| tenderSubEstimateList | | createdTs | version | createdDate | modifiedDate | workCategoryName | subEstimateName | estimateTotal | itemList |
|---|
| 1718185432000 | 0 | None | None | Buildings | MAIN BUILDING ABSTRACT | 77081689.2 | | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
|---|
| 3276916 | 113718 | None | code01 | Vol 1 Common SR for Engineering Departments-23-24) Earth work in surface excavation for stripping, seating of bund, Road way, by manual means for lowering & leveling the ground for all works other than foundation & depth in all kinds of soil not exceeding 300mm as per drawing and technical specifications, including setting out, shoring strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other | Sqm | 102.0 | 102.0 | 2659.21 | False | None | None | False | None | False | 271239.42 | 0 | | 3276917 | 113718 | None | code02 | Vol 1 Common SR for Engineering Departments - 23-24) Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m (Page 5, Specification 1.4.1)Note: Cost of De-watering upto 5 % may be added, where required assessment for dewatering shall be made as per site condition | Cum | 271.0 | 271.0 | 1059.13 | False | None | None | False | None | False | 287024.23 | 0 | | 3276918 | 113718 | None | code03 | Vol 1 Common SR for Engineering Departments - 23-24) Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth exceeding 1.5m, but not exceeding 3 m (Page 5, Specification 1.4.2) Cost of De-watering upto 10 % may be added , where required assessment for dewatering shall be made as per site condition | Cum | 290.0 | 290.0 | 424.44 | False | None | None | False | None | False | 123087.6 | 0 | | 3276919 | 113718 | None | code04 | Vol 1 Common SR for Engineering Departments - 23-24) Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. (Page 7, Specification 1.9) | Sqm | 263.0 | 263.0 | 1483.57 | False | None | None | False | None | False | 390178.91 | 0 | | 3276920 | 113718 | None | code05 | Vol-2 Uni SR 2023-24 Building) Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications. (Page 5, Specification 4.1) | Cum | 132.0 | 132.0 | 1791.14 | False | None | None | False | None | False | 236430.48 | 0 | | 3276921 | 113718 | None | code06 | Vol 1 Common SR for Engineering Departments - 23-24) Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. In all kinds of soils depth upto 3 m (Page 8, Specification 1.14.1) | Cum | 114.0 | 114.0 | 1332.35 | False | None | None | False | None | False | 151887.9 | 0 | | 3276922 | 113718 | None | code07 | Vol 1 Common SR for Engineering Departments - 23-24) Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes ma chine mixed, laid in layers not exceeding 150 mm thickness, well com pacted using plate vibrators, including all lead & lifts, cost of all materi als of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates (Page 15, Specification 2.1.2) | Cum | 6532.0 | 6532.0 | 233.68 | False | None | None | False | None | False | 1526397.76 | 0 | | 3276923 | 113718 | None | code08 | Vol 1 Common SR for Engineering Departments - 23-24) Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates (Page 15, Specification 2.1.4) | Cum | 7200.0 | 7200.0 | 0.51 | False | None | None | False | None | False | 3672.0 | 0 | | 3276924 | 113718 | None | code09 | Ground Floor windows / ventilator sills | Cum | 7272.0 | 7272.0 | 0.76 | False | None | None | False | None | False | 5526.72 | 0 | | 3276925 | 113718 | None | code10 | First Floor windows / ventilator sills | Cum | 7345.0 | 7345.0 | 1.0 | False | None | None | False | None | False | 7345.0 | 0 | | 3276926 | 113718 | None | code11 | Mezanine Floor windows / ventilator sills | Cum | 7417.0 | 7417.0 | 0.5 | False | None | None | False | None | False | 3708.5 | 0 | | 3276927 | 113718 | None | code12 | Vol 1 Common SR for Engineering Departments - 23-24) Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates and including formwork (Page 15, Specification 2.2.2.1, Appendix 1, page 29,30) | Cum | 7867.0 | 7867.0 | 403.02 | False | None | None | False | None | False | 3170558.34 | 0 | | 3276928 | 113718 | None | code13 | Vol 1 Common SR for Engineering Departments - 23-24) Providing and laying in position Reinforced cement concrete for all Column works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates and including formwork (Page 17, Specification 2.5.2 Appendix 1, page 29,30) | Cum | 12904.0 | 12904.0 | 73.66 | False | None | None | False | None | False | 950508.64 | 0 | | 3276929 | 113718 | None | code14 | First Floor | Cum | 13032.0 | 13032.0 | 32.76 | False | None | None | False | None | False | 426928.32 | 0 | | 3276930 | 113718 | None | code15 | Mezannine Floor | Cum | 13161.0 | 13161.0 | 32.76 | False | None | None | False | None | False | 431154.36 | 0 | | 3276931 | 113718 | None | code16 | Vol 1 Common SR for Engineering Departments - 23-24) Providing and laying in position Reinforced cement concrete for all Lintels works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates and including formwork (Page 17, Specification 2.5.2 Appendix 1, page 29,30) | Cum | 12904.0 | 12904.0 | 4.37 | False | None | None | False | None | False | 56390.48 | 0 | | 3276932 | 113718 | None | code17 | Ground Floor | Cum | 13032.0 | 13032.0 | 24.95 | False | None | None | False | None | False | 325148.4 | 0 | | 3276933 | 113718 | None | code18 | First Floor | Cum | 13161.0 | 13161.0 | 22.25 | False | None | None | False | None | False | 292832.25 | 0 | | 3276934 | 113718 | None | code19 | Mezannine Floor | Cum | 13291.0 | 13291.0 | 22.18 | False | None | None | False | None | False | 294794.38 | 0 | | 3276935 | 113718 | None | code20 | Vol 1 Common SR for Engineering Departments - 23-24) Providing and laying in position Reinforced cement concrete for all Chejjas and Lofts works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates and including formwork (Page 17, Specification 2.5.2 Appendix 1, page 29,30) | Cum | 11006.0 | 11006.0 | 0.76 | False | None | None | False | None | False | 8364.56 | 0 | | 3276936 | 113718 | None | code21 | Ground Floor | Cum | 11116.0 | 11116.0 | 1.75 | False | None | None | False | None | False | 19453.0 | 0 | | 3276937 | 113718 | None | code22 | First Floor | Cum | 11227.0 | 11227.0 | 20.34 | False | None | None | False | None | False | 228357.18 | 0 | | 3276938 | 113718 | None | code23 | Vol 1 Common SR for Engineering Departments - 23-24) Providing and laying in position Reinforced cement concrete for all Beam works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates and including formwork (Page 17, Specification 2.5.2 Appendix 1, page 29,30) | Cum | 12144.0 | 12144.0 | 62.37 | False | None | None | False | None | False | 757421.28 | 0 | | 3276939 | 113718 | None | code24 | First Floor | Cum | 12266.0 | 12266.0 | 126.42 | False | None | None | False | None | False | 1550667.72 | 0 | | 3276940 | 113718 | None | code25 | Mezannine Floor | Cum | 12387.0 | 12387.0 | 60.78 | False | None | None | False | None | False | 752881.86 | 0 | | 3276941 | 113718 | None | code26 | Vol 1 Common SR for Engineering Departments - 23-24) Providing and laying in position Reinforced cement concrete for all Slab works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates and including formwork (Page 17, Specification 2.5.2 Appendix 1, page 29,30) | Cum | 11386.0 | 11386.0 | 35.22 | False | None | None | False | None | False | 401014.92 | 0 | | 3276942 | 113718 | None | code27 | First Floor | Cum | 11499.0 | 11499.0 | 216.45 | False | None | None | False | None | False | 2488958.55 | 0 | | 3276943 | 113718 | None | code28 | Mezannine Floor | Cum | 11613.0 | 11613.0 | 91.1 | False | None | None | False | None | False | 1057944.3 | 0 | | 3276944 | 113718 | None | code29 | Vol 1 Common SR for Engineering Departments - 23-24) Providing and laying in position Reinforced cement concrete for all Stairs works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates and including formwork (Page 17, Specification 2.5.2 Appendix 1, page 29,30) | Cum | 11386.0 | 11386.0 | 4.98 | False | None | None | False | None | False | 56702.28 | 0 | | 3276945 | 113718 | None | code30 | Ground Floor | Cum | 11499.0 | 11499.0 | 20.54 | False | None | None | False | None | False | 236189.46 | 0 | | 3276946 | 113718 | None | code31 | First Floor | Cum | 11613.0 | 11613.0 | 17.77 | False | None | None | False | None | False | 206363.01 | 0 | | 3276947 | 113718 | None | code32 | Mezanine Floor | Cum | 11726.0 | 11726.0 | 17.72 | False | None | None | False | None | False | 207784.72 | 0 | | 3276948 | 113718 | None | code33 | Vol 1 Common SR for Engineering Departments - 23-24) Providing and laying in position Reinforced cement concrete for all Retaining wall works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates and including formwork (Page 17, Specification 2.5.2 Appendix 1, page 29,30) | Cum | 11386.0 | 11386.0 | 97.43 | False | None | None | False | None | False | 1109337.98 | 0 | | 3276949 | 113718 | None | code34 | Vol-2 Uni SR 2023-24 Building) Providing and constructing laterite size stone masonry including cost and conveyance of all materials curing etc complete as per specification I.S. 3620/1979 having compressive strength not less than 3.5 N/mm2 for saturated dry samples - For Super structure in CM 1:6. (Page 9 - specification 5.7) | Cum | 7566.0 | 7566.0 | 21.33 | False | None | None | False | None | False | 161382.78 | 0 | | 3276950 | 113718 | None | code35 | Ground Floor | Cum | 7642.0 | 7642.0 | 160.02 | False | None | None | False | None | False | 1222872.84 | 0 | | 3276951 | 113718 | None | code36 | Vol-2 Uni SR 2023-24 Building) Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications (Page 17, Specification 6.32) | Sqm | 1467.0 | 1467.0 | 542.34 | False | None | None | False | None | False | 795612.78 | 0 | | 3276952 | 113718 | None | code37 | Mezanine Floor | Sqm | 1482.0 | 1482.0 | 592.96 | False | None | None | False | None | False | 878766.72 | 0 | | 3276953 | 113718 | None | code38 | Vol-2 Uni SR 2023-24 Building) Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications (Page 17, Specification 6.34) | Sqm | 1236.0 | 1236.0 | 4.2 | False | None | None | False | None | False | 5191.2 | 0 | | 3276954 | 113718 | None | code39 | Ground Floor | Sqm | 1249.0 | 1249.0 | 89.11 | False | None | None | False | None | False | 111298.39 | 0 | | 3276955 | 113718 | None | code40 | First Floor | Sqm | 1261.0 | 1261.0 | 47.02 | False | None | None | False | None | False | 59292.22 | 0 | | 3276956 | 113718 | None | code41 | Mezanine Floor | Sqm | 1273.0 | 1273.0 | 10.5 | False | None | None | False | None | False | 13366.5 | 0 | | 3276957 | 113718 | None | code42 | Vol-1 Uni SR 2023-24 Building) Supplying fitting and placing TMT FE 550 / 550D steel reinforcement including cost of all materials, machinery, labour, cleaning, staightening, cutting, bending, hooking, laping / welding joints, tying with bining wire, / soft annealed steel wire and other ancilary operations complete as per drawing and techinical specification - Buildings (Page 18, Specification 2.11a.) | MT | 100192.0 | 100192.0 | 130.0 | False | None | None | False | None | False | 13024960.0 | 0 | | 3276958 | 113718 | None | code43 | Vol-2 Uni SR 2023-24 Building) Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete, fixed to openings with rawl plugs screws etc. using 10mm square rods @ approximate 5"c/c, outer frame with 1 1/4"x1/4" MS angle and including one coat metallic primer.(Weight per Sft not more than 1.5Kgs) as per approved design (Page 86, Specification 11.34B) | Kgs | 205.0 | 205.0 | 3268.9 | False | None | None | False | None | False | 670124.5 | 0 | | 3276959 | 113718 | None | code47 | Vol-2 Uni SR 2023-24 Building) Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. Extra for providing mechanical device chain and crank operation for operating rolling shutters: Exceeding 16.80 m² in area including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge (Page 78 Specification 11.6.1 & 11.8.2) | Sqm | 4069.0 | 4069.0 | 52.2 | False | None | None | False | None | False | 212401.8 | 0 | | 3276960 | 113718 | None | code48 | Basement Floor | Kgs | 205.0 | 205.0 | 612.0 | False | None | None | False | None | False | 125460.0 | 0 | | 3276961 | 113718 | None | code49 | Ground Floor | Kgs | 207.0 | 207.0 | 1376.0 | False | None | None | False | None | False | 284832.0 | 0 | | 3276962 | 113718 | None | code50 | First Floor | Kgs | 209.0 | 209.0 | 4053.0 | False | None | None | False | None | False | 847077.0 | 0 | | 3276963 | 113718 | None | code51 | Mezanine Floor | Kgs | 211.0 | 211.0 | 4034.0 | False | None | None | False | None | False | 851174.0 | 0 | | 3276964 | 113718 | None | code52 | Vol-2 Uni SR 2023-24 Building) Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (Page 82 Specification 11.16.2) | Kgs | 165.0 | 165.0 | 51167.0 | False | None | None | False | None | False | 8442555.0 | 0 | | 3276965 | 113718 | None | code53 | Vol-2 Uni SR 2023-24 Building) Providing,fabricating and fixing Profiled Poly Urethane insulated Roof(PUF Sheet) having modular density 40kg/m2 and size 1.06m width and upto 7.60m length, 30mm thick sheets roof having external sheet of 0.5mm steel, bottom sheet of 0.40mm steel with powder coated finish. The precoated sheet shall be of minimum 240MPa steel conforming to IS 14246 : 1995 and shal have zinc coating with minimum 120gsm as per IS 277:1992,.The roofing system shall have suitable water proof over lapping arrangments and GRIHA ceritifed.The fasting shall be of self tapping screws of required length with PVC head along with washer pre-painted aluminium cap unit with build in seal arrangments. The entire roof shall be firmly fastened to the existng frame including all lead and lifts, loading & unloading ,usage charges of machinery and equipments, transportation charges,labour charges and all other incidental charges etc.,complete as per standard technical detailed specifications and as directed by the Engineer in charge. (Page 38 Specification 11.67.1) | Sqm | 2462.0 | 2462.0 | 2376.56 | False | None | None | False | None | False | 5851090.72 | 0 | | 3276966 | 113718 | None | code54 | Vol-2 Uni SR 2023-24 Building) Extra for providing Manually operated Bevel Gear Box for operating rolling shutters including cost of materials, labour,usage charges of machinery complete as per specifications and as per directions of the Engineer-in Charge. (Page 79 Specification 11.8.3) | Each | 3456.0 | 3456.0 | 3.0 | False | None | None | False | None | False | 10368.0 | 0 | | 3276967 | 113718 | None | code55 | Vol-2 Uni SR 2023-24 Building) Providing Mathi/Nandi wood frames of doors, windows, clerestory windows, ventilators and other frames, (size 150mm x 75mm commercial sizes),wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications. (Page 99 Specification 12.12) | Cum | 139106.0 | 139106.0 | 0.47 | False | None | None | False | None | False | 65379.82 | 0 | | 3276968 | 113718 | None | code56 | Ground Floor | Cum | 139106.0 | 139106.0 | 1.56 | False | None | None | False | None | False | 217005.36 | 0 | | 3276969 | 113718 | None | code57 | First Floor | Cum | 139106.0 | 139106.0 | 1.18 | False | None | None | False | None | False | 164145.08 | 0 | | 3276970 | 113718 | None | code58 | Mezanine Floor | Cum | 139106.0 | 139106.0 | 1.33 | False | None | None | False | None | False | 185010.98 | 0 | | 3276971 | 113718 | None | code59 | Vol-2 Uni SR 2023-24 Building) Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemically treated hard wood battens and internal frame with minimum 45 mm wide wooden frame all round door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door using liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per specification 35 mm thick both side commercial (Page 105 Specification 12.57.6) | Sqm | 3721.0 | 3721.0 | 8.4 | False | None | None | False | None | False | 31256.4 | 0 | | 3276972 | 113718 | None | code60 | Ground Floor | Sqm | 3721.0 | 3721.0 | 37.8 | False | None | None | False | None | False | 140653.8 | 0 | | 3276973 | 113718 | None | code61 | First Floor | Sqm | 3721.0 | 3721.0 | 8.4 | False | None | None | False | None | False | 31256.4 | 0 | | 3276974 | 113718 | None | code62 | Mezanine Floor | Sqm | 3721.0 | 3721.0 | 12.6 | False | None | None | False | None | False | 46884.6 | 0 | | 3276975 | 113718 | None | code63 | Vol-2 Uni SR 2023-24 Building) Providing and fixing in position fully panelled Honne wood shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. ( excluding cost of fixtures ) (Page 100 Specification 12.17) | Sqm | 7935.0 | 7935.0 | 37.8 | False | None | None | False | None | False | 299943.0 | 0 | | 3276976 | 113718 | None | code64 | First Floor | Sqm | 7935.0 | 7935.0 | 44.1 | False | None | None | False | None | False | 349933.5 | 0 | | 3276977 | 113718 | None | code65 | Mezanine Floor | Sqm | 7935.0 | 7935.0 | 56.7 | False | None | None | False | None | False | 449914.5 | 0 | | 3276978 | 113718 | None | code66 | Ground Floor | Sqm | 7542.0 | 7542.0 | 28.8 | False | None | None | False | None | False | 217209.6 | 0 | | 3276979 | 113718 | None | code67 | First Floor | Sqm | 7542.0 | 7542.0 | 66.06 | False | None | None | False | None | False | 498224.52 | 0 | | 3276980 | 113718 | None | code68 | Mezanine Floor | Sqm | 7542.0 | 7542.0 | 10.8 | False | None | None | False | None | False | 81453.6 | 0 | | 3276981 | 113718 | None | code69 | Vol-2 Uni SR 2023-24 Building) Providing& fixing of Openable window made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPV(Thermo Plastic Vulcanized) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the openable frame. The frame having overall size of 60mm x 55mm with GI reinforcement of 1mm thickness and openable sash with overall size of 60mm x 75mm and GI reinforcement of 1.5mm thickness. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 34 mm. Windows shall be provided with 5mm plain float glass, Standard hardware with friction hinge & Multi point locking system with Handle. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size -900mm x 1819mm. (The cost is inclusive of all fixtures and separate charges for minor T&Ps shall not be made) (Page 112 Specification 12.91) | Sqm | 6789.0 | 6789.0 | 6.57 | False | None | None | False | None | False | 44603.73 | 0 | | 3276982 | 113718 | None | code70 | Ground Floor | Sqm | 6858.0 | 6858.0 | 15.6 | False | None | None | False | None | False | 106984.8 | 0 | | 3276983 | 113718 | None | code71 | First Floor | Sqm | 6925.0 | 6925.0 | 13.2 | False | None | None | False | None | False | 91410.0 | 0 | | 3276984 | 113718 | None | code72 | Mezanine Floor | Sqm | 7060.0 | 7060.0 | 10.8 | False | None | None | False | None | False | 76248.0 | 0 | | 3276985 | 113718 | None | code73 | Vol-2 Uni SR 2023-24 Building) Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (Page 42, Specification 8.9) | Sqm | 431.0 | 431.0 | 303.61 | False | None | None | False | None | False | 130855.91 | 0 | | 3276986 | 113718 | None | code74 | Ground Floor | Sqm | 436.0 | 436.0 | 2356.72 | False | None | None | False | None | False | 1027529.92 | 0 | | 3276987 | 113718 | None | code75 | First Floor | Sqm | 440.0 | 440.0 | 1099.19 | False | None | None | False | None | False | 483643.6 | 0 | | 3276988 | 113718 | None | code76 | Vol-2 Uni SR 2023-24 Building) Providing 20 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick/ stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge (Page 42, Specification 8.6.2) | Sqm | 480.0 | 480.0 | 645.27 | False | None | None | False | None | False | 309729.6 | 0 | | 3276989 | 113718 | None | code77 | Ground Floor | Sqm | 485.0 | 485.0 | 2074.68 | False | None | None | False | None | False | 1006219.8 | 0 | | 3276990 | 113718 | None | code78 | First Floor | Sqm | 491.0 | 491.0 | 1713.57 | False | None | None | False | None | False | 841362.87 | 0 | | 3276991 | 113718 | None | code79 | Mezanine Floor | Sqm | 495.0 | 495.0 | 1771.56 | False | None | None | False | None | False | 876922.2 | 0 | | 3276992 | 113718 | None | code80 | Vol-2 Uni SR 2023-24 Building) Providing 20 mm external cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick/stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (Page 42, Specification 8.6.2) | Sqm | 480.0 | 480.0 | 235.55 | False | None | None | False | None | False | 113064.0 | 0 | | 3276993 | 113718 | None | code81 | Ground Floor | Sqm | 485.0 | 485.0 | 330.11 | False | None | None | False | None | False | 160103.35 | 0 | | 3276994 | 113718 | None | code82 | First Floor and Mezanine Floor' | Sqm | 491.0 | 491.0 | 1118.97 | False | None | None | False | None | False | 549414.27 | 0 | | 3276995 | 113718 | None | code83 | Vol-2 Uni SR 2023-24 Building) Providing Flush/ Ruled pointing: Pointing on stone work with cement mortar 1:3 (1 cement : 3 fine sand) after raking joints to depth nicely lin ing, including cost of materials, labour, curing as per specifications and as per directions of Engineer-in-charge (Page 44, Specification 8.19.1) | Sqm | 286.0 | 286.0 | 279.18 | False | None | None | False | None | False | 79845.48 | 0 | | 3276996 | 113718 | None | code84 | Ground Floor | Sqm | 286.0 | 286.0 | 800.1 | False | None | None | False | None | False | 228828.6 | 0 | | 3276997 | 113718 | None | code85 | Vol-2 Uni SR 2023-24 Building) Providing and laying Vitrified tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 1000x1200 mm (Page 61, Specification 9.17.4) | Sqm | 2088.0 | 2088.0 | 129.3 | False | None | None | False | None | False | 269978.4 | 0 | | 3276998 | 113718 | None | code86 | Ground Floor | Sqm | 2109.0 | 2109.0 | 535.96 | False | None | None | False | None | False | 1130339.64 | 0 | | 3276999 | 113718 | None | code87 | First Floor | Sqm | 2129.0 | 2129.0 | 40.42 | False | None | None | False | None | False | 86054.18 | 0 | | 3277000 | 113718 | None | code88 | Mezanine Floor | Sqm | 2150.0 | 2150.0 | 100.2 | False | None | None | False | None | False | 215430.0 | 0 | | 3277001 | 113718 | None | code89 | Vol-2 Uni SR 2023-24 Building) Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications.(Page 65, Specification 9.39) | Sqm | 1623.0 | 1623.0 | 14.85 | False | None | None | False | None | False | 24101.55 | 0 | | 3277002 | 113718 | None | code90 | Ground Floor | Sqm | 1639.0 | 1639.0 | 18.28 | False | None | None | False | None | False | 29960.92 | 0 | | 3277003 | 113718 | None | code91 | First Floor | Sqm | 1655.0 | 1655.0 | 4.34 | False | None | None | False | None | False | 7182.7 | 0 | | 3277004 | 113718 | None | code92 | Mezanine Floor | Sqm | 1671.0 | 1671.0 | 9.02 | False | None | None | False | None | False | 15072.42 | 0 | | 3277005 | 113718 | None | code93 | Vol-2 Uni SR 2023-24 Building) Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thick ness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. (Page 60, Specification 9.11) | Sqm | 996.0 | 996.0 | 12.52 | False | None | None | False | None | False | 12469.92 | 0 | | 3277006 | 113718 | None | code94 | Ground Floor | Sqm | 1006.0 | 1006.0 | 53.6 | False | None | None | False | None | False | 53921.6 | 0 | | 3277007 | 113718 | None | code95 | First Floor | Sqm | 1016.0 | 1016.0 | 142.49 | False | None | None | False | None | False | 144769.84 | 0 | | 3277008 | 113718 | None | code96 | Mezanine Floor | Sqm | 1026.0 | 1026.0 | 42.94 | False | None | None | False | None | False | 44056.44 | 0 | | 3277009 | 113718 | None | code97 | Vol-2 Uni SR 2023-24 Building) Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete.(Page 61, Specification 9.17.5) | Sqm | 1505.0 | 1505.0 | 42.84 | False | None | None | False | None | False | 64474.2 | 0 | | 3277010 | 113718 | None | code98 | Ground Floor | Sqm | 1520.0 | 1520.0 | 576.85 | False | None | None | False | None | False | 876812.0 | 0 | | 3277011 | 113718 | None | code99 | First Floor | Sqm | 1536.0 | 1536.0 | 163.55 | False | None | None | False | None | False | 251212.8 | 0 | | 3277012 | 113718 | None | code100 | Mezanine Floor | Sqm | 1550.0 | 1550.0 | 134.4 | False | None | None | False | None | False | 208320.0 | 0 | | 3277013 | 113718 | None | code101 | Vol-2 Uni SR 2023-24 Building) Providing and laying Polished Sadarahalli Grey Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 20 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. (Page 64, Specification 9.3.1) | Sqm | 2335.0 | 2335.0 | 14.44 | False | None | None | False | None | False | 33717.4 | 0 | | 3277014 | 113718 | None | code102 | Ground Floor | Sqm | 2359.0 | 2359.0 | 1183.64 | False | None | None | False | None | False | 2792206.76 | 0 | | 3277015 | 113718 | None | code103 | First Floor | Sqm | 2382.0 | 2382.0 | 1597.96 | False | None | None | False | None | False | 3806340.72 | 0 | | 3277016 | 113718 | None | code104 | Mezanine Floor | Sqm | 2405.0 | 2405.0 | 592.21 | False | None | None | False | None | False | 1424265.05 | 0 | | 3277017 | 113718 | None | code105 | Vol-2 Uni SR 2023-24 Building) Providing and laying Black Lapotra Granite stone flooring in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing. and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. (Page 64, Specification 9.3.2) | Sqm | 2892.0 | 2892.0 | 4.0 | False | None | None | False | None | False | 11568.0 | 0 | | 3277018 | 113718 | None | code106 | Ground Floor | Sqm | 2921.0 | 2921.0 | 67.22 | False | None | None | False | None | False | 196349.62 | 0 | | 3277019 | 113718 | None | code107 | First Floor | Sqm | 2950.0 | 2950.0 | 57.43 | False | None | None | False | None | False | 169418.5 | 0 | | 3277020 | 113718 | None | code108 | Mezanine Floor | Sqm | 2979.0 | 2979.0 | 45.38 | False | None | None | False | None | False | 135187.02 | 0 | | 3277021 | 113718 | None | code109 | Vol-2 Uni SR 2023-24 Building) Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar loca tions of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Area of slab over 0.50 m2 (Page 69, Specification 10.1.2) | Sqm | 4409.0 | 4409.0 | 2.67 | False | None | None | False | None | False | 11772.03 | 0 | | 3277022 | 113718 | None | code110 | Ground Floor | Sqm | 4453.0 | 4453.0 | 182.77 | False | None | None | False | None | False | 813874.81 | 0 | | 3277023 | 113718 | None | code111 | First Floor | Sqm | 4498.0 | 4498.0 | 8.74 | False | None | None | False | None | False | 39312.52 | 0 | | 3277024 | 113718 | None | code112 | Mezanine Floor | Sqm | 4542.0 | 4542.0 | 7.4 | False | None | None | False | None | False | 33610.8 | 0 | | 3277025 | 113718 | None | code113 | Vol-2 Uni SR 2023-24 Building) Providing edge moulding to 18mm thick Granite stone counters, vanities etc including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-charge. (Page 69, Specification 10.2) | Mtr | 367.0 | 367.0 | 34.1 | False | None | None | False | None | False | 12514.7 | 0 | | 3277026 | 113718 | None | code114 | Ground Floor | Mtr | 371.0 | 371.0 | 460.0 | False | None | None | False | None | False | 170660.0 | 0 | | 3277027 | 113718 | None | code115 | First Floor | Mtr | 375.0 | 375.0 | 110.8 | False | None | None | False | None | False | 41550.0 | 0 | | 3277028 | 113718 | None | code116 | Mezanine Floor | Mtr | 379.0 | 379.0 | 110.6 | False | None | None | False | None | False | 41917.4 | 0 | | 3277029 | 113718 | None | code117 | Providing and fixing approved quality and design terracotta jali with tile adhesive and matching joint colours, including erection and removal of necessary scaffolding | Mtr | 1941.0 | 1941.0 | 315.56 | False | None | None | False | None | False | 612501.96 | 0 | | 3277030 | 113718 | None | code118 | Vol-2 Uni SR 2023-24 Building) Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. (Page 62, Specification 9.20.4) | Mtr | 129.0 | 129.0 | 236.0 | False | None | None | False | None | False | 30444.0 | 0 | | 3277031 | 113718 | None | code119 | Ground Floor | Sqm | 130.0 | 130.0 | 536.0 | False | None | None | False | None | False | 69680.0 | 0 | | 3277032 | 113718 | None | code120 | First Floor | Sqm | 131.0 | 131.0 | 40.0 | False | None | None | False | None | False | 5240.0 | 0 | | 3277033 | 113718 | None | code121 | Mezanine Floor | Sqm | 132.0 | 132.0 | 100.0 | False | None | None | False | None | False | 13200.0 | 0 | | 3277034 | 113718 | None | code122 | Vol-2 Uni SR 2023-24 Building) Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 L/10 m² over and including one coat of Special primer applied @ 0.75 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (The gloss should be 50% @ 60 degree angle with 10 years life) (Page 46, Specification 8.33.1) | Sqm | 177.0 | 177.0 | 3759.52 | False | None | None | False | None | False | 665435.04 | 0 | | 3277035 | 113718 | None | code123 | Vol-2 Uni SR 2023-24 Building) Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Special primer applied @ 0.75 ltr /10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (Page 46, Specification 8.33.1) | Sqm | 177.0 | 177.0 | 5421.84 | False | None | None | False | None | False | 959665.68 | 0 | | 3277036 | 113718 | None | code124 | Vol-2 Uni SR 2023-24 Building) Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 L/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (Page 45 Specification 8.29) | Sqm | 317.0 | 317.0 | 2820.65 | False | None | None | False | None | False | 894146.05 | 0 | | 3277037 | 113718 | None | code125 | Vol-2 Uni SR 2023-24 Building) Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90L/10 m² over an under coat of primer applied @ 0.80 L/10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (Page 47 Specification 8.33.3) | Sqm | 156.0 | 156.0 | 366.93 | False | None | None | False | None | False | 57241.08 | 0 | | 3277038 | 113718 | None | code126 | Vol-2 Uni SR 2023-24 Building) Painting wood work with Deluxe Multi Surface Paint of required shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @0.75 ltr/10 m² of approved brand and manufacture to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge (Page 47 Specification 8.33.3) | Sqm | 156.0 | 156.0 | 619.2 | False | None | None | False | None | False | 96595.2 | 0 |
