tenderSubEstimateList | createdTs | version | createdDate | modifiedDate | workCategoryName | subEstimateName | estimateTotal | itemList |
---|
1718022464000 | 0 | None | None | Buildings | GROUND FLOOR(CIVIL WORKS) | 271999902.69 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3261875 | 113003 | None | V-3 P.No 7 It.No 2.5A | Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness.By Mechanical Means using Dozer In area of light jungle
| Sqm | 486.93 | 486.93 | 74.9 | False | None | None | False | None | False | 36471.057 | 0 | 3261876 | 113003 | None | V-1 P.No 8 It.No 1.12 | Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work.
| Cum | 117.71 | 117.71 | 2246.88 | False | None | None | False | None | False | 264480.2448 | 0 | 3261877 | 113003 | None | V-1 P.No 8 It.No 1.14.1 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m
| Cum | 126.38 | 126.38 | 11504.22 | False | None | None | False | None | False | 1453903.3236 | 0 | 3261878 | 113003 | None | V-1 P.No 8 It.No 1.15.1 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In ordinary/soft rock without blasting upto 1.5 m depth
| Cum | 449.76 | 449.76 | 1980.41 | False | None | None | False | None | False | 890709.2016 | 0 | 3261879 | 113003 | None | V-3 P.No 3 It.No 1.1A | Loading and Unloading of Stone Boulder/Stone aggregates/ Sand/Kankar/Moorum
| Cum | 167.27 | 167.27 | 8732.09 | False | None | None | False | None | False | 1460616.6943 | 0 | 3261880 | 113003 | None | V-2 P.No 5 It.No 4.1 | Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications.
| Sqm | 146.2 | 146.2 | 5275.0 | False | None | None | False | None | False | 771205.0 | 0 | 3261881 | 113003 | None | V-1 P.No 7 It.No 1.9 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
| Cum | 329.57 | 329.57 | 7190.14 | False | None | None | False | None | False | 2369654.4398 | 0 | 3261882 | 113003 | None | V-1 P.No 7 It.No 1.8 | Construction of Embankment by excavating the available approved Gravel/ Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work.
| Cum | 587.29 | 587.29 | 11759.31 | False | None | None | False | None | False | 6906125.1699 | 0 | 3261883 | 113003 | None | V-1 P.No 15 It.No 2.1.3 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates. Including FormWork
| Cum | 7420.37 | 7420.37 | 1619.45 | False | None | None | False | None | False | 12016918.1965 | 0 | 3261884 | 113003 | None | V-1 P.No 15 It.No 2.2.5 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, The cost includes Form work, lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
| Cum | 8696.44 | 8696.44 | 5432.23 | False | None | None | False | None | False | 47241062.2612 | 0 | 3261885 | 113003 | None | V-1 P.No 15 It.No 2.2.5 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, The cost includes Form work, lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
| Cum | 8857.49 | 8857.49 | 6.73 | False | None | None | False | None | False | 59610.9077 | 0 | 3261886 | 113003 | None | V-1 P.No 16 It.No 2.5.5 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes Form work, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars to be paid separately) M40 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
(COLUMNS) | Cum | 15843.59 | 15843.59 | 725.61 | False | None | None | False | None | False | 11496267.3399 | 0 | 3261887 | 113003 | None | V-1 P.No 17 It.No 2.5.5 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes Form work, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars to be paid separately) M40 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(LIFT CORE WALLS)
| Cum | 15843.59 | 15843.59 | 82.98 | False | None | None | False | None | False | 1314701.0982 | 0 | 3261888 | 113003 | None | V-1 P.No 17 It.No 2.5.5 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes Form work, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars to be paid separately) M40 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
| Cum | 13979.64 | 13979.64 | 526.01 | False | None | None | False | None | False | 7353430.4364 | 0 | 3261889 | 113003 | None | V-1 P.No 17 It.No 2.5.5 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes Form work, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars to be paid separately) M40 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
| Cum | 14911.61 | 14911.61 | 550.18 | False | None | None | False | None | False | 8204069.5898 | 0 | 3261890 | 113003 | None | V-1 P.No 17 It.No 2.5.5 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes Form work, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars to be paid separately) M40 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
| Cum | 13979.64 | 13979.64 | 861.25 | False | None | None | False | None | False | 12039964.95 | 0 | 3261891 | 113003 | None | V-1 P.No 17 It.No 2.5.5 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes Form work, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars to be paid separately) M40 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
(STAIRCASE) | Cum | 13979.64 | 13979.64 | 38.21 | False | None | None | False | None | False | 534162.0444 | 0 | 3261892 | 113003 | None | V-1 P.No 17It.No 2.5.5 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes Form work, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars to be paid separately) M40 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(LINTELS)
| Cum | 14911.61 | 14911.61 | 21.05 | False | None | None | False | None | False | 313889.3905 | 0 | 3261893 | 113003 | None | V-1 P.No 16 It.No 2.5.1 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork | Cum | 11911.13 | 11911.13 | 26.37 | False | None | None | False | None | False | 314096.4981 | 0 | 3261894 | 113003 | None | V-2P43I8.16 a | Providing lath plaster with cement mortar 1:3, 5cms thick with 6mm dia mild steel bars at 20 cms. c to c both horizontally and vertically fixed with chicken mesh for drop chajja,facia, backing to cup boards including cost of all materials, labour, providing and removing form work usage charges, curing, complete as per specifications. | Sqm | 1533.88 | 1533.88 | 31.05 | False | None | None | False | None | False | 47626.974 | 0 | 3261895 | 113003 | None | V-1 P.No 18 It.No 2.11 a | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.
| Tonne | 110837.22 | 110837.22 | 803.12 | False | None | None | False | None | False | 89015588.1264 | 0 | 3261896 | 113003 | None | 18-19 SR P.No 15 It.No 4.21 | Extra for providing throating or drip moulding to RCC chejjas with plastering ( labour charges only ) as per specifications.
| Rmtr | 38.94 | 38.94 | 650.7 | False | None | None | False | None | False | 25338.258 | 0 | 3261897 | 113003 | None | V-1Page8Itm1.15.1 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In ordinary/soft rock without blasting upto 1.5 m depth
| Cum | 526.58 | 526.58 | 899.58 | False | None | None | False | None | False | 473700.8364 | 0 | 3261898 | 113003 | None | V-2 P.No 9 It.No 5.4 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)
| Cum | 7915.97 | 7915.97 | 307.98 | False | None | None | False | None | False | 2437960.4406 | 0 | 3261899 | 113003 | None | V-2 P.No 17 It.No 6.32 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.
| Sqm | 1623.09 | 1623.09 | 4423.03 | False | None | None | False | None | False | 7178975.7627 | 0 | 3261900 | 113003 | None | V-2 P.No 17 It.No 6.34 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.
| Sqm | 1367.86 | 1367.86 | 445.54 | False | None | None | False | None | False | 609436.3444 | 0 | 3261901 | 113003 | None | V-2 P.No 105 It.No 12.57.6 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification.-do- 35 mm thick both side Commercial
| Sqm | 4115.96 | 4115.96 | 225.0 | False | None | None | False | None | False | 926091.0 | 0 | 3261902 | 113003 | None | V-2 P.No 100 It.No 12.13.1 | Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications.
| Cum | 122431.79 | 122431.79 | 7.11 | False | None | None | False | None | False | 870490.0269 | 0 | 3261903 | 113003 | None | V-2 P.No 105 It.No 12.51 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications.
| No | 1258.82 | 1258.82 | 82.0 | False | None | None | False | None | False | 103223.24 | 0 | 3261904 | 113003 | None | V-2 P.No 218 It.No 22.15.2 | Providing and fixing Stainless Steel Fixtures conforming to 304
graded steel as per direction of engineer in charge.SS Handles 300mm
| No | 681.45 | 681.45 | 164.0 | False | None | None | False | None | False | 111757.8 | 0 | 3261905 | 113003 | None | V-2 P.No 219 It.No 22.15.4 | Providing and fixing Stainless Steel Fixtures conforming to 304
graded steel as per direction of engineer in charge.SS Aldrop 16mm dia, 300mm
| No | 464.63 | 464.63 | 82.0 | False | None | None | False | None | False | 38099.66 | 0 | 3261906 | 113003 | None | V-2 P.No 219 It.No 22.15.6 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Tower Bolts 200x10mm
| No | 185.85 | 185.85 | 164.0 | False | None | None | False | None | False | 30479.4 | 0 | 3261907 | 113003 | None | V-2 P.No 219 It.No 22.15.9 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS hinges 100 mm
| No | 86.73 | 86.73 | 328.0 | False | None | None | False | None | False | 28447.44 | 0 | 3261908 | 113003 | None | V-2 P.No 219 It.No 22.15.10 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Door stopper 75mm
| No | 123.9 | 123.9 | 82.0 | False | None | None | False | None | False | 10159.8 | 0 | 3261909 | 113003 | None | V-2 P.No 105 It.No 12.60 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.
| No | 1303.43 | 1303.43 | 82.0 | False | None | None | False | None | False | 106881.26 | 0 | 3261910 | 113003 | None | V-2 P.No 69 It.No 10.6.3 | Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm
| No | 74.34 | 74.34 | 492.0 | False | None | None | False | None | False | 36575.28 | 0 | 3261911 | 113003 | None | V-2p205itm20.79 | Supplying and fixing new teak wood beads wherever necessary including cost of materials, labour, complete as per specifications. | Rmtr | 64.43 | 64.43 | 487.35 | False | None | None | False | None | False | 31399.9605 | 0 | 3261912 | 113003 | None | V-2 P.No 110 It.No 12.90 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall
be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)
| Sqm | 8343.43 | 8343.43 | 216.45 | False | None | None | False | None | False | 1805935.4235 | 0 | 3261913 | 113003 | None | V-2 P.No 109 It.No 12.85 | Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)
| Sqm | 7085.84 | 7085.84 | 90.72 | False | None | None | False | None | False | 642827.4048 | 0 | 3261914 | 113003 | None | V-2 P.No 86 It.No 11.34A | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding
| Kg | 208.15 | 208.15 | 6450.57 | False | None | None | False | None | False | 1342686.1455 | 0 | 3261915 | 113003 | None | V-2 P.No 111 It.No 12.93.1 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately)Size 62 x 100mm
| Rmtr | 869.78 | 869.78 | 99.2 | False | None | None | False | None | False | 86282.176 | 0 | 3261916 | 113003 | None | V-2 P.No 112 It.No 12.94.1 | Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately)30 mm thickness
| Sqm | 4317.92 | 4317.92 | 30.72 | False | None | None | False | None | False | 132646.5024 | 0 | 3261917 | 113003 | None | V-2 P.No 107 It.No 12.59 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete.
| No | 1380.25 | 1380.25 | 92.0 | False | None | None | False | None | False | 126983.0 | 0 | 3261918 | 113003 | None | V-2 P.No 109 It.No 11.25.2 | Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.
| Kg | 168.5 | 168.5 | 504.0 | False | None | None | False | None | False | 84924.0 | 0 | 3261919 | 113003 | None | V-2 P.No 41 It.No 8.4.2 | Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( Inside)
| Sqm | 386.57 | 386.57 | 7516.37 | False | None | None | False | None | False | 2905603.1509 | 0 | 3261920 | 113003 | None | V-2 P.No 43 It.No 8.10 | Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 261.43 | 261.43 | 7640.71 | False | None | None | False | None | False | 1997510.8153 | 0 | 3261921 | 113003 | None | V-2 P.No 50 It.No 8.51 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.
| Sqm | 123.9 | 123.9 | 15157.1 | False | None | None | False | None | False | 1877964.69 | 0 | 3261922 | 113003 | None | V-2 P.No 42 It.No 8.5.2 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( Outside)
| Sqm | 432.41 | 432.41 | 1254.78 | False | None | None | False | None | False | 542579.4198 | 0 | 3261923 | 113003 | None | V-2 P.No 41 It.No 8.3.1 | Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per direc- tions of Engineer-in-charge.
| Sqm | 438.61 | 438.61 | 217.63 | False | None | None | False | None | False | 95454.6943 | 0 | 3261924 | 113003 | None | V-2 P.No 43 It.No 8.16.2 | Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment.Plaster mesh 150mm wide
| Rmtr | 47.08 | 47.08 | 4200.0 | False | None | None | False | None | False | 197736.0 | 0 | 3261925 | 113003 | None | 18-19 SR P.No 69 It.No 10.5.2 | Bore Packing : Filling the bore wherever necessary with polymer modified concrete and brushing one coat of acrylic copolymer cross linked formulaion on the bore. Including all labour charges tools and equipments, all complete as per the manufacturer.
| Sqm | 283.2 | 283.2 | 50.0 | False | None | None | False | None | False | 14160.0 | 0 | 3261926 | 113003 | None | V-2 P.No 54 It.No 8.79 | Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove.
| Rmtr | 64.43 | 64.43 | 1427.8 | False | None | None | False | None | False | 91993.154 | 0 | 3261927 | 113003 | None | V-2 P.No 61 It.No 9.17.2 | Providing and laying Vitrified tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600x600 mm
| Sqm | 1455.83 | 1455.83 | 4229.93 | False | None | None | False | None | False | 6158058.9919 | 0 | 3261928 | 113003 | None | V-2 P.No 59 It.No 9.1 | Providing and laying Cement concrete flooring 40 mm thick with 20 mm nominal size stone aggregate using 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry complete.
| Sqm | 558.79 | 558.79 | 540.0 | False | None | None | False | None | False | 301746.6 | 0 | 3261929 | 113003 | None | V-2 P.No 62 It.No 9.22.2 | Providing and laying Polished Glazed Vitrified tiles with thickness 10 mm in floor with different sizes with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).Size of Tile 600x600 mm
| Sqm | 1642.91 | 1642.91 | 2022.68 | False | None | None | False | None | False | 3323081.1988 | 0 | 3261930 | 113003 | None | V-2 P.No 63 It.No 9.24 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.
** Polished Granite stone slab Black, Cat Eye, River Pink or equivalent.
| Sqm | 3533.63 | 3533.63 | 578.2 | False | None | None | False | None | False | 2043144.866 | 0 | 3261931 | 113003 | None | V-2 P.No 64 It.No 9.32 | Providing and laying Black Lapotra Granite stone flooring in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. | Sqm | 3199.1 | 3199.1 | 218.5 | False | None | None | False | None | False | 699003.35 | 0 | 3261932 | 113003 | None | V-2 P.No 41 It.No 8.2.1 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 365.51 | 365.51 | 2624.6 | False | None | None | False | None | False | 959317.546 | 0 | 3261933 | 113003 | None | V-2 P.No 150 It.No 15.7 | Providing and supplying crystalline integral concrete waterproofing admixture that waterproofs concrete by forming crystals deep in the pores, capillaries and microcracks of the concrete, self-seal waterproofing compound to bridge shrinkage cracks upto 0.5mm in width & resist hydro-static pressure upto 16bar for both positive & negative pressure confirming to DIN 1048 part 5 for 56% reduction in depth of penetration against control, resistance to chloride penetration confirming to ASTM C 1202 with 64% improvement against control & protecting steel re-inforcement against corrosion mixed @ 1% by weight of cementitious content in concrete. ie., integral crystaline waterproofing admix @ 0.5 kg/bag of cement. (For calculation purpose 320 kg of Cement for M-20 grade of Concrete is considered in the analysis)
| Sqm | 761.99 | 761.99 | 196.73 | False | None | None | False | None | False | 149906.2927 | 0 | 3261934 | 113003 | None | V-2 P.No 60 It.No 9.11 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thick- ness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete.
| Sqm | 1101.47 | 1101.47 | 117.92 | False | None | None | False | None | False | 129885.3424 | 0 | 3261935 | 113003 | None | V-2 P.No 65 It.No 9.39 | Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications.
| Sqm | 1795.31 | 1795.31 | 601.92 | False | None | None | False | None | False | 1080632.9952 | 0 | 3261936 | 113003 | None | V-2 P.No 85 It.No 11.28 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.
| Kg | 700.04 | 700.04 | 1455.3 | False | None | None | False | None | False | 1018768.212 | 0 | 3261937 | 113003 | None | V-2 P.No 48 It.No 8.39 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 157.35 | 157.35 | 15157.08 | False | None | None | False | None | False | 2384966.538 | 0 | 3261938 | 113003 | None | V-2 P.No 46 It.No 8.32 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 g/L and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 L/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 193.28 | 193.28 | 752.87 | False | None | None | False | None | False | 145514.7136 | 0 | 3261939 | 113003 | None | V-2 P.No 47 It.No 8.34.3 | Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 61.95 | 61.95 | 307.17 | False | None | None | False | None | False | 19029.1815 | 0 | 3261940 | 113003 | None | V-2 P.No 48 It.No 8.40 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 142.49 | 142.49 | 307.17 | False | None | None | False | None | False | 43768.6533 | 0 | 3261941 | 113003 | None | V-2 P.No 47 It.No 8.34.1 | Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 65.67 | 65.67 | 540.0 | False | None | None | False | None | False | 35461.8 | 0 | 3261942 | 113003 | None | V-2 P.No 54 It.No 8.82 | Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below:
1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 no.
2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs.
3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs.4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. (Final coat to be done in 1 or 2 layers without gap of time.)"
| Sqm | 838.8 | 838.8 | 540.0 | False | None | None | False | None | False | 452952.0 | 0 | 3261943 | 113003 | None | V-2 P.No 181 It.no 18.1 | Providing and supplying aluminium extruded tubular and other alu- minium sections as per the architectural drawings and approved draw- ings of Chief Architect, GoK.The aluminium quality shall be as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. ( The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account).The weight of aluminium extruded section shall be taken for purpose of payment.
| Kg | 504.27 | 504.27 | 2730.0 | False | None | None | False | None | False | 1376657.1 | 0 | 3261944 | 113003 | None | V-2page183itm18.3 | Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface 2 of approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge. The IGUs shall be assembled in the factory/ workshop of the glass processor. (Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.18.2)For payment, only the actual area of glass on face 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in m2.(i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face 2, 12mm Airgap 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 Light reflection internal 10 to 15%, light reflection external 10 to 20shading coefficient (0.25-0.28) and U value of 3.0 to 3.3 W/ m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement.
| Sqm | 3770.28 | 3770.28 | 300.0 | False | None | None | False | None | False | 1131084.0 | 0 | 3261945 | 113003 | None | V-2page183itm18.4 | Extra for openable side / top hung vision glass panels (IGUs) including providing and supplying at site all accessories and hardwares for the openable panels as specified and of the approved make such as heavy duty stainless steel friction hinges, min 4 -point cremone locking sets with stainless steel plates, handles, buffers etc. including necessary stainless steel screws/ fasteners, nuts, bolts, washers etc. all complete as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer- in-Charge.
| Sqm | 5151.76 | 5151.76 | 120.0 | False | None | None | False | None | False | 618211.2 | 0 | 3261946 | 113003 | None | V-2 P.No 24 It.No 7.28.1 | Providing & fixing 10 mm thick plaster of Paris (gypsum anhydrous) ceiling up to a height of 5 m above floor level, over first class kail wood strips 25x6 mm with 10 mm gap in between and reinforced with rabbit wire mesh fixed to wooden frame. Flat surfaces
| Sqm | 1578.49 | 1578.49 | 434.1 | False | None | None | False | None | False | 685222.509 | 0 | 3261947 | 113003 | None | V-2 P.No 28 It.No 7.41 | Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per m2 including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross “T” of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main’T’ at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross ‘T’ of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel of size(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230 mm interval and laying 15 mm thick densified edges calicum silicate ceiling tiles of approved texture in the grid, including, cutting/ making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required. Main ‘T’ runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main ‘T’, bottom exposed with 24 mm of all T sections shall be pre-painted with polyster baked paint, for all heights, as per specifications, drawings and as directed by Engineer-in-Charge.
| Sqm | 2097.63 | 2097.63 | 651.1 | False | None | None | False | None | False | 1365766.893 | 0 | 3261948 | 113003 | None | V-2page111itm12.92 | Providing& fixing of Openable door made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPV(Thermo Plastic Vulcanized) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the openable frame. The frame having overall size of 60mm 55mm with GI reinforcement of 1mm thickness and openable sash with overall size of 60mm 102mm and GI reinforcement of 2mm thickness. Coextruded Glazing bead for fixing of glass shall be of size 20mm 34 mm. Windows shall be provided with 6mm plain float glass, Standard hardware with 2D/3D hinge & Multi point locking system with Handle. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 900mm 2400mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)
| Sqm | 7737.56 | 7737.56 | 36.0 | False | None | None | False | None | False | 278552.16 | 0 | 3261949 | 113003 | None | V-1 (CPWD)p205itm9.137 | Providing and fixing 50 mm thick glazed fire resistant door shutters of 60 minutes fire rating conforming to IS:3614 (Part-II), tested and certified as per laboratory approved by Engineer-in-charge, with suitable mounting on door frame, consisting of vertical styles, lock rail, top rail 100 mm wide, bottom rail 200 mm wide, made out of 16 SWG G.I.sheet (zinc coating not less than 120 gm/m2) duly filled FR insulation material and fixing with necessary stainless steel ball bearing hinges of approved make, including applying a coat of approved fire resistant primer etc. all complete as per direction of Engineer-in-charge (panneling to be paid for separately). | Sqm | 6444.95 | 6444.95 | 144.0 | False | None | None | False | None | False | 928072.8 | 0 | 3261950 | 113003 | None | V-1 (CPWD)p205itm9.136 | Providing and fixing fire resistant door frame of section 143 x 57 mm having built in rebate made out of 16 SWG G.I. sheet (zinc coating not less than 120 gm/sqm) duly filled with vermuculite based concrete mix, suitable for mounting 60 minutes fire rated door shutters. The frame is fitted with intumuscent fire seal strip of size 10x4 mm (minimum) alround the frame and fixing with dash fastener of approved size and make, including applying a coat of approved brand fire resistant primer etc. complete as per direction of Engineer-in-charge (Dash fastener to bepaid for separately). | m | 1462.75 | 1462.75 | 451.2 | False | None | None | False | None | False | 659992.8 | 0 | 3261951 | 113003 | None | V-1 (CPWD)P132ITM5.44.1 | Providing and fixing of expansion joint system related with floor location as per drawings and direction of Engineer-In-Charge. The joints system will be of extruded aluminum base members, self aligning / self centering arrangement and support plates etc. as per ASTM B221-02. The system shall be such that it provides floor to floor /floor to wall expansion control system for various vertical localtion in load application areas that accommodates multi directional seismic movement without stress to it's components. System shall consist of metal profiles with a universalaluminum base member designed to accommodate various project conditions and finish floor treatments. The cover plate shall be designed of width and thickness required to satisfy projects movement and loading requirements and secured to base members by utilizing manufacturer’s pre-engineered self- centering arrangement that freely rotates / moves in all directions. The Self - centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum
extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. Provision of Moisture Barrier Membrane in the Joint System to have watertight joint is mandatory requirement all as per the manufactures design and as approved by Engineer -in Charge. (Material shall confirm to ASTM 6063). Floor Joint of 100 mm gap
| m | 5800.15 | 5800.15 | 420.0 | False | None | None | False | None | False | 2436063.0 | 0 | 3261952 | 113003 | None | V-1 (CPWD)P132ITM5.45.1 | Providing and fixing of expansion joint system related with wall joint (internal/external) location as per drawings and direction of Engineer-InCharge. The joints shall be of extruded aluminum base members, self aligning / centering arrangement and support plates as per ASTM B221- 02. The material shall be such that it provides an Expansion Joints System suitable for vertical wall to wall/ wall to corner application, both new and existing construction in office Buildings & complexes with no slipping down tendency amongst the components of the Joint System. The Joint System shall utilize light weight aluminum profiles exhibiting minimal exposed aluminum surfaces mechanically snap locking the multicellular to facilitate movement. (Material shall confirm to ASTM 6063) Wall Joint of 100 mm gap | m | 4835.5 | 4835.5 | 420.0 | False | None | None | False | None | False | 2030910.0 | 0 | 3261953 | 113003 | None | V-1 (CPWD)P132ITM5.46.1 | Providing and fixing of expansion joint system of approved make and manufactures for various roof locations as per approved drawings and direction of Engineer-In-Charge. The joints shall be of extruded aluminum base members with, self aligning and self centering arragement support plates asper ASTM B221-02. The system shall be such that it provides watertight roof to roof/roof to corner joint cover expansion control system that is capable of accommodating multidirectional seismic movement without stress to its components. System shall consist of metal profile that incorporates a universal aluminum base member designed toaccommodate various project conditions and roof treatments. The cover plate shall be designed of width and thickness required to satisfy movement and loading requirements and secured to base members by utilizing manufacturer’s pre-engineered self-centering arrangement that freely rotates / moves in all directions. The Self centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. The Joint
System shall resists damage or deterioration from the impact of falling ice, exposure to UV, airborne contaminants and occasional foot traffic from maintenance personnel. Provision of Moisture Barrier Membrane in the Joint System to have water tight joint is mandatory requirement. (Material shall confirm to ASTM 6063). Roof Joint of 100 mm gap"
| m | 5454.2 | 5454.2 | 735.0 | False | None | None | False | None | False | 4008837.0 | 0 | 3261954 | 113003 | None | APPROVED RATE | Providing and laying Basant beton Paving tiles 40mm thick interlock pavers, using cement and course sand for manufacture of paving tile of approved size, shape and colour over 50mm thick cement mortar (average thickness ) and compacting with plate vibrator having 3 tons compaction force thereby forcing part of sand underneath to come up in between joints, final compaction of paver surface joints into its final level, including cost of materials, labour and HOM of machineries complete as per specifications. complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work. GROUND FLOOR
| Sqm | 3872.76 | 3872.76 | 184.02 | False | None | None | False | None | False | 712665.2952 | 0 | 3261955 | 113003 | None | DATA RATE | Providing and fixing aluminium coated and polyester based netted curtains complete. The work includes cost of all materials, labour charges, lead and lift, etc., complete.
| Rmtr | 2596.0 | 2596.0 | 150.0 | False | None | None | False | None | False | 389400.0 | 0 | 3261956 | 113003 | None | V-1PAGE15itm2.2.5 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, The cost includes Form work, lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
| Cum | 8052.26 | 8052.26 | 527.5 | False | None | None | False | None | False | 4247567.15 | 0 | 3261957 | 113003 | None | V-2P45ITM8.29 | Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 L/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 350.64 | 350.64 | 501.91 | False | None | None | False | None | False | 175989.7224 | 0 | 3261958 | 113003 | None | V-2page94itm11.52 | Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and stopper etc. to be paid separately) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.
| Sqm | 5850.56 | 5850.56 | 21.6 | False | None | None | False | None | False | 126372.096 | 0 | 3261959 | 113003 | None | V-2page64itm9.30 | Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints fin- ished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications.
| Sqm | 6601.39 | 6601.39 | 327.49 | False | None | None | False | None | False | 2161889.2111 | 0 | 3261960 | 113003 | None | V-2page67itm9.24 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.
Polished Granite stone slab Black, Cat Eye, River Pink or equivalent
| Sqm | 3533.63 | 3533.63 | 184.67 | False | None | None | False | None | False | 652555.4521 | 0 |
| 1718022464000 | 0 | None | None | Buildings | FIRST FLOOR(CIVIL WORKS) | 105204331.99 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3261961 | 113004 | None | V-1 P.No 17 It.No 2.5.5 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes Form work, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars to be paid separately) M40 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(COLUMNS & LIFTS CORE WALLS)
| Cum | 16002.02 | 16002.02 | 533.15 | False | None | None | False | None | False | 8531476.963 | 0 | 3261962 | 113004 | None | V-1 P.No 17 It.No 2.5.5 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes Form work, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars to be paid separately) M40 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(RCC BEAMS) | Cum | 15060.73 | 15060.73 | 472.91 | False | None | None | False | None | False | 7122369.8243 | 0 | 3261963 | 113004 | None | V-1 P.No 16 It.No 2.5.2 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork RCC SLAB
| Cum | 14119.43 | 14119.43 | 621.33 | False | None | None | False | None | False | 8772825.4419 | 0 | 3261964 | 113004 | None | V-1 P.No 17 It.No 2.5.5 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes Form work, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars to be paid separately) M40 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
(RCC STAIRCASE)
| Cum | 14119.43 | 14119.43 | 37.11 | False | None | None | False | None | False | 523972.0473 | 0 | 3261965 | 113004 | None | V-1 P.No 17 It.No 2.5.5 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes Form work, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars to be paid separately) M40 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(LINTELS)
| Cum | 15060.73 | 15060.73 | 19.98 | False | None | None | False | None | False | 300913.3854 | 0 | 3261966 | 113004 | None | V-1 P.No 16 It.No 2.5.1 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork
| Cum | 12030.24 | 12030.24 | 25.93 | False | None | None | False | None | False | 311944.1232 | 0 | 3261967 | 113004 | None | V-1 P.No 18 It.No 2.11 a | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.
| Tonne | 111945.6 | 111945.6 | 253.7 | False | None | None | False | None | False | 28400598.72 | 0 | 3261968 | 113004 | None | 18-19 SR P.No 15 It.No 4.21 | Extra for providing throating or drip moulding to RCC chejjas with plastering ( labour charges only ) as per specifications. Specification No . KBS
| Rmtr | 38.94 | 38.94 | 613.3 | False | None | None | False | None | False | 23881.902 | 0 | 3261969 | 113004 | None | V-2 P.No 17 It.No 6.32 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.
| Sqm | 1639.32 | 1639.32 | 4626.73 | False | None | None | False | None | False | 7584691.0236 | 0 | 3261970 | 113004 | None | V-2 P.No 17 It.No 6.34 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.
| Sqm | 1381.53 | 1381.53 | 989.09 | False | None | None | False | None | False | 1366457.5077 | 0 | 3261971 | 113004 | None | V-2 P.No 105 It.No 12.57.6 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification.-do- 35 mm thick both side Commercial
| Sqm | 4157.12 | 4157.12 | 221.04 | False | None | None | False | None | False | 918889.8048 | 0 | 3261972 | 113004 | None | V-2 P.No 100 It.No 12.13.1 | Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. | Cum | 123656.1 | 123656.1 | 7.91 | False | None | None | False | None | False | 978119.751 | 0 | 3261973 | 113004 | None | V-2 P.No 105 It.No 12.51 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications.
| No | 1271.41 | 1271.41 | 81.0 | False | None | None | False | None | False | 102984.21 | 0 | 3261974 | 113004 | None | V-2 P.No 218 It.No 22.15.2 | Providing and fixing Stainless Steel Fixtures conforming to 304
graded steel as per direction of engineer in charge.SS Handles 300mm
| No | 688.26 | 688.26 | 162.0 | False | None | None | False | None | False | 111498.12 | 0 | 3261975 | 113004 | None | V-2 P.No 219 It.No 22.15.4 | Providing and fixing Stainless Steel Fixtures conforming to 304
graded steel as per direction of engineer in charge.SS Aldrop 16mm dia, 300mm
| No | 469.27 | 469.27 | 81.0 | False | None | None | False | None | False | 38010.87 | 0 | 3261976 | 113004 | None | V-2 P.No 219 It.No 22.15.6 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Tower Bolts 200x10mm
| No | 187.71 | 187.71 | 162.0 | False | None | None | False | None | False | 30409.02 | 0 | 3261977 | 113004 | None | V-2 P.No 219 It.No 22.15.9 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS hinges 100 mm
| No | 87.6 | 87.6 | 324.0 | False | None | None | False | None | False | 28382.4 | 0 | 3261978 | 113004 | None | V-2 P.No 219 It.No 22.15.10 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Door stopper 75mm
| No | 125.14 | 125.14 | 81.0 | False | None | None | False | None | False | 10136.34 | 0 | 3261979 | 113004 | None | V-2 P.No 105 It.No 12.60 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.
| No | 1316.46 | 1316.46 | 81.0 | False | None | None | False | None | False | 106633.26 | 0 | 3261980 | 113004 | None | V-2 P.No 69 It.No 10.6.3 | Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm
| No | 75.08 | 75.08 | 486.0 | False | None | None | False | None | False | 36488.88 | 0 | 3261981 | 113004 | None | V-2p205itm20.79 | Supplying and fixing new teak wood beads wherever necessary including cost of materials, labour, complete as per specifications. | Rmtr | 65.07 | 65.07 | 489.9 | False | None | None | False | None | False | 31877.793 | 0 | 3261982 | 113004 | None | V-2 P.No 110 It.No 12.90 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall
be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)
| Sqm | 8426.86 | 8426.86 | 250.2 | False | None | None | False | None | False | 2108400.372 | 0 | 3261983 | 113004 | None | V-2 P.No 109 It.No 12.85 | Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)
| Sqm | 7156.7 | 7156.7 | 64.62 | False | None | None | False | None | False | 462465.954 | 0 | 3261984 | 113004 | None | V-2 P.No 86 It.No 11.34A | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding
| Kg | 210.23 | 210.23 | 6611.22 | False | None | None | False | None | False | 1389876.7806 | 0 | 3261985 | 113004 | None | V-2 P.No 111 It.No 12.93.1 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately)Size 62 x 100mm
| Rmtr | 878.48 | 878.48 | 234.0 | False | None | None | False | None | False | 205564.32 | 0 | 3261986 | 113004 | None | V-2 P.No 112 It.No 12.94.1 | Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately)30 mm thickness
| Sqm | 4361.09 | 4361.09 | 74.52 | False | None | None | False | None | False | 324988.4268 | 0 | 3261987 | 113004 | None | V-2 P.No 107 It.No 12.59 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete.
| No | 1394.05 | 1394.05 | 91.0 | False | None | None | False | None | False | 126858.55 | 0 | 3261988 | 113004 | None | V-2 P.No 41 It.No 8.4.2 | Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( Inside)
| Sqm | 390.43 | 390.43 | 7031.93 | False | None | None | False | None | False | 2745476.4299 | 0 | 3261989 | 113004 | None | V-2 P.No 43 It.No 8.10 | Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 264.04 | 264.04 | 6607.02 | False | None | None | False | None | False | 1744517.5608 | 0 | 3261990 | 113004 | None | V-2 P.No 50 It.No 8.51 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.
| Sqm | 125.14 | 125.14 | 13639.0 | False | None | None | False | None | False | 1706784.46 | 0 | 3261991 | 113004 | None | V-2 P.No 42 It.No 8.5.2 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( Outside)
| Sqm | 436.74 | 436.74 | 1656.18 | False | None | None | False | None | False | 723320.0532 | 0 | 3261992 | 113004 | None | V-2 P.No 41 It.No 8.3.1 | Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per direc- tions of Engineer-in-charge.
| Sqm | 442.99 | 442.99 | 206.59 | False | None | None | False | None | False | 91517.3041 | 0 | 3261993 | 113004 | None | V-2 P.No 43 It.No 8.16.2 | Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment.Plaster mesh 150mm wide
| Rmtr | 47.55 | 47.55 | 4200.0 | False | None | None | False | None | False | 199710.0 | 0 | 3261994 | 113004 | None | 18-19 SR69ITM10.5.2 | Bore Packing : Filling the bore wherever necessary with polymer modified concrete and brushing one coat of acrylic copolymer cross linked formulaion on the bore. Including all labour charges tools and equipments, all complete as per the manufacturer.
| Sqm | 283.2 | 283.2 | 50.0 | False | None | None | False | None | False | 14160.0 | 0 | 3261995 | 113004 | None | V-2 P.No 54 It.no 8.79 | Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove.
| Rmtr | 65.07 | 65.07 | 1568.8 | False | None | None | False | None | False | 102081.816 | 0 | 3261996 | 113004 | None | V-2 P.No 61 It.No 9.17.2 | Providing and laying Vitrified tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600x600 mm
| Sqm | 1470.38 | 1470.38 | 3778.67 | False | None | None | False | None | False | 5556080.7946 | 0 | 3261997 | 113004 | None | V-2 P.No 62 It.No 9.22.2 | Providing and laying Polished Glazed Vitrified tiles with thickness 10 mm in floor with different sizes with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).Size of Tile 600x600 mm
| Sqm | 1659.34 | 1659.34 | 2760.16 | False | None | None | False | None | False | 4580043.8944 | 0 | 3261998 | 113004 | None | V-2 P.No 63 It.No 9.24 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.
** Polished Granite stone slab Black, Cat Eye, River Pink or equivalent.
| Sqm | 3568.96 | 3568.96 | 430.26 | False | None | None | False | None | False | 1535580.7296 | 0 | 3261999 | 113004 | None | V-2P64itm9.30 | Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints fin- ished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications.
| Sqm | 6667.41 | 6667.41 | 327.49 | False | None | None | False | None | False | 2183510.1009 | 0 | 3262000 | 113004 | None | V-2 P.No 41 It.No 8.2.1 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 369.16 | 369.16 | 3539.33 | False | None | None | False | None | False | 1306579.0628 | 0 | 3262001 | 113004 | None | V-2 P.No 23 It.No 7.18 | Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications.
| Cum | 2524.05 | 2524.05 | 55.13 | False | None | None | False | None | False | 139150.8765 | 0 | 3262002 | 113004 | None | V-2 P.No 150 It.No 15.7 | Providing and supplying crystalline integral concrete waterproofing admixture that waterproofs concrete by forming crystals deep in the pores, capillaries and microcracks of the concrete, self-seal waterproofing compound to bridge shrinkage cracks upto 0.5mm in width & resist hydro-static pressure upto 16bar for both positive & negative pressure confirming to DIN 1048 part 5 for 56% reduction in depth of penetration against control, resistance to chloride penetration confirming to ASTM C 1202 with 64% improvement against control & protecting steel re-inforcement against corrosion mixed @ 1% by weight of cementitious content in concrete. ie., integral crystaline waterproofing admix @ 0.5 kg/bag of cement. (For calculation purpose 320 kg of Cement for M-20 grade of Concrete is considered in the analysis)
| Sqm | 769.6 | 769.6 | 290.13 | False | None | None | False | None | False | 223284.048 | 0 | 3262003 | 113004 | None | V-2 P.No 60 It.No 9.11 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thick- ness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete.
| Sqm | 1112.49 | 1112.49 | 183.76 | False | None | None | False | None | False | 204431.1624 | 0 | 3262004 | 113004 | None | V-2 P.No 65 It.No 9.39 | Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications.
| Sqm | 1813.26 | 1813.26 | 779.17 | False | None | None | False | None | False | 1412837.7942 | 0 | 3262005 | 113004 | None | V-2 P.No 85 It.No 11.28 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.
| Kg | 707.04 | 707.04 | 1293.6 | False | None | None | False | None | False | 914626.944 | 0 | 3262006 | 113004 | None | V-2 P.No 48 It.No 8.39 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 158.93 | 158.93 | 13638.95 | False | None | None | False | None | False | 2167638.3235 | 0 | 3262007 | 113004 | None | V-2 P.No 46 It.No 8.32 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 g/L and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 L/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 195.22 | 195.22 | 993.71 | False | None | None | False | None | False | 193992.0662 | 0 | 3262008 | 113004 | None | V-2 P.No 47 It.No 8.34.3 | Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 62.57 | 62.57 | 314.82 | False | None | None | False | None | False | 19698.2874 | 0 | 3262009 | 113004 | None | V-2 P.No 48 It.No 8.40 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 143.91 | 143.91 | 314.82 | False | None | None | False | None | False | 45305.7462 | 0 | 3262010 | 113004 | None | V-2 P.No 47 It.No 8.34.1 | Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 66.32 | 66.32 | 530.5 | False | None | None | False | None | False | 35182.76 | 0 | 3262011 | 113004 | None | V-2 P.No 54 It.No 8.82 | Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below:
1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 no.
2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs.
3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs.4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. (Final coat to be done in 1 or 2 layers without gap of time.) | Sqm | 847.19 | 847.19 | 530.5 | False | None | None | False | None | False | 449434.295 | 0 | 3262012 | 113004 | None | V-2 P.No 181 It.No 18.1 | Providing and supplying aluminium extruded tubular and other alu- minium sections as per the architectural drawings and approved draw- ings of Chief Architect, GoK.The aluminium quality shall be as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. ( The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account).The weight of aluminium extruded section shall be taken for purpose of payment.
| Kg | 509.32 | 509.32 | 2632.5 | False | None | None | False | None | False | 1340784.9 | 0 | 3262013 | 113004 | None | V-2page183itm18.3 | Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface 2 of approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge. The IGUs shall be assembled in the factory/ workshop of the glass processor. (Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.18.2)For payment, only the actual area of glass on face 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in m2.(i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face 2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 , Light reflection internal 10 to 15 light reflection external 10 to 20 ,shading coefficient (0.25-0.28) and U value of 3.0 to 3.3 W/ m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement.
| Sqm | 3807.98 | 3807.98 | 300.0 | False | None | None | False | None | False | 1142394.0 | 0 | 3262014 | 113004 | None | V-2page183itm18.4 | Extra for openable side / top hung vision glass panels (IGUs) including providing and supplying at site all accessories and hardwares for the openable panels as specified and of the approved make such as heavy duty stainless steel friction hinges, min 4 -point cremone locking sets with stainless steel plates, handles, buffers etc. including necessary stainless steel screws/ fasteners, nuts, bolts, washers etc. all complete as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer- in-Charge.
| Sqm | 5203.28 | 5203.28 | 120.0 | False | None | None | False | None | False | 624393.6 | 0 | 3262015 | 113004 | None | V-2 P.No 24 It.No 7.28.1 | Providing & fixing 10 mm thick plaster of Paris (gypsum anhydrous) ceiling up to a height of 5 m above floor level, over first class kail wood strips 25x6 mm with 10 mm gap in between and reinforced with rabbit wire mesh fixed to wooden frame. Flat surfaces
| Sqm | 1594.27 | 1594.27 | 617.3 | False | None | None | False | None | False | 984142.871 | 0 | 3262016 | 113004 | None | V-2 P.No 28 It.No 7.41 | Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per m2 including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross “T” of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main’T’ at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross ‘T’ of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel of size(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230 mm interval and laying 15 mm thick densified edges calicum silicate ceiling tiles of approved texture in the grid, including, cutting/ making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required. Main ‘T’ runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main ‘T’, bottom exposed with 24 mm of all T sections shall be pre-painted with polyster baked paint, for all heights, as per specifications, drawings and as directed by Engineer-in-Charge.
| Sqm | 2118.6 | 2118.6 | 925.9 | False | None | None | False | None | False | 1961611.74 | 0 | 3262017 | 113004 | None | V-2p45itm8.29 | Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 L/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 354.14 | 354.14 | 662.47 | False | None | None | False | None | False | 234607.1258 | 0 | 3262018 | 113004 | None | V-2page111itm12.92 | Providing& fixing of Openable door made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPV(Thermo Plastic Vulcanized) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the openable frame. The frame having overall size of 60mm55mm with GI reinforcement of 1mm thickness and openable sash with overall size of 60mm 102mm and GI reinforcement of 2mm thickness. Coextruded Glazing bead for fixing of glass shall be of size 20mm 34 mm. Windows shall be provided with 6mm plain float glass, Standard hardware with 2D/3D hinge & Multi point locking system with Handle. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 900mm 2400mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)
| Sqm | 7814.93 | 7814.93 | 36.0 | False | None | None | False | None | False | 281337.48 | 0 | 3262019 | 113004 | None | data rate | Providing and fixing aluminium coated and polyester based netted curtains complete. The work includes cost of all materials, labour charges, lead and lift, etc., complete.
| Rmtr | 2596.0 | 2596.0 | 150.0 | False | None | None | False | None | False | 389400.0 | 0 |
| 1718022464000 | 0 | None | None | Buildings | SECOND FLOOR(CIVIL WORKS) | 97091990.54 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3262020 | 113005 | None | V-1 P.No 17 It.No 2.5.5 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes Form work, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars to be paid separately) M40 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
| Cum | 16160.46 | 16160.46 | 505.55 | False | None | None | False | None | False | 8169920.553 | 0 | 3262021 | 113005 | None | V-1 P.No 17 It.No 2.5.5 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes Form work, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars to be paid separately) M40 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
| Cum | 15209.85 | 15209.85 | 464.59 | False | None | None | False | None | False | 7066344.2115 | 0 | 3262022 | 113005 | None | V-1 P.No 17 It.No 2.5.5 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes Form work, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars to be paid separately) M40 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
(RCC SLAB) | Cum | 14259.23 | 14259.23 | 567.13 | False | None | None | False | None | False | 8086837.1099 | 0 | 3262023 | 113005 | None | V-1 P.No 17 It.No 2.5.5 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes Form work, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars to be paid separately) M40 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
| Cum | 14259.23 | 14259.23 | 37.11 | False | None | None | False | None | False | 529160.0253 | 0 | 3262024 | 113005 | None | V-1 P.No 17 It.No 2.5.5 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes Form work, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars to be paid separately) M40 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(LINTELS)
| Cum | 15209.85 | 15209.85 | 21.4 | False | None | None | False | None | False | 325490.79 | 0 | 3262025 | 113005 | None | V-1 P.No 16 It.No 2.5.1 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork
| Cum | 12149.35 | 12149.35 | 29.63 | False | None | None | False | None | False | 359985.2405 | 0 | 3262026 | 113005 | None | V-1 P.No 18 It.No 2.11 a | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.
| Tonne | 113053.97 | 113053.97 | 229.24 | False | None | None | False | None | False | 25916492.0828 | 0 | 3262027 | 113005 | None | 18-19 SR P.No 15 It.No 4.21 | Extra for providing throating or drip moulding to RCC chejjas with plastering ( labour charges only ) as per specifications. Specification No . KBS
| Rmtr | 38.94 | 38.94 | 659.9 | False | None | None | False | None | False | 25696.506 | 0 | 3262028 | 113005 | None | V-2 P.No 17 It.No 6.32 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.
| Sqm | 1655.55 | 1655.55 | 4353.11 | False | None | None | False | None | False | 7206791.2605 | 0 | 3262029 | 113005 | None | V-2 P.No 17 It.No 6.34 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.
| Sqm | 1395.21 | 1395.21 | 985.22 | False | None | None | False | None | False | 1374588.7962 | 0 | 3262030 | 113005 | None | V-2 P.No 106 It.No 12.57.6 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 35 mm thick both side commercial
| Sqm | 4198.28 | 4198.28 | 205.56 | False | None | None | False | None | False | 862998.4368 | 0 | 3262031 | 113005 | None | V-2 P.No 100 It.No 12.13.1 | Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. | Cum | 124880.42 | 124880.42 | 6.9 | False | None | None | False | None | False | 861674.898 | 0 | 3262032 | 113005 | None | V-2 P.No 105 It.No 12.51 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications.
| No | 1284.0 | 1284.0 | 81.0 | False | None | None | False | None | False | 104004.0 | 0 | 3262033 | 113005 | None | V-2 P.No 218 It.No 22.15.2 | Providing and fixing Stainless Steel Fixtures conforming to 304
graded steel as per direction of engineer in charge.SS Handles 300mm
| No | 695.08 | 695.08 | 162.0 | False | None | None | False | None | False | 112602.96 | 0 | 3262034 | 113005 | None | V-2 P.No 219 It.No 22.15.4 | Providing and fixing Stainless Steel Fixtures conforming to 304
graded steel as per direction of engineer in charge.SS Aldrop 16mm dia, 300mm
| No | 473.92 | 473.92 | 81.0 | False | None | None | False | None | False | 38387.52 | 0 | 3262035 | 113005 | None | V-2 P.No 219 It.No 22.15.6 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Tower Bolts 200x10mm
| No | 189.57 | 189.57 | 162.0 | False | None | None | False | None | False | 30710.34 | 0 | 3262036 | 113005 | None | V-2 P.No 219 It.No 22.15.9 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS hinges 100 mm
| No | 88.46 | 88.46 | 324.0 | False | None | None | False | None | False | 28661.04 | 0 | 3262037 | 113005 | None | V-2 P.No 219 It.No 22.15.10 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Door stopper 75mm
| No | 126.38 | 126.38 | 81.0 | False | None | None | False | None | False | 10236.78 | 0 | 3262038 | 113005 | None | V-2 P.No 105 It.No 12.60 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.
| No | 1329.5 | 1329.5 | 81.0 | False | None | None | False | None | False | 107689.5 | 0 | 3262039 | 113005 | None | V-2 P.No 69 It.No 10.6.3 | Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm
| No | 75.83 | 75.83 | 486.0 | False | None | None | False | None | False | 36853.38 | 0 | 3262040 | 113005 | None | V-2p205itm20.79 | Supplying and fixing new teak wood beads wherever necessary including cost of materials, labour, complete as per specifications. | Rmtr | 65.72 | 65.72 | 474.45 | False | None | None | False | None | False | 31180.854 | 0 | 3262041 | 113005 | None | V-2 P.No 110 It.No 12.90 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall
be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)
| Sqm | 8510.29 | 8510.29 | 302.85 | False | None | None | False | None | False | 2577341.3265 | 0 | 3262042 | 113005 | None | V-2 P.No 109 It.No 12.85 | Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)
| Sqm | 7227.56 | 7227.56 | 68.76 | False | None | None | False | None | False | 496967.0256 | 0 | 3262043 | 113005 | None | V-2 P.No 86 It.No 11.34A | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding
| Kg | 212.32 | 212.32 | 7803.81 | False | None | None | False | None | False | 1656904.9392 | 0 | 3262044 | 113005 | None | V-2 P.No 111 It.No 12.93.1 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately)Size 62 x 100mm
| Rmtr | 887.17 | 887.17 | 174.0 | False | None | None | False | None | False | 154367.58 | 0 | 3262045 | 113005 | None | V-2 P.No 112 It.No 12.94.1 | Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately)30 mm thickness
| Sqm | 4404.27 | 4404.27 | 54.81 | False | None | None | False | None | False | 241398.0387 | 0 | 3262046 | 113005 | None | V-2 P.No 107 It.No 12.59 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete.
| No | 1407.85 | 1407.85 | 91.0 | False | None | None | False | None | False | 128114.35 | 0 | 3262047 | 113005 | None | V-2 P.No 41 It.No 8.4.2 | Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( Inside)
| Sqm | 394.3 | 394.3 | 5217.77 | False | None | None | False | None | False | 2057366.711 | 0 | 3262048 | 113005 | None | V-2 P.No 43 It.No 8.10 | Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 266.66 | 266.66 | 6535.86 | False | None | None | False | None | False | 1742852.4276 | 0 | 3262049 | 113005 | None | V-2 P.No 50 It.No 8.51 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.
| Sqm | 126.38 | 126.38 | 11753.6 | False | None | None | False | None | False | 1485419.968 | 0 | 3262050 | 113005 | None | V-2 P.No 42 It.No 8.5.2 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( Outside)
| Sqm | 441.06 | 441.06 | 1396.35 | False | None | None | False | None | False | 615874.131 | 0 | 3262051 | 113005 | None | V-2 P.No 41 It.No 8.3.1 | Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per direc- tions of Engineer-in-charge.
| Sqm | 447.38 | 447.38 | 206.59 | False | None | None | False | None | False | 92424.2342 | 0 | 3262052 | 113005 | None | V-2 P.No 43 It.No 8.16.2 | Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment.Plaster mesh 150mm wide
| Rmtr | 48.02 | 48.02 | 4200.0 | False | None | None | False | None | False | 201684.0 | 0 | 3262053 | 113005 | None | 18-19 SR69ITM10.5.2 | Bore Packing : Filling the bore wherever necessary with polymer modified concrete and brushing one coat of acrylic copolymer cross linked formulaion on the bore. Including all labour charges tools and equipments, all complete as per the manufacturer.
| Sqm | 283.2 | 283.2 | 50.0 | False | None | None | False | None | False | 14160.0 | 0 | 3262054 | 113005 | None | V-2 P.No 54 It.no 8.79 | Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove.
| Rmtr | 65.72 | 65.72 | 1550.8 | False | None | None | False | None | False | 101918.576 | 0 | 3262055 | 113005 | None | V-2 P.No 61 It.No 9.17.2 | Providing and laying Vitrified tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600x600 mm
| Sqm | 1484.94 | 1484.94 | 3098.97 | False | None | None | False | None | False | 4601784.5118 | 0 | 3262056 | 113005 | None | V-2 P.No 62 It.No 9.22.2 | Providing and laying Polished Glazed Vitrified tiles with thickness 10 mm in floor with different sizes with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).Size of Tile 600x600 mm
| Sqm | 1675.77 | 1675.77 | 2197.4 | False | None | None | False | None | False | 3682336.998 | 0 | 3262057 | 113005 | None | V-2 P.No 63 It.No 9.24 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.
