createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1715856146053
version9
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee2040.00
emd192100.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose21-06-2024 16:00:00
tenderQueryClose20-06-2024 17:30:00
technicalBidOpen24-06-2024 10:30:00
publishedDate13-06-2024 15:42:59
publishedByPostPWD_EE_DIV_MNG
publishedByUserKPE16430 - AMARNATHA JAIN H P
bidValidityPeriod90
noOfCalls2
preBidMeetingDateNone
preBidMeetingYnFalse
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnTrue
percentageRateTypeTextNone
contactPersonExecutive Engineer
splitEmdRequiredYnTrue
emdBankGuarantee142100.00
emdCash50000.00
bgValidityPeriod135
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumber08242423169
mobileNumberNone
tenderSupplierListNone
tenderSchedule
createdTs1715856146057
version15
createdDateNone
modifiedDateNone
tenderNumberPWD/2023-24/BD/WORK_INDENT7211/CALL-2
titlePROPOSED CONSTRUCTION OF SUB DIVISION OFFICE AT MOODBIDRI UNDER THE HEAD OF ACCOUNT 4059-80-051-0-29-386 DEPARTMENTAL BUILDINGS
descriptionCIVIL WORKS ,ELECTRICAL WORKS,SANITARY AND WATER SUPPLY WORKS
categoryWORKS
categoryTextWorks
ecv8139162.49
deptNamePublic Works Department
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnTrue
location1697
locationNamePWD Division Office Mangaluru
provisionalAmount10000000.0
groupOverheadTotal0.0
fileNumberMOODBIDRI
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17158561460001NoneNoneBuildingsPROPOSED CONSTRUCTION OF SUB DIVISION OFFICE AT MOODBIDRI UNDER THE HEAD OF ACCOUNT 4059-80-051-0-29-386 DEPARTMENTAL BUILDINGS7251187.03
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3137935107846NonePWD SR 2023-24 ITEM NO 1.12,VOL 1,PAGE NO 8Earth work in surface excavation by mechanical means for lowering &leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work.leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work.In all kinds of soils upto 300 mm depth ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.Cum106.4106.4107.1FalseNoneNoneFalseNoneFalse11395.440
3137936107846NonePWD SR 2023-24,ITEM NO 1.14.1,VOL1,PAGE NO 8Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting,barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.Cum114.24114.24293.65FalseNoneNoneFalseNoneFalse33546.5760
3137937107846NonePWD SR 2023-24,ITEM NO 1.5.1,VOL 1,PAGE NO 6Earth work excavation by manual means for drains,canals, waste weir,draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work.In all kinds of soils Depth upto 1.5 m ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.Cum334.88334.8832.0FalseNoneNoneFalseNoneFalse10716.160
3137938107846NonePWD SR 2023-24,I.No.2.1.2, page No.15, Vol-1Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork aggregateshall be paid separately)Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregate ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.Cum6343.686343.6841.41FalseNoneNoneFalseNoneFalse262691.78880
3137939107846NonePWD SR 2023-24 ,VOL1,PAGE 15 ,ITEM NO 2.2.1Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.Cum7604.767604.7643.18FalseNoneNoneFalseNoneFalse328373.53680
3137940107846NonePWD SR 2023-24 ,VOL1,PAGE 15 ,ITEM NO 2.2.1Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.Cum10562.1610562.1639.22FalseNoneNoneFalseNoneFalse414247.91520
3137941107846NonePWD SR 2023-24 ,VOL1,PAGE 15 ,ITEM NO 2.2.1CUMProviding and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.Cum11970.4511970.453.0FalseNoneNoneFalseNoneFalse35911.350
3137942107846NonePWD SR 2023-24 ,VOL1,PAGE 15 ,ITEM NO 2.2.1Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.Cum10562.1610562.160.76FalseNoneNoneFalseNoneFalse8027.24160
3137943107846NonePWD SR 2023-24,I.No.1.10, page No.7, Vol-1Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m , and lift upto 1.5 m. Including cost of all labour complete as per specifications ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.Cum179.2179.2464.75FalseNoneNoneFalseNoneFalse83283.20
3137944107846NonePWD SR 2023-24 ,VOL1,PAGE 7,ITEM NO1.9Filling available excavated earth (excluding rock) in trenches, plinth,sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.Cum297.92297.9283.21FalseNoneNoneFalseNoneFalse24789.92320
3137945107846NonePWD SR 2023-24 ,VOL1,PAGE 16 ,ITEM NO 2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregate ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.Cum13029.0713029.0712.71FalseNoneNoneFalseNoneFalse165599.47970
3137946107846NonePWD SR 2023-24 ,VOL1,PAGE 16,ITEM NO 2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregate ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.Cum12262.6612262.6620.17FalseNoneNoneFalseNoneFalse247337.85220
3137947107846NonePWD SR 2023-24 ,VOL1,PAGE 16,ITEM NO 2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregate ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.Cum11113.0311113.035.64FalseNoneNoneFalseNoneFalse62677.48920
3137948107846NonePWD SR 2023-24 ,VOL1,PAGE 16,ITEM NO 2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregate ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.Cum11496.2411496.2430.71FalseNoneNoneFalseNoneFalse353049.53040
3137949107846NonePWD SR 2023-24 ,VOL1,PAGE 16,ITEM NO 2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregate ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.Cum11496.2411496.245.9FalseNoneNoneFalseNoneFalse67827.8160
3137950107846NonePWD SR 2023-24 ,VOL1,PAGE 18,ITEM NO 2.11aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.Tonne100191.84100191.8417.81FalseNoneNoneFalseNoneFalse1784416.67040
3137951107846NonePWD SR 2023-24 ,VOL 2,PAGE 17,ITEM NO 6.32Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.Sqm1467.21467.2355.38FalseNoneNoneFalseNoneFalse521413.5360
3137952107846NonePWD SR 2023-24,VOL 2,ITEM NO 6.33,PAGE 17Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.Sqm1378.721378.7250.88FalseNoneNoneFalseNoneFalse70149.27360
3137953107846NonePWD SR 2023-24,VOL2 ,ITEM NO 6.34,PAGE NO 6.34Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.Sqm1236.481236.4882.96FalseNoneNoneFalseNoneFalse102578.38080
3137954107846NonePWD SR 2023-24,VOL 2,ITEM NO 5.1.1,PAGE NO 9Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with Cement mortar 1:6 (1 cement : 6 coarse sand ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.Cum6284.326284.327.4FalseNoneNoneFalseNoneFalse46503.9680
3137955107846NonePWD SR 2023-24,VOL 2,ITEM NO 8.2.1,PAGE NO 41Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.Sqm330.4330.4708.76FalseNoneNoneFalseNoneFalse234174.3040
3137956107846NonePWD SR 2023-24,VOL 2,ITEM NO 5.1.1,PAGE NO 9Providing 20 mm cement plaster of mix :1:6 (1 cement: 6 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.Sqm372.96372.96555.05FalseNoneNoneFalseNoneFalse207011.4480
3137957107846NonePWD SR 2023-24,VOL 2,ITEM NO 8.17.1,PAGE NO 44Providing Flush / Ruled/ Struck or weathered pointing Pointing on brick work or brick flooring with cement mortar 1:3 (1 cement : 3 fine sand) after raking joints to depth nicely lining, including cost of materials, labour, curing as per specifications and as per directions of Engineer in-charge ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.Sqm192.64192.64109.15FalseNoneNoneFalseNoneFalse21026.6560
3137958107846NonePWD SR 2023-24,VOL 2,ITEM NO 11.34B,PAGE NO 86Providing and fixing M.S. grills of required pattern in frames of win dows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.Kg204.96204.96601.02FalseNoneNoneFalseNoneFalse123185.05920
3137959107846NonePWD SR 2023-24,VOL 2,ITEM NO 11.35.1.3,PAGE NO 87Providing and fixing alluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS 733 and IS 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc Alluminium sections ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.Kg558.88558.88257.58FalseNoneNoneFalseNoneFalse143956.31040
3137960107846NonePWD SR 2023-24,VOL 2,ITEM NO 11.37.1,PAGE NO 89Providing and fixing glazing in aluminium door, window, ventilato shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness (weight not less than 10kg/ m²) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.Sqm1106.561106.5628.62FalseNoneNoneFalseNoneFalse31669.74720
3137961107846NonePWD SR 2023-24,VOL 2,ITEM NO 11.42.1,PAGE NO 91Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete: Upto 5mm depth and 5 mm width including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer in-Charg ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.Mtr69.4469.4497.2FalseNoneNoneFalseNoneFalse6749.5680
3137962107846NonePWD SR 2023-24,VOL 2,ITEM NO 12.12,PAGE NO 99Providing Mathi/Nandi wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.Cum139106.24139106.240.61FalseNoneNoneFalseNoneFalse84854.80640
3137963107846NonePWD SR 2023-24,VOL 2,ITEM NO 12.15,PAGE NO 100Providing and fixing in position fully panelled Mathi/Nandi wood shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. (excluding cost of fixtures) ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.Sqm8337.288337.2821.21FalseNoneNoneFalseNoneFalse176833.70880
3137964107846NonePWD SR 2023-24,VOL 2,ITEM NO 12.54,PAGE NO 104Providing & fixing factory made PVC Door frame of size 50x47mm wit a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge. ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.Sqm356.2356.27.88FalseNoneNoneFalseNoneFalse2806.8560
3137965107846NonePWD SR 2023-24,VOL 2,ITEM NO 12.55.1,PAGE NO 104Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.Sqm2649.92649.97.88FalseNoneNoneFalseNoneFalse20881.2120
