.0 | 0 | 3230675 | 111463 | None | Volume6 | Supply & providing of 11 kV, Horizontal Cross Arm with HT Single Top supports, clamps, bolts, nuts & washers - MS For RCC Pole (C,D.S Pg No 341/635 I .No 9.(c)) | Set | 963.9 | 963.9 | 251.0 | False | None | None | False | None | False | 241938.9 | 0 | 3230676 | 111463 | None | Volume6 | Supply & Providing of 11 kV, 45 kN Polymeric Insulator (Item no 6.10 page no 5 of 81) | No | 195.3 | 195.3 | 156.0 | False | None | None | False | None | False | 30466.8 | 0 | 3230677 | 111463 | None | Volume6 | Supply & Providing of 11 kV, 5 kN Composite/Polymeric Pin Insulator (24 mm dia FRP Rod) (Item no 6.06 page no 5 of 81) | No | 215.25 | 215.25 | 503.0 | False | None | None | False | None | False | 108270.75 | 0 | 3230678 | 111463 | None | Volume6 | Supply & Providing Guy set with No. 15 Strain Insulator & Concreting materials as per Dwg No. BESCOM/GM/CP/7 Dt: 24.10.07 (C,D.S Pg No 344/635 I .No 24.(b)) | Set | 1851.15 | 1851.15 | 15.0 | False | None | None | False | None | False | 27767.25 | 0 | 3230679 | 111463 | None | Volume6 | Supply & stringing of Rabbit ACSR
(6/3.35 mm Al Plus 1/3.35 mm St), Std Wt: 214 Kg/KM and Stringing of Conductor for Rabbit ACSR (Item no 7.02 page no 5 of 81 and 6.02 page no 46 of 81) | Km | 53124.75 | 53124.75 | 5.65 | False | None | None | False | None | False | 300154.8375 | 0 | 3230680 | 111463 | None | Volume6 | Supply of Spiral Earth Electrode and Providing Spiral Earth Electrode type earthing (without charcoal, salt etc.,) (Item no 2.16 page no 4 of 81 and 2.08 page no 44 of 81) | No | 348.6 | 348.6 | 214.0 | False | None | None | False | None | False | 74600.4 | 0 | 3230681 | 111463 | None | Volume6 | Guarding between HT & LT Line ( Guarding Material (Rs. 93/Mtr))(C,D.S 5 Pg No 351/635 I .No 16.(a)) | Mtr | 6776.7 | 6776.7 | 6.0 | False | None | None | False | None | False | 40660.2 | 0 | 3230682 | 111463 | None | Volume6 | Supply & Erection of DP Transformer Structure using PSCC Pole - 9
Mtr Long, 300 Kg WL (Including Cost of Poles) (C,D.S Pg No 416/635 Sl.No 1) | Set | 36383.55 | 36383.55 | 7.0 | False | None | None | False | None | False | 254684.85 | 0 | 3230683 | 111463 | None | Volume6 | Supply & Providing of 11 kV, 45 kN Polymeric Insulator (Item no 6.1 page no 5 of 81) | No | 195.3 | 195.3 | 21.0 | False | None | None | False | None | False | 4101.3 | 0 | 3230684 | 111463 | None | Volume6 | Supply & Providing of 11 kV, 5 kN Composite/Polymeric Pin Insulator (24 mm dia FRP Rod) (Item no 6.06 page no 5 of 81) | No | 215.25 | 215.25 | 21.0 | False | None | None | False | None | False | 4520.25 | 0 | 3230685 | 111463 | None | Volume6 | Supply & providing of GI Grounding pipe, B - Class, 42 mm dia, 2.5 M long, 3.2 mm thick with bolts nuts, GI Strips and washers complete Minimum Weight of GI Pipe: 7.3 Kgs (C,D.S Pg No 344/635 I .No 25.(a)) | No | 2811.9 | 2811.9 | 21.0 | False | None | None | False | None | False | 59049.9 | 0 | 3230686 | 111463 | None | Volume6 | Supply & providing of GI wire 8SWG (V-6, Sl.No.61, P.No. 5 of 81, It.No.8.02, Material Code 281008) | Kg | 78.79 | 78.79 | 35.0 | False | None | None | False | None | False | 2757.65 | 0 | 3230687 | 111463 | None | Volume6 | Supply & providing of 7/10 SWG Guy Wire (7/3.251 mm Dia), Std Wt: 680 Kg/KM (Item no 8.01 page no 5 of 81) | Kg | 81.09 | 81.09 | 70.0 | False | None | None | False | None | False | 5676.3 | 0 | 3230688 | 111463 | None | Volume6 | Supply & providing of 9 kV, 5 kA Lightning Arrester Metal Oxide Ceramic typewith GROUND DISCONNECTOR