** Polished Granite stone slab Black, Cat Eye, River Pink or equivalent.
| Sqm | 3604.3 | 3604.3 | 216.31 | False | None | None | False | None | False | 779646.133 | 0 | 3262058 | 113005 | None | V-2P64itm9.30 | Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints fin- ished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications.
| Sqm | 6733.42 | 6733.42 | 327.49 | False | None | None | False | None | False | 2205127.7158 | 0 | 3262059 | 113005 | None | V-2 P.No 41 It.No 8.2.1 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 372.82 | 372.82 | 2936.8 | False | None | None | False | None | False | 1094897.776 | 0 | 3262060 | 113005 | None | V-2 P.No 23 It.No 7.18 | Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications.
| Cum | 2549.04 | 2549.04 | 51.7 | False | None | None | False | None | False | 131785.368 | 0 | 3262061 | 113005 | None | V-2 P.No 150 It.No 15.7 | Providing and supplying crystalline integral concrete waterproofing admixture that waterproofs concrete by forming crystals deep in the pores, capillaries and microcracks of the concrete, self-seal waterproofing compound to bridge shrinkage cracks upto 0.5mm in width & resist hydro-static pressure upto 16bar for both positive & negative pressure confirming to DIN 1048 part 5 for 56% reduction in depth of penetration against control, resistance to chloride penetration confirming to ASTM C 1202 with 64% improvement against control & protecting steel re-inforcement against corrosion mixed @ 1% by weight of cementitious content in concrete. ie., integral crystaline waterproofing admix @ 0.5 kg/bag of cement. (For calculation purpose 320 kg of Cement for M-20 grade of Concrete is considered in the analysis)
| Sqm | 777.22 | 777.22 | 271.62 | False | None | None | False | None | False | 211108.4964 | 0 | 3262062 | 113005 | None | V-2 P.No 60 It.No 9.11 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thick- ness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete.
| Sqm | 1123.5 | 1123.5 | 172.34 | False | None | None | False | None | False | 193623.99 | 0 | 3262063 | 113005 | None | V-2 P.No 65 It.No 9.39 | Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications.
| Sqm | 1831.22 | 1831.22 | 739.4 | False | None | None | False | None | False | 1354004.068 | 0 | 3262064 | 113005 | None | V-2 P.No 85 It.No 11.28 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.
| Kg | 714.04 | 714.04 | 1293.6 | False | None | None | False | None | False | 923682.144 | 0 | 3262065 | 113005 | None | V-2 P.No 48 It.No 8.39 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 160.5 | 160.5 | 11753.63 | False | None | None | False | None | False | 1886457.615 | 0 | 3262066 | 113005 | None | V-2 P.No 46 It.No 8.32 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 g/L and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 L/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 197.15 | 197.15 | 837.81 | False | None | None | False | None | False | 165174.2415 | 0 | 3262067 | 113005 | None | V-2 P.No 47 It.No 8.34.3 | Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 63.19 | 63.19 | 371.61 | False | None | None | False | None | False | 23482.0359 | 0 | 3262068 | 113005 | None | V-2 P.No 48 It.No 8.40 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 145.33 | 145.33 | 371.61 | False | None | None | False | None | False | 54006.0813 | 0 | 3262069 | 113005 | None | V-2 P.No 47 It.No 8.34.1 | Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 66.98 | 66.98 | 493.34 | False | None | None | False | None | False | 33043.9132 | 0 | 3262070 | 113005 | None | V-2 P.No 54 It.No 8.82 | Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below:
1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 no.
2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs.
3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs.4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. (Final coat to be done in 1 or 2 layers without gap of time.) | Sqm | 855.58 | 855.58 | 493.34 | False | None | None | False | None | False | 422091.8372 | 0 | 3262071 | 113005 | None | V-2 P.No 181 It.No 18.1 | Providing and supplying aluminium extruded tubular and other alu- minium sections as per the architectural drawings and approved draw- ings of Chief Architect, GoK.The aluminium quality shall be as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. ( The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account).The weight of aluminium extruded section shall be taken for purpose of payment.
| Kg | 514.36 | 514.36 | 2632.5 | False | None | None | False | None | False | 1354052.7 | 0 | 3262072 | 113005 | None | V-2PAGE183ITM18.3 | Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface 2 of approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge. The IGUs shall be assembled in the factory/ workshop of the glass processor. (Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.18.2)For payment, only the actual area of glass on face 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in m2.(i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face 2, 12mm Airgap 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 Light reflection internal 10 to 15light reflection external 10 to 20 shading coefficient (0.250.28) and U value of 3.0 to 3.3 W/ m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement.
| Kg | 3845.68 | 3845.68 | 300.0 | False | None | None | False | None | False | 1153704.0 | 0 | 3262073 | 113005 | None | V-2page183itm18.4 | Extra for openable side / top hung vision glass panels (IGUs) including providing and supplying at site all accessories and hardwares for the openable panels as specified and of the approved make such as heavy duty stainless steel friction hinges, min 4 -point cremone locking sets with stainless steel plates, handles, buffers etc. including necessary stainless steel screws/ fasteners, nuts, bolts, washers etc. all complete as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer- in-Charge.
| Sqm | 5254.8 | 5254.8 | 120.0 | False | None | None | False | None | False | 630576.0 | 0 | 3262074 | 113005 | None | V-2 P.No 24 It.No 7.28.1 | Providing & fixing 10 mm thick plaster of Paris (gypsum anhydrous) ceiling up to a height of 5 m above floor level, over first class kail wood strips 25x6 mm with 10 mm gap in between and reinforced with rabbit wire mesh fixed to wooden frame. Flat surfaces
| Sqm | 1610.06 | 1610.06 | 511.5 | False | None | None | False | None | False | 823545.69 | 0 | 3262075 | 113005 | None | V-2 P.No 28 It.No 7.41 | Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per m2 including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross “T” of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main’T’ at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross ‘T’ of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel of size(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230 mm interval and laying 15 mm thick densified edges calicum silicate ceiling tiles of approved texture in the grid, including, cutting/ making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required. Main ‘T’ runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main ‘T’, bottom exposed with 24 mm of all T sections shall be pre-painted with polyster baked paint, for all heights, as per specifications, drawings and as directed by Engineer-in-Charge.
| Sqm | 2139.58 | 2139.58 | 767.2 | False | None | None | False | None | False | 1641485.776 | 0 | 3262076 | 113005 | None | V-2p45itm8.29 | Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 L/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 357.63 | 357.63 | 558.54 | False | None | None | False | None | False | 199750.6602 | 0 | 3262077 | 113005 | None | V-2page111itm12.92 | Providing& fixing of Openable door made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPV(Thermo Plastic Vulcanized) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the openable frame. The frame having overall size of 60mm x 55mm with GI reinforcement of 1mm thickness and openable sash with overall size of 60mm x 102mm and GI reinforcement of 2mm thickness. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 34 mm. Windows shall be provided with 6mm plain float glass, Standard hardware with 2D/3D hinge & Multi point locking system with Handle. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 900mm 2400mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) | Sqm | 7892.31 | 7892.31 | 36.0 | False | None | None | False | None | False | 284123.16 | 0 | 3262078 | 113005 | None | data rate | Providing and fixing aluminium coated and polyester based netted curtains complete. The work includes cost of all materials, labour charges, lead and lift, etc., complete.
| Sqm | 2596.0 | 2596.0 | 150.0 | False | None | None | False | None | False | 389400.0 | 0 |
| 1718022464000 | 0 | None | None | Buildings | TERRACE FLOOR (CIVIL WORKS) | 22203360.94 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3262079 | 113006 | None | V-1 P.No 17 It.No 2.5.5 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes Form work, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars to be paid separately) M40 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
| Cum | 16318.9 | 16318.9 | 152.27 | False | None | None | False | None | False | 2484878.903 | 0 | 3262080 | 113006 | None | V-1 P.No 17 It.No 2.5.5 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes Form work, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars to be paid separately) M40 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(RCC BEAMS)
| Cum | 15358.96 | 15358.96 | 63.01 | False | None | None | False | None | False | 967768.0696 | 0 | 3262081 | 113006 | None | V-1 P.No 17 It.No 2.5.5 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes Form work, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars to be paid separately) M40 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
RCC SLAB
| Cum | 14399.03 | 14399.03 | 70.9 | False | None | None | False | None | False | 1020891.227 | 0 | 3262082 | 113006 | None | V-1 P.No 17 It.No 2.5.5 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes Form work, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars to be paid separately) M40 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
LINTELS | Cum | 15358.96 | 15358.96 | 1.38 | False | None | None | False | None | False | 21195.3648 | 0 | 3262083 | 113006 | None | V-1 P.No 16 It.no 2.5.1 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork
| Cum | 12268.46 | 12268.46 | 2.12 | False | None | None | False | None | False | 26009.1352 | 0 | 3262084 | 113006 | None | V-1 P.No 18 It.No 2.11 a | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.
| Tonne | 114162.34 | 114162.34 | 36.8 | False | None | None | False | None | False | 4201174.112 | 0 | 3262085 | 113006 | None | 18-19 SR P.No 15 It.No 4.21 | Extra for providing throating or drip moulding to RCC chejjas with plastering ( labour charges only ) as per specifications. Specification No . KBS
| Rmtr | 40.11 | 40.11 | 48.05 | False | None | None | False | None | False | 1927.2855 | 0 | 3262086 | 113006 | None | V-2 P.No 17 It.No 6.32 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.
| Sqm | 1671.78 | 1671.78 | 1293.35 | False | None | None | False | None | False | 2162196.663 | 0 | 3262087 | 113006 | None | V-2 P.No 110 It.No 12.90 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall
be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)"
| Sqm | 8593.73 | 8593.73 | 35.1 | False | None | None | False | None | False | 301639.923 | 0 | 3262088 | 113006 | None | V-2 P.No 86 It.no 11.34A | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding
| Kg | 214.4 | 214.4 | 737.1 | False | None | None | False | None | False | 158034.24 | 0 | 3262089 | 113006 | None | V-2 P.No 77 It.No 11.5.1 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in- Charge.
| Sqm | 5714.69 | 5714.69 | 8.82 | False | None | None | False | None | False | 50403.5658 | 0 | 3262090 | 113006 | None | V-2 P.No 41 It.No 8.4.2 | Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( Inside)
| Sqm | 398.17 | 398.17 | 770.68 | False | None | None | False | None | False | 306861.6556 | 0 | 3262091 | 113006 | None | V-2 P.No 43 It.No 8.10 | Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 269.27 | 269.27 | 901.53 | False | None | None | False | None | False | 242754.9831 | 0 | 3262092 | 113006 | None | V-2 P.No 50 It.No 8.51 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.
| Sqm | 127.62 | 127.62 | 1672.2 | False | None | None | False | None | False | 213406.164 | 0 | 3262093 | 113006 | None | V-2 P.No 42 It.No 8.5.2 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( Outside)
| Sqm | 445.38 | 445.38 | 1546.68 | False | None | None | False | None | False | 688860.3384 | 0 | 3262094 | 113006 | None | V-2P152ITM15.12 | Newly Constructed Roof/Podium with PU Waterproof coating - Above 500 m2-Providing and Applying single component Polyurethane based cold applied seamless waterproofing coating to the RCC surface like Roof & Podium area applied @ 2.4kg/m2 in 3 coats to achieve 1.5mm DFT, including a prime coat of solvent free, medium viscous, epoxy primer @0.2L/m2 and protection with 120gsm Geo-textile over the 7 days cured waterproofing membrane. The Waterproofing material shall have Solids 85%, Tensile strength 2 Mpa as per ASTM D 412, Elongation at break 400confirms to ASTM C 1305 for crack bridging ability (no cracks up to 3.2mm) Shore A Hardness 55 as per ASTM D 2240, Adhesion to peel after water immersion as per ASTM C 794 at 5.2N. Resistance to root penetration as per UNE CN/ TS 14416. The finished cost to include surface preparation, making coving of 50 mm 50mm at all right angles of wall Junction with Polymer Repair Mortar and lay 60gsm Geo-textile over the angle fillet when the first coat in still wet, treatment of cracks completely as per specification.
| Sqm | 1486.74 | 1486.74 | 4481.0 | False | None | None | False | None | False | 6662081.94 | 0 | 3262095 | 113006 | None | V-2 P.No 48 It.No 8.39 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 162.07 | 162.07 | 1672.21 | False | None | None | False | None | False | 271015.0747 | 0 | 3262096 | 113006 | None | V-2 P.No 46 It.No 8.32 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 g/L and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 L/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 199.08 | 199.08 | 928.01 | False | None | None | False | None | False | 184748.2308 | 0 | 3262097 | 113006 | None | V-2 P.No 47 It.No 8.34.3 | Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 63.81 | 63.81 | 43.92 | False | None | None | False | None | False | 2802.5352 | 0 | 3262098 | 113006 | None | V-2 p.No 48 It.No 8.40 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 146.76 | 146.76 | 43.92 | False | None | None | False | None | False | 6445.6992 | 0 | 3262099 | 113006 | None | V-5 P.No 113 It.No 10.1.7 | Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth
of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements
for procuring water for testing) etc. for: PVC pipes 110mm dia., 6 kg/sqcm & class 3
| Rmtr | 524.51 | 524.51 | 240.0 | False | None | None | False | None | False | 125882.4 | 0 | 3262100 | 113006 | None | V-2P82ITM11.16.1 | Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.
| Kg | 173.56 | 173.56 | 7098.0 | False | None | None | False | None | False | 1231928.88 | 0 | 3262101 | 113006 | None | V-2P26ITM7.34 | Providing and fixing 6mm clear I opal white I solar I bronze I blue I green tinted multi wall poly carbonate sheet for tubular structure. The work including cost of all materials, labour charges and hire charges of machineries for cutting, welding, grinding and erection equipments, with all lead and lifts, transportation, loading and unloading and all other incidental charges etc. complete as per specification and directions of the engineer in charge of the work.
| Sqm | 3988.03 | 3988.03 | 141.96 | False | None | None | False | None | False | 566140.7388 | 0 | 3262102 | 113006 | None | V-2P44ITM8.29 | Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 361.16 | 361.16 | 618.67 | False | None | None | False | None | False | 223438.8572 | 0 | 3262103 | 113006 | None | V-5P111ITM7.1.2 | Providing and fixing MS ladder between landings, 45 cms wide using angle iron of specified sizes, 20mm MS bars at 25 cms. centre to centre, with necessary supports of same angle iron etc. as directed, including hand railing on both sides with 25mm dia. GI pipes with angle iron props at 2 mtrs. intervals and 0.5M heigh, including fixing in ground with CC 1:2:4 and two coats of anticorrosive bituminous paint etc. with all lead and lifts etc. complete with: MS angle of 65 x 65 x 10mm
| m | 6126.89 | 6126.89 | 13.2 | False | None | None | False | None | False | 80874.948 | 0 |
| 1718022464000 | 0 | None | None | Buildings | MGPLS(MEDICAL GAS PIPE LINE SYSTEM) | 32800648.8 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3262104 | 113007 | None | APPROVED DATA RATE | OXYGEN MAIN MANIFOLD SYSTEM : 40 cylinder (20+20) Oxygen Manifold should be suitable to withstand a pressure of 140 Kg/Cm2and above along with high pressure copper annealed tail pipes with end Brass adapter suitable for Oxygen Cylinders and manifold. Top frame comprising high pressure copper pipes of size 12mm I.D x 1.5mm wall thick, with high pressure brass fittings made of high tensile brass and connections through non-return values; high pressure copper tail pipes, made of high pressure copper pipe of size 7mm I.D x 1.5mm wall thick. The design of middle and bottom frames should be provided to fit both round and flat bottom cylinders safely. The manifold should be tested (hydraulically) at 3500 psig. | Set | 258237.1 | 258237.1 | 1.0 | False | None | None | False | None | False | 258237.1 | 0 | 3262105 | 113007 | None | Approved DATA Rate | Micro process based Automatic High flow Upto 2200 ltrs/min Oxygen Control Panel. Fully automatic changeover panel 3 SOURCE FULLY AUTOMATIC OXYGEN CONTROL PANEL Working Pressure from the oxygen concentrator plant 4.1 kg/cm2 (Future Provision). Working Pressure from fully automatic control panel. 4.1 kg/cm2. Working Pressure from Emergency manifold system 4.1 kg/cm2. Changeover unit of all 3 sources should be at the pressure from oxygen concentrator plant Below 4.1kg/cm2. Changeover unit of all 3 sources should be at the pressure from main Manifold systemBelow 4.1kg/cm2.Changeoverunit of all 3 sources should be at the pressure from Emergency manifold system Below 4.1kg/cm2. The Control panel shall be of fully integrated type with all safety features inbuilt for high pressure and high flow Upto 2200 ltrs / min Oxygen system. All the electrical circuits should be operated at 12 volts & 24 volts with provision of inbuilt power conversion equipment. The Panel shall have the necessary instruments, gauges, LED Indicators etc. complete with separate indicators far from separate 3 sources. Pressure from oxygen concentrator plant Green signal for Normal pressure & Red signal for Low pressure. Pressure for manifold system Green signal for Normal Pressure & Red signal for low pressure.Left bank Green signal for Normal Pressure & Red for Low pressure. In Right bank Green signal for Normal Pressure & Red for Low pressure.In Emergency manifold Green signal for Normal Pressure & Red for Low pressure. Main Line Green signal for Normal Pressure & Red for Low pressure. | Nos | 231657.6 | 231657.6 | 1.0 | False | None | None | False | None | False | 231657.6 | 0 | 3262106 | 113007 | None | Approved Rate | OXYGEN MAIN MANIFOLD SYSTEM : 20 cylinder (10+10) Oxygen Manifold should be suitable to withstand a pressure of 140 Kg/Cm2and above along with high pressure copper annealed tail pipes with end Brass adapter suitable for Oxygen Cylinders and manifold. Top frame comprising high pressure copper pipes of size 12mm I.D x 1.5mm wall thick, with high pressure brass fittings made of high tensile brass and connections through non-return values; high pressure copper tail pipes, made of high pressure copper pipe of size 7mm I.D x 1.5mm wall thick. The design of middle and bottom frames should be provided to fit both round and flat bottom cylinders safely. The manifold should be tested (hydraulically) at 3500 psig. | Set | 148251.66 | 148251.66 | 1.0 | False | None | None | False | None | False | 148251.66 | 0 | 3262107 | 113007 | None | Approved Rate | NITROUS OXIDE MAIN MANIFOLD SYSTEM Supply, Installation, Testing and commissioning of 4 cylinder (2 + 2) Nitrous Oxide manifold supply with all necessary controls and safety fittings. Make of AKTIV or Equilaent Make complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work. | Set | 106790.0 | 106790.0 | 1.0 | False | None | None | False | None | False | 106790.0 | 0 | 3262108 | 113007 | None | Approved Rate | Nitrous Oxide Emergency Manifold System Supply, Installation, Testing and commissioning of 1 cylinders Nitrous SEMI AUTOMATIC NITROUS OXIDE MAIN MANIFOLD CONTROL PANEL Supply, Installation, Testing and commissioning of 500 lpm deliver capacity manifold control panel, control panel should have all necessary controls and safety fittings. with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work. Nitrous Oxide System - etc., complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work. | Set | 69030.0 | 69030.0 | 1.0 | False | None | None | False | None | False | 69030.0 | 0 | 3262109 | 113007 | None | Approved Rate | Compressed Air System: System For Medical use.
Type : Reciprocating, Air cooled, Oil/ Grease free
Capacity of Piston Displacement : 52.7 cfm 1620 Lpm
Drive : Belt driven
No. of Air Compressors : 2 Nos. (1W + 1S by)
Motor Capacity : 15 HP as required
Receiver Capacity : 2000 liters water capacity
After Reservoir shall have oil seperator and Moisture Receiver type : Automatic Vertical type with inlet, outlet & drain provisions
| Set | 2035500.0 | 2035500.0 | 1.0 | False | None | None | False | None | False | 2035500.0 | 0 | 3262110 | 113007 | None | Approved Rate | Duplex Medical Air Dryer System ( Breathing Air System) (2 Nos of 1 set) 100 CFM
Air Dryer Min Working Pressure should be 4 bar,
Rated Inlet Pressure should be 7 bar
Max Working Pressure should be 16 bar
Supply Voltage Should be 100240 VAC, 50/60 Hz, 1 Ph
Rated Inlet temperature should be 38 deg C
Dryer capable to give should be 40 PDP
Purge Loss 15
Air quality As per NFPA 99
Dual System
Three stage filter (Dessicated drier)
CO & Dew point level as per NFPA 99Bacterial Penetration 0.00001
Failure Indication
Purge Saving control Manual
No refrigerant used
Energy saving Dew point based dryer cycling.
| Set | 135700.0 | 135700.0 | 1.0 | False | None | None | False | None | False | 135700.0 | 0 | 3262111 | 113007 | None | Approved Rate | COMPRESSED AIR BREATHING FILTERATION SYSTEM-3 STAGE The filters Shouldhave maximum contaminant removal efficiency with minimum pressure drop. The filtration system should conform to breathing air filtration as per ISO 8573 Ch I Standard. Total 3-stages of filters Shouldbe used as mentioned below: Stage 1: Oil aerosol contents removal up to 0.5 mg/cum. Stage 2: Oil aerosol contents removal up to 0.01 mg/cum. Stage 3: Oil content removal up to 0.003 mg/cum along with removal of oil vapor and hydrocarbon odor as per ISO 8573 Ch-I Standard. | Set | 81420.0 | 81420.0 | 1.0 | False | None | None | False | None | False | 81420.0 | 0 | 3262112 | 113007 | None | Approved Rate | Air Cooler : Supply, Installation, Testing and Commissioning of 80 CFM Air cooler system, with 3 phase fan (High RPM Fan) suitable for 415 V, 3Phs 50 Hz
| No | 81420.0 | 81420.0 | 1.0 | False | None | None | False | None | False | 81420.0 | 0 | 3262113 | 113007 | None | Approved Rate | VACCUM SUPPLY SYSTEM
The pump installation shall be Duplex system consisting of 2 Nos (1W+1S BY) identical Rotary Vane Type Pumps each of which shall be capable of independently producing designed systems flow rate.
The pump shall be clearly marked with its performance, both its free air displacement and its volumetric throughput. Each pump should have capacity of minimum 4928LPM (300m3/h) i.e., 176 CFM. Pump should be capable of providing a vacuum of not less than 650 mm Hg (87 kPa).
The driving motor shall directly drive the pump unit and it shall be manufactured in accordance with HTM 2022/HTM 02-01 / conforms to IEC Standards. Recommendations suitable for 415 voltes, 3 phase, 50 Hz power supply.Each pump shall have a built in non-return valve and pressure switch such that inadvertent reversal of the motor Should not pressurize the Reservoir or the distribution system protection."
The control panel shall consist of three separate , The system should include vacuum storage reservoir tank, Rated for full vacuum services with the storage capacity of approx 2000Ltr (2Nos Receiver Tank) as per standard recommendation. It should be equipped with an vacuum gauge and provision for manual draining by pass valve. The inside of the tank should be coated with a two-component coating to provide a hard, durable lining for rust
Compartments, two compartments shall hold the motor starters, MCBS ammeters, and hour’s run-meters, for each pump. The remaining compartment shall house the vacuum switches, status monitoring equipment, delay timer and necessary interlock, selector switch with automatic change over, etc., complete with internal wiring using copper conductors. Control Panel system should be front operable. | Set | 1831950.0 | 1831950.0 | 1.0 | False | None | None | False | None | False | 1831950.0 | 0 | 3262114 | 113007 | None | Approved Rate | VACUUM BACTERIAL FILTERATION,
Suitable Medical Vacuum filters are used for removal of bacteria & other contamination from the suction side of vacuum pumps, preventing infection of pump and the atmosphere. These elements shall be of pleated construction giving a high surface area and long operational life. The efficiency to exceed the 0.005% penetration specified in HTM2022 for infectious disease unit.- i.e. complete bacterial removal. Elements shall be fitted in an aluminum housing suitable for various capacities. These are to be internally protected against corrosion by an alocrom treatment. The inner & outer surfaces of the housing are epoxy coated. Complete assembly shall be fitted with a sterilisable drain flask with isolation valve for removal of liquid if any. Differential pressure indicators are to be provided to monitor the status of element. Basics Specifications are as given below, FAC AT Atmospheric : 1850 LPM Size : G1&half 1 Bacterial Removal : 0.0001% penetration when tested to BS: 3928 | Set | 189980.0 | 189980.0 | 1.0 | False | None | None | False | None | False | 189980.0 | 0 | 3262115 | 113007 | None | Approved Rate | Copper Fittings: Supply, Installation, Testing and Commissioning : All copper pipes should be Solid drawn, seamless, deoxidized, non arsenical, half hard, tempered and degreased materials conforming to BS:EN :13348:2001 + A1:2005. Fittings should be made of copper and suitable for a stem of working pressure of 17 bar and Should confirm to BS 864 with specially made for brazed socket type connections.
Copper Pipe 42mm. ODx1.2 mm.thick.
| Rmtr | 3608.44 | 3608.44 | 246.0 | False | None | None | False | None | False | 887676.24 | 0 | 3262116 | 113007 | None | Approved Rate | Copper Fittings: Supply, Installation, Testing and Commissioning : All copper pipes should be Solid drawn, seamless, deoxidized, non arsenical, half hard, tempered and degreased materials conforming to BS:EN :13348:2001 + A1:2005. Fittings should be made of copper and suitable for a stem of working pressure of 17 bar and Should confirm to BS 864 with specially made for brazed socket type connections.Copper Pipe 35mm. ODx1.2 mm.thick.
| Rmtr | 2570.04 | 2570.04 | 444.0 | False | None | None | False | None | False | 1141097.76 | 0 | 3262117 | 113007 | None | Approved Rate | Copper Fittings: Supply, Installation, Testing and Commissioning : All copper pipes should be Solid drawn, seamless, deoxidized, non arsenical, half hard, tempered and degreased materials conforming to BS:EN :13348:2001 + A1:2005. Fittings should be made of copper and suitable for a stem of working pressure of 17 bar and Should confirm to BS 864 with specially made for brazed socket type connections.Copper Pipe 28mm. ODx0.9 mm.thick.
| Rmtr | 1492.7 | 1492.7 | 729.0 | False | None | None | False | None | False | 1088178.3 | 0 | 3262118 | 113007 | None | Approved RAte | Copper Fittings: Supply, Installation, Testing and Commissioning : All copper pipes should be Solid drawn, seamless, deoxidized, non arsenical, half hard, tempered and degreased materials conforming to BS:EN :13348:2001 + A1:2005. Fittings should be made of copper and suitable for a stem of working pressure of 17 bar and Should confirm to BS 864 with specially made for brazed socket type connections.Copper Pipe 22mm. ODx0.9 mm.thick.
| Rmtr | 1156.4 | 1156.4 | 2079.0 | False | None | None | False | None | False | 2404155.6 | 0 | 3262119 | 113007 | None | Approved Rate | Copper Fittings: Supply, Installation, Testing and Commissioning : All copper pipes should be Solid drawn, seamless, deoxidized, non arsenical, half hard, tempered and degreased materials conforming to BS:EN :13348:2001 + A1:2005. Fittings should be made of copper and suitable for a stem of working pressure of 17 bar and Should confirm to BS 864 with specially made for brazed socket type connections.Copper Pipe 15mm. ODx0.9 mm.thick.
| Rmtr | 949.9 | 949.9 | 3762.0 | False | None | None | False | None | False | 3573523.8 | 0 | 3262120 | 113007 | None | Approved Rate | Copper Fittings: Supply, Installation, Testing and Commissioning : All copper pipes should be Solid drawn, seamless, deoxidized, non arsenical, half hard, tempered and degreased materials conforming to BS:EN :13348:2001 + A1:2005. Fittings should be made of copper and suitable for a stem of working pressure of 17 bar and Should confirm to BS 864 with specially made for brazed socket type connections.
Copper Pipe 12mm. ODx0.7 mm.thick.
| Rmtr | 651.36 | 651.36 | 1893.0 | False | None | None | False | None | False | 1233024.48 | 0 | 3262121 | 113007 | None | Approved Rate | OUTLET POINTS Should have terminated properly Double locking DIN type valves which have a parking facility which also avoids interchanging of outlets and keys(Gas specific probes)
Oxygen Terminals - drops of 10 mm dia copper pipe terminated properly DIN type valves which have a parking facility which also avoids interchanging of outlets and keys(Gas specific probes)
| No | 3392.5 | 3392.5 | 466.0 | False | None | None | False | None | False | 1580905.0 | 0 | 3262122 | 113007 | None | Approved Rate | OUTLET POINTS Should have terminated properly Double locking DIN type valves which have a parking facility which also avoids interchanging of outlets and keys(Gas specific probes) Vacuum Terminal - drops of 10 mm dia copper pipe terminated properly DIN type valves which have a parking facility which also avoids interchanging of outlets and keys(Gas specific probes)
| No | 3392.5 | 3392.5 | 348.0 | False | None | None | False | None | False | 1180590.0 | 0 | 3262123 | 113007 | None | Approved Rate | OUTLET POINTS Should have terminated properly Double locking DIN type valves which have a parking facility which also avoids interchanging of outlets and keys(Gas specific probes)
Compressed Air Terminals 4 Bar - drops of 10 mm dia copper pipe terminated properly DIN type valves which have a parking facility which also avoids interchanging of outlets and keys(Gas specific probes)
| No | 3392.5 | 3392.5 | 272.0 | False | None | None | False | None | False | 922760.0 | 0 | 3262124 | 113007 | None | Approved Rate | OUTLET POINTS Should have terminated properly Double locking DIN type valves which have a parking facility which also avoids interchanging of outlets and keys(Gas specific probes)
Compressed Air Terminals 7 Bar- drops of 10 mm dia copper pipe terminated properly DIN type valves which have a parking facility which also avoids interchanging of outlets and keys(Gas specific probes)
| No | 3392.5 | 3392.5 | 12.0 | False | None | None | False | None | False | 40710.0 | 0 | 3262125 | 113007 | None | Approved Rate | OUTLET POINTS Should have terminated properly Double locking DIN type valves which have a parking facility which also avoids interchanging of outlets and keys(Gas specific probes)
Nitous Oxide Terminals - drops of 10 mm dia copper pipe terminated properly DIN type valves which have a parking facility which also avoids interchanging of outlets and keys(Gas specific probes)
| No | 3392.5 | 3392.5 | 13.0 | False | None | None | False | None | False | 44102.5 | 0 | 3262126 | 113007 | None | Approved Rate | ACCESSORIES ALONG WITH CALIBRATION CERTIFICATES.
Oxygen Flow meter with Humidifier Bottle: Flow meter should be Backpressure Compensated. Flow meter should be accurate gas flow measurement and control within a range of 0-15 liters per minute. It should meet strict precision and durability standards. Flow meter body should be made of brass material. Flow tube and shroud components should be made of clear, impact resistant polycarbonate. The humidifier bottle should be unbreakable polycarbonate material and autoclavable at 134 degrees centigrade. The humidifier should have built in safety valve. | No | 2849.7 | 2849.7 | 348.0 | False | None | None | False | None | False | 991695.6 | 0 | 3262127 | 113007 | None | Approved Rate | Single piece wall mounted suction collection & regulation unit. With jar capacity of 600ml each shall be provided at each of the bed side. Jars are should be made of autoclavable materials. The units shall be clamped to the wall using suitable clamps.
| No | 3528.2 | 3528.2 | 336.0 | False | None | None | False | None | False | 1185475.2 | 0 | 3262128 | 113007 | None | Approved Rate | Theatre Vacuum Unit: The unit should comprise of two reusable 2000 ml shatter resistant bottle, each made up of poly carbonate material and fully auto cleavable at 134 degree centigrade. Should have a vacuum regulator with instant ON / OFF switch a three way selector switch with an option to operate either. Left, Right or Both All the above items Should be mounted on a Trolley having a free moving castor wheels. | No | 16962.5 | 16962.5 | 7.0 | False | None | None | False | None | False | 118737.5 | 0 | 3262129 | 113007 | None | Approved Rate | ISOLATION VALVES: Should be 900 turn, ball valves of brass body, duly chrome plated on the outer periphery, SS ball with high quality Teflon seated, connected to pipeline with brass ferrule for easy maintenance. ID of the copper pipe and the ball valve should have same dimensions to avoid the flow friction
Isolation Valves 42 mm
| No | 8142.0 | 8142.0 | 10.0 | False | None | None | False | None | False | 81420.0 | 0 | 3262130 | 113007 | None | Approved Rate | ISOLATION VALVES: Should be 900 turn, ball valves of brass body, duly chrome plated on the outer periphery, SS ball with high quality Teflon seated, connected to pipeline with brass ferrule for easy maintenance. ID of the copper pipe and the ball valve should have same dimensions to avoid the flow friction
Isolation Valves 35 mm
| No | 5428.0 | 5428.0 | 19.0 | False | None | None | False | None | False | 103132.0 | 0 | 3262131 | 113007 | None | Approved Rate | ISOLATION VALVES: Should be 900 turn, ball valves of brass body, duly chrome plated on the outer periphery, SS ball with high quality Teflon seated, connected to pipeline with brass ferrule for easy maintenance. ID of the copper pipe and the ball valve should have same dimensions to avoid the flow frictionIsolation Valves 28 mm
| No | 4071.0 | 4071.0 | 16.0 | False | None | None | False | None | False | 65136.0 | 0 | 3262132 | 113007 | None | Approved Rate | ISOLATION VALVES: Should be 900 turn, ball valves of brass body, duly chrome plated on the outer periphery, SS ball with high quality Teflon seated, connected to pipeline with brass ferrule for easy maintenance. ID of the copper pipe and the ball valve should have same dimensions to avoid the flow friction
Isolation Valves 22 mm
| No | 3392.5 | 3392.5 | 34.0 | False | None | None | False | None | False | 115345.0 | 0 | 3262133 | 113007 | None | Approved Rate | ISOLATION VALVES: Should be 900 turn, ball valves of brass body, duly chrome plated on the outer periphery, SS ball with high quality Teflon seated, connected to pipeline with brass ferrule for easy maintenance. ID of the copper pipe and the ball valve should have same dimensions to avoid the flow friction
Isolation Valves 15 mm
| No | 2714.0 | 2714.0 | 147.0 | False | None | None | False | None | False | 398958.0 | 0 | 3262134 | 113007 | None | Approved Rate | Zonal Valve box three Gas services
An Zonal area valve box should have bellow spec.
Wall mounted M.S. box with powder coated & lockable,
front glass mounting easily visible & using imported brass body quarter turn ball valves using for opening & closing position.
The valve box door cannot be close during valve close position. | No | 18319.5 | 18319.5 | 19.0 | False | None | None | False | None | False | 348070.5 | 0 | 3262135 | 113007 | None | Approved Rate | Zonal Valve box five Gas services
An Zonal area valve box should have bellow spec.
Wall mounted M.S. box with powder coated & lockable,
front glass mounting easily visible & using imported brass body quarter turn ball valves using for opening & closing position.
The valve box door cannot be close during valve close position. | No | 23364.0 | 23364.0 | 8.0 | False | None | None | False | None | False | 186912.0 | 0 | 3262136 | 113007 | None | Approved Rate | Digital Area Alarm for Three Gas Systems.
Micro processor controlled Area Gas alarm panel five Lines, Should audio- visual alarms for each gas used on the floor and come fitted with test and mute button. Running on electricity 220V, these units are suggested to be fitted on each floor as well as areas of heavy usage. It should be fitted with a digital pressure gauge. It indicates low, medium & high pressure sensors.
| No | 35282.0 | 35282.0 | 19.0 | False | None | None | False | None | False | 670358.0 | 0 | 3262137 | 113007 | None | Approved Rate | Digital Area Alarm for Five Gas Systems.
Micro processor controlled Area Gas alarm panel five Lines, Should audio- visual alarms for each gas used on the floor and come fitted with test and mute button. Running on electricity 220V, these units are suggested to be fitted on each floor as well as areas of heavy usage. It should be fitted with a digital pressure gauge. It indicates low, medium & high pressure sensors.
| No | 47495.0 | 47495.0 | 8.0 | False | None | None | False | None | False | 379960.0 | 0 | 3262138 | 113007 | None | Approved Rate | Bed Headed Panel and Railing. 1.5M
Double railing Bed headed panels should have below Specifications.
Accessories 1. IV Stand extendable type with aluminium slider. 2. Monitor stand wall panel mounted. 3. Ward vaccum unit slider. 4. 3/6W LED light fixture. 5. Twpo duplex 230 V,6/16 Amp 6 nos of 6 amps sockets with control switches Electrical Sockets.
Provision Medical Gas Terminal Units as follows. 2.1 Two oxygen outlet.
2.2 One Vacuum outlet. 2.3 One compressed Air outlet 4 Bar. | No | 36639.0 | 36639.0 | 106.0 | False | None | None | False | None | False | 3883734.0 | 0 | 3262139 | 113007 | None | Approved Rate | Surgeon Single Arm Pendant: The material of the Pendent should be Single-armed rotary ceiling mounted surgical Pendent High-strength aluminum alloy. Extension arm 700mm. Loading capacity: 70-150kg. Level degrees rotation:340n.w.:158kg. Should be provision for Gas outlets Oxygen 02 nos, Vaccum 01 nos, Air 4 Bar 01 nos, Air 7 Bar 01 nos, Nitrous Oxide01 nos, Power socket 08 nos, Grounding terminal 01 nos, Platform 03 nos, IV pole 01 nos, Drawer 01 nos. | No | 264615.0 | 264615.0 | 5.0 | False | None | None | False | None | False | 1323075.0 | 0 | 3262140 | 113007 | None | Approved Rate | Anaesthesia Single Arm Pendant: The material of the Pendent should be Single-armed rotary ceiling mounted surgical Pendent High-strength aluminum alloy. Extension arm 700mm.Loading capacity: 70-150kg.Level degrees rotation:340n.w.:158kg. Should be provision for Gas outlets Oxygen 02 nos, Vaccum 01 nos,Air 4 Bar 01 nos,Air 7 Bar 01 nos, Nitrous Oxide01 nos,Power socket 08 nos,Grounding terminal 01 nos,Platform 03 nos, IV pole 01 nos,Drawer 01 nos.
| No | 264615.0 | 264615.0 | 7.0 | False | None | None | False | None | False | 1852305.0 | 0 | 3262141 | 113007 | None | APPROVED RATE | Conversion Kit for Anesthesia for Oxygen. Should have high pressure antistatic tubing which is color coded. - etc., complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work. | Nos | 1652.0 | 1652.0 | 5.0 | False | None | None | False | None | False | 8260.0 | 0 | 3262142 | 113007 | None | APPROVED RATE | Conversion Kit for Anesthesia for Nitrous Oxide. Should have high pressure antistatic tubing which is color coded. - etc., complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work | Nos | 1652.0 | 1652.0 | 5.0 | False | None | None | False | None | False | 8260.0 | 0 | 3262143 | 113007 | None | APPROVED RATE | Digital Area Alarm for Three Gas Systems.
Micro processor controlled Area Gas alarm panel five Lines, Should audio- visual alarms for each gas used on the floor and come fitted with test and mute button. Running on electricity 220V, these units are suggested to be fitted on each floor as well as areas of heavy usage. It should be fitted with a digital pressure gauge. It indicates low, medium & high pressure sensors.
| Nos | 33925.0 | 33925.0 | 2.0 | False | None | None | False | None | False | 67850.0 | 0 | 3262144 | 113007 | None | APPROVED RATE | Zonal Valve box two Gas services
An Zonal area valve box should have bellow spec. Wall mounted M.S. box with powder coated & lockable,Front glass mounting easily visible & using imported brass body quarter turn ball valves using for opening & closing position.
| Nos | 16284.0 | 16284.0 | 2.0 | False | None | None | False | None | False | 32568.0 | 0 | 3262145 | 113007 | None | APPROVED RATE | Should be 900 turn, ball valves of brass body, duly chrome plated on the outer periphery, SS ball with high quality Teflon seated, connected to pipeline with brass ferrule for easy maintenance. ID of the copper pipe and the ball valve should have same dimensions to avoid the flow friction
Isolation Valves 76 mm
| Nos | 11540.4 | 11540.4 | 4.0 | False | None | None | False | None | False | 46161.6 | 0 | 3262146 | 113007 | None | APPROVED RATE | Should be 900 turn, ball valves of brass body, duly chrome plated on the outer periphery, SS ball with high quality Teflon seated, connected to pipeline with brass ferrule for easy maintenance. ID of the copper pipe and the ball valve should have same dimensions to avoid the flow friction
Isolation Valves 54 mm
| Nos | 8826.4 | 8826.4 | 5.0 | False | None | None | False | None | False | 44132.0 | 0 | 3262147 | 113007 | None | APPROVED RATE | Supply, Installation, Testing and commissioning of copper pipe for medical gas services. Pipes shall be priced for all necessary supports, standard fittings. Make of MEX FLOW or Equilaent Make complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work.
Copper Pipe 76mm. ODx1.5 mm.thick.
| Mtr | 8189.2 | 8189.2 | 50.0 | False | None | None | False | None | False | 409460.0 | 0 | 3262148 | 113007 | None | APPROVED RATE | Supply, Installation, Testing and commissioning of copper pipe for medical gas services. Pipes shall be priced for all necessary supports, standard fittings. Make of MEX FLOW or Equilaent Make complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work.
Copper Pipe 54mm. ODx1.2 mm.thick.
| Mtr | 4854.52 | 4854.52 | 168.0 | False | None | None | False | None | False | 815559.36 | 0 | 3262149 | 113007 | None | APPROVED RATE | FULLY AUTOMATIC OXYGEN MANIFOLD CONTROL PANEL Supply, Installation, Testing and commissioning of Fully Automatic O2 Control Panel 1800 lpm deliver capacity manifold control panel, control panel should have all necessary controls and safety fittings. complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work. | Set | 218300.0 | 218300.0 | 1.0 | False | None | None | False | None | False | 218300.0 | 0 | 3262150 | 113007 | None | APPROVED RATE | OXYGEN MANIFOLD SYSTEM :EMERGENY The Control pannel shall be of fully integrated type with all saftety futures inbuilt for high pressure and high flow upto 2200 ltrs / min Oxygen system. 4+4 Cylinder Oxygen Manifold Should be suitable be withstand a pressure of 140 Kg/Cm2and above, along with high pressure copper annealed tail pipes with end Brass adapter suitable for Oxygen Cylinders and manifold. Top frame comprising of high pressure copper pipes of size 12mmI.D x 1.5mm wall thick, with high pressure brass fittings made of high tensile brass and connections through non-return values; high pressure copper tail pipes, made of high pressure copper pipe of size 7mm I.D x 1.5mm wall thick and a single state high pressure high flow regulator connected to a high pressure brass block. The design of middle and bottom frames should be provided to fit both round and flat bottom cylinders safely. The manifold should be tested (hydraulically) at 3500 psig and necessary test certificates should accompany along with the supply.
SEMI AUTOMATIC EMERGENCY OXYGEN MANIFOLD CONTROL PANEL Semi automatic control panels designed for various control functions required during supply of oxygen through the manifold unit. Enclosed in a metal cabinet. This semi automatic control panel is highly efficient in triggering the signal for the Reserve system to go operational in case primary and secondary system fails in emergency. This panel is normally connected in a permanent mode and change over is semi automatic. Some of the features of this pannels are as follows :
Control panel shall be made of M.S.duly powder coated.Easy maintenance.
Highly reliable.
Designed for safety and continuity of flow supply at a constant pressure.
Pressure gauge facility to indicate the gas pressure of each header and pipe line distribution pressure.
Capable to provide a distribution flow rate in excess of 1500LPM.
Should have Incorporation of safety features in case pressure exceeds 100Psi.
| Set | 179124.0 | 179124.0 | 1.0 | False | None | None | False | None | False | 179124.0 | 0 |
| 1718022464000 | 0 | None | None | Buildings | MODULAR OT | 5959768.32 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3262151 | 113008 | None | Approved rate | DESIGN,SUPPLY ERECTION TESTING & COMISSIONING OF CLEAN ROOM SYSTEM
"Providing and fixing 50 mm thick prefabricated walkable stainless steel panels ceiling The panel should have a composite construction of two skins, one side stainless steel 304 grade 0.8 mm thick and other side sheet is PPGI sheet of 0.6 mm thick. And these two sheets are held together with aluminum ‘w’ section of 48mm x 10.2mm for frame work & inner space between two sheets is filled with Puff insulation with density of 40KG per Cubic meter. The panel size should be 1.20Mts x 3.00 Mtrs. The stainless steel surface should be brush / MAT finish with antiglare property. The false ceiling panels are designed in such way that to fit within each other. There shall be minimum joints. If joints are necessary the panels will be jointed each other by using aluminum ‘H ‘ section 29 mm x 42 mm for interlock system. And all panel joints will be sealed by using compressible food grade silicon sealent to ensure air tight vapor tight construction. The false ceiling shall be walkable with provision of service panel. The false ceiling should be fixed to the concrete slab by using 8mm treaded tension bars with adjustable turn buckles, fastener, nuts, bolts etc., complete to the concrete slab.
Coving: Providing corner joint coving for wall to wall used to provide smooth and seamless corner coving buffed aluminium extruded profile R75 ‘C’ cap, L section profile, ‘Z’ section profile.
The required size cut outs for fixing of lights & also for any other services shall be made. The cost includes the cost of all materials, labour charges for fixing, transportation, lead, lift and etc., complete. The works shall be carried out as per the directions of the Engineer in charge.
( Note: The panel should be free from scratches & dents )
MODULAR OT area -8 mtr X6 mtr apprxt.
Say 50.00 Sqm | Sqm | 10354.5 | 10354.5 | 50.0 | False | None | None | False | None | False | 517725.0 | 0 | 3262152 | 113008 | None | Approved Rate | Providing and fixing 50 mm thick prefabricated stainless steel wall panels. The panel should have a composite construction of two skins, one side stainless steel 304 grade 0.8 mm thick and other side sheet is PPGI sheet of 0.6 mm thick and these two sheets are held together with aluminum W section size 48mm x 10.2mm for frame work and inner space between two sheets is filled with Puff insulation with density of 40KG per Cubic meter. The panel size should be 1.20Mts x 3.00 Mtrs. The stainless steel surface should be brush / MAT finish with antiglare property. The wall panels are designed in such way that to fit within each other. There shall be minimum joints. If joints are necessary the panels will be jointed each other by using aluminum H section 29 mm x 42 mm for interlock system. And all panel joints will be sealed by using compressible food grade silicon to ensure air tight vapour tight construction. Coving:Providing corner joint coving used to provide smooth and seamless corner coving buffed Aluminium extruded profile R75 ‘C’ cap, L section profile, ‘Z’ section profile. The covings shall be provided wall to wall, wall to ceiling, wall to floor. The required size cut outs for fixing of control panel and switch plate shall be made. The cost includes the cost of all materials, labour charges for fixing, transportation, lead, lift etc., complete. The works shall be carried out as per the directions of the Engineer in charge.
