1718085896000 | 0 | None | None | Buildings | CONSTRUCTION OF LADIES REST ROOM AT MAVINAKURVE IN BHATKAL TALUK OF U.K.DISTRICT | 5868234.47 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3264612 | 113099 | None | 1.12 | Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading,caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. in all kinds of soils upto 3m depth (PWD SR 2023-24,Vol-1 Page No:8, Item No. 1.12) | Cum | 106.4 | 106.4 | 60.0 | False | None | None | False | None | False | 6384.0 | 0 | 3264613 | 113099 | None | 1.14.1 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. in all kinds of soils depth upto 3m (PWD SR 2023-24 Volume-1 Page No 08 Item No 1.14.1) | Cum | 114.24 | 114.24 | 318.0 | False | None | None | False | None | False | 36328.32 | 0 | 3264614 | 113099 | None | 2.1.2 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates (PWD SR 2023-24 Volume-1 Page No 15 Item No 2.1.2) | Cum | 6343.68 | 6343.68 | 33.0 | False | None | None | False | None | False | 209341.44 | 0 | 3264615 | 113099 | None | 1.9 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m(PWD SR 2023-24 Volume-1 Page No 7 Item No1.9) | Cum | 297.92 | 297.92 | 94.0 | False | None | None | False | None | False | 28004.48 | 0 | 3264616 | 113099 | None | 2.2.3 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery,curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm and nominal size graded crushed coarse aggregates(PWD SR 2023-24 Vol 1 Page No 15 SI. No 2.2.3)Footing | Cum | 7664.03 | 7664.03 | 66.0 | False | None | None | False | None | False | 505825.98 | 0 | 3264617 | 113099 | None | 2.5.2 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 design mix using 20mm nominal size graded crushed coarse aggregate (PWD SR 2023-24 Vol 1 Page No 16 SI. No 2.5.2)Column | Cum | 13029.07 | 13029.07 | 15.0 | False | None | None | False | None | False | 195436.05 | 0 | 3264618 | 113099 | None | 2.2.3 | Providing and laying in position Cement Concrete for all Foundation works.The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes,labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (PWD SR 2023-24 Vol 1 Page No 15 SI. No 2.2.3)Plinth Beam | Cum | 10644.48 | 10644.48 | 12.0 | False | None | None | False | None | False | 127733.76 | 0 | 3264619 | 113099 | None | 2.5.2 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes ,labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (PWD SR 2023-24 Vol 1 Page No 16 SI. No 2.5.2)Lintel &Roof beam | Cum | 12262.66 | 12262.66 | 16.0 | False | None | None | False | None | False | 196202.56 | 0 | 3264620 | 113099 | None | 2.5.2 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes ,labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (PWD SR 2023-24 Vol 1 Page No 16 SI. No 2.5.2)Slab | Cum | 11496.24 | 11496.24 | 33.0 | False | None | None | False | None | False | 379375.92 | 0 | 3264621 | 113099 | None | 2.11 a | Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) Buildings (PWD SR 2023-24 Vol 1 Page No 18 SI. No 2.11a) | Tonne | 100191.84 | 100191.84 | 15.75 | False | None | None | False | None | False | 1578021.48 | 0 | 3264622 | 113099 | None | 5.5 | Providing and constructing laterite size stone masonry including cost and conveyance of all materials curing etc complete as per specification I.S. 3620/1979 having compressive strength not less than 3.5 N/mm2 for saturated dry samples - For Foundation in CM 1:6.(PWD SR Vol 2 Page No 9 Sl. No. 5.5) | Cum | 7138.88 | 7138.88 | 16.0 | False | None | None | False | None | False | 114222.08 | 0 | 3264623 | 113099 | None | 5.7 | Providing and constructing laterite size stone masonry including cost and conveyance of all materials curing etc complete as per specification I.S. 3620/1979 having compressive strength not less than 3.5 N/mm2 for saturated dry samples - For Super structure in CM 1:6. ( PWD SR 2023-24 Vol 2 Page No 9 Sl. No.5.7) | Cum | 7565.6 | 7565.6 | 65.0 | False | None | None | False | None | False | 491764.0 | 0 | 3264624 | 113099 | None | 8.4.1 | Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:3 (1 cement: 3 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing caffolding, including cost of materials, labour, curing omplete as per specifications and as per directions of Engineer-in-charge.