3137966107846NonePWD SR 2023-24,VOL 2,ITEM NO 12.58,PAGE NO 105Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.No134.4134.410.0FalseNoneNoneFalseNoneFalse1344.00
3137967107846NonePWD SR 2023-24,VOL 2,ITEM NO 12.62,PAGE NO 105Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. complete ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.No265.44265.4410.0FalseNoneNoneFalseNoneFalse2654.40
3137968107846NonePWD SR 2023-24,VOL 2,ITEM NO 12.61,PAGE NO 105Providing and fixing chromium plated brass night latch of approved quality including necessary screws etc. complete ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.Nos1108.81108.81.0FalseNoneNoneFalseNoneFalse1108.80
3137969107846NonePWD SR 2023-24,VOL 2,ITEM NO 12.63,PAGE NO 105Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.Nos145.6145.621.0FalseNoneNoneFalseNoneFalse3057.60
3137970107846NonePWD SR 2023-24,VOL 2,ITEM NO 12.64,PAGE NO 105Providing and fixing PTMT door catcher of length 72 mm and dia. of 42 mm with suitable washers weighing not less than 33 gms ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.Nos61.661.610.0FalseNoneNoneFalseNoneFalse616.00
3137971107846NonePWD SR 2023-24,VOL 2,ITEM NO 12.70.1,PAGE NO 106Providing and fixing oxidised M.S. double acting spring hinges with necessary screws etc. complete.150 mm ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.Nos340.48340.4810.0FalseNoneNoneFalseNoneFalse3404.80
3137972107846NonePWD SR 2023-24,VOL 2,ITEM NO 9.7.1,PAGE NO 59Providing and fixing 10 mm thick acid and/or alkali resistant tiles of approved make and colour using acid and/or alkali resisting mortar bedding for Bathrooms: Toilet: Chemically exposed areas and joints filled with acid and/or alkali resisting cement as per IS : 4457, complete as per the direction of Engineer-in- Charge ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.Sqm1395.521395.52156.57FalseNoneNoneFalseNoneFalse218496.56640
3137973107846NonePWD SR 2023-24,VOL 2,ITEM NO 9.12.2,PAGE NO 60Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete Size of Tile 600x600 mm ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.Sqm1282.41282.4188.33FalseNoneNoneFalseNoneFalse241514.3920
3137974107846NonePWD SR 2023-24,VOL 2,ITEM NO 9.20.2,PAGE NO 62Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge Size of Tile 600x600 mm ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.Sqm234.1234.1188.33FalseNoneNoneFalseNoneFalse44088.0530
3137975107846NonePWD SR 2023-24,VOL 2,ITEM NO 9.30,PAGE NO 64Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.Sqm5967.45967.443.85FalseNoneNoneFalseNoneFalse261670.490
3137976107846NonePWD SR 2023-24,VOL 2,ITEM NO 8.32,PAGE NO 46Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.Sqm174.72174.72555.05FalseNoneNoneFalseNoneFalse96978.3360
3137977107846NonePWD SR 2023-24,VOL 2,ITEM NO 8.35.1,PAGE NO 47Painting with silicon & acrylic emulsion based water thinnable sealer of approved brand and manufacture on wet or patchy portion of plastered surfaces :One coat with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.Sqm221.8221.81002.11FalseNoneNoneFalseNoneFalse222267.9980
3137978107846NonePWD SR 2023-24,VOL 2,ITEM NO 8.39,PAGE NO 48Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.Sqm142.24142.241002.11FalseNoneNoneFalseNoneFalse142540.12640
3137979107846NonePWD SR 2023-24,VOL 2,ITEM NO 8.34.1,PAGE NO 47Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.Sqm59.3659.3640.32FalseNoneNoneFalseNoneFalse2393.39520
3137980107846NonePWD SR 2023-24,VOL 2,ITEM NO 8.51,PAGE NO 50Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.Sqm112.0112.01002.11FalseNoneNoneFalseNoneFalse112236.320
3137981107846NonePWD SR 2023-24,VOL 2,ITEM NO 8.33.2,PAGE NO 46Painting wood work with Deluxe Multi Surface Paint of required shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @0.75 ltr/10 m² of approved brand and manufacture to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.Sqm154.56154.5640.32FalseNoneNoneFalseNoneFalse6231.85920
3137982107846NonePWD SR 2023-24,VOL 2,ITEM NO 8.33.3,PAGE NO 47Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @ 0.80 ltr/10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.Sqm155.68155.6811.08FalseNoneNoneFalseNoneFalse1724.93440
3137983107846NonePWD SR 2023-24,VOL 2,ITEM NO 11.16.2,PAGE NO 82Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.Kg164.64164.64302.0FalseNoneNoneFalseNoneFalse49721.280
3137984107846NonePWD SR 2023-24,VOL 2,ITEM NO 7.38,PAGE NO 26Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.Sqm636.16636.1663.0FalseNoneNoneFalseNoneFalse40078.080
3137985107846NonePWD SR 2023-24,VOL 2,ITEM NO 11.28,PAGE NO 85Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.Kg632.8632.8176.0FalseNoneNoneFalseNoneFalse111372.80
17158561460000NoneNoneBuildingsESTIMATE FOR WATER SUPPLY AND SANITATION WORK282620.8
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3137986107847NonePWD SR 2023-24,ITEM NO 14.1.1,VOL 2,PAGE 131Water supply and sanitation work Providing and fixing water closet squatting pan (Indian type W.C. pan with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.No5470.085470.082.0FalseNoneNoneFalseNoneFalse10940.160
3137987107847NonePWD SR 2023-24,ITEM NO 14.2.1,VOL 2,PAGE 131Providing and fixing white vitreous china pedestal type water close (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fix tures complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.No5418.565418.563.0FalseNoneNoneFalseNoneFalse16255.680
3137988107847NonePWD SR 2023-24,ITEM NO 14.7.2,VOL 2,PAGE 132Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.No2868.322868.325.0FalseNoneNoneFalseNoneFalse14341.60
3137989107847NonePWD SR 2023-24,ITEM NO 14.10.2.1,VOL 2,PAGE 134Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : 610x510 mm bowl depth 200 mm ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.Each4060.04060.01.0FalseNoneNoneFalseNoneFalse4060.00
3137990107847NonePWD SR 2023-24,ITEM NO 14.36.2,VOL 2,PAGE 137Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour Waste coupling 38 mm dia of 83 mm length and 77mm breadth, weighing not less than 60 gms ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.No104.16104.165.0FalseNoneNoneFalseNoneFalse520.80
3137991107847NonePWD SR 2023-24,ITEM NO 14.37.2,VOL 2,PAGE 137Bottle trap 38 mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 263 gms ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.Each356.16356.165.0FalseNoneNoneFalseNoneFalse1780.80
3137992107847NonePWD SR 2023-24,ITEM NO 14.40.1,VOL 2,PAGE 137Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colou 450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 g. ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.No535.36535.365.0FalseNoneNoneFalseNoneFalse2676.80
3137993107847NonePWD SR 2023-24,ITEM NO 14.32.2,VOL 2,PAGE 136Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :Rectangular shape 453x357 mm ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.No1140.161140.165.0FalseNoneNoneFalseNoneFalse5700.80
3137994107847NonePWD SR 2023-24,ITEM NO 14.28.2.1,VOL 2,PAGE 136Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Flexible pipe 32 mm dia ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.No103.04103.045.0FalseNoneNoneFalseNoneFalse515.20
3137995107847NonePWD SR 2023-24,ITEM NO 14.16A,VOL 2,PAGE 134Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge. ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.No304.64304.643.0FalseNoneNoneFalseNoneFalse913.920
3137996107847NonePWD SR 2023-24,ITEM NO 16.10,VOL 5,PAGE 191Constructing brick masonry chamber of internal dimension 450x450mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.No4744.324744.323.0FalseNoneNoneFalseNoneFalse14232.960
3137997107847NonePWD SR 2023-24,ITEM NO 16.09,VOL 5,PAGE 191Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.No6108.486108.482.0FalseNoneNoneFalseNoneFalse12216.960
3137998107847NonePWD SR 2023-24,ITEM NO 16.15.1,VOL 5,PAGE 192Providing and constructing WIRE CUT BRICK MACHINEHOLE CHAMBERS using Portland ,Pozzolana cement, conical in shape at top, with CC 1:3:6 foundation using 40mm and down size graded metal of approved quality and with an offset of 0.15M alround the chamber. Construct Brick masonry in CM 1:4, 340 mm thick, with wirecut bricks of approved quality, plaster inside and out side with CM 1:3, 12mm thick, except for the conical surface outside where the plaster thickness shall be 20mm. Slope inside to be 1:6 in the concrete towards central drain and finished smooth. Fixing of pipes in CC 1:2:4 with graded metal of 20mm and down size. Supplying and fixing SFRC Machinehole frame and cover Heavy Duty conforming to IS 12592 with latest amendment, in CC 1:2:4. Supplying and fixing footsteps made of 12mm dia. steel bars Fe-500 with 3mm thick plastic encapsulation (IS-10910). The footsteps shall be fixed 30cms apart and on CC block embeded to masonry wall. The whole works include watering, curing, barricading, danger lighting, pouring tar over MH frame and cover, cost of tar, shoring, strutting, dewatering, engraving Machine hole number with flow direction on the inner conical surface etc. as per the drawing etc. as per technical specifications and for the following diameters and depth etc. for 1.2mm dia Circ. B M.H ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.No32532.6432532.641.0FalseNoneNoneFalseNoneFalse32532.640