( Note: The panel should be free from scratches & dents )
6 mtr X 3 mtr X2 Nos. =36 Sqmtr
8 mtr X 3 mtr X2 Nos. =48 Sqmtr
Say 84.00 Sqm
( Door area will be detected form wall panel) | Sqm | 10354.5 | 10354.5 | 84.0 | False | None | None | False | None | False | 869778.0 | 0 | 3262153 | 113008 | None | Approved Rate | Supplying and Fixing STAINLESS STEEL DOOR Providing, fabrication and fixing of Stainless steel door with openable shutter of suitable size. The Door frame section of 50mm x 100mm size is made out of 1.2mm thick Stainless steel sheet of 304 grade. The door shutter of 42 - 45 mm thick by using 0.8mm thick stainless sheet of 304 grade for both sides and the surface of the steel should be MAT finish with antiglare property and having composite construction & the space b/w two sheets is filled with Puff insulation with 40 kg/cum density shall be used to ensure air tight & vapour tight construction. Door shall be provided with automatic drop seal at bottom of door, sealed with high quality neoprene sealing gasket in all edges. The doors are provided with vision panel in double toughened glass size 300mm x 300mm,(6mm thick). All accessories including heavy duty SS ball bearing butt door hinges, SS 304 grade handles- 02 sets, heavy duty door closure, SS concealed Tower Bolt, etc are all approved make. The cost includes the cost of all materials, labour charges for fixing, transportation, lead, lift etc., complete. The works shall be carried out as per the directions of the Engineer in charge.
Srub Door /Dirty utility Door (single leaf)
1 mtr X 2.10 mtr
Say 2.10 Sqmtr | Sqm | 53843.4 | 53843.4 | 2.1 | False | None | None | False | None | False | 113071.14 | 0 | 3262154 | 113008 | None | Approved Rate | Supplying and Fixing HERMATICALLY SEALED STAINLESS STEEL SLIDING DOOR Providing, fabrication and fixing of manually operated hermetically sealed stainless steel sliding door of size1500 x 2100mm. The door shutter of 42 - 45 mm thick by using 0.8mm thick stainless sheet of 304 grade for both sides and the surface of the steel should be MAT finish with antiglare property and having composite construction & the space b/w two sheets is filled with Puff insulation with 40 kg/cum density shall be used to ensure air tight & vapour tight construction. The sliding Door runs on Nylon wheel within an Aluminium extrusion high quality rail complete with required accessories. The door track is constructed from an aluminium extrusion, fixed firmly to the wall. Door shall be provided with automatic drop seal at bottom of door, sealed with high quality neoprene sealing gasket in all edges.
The doors are provided with vision panel in double toughened glass size 300mm x 300mm,(6mm thick)Motarised,sensor operated. All accessories including SS 304 grade handles- 02 sets, SS concealed Tower Bolt, etc., Complete are all approved make. The cost includes the cost of all materials, labour charges for fixing, transportation, lead, lift etc., complete. The works shall be carried out as per the directions of the Engineer in charge. Make:Metaflex | Sqm | 96585.4 | 96585.4 | 3.5 | False | None | None | False | None | False | 338048.9 | 0 | 3262155 | 113008 | None | Approved Rate | Antistatic Epoxy Flooring : Providing and laying 4mm thick anti-static, anti-fungal and anti-bacterial epoxy flooring after preparing the floor surface by removing all loose particles, dirt by using coir brush and vacuum cleaner. Applying one coat of Moisture barrier primer and then applying self-leveling 2mm thick moisture barrier layer to capture the moisture of the existing flooring. Then the anti static grid is laid with conductive granules and copper strips. Then apply one coat of epoxy based primer and allow for dry 6- 8 hours. Then apply epoxy putty and allow for dry 6 8 hours. And then apply 2 mm thick self-leveling epoxy flooring of approved make, colour and shade. The Epoxy flooring should be impact resistance, chemical resistance including abrasion and fumigation with R75mm coving wall to wall, wall to flooring etc., The cost includes cost of material, labour, transportation etc., complete. The works shall be carried out as per the directions of the Engineer in charge. | Sqm | 3835.0 | 3835.0 | 54.0 | False | None | None | False | None | False | 207090.0 | 0 | 3262156 | 113008 | None | Approved Rate | Supplying and Fixingof 2'x2' LED recessed luminarie with…. Watts system wattage. Housing shall be with pressure die cast aluminium alloy with corrosion proof resistant polyester powder coated. Driver operates with voltage range from 100v to 270V 50/60 Hz with short circuit, overload & mis-wring protection. Lumen maintenance of 70% at 50000 Hrs. injection moulded poly carbonate diffuser for better mechanical stability, light transmission & avoid pot hole effect. Junction temperature shall be 70 degree Celsius. Driver is on constant current driver @ 0.06A with PF 0.9, line voltage @ 50Hz, driver efficiency 85% & THD15%. LED Efficiency 130 Im/W & Fixture Efficiency 75lm/w with CRI 75 with injection moulded Polycarbonate lens with 8mm depth. 5 years Warranty against any manufacturing defect working under standard electrical condition. | Each | 9725.56 | 9725.56 | 8.0 | False | None | None | False | None | False | 77804.48 | 0 | 3262157 | 113008 | None | Approved Rate | Supplying and Fixing LED - X-Ray Viewing Screen :X-RAY VIEWING SCREEN: - Two Plate X-Ray View Screen with flicker free illumination having imported LED system for uniform illumination and operated by X-ray film. The system having electrical safety codes for high & Low voltage system. The X ray viewing screen shall be concealed with wall panel.
| Each | 33040.0 | 33040.0 | 1.0 | False | None | None | False | None | False | 33040.0 | 0 | 3262158 | 113008 | None | APPROVED RATE | Supplying and Fixing Magnetic Writing List Board:Magnetic Writing Board of size 940 x 640 x 50 mm comprises of a flush mounted, 1.50 mm thick, white laminate board, bonded to a 10 mm high density fibre board sheet for additional rigidity. Magnetic Writing List Board shall be concealed with wall panel.
| Each | 6903.0 | 6903.0 | 1.0 | False | None | None | False | None | False | 6903.0 | 0 | 3262159 | 113008 | None | Approved Rate | Plenum Laminar Flow :
Supply and installation of Stainless steel 304 grade Plenum LAMINAR FLOW- Plan air Ceiling mounted system with unidirectional airflow,(Air flow velocity of 25 to 35 FPM) Plenum unit, Holding structure & Top plenum are conforming to DIN 4799 / EU14 (Mini pleate HEPA filter) standards for the air distribution system complete with provision for 6 Nos. (Size 1220mmX610mmX90mm thick) HEPA Filters (efficiency 99.97% down to 0.3 micron ), 4000 cfm. The Plenum size is 1800 x 2400mm. The Diffuser is made out of SS 304 Grade material for laminar of filtered air. The complete unit will have factory prepared fine sealing system. It will be perfectly seamless. It will be made out of SS 304 Sheet of required thickness With perforated SS 304 sheet with etc., complete.
| Each | 312700.0 | 312700.0 | 1.0 | False | None | None | False | None | False | 312700.0 | 0 | 3262160 | 113008 | None | Approved Rate | Supplying and Fixing STAINLESS STEEL STORAGE UNIT:Providing and supplying Storage Unit of size 800x1900x350 mm has made of 0.8.mm thick SS304 grade sheet. The exterior openable glass doors shall be made by using 6mm thick toughened glass with lockable & magnetic push-button for easy opening. Removable toughened glass shelves of thickness 6 mm will be provided with the storage units.
| Each | 70800.0 | 70800.0 | 1.0 | False | None | None | False | None | False | 70800.0 | 0 | 3262161 | 113008 | None | Approved Rate | Supplying and Fixing PASS/HATCH BOX:Providing and fixing Hatch box for modular OT in stainless steel SS 304, SS Handles, SS Hinges, View window, Door close/open indication, Electromagnetic door interlocking system based on Microcontroller electronic system for disposal of dirty linen/waste to non-sterile store.(Size 600mm x 600mm x 600mm) with double door inter lock and consisiting of UV lamp, UV lamp on for both door closed, UV lamp off for any door open, CF lamp on any door is open CF lamp off both door closed including cost of conceted accessories.
| Each | 76700.0 | 76700.0 | 1.0 | False | None | None | False | None | False | 76700.0 | 0 | 3262162 | 113008 | None | Approved Rate | Supplying and Fixing OT control Panel 6 Tile : Supply and installation of 6 tile OT control panel with distribution box, control panel will be mounted flush in the theatre wall, comprising of the following
1. Medical gas card
2. Laminar Air flow controls Temperature & humidity indicators, filter status, temperature & humidity control.
3. Digital elapsed timer
4. Hand free phone
5. Digital day timer clock
6. Lighting control panel | Each | 129800.0 | 129800.0 | 1.0 | False | None | None | False | None | False | 129800.0 | 0 | 3262163 | 113008 | None | Approved Rate | Providing & fixing SS304 grade return air grill. The cut out for return air grill size in panel is 600mmX450mm. The cost includes cost of material, labour charges for fixing etc complete.
| Each | 4130.0 | 4130.0 | 4.0 | False | None | None | False | None | False | 16520.0 | 0 | 3262164 | 113008 | None | Approved Rate | SUPPLY ERECTION TESTING & COMISSIONING of Return air riser made out of SS 304 grade with 18 SWG in the clean room area of 1000 CFM and provision for return air collar damper anf grill with all concted accessories.
| Each | 21240.0 | 21240.0 | 4.0 | False | None | None | False | None | False | 84960.0 | 0 | 3262165 | 113008 | None | Approved Rate | Supplying and Fixing Providing and making trap door of size 600 x 600mm in the ceiling panel by cutting. The required frame work shall be made by using Aluminium sections. The cost includes cost of material, labour charges for fixing etc complete.
| Each | 7375.0 | 7375.0 | 1.0 | False | None | None | False | None | False | 7375.0 | 0 | 3262166 | 113008 | None | Approved Rate | AHU's RECYCLE SYSTEM FOR OT AREA AS PER NABH NORMS
SUPPLY ERECTION TESTING & COMISSIONING Air handling units of GSS powder coated sheet metal cabinet type Double skin Recirculatory type 40-45 mm thick,Thermal break,modular construction.Air handling units shall be complete with Backward curved blower having capacity of 3500 t0 4000 cfm (Minimum 25 to 35 ACPH ) with 125 mm capacity, 3.75kw TEFC motor,fan motor drive filter section with 10 microns pre filter,3 microns fine filters, DX coil 6 row section of copper coil with aluminium fins,Mist eleminator, inlet and outlet volume control dampers and bypass dampers with access doors and accessories including 10% Fresh air with module with console type and grill, 20 Microns Fresh air filter. 10% Bleed module with hepa filter,damper and grille, View glass, View lamp, limit switch for door & Pressure port for filter sections & provision to fix pressure port to measure the pressure drop across the filter, ( EFF1 Motor ) coil should be 5. 5 TR x 2 circute with all concted accessories.
| No | 597788.0 | 597788.0 | 1.0 | False | None | None | False | None | False | 597788.0 | 0 | 3262167 | 113008 | None | Approved Rate | AIR COOLED CONDENSER UNIT & COPPER PIPING
SUPPLY ERECTION TESTING & COMISSIONING 5.5 TR Air cooled out door condensing units comprising of semi -hermetic / hermetic reciprocating/scrool compressors with matching air cooled condenser suitable for 3500 to 4000 CFM AHU) provided with necessary controls.like Thermostart , Draier with MS painted stand
| No | 146320.0 | 146320.0 | 2.0 | False | None | None | False | None | False | 292640.0 | 0 | 3262168 | 113008 | None | Approves Rate | GRILLE & DAMPER
SUPPLY ERECTION TESTING & COMISSIONING Collar damper made out of Al. with powder coated as per return air openinig size
| Sqm | 10384.0 | 10384.0 | 2.0 | False | None | None | False | None | False | 20768.0 | 0 | 3262169 | 113008 | None | Approved Rate | SUPPLY ERECTION TESTING & COMISSIONING Aluminium Volume control dampers manual operated, Only for hepa module, unit mouth & branch Ducts
| Sqm | 13924.0 | 13924.0 | 2.0 | False | None | None | False | None | False | 27848.0 | 0 | 3262170 | 113008 | None | Approved Rate | SUPPLY ERECTION TESTING & COMISSIONING Fire Dampers with Fusible Links rated for 72 C for AHU mouth, with fire damper actuator with inter link with AHU controll panel in case of fire AHU motor should stop. | No | 6254.0 | 6254.0 | 1.0 | False | None | None | False | None | False | 6254.0 | 0 | 3262171 | 113008 | None | Approved Rate | SUPPLY ERECTION TESTING & COMISSIONING Fire retardant flexible connections for AHU supply & return air mouth
| No | 5546.0 | 5546.0 | 2.0 | False | None | None | False | None | False | 11092.0 | 0 | 3262172 | 113008 | None | Approved Rate | DUCTING & INSULATION
SUPPLY ERECTION TESTING & COMISSIONING Al. ducting including the supports,selicon sealent with painted MS angle flanges.
22 guage
| Sqm | 2006.0 | 2006.0 | 160.0 | False | None | None | False | None | False | 320960.0 | 0 | 3262173 | 113008 | None | Approved Rate | SUPPLY ERECTION TESTING & COMISSIONING Supply & return air duct Insulation with factory laminated Al. foil class 'O' grade
13 mm thk for return air duct
| Sqm | 920.4 | 920.4 | 80.0 | False | None | None | False | None | False | 73632.0 | 0 | 3262174 | 113008 | None | Approved Rate | SUPPLY ERECTION TESTING & COMISSIONING Supply & return air duct Insulation with factory laminated Al. foil class 'O' grade19 mm thk for supply air duct
| Sqm | 1097.4 | 1097.4 | 90.0 | False | None | None | False | None | False | 98766.0 | 0 | 3262175 | 113008 | None | Approved Rate | Polishield covering with two coats paint for exposed duct
| Sqm | 1038.4 | 1038.4 | 70.0 | False | None | None | False | None | False | 72688.0 | 0 | 3262176 | 113008 | None | Approved Rate | SUPPLY & Fixing 300 dia Insulated flexible connection for grille module & return air raiser
| Rmtr | 979.4 | 979.4 | 20.0 | False | None | None | False | None | False | 19588.0 | 0 | 3262177 | 113008 | None | Approved Rate | 25 mm PVC dia drain piping with supports for AHUs
| Rmtr | 625.4 | 625.4 | 50.0 | False | None | None | False | None | False | 31270.0 | 0 | 3262178 | 113008 | None | Approved Rate | SUPPLY ERECTION TESTING & COMISSIONING Ele.controll panel inter lock with AHUs and 5.5 TR 2 nos condenser unit with TEMP. & RH Controller
For AHU | Set | 12272.0 | 12272.0 | 1.0 | False | None | None | False | None | False | 12272.0 | 0 | 3262179 | 113008 | None | Approved Rate | SUPPLY ERECTION TESTING & COMISSIONING 4 Kw Ele. Heater with RH controller to controll humidity of 50 to 60%
| Set | 66788.0 | 66788.0 | 1.0 | False | None | None | False | None | False | 66788.0 | 0 | 3262180 | 113008 | None | Approved Rate | Supplying and drawing flexble multicore cable manufactured with electroytic grade copper with flexible copper conductor confirming to table 3 class 5 of IS:8130-1984 and PVC insulation and sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990 & confirming to GTP
4C X 6 Sqmm
| Rmtr | 218.3 | 218.3 | 60.0 | False | None | None | False | None | False | 13098.0 | 0 | 3262181 | 113008 | None | Approved Rate | Supplying and drawing flexble multicore cable manufactured with electroytic grade copper with flexible copper conductor confirming to table 3 class 5 of IS:8130-1984 and PVC insulation and sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990 & confirming to GTP
4C X 4 Sqmm
| Rmtr | 177.0 | 177.0 | 60.0 | False | None | None | False | None | False | 10620.0 | 0 | 3262182 | 113008 | None | Approved Rate | Supplying and drawing flexble multicore cable manufactured with electroytic grade copper with flexible copper conductor confirming to table 3 class 5 of IS:8130-1984 and PVC insulation and sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990 & confirming to GTP
4C X 2.5 Sqmm
| Rmtr | 123.9 | 123.9 | 30.0 | False | None | None | False | None | False | 3717.0 | 0 | 3262183 | 113008 | None | Approved Rate | Supplying and drawing flexble multicore cable manufactured with electroytic grade copper with flexible copper conductor confirming to table 3 class 5 of IS:8130-1984 and PVC insulation and sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990 & confirming to GTP
8C X 2.5 Sqmm S.R.
| Rmtr | 348.1 | 348.1 | 30.0 | False | None | None | False | None | False | 10443.0 | 0 | 3262184 | 113008 | None | Approved Rate | Supplying and drawing flexble multicore cable manufactured with electroytic grade copper with flexible copper conductor confirming to table 3 class 5 of IS:8130-1984 and PVC insulation and sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990 & confirming to GTP
4C X 10 Sqmm
| Rmtr | 348.1 | 348.1 | 30.0 | False | None | None | False | None | False | 10443.0 | 0 | 3262185 | 113008 | None | Approved Rate | SUPPLY & Fixing Cable trey
300 width x 50 ht perforated P. No.63 Item No.7.19.2
| Rmtr | 645.46 | 645.46 | 30.0 | False | None | None | False | None | False | 19363.8 | 0 | 3262186 | 113008 | None | Approved Rate | SUPPLY & Fixing Cable trey
Plate COpper Earthing strip 24 x 3 mm connected to existing earthing P.55 Item No.7.3.6
| Rmtr | 617.14 | 617.14 | 50.0 | False | None | None | False | None | False | 30857.0 | 0 | 3262187 | 113008 | None | Approved Rate | SUPPLY & Fixing Cable trey
SUPPLY & FIXING DP Gauge range 0 to 6 mm wg for OT room to monitoring positive pressure
| No | 10089.0 | 10089.0 | 1.0 | False | None | None | False | None | False | 10089.0 | 0 | 3262188 | 113008 | None | Approved Rate | SUPPLY & Fixing Cable trey
DSUPPLY & FIXING DP Gauge range 0 to 50 mm wg for AHU & EAU pre & fine filter section to monitoring pressure drop in the filters
| No | 9735.0 | 9735.0 | 2.0 | False | None | None | False | None | False | 19470.0 | 0 | 3262189 | 113008 | None | Approved Rate | SUPPLY & Fixing Cable trey
Supplying & Fixing Single Arm Rotating OT Pendant: Single ARM 320 Deg Rotating Anesthesia Pendant Complete with Electrical Outlets (8 Nos), Data Points (1 Nos) and Medical Gas Outlets (7 Nos), 1 Monitor Tray, 2 Nos. Shelfs, 2 Nos I V Stand
| No | 194700.0 | 194700.0 | 1.0 | False | None | None | False | None | False | 194700.0 | 0 | 3262190 | 113008 | None | Approved Rate | Supply , installation, testing and commissioning Double arm moveable pendant for surgeon with connected accessories.
The Pendants shall comply with NFPA 99C/HTM 02-01/DIN/EN/ISO 7396-1 as amended up to the last date of receipt of tenders. The support arms shall be extremely robust and revolve on high quality bearings, so that the pendant head glides smoothly and quickly to any desired position.
Double moveable arms (any combination) with total coverage of min 1800 mm and minimum 330 Each arm shall have ability of horizontal movement. Vertical movement shall be motorized and the arm height shall remain at a height greater than 6.5 feet above floor level.
Weight carrying capacity of the arm shall not be less than 180 kg. It shall have electromagnetic/pneumatic brakes.
Each arm shall be capable of minimum 330 of rotation, which can be easily adjusted to suit the desired mode of operation.
The pendant shall be European CE Certified with 4 digit notified body number/US FDA/ETL/UL/BIS certified/listed under medical devices directive.
The Pendant Service Heads shall be modular with minimum 800mm head.The heads shall be capable of accepting a range of shelves, infusion poles, electrical switch/sockers, gas outlets and other required accessories. The Pendant Heads shall support the range of Physiological Monitor Mounting Solutions.
The Pendant Service Heads shall be supplied with medical gas terminal units and 5A/15A or 6A/16 A hybrid sockets.
Pendant shall be supplied with outlets and probes as mentioned below.
Oxygen Outlets -2 nos , Medical Air Outlets 4 bar -1 no,Vacuum Outlets -2 nos
,Air(7bar) outlets-01 no, CO2 outlets-01 nos, Electrical Sockets-10 no, Adjustable shelf with two rails one on each side -3 no, Data socket RJ-45 -2 nos, IV Fluid Pole with 2 hooks -1 no, (Pole shall be capable of stacking 4 syringe pumps), Nitrous oxide outlets-1 no.
Pendent shall provide cut-outs for patch panel in integrated OTs (only for integrated OTs.)
Surgeon pendant shall have NIST connection for all gases to conncet the MGPLS system.
| No | 430700.0 | 430700.0 | 1.0 | False | None | None | False | None | False | 430700.0 | 0 | 3262191 | 113008 | None | Approved Rate | Scrub Station
MOT SCRUB STATION (minimum size 1500 mm)
supply , installation and commissioning of compact surgical scrub sink shall be designed for use in OT area for pre-procedural scrub. Double sink combination shall be provided. Fabricated from heavy gauge type 304 stainless steel (minimum thicknes 1.5 mm) and shall be of seamless welded construction, polished to a satin finish.With a front access panel which shall be easily removable for access to the water controlled valve, waste connections, stoppers and strainers. Hands free operation shall include infra-red sensors with programmable adjustment. .Thermostatic mixing, valve control shall be located behind the access panel and it shall maintain constant water temperature.Timing shall be adjustable to meet individual application requiements.(built in with timer setting from 1 to 10 mic)It shall be provided with infrared sensors, thermostatic control taps with fail safe temprerature controls. All units shall have reduced anti-splash fronts.Knee/foot operated switch shall be provided additionally with all connected accessories.
| No | 278480.0 | 278480.0 | 1.0 | False | None | None | False | None | False | 278480.0 | 0 | 3262192 | 113008 | None | APPROVED RATE | Supply , installation, testing and commissioning OT surgical Lighting system with connected accessroies
MOT surgical lighting system shall provide an ideal combination of brightness, manoeuvrability and shadow resolution without sacrificing colour and accuracy through a consistent LED technology.
Such lighting system shall have the following technical specifications:
a) Number of light heads : Two
b) Rotation system : 360
c) Colour temperature range : 3800K to 5000K variable colour temperature.
d) CRI : 93 Ra.
e) LED's : Low temp . 3 Colours combination.
f) LED bulb life :50,000 hrs.
g) Field size diameter : 20 to 28 cm
h) Working range : 750 to 1100 mm
i) Focus : Adjustable 100mm 250mm.
j) Illumination leve l: minimum 160,000 lux (both for major dome and minor dome separately).
k) Controls : control panel ( two:one on the wall and other on dome/ digital with wireless remote).
l) Power supply : 220 V/ 50Hz AC | Nos | 413118.0 | 413118.0 | 1.0 | False | None | None | False | None | False | 413118.0 | 0 |
| 1718022464000 | 0 | None | None | Buildings | Furniture Work | 20241063.67 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3262193 | 113009 | None | APPROVED RATE | Providing and fixing storage unit Specifications : Top - Made of 25mm thick E1 grade pre-laminated particle board . & Body - Made of 18mm thick pre-laminated particle board with openable shutters and Aluminium Finish C- handles + lock and keys.Size : 1200mm(W) x 600mm(D) x 2100mm(H) of approved shade and colour etc., complete the rate includes cost of all materials, labour charges, complete as per specification. | Sqm | 15238.52 | 15238.52 | 414.54 | False | None | None | False | None | False | 6316976.0808 | 0 | 3262194 | 113009 | None | APPROVED RATE | Table : Providing and fixing Executive tables Type : Loose Furniture Table Top : 25mm thick E1 grade pre-laminated particle board table top with matching edgebanding and Aluminum flip up provision of Size:500mm(W) x135mm(D) Anodized finish. Understructure : Aluminium powder coated SOLE Legs (98 degree slant or 90 degree stright Legs) with die cast brackets and MS Powder coated 40x30mm beams are considered to support table top. Metal Modesty : MS powder coated metal modesty is considered in main spine at below table top. Wire Management : MSPowder coated wiretray with switch plate 150D 300D120H and vertical cable risers are considered for wire management. Side Storage Specifications : 400mm width drawer unit 700mm width open shelfs. Top:- Made of 25mm thick E1 grade pre laminated particle board. Body:- Made of 18mm thick prelaminated particle board with openable shutters and aluminum finish C handles lock and keys. | Set | 45982.6 | 45982.6 | 42.0 | False | None | None | False | None | False | 1931269.2 | 0 | 3262195 | 113009 | None | APPROVED RATE | Table : Providing and fixing Executive Type : Loose Furniture Table Top : 25mm thick E1 grade pre-laminated particle board table top with matching edgebanding and Aluminum flip up provision of Size:- 500mm(W) x135mm(D) Anodized finish. Understructure : Aluminium powder coated SOLE Legs (98 degree slant or 90 degree stright Legs) with die cast brackets and MS Powder coated 40x30mm beams are considered to support table top. Metal Modesty : MS powder coated metal modesty is considered in main spine at below table top. Wire Management : MS-Powder coated wiretray with switch plate 150D/300D*120H and vertical cable risers are considered for wire management. Side Storage Specifications : 400mm width drawer unit + 700mm width open shelfs. Top:- Made of 25mm thick E1 grade pre-laminated particle board. Body:- Made of 18mm thick prelaminated particle board with openable shutters and aluminum finish C- handles + lock and keys.
Table 1500 mm x 750 mm x 750 mm ht
| Set | 29500.0 | 29500.0 | 17.0 | False | None | None | False | None | False | 501500.0 | 0 | 3262196 | 113009 | None | APPROVED RATE | VISTIORS CHAIRS etc, including with all lead & lift, loading & unloading, tools, plants, cost of materials, labour and other incidental charges etc., complete as per specification and as per the directions by the Engineer in charge of the work | No | 10738.0 | 10738.0 | 84.0 | False | None | None | False | None | False | 901992.0 | 0 | 3262197 | 113009 | None | APPROVED RATES | Providing and fixing of Three Seater Stainless Steel Waiting Chair complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work. - etc., complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work. | No | 42480.0 | 42480.0 | 149.0 | False | None | None | False | None | False | 6329520.0 | 0 | 3262198 | 113009 | None | APPROVED RATE | Optima Chairs with High Back with mesh and lumber support SEAT/BACK ASSEMBLY: The Cushioned seat assembly consists of seat outer (material-30% Glass Fiber Filled Nylon)& upholstered Seat inner (material- Poly Propylene) with moulded Polyurethane foam & polyester fabric. The Net Back is made up of Back outer (material-Glass Fiber Filled Nylon)& Back inner (material- PP) upholstered with polyester Mesh fabric. FULL BACK SIZE: 46.5 cm. (W) x 60.0 cm. (H) SEAT SIZE : 51.0 cm. (W) x 49.0 cm. (D) POLYURETHANE FOAM: The Polyurethane foam is moulded with density = 45 +/- 2 kg/m , ) ARMRESTS : The armrest is having two adjustment, Height and Depth. Height adjustment is provided in Aluminum structure of armrest which is connected to Aluminum Back spine And is operated by button. The depth adjustment is provided in pad which is fixed to armrest structure. Armrest Top is made up of PU molded over plastic inner. LUMBAR SUPPORT ASSEMBLY: The Lumbar suport assembly consists of lumbar spine (material-Glass Fiber Filled Nylon) which is fixed to Aluminum Back spine. The Lumbar pad (material- Poly Propylene) is fixed to lumbar spine through lumbar Pad support. Lumbar Support Assembly has height adjustment of 50mm. Neck-rest ASSEMBLY: The Neck-rest assembly consists of upholstered Neck-rest inner (material- Poly Propylene) etc., complete as per the direction of Engineer in charge of the work. | No | 21830.0 | 21830.0 | 62.0 | False | None | None | False | None | False | 1353460.0 | 0 | 3262199 | 113009 | None | APPROVED RATE | STAFF CHAIRS : Supplying HIGH BACK Chair Blue mango with contact crome flex back chair with co-active synchro, gas lift, revolving, tilting, and height adjustable fully cushioned medium back chairs and two way adjustable arms. prior confirmation shall be obtain from the officer / Architect for approval. | No | 14750.0 | 14750.0 | 63.0 | False | None | None | False | None | False | 929250.0 | 0 | 3262200 | 113009 | None | APPROVED RATE | Providing and fixing Centre Teapoy of size of 900 x 600 x 750 mm oval shape as per principal chief architecht dwg no 120816/16 made out of good quality Burma Teak wood legs of cross section 50 x 10 mm and side bars of 50 x 60mm with 12mm thick modi guard glass top wtih edge grainding on polishing of oval shape of 900 x 600mm as per dwg. Polished with melamine finish in spray with necessary compressor Complete with all materials, labour, leads lifts etc and directed by Engineer in charge. Type : Loose Furniture. Table Top : 25mm thick E1 grade pre-laminated particle board table top with matching edgebanding and Alluminium Flipup Provision Of Size : 500mm(W) x 135mm(H) is Anodized Finish Considered. Understructure : Aluminium powder coated SOLE Legs (98 degree slant or 90 degree stright Legs) with die cast brackets and MS Powder coated 40x30mm beams are considered to support table top. Modesty : MS powder coated metal modesty is considered in main spine at below table top. Wire Management : MS-Powder coated wiretray with switch plate 150D/300D*120H and vertical cable risers are considered for wire management. | Each | 26550.0 | 26550.0 | 4.0 | False | None | None | False | None | False | 106200.0 | 0 | 3262201 | 113009 | None | APPROVED RATE | DRINKING WATER COOLER : Providing and installing water cooler ss body and ss tank with specification Storage Capacity 80 Ltr, Normal cooling capacity 40Ltr, No of Faucets 2nos, Dimensions (MM) 665W x 480 D x 1210H, weight 47kg, Glasses Per hr 200Ltr, Refrigerant R-134a, current (amps)2.50, water over flow 1/2BSP, Typer of Compresser REIP. Including UV Corbon & Sediment filter of 250L PH water Purifier Fixing Seperatly duly connect. The rate to includ of water piping From OHT To Necessary drainage system for out let, angle cock system for as per specification. | No | 100300.0 | 100300.0 | 4.0 | False | None | None | False | None | False | 401200.0 | 0 | 3262202 | 113009 | None | APPROVED RATE | Providing and fixing meeting table consisting of 25 mm thick PLPB table top edge bounded, 25 mm thick PLPB with edge bonded End table, 18 mm thick PLPB with edge bonded Modesty, Hardware-Minifix assembly and screw leg, as per specifications, drawings and as directed by Engineer in charge. 2400 mm Dia x 1200 mm D x 750 mm Ht (12 seater) | No | 44930.25 | 44930.25 | 3.0 | False | None | None | False | None | False | 134790.75 | 0 | 3262203 | 113009 | None | APPROVED RATE | Providing and fixing woode storage unit one side laminate with 18 mm PLY/PLPB edge bound for body, 18mm PLY/PLPB with openable shutters and individual locking system for shutter, 9 mm PLY with edge bound for rear portion with Hafele fitting hingers, Hafele locks, Minifix assembly, screw legs, Handles and tower bolt, complete as per specifications, drawings and as directed by Engineer in charge. | No | 11429.95 | 11429.95 | 37.0 | False | None | None | False | None | False | 422908.15 | 0 | 3262204 | 113009 | None | APPROVED RATE | Providing and fixing 450mmw x 450 mmd x 685 mmht) Mobile pedestal unit-WOODEN with 18mm thick PLPB with edge bonded for body, Two equal drawer and filing drawer with centralized locking system, Telescopic channels, castors, Handles and lock, etc., complete as per specifications, drawings and as directed by Engineer in charge. | No | 9044.57 | 9044.57 | 12.0 | False | None | None | False | None | False | 108534.84 | 0 | 3262205 | 113009 | None | APPROVED RATE | Single Cot (Size :1950 x 900 x 450 ) Structure made of 100 x S0mm & 50 x S0mm weII seasoned Hard wood with provison of back rest in 18mm thick fully marine grade plywood as per drawings. Hard wood structure polish, with necessary staining, sanding and finishing with Coir and Foam Matters 5 Complete withall materials, labours, leads lifts etc and directed by Engineer in charge. | No | 24190.0 | 24190.0 | 27.0 | False | None | None | False | None | False | 653130.0 | 0 | 3262206 | 113009 | None | APPROVED RATE | PROVIDING ALL SAFE OFFICE LOCKER STEEL ALMIRAH (900X1800X600). depth with 5 shelves of 14 gauge powder coated the rate including one locker | No | 30066.53 | 30066.53 | 5.0 | False | None | None | False | None | False | 150332.65 | 0 |
| 1718022464000 | 0 | None | None | Buildings | FIRE FIGHTING WORKS | 31804663.72 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3262207 | 113010 | None | V-6 P.No 86It.No 15.79.1 | Supply, erection, testing & commissioning of electrical motor driven end suction back pull out centrifugal pump capable of delivering,adequate LPM at required head. when running at 2900 rpm directly coupled to TEFC electrical motor of adequate HP to operate on 400/440 V 3 phase, 50 cycles AC supply with required foundation for pump, a terminal box suitable for reception, common bed plate with necessary anti vibration pads, necessary foundation bolts and accessories,neoprine gaskets (16 kg/sq.cm) Control panel is excluded.Required GA drawingfor the pump/ foundation shall be
submitted by the contractor. (2850 lpm at 70m head) | No | 415065.0 | 415065.0 | 2.0 | False | None | None | False | None | False | 830130.0 | 0 | 3262208 | 113010 | None | V-6 P.No 87 It.No 15.80.1 | Supply, installation, testing & commissioning of diesel engine driven pump, horizontal mounted, Horizontal spiltcase centrifugal single stage pump, capable of delivering required flow at required head when running at 1800 RPM with adequate BHP automatic diesel engine driven pumpset having the residential silencer system and other accessories like fuel tank, necessary radiator cooling system, flanges, neoprene gaskets (16.0 kg/sqcm), 200 litres fuel storage tank with piping, valves as per detailed specification and two separate starting mechanisms (automatic starting by battery power, electric starting motor as well as manual starting by electric start motor) common bed plate with anti vibration pads, necessary foundation, foundation bolts etc., complete in all respects as per the detailed specifdication. Control panel excluded. Required GA drawingfor the pump shall be submitted by the contractor. Required GA drawingfor the pump/ foundation shall be
submitted by the contractor.(2850 lpm at 70m head) | No | 786765.0 | 786765.0 | 1.0 | False | None | None | False | None | False | 786765.0 | 0 | 3262209 | 113010 | None | V-6 P.No 88 It.No 15.85 | Supplying, Installing testing & commissioning electrically driven jockey pump of capacity 180.0 Lmpm at 75.0m head with all the necessary accessories viz. Pressure guages etc. operating on 3Ph 50Hz, 400/440V AC supply including
foundation bolt etc. complete. Control panel shall be as per item No.87, including cost of materials, labour, usage charges of machinery complete as per specifications. | No | 105315.0 | 105315.0 | 1.0 | False | None | None | False | None | False | 105315.0 | 0 | 3262210 | 113010 | None | V-6 P.No 97 It.No 15.139 | Supplying Installing testing and commissiong COMMON Control panel for fire fighting system consiting of electrical motor driven 60HP Main fire pump, Diesel engine driven pump 60 HP Sprinkler pump 50HP & Jockey pump 25HP
| Unit | 344442.0 | 344442.0 | 1.0 | False | None | None | False | None | False | 344442.0 | 0 | 3262211 | 113010 | None | V-6 P.No 94 It.No 15.126 | SITC of Gun metal BALL VALVE SIZE OF 19/20 mm dia - etc., complete as per specificaiton with all lead and lift, loading unloading, labour, hire charges of machineries and all such incidental charges necessary for successful completion of work and as per directions of the Engineer-in-charge of the work
| No | 1177.05 | 1177.05 | 8.0 | False | None | None | False | None | False | 9416.4 | 0 | 3262212 | 113010 | None | V-6 P.No 94 It.no 15.127.2 | Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13039 of following sizes as required 150mm dia
| No | 15487.5 | 15487.5 | 9.0 | False | None | None | False | None | False | 139387.5 | 0 | 3262213 | 113010 | None | V-6 P.No 94 It.No 15.127.3 | Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13039 of following sizes as required 100mm dia
| No | 11151.0 | 11151.0 | 5.0 | False | None | None | False | None | False | 55755.0 | 0 | 3262214 | 113010 | None | V-6 P.No 94 It.No 15.127.4 | Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13039 of following sizes as required 80mm dia
| No | 11151.0 | 11151.0 | 2.0 | False | None | None | False | None | False | 22302.0 | 0 | 3262215 | 113010 | None | V-6 P.No 95 It.No 15.128.2 | Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :150 mm dia
| No | 14248.5 | 14248.5 | 6.0 | False | None | None | False | None | False | 85491.0 | 0 | 3262216 | 113010 | None | V-6 P.No 95 It.No 15.128.3 | Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :100 mm dia
| No | 8821.68 | 8821.68 | 2.0 | False | None | None | False | None | False | 17643.36 | 0 | 3262217 | 113010 | None | V-6 P.No 95 It.No 15.128.4 | Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :80 mm dia
| No | 6814.5 | 6814.5 | 2.0 | False | None | None | False | None | False | 13629.0 | 0 | 3262218 | 113010 | None | V-6 P.No 95 It.No 15.129.1 | Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia
holes with stainless steel flange.200mm dia | No | 30355.5 | 30355.5 | 3.0 | False | None | None | False | None | False | 91066.5 | 0 | 3262219 | 113010 | None | V-6 P.No 95 It.No 15.128.3 | Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :100 mm dia | No | 15351.21 | 15351.21 | 1.0 | False | None | None | False | None | False | 15351.21 | 0 | 3262220 | 113010 | None | V-6 P.No 96 It.No 15.136 | Supplying and fixing air vessel made of 250 mm dia, 8mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain
arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and painting with synthetic enamel paint of approved shade
as required. | No | 37170.0 | 37170.0 | 1.0 | False | None | None | False | None | False | 37170.0 | 0 | 3262221 | 113010 | None | V-6 P.no 96 It.No 15.132 | Pressure guage of 150 mm dia including Isolation Valve and forged siphon Tube including with all accssories as per IS:Spec.
| No | 3593.1 | 3593.1 | 3.0 | False | None | None | False | None | False | 10779.3 | 0 | 3262222 | 113010 | None | V-6 P.No 95 It.No 15.131 | Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required.
| No | 2416.05 | 2416.05 | 6.0 | False | None | None | False | None | False | 14496.3 | 0 | 3262223 | 113010 | None | VOL-2,P.No 82,It.No 11.16.2 | Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials,labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.
| Kg | 182.13 | 182.13 | 300.0 | False | None | None | False | None | False | 54639.0 | 0 | 3262224 | 113010 | None | BSR 21-22 Itm 32.14 | FIREFIGHTING ELECTRICALSupply of the Following XLPE armoured cable 1100 V Grade with ISI mark stranded / solid, aluminimum conductor complete with crimping type Lugs and Glands etc completed.
3.5 Core 95.00 Sq.mm.Main Panel Electrical Pump
| Km | 636895.56 | 636895.56 | 0.1 | False | None | None | False | None | False | 63689.556 | 0 | 3262225 | 113010 | None | BSR 21-22 It.No 32.05 | FIREFIGHTING ELECTRICALSupply of the Following XLPE armoured cable 1100 V Grade with ISI mark stranded / solid, aluminimum conductor complete with crimping type Lugs and Glands etc completed.4.0 Core 16.00 Sq.mm.Main Panel to Jockey
| Rmtr | 227284.64 | 227284.64 | 0.2 | False | None | None | False | None | False | 45456.928 | 0 | 3262226 | 113010 | None | Least Quotation Rate | 12 Core x 2.5Sqmm For Main Panel to DG
| Rmtr | 684.4 | 684.4 | 50.0 | False | None | None | False | None | False | 34220.0 | 0 | 3262227 | 113010 | None | VOL-2 P.no 3 It.No 1.17.3 | 3 Core x 1.5Sqmm Pressure Switch
| Rmtr | 117.71 | 117.71 | 70.0 | False | None | None | False | None | False | 8239.7 | 0 | 3262228 | 113010 | None | V-6 P.No 38 It.No 9.4.6 | Supplying, installation, testing & commissioning of 12V .AH
batteries in poly propylene container for D.G. sets. Low maintenance
batteries, plate type. (150 AH capacity)
| No | 34923.69 | 34923.69 | 1.0 | False | None | None | False | None | False | 34923.69 | 0 | 3262229 | 113010 | None | ITEM 15.85 | Supplying Installing, testing and commissioning of63mm mm dia double headed Gun mental Hydrant Valve with flanged inlet 2Nos, stop valve, spindle and cast iron hand wheel. It has a 2 Nos female instantaneous outlet with blank cap and is hydrostatically tested to 21 Kgf/cm2 pressure having a flow rate of 900 LPM at 7 Kgf/cm2 of pressure confirms to IS : 2190 with blank cap and wheel as per IS 5290 etc. including cost of materials, labour, usage charges of machinery complete as per specifications. complete
| No | 22921.5 | 22921.5 | 15.0 | False | None | None | False | None | False | 343822.5 | 0 | 3262230 | 113010 | None | CPWD SR 21-22 P.No 18 It.No 4.1.4 | Supplying and installing following size of perforated painted with powder cating m.s. cable trays with perforation not more than 17.5% in convenient sections, joined with connectors, suspended from the ceiling with m.s. suspenders including bolts & nuts, painting suspendrrs etc as required.
| Rmtr | 962.7 | 962.7 | 100.0 | False | None | None | False | None | False | 96270.0 | 0 | 3262231 | 113010 | None | V-6 P.No 54 It.No 12.58.2 | GI/Copper strips for grounding connections, using necessary fixing
materials as required. (25 x 3 mm GI strip) | Rmtr | 101.6 | 101.6 | 150.0 | False | None | None | False | None | False | 15240.0 | 0 | 3262232 | 113010 | None | V-6 P.No 89 It.No 15.86 | Supplying Installing, testing and commissioning of Gun metal AIR RELEASE VALVE SIZE OF 25mm dia including cost of materials, labour, usage charges of machinery complete as per specifications. complete
| Each | 1858.5 | 1858.5 | 1.0 | False | None | None | False | None | False | 1858.5 | 0 | 3262233 | 113010 | None | V-6 P.No 94 It.No 15.125 | SITC of Gun metal BALL VALVE SIZE OF 25mm dia - etc., complete as per specificaiton with all lead and lift, loading unloading, labour, hire charges of machineries and all such incidental charges necessary for successful completion of work and as per directions of the Engineer-in-charge of the work
| No | 1486.8 | 1486.8 | 8.0 | False | None | None | False | None | False | 11894.4 | 0 | 3262234 | 113010 | None | V-6 P.No 91 It.No 15.97.3 | Supply, Installation testing and commissioning of approved make heavy quantity (Class 'C') confirming to as per IS1239 Such as Tees elbows check nuts unions,Flanger, Nipples etc. including cutting welding, Trending fixing on walls, cealing (Using 41-Tech pipe/M.S.angle supports work includes two coats of metal primer and two coats of Red enamel paint etc.
150 mm dia
| Rmtr | 4832.1 | 4832.1 | 1450.0 | False | None | None | False | None | False | 7006545.0 | 0 | 3262235 | 113010 | None | V-6 P.No 91 It.No 15.97.4 | Supply, Installation testing and commissioning of approved make heavy quantity (Class 'C') confirming to as per IS1239 Such as Tees elbows check nuts unions,Flanger, Nipples etc. including cutting welding, Trending fixing on walls, cealing (Using 41-Tech pipe/M.S.angle supports work includes two coats of metal primer and two coats of Red enamel paint etc.
100 mm dia
| Rmtr | 3531.15 | 3531.15 | 450.0 | False | None | None | False | None | False | 1589017.5 | 0 | 3262236 | 113010 | None | V-6 P.No 91 It.No 15.97.5 | Supply, Installation testing and commissioning of approved make heavy quantity (Class 'C') confirming to as per IS1239 Such as Tees elbows check nuts unions,Flanger, Nipples etc. including cutting welding, Trending fixing on walls, cealing (Using 41-Tech pipe/M.S.angle supports work includes two coats of metal primer and two coats of Red enamel paint etc.
80 mm dia
| Rmtr | 2849.7 | 2849.7 | 500.0 | False | None | None | False | None | False | 1424850.0 | 0 | 3262237 | 113010 | None | V-6 P.No 91 It.No 15.97.6 | Supply, Installation testing and commissioning of approved make heavy quantity (Class 'C') confirming to as per IS1239 Such as Tees elbows check nuts unions,Flanger, Nipples etc. including cutting welding, Trending fixing on walls, cealing (Using 41-Tech pipe/M.S.angle supports work includes two coats of metal primer and two coats of Red enamel paint etc.
65 mm dia
| Rmtr | 2106.3 | 2106.3 | 400.0 | False | None | None | False | None | False | 842520.0 | 0 | 3262238 | 113010 | None | V-6 P.No 91 It.No 15.97.7 | Supply, Installation testing and commissioning of approved make heavy quantity (Class 'C') confirming to as per IS1239 Such as Tees elbows check nuts unions,Flanger, Nipples etc. including cutting welding, Trending fixing on walls, cealing (Using 41-Tech pipe/M.S.angle supports work includes two coats of metal primer and two coats of Red enamel paint etc.
50 mm dia
| Rmtr | 1610.7 | 1610.7 | 450.0 | False | None | None | False | None | False | 724815.0 | 0 | 3262239 | 113010 | None | V-6 P.No 91 It.No 15.97.8 | Supply, Installation testing and commissioning of approved make heavy quantity (Class 'C') confirming to as per IS1239 Such as Tees elbows check nuts unions,Flanger, Nipples etc. including cutting welding, Trending fixing on walls, cealing (Using 41-Tech pipe/M.S.angle supports work includes two coats of metal primer and two coats of Red enamel paint etc.
40 mm dia
| Rmtr | 1300.95 | 1300.95 | 450.0 | False | None | None | False | None | False | 585427.5 | 0 | 3262240 | 113010 | None | V-6 P.No 91 It.No 15.97.9 | Supply, Installation testing and commissioning of approved make heavy quantity (Class 'C') confirming to as per IS1239 Such as Tees elbows check nuts unions,Flanger, Nipples etc. including cutting welding, Trending fixing on walls, cealing (Using 41-Tech pipe/M.S.angle supports work includes two coats of metal primer and two coats of Red enamel paint etc.
32 mm dia
| Rmtr | 991.2 | 991.2 | 1200.0 | False | None | None | False | None | False | 1189440.0 | 0 | 3262241 | 113010 | None | V-6 P.No 91 It.No 15.97.10 | Supply, Installation testing and commissioning of approved make heavy quantity (Class 'C') confirming to as per IS1239 Such as Tees elbows check nuts unions,Flanger, Nipples etc. including cutting welding, Trending fixing on walls, cealing (Using 41-Tech pipe/M.S.angle supports work includes two coats of metal primer and two coats of Red enamel paint etc.