(PWD SR 2023-24 Vol 2 Page No 41 Sl. No 8.4.1) | Sqm | 361.76 | 361.76 | 232.0 | False | None | None | False | None | False | 83928.32 | 0 | 3264625 | 113099 | None | 8.2.2 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (PWD SR 2023-24 Vol 2 Page No 41 Sl. No 8.2.2) | Sqm | 312.48 | 312.48 | 177.0 | False | None | None | False | None | False | 55308.96 | 0 | 3264626 | 113099 | None | 8.5.2 | Providing 15 mm cement plaster on rough side of single or half brickwall finished with a floating coat of neat cement of mix: 1:4 (1 cement:4 fine sand) to brick masonry including rounding off corners wherever require smooth rendering, providing and removing scaffolding, includingcost of materials, labour, curing complete as per specifications and as perdirections of Engineer-in-charge.(PWD SR 2023-24 Vol 2 Page No 42 Sl. No 8.5.2) | Sqm | 390.88 | 390.88 | 244.0 | False | None | None | False | None | False | 95374.72 | 0 | 3264627 | 113099 | None | 8.51 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. (PWD SR 2023-24 Vol 2 Page No 50. It. No 8.51) | Sqm | 112.0 | 112.0 | 476.0 | False | None | None | False | None | False | 53312.0 | 0 | 3264628 | 113099 | None | 8.3.2 | Providing 20 mm cement plaster of mix :1:6 (1 cement: 6 fine sand) to brick/stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (PWD SR 2023-24 Vol 2 Page No 41 Sl. No 8.3.2) | Sqm | 372.96 | 372.96 | 339.0 | False | None | None | False | None | False | 126433.44 | 0 | 3264629 | 113099 | None | 8.10 | Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge(PWD SR 2023-24 Vol 2 Page No 43 Sl. No 8.10) | Sqm | 236.32 | 236.32 | 27.0 | False | None | None | False | None | False | 6380.64 | 0 | 3264630 | 113099 | None | 9.12.1 | Providing and laying vitrified floor tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 500x500 mm (PWD SR 2023-24 Vol 2 Page No 60 Sl. No 9.12.1) | Sqm | 1211.84 | 1211.84 | 136.0 | False | None | None | False | None | False | 164810.24 | 0 | 3264631 | 113099 | None | 9.11 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming toIS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2including pointing the joints with white cement and matching pigments etc., complete.(PWD SR 2023-24 V-2 Page No 60,It no 9.11) | Sqm | 995.68 | 995.68 | 49.0 | False | None | None | False | None | False | 48788.32 | 0 | 3264632 | 113099 | None | 9.39 | Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications.(V-2 Page No 65,It no 9.39 SR2023-24) | Sqm | 1622.88 | 1622.88 | 177.0 | False | None | None | False | None | False | 287249.76 | 0 | 3264633 | 113099 | None | 8.25 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (PWD SR 2023-24 Vol 2, Page No 45 Sl. No 8.25) | Sqm | 153.44 | 153.44 | 476.0 | False | None | None | False | None | False | 73037.44 | 0 | 3264634 | 113099 | None | 8.30 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 Itr/10 m2 over and including priming coat of exterior primer applied @ 2.20 kg/10 m2) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in- charge. (PWD SR 2023-24 Vol 2, Page No 46 Sl. No 8.30) | Sqm | 194.88 | 194.88 | 339.0 | False | None | None | False | None | False | 66064.32 | 0 | 3264635 | 113099 | None | 12.90 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) (PWD SR 2023-24 Vol 2, Page No 112 Sl. No 12.90) | Sqm | 7542.08 | 7542.08 | 16.2 | False | None | None | False | None | False | 122181.696 | 0 | 3264636 | 113099 | None | 12.12 | Providing Mathi or Nandi wood frames of Doors,windows,clerestory windows,ventilators and other frames,wrought,framed of assembled including making plaster of grooves (excluding cost of cement concrete and side clamps) but including cost of materials, labour,usage charges complete as per specifications.(PWD SR 2023-24 I.No.12.12 P.No.100 Of Vol.2,) | Cum | 139106.24 | 139106.24 | 0.17 | False | None | None | False | None | False | 23648.0608 | 0 | 3264637 | 113099 | None | 12.21 | Providing and fixing in position fully panelled Matti/Nandi wood shutters for doors with , stiles and rails of 30mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. (excluding cost of fixtures) (PWD SR 2023-24 Vol 2, Page No 100 Sl. No 12.21) | Sqm | 6431.04 | 6431.04 | 8.3 | False | None | None | False | None | False | 53377.632 | 0 | 3264638 | 113099 | None | 12.54 | Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge. (PWD SR 2023-24 Vol 2, Page No 104 Sl. No 12.54) | Mtr | 356.16 | 356.16 | 39.6 | False | None | None | False | None | False | 14103.936 | 0 | 3264639 | 113099 | None | 12.55.1 | Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges. (PWD SR 2023-24 Vol 2, Page No 104 Sl. No 12.55.1) | Sqm | 2649.92 | 2649.92 | 12.6 | False | None | None | False | None | False | 33388.992 | 0 | 3264640 | 113099 | None | 12.85 | Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) (PWD