3137999107847NonePWD SR 2023-24,ITEM NO 10.1.5,VOL 5,PAGE 113Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials excluding cost of specials with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS Contractor will make his own arrangements for procuring water for testing etc. for: PVC pipes 75mm dia., 6 kg/sqcm & class ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.Mtr246.4246.435.0FalseNoneNoneFalseNoneFalse8624.00
3138000107847NonePWD SR 2023-24,ITEM NO 10.1.7,VOL 5,PAGE 113Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials excluding cost of specials with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS Contractor will make his own arrangements for procuring water for testing etc. for: PVC pipes 110mm dia., 6 kg/sqcm & class 3 ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.Mtr460.32460.3225.0FalseNoneNoneFalseNoneFalse11508.00
3138001107847NonePWD SR 2023-24,ITEM NO 10.8.6,VOL 5,PAGE 116Supply and delivery at site special moulded variety PVC couplers as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark and with its latest amendments 75mm dia PVC couplers ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.No75.0475.048.0FalseNoneNoneFalseNoneFalse600.320
3138002107847NonePWD SR 2023-24,ITEM NO 10.8.8,VOL 5,PAGE 116Supply and delivery at site special moulded variety PVC couplers as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark and with its latest amendments ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.No191.52191.5212.0FalseNoneNoneFalseNoneFalse2298.240
3138003107847NonePWD SR 2023-24,ITEM NO 10.9.6,VOL 5,PAGE 117Supply and delivery at site special moulded variety PVC elbows as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.No215.04215.046.0FalseNoneNoneFalseNoneFalse1290.240
3138004107847NonePWD SR 2023-24,ITEM NO 10.9.8,VOL 5,PAGE 117110 mm dia PVC Elbows ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.No338.24338.248.0FalseNoneNoneFalseNoneFalse2705.920
3138005107847NonePWD SR 2023-24,ITEM NO 10.10.6,VOL 5,PAGE 117Supply and delivery at site special moulded variety PVC tee as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.No131.04131.045.0FalseNoneNoneFalseNoneFalse655.20
3138006107847NonePWD SR 2023-24,ITEM NO 10.11.8,VOL 5,PAGE 118Supply and delivery at site special moulded variety PVC bend as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.No551.04551.048.0FalseNoneNoneFalseNoneFalse4408.320
3138007107847NonePWD SR 2023-24,ITEM NO 11.2.6,VOL 5,PAGE 127Water supply work Providing, Laying and Fixing of GI pipes conforming to IS 1239:1990 with latest amendments complete with GI fittings (excluding the cost of fittings) with cuts and threads wherever necessary, including testing for water tightness, with all lead and commissioning. (contractor will make his own arrangements for procuring water for testing) For:Heavy Duty GI Pipe etc. complete. Medium Duty GI pipe of 50mm dia ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.No654.08654.0820.0FalseNoneNoneFalseNoneFalse13081.60
3138008107847NonePWD SR 2023-24,ITEM NO 11.2.5,PAGE NO 127Providing, Laying and Fixing of GI pipes conforming to IS 1239:1990 with latest amendments complete with GI fittings (excluding the cost of fittings) with cuts and threads wherever necessary, including testing for water tightness, with all lead and commissioning. (contractor will make his own arrangements for procuring water for testing) For:Heavy Duty GI Pipe etc. complete. Medium Duty GI pipe of 40mm dia ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.Mtr546.56546.5630.0FalseNoneNoneFalseNoneFalse16396.80
3138009107847NonePWDSR 2023-24,VOL 5 ,ITEM NO 11.2.3,PAGE NO 127Providing, Laying and Fixing of GI pipes conforming to IS 1239:1990 with latest amendments complete with GI fittings (excluding the cost of fittings) with cuts and threads wherever necessary, including testing for water tightness, with all lead and commissioning. (contractor will make his own arrangements for procuring water for testing) For:Heavy Duty GI Pipe etc. complete. Medium Duty GI pipe of 25mm dia ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.m360.64360.6440.0FalseNoneNoneFalseNoneFalse14425.60
3138010107847NonePWDSR 2023-24,ITEM NO 11.2.2,VOL 5,PAGE NO 127Providing, Laying and Fixing of GI pipes conforming to IS 1239:1990 with latest amendments complete with GI fittings (excluding the cost of fittings) with cuts and threads wherever necessary, including testing for water tightness, with all lead and commissioning. (contractor will make his own arrangements for procuring water for testing) For:Heavy Duty GI Pipe etc. complete. Medium Duty GI pipe of 20mm dia ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.m274.4274.425.0FalseNoneNoneFalseNoneFalse6860.00
3138011107847NonePWD SR 2023-24,ITEM NO 11.2.1,VOL 5,PAGE NO 127Providing, Laying and Fixing of GI pipes conforming to IS 1239:1990 with latest amendments complete with GI fittings (excluding the cost of fittings) with cuts and threads wherever necessary, including testing for water tightness, with all lead and commissioning. (contractor will make his own arrangements for procuring water for testing) For:Heavy Duty GI Pipe etc. complete. Medium Duty GI pipe of 15mm dia ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.m234.08234.0815.0FalseNoneNoneFalseNoneFalse3511.20
3138012107847NonePWD SR 2023-24,ITEM NO 11.6.6,VOL 5,PAGE 129Providing wrought mild steel (galvanized) 15 mm dia GI collar confirming to IS 1239-II, 1991 with latest amendments if any. Medium Duty GI Collor of 50mm dia ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.No299.04299.044.0FalseNoneNoneFalseNoneFalse1196.160
3138013107847NonePWD SR 2023-24,ITEM NO 11.6.5,PAGE NO 129,VOL5Providing wrought mild steel (galvanized) 15 mm dia GI collar confirming to IS 1239-II, 1991 with latest amendments if any. Medium Duty GI Collor of 40mm dia ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.No230.72230.726.0FalseNoneNoneFalseNoneFalse1384.320
3138014107847NonePWD SR 2023-24,ITEM NO 11.6.3,VOL 5,PAGE 129Providing wrought mild steel (galvanized) 15 mm dia GI collar confirming to IS 1239-II, 1991 with latest amendments if any. Medium Duty GI Collor of 25mm dia ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.No157.92157.925.0FalseNoneNoneFalseNoneFalse789.60
3138015107847NonePWD SR 2023-24,ITEM NO 11.6.2,VOL 5,PAGE 129Providing wrought mild steel (galvanized) 15 mm dia GI collar confirming to IS 1239-II, 1991 with latest amendments if any. Medium Duty GI Collor of 20mm dia ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.No110.88110.884.0FalseNoneNoneFalseNoneFalse443.520
3138016107847NonePWD SR 2023-24,ITEM NO 11.6.1,VOL 5 ,PAGE NO 129Providing wrought mild steel (galvanized) 15 mm dia GI collar confirming to IS 1239-II, 1991 with latest amendments if any. Medium Duty GICollor of 15mm dia ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.No66.0866.085.0FalseNoneNoneFalseNoneFalse330.40
3138017107847NonePWDSR 2023-24,ITEM NO 11.7.6,VOL 5,PAGE NO 129Supply and delivery at site wrought middle steel (galvanized) GI elbow confirming to IS 1239-II, 1991 with latest amendments if any for Medium Duty GI Elbow of 50mm dia ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.No299.04299.044.0FalseNoneNoneFalseNoneFalse1196.160
3138018107847NonePWD SR 2023-24,ITEM NO 11.7.5,VOL 5,PAGE 129Supply and delivery at site wrought middle steel (galvanized) GI elbow confirming to IS 1239-II, 1991 with latest amendments if any for Medium Duty GI Elbowr of 40mm dia ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.No230.72230.726.0FalseNoneNoneFalseNoneFalse1384.320
3138019107847NonePWD SR 2023-24,ITEM NO 11.7.3,VOL 5,PAGE 129Supply and delivery at site wrought middle steel (galvanized) GI elbow confirming to IS 1239-II, 1991 with latest amendments if any for Medium Duty GI Elbowr of 25mm dia ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.No135.52135.525.0FalseNoneNoneFalseNoneFalse677.60
3138020107847NonePWD SR 2023-24,ITEM NO 11.7.2,VOL 5,PAGE 129Supply and delivery at site wrought middle steel (galvanized) GI elbow confirming to IS 1239-II, 1991 with latest amendments if any for Medium Duty GI Elbow of 20mm dia ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.No110.88110.886.0FalseNoneNoneFalseNoneFalse665.280
3138021107847NonePWD SR 2023-24,ITEM NO 11.7.1,VOL 5,PAGE 129Supply and delivery at site wrought middle steel (galvanized) GI elbow confirming to IS 1239-II, 1991 with latest amendments if any for Medium Duty GICollor of 15mm dia ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.No66.0866.085.0FalseNoneNoneFalseNoneFalse330.40
3138022107847NonePWD SR 2023-24,ITEM NO 11.9.6,VOL 5,PAGE 129Supply and delivery at site wrought middle steel (galvanized) GI tee confirming to IS 1239-II, 1991 with latest amendments if any Medium Duty GI Tee of 50mm dia ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.No332.64332.643.0FalseNoneNoneFalseNoneFalse997.920
3138023107847NonePWD SR 2023-24,ITEM NO 11.9.5,VOL 5,PAGE 129Supply and delivery at site wrought middle steel (galvanized) GI tee confirming to IS 1239-II, 1991 with latest amendments if any Medium Duty GI Teer of 40mm dia ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.No212.8212.84.0FalseNoneNoneFalseNoneFalse851.20
3138024107847NonePWD SR 2023-24,ITEM NO 11.9.3VOL 5,PAGE 129Supply and delivery at site wrought middle steel (galvanized) GI tee confirming to IS 1239-II, 1991 with latest amendments if any Medium Duty GI Tee of 25mm dia ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.No154.56154.564.0FalseNoneNoneFalseNoneFalse618.240