(Dwg No. BESCOM/GM/QS&S/26 Dtd 24.10.2007) and Fixing of 3 Nos Lightning Arrestor including wiring (Item no 19.01 page 9 of 81 and Item no 13.06 48 of 81 Volume-6) | Set | 1090.95 | 1090.95 | 21.0 | False | None | None | False | None | False | 22909.95 | 0 | 3230689 | 111463 | None | Volume6 | Supply 11 kV, HG Fuse Unit with Solid CoreInsulator(DwgNo.BESCOM/GM/QS&S/21 Dtd 24.11.2018) and providing of 11 kV, Solid Core Type HG Fuse Unit (Item no 20.1 page no 9 of 81 and C.D.S-24 SI NO 15 Pg No 371/635) | Set | 1371.3 | 1371.3 | 7.0 | False | None | None | False | None | False | 9599.1 | 0 | 3230690 | 111463 | None | Volume6 | Supply & Fixing 11 kV, 200 Amps Single Break GOS
(Dwg No. BESCOM/GM/QS&S/23 Dtd 24.11.2018) Fixing of GOS including wiring (11 kV Single Break 200
Amps) (Item no 24.01 page 11 of 81 and Item no 13.02 48 of 81 Volume-6) | Set | 11081.7 | 11081.7 | 7.0 | False | None | None | False | None | False | 77571.9 | 0 | 3230691 | 111463 | None | Volume6 | Supply of H - Frame Set for fixing 11 kV, 200 Amps Single Break
GOS - (For DP structure for providing New GOS for sectionalisation) - MS and Erection of H-Frame (Item no 24.06 page 11 of 81 and Item no 2.09 44 of 81 Volume-6) | Set | 4887.75 | 4887.75 | 7.0 | False | None | None | False | None | False | 34214.25 | 0 | 3230692 | 111463 | None | Volume6 | Supply of Caution/Danger Board and Fixing Danger Board (Item no 68.17 page 32 of 81 and Item no 5.15 45 of 81 Volume-6) | No | 241.5 | 241.5 | 7.0 | False | None | None | False | None | False | 1690.5 | 0 | 3230693 | 111463 | None | Volume6 | Supply & Fixing of Anticlimbing Device, GI GI Barbed wire (12 Mtr/Kg) and Fixing of GI Barbed Wire (12 Mtr) (Item no 4.02 page 4 of 81 and Item no 5.09 45 of 81 Volume-6) | Each | 137.55 | 137.55 | 7.0 | False | None | None | False | None | False | 962.85 | 0 | 3230694 | 111463 | None | Volume6 | Supply & providing Transparent Alkathine tube 19mm dia, 2mm thick in coils of 30 mtrs (V-6, Sl.No.349, P.No. 23 of 81, It.No.52.01, Material Code 821900) | Coil | 589.42 | 589.42 | 7.0 | False | None | None | False | None | False | 4125.94 | 0 | 3230695 | 111463 | None | Volume6 | Supply & providing LT Metering box with CTs and necessary wiring for housing ETV Meter (Please see CDS -39) (C,D.S Pg No 370/635 I .No 14.(c)) | No | 7556.85 | 7556.85 | 7.0 | False | None | None | False | None | False | 52897.95 | 0 | 3230696 | 111463 | None | Volume6 | Supplying and providing 4 Pin Cross Arm with clamps, bolts, nuts and washers for
guarding (C,D.S Pg No 351/635 I .No 16.(b) ) | Set | 609.0 | 609.0 | 80.0 | False | None | None | False | None | False | 48720.0 | 0 | 3230697 | 111463 | None | Volume6 | Supplying and providing LT 2 Pin Cross Arm with clamps, bolts, nuts for PSCC
Pole - 9 Mtr Long, 200 Kg WL (C,D.S Pg No 356/635 I .No 6) | Set | 444.15 | 444.15 | 66.0 | False | None | None | False | None | False | 29313.9 | 0 | 3230698 | 111463 | None | Volume6 | Supplying and providing 11 kV GI Pin for 11 kV Ceramic Shell Insulator (Item no 6.02 page no 5 of 81) | No | 69.3 | 69.3 | 350.0 | False | None | None | False | None | False | 24255.0 | 0 | 3230699 | 111463 | None | Volume6 | Supplying and providing No.8 strain insulator (Item no 6.07 page no 5 of 81) | No | 28.35 | 28.35 | 50.0 | False | None | None | False | None | False | 1417.5 | 0 | 3230700 | 111463 | None | Volume6 | Supply & stringing of Rabbit ACSR
(6/3.35 mm Al Plus 1/3.35 mm St), Std Wt: 214 Kg/KM and Stringing of Conductor for Rabbit ACSR (Item no 7.02 page no 5 of 81 and 6.02 page no 46 of 81) | Km | 53124.75 | 53124.75 | 2.1 | False | None | None | False | None | False | 111561.975 | 0 | 3230701 | 111463 | None | Volume6 | Guy Set Complete with No. 8 Strain Insulator (Including Material Labour Charge) (V-6, (C,D.S Pg No 344/635 I .No 24 at ) Material Code 279650, 279140) | Set | 1851.15 | 1851.15 | 6.0 | False | None | None | False | None | False | 11106.9 | 0 | 3230702 | 111463 | None | Volume6 | Labour for Guy concreting with Boulders, Mud & Sand (300x300x450 mm)As per Drawing No. BESCOM/GM/CP/7 Dt: 24.10.07 (C,D.S Pg No 345/635 I .No 26.(g) | Each | 262.5 | 262.5 | 6.0 | False | None | None | False | None | False | 1575.0 | 0 | 3230703 | 111463 | None | Volume6 | Loading and unloading of Pole (loading of Pole to vehicles at stores and unloading at