25 mm dia
| Rmtr | 867.3 | 867.3 | 2380.0 | False | None | None | False | None | False | 2064174.0 | 0 | 3262242 | 113010 | None | V-6 P.No 91 It.No15.98.2 | Wraping and Galing of U/G pipe line work includes one coat of anti corrossion paint (Black) and two coats of Bituminous cloth. including cost of materials, labour, usage charges of machinery complete as per specifications. - 150 mm dia
| Rmtr | 495.6 | 495.6 | 1000.0 | False | None | None | False | None | False | 495600.0 | 0 | 3262243 | 113010 | None | V-6 P.No 91 It.No15.98.3 | Wraping and Galing of U/G pipe line work includes one coat of anti corrossion paint (Black) and two coats of Bituminous cloth. including cost of materials, labour, usage charges of machinery complete as per specifications. - 100 mm dia
| Rmtr | 309.75 | 309.75 | 150.0 | False | None | None | False | None | False | 46462.5 | 0 | 3262244 | 113010 | None | V-6 P.no 94 It.No 15.127.3 | Supplying, installing , testing and commissioning approved make CI butterfly valves of 100mm diameter confirming to IS 13039 with necessary nuts & bolts etc., complete - etc., complete as per specificaiton with all lead and lift, loading unloading, labour, hire charges of machineries and all such incidental charges necessary for successful completion of work and as per directions of the Engineer-in-charge of the work
| No | 11151.0 | 11151.0 | 16.0 | False | None | None | False | None | False | 178416.0 | 0 | 3262245 | 113010 | None | V-6 P.No 94 It.No 15.127.6 | Supplying, installing , testing and commissioning approved make CI butterfly valves of 50mm diameter confirming to IS 13039 with necessary nuts & bolts etc., complete - etc., complete as per specificaiton with all lead and lift, loading unloading, labour, hire charges of machineries and all such incidental charges necessary for successful completion of work and as per directions of the Engineer-in-charge of the work
| No | 5575.5 | 5575.5 | 16.0 | False | None | None | False | None | False | 89208.0 | 0 | 3262246 | 113010 | None | CPWD 21-22 It.No 18.23.2 | Providing & fixing Flow Switch in following sizes M.S. pipe including connnection etc as required.150mm dia
| Each | 11177.02 | 11177.02 | 16.0 | False | None | None | False | None | False | 178832.32 | 0 | 3262247 | 113010 | None | V-6 P.No 90 It.No 15.96.2 | Providing, fixing, testing & commissioning ofinstallation control valve of cast iron body,brass/bronze working parts comprising of water motor alarm, bronze seat clapper, clapper arm andhydraulically driven mechanical gong bell to sound
continuous alarm when the wet riser/sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with
drain valve and bypass, test control box, ball valves, MS pipe of required size, flanges, orifice plate, gasket etc of follwing sizes as required : 150mm dia
| Each | 86730.0 | 86730.0 | 2.0 | False | None | None | False | None | False | 173460.0 | 0 | 3262248 | 113010 | None | V-6 P.No 94 It.No 15.123 | Supplying Installing, testing and commissioning of 150mm dia 4 way Fire
brigade inlet connection with Non retrn valve of 4 nos. 63 mm dia.
including cost of materials, labour, usage charges of machinery complete as
per specifications. | No | 47082.0 | 47082.0 | 1.0 | False | None | None | False | None | False | 47082.0 | 0 | 3262249 | 113010 | None | V-6 P.No 94 It.No 15.124 | Supplying Installing, testing and commissioning of 100mm dia 2 way Fire
brigade inlet connection of 2 nos. 63 mm dia. including cost of materials,
labour, usage charges of machinery complete as per specifications. | No | 40887.0 | 40887.0 | 1.0 | False | None | None | False | None | False | 40887.0 | 0 | 3262250 | 113010 | None | V-6 P.No 89 It.No 15.86 | FIRE HYDRANT SYSTEM Supplying Installing, testing and commissioning of 63mm dia single headed Gun mental Hydrant Valve with flanged inlet, stop valve,spindle and cast iron hand wheel. It has a female instantaneous outlet with Blank Cap and is Hydrostatically tested to 21 Kgf/cm2 pressure having a flow rate of 900 LPM at 7 Kgf/cm 2 of pressure with blank cap and wheel as per IS 5290 etc. complete including cost of materials, labour, usage charges of machinery complete as per specifications.
| No | 13009.5 | 13009.5 | 16.0 | False | None | None | False | None | False | 208152.0 | 0 | 3262251 | 113010 | None | V-6 P.No 89 It.no 15.88 | Supplying Installing, testing and commissioning of Reinforced Rubber Lined 2nos .RRL Fire hose of 63mm dia 15m length as per IS 8423 binded with one set of male and Female lnstantainious Gun metal coupling as per IS 903 complete including cost of materials, labour, usage charges of machinery complete as per specifications.
| Each | 6195.0 | 6195.0 | 31.0 | False | None | None | False | None | False | 192045.0 | 0 | 3262252 | 113010 | None | V-6 P.no 89 It.No 15.87 | Supplying Installing, testing and commissioning of Gun metal Branch pipe size of 63mm dia x19mm dia as per IS 903 complete including cost of materials, labour,usage charges of machinery complete as per specifications.
| Each | 5575.5 | 5575.5 | 31.0 | False | None | None | False | None | False | 172840.5 | 0 | 3262253 | 113010 | None | V6-89-15.89 | Supplying Installing, testing and commissioning of Hose cabinet made out of 18 gauge M.S.sheet with double glass door with lacing arrangement and painted with two coats of Fire red Enamel paint at outer ise of the Box and two coats of white enamel paint at inner side of the box is to accomodated 2 Nos. of Fire hose box size
20"x24"x10" complete including cost of materials, labour, usage charges of machinery complete as per specifications. | Each | 8053.5 | 8053.5 | 16.0 | False | None | None | False | None | False | 128856.0 | 0 | 3262254 | 113010 | None | V-6 P.No 89 It.No 15.9 | Supplying Installing, testing and commissioning of Hose reel cabin
| Each | 6318.9 | 6318.9 | 16.0 | False | None | None | False | None | False | 101102.4 | 0 | 3262255 | 113010 | None | V-6 P.No 90 It.No 15.92 | Supplying Installing, testing and commissioning of 19mm dia 40.0m
length hose with rubber lining smooth bore, reinforced of natural/synthetic
fibres, a rubber cover finish shall be smooth, fluted or fabric marked with
minimum thickness of 1.50mm and to with stand a working pressure of
10Kgf/sqcm confirms & tested as per IS 444/ IS 12585 including cost of
materials, labour, usage charges of machinery complete as per specifications. | Each | 6442.8 | 6442.8 | 16.0 | False | None | None | False | None | False | 103084.8 | 0 | 3262256 | 113010 | None | V-6 P.No 89 It.No 15.86 | Supplying Installing, testing and commissioning of Gun metal AIR RELEASE VALVE SIZE OF 25mm dia including cost of materials, labour, usage charges of machinery complete as per specifications. complete
| Each | 1858.5 | 1858.5 | 5.0 | False | None | None | False | None | False | 9292.5 | 0 | 3262257 | 113010 | None | V-6 P.No 94 It.No 15.125 | SITC of Gun metal BALL VALVE SIZE OF 25mm dia - etc., complete as per specificaiton with all lead and lift, loading unloading, labour, hire charges of machineries and all such incidental charges necessary for successful completion of work and as per directions of the Engineer-in-charge of the work
| No | 1486.8 | 1486.8 | 16.0 | False | None | None | False | None | False | 23788.8 | 0 | 3262258 | 113010 | None | LQR | SITC OF Fault isolation module:- Supply, Erection,Testing and Commissioning of UL-APPROVED Analog addressable fault isolator circuit modules of wall mounted type with mounting accessories. | Each | 7080.0 | 7080.0 | 48.0 | False | None | None | False | None | False | 339840.0 | 0 | 3262259 | 113010 | None | V-6 P.No 90 It.No 15.93 | Supplying Installing, testing and commissioning of approved make 15mm dia sprinkler bulb pendent/wall mounted type designed to operate 68 degrees centegrad Make Tyco/HD FIRE complete (Colour code of bulb liquid inside Glass bulb type Pendents As per IS 9972: 57COrange, 68C - Red, 79C - Yellow, 93C - Green, 141C - Blue, 182C Mauve, 227/260C - Black)
| Each | 464.63 | 464.63 | 1650.0 | False | None | None | False | None | False | 766639.5 | 0 | 3262260 | 113010 | None | ITEM 15.112 | Supplying of two bucket stand alongwith buckets. complete
| Each | 1362.9 | 1362.9 | 4.0 | False | None | None | False | None | False | 5451.6 | 0 | 3262261 | 113010 | None | V-6 P.No 94 It.no 15.122 | Stainless steel braided flexible pipe (hose) for dropping sprinklers below false ceiling, pipe shall be 16 bar pressure rating and 1500 mm long 25 mm dia with union / reducer collar, clamps etc. as required.
| Each | 3097.5 | 3097.5 | 450.0 | False | None | None | False | None | False | 1393875.0 | 0 | 3262262 | 113010 | None | V-6 P.no 94 It.No 15.120 | Supplying Installing, testing and commissioning of Ceiling Mounted powder coated Surface Finishing Mild Steel Rosette Plate including cost of materials, labour, usage charges of machinery complete as per specifications
| Each | 136.29 | 136.29 | 450.0 | False | None | None | False | None | False | 61330.5 | 0 | 3262263 | 113010 | None | VOL-2 P.No 82 It.No 11.16.2 | Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials,labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.
| Kg | 182.13 | 182.13 | 2500.0 | False | None | None | False | None | False | 455325.0 | 0 | 3262264 | 113010 | None | V-6 P.No 72 It.No 15.33 | CO2 2Kg Squeeze grip
Providing 2 Kg C02 Gas Type Fire Extinugisher Squeeze grip type, used Unused Mechanism, Squeeze Grip, Gross Weight 9.1 Kg. empty Weight 7.1 Kg. Can Height 595MM Diameter 108MM, Discharge Time less than 8 Sees, Controllable discharge
mechanism, Applicable on Class 8&C Fire, 8 Rating 88, Can Construction : Hot spinning/Forging, Valve Construction : Forging & Machining, Internal Coating of Can : Not Applicable, External coating of Can : Spray Painting, Sheet metal thickness: 4.0MM lSI Approved, 1 Year Warranty.with instalert system with Superior quality EPDM Rubber Hosepipe etc., including cost of materials, labour, usage charges of machinery complete as per specifications. complete | Each | 6814.5 | 6814.5 | 10.0 | False | None | None | False | None | False | 68145.0 | 0 | 3262265 | 113010 | None | V-6 P.No 74 It.No 15.40 | Providing Aqueous Film-Forming Foam - 9 Ltr
Providing 9 Ltr Fire Extinugisher Aqueous Film-Forming Foam Type, Stored Pressure Type, Pressure Gauge, Gross Weight 15.1Okg. empty weight 6.10kg Can Height 615 MM, Diameter 175 MM, Discharge Time less than 60 Sees, Controllable discharge mechanism (Squeeze grip with easy snap safety seal), Range minimum 6
Meters, applicable on Class A,8,CARating 13A, 8 Rating 558, Can Construction;Deep drawn & CO, Mig welded, Valve Construction: Forging & Machining, Internal Coating of Can : Epoxy Powder coating, External Coating of Can : Epoxy PoIyster
Powder coating, Sheet metal thickness: 2.0MM, lSI and EN Approved, Helium Leak Detection Tested, 1 Years Warranty with instalert system with Superior quality EPDM Rubber Hosepipe etc., including cost of materials, labour, usage charges of machinery complete as per specifications. complete | Each | 10035.9 | 10035.9 | 2.0 | False | None | None | False | None | False | 20071.8 | 0 | 3262266 | 113010 | None | V-6 P.no 62 It.No15.4 | Providing ABC Powder based MAP 50, 6Kg:-Providing 6kg Fire Extinguisher Mono Ammonium Phos phate Powder 50,
Stored Pressure Type, Pressure Gauge, Gross Weight 9.5 Kg, empty weight 3.5
Kg, Can Height 435MM, Diameter 160MM, Discharge Time less than 9 Sees,
Controllable discharge mechanism (Squeeze grip with easy snap safety seal),
Range minimum 4 meters, applicable on Class A,8,C and electrically started Fire,
A Rating 3A, 8 Rating 218, Can construction : Deep drawn & Co., Mig welded, valve Construciton : Forging and Mechining, Internal Coating of Can: Epoxy powder coating, External Coating of Can: Epoxy PoIyster power coating, Sheet metal thickness: 1.60MM, 5 years Warranty with instalert system with Superior quality EPDM Rubber Hosepipe etc., including cost of materials, labour, usage charges of machinery complete as per specifications. complete. IS 15683 Approved | Each | 3531.15 | 3531.15 | 18.0 | False | None | None | False | None | False | 63560.7 | 0 | 3262267 | 113010 | None | V-6 P.no 72 it.No 15.34 | Supply, installation in position, testing and commissioning of 4.5Kg C0 Gas Type Fire Extinugisher, Trolley Mounted, 2 Easy Weight Management used Unused Mechanism, Squeeze Grip, Gross Weight 19.1 Kg. empty Weight 14.6 Kg. Can Height 860MM Diameter 140MM, Discharge Time less than13 Sees, Controllable discharge mechanism, Applicable on Class 8&C Fire, 8 Rating 138, Can Constuctin : Hot spinning/Forging, Valve Construction : Forging & Machining, Internal Coating of Can : Not Applicable, External coating of Can : Spray Painting, Sheet metal thickness : 4.5M M lSI Approved 1Year Warranty. with instalert system with Superior quality EPDM Rubber Hosepipe etc., including cost of materials, labour, usage charges of machinery complete as per specifications. complete
| Each | 8053.5 | 8053.5 | 12.0 | False | None | None | False | None | False | 96642.0 | 0 | 3262268 | 113010 | None | PWD SR 21-22 P.No 14 It.No 15.72 | Providing and fixing in position the following type of sign boards made out of 3mm thick "Opaque" PVC foam board with computer cut, PVC non-reflective self adhesive vinyl painted foam board, complete with mirror fasteners.
Providing's Escape Singage Photoluminescent rigid plastic, 2 mm thickness, Printed on High Quality glass paint with UV resistance, 5 years warranty, Material Used - Non Radiocactive, non-phosphorous, non toxic and lead free. Available in different types & sizes, Time after removing the light source (in minutes) 60 minutes, Luminescent intensity (milicandelas * per square meter - mcd/sqm) : 30 mcd/sqm.Luminescent Intensity greater than 0.32 mcd/sqm, Period of Light Decay* (In Minutes) :3100, including cost of materials, labour, usage charges of machinery complete as per specifications.(Signage with the following text "IN CASE OF FIRE, USE STAIRS UNLESS INSTRUCTED OTHERWISE" Size:-25cm x 30 cm)
| Sq CM | 2.48 | 2.48 | 9000.0 | False | None | None | False | None | False | 22320.0 | 0 | 3262269 | 113010 | None | PWD SR -21-22 P.No 14 It.No 15.72 | Providing's Escape Singage Photoluminescent rigid plastic, 2 mm thickness, Printed on High Quality glass paint with UV resistance, 5 years warranty, Material Used - Non Radiocactive, non-phosphorous, non toxic and lead free. Available in different types & sizes, Time after removing the light source (in minutes) 60 minutes, Luminescent intensity (milicandelas * per square meter - mcd/sqm) : 30 mcd/sqm.Luminescent Intensity greater than 0.32 mcd/sqm, Period of Light Decay* (In Minutes) :3100, including cost of materials, labour, usage charges of machinery complete as per specifications.(Floor identification signage ( ie, GROUND FLOOR …etc.) at each stair enclosure on every floor, indicating the floor number in words, lettering size shall be 7.5 cm with contrasting colour from back ground.Size shall be 15cm x 60cm.)
| Sq CM | 2.48 | 2.48 | 10800.0 | False | None | None | False | None | False | 26784.0 | 0 | 3262270 | 113010 | None | V-6 P.No 92 It.No 15.106 | Providing and fixing in position the signages "FIRE ORDER" it should contain the following text on 3mm thick "Opaque" PVC foam board of computerized cut, PVC non-reflective self adhesive vinyl painted foam board of size 3' x 4'.
A) ALERT THE SECURITY AT SECURITY ROOM BY ACTUATING MANUAL CALL POINT LOCATED AT STRATEGIC LOCATIONS.
B) EVACUATE THE OCCUPANTS BY USING FIRE EXITS AND EMERGENCY EXITS ONLY AND ASSEMBLE AT VARIOUS ASSEMBLY POITS.
C) IF POSSIBLE TRY TO EXTINGUISH THE FIRE BY USING NEAREST / SUITABLE PORTABLE EXTINGUISHER OR WATER FROM NEAREST WET RISER.
D) BE CALM AND DO NOT GIVE ANY ROOM FROM PANIC, WALK, DO NOT RUN.
E) IF YOU ENCOUNTER SERIOUS DIFFICULTY IN EVACUATION, LIE DOWN FLAT AND TRY TO ATTRACT ATTENTION OF RESCUE TEAM.
| Each | 3097.5 | 3097.5 | 12.0 | False | None | None | False | None | False | 37170.0 | 0 | 3262271 | 113010 | None | PWD SR P.No 92 It.No 15.106 | ACTION BY SECURITY/RECEPTION UPON RECEIPT OF INFORMATION THROUGH FIRE ALARM OR FIRE DETECTORS OR BY USING PUBLIC ADDRESS SYSTEM.
A) ALERT THE OCCUPANTS BY USING PUBLIC ADDRESS SYSTEM.
B) INFORM FIRE CONTROL THROUGH ANY ONE OF THE FOLLOWING PHONE NUMBERS(Current phone numbers to be provided in this location by the contractor)
C) REFER EVACUATION PLAN FROM EVACUATING STANDARD PEOPLE.
D) GUIDE THE FIRE FORCE, ON THEIR ARRIVAL TO THE SEAT OF FIRE.
E) IN CASE OF THE CASUALTIES, CALL AMBULANCE BY DIALLING NUMBER: (Current phone numbers to be provided in this location by the contractor)
F) FIRE FIGHTING AGENCY
PHONE(Current phone numbers to be provided in this location by the contractor)
FAX(Current fax numbers to be provided in this location by the contractor) | Each | 3097.5 | 3097.5 | 12.0 | False | None | None | False | None | False | 37170.0 | 0 | 3262272 | 113010 | None | PWD SR 21-22 P.No 14 It.No 15.72 | Providing's Escape Singage Photoluminescent rigid plastic, 2 mm thickness, Printed on High Quality glass paint with UV resistance, 5 years warranty, Material Used - Non Radiocactive, non-phosphorous, non toxic and lead free. Available in different types & sizes, Time after removing the light source (in minutes) 60 minutes, Luminescent intensity (milicandelas * per square meter - mcd/sqm) : 30 mcd/sqm.Luminescent Intensity greater than 0.32 mcd/sqm, Period of Light Decay* (In Minutes) :3100, including cost of materials, labour, usage charges of machinery complete as per specifications.(route plan Fire Escape Route Plan A2 Size)
| Each | 2.48 | 2.48 | 18000.0 | False | None | None | False | None | False | 44640.0 | 0 | 3262273 | 113010 | None | V-6 P.No 92 It.No 15.108.3 | Supplying Installing, testing and commissioning of P.A.System console panel with push button with speaker and indictoron Accomdated in M.S.Cabinet with painting -do- 40 Zone cansole. Complete
| No | 100359.0 | 100359.0 | 1.0 | False | None | None | False | None | False | 100359.0 | 0 | 3262274 | 113010 | None | V-6 P.no 93 It.No 15.109 | P.A.System amplifier 250W RMS out put with complete wiring and controls accessable form front | No | 43674.75 | 43674.75 | 1.0 | False | None | None | False | None | False | 43674.75 | 0 | 3262275 | 113010 | None | V-6 P.No 93 It.No 15.109 | Supplying Installing, testing and commissioning of MIKE
| Each | 6814.5 | 6814.5 | 1.0 | False | None | None | False | None | False | 6814.5 | 0 | 3262276 | 113010 | None | V-6 P.No 92 It.No 15.107 | Supplying Installing, testing and commissioning of Public address system (Two way comminication type) as per requirement of Fire Force authority and which Generally comprise of Supplying Installing, testing and commissioning of Approved make 5W.wall mounted speaker with talk back facility with store enamel painted M.S.Sheet hosing etc. complete including cost of materials, labour, usage charges of machinery complete as per specifications.
| Each | 3035.55 | 3035.55 | 6.0 | False | None | None | False | None | False | 18213.3 | 0 | 3262277 | 113010 | None | CPWD-21-22 It.No 17.5.2 | Supply & Laying of 2 X 1.5 Sqmm fire alarm armored cable,600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required.
| Rmtr | 214.35 | 214.35 | 1800.0 | False | None | None | False | None | False | 385830.0 | 0 | 3262278 | 113010 | None | V-6 P.No 84 It.No 15.66 | Supply, install, test and commissioning of addressable peer to peer Networkable analogue addressable type fire alarm control panel with minimum 1500 Character /240X64 Pixel / 7inch Touchscreen graphic LCD display. The panel should be equipped with sufficient numbers of loop with 20% spare capacity, with each networkable intelligent fire alarm Control Panel having SLC with capacity of min 126/240 detectors/ devices in any combination with key pad, dual flash-based microprocessor technology, inbuilt USB Port for upload and down load the configuration tools, RS232 serial port for direct PC or modem connection, inbuilt NAC's, min 20 programmable Zonal LEDs and operates on 240V AC + 10% with 50Hz with built in charger. The panel shall have fire, fault relays, option of BMS
integration MODBUS/ BACKNET, graphical software for provision of TCP/ IP modules, Remote Access, Class 'X' wiring with provision of both class 'A' and class 'B' wiring in the SLC circuit, user friendly with communication facility to monitor & control the FACPs from a single window. The panel shall be suitable for minimum of 5000 event record facility, event fetch from FACP facility and the single panel shall be suitable for min 2000 fire zones and 200 Panels/ Nodes in one network with all other accessories required to successfully run the system. (The System cost shall be included of all necessary cards, modules, Panel enclosure, CPU and associated accessories to complete the system design). Approval: VDS/UL/EN-54 Std.2 Loop Panel
| Each | 260190.0 | 260190.0 | 3.0 | False | None | None | False | None | False | 780570.0 | 0 | 3262279 | 113010 | None | CPWD-12.2.2 | Supply, intallation, testing and Commissioning of Graphical software for entire fire alarm panels including detector configuration, commissioning etc
| Each | 236720.98 | 236720.98 | 1.0 | False | None | None | False | None | False | 236720.98 | 0 | 3262280 | 113010 | None | PWD SR 21-22 It,.No 15.66 | Supply, intallation, testing and Commissioning of loop card - etc., complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work.
| Each | 3469.2 | 3469.2 | 6.0 | False | None | None | False | None | False | 20815.2 | 0 | 3262281 | 113010 | None | V-6 P.no 84 It.No15.67 | Supply, Installation , Testing & Commissioning of Network Active Repeater Panel with 1500 Character / 240X64 Pixel / 7inch Touchscreen. The LCD shall Display all events / detectors, devices status of complete systems in the networked. Approval: UL/VDS/EN54. Make:
| Each | 80535.0 | 80535.0 | 1.0 | False | None | None | False | None | False | 80535.0 | 0 | 3262282 | 113010 | None | V-6 P.No 92 It.No 15.100 | Supply Installation testing & Commissioning of conventional type photo/Heat
electric smoke sensor with flashing LED capable of woking at 9V to 33 V DC .The
Optical Smoke Detector is unaffected by wind or atmosphericpressure and operates over the temperature range -20C to +60C. IP Rating at IP 23D & Approval with EN-54 -7, LPCB Approved. | Each | 2601.9 | 2601.9 | 900.0 | False | None | None | False | None | False | 2341710.0 | 0 | 3262283 | 113010 | None | V-6 It.No 15.103 | Supplying Installing, testing and commissioning of Response Indicator constists of twin LED wioth electronic circutarx work on 24 DC enclose in PVC retangular. complete including cost of materials, labour, HOM complete as per specifications.
| Each | 309.75 | 309.75 | 300.0 | False | None | None | False | None | False | 92925.0 | 0 | 3262284 | 113010 | None | V-6 P.No 84 It.No 15.68 | Supply, Installation, Testing & Commissioning of Analogue Addressable loop powered Sounder & Beacon with inbuilt isolator and having Min 15 distinct sound patterns/ multitone to indicate Exit doors and direct occupants for safe and fast evacuation and 100 dB output with minimum 1Hz Frequency flash rate designed for IP65 requirements and approved to operate in 10C to +55C temperature, complies with the essential requirement of the EMC Directive to be supplied with Junction Box, Glands and other mounting accessories for proper installation. (For Detectors/Device without inbuilt isolator, Fault Isolator or Isolator base to be provided with each detector/device) Approval: VDS/UL/EN54. Make: Advanced (UK),Simplex, Notifier,Argus(Uk) | Each | 6071.1 | 6071.1 | 12.0 | False | None | None | False | None | False | 72853.2 | 0 | 3262285 | 113010 | None | V-6 P.No 85 It.No 15.73 | Supplying Installing, testing and commissioning of Resettable type Manual Call point . works on 24V DC LED indicator with glass Fronted. Fire Symbol .The red Manual Call Point is approved to EN54-11 standard. MECHANICAL CONSTRUCTION The component parts of the call point are moulded in polycarbonate or ABS, depending on their function.
| Each | 3717.0 | 3717.0 | 12.0 | False | None | None | False | None | False | 44604.0 | 0 | 3262286 | 113010 | None | ELE-SR - 23-24 P.No 2 It.No 1.4.2 | Supplying and fixing sheet Metal box made out of 18 SWG
sheet metal with necessary holes for cable/conduit entry as
required with one coat of primer of approved make etc.100 x 75 x 65 mm | Each | 146.2 | 146.2 | 600.0 | False | None | None | False | None | False | 87720.0 | 0 | 3262287 | 113010 | None | PWD SR P.No 85 It.No 15.72 | Supply, install, test and commissioning of Analogue addressable Monitor Cum
Control (Input/Output) module (1+1) with inbuilt relay and isolator with LED
indicator, approved to operate in -10C to +55C temperature, complies with the essential requirement of the EMC Directive to be supplied with Junction Box, Glands and other mounting accessories for proper installation. In case of Manufacturer with single Input or Output module need to supply One quantity of each for line item.(For Detectors/Device without inbuilt isolator, Fault Isolator or Isolator base to be provided with each detector/device) Approval: EN54. | Each | 4832.1 | 4832.1 | 12.0 | False | None | None | False | None | False | 57985.2 | 0 | 3262288 | 113010 | None | PWD SR-21-22 P.No 90 It.No 15.113 | SITC of 7AM-12 V Battery for fire alarm system
| Each | 1326.97 | 1326.97 | 6.0 | False | None | None | False | None | False | 7961.82 | 0 | 3262289 | 113010 | None | PWD - 15.105 | Supply, intallation, testing and Commissioning of 2C 1.5 sq mm armoured FRLS cables in celing with suitable clamps and screws (RED colour)
| Rmtr | 185.85 | 185.85 | 6500.0 | False | None | None | False | None | False | 1208025.0 | 0 | 3262290 | 113010 | None | LQR | Supply, intallation, testing and Commissioning of Network card for fire alram panels integration | Each | 88500.0 | 88500.0 | 3.0 | False | None | None | False | None | False | 265500.0 | 0 | 3262291 | 113010 | None | LQR | Rack made out of 18 gauge M.S. Sheet with glass door with locking arrangement and powder coating grey paint two coats at inner and outer of box, is to accomodated 1 No. 250 watt amplifire, 1 No. 40 zone console and 1 no Mike and in built electronic connections circuits.Size or Rack: 0.50 m hight x 0.40 m width x 0.40 m depth - including all lead and lift charges loading and unloading charges labour charges, curing, cost& conveyance of all materials, transportation charges, all incidental charges, hire charges of all machinery and equipment required for successful completion of work etc., complete. The work shall be executed as per standard technical specification and directions of Engineer in charge of the work | Nos | 58410.0 | 58410.0 | 1.0 | False | None | None | False | None | False | 58410.0 | 0 | 3262292 | 113010 | None | LQR | Providing Water Mist 4 Kg CO2 Gas Type Fire Extinguisher, used Unused Mechanism, Squeeze Grip , Gross Weight 9.1 Kg. empty Weight 7.1 Kg. Can Height 600MM Diameter 108MM, Discharge Time less than 8 Secs, Controllable discharge mechanism, Applicable on Class B&C Fire, B Rating 13B, Can Constructing : Hot spinning/Forging, Value Construction : Forging & Machining, Internal Coating of Can : Not Applicable, External coating of Can : Spray Painting, Sheet metal thickness : 4.0MM ISI Approved, 1 Year Warranty. - With all Lead & Lifts etc., complete. as per the detailed specifications and the Directions of Engineer In charge of the work | Each | 11210.0 | 11210.0 | 12.0 | False | None | None | False | None | False | 134520.0 | 0 | 3262293 | 113010 | None | LQR | Supply, Erection, Testing & commissioning of MS Forged Tees & Collar - etc., complete as per specificaiton with all lead and lift and as per directions of the Engineer-in-charge of the work Socket Elbow 25/15 | Nos | 212.4 | 212.4 | 700.0 | False | None | None | False | None | False | 148680.0 | 0 | 3262294 | 113010 | None | LQR | Supply, Erection, Testing & commissioning of MS Forged Tees & Collar - etc., complete as per specificaiton with all lead and lift and as per directions of the Engineer-in-charge of the work
Socket Elbow 25/25
| Nos | 212.4 | 212.4 | 80.0 | False | None | None | False | None | False | 16992.0 | 0 | 3262295 | 113010 | None | LQR | Supply, Erection, Testing & commissioning of MS Forged Tees & Collar - etc., complete as per specificaiton with all lead and lift and as per directions of the Engineer-in-charge of the work
Socket Tee 25/15/25
| Nos | 295.0 | 295.0 | 120.0 | False | None | None | False | None | False | 35400.0 | 0 | 3262296 | 113010 | None | LQR | Supply, Erection, Testing & commissioning of MS Forged Tees & Collar - etc., complete as per specificaiton with all lead and lift and as per directions of the Engineer-in-charge of the work
Socket Tee 25/25/25
| Nos | 295.0 | 295.0 | 50.0 | False | None | None | False | None | False | 14750.0 | 0 | 3262297 | 113010 | None | LQR | Supply, Erection, Testing & commissioning of MS Forged Tees & Collar - etc., complete as per specificaiton with all lead and lift and as per directions of the Engineer-in-charge of the work
Socket Tee 32/15/32
| Nos | 413.0 | 413.0 | 20.0 | False | None | None | False | None | False | 8260.0 | 0 | 3262298 | 113010 | None | LQR | Supply, Erection, Testing & commissioning of MS Forged Tees & Collar - etc., complete as per specificaiton with all lead and lift and as per directions of the Engineer-in-charge of the work
Socket Tee 32/25/32
| Nos | 365.8 | 365.8 | 40.0 | False | None | None | False | None | False | 14632.0 | 0 | 3262299 | 113010 | None | LQR | Supply, Erection, Testing & commissioning of MS Forged Tees & Collar - etc., complete as per specificaiton with all lead and lift and as per directions of the Engineer-in-charge of the work
Socket Tee 40/15/40
| Nos | 531.0 | 531.0 | 50.0 | False | None | None | False | None | False | 26550.0 | 0 | 3262300 | 113010 | None | LQR | Supply, Erection, Testing & commissioning of MS Forged Tees & Collar - etc., complete as per specificaiton with all lead and lift and as per directions of the Engineer-in-charge of the work
Socket Tee 40/25/40
| Nos | 531.0 | 531.0 | 50.0 | False | None | None | False | None | False | 26550.0 | 0 | 3262301 | 113010 | None | LQR | Supply, Erection, Testing & commissioning of MS Forged Tees & Collar - etc., complete as per specificaiton with all lead and lift and as per directions of the Engineer-in-charge of the work
Forged Collar 25/15
| Nos | 129.8 | 129.8 | 1600.0 | False | None | None | False | None | False | 207680.0 | 0 | 3262302 | 113010 | None | ITEM NO 15.72 | Providing's Escape Singage Photoluminescent rigid plastic, 2 mm thickness, Printed on High Quality glass paint with UV resistance, 5 years warranty, Material Used - Non Radiocactive, non-phosphorous, non toxic and lead free. Available in different types & sizes, Time after removing the light source (in minutes) 60 minutes, Luminescent intensity (milicandelas * per square meter - mcd/sqm) : 30 mcd/sqm.Luminescent Intensity greater than 0.32 mcd/sqm, Period of Light Decay* (In Minutes) :3100, including cost of materials, labour, usage charges of machinery complete as per specifications.(signage with text FIRE EXIT,Size shall be 15cm x 60cm.) | Sq | 2.48 | 2.48 | 10800.0 | False | None | None | False | None | False | 26784.0 | 0 | 3262303 | 113010 | None | ITM 13.37 | Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing
drain pipe etc. and repairing the hole after insertion of drain pipe etc.
with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone
aggregate 20 mm nominal size), including finishing complete so as to
make it leak proof. | Nos | 387.81 | 387.81 | 100.0 | False | None | None | False | None | False | 38781.0 | 0 | 3262304 | 113010 | None | Least Quatation rate | Supplying and Erectiong of 20,000L capacity GRP tank with unloading and transportation charges etc complete in terrace. | Each | 424800.0 | 424800.0 | 2.0 | False | None | None | False | None | False | 849600.0 | 0 |
| 1718022464000 | 0 | None | None | Buildings | HVAC | 32097670.0 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3262305 | 113011 | None | PWD SR-2023-24(V 6) Ref-6.8.4 | Supplying of . TR Invertor type split Air conditioners suitable for operation on A/C supply single phase 50 Hz 230 V with hermetically sealed inverter compressor with air cooled condenser, latest R410A / R-32 refrigerant fan motor, start & run capacitors, relay & over load protector internal unit, with one indoor & one outdoor unit The condenser unit will be placed outside the room avoid noise including standard length of suitable size copper tubing covered with nitrile rubber insulation tube. suitable capacity 3 core sheathed/ PVC copper cable and a battery operated wireless remote unit.
5 star
1 Ton capacity
| No | 58923.0 | 58923.0 | 20.0 | False | None | None | False | None | False | 1178460.0 | 0 | 3262306 | 113011 | None | PWD SR-2023-24 (V 6) Ref-6.8.5 | Supplying of . TR Invertor type split Air conditioners suitable for operation on A/C supply single phase 50 Hz 230 V with hermetically sealed inverter compressor with air cooled condenser, latest R410A / R-32 refrigerant fan motor, start & run capacitors, relay & over load protector internal unit, with one indoor & one outdoor unit The condenser unit will be placed outside the room avoid noise including standard length of suitable size copper tubing covered with nitrile rubber insulation tube. suitable capacity 3 core sheathed/ PVC copper cable and a battery operated wireless remote unit.
5 star
1.5 Ton capacity
| No | 69824.0 | 69824.0 | 5.0 | False | None | None | False | None | False | 349120.0 | 0 | 3262307 | 113011 | None | PWD SR-2023-24 V6 Ref-6.8.6 | Supplying of . TR Invertor type split Air conditioners suitable for operation on A/C supply single phase 50 Hz 230 V with hermetically sealed inverter compressor with air cooled condenser, latest R410A / R-32 refrigerant fan motor, start & run capacitors, relay & over load protector internal unit, with one indoor & one outdoor unit The condenser unit will be placed outside the room avoid noise including standard length of suitable size copper tubing covered with nitrile rubber insulation tube. suitable capacity 3 core sheathed/ PVC copper cable and a battery operated wireless remote unit.
5 star
2 Ton capacity
| No | 83507.0 | 83507.0 | 17.0 | False | None | None | False | None | False | 1419619.0 | 0 | 3262308 | 113011 | None | 23-24 SR Volume-6PAGE32 ITM 6.10.1 | Supply, erection, testing, commissioning of package type Duct able type split Air-Conditioner with microprocessor control, fitted with twin scroll Compressor with R22/Latest Refrigerant. The unit shall be pre-wired to operate on 415V/50Hz AC Supply. The unit shall comprise, Evaporated condenser unit, Indoor-Outdoor Motor Fans, suitable over vent fins made up of Aluminium, Copper Refrigerant coil, Etc.,. complete and corded control unit. 3.0 TR. | No | 106314.0 | 106314.0 | 1.0 | False | None | None | False | None | False | 106314.0 | 0 | 3262309 | 113011 | None | 23-24 SR(Volume-6PAGE32 ITM (6.10.1 | Supply, erection, testing, commissioning of package type Duct able type split Air-Conditioner with microprocessor control, fitted with twin scroll Compressor with R22/Latest Refrigerant. The unit shall be pre-wired to operate on 415V/50Hz AC Supply. The unit shall comprise, Evaporated condenser unit, Indoor-Outdoor Motor Fans, suitable over vent fins made up of Aluminium, Copper Refrigerant coil, Etc.,. complete and corded control unit. 8.5 TR. | No | 201440.0 | 201440.0 | 2.0 | False | None | None | False | None | False | 402880.0 | 0 | 3262310 | 113011 | None | 23-24 SR Volume-6PAGE32ITM6.12 | Installation charges for split type air conditioner with allied works for one indoor and one outdoor unit is to be mounted on suitable angle iron support upto 3.0 Ton split/cassette type A/C. | No | 3934.0 | 3934.0 | 42.0 | False | None | None | False | None | False | 165228.0 | 0 | 3262311 | 113011 | None | 23-24 SR (Volume-6)PAGE32ITM6.13 (6.13.1) | Supplying and installation of insulated refrigerant copper tubing of 5/8" and 3/8" with polythene foam insulation 3 core 80 stand copper wiring between indoor and outdoor unit leak testing oil and gas charging for additional piping length of tube.
Split. | Rmtr | 1919.0 | 1919.0 | 170.0 | False | None | None | False | None | False | 326230.0 | 0 | 3262312 | 113011 | None | 23-24 SR (Volume-6)PAGE33ITM6.25 (6.25.1) | Supply, fabrication and installation of GI Ducting Along with flanges, supports & all fixing materials.
24 Gauge. | Sqm | 2244.0 | 2244.0 | 2000.0 | False | None | None | False | None | False | 4488000.0 | 0 | 3262313 | 113011 | None | 23-24 SR (Volume-6)PAGE33ITM6.25 (6.25.2 | Supply, fabrication and installation of GI Ducting Along with flanges, supports & all fixing materials.
22 Gauge. | Sqm | 2628.0 | 2628.0 | 300.0 | False | None | None | False | None | False | 788400.0 | 0 | 3262314 | 113011 | None | 23-24 SR (Volume-6)PAGE33ITM6.26 | Supply and installation of Thermal insulation using 13mm nitrile rubber for return air ducts.
| Sqm | 1476.0 | 1476.0 | 2000.0 | False | None | None | False | None | False | 2952000.0 | 0 | 3262315 | 113011 | None | PWD SR-2023-24 (V 6) Ref 6.27 | Supply and installation of Tarpaulin canvas between the AC
duct and AC evaporator unit including accessories. | No | 5655.0 | 5655.0 | 32.0 | False | None | None | False | None | False | 180960.0 | 0 | 3262316 | 113011 | None | PWD SR-2023-24V 6) Ref 6.29.1 | Supply and installation of Powder coated aluminium diffusers of
size 595x595mm for supply & return air.
Aluminium Diffusers
| No | 6292.0 | 6292.0 | 560.0 | False | None | None | False | None | False | 3523520.0 | 0 | 3262317 | 113011 | None | PWD SR-2023-24 (V 6) Ref 6.29.2 | Supply and installation of Powder coated aluminium diffusers of
size 595x595mm for supply & return air.
Collar Dampers
| No | 3251.0 | 3251.0 | 280.0 | False | None | None | False | None | False | 910280.0 | 0 | 3262318 | 113011 | None | PWD SR-2023-24(V 6) Ref 6.29.3 | Supply and installation of Powder coated aluminium diffusers of
size 595x595mm for supply & return air.GI Mixing Box
| No | 7775.0 | 7775.0 | 50.0 | False | None | None | False | None | False | 388750.0 | 0 | 3262319 | 113011 | None | PWD SR-2023-24 (V 6) Ref 6.29.4 | Supply and installation of Powder coated aluminium diffusers of
size 595x595mm for supply & return air.
Flexible Duct Per Mtr
| No | 2096.0 | 2096.0 | 100.0 | False | None | None | False | None | False | 209600.0 | 0 | 3262320 | 113011 | None | PWD SR-2023-24 (V 6) Ref 6.30.2 | Supply and fixing of powder coated extruded aluminium grill suitable for supply/return air including all fixing hardware
etc.,. Complete.
6" extruded aluminium grill with 15 deg to 30 deg louvers
| Rmtr | 2109.0 | 2109.0 | 50.0 | False | None | None | False | None | False | 105450.0 | 0 | 3262321 | 113011 | None | 2023-24(V 6) Ref 6.31 | Supplying & filling refrigerant latest R-410 / R-32 for Air conditioning equipment's. Which includes the labour & Nitrogen gas for pressure and leak testing. | No | 717.0 | 717.0 | 325.0 | False | None | None | False | None | False | 233025.0 | 0 | 3262322 | 113011 | None | LQR | Supply, Installation, Testing and Commissioning of Customized Double Skin Horizontal Ceiling Mounted type Air Handling Units with Thermal Break profile. (Direct Expansion (DX) refrigerant-to-air evaporator coils, as applied with condensing units with necessary KIT) Sandwitched between 0.8 precoated GI (outer skin) shall be pre coated and 0.8 Plain GI (inner skin) double skin (48 2 mm) insulated with CFC free polyurethane foam (PUF) panels of 40 Kg/cum density. AHU frame works shall be of pre cast vertical and horizontal extruded thermal break aluminium profile with three way corner frame sections. Food grade self adhesive coated neoprene gasket to be provided between panels and structure of the AHU to ensure the entire housing is airtight. DIDW centrifugal belt driven backward Aerofoil curved impeller fans (Efficiency with 75%) (AMCA Certified) to be supplied along with motor.The outlet velocity will not exceed 9.5 m/sec. Blower Make - Nicotra / Kruger. Vibration isolatator to fans and motor to avoid transmission of vibration. AHRI Certified DX Cooling coils shall be of minimum 6/8 Row deep or as per computer coil selections which ever is greater. Face Velocity across the coils should not exceed 500 FPM (2.5m/s) DX Cooling Coil should be Hydrophlic blue aluminium fines. The AHU unit shall be complete with external DX type condensing unit, complete in all respects, inclusive of complete working charge of R410a/134a Chlorofluorocarbons (CFC) environmentally free refrigerant.Drain tray for DX cooling coils shall be made of single sheet of SS 304-20G grade stainless steel sheet and should have uniform slope from all sides leading to drain connection. Drain Pan shall be insulated with 19mm thick, 55kg/cum density closed cell elastomeric insulation. Each unit filters section shall be provided with a factory assembled filter section containing washable synthetic with 50mm thick panel type PreFilter of MERV 8 (EU4)-90% down to 10 microns and FineFilter of MERV 13 (EU7) 97% down to 3 microns as per IS 7613, and ASHRAE 52.1 & ASHRAE 62.1 standards/CEN standards 13779-2007.he Motor shall be of TEFC, IP65 protected, IE3, Class 'F' insulation, suitable for 3 phase, 415 volts, 50hz power supply. Motor shall be VFD compatible and induction type. The AHU to be selected that the noise level not to exceed 60 dBA at 1.5meter distance from the AHU cabinet in all directions. Costing is inclusive of Canvas connection made of self extinguishing, moisture resistant flexible fabric to be provided between AHU outlet flange and the supply duct / plenum, copper piping, power & communication cable as specfied by manufacturer and Lifting, Shifting & Positioning with MS L angle base frame structure duly black painted with synthetic epoxy paint for all outdoor units. copper refrigerant piping with nitrile rubber insulation, UPVC drain piping and termination, valves and insulation, power wiring, control wiring and earthing, vacuum cleaneing, gas charging, pressure testing and etc.Safety interlock switch for fan operation to controle heater on/off to be provided by the AHU manufacturer. Note: Costing is inclusive of Necessary DX type condensing out door units to AHU interface Expansion Connecting Kit (PCB with EEV) & Control Control Panel with sensors, thermostat and etc., Corded Remote controller for AHU's to precisely control the flow of refrigerant for temperature control. 5.5 TR / 2,200 CFM with 50 TSP 1.5 Kw for CSU's and 1x5.5 Condensing units with necessary KIT
| No | 239540.0 | 239540.0 | 6.0 | False | None | None | False | None | False | 1437240.0 | 0 | 3262323 | 113011 | None | 23-24 SR (Volume-6)4ITM5.10 | Supplying push button operated direct online starter with anantiweld silver cadmium oxide contactor with replaceable fixed and moving contacts and bimetallic thermal overloadrelay help in anticorrosion treated sheet steel or iron clad enclosure and fixing the same to suitable capacity wires for230/440 V 1/3 phase motor upto 5 HP. | No | 2388.0 | 2388.0 | 28.0 | False | None | None | False | None | False | 66864.0 | 0 | 3262324 | 113011 | None | Market Rate | Supply, Installation, Testing and Commissioning of Customized Double Skin Horizontal Ceiling Mounted type Air Handling Units with Thermal Break profile. (Direct Expansion (DX) refrigeranttoair evaporator coils, as applied with condensing units with necessary KIT) Sandwitched between 0.8 precoated GI (outer skin) shall be pre coated and 0.8 Plain GI (inner skin) double skin (48 2 mm) insulated with CFC free polyurethane foam (PUF) panels of 40 Kg/cum density. AHU frame works shall be of pre cast vertical and horizontal extruded thermal break aluminium profile with three way corner frame sections. Food grade self adhesive coated neoprene gasket to be provided between panels and structure of the AHU to ensure the entire housing is airtight. DIDW centrifugal belt driven backward Aerofoil curved impeller fans (Efficiency with 75%) (AMCA Certified) to be supplied along with motor.The outlet velocity will not exceed 9.5 m/sec. Blower Make Nicotra / Kruger. Vibration isolatator to fans and motor to avoid transmission of vibration. AHRI Certified DX Cooling coils shall be of minimum 6/8 Row deep or as per computer coil selections which ever is greater. Face Velocity across the coils should not exceed 500 FPM (2.5m/s) DX Cooling Coil should be Hydrophlic blue aluminium fines. The AHU unit shall be complete with external DX type condensing unit, complete in all respects, inclusive of complete working charge of R410a/134a Chlorofluorocarbons (CFC) environmentally free refrigerant.Drain tray for DX cooling coils shall be made of single sheet of SS 304 20G grade stainless steel sheet and should have uniform slope from all sides leading to drain connection. Drain Pan shall be insulated with 19mm thick, 55kg/cum density closed cell elastomeric insulation. Each unit filters section shall be provided with a factory assembled filter section containing washable synthetic with 50mm thick panel type PreFilter of MERV 8 (EU4)- 90% down to 10 microns and FineFilter of MERV 13 (EU7) 97% down to 3 microns as per IS 7613, and ASHRAE 52.1 & ASHRAE 62.1 standards/CEN standards 13779-2007.he Motor shall be of TEFC, IP-65 protected, IE-3, Class 'F' insulation, suitable for 3 phase, 415 volts, 50hz power supply. Motor shall be VFD compatible and induction type. The AHU to be selected that the noise level not to exceed 60 dBA at 1.5meter distance from the AHU cabinet in all directions. Costing is inclusive of Canvas connection made of self extinguishing, moisture resistant flexible fabric to be provided between AHU outlet flange and the supply duct / plenum, copper piping, power & communication cable as specfied by manufacturer and Lifting, Shifting & Positioning with MS L angle base frame structure duly black painted with synthetic epoxy paint for all outdoor units. copper refrigerant piping with nitrile rubber insulation, UPVC drain piping and termination, valves and insulation, power wiring, control wiring and earthing, vacuum cleaneing, gas charging, pressure testing and etc.Safety interlock switch for fan operation to controle heater on/off to be provided by the AHU manufacturer. Note: Costing is inclusive of Necessary DX type condensing out door units to AHU interface Expansion Connecting Kit (PCB with EEV) & Control Control Panel with sensors, thermostat and etc., Corded Remote controller for AHU's to precisely control the flow of refrigerant for temperature control. 8.5 TR / 3,400 CFM with 50 TSP 2.2 Kw for CSU's and 1x11.0 Condensing units with necessary KIT. | No | 332760.0 | 332760.0 | 16.0 | False | None | None | False | None | False | 5324160.0 | 0 | 3262325 | 113011 | None | Market Rate | Supply, Installation, Testing and Commissioning of Double Skin Horizontal Ceiling/Floor Mounted Cabinet type Fresh air Units Sandwitched between 0.6 precoated GI (outer skin) shall be pre coated and 0.6 Plain GI (inner skin) double skin (23+/-2 mm) insulated with CFC free polyurethane foam (PUF) panels of 40 Kg/cum density. with DIDW centrifugal belt driven backward curved Aerofoil impeller fans (Efficiency with 75%) (AMCA Certified) to be supplied along with motor. Vibration isolatator to fans and motor to avoid transmission of vibration, Motor, Pulleys, Belts & Belt guard, Pre-Filter of MERV 8 (EU-4)- 90% down to 10 microns. Drive sets, base frame, spring mounts, Limit switches, Marine lamp, Inspection door and all necessary accessories.Blower Make - Nicotra / Kruger.
The unit shall be suitable for outdoor application with necessary weather hood, canopy and supports with necessary MS channels & threaded rods.
The Motor shall be of TEFC, IP-55 protected, IE-3, Class 'F' insulation, suitable for 3 phase, 415 volts, 50hz power supply.
Motor shall be VFD compatible and induction type. VFD starter panel cost quantified separately (Cost excluded for the same).Costing is inclusive of Factory fabricated non-cloth type Fire retardant flexible connection made of high quality self extinguishing, moisture resistant flexible fabric with matching angle flanges between Fresh air units outlet flange and the connected plenum or ducts.
1,000 CFM / 40 mm TSP / 1.1 kW | No | 37760.0 | 37760.0 | 1.0 | False | None | None | False | None | False | 37760.0 | 0 | 3262326 | 113011 | None | LQR | Supply, Installation, Testing & Commissioning of Rectangular / Circular inline fan with variable speed regulator with suitable for installing in any position in vertical or horizontal ducts. All accessories like fan, motor, flanges, non-canvass type fire retardant flexible connections, etc., The impeller shall be of forward type. The motor should be of IP21, class 'B' insulation suitable for operating at 1phase, 230V, 50hz power supply.
Note : Rectangular / Circular inline fan shall have low sound level exceeding not more than 40 dBA at 1 meter distance.
Note: Costing is inclusive of Factory fabricated non-cloth type Fire retardant flexible connection made of high quality self extinguishing, moisture resistant flexible fabric with matching angle flanges between Fresh/Exhaut air units outlet flange and the connected plenum or ducts.
300 CFM / 20mm TSP. | No | 12390.0 | 12390.0 | 1.0 | False | None | None | False | None | False | 12390.0 | 0 | 3262327 | 113011 | None | LQR | Supply, Installation, Testing & Commissioning of Rectangular / Circular inline fan with variable speed regulator with suitable for installing in any position in vertical or horizontal ducts. All accessories like fan, motor, flanges, non-canvass type fire retardant flexible connections, etc., The impeller shall be of forward type. The motor should be of IP21, class 'B' insulation suitable for operating at 1phase, 230V, 50hz power supply.
Note : Rectangular / Circular inline fan shall have low sound level exceeding not more than 40 dBA at 1 meter distance.
Note: Costing is inclusive of Factory fabricated non-cloth type Fire retardant flexible connection made of high quality self extinguishing, moisture resistant flexible fabric with matching angle flanges between Fresh/Exhaut air units outlet flange and the connected plenum or ducts.
500 CFM / 20mm TSP. | No | 15930.0 | 15930.0 | 1.0 | False | None | None | False | None | False | 15930.0 | 0 | 3262328 | 113011 | None | Market rate | Supply, installation, testing and commissioning of Interconnecting Soft drawn / Hard drawn Refrigerant copper Piping with insulation with UV protection coating.