3138025107847NonePWD SR 2023-24,ITEM NO 11.9.2,VOL 5,PAGE 129Supply and delivery at site wrought middle steel (galvanized) GI tee confirming to IS 1239-II, 1991 with latest amendments if any Medium Duty GITee of 20mm dia ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.No119.84119.845.0FalseNoneNoneFalseNoneFalse599.20
3138026107847NonePWD SR 2023-24,ITEM NO 11.9.1,VOL 5,PAGE 129Supply and delivery at site wrought middle steel (galvanized) GI tee confirming to IS 1239-II, 1991 with latest amendments if any Medium Duty GITee of 15mm dia ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.No68.3268.324.0FalseNoneNoneFalseNoneFalse273.280
3138027107847NonePWD SR 2023-24,ITEM NO 11.12.6,VOL 5,PAGE 129Supply and delivery at site wrought middle steel (galvanized) GI union confirming to IS 1239-II, 1991 with latest amendments if any Medium Duty GI Union of 50mm dia ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.No299.04299.045.0FalseNoneNoneFalseNoneFalse1495.20
3138028107847NonePWD SR 2023-24,ITEM NO 11.12.5,VOL 5,PAGE 129Supply and delivery at site wrought middle steel (galvanized) GI union confirming to IS 1239-II, 1991 with latest amendments if any Medium Duty GI Union of 40mm dia ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.No265.44265.444.0FalseNoneNoneFalseNoneFalse1061.760
3138029107847NonePWD SR 2023-24,ITEM NO 11.12.3,VOL 5,PAGE 129Supply and delivery at site wrought middle steel (galvanized) GI union confirming to IS 1239-II, 1991 with latest amendments if any Medium Duty GI Union of 25mm dia ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.No179.2179.24.0FalseNoneNoneFalseNoneFalse716.80
3138030107847NonePWD SR 2023-24,ITEM NO 11.12.2VOL 5,PAGE 129Supply and delivery at site wrought middle steel (galvanized) GI union confirming to IS 1239-II, 1991 with latest amendments if any Medium Duty GIUnion of 20mm dia ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.No144.48144.485.0FalseNoneNoneFalseNoneFalse722.40
3138031107847NonePWD SR 2023-24,ITEM NO 11.12.1,VOL 5,PAGE 129Supply and delivery at site wrought middle steel (galvanized) GI union confirming to IS 1239-II, 1991 with latest amendments if any Medium Duty GIUnion of 15mm dia ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.No94.0894.086.0FalseNoneNoneFalseNoneFalse564.480
3138032107847NonePWD SR 2023-24,ITEM NO 11.14.6,VOL 5,PAGE 131Supply and delivery at site wrought middle steel (galvanized) GI hexagonal nipple confirming to IS 1239-II, 1991 with latest amendments if any. Medium Duty GI Nipple of 50mm dia ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.No238.56238.563.0FalseNoneNoneFalseNoneFalse715.680
3138033107847NonePWD SR 2023-24,ITEM NO 11.14.5,VOL 5,PAGE 131Supply and delivery at site wrought middle steel (galvanized) GI hexagonal nipple confirming to IS 1239-II, 1991 with latest amendments if any. Medium Duty GI Nipple of 40mm dia ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.No204.96204.964.0FalseNoneNoneFalseNoneFalse819.840
3138034107847NonePWD SR 2023-24,ITEM NO 11.14.3,VOL 5,PAGE 131Supply and delivery at site wrought middle steel (galvanized) GI hexagonal nipple confirming to IS 1239-II, 1991 with latest amendments if any. Medium Duty GI Nipple of 25mm dia ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.No144.48144.485.0FalseNoneNoneFalseNoneFalse722.40
3138035107847NonePWD SR 2023-24,ITEM NO 11.14.2,VOL 5,PAGE 132Supply and delivery at site wrought middle steel (galvanized) GI hexagonal nipple confirming to IS 1239-II, 1991 with latest amendments if any. Medium Duty GI Nipple of 20mm dia ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.No110.88110.884.0FalseNoneNoneFalseNoneFalse443.520
3138036107847NonePWD SR 2023-24,ITEM NO 11.14.1,VOL 5,PAGE 132Supply and delivery at site wrought middle steel (galvanized) GI hexagonal nipple confirming to IS 1239-II, 1991 with latest amendments if any. Medium Duty GI Nipple of 15mm dia ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.No94.0894.0810.0FalseNoneNoneFalseNoneFalse940.80
3138037107847NonePWD SR 2023-24,ITEM NO 11.16.6,VOL 5,PAGE 133Providing GM (copper alloy) reflex valves/ globe valves confirming to Class-I and as per IS 778/1990 with latest amendments, 1 No. and with ISI mark screwed female ends confirming to IS 554/ 1990 horizontal body hydraulically tested for 1.50 HP and seat hydraulically tested 1 HP etc. For 50 mm dia GM (Copper alloy) valves ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.No889.28889.281.0FalseNoneNoneFalseNoneFalse889.280
3138038107847NonePWD SR 2023-24,ITEM NO 11.16.5,VOL 5,PAGE 133Providing GM (copper alloy) reflex valves/ globe valves confirming to Class-I and as per IS 778/1990 with latest amendments, 1 No. and with ISI mark screwed female ends confirming to IS 554/ 1990 horizontal body hydraulically tested for 1.50 HP and seat hydraulically tested 1 HP etc. For 40 mm dia GM (Copper alloy) valves ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.No805.28805.282.0FalseNoneNoneFalseNoneFalse1610.560
3138039107847NonePWD SR 2023-24,ITEM NO 11.16.3,VOL 5,PAGE 133Providing GM (copper alloy) reflex valves/ globe valves confirming to Class-I and as per IS 778/1990 with latest amendments, 1 No. and with ISI mark screwed female ends confirming to IS 554/ 1990 horizontal body hydraulically tested for 1.50 HP and seat hydraulically tested 1 HP etc. For 25 mm dia GM (Copper alloy) valves ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.No602.56602.562.0FalseNoneNoneFalseNoneFalse1205.120
3138040107847NonePWD SR 2023-24,ITEM NO 11.20.6,VOL 5,PAGE 135Lowering, Laying and Jointing GI pipes conforming to IS 1239:1990 with latest amendments complete with GI fittings (excluding the cost of fittings) with cuts and threads wherever necessary, including testing for water tightness, with all lead and commissioning. (contractor will make his own arrangements for procuring water for testing) for: Medium Duty GI pipe of 50mm dia ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.No162.4162.420.0FalseNoneNoneFalseNoneFalse3248.00
3138041107847NonePWD SR 2023-24,ITEM NO 11.20.5,VOL 5,PAGE 135Lowering, Laying and Jointing GI pipes conforming to IS 1239:1990 with latest amendments complete with GI fittings (excluding the cost of fittings) with cuts and threads wherever necessary, including testing for water tightness, with all lead and commissioning. (contractor will make his own arrangements for procuring water for testing) for: Medium Duty GI pipe of 40mm dia ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.No131.04131.0430.0FalseNoneNoneFalseNoneFalse3931.20
3138042107847NonePWD SR 2023-24,ITEM NO 11.20.3,VOL 5,PAGE 135Lowering, Laying and Jointing GI pipes conforming to IS 1239:1990 with latest amendments complete with GI fittings (excluding the cost of fittings) with cuts and threads wherever necessary, including testing for water tightness, with all lead and commissioning. (contractor will make his own arrangements for procuring water for testing) for: Medium Duty GI pipe of 25mm dia ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.No113.12113.1240.0FalseNoneNoneFalseNoneFalse4524.80
3138043107847NonePWD SR 2023-24,ITEM NO 11.20.2,VOL 5,PAGE 135Lowering, Laying and Jointing GI pipes conforming to IS 1239:1990 with latest amendments complete with GI fittings (excluding the cost of fittings) with cuts and threads wherever necessary, including testing for water tightness, with all lead and commissioning. (contractor will make his own arrangements for procuring water for testing) for: Medium Duty GI pipe of 20mm dia ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.No97.4497.4425.0FalseNoneNoneFalseNoneFalse2436.00
3138044107847NonePWD SR 2023-24,ITEM NO 11.20.1,VOL 5,PAGE 135Lowering, Laying and Jointing GI pipes conforming to IS 1239:1990 with latest amendments complete with GI fittings (excluding the cost of fittings) with cuts and threads wherever necessary, including testing for water tightness, with all lead and commissioning. (contractor will make his own arrangements for procuring water for testing) for: Medium Duty GI pipe of 15mm dia ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.No97.4497.4415.0FalseNoneNoneFalseNoneFalse1461.60
3138045107847NonePWD SR 2023-24,ITEM NO 13.34,VOL 2,PAGE 123Providing, Laying and Fixing HDPE Water storage tank (4 layer ,uv resistance ) complete with all fittings fittings (excluding the cost of fittings) with cuts and threads wherever necessary, including testing for water tightness, with all lead and commissioning. (contractor will make his own arrangements for procuring water for testing) . ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.Ltr10.0810.084000.0FalseNoneNoneFalseNoneFalse40320.00
17158561460000NoneNoneBuildingsDetailed Sub Estimate for Providing Electrification to Proposed Sub Division office Building at Moodabiri in D.K.District.605354.66
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3138046107848Nonevol 6 ,page 2 , item no 1.2.1,chapter 1Concealed Conduit System "Supplying heavy gauge PVC conduit pipe ……mm dia .mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary. ( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )" 19/20mm dia 2mm thick ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.m66.066.0180.0FalseNoneNoneFalseNoneFalse11880.00