workspot) NOTE:- Consolidated amount for both loading and unloading 9 Mtr RCC/PSCC Pole (C,D.S Pg No 480/635 I .No 17.05.2) | No | 149.1 | 149.1 | 224.0 | False | None | None | False | None | False | 33398.4 | 0 | 3230704 | 111463 | None | Volume6 | Releasing of RCC Pole - 9 M Long, 145 Kg WL (CDS I.No 1 (b) Pg No 339 of 635 ) | No | 1646.19 | 1646.19 | 14.0 | False | None | None | False | None | False | 23046.66 | 0 | 3230705 | 111463 | None | Volume6 | Releasing and Re-erection of c) PSCC Pole - 9 M Long, 300 Kg WL (CDS I No 2 (c) Pg No 339 of 635 ) | No | 3475.29 | 3475.29 | 100.0 | False | None | None | False | None | False | 347529.0 | 0 | 3230706 | 111463 | None | Volume6 | Releasing of Double Pole Structure complete including 5 Kg, 8 SWG GI Wire for Structure Grounding Of 9M PSCC Pole with 300 Kg WL (CDS I.No 4 (c) Pg No 339 of 635 ) | Set | 5095.44 | 5095.44 | 7.0 | False | None | None | False | None | False | 35668.08 | 0 | 3230707 | 111463 | None | Volume6 | Releasing & Refixing of GOS including wiring (11 kV Single Break 200
Amps) ( I.No 13.02 Pg No 48 of 81 ) | Set | 2202.48 | 2202.48 | 3.0 | False | None | None | False | None | False | 6607.44 | 0 | 3230708 | 111463 | None | Volume6 | Releasing & Refixing of H Frame.( I.No 2.09 Pg No 44 of 81 ) | No | 644.39 | 644.39 | 3.0 | False | None | None | False | None | False | 1933.17 | 0 | 3230709 | 111463 | None | Volume6 | Releasing and Restringing of Rabbit ACSR ( I.No 6.02 Pg No 46 of 81 ) | Per Km | 8700.2 | 8700.2 | 28.95 | False | None | None | False | None | False | 251870.79 | 0 | 3230710 | 111463 | None | Volume6 | Relasing of Double Pole Transformer Structure using 9 Mtr Long RCC (145 Kg WL)/PSCC (300 Kg WL) Pole including fixing of Structure Materials, Erection of Poles etc complete for mounting of Transformer as per approved drawing For 25/63/100 kVA ( I No 3.01 Pg No 44 of 81 ) | Set | 5503.05 | 5503.05 | 6.3 | False | None | None | False | None | False | 34669.215 | 0 | 3230711 | 111463 | None | Volume6 | Releasing and erection of 25kva Transformer (V-6, Sl.No.72, P.No. 46 of 81, It.No.8.01) | No | 1252.65 | 1252.65 | 5.7 | False | None | None | False | None | False | 7140.105 | 0 | 3230712 | 111463 | None | Volume6 | Releasing and erection of 63kva Transformer (V-6, Sl.No.72, P.No. 46 of 81, It.No.8.01) | No | 1252.65 | 1252.65 | 3.8 | False | None | None | False | None | False | 4760.07 | 0 | 3230713 | 111463 | None | Volume6 | Releasing and erection of 100kva Transformer (V-6, Sl.No.73, P.No. 46 of 81, It.No.8.02) | No | 1669.5 | 1669.5 | 3.8 | False | None | None | False | None | False | 6344.1 | 0 | 3230714 | 111463 | None | Volume6 | Supply & providing of LT wiring (from DTC to LT line) (Including Material Labour Charge) (V-6, (C,D.S-24, Pg No 370/635 Material Code 613050) | No | 1594.95 | 1594.95 | 14.0 | False | None | None | False | None | False | 22329.3 | 0 | 3230715 | 111463 | None | Volume6 | Aluminium Wire 50Sq.mm (Including Material Labour Charge) (V-6, (C,D.S-24, Pg No 370/635 Material Code 613050) | Mtr | 67.4 | 67.4 | 350.0 | False | None | None | False | None | False | 23590.0 | 0 | 3230716 | 111463 | None | Volume6 | Supply & providing of LT wiring (from DTC to LT line Through metering Box and LT Protection Kit) Single Circuit ii) Heavy Duty Long Barrel Copper Lug 50 Sqmm (C.D.S-24 I.No.14b (ii) Pg.No 370 of 635) (Material) | No | 60.9 | 60.9 | 56.0 | False | None | None | False | None | False | 3410.4 | 0 | 3230717 | 111463 | None | Volume6 | Supply & providing of LT wiring (from DTC to LT line Through metering Box and LT Protection Kit) Single Circuit iii) PG Clamp Rabbit to 50 Sqmm (C.D.S-24 I.No.14 b (iii) Pg No. 370 of 635) (Material) | No | 107.1 | 107.1 | 56.0 | False | None | None | False | None | False | 5997.6 | 0 | 3230718 | 111463 | None | Volume6 | Supply & providing of LT wiring (from DTC to LT line Through metering Box and LT Protection Kit) Single Circuit iv) Spacer for DTC wiring (C.D.S-24 I.No.14 b (iv) Pg No. 370 of 635) (Material) | No | 44.1 | 44.1 | 112.0 | False | None | None | False | None | False | 4939.2 | 0 | 3230719 | 111463 | None | Volume6 | Supply & providing of LT wiring (from DTC to LT line Through metering Box and LT Protection Kit) Single Circuit v) Fish Plate with necessary clamps, bolts & nuts etc complete (Galvanised) (C.D.S-24 I.No.14 b (iv) Pg No. 370 of 635) (Material) | No | 277.2 | 277.2 | 28.0 | False | None | None | False | None | False | 7761.6 | 0 | 3230720 | 111463 | None | Volume6 | Jungle clearing (V-6, Sl.No.95, P.No. 62 of 81, It.No.18.02) | Km | 4354.35 | 4354.35 | 10.1 | False | None | None | False | None | False | 43978.935 | 0 | 3230721 | 111463 | None | Volume6 | Releasing of LT 4 Pin cross arms (V-6, Sl.No.50, P.No. 46 of 81, It.No.7.06) | No | 168.0 | 168.0 | 36.0 | False | None | None | False | None | False | 6048.0 | 0 | 3230722 | 111463 | None | Volume6 | Releasing and Refixing of Service mains (V-6, Sl.No.71, P.No. 46 of 81, It.No.7.06) | No | 94.5 | 94.5 | 123.5 | False | None | None | False | None | False | 11670.75 | 0 | 3230723 | 111463 | None | Volume6 | Fabricating, supplying and erection of …Mtrs long hot dip Galvanized Conical pole with BSEN 10025 grade S355JO steel plate for shaft, IS 2062 for base plate with door opening arrangements, including suitable boards, Bakelite sheet and MCBs as per IS specifications suitable to withstand the wind speed of 47 m/sec for …….Mtrs pole in single section and single joint welded as per IS 9595/IS 10178AWS having dimensions bottom …..mm, top….mm with 3mm thick, suitable base plate and 4Nos of ..... long J bolts along with template and the pole shall be hot dip galvanized in single dipping with not less than 65micron as per ASTM-A123 and 153 etc.,(excluding foundation) as per drawing appended. 9 meters - Top 75mm and bottom 165 mm dia B lore elect SR 22-23 item no 4.4.7 PN:6 | Each | 21525.0 | 21525.0 | 96.0 | False | None | None | False | None | False | 2066400.0 | 0 | 3230724 | 111463 | None | Volume6 | Supply and Installation / Fixing / Provision of Pole box with HRC Fuse / MCB provision and suitable connector / terminal for 3 Ph / 1 Ph connections with Loop-In & Loop- Out terminals for 10 Sqmm / 25 Sqmm 3.5 C Al/Ar / Cu/ Ar Cable and branch out 2.5 Sqmm 2 core Al/Cu PVC Insulated cable, enclosed in a Thermoplastic, Polystyrene enclosure, which should be shock proof, safe, IP65(Weather Proof), rust proof, dust proof, water proof having Internally Embedded Gasket with provision for cable entry through IP65 Thermoplastic, polyamide glands and/or grommets. 200mmx200mmx98mm B lore elect SR 23-24 item no 5.43.1 PN:20 | Each | 2415.0 | 2415.0 | 96.0 | False | None | None | False | None | False | 231840.0 | 0 | 3230725 | 111463 | None | Volume6 | Supplying, and fixing of Hot dip Galvanized M.S.Bracketsuitable for out door luminaries and mounted on Octagonal pole using necessary bolts, nuts etc., complete Single Arm Bracket with 1500mm Standard 40/50MM dia B lore elect SR 23-24 item no 4.6.2 PN:13 | Each | 2205.0 | 2205.0 | 96.0 | False | None | None | False | None | False | 211680.0 | 0 | 3230726 | 111463 | None | Volume6 | Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr at Lumen Maintenance of 70percent, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED Efficiency130lm/w, nominal CRI 75.Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentione above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Streetlight 120watts B lore elect SR 23-24 item no 11.8.5 PN:46 | Each | 10563.0 | 10563.0 | 96.0 | False | None | None | False | None | False | 1014048.0 | 0 | 3230727 | 111463 | None | Volume6 | Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS:8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100Volts as per IS-694:1990 3cx 2.5mm sqr SR 23-24 item no 2.5.8 PN:6 | Mtr | 118.65 | 118.65 | 960.0 | False | None | None | False | None | False | 113904.0 | 0 | 3230728 | 111463 | None | Volume6 | 1.1 KV XLPE or Heat resistant PVC insulated, PVC insulated PVC Exutured Inner seath armoured LTUG Cable as per IS -1554 (Part-1) or IS-7098 Part-1,Armouting strip thickness and resistivity as per IS -3975 16 Sqmm, 4 Core, (11 GI Strips - 4x0.8 mm) Escom SR (2023-24 P.No.13, F-201, It No 32.05) | Km | 148934.1 | 148934.1 | 1.58 | False | None | None | False | None | False | 235315.878 | 0 | 3230729 | 111463 | None | Volume6 | 1.1 KV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner seath armoured LTUG Cable as per IS -1554 (Part-1) or IS-7098 Part-1,Armouting strip thickness and resistivity as per IS -3975 25 Sqmm, 3.5 Core, (12 GI Strips - 4 x 0.8 mm) Escom SR (2023-24 P.No.13,J-203, It No 32.07) | Km | 146526.45 | 146526.45 | 0.1 | False | None | None | False | None | False | 14652.645 | 0 | 3230730 | 111463 | None | Volume6 | Supplying, fixing , wiring, earth electrode for grounding conduits, IC cutouts and other equipment's on the meter board using 40mm dia 2.90 mm thick GI pipe 2.5m long buried in a pit. The pit should be filled with equal proportion of salt and charcoal 150 mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc, is to be established through GI Wire of size as per ISI specification 7.3.3 of IS 732 using 12mm dia bolts, nuts, washers and check nuts etc, the pipe shall have 16 through holes of 12mm dia Escom SR (2023-24 P.No.54, It No 12.56) | No | 3685.5 | 3685.5 | 2.0 | False | None | None | False | None | False | 7371.0 | 0 | 3230731 | 111463 | None | Volume6 | Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH, KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5 accuracy. SR 23-24 item no 5.33 PN:19 | Each | 9780.75 | 9780.75 | 3.0 | False | None | None | False | None | False | 29342.25 | 0 | 3230732 | 111463 | None | Volume6 | Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440v A.C. 50 Hz 12/24v D.C. elect SR 23-24 item no 5.38 PN:19 | Each | 540.75 | 540.75 | 8.0 | False | None | None | False | None | False | 4326.0 | 0 | 3230733 | 111463 | None | Volume6 | Supplying and fixing Microprocessor based Electronic timer (without contactor, Din Mounting using necessary bolts, nuts and washers etc) 3.120sec setting.elect SR 23-24 item no 5.47 PN:21 | Each | 2430.75 | 2430.75 | 3.0 | False | None | None | False | None | False | 7292.25 | 0 | 3230734 | 111463 | None | Volume6 | Supply and fixing of 3pole power contactor with NO/NC contacts on existing wood/panel board using necessary bolts, nuts, washers and wiring etc., complete with AC-3 Rating and as per IS-13947. elect SR 23-24 item no 5.13.2 PN:16 | Each | 2370.9 | 2370.9 | 3.0 | False | None | None | False | None | False | 7112.7 | 0 | 3230735 | 111463 | None | Volume6 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and C Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 ATPN(2023-24 P-17, I.No-5.18.7) | Each | 1802.85 | 1802.85 | 15.0 | False | None | None | False | None | False | 27042.75 | 0 | 3230736 | 111463 | None | Volume6 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and C Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 40 Amps TPN B lore elect SR 23-24 item no 5.18.8 PN:17) | Each | 3196.2 | 3196.2 | 3.0 | False | None | None | False | None | False | 9588.6 | 0 | 3230737 | 111463 | None | Volume6 | Supplying and fixing angle iron frame work fabricated out of M.S. angle iron. and M.S. flat … with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint.40x40x6mm elect SR 23-24 item no 5.41.1 PN:20 | Mtr | 320.25 | 320.25 | 8.0 | False | None | None | False | None | False | 2562.0 | 0 | 3230738 | 111463 | None | Volume6 | Supplying amps rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40.6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete.100A 4x30x6mm Aluminiym Strips elect SR 23-24 item no 5.40.1 PN:20 | Mtr | 2588.25 | 2588.25 | 8.0 | False | None | None | False | None | False | 20706.0 | 0 | 3230739 | 111463 | None | Volume6 | Fabricating, supplying and erection of …Mtrs long hot dip Galvanized Conical pole with BSEN 10025 grade S355JO steel plate for shaft, IS 2062 for base plate with door opening arrangements, including suitable boards, Bakelite sheet and MCBs as per IS specifications suitable to withstand the wind speed of 47 m/sec for …….Mtrs pole in single section and single joint welded as per IS 9595/IS 10178AWS having dimensions bottom ….mm, top….mm with 3mm thick, suitable base plate and 4Nos of . long J bolts along with template and the pole shall be hot dip galvanized in single dipping with not less than 65micron as per ASTM-A123 and 153 etc.,(excluding foundation) as per drawing appended. 9 meters - Top 75mm and bottom 165 mm dia B lore elect SR 22-23 item no 4.4.7 PN:12 | Nos | 19372.5 | 19372.5 | 25.0 | False | None | None | False | None | False | 484312.5 | 0 | 3230740 | 111463 | None | Volume6 | Supply and Installation / Fixing / Provision of Pole box with HRC Fuse / MCB provision and suitable connector / terminal for 3 Ph / 1 Ph connections with Loop-In & Loop- Out terminals for 10 Sqmm / 25 Sqmm 3.5 C Al/Ar / Cu/ Ar Cable and branch out 2.5 Sqmm 2 core Al/Cu PVC Insulated cable, enclosed in a Thermoplastic, Polystyrene enclosure, which should be shock proof, safe, IP65(Weather Proof), rust proof, dust proof, water proof having Internally Embedded Gasket with provision for cable entry through IP65 Thermoplastic, polyamide glands and/or grommets. 200mmx200mmx98mm B lore elect SR 23-24 item no 5.43.1 PN:20 | Each | 2173.5 | 2173.5 | 25.0 | False | None | None | False | None | False | 54337.5 | 0 | 3230741 | 111463 | None | Volume6 | Supplying,andfixingofHotdipGalvanizedM.S.BracketsuitableforoutdoorluminariesandmountedonOctagonalpoleusingnecessarybolts, nuts etc., complete Double Arm Bracket with 1500 mm Standard 40/50 mm dia B lore elect SR 23-24 item no 4.6.5 PN:13 | Each | 3118.5 | 3118.5 | 25.0 | False | None | None | False | None | False | 77962.5 | 0 | 3230742 | 111463 | None | Volume6 | Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS:8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100Volts as per IS-694:1990 Each pole requires 20 metres of 3Cx2.5sqmm cable 3C X 2.5Sq.mm B lore elect SR 19-20 item no 2.5.8 PN:6 | Mtr | 106.79 | 106.79 | 500.0 | False | None | None | False | None | False | 53395.0 | 0 | 3230743 | 111463 | None | Volume6 | Fabricating supplying and mounting MS box made out …SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. The area of MS sheet required for construction of Street light panel sized 600x600x400mm 16SWG B lore elect SR 23-24 item no 5.42.2 PN:20 | Sq | 0.41 | 0.41 | 2500.0 | False | None | None | False | None | False | 1025.0 | 0 |