Note:
a) To protect Nitrile rubber insulation of outdoor installed copper piping from degradation due to ultra violet rays and atmospheric condition.
b) UV protection coating on existing copper pipes (with insulation) shall be done with the help of starbond and 7mm cloth etc. UV protection coating shall be done on all the pipes irrespective of size of pipes
work duly insulated with 13mm & 19mm thick elastomeric nitrile rubber type tubular insulation between VRV/VRF/DX Type indoor & outdoor units.
Note :
c) Costing is inclusive of necessary supports & supporting rods, saddles at 1m interval.
d) Refrigerant copper Piping quantity (Rmt) to be estimated before finalization of order or receipt of work order as per the drawing and take necessary amendment if any variation in the quantity.
e) Actual measurement of Refrigerant copper Piping quantity (Rmt) should be taken as per site condition only.
1/4"" (6.35 mm) X 21 Swg (0.8 mm) - Soft drawn (Insulation = 13mm thick)
| Rmtr | 1180.0 | 1180.0 | 250.0 | False | None | None | False | None | False | 295000.0 | 0 | 3262329 | 113011 | None | LQR | Supply, installation, testing and commissioning of Interconnecting Soft drawn / Hard drawn Refrigerant copper Piping with insulation with UV protection coating.
Note:
a) To protect Nitrile rubber insulation of outdoor installed copper piping from degradation due to ultra violet rays and atmospheric condition.
b) UV protection coating on existing copper pipes (with insulation) shall be done with the help of starbond and 7mm cloth etc. UV protection coating shall be done on all the pipes irrespective of size of pipes
work duly insulated with 13mm & 19mm thick elastomeric nitrile rubber type tubular insulation between VRV/VRF/DX Type indoor & outdoor units.
Note :
c) Costing is inclusive of necessary supports & supporting rods, saddles at 1m interval.
d) Refrigerant copper Piping quantity (Rmt) to be estimated before finalization of order or receipt of work order as per the drawing and take necessary amendment if any variation in the quantity.
e) Actual measurement of Refrigerant copper Piping quantity (Rmt) should be taken as per site condition only.
3/8" (9.52 mm) X 21 Swg (0.8mm) - Soft drawn (Insulation = 13mm thick)
| Rmtr | 1298.0 | 1298.0 | 215.0 | False | None | None | False | None | False | 279070.0 | 0 | 3262330 | 113011 | None | Market Rate | Supply, installation, testing and commissioning of Interconnecting Soft drawn / Hard drawn Refrigerant copper Piping with insulation with UV protection coating.
Note:
a) To protect Nitrile rubber insulation of outdoor installed copper piping from degradation due to ultra violet rays and atmospheric condition.
b) UV protection coating on existing copper pipes (with insulation) shall be done with the help of starbond and 7mm cloth etc. UV protection coating shall be done on all the pipes irrespective of size of pipes
work duly insulated with 13mm & 19mm thick elastomeric nitrile rubber type tubular insulation between VRV/VRF/DX Type indoor & outdoor units.
Note :
c) Costing is inclusive of necessary supports & supporting rods, saddles at 1m interval.
d) Refrigerant copper Piping quantity (Rmt) to be estimated before finalization of order or receipt of work order as per the drawing and take necessary amendment if any variation in the quantity.
e) Actual measurement of Refrigerant copper Piping quantity (Rmt) should be taken as per site condition only.
1/2" (12.7 mm) X 21 Swg (0.8 mm) - Soft drawn (Insulation = 13mm thick)
| Rmtr | 1416.0 | 1416.0 | 440.0 | False | None | None | False | None | False | 623040.0 | 0 | 3262331 | 113011 | None | LQR | Supply, installation, testing and commissioning of Interconnecting Soft drawn / Hard drawn Refrigerant copper Piping with insulation with UV protection coating.
Note:
a) To protect Nitrile rubber insulation of outdoor installed copper piping from degradation due to ultra violet rays and atmospheric condition.
b) UV protection coating on existing copper pipes (with insulation) shall be done with the help of starbond and 7mm cloth etc. UV protection coating shall be done on all the pipes irrespective of size of pipes work duly insulated with 13mm & 19mm thick elastomeric nitrile rubber type tubular insulation between VRV/VRF/DX Type indoor & outdoor units.
Note :
a) Costing is inclusive of necessary supports & supporting rods, saddles at 1m interval.
b) Refrigerant copper Piping quantity (Rmt) to be estimated before finalization of order or receipt of work order as per the drawing and take necessary amendment if any variation in the quantity.
c) Actual measurement of Refrigerant copper Piping quantity (Rmt) should be taken as per site condition only.
5/8" (15.9 mm) X 19 Swg (1 mm) - Soft drawn (Insulation = 13mm thick)
| Sqm | 1593.0 | 1593.0 | 15.0 | False | None | None | False | None | False | 23895.0 | 0 | 3262332 | 113011 | None | LQR | Supply, installation, testing and commissioning of Interconnecting Soft drawn / Hard drawn Refrigerant copper Piping with insulation with UV protection coating.
Note:
a) To protect Nitrile rubber insulation of outdoor installed copper piping from degradation due to ultra violet rays and atmospheric condition.
b) UV protection coating on existing copper pipes (with insulation) shall be done with the help of starbond and 7mm cloth etc. UV protection coating shall be done on all the pipes irrespective of size of pipes work duly insulated with 13mm & 19mm thick elastomeric nitrile rubber type tubular insulation between VRV/VRF/DX Type indoor & outdoor units.
Note :
a) Costing is inclusive of necessary supports & supporting rods, saddles at 1m interval.
b) Refrigerant copper Piping quantity (Rmt) to be estimated before finalization of order or receipt of work order as per the drawing and take necessary amendment if any variation in the quantity.
c) Actual measurement of Refrigerant copper Piping quantity (Rmt) should be taken as per site condition only.
3/4" (19.05 mm) X 19 Swg (1 mm) - Hard drawn (Insulation = 13mm thick) | Rmtr | 1711.0 | 1711.0 | 10.0 | False | None | None | False | None | False | 17110.0 | 0 | 3262333 | 113011 | None | LQR | Supply, installation, testing and commissioning of Interconnecting Soft drawn / Hard drawn Refrigerant copper Piping with insulation with UV protection coating.
Note:
a) To protect Nitrile rubber insulation of outdoor installed copper piping from degradation due to ultra violet rays and atmospheric condition.
b) UV protection coating on existing copper pipes (with insulation) shall be done with the help of starbond and 7mm cloth etc. UV protection coating shall be done on all the pipes irrespective of size of pipes work duly insulated with 13mm & 19mm thick elastomeric nitrile rubber type tubular insulation between VRV/VRF/DX Type indoor & outdoor units.
Note :
a) Costing is inclusive of necessary supports & supporting rods, saddles at 1m interval.
b) Refrigerant copper Piping quantity (Rmt) to be estimated before finalization of order or receipt of work order as per the drawing and take necessary amendment if any variation in the quantity.
c) Actual measurement of Refrigerant copper Piping quantity (Rmt) should be taken as per site condition only.
7/8" ( 22.2 mm) X 19 Swg (1 mm) - Hard drawn (Insulation = 19mm thick)
| Rmtr | 1829.0 | 1829.0 | 120.0 | False | None | None | False | None | False | 219480.0 | 0 | 3262334 | 113011 | None | LQR | Supply, installation, testing and commissioning of Interconnecting Soft drawn / Hard drawn Refrigerant copper Piping with insulation with UV protection coating.
Note:
a) To protect Nitrile rubber insulation of outdoor installed copper piping from degradation due to ultra violet rays and atmospheric condition.
b) UV protection coating on existing copper pipes (with insulation) shall be done with the help of starbond and 7mm cloth etc. UV protection coating shall be done on all the pipes irrespective of size of pipes work duly insulated with 13mm & 19mm thick elastomeric nitrile rubber type tubular insulation between VRV/VRF/DX Type indoor & outdoor units.
Note :
a) Costing is inclusive of necessary supports & supporting rods, saddles at 1m interval.
b) Refrigerant copper Piping quantity (Rmt) to be estimated before finalization of order or receipt of work order as per the drawing and take necessary amendment if any variation in the quantity.
c) Actual measurement of Refrigerant copper Piping quantity (Rmt) should be taken as per site condition only.
1.0" (25.4 mm) X 19 Swg (1 mm) - Hard drawn (Insulation = 19mm thick) | Rmtr | 1947.0 | 1947.0 | 10.0 | False | None | None | False | None | False | 19470.0 | 0 | 3262335 | 113011 | None | LQR | Supply, Installation, Testing & Commissioning of Back draft damper (BDD). The Back draft damper with the outer shell constructed of 1.6mm thick galvanized steel frame and the blade/Leaf with 1mm thick aluminum and with necessary flanges for connection and as per specifications.
(Area calculation : (L x B)
| Sqm | 10620.0 | 10620.0 | 1.0 | False | None | None | False | None | False | 10620.0 | 0 | 3262336 | 113011 | None | LQR | Supply, Installation, Testing & Commissioning of Butterfly Damper GI Constructed Single Flap with round flange on one side and 10mm grove on other side for fixing of flexible duct with the help of band.
20G GI constructed self lubricated bronze Bushes and 1.6mm flange.
250 dia
| No | 2360.0 | 2360.0 | 40.0 | False | None | None | False | None | False | 94400.0 | 0 | 3262337 | 113011 | None | LQR | Supply, Installation, Testing & Commissioning of Extruded Aluminum powder coated Exhaust air Disc valves/grille without volume control dampers for Pantry. a) Note: Colour shall be as per the False ceiling or Architect intent.
150 mm Dia
| No | 1475.0 | 1475.0 | 40.0 | False | None | None | False | None | False | 59000.0 | 0 | 3262338 | 113011 | None | LQR | Supply, installation, testing and commissioning of Extruded Al. Powder coated Fresh air / Exhaust air louvers with slimline blade (3 mm nominal thickness) grille height 16 mm, blade pitch 12.5 mm and blade angle 0/15 degree deflection without damper and with end flanges.
Note: Colour shall be as per the False ceiling or Architect intent. | Sqm | 10620.0 | 10620.0 | 3.0 | False | None | None | False | None | False | 31860.0 | 0 | 3262339 | 113011 | None | Market rate | Supply, Installation, Testing and Commissioning of Aluminium Collar Damper of opposed blade type aluminum extruded construction black anodized dampers. (Used in supplay air)
| Sqm | 7670.0 | 7670.0 | 3.0 | False | None | None | False | None | False | 23010.0 | 0 | 3262340 | 113011 | None | Market Rate | Supply, Installation, Testing & Commissioning of Condensate CPVC drain piping with insulated with 6mm Nitrile rubber insulation including elbows, connectors, U traps, Y-connections and flexible tubing for all indoor units to the nearest drain points / toilet drain / pantry drain / HVAC shaft available as per approved shop drawings or site conditions and as per directions of the Consultant and Architect.
The quote should inclusive of all Hardware necessary to secure the pipes.
40 mm dia | Rmtr | 590.0 | 590.0 | 225.0 | False | None | None | False | None | False | 132750.0 | 0 | 3262341 | 113011 | None | Market Rate | Supply, Installation, Testing & Commissioning of Condensate CPVC drain piping with insulated with 6mm Nitrile rubber insulation including elbows, connectors, U traps, Y-connections and flexible tubing for all indoor units to the nearest drain points / toilet drain / pantry drain / HVAC shaft available as per approved shop drawings or site conditions and as per directions of the Consultant and Architect.
The quote should inclusive of all Hardware necessary to secure the pipes.
32 mm dia | Rmtr | 531.0 | 531.0 | 225.0 | False | None | None | False | None | False | 119475.0 | 0 | 3262342 | 113011 | None | LQR | Supply, Installation, Testing & Commissioning of Condensate CPVC drain piping with insulated with 6mm Nitrile rubber insulation including elbows, connectors, U traps, Y-connections and flexible tubing for all indoor units to the nearest drain points / toilet drain / pantry drain / HVAC shaft available as per approved shop drawings or site conditions and as per directions of the Consultant and Architect.
The quote should inclusive of all Hardware necessary to secure the pipes.
25 mm dia | Rmtr | 413.0 | 413.0 | 400.0 | False | None | None | False | None | False | 165200.0 | 0 | 3262343 | 113011 | None | LQR | Supply, Installation, Testing & Commissioning of Drain Pumps for CHW/VRV/VRF/DX Type Hi-Wall Units and Ceiling Mounted Units.
Mini Blanc Pumps (External) for Hi-Wall units. (Max. flow 12L/h & Head is 10Met) | No | 8850.0 | 8850.0 | 42.0 | False | None | None | False | None | False | 371700.0 | 0 | 3262344 | 113011 | None | Market Rate | Supply, Installation, Testing & Commissioning of Drain Pumps for CHW/VRV/VRF/DX Type Hi-Wall Units and Ceiling Mounted Units.
Mini Tank Pump (Less then 5.0 TR CSU/FCU) - (Max. flow 35L/h & Head is 15Met)
| No | 10620.0 | 10620.0 | 1.0 | False | None | None | False | None | False | 10620.0 | 0 | 3262345 | 113011 | None | LQR | Supply, Installation, Testing & Commissioning of Drain Pumps for CHW/VRV/VRF/DX Type Hi-Wall Units and Ceiling Mounted Units.
Max Hi-Flow (Above 5.0 TR CSU/FCU) - (Max. flow 550L/h & Head is 5Met)
| No | 12980.0 | 12980.0 | 24.0 | False | None | None | False | None | False | 311520.0 | 0 | 3262346 | 113011 | None | LQR | Supply, Installation, Testing & Commissioning of Duct type Strip heater (For Customized AHU's) with nessacery electrical wiring and connection. Incoming power supply from respactive Starter panel. (Used in Winter season to achiev the room Temp)
Heater bank & Duct befer and after the Heater bank should be panted in RED for 150mm on either side of the Heater bank.
1.5 Kw | No | 8260.0 | 8260.0 | 20.0 | False | None | None | False | None | False | 165200.0 | 0 | 3262347 | 113011 | None | LQR | Supply, Installation, Testing & Commissioning of Duct type Strip heater (For Customized AHU's) with nessacery electrical wiring and connection. Incoming power supply from respactive Starter panel. (Used in Winter season to achiev the room Temp)
Heater bank & Duct befer and after the Heater bank should be panted in RED for 150mm on either side of the Heater bank.
3 Kw | No | 11800.0 | 11800.0 | 15.0 | False | None | None | False | None | False | 177000.0 | 0 | 3262348 | 113011 | None | Market rate | Supply, Installation, Testing & Commissioning of Magnehelic Differential Pressure Gages (IP-67 enclosure) to Indicate Positive, Negative or Differential, Accurate within 1%. Note: Pressures must be less than 35 psi.
Mounting Orientation:Diaphragm in vertical position. Consult factory for other position orientations.
Costing is inclusive of with necessary fittings and Pitot Tube and etc.
AHU/CSU Filter Section
| No | 11210.0 | 11210.0 | 22.0 | False | None | None | False | None | False | 246620.0 | 0 | 3262349 | 113011 | None | LQR | Supply, Installation, Testing & Commissioning of Duct Type Temperature & RH Sensors (IP-40 enclosure) (Immersion depth : 230 mm) with all mounting accessories to measure the Return Air temperatures.
(Temperature range : -0C to 55C & R.H. range 10% to 90%)
Note : Used for AHU's, CSU's FCU's & Cassette units. | No | 10030.0 | 10030.0 | 22.0 | False | None | None | False | None | False | 220660.0 | 0 | 3262350 | 113011 | None | LQR | Supply, Installation, Testing & Commissioning of Room Type Temperature & RH Digital Sensors (Thermostats) with all mounting accessories to measure the critical Room air temperatures.
(Temperature range : -20C to 60C & R.H. range 0% to 99%)
| No | 10030.0 | 10030.0 | 22.0 | False | None | None | False | None | False | 220660.0 | 0 | 3262351 | 113011 | None | LQR | Supply, installation, testing and commissioning of Electrical Power & Controle cabling for AC units, Ventilation & Pressurization fans units.
Note :
a) Costing is inclusive of necessary supports & supporting rods, saddles at 1m interval.
b) Electrical Power cabling quantity (Rmt) to be estimated before finalization of order or receipt of work order as per the drawing and take necessary amendment if any variation in the quantity.
c) Actual measurement of Electrical Power cabling quantity (Rmt) should be taken as per site condition only.
3.0 Core x 2.5 Sqmm - For AHU/CSU/Ventilation units units.
(Can be used up to 3.7 Kw / 3Phase)
Flexible Cross-linked polyethylene (XLPE) insulated Armoured copper cables (FRLS) Control & Power cable to connect HVAC or Electrical starter panel to respective HVAC equipment.
| Rmtr | 472.0 | 472.0 | 350.0 | False | None | None | False | None | False | 165200.0 | 0 | 3262352 | 113011 | None | LQR | Supply, installation, testing and commissioning of Interconnecting Soft drawn / Hard drawn Refrigerant copper Piping with insulation with UV protection coating.
Note:
a) To protect Nitrile rubber insulation of outdoor installed copper piping from degradation due to ultra violet rays and atmospheric condition.
b) UV protection coating on existing copper pipes (with insulation) shall be done with the help of starbond and 7mm cloth etc. UV protection coating shall be done on all the pipes irrespective of size of pipes work duly insulated with 13mm & 19mm thick elastomeric nitrile rubber type tubular insulation between VRV/VRF/DX Type indoor & outdoor units.
Note :
a) Costing is inclusive of necessary supports & supporting rods, saddles at 1m interval.
b) Refrigerant copper Piping quantity (Rmt) to be estimated before finalization of order or receipt of work order as per the drawing and take necessary amendment if any variation in the quantity.
c) Actual measurement of Refrigerant copper Piping quantity (Rmt) should be taken as per site condition only.
1 1/8" (28.6 mm) X 19 Swg (1 mm) - Hard drawn (Insulation = 19mm thick) | Rmtr | 2065.0 | 2065.0 | 270.0 | False | None | None | False | None | False | 557550.0 | 0 | 3262353 | 113011 | None | LQR | Supply, installation, testing and commissioning of Interconnecting Soft drawn / Hard drawn Refrigerant copper Piping with insulation with UV protection coating.
Note:
a) To protect Nitrile rubber insulation of outdoor installed copper piping from degradation due to ultra violet rays and atmospheric condition.
b) UV protection coating on existing copper pipes (with insulation) shall be done with the help of starbond and 7mm cloth etc. UV protection coating shall be done on all the pipes irrespective of size of pipes work duly insulated with 13mm & 19mm thick elastomeric nitrile rubber type tubular insulation between VRV/VRF/DX Type indoor & outdoor units.
Note :
a) Costing is inclusive of necessary supports & supporting rods, saddles at 1m interval.
b) Refrigerant copper Piping quantity (Rmt) to be estimated before finalization of order or receipt of work order as per the drawing and take necessary amendment if any variation in the quantity.
c) Actual measurement of Refrigerant copper Piping quantity (Rmt) should be taken as per site condition only.
1 1/4" (31.8 mm) X 18.5 Swg (1.1 mm) - Hard drawn (Insulation = 19mm thick) | No | 2242.0 | 2242.0 | 10.0 | False | None | None | False | None | False | 22420.0 | 0 | 3262354 | 113011 | None | LQR | upply, installation, testing and commissioning of Interconnecting Soft drawn / Hard drawn Refrigerant copper Piping with insulation with UV protection coating.
Note:
a) To protect Nitrile rubber insulation of outdoor installed copper piping from degradation due to ultra violet rays and atmospheric condition.
b) UV protection coating on existing copper pipes (with insulation) shall be done with the help of starbond and 7mm cloth etc. UV protection coating shall be done on all the pipes irrespective of size of pipes work duly insulated with 13mm & 19mm thick elastomeric nitrile rubber type tubular insulation between VRV/VRF/DX Type indoor & outdoor units.
Note :
a) Costing is inclusive of necessary supports & supporting rods, saddles at 1m interval.
b) Refrigerant copper Piping quantity (Rmt) to be estimated before finalization of order or receipt of work order as per the drawing and take necessary amendment if any variation in the quantity.
c) Actual measurement of Refrigerant copper Piping quantity (Rmt) should be taken as per site condition only.
1 3/8" (34.9 mm) X 18 Swg (1.2 mm) - Hard drawn (Insulation = 19mm thick) | No | 2360.0 | 2360.0 | 10.0 | False | None | None | False | None | False | 23600.0 | 0 | 3262355 | 113011 | None | LQR | Supply, Installation, Testing & Commissioning of Galvanized duct-Class VIII with zinc coating of 120 gm / Sqmt surface area as per IS-277. With TDF/TDC Flange system with factory fabricated Box section with neoprene rubber gaskets of thickness to match the dimensions of the ducts shall be used for connecting two ducts.Duct construction and installation shall be in accordance with SMACNA codes and Standards and all ducts testing pressure should be 500 Pascal. (pa).All ducting shall be of factory fabricated completely finished and transported to site in a boxed form (including the duct flange and the VAV transition pieces, grille / slot / diffusers plenum boxes, Z pieces and etc.)
The Duct shall be supported with GI steel Rods & MS angle Supports at regular minimum 2500mm intervals.
Ducts should be factory fabricated & Transportation should be in box section only to site. in site the duct needs to be stored in proper manner & covered with polythene sheets to avoid dust accumulation.
G.I. Sheet Make - Tata / Sail / Jindal / Vizag Steel.
Ducts sizes from and above 1200mm width should have Tie rods placed as per the standards with gasket and sealant to avoid the duct Bulging and Bulge out. These ducting quintettes are including of slot / diffusers plenum boxes with necessary threaded rods for supporting & anchor fasten. Vendor need to consider while quoting.All accessories like sealant, vanes, flanges, suspension rods , anchor bolts, GI bolts & nuts, canvas connections & splitter dampers etc.,. Costing is inclusive of MS angle Supports at regular intervals, threaded rod supports, angle flanges, anchor fastners, hot dipped galvanized bolts & nuts. Scaffolding arrangements to install the ducts and air terminals etc., Costing is inclusive of Scaffolding arrangements to install the ducts and air terminals.Costing is inclusive of Opening and closing for all the duct entries in civil / gypsum / any type of partition shall be under scope of HVAC vendor. Duct routing diagram can be checked in drawing prior for quoting.ressure testing of sheet metal ducts with necessary components like semi-rigid flexible ducts, fans and the measuring kit. Pressure testing shall be carried out for complete air distribution system excluding flexible ducts, diffuser box, diffusers and grilles. Pressure testing shall be carried out prior to thermal insulation and as per SMACNA standards and approval shall be obtained from PMC and consultants.
20 Gauge (1.00mm Thick - 1201mm - 2100mm) | Sqm | 1829.0 | 1829.0 | 20.0 | False | None | None | False | None | False | 36580.0 | 0 | 3262356 | 113011 | None | LQR | Supply, Installation, Testing & Commissioning of Open cell "Class-1" Nitrile rubber Insulation for Duct Acoustics insulation with Ultrafresh Antimicrobial protection as per ASTM G21, ASTM G22, UL-181 and E2180 , Density 140 80Kg / m3, UL94 approved (HBF, HF 1 & HF 2) in accordance to UL 94,1996. Thermal conductivity 0.047 W / MK at 20 Deg C, Air Erosion Resistance test Confirming to ASTM Standard C 1071 05 (section 12.7).
Moisture resistant-joining tapes of 2 inches width with self adhesive to be supplied with the insulation material by the supplier.
Use Low Voc Adhesive. (Adhesive VOC level as per LEED requirement)
Note if the adhesive is not self adhiesive type then the glue should be used with the same manufacturer.
15mm Thick | Sqm | 1297.0 | 1297.0 | 400.0 | False | None | None | False | None | False | 518800.0 | 0 | 3262357 | 113011 | None | LQR | Supply, Installation, Testing & Commissioning of Closed cell "Class-O" Nitrile rubber Insulation with Factroy Laminated Alu-foil with Ultrafresh Antimicrobial protection with both side skin/smooth surface, As per ASTM G21, ASTM G22, UL-181 and E2180. Class “O” IMO A 653 (16), FM Global, UL 94 & EPA approved,with Density 40-60kg / m3. Temperature of -50 to 116 Deg C and As per EN12667(DIN 52612). Thermal conductivity of 0.036 W / m K @ 0 deg C. Water vapour permeability as per EN12086 (DIN 52615) , Moisture Resistance Factor = 7000. Aluminum foil tape of 75mm width should be used to seal the joints with self adhesive tape (Black Cotton Tape not acceptable).
Use Low Voc Adhesive. (Adhesive VOC level as per LEED requirement)
Material shall be FM approved and preferred color shall be Black.
Note if the adhesive is not self adhiesive type then the glue should be used with the same manufacturer.
Note: Costing is inclusive of necessary support like cup and washer with scaffolding arrangements to install the underdeck insulation.
25mm Thick (Under Deck Insulation) | Sqm | 1062.0 | 1062.0 | 1000.0 | False | None | None | False | None | False | 1062000.0 | 0 | 3262358 | 113011 | None | LQR | Supply, Installation, Testing & Commissioning of Factory fabricated powder coated Double skin plenum. Outer skin constructed with not less than 0.63mm thick GI sheet and the inner sheet shall be of not less than 0.63mm GI plain sheet., with 25mm thick sandwiched RPUF (CFC free) insulation of density not less than 40kg/mAnd with necessary High grade Extruded Aluminum cross supports for rigidity and cutouts for duct & AHU connections.
Note:
a) The Plenum shall be provided with as Access Door. (Size are not less then 800mmx600mm)
b) These plenum is inside the AHU Rooms should be supported with special acoustic hangers to avoid transmission of vibaration from AHU Room to adjacent sensitive areas.
c) Color of the Plenum should match the color of AHU & CSU installed at site | Sqm | 5900.0 | 5900.0 | 50.0 | False | None | None | False | None | False | 295000.0 | 0 | 3262359 | 113011 | None | LQR | Supply, Installation, Testing & Commissioning of Fire damper with opposed blade (Fusible link type). Fire damper as per UL 555, outer shell constructed with 1.6mm thick galvanized steel frame and the blade/Leaf with 1.6mm thick GSS and with necessary flanges for connection. The damper shall be of 90 min fire rating with Fusible Link & spring mechanism the damper shall be held open by a replaceable fusible link rated at 74 deg C.
(Area calculation : (L x B | Sqm | 15340.0 | 15340.0 | 12.0 | False | None | None | False | None | False | 184080.0 | 0 | 3262360 | 113011 | None | LQR | Supply, Installation, Testing & Commissioning of Quadrant type Volume controle Damper (VCD). The volume control damper shall be of low leakage type with the outer shell constructed of 1.6mm thick galvanized steel frame and the blade/Leaf with 1.6mm thick GSS and with necessary flanges for connection etc.,
(Area calculation : (L x B) | Sqm | 9440.0 | 9440.0 | 17.0 | False | None | None | False | None | False | 160480.0 | 0 | 3262361 | 113011 | None | LQR | Supply, Installation, Testing and Commissioning of Double Skin Horizontal Ceiling/Floor Mounted Cabinet type Fresh air Units Sandwitched between 0.6 precoated GI (outer skin) shall be pre coated and 0.6 Plain GI (inner skin) double skin (23 2 mm) insulated with CFC free polyurethane foam (PUF) panels of 40 Kg/cum density. with DIDW centrifugal belt driven backward curved Aerofoil impeller fans (Efficiency with 75) (AMCA Certified) to be supplied along with motor. Vibration isolatator to fans and motor to avoid transmission of vibration, Motor, Pulleys, Belts & Belt guard, Preilter of MERV 8 (EU4)90down to 10 microns. Drive sets, base frame, spring mounts, Limit switches, Marine lamp, Inspection door and all necessary accessories.Blower Make - Nicotra / Kruger.
The unit shall be suitable for outdoor application with necessary weather hood, canopy and supports with necessary MS channels & threaded rods.
The Motor shall be of TEFC, IP-55 protected, IE-3, Class 'F' insulation, suitable for 3 phase, 415 volts, 50hz power supply.
Motor shall be VFD compatible and induction type. VFD starter panel cost quantified separately (Cost excluded for the same).Costing is inclusive of Factory fabricated non-cloth type Fire retardant flexible connection made of high quality self extinguishing, moisture resistant flexible fabric with matching angle flanges between Fresh air units outlet flange and the connected plenum or ducts.
2,500 CFM / 40 mm TSP / 1.5 kW | Nos | 88500.0 | 88500.0 | 2.0 | False | None | None | False | None | False | 177000.0 | 0 | 3262362 | 113011 | None | LQR | Supply, Installation, Testing & Commissioning of Rectangular / Circular inline fan with variable speed regulator with suitable for installing in any position in vertical or horizontal ducts. All accessories like fan, motor, flanges, non-canvass type fire retardant flexible connections, etc., The impeller shall be of forward type. The motor should be of IP21, class 'B' insulation suitable for operating at 1phase, 230V, 50hz power supply.
Note : Rectangular / Circular inline fan shall have low sound level exceeding not more than 40 dBA at 1 meter distance.
Note: Costing is inclusive of Factory fabricated non-cloth type Fire retardant flexible connection made of high quality self extinguishing, moisture resistant flexible fabric with matching angle flanges between Fresh/Exhaut air units outlet flange and the connected plenum or ducts.
150 CFM / 20mm TSP. | Nos | 10620.0 | 10620.0 | 1.0 | False | None | None | False | None | False | 10620.0 | 0 | 3262363 | 113011 | None | LQR | Supply, Installation, Testing and Commissioning of Double Skin Horizontal Ceiling/Floor Mounted Cabinet type Fresh air Units Sandwitched between 0.6 precoated GI (outer skin) shall be pre coated and 0.6 Plain GI (inner skin) double skin (23 2 mm) insulated with CFC free polyurethane foam (PUF) panels of 40 Kg/cum density. with DIDW centrifugal belt driven backward curved Aerofoil impeller fans (Efficiency with 75%) (AMCA Certified) to be supplied along with motor. Vibration isolatator to fans and motor to avoid transmission of vibration, Motor, Pulleys, Belts & Belt guard, Pre-Filter of MERV 8 (EU-4)- 90% down to 10 microns. Drive sets, base frame, spring mounts, Limit switches, Marine lamp, Inspection door and all necessary accessories.Blower Make - Nicotra / Kruger.
The unit shall be suitable for outdoor application with necessary weather hood, canopy and supports with necessary MS channels & threaded rods.
The Motor shall be of TEFC, IP-55 protected, IE-3, Class 'F' insulation, suitable for 3 phase, 415 volts, 50hz power supply.
Motor shall be VFD compatible and induction type. VFD starter panel cost quantified separately (Cost excluded for the same).Costing is inclusive of Factory fabricated non-cloth type Fire retardant flexible connection made of high quality self extinguishing, moisture resistant flexible fabric with matching angle flanges between Fresh air units outlet flange and the connected plenum or ducts.
3,000 CFM / 40 mm TSP / 1.5 kW | Nos | 106200.0 | 106200.0 | 4.0 | False | None | None | False | None | False | 424800.0 | 0 |
| 1718022464000 | 0 | None | None | Buildings | Internal Water Supply & Sanitary works | 11742725.59 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3262364 | 113012 | None | V-2 P.No 131 It.No 14.2.1 | Providing and fixing white vitreous china pedestal type water closet
(European type W.C. pan) with seat and lid, 10 litre low level white
P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fix- tures complete, including cutting and making good the walls and floors wherever required: W.C. pan with ISI marked white solid plastic seat and lid | No | 5994.28 | 5994.28 | 23.0 | False | None | None | False | None | False | 137868.44 | 0 | 3262365 | 113012 | None | V-2 P.No 136 It.No 14.34.1 | Providing and fixing toilet paper holder :
| No | 753.31 | 753.31 | 23.0 | False | None | None | False | None | False | 17326.13 | 0 | 3262366 | 113012 | None | V-2 P.No 132 It.No 14.7.1 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15mm C.P. brass pillar taps
| No | 4200.21 | 4200.21 | 28.0 | False | None | None | False | None | False | 117605.88 | 0 | 3262367 | 113012 | None | V-2 P.No 137 It.No 14.37 | Providing and fixing PTMT Bottle Trap for Wash basin and sink.
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require
| No | 379.13 | 379.13 | 28.0 | False | None | None | False | None | False | 10615.64 | 0 | 3262368 | 113012 | None | V-2 P.No A-16 It.No 166 | C.P. Brass stop cock (concealed) 15 mm
GF Toilet
| No | 650.47 | 650.47 | 33.0 | False | None | None | False | None | False | 21465.51 | 0 | 3262369 | 113012 | None | V-2 P.No 136 It.No 14.28.1.2 | Providing and fixing P.V.C. waste pipe for sink or wash basin including
P.V.C. waste fittings complete.
| No | 113.98 | 113.98 | 33.0 | False | None | None | False | None | False | 3761.34 | 0 | 3262370 | 113012 | None | V-2 P.No 118 It.No 13.8.2.2 | Providing and fixing unplasticised PVC connection pipe with brass
unions :
15 mm nominal bore
| No | 130.09 | 130.09 | 33.0 | False | None | None | False | None | False | 4292.97 | 0 | 3262371 | 113012 | None | V-2 P.No 137 It.No 14.40.2 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g.
| Nos | 581.09 | 581.09 | 28.0 | False | None | None | False | None | False | 16270.52 | 0 | 3262372 | 113012 | None | V-2 P.No 136 It.No 14.31 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
| No | 1511.58 | 1511.58 | 28.0 | False | None | None | False | None | False | 42324.24 | 0 | 3262373 | 113012 | None | V-2 P.No 137 It.No 14.38 | Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms.
| No | 179.65 | 179.65 | 28.0 | False | None | None | False | None | False | 5030.2 | 0 | 3262374 | 113012 | None | V-2 P.No 132 It.No 14.4.4 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : Range of four urinal basins with 10 litre white P.V.C. automatic flushing cistern
| No | 16193.7 | 16193.7 | 4.0 | False | None | None | False | None | False | 64774.8 | 0 | 3262375 | 113012 | None | V-2 P.No 117 It.NO 13.2.1 | Providing and fixing brass bib cock of approved quality :15 mm nominal bore
| No | 354.35 | 354.35 | 5.0 | False | None | None | False | None | False | 1771.75 | 0 | 3262376 | 113012 | None | V-2 P.no 114 It.No 14.83 a | Providing and fixing Robe hook twin made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete - Class
Economy
| No | 678.92 | 678.92 | 23.0 | False | None | None | False | None | False | 15615.16 | 0 | 3262377 | 113012 | None | V-2 P.No 128 It.No 13.63 | Providing and fixing PVC (S.W.R) Multi Floor Trap 10.0 cm X 7.5 cm X 5.0 cm X 4.0 cm with all fitting arrangements & all necessary accessories complete
| No | 302.31 | 302.31 | 35.0 | False | None | None | False | None | False | 10580.85 | 0 | 3262378 | 113012 | None | V-5 P.No 113 It.No 10.1.3 | Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for:
50mm nominal bore pipes, From Sink & Urinal lines
| Rmtr | 247.18 | 247.18 | 95.0 | False | None | None | False | None | False | 23482.1 | 0 | 3262379 | 113012 | None | V-5 P.No 113 It.No 10.1.5 | Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for:
PVC pipes 75mm dia., 6 kg/sqcm & class 3 | Rmtr | 604.94 | 604.94 | 140.0 | False | None | None | False | None | False | 84691.6 | 0 | 3262380 | 113012 | None | V-5 P.No 113 It.No 10.1.7 | Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for:
PVC pipes 110mm dia., 6 kg/sqcm & class 3
| Rmtr | 1174.76 | 1174.76 | 155.0 | False | None | None | False | None | False | 182087.8 | 0 | 3262381 | 113012 | None | V-5 P.No 121 It.No 10.15.3 | Lowering, laying true to line and level of PVC Ringtite / PVC Pipes and cuts of pipes wherever necessary including jointing of pipes and specials with jointing of approved type, with all labour with encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS and commissioning (Contractor will make his own arrangements for procuring water for testing) etc. for: 50mm
| Rmtr | 49.56 | 49.56 | 95.0 | False | None | None | False | None | False | 4708.2 | 0 | 3262382 | 113012 | None | V-5 P.no 121 It.No10.15.5 | Lowering, laying true to line and level of PVC Ringtite / PVC Pipes and cuts of pipes wherever necessary including jointing of pipes and specials with jointing of approved type, with all labour with encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS and commissioning (Contractor will make his own arrangements for procuring water for testing) etc. for:
75mm
| Rmtr | 94.16 | 94.16 | 140.0 | False | None | None | False | None | False | 13182.4 | 0 | 3262383 | 113012 | None | V-5 P.No 121 It.No 10.15.7 | Lowering, laying true to line and level of PVC Ringtite / PVC Pipes and cuts of pipes wherever necessary including jointing of pipes and specials with jointing of approved type, with all labour with encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS and commissioning (Contractor will make his own arrangements for procuring water for testing) etc. for:
110mm
| Rmtr | 138.76 | 138.76 | 155.0 | False | None | None | False | None | False | 21507.8 | 0 | 3262384 | 113012 | None | PWD V-2 P.No 122 It.No 13.32.2 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.
20 mm nominal dia Pipes
| Rmtr | 469.58 | 469.58 | 310.0 | False | None | None | False | None | False | 145569.8 | 0 | 3262385 | 113012 | None | PWD V-2 P.No 122 It.No 13.31.3 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.
25 mm nominal dia Pipes
| Rmtr | 591.0 | 591.0 | 65.0 | False | None | None | False | None | False | 38415.0 | 0 | 3262386 | 113012 | None | V-5 P.No 133 It.No 11.5.2 | Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark.For 20 mm dia GM (Copper alloy) Gate valves
| No | 1100.23 | 1100.23 | 31.0 | False | None | None | False | None | False | 34107.13 | 0 | 3262387 | 113012 | None | V-5 P.no 133 It.No11.5.3 | Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark
For 25 mm dia GM (Copper alloy) Gate valves
| No | 1448.39 | 1448.39 | 4.0 | False | None | None | False | None | False | 5793.56 | 0 | 3262388 | 113012 | None | V-2 P.No 131 It.No 14.2.1 | Providing and fixing white vitreous china pedestal type water closet
(European type W.C. pan) with seat and lid, 10 litre low level white
P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fix-tures complete, including cutting and making good the walls and floors wherever required: W.C. pan with ISI marked white solid plastic seat and lid
| No | 6054.22 | 6054.22 | 30.0 | False | None | None | False | None | False | 181626.6 | 0 | 3262389 | 113012 | None | V-2 P.No 136 It.No 14.34.1 | Providing and fixing toilet paper holder :
| No | 760.84 | 760.84 | 30.0 | False | None | None | False | None | False | 22825.2 | 0 | 3262390 | 113012 | None | V-2 P.No 132 It.no 14.7.1 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15mm C.P. brass pillar taps
| No | 4242.21 | 4242.21 | 31.0 | False | None | None | False | None | False | 131508.51 | 0 | 3262391 | 113012 | None | V-2 P.No 137 It.No 14.37.1 | Providing and fixing PTMT Bottle Trap for Wash basin and sink.
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:
| No | 382.92 | 382.92 | 51.0 | False | None | None | False | None | False | 19528.92 | 0 | 3262392 | 113012 | None | V-2 P.no A-16 It.No 166 | C.P. Brass stop cock (concealed) 15 mm
| No | 656.98 | 656.98 | 52.0 | False | None | None | False | None | False | 34162.96 | 0 | 3262393 | 113012 | None | V-2 P.No 136 It.No 14.28.1.2 | Providing and fixing P.V.C. waste pipe for sink or wash basin including
P.V.C. waste fittings complete.
| No | 115.12 | 115.12 | 52.0 | False | None | None | False | None | False | 5986.24 | 0 | 3262394 | 113012 | None | V-2 P.No 118 It.No 13.8.2.2 | Providing and fixing unplasticised PVC connection pipe with brass
unions :
15 mm nominal bore
| No | 131.39 | 131.39 | 52.0 | False | None | None | False | None | False | 6832.28 | 0 | 3262395 | 113012 | None | V-2 P.No 137 It.No 14.40.2 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g.
| No | 586.9 | 586.9 | 31.0 | False | None | None | False | None | False | 18193.9 | 0 | 3262396 | 113012 | None | V-2 P.No 136 It.No 14.31 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
| No | 1526.7 | 1526.7 | 32.0 | False | None | None | False | None | False | 48854.4 | 0 | 3262397 | 113012 | None | V-2 P.No 137 It.No 14.38 | Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms.
| No | 181.45 | 181.45 | 71.0 | False | None | None | False | None | False | 12882.95 | 0 | 3262398 | 113012 | None | V-2 P.No 117 It.No 13.2.1 | Providing and fixing brass bib cock of approved quality :15 mm nominal bore
| No | 357.89 | 357.89 | 5.0 | False | None | None | False | None | False | 1789.45 | 0 | 3262399 | 113012 | None | V-2 P.No 134 It.No 14.11.2 | Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : Size 600x450x200 mm
| No | 6359.56 | 6359.56 | 17.0 | False | None | None | False | None | False | 108112.52 | 0 | 3262400 | 113012 | None | V-2 P.No 114 It.No 14.83 a | Providing and fixing Robe hook twin made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete - Class
Economy
| No | 685.76 | 685.76 | 30.0 | False | None | None | False | None | False | 20572.8 | 0 | 3262401 | 113012 | None | V-2 P.No 128 It.No 13.63 | Providing and fixing PVC (S.W.R) Multi Floor Trap 10.0 cm X 7.5 cm X 5.0 cm X 4.0 cm with all fitting arrangements & all necessary accessories complete
| No | 305.33 | 305.33 | 71.0 | False | None | None | False | None | False | 21678.43 | 0 | 3262402 | 113012 | None | V-5 P.No 113 It.No 10.1.3 | Providing and installing at site of work P.V.C. pipes including cost of pipes and specials and labour, including lowering into trenches, laying true to line, level and perfect linking at joints leak proof including jointing of approved type with all labour charges and all lift charges, handling charges including encasing the pipe around to a depth not less than 15 cms with gravel or selected earth available from the excavation etc. complete.50mm nominal bore pipes, From Sink & Urinal lines
| Rmtr | 249.65 | 249.65 | 55.0 | False | None | None | False | None | False | 13730.75 | 0 | 3262403 | 113012 | None | V-5 P.No 113 It.No 10.1.5 | Providing and installing at site of work P.V.C. pipes including cost of pipes and specials and labour, including lowering into trenches, laying true to line, level and perfect linking at joints leak proof including jointing of approved type with all labour charges and all lift charges, handling charges including encasing the pipe around to a depth not less than 15 cms with gravel or selected earth available from the excavation etc. complete.
PVC pipes 75mm dia., 6 kg/sqcm & class 3
| Rmtr | 610.99 | 610.99 | 235.0 | False | None | None | False | None | False | 143582.65 | 0 | 3262404 | 113012 | None | V-5 P.No 113 It.No 10.1.7 | Providing and installing at site of work P.V.C. pipes including cost of pipes and specials and labour, including lowering into trenches, laying true to line, level and perfect linking at joints leak proof including jointing of approved type with all labour charges and all lift charges, handling charges including encasing the pipe around to a depth not less than 15 cms with gravel or selected earth available from the excavation etc. complete.
PVC pipes 110mm dia., 6 kg/sqcm & class 3
| Rmtr | 1186.51 | 1186.51 | 220.0 | False | None | None | False | None | False | 261032.2 | 0 | 3262405 | 113012 | None | V-5 P.No 121 It.No 10.15.3 | Lowering, laying true to line and level of PVC Ringtite / PVC Pipes and cuts of pipes wherever necessary including jointing of pipes and specials with jointing of approved type, with all labour with encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS and commissioning (Contractor will make his own arrangements for procuring water for testing) etc. for:
50mm | Rmtr | 50.05 | 50.05 | 55.0 | False | None | None | False | None | False | 2752.75 | 0 | 3262406 | 113012 | None | V-5 P.No 121 It.no 10.15.5 | Lowering, laying true to line and level of PVC Ringtite / PVC Pipes and cuts of pipes wherever necessary including jointing of pipes and specials with jointing of approved type, with all labour with encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS and commissioning (Contractor will make his own arrangements for procuring water for testing) etc. for:
75mm
| Rmtr | 95.1 | 95.1 | 235.0 | False | None | None | False | None | False | 22348.5 | 0 | 3262407 | 113012 | None | V-5 P.No 121 It.No 10.15.7 | Lowering, laying true to line and level of PVC Ringtite / PVC Pipes and cuts of pipes wherever necessary including jointing of pipes and specials with jointing of approved type, with all labour with encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS and commissioning (Contractor will make his own arrangements for procuring water for testing) etc. for:
110mm
| Rmtr | 140.15 | 140.15 | 220.0 | False | None | None | False | None | False | 30833.0 | 0 | 3262408 | 113012 | None | PWD V-2 P.No 122 It.No 13.32.2 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.20 mm nominal dia Pipes
| Rmtr | 474.27 | 474.27 | 660.0 | False | None | None | False | None | False | 313018.2 | 0 | 3262409 | 113012 | None | PWD V-2 P.No 122 It.No 13.31.3 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge
25 mm nominal dia Pipes
| Rmtr | 596.91 | 596.91 | 175.0 | False | None | None | False | None | False | 104459.25 | 0 | 3262410 | 113012 | None | V-5 P.No 133 It.No 11.5.2 | Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark.For 20 mm dia GM (Copper alloy) Gate valves
| No | 1111.23 | 1111.23 | 35.0 | False | None | None | False | None | False | 38893.05 | 0 | 3262411 | 113012 | None | V-5 P.No 133 It.No 11.5.3 | Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark
For 25 mm dia GM (Copper alloy) Gate valves
| No | 1462.87 | 1462.87 | 8.0 | False | None | None | False | None | False | 11702.96 | 0 | 3262412 | 113012 | None | V-5 P.No 133 It.No 11.15.4 | Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark.For 32 mm dia GM (Copper alloy) Gate valves | No | 1674.36 | 1674.36 | 3.0 | False | None | None | False | None | False | 5023.08 | 0 | 3262413 | 113012 | None | PWD V-2 P.No 122 It.No 13.3 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.32 mm nominal dia Pipes
| Rmtr | 697.02 | 697.02 | 45.0 | False | None | None | False | None | False | 31365.9 | 0 | 3262414 | 113012 | None | V-2 P.No 132 It.No 14.4.4 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : Range of four urinal basins with 10 litre white P.V.C. automatic flushing cistern
| No | 16355.7 | 16355.7 | 14.0 | False | None | None | False | None | False | 228979.8 | 0 | 3262415 | 113012 | None | V-2 P.No 133 It.No14.10.b | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required :
510x1040 mm bowl depth 250 mm
| No | 7030.31 | 7030.31 | 4.0 | False | None | None | False | None | False | 28121.24 | 0 | 3262416 | 113012 | None | V-2 P.No 140 It.No 14.62.b | Providing and fixing Sink cock with swivel spout & wall flange, wall mountable made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete - Class
Premium
| No | 3611.51 | 3611.51 | 4.0 | False | None | None | False | None | False | 14446.04 | 0 | 3262417 | 113012 | None | V-2 P.No 128 It.No 13.63.b | Providing and fixing Stainless Steel Grab Bar 600 mm Long with all concealed fitting arrangements & all necessary accesories complete - Class
Premium
| No | 10210.1 | 10210.1 | 2.0 | False | None | None | False | None | False | 20420.2 | 0 | 3262418 | 113012 | None | V-2 P.No 140 It.No 14.6.b | Providing and fixing Single lever wall mixer with L shaped Tubular bend set for overhead shower made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete - Class
Premium
| No | 10570.5 | 10570.5 | 20.0 | False | None | None | False | None | False | 211410.0 | 0 | 3262419 | 113012 | None | V-2 P.No 143 It.No 14.81b | Providing and fixing Overhead rain showers of minimum dimension 225x225mm & wall flange made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete - Class
Premium
| No | 7439.51 | 7439.51 | 20.0 | False | None | None | False | None | False | 148790.2 | 0 | 3262420 | 113012 | None | V-2 P.No 140 It.No 14.57b | Providing and fixing Wall spout with wall flange made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete - Class
Premium
| No | 2980.81 | 2980.81 | 20.0 | False | None | None | False | None | False | 59616.2 | 0 | 3262421 | 113012 | None | V-2 P.No128 It.No 13.63.b | Providing and fixing Stainless Steel Grab Bar 600 mm Long with all concealed fitting arrangements & all necessary accesories complete - Class
Premium
| No | 10109.0 | 10109.0 | 2.0 | False | None | None | False | None | False | 20218.0 | 0 | 3262422 | 113012 | None | V-2 P.No 131 It.No 14.2.1 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fix- tures complete, including cutting and making good the walls and floors wherever required: W.C. pan with ISI marked white solid plastic seat and lid
| No | 6114.17 | 6114.17 | 32.0 | False | None | None | False | None | False | 195653.44 | 0 | 3262423 | 113012 | None | V-2 P.No136 It.No 14.34.1 | Providing and fixing toilet paper holder :
| No | 768.38 | 768.38 | 32.0 | False | None | None | False | None | False | 24588.16 | 0 | 3262424 | 113012 | None | V-2 P.No 132 It.No 14.7.1 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15mm C.P. brass pillar taps
| No | 4282.21 | 4282.21 | 24.0 | False | None | None | False | None | False | 102773.04 | 0 | 3262425 | 113012 | None | V-2 P.No 137 It.No 14.37.1 | Providing and fixing PTMT Bottle Trap for Wash basin and sink.