3138047107848Nonevol 6,page 2 ,item no 1.2.2,chapter 1Concealed Conduit System "Supplying heavy gauge PVC conduit pipe ……mm dia .mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary. ( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )" ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.m78.078.0200.0FalseNoneNoneFalseNoneFalse15600.00
3138048107848Nonevol 6,ITEM NO 1.3.1,PAGE 2,chapter 1Supplying heavy gauge PVC Conduit Pipe ….dia .mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. ( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) ) 19/20mm dia 2mm thick ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.m68.068.0140.0FalseNoneNoneFalseNoneFalse9520.00
3138049107848Nonepage 2,sl no 1.3.2,chapter 1,vol 6Supplying heavy gauge PVC Conduit Pipe ….dia .mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. ( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) ) 25mm dia 2mm thick ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.m79.079.0170.0FalseNoneNoneFalseNoneFalse13430.00
3138050107848Noneitem no 1.5.1,vol 6Supplying and fixing PVC/metal conduit Deep junction box. ( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) ) 19/20 mm deep Junction box ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.Each49.049.030.0FalseNoneNoneFalseNoneFalse1470.00
3138051107848Noneitem no 1.5.2,vol 6Supplying and fixing PVC/metal conduit Deep junction box. ( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) ) 25 mm deep Junction box ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.Each56.056.030.0FalseNoneNoneFalseNoneFalse1680.00
3138052107848Noneitem no 1.13,vol 6 Supplying And Fixing Metal Fan Box with Round Hook.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) ) ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.No117.0117.015.0FalseNoneNoneFalseNoneFalse1755.00
3138053107848Noneitem no 5.19.9,vol 6Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG MS enclosure.-111-Double Door,( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) ) II - Double Door ,12 Way SP & N ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.Each2329.02329.02.0FalseNoneNoneFalseNoneFalse4658.00
3138054107848NoneI.No.3.4.1, Vol-6Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall ,( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) ) 1-2 Way ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.Each138.0138.015.0FalseNoneNoneFalseNoneFalse2070.00
3138055107848Noneitem no 3.4.3,vol 6Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall ,( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) ) 4-5Way ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.Each177.0177.06.0FalseNoneNoneFalseNoneFalse1062.00
3138056107848Noneitem no 3.4.4,vol 6Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall ,( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) ) 6Way ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.Each220.0220.06.0FalseNoneNoneFalseNoneFalse1320.00
3138057107848NoneI.No.3.4.5, vol 6Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall ,( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) ) 8Way ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.Each261.0261.015.0FalseNoneNoneFalseNoneFalse3915.00
3138058107848NoneI.No.3.4.6, ,Vol-6Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall ,( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) ) 10-12Way ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.Each319.0319.010.0FalseNoneNoneFalseNoneFalse3190.00
3138059107848Noneitem no 3.5.1,vol 6Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) ) 1-2 Module ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.Each137.0137.015.0FalseNoneNoneFalseNoneFalse2055.00
3138060107848NoneI.No.3.5.3,vol6Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) ) 4 Module ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.Each175.0175.06.0FalseNoneNoneFalseNoneFalse1050.00
3138061107848Noneitem no 3.5.4,vol 6Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) ) 6 Module ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.Each234.0234.06.0FalseNoneNoneFalseNoneFalse1404.00
3138062107848NoneI.No.3.5.5,vol 6Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) ) 8 Module ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.Each284.0284.015.0FalseNoneNoneFalseNoneFalse4260.00
3138063107848Noneitem no 3.5.6Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) ) 10-12 Module ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.Each344.0344.010.0FalseNoneNoneFalseNoneFalse3440.00
3138064107848NoneI.No.2.2.1,vol 6Wires and Cables-Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block.complete for each outlet.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) ) Short point upto 3Mtr from tapping point to out let via switch box ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.Point269.0269.020.0FalseNoneNoneFalseNoneFalse5380.00
3138065107848NoneI.No.2.2.3,vol 6Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block.complete for each outlet.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) ) Medium point above 3Mtr upto 6Mtr from tapping point to outlet via switch box ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.Point379.0379.026.0FalseNoneNoneFalseNoneFalse9854.00
3138066107848Noneitem no 2.2.3,vol 6Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block.complete for each outlet.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) ) Long point above 6Mtr upto 10Mtr from tapping point to outlet via switch box ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.Point555.0555.026.0FalseNoneNoneFalseNoneFalse14430.00
3138067107848Noneitem no 3.6.1,vol 6Supplying and fixing of modular switch/ Socket/stepped electronic fan regulator/ dimmer/telephone socket etc on existing modular switch plate. Is 3854 and IS 1293.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) 6Amps one way Switch ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.Each102.0102.0112.0FalseNoneNoneFalseNoneFalse11424.00
3138068107848Noneitem no 3.6.2,vol 6Supplying and fixing of modular switch/ Socket/stepped electronic fan regulator/ dimmer/telephone socket etc on existing modular switch plate. Is 3854 and IS 1293.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) 6Amps Two way Switch ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.Each166.0166.02.0FalseNoneNoneFalseNoneFalse332.00
3138069107848NoneI.No.3.6.3,vol 6Supplying and fixing of modular switch/ Socket/stepped electronic fan regulator/ dimmer/telephone socket etc on existing modular switch plate. Is 3854 and IS 1293.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) 6Amps 3way socket ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.Each171.0171.040.0FalseNoneNoneFalseNoneFalse6840.00
3138070107848NoneI.No.3.6.4 ,Vol-6Supplying and fixing of modular switch/ Socket/stepped electronic fan regulator/ dimmer/telephone socket etc on existing modular switch plate. Is 3854 and IS 1293.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) Stepped Fan Regulator Two Module ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.Each357.0357.014.0FalseNoneNoneFalseNoneFalse4998.00
3138071107848NoneITEM NO 3.6.8,VOL 6Supplying and fixing of modular switch/ Socket/stepped electronic fan regulator/ dimmer/telephone socket etc on existing modular switch plate. Is 3854 and IS 1293.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) 6Amps Bell push ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.Each177.0177.02.0FalseNoneNoneFalseNoneFalse354.00
3138072107848Noneitem no 3.6.9,vol 6Supplying and fixing of modular switch/ Socket/stepped electronic fan regulator/ dimmer/telephone socket etc on existing modular switch plate. Is 3854 and IS 1293.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) 32Amps DP switch ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.Each326.0326.010.0FalseNoneNoneFalseNoneFalse3260.00
3138073107848NoneITEM NO 3.6.10,VOL 6Supplying and fixing of modular switch/ Socket/stepped electronic fan regulator/ dimmer/telephone socket etc on existing modular switch plate. Is 3854 and IS 1293.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) 6/16Amps universal socket ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.Each236.0236.06.0FalseNoneNoneFalseNoneFalse1416.00
3138074107848Noneitem no 3.6.11,vol 6Supplying and fixing of modular switch/ Socket/stepped electronic fan regulator/ dimmer/telephone socket etc on existing modular switch plate. Is 3854 and IS 1293.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) TV / Telephone Socket ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.Each156.0156.06.0FalseNoneNoneFalseNoneFalse936.00
3138075107848Noneitem no 3.6.12Supplying and fixing of modular switch/ Socket/stepped electronic fan regulator/ dimmer/telephone socket etc on existing modular switch plate. Is 3854 and IS 1293.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) RJ45 / I.O out let Cat-6 ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.Each337.0337.010.0FalseNoneNoneFalseNoneFalse3370.00
3138076107848NoneITEM NO 2.3.2,VOL 6Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) 1.5 sqmm ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.m26.026.0680.0FalseNoneNoneFalseNoneFalse17680.00
3138077107848NoneITEM NO 2.3.3,VOL 6Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) 2.5 sqmm ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.m42.042.0650.0FalseNoneNoneFalseNoneFalse27300.00