| 1717569406000 | 0 | None | None | Roads | Utility Shifting - Water Line | 2432178.0 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3230744 | 111464 | None | Volume1 | Earth work excavation for pipeline trenches in all kinds of soils by mechanical means as per drawing and technical specifications, including setting out,construction of shoring, strutting, barricading, caution lights, bracing, using sight rails & bonding rods at every 100 mm wherever necessary as directed,removal of stumps and other deleterious matter, dressing of sides and levelling the bottom of trench to the extent required , utilising the available excavated earth locally for the work etc., and all other appurtenances complete in the following strata.All kinds of soils. Depth upto 1.50 m COMMON SR 2023-24,Vol I, Pg.No. 10 Sl.No.1.17 | Cum | 275.1 | 275.1 | 1680.0 | False | None | None | False | None | False | 462168.0 | 0 | 3230745 | 111464 | None | Common SR V | Providing, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc. complete. NOTE: Upto 110mm dia Coil shall be used.For :HDPE PE 80 PN 6.0) (HDPE Grade PE100-PN6.0,75mm dia) Common SR Vol V 2023-24, Pg.No. 102 It.No.9.10.2 | m | 223.65 | 223.65 | 7000.0 | False | None | None | False | None | False | 1565550.0 | 0 | 3230746 | 111464 | None | Common SR V | Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark.(For 80 mm dia GM (Copper alloy) Gate valves) | Each | 1997.1 | 1997.1 | 8.0 | False | None | None | False | None | False | 15976.8 | 0 | 3230747 | 111464 | None | Common SR V | Providing and installation of Class SN8 Double Wall Corrugated HDPE Specials outer wall corrugated and inner wall smooth piping system in accordance with IS 16098 part 2 and conveying to work site and
lowering into trenches, laying true to line and level and perfect linking at joints with the help of two "O" rings and a coupler of suitable size,including loading and unloading at both destination and cutting of pipes where ever necessary including jointing with all labour, all lead and lift including encasing the Specials around to a depth of not less than 15 cm with screened soft soil available from the excavated soil. The testing
commissioning including necessary hydraulic test to the required pressure as per ISS shall be done the contractor shall have to make his own arrangement for procuring water for testing etc. complete.(75 MM ELECTRO FUSION COUPLER) Common SR Vol V 2023-24, Item No. 9.17.28 Pg.No. 108 | Each | 187.95 | 187.95 | 70.0 | False | None | None | False | None | False | 13156.5 | 0 | 3230748 | 111464 | None | Common SR V | Providing and installation of Class SN8 Double Wall Corrugated HDPE Specials outer wall corrugated and inner wall smooth piping system in accordance with IS 16098 part 2 and conveying to work site and
lowering into trenches, laying true to line and level and perfect linking at joints with the help of two "O" rings and a coupler of suitable size,including loading and unloading at both destination and cutting of pipes where ever necessary including jointing with all labour, all lead and lift including encasing the Specials around to a depth of not less than 15 cm with screened soft soil available from the excavated soil. The testing
commissioning including necessary hydraulic test to the required pressure as per ISS shall be done the contractor shall have to make his own arrangement for procuring water for testing etc. complete.(75 MM ELECTRO FUSION ELBOW) (Common SR Vol V 2023-24, Item No. 9.17.34 Pg.No. 108) | Each | 302.4 | 302.4 | 8.0 | False | None | None | False | None | False | 2419.2 | 0 | 3230749 | 111464 | None | Common SR V | Providing and installation of Class SN8 Double Wall Corrugated HDPE Specials outer wall corrugated and inner wall smooth piping system in accordance with IS 16098 part 2 and conveying to work site and