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:
| No | 386.72 | 386.72 | 41.0 | False | None | None | False | None | False | 15855.52 | 0 | 3262426 | 113012 | None | V-2 P.No A-16 It.No 166 | C.P. Brass stop cock (concealed) 15 mm
| No | 663.48 | 663.48 | 41.0 | False | None | None | False | None | False | 27202.68 | 0 | 3262427 | 113012 | None | V-2 P.No 136 It.No 14.28.1.2 | Providing and fixing P.V.C. waste pipe for sink or wash basin including
P.V.C. waste fittings complete. | No | 116.27 | 116.27 | 41.0 | False | None | None | False | None | False | 4767.07 | 0 | 3262428 | 113012 | None | V-2 P.No 118 It.No 13.8.2.2 | Providing and fixing unplasticised PVC connection pipe with brass
unions :15 mm nominal bore
| No | 132.7 | 132.7 | 41.0 | False | None | None | False | None | False | 5440.7 | 0 | 3262429 | 113012 | None | V-2 P.No 137 It.No 14.40.2 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g.
| No | 592.71 | 592.71 | 41.0 | False | None | None | False | None | False | 24301.11 | 0 | 3262430 | 113012 | None | V-2 P.No 136 It.No 14.31 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
| No | 1541.81 | 1541.81 | 24.0 | False | None | None | False | None | False | 37003.44 | 0 | 3262431 | 113012 | None | V-2 P.No 137 It.No 14.38 | Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms.
| No | 183.25 | 183.25 | 72.0 | False | None | None | False | None | False | 13194.0 | 0 | 3262432 | 113012 | None | V-2 P.No117 It.No 13.2.1 | Providing and fixing brass bib cock of approved quality :15 mm nominal bore | No | 361.44 | 361.44 | 5.0 | False | None | None | False | None | False | 1807.2 | 0 | 3262433 | 113012 | None | V-2 P.No 134 It.No 14.11.2 | Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : Size 600x450x200 mm
| No | 6422.53 | 6422.53 | 13.0 | False | None | None | False | None | False | 83492.89 | 0 | 3262434 | 113012 | None | V-2 P.No 133 It.No 14.10.1.1 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required :510x1040 mm bowl depth 250 mm
| No | 7099.92 | 7099.92 | 4.0 | False | None | None | False | None | False | 28399.68 | 0 | 3262435 | 113012 | None | V-2 P.No 140 It.no 14.62 b | Providing and fixing Sink cock with swivel spout & wall flange, wall mountable made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete - ClassPremium
| No | 3647.27 | 3647.27 | 4.0 | False | None | None | False | None | False | 14589.08 | 0 | 3262436 | 113012 | None | V-2 P.No 114 It.No 14.83 a | Providing and fixing Robe hook twin made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete - Class
Economy
| No | 692.55 | 692.55 | 32.0 | False | None | None | False | None | False | 22161.6 | 0 | 3262437 | 113012 | None | V-2 P.No 128 It.No 13.63 | Providing and fixing PVC (S.W.R) Multi Floor Trap 10.0 cm X 7.5 cm X 5.0 cm X 4.0 cm with all fitting arrangements & all necessary accessories complete
| No | 308.36 | 308.36 | 63.0 | False | None | None | False | None | False | 19426.68 | 0 | 3262438 | 113012 | None | V-2 P.No 128 It.No 13.63 b | Providing and fixing Stainless Steel Grab Bar 600 mm Long with all concealed fitting arrangements & all necessary accesories complete - Class
Premium
| No | 10311.18 | 10311.18 | 2.0 | False | None | None | False | None | False | 20622.36 | 0 | 3262439 | 113012 | None | V-2 P.No 140 It.No 14.6 b | Providing and fixing Single lever wall mixer with L shaped Tubular bend set for overhead shower made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete - Class Premium
| No | 10675.15 | 10675.15 | 14.0 | False | None | None | False | None | False | 149452.1 | 0 | 3262440 | 113012 | None | V-2 P.No 143 It.No 14.81 b | Providing and fixing Overhead rain showers of minimum dimension 225x225mm & wall flange made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete - Class
Premium
| No | 7513.17 | 7513.17 | 14.0 | False | None | None | False | None | False | 105184.38 | 0 | 3262441 | 113012 | None | V-2 P.No 140 It.No 14.57 b | Providing and fixing Wall spout with wall flange made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete - Class
Premium
| No | 3010.32 | 3010.32 | 14.0 | False | None | None | False | None | False | 42144.48 | 0 | 3262442 | 113012 | None | V-5 P.No 113 It.No 10.1.3 | Providing and installing at site of work P.V.C. pipes including cost of pipes and specials and labour, including lowering into trenches, laying true to line, level and perfect linking at joints leak proof including jointing of approved type with all labour charges and all lift charges, handling charges including encasing the pipe around to a depth not less than 15 cms with gravel or selected earth available from the excavation etc. complete.
50mm nominal bore pipes, From Sink & Urinal lines
| Rmtr | 252.12 | 252.12 | 55.0 | False | None | None | False | None | False | 13866.6 | 0 | 3262443 | 113012 | None | V-5 P.No 113 It.No 10.1.5 | Providing and installing at site of work P.V.C. pipes including cost of pipes and specials and labour, including lowering into trenches, laying true to line, level and perfect linking at joints leak proof including jointing of approved type with all labour charges and all lift charges, handling charges including encasing the pipe around to a depth not less than 15 cms with gravel or selected earth available from the excavation etc. complete.PVC pipes 75mm dia., 6 kg/sqcm & class 3
| Rmtr | 617.04 | 617.04 | 245.0 | False | None | None | False | None | False | 151174.8 | 0 | 3262444 | 113012 | None | V-5 P.No 113 It.No 10.1.7 | Providing and installing at site of work P.V.C. pipes including cost of pipes and specials and labour, including lowering into trenches, laying true to line, level and perfect linking at joints leak proof including jointing of approved type with all labour charges and all lift charges, handling charges including encasing the pipe around to a depth not less than 15 cms with gravel or selected earth available from the excavation etc. complete.PVC pipes 110mm dia., 6 kg/sqcm & class 3
| Rmtr | 1198.25 | 1198.25 | 255.0 | False | None | None | False | None | False | 305553.75 | 0 | 3262445 | 113012 | None | V-5 P.No 121 It.No 10.15 | Lowering, laying true to line and level of PVC Ringtite / PVC Pipes and cuts of pipes wherever necessary including jointing of pipes and specials with jointing of approved type, with all labour with encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS and commissioning (Contractor will make his own arrangements for procuring water for testing) etc. for:
50mm
| Rmtr | 50.55 | 50.55 | 55.0 | False | None | None | False | None | False | 2780.25 | 0 | 3262446 | 113012 | None | V-5 P.No 121 It.No 10.15 | Lowering, laying true to line and level of PVC Ringtite / PVC Pipes and cuts of pipes wherever necessary including jointing of pipes and specials with jointing of approved type, with all labour with encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS and commissioning (Contractor will make his own arrangements for procuring water for testing) etc. for:75mm
| Rmtr | 96.05 | 96.05 | 245.0 | False | None | None | False | None | False | 23532.25 | 0 | 3262447 | 113012 | None | V-5 P.No 121 It.No 10.15.7 | Lowering, laying true to line and level of PVC Ringtite / PVC Pipes and cuts of pipes wherever necessary including jointing of pipes and specials with jointing of approved type, with all labour with encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS and commissioning (Contractor will make his own arrangements for procuring water for testing) etc. for:110mm
| Rmtr | 141.54 | 141.54 | 255.0 | False | None | None | False | None | False | 36092.7 | 0 | 3262448 | 113012 | None | PWD V-2 P.No122 It.No 13.32.2 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.
20 mm nominal dia Pipes
| Rmtr | 478.97 | 478.97 | 430.0 | False | None | None | False | None | False | 205957.1 | 0 | 3262449 | 113012 | None | PWD V-2 P.No 122 It.No13.31.3 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.
25 mm nominal dia Pipes
| Rmtr | 602.82 | 602.82 | 150.0 | False | None | None | False | None | False | 90423.0 | 0 | 3262450 | 113012 | None | PWD V-2 P.No 122 It.No 13.31.4 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.32 mm nominal dia Pipes
| Rmtr | 703.93 | 703.93 | 10.0 | False | None | None | False | None | False | 7039.3 | 0 | 3262451 | 113012 | None | V-5 P.No 133 It.No 11.15.2 | Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark.For 20 mm dia GM (Copper alloy) Gate valves
| No | 1122.24 | 1122.24 | 32.0 | False | None | None | False | None | False | 35911.68 | 0 | 3262452 | 113012 | None | V-5 P.No 133 It.No 11.15.3 | Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark.
For 25 mm dia GM (Copper alloy) Gate valves
| No | 1477.36 | 1477.36 | 6.0 | False | None | None | False | None | False | 8864.16 | 0 | 3262453 | 113012 | None | V-5 P.No 133 It.No 11.15.4 | Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark.
For 32 mm dia GM (Copper alloy) Gate valves
| No | 1690.94 | 1690.94 | 1.0 | False | None | None | False | None | False | 1690.94 | 0 | 3262454 | 113012 | None | Market Rate | Supplying, fixing, testing and commissioning of CP health faucet Hand operated spray unit (instant type) CP Crutch etc., complete as directed by the Engineer in charge. ALD-577. ( Jaguar make or Equalent ).
| No | 2301.0 | 2301.0 | 145.0 | False | None | None | False | None | False | 333645.0 | 0 | 3262455 | 113012 | None | Market Rate | Supplying, installing, testing and commissioning approved make Submersible Pump made of C.I Construction suitable for building application. Thequoted rate shall also include for auto lvl.controller with cabling between hePumps, control panel, UGR & OHT etc.,. complete.approx. Length of cable = 80. providing necessary safety devices viz. dry run protection, over load relays etc., complete working on 230V, 50Hz, 1Ph, with starter,.(1 no. working and 1no. Standby ) Sump To OHT (DOMESTIC) (7.5.0 HP x 02 Nos) - 01 Working and 01 Stand by pumps. | No | 135700.0 | 135700.0 | 3.0 | False | None | None | False | None | False | 407100.0 | 0 | 3262456 | 113012 | None | Market Rate | Supplying, installing, testing and commissioning approved make Submersible Pump made of C.I Construction suitable for building application. Thequoted rate shall also include for auto lvl.controller with cabling between hePumps, control panel, UGR & OHT etc.,. complete.approx. Length of cable = 80. providing necessary safety devices viz. dry run protection, over load relays etc., complete working on 230V, 50Hz, 1Ph, with starter,.(1 no. working and 1no. Standby ) Sump To OHT (Flushing water)(5HP x 02 Nos) - 01 Working and 01 Stand by pumps.
Discharge of Pump Lps 2.4
Discharge pressure m 48
Number of pumps: Nos. 2
Working pumps Nos. 1
Stand by pumps Nos. 1
| No | 100890.0 | 100890.0 | 2.0 | False | None | None | False | None | False | 201780.0 | 0 | 3262457 | 113012 | None | Market Rate | Making openings of the following diameters RCC beams/slab using core cutters having diamond edged core bits and redoing the same after fixing of pipes with PVC rings / grouting with non-shrink grouts etc., complete including ensuring water tightness of the system.
| No | 1003.0 | 1003.0 | 58.0 | False | None | None | False | None | False | 58174.0 | 0 | 3262458 | 113012 | None | Market Rate | Packing the core openings in slabs & beams by providing PVC pipes and filling the void after fixing the pipe by packing with polymer concrete or non shrink grout etc,. Complete ensuring water tightness in the joint.The core cut area of the slab shall be prepared rough also same treatment on the puddle pipe to be made to ensure proper bonding.
| No | 1121.0 | 1121.0 | 78.0 | False | None | None | False | None | False | 87438.0 | 0 | 3262459 | 113012 | None | Market Rate | Supplying, fixing, testing and commissioning of portable Water Cooler (Floor mounted model) in corridors for drinking water with all the necessary accessories etc.
| No | 21240.0 | 21240.0 | 10.0 | False | None | None | False | None | False | 212400.0 | 0 | 3262460 | 113012 | None | Market Rate | Supplying and fixing in position solid block masonry pedestals of approaximate size 400x230x230mm with brackets and G.I clamps for laying pipes on terrace. etc,. complete as directed by the Engineer in charge.
| No | 708.0 | 708.0 | 220.0 | False | None | None | False | None | False | 155760.0 | 0 | 3262461 | 113012 | None | Market Rate | Supply and fixing of GM ball cock with copper float(High pressure float) of approved brand of manufacture and fixed on to the inlet pipe at the underground sump tank & OHT.
50 mm dia
| No | 4159.5 | 4159.5 | 1.0 | False | None | None | False | None | False | 4159.5 | 0 | 3262462 | 113012 | None | Market Rate | MS sheet metal brackets
Note: The length of the bracket shall be equal to the sum of the outer diameters of all pipe and 50mm for working space per pipe of size 15 to 75mm and 100mm for working space per pipe for pipes of size 75mm and above diameters.
| Kg | 165.2 | 165.2 | 635.0 | False | None | None | False | None | False | 104902.0 | 0 | 3262463 | 113012 | None | Market Rate | Rain harvest pit of size 1200 mm dia and 6 m deep is proposed to be constructed. The rain water harvest pit consists of 300 mm deep RCC precast rings along with 50mm dia holes from the invert level of percolation pit. The pit outer wall is constructed in precast RCC and crushed stone of 200mm thick all around it on PCC bed of 1:4:8 ratio. The first layer for 600mm thick is left hollow with 50mm dia holes around it. The second layer for 600mm thick is filled with 40mm gravel filling. The third layer for 600mm thick is filled with 65mm gravel filling. The fourth layer for 900mm thick is filled with brick bats. Finally the top of rain harvest pit is covered with RCC precast slab with perforation of (min) 50 mm dia in strip of size 2’0’ wide, to allow entry of surface / ground level rainwater.
| No | 61950.0 | 61950.0 | 15.0 | False | None | None | False | None | False | 929250.0 | 0 | 3262464 | 113012 | None | Least Quoted Rate | Heat pump for Hot water genaration
Supply in position, Electrical Heat exchanger type Heat pump unit of capacity as mentioned below, equipped with thermostat for automatic operation of boiler system, soft water reservoir of capacity mentioned below, with all necessary accessories like automatic temperature regulator, frame and base stand, necessary electrical connection, all necessary frames and structures for mounting the hot water generator etc., complete.
| Set | 1988300.0 | 1988300.0 | 2.0 | False | None | None | False | None | False | 3976600.0 | 0 | 3262465 | 113012 | None | Least Quoted Rate | Supplying of Grab Bar and Swing bars (Stainless Steel) of approved make as per details - Straight Disabled Grab Bar- Steel, Complete. (Grab bar and railings for disabled toilet)
Supplying and fixing of SS Grab bar Right 90ºAngle (L shape) with all Accessories (For Disable-friendly Bathroom)
Make: Jaquar, Cat. No.: WAC-SAP-BG0800CS & AHS 1507
| Set | 8242.3 | 8242.3 | 10.0 | False | None | None | False | None | False | 82423.0 | 0 |
| 1718022464000 | 0 | None | None | Buildings | WATER SUPPLY & SANITARY (EXTERNAL) | 10290356.65 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3262466 | 113013 | None | PWD SR P.No 122 It.No 13.33.2 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External Work
20 mm nominal dia Pipes
| Rmtr | 269.0 | 269.0 | 710.0 | False | None | None | False | None | False | 190990.0 | 0 | 3262467 | 113013 | None | PWD SR P.No 122 It.No 13.33.3 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External Work
25 mm nominal dia Pipes
| Rmtr | 367.0 | 367.0 | 1230.0 | False | None | None | False | None | False | 451410.0 | 0 | 3262468 | 113013 | None | PWD SR P.No 122 It.No 13.33.4 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External Work
32 mm nominal dia Pipes
| Rmtr | 461.0 | 461.0 | 890.0 | False | None | None | False | None | False | 410290.0 | 0 | 3262469 | 113013 | None | PWD SR P.No 123 It.No 13.33.5 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External Work
40 mm nominal dia Pipes
| Rmtr | 591.0 | 591.0 | 650.0 | False | None | None | False | None | False | 384150.0 | 0 | 3262470 | 113013 | None | PWD SR P.No 123 It.No 13.33.6 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External Work
50 mm nominal dia Pipes
| Rmtr | 893.0 | 893.0 | 645.0 | False | None | None | False | None | False | 575985.0 | 0 | 3262471 | 113013 | None | PWD SR P.No 123 It.No 13.33.7 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External Work
65 mm nominal dia Pipes
| Rmtr | 1735.0 | 1735.0 | 1120.0 | False | None | None | False | None | False | 1943200.0 | 0 | 3262472 | 113013 | None | PWD SR P.No 123 It.No 13.33.8 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External Work
80 mm nominal dia Pipes
| Rmtr | 2222.0 | 2222.0 | 480.0 | False | None | None | False | None | False | 1066560.0 | 0 | 3262473 | 113013 | None | V-5 P.No 32 It.No 2.46 | Supplying and fixing surface box of required dia. and size with synthetic lid for valves or spindle rods. The surface box should be usable for 50 to 400mm dia. valves, PN 10 / 16 and will consist of lid, housing, locking clip, notched bolt, cross bar, washer and torque nut.
| No | 4216.0 | 4216.0 | 1.0 | False | None | None | False | None | False | 4216.0 | 0 | 3262474 | 113013 | None | V-5 P.No 32 It.No 2.47 | B098A Supply & fixing RCC Pre-cast Cover Slab of size 0.8 m x 0.8 m x 0.2m of M25-Design mix concrete with 12 mm steel @ 120 mm c/c both ways, over Gate valve extension spindle with central opening along with lid for smooth operation with appurtenances., complete with all lead and lifts.
| No | 3581.0 | 3581.0 | 1.0 | False | None | None | False | None | False | 3581.0 | 0 | 3262475 | 113013 | None | V-5 P.No 133 It.No 11.5.2 | Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark.
For 20 mm dia GM (Copper alloy) Gate valves
| No | 1100.0 | 1100.0 | 20.0 | False | None | None | False | None | False | 22000.0 | 0 | 3262476 | 113013 | None | V-5 P.No 133 It.No 11.5.3 | Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark.
For 25 mm dia GM (Copper alloy) Gate valves
| No | 1448.4 | 1448.4 | 25.0 | False | None | None | False | None | False | 36210.0 | 0 | 3262477 | 113013 | None | V-5 P.No 133 It.No 11.5.4 | Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark.
For 32 mm dia GM (Copper alloy) Gate valves
| No | 1658.0 | 1658.0 | 20.0 | False | None | None | False | None | False | 33160.0 | 0 | 3262478 | 113013 | None | V-5 P.No 133 It.No 11.5.5 | Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark.
For 40 mm dia GM (Copper alloy) Gate valves
| No | 1859.0 | 1859.0 | 15.0 | False | None | None | False | None | False | 27885.0 | 0 | 3262479 | 113013 | None | V-5 P.No 133 It.No 11.5.6 | Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark.
For 50 mm dia GM (Copper alloy) Gate valves
| No | 2091.0 | 2091.0 | 15.0 | False | None | None | False | None | False | 31365.0 | 0 | 3262480 | 113013 | None | V-5 P.No 133 It.No 11.5.7 | Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark.
For 65 mm dia GM (Copper alloy) Gate valves
| No | 2316.0 | 2316.0 | 10.0 | False | None | None | False | None | False | 23160.0 | 0 | 3262481 | 113013 | None | V-5 P.No 133 It.No 11.16.4 | Providing GM (copper alloy) reflex valves/ globe valves confirming to Class-I and as per IS 778/1990 with latest amendments, 1 No. and with ISI mark screwed female ends confirming to IS 554/ 1990 horizontal body hydraulically tested for 1.50 HP and seat hydraulically tested 1 HP.
For 32 mm dia GM (Copper alloy) reflex valve
| No | 751.0 | 751.0 | 1.0 | False | None | None | False | None | False | 751.0 | 0 | 3262482 | 113013 | None | V-5 P.No 133 It.No 11.16.6 | Providing GM (copper alloy) reflex valves/ globe valves confirming to Class-I and as per IS 778/1990 with latest amendments, 1 No. and with ISI mark screwed female ends confirming to IS 554/ 1990 horizontal body hydraulically tested for 1.50 HP and seat hydraulically tested 1 HP.
For 50 mm dia GM (Copper alloy) reflex valve
| No | 984.0 | 984.0 | 2.0 | False | None | None | False | None | False | 1968.0 | 0 | 3262483 | 113013 | None | V-1 P.No 6 It.No 1.6.1 | Earth work excavation by manual means for drains,canals, waste weir draft, approach channels, key trench, foundation of Bridges and such similar works, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, excavated surface leveled and sides neatly dressed disposing off or leveling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work.
In ordinary/soft rock without blasting upto 1.5 m depth
For water supply line from BW to building and Sump to duct
| Cum | 675.0 | 675.0 | 37.0 | False | None | None | False | None | False | 24975.0 | 0 | 3262484 | 113013 | None | V-1 P.No 7 It.No 1.11 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
| Cum | 354.35 | 354.35 | 37.0 | False | None | None | False | None | False | 13110.95 | 0 | 3262485 | 113013 | None | V-2 P.No 117 It.No 13.2.1 | Providing and fixing brass bib cock of approved quality :15 mm nominal bore
| No | 354.35 | 354.35 | 20.0 | False | None | None | False | None | False | 7087.0 | 0 | 3262486 | 113013 | None | V-5 P.No 113 It.no 10.1.7 | Providing at site of work P.V.C. pipes including cost of pipes and specials and labour, including lowering into trenches, laying true to line, level and perfect linking at joints leak proof including jointing of approved type with all labour charges and all lift charges, handling charges including encasing the pipe around to a depth not less than 15 cms with gravel or selected earth available from the excavation etc. complete.
PVC pipes 75mm dia., 6 kg/sqcm & class 3 - Waste pipe
| Rmtr | 605.0 | 605.0 | 620.0 | False | None | None | False | None | False | 375100.0 | 0 | 3262487 | 113013 | None | V-5 P.No 113 It.No 10.1.9 | Providing at site of work P.V.C. pipes including cost of pipes and specials and labour, including lowering into trenches, laying true to line, level and perfect linking at joints leak proof including jointing of approved type with all labour charges and all lift charges, handling charges including encasing the pipe around to a depth not less than 15 cms with gravel or selected earth available from the excavation etc. complete.
PVC pipes 110mm dia., 6 kg/sqcm & class 3 - Soil pipe
| Rmtr | 1175.0 | 1175.0 | 530.0 | False | None | None | False | None | False | 622750.0 | 0 | 3262488 | 113013 | None | V-5 P.No 121 It.No 10.15.5 | Lowering, laying true to line and level of PVC Ringtite / PVC Pipes and cuts of pipes wherever necessary including jointing of pipes and specials with jointing of approved type, with all labour with encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS and commissioning (Contractor will make his own arrangements for procuring water for testing) etc. for:
75mm - Waste pipe
| Rmtr | 94.16 | 94.16 | 620.0 | False | None | None | False | None | False | 58379.2 | 0 | 3262489 | 113013 | None | V-5 P.No 121 It.No 10.15.7 | Lowering, laying true to line and level of PVC Ringtite / PVC Pipes and cuts of pipes wherever necessary including jointing of pipes and specials with jointing of approved type, with all labour with encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS and commissioning (Contractor will make his own arrangements for procuring water for testing) etc. for:
110mm - Soil pipe
| Rmtr | 139.0 | 139.0 | 530.0 | False | None | None | False | None | False | 73670.0 | 0 | 3262490 | 113013 | None | V-5 P.No 113 It.No 10.2.4 | Supplying UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. for:( For external Sanitary Work ).Pipes of SN4, 160mm dia.
| Rmtr | 714.0 | 714.0 | 335.0 | False | None | None | False | None | False | 239190.0 | 0 | 3262491 | 113013 | None | V-5 P.No 113 It.No10.2.5 | Supplying UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. for:( For external Sanitary Work ).Pipes of SN4, 200mm dia.
| Rmtr | 1029.6 | 1029.6 | 70.0 | False | None | None | False | None | False | 72072.0 | 0 | 3262492 | 113013 | None | PWD P.No 123 It.No 13.38 | Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design
100x100 mm size P type
19.4.1.2 - With Sewer bricks conforming to IS : 4885
| No | 3137.0 | 3137.0 | 25.0 | False | None | None | False | None | False | 78425.0 | 0 | 3262493 | 113013 | None | V-5 P.No 191 It.No 16.8 | Constructing brick masonry chamber of internal dimension 600x450mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.
| No | 6159.0 | 6159.0 | 40.0 | False | None | None | False | None | False | 246360.0 | 0 | 3262494 | 113013 | None | V-5 P.No 191 It.No 16.9 | Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.(INSPECTION CHAMBER)
| No | 6758.0 | 6758.0 | 18.0 | False | None | None | False | None | False | 121644.0 | 0 | 3262495 | 113013 | None | V-5 P.No 192 It.No 16.15.1 | Providing and constructing “WIRE CUT BRICK MACHINEHOLE CHAMBERS” using Portland/ Pozzolana cement, conical in shape at top, with CC 1:3:6 foundation using 40mm and down size graded metal of approved quality and with an offset of 0.15M alround the chamber. Construct Brick masonry in CM 1:4, 340 mm thick, with wirecut bricks of approved quality, plaster inside and out side with CM 1:3, 12mm thick, except for the conical surface outside where the plaster thickness shall be 20mm. Slope inside to be 1:6 in the concrete towards central drain and finished smooth. Fixing of pipes in CC 1:2:4 with graded metal of 20mm and down size. Supplying and fixing SFRC Machinehole frame and cover (Heavy Duty) conforming to IS:12592 with latest amendment, in CC 1:2:4. Supplying and fixing footsteps made of 12mm dia. steel bars (Fe-500) with 3mm thick plastic encapsulation (IS-10910). The footsteps shall be fixed 30cms apart and on CC block embeded to masonry wall. The whole works include watering, curing, barricading, danger lighting, pouring tar over MH frame and cover, cost of tar, shoring, strutting, de- watering, engraving Machinehole number with flow direction on the inner conical surface etc. as per the drawing etc. as per technical specifications and for the following diameters and depth etc. for 1.2mm diaCirc. B M.H:Constructing Brick Masonry Circular Machinehole 1.2 m internal dia. ,1.0 M depth & SFRC cover & frame
| No | 35989.0 | 35989.0 | 2.0 | False | None | None | False | None | False | 71978.0 | 0 | 3262496 | 113013 | None | V-5 P.No 192 It.No 16.15.2 | Providing and constructing “WIRE CUT BRICK MACHINEHOLE CHAMBERS” using Portland/ Pozzolana cement, conical in shape at top, with CC 1:3:6 foundation using 40mm and down size graded metal of approved quality and with an offset of 0.15M alround the chamber. Construct Brick masonry in CM 1:4, 340 mm thick, with wirecut bricks of approved quality, plaster inside and out side with CM 1:3, 12mm thick, except for the conical surface outside where the plaster thickness shall be 20mm. Slope inside to be 1:6 in the concrete towards central drain and finished smooth. Fixing of pipes in CC 1:2:4 with graded metal of 20mm and down size. Supplying and fixing SFRC Machinehole frame and cover (Heavy Duty) conforming to IS:12592 with latest amendment, in CC 1:2:4. Supplying and fixing footsteps made of 12mm dia. steel bars (Fe-500) with 3mm thick plastic encapsulation (IS-10910). The footsteps shall be fixed 30cms apart and on CC block embeded to masonry wall. The whole works include watering, curing, barricading, danger lighting, pouring tar over MH frame and cover, cost of tar, shoring, strutting, de- watering, engraving Machinehole number with flow direction on the inner conical surface etc. as per the drawing etc. as per technical specifications and for the following diameters and depth etc. for 1.2mm diaCirc. B M.H:Constructing Brick Masonry Circular Machinehole 1.2 m internal dia. ,1.1 M depth & SFRC cover & frame
| No | 36589.0 | 36589.0 | 1.0 | False | None | None | False | None | False | 36589.0 | 0 | 3262497 | 113013 | None | V-1 P.No 7 It.No 1.11 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
| Cum | 536.48 | 536.48 | 219.0 | False | None | None | False | None | False | 117489.12 | 0 | 3262498 | 113013 | None | V-5 P.No 113 It.No 10.1.5 | Providing at site of work P.V.C. pipes including cost of pipes and specials and labour, including lowering into trenches, laying true to line, level and perfect linking at joints leak proof including jointing of approved type with all labour charges and all lift charges, handling charges including encasing the pipe around to a depth not less than 15 cms with gravel or selected earth available from the excavation etc. complete.
PVC pipes 75mm dia., 6 kg/sqcm & class 3
| Rmtr | 605.0 | 605.0 | 15.0 | False | None | None | False | None | False | 9075.0 | 0 | 3262499 | 113013 | None | V-5 P.No 113 It.No 10.1.7 | Providing at site of work P.V.C. pipes including cost of pipes and specials and labour, including lowering into trenches, laying true to line, level and perfect linking at joints leak proof including jointing of approved type with all labour charges and all lift charges, handling charges including encasing the pipe around to a depth not less than 15 cms with gravel or selected earth available from the excavation etc. complete.
PVC pipes 110mm dia., 6 kg/sqcm & class 3
| Rmtr | 1175.0 | 1175.0 | 25.0 | False | None | None | False | None | False | 29375.0 | 0 | 3262500 | 113013 | None | V-5 P.No 121 It.No 10.15.5 | Lowering, laying true to line and level of PVC Ringtite / PVC Pipes and cuts of pipes wherever necessary including jointing of pipes and specials with jointing of approved type, with all labour with encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS and commissioning (Contractor will make his own arrangements for procuring water for testing) etc. for:
75mm
| Rmtr | 94.16 | 94.16 | 15.0 | False | None | None | False | None | False | 1412.4 | 0 | 3262501 | 113013 | None | V-5 P.no 121 It.No 10.15.7 | Lowering, laying true to line and level of PVC Ringtite / PVC Pipes and cuts of pipes wherever necessary including jointing of pipes and specials with jointing of approved type, with all labour with encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS and commissioning (Contractor will make his own arrangements for procuring water for testing) etc. for:
110mm
| Rmtr | 139.0 | 139.0 | 25.0 | False | None | None | False | None | False | 3475.0 | 0 | 3262502 | 113013 | None | V-5 P.No 191 It.No 16.9 | Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.(CATCH BASIN)
| No | 6758.0 | 6758.0 | 18.0 | False | None | None | False | None | False | 121644.0 | 0 | 3262503 | 113013 | None | V-1 P.No 6 It.No 1.6.1 | Earth work excavation by manual means for drains,canals, waste weir draft, approach channels, key trench, foundation of Bridges and such similar works, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, excavated surface leveled and sides neatly dressed disposing off or leveling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work.
In ordinary/soft rock without blasting upto 1.5 m depth
For rainwater allround
| Cum | 675.0 | 675.0 | 176.0 | False | None | None | False | None | False | 118800.0 | 0 | 3262504 | 113013 | None | V-1 P.No 7 It.No 1.11 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
| Cum | 536.0 | 536.0 | 179.0 | False | None | None | False | None | False | 95944.0 | 0 | 3262505 | 113013 | None | V-5 P.No 247 It.No 21.19 | Water purification plants: Supplying, Installation and Commissioning of automatic Water purification plant (RO+UF) with all accessories piping, product water tank on single phase power supply as per the enclosed detailed Technical Specifications including cost of material, loading and unloading and as directed by the Engineer in charge. (Ref- detailed specification enclosed seperatly). Note:- 1.The above rates mentioned are only for the preparation of estimate purpose. 2. All items are to be of BSI /NFS standards,with BSI / NFS mark . 3. Tenders to be invited for procurement. 4. No direct payment should be made under any situation or condition or on any account. 5. After commissioning of plant necessary testing to be done for the satisfactory of Engineer Incharge. Note : Refer the ANNEXURE : F for Detailed Specification of Each components
For 1000 LPH SS : Skid Type
| Each | 546399.0 | 546399.0 | 1.0 | False | None | None | False | None | False | 546399.0 | 0 | 3262506 | 113013 | None | V-2 It.No 13.34 | Providing and placing on terrace, polyethylene water storage tanks as per IS 12701 marked, with coverd and suitable locking aggangement and ackinh necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank Tank Capacity - 1000Lts
| Rmtr | 11.15 | 11.15 | 3000.0 | False | None | None | False | None | False | 33450.0 | 0 | 3262507 | 113013 | None | V-1 It.No 6 P.No 1.6.1 | Earth work excavation by manual means for drains,canals, waste weir draft, approach channels, key trench, foundation of Bridges and such similar works, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, excavated surface leveled and sides neatly dressed disposing off or leveling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work.
| Cum | 675.0 | 675.0 | 219.0 | False | None | None | False | None | False | 147825.0 | 0 | 3262508 | 113013 | None | PWD V-2 P.No 123 It.No 13.33.9 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External Work
100 mm nominal dia Pipes
| Rmtr | 3127.23 | 3127.23 | 60.0 | False | None | None | False | None | False | 187633.8 | 0 | 3262509 | 113013 | None | V-5 P.No 133 It.No 11.15.8 | Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark.
For 80 mm dia GM (Copper alloy) Gate valves
| No | 2356.57 | 2356.57 | 8.0 | False | None | None | False | None | False | 18852.56 | 0 | 3262510 | 113013 | None | V-5 P.No 133It.No 11.15.9 | Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark.
For 100 mm dia GM (Copper alloy) Gate valves
| No | 2430.91 | 2430.91 | 2.0 | False | None | None | False | None | False | 4861.82 | 0 | 3262511 | 113013 | None | V-5 P.No 133 It.No 11.16.3 | Providing GM (copper alloy) reflex valves/ globe valves confirming to Class-I and as per IS 778/1990 with latest amendments, 1 No. and with ISI mark screwed female ends confirming to IS 554/ 1990 horizontal body hydraulically tested for 1.50 HP and seat hydraulically tested 1 HP.
For 25 mm dia GM (Copper alloy) reflex valve
| No | 666.58 | 666.58 | 2.0 | False | None | None | False | None | False | 1333.16 | 0 | 3262512 | 113013 | None | V-5 P.No 133 It.No 11.16.5 | Providing GM (copper alloy) reflex valves/ globe valves confirming to Class-I and as per IS 778/1990 with latest amendments, 1 No. and with ISI mark screwed female ends confirming to IS 554/ 1990 horizontal body hydraulically tested for 1.50 HP and seat hydraulically tested 1 HP.For 40 mm dia GM (Copper alloy) reflex valve
| No | 890.84 | 890.84 | 4.0 | False | None | None | False | None | False | 3563.36 | 0 | 3262513 | 113013 | None | V-5 P.No 133 It.No 11.16.7 | Providing GM (copper alloy) reflex valves/ globe valves confirming to Class-I and as per IS 778/1990 with latest amendments, 1 No. and with ISI mark screwed female ends confirming to IS 554/ 1990 horizontal body hydraulically tested for 1.50 HP and seat hydraulically tested 1 HP.
For 65 mm dia GM (Copper alloy) reflex valve
| No | 1060.58 | 1060.58 | 3.0 | False | None | None | False | None | False | 3181.74 | 0 | 3262514 | 113013 | None | V-5 P.No 133 It.No 11.16.8 | Providing GM (copper alloy) reflex valves/ globe valves confirming to Class-I and as per IS 778/1990 with latest amendments, 1 No. and with ISI mark screwed female ends confirming to IS 554/ 1990 horizontal body hydraulically tested for 1.50 HP and seat hydraulically tested 1 HP.
For 80 mm dia GM (Copper alloy) reflex valve
| No | 1107.66 | 1107.66 | 1.0 | False | None | None | False | None | False | 1107.66 | 0 | 3262515 | 113013 | None | V-5 P.No 113 It.No 10.2.2 | Supplying UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. for:( For external Sanitary Work ).Pipes of SN4, 110mm dia.
| Rmtr | 356.83 | 356.83 | 330.0 | False | None | None | False | None | False | 117753.9 | 0 | 3262516 | 113013 | None | V-5 P.No 113 It.No 10.2.4 | Supplying UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. for:( For external Sanitary Work ).
Pipes of SN4, 160mm dia.
| Rmtr | 713.66 | 713.66 | 70.0 | False | None | None | False | None | False | 49956.2 | 0 | 3262517 | 113013 | None | V-5 P.No 192 It.No 16.15.3 | Constructing Brick Masonry Circular Machinehole 1.2 m internal dia. ,1.2 M depth & SFRC cover & frame
| No | 38867.43 | 38867.43 | 1.0 | False | None | None | False | None | False | 38867.43 | 0 | 3262518 | 113013 | None | V-5 P.No 113 It.No 10.1.9 | Providing at site of work P.V.C. pipes including cost of pipes and specials and labour, including lowering into trenches, laying true to line, level and perfect linking at joints leak proof including jointing of approved type with all labour charges and all lift charges, handling charges including encasing the pipe around to a depth not less than 15 cms with gravel or selected earth available from the excavation etc. complete.PVC pipes 160mm dia., 6 kg/sqcm & class 3
| Rmtr | 1680.82 | 1680.82 | 595.0 | False | None | None | False | None | False | 1000087.9 | 0 | 3262519 | 113013 | None | V-5 P.No 121 It.No 10.15.9 | Lowering, laying true to line and level of PVC Ringtite / PVC Pipes and cuts of pipes wherever necessary including jointing of pipes and specials with jointing of approved type, with all labour with encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS and commissioning (Contractor will make his own arrangements for procuring water for testing) etc. for:
160mm
| Rmtr | 156.11 | 156.11 | 595.0 | False | None | None | False | None | False | 92885.45 | 0 | 3262520 | 113013 | None | V-5 P.No 113 It.No 10.2.4 | Supplying UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. for:( For external Sanitary Work ).
Pipes of SN4, 160mm dia.
| Rmtr | 713.66 | 713.66 | 200.0 | False | None | None | False | None | False | 142732.0 | 0 | 3262521 | 113013 | None | V-5 P.No 113 It.no10.2.5 | Supplying UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. for:( For external Sanitary Work ).Pipes of SN4, 200mm dia.
| Rmtr | 1029.6 | 1029.6 | 150.0 | False | None | None | False | None | False | 154440.0 | 0 |
| 1718022464000 | 0 | None | None | Buildings | Lift (20 passenger cum bed lift)-5 No | 20751130.85 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3262522 | 113014 | None | Chapter-14 P.no 1 It.No 14.4.6 | Design, supplying, erecting testing and commissioning of - passenger/ Bed-cum-passenger hospital lift with speed of 1mtr per second, variable voltage variable frequency drive, with or without machine room for the available well size, operating at 415 V
3 phase 50 cycles AC supply, powder coated / Stainless Steel car entrance doors enclosures with suitable colour vinyl flooring, LED car illumination, emergency light, intercom and fan as desired by the user, central opening / side opening door with or
without attendant operation, 7 segment display buttons, call register indicator, fireman drive, SS handrails inside car, full length infrared curtain in car door, automatic rescue device with batteries, voice announcing in regional / international languages,
Braille buttons with one year warranty and maintenance with necessary scaffolding and minor civil works like fixing of guide rail, counter weight etc.
D. With Out Machine Room- SS- Finish
20 Passengers ( 4 Stops )
| Job | 3725426.17 | 3725426.17 | 5.0 | False | None | None | False | None | False | 18627130.85 | 0 | 3262523 | 113014 | None | Market Rate | Design, supplying, erecting, testing and commissioning of TECHNICAL SPECIFICATIONS :-
1. Type : electric dumb- waiter,Microprocessor controlled
2. Load : 100 kg
3. Speed : 0.25 mps.
4. Travel : 3 meters (approx.) Per floor
5. Floor designation : GF to SF
6. No. Of stops : two.
7. Car area : 450 mm (w) x 450 mm (d) x 700 mm.
8. Shaft area apprx 900 (w) x 750 (d).
9. Landing doors : stainless steel swing door.
10. Car enclosure : 304 stainless steel.
11. Car frame : a’ grade steel 3” x 1.5” channel.
12. Brake : electro mechanical a.c. brake non
Sparking type
13. Gear box : gear box with suitable
Reduction ratio
14. Motor : 3 phase inducti0n motor. (sharp/bbl/
Bmw motor.)
15. Coupling : fixed type coupling
16. Control : dumb waiter shall be single speed.
17. Machine position : machine with gear box to be placed
Directly on RCC slab provided over shaft. / machine to be
Placed directly on the i beam. (client scope).
18. Power supply : 415 V 5%, 2 KW 3 PHASE. The supplier shall be registered in Government Electrical Inspectorate in the State of Karnataka. | No | 2124000.0 | 2124000.0 | 1.0 | False | None | None | False | None | False | 2124000.0 | 0 |
| 1718022464000 | 0 | None | None | Buildings | UPS System | 4879300.0 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3262524 | 113015 | None | Least Quotation Rate | Supply of 20 KVA UNINTERRUPTED POWER SUPPLY SYSTEM with Moudular type : - Digital Technology Three Phase Input, Three Phase Output (With bi-directional Static and manual by-pass Switch).Hot swipable.
Modular type
With IGBT for Rectifier and Inverter
With Input current harmonics 3% (THDi)
With Input Power Factor 0.99
With overall efficiency 0.93%
Supply of Battery Backup 30 Minutes through sealed maintenance free [SMF] Baterries.
| No | 472000.0 | 472000.0 | 2.0 | False | None | None | False | None | False | 944000.0 | 0 | 3262525 | 113015 | None | Least Quotation Rate | Software monitoring/BMS Service/Per Battery
| No | 23600.0 | 23600.0 | 2.0 | False | None | None | False | None | False | 47200.0 | 0 | 3262526 | 113015 | None | Least Quotation Rate | Supply of Battery Accessories
Battery Breaker
Intererconnecting cables between batteries.
Battery stand for housing the batteries
Cables between UPS & Batteries [5 Mtrs. Max]
| No | 17700.0 | 17700.0 | 2.0 | False | None | None | False | None | False | 35400.0 | 0 | 3262527 | 113015 | None | Least Quotation Rate | Supply of 30 KVA UNINTERRUPTED POWER SUPPLY SYSTEM with Moudular type : - Digital Technology Three Phase Input, Three Phase Output (With Static with static by pass.switch).
Installation & commissioning charges.
| No | 11800.0 | 11800.0 | 2.0 | False | None | None | False | None | False | 23600.0 | 0 | 3262528 | 113015 | None | Least Quotation Rate | Supply of 30 KVA UNINTERRUPTED POWER SUPPLY SYSTEM with Moudular type : - Digital Technology Three Phase Input, Three Phase Output (With Static with static by pass.switch).
Modular type
* With IGBT for Rectifier and Inverter
* With Input current harmonics 3% (THDi)
With Input Power Factor 0.99
With overall efficiency 0.93%
Supply of Battery Backup 30 Minutes through sealed maintenance free [SMF] Baterries. | No | 1003000.0 | 1003000.0 | 3.0 | False | None | None | False | None | False | 3009000.0 | 0 | 3262529 | 113015 | None | Least Quotation Rate | Supply of 30 KVA UNINTERRUPTED POWER SUPPLY SYSTEM with Moudular type : - Digital Technology Three Phase Input, Three Phase Output (With Static with static by pass.switch).
Software monitoring/BMS Service/Per Battery
| No | 17700.0 | 17700.0 | 3.0 | False | None | None | False | None | False | 53100.0 | 0 | 3262530 | 113015 | None | Least Quotation Rate | Supply of Battery Accessories
Battery Breaker
Intererconnecting cables between batteries.
Battery stand for housing the batteries
Cables between UPS & Batteries [5 Mtrs. Max] | No | 29500.0 | 29500.0 | 3.0 | False | None | None | False | None | False | 88500.0 | 0 | 3262531 | 113015 | None | Least Quotation Rate | Supply of 30 KVA UNINTERRUPTED POWER SUPPLY SYSTEM with Moudular type : - Digital Technology Three Phase Input, Three Phase Output (With Static with static by pass.switch).
Installation & commissioning charges.
| No | 17700.0 | 17700.0 | 3.0 | False | None | None | False | None | False | 53100.0 | 0 | 3262532 | 113015 | None | Least Quotation RatE | Supply of 10 KVA UNINTERRUPTED POWER SUPPLY SYSTEM with Moudular type : - Digital Technology Three Phase Input, Three Phase Output (With bi-directional Static and manual by-pass Switch).Hot swipable.
Supply of Battery Backup 30 Minutes through sealed maintenance free [SMF] Baterries.
| No | 265500.0 | 265500.0 | 2.0 | False | None | None | False | None | False | 531000.0 | 0 | 3262533 | 113015 | None | Least Quotation RatE | Supply of 10 KVA UNINTERRUPTED POWER SUPPLY SYSTEM with Moudular type : - Digital Technology Three Phase Input, Three Phase Output (With bi-directional Static and manual by-pass Switch).Hot swipable.
Software monitoring/BMS Service/Per Battery
| No | 17700.0 | 17700.0 | 2.0 | False | None | None | False | None | False | 35400.0 | 0 | 3262534 | 113015 | None | Least Quotation Rate | Supply of Battery Accessories
Battery Breaker
Intererconnecting cables between batteries.
Battery stand for housing the batteries
Cables between UPS & Batteries [5 Mtrs. Max]
| No | 17700.0 | 17700.0 | 2.0 | False | None | None | False | None | False | 35400.0 | 0 | 3262535 | 113015 | None | Least Quotation Rate | Supply of 10 KVA UNINTERRUPTED POWER SUPPLY SYSTEM with Moudular type : - Digital Technology Three Phase Input, Three Phase Output (With bi-directional Static and manual by-pass Switch).Hot swipable.
Installation & commissioning charges.
| No | 11800.0 | 11800.0 | 2.0 | False | None | None | False | None | False | 23600.0 | 0 |
| 1718022464000 | 0 | None | None | Buildings | NETWORKING AND TELECOMMUNICATION | 3896666.25 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3262536 | 113016 | None | Chapter-8 PWD-SR P.No 36 It.No 8.1 | Supplying and drawing UTP-CAT 6E LAN cable.
| Rmtr | 47.08 | 47.08 | 12600.0 | False | None | None | False | None | False | 593208.0 | 0 | 3262537 | 113016 | None | Chapter-8 PWD-SR P.No 36 It.No 8.2.2 | Supplying and drawing PVC flexible one pair telephone unarmoured tinned copper cable.
2 Pair
| Rmtr | 26.02 | 26.02 | 6000.0 | False | None | None | False | None | False | 156120.0 | 0 | 3262538 | 113016 | None | Chapter-8 PWD-SR P.No 36 It.No 8.2.6 | Supplying and drawing PVC flexible one pair telephone unarmoured tinned copper cable.
20 Pair
| Rmtr | 185.85 | 185.85 | 100.0 | False | None | None | False | None | False | 18585.0 | 0 | 3262539 | 113016 | None | Chapter-8 PWD-SR P.No 36 It.No 8.4.10 | Supplying & Fixing of sitch mountng rack with power manager & Cable manager.
42U with 650mm depth
| Each | 53485.15 | 53485.15 | 3.0 | False | None | None | False | None | False | 160455.45 | 0 | 3262540 | 113016 | None | Chapter-8 PWD-SR P.No 36 It.No 8.9.2 | Supplying & Fixing of sitch mountng rack with power manager & Cable manager.