3138078107848NoneI.No.2.3.4, Vol-6Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) 4 sqmm ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.m63.063.0450.0FalseNoneNoneFalseNoneFalse28350.00
3138079107848NoneI.No.2.3.5,vol 6Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) 6 sqmm ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.m92.092.050.0FalseNoneNoneFalseNoneFalse4600.00
3138080107848NoneI.No.5.12.1 ,vol 6Supplying of on load change over switches 4 poles, AC-23A Duty, 415V, 50Hz, AC Supply. With all accessories. (SM Enclosure Sheet Metal Execution)( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) 63 A ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.Each6881.06881.01.0FalseNoneNoneFalseNoneFalse6881.00
3138081107848NoneI.No.13.18.4,vol 6Fixing of . A TPST / change over switch / Contactor along with neutral link with screws, bolts, nuts and wiring using required capacity wires and circuit labelling.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) 15A to 63A TPDT/COS ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.Each290.0290.01.0FalseNoneNoneFalseNoneFalse290.00
3138082107848NoneI.No.5.15.9 ,vol 6Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuitwith adjustable thermal magnetic release, Micro processor release shall have Earth Fault as per IS/IEC 60947-2 . (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) FOUR Pole 100 A 25 kA ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.Each8487.08487.01.0FalseNoneNoneFalseNoneFalse8487.00
3138083107848NoneI.No.5.18.4 ,Vol-6Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898,( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) 6-32 Amps DP ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.Each739.0739.012.0FalseNoneNoneFalseNoneFalse8868.00
3138084107848NoneI.No.5.18.5, Vol-6Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898,( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) 40Amps TPN ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.Each3044.03044.08.0FalseNoneNoneFalseNoneFalse24352.00
3138085107848NoneI.No.5.21 , Vol-6Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.Each9255.09255.01.0FalseNoneNoneFalseNoneFalse9255.00
3138086107848NoneI.No.5.32, Vol-6Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, kVA, kWH, kVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.Each9315.09315.01.0FalseNoneNoneFalseNoneFalse9315.00
3138087107848NoneI.No.5.35, Vol-6Supplying, fixing and wiring Electronic Trivector Meter (ETV) 5 to 32/63 A three phase 4 wire whole current class-1 Accuracy Energy Meter.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) ) ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.Each5705.05705.01.0FalseNoneNoneFalseNoneFalse5705.00
3138088107848NoneI.No.5.38, Vol-6Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz 12/24V D.C.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) ) ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.Each515.0515.01.0FalseNoneNoneFalseNoneFalse515.00
3138089107848NoneI.No.5.34, Vol-6Supplying, fixing and wiring 50/5 to 400/5A 5VA burden Current Transformer Class 0.5 accuracy with Tape Wound.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) ) ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.Each562.0562.03.0FalseNoneNoneFalseNoneFalse1686.00
3138090107848NoneI.No.5.42.2 Vol-6Fabricating supplying and mounting MS box made out .SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) ) 16SWG ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.Sq0.430.4360000.0FalseNoneNoneFalseNoneFalse25800.00
3138091107848NoneI.No.5.40.1, Vol-6Supplying . A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete,.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) ) 100Amps 4x30x6mm Aluminium Strips ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.m2465.02465.01.0FalseNoneNoneFalseNoneFalse2465.00
3138092107848NoneI.No.5.41.2 , Vol-6Supplying and fixing angle iron frame work fabricated out of M.S. angle iron. and M.S. flat … with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) ) 50x50x6mm ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.m395.0395.06.0FalseNoneNoneFalseNoneFalse2370.00
3138093107848Noneitem no 11.3.2,vol 6Supplying of .feet -PVC Batten with integrated LED tube . W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI greater than 80. Power Input: 220-240V at 50/60Hz & Power factor greater than 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical )LED light fighting 1 x4'- 20/22 w ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.Each690.0690.034.0FalseNoneNoneFalseNoneFalse23460.00
3138094107848NoneI.No.11.11.4,Vol-6Supplying & fixing of retrofit type - LED bulb . W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI greater than 70%. efficacy greater than 80 lumen per W, life greater than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF greater than 0.95, power loss should less than 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) 9 W , 6500 K ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.Each154.0154.06.0FalseNoneNoneFalseNoneFalse924.00
3138095107848NoneI.No.11.5.2, Vol-6Supply of round/square recess/surface mounted rolling type LED Down light with . W GU 10 LED Lamp Rib Fabricated from diecast aluminium with white powder coated prewired to mains connector & has swivelling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI greater than 80. Power Input: 220-240V @50/60Hz & Power factor great than 0.9 along with CE approved. 2years Warranty against any manufacturing defect working under standard electrical condition.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) LED square or round down light 10-12W ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.Each885.0885.04.0FalseNoneNoneFalseNoneFalse3540.00
3138096107848NoneI.No.11.8.2 ,Vol-6Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT greater than 5500K, IP66 optical and electrical compartment & impact resistance of complete luminaire greater than IK08. Power Factor greater than 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with .W System Power consumption. LED Efficiencygreater than 1301m/w, nominal CRI greater than 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical LED Streetlight 40W, ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.Each4024.04024.03.0FalseNoneNoneFalseNoneFalse12072.00
3138097107848NoneI.No.6.2.1 ,Vol-6Supplying of 1440rpm heavy duty exhaust fan with bracket blades suitable to operate on 230V 50Hz, AC Supply complete. 12" Sweep (300 mm) ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.Each2969.02969.03.0FalseNoneNoneFalseNoneFalse8907.00
3138098107848NoneI.No.6.4.1 Vol-6Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/79 and also comply with IS: 1709/1984 with latest amendment, Rated voltage 220 V/50 Hz, Rated power input 48 W +/- 10 %, Rated current As per IS:374/79, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value 4.2 CMM / W, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201, as per IS specification, Motor winding. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 V, Insulation resistance Shall not be less than Two Mega Ohms (2M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, W& current, Air Delivery & Fan Speed as per IS:374/1979 with latest amendment, 2 year manufacturer Warranty.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) 48" Sweep 5 Star (1200mm) ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.Each2677.02677.014.0FalseNoneNoneFalseNoneFalse37478.00
3138099107848NoneI.No.13.2.2, Vol-6Supplying and Fixing.mm dia class A GI pipe bracket upto 2.7 meters long terminated with a reducing collar of 40x25mm to which extra pipe of 175mm length is fixed for fixing MV/SV/MH/FTL street light fitting of all capacities on rail/RCC/wall/tubular pole, using suitable clA, bolts, nuts and wiring using suitable capacity wires.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) Using 32mm dia G.I.Pipe ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.Each1295.01295.03.0FalseNoneNoneFalseNoneFalse3885.00
3138100107848NoneI.No.13.7.1,Vol-6Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) On wall / ceiling / Rafter / Girders ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.Each122.0122.044.0FalseNoneNoneFalseNoneFalse5368.00
3138101107848NoneI.No.13.11, vol 6Fixing a ceiling / wall mounting fan of all capacities and all types, with necessary clamps and 'S' hook made out of 15mm dia MS rod, with 5 amps. ceiling rose of approved quality with necessary length of 23 / 0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size wooden board and wired.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.Each315.0315.014.0FalseNoneNoneFalseNoneFalse4410.00
3138102107848NoneI.No.13.12,Vol-6Extra length of GI pipe of class B 19mm dia for down rod.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.Each197.0197.014.0FalseNoneNoneFalseNoneFalse2758.00
3138103107848NoneI.No.13.13 vol6Fixing one exhaust fan after making a suitable nitch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 amps, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.Each707.0707.03.0FalseNoneNoneFalseNoneFalse2121.00
3138104107848NoneI.No.12.2.1, Vol-6Supplying and fixing one of 230 V Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. Ding Dong Bell ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.Each246.0246.02.0FalseNoneNoneFalseNoneFalse492.00