SR 2023-24 Vol 2, Page No 109 Sl. No 12.85) | Sqm | 6405.28 | 6405.28 | 3.0 | False | None | None | False | None | False | 19215.84 | 0 | 3264641 | 113099 | None | 11.34 B | Providing and fixing M.S. grills of required pattern in frames of win- dows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc. (PWD SR 2023-24 Vol 2, Page No 86 Sl. No 11.34B) | Kg | 204.96 | 204.96 | 272.0 | False | None | None | False | None | False | 55749.12 | 0 | 3264642 | 113099 | None | 8.40 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (PWD SR 2023-24 Vol 2, Page No 48 it. No 8.40) | Sqm | 128.8 | 128.8 | 30.0 | False | None | None | False | None | False | 3864.0 | 0 | 3264643 | 113099 | None | 15.1 | Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge.(PWD SR 2023-24 Vol 2, Page No 149 Sl. No 15.1) | Sqm | 915.04 | 915.04 | 168.0 | False | None | None | False | None | False | 153726.72 | 0 | 3264644 | 113099 | None | 14.1.1 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required. White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests (PWD SR2023-24 Vol 2, Page No 131 Sl. No 14.1.1) | Each | 5470.08 | 5470.08 | 4.0 | False | None | None | False | None | False | 21880.32 | 0 | 3264645 | 113099 | None | 14.3.2 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked black solid plastic seat and lid (PWD SR2023-24 Vol 2, Page No 131 Sl. No 14.3.2) | Each | 6501.6 | 6501.6 | 4.0 | False | None | None | False | None | False | 26006.4 | 0 | 3264646 | 113099 | None | 14.7 A | Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required: using White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer (PWD SR 2023-24 Vol 2, Page No 133 Sl. No 14.7A) | Each | 4615.52 | 4615.52 | 4.0 | False | None | None | False | None | False | 18462.08 | 0 | 3264647 | 113099 | None | 14.31 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.( PWD SR 2023-24 I.No.14.31 P.No.136 Vol.2 ) | Each | 1366.4 | 1366.4 | 2.0 | False | None | None | False | None | False | 2732.8 | 0 | 3264648 | 113099 | None | 14.40.2 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 g.(PWD SR 2023-24 Vol 2, Page No 137 Sl. No 14.40.2) | Each | 535.36 | 535.36 | 4.0 | False | None | None | False | None | False | 2141.44 | 0 | 3264649 | 113099 | None | 12.60 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. (PWD SR 2023-24 Vol 2, Page No 105, Sl. No. 12.60) | No | 1178.24 | 1178.24 | 3.0 | False | None | None | False | None | False | 3534.72 | 0 | 3264650 | 113099 | None | 12.62 | Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. complete (PWD SR 2023-24 Vol 2, Page No 105 Sl. No 12.62) | No | 265.44 | 265.44 | 6.0 | False | None | None | False | None | False | 1592.64 | 0 | 3264651 | 113099 | None | 12.63 | Providing and fixing aluminium tower bolts, ISI marked, anodised (an odic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete (PWD SR 2023-24 Vol 2, Page No 105 Sl. No 12.63) | No | 145.6 | 145.6 | 4.0 | False | None | None | False | None | False | 582.4 | 0 | 3264652 | 113099 | None | 13.4.2 | Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) 32 mm nominal bore (PWD SR 2023-24 Vol 2, Page No 117 Sl No 13.4.2) | No | 669.76 | 669.76 | 2.0 | False | None | None | False | None | False | 1339.52 | 0 | 3264653 | 113099 | None | 13.2.2 | Providing and fixing brass bib cock of approved quality: 20 mm nominal bore (PWD SR 2023-24 Vol 2, Page No 117 Sl. No 13.2.2) | No | 341.6 | 341.6 | 16.0 | False | None | None | False | None | False | 5465.6 | 0 | 3264654 | 113099 | None | 13.3.2 | Providing and fixing brass stop cock of approved quality: 20 mm nominal bore (PWD SR 2023-24 Vol 2, Page No 117 Sl. No 13.3.2) | No | 341.6 | 341.6 | 12.0 | False | None | None | False | None | False | 4099.2 | 0 | 3264655 | 113099 | None | 1.6.1 | Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work. in all kinds of soils depth upto 1.5 m (PWD SR 2023-24 Vol 1, Page No 6 Item No 1.6.1) | Mtr | 542.08 | 542.08 | 40.5 | False | None | None | False | None | False | 21954.24 | 0 | 3264656 | 113099 | None | 10.14.9 | Providing and installing at site of work P.V.C. pipes including cost of pipes and specials and labour, including lowering into trenches, laying true to line, level and perfect linking at joints leak proof including jointing of approved type with all labour charges and all lift charges, handling charges including encasing the pipe around to a depth not less than 15 cms with gravel or selected earth available from the excavation etc. 75mm (weight of pipe=0.917 Kg) complete.