24 Port Gigabyte (manageable)
| Each | 51356.55 | 51356.55 | 3.0 | False | None | None | False | None | False | 154069.65 | 0 | 3262541 | 113016 | None | Chapter-8 PWD-SR P.No 36 It.No 8.5 | Supplying & Fixing of Power strip
| Each | 1805.22 | 1805.22 | 8.0 | False | None | None | False | None | False | 14441.76 | 0 | 3262542 | 113016 | None | Chapter-8 PWD-SR P.No 36 It.No 8.6 | Supplying of shelf
| Each | 1024.65 | 1024.65 | 8.0 | False | None | None | False | None | False | 8197.2 | 0 | 3262543 | 113016 | None | Chapter-8 PWD-SR P.No 36 It.No 8.7 | Supplying & fixing of Castor wheels to the Shelf (set of 4)
| Each | 1960.1 | 1960.1 | 3.0 | False | None | None | False | None | False | 5880.3 | 0 | 3262544 | 113016 | None | Chapter-8 PWD-SR P.No 36 It.No 8.8 | Supplying & Fixing of Fan
| Each | 1497.95 | 1497.95 | 11.0 | False | None | None | False | None | False | 16477.45 | 0 | 3262545 | 113016 | None | Chapter-8 PWD-SR P.No 36 It.No 8.10.1 | Supplying &fixing of I/Osocket, face plate with back box
Single I/O
| Each | 607.11 | 607.11 | 100.0 | False | None | None | False | None | False | 60711.0 | 0 | 3262546 | 113016 | None | Chapter-8 PWD-SR P.No 36 It.No 8.10.2 | Supplying &fixing of I/Osocket, face plate with back box
Double I/O
| Each | 681.45 | 681.45 | 200.0 | False | None | None | False | None | False | 136290.0 | 0 | 3262547 | 113016 | None | Chapter-8 PWD-SR P.No 37 It.No 8.11.3 | Supplying &fixing of 3mtr cat 6 Patch Cable
| Each | 410.11 | 410.11 | 200.0 | False | None | None | False | None | False | 82022.0 | 0 | 3262548 | 113016 | None | Chapter-8 PWD-SR P.No 37 It.No 8.12.5 | Supplying & Fixing of patch panel for LAN cabling
24 port 10/100/1000 patch panel
| Each | 9788.1 | 9788.1 | 9.0 | False | None | None | False | None | False | 88092.9 | 0 | 3262549 | 113016 | None | Chapter-8 PWD-SR P.No 37 It.No 8.13.2 | Supplying and fixing of MDF krone junction box with KRONE Module / Telephone cable termination
20 pair krone module with MDF BOX
| Each | 474.54 | 474.54 | 4.0 | False | None | None | False | None | False | 1898.16 | 0 | 3262550 | 113016 | None | Chapter-8 PWD-SR P.No 37 It.No 8.13.4 | Supplying and fixing of MDF krone junction box with KRONE Module / Telephone cable termination
50 pair krone module with MDF BOX
| Each | 781.81 | 781.81 | 1.0 | False | None | None | False | None | False | 781.81 | 0 | 3262551 | 113016 | None | Least Quotation Rate | 250 Pair Krone Module with MDF BOX
| Each | 11800.0 | 11800.0 | 1.0 | False | None | None | False | None | False | 11800.0 | 0 | 3262552 | 113016 | None | Least Quotation Rate | Supply, Installation, Testing & Commissioning of 6 core single mode Armored Optic fibre cable OS1/OS2 - loose tube indoor/outdoor Loose Tube - 2.8 mm jelly filled loose tube with 2-24 fibres, Sheath - 1,5 mm sheath, UV stabilised, IEC 50290-2-27 Colour = Yellow Ral 1018, Fire Rating IEC 60332-3-24 IEC 60332-1-2 IEC 60754-1 EN50399, Nominal outer diameter - 2-24 fibres : 7,3 mm, Min. Bending radius, unloaded E11 R = 73 mm, Min. Bending radius, loaded - R=146, Temperature range - Operation : - 30C to 70C. Standards and Norms - IEC 60793-2-50 category B.1.3 EN 60793-2-50: class B1.3 ITU Recommendation G.652.D - the other ITU designations A, B and C are also fulfilled. EN 50 173-1:2007, cat. OS2; also OS1 requirements are fulfilled. ISO/IEC 11801:2002, cat. OS1 ISO/IEC 24702:2006, cat. OS2; also OS1 requirements are fulfilled IEEE 802.3 - 2002 incl. 802.3ae. | Rmtr | 88.5 | 88.5 | 300.0 | False | None | None | False | None | False | 26550.0 | 0 | 3262553 | 113016 | None | Least Quotation Rate | Supply, Installation, Testing & Commissioning of 12 port LIU of 19 slide in modular optic drawers with galvanised steel accommodates up to 4 fibre optic units, 4 cables, accommodates up to 12ST and SC connectors and 12 LC connectors. Should meet EN50173 and ISO/IEC 11801 operating specifications.10 GB 9/125 microm OS2 LC L S Z H Pigtails confirming to ITU G651 and TIA/EIA 492AAAA standards | Each | 17700.0 | 17700.0 | 2.0 | False | None | None | False | None | False | 35400.0 | 0 | 3262554 | 113016 | None | Least Quotation Rate | Supply, Installation, Testing & Commissioning of 6 port LIU of 19" slide-in modular optic drawers with galvanised steel accommodates up to 4 fibre optic units, 4 cables, accommodates up to 6ST and SC connectors and 6 LC connectors. Should meet EN50173 and ISO/IEC 11801 operating specifications.10 GB - 9/125 micro m OS2 LC LSZH Pigtails confirming to ITU-G651 and TIA/EIA 492AAAA standards
| Each | 15340.0 | 15340.0 | 1.0 | False | None | None | False | None | False | 15340.0 | 0 | 3262555 | 113016 | None | Least Quotation Rate | Supply, Installation, Testing & Commissioning of LC/LC Duplex Patch Cords OS2 - 2 mtr. The OFC patchcords provide flexible interconnection to active equipment, passive optical devices and cross-connects. Maximum optical losses : 0.3 dB. IL MAX/Master (Acceptance) 0.3 dB as pe IEC 61300-3-4, MAX IL/Random 0.4 dB as per IEC 61300-3-34, Mechanical endurance 500 matings as per IEC 61300-2-2. Connector type IEC 61754-20 MM PC - Beige with clips Boot white. Cable Material LSZH/PVC.
| Each | 2950.0 | 2950.0 | 5.0 | False | None | None | False | None | False | 14750.0 | 0 | 3262556 | 113016 | None | Least Quotation Rate | Supply, Installation, Testing & Commissioning of Sfp Module Single Mode as rquired | Each | 5900.0 | 5900.0 | 15.0 | False | None | None | False | None | False | 88500.0 | 0 | 3262557 | 113016 | None | Least Quotation Rate | 12-Port Gigabit Fiber Metro Ethernet Switch, 2P10/100/1000BASE-T RJ-45 ports, 1G SFP ports, and 10G SFP+ ports,increased network bandwidth. Surge protection, advanced Layer 2 functions
| Each | 29500.0 | 29500.0 | 2.0 | False | None | None | False | None | False | 59000.0 | 0 | 3262558 | 113016 | None | Chapter-1 PWD-SR P.No 2 It.No 1.1.2 | Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc.and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary
25 mm dia 2mm thick
| Rmtr | 100.36 | 100.36 | 2000.0 | False | None | None | False | None | False | 200720.0 | 0 | 3262559 | 113016 | None | Least Quotation Rate | Supply & Fixing of GbESpeed Wifi Router, PoE Support.
| Each | 11800.0 | 11800.0 | 3.0 | False | None | None | False | None | False | 35400.0 | 0 | 3262560 | 113016 | None | Least Quotation Rate | 8 x 100/1000 Base-T 802.3at supported PoE+ Ports + 2 x 1GbE SFP Ports Managed Switch with SFP Transceiver Module x 2 Nos
| Each | 16520.0 | 16520.0 | 1.0 | False | None | None | False | None | False | 16520.0 | 0 | 3262561 | 113016 | None | Least Quotation Rate | EPABX:- Supply,Installation,Testing & Commissioning of micro-processor based, state of the Art, Telephone PBX System , IP READY,based on Linux/GRUB compliant, integrated Software for multiTasking for Hospitality Services including Billing ,comprising of items as below but not limited to them. 8Analog Trunk Lines 15 Digital Extensions 250 Analogue Extensions( Expandable up to 300) LAN Connectivity Embedded WELCOME MESSAGE Least Cost Routing Personal Assistant Music on Hold | Each | 973500.0 | 973500.0 | 1.0 | False | None | None | False | None | False | 973500.0 | 0 | 3262562 | 113016 | None | Least Quotation Rate | TELEPHONES Analog push button telephone with Caller ID, flash and radial
| Each | 2183.0 | 2183.0 | 100.0 | False | None | None | False | None | False | 218300.0 | 0 | 3262563 | 113016 | None | Least Quotation Rate | TELEPHONES Digital Phones
| Each | 8850.0 | 8850.0 | 12.0 | False | None | None | False | None | False | 106200.0 | 0 | 3262564 | 113016 | None | Least Quotation Rate | Supply,Installation,Testing & Commissioning of Facial Recognition , Biometric & Card. Dual Core 1.2Ghz Processor, Linux Operating System, Verification time 1 Second, 0.5-2Mtrs recognition distance, 512MB RAM, 8GB ROM, Communication WIFI,TCP/IP, USB, Wiegand IN/OUT, Power 12V/2A
| No | 44840.0 | 44840.0 | 2.0 | False | None | None | False | None | False | 89680.0 | 0 | 3262565 | 113016 | None | Least Quotation Rate | Supply & Fixing of T & A Software
| No | 59000.0 | 59000.0 | 1.0 | False | None | None | False | None | False | 59000.0 | 0 | 3262566 | 113016 | None | Chapter-8 PWD-SR P.No 36 It.No 8.1 | Supplying and drawing UTP-CAT 6E LAN cable
| Rmtr | 47.08 | 47.08 | 120.0 | False | None | None | False | None | False | 5649.6 | 0 | 3262567 | 113016 | None | Chapter-8 PWD-SR P.No 37 It.No 8.11.2 | Supplying &fixing of 2mtr cat 6 Patch Cable
| Each | 318.42 | 318.42 | 200.0 | False | None | None | False | None | False | 63684.0 | 0 | 3262568 | 113016 | None | Chapter-8 PWD-SR P.No 6 It.No 8.4.2 | Supplying & Fixing of sitch mountng rack with power manager & Cable manager.
6U with 450mm depth
| Each | 8644.5 | 8644.5 | 3.0 | False | None | None | False | None | False | 25933.5 | 0 | 3262569 | 113016 | None | Chapter-8 PWD-SR P.no 36 It.No 8.9.10 | Supplying & fixing of Networking Switches
24 Port 10/100/1000 Switch
| Each | 9187.19 | 9187.19 | 7.0 | False | None | None | False | None | False | 64310.33 | 0 | 3262570 | 113016 | None | Chapter-8 PWD-SR P.No 36 It.No 8.2.8 | Supplying and drawing PVC flexible one pair telephone unarmoured tinned copper cable.
50 Pair
| Rmtr | 503.03 | 503.03 | 450.0 | False | None | None | False | None | False | 226363.5 | 0 | 3262571 | 113016 | None | Chapter-8 PWD-SR P.no 36 It.No 8.9.11 | Supplying & fixing of Networking Switches
16 Port 10/100/1000 Switch
| Each | 7979.16 | 7979.16 | 4.0 | False | None | None | False | None | False | 31916.64 | 0 | 3262572 | 113016 | None | Chapter-8 PWD-SR P.No 37 It.No 8.12.6 | Supplying & Fixing of patch panel for LAN cabling
16 port 10/100/1000 patch panel
| Each | 9602.25 | 9602.25 | 3.0 | False | None | None | False | None | False | 28806.75 | 0 | 3262573 | 113016 | None | Chapter-8 PWD-SR P.No 37 It.No8.13.3 | Supplying and fixing of MDF krone junction box with KRONE Module / Telephone cable termination
30 pair krone module with MDF BOX
| Each | 703.75 | 703.75 | 3.0 | False | None | None | False | None | False | 2111.25 | 0 |
| 1718022464000 | 0 | None | None | Buildings | CCTV | 4578738.83 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3262574 | 113017 | None | Least Quotation Rate | Supply, Installation, Testing & Commissioning of 4MP Lite IR Fixedfocal Dome Network Camera ,1 / 3 CMOS image sensor, low illuminance, high image definition Outputs 4 MP 2560 x 1440 at 25 / 30 fps, max. supports 4MP 2688 1520 20 fps, H 265 codec high compression rate, ultralow bit rate Builtin IR LED, max IR distance 40 m, ROI, SMART H 264+/H.265+ , flexible coding, applicable to various bandwidth and storage environment Rotation mode, WDR, 3D NR, HLC, BLC, digital watermarking, applicable to various monitoring scenes,Intelligent detection Intrusion,tripwire,Abnormality detection Motion detection, video tampering, no SD card,SD card full, SD card error, network disconnected, IP conflict, illegal access, voltage detection, Supports max. 256 GB Micro SD card,Inbuilt 64 GB micro SD card,12V DC/PoE power supply IP67, IK10 protectionThe prices should include the necessary mounts and brackets | Each | 12390.0 | 12390.0 | 111.0 | False | None | None | False | None | False | 1375290.0 | 0 | 3262575 | 113017 | None | Least Quotation Rate | Supply, Installation, Testing & Commissioning of 4MP IP Indoor Dome VF Camera with 1 / 2.8 CMOS Image Sensor , 2.7mm13.5mm Motorized lens, 2688 (H) 1520 (V) resolution, 0.008 Lux @ F1.5, IR Illumination Up to 40m IR Distance, BLC, HLC, WDR, White Balance: (Auto, Natural, Street Lamp, Outdoor, Manual, Customized Region), 3D DNR Noise Reduction, Privacy Masking, ROI, H.265/H.264/MJpeg Compression, Dual Stream, Motion Detection, Video Tampering, Tripwire Intrusion Analytics, RJ 45 (10/100Base T), IPv4; IPv6; HTTP; TCP; UDP; ARP; RTP ; RTSP; RTCP; RTMP; SMTP; FTP; SFTP; DHCP; DNS; DDNS; QoS; UPnP; NTP; Multicast; ICMP; IGMP; NFS; PPPoE; Bonjour. Cyber security: Video encryption; firmware encryption; configuration encryption; Digest; WSSE; account lockout; security logs; IP/MAC filtering; generation and importing of X.509 certification; syslog; HTTPS; 802.1x; trusted boot; trusted execution; trusted upgrade. Alarm events: No SD card; SD card full; SD card error; network disconnection; IP conflict; motion detection; video tampering; tripwire; intrusion; illegal access; voltage detection; audio detection; safety exception; local alarm. 1 channel (RCA port) Audio In, 1 channel (RCA port) Audio Out, Alaram In/out: 1/1, Supports max. 256 GB Micro SD card. DC12V, PoE (802.3 af)(Class 0) IP67, IK10, CE, FCC,UL. -30C 60C Operating Temperature | Each | 21240.0 | 21240.0 | 15.0 | False | None | None | False | None | False | 318600.0 | 0 | 3262576 | 113017 | None | Least Quotation Rate | Supply,Installation,Testing &Commissioningof 5MP WDR IR Bullet WizMind Network Camera ,1/2.7”5Megapixel progressive scan CMOS, ROI, SMART H.264+/H.265+, flexible coding, applicable to various bandwidth and storage environments,20 fps@2592 1944, 50/60 fps@1080P (1920 1080),WDR (120 dB), Day/Night (ICR), 3D DNR, AWB, AGC, BLCMultiple network monitoring: Web viewer, CMS (DSS/PSS) & DMSS ,2.8 mm fixed lens (3.6 mm, 6.0 mm optional),1/1 Alarm in/out, 1/1 audio in/out,Max. IR LEDs Length 50m,Micro SD memory, IP67, IK10,Built-in micro SD/SDHC/SDXC card slot,up to 128 GB Inbuilt 64 GB micro SD card, DC12V, PoE (802.3 af)(Class 0), IK10 Vanidal Resistance, The prices should include the necessary mounts and brackets. | Each | 20060.0 | 20060.0 | 4.0 | False | None | None | False | None | False | 80240.0 | 0 | 3262577 | 113017 | None | Least Quotation Rate | Supply, Installation, Testing & Commissioning of 32ch NVR with Industrial embedded micro-processor, Embedded Linux operating system, 320 Mbps bandwidth, supporting resolution 12MP, 8MP, 6MP, 5MP, 4MP, 3MP, 1080p, 1.3MP, 720p, D1, and more, Smart H.265+; Smart H.264+; H.265; H.264; MJPEG compression, HTTP; HTTPS; TCP/IP; IPv4/IPv6; UPnP; SNMP; RTSP; UDP; SMTP; NTP; DHCP; DNS; IP Filter; PPPoE; DDNS; FTP; Alarm Server; IP Search, P2P protocols supporting, ONVIF (profile T/S/G), Manual; schedule record modes, disk group options, should supports analytics features of the cameras like, perimeter protection, face detection, ANPR, Video metadata, Audio ports in/out: 1/2, Alarm ports in/out: 16/6, should support 4 SATA III ports, up to 10 TB for a single HDD, eSATA, RS232, RS485, 1 front USB 2.0 port, 2 rear USB 3.0 port, 2 HDMI, 2 VGA, 2 RJ-45 10/100/1000 Mbps self-adaptive Ethernet port, 10C to +55C (+14F to +131F), CE, FCC, UL cirtified | Each | 64900.0 | 64900.0 | 5.0 | False | None | None | False | None | False | 324500.0 | 0 | 3262578 | 113017 | None | Least Quotation Rate | 6TB HDD (Surveillance or Enterprise Grade)
| Each | 23600.0 | 23600.0 | 18.0 | False | None | None | False | None | False | 424800.0 | 0 | 3262579 | 113017 | None | Least Quotation Rate | 24P x 100/1000 GbE Base-T 802.3at supported PoE+ Ports + 2 x 1GbE SFP Ports Managed Switch with Layer 2+ Image, 50 operating temperature support | Each | 29500.0 | 29500.0 | 1.0 | False | None | None | False | None | False | 29500.0 | 0 | 3262580 | 113017 | None | Least Quotation Rate | 16P x 100/1000 GbE Base-T 802.3at supported PoE+ Ports + 2 x 1GbE SFP Ports Managed Switch with Layer 2+ Image, 50 operating temperature support
| Each | 29500.0 | 29500.0 | 7.0 | False | None | None | False | None | False | 206500.0 | 0 | 3262581 | 113017 | None | Chapter-8 PWD-SR P.No 37 It.No 8.12.5 | Supplying & Fixing of patch panel for LAN cabling
24 port 10/100/1000 patch panel
| Each | 9788.1 | 9788.1 | 6.0 | False | None | None | False | None | False | 58728.6 | 0 | 3262582 | 113017 | None | Chapter-8 PWD-SR P.No 36 It.No 8.11.1 | Supplying &fixing of 1mtr cat 6 Patch Cable
| Each | 277.54 | 277.54 | 133.0 | False | None | None | False | None | False | 36912.82 | 0 | 3262583 | 113017 | None | Least Quotation Rate | Category 6 Field termination Plug with 4 x 4 PVC boxes
| Each | 194.7 | 194.7 | 133.0 | False | None | None | False | None | False | 25895.1 | 0 | 3262584 | 113017 | None | Chapter-8 PWD-SR P.No 36 It.No 8.4.2 | Supplying & Fixing of sitch mountng rack with power manager & Cable manager.
6U with 450mm depth
| Each | 8644.5 | 8644.5 | 6.0 | False | None | None | False | None | False | 51867.0 | 0 | 3262585 | 113017 | None | Chapter-8 PWD-SR P.no 36 It.No 8.5 | Supplying & Fixing of Power strip
| Each | 1805.22 | 1805.22 | 8.0 | False | None | None | False | None | False | 14441.76 | 0 | 3262586 | 113017 | None | Chapter-8 PWD-SR P.No 36 It.No 8.6 | Supplying of shelf
| Each | 1024.65 | 1024.65 | 6.0 | False | None | None | False | None | False | 6147.9 | 0 | 3262587 | 113017 | None | Chapter-8 PWD-SR P.No 36 It.No 8.8 | Supplying & Fixing of Fan
| Each | 1497.95 | 1497.95 | 8.0 | False | None | None | False | None | False | 11983.6 | 0 | 3262588 | 113017 | None | Chapter-1 PWD-SR P.No 2 It.No 1.2.2 | Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc.and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary
25 mm dia 2mm thick
| Rmtr | 100.36 | 100.36 | 3280.0 | False | None | None | False | None | False | 329180.8 | 0 | 3262589 | 113017 | None | Chapter-8 PWD-SR P.No 36 It.No 8.1 | Supplying and drawing UTP-CAT 6E LAN cable.
| Rmtr | 47.08 | 47.08 | 6800.0 | False | None | None | False | None | False | 320144.0 | 0 | 3262590 | 113017 | None | Least Quotation Rate | Supplying & Fixing of 42" HD TV with HDMI Cable & Acessories ( Fixing option Wall Mount & Table Mount both option required)
| Each | 64900.0 | 64900.0 | 5.0 | False | None | None | False | None | False | 324500.0 | 0 | 3262591 | 113017 | None | Least Quotation Rate | SFP Single mode Gbs tranceiver module
| Each | 5900.0 | 5900.0 | 16.0 | False | None | None | False | None | False | 94400.0 | 0 | 3262592 | 113017 | None | Least Quotation Rate | Supply, Installation, Testing & Commissioning of 6 core single mode Armored Optic fibre cable OS1/OS2 - loose tube indoor/outdoor Loose Tube - 2.8 mm jelly filled loose tube with 2-24 fibres, Sheath - 1,5 mm sheath, UV stabilised, IEC 50290-2-27 Colour = Yellow Ral 1018, Fire Rating IEC 60332-3-24 IEC 60332-1-2 IEC 60754-1 EN50399, Nominal outer diameter - 2-24 fibres : 7,3 mm, Min. Bending radius, unloaded E11 R = 73 mm, Min. Bending radius, loaded - R=146, Temperature range - Operation : - 30C to 70C. Standards and Norms - IEC 60793-2-50 category B.1.3 EN 60793-2-50: class B1.3 ITU Recommendation G.652.D - the other ITU designations A, B and C are also fulfilled. EN 50 173-1:2007, cat. OS2; also OS1 requirements are fulfilled. ISO/IEC 11801:2002, cat. OS1 ISO/IEC 24702:2006, cat. OS2; also OS1 requirements are fulfilled IEEE 802.3 - 2002 incl. 802.3ae. | Rmtr | 88.5 | 88.5 | 200.0 | False | None | None | False | None | False | 17700.0 | 0 | 3262593 | 113017 | None | Least Quotation Rate | Supply and Installation of Fiber Optic Patch Chord for OFC Cable The rate shall include all mounting accessories complete as required - etc.,
| No | 2950.0 | 2950.0 | 8.0 | False | None | None | False | None | False | 23600.0 | 0 | 3262594 | 113017 | None | Least Quotation Rate | Supply and Installation of 6P LIU For OFC Cable Termination The rate shall include all mounting accessories complete as required - etc
| No | 15340.0 | 15340.0 | 1.0 | False | None | None | False | None | False | 15340.0 | 0 | 3262595 | 113017 | None | Least Quotation Rate | Fiber Termination box
| No | 708.0 | 708.0 | 10.0 | False | None | None | False | None | False | 7080.0 | 0 | 3262596 | 113017 | None | Least Quotation Rate | Supply, Installation & Commissioning of 4MP 32x Starlight IR WizSense Network PTZ Camera,1/2.8" 4Megapixel STARVIS CMOS,Maximum Resolution 2560 (H) 1440 (V),Powerful 32x optical zoom,Max. 25/30fps@4M,IR distance up to 150 m, Focal Length 4.9mm - 156mm, Event Trigger:Motion detection, video tampering, scene changing,Network disconnection, IP address conflict, illegalaccess, and storage anomaly, Video Compression: H.265; H.264B; H.264M; H.264H; MJPEG (Sub Stream);H.265+ H.264+, Electronic Image Stabibilisation ,Deep-learning-based auto tracking and perimeter protection, WDR 120db ,SMDPLUS,PoE+,IP67, IK10, Micro SD memory, IP67, IK10,Built-in micro SD/SDHC/SDXC card slot,up to 128 GB Inbuilt 64 GB micro SD card,Face Detection, AC 24V/3A 25% (standard)PoE (802.3at)The prices should include the necessary mounts and brackets. | Each | 147500.0 | 147500.0 | 3.0 | False | None | None | False | None | False | 442500.0 | 0 | 3262597 | 113017 | None | Chapter-8 PWD-SR P.No 36 It.No 8.4.6 | Supplying & Fixing of sitch mountng rack with power manager & Cable manager.
24U with 450mm depth
| Each | 38887.25 | 38887.25 | 1.0 | False | None | None | False | None | False | 38887.25 | 0 |
| 1718022464000 | 0 | None | None | Buildings | PA SYSTEM | 1356071.19 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3262598 | 113018 | None | P.No 58 It.No 17.3.3 PWD ELE SR | Supply & Installation of 6W RMSWall Mount Cabinet Speaker with power taps at 6/4/2 on 100V, 60-15,000 Hz with all Accessories,
| Each | 2221.53 | 2221.53 | 52.0 | False | None | None | False | None | False | 115519.56 | 0 | 3262599 | 113018 | None | P.No 58 It.No 17.3.1 PWD ELE SR | Supply, Installation, Testing & commissioning of Public Address System 6 Zone Voice Alarm controller/ Preamplifier/ Mixer amplifer, Inbuilt 240W Amplifier, Auto fire evacualtion message with USB MP3 AM FM CAT 6 connectivity for Mic
| Each | 156623.23 | 156623.23 | 1.0 | False | None | None | False | None | False | 156623.23 | 0 | 3262600 | 113018 | None | Least Quotation Rate | Supply, Installation, Testing & commissioning of Power Amplifier 400 W
| Each | 53100.0 | 53100.0 | 4.0 | False | None | None | False | None | False | 212400.0 | 0 | 3262601 | 113018 | None | P.No 59 It.No 17.3.9 PWD ELE SR | Supply, Installation, testing & Commissioning of Voice Command Keypad 6 Zone, with microphone assembley complete as required.
| No | 101295.68 | 101295.68 | 1.0 | False | None | None | False | None | False | 101295.68 | 0 | 3262602 | 113018 | None | PWD ELE SR It.No 17.5.3.1 | Supply & Installation of 2Cx1.5 Sqmm transprent annealead plain flexible electrolytic grade copper wire and acessories
| Each | 66.91 | 66.91 | 3500.0 | False | None | None | False | None | False | 234185.0 | 0 | 3262603 | 113018 | None | Chapter-8 PWD-SR P.No 36 It.no 8.1 | Supplying and drawing UTP-CAT 6E LAN cable
| Rmtr | 47.08 | 47.08 | 120.0 | False | None | None | False | None | False | 5649.6 | 0 | 3262604 | 113018 | None | Chapter-1 PWD-SR P.No 2 It.No 1.2.2 | Supplying and fixing of 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc.and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary
25 mm dia 2mm thick
| Rmtr | 100.35 | 100.35 | 2700.0 | False | None | None | False | None | False | 270945.0 | 0 | 3262605 | 113018 | None | Chapter-8 PWD-SR P.No 36 it.No 8.4.6 | Supplying & Fixing of sitch mountng rack with power manager & Cable manager.
24U with 450mm depth
| Each / BW | 38887.25 | 38887.25 | 1.0 | False | None | None | False | None | False | 38887.25 | 0 | 3262606 | 113018 | None | Chapter-8 PWD-SR P.No 36 It.No 8.4.5 | Supplying & Fixing of sitch mountng rack with power manager & Cable manager.
Supplying & Fixing of Power strip
| Each | 1805.22 | 1805.22 | 1.0 | False | None | None | False | None | False | 1805.22 | 0 | 3262607 | 113018 | None | Chapter-8 PWD-SR P.No 36 It.No 8.6 | Supplying of shelf
| Each | 1024.65 | 1024.65 | 2.0 | False | None | None | False | None | False | 2049.3 | 0 | 3262608 | 113018 | None | Chapter-8 PWD-SR P.No 36 It.No 8.8 | Supplying & Fixing of Fan
| Each | 1497.95 | 1497.95 | 1.0 | False | None | None | False | None | False | 1497.95 | 0 | 3262609 | 113018 | None | Chapter-17 PWD-SR22 P.No 58 It.No 17.3.2 | Supply, Installation,Testing & commissioning of 1.5/3/6w Ceiling Speaker Complete as required
| Each | 1195.63 | 1195.63 | 180.0 | False | None | None | False | None | False | 215213.4 | 0 |
| 1718022464000 | 0 | None | None | Buildings | External Electrification AND Lt cables & Dg set For Hospital | 12028968.41 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3262610 | 113019 | None | CSR 2023-24p20itm45.04 | 11 kV, Jointing & Cable Termination Kit as
per IS-13573
Heat Shrinkable Type Transition Jointing Kit for XLPE Cable
Heat Shrinkable Indoor Type Cable Termination Kit
for XLPE Cable
3x95 Sqmm
| Set | 4638.82 | 4638.82 | 10.0 | False | None | None | False | None | False | 46388.2 | 0 | 3262611 | 113019 | None | CSR - 2023-24p20itm5.07 | Heat Shrinkable Outdoor Type Cable Termination
Kit for XLPE Cable
3x95 Sqmm
| Set | 5039.01 | 5039.01 | 4.0 | False | None | None | False | None | False | 20156.04 | 0 | 3262612 | 113019 | None | CSR2023-24p52tm22.04 | Making and Fixing pot head for HT Cable only
Heat shrinkable type
3x95 to 3x150 Sqmm
| Nos | 3293.26 | 3293.26 | 14.0 | False | None | None | False | None | False | 46105.64 | 0 | 3262613 | 113019 | None | CSR 2023-24p15itm36.01 | 11 kV, 3 Core, XPLE HTUG Cable with pressure extruded inner sheeth, ROUND WIRE ARMOURED as per IS-7098 (Part-2) Armouring wires dia and Resistivity as per IS-3975
95 Sqmm, (54 GI Wires - 2.5 mm Dia)
| Km | 1102296.17 | 1102296.17 | 0.35 | False | None | None | False | None | False | 385803.6595 | 0 | 3262614 | 113019 | None | CSR - 2023-24p52itm21.01 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff
3x95 to 150 Sqmm
| Km | 75977.96 | 75977.96 | 0.35 | False | None | None | False | None | False | 26592.286 | 0 | 3262615 | 113019 | None | CSR - 2023-24p16itm39.02 | 4 Way RMU 2OD + 2VL ( One Incomer + Two Breakers + One Outgoing) 630 Amps with Copper Busbar | Unit | 961260.8 | 961260.8 | 1.0 | False | None | None | False | None | False | 961260.8 | 0 | 3262616 | 113019 | None | CSR - 2023-24p26itm58.01 | 11 kV HT Metering cubicle of different CT Ratio, Both side cable entry type with 3 CT & 3 PT, With Transparent Cover TTB, with 30x8 mm Copper Busbar, Modem & 2 No of Meters for 3 Phase 4 Wire Metering without Load Break Switch (HT Metering Box Fabricated out of 3 mm MS Sheet duly epoxy powder coated) as per revised Specification
(Dwg No. BESCOM/GM/QS&S/- Dtd 24.11.2018) | Unit | 301661.81 | 301661.81 | 1.0 | False | None | None | False | None | False | 301661.81 | 0 | 3262617 | 113019 | None | CSR - 2023-24p17itm41.01 | Load Break Switch with Panel
| No | 90743.12 | 90743.12 | 2.0 | False | None | None | False | None | False | 181486.24 | 0 | 3262618 | 113019 | None | CSR - 2023-24p7itm12.20 | B. CABLE ENTRY TYPE
500 kVA, Aluminium wdg, star2 (5 Star)
| No | 1132172.18 | 1132172.18 | 2.0 | False | None | None | False | None | False | 2264344.36 | 0 | 3262619 | 113019 | None | Common SR 21-22p2 0f 14p4.06 | Construction of platform (1.5x1.5x1.2) mtr in size stone, for erection of transformers/Heavy equipment including all materials, labour.Excavation of (1.5x1.5x1) mt pit for foundation providing and laying cement concrete 1:4:8 for foundation laid in 1cm thick layers, well compacted curing etc., complete providing and construction of stone masonary 0.9m below ground level and 1.2m above ground level neatly hammer dressed in cement morter 1:6 cutting complete providing pointing to stone masonary in cement morter 1:3 after racking joint & nisely lining curing etc., plastering the concrete surfaces in cement morter 1:4 including smooth randering curing etc., curing at every stages completely.
| Per Structure | 37617.28 | 37617.28 | 6.0 | False | None | None | False | None | False | 225703.68 | 0 | 3262620 | 113019 | None | p22itm51.01 | GI Grounding pipe, B - Class, 42 mm dia, 2.5 Mtr long,
3.2 mm thick with bolt, nut, GI Strips and washer complete
Minimum Weight of GI Pipe: 7.3 Kg
| No | 920.58 | 920.58 | 24.0 | False | None | None | False | None | False | 22093.92 | 0 | 3262621 | 113019 | None | p22itm51.02 | Good Quality well burnt Charcoal for grounding purposes packed in non returnable gunny bag of 30 Kg each | Nos | 837.56 | 837.56 | 24.0 | False | None | None | False | None | False | 20101.44 | 0 | 3262622 | 113019 | None | p22itm51.03 | Good Quality Salt for grounding purposes packed in 50
Kg gunny bag | Bag | 384.09 | 384.09 | 24.0 | False | None | None | False | None | False | 9218.16 | 0 | 3262623 | 113019 | None | p23itm51.04 | Rod type of earthing using 40 mm Dia, 3 Mtr long MS
rod as ground rod, in earth pit of 300 mm width and
3300 mm depth and using 50x6 mm flat welded to ground rod as terminal & connected to equipment ground terminal using PVC Al wire as specified
| No | 2691.11 | 2691.11 | 16.0 | False | None | None | False | None | False | 43057.76 | 0 | 3262624 | 113019 | None | p23itm51.05 | Bentonite clay slurry for earthing in 50 Kg Bag | Bag | 455.95 | 455.95 | 16.0 | False | None | None | False | None | False | 7295.2 | 0 | 3262625 | 113019 | None | CSR - 2023-24p23itm52.01 | Alkathine tube
Transparent Alkathine tube 19 mm dia, 2 mm thick in coils of 30 Mtr
| Coil | 640.56 | 640.56 | 10.0 | False | None | None | False | None | False | 6405.6 | 0 | 3262626 | 113019 | None | CSR23-24P43ITM1.6.1 | Digging of Pit for providing GI Pipe type Earthing
Ordinary Soil
| Per Pit | 940.4 | 940.4 | 20.0 | False | None | None | False | None | False | 18808.0 | 0 | 3262627 | 113019 | None | CSRpage43itm1.6.2 | Digging of Pit for providing GI Pipe type Earthing
Hard Soil
| Per Pit | 3704.61 | 3704.61 | 10.0 | False | None | None | False | None | False | 37046.1 | 0 | 3262628 | 113019 | None | Chapter -1254 of 105itm12.56 | Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40 mm dia 2.90 mm thick GI pipe 2.5m long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150 mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12 mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia | No | 4348.89 | 4348.89 | 2.0 | False | None | None | False | None | False | 8697.78 | 0 | 3262629 | 113019 | None | Chapter -12 54 of 105itm12.57 | Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc. using 40 mm dia 2.9 mm thick 2.5m long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode.The funnel should be enclosed in a CC chamber of 400x400x400 mm with a cast iron cover. The earth electrode shall have staggered holes of 12 mm dia and the electrode should be covered 150 mm all-round with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts. | No | 5273.18 | 5273.18 | 2.0 | False | None | None | False | None | False | 10546.36 | 0 | 3262630 | 113019 | None | CSR - 2023-24p32of 81itm68.06 | Cable Covering Tile 125x250x40 mm
| Per 100 | 12705.95 | 12705.95 | 0.2 | False | None | None | False | None | False | 2541.19 | 0 | 3262631 | 113019 | None | CSR - 2023-24p32of81itm68.07 | Cable Covering Tile 125x125x40 mm | Per 100 | 6352.35 | 6352.35 | 0.2 | False | None | None | False | None | False | 1270.47 | 0 | 3262632 | 113019 | None | 68.01 | RCC Hume Pipe 2000 mm long 150 mm Dia | No | 380.37 | 380.37 | 10.0 | False | None | None | False | None | False | 3803.7 | 0 | 3262633 | 113019 | None | itm68.02 | Collars for RCC Hume Pipe 200 mm Dia
| No | 483.21 | 483.21 | 20.0 | False | None | None | False | None | False | 9664.2 | 0 | 3262634 | 113019 | None | CSR - 2023-24p32 of 81itm68.03 | Collars for RCC Hume Pipe 150 mm Dia | No | 101.6 | 101.6 | 6.0 | False | None | None | False | None | False | 609.6 | 0 | 3262635 | 113019 | None | CSR - 2023-24p32 of 81itm68.04 | Collars for RCC Hume Pipe 200 mm Dia | No | 127.62 | 127.62 | 11.0 | False | None | None | False | None | False | 1403.82 | 0 | 3262636 | 113019 | None | CSR - 2023-24p32 of 81itm68.08 | Route & Joint indicating slab with MS Anchor rod | No | 164.79 | 164.79 | 25.0 | False | None | None | False | None | False | 4119.75 | 0 | 3262637 | 113019 | None | CSR - 2023-24p32 of 81itm68.09 | Black Cambric tape 25 mm wide 10 mil thick and in rolls of 50 Mtr | Roll | 162.31 | 162.31 | 10.0 | False | None | None | False | None | False | 1623.1 | 0 | 3262638 | 113019 | None | CSR - 2023-24p32 of 81itm68.1 | Yellow Cambric tape 25 mm wide 7 mil thick and in rolls of 50 Mtr | Roll | 148.68 | 148.68 | 10.0 | False | None | None | False | None | False | 1486.8 | 0 | 3262639 | 113019 | None | CSR - 2023-24itm2.16 | Spiral Earth Electrode | Set | 307.27 | 307.27 | 2.0 | False | None | None | False | None | False | 614.54 | 0 | 3262640 | 113019 | None | CSR - 2023-24itm68.17 | Caution/Danger Board | No | 185.85 | 185.85 | 2.0 | False | None | None | False | None | False | 371.7 | 0 | 3262641 | 113019 | None | Chpter-12itm12.58.3 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required.
25x6mm GI strip - Fencing,RMU,HT Breacker & LTK
| Mtr | 158.59 | 158.59 | 100.0 | False | None | None | False | None | False | 15859.0 | 0 | 3262642 | 113019 | None | Chpter-12itm12.58.4 | 40x6mm GI strip - Tr. Body | Mtr | 224.26 | 224.26 | 35.0 | False | None | None | False | None | False | 7849.1 | 0 | 3262643 | 113019 | None | Chpter-12itm12.58.6 | 600x600x3mm GI Plate - Body earthing | Each | 1084.13 | 1084.13 | 6.0 | False | None | None | False | None | False | 6504.78 | 0 | 3262644 | 113019 | None | Chpter-12itm12.58.7 | 25x3mm Copper strip - Tr. Neutral | Mtr | 706.23 | 706.23 | 60.0 | False | None | None | False | None | False | 42373.8 | 0 | 3262645 | 113019 | None | Chpter-12itm12.58.11 | 600x600x3mm Copper plate - Tr.Neutral | Each | 9194.62 | 9194.62 | 3.0 | False | None | None | False | None | False | 27583.86 | 0 | 3262646 | 113019 | None | LQR | Chain Link Fencing-Supplying & fixing M.S rectangular pole made of 2 equal angles 65 x 65 x 6 mm welded together & fixed in C.C (1:2:4) with 2 nos 16 mm dia MS welded fost rods equal of length 25 mm including cost of all materials cutting, bending, scarffolding where ever necessary, nicely finishing the welded joints with all lead and lift as per the direction of the engineer incharge of the work and including, provoiding 2 coats of approved quality paint over 1 coat of shop painting (excluding cost of earth work and concreate). | Rmtr | 1672.65 | 1672.65 | 75.0 | False | None | None | False | None | False | 125448.75 | 0 | 3262647 | 113019 | None | LQR | Providing Chain link fencing 50 mm size of 8 gauage properly streched between rectangular poles and fixed with sutable bolt & nuts, the free ends shall be welded to the pole & black pipe at top & bottom as required including cost of all materials, labour,
| Sqmm | 1053.15 | 1053.15 | 75.0 | False | None | None | False | None | False | 78986.25 | 0 | 3262648 | 113019 | None | LQR | Supply Intstallation & Spreading of 40mm thick metal, 80mm depth in outdoor H.T yard
| Sqm | 867.3 | 867.3 | 45.0 | False | None | None | False | None | False | 39028.5 | 0 | 3262649 | 113019 | None | LQR | Supplying of two bucket stand alongwith buckets. Complete
| Each | 780.57 | 780.57 | 4.0 | False | None | None | False | None | False | 3122.28 | 0 | 3262650 | 113019 | None | LQR | Rubber Hand Gloves 15 kV,SEAMLESS Confirming to IS
| Pair | 210.63 | 210.63 | 4.0 | False | None | None | False | None | False | 842.52 | 0 | 3262651 | 113019 | None | LQR | Supplying of first aid box. Complete
| Each | 743.4 | 743.4 | 4.0 | False | None | None | False | None | False | 2973.6 | 0 | 3262652 | 113019 | None | LQR | Supplying of SAFETY MASK. Complete
| Each | 79.3 | 79.3 | 10.0 | False | None | None | False | None | False | 793.0 | 0 | 3262653 | 113019 | None | LQR | Supplying of FIRST AID CHART with lamination. Complete
| Each | 278.78 | 278.78 | 4.0 | False | None | None | False | None | False | 1115.12 | 0 | 3262654 | 113019 | None | Chapter-5PAGE20ITM5.42 | Fabricating supplying and mounting MS box made out
.SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with
7tanks treatment with powder coated paint and finally finished with approved colour etc., complete
| Sq CM | 0.62 | 0.62 | 550000.0 | False | None | None | False | None | False | 341000.0 | 0 | 3262655 | 113019 | None | Chapter-5PAGE20ITM5.40.2 | Supplying . A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete
1000 A double run of 4x60x10 mm Aluminium Strips
| m | 13108.62 | 13108.62 | 39.0 | False | None | None | False | None | False | 511236.18 | 0 | 3262656 | 113019 | None | Chapter-5PAGE20ITM5.41.3 | Supplying and fixing angle iron frame work fabricated out of
M.S. angle iron. and M.S. Flat.with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint.
75 x 75 x 6 mm
| m | 687.65 | 687.65 | 21.0 | False | None | None | False | None | False | 14440.65 | 0 | 3262657 | 113019 | None | Chapter-5PAGE17ITM5.15.20 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.
FOUR Pole
Incomers/Outgoing
700-800 A 50KA
| Each | 61826.1 | 61826.1 | 2.0 | False | None | None | False | None | False | 123652.2 | 0 | 3262658 | 113019 | None | Chapter-5PAGE17ITM5.15.20 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.Out Goings
700-800 A 50KA
| Each | 61826.1 | 61826.1 | 2.0 | False | None | None | False | None | False | 123652.2 | 0 | 3262659 | 113019 | None | Chapter-5PAGE18ITM5.18.9 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.
50-63 A TPN - For TVSS Connectivity
| Each | 3826.03 | 3826.03 | 2.0 | False | None | None | False | None | False | 7652.06 | 0 | 3262660 | 113019 | None | Chapter-5PAGE19ITM5.38 | Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz
12/24V D.C. | Each | 638.09 | 638.09 | 6.0 | False | None | None | False | None | False | 3828.54 | 0 | 3262661 | 113019 | None | Chapter-5PAGE18ITM5.22 | Supplying, fixing and wiring 0 to 600V 96x96mm AC
Voltmeter on existing panel/wood board
| Each | 560.03 | 560.03 | 6.0 | False | None | None | False | None | False | 3360.18 | 0 | 3262662 | 113019 | None | Chapter-5PAGE18ITM5.21 | Supplying, fixing and wiring earth leakage relay with core
balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board
| Each | 11466.95 | 11466.95 | 6.0 | False | None | None | False | None | False | 68801.7 | 0 | 3262663 | 113019 | None | Chapter-5PAGE18ITM5.26 | Supplying, fixing and wiring 0 to 1500A CT operated AC analog
type Ammeter without CT
| Each | 594.72 | 594.72 | 6.0 | False | None | None | False | None | False | 3568.32 | 0 | 3262664 | 113019 | None | Chapter-5PAGE19ITM5.28 | Supplying, fixing and wiring rotary selector switch suitable
for Voltmeter
| Each | 198.24 | 198.24 | 6.0 | False | None | None | False | None | False | 1189.44 | 0 | 3262665 | 113019 | None | Chapter-2PAGE5ITM2.3.2 | Wiring for lighting/power circuit using one of FRLS PVC
insulated 1100V grade, multistrand copper wire with low
conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.
1.5 mm2
| m | 32.21 | 32.21 | 180.0 | False | None | None | False | None | False | 5797.8 | 0 | 3262666 | 113019 | None | Chapter-2PAGE5ITM2.3.3 | Wiring for lighting/power circuit using one of FRLS PVC
insulated 1100V grade, multistrand copper wire with low
conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.
2.5 mm2
| Each | 52.04 | 52.04 | 150.0 | False | None | None | False | None | False | 7806.0 | 0 | 3262667 | 113019 | None | Chapter-2PAGE5ITM2.30 | Supplying, fixing and wiring 3 Phase TVSS
| Each | 17345.0 | 17345.0 | 2.0 | False | None | None | False | None | False | 34690.0 | 0 | 3262668 | 113019 | None | CSR - 2023-24P32ITM68.06 | Cable Covering Tile 125x250x40 mm
| Per 100 | 12705.95 | 12705.95 | 0.6 | False | None | None | False | None | False | 7623.57 | 0 | 3262669 | 113019 | None | CSR - 2023-24P32ITM68.07 | Cable Covering Tile 125x125x40 mm
| Per 100 | 6352.35 | 6352.35 | 0.6 | False | None | None | False | None | False | 3811.41 | 0 | 3262670 | 113019 | None | CSR - 2023-24P32ITM68.01 | RCC Hume Pipe 2000 mm long 150 mm Dia
| No | 380.37 | 380.37 | 20.0 | False | None | None | False | None | False | 7607.4 | 0 | 3262671 | 113019 | None | CSR - 2023-24P32ITM68.02 | RCC Hume Pipe 2000 mm long 200 mm Dia
| No | 483.21 | 483.21 | 40.0 | False | None | None | False | None | False | 19328.4 | 0 | 3262672 | 113019 | None | CSR - 2023-24P32ITM68.03 | Collars for RCC Hume Pipe 150 mm Dia
| No | 105.32 | 105.32 | 12.0 | False | None | None | False | None | False | 1263.84 | 0 | 3262673 | 113019 | None | CSR - 2023-24P32ITM68.04 | Collars for RCC Hume Pipe 200 mm Dia
| No | 127.62 | 127.62 | 22.0 | False | None | None | False | None | False | 2807.64 | 0 | 3262674 | 113019 | None | CSR - 2023-24P32ITM68.08 | Route & Joint indicating slab with MS Anchor rod
| No | 164.79 | 164.79 | 25.0 | False | None | None | False | None | False | 4119.75 | 0 | 3262675 | 113019 | None | CSR - 2023-24P32ITM68.09 | Black Cambric tape 25 mm wide 10 mil thick and in rolls of 50 Mtr
| Roll | 162.31 | 162.31 | 10.0 | False | None | None | False | None | False | 1623.1 | 0 | 3262676 | 113019 | None | CSR - 2023-24P32ITM68.1 | Yellow Cambric tape 25 mm wide 7 mil thick and in rolls of 50 Mtr
| Roll | 148.68 | 148.68 | 10.0 | False | None | None | False | None | False | 1486.8 | 0 | 3262677 | 113019 | None | CSR - 2023-24f81ITM2.16 | Spiral Earth Electrode | Set | 307.27 | 307.27 | 12.0 | False | None | None | False | None | False | 3687.24 | 0 | 3262678 | 113019 | None | CSR - 2023-24 ITM68.17 | Caution/Danger Board
| No | 180.89 | 180.89 | 6.0 | False | None | None | False | None | False | 1085.34 | 0 | 3262679 | 113019 | None | Chpter-12PAGE54ITM12.58.2 | GI/Copper strips for grounding connections, using necessary fixing materials as required. (Chapter - 12)
25x3mm GI strip
| Mtr | 101.6 | 101.6 | 180.0 | False | None | None | False | None | False | 18288.0 | 0 | 3262680 | 113019 | None | Chpter-12PAGE54ITM12.58.3 | GI/Copper strips for grounding connections, using necessary fixing materials as required. (Chapter - 12)
25x6mm GI strip
| Mtr | 158.59 | 158.59 | 120.0 | False | None | None | False | None | False | 19030.8 | 0 | 3262681 | 113019 | None | Chpter-12PAGE54ITM12.58.4 | GI/Copper strips for grounding connections, using necessary fixing materials as required. (Chapter - 12)
40x6mm GI strip
| Mtr | 224.26 | 224.26 | 80.0 | False | None | None | False | None | False | 17940.8 | 0 | 3262682 | 113019 | None | Chpter-12PAGE55ITM12.58.6 | GI/Copper strips for grounding connections, using necessary fixing materials as required. (Chapter - 12)
600x600x3mm GI Plate
| Each | 1084.13 | 1084.13 | 16.0 | False | None | None | False | None | False | 17346.08 | 0 | 3262683 | 113019 | None | Chpter-12PAGE55ITM12.58.7 | GI/Copper strips for grounding connections, using necessary fixing materials as required. (Chapter - 12)
25x3mm Copper strip
| Mtr | 706.23 | 706.23 | 60.0 | False | None | None | False | None | False | 42373.8 | 0 | 3262684 | 113019 | None | Chpter-12PAGE55ITM12.58.11 | GI/Copper strips for grounding connections, using necessary fixing materials as required. (Chapter - 12)
600x600x3mm Copper plate
| Each | 9194.62 | 9194.62 | 4.0 | False | None | None | False | None | False | 36778.48 | 0 | 3262685 | 113019 | None | LQR | Chain Link Fencing-Supplying & fixing M.S rectangular pole made of 2 equal angles 65 x 65 x 6 mm welded together & fixed in C.C (1:2:4) with 2 nos 16 mm dia MS welded fost rods equal of length 25 mm including cost of all materials cutting, bending, scarffolding where ever necessary, nicely finishing the welded joints with all lead and lift as per the direction of the engineer incharge of the work and including, provoiding 2 coats of approved quality paint over 1 coat of shop painting (excluding cost of earth work and concreate).
| Rmtr | 1672.65 | 1672.65 | 45.0 | False | None | None | False | None | False | 75269.25 | 0 | 3262686 | 113019 | None | LQR | Providing Chain link fencing 50 mm size of 8 gauage properly streched between rectangular poles and fixed with sutable bolt & nuts, the free ends shall be welded to the pole & black pipe at top & bottom as required including cost of all materials, labour,
| Sqmm | 1053.15 | 1053.15 | 24.0 | False | None | None | False | None | False | 25275.6 | 0 | 3262687 | 113019 | None | LQR | Supplying and fixing angle iron frame work iabricated out of M.S. angle iron. and M.S. flat . with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 75x75x6mm
| Mtr | 817.74 | 817.74 | 30.0 | False | None | None | False | None | False | 24532.2 | 0 | 3262688 | 113019 | None | Least Quotation Rate | Supply Intstallation & Spreading of 40mm thick metal, 80mm depth in outdoor H.T yard
| Sqm | 867.3 | 867.3 | 40.0 | False | None | None | False | None | False | 34692.0 | 0 | 3262689 | 113019 | None | Least Quotation RatE | Supplying of two bucket stand alongwith buckets. Complete
| Each | 780.57 | 780.57 | 4.0 | False | None | None | False | None | False | 3122.28 | 0 | 3262690 | 113019 | None | Least Quotation Rate | Rubber Hand Gloves 15 kV,SEAMLESS Confirming to IS
| Pair | 210.63 | 210.63 | 4.0 | False | None | None | False | None | False | 842.52 | 0 | 3262691 | 113019 | None | Least Quotation Rate | Supplying of first aid box. Complete | Each | 1365.38 | 1365.38 | 4.0 | False | None | None | False | None | False | 5461.52 | 0 | 3262692 | 113019 | None | Least Quotation Rate | Supplying of SAFETY MASK. Complete | Each | 79.3 | 79.3 | 5.0 | False | None | None | False | None | False | 396.5 | 0 | 3262693 | 113019 | None | Least Quotation Rate | Supplying of FIRST AID CHART with lamination. Complete
| Each | 278.78 | 278.78 | 2.0 | False | None | None | False | None | False | 557.56 | 0 | 3262694 | 113019 | None | CSR - 2023-24itm2.16 | Spiral Earth Electrode | Set | 86.73 | 86.73 | 12.0 | False | None | None | False | None | False | 1040.76 | 0 | 3262695 | 113019 | None | CSR - 2023-24itm68.17 | Caution/Danger Board
| No | 65.67 | 65.67 | 10.0 | False | None | None | False | None | False | 656.7 | 0 | 3262696 | 113019 | None | CSR - 2023-24itm2.16 | Spiral Earth Electrode
| Set | 115.23 | 115.23 | 2.0 | False | None | None | False | None | False | 230.46 | 0 | 3262697 | 113019 | None | Chapter-10 P.No 40.41.42 It.No 10.1.16 PWD ELE SR | Supplying, installing, testing and commissioning of Diesel Generator set with following specifications. Power rating as per
standard reference condition as per-BS 5514/ISO 3046/ ISO
8528 & IS 1002/ISO 3046 Generator set specifications.Engine: Diesel generating set are rated at 1500RPM and
conform to ISO 8528 specifications. The engines are radiator
cooled, four stroke and multi cylinder, conforming to ISO
3046. The scope of supply includes: Electrical starter motor12V
DC Battery charging alternator, Bosch fuel system with
mechanical governor, A1 Class. Spin-on lube oil filter, Spin-on
dual fuel filter with water separator, Turbocharger, Charge air
cooler, Silencer (Hospital grade), Dry type air cleaner,
Shutoff coil, Flywheel and flywheel housing, First fill of lube
oil and coolant, Safety for low lube oil pressure, Safety for high
water temperature, Permissible overload of 10% for one hour
in 12 hours of operation
Capacity of Fuel Tank: Fuel tank suitable for 8 hours of
operation
Alternator: Alternator is suitable for operation at 1500 RPM,
415 V, 0.8 pf (lag) suitable for 50 Hz, 3 phase, 4 wire systems,
conforming to IS/IEC 60034-1. The Alternator is brush less
type, screen protected, revolving field, self excited, self regulated
through an AVR. The alternator shall have+/- 1.0% Voltage
regulation (max) in static conditions- IP: 23 protections with
insulation class F&H.