3138105107848NoneI.No.8.1, Vol-6NETWORKING & TELECOMUNICATION Supplying and drawing UTP-CAT 6E LAN cable.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.m38.038.0800.0FalseNoneNoneFalseNoneFalse30400.00
3138106107848NoneI.No.8.2,Vol-6Supplying and drawing PVC flexible one pair telephone unarmoured tinned copper cable.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.m21.021.0200.0FalseNoneNoneFalseNoneFalse4200.00
3138107107848NoneI.No.8.9.2, Vol-6Supplying fixing of Network Switches.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) 24 Port Gigabyte (manageable) ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.Each41450.041450.01.0FalseNoneNoneFalseNoneFalse41450.00
3138108107848NoneI.No.8.10.1,Vol-6Supplying & fixing of I/O socket with back box. ( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.Each490.0490.010.0FalseNoneNoneFalseNoneFalse4900.00
3138109107848NoneI.No.8.11.1, Vol-6Supplying & Fixing of . ms Cat 6 Patch Cable.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) 1 m ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.Each224.0224.010.0FalseNoneNoneFalseNoneFalse2240.00
3138110107848NoneITEM NO6a,VOL 6a) Grounding of towers including cost of 40mm dia 2.5 mm thick, class 'C' G.I. Pipe of 3 Mtrs length as per specifications, with 50X6 mm GI Flats 3 Mtr long, salt charcoal, including excavation charges.( COMMON Electrical SR of 2023-24, BESCOM-PART -II,Rates for Labour of Major Works ) Maerial cost Rs. ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.Set5224.05224.04.0FalseNoneNoneFalseNoneFalse20896.00
3138111107848NoneITEM NO 6a,VOL 6a) Grounding of towers including cost of 40mm dia 2.5 mm thick, class 'C' G.I. Pipe of 3 Mtrs length as per specifications, with 50X6 mm GI Flats 3 Mtr long, salt charcoal, including excavation charges.( COMMON Electrical SR of 2023-24, BESCOM-PART -II,Rates for Labour of Major Works ) Labour charges 45 % Locality charges ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.Set3060.953060.954.0FalseNoneNoneFalseNoneFalse12243.80
3138112107848NoneITEM NO 26f,VOL 6,KPTCL SR 2023-24 PAGE 123Grounding of equipment with 50 x 6 mm G.I. Flat and connecting equipment to the earthmat/ground pit. Each point of earthing with all formation works like bending, twisting, drilling of holes and connecting by welding (inclusive of all T&P and consumables) to the earthmat/ground pit/point of earth connection, all the materials supplied by the contractor.( COMMON Electrical SR of 2023-24, BESCOM-PART -II,Rates for Labour of Major Works ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.Rmtr335.0335.030.0FalseNoneNoneFalseNoneFalse10050.00
3138113107848NoneITEM NO 32.11,VOL 6Supplying of 1.1 KV ,XLPE or Heat reisistant PVC insulated , PVC extrusted inner seath Armored , LTUG Cable as per IS-1554 ( Part-1) or IS-7098 Part-1 , Armouring strip thickness and resistively as per IS-3975,.( COMMON Electrical SR of 2023-24,BESCOM-Standard Stock Materials 11 KV System 50 Sqmm, 3.5 Core 16 GI Strips - 4 x 0.8 mm) ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.Km178973.0178973.00.1FalseNoneNoneFalseNoneFalse17897.30
3138114107848NoneITEM NO 1.6.1,PAGE 6,VOL 1Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock)in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work.( COMMON Electrical SR of 2023-24, PWD CIVIL SR CHAPTER-1 ) In all kinds of soils. Depth upto 1.50m ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.m542.08542.0818.0FalseNoneNoneFalseNoneFalse9757.440
3138115107848NoneITEM NO 1.10,VOL 1,PAGE 7Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m, and lift upto 1.5 m. Including cost of all labour complete as per specifications.( COMMON Electrical SR of 2023-24, PWD CIVIL SR CHAPTER-1 ) In Hard Soil. Ic, 50 x 0.60 x 0.60 =18.00 cmt ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.Cum179.22179.2218.0FalseNoneNoneFalseNoneFalse3225.960
3138116107848NoneITEM NO 21.06,VOL 6Laying of cable in existing Trench / GI Pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminium Rollers as directed by the departmental staff,. LT Cable -35 to 95 Sqmm Labour charges Rs, 45 % Locality charges Rs. ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.Km45151.5545151.550.1FalseNoneNoneFalseNoneFalse4515.1550
3138117107848NoneITEM NO 48.07,VOL 6GI Pipe B-Class as per IS 1239,. GI Pipe -65 mm Dia Materials cost Rs. ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.Mtr464.0464.014.0FalseNoneNoneFalseNoneFalse6496.00
3138118107848NoneITEM NO 63.06,VOL 6Supplying of Cable gland ,.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) ) 40 mm Materials cost Rs. ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.No148.0148.04.0FalseNoneNoneFalseNoneFalse592.00
3138119107848NoneITEM NO59.01,VOL 6Supplying of Haevy Duty Copper Terminal Long Barrel,. 2Sqmm Copper Terminal, Apprx Wt: 11 Gm Materials cost Rs. ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.No27.027.04.0FalseNoneNoneFalseNoneFalse108.00
3138120107848NoneITEM NO 59.03,VOL 650 Sqmm Copper Terminal, Apprx Wt: 26 Gm ---- including cost and conveyance of all materials all lead and lift, loading and unloading, hire charges of machinery and equipments, transportation charges labour charges and all other incidental charges etc., complete as per standard technical detailed specification and as per approved design and drawing and directions of the Engineer in charge of the work.No58.058.012.0FalseNoneNoneFalseNoneFalse696.00
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17158561460000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17158561460000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17158561460000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17158561460000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submissionNone
17158561460000NoneNoneELIGIBILITYThe bidder is required to ensure browser compatibility of the computer well in advance to the last date and time for receipt of tenders. The departments shall not be responsible for non-accessibility of e-Procurement portal due to internet connectivity issues and technical glitches at bidders end.None
17158561460000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
17158561460000NoneNoneELIGIBILITYBidder shall pay Contract Management Module processing fees of 0.025 percent of the contact value (Min Rs.500/- and Max Rs.7500/-) soon after contract has been issued to bidder.None
17158561460000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender documentNone
17158561460000NoneNoneELIGIBILITYThe bidder shall bear all costs associated with the preparation and submission of his tender, and the employer will in no case be responsible and liable for those costs. The tender fee is non-refundable.None
17158561460000NoneNoneELIGIBILITYThe employer reserves the rights to reject one or all tenders without assigning any reason.None
17158561460000NoneNoneELIGIBILITYThe employer is not responsible for any delay in accessing E- procurement portal.None
17158561460000NoneNoneELIGIBILITYContractors should be registered with KPWD Class - III and above Registration and the tenderer should submit the Registration Certificate along with technical bid.None
17158561460000NoneNoneELIGIBILITYTo qualify for award of this contract, each tenderer should give all details and documents as per Technical and Financial bid attached to this tender.None
17158561460000NoneNoneELIGIBILITYAs per Karnataka state Government order LD/300/LET/2006 Bangalore dated 01.01.07 and Government letter no PW/134/BMS/2007 dated 27.07.07, a sum amounting to 1percent of the bill amount will be deducted towards constructions labour welfare fund.None
17158561460000NoneNoneELIGIBILITYAll the formats prescribed in the bid document shall be filled by the tenderer in complete manner otherwise it will be rejected.None
17158561460000NoneNoneELIGIBILITYAll the scanned documents pertaining to bidder to be uploaded shall be in original and same originals should be produced to the Executive Engineer (at the time of Technical Bid Opening) who reserves right to verify the original documents before approval.None
17158561460000NoneNoneELIGIBILITYContractors should follow strictly prevailing rules of labour act.None
17158561460000NoneNoneELIGIBILITYThe Item rates quoted shall include cost of Royalty charges on construction materials and other taxes as per rates provided in prevailing Govt orders at the time of execution and including cost and conveyance of all materials curing, loading and unloading with all lead and lifts, labour, hire charges of machineries and equipment etc., complete and all other incidental charges. All the items shall be executed as directed by the Engineer-in-charge of the work.None
17158561460000NoneNoneELIGIBILITYAll materials required for this work shall be procured by the bidder himself and should be got tested by the quality control authorities at his own cost before use on the work. Department will not supply any materials.None
17158561460000NoneNoneELIGIBILITYThe tenderer should submit proposed methodology and programme of construction backed with equipment and material planning, & deployment duly supported with broad calculation and quality management , plan, proposed to be adopted justifying their capability of execution and completion of the work as per technical specifications and within the stipulated period of completion.None
17158561460000NoneNoneELIGIBILITYMaterials like bitumen, steel,cement etc., required for the work shall be procured by the tenderer themselves and should get tested by the quality control authority at his cost before used on the work.None