| | 1718185432000 | 0 | None | None | Buildings | MAIN BUILDING ELECTRICAL | 4920993.0 | | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
|---|
| 3277039 | 113719 | None | cod1 | 19/20 mm dia 2 mm thick (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume - 6, Clause 1.2.1) | Mtr | 66.0 | 66.0 | 650.0 | False | None | None | False | None | False | 42900.0 | 0 | | 3277040 | 113719 | None | cod2 | 25 mm dia 2 mm thick (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume - 6, Clause 1.2.2) | Mtr | 78.0 | 78.0 | 600.0 | False | None | None | False | None | False | 46800.0 | 0 | | 3277041 | 113719 | None | cod3 | 32 mm dia 2.5 mm thick (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume -6, Clause 1.2.3) | Mtr | 103.0 | 103.0 | 800.0 | False | None | None | False | None | False | 82400.0 | 0 | | 3277042 | 113719 | None | cod4 | 40 mm dia 2.5 mm thick (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume -6, Clause 1.2.4) | Mtr | 147.0 | 147.0 | 600.0 | False | None | None | False | None | False | 88200.0 | 0 | | 3277043 | 113719 | None | cod5 | 19/20 mm dia 2 mm thick (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume -6, Clause 1.3.1) | Mtr | 68.0 | 68.0 | 1400.0 | False | None | None | False | None | False | 95200.0 | 0 | | 3277044 | 113719 | None | cod6 | 25 mm dia 2 mm thick (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume - 6, Clause 1.3.2) | Mtr | 79.0 | 79.0 | 1300.0 | False | None | None | False | None | False | 102700.0 | 0 | | 3277045 | 113719 | None | cod7 | 32 mm dia 2.5 mm thick (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume -6, Clause 1.3.3) | Mtr | 99.0 | 99.0 | 850.0 | False | None | None | False | None | False | 84150.0 | 0 | | 3277046 | 113719 | None | cod8 | 40 mm dia 2.5 mm thick (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume- 6, Clause 1.3.4) | Mtr | 139.0 | 139.0 | 200.0 | False | None | None | False | None | False | 27800.0 | 0 | | 3277047 | 113719 | None | cod9 | 75 x 75 x 65 mm (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume -6, Clause 1.4.1) | Each | 106.0 | 106.0 | 80.0 | False | None | None | False | None | False | 8480.0 | 0 | | 3277048 | 113719 | None | cod10 | 100 x 75 x 65 mm (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume -6, Clause 1.4.2) | Each | 118.0 | 118.0 | 50.0 | False | None | None | False | None | False | 5900.0 | 0 | | 3277049 | 113719 | None | cod11 | 135 x 75 x 65 mm (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume -6, Clause 1.4.3) | Each | 139.0 | 139.0 | 45.0 | False | None | None | False | None | False | 6255.0 | 0 | | 3277050 | 113719 | None | cod12 | 180 x 90 x 65 mm (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume - 6, Clause 1.4.4) | Each | 161.0 | 161.0 | 80.0 | False | None | None | False | None | False | 12880.0 | 0 | | 3277051 | 113719 | None | cod13 | 200 x 90 x 65 mm (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume - 6, Clause 1.4.5) | Each | 179.0 | 179.0 | 30.0 | False | None | None | False | None | False | 5370.0 | 0 | | 3277052 | 113719 | None | cod14 | 135 x 160 x 65 mm (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume - 6, Clause 1.4.6) | Each | 215.0 | 215.0 | 20.0 | False | None | None | False | None | False | 4300.0 | 0 | | 3277053 | 113719 | None | cod15 | 200 x 200 x 65 mm (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume - 6, Clause 1.4.7) | Each | 348.0 | 348.0 | 16.0 | False | None | None | False | None | False | 5568.0 | 0 | | 3277054 | 113719 | None | cod16 | 19/20 mm deep Junction box (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume -6, Clause 1.5.1) | Each | 49.0 | 49.0 | 500.0 | False | None | None | False | None | False | 24500.0 | 0 | | 3277055 | 113719 | None | cod17 | 25 mm deep Junction box (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume - 6, Clause 1.5.2) | Each | 56.0 | 56.0 | 300.0 | False | None | None | False | None | False | 16800.0 | 0 | | 3277056 | 113719 | None | cod18 | 32 mm deep Junction box (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6, Clause 1.5.3) | Each | 61.0 | 61.0 | 250.0 | False | None | None | False | None | False | 15250.0 | 0 | | 3277057 | 113719 | None | cod19 | upto 50 mm conduit in brick wall (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6, Clause 1.7.1) | Mtr | 29.0 | 29.0 | 50.0 | False | None | None | False | None | False | 1450.0 | 0 | | 3277058 | 113719 | None | cod20 | upto 50 mm conduit CC floor (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6, Clause 1.7.2) | Mtr | 66.0 | 66.0 | 40.0 | False | None | None | False | None | False | 2640.0 | 0 | | 3277059 | 113719 | None | cod21 | Supplying And Fixing "S" Hook made out of 14 mm dia M.S. Rod. (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6, Clause 1.11) | Each | 52.0 | 52.0 | 50.0 | False | None | None | False | None | False | 2600.0 | 0 | | 3277060 | 113719 | None | cod22 | Supplying And Fixing M.S. Rafter Clamp Set made out of M.S. Flat & 14 mm M.S. rod (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6, Clause 1.12) | Each | 160.0 | 160.0 | 100.0 | False | None | None | False | None | False | 16000.0 | 0 | | 3277061 | 113719 | None | cod23 | Supplying And Fixing Metal Fan Box with Round Hook (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6, Clause 1.13) | Each | 117.0 | 117.0 | 40.0 | False | None | None | False | None | False | 4680.0 | 0 | | 3277062 | 113719 | None | cod24 | Short point upto 3m from tapping point to out let via switch box (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6, Clause 2.1.2) | Each | 285.0 | 285.0 | 220.0 | False | None | None | False | None | False | 62700.0 | 0 | | 3277063 | 113719 | None | cod25 | Medium point above 3m upto 6m from tapping point to out let via switch box (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6, Clause 2.2.2) | Each | 394.0 | 394.0 | 340.0 | False | None | None | False | None | False | 133960.0 | 0 | | 3277064 | 113719 | None | cod26 | Long point above 6m upto 10m from tapping point to out let via switch (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6, Clause 2.1.3) | Each | 570.0 | 570.0 | 140.0 | False | None | None | False | None | False | 79800.0 | 0 | | 3277065 | 113719 | None | cod27 | Two outlet in a row, above 3m upto 6m from tapping point to out let via switches (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6, Clause 2.1.4) | Each | 708.0 | 708.0 | 20.0 | False | None | None | False | None | False | 14160.0 | 0 | | 3277066 | 113719 | None | cod28 | Three outlet in a row, above 6m upto 10m from tapping point to out let via switches box (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6, Clause 2.1.5) | Each | 1035.0 | 1035.0 | 10.0 | False | None | None | False | None | False | 10350.0 | 0 | | 3277067 | 113719 | None | cod29 | 1 mm2 (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6, Clause 2.3.1) | Mtr | 19.0 | 19.0 | 4500.0 | False | None | None | False | None | False | 85500.0 | 0 | | 3277068 | 113719 | None | cod30 | 1.5 mm2 (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6, Clause 2.3.2) | Mtr | 26.0 | 26.0 | 5600.0 | False | None | None | False | None | False | 145600.0 | 0 | | 3277069 | 113719 | None | cod31 | 2.5 mm2 (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6, Clause 2.3.3) | Mtr | 42.0 | 42.0 | 12800.0 | False | None | None | False | None | False | 537600.0 | 0 | | 3277070 | 113719 | None | cod32 | 4 mm2 (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6, Clause 2.3.4) | Mtr | 63.0 | 63.0 | 4000.0 | False | None | None | False | None | False | 252000.0 | 0 | | 3277071 | 113719 | None | cod33 | 6 mm2 (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6, Clause 2.3.5) | Mtr | 92.0 | 92.0 | 2000.0 | False | None | None | False | None | False | 184000.0 | 0 | | 3277072 | 113719 | None | cod34 | 10 mm2 (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6, Clause 2.3.6) | Mtr | 167.0 | 167.0 | 1000.0 | False | None | None | False | None | False | 167000.0 | 0 | | 3277073 | 113719 | None | cod35 | 4C x 1.5 mm2 (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6, Clause 2.5.3) | Mtr | 94.0 | 94.0 | 1200.0 | False | None | None | False | None | False | 112800.0 | 0 | | 3277074 | 113719 | None | cod36 | 3C x 2.5 mm2 (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6, Clause 2.6.1) | Mtr | 117.0 | 117.0 | 300.0 | False | None | None | False | None | False | 35100.0 | 0 | | 3277075 | 113719 | None | cod37 | 1-2 Way (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6, Clause 3.4.1) | Each | 138.0 | 138.0 | 80.0 | False | None | None | False | None | False | 11040.0 | 0 | | 3277076 | 113719 | None | cod38 | 4-5 Way (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6, Clause 3.4.3) | Each | 177.0 | 177.0 | 50.0 | False | None | None | False | None | False | 8850.0 | 0 | | 3277077 | 113719 | None | cod39 | 6 Way (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6, Clause 3.4.4) | Each | 220.0 | 220.0 | 45.0 | False | None | None | False | None | False | 9900.0 | 0 | | 3277078 | 113719 | None | cod40 | 8 Way (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6, Clause 3.4.5) | Each | 261.0 | 261.0 | 80.0 | False | None | None | False | None | False | 20880.0 | 0 | | 3277079 | 113719 | None | cod41 | 10-12 Way (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6, Clause 3.4.6) | Each | 319.0 | 319.0 | 30.0 | False | None | None | False | None | False | 9570.0 | 0 | | 3277080 | 113719 | None | cod42 | 16 Way (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6, Clause 3.4.7) | Each | 363.0 | 363.0 | 20.0 | False | None | None | False | None | False | 7260.0 | 0 | | 3277081 | 113719 | None | cod43 | 1 to 2 Module (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6, Clause 3.5.1) | Each | 137.0 | 137.0 | 40.0 | False | None | None | False | None | False | 5480.0 | 0 | | 3277082 | 113719 | None | cod44 | 3 Module (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6, Clause 3.5.1) | Each | 161.0 | 161.0 | 40.0 | False | None | None | False | None | False | 6440.0 | 0 | | 3277083 | 113719 | None | cod45 | 4 Module (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6, Clause 3.5.2) | Each | 175.0 | 175.0 | 50.0 | False | None | None | False | None | False | 8750.0 | 0 | | 3277084 | 113719 | None | cod46 | 6 Module (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6, Clause 3.5.3) | Each | 234.0 | 234.0 | 45.0 | False | None | None | False | None | False | 10530.0 | 0 | | 3277085 | 113719 | None | cod47 | 8 Module (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6, Clause 3.5.4) | Each | 284.0 | 284.0 | 80.0 | False | None | None | False | None | False | 22720.0 | 0 | | 3277086 | 113719 | None | cod48 | 10-12 Module (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6, Clause 3.5.5) | Each | 344.0 | 344.0 | 30.0 | False | None | None | False | None | False | 10320.0 | 0 | | 3277087 | 113719 | None | cod49 | 16 Module (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6, Clause 3.5.6) | Each | 397.0 | 397.0 | 20.0 | False | None | None | False | None | False | 7940.0 | 0 | | 3277088 | 113719 | None | cod50 | 6A One Way Switch (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6, Clause 3.6.1) | Each | 102.0 | 102.0 | 650.0 | False | None | None | False | None | False | 66300.0 | 0 | | 3277089 | 113719 | None | cod51 | 6A Two Way Switch (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6, Clause 3.6.2) | Each | 166.0 | 166.0 | 40.0 | False | None | None | False | None | False | 6640.0 | 0 | | 3277090 | 113719 | None | cod52 | 6A Three Way socket (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6, Clause 3.6.3) | Each | 171.0 | 171.0 | 200.0 | False | None | None | False | None | False | 34200.0 | 0 | | 3277091 | 113719 | None | cod53 | Stepped Fan Regulator Two Module (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6, Clause 3.6.4) | Each | 357.0 | 357.0 | 120.0 | False | None | None | False | None | False | 42840.0 | 0 | | 3277092 | 113719 | None | cod54 | 400W Dimmer (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6, Clause 3.6.5) | Each | 276.0 | 276.0 | 18.0 | False | None | None | False | None | False | 4968.0 | 0 | | 3277093 | 113719 | None | cod55 | 600W Dimmer (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6, Clause 3.6.6) | Each | 329.0 | 329.0 | 12.0 | False | None | None | False | None | False | 3948.0 | 0 | | 3277094 | 113719 | None | cod56 | 16A One Way Switch (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6, Clause 3.6.7) | Each | 180.0 | 180.0 | 80.0 | False | None | None | False | None | False | 14400.0 | 0 | | 3277095 | 113719 | None | cod57 | 6A Bell Push (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6, Clause 3.6.8) | Each | 177.0 | 177.0 | 10.0 | False | None | None | False | None | False | 1770.0 | 0 | | 3277096 | 113719 | None | cod58 | 32A DP Switch (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6, Clause 3.6.9) | Each | 326.0 | 326.0 | 40.0 | False | None | None | False | None | False | 13040.0 | 0 | | 3277097 | 113719 | None | cod59 | 6/16A Universal Socket (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6, Clause 3.6.10) | Each | 236.0 | 236.0 | 80.0 | False | None | None | False | None | False | 18880.0 | 0 | | 3277098 | 113719 | None | cod60 | TV/Telephone Socket (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6, Clause 3.6.11) | Each | 156.0 | 156.0 | 60.0 | False | None | None | False | None | False | 9360.0 | 0 | | 3277099 | 113719 | None | cod61 | RJ45/I.O Outlet Cat-6 (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6, Clause 3.6.12) | Each | 337.0 | 337.0 | 40.0 | False | None | None | False | None | False | 13480.0 | 0 | | 3277100 | 113719 | None | cod62 | Supply and erection of 14 Feet Height Street Light Pole 14 Feet Height Street Light Pole on suitable cement concrete foundation with 2.5 Feet height dia 95 mm cast iron decorative round pedestal as per design weighing not less than 37Kgs, the pedestal shall be fitted with Class 'C' G.I.Pipe 7 Feet height 75 mm outer dia and 7 feet height top piece outer dia of 65 mm fixed by measure of threading/welding/coupling complete. (excluding foundation). (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6, Clause 4.3) | Each | 20600.0 | 20600.0 | 24.0 | False | None | None | False | None | False | 494400.0 | 0 | | 3277101 | 113719 | None | cod63 | upto 12.5 HP (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6, Clause 5.2.1) | Each | 7455.0 | 7455.0 | 1.0 | False | None | None | False | None | False | 7455.0 | 0 | | 3277102 | 113719 | None | cod64 | 125 A (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6, Clause 5.11.3) | Each | 10326.0 | 10326.0 | 1.0 | False | None | None | False | None | False | 10326.0 | 0 | | 3277103 | 113719 | None | cod65 | Three pole100 A 25 kA (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6, Clause 5.15.1) | Each | 6068.0 | 6068.0 | 4.0 | False | None | None | False | None | False | 24272.0 | 0 | | 3277104 | 113719 | None | cod66 | Four Pole 125 A 25 kA (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6, Clause 5.15.2) | Each | 8598.0 | 8598.0 | 2.0 | False | None | None | False | None | False | 17196.0 | 0 | | 3277105 | 113719 | None | cod67 | 4 Way (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6, Clause 5.17.1) | Each | 10329.0 | 10329.0 | 2.0 | False | None | None | False | None | False | 20658.0 | 0 | | 3277106 | 113719 | None | cod68 | 8 Way (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6, Clause 5.17.2) | Each | 12605.0 | 12605.0 | 2.0 | False | None | None | False | None | False | 25210.0 | 0 | | 3277107 | 113719 | None | cod69 | 12 Way (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6, Clause 5.17.3) | Each | 15529.0 | 15529.0 | 5.0 | False | None | None | False | None | False | 77645.0 | 0 | | 3277108 | 113719 | None | cod70 | 6-32 A SP (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6, Clause 5.18.1) | Each | 415.0 | 415.0 | 54.0 | False | None | None | False | None | False | 22410.0 | 0 | | 3277109 | 113719 | None | cod71 | 40 A SP (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6, Clause 5.18.2) | Each | 793.0 | 793.0 | 10.0 | False | None | None | False | None | False | 7930.0 | 0 | | 3277110 | 113719 | None | cod72 | 40 A DP (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6, Clause 5.18.5) | Each | 1060.0 | 1060.0 | 5.0 | False | None | None | False | None | False | 5300.0 | 0 | | 3277111 | 113719 | None | cod73 | 63 A 4 pole (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6, Clause 5.20.10) | Each | 5545.0 | 5545.0 | 1.0 | False | None | None | False | None | False | 5545.0 | 0 | | 3277112 | 113719 | None | cod74 | 63 A 4 pole | Each | 3058.0 | 3058.0 | 1.0 | False | None | None | False | None | False | 3058.0 | 0 | | 3277113 | 113719 | None | cod75 | 250 A 4 x 30 x 10 mm Aluminium Strips (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6, Clause 5.40.2) | Mtr | 3435.0 | 3435.0 | 3.0 | False | None | None | False | None | False | 10305.0 | 0 | | 3277114 | 113719 | None | cod76 | 12 Sweep (300 mm) (Common SR for KPTCL, ESCOMs & PWD Electrical 2023- 2024 Volume 6, Clause 6.2.1) | Each | 2969.0 | 2969.0 | 20.0 | False | None | None | False | None | False | 59380.0 | 0 | | 3277115 | 113719 | None | cod77 | 15 Sweep (450 mm) (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6, Clause 6.2.2) | Each | 4446.0 | 4446.0 | 32.0 | False | None | None | False | None | False | 142272.0 | 0 | | 3277116 | 113719 | None | cod78 | 48 Sweep 5 Star (1200 mm) (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6, Clause 6.4.1) | Each | 2677.0 | 2677.0 | 50.0 | False | None | None | False | None | False | 133850.0 | 0 | | 3277117 | 113719 | None | cod79 | 56 Sweep 5 Star (1400 mm) (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6, Clause 6.4.2) | Each | 3754.0 | 3754.0 | 70.0 | False | None | None | False | None | False | 262780.0 | 0 | | 3277118 | 113719 | None | cod80 | 400 mm Sweep (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6, Clause 6.5.2) | Each | 3212.0 | 3212.0 | 42.0 | False | None | None | False | None | False | 134904.0 | 0 | | 3277119 | 113719 | None | cod81 | Supplying and drawing UTP-CAT 6E LAN cable. (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6, Clause 8.1) | Mtr | 38.0 | 38.0 | 2800.0 | False | None | None | False | None | False | 106400.0 | 0 | | 3277120 | 113719 | None | cod82 | 12U with 450mm depth (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6, Clause 8.4.4) | Each | 8835.0 | 8835.0 | 2.0 | False | None | None | False | None | False | 17670.0 | 0 | | 3277121 | 113719 | None | cod83 | LED light fitting 1 x 4' - 36/40 W (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6, Clause 11.3.3) | Each | 1269.0 | 1269.0 | 200.0 | False | None | None | False | None | False | 253800.0 | 0 | | 3277122 | 113719 | None | cod84 | LED Post Top Lantern with 25/30 W (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6, Clause 11.7.2) | Each | 7722.0 | 7722.0 | 24.0 | False | None | None | False | None | False | 185328.0 | 0 |
| | 1718185432000 | 0 | None | None | Buildings | MAIN BUILDING PLUMBING AND SANITARY | 3943644.79 | | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
|---|
| 3277123 | 113720 | None | code01 | 20 mm nominal dia pipes (PWD SR for Buildings 2023 - 2024 Vol. - 2, Sl.No. 13.32.2, page 122) | Mtr | 379.0 | 379.0 | 300.0 | False | None | None | False | None | False | 113700.0 | 0 | | 3277124 | 113720 | None | code02 | 25 mm nominal dia pipes (PWD SR for Buildings 2023 - 2024 Vol. - 2, Sl.No. 13.32.3, page 122) | Mtr | 477.0 | 477.0 | 200.0 | False | None | None | False | None | False | 95400.0 | 0 | | 3277125 | 113720 | None | code03 | 32 mm nominal dia pipes (PWD SR for Buildings 2023 - 2024 Vol. - 2, Sl.No. 13.32.4, page 122) | Mtr | 557.0 | 557.0 | 200.0 | False | None | None | False | None | False | 111400.0 | 0 | | 3277126 | 113720 | None | code04 | 20 mm nominal dia pipes (PWD SR for Buildings 2023 - 2024 Vol. - 2, Sl.No. 13.33.2, page 122) | Mtr | 217.0 | 217.0 | 200.0 | False | None | None | False | None | False | 43400.0 | 0 | | 3277127 | 113720 | None | code05 | 25 mm nominal dia pipes (PWD SR for Buildings 2023 - 2024 Vol. - 2, Sl.No. 13.33.3, page 122) | Mtr | 296.0 | 296.0 | 400.0 | False | None | None | False | None | False | 118400.0 | 0 | | 3277128 | 113720 | None | code06 | 50 mm nominal dia pipes (PWD SR for Buildings 2023 - 2024 Vol. - 2, Sl.No. 13.33.6, page 123) | Mtr | 721.0 | 721.0 | 600.0 | False | None | None | False | None | False | 432600.0 | 0 | | 3277129 | 113720 | None | code07 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. (PWD SR for Buildings 2023 - 2024 Vol. - 2, Sl.No. 13.34, page 123) | l | 9.0 | 9.0 | 10000.0 | False | None | None | False | None | False | 90000.0 | 0 | | 3277130 | 113720 | None | code08 | Making chases up to 7.5x7.5 cm in walls including making good and finishing with matching surface after housing G.I. pipe etc. (PWD SR for Buildings 2023 - 2024 Vol. - 2, Sl.No. 13.35, page 123) | Mtr | 133.0 | 133.0 | 200.0 | False | None | None | False | None | False | 26600.0 | 0 | | 3277131 | 113720 | None | code09 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 100 mm diameter (PWD SR for Buildings 2023 - 2024 Vol. - 2, Sl.No. 13.48, page 125) | Mtr | 291.0 | 291.0 | 80.0 | False | None | None | False | None | False | 23280.0 | 0 | | 3277132 | 113720 | None | code10 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes of 150mm dia conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. (PWD SR for Buildings 2023 - 2024 Vol. - 2, Sl.No. 13.49, page 125) | Mtr | 568.0 | 568.0 | 150.0 | False | None | None | False | None | False | 85200.0 | 0 | | 3277133 | 113720 | None | code11 | Providing and fixing Bib cock with wall flange made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete
- Premium Class (PWD SR for Buildings 2023 - 2024 Vol. - 2, Sl.No. 14.55 b, page 139) | Nos. | 2426.0 | 2426.0 | 56.0 | False | None | None | False | None | False | 135856.0 | 0 | | 3277134 | 113720 | None | code12 | Providing and fixing Overhead rain showers of minimum dimension 225x225mm & wall flange made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete - Premium Class (PWD SR for Buildings 2023 - 2024 Vol. - 2, Sl.No. 14.81, page 143) | Nos. | 5945.0 | 5945.0 | 6.0 | False | None | None | False | None | False | 35670.0 | 0 | | 3277135 | 113720 | None | code13 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 (PWD SR for Buildings 2023 - 2024 Vol. - 2, Sl.No. 14.22B, page 135) | Nos. | 620.0 | 620.0 | 120.0 | False | None | None | False | None | False | 74400.0 | 0 | | 3277136 | 113720 | None | code14 | Providing and fixing CP Brass 15 mm nominal dia Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. (PWD SR for Buildings 2023 - 2024 Vol. - 2, Sl.No. 13.16, page 119) | Nos. | 6436.64 | 6436.64 | 6.0 | False | None | None | False | None | False | 38619.84 | 0 | | 3277137 | 113720 | None | code15 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete (PWD SR for Buildings 2023 - 2024 Vol. - 2, Sl.No. 14.31, page 136) | Nos. | 1220.0 | 1220.0 | 32.0 | False | None | None | False | None | False | 39040.0 | 0 | | 3277138 | 113720 | None | code16 | Providing and fixing toilet paper holder (PWD SR for Buildings 2023 - 2024 Vol. - 2, Sl.No. 14.34.1, page 136) | Nos. | 608.0 | 608.0 | 32.0 | False | None | None | False | None | False | 19456.0 | 0 | | 3277139 | 113720 | None | code17 | Providing and fixing Towel rail 600mm length made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete - premium Class. (PWD SR for Buildings 2023 - 2024 Vol. - 2, Sl.No. 14.90.b, page 144) | Nos. | 3864.0 | 3864.0 | 32.0 | False | None | None | False | None | False | 123648.0 | 0 | | 3277140 | 113720 | None | code18 | Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: Inside dimensions 455x610 mm and 45 cm deep for single pipe line : With common burnt clay (non modular) bricks of class designation 3 (PWD SR for Buildings 2023 - 2024 Vol. - 2, Sl.No. 13.53, page 126) | Each | 5642.0 | 5642.0 | 12.0 | False | None | None | False | None | False | 67704.0 | 0 | | 3277141 | 113720 | None | code19 | Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 600X850 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete (PWD SR for Buildings 2023 - 2024 Vol. - 2, Sl.No. 13.55, page 127) | Each | 7401.0 | 7401.0 | 4.0 | False | None | None | False | None | False | 29604.0 | 0 | | 3277142 | 113720 | None | code20 | Making soak pit 2.5 m diameter 3.0 m deep with 45 x 45 cm dry brick honey comb shaft with bricks and PVC S.W.R drain pipe 100 mm diameter, 1.8 m long complete as per standard design.With common burnt clay (non modular) bricks of class designation 3.5 (PWD SR for Buildings 2023 - 2024 Vol. - 2, Sl.No. 13.56, page 127) | Each | 23024.0 | 23024.0 | 2.0 | False | None | None | False | None | False | 46048.0 | 0 | | 3277143 | 113720 | None | code21 | Providing and fixing PVC (S.W.R) Multi Floor Trap 10.0 cm x 7.5 cm x 5.0 cm x 4.0 cm with all fitting arrangements & all necessary accessories complete (PWD SR for Buildings 2023 - 2024 Vol. - 2, Sl.No. 13.63, page 128) | Each | 244.0 | 244.0 | 28.0 | False | None | None | False | None | False | 6832.0 | 0 | | 3277144 | 113720 | None | code23 | 75mm nominal dia pipes (PWD SR for Buildings 2023 - 2024 Vol. - 2, Sl.No. 13.64.1, page 128) | Mtr | 289.0 | 289.0 | 260.0 | False | None | None | False | None | False | 75140.0 | 0 | | 3277145 | 113720 | None | code24 | 110mm nominal dia pipes (PWD SR for Buildings 2023 - 2024 Vol. - 2, Sl.No. 13.64.2, page 128) | Mtr | 385.0 | 385.0 | 270.0 | False | None | None | False | None | False | 103950.0 | 0 | | 3277146 | 113720 | None | code25 | 150mm nominal dia pipes (PWD SR for Buildings 2023 - 2024 Vol. - 2, Sl.No. 13.64.3, page 128) | Mtr | 765.0 | 765.0 | 375.0 | False | None | None | False | None | False | 286875.0 | 0 | | 3277147 | 113720 | None | code26 | Providing and fixing floor mounted, white vitreous china single piece, double traps syphonic water closet of approved brand/make, shape, size and pattern including integrated white vitreous china cistern of capacity 10 litres with dual flushing system, including all fittings and fixtures with seat cover, cistern fittings, nuts, bolts and gasket etc including making connection with the existing P/S trap, complete in all respect as per directions of Engineer-in-Charge (PWD SR for Buildings 2023 - 2024 Vol.-2, Sl.No. 14.47, page 138) | Each | 14212.0 | 14212.0 | 38.0 | False | None | None | False | None | False | 540056.0 | 0 | | 3277148 | 113720 | None | code27 | Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water (250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-charge (PWD SR for Buildings 2023 - 2024 Vol. - 2, Sl.No. 14.46, page 138) | Each | 6238.0 | 6238.0 | 12.0 | False | None | None | False | None | False | 74856.0 | 0 | | 3277149 | 113720 | None | code28 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required: White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm
C.P. brass pillar taps (PWD SR for Buildings 2023 - 2024 Vol. - 2, Sl.No. 14.7.1, page 132) | Each | 3082.0 | 3082.0 | 32.0 | False | None | None | False | None | False | 98624.0 | 0 | | 3277150 | 113720 | None | code29 | Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings. (PWD SR for Buildings 2023 - 2024 Vol. - 2, Sl.No. 14.8, page 133) | Each | 1423.0 | 1423.0 | 32.0 | False | None | None | False | None | False | 45536.0 | 0 | | 3277151 | 113720 | None | code30 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required (PWD SR for Buildings 2023 - 2024 Vol. - 2, Sl.No. 14.10.1.1, page 133) Kitchen sink with drain board 510x1040 mm bowl depth 250 mm | Each | 5618.0 | 5618.0 | 6.0 | False | None | None | False | None | False | 33708.0 | 0 | | 3277152 | 113720 | None | code31 | Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer in charge:. (PWD SR for Buildings 2023 - 2024 Vol. - 2, Sl.No. 14.22A, page 135) | Each | 810.0 | 810.0 | 16.0 | False | None | None | False | None | False | 12960.0 | 0 | | 3277153 | 113720 | None | code32 | Bottle trap 38 mm single piece moulded with height of 270 mm, effective length of tail pipe 260mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 263 g (PWD SR for Buildings 2023 - 2024 Vol. - 2, Sl.No. 14.37.2, page 137) | Each | 318.0 | 318.0 | 38.0 | False | None | None | False | None | False | 12084.0 | 0 | | 3277154 | 113720 | None | code33 | Excavation and refilling (Vol 1 Common SR for Engineering Departments - 23-24) (Page 5, Specification 1.4.1), (Page 7, Specification 1.9 ) | Cum | 534.0 | 534.0 | 175.0 | False | None | None | False | None | False | 93450.0 | 0 | | 3277155 | 113720 | None | code34 | PCC 1:4:8 - 150mm thick (Vol 1 Common SR for Engineering Departments - 23-24(Page 15, Specification 2.1.2) | Cum | 6532.0 | 6532.0 | 12.0 | False | None | None | False | None | False | 78384.0 | 0 | | 3277156 | 113720 | None | code35 | Reinforcement steel (Vol-1 Uni SR 2023-24 Building , Page 18, Specification 2.11a ) | Kgs | 100.19 | 100.19 | 2205.0 | False | None | None | False | None | False | 220918.95 | 0 | | 3277157 | 113720 | None | code36 | M25 grade concrete for bottom mat (Vol 1 Common SR for Engineering Departments - 23-24Page 15, Specification 2.2.2.1) | Cum | 7867.0 | 7867.0 | 15.0 | False | None | None | False | None | False | 118005.0 | 0 | | 3277158 | 113720 | None | code37 | M25 grade concrete for side, intermediate and baffle walls (Vol 1 Common SR for Engineering Departments - 23-24) (Page 17, Specification 2.5.2) | Cum | 11386.0 | 11386.0 | 15.0 | False | None | None | False | None | False | 170790.0 | 0 | | 3277159 | 113720 | None | code38 | M25 grade concrete for cover slab (Vol 1 Common SR for Engineering Departments - 23-24) (Page 17, Specification 2.5.2) | Cum | 11386.0 | 11386.0 | 10.0 | False | None | None | False | None | False | 113860.0 | 0 | | 3277160 | 113720 | None | code39 | 25mm thick Plastering in CM 1:4 for insides (Vol-2 Uni SR 2023-24 Building) (Page 42, Specification 8.6.2) | Sqm | 485.0 | 485.0 | 194.0 | False | None | None | False | None | False | 94090.0 | 0 | | 3277161 | 113720 | None | code40 | PVC Manhole covers | Each | 4500.0 | 4500.0 | 3.0 | False | None | None | False | None | False | 13500.0 | 0 |
| | 1718185432000 | 0 | None | None | Buildings | FRONT BUILDING ELECTRICAL | 1498814.0 | | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
|---|
| 3277162 | 113721 | None | code01 | 19/20 mm dia 2 mm thick (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6, Clause 1.2.1) | Mtr | 66.0 | 66.0 | 148.0 | False | None | None | False | None | False | 9768.0 | 0 | | 3277163 | 113721 | None | code02 | 25 mm dia 2 mm thick (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6, Clause 1.2.2) | Mtr | 78.0 | 78.0 | 120.0 | False | None | None | False | None | False | 9360.0 | 0 | | 3277164 | 113721 | None | code03 | 32 mm dia 2.5 mm thick (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6, Clause 1.2.3) | Mtr | 103.0 | 103.0 | 100.0 | False | None | None | False | None | False | 10300.0 | 0 | | 3277165 | 113721 | None | code04 | 40 mm dia 2.5 mm thick (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6, Clause 1.2.4) | Mtr | 147.0 | 147.0 | 80.0 | False | None | None | False | None | False | 11760.0 | 0 | | 3277166 | 113721 | None | code05 | 19/20 mm dia 2 mm thick (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6, Clause 1.3.1) | Mtr | 68.0 | 68.0 | 273.0 | False | None | None | False | None | False | 18564.0 | 0 | | 3277167 | 113721 | None | code06 | 25 mm dia 2 mm thick (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6, Clause 1.3.2) | Mtr | 79.0 | 79.0 | 247.0 | False | None | None | False | None | False | 19513.0 | 0 | | 3277168 | 113721 | None | code07 | 32 mm dia 2.5 mm thick (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6, Clause 1.3.3) | Mtr | 99.0 | 99.0 | 187.0 | False | None | None | False | None | False | 18513.0 | 0 | | 3277169 | 113721 | None | code08 | 40 mm dia 2.5 mm thick (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6, Clause 1.3.4) | Mtr | 139.0 | 139.0 | 40.0 | False | None | None | False | None | False | 5560.0 | 0 | | 3277170 | 113721 | None | code09 | 75 x 75 x 65 mm (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6, Clause 1.4.1) | Each | 106.0 | 106.0 | 22.0 | False | None | None | False | None | False | 2332.0 | 0 | | 3277171 | 113721 | None | code10 | 100 x 75 x 65 mm (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6, Clause 1.4.2) | Each | 118.0 | 118.0 | 14.0 | False | None | None | False | None | False | 1652.0 | 0 | | 3277172 | 113721 | None | code11 | 135 x 75 x 65 mm (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6, Clause 1.4.3) | Each | 139.0 | 139.0 | 12.0 | False | None | None | False | None | False | 1668.0 | 0 | | 3277173 | 113721 | None | code12 | 180 x 90 x 65 mm (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6, Clause 1.4.4) | Each | 161.0 | 161.0 | 22.0 | False | None | None | False | None | False | 3542.0 | 0 | | 3277174 | 113721 | None | code13 | 200 x 90 x 65 mm (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6, Clause 1.4.5) | Each | 179.0 | 179.0 | 8.0 | False | None | None | False | None | False | 1432.0 | 0 | | 3277175 | 113721 | None | code14 | 135 x 160 x 65 mm (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6, Clause 1.4.6) | Each | 215.0 | 215.0 | 6.0 | False | None | None | False | None | False | 1290.0 | 0 | | 3277176 | 113721 | None | code15 | 200 x 200 x 65 mm (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6, Clause 1.4.7) | Each | 348.0 | 348.0 | 4.0 | False | None | None | False | None | False | 1392.0 | 0 | | 3277177 | 113721 | None | code16 | 19/20 mm deep Junction box (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6, Clause 1.5.1) | Each | 49.0 | 49.0 | 41.0 | False | None | None | False | None | False | 2009.0 | 0 | | 3277178 | 113721 | None | code17 | 25 mm deep Junction box (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6, Clause 1.5.2) | Each | 56.0 | 56.0 | 38.0 | False | None | None | False | None | False | 2128.0 | 0 | | 3277179 | 113721 | None | code18 | 32 mm deep Junction box (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6, Clause 1.5.3) | Each | 61.0 | 61.0 | 10.0 | False | None | None | False | None | False | 610.0 | 0 | | 3277180 | 113721 | None | code19 | upto 50 mm conduit in brick wall (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6, Clause 1.7.1) | Mtr | 29.0 | 29.0 | 14.0 | False | None | None | False | None | False | 406.0 | 0 | | 3277181 | 113721 | None | code20 | upto 50 mm conduit CC floor (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6, Clause 1.7.2) | Mtr | 66.0 | 66.0 | 11.0 | False | None | None | False | None | False | 726.0 | 0 | | 3277182 | 113721 | None | code21 | Supplying And Fixing "S" Hook made out of 14 mm dia M.S. Rod. (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6, Clause 1.11) | Each | 52.0 | 52.0 | 14.0 | False | None | None | False | None | False | 728.0 | 0 | | 3277183 | 113721 | None | code22 | Supplying And Fixing M.S. Rafter Clamp Set made out of M.S. Flat & 14 mm M.S. rod (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6, Clause 1.12) | Each | 160.0 | 160.0 | 27.0 | False | None | None | False | None | False | 4320.0 | 0 | | 3277184 | 113721 | None | code23 | Supplying And Fixing Metal Fan Box with Round Hook (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6, Clause 1.13) | Each | 117.0 | 117.0 | 26.0 | False | None | None | False | None | False | 3042.0 | 0 | | 3277185 | 113721 | None | code24 | Short point upto 3m from tapping point to out let via switch box (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6, Clause 2.1.2) | Each | 285.0 | 285.0 | 59.0 | False | None | None | False | None | False | 16815.0 | 0 | | 3277186 | 113721 | None | code25 | Medium point above 3m upto 6m from tapping point to out let via switch box (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6, Clause 2.2.2) | Each | 394.0 | 394.0 | 91.0 | False | None | None | False | None | False | 35854.0 | 0 | | 3277187 | 113721 | None | code26 | Long point above 6m upto 10m from tapping point to out let via switch (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6, Clause 2.1.3) | Each | 570.0 | 570.0 | 38.0 | False | None | None | False | None | False | 21660.0 | 0 | | 3277188 | 113721 | None | code27 | Two outlet in a row, above 3m upto 6m from tapping point to out let via switches (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6, Clause 2.1.4) | Each | 708.0 | 708.0 | 6.0 | False | None | None | False | None | False | 4248.0 | 0 | | 3277189 | 113721 | None | code28 | Three outlet in a row, above 6m upto 10m from tapping point to out let via switches box (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6, Clause 2.1.5) | Each | 1035.0 | 1035.0 | 3.0 | False | None | None | False | None | False | 3105.0 | 0 | | 3277190 | 113721 | None | code29 | 1 mm2 (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6, Clause 2.3.1) | Mtr | 19.0 | 19.0 | 1100.0 | False | None | None | False | None | False | 20900.0 | 0 | | 3277191 | 113721 | None | code30 | 1.5 mm2 (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6, Clause 2.3.2) | Mtr | 26.0 | 26.0 | 1293.0 | False | None | None | False | None | False | 33618.0 | 0 | | 3277192 | 113721 | None | code31 | 2.5 mm2 (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6, Clause 2.3.3) | Mtr | 42.0 | 42.0 | 1512.0 | False | None | None | False | None | False | 63504.0 | 0 | | 3277193 | 113721 | None | code32 | 4 mm2 (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6, Clause 2.3.4) | Mtr | 63.0 | 63.0 | 866.0 | False | None | None | False | None | False | 54558.0 | 0 | | 3277194 | 113721 | None | code33 | 6 mm2 (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6, Clause 2.3.5) | Mtr | 92.0 | 92.0 | 422.0 | False | None | None | False | None | False | 38824.0 | 0 | | 3277195 | 113721 | None | code34 | 10 mm2 (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6, Clause 2.3.6) | Mtr | 167.0 | 167.0 | 125.0 | False | None | None | False | None | False | 20875.0 | 0 | | 3277196 | 113721 | None | code35 | 4C x 1.5 mm2 (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6, Clause 2.5.3) | Mtr | 94.0 | 94.0 | 320.0 | False | None | None | False | None | False | 30080.0 | 0 | | 3277197 | 113721 | None | code36 | 3C x 2.5 mm2 (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6, Clause 2.6.1) | Mtr | 117.0 | 117.0 | 80.0 | False | None | None | False | None | False | 9360.0 | 0 | | 3277198 | 113721 | None | code37 | 1-2 Way (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6, Clause 3.4.1) | Each | 138.0 | 138.0 | 28.0 | False | None | None | False | None | False | 3864.0 | 0 | | 3277199 | 113721 | None | code38 | 4-5 Way (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6, Clause 3.4.3) | Each | 177.0 | 177.0 | 22.0 | False | None | None | False | None | False | 3894.0 | 0 | | 3277200 | 113721 | None | code39 | 6 Way (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6, Clause 3.4.4) | Each | 220.0 | 220.0 | 14.0 | False | None | None | False | None | False | 3080.0 | 0 | | 3277201 | 113721 | None | code40 | 8 Way (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6, Clause 3.4.5) | Each | 261.0 | 261.0 | 12.0 | False | None | None | False | None | False | 3132.0 | 0 | | 3277202 | 113721 | None | code41 | 10-12 Way (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6, Clause 3.4.6) | Each | 319.0 | 319.0 | 22.0 | False | None | None | False | None | False | 7018.0 | 0 | | 3277203 | 113721 | None | code42 | 16 Way (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6, Clause 3.4.7) | Each | 363.0 | 363.0 | 8.0 | False | None | None | False | None | False | 2904.0 | 0 | | 3277204 | 113721 | None | code43 | 1 to 2 Module (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6, Clause 3.5.1) | Each | 137.0 | 137.0 | 28.0 | False | None | None | False | None | False | 3836.0 | 0 | | 3277205 | 113721 | None | code44 | 3 Module (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6, Clause 3.5.1) | Each | 161.0 | 161.0 | 22.0 | False | None | None | False | None | False | 3542.0 | 0 | | 3277206 | 113721 | None | code45 | 4 Module (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6, Clause 3.5.2) | Each | 175.0 | 175.0 | 14.0 | False | None | None | False | None | False | 2450.0 | 0 | | 3277207 | 113721 | None | code46 | 6 Module (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6, Clause 3.5.3) | Each | 234.0 | 234.0 | 12.0 | False | None | None | False | None | False | 2808.0 | 0 | | 3277208 | 113721 | None | code47 | 8 Module (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6, Clause 3.5.4) | Each | 284.0 | 284.0 | 22.0 | False | None | None | False | None | False | 6248.0 | 0 | | 3277209 | 113721 | None | code48 | 10-12 Module (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6, Clause 3.5.5) | Each | 344.0 | 344.0 | 8.0 | False | None | None | False | None | False | 2752.0 | 0 | | 3277210 | 113721 | None | code49 | 16 Module (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6, Clause 3.5.6) | Each | 397.0 | 397.0 | 6.0 | False | None | None | False | None | False | 2382.0 | 0 | | 3277211 | 113721 | None | code50 | 6A One Way Switch (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6, Clause 3.6.1) | Each | 102.0 | 102.0 | 174.0 | False | None | None | False | None | False | 17748.0 | 0 | | 3277212 | 113721 | None | code51 | 6A Two Way Switch (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6, Clause 3.6.2) | Each | 166.0 | 166.0 | 11.0 | False | None | None | False | None | False | 1826.0 | 0 | | 3277213 | 113721 | None | code52 | 6A Three Way socket (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6, Clause 3.6.3) | Each | 171.0 | 171.0 | 53.0 | False | None | None | False | None | False | 9063.0 | 0 | | 3277214 | 113721 | None | code53 | Stepped Fan Regulator Two Module (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6, Clause 3.6.4) | Each | 357.0 | 357.0 | 32.0 | False | None | None | False | None | False | 11424.0 | 0 | | 3277215 | 113721 | None | code54 | 16A One Way Switch (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6, Clause 3.6.7) | Each | 180.0 | 180.0 | 22.0 | False | None | None | False | None | False | 3960.0 | 0 | | 3277216 | 113721 | None | code55 | 6A Bell Push (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6, Clause 3.6.8) | Each | 177.0 | 177.0 | 3.0 | False | None | None | False | None | False | 531.0 | 0 | | 3277217 | 113721 | None | code56 | 32A DP Switch (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6, Clause 3.6.9) | Each | 326.0 | 326.0 | 11.0 | False | None | None | False | None | False | 3586.0 | 0 | | 3277218 | 113721 | None | code57 | 6/16A Universal Socket (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6, Clause 3.6.10) | Each | 236.0 | 236.0 | 22.0 | False | None | None | False | None | False | 5192.0 | 0 | | 3277219 | 113721 | None | code58 | TV/Telephone Socket (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6, Clause 3.6.11) | Each | 156.0 | 156.0 | 16.0 | False | None | None | False | None | False | 2496.0 | 0 | | 3277220 | 113721 | None | code59 | RJ45/I.O Outlet Cat-6 (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6, Clause 3.6.12) | Each | 337.0 | 337.0 | 11.0 | False | None | None | False | None | False | 3707.0 | 0 | | 3277221 | 113721 | None | code60 | Supply and erection of 14 Feet Height Street Light Pole 14 Feet Height Street Light Pole on suitable cement concrete foundation with 2.5 Feet height dia 95 mm cast iron decorative round pedestal as per design weighing not less than 37Kgs, the pedestal shall be fitted with Class 'C' G.I.Pipe 7 Feet height 75 mm outer dia and 7 feet height top piece outer dia of 65 mm fixed by measure of threading/welding/coupling complete. (excluding foundation). (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6, Clause 4.3) | Each | 20600.0 | 20600.0 | 18.0 | False | None | None | False | None | False | 370800.0 | 0 | | 3277222 | 113721 | None | code61 | upto 12.5 HP (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6, Clause 5.2.1) | Each | 7455.0 | 7455.0 | 1.0 | False | None | None | False | None | False | 7455.0 | 0 | | 3277223 | 113721 | None | code62 | 125 A (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6, Clause 5.11.3) | Each | 10326.0 | 10326.0 | 1.0 | False | None | None | False | None | False | 10326.0 | 0 | | 3277224 | 113721 | None | code63 | Three pole100 A 25 kA (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6, Clause 5.15.1) | Each | 6068.0 | 6068.0 | 2.0 | False | None | None | False | None | False | 12136.0 | 0 | | 3277225 | 113721 | None | code64 | Four Pole 125 A 25 kA (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6, Clause 5.15.2) | Each | 8598.0 | 8598.0 | 1.0 | False | None | None | False | None | False | 8598.0 | 0 | | 3277226 | 113721 | None | code65 | 4 Way (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6, Clause 5.17.1) | Each | 10329.0 | 10329.0 | 1.0 | False | None | None | False | None | False | 10329.0 | 0 | | 3277227 | 113721 | None | code66 | 8 Way (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6, Clause 5.17.2) | Each | 12605.0 | 12605.0 | 1.0 | False | None | None | False | None | False | 12605.0 | 0 | | 3277228 | 113721 | None | code67 | 12 Way (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6, Clause 5.17.3) | Each | 15529.0 | 15529.0 | 2.0 | False | None | None | False | None | False | 31058.0 | 0 | | 3277229 | 113721 | None | code68 | 6-32 A SP (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6, Clause 5.18.1) | Each | 415.0 | 415.0 | 1.0 | False | None | None | False | None | False | 415.0 | 0 | | 3277230 | 113721 | None | code69 | 40 A SP (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6, Clause 5.18.2) | Each | 793.0 | 793.0 | 1.0 | False | None | None | False | None | False | 793.0 | 0 | | 3277231 | 113721 | None | code70 | 40 A DP (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6, Clause 5.18.5) | Each | 1060.0 | 1060.0 | 2.0 | False | None | None | False | None | False | 2120.0 | 0 | | 3277232 | 113721 | None | code71 | 63 A 4 pole (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6, Clause 5.20.10) | Each | 5545.0 | 5545.0 | 1.0 | False | None | None | False | None | False | 5545.0 | 0 | | 3277233 | 113721 | None | code72 | 63 A 4 pole (SR 2022-23, Clause 5.20.4) | Each | 3058.0 | 3058.0 | 2.0 | False | None | None | False | None | False | 6116.0 | 0 | | 3277234 | 113721 | None | code73 | 250 A 4 x 30 x 10 mm Aluminium Strips (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6, Clause 5.40.2) | Mtr | 3435.0 | 3435.0 | 3.0 | False | None | None | False | None | False | 10305.0 | 0 | | 3277235 | 113721 | None | code74 | 12 Sweep (300 mm) (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6, Clause 6.2.1) | Each | 2969.0 | 2969.0 | 12.0 | False | None | None | False | None | False | 35628.0 | 0 | | 3277236 | 113721 | None | code75 | 15 Sweep (450 mm) (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6, Clause 6.2.2) | Each | 4446.0 | 4446.0 | 6.0 | False | None | None | False | None | False | 26676.0 | 0 | | 3277237 | 113721 | None | code76 | 48 Sweep 5 Star (1200 mm) (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6, Clause 6.4.1) | Each | 2677.0 | 2677.0 | 26.0 | False | None | None | False | None | False | 69602.0 | 0 | | 3277238 | 113721 | None | code77 | Supplying of feet -PVC Batten with integrated LED tube .... W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V@ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6, Clause 11.3) | Each | 1269.0 | 1269.0 | 80.0 | False | None | None | False | None | False | 101520.0 | 0 | | 3277239 | 113721 | None | code78 | LED Post Top Lantern with 25/30 W (Common SR for KPTCL, ESCOMs & PWD Electrical 2023 - 2024 Volume 6, Clause 11.7.2) | Each | 7722.0 | 7722.0 | 24.0 | False | None | None | False | None | False | 185328.0 | 0 |
| | 1718185432000 | 0 | None | None | Buildings | FRONT BUILDING PLUMBING AND SANITARY | 2082863.15 | | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
|---|
| 3277240 | 113722 | None | code01 | 20 mm nominal dia pipes (PWD SR for Buildings 2023 - 2024 Vol. - 2, Sl.No. 13.32.2, page 122) | Mtr | 379.0 | 379.0 | 30.0 | False | None | None | False | None | False | 11370.0 | 0 | | 3277241 | 113722 | None | code02 | 25 mm nominal dia pipes (PWD SR for Buildings 2023 - 2024 Vol. - 2, Sl.No. 13.32.3, page 122) | Mtr | 477.0 | 477.0 | 50.0 | False | None | None | False | None | False | 23850.0 | 0 | | 3277242 | 113722 | None | code03 | 32 mm nominal dia pipes (PWD SR for Buildings 2023 - 2024 Vol. - 2, Sl.No. 13.32.4, page 122) | Mtr | 557.0 | 557.0 | 20.0 | False | None | None | False | None | False | 11140.0 | 0 | | 3277243 | 113722 | None | code04 | 20 mm nominal dia pipes (PWD SR for Buildings 2023 - 2024 Vol. - 2, Sl.No. 13.33.2, page 122) | Mtr | 217.0 | 217.0 | 100.0 | False | None | None | False | None | False | 21700.0 | 0 | | 3277244 | 113722 | None | code05 | 25 mm nominal dia pipes (PWD SR for Buildings 2023 - 2024 Vol. - 2, Sl.No. 13.33.3, page 122) | Mtr | 296.0 | 296.0 | 120.0 | False | None | None | False | None | False | 35520.0 | 0 | | 3277245 | 113722 | None | code06 | 50 mm nominal dia pipes (PWD SR for Buildings 2023 - 2024 Vol. - 2, Sl.No. 13.33.6, page 123) | Mtr | 721.0 | 721.0 | 180.0 | False | None | None | False | None | False | 129780.0 | 0 | | 3277246 | 113722 | None | code07 | Making chases up to 7.5x7.5 cm in walls including making good and finishing with matching surface after housing G.I. pipe etc. (PWD SR for Buildings 2023 - 2024 Vol. - 2, Sl.No. 13.35, page 123) | Mtr | 133.0 | 133.0 | 80.0 | False | None | None | False | None | False | 10640.0 | 0 | | 3277247 | 113722 | None | code08 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 100 mm diameter (PWD SR for Buildings 2023 - 2024 Vol. - 2, Sl.No. 13.48, page 125) | Mtr | 291.0 | 291.0 | 80.0 | False | None | None | False | None | False | 23280.0 | 0 | | 3277248 | 113722 | None | code09 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes of 150mm dia conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. (PWD SR for Buildings 2023 - 2024 Vol. - 2, Sl.No. 13.49, page 125) | Mtr | 568.0 | 568.0 | 100.0 | False | None | None | False | None | False | 56800.0 | 0 | | 3277249 | 113722 | None | code10 | Providing and fixing Bib cock with wall flange made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete
- Premium Class (PWD SR for Buildings 2023 - 2024 Vol. - 2, Sl.No. 14.55 b, page 139) | Nos. | 2426.0 | 2426.0 | 19.0 | False | None | None | False | None | False | 46094.0 | 0 | | 3277250 | 113722 | None | code11 | Providing and fixing Overhead rain showers of minimum dimension 225x225mm & wall flange made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete - Premium Class (PWD SR for Buildings 2023 - 2024 Vol. - 2, Sl.No. 14.81, page 143) | Nos. | 5945.0 | 5945.0 | 5.0 | False | None | None | False | None | False | 29725.0 | 0 | | 3277251 | 113722 | None | code12 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 (PWD SR for Buildings 2023 - 2024 Vol. - 2, Sl.No. 14.22B, page 135) | Nos. | 620.0 | 620.0 | 18.0 | False | None | None | False | None | False | 11160.0 | 0 | | 3277252 | 113722 | None | code13 | Providing and fixing CP Brass 15 mm nominal dia Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. (PWD SR for Buildings 2023 - 2024 Vol. - 2, Sl.No. 13.16, page 119) | Nos. | 6436.64 | 6436.64 | 5.0 | False | None | None | False | None | False | 32183.2 | 0 | | 3277253 | 113722 | None | code14 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete (PWD SR for Buildings 2023 - 2024 Vol. - 2, Sl.No. 14.31, page 136) | Nos. | 1220.0 | 1220.0 | 20.0 | False | None | None | False | None | False | 24400.0 | 0 | | 3277254 | 113722 | None | code15 | Providing and fixing toilet paper holder (PWD SR for Buildings 2023 - 2024 Vol. - 2, Sl.No. 14.34.1, page 136) | Nos. | 608.0 | 608.0 | 19.0 | False | None | None | False | None | False | 11552.0 | 0 | | 3277255 | 113722 | None | code16 | Providing and fixing Towel rail 600mm length made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete - premium Class. (PWD SR for Buildings 2023 - 2024 Vol. - 2, Sl.No. 14.90.b, page 144) | Nos. | 3864.0 | 3864.0 | 5.0 | False | None | None | False | None | False | 19320.0 | 0 | | 3277256 | 113722 | None | code17 | Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: Inside dimensions 455x610 mm and 45 cm deep for single pipe line : With common burnt clay (non modular) bricks of class designation 3 (PWD SR for Buildings 2023 - 2024 Vol. - 2, Sl.No. 13.53, page 126) | Each | 5642.0 | 5642.0 | 6.0 | False | None | None | False | None | False | 33852.0 | 0 | | 3277257 | 113722 | None | code18 | Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 600X850 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete (PWD SR for Buildings 2023 - 2024 Vol. - 2, Sl.No. 13.55, page 127) | Each | 7401.0 | 7401.0 | 2.0 | False | None | None | False | None | False | 14802.0 | 0 | | 3277258 | 113722 | None | code19 | Making soak pit 2.5 m diameter 3.0 m deep with 45 x 45 cm dry brick honey comb shaft with bricks and PVC S.W.R drain pipe 100 mm diameter, 1.8 m long complete as per standard design.With common burnt clay (non modular) bricks of class designation 3.5 (PWD SR for Buildings 2023 - 2024 Vol. - 2, Sl.No. 13.56, page 127) | Each | 23024.0 | 23024.0 | 1.0 | False | None | None | False | None | False | 23024.0 | 0 | | 3277259 | 113722 | None | code20 | Providing and fixing PVC (S.W.R) Multi Floor Trap 10.0 cm x 7.5 cm x 5.0 cm x 4.0 cm with all fitting arrangements & all necessary accessories complete (PWD SR for Buildings 2023 - 2024 Vol. - 2, Sl.No. 13.63, page 128) | Each | 244.0 | 244.0 | 18.0 | False | None | None | False | None | False | 4392.0 | 0 | | 3277260 | 113722 | None | code21 | 75mm nominal dia pipes (PWD SR for Buildings 2023 - 2024 Vol. - 2, Sl.No. 13.64.1, page 128) | Mtr | 289.0 | 289.0 | 80.0 | False | None | None | False | None | False | 23120.0 | 0 | | 3277261 | 113722 | None | code22 | 110mm nominal dia pipes (PWD SR for Buildings 2023 - 2024 Vol. - 2, Sl.No. 13.64.2, page 128) | Mtr | 385.0 | 385.0 | 100.0 | False | None | None | False | None | False | 38500.0 | 0 | | 3277262 | 113722 | None | code23 | 150mm nominal dia pipes (PWD SR for Buildings 2023 - 2024 Vol. - 2, Sl.No. 13.64.3, page 128) | Mtr | 765.0 | 765.0 | 95.0 | False | None | None | False | None | False | 72675.0 | 0 | | 3277263 | 113722 | None | code24 | Providing and fixing floor mounted, white vitreous china single piece, double traps syphonic water closet of approved brand/make, shape, size and pattern including integrated white vitreous china cistern of capacity 10 litres with dual flushing system, including all fittings and fixtures with seat cover, cistern fittings, nuts, bolts and gasket etc including making connection with the existing P/S trap, complete in all respect as per directions of Engineer-in-Charge (PWD SR for Buildings 2023 - 2024 Vol. - 2, Sl.No. 14.47, page 138) | Each | 14212.0 | 14212.0 | 19.0 | False | None | None | False | None | False | 270028.0 | 0 | | 3277264 | 113722 | None | code25 | Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water (250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-charge (PWD SR for Buildings 2023 - 2024 Vol. - 2, Sl.No. 14.46, page 138) | Each | 6238.0 | 6238.0 | 11.0 | False | None | None | False | None | False | 68618.0 | 0 | | 3277265 | 113722 | None | code26 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required: White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm
C.P. brass pillar taps (PWD SR for Buildings 2023 - 2024 Vol. - 2, Sl.No. 14.7.1, page 132) | Each | 3082.0 | 3082.0 | 19.0 | False | None | None | False | None | False | 58558.0 | 0 | | 3277266 | 113722 | None | code27 | Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings. (PWD SR for Buildings 2023 - 2024 Vol. - 2, Sl.No. 14.8, page 133) | Each | 1423.0 | 1423.0 | 32.0 | False | None | None | False | None | False | 45536.0 | 0 | | 3277267 | 113722 | None | code28 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required (PWD SR for Buildings 2023 - 2024 Vol. - 2, Sl.No. 14.10.1.1, page 133) Kitchen sink with drain board 510x1040 mm bowl depth 250 mm | Each | 5618.0 | 5618.0 | 2.0 | False | None | None | False | None | False | 11236.0 | 0 | | 3277268 | 113722 | None | code29 | Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer in charge:. (PWD SR for Buildings 2023 - 2024 Vol. - 2, Sl.No. 14.22A, page 135) | Each | 810.0 | 810.0 | 21.0 | False | None | None | False | None | False | 17010.0 | 0 | | 3277269 | 113722 | None | code30 | Excavation and refilling (Vol 1 Common SR for Engineering Departments - 23-24) (Page 5, Specification 1.4.1), (Page 7, Specification 1.9 ) | Cum | 534.0 | 534.0 | 175.0 | False | None | None | False | None | False | 93450.0 | 0 | | 3277270 | 113722 | None | code31 | PCC 1:4:8 - 150mm thick (Vol 1 Common SR for Engineering Departments - 23-24(Page 15, Specification 2.1.2) | Cum | 6532.0 | 6532.0 | 12.0 | False | None | None | False | None | False | 78384.0 | 0 | | 3277271 | 113722 | None | code32 | Reinforcement steel (Vol-1 Uni SR 2023-24 Building , Page 18, Specification 2.11a ) | Kgs | 100.19 | 100.19 | 2205.0 | False | None | None | False | None | False | 220918.95 | 0 | | 3277272 | 113722 | None | code33 | M25 grade concrete for bottom mat (Vol 1 Common SR for Engineering Departments - 23-24Page 15, Specification 2.2.2.1) | Cum | 7867.0 | 7867.0 | 15.0 | False | None | None | False | None | False | 118005.0 | 0 | | 3277273 | 113722 | None | code34 | M25 grade concrete for side, intermediate and baffle walls (Vol 1 Common SR for Engineering Departments - 23-24) (Page 17, Specification 2.5.2) | Cum | 11386.0 | 11386.0 | 15.0 | False | None | None | False | None | False | 170790.0 | 0 | | 3277274 | 113722 | None | code35 | M25 grade concrete for cover slab (Vol 1 Common SR for Engineering Departments - 23-24) (Page 17, Specification 2.5.2) | Cum | 11386.0 | 11386.0 | 10.0 | False | None | None | False | None | False | 113860.0 | 0 | | 3277275 | 113722 | None | code36 | 25mm thick Plastering in CM 1:4 for insides (Vol-2 Uni SR 2023-24 Building) (Page 42, Specification 8.6.2) | Sqm | 485.0 | 485.0 | 194.0 | False | None | None | False | None | False | 94090.0 | 0 | | 3277276 | 113722 | None | code37 | PVC Manhole covers | Each | 4500.0 | 4500.0 | 3.0 | False | None | None | False | None | False | 13500.0 | 0 |
| | 1718185432000 | 0 | None | None | Buildings | FRONT BUILDING ABSTRACT | 20366860.91 | | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
|---|
| 3277277 | 113723 | None | code01 | Vol 1 Common SR for Engineering Departments - 23-24) Earth work in surface excavation for stripping, seating of bund, Road way, by manual means for lowering & leveling the ground for all works other than foundation & depth in all kinds of soil not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work.. (Page 5, Specification 1.1) | Sqm | 102.0 | 102.0 | 1575.23 | False | None | None | False | None | False | 160673.46 | 0 | | 3277278 | 113723 | None | code02 | Vol 1 Common SR for Engineering Departments - 23-24) Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m (Page 5, Specification 1.4.1)Note: Cost of De-watering upto 5 % may be added, where required assessment for dewatering shall be made as per site condition | Cum | 271.0 | 271.0 | 249.41 | False | None | None | False | None | False | 67590.11 | 0 | | 3277279 | 113723 | None | code03 | Vol 1 Common SR for Engineering Departments - 23-24) Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. (Page 7, Specification 1.9) | Cum | 263.0 | 263.0 | 249.41 | False | None | None | False | None | False | 65594.83 | 0 | | 3277280 | 113723 | None | code04 | Vol-2 Uni SR 2023-24 Building) Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications. (Page 5, Specification 4.1) | Sqm | 132.0 | 132.0 | 479.28 | False | None | None | False | None | False | 63264.96 | 0 | | 3277281 | 113723 | None | code05 | Vol 1 Common SR for Engineering Departments - 23-24) Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes ma chine mixed, laid in layers not exceeding 150 mm thickness, well com pacted using plate vibrators, including all lead & lifts, cost of all materi als of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates (Page 15, Specification 2.1.2) | Cum | 6532.0 | 6532.0 | 101.59 | False | None | None | False | None | False | 663585.88 | 0 | | 3277282 | 113723 | None | code06 | Ground Floor windows / ventilator sills | Cum | 7272.0 | 7272.0 | 0.38 | False | None | None | False | None | False | 2763.36 | 0 | | 3277283 | 113723 | None | code07 | First Floor windows / ventilator sills | Cum | 7345.0 | 7345.0 | 0.82 | False | None | None | False | None | False | 6022.9 | 0 | | 3277284 | 113723 | None | code08 | Vol 1 Common SR for Engineering Departments - 23-24) Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates and including formwork (Page 15, Specification 2.2.2.1 Appendix 1, page 29,30) | Cum | 7867.0 | 7867.0 | 54.87 | False | None | None | False | None | False | 431662.29 | 0 | | 3277285 | 113723 | None | code09 | Ground Floor | Cum | 12904.0 | 12904.0 | 17.06 | False | None | None | False | None | False | 220142.24 | 0 | | 3277286 | 113723 | None | code10 | First Floor | Cum | 13032.0 | 13032.0 | 13.77 | False | None | None | False | None | False | 179450.64 | 0 | | 3277287 | 113723 | None | code11 | Ground Floor | Cum | 13032.0 | 13032.0 | 11.87 | False | None | None | False | None | False | 154689.84 | 0 | | 3277288 | 113723 | None | code12 | First Floor | Cum | 13161.0 | 13161.0 | 14.21 | False | None | None | False | None | False | 187017.81 | 0 | | 3277289 | 113723 | None | code13 | Ground Floor | Sqm | 11116.0 | 11116.0 | 10.44 | False | None | None | False | None | False | 116051.04 | 0 | | 3277290 | 113723 | None | code14 | First Floor | Cum | 11227.0 | 11227.0 | 62.0 | False | None | None | False | None | False | 696074.0 | 0 | | 3277291 | 113723 | None | code15 | Ground Floor | Cum | 12144.0 | 12144.0 | 67.23 | False | None | None | False | None | False | 816441.12 | 0 | | 3277292 | 113723 | None | code16 | First Floor | Cum | 12266.0 | 12266.0 | 20.1 | False | None | None | False | None | False | 246546.6 | 0 | | 3277293 | 113723 | None | code17 | Ground Floor | Cum | 11386.0 | 11386.0 | 56.26 | False | None | None | False | None | False | 640576.36 | 0 | | 3277294 | 113723 | None | code18 | First Floor | Cum | 11499.0 | 11499.0 | 8.08 | False | None | None | False | None | False | 92911.92 | 0 | | 3277295 | 113723 | None | code19 | Ground Floor | Cum | 11499.0 | 11499.0 | 8.08 | False | None | None | False | None | False | 92911.92 | 0 | | 3277296 | 113723 | None | code20 | Ground Floor | Cum | 7642.0 | 7642.0 | 66.55 | False | None | None | False | None | False | 508575.1 | 0 | | 3277297 | 113723 | None | code21 | Ground Floor | Sqm | 1467.0 | 1467.0 | 326.7 | False | None | None | False | None | False | 479268.9 | 0 | | 3277298 | 113723 | None | code22 | First Floor | Sqm | 1482.0 | 1482.0 | 575.15 | False | None | None | False | None | False | 852372.3 | 0 | | 3277299 | 113723 | None | code23 | Ground Floor | Sqm | 1249.0 | 1249.0 | 122.2 | False | None | None | False | None | False | 152627.8 | 0 | | 3277300 | 113723 | None | code24 | First Floor | Sqm | 1261.0 | 1261.0 | 46.34 | False | None | None | False | None | False | 58434.74 | 0 | | 3277301 | 113723 | None | code25 | Vol-1 Uni SR 2023-24 Building) Supplying fitting and placing TMT FE 550 / 550D steel reinforcement including cost of all materials, machinery, labour, cleaning, staightening, cutting, bending, hooking, laping / welding joints, tying with bining wire, / soft annealed steel wire and other ancilary operations complete as per drawing and techinical specification - Buildings (Page 18, Specification 2.11a.) | MT | 100192.0 | 100192.0 | 26.0 | False | None | None | False | None | False | 2604992.0 | 0 | | 3277302 | 113723 | None | code26 | Vol-2 Uni SR 2023-24 Building) Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete, fixed to openings with rawl plugs screws etc. using 10mm square rods @ approximate 5"c/c, outer frame with 1 1/4"x1/4" MS angle and including one coat metallic primer.(Weight per Sft not more than 1.5Kgs) as per approved design (Page 86, Specification 11.34B) | Kg | 205.0 | 205.0 | 1442.94 | False | None | None | False | None | False | 295802.7 | 0 | | 3277303 | 113723 | None | code27 | Vol-2 Uni SR 2023-24 Building) Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. Extra for providing mechanical device chain and crank operation for operating rolling shutters: Exceeding 16.80 m² in area including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge (Page 78 Specification 11.6.1 & 11.8.2) | Sqm | 4069.0 | 4069.0 | 10.8 | False | None | None | False | None | False | 43945.2 | 0 | | 3277304 | 113723 | None | code28 | Vol-2 Uni SR 2023-24 Building) Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. G.I. pipes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.(Page 84 Specification 11.26.3) | Kg | 207.0 | 207.0 | 914.0 | False | None | None | False | None | False | 189198.0 | 0 | | 3277305 | 113723 | None | code29 | Vol-2 Uni SR 2023-24 Building) Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (Page 82 Specification 11.16.2) | Kg | 165.0 | 165.0 | 12543.0 | False | None | None | False | None | False | 2069595.0 | 0 | | 3277306 | 113723 | None | code30 | Vol-2 Uni SR 2023-24 Building) Providing,fabricating and fixing Profiled Poly Urethane insulated Roof(PUF Sheet) having modular density 40kg/m2 and size 1.06m width and upto 7.60m length, 30mm thick sheets roof having external sheet of 0.5mm steel, bottom sheet of 0.40mm steel with powder coated finish. The precoated sheet shall be of minimum 240MPa steel conforming to IS 14246 : 1995 and shal have zinc coating with minimum 120gsm as per IS 277:1992,.The roofing system shall have suitable water proof over lapping arrangments and GRIHA ceritifed.The fasting shall be of self tapping screws of required length with PVC head along with washer pre-painted aluminium cap unit with build in seal arrangments. The entire roof shall be firmly fastened to the existng frame including all lead and lifts, loading & unloading ,usage charges of machinery and equipments, transportation charges,labour charges and all other incidental charges etc.,complete as per standard technical detailed specifications and as directed by the Engineer in charge. (Page 38 Specification 11.67.1) | Sqm | 2462.0 | 2462.0 | 665.83 | False | None | None | False | None | False | 1639273.46 | 0 | | 3277307 | 113723 | None | code31 | Vol-2 Uni SR 2023-24 Building) Extra for providing Manually operated Bevel Gear Box for operating rolling shutters including cost of materials, labour,usage charges of machinery complete as per specifications and as per directions of the Engineer-inCharge. (Page 79 Specification 11.8.3) | Each | 3456.0 | 3456.0 | 1.0 | False | None | None | False | None | False | 3456.0 | 0 | | 3277308 | 113723 | None | code32 | Vol-2 Uni SR 2023-24 Building) Providing Mathi/Nandi wood frames of doors, windows, clerestory windows, ventilators and other frames, (size 150mm x 75mm commercial sizes),wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications. (Page 99 Specification 12.12) | Cum | 139106.0 | 139106.0 | 1.07 | False | None | None | False | None | False | 148843.42 | 0 | | 3277309 | 113723 | None | code33 | First Floor | Cum | 139106.0 | 139106.0 | 0.35 | False | None | None | False | None | False | 48687.1 | 0 | | 3277310 | 113723 | None | code34 | Vol-2 Uni SR 2023-24 Building) Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemically treated hard wood battens and internal frame with minimum 45 mm wide wooden frame all round door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door using liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per specification 35 mm thick both side commercial (Page 105 Specification 12.57.6) | Sqm | 3721.0 | 3721.0 | 30.24 | False | None | None | False | None | False | 112523.04 | 0 | | 3277311 | 113723 | None | code36 | Vol-2 Uni SR 2023-24 Building) Providing and fixing in position fully panelled Honne wood shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. ( excluding cost of fixtures ) (Page 100 Specification 12.17) | Sqm | 7936.0 | 7936.0 | 4.2 | False | None | None | False | None | False | 33331.2 | 0 | | 3277312 | 113723 | None | code37 | First Floor | Sqm | 7935.0 | 7935.0 | 6.3 | False | None | None | False | None | False | 49990.5 | 0 | | 3277313 | 113723 | None | code38 | Vol-2 Uni SR 2023-24 Building) Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&Ps shall not be made) (Page 110 Specification 12.90) | Sqm | 7542.0 | 7542.0 | 18.72 | False | None | None | False | None | False | 141186.24 | 0 | | 3277314 | 113723 | None | code39 | First Floor | Sqm | 7542.0 | 7542.0 | 43.62 | False | None | None | False | None | False | 328982.04 | 0 | | 3277315 | 113723 | None | code40 | Vol-2 Uni SR 2023-24 Building) Providing& fixing of Openable window made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPV(Thermo Plastic Vulcanized) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the openable frame. The frame having overall size of 60mm x 55mm with GI reinforcement of 1mm thickness and openable sash with overall size of 60mm x 75mm and GI reinforcement of 1.5mm thickness. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 34 mm. Windows shall be provided with 5mm plain float glass, Standard hardware with friction hinge & Multi point locking system with Handle. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 900mm x 1819mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) (Page 112 Specification 12.91) | Sqm | 6858.0 | 6858.0 | 3.6 | False | None | None | False | None | False | 24688.8 | 0 | | 3277316 | 113723 | None | code41 | First Floor | Sqm | 6925.0 | 6925.0 | 1.08 | False | None | None | False | None | False | 7479.0 | 0 | | 3277317 | 113723 | None | code42 | Vol-2 Uni SR 2023-24 Building) Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (Page 42, Specification 8.9) | Sqm | 436.0 | 436.0 | 532.16 | False | None | None | False | None | False | 232021.76 | 0 | | 3277318 | 113723 | None | code43 | First Floor | Sqm | 440.0 | 440.0 | 97.27 | False | None | None | False | None | False | 42798.8 | 0 | | 3277319 | 113723 | None | code44 | Vol-2 Uni SR 2023-24 Building) Providing 20 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick/ stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge (Page 42, Specification 8.6.2) | Sqm | 485.0 | 485.0 | 1245.92 | False | None | None | False | None | False | 604271.2 | 0 | | 3277320 | 113723 | None | code45 | First Floor | Sqm | 491.0 | 491.0 | 809.06 | False | None | None | False | None | False | 397248.46 | 0 | | 3277321 | 113723 | None | code46 | Vol-2 Uni SR 2023-24 Building) Providing 20 mm external cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick/stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (Page 42, Specification 8.6.2) | Sqm | 485.0 | 485.0 | 419.52 | False | None | None | False | None | False | 203467.2 | 0 | | 3277322 | 113723 | None | code47 | First Floor | Sqm | 491.0 | 491.0 | 478.57 | False | None | None | False | None | False | 234977.87 | 0 | | 3277323 | 113723 | None | code48 | Vol-2 Uni SR 2023-24 Building) Providing Flush/ Ruled pointing: Pointing on stone work with cement mortar 1:3 (1 cement : 3 fine sand) after raking joints to depth nicely lin ing, including cost of materials, labour, curing as per specifications and as per directions of Engineer-in-charge (Page 44, Specification 8.19.1) | Sqm | 286.0 | 286.0 | 251.31 | False | None | None | False | None | False | 71874.66 | 0 | | 3277324 | 113723 | None | code49 | Vol-2 Uni SR 2023-24 Building) Providing and laying Vitrified tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 1000x1200 mm (Page 61, Specification 9.17.4) | Mtr | 2109.0 | 2109.0 | 37.88 | False | None | None | False | None | False | 79888.92 | 0 | | 3277325 | 113723 | None | code50 | First Floor | Sqm | 2109.0 | 2109.0 | 155.16 | False | None | None | False | None | False | 327232.44 | 0 | | 3277326 | 113723 | None | code51 | Vol-2 Uni SR 2023-24 Building) Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications.(Page 65, Specification 9.39) | Sqm | 1639.0 | 1639.0 | 26.52 | False | None | None | False | None | False | 43466.28 | 0 | | 3277327 | 113723 | None | code52 | First Floor | Mtr | 1655.0 | 1655.0 | 239.44 | False | None | None | False | None | False | 396273.2 | 0 | | 3277328 | 113723 | None | code53 | Vol-2 Uni SR 2023-24 Building) Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thick ness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. (Page 60, Specification 9.11) | Sqm | 1006.0 | 1006.0 | 53.79 | False | None | None | False | None | False | 54112.74 | 0 | | 3277329 | 113723 | None | code54 | First Floor | Sqm | 1016.0 | 1016.0 | 71.63 | False | None | None | False | None | False | 72776.08 | 0 | | 3277330 | 113723 | None | code55 | Vol-2 Uni SR 2023-24 Building) Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete.(Page 61, Specification 9.17.5) | Sqm | 1505.0 | 1505.0 | 247.23 | False | None | None | False | None | False | 372081.15 | 0 | | 3277331 | 113723 | None | code56 | First Floor | Sqm | 1520.0 | 1520.0 | 82.17 | False | None | None | False | None | False | 124898.4 | 0 | | 3277332 | 113723 | None | code57 | Vol-2 Uni SR 2023-24 Building) Providing and laying Polished Sadarahalli Grey Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 20 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. (Page 64, Specification 9.3.1) | Sqm | 2359.0 | 2359.0 | 336.01 | False | None | None | False | None | False | 792647.59 | 0 | | 3277333 | 113723 | None | code58 | First Floor | Sqm | 2382.0 | 2382.0 | 196.41 | False | None | None | False | None | False | 467848.62 | 0 | | 3277334 | 113723 | None | code59 | Vol-2 Uni SR 2023-24 Building) Providing and laying Black Lapotra Granite stone flooring in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing. and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. (Page 64, Specification 9.3.2) | Sqm | 2921.0 | 2921.0 | 5.19 | False | None | None | False | None | False | 15159.99 | 0 | | 3277335 | 113723 | None | code60 | Vol-2 Uni SR 2023-24 Building) Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar loca tions of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Area of slab over 0.50 m2 (Page 69, Specification 10.1.2) | Sqm | 4453.0 | 4453.0 | 23.25 | False | None | None | False | None | False | 103532.25 | 0 | | 3277336 | 113723 | None | code61 | Vol-2 Uni SR 2023-24 Building) Providing edge moulding to 18mm thick Granite stone counters, vanities etc including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-charge. (Page 69, Specification 10.2) | Mtr | 371.0 | 371.0 | 127.6 | False | None | None | False | None | False | 47339.6 | 0 | | 3277337 | 113723 | None | code62 | Vol-2 Uni SR 2023-24 Building) Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. (Page 62, Specification 9.20.4) | Sqm | 130.0 | 130.0 | 341.55 | False | None | None | False | None | False | 44401.5 | 0 | | 3277338 | 113723 | None | code63 | First Floor | Sqm | 131.0 | 131.0 | 548.4 | False | None | None | False | None | False | 71840.4 | 0 | | 3277339 | 113723 | None | code64 | Vol-2 Uni SR 2023-24 Building) Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 L/10 m² over and including one coat of Special primer applied @ 0.75 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (The gloss should be 50% @ 60 degree angle with 10 years life) (Page 46, Specification 8.33.1) | Sqm | 177.0 | 177.0 | 629.43 | False | None | None | False | None | False | 111409.11 | 0 | | 3277340 | 113723 | None | code65 | Vol-2 Uni SR 2023-24 Building) Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Special primer applied @ 0.75 ltr /10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (Page 46, Specification 8.33.1) | Sqm | 177.0 | 177.0 | 1725.57 | False | None | None | False | None | False | 305425.89 | 0 | | 3277341 | 113723 | None | code66 | Vol-2 Uni SR 2023-24 Building) Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 L/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (Page 45 Specification 8.29) | Sqm | 317.0 | 317.0 | 898.09 | False | None | None | False | None | False | 284694.53 | 0 | | 3277342 | 113723 | None | code67 | Vol-2 Uni SR 2023-24 Building) Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90L/10 m² over an under coat of primer applied @ 0.80 L/10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (Page 47 Specification 8.33.3) | Sqm | 156.0 | 156.0 | 914.0 | False | None | None | False | None | False | 142584.0 | 0 | | 3277343 | 113723 | None | code68 | Vol-2 Uni SR 2023-24 Building) Painting wood work with Deluxe Multi Surface Paint of required shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @0.75 ltr/10 m² of approved brand and manufacture to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge (Page 47 Specification 8.33.3) | Sqm | 156.0 | 156.0 | 49.77 | False | None | None | False | None | False | 7764.12 | 0 | | 3277344 | 113723 | None | code35 | First Floor | Sqm | 3721.0 | 3721.0 | 4.73 | False | None | None | False | None | False | 17600.33 | 0 |
| | 1718185433000 | 0 | None | None | Buildings | LANDSCAPE | 4119888.21 | | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
|---|
| 3277345 | 113724 | None | code01 | Excavation and refilling (Vol 1 Common SR for Engineering Departments - 23-24), (Page 5, Specification 1.1),(Page 7, Specification 1.9) | Cum | 365.0 | 365.0 | 20.88 | False | None | None | False | None | False | 7621.2 | 0 | | 3277346 | 113724 | None | code02 | PCC 1:4:8 below pedestal and tie beams (Vol 1 Common SR for Engineering Departments - 23-24), (Page 15, Specification 2.1.2) | Cum | 6532.0 | 6532.0 | 11.0 | False | None | None | False | None | False | 71852.0 | 0 | | 3277347 | 113724 | None | code03 | M25 Pedestal (Vol 1 Common SR for Engineering Departments - 23-24), (Page 15, Specification 2.2.2.1, Appendix 1, page 29,30) | Cum | 7867.0 | 7867.0 | 18.79 | False | None | None | False | None | False | 147820.93 | 0 | | 3277348 | 113724 | None | code04 | M25 RCC pier (Vol 1 Common SR for Engineering Departments - 23-24), (Page 17, Specification 2.5.2 Appendix 1, page 29,30) | Cum | 12904.0 | 12904.0 | 11.72 | False | None | None | False | None | False | 151234.88 | 0 | | 3277349 | 113724 | None | code05 | M25 grade beam (Vol 1 Common SR for Engineering Departments - 23-24), (Page 17, Specification 2.5.2 Appendix 1, page 29,30) | Cum | 12144.0 | 12144.0 | 17.82 | False | None | None | False | None | False | 216406.08 | 0 | | 3277350 | 113724 | None | code06 | M25 coping (Vol 1 Common SR for Engineering Departments - 23-24), (Page 17, Specification 2.5.2 Appendix 1, page 29,30) | Cum | 11006.0 | 11006.0 | 3.96 | False | None | None | False | None | False | 43583.76 | 0 | | 3277351 | 113724 | None | code07 | Reinforcing steel pedestals (Vol-2 Uni SR 2023-24 Building) , (Page 18, Specification 2.11a.) | Kg | 100.0 | 100.0 | 682.41 | False | None | None | False | None | False | 68241.0 | 0 | | 3277352 | 113724 | None | code08 | Reinforcing steel tie beams (Vol-2 Uni SR 2023-24 Building) , (Page 18, Specification 2.11a.) | Kg | 100.0 | 100.0 | 1988.01 | False | None | None | False | None | False | 198801.0 | 0 | | 3277353 | 113724 | None | code09 | Reinforcing steel coping (Vol-2 Uni SR 2023-24 Building) , (Page 18, Specification 2.11a.) | Kg | 100.0 | 100.0 | 169.88 | False | None | None | False | None | False | 16988.0 | 0 | | 3277354 | 113724 | None | code10 | 200 thick solid block masonry (Vol-2 Uni SR 2023-24 Building), (Page 17, Specification 6.32) | Sqm | 1467.0 | 1467.0 | 186.4 | False | None | None | False | None | False | 273448.8 | 0 | | 3277355 | 113724 | None | code11 | Recessed pointing (Vol-2 Uni SR 2023-24 Building), (Page 44, Specification 8.19.1) | Sqm | 255.0 | 255.0 | 410.08 | False | None | None | False | None | False | 104570.4 | 0 | | 3277356 | 113724 | None | code12 | Exterior emulsion paint (Vol-2 Uni SR 2023-24 Building),(Page 45 Specification 8.29) | Sqm | 317.0 | 317.0 | 410.08 | False | None | None | False | None | False | 129995.36 | 0 | | 3277357 | 113724 | None | code13 | Chain link mesh (Vol-2 Uni SR 2023-24 Building),(Page 96 Specification 11.6) Providing and fixing G.I. chain link fabric fencing of required width in mesh size 25x25 mm made of G.I. wire of dia 3 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge | Sqm | 893.0 | 893.0 | 237.6 | False | None | None | False | None | False | 212176.8 | 0 | | 3277358 | 113724 | None | code14 | MS Angle supports and frame for chain link mesh (Vol-2 Uni SR 2023-24 Building),(Page 82 Specification 11.25.2) | Kg | 136.0 | 136.0 | 1980.0 | False | None | None | False | None | False | 269280.0 | 0 | | 3277359 | 113724 | None | code15 | Providing and making MS gates 5.5m wide x 2.1m high with main frame and boxing in 12G MS box sections and cast iron inserts as per design (Vol-2 Uni SR 2023-24 Building),(Page 82 Specification 11.25.2) | Kg | 136.0 | 136.0 | 2118.0 | False | None | None | False | None | False | 288048.0 | 0 | | 3277360 | 113724 | None | code16 | Mechanical levelling of land for landscape with available soil (Vol 1 Common SR for Engineering Departments - 23-24),(Page 5, Specification 1.1) | Sqm | 91.0 | 91.0 | 2820.0 | False | None | None | False | None | False | 256620.0 | 0 | | 3277361 | 113724 | None | code17 | Providing and laying 60mm thick factory made cement concrete paver block of approved shape and colour of M -30 grade made of C&D waste by block making machine with vibratory compaction laid in required pattern and including over 50mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge (Vol-2 Uni SR 2023-24 Building),(Page 63 Specification 9.25) | Sqm | 800.0 | 800.0 | 2079.0 | False | None | None | False | None | False | 1663200.0 | 0 |
|
|
|---|