(PWD SR 2023-24 Vol.5 page no. 120 Sl no-10.14.9) | Rmtr | 215.04 | 215.04 | 35.0 | False | None | None | False | None | False | 7526.4 | 0 | 3264657 | 113099 | None | 10.14.11 | Providing and installing at site of work P.V.C. pipes including cost of pipes and specials and labour, including lowering into trenches, laying true to line, level and perfect linking at joints leak proof including jointing of approved type with all labour charges and all lift charges, handling charges including encasing the pipe around to a depth not less than 15 cms with gravel or selected earth available from the excavation etc. complete.110 mm (weight of pipe=1.894 Kg) (PWD SR 2023-24 Vol.5 page no. 120 Sl no-10.14.11) | Mtr | 400.96 | 400.96 | 100.0 | False | None | None | False | None | False | 40096.0 | 0 | 3264658 | 113099 | None | 655 | Providing, fixing, applying of contraction joint with suitable type PVC water stopper,PVC pipe - OD 50mm and 6 Kg/sqcm(PWD SR 2023-24 Vol.5 page no. A44 Sl no-655)
| Mtr | 58.24 | 58.24 | 30.0 | False | None | None | False | None | False | 1747.2 | 0 | 3264659 | 113099 | None | 13.34 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow
pipes but without fittings and the base support for tank. (PWD SR 2023-24 Volume 2, P.No. 123,It.No.13.34 ) | Ltr | 10.08 | 10.08 | 2000.0 | False | None | None | False | None | False | 20160.0 | 0 | 3264660 | 113099 | None | 13.8.1 | Providing, Single Phase Submersible Pump Sets of 100mm dia (4 inch) suitable for bore well confirming to IS 8034-2000 specifications, to work site with testing of as per instructions of engineer incharge of work and.latest amendments etc .Compleete(PWD SR 2023-24 Vol.5 page no. 150 Sl no-13.8.1) | Each | 18491.2 | 18491.2 | 1.0 | False | None | None | False | None | False | 18491.2 | 0 | 3264661 | 113099 | None | 13.22.4 | Supply and delivery at site Brand new best make PVC insulated cable of Flat 3 core (sheathed) of nominal cross sectional area as per IS 694-1990 with ISI Mark and as per its latest amendments.(PWD SR 2023-24 Vol.5 Sl. no -13.22.4 , P- 154) | Mtr | 207.2 | 207.2 | 100.0 | False | None | None | False | None | False | 20720.0 | 0 | 3264662 | 113099 | None | 13.32 | Labour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all items including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges,tools and equipments etc., involved in the job as per specifications, with necessary tests as per specifications, with testing of as per instructions of engineer incharge of work (PWD SR 2023-24 Vol.5 Sl. no -13.32 , P- 156) | Job | 7280.0 | 7280.0 | 1.0 | False | None | None | False | None | False | 7280.0 | 0 | 3264663 | 113099 | None | 16.9 | Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover. (PWD SR 2023-24 Vol 5,SL.No 16.9 Page No.191) | Each | 6108.48 | 6108.48 | 6.0 | False | None | None | False | None | False | 36650.88 | 0 | 3264664 | 113099 | None | 13.32.2 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.20mm nominal dia piles (PWD SR 2023-24 V-2 Page No 122,It no 13.32.2) | m | 424.48 | 424.48 | 45.0 | False | None | None | False | None | False | 19101.6 | 0 | 3264665 | 113099 | None | 13.33.3 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply including all CPVCplain & brass threaded fittings This includes jointing of pipes & fittingswith one step CPVC solvent cement, trenching, refilling & testing of jointscomplete as per direction of Engineer in Charge. External work 25mm Nominal dia piles (PWD SR 2023-24 V-2 Page No 122,It no 13.33.3) | m | 331.52 | 331.52 | 30.0 | False | None | None | False | None | False | 9945.6 | 0 | 3264666 | 113099 | None | 13.33.4 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply including all CPVCplain & brass threaded fittings This includes jointing of pipes & fittingswith one step CPVC solvent cement, trenching, refilling & testing of jointscomplete as per direction of Engineer in Charge. External work32 mm nominal dia piles (PWD SR 2023-24 V-2 Page No 123,It no 13.33.4) | m | 416.64 | 416.64 | 45.0 | False | None | None | False | None | False | 18748.8 | 0 | 3264667 | 113099 | None | 13.33.6 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply including all CPVCplain & brass threaded fittings This includes jointing of pipes & fittingswith one step CPVC solvent cement, trenching, refilling & testing of jointscomplete as per direction of Engineer in Charge. External work50mm nominal dia piles (PWD SR 2023-24 V-2 Page No 123,It no 13.33.6) | m | 807.52 | 807.52 | 185.0 | False | None | None | False | None | False | 149391.2 | 0 |
|