17158561460000NoneNoneELIGIBILITYPERFORMANCE SECURITY: The successful tenderer shall furnish Performance Security Deposit (Achievement Guarantee) at 5 percent of the amount put to tender within 20 days after approve of tender as per rule 29.5 of the tender and clause 44 of the agreement in the form of cash/Bankers Cheque, D.D, Pay order Bank Guarantee or N.S.Cs, duly pledged in the nature of EXECUTIVE ENGINEER, PWD Mangalore Div.None
17158561460000NoneNoneELIGIBILITYAll documents should be uploaded by the contractor is to be attested by the authorized notary or not below the rank of Executive Engineer and should be produced for verification at any stage of process as and when sought for .Failure to produce original documents leads to rejection of Tender.None
17158561460000NoneNoneELIGIBILITYFinancial Year will be reckoned as the period between first day of April and Thirty-first day of March of succeeding year (both days inclusive).None
17158561460000NoneNoneELIGIBILITYAll safety precautions, warning signs, night illumination, reflectors, deployment of security guards has to be ensured so that no untoward incident happens on account of negligence or any project activity. Contractor should indemnify the client to that extent.None
17158561460000NoneNoneELIGIBILITYUnits, Rates and Prices shall be quoted by the tender in Indian Rupees onlyNone
17158561460000NoneNoneELIGIBILITYFurther particulars, if any, required by the Contractor can be had from the office of the Executive Engineer PWD Division Mangalore, during office hours on all working days. It may be noted that if any of the dates mentioned above happened to be a general holiday the next working day will hold good in lieu of the dates mentioned.None
17158561460000NoneNoneELIGIBILITYItem for which no rates or price has been entered in will not be paid for by the Employer when executed & shall be deemed covered by the other rates and prices in the bill of quantities.None
17158561460000NoneNoneELIGIBILITYThe royalty charges on construction materials will be deducted as per prevailing Govt orders.None
17158561460000NoneNoneELIGIBILITYThe Bidders shall note that the information furnished in technical Bid will be evaluated with respect to the Technical requirement Criteria set forth in the Bid Document, which is uploaded separately. The Bids meeting the minimum Technical criteria at the discretion of the Engineer-in-Charge shall only be qualified for financial Evaluation of Financial Bids.None
17158561460000NoneNoneELIGIBILITYThe field Lab shall be preferably located, adjacent to the site with the required amenities as per the clause. Failing which 1percent of the amount of work done will be penalized.None
17158561460000NoneNoneELIGIBILITYTenderer shall obtain the Work done Certificate in the prescribed format from the Competent Authority not below the rank of Executive Engineer (District Level Officer) and scan the Original Certificate and attach the scanned file to the tender. The Original Certificate shall be produced at the time of opening of Technical Bids for physical verification.None
17158561460000NoneNoneELIGIBILITYTenderers are requested to read the Bid documents carefully and upload the necessary documents before submission of their bid.None
17158561460000NoneNoneELIGIBILITYThe contractor should maintain the work during the defective liability period, i.e. up to 365 Days at his own cost.None
17158561460000NoneNoneELIGIBILITYContractors should have Registration of GST, Employers Provident Fund and tenderer should submit Registration Certificate along with technical bidNone
17158561460000NoneNoneELIGIBILITYEMD of Rs 50,000.00 shall be through Karnataka Public Procurement Portal (KPPP)and the balance of Rs 1,42,100-00 by Bank guarantee issued by Nationalised Scheduled Bank. Contractor should upload the scanned copy of Bank Guarantee issued by Nationalised/Scheduled Bank in Karnataka Public Procurement Portal (KPPP) & the original BG should produce before entering the agreement if awarded.None
17158561460000NoneNoneELIGIBILITYEstimate rates are excluding GST as per Common SR 2021-22 and prevailing GST (18percent of Amount Put to tender) amount is kept in form of Lump sum in sanctioned estimate according to guidelines in Common SR (GO:PWD 51 RDF 2019 Bangaluru Dt:18.03.2022). Therefore, amount put to Tender and ECV amount are excluding GST. KPPP-PORTAL format has No Options to add GST Separately at stage of Draft Tender Schedule Process for Over All amount put to Tender, tender has been inviting through an Option with INCLUSIVE. But the item wise rates do not include GST. Hence, GST will be paid separately for the quoted amount accordingly. Declaration Certificate must be attached mandatorily.None
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneOwning the following key and critical equipment for this work (xxxx, xxxx, xxxx)NoneNone
NoneNoneNoneNoneTotal value of civl engineering works executed and payments received in the last five years (year-wise)NoneNone
NoneNoneNoneNoneBanker Details for referenceNoneNone
NoneNoneNoneNoneConstruction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneReports on the financial standing of the tenderer, such as profit and loss statements and auditor’s reports for the last five yearsNoneNone
NoneNoneNoneNoneQualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneList of Financial Resources with CertificatesNoneNone
NoneNoneNoneNoneSection 2: ITT 3.2 - To qualify for award of this contract, each Tenderer in its name should have in the last five years (i.e. 2019-20 to 2023-2024) (b) satisfactorily completed(at least 90% of contract value), as prime contractor, at least one similar Buiding work of value not less than Rs. 48.02 LAKHS (usually not less than 50% estimated value of contract)Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Work-done certificate issued from an officer not below the rank of Executive Engineer or equivalent
NoneNoneNoneNoneSection 2 ITT 3.2c To qualify for award of this contract, each Tenderer in its name should have in the last five years (i.e. 2019-20 to 2023-2024) c) executed in any one year, the following minimum quantities of work Note Specify the principal items of works to be executed under this contract 1. Earth Work excavation/ Embankment/Filling -361.00Cum, 2. PCC/RCC - 163.00 Cum, 3.Concrete Block -392.00 Sqmt. 4. All types of flooring /Cladding/Skirting/Dadoing-186.00 Sqm 5. Plastering-1012.00 Sqm 6. TMT Steel - 14.25 TonnePast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Work-done certificate issued from an officer not below the rank of Executive Engineer or equivalent
NoneNoneNoneNoneSection 2 ITT 3.2 d) The Tenderer or his identified sub-contractor should possess required valid electrical license for executing building electrification works and should have executed similar electrical works totaling Rs 3.57 Lakhs. (usually not less than 50% of the electrical works) in any one yearPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Work-done certificate issued from an officer not below the rank of Executive Engineer or equivalent
NoneNoneNoneNoneSection 2 ITT 3.2 e)The Tenderer or his identified sub-contractor should possess valid license for executing water supply/sanitary engineering works and should have executed similar water supply/sanitary engineering works totaling Rs 1.67 Lakhs. (usually not less than 50% of the water supply/sanitary engineering works) in any one yearPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Work-done certificate issued from an officer not below the rank of Executive Engineer or equivalent
NoneNoneNoneNoneSection 2 ITT 3.3 - Each Tenderer should further demonstrate (b) Liquid assets and /or availability of credit facilities of no less than Rs. 28.81 Lakhs (Credit lines/ letter of credit/ certificates from banks for meeting the fund requirement etc.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Bankers certificate in the prescribed format issued by Nationalised Banks as per KW-4
NoneNoneNoneNoneSection 2 ITT 3.2 To qualify for award of this contract, each Tenderer in its name should have in the last five years (i.e. 2019-20 to 2023-2024) (a) achieved in at least two financial years a minimum financial turnover (in all classes of civil engineering works only) of Rs 96.04 LAKHS (usually not less than two times the estimated annual payments under this contract)Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- profit and loss statement ,Balance sheets certified from an Registered Chartered Accountant
NoneNoneNoneNoneList of existing commitments and ongoing worksFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- List of existing commitments and ongoing works
NoneNoneNoneNoneList of works for which tenders already submittedFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- List of works for which tenders already submitted
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Annual Turnover Certificate along with profit & loss statement Certificate countersigned from Chartered AccountantTrueTechnical Bid
KPWD REGISTRATION CERTIFICATE CLASS III & ABOVETrueTechnical Bid
Assessed available tender capacityTrueTechnical Bid
Workdone CertificateTrueTechnical Bid
List of existing commitments and ongoing workTrueTechnical Bid
tenderWorkLocationList
tenderAddressNone
tenderRecallDTONone