lowering into trenches, laying true to line and level and perfect linking at joints with the help of two "O" rings and a coupler of suitable size,including loading and unloading at both destination and cutting of pipes where ever necessary including jointing with all labour, all lead and lift including encasing the Specials around to a depth of not less than 15 cm with screened soft soil available from the excavated soil. The testing
commissioning including necessary hydraulic test to the required pressure as per ISS shall be done the contractor shall have to make his own arrangement for procuring water for testing etc. complete.(75 MM ELECTRO FUSION TEE) (Common SR Vol V 2023-24, Item No. 9.17.31 Pg.No. 108) | Each | 375.9 | 375.9 | 8.0 | False | None | None | False | None | False | 3007.2 | 0 | 3230750 | 111464 | None | Common SR V | Providing and fixing kinetic AIR VALVE of PN 16.0 for automatic discharge of accumulate air during working condition, conforming to IS 14845/ EN 1074-4. Body and bonnet of DI conforming to IS-1865 of grade GGG-40/50, seals are made of approved EPDM, SS 304 float, guide and internals. Flange drilling according to IS-1538 with appurtenances.complete. Body and bonnet shall be coated with electrostatically applied epoxy powder coating with a coating thickness of 250 micron both inside and outside etc. complete.(For K Air Valves of 80mm dia.).(For K Air Valves of 80mm dia.) (Common SR Vol V 2023-24, Item No. 35 / SR Code B083A Pg.No. 75) | Each | 27660.15 | 27660.15 | 2.0 | False | None | None | False | None | False | 55320.3 | 0 | 3230751 | 111464 | None | Common SR V | Providing and installation of Class SN8 Double Wall Corrugated HDPE Specials outer wall corrugated and inner wall smooth piping system in accordance with IS 16098 part 2 and conveying to work site and
lowering into trenches, laying true to line and level and perfect linking at joints with the help of two O rings and a coupler of suitable size,including loading and unloading at both destination and cutting of pipes
where ever necessary including jointing with all labour, all lead and lift including encasing the Specials around to a depth of not less than 15cm with screened soft soil available from the excavated soil. The testing commissioning including necessary hydraulic test to the required pressure as per ISS shall be done the contractor shall have to make his own arrangement for procuring water for testing etc. complete.(3 M.S. FLANGE) Common SR Vol V 2023-24, Item No. 9.17.40 Pg.No. 108 | Each | 210.0 | 210.0 | 16.0 | False | None | None | False | None | False | 3360.0 | 0 | 3230752 | 111464 | None | Common SR V | Providing and fixing of fixed height surface box H-4057 MD-KU with PP 40Percent GF Lid, Housing of PA+, Locking clip of PP with Notched bolt M 12 x 130 hexagon head A2-70 for service connection valves, design derived from DIN 4057, should be supplied with Support tile I (FSL, FSS, SI).
Should be able to receive class AA traffic loads etc. complete Common SR Vol V 2023-24, Item No. 2.50 Pg.No. 33 | Each | 2887.5 | 2887.5 | 8.0 | False | None | None | False | None | False | 23100.0 | 0 | 3230753 | 111464 | None | Common SR V | Providing and laying of warning tape / Caution tape / detector tape for HDPE pipes of 200 mm wide, 300 micron thick, blue in colour confoming to relevant ISS with latest amendments with appurtenances., complete COMMON SR 2023-24,Vol V Pg.No. 108 Sl.No.9.18 | Mtr | 8.4 | 8.4 | 7000.0 | False | None | None | False | None | False | 58800.0 | 0 | 3230754 | 111464 | None | Volume1 | Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m , and lift upto 1.5 m. Including cost of all labour complete as per specifications. COMMON SR 2023-24,Vol I, Pg.No. 7 Sl.No.1.10 | Cum | 168.0 | 168.0 | 1365.0 | False | None | None | False | None | False | 229320.0 | 0 |
|
|
---|