Mounting arrangement: Engine and alternator are mounted on
a common MS fabricated base frame with AVM pads
Control Panel: The control panel is manufactured with 14/16
gauge CRCA sheet and is powder coated for weather-proof and
long lasting finish. The control panel consists of the following
parts PS0500 Controller, Aluminium bus bars with
suitable capacity within/outgoing terminals, Indicating lA for
'Load On' and 'Set Running', Instrument fuses duly wired
and ferruled, MCCB of suitable rating with overload and
short circuit protections."
Genset Controller: microprocessor based generator set
monitoring and control system. The control provides a
simple operator interface to the generator set, manual and
remote start/ stop control, shutdown fault indication, and
an LCD hour counter. The integration of all functions into a
single control system provides enhanced reliability and
performance compared to conventional generator set control
systems. This control has been designed and tested to meet
harsh environment in which gensets are typically applied.
Features, Functions, protections 16 character x 2 line
alphanumeric LCD display with LED Backlight"
"Operator interface, Provide a record of most recent fault
conditions. Fault history stored in the control non volatile
memory, Provide Alternator Data. Voltage (1 ph or 3 ph line to
line and line to neutral voltage, Current (1 ph or 3 ph), kVA (3
ph and total), Frequency, Provide Engine Data, Starting battery
voltage, Engine running hours, Engine Temp, Engine oil
pressure, Control includes provision for Service adjustment and
calibration of DG control functions, Voltage, frequency
selection, Configurable input and output set up, Meter
calibration, Engine controls, Power Start operates on 12 VDC
batteries,-Auto start mode accepts a ground signal from remote
devices to automatically start the DG set The remote start will
also wake up the control system from sleep mode.
Engine Starting The control system supports automatic engine
starting, Primary and back up start disconnects are achieved by
battery charging alternator feedback or main alternator output
frequency. Controller provide configurable time delay of 0-300
sees to start after remote start signal and time delay of 0600secs
prior to shut down after stop signal. Sleep mode
increase battery life. Configurable current settings from low
to minimize current draw when genset is not working. Engine
Protective functions include, Configurable alarm output,
Emergency stop Annunciated whenever an emergency stop
signal is received 500 kVA / 400 KW | Set | 4701188.5 | 4701188.5 | 1.0 | False | None | None | False | None | False | 4701188.5 | 0 | 3262698 | 113019 | None | Least Quotation Rate | Supply and installation of Exhaust piping using 200MM dia of M.S. as per IS including hardwares like flanges, bends, bolts & Gaskets etc, for Connection of Exhaust Piping from DG set complete with supporting Structures& Foundation etc complete. The same shall conform to CPCB norms. | Rmtr | 5369.0 | 5369.0 | 35.0 | False | None | None | False | None | False | 187915.0 | 0 | 3262699 | 113019 | None | Least Quotation Rate | Supply and fixing of MS angle channel with anchor fasteners for supporting of exhaust / fuel piping with epoxy painting
| Kg | 218.3 | 218.3 | 1250.0 | False | None | None | False | None | False | 272875.0 | 0 | 3262700 | 113019 | None | Least Quotation Rate | Providing thermal cladding for 200 exhaust pipe by mineral wool wrapping with chicken mesh and Alu. sheet including bends.
| Rmtr | 1652.0 | 1652.0 | 35.0 | False | None | None | False | None | False | 57820.0 | 0 | 3262701 | 113019 | None | Chapter-2 P.No 6 It.No 2.5.9 | Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990.
4C X 2.5Sq.mm
| Rmtr | 183.37 | 183.37 | 80.0 | False | None | None | False | None | False | 14669.6 | 0 | 3262702 | 113019 | None | Chapter-2 P.No 6 It.No 2.5 | Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990
4C X 4Sq.mm
| Rmtr | 278.77 | 278.77 | 75.0 | False | None | None | False | None | False | 20907.75 | 0 | 3262703 | 113019 | None | Chapter-6 P.No 42 It.No 6.11.1 | Supplying and fixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) ( SR 2019-2020 )
19/20mm
| Each | 84.25 | 84.25 | 12.0 | False | None | None | False | None | False | 1011.0 | 0 | 3262704 | 113019 | None | Chapter-6 P.No 43 It.No 6.17.2 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. ( SR 2019-2020 )
2.5 sqmm
| Each | 4.95 | 4.95 | 24.0 | False | None | None | False | None | False | 118.8 | 0 | 3262705 | 113019 | None | Chapter-6 P.No 43 It.No 6.17.3 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. ( SR 2019-2020 )
4 sqmm
| Each | 8.67 | 8.67 | 24.0 | False | None | None | False | None | False | 208.08 | 0 | 3262706 | 113019 | None | Chapter-12 P.No 54 It.No 12.57 | Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc. using 40mm dia 2.9mm thick 2.5 mtr long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode.The funnel should be enclosed in a CC chamber of 400x400x400mm with a cast iron cover. The earth electrode shall have staggered holes of 12mm dia and the electrode should be covered 150mm all-round with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts. | Each | 5273.18 | 5273.18 | 2.0 | False | None | None | False | None | False | 10546.36 | 0 | 3262707 | 113019 | None | Chapter-12 P.No 54 It.No 12.58.2 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required.
25x3mm GI strip - In Cable Trays & All Electrical Equipments.
| Rmtr | 101.6 | 101.6 | 40.0 | False | None | None | False | None | False | 4064.0 | 0 | 3262708 | 113019 | None | Chapter-12 P.No 55 It.No 12.58.6 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required.
600x600x3mm GI Plate | Each | 1084.13 | 1084.13 | 2.0 | False | None | None | False | None | False | 2168.26 | 0 | 3262709 | 113019 | None | Chapter-12 P.No 55 It.No 12.58.7 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required.
25x3mm Copper strip
| Rmtr | 706.23 | 706.23 | 55.0 | False | None | None | False | None | False | 38842.65 | 0 | 3262710 | 113019 | None | Chapter-12 P.No 54 It.No 12.58.11 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 600x600x3mm Copper plate
| Each | 9194.62 | 9194.62 | 2.0 | False | None | None | False | None | False | 18389.24 | 0 | 3262711 | 113019 | None | Chapter-12 P.no 54 It.No 12.56 | Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40mm dia 2.90mm thick GI pipe 2.5 mtr long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia. | Each | 4348.89 | 4348.89 | 2.0 | False | None | None | False | None | False | 8697.78 | 0 | 3262712 | 113019 | None | Chapter-8 P.no 26 It.No 7.1.3 | Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of following size direct in ground including excavation,snd cushioning,protective covering and refilling the trench etc as required. 1000 X 450 X 750 mm(LxWxD)
Above 95 sq.mm and upto 185 sq, mm
| Rmtr | 94.16 | 94.16 | 60.0 | False | None | None | False | None | False | 5649.6 | 0 | 3262713 | 113019 | None | Chapter-6 P.No 48 It.No 48.8 | GI Pipe B - Class as per IS-1239
GI Pipe - 100 mm Dia
| Rmtr | 1604.5 | 1604.5 | 10.0 | False | None | None | False | None | False | 16045.0 | 0 | 3262714 | 113019 | None | Chapter-12 It.No 12.60.1 | Supplying & Fixing Chemical earthling for grounding. Conduits, IC cut-outs & other equipments backfill compound which is noncorrosive, thermally conductive, potential to permissible limits, superior Fault conduction capacity, non toxic, weather resistance & capable of achieving ohmic value less than one ohm Using 4ft. Copper bonded rod with backfill compound | Kit | 5610.19 | 5610.19 | 1.0 | False | None | None | False | None | False | 5610.19 | 0 | 3262715 | 113019 | None | Chapter - 12 It.No 12.60.03 | Supplying & Fixing Chemical earthling for grounding. Conduits, IC cut-outs & other equipments backfill compound which is non corrosive, thermally conductive, potential to permissible limits, superior Fault conduction capacity, non toxic, weather resistance & capable of achieving ohmic value less than one ohm
Using 10ft. Copper bonded rod with backfill compound
| Kit | 10524.06 | 10524.06 | 1.0 | False | None | None | False | None | False | 10524.06 | 0 |
| 1718022464000 | 0 | None | None | Buildings | SUMP TANK | 6175636.53 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3262716 | 113020 | None | V-3 P.No 7 It.No 2.5A | Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness.By Mechanical Means using Dozer In area of light jungle
| Sqm | 486.93 | 486.93 | 2.13 | False | None | None | False | None | False | 1037.1609 | 0 | 3262717 | 113020 | None | V-1 P.No 8 It.No 1.14.1 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work 1.14.1 In all kinds of soils Depth upto 3 m.
| Cum | 126.38 | 126.38 | 447.3 | False | None | None | False | None | False | 56529.774 | 0 | 3262718 | 113020 | None | V-1 P.No 7 It.No 1.9 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
| Cum | 329.57 | 329.57 | 551.67 | False | None | None | False | None | False | 181813.8819 | 0 | 3262719 | 113020 | None | V-1 P.No 15 It,.No 2.1.3 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates. Including FormWork
| Cum | 7420.37 | 7420.37 | 21.3 | False | None | None | False | None | False | 158053.881 | 0 | 3262720 | 113020 | None | V-1 P.No 17 It.No 2.2.5 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
A. Raft
| Cum | 8293.9 | 8293.9 | 55.76 | False | None | None | False | None | False | 462467.864 | 0 | 3262721 | 113020 | None | V-1 P.No 17 It.No 2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
pump room and sump tank-walls
| Cum | 13688.84 | 13688.84 | 45.84 | False | None | None | False | None | False | 627496.4256 | 0 | 3262722 | 113020 | None | V-1 P.No 17 It.No 2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
Cover slab
| Cum | 12078.39 | 12078.39 | 38.4 | False | None | None | False | None | False | 463810.176 | 0 | 3262723 | 113020 | None | V-1 P.No 17 It.No 2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
ROOF BEAM
| Cum | 12883.62 | 12883.62 | 1.58 | False | None | None | False | None | False | 20356.1196 | 0 | 3262724 | 113020 | None | V-1 P.No 17 It.No 2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
COLOUMNS
| Cum | 13688.84 | 13688.84 | 1.44 | False | None | None | False | None | False | 19711.9296 | 0 | 3262725 | 113020 | None | V-1 P.No 18 It.No 2.11 h | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.All other type of structures
| Kg | 97894.63 | 97894.63 | 15.07 | False | None | None | False | None | False | 1475272.0741 | 0 | 3262726 | 113020 | None | V-2 p.No 17 It.no 6.32 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.
Pumproom
| Cum | 1623.09 | 1623.09 | 45.0 | False | None | None | False | None | False | 73039.05 | 0 | 3262727 | 113020 | None | V-2 P.No 77 It.No 11.5.1 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in- Charge.
| Sqm | 5548.24 | 5548.24 | 4.2 | False | None | None | False | None | False | 23302.608 | 0 | 3262728 | 113020 | None | V-2 P.No86 it.No 11.34A | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding | Kg | 208.15 | 208.15 | 75.6 | False | None | None | False | None | False | 15736.14 | 0 | 3262729 | 113020 | None | V-2 P.No 42 It.No 8.8 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 459.67 | 459.67 | 956.72 | False | None | None | False | None | False | 439775.4824 | 0 | 3262730 | 113020 | None | V-2 P.No 48 It.No 8.40 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 142.49 | 142.49 | 7.8 | False | None | None | False | None | False | 1111.422 | 0 | 3262731 | 113020 | None | V-2 P.No 44 It.No 8.21 | Providing White washing with lime to give an even shade :New work (three coats) with lime of approved quality, including cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 32.21 | 32.21 | 956.72 | False | None | None | False | None | False | 30815.9512 | 0 | 3262732 | 113020 | None | V-2 P.No 45 It.No 8.28 | Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 110.27 | 110.27 | 956.72 | False | None | None | False | None | False | 105497.5144 | 0 | 3262733 | 113020 | None | V-5 P.No 221 it.No 18.3 | Providing & fixing 455x610 mm cast iron cover with frame weight to be not less 38kgs (weight of cover 23 kgs and weight of frame 15 kgs)and necessary locking arrangements with M.S flats 32x6 mm etc & painting with two or more coats with black Japan paint etc. complete as directed by the engineer-in-charge.
| No | 2430.92 | 2430.92 | 8.0 | False | None | None | False | None | False | 19447.36 | 0 | 3262734 | 113020 | None | V-2 P.No 47 It.No 8.34.3 | Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
| Cum | 61.95 | 61.95 | 7.8 | False | None | None | False | None | False | 483.21 | 0 | 3262735 | 113020 | None | V-2 P.No 152 It.No 15.14 | UGT/OHT (inside) waterproofing with Anti-microbial Coating-Providing and Applying two component, water-based food grade epoxy resin coating on inside surface of Potable water tank having anti-algae, antifungal, Non-toxic, hygiene cum damp-proof coating Certified by CFTRI as per 21 CFR 175 300 of US FDA, having mixing Ratio (Base: Hardener: Water) 1:1:1 to be applied @ 0.35 Kg/m2 in 2 coats. Ensure that this coating is applied over the protective plaster, and that Item No. 4 is completed across the entire surface prior to applying the protective plaster. The Waterproofing material shall have Specific Gravity: 1.2, Water vapor permeance: 244.48 g/m2/24 hrs, as per IS 7809/Pt 2/1977, Adhesion strength: 2 N/mm2 as per ASTM D 4541: 02. The finished cost to include surface preparation completely as per specification. | Cum | 2072.85 | 2072.85 | 851.12 | False | None | None | False | None | False | 1764244.092 | 0 | 3262736 | 113020 | None | V-2 P.No 110 It.No 12.90 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall
be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) | Cum | 8343.43 | 8343.43 | 3.6 | False | None | None | False | None | False | 30036.348 | 0 | 3262737 | 113020 | None | V-1 P.No 16 IT.No 2.5.1 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork
| Cum | 11911.13 | 11911.13 | 0.28 | False | None | None | False | None | False | 3335.1164 | 0 | 3262738 | 113020 | None | V-3 P.No 3 It.No 1.1A | Loading and Unloading of Stone Boulder/Stone aggregates/ Sand/Kankar/Moorum. (Disposal of 10Km)
| Cum | 167.27 | 167.27 | 286.43 | False | None | None | False | None | False | 47911.1461 | 0 | 3262739 | 113020 | None | V-1 P.No 8 It.No 1.16.3 | Earth work excavation for FOUNDATION by Mechanical means depth upto 1.50m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including cost of explosives, dressing of excavated surfaces, disposing off or levelling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, blasting materials, tools, usage of Machinery & all other appurtenaces required to complete the work.In Hard Rock ( requiring blasting) Depth upto 3 m to 4.5 m
| Cum | 880.93 | 880.93 | 14.91 | False | None | None | False | None | False | 13134.6663 | 0 | 3262740 | 113020 | None | V-1 P.No 8 It.No 1.16.2 | Earth work excavation for FOUNDATION by Mechanical means depth upto 1.50m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including cost of explosives, dressing of excavated surfaces, disposing off or levelling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, blasting materials, tools, usage of Machinery & all other appurtenaces required to complete the work.In Hard Rock ( requiring blasting) Depth upto 1.50m to 3 m
| Cum | 771.9 | 771.9 | 31.95 | False | None | None | False | None | False | 24662.205 | 0 | 3262741 | 113020 | None | V-1 P.No 8 It.No 1.16.1 | Earth work excavation for FOUNDATION by Mechanical means depth upto 1.50m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including cost of explosives, dressing of excavated surfaces, disposing off or levelling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, blasting materials, tools, usage of Machinery & all other appurtenaces required to complete the work.In Hard Rock ( requiring blasting) Depth upto 1.50m
| Cum | 686.41 | 686.41 | 31.95 | False | None | None | False | None | False | 21930.7995 | 0 | 3262742 | 113020 | None | V-1 P.No 9 It.No 1.15.3 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work Depth 3 to 4.5
| Cum | 573.66 | 573.66 | 29.82 | False | None | None | False | None | False | 17106.5412 | 0 | 3262743 | 113020 | None | V-1 P.No 9 It.No1.15.2 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work Depth exceeding 1.5 to 3 | Cum | 526.58 | 526.58 | 63.9 | False | None | None | False | None | False | 33648.462 | 0 | 3262744 | 113020 | None | V-1 P.No 8 It.No 1.15.1 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In ordinary/soft rock without blasting upto 1.5 m depth
| Cum | 449.76 | 449.76 | 63.9 | False | None | None | False | None | False | 28739.664 | 0 | 3262745 | 113020 | None | V-1 P.No 8 It.No 1.14.2 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m to 6M.
| Cum | 144.96 | 144.96 | 104.37 | False | None | None | False | None | False | 15129.4752 | 0 |
| 1718022464000 | 0 | None | None | Buildings | Name plates and Signages | 3363236.0 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3262746 | 113021 | None | Approved Rate | Pharmacy 3D Acrylic Channel letters - 100mm thick - internally lit with LEDs
(GF) | No | 65372.0 | 65372.0 | 4.0 | False | None | None | False | None | False | 261488.0 | 0 | 3262747 | 113021 | None | Approved rate | Emergency 3D Acrylic Channel letters - 100mm thick - internally lit with LEDs
(GF) | No | 147972.0 | 147972.0 | 2.0 | False | None | None | False | None | False | 295944.0 | 0 | 3262748 | 113021 | None | Approved rate | Department Names - 3D 3D 40mm SS Mirror Finish channel letters - Non Lit
(GF) | No | 26550.0 | 26550.0 | 30.0 | False | None | None | False | None | False | 796500.0 | 0 | 3262749 | 113021 | None | Approved Rate | Floor Directory Acid Etching on SS fixed on Acrylic
(GF) | No | 15104.0 | 15104.0 | 3.0 | False | None | None | False | None | False | 45312.0 | 0 | 3262750 | 113021 | None | Approved Rate | Room Identification Signage SS Acid etching
(GF) | No | 1321.6 | 1321.6 | 20.0 | False | None | None | False | None | False | 26432.0 | 0 | 3262751 | 113021 | None | Approved Rate | Perpendicular Signage SS Acid etching stuck on Acrylic
(GF) | No | 2242.0 | 2242.0 | 10.0 | False | None | None | False | None | False | 22420.0 | 0 | 3262752 | 113021 | None | Approved Rate | Nurse Station 3D signage 3D Aluminium Channel Letter
(GF) | No | 9145.0 | 9145.0 | 4.0 | False | None | None | False | None | False | 36580.0 | 0 | 3262753 | 113021 | None | Approved Rate | Ceiling Suspended Direction Signage Aluminum Modular Signage using Aluminum alloy 6063 extrusion with Anodizing (thickness typically to be 30 microns. The integrity to meet international specifications ISO 2143-1981) with life time warranty in normal working conditions. Clear Cover : Clear UV protected 1mm thick Poly carbonate sheet with non Glare/glossy finish. Size - 210 X 700
(GF) | No | 4484.0 | 4484.0 | 10.0 | False | None | None | False | None | False | 44840.0 | 0 | 3262754 | 113021 | None | Approved Rate | Lift Identiciation Acrylic Signage
(GF) | No | 2950.0 | 2950.0 | 6.0 | False | None | None | False | None | False | 17700.0 | 0 | 3262755 | 113021 | None | Approved Rate | Information Signage SS Acid etching
(GF) | No | 9145.0 | 9145.0 | 10.0 | False | None | None | False | None | False | 91450.0 | 0 | 3262756 | 113021 | None | Approved Rate | Bed Numbers Acrylic Signage
(GF) | No | 472.0 | 472.0 | 80.0 | False | None | None | False | None | False | 37760.0 | 0 | 3262757 | 113021 | None | Approved rate | Mandatory Signage A4 5MM Sunboard with vinyl
(GF) | No | 1770.0 | 1770.0 | 10.0 | False | None | None | False | None | False | 17700.0 | 0 | 3262758 | 113021 | None | Approved Rate | Mandatory Signage A0 5MM Sunboard with vinyl
(GF) | No | 2950.0 | 2950.0 | 10.0 | False | None | None | False | None | False | 29500.0 | 0 | 3262759 | 113021 | None | Approved rate | Room Identification Signage SS Acid etching
FIRST & second FLOOR
| No | 1321.6 | 1321.6 | 40.0 | False | None | None | False | None | False | 52864.0 | 0 | 3262760 | 113021 | None | Approved Rate | Nurse Station 3D signage 3D Aluminium Channel Letter
FIRST & second FLOOR | No | 9145.0 | 9145.0 | 8.0 | False | None | None | False | None | False | 73160.0 | 0 | 3262761 | 113021 | None | Approved Rate | Patient Identification Boards Acrylic A4 size inserts
FIRST & second FLOOR | 2 Cmtr | 2950.0 | 2950.0 | 10.0 | False | None | None | False | None | False | 29500.0 | 0 | 3262762 | 113021 | None | Approved Rate | Floor Directory Acid Etching on SS fixed on Acrylic
FIRST & second FLOOR | No | 10030.0 | 10030.0 | 4.0 | False | None | None | False | None | False | 40120.0 | 0 | 3262763 | 113021 | None | Approved rate | Ceiling Suspended Direction Signage Aluminum Modular Signage using Aluminum alloy 6063 extrusion with Anodizing (thickness typically to be 30 microns. The integrity to meet international specifications ISO 2143-1981) with life time warranty in normal working conditions. Clear Cover : Clear UV protected 1mm thick Poly carbonate sheet with non Glare/glossy finish. Size - 210 X 700
FIRST & second FLOOR | No | 4484.0 | 4484.0 | 20.0 | False | None | None | False | None | False | 89680.0 | 0 | 3262764 | 113021 | None | Approved Rate | Perpendicular Sigange SS Acid etching stuck on Acrylic
FIRST & second FLOOR | No | 2242.0 | 2242.0 | 20.0 | False | None | None | False | None | False | 44840.0 | 0 | 3262765 | 113021 | None | Approved Rate | Department 3D Signage 3D 40mm SS Mirror Finish channel letters - Non Lit
FIRST & second FLOOR | No | 26550.0 | 26550.0 | 20.0 | False | None | None | False | None | False | 531000.0 | 0 | 3262766 | 113021 | None | Approved Rate | Lift Identiciation Acrylic Signage
FIRST & second FLOOR | No | 2950.0 | 2950.0 | 12.0 | False | None | None | False | None | False | 35400.0 | 0 | 3262767 | 113021 | None | Approved Rate | Information Signage SS Acid etching
FIRST & second FLOOR | No | 8850.0 | 8850.0 | 20.0 | False | None | None | False | None | False | 177000.0 | 0 | 3262768 | 113021 | None | Approved Rate | Bed Numbers Acrylic Signage
FIRST & second FLOOR | No | 472.0 | 472.0 | 110.0 | False | None | None | False | None | False | 51920.0 | 0 | 3262769 | 113021 | None | Approved Rate | Mandatory Signage A4 5MM Sunboard with vinyl
FIRST & second FLOOR | No | 1770.0 | 1770.0 | 20.0 | False | None | None | False | None | False | 35400.0 | 0 | 3262770 | 113021 | None | Approved Rate | Mandatory Signage A0 5MM Sunboard with vinyl
FIRST & second FLOOR | No | 2950.0 | 2950.0 | 20.0 | False | None | None | False | None | False | 59000.0 | 0 | 3262771 | 113021 | None | Approved Rate | BUILDING SIGNAGE Aluminum Modular Signage using Aluminum alloy 6063 extrusion with Anodizing (thickness typically to be 30 microns. The integrity to meet international specifications ISO 2143-1981) with life time warranty in normal working conditions. Clear Cover : Clear UV protected 1mm thick Poly carbonate sheet with non Glare/glossy finish. Size - 210 X 700. ON THE BUILDING EXTERNAL
| No | 419726.0 | 419726.0 | 1.0 | False | None | None | False | None | False | 419726.0 | 0 |
| 1718022464000 | 0 | None | None | Buildings | ETP | 1020700.0 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3262772 | 113022 | None | MARKET RATE | Modular - ETP : Consists of MS fabricated ETP plant, effluent transfer pumps, effluent agitator, sludge disposal pump, chemical dosing pumps, MCC panel complete
| No | 1020700.0 | 1020700.0 | 1.0 | False | None | None | False | None | False | 1020700.0 | 0 |
| 1718022464000 | 0 | None | None | Buildings | BOREWELL | 647384.97 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3262773 | 113023 | None | V-5 P.No 140 It.No 12.4 | Geophysical investigation at site for sinking borewells for Providing drinking water to the habitation either through the Hand Pump MWS or P.W.S.S, by vertical electrical sounding by adopting Venner or Schlumbergers's method, including reconnaissance survey of geological formation. Geophysical investigation of existing ground water in the vicinity, its quality, quantity and acceptability of the users, indic ting the location of the site, recommended depth of casing pipe required seal the top unconsolidated formation including an extra depth of 1.0 metre in consolidated formation for proper seating of casin pipe, depth of drilling required to cover full depth of aquifer proposed to be tapped, probable yield and other information required including transportation of instruments and accessories to work site, engaging techn al personal and labour required etc. NOTE: 1) Additional rate on item 1&2 is allowed for drilling in over burden and fixing Casing pipes beyond 20 M (for fixing Casing pipes only) a) Above M and upto 30 M - 15%,
b) Above 30 M - 30% (Measurement of overburden is restricted to the depth of casing pipe fixed excluding initial depth of 20M and projection above ground level). 2) A sum of R . 100/- is to be deducted for Dry Borewell towards yield test. tc. complete.
| Each | 6551.83 | 6551.83 | 1.0 | False | None | None | False | None | False | 6551.83 | 0 | 3262774 | 113023 | None | V-5 P.No 139 It.No 12.11 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth)
Borewell depth of 0 to 50 Mtrs
| Rmtr | 458.43 | 458.43 | 50.0 | False | None | None | False | None | False | 22921.5 | 0 | 3262775 | 113023 | None | V-5 P.No 139 It.No 12.1.2 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth)
Borewell depth of 50 to 100 Mtrs
| Rmtr | 574.9 | 574.9 | 50.0 | False | None | None | False | None | False | 28745.0 | 0 | 3262776 | 113023 | None | V-5 P.No 139 It.No 12.1.3 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth)
Borewell depth of 100 to 150 Mtrs
| Rmtr | 610.83 | 610.83 | 50.0 | False | None | None | False | None | False | 30541.5 | 0 | 3262777 | 113023 | None | V-5 P.No 139 It.No 12.1.4 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth)
Borewell depth of 150 to 200 Mtrs
| Rmtr | 708.71 | 708.71 | 50.0 | False | None | None | False | None | False | 35435.5 | 0 | 3262778 | 113023 | None | V-5 P.No 139 It.No 12.1.5 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth)
Borewell depth of 200 to 250 Mtrs
| Rmtr | 831.37 | 831.37 | 50.0 | False | None | None | False | None | False | 41568.5 | 0 | 3262779 | 113023 | None | V-5 P.No 139 It.No 12.1.6 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth)
Borewell depth of 250 to 300 Mtrs
| Rmtr | 916.86 | 916.86 | 50.0 | False | None | None | False | None | False | 45843.0 | 0 | 3262780 | 113023 | None | V-5 P.No 139 It.No 12.1.7 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth)
Borewell depth of 300 to 350 Mtrs
| Rmtr | 1075.45 | 1075.45 | 50.0 | False | None | None | False | None | False | 53772.5 | 0 | 3262781 | 113023 | None | V-5 P.No 143 It.No 12.32 | Supply of ISI mark 175mm nominal bore,plain and steel casing pipe grade of steel Fe 410 of wall thickness conforming to IS 4270-2001 nd latest ammendments, electrical resistance welded steel tubes, terial and conforming to IS 1387-1993 and manufactured by basic open hearth electric or basic oxygen process in random length of 5-7m both ends.threaded conforming to IS 554-1985 one end fixe with socket conforming to IS 4270-2001 and the other end with screwed pipes all shall be responsibaly free from defects. The tubes shall be responsible straight end should be with ISI marking weighing 25.10kg/m.prices include Collar-Medium duty.
| Rmtr | 2394.99 | 2394.99 | 35.0 | False | None | None | False | None | False | 83824.65 | 0 | 3262782 | 113023 | None | V-5 P.No 155 It.No 13.28 | Supply and delivery at site 50mm(2”) dia heavy duty unplasticized PVC Column pipes with heavy duty collars,rubber profile ring,vibration control profile ring,freezing and turbulence free leak proof EPDM ring with ISI mark with its latest amendments.
| Rmtr | 681.45 | 681.45 | 200.0 | False | None | None | False | None | False | 136290.0 | 0 | 3262783 | 113023 | None | V-5 P.No 143 It.No 12.33 | Providing and fixing MS casing collars per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thic ness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments.
| No | 185.85 | 185.85 | 1.0 | False | None | None | False | None | False | 185.85 | 0 | 3262784 | 113023 | None | V-5 P.No 143 It.No 12.34 | Providing and laying at site of wor MS asing caps as per IS 1239 (part- II) 1982 with all latest amendm nts if any for any dia. The thickness of plate used for covering one e shall be 3mm (minimum). The dimensions of caps and olars shall be strictly as per IS 1239 (Part-II) 1982 with all mendments including cost of material and labour charges for fixing, if a y etc. complete with all lead and lifts and as directed by the Engineer in charge.
| No | 203.2 | 203.2 | 1.0 | False | None | None | False | None | False | 203.2 | 0 | 3262785 | 113023 | None | P.No 95 18-19 SR It.No 13.81.3 | Providing NP/CP 50mm dia Waste Unions conforming to ISI specifications and fixing them in position as per directions (Rates includes cost of materials fixtures and conveyance to work spot etc complete)
| No | 260.19 | 260.19 | 1.0 | False | None | None | False | None | False | 260.19 | 0 | 3262786 | 113023 | None | V-5 P.No 152 It.No 13.13.6 | Providing Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications, to work site as per necessary ammendments and instructions of engineer incharge of work. For HP etc Complete.5.00 HP - 90 LPM @ 110 m = 15 STG Outlet Dia - 2.00"
| Each | 39817.74 | 39817.74 | 1.0 | False | None | None | False | None | False | 39817.74 | 0 | 3262787 | 113023 | None | V-5 P.No 155 It.No 13.23.2 | Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protectionsuitable for thepumpdescribedabove 1 no Indoor type NOTE: 1) DOL- Direct Online Starter
2) S-D- Star Delta Starter etc. complete.3 to 6 HP pumps | Each | 11832.45 | 11832.45 | 1.0 | False | None | None | False | None | False | 11832.45 | 0 | 3262788 | 113023 | None | V-5 P.No 155 It.No 13.29 | Supply and delivery at site 50mm(2”) dia heavy duty CI adopter set complete suitable for uPVC Column pipes for Submersible pumpsets
| Set | 1920.45 | 1920.45 | 1.0 | False | None | None | False | None | False | 1920.45 | 0 | 3262789 | 113023 | None | V-5 P.No 155 It.No 13 | Supply and delivery at site Stringing of heavy duty Naylone/PP rope with ISI etc complete suitable for Single phase Pumpsets.
| Job | 49.56 | 49.56 | 100.0 | False | None | None | False | None | False | 4956.0 | 0 | 3262790 | 113023 | None | V-5 P.No 156 It.No 13.32 | Labour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all items including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges,tools and equipments etc., involved in the job as per specifications, with necessary tests as per specifications, with testing of as per instructions of engineer incharge of work.
| Job | 8053.5 | 8053.5 | 1.0 | False | None | None | False | None | False | 8053.5 | 0 | 3262791 | 113023 | None | V-5 P.No 156 It.No 13.33 | Labour charges for erection of indoor type panel board and meter board units with all necessary materials and labour tools and equipments including cement concrete for foundation/bed etc,complete as per specification, with testing of as per instructions of engineer incharge of work.
| Job | 1672.65 | 1672.65 | 1.0 | False | None | None | False | None | False | 1672.65 | 0 | 3262792 | 113023 | None | V-6 P.No 7 It.No 2.6.2 | Supplying and drawing 3 core flat PVC sheathed submersible pump cable manufactured with electrolytic grade copper with flexible copper with low resistance conductor confirming to13:8130-1984 and virgin grade PVC insulation and powder coating extruded PVC sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990.3C x 4 mm2
| Rmtr | 208.15 | 208.15 | 275.0 | False | None | None | False | None | False | 57241.25 | 0 | 3262793 | 113023 | None | V-6 P.No 20 It.No 5.42.2 | Fabricating supplying and mounting MS box made out .SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. 16SWG
| Sq CM | 0.53 | 0.53 | 30000.0 | False | None | None | False | None | False | 15900.0 | 0 | 3262794 | 113023 | None | V-6 P.No 21 It.No 5.44.4 | Supply and Installation / Fixing / Provision of Outdoor type Thermoplastic Modular Panel enclosure with transparent Polycarbonate Lid, shock proof, IP65 (Weather Proof), rust proof, dust proof, water proof, corrosion proof having internally Embedded gasket on both lid and flap suitable to fix Single Phase / Three Phase Energy Meter in suitable base plate and having a provision for Fuse / MCB cut-out with suitable transparent hinged flap opening for operating MCB along with complete tamper proof SEALING facility. 600mmx600mmx170mm.
| Each | 17990.28 | 17990.28 | 1.0 | False | None | None | False | None | False | 17990.28 | 0 | 3262795 | 113023 | None | V-6 P.No 14 It.No 5.6.6 | Supply and fixing polished wood board made of not less than 15mm thick plank on both sides of not more than 2 pieces and fixing the same to the wall using tapered inverted wooden plugs screws.20" x 20" x 2.5"
| Each | 404.08 | 404.08 | 1.0 | False | None | None | False | None | False | 404.08 | 0 | 3262796 | 113023 | None | V-6 P.No 17 It.No 5.18.1 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.6-32 A SP
| Each | 514.19 | 514.19 | 1.0 | False | None | None | False | None | False | 514.19 | 0 | 3262797 | 113023 | None | V-6 P.no 57 It.No 13.18.1 | Fixing of . A TPST / change over switch / Contactor along with neutral link with screws, bolts, nuts and wiring using required capacity wires and circuit labelling.15A to 63A TPST
| Each | 344.44 | 344.44 | 1.0 | False | None | None | False | None | False | 344.44 | 0 | 3262798 | 113023 | None | V-6 P.No 19 It.No 5.37 | Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 V grade, for power factor improvement of rotating machineries like induction motor.
| Kvar | 594.72 | 594.72 | 1.0 | False | None | None | False | None | False | 594.72 | 0 |
| 1718022464000 | 0 | None | None | Buildings | BITUMINOUS ROAD | 12269662.03 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3262799 | 113024 | None | V-3 P.No 9 P.No 2.5A | Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness.By Mechanical Means using Dozer.A In area of light jungle
6.0 mt Road
| Sqm | 486.93 | 486.93 | 66.7 | False | None | None | False | None | False | 32478.231 | 0 | 3262800 | 113024 | None | V-1 P.No 8 It.No 1.12 | Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depth
6.0 mt Road
| Cum | 117.71 | 117.71 | 2001.0 | False | None | None | False | None | False | 235537.71 | 0 | 3262801 | 113024 | None | V-1 P.No 7 It.No 1.4.1 | Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m
| Cum | 299.84 | 299.84 | 2001.0 | False | None | None | False | None | False | 599979.84 | 0 | 3262802 | 113024 | None | V-3 P.No 17 It.No 3.1 | Removal of Unserviceable Soil with Disposal upto a suitable distance as directed by the Engineer incharge of work
| Cum | 105.32 | 105.32 | 400.2 | False | None | None | False | None | False | 42149.064 | 0 | 3262803 | 113024 | None | V-3 P.No 25 It.No 4.11 A | Making 50 mm x 50 mm furrows, 25mm/ 50mm deep, 45 degrees to the center line of the road and at one metre interval in the existing thin bituminous wearing coarse including sweeping and disposal of excavated material.25 mm deep furrow cutting
| Sqm | 9.91 | 9.91 | 4002.0 | False | None | None | False | None | False | 39659.82 | 0 | 3262804 | 113024 | None | V-3 P.No 17 It.No 3.7 | Compacting original ground supporting embankment-Loosening, leveling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Table 300-2 for embankment construction.
| Cum | 130.1 | 130.1 | 600.3 | False | None | None | False | None | False | 78099.03 | 0 | 3262805 | 113024 | None | V-1 P.No 7 It.No 1.8 | Construction of Embankment by excavating the available approved Gravel/ Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work.
| Cum | 587.29 | 587.29 | 6003.0 | False | None | None | False | None | False | 3525501.87 | 0 | 3262806 | 113024 | None | V-3 P.No 23 It.No 4.2 V | Construction of Granular Sub-Base of required grading as per design spreading in uniform layers with motor grader on prepared surface mixing by mix in place method with front end loader at OMC and compacting with vibratory roller to achieve the desired density, complete as per clause 401 .For Grading -V Material
| Cum | 3081.39 | 3081.39 | 400.2 | False | None | None | False | None | False | 1233172.278 | 0 | 3262807 | 113024 | None | V-3 P.no 26 It.No 4.17 | Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver/grader in sub-base / base course on well prepared surface andcompactingwithvibratoryrollertoachievethedesireddensity.
| Cum | 3170.6 | 3170.6 | 400.2 | False | None | None | False | None | False | 1268874.12 | 0 | 3262808 | 113024 | None | V-3 P.No 31 It.No 5.1 | Providing and applying primer coat with SS1 grade Bitumen Emulsion on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.70 kg/m2 using mechanical means.
| Sqm | 50.8 | 50.8 | 4002.0 | False | None | None | False | None | False | 203301.6 | 0 | 3262809 | 113024 | None | V-3 P.No 31 It.No 5.3 | Providing and applying tack coat with RS1 Bituminous Emulsion using emulsion pressure distributor at the rate of 0.20 kg/m2 on the prepared bituminous surface cleaned with mechanical broom
| Sqm | 14.87 | 14.87 | 4002.0 | False | None | None | False | None | False | 59509.74 | 0 | 3262810 | 113024 | None | V-3 P.No 29 It.No 5.6 A | Providing and laying Bituminous Macadam with 120 TPH capacity hot mix plant batch type using crushed aggregates of specified grading premixed with bituminous binder VG- 40 @ 3.3% by weight of mix, transported to site, laid over a previously prepared surface with mechanical paver finisher to the required grade, level and alignment and rolled as per clauses 501.6 and 501.7 to achieve the desired compaction | Cum | 9337.1 | 9337.1 | 300.15 | False | None | None | False | None | False | 2802530.565 | 0 | 3262811 | 113024 | None | V-3 P.No 43 It.no 5.31 | Providing and laying Semi Dense Bituminous Concrete with 40/60 TPH capacity hot mix plant batch type using crushed aggregates of specified grading premixed with bituminous binder VG-30 @ 5% by weight of mix and filler, transported to site, laid over a previously prepared surface with mechanical paver finisher to the required grade, level and alignment and rolled as per MoRTH V revision.
| Cum | 12578.33 | 12578.33 | 100.05 | False | None | None | False | None | False | 1258461.9165 | 0 | 3262812 | 113024 | None | V-1 P.no 15 It.No 2.1.3 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates. Including FormWork
| Cum | 7420.37 | 7420.37 | 40.02 | False | None | None | False | None | False | 296963.2074 | 0 | 3262813 | 113024 | None | V-3 P.No 74 It.No 8.42.2 | Supplying and fixing M15 grade precast cement concrete Kerb stones for Roadway, Sidewalls and gutters fixed with CM 1:3 fixed and finsihed in line as per direction of Engineer in charge. (The cost of PCC shall be paid extra)600 x 200 x 100 mm Kerb Stone
| Rmtr | 309.75 | 309.75 | 1334.0 | False | None | None | False | None | False | 413206.5 | 0 | 3262814 | 113024 | None | V-3 P.No 27 It.No 4.19 | Construction of Median and Island above road level with approved material deposited at site from roadway cutting and excavation for drain and foundation of other structures, spread, graded and compacted as per clause 408
| Cum | 454.71 | 454.71 | 180.09 | False | None | None | False | None | False | 81888.7239 | 0 | 3262815 | 113024 | None | V-3 P.No 66 It.No 8.10 | Painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfaces.
| Sqm | 105.32 | 105.32 | 933.8 | False | None | None | False | None | False | 98347.816 | 0 |
| 1718022464000 | 0 | None | None | Buildings | DRAIN | 8028382.4 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3262816 | 113025 | None | V-3 P.no 7 It.No 2.5A | Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness.By Mechanical Means using Dozer.A In area of light jungle
| Cum | 486.9 | 486.9 | 4.0 | False | None | None | False | None | False | 1947.6 | 0 | 3262817 | 113025 | None | V-1 P.no 8 It.No 1.14.1 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work 1.14.1 In all kinds of soils Depth upto 3 m.
| Cum | 126.4 | 126.4 | 1280.64 | False | None | None | False | None | False | 161872.896 | 0 | 3262818 | 113025 | None | V-1 P.no 8 It.no 1.15.1 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In ordinary/soft rock without blasting upto 1.5 m depth
| Cum | 449.8 | 449.8 | 320.16 | False | None | None | False | None | False | 144007.968 | 0 | 3262819 | 113025 | None | V-3 P.No 3 It.No 1.1A | Loading and Unloading of Stone Boulder/Stone aggregates/ Sand/Kankar/Moorum.
For 5 KM lead = 2.5 x 1.28 x 5 + loading and Unloading charges =68 = 84.00/cum
| Cum | 167.3 | 167.3 | 1600.8 | False | None | None | False | None | False | 267813.84 | 0 | 3262820 | 113025 | None | V-1 P.No 15 It.No 2.1.3 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates. Including FormWork
| Cum | 7420.4 | 7420.4 | 133.4 | False | None | None | False | None | False | 989881.36 | 0 | 3262821 | 113025 | None | V-1 P.No 16 It.No 2.5.1 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork
Base slab (VENT PORTION)
| Cum | 8625.3 | 8625.3 | 120.0 | False | None | None | False | None | False | 1035036.0 | 0 | 3262822 | 113025 | None | V-1 P.no 16 It.No 2.5.1 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork
Side wall
| Cum | 11089.7 | 11089.7 | 160.08 | False | None | None | False | None | False | 1775239.176 | 0 | 3262823 | 113025 | None | V-2 P.No 176 It.No 17.12 | Providing and laying 100mm thick pre-cast cover slabs over drains & Rain pit of width not exceeding 800 mm using M20 concrete reinforced with Micro Alloyed High carbon steel with 3mm - 3ply wired steel @ 2.00 kg/m2, slabs jointed in CM 1:3 proportion and nicely finished Including providing holes in the Cover slabs wherever necessary for easy drainage of surface water including of labour, materials, scaffolding, usage of machinery, curing, lead and lift charges etc, Complete.
| Sqm | 1149.8 | 1149.8 | 1200.6 | False | None | None | False | None | False | 1380449.88 | 0 | 3262824 | 113025 | None | V-1 P.No 18 It.No 2.11 h | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.All other type of structures
| Tonne | 97894.6 | 97894.6 | 23.21 | False | None | None | False | None | False | 2272133.666 | 0 |
| 1718022464000 | 0 | None | None | Buildings | LANDSCAPE | 1295731.81 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3262825 | 113026 | None | V-8 P.No 49 It.No 12.10 A | SCRAPPINGANDREMOVINGTOPSOIL:-Scrappingtheareabyremoving0.15msoilandremovingofunwantedplants,grassalongwithroots.25kminitialtransport,including lead, lift loading and unloading charges. (1x1x0.15mt)
Lawn area
| Cum | 52.93 | 52.93 | 242.76 | False | None | None | False | None | False | 12849.2868 | 0 | 3262826 | 113026 | None | V-8 P.No 49 It.No 12.10 B | 1STDIGGING:-Diggingoftheareafordevelopinglawnincludingremovingweeds,debris if any and breaking of clumps, watering etc. (1x1x0.45mt)
Lawn area
| Cum | 94.14 | 94.14 | 728.28 | False | None | None | False | None | False | 68560.2792 | 0 | 3262827 | 113026 | None | V-8 P.No 49 It.No 12.10 C | 2NDDIGGING:-Diggingofsoilbyremovinggrassetcifanyandlevellingofthesoiletc . (1x1x0.45mt)
Lawn area
| Cum | 47.07 | 47.07 | 728.28 | False | None | None | False | None | False | 34280.1396 | 0 | 3262828 | 113026 | None | V-8 P.No 49 It.No 12.10 D | procurement of quality red earth/soil and heap around pit (1x1x0.15mt)
Lawn area
| Cum | 89.69 | 89.69 | 242.76 | False | None | None | False | None | False | 21773.1444 | 0 | 3262829 | 113026 | None | V-8 P.No 49 It.No 12.10 E | Supplyofinputssuchassand,FYM,Redearthin1:3:6ratio.mixingandspreadingthe mixture to 7.50cm thickness wherever required.* Red soil-0.0075cum, *Farm Yard manure-0.0225cum, * Sand-0.045cum
| Cum | 134.93 | 134.93 | 121.38 | False | None | None | False | None | False | 16377.8034 | 0 | 3262830 | 113026 | None | As per market rate by Quotation | Supply of Fertiliser-Super Phosphate -50 gram, Neem oilcake -250gram, Bone meal-250gram, Potash-50gram,Furadan-25gram,Ammonium Sulphate-100gram,Chlorophyriphos-0.05 mili ltr.(Total 750 Gram) per kg 22 rs/-
| Sqm | 21.06 | 21.06 | 1618.4 | False | None | None | False | None | False | 34083.504 | 0 | 3262831 | 113026 | None | V-8 P.No 49 It.No 12.10 G a | Procurement of quality lawn grass Bermuda Grass
Bermuda Grass turf
| Sqm | 123.9 | 123.9 | 200.0 | False | None | None | False | None | False | 24780.0 | 0 | 3262832 | 113026 | None | V-8 P.No 49 It.No 12.10 G c | Procurement of quality lawn grass Mexican Grass
Mexican grass turf
| Sqm | 247.8 | 247.8 | 200.0 | False | None | None | False | None | False | 49560.0 | 0 | 3262833 | 113026 | None | V-8 P.No 49 It.No 12.10 G d | Procurement of quality lawn grass Korean Grass
Korean Grass turf
| Sqm | 247.8 | 247.8 | 200.0 | False | None | None | False | None | False | 49560.0 | 0 | 3262834 | 113026 | None | V-8 P.No 49 It.No 12.10 G e | Procurement of quality lawn grass Phasphalam Grass
Phasphalam Grass turf
| Sqm | 185.85 | 185.85 | 200.0 | False | None | None | False | None | False | 37170.0 | 0 | 3262835 | 113026 | None | V-8 P.No 49 It.No 12.10 G i | Procurement of quality lawn grass Ooty kiku Grass
Ooty kiku Grass turf
| Sqm | 123.9 | 123.9 | 200.0 | False | None | None | False | None | False | 24780.0 | 0 | 3262836 | 113026 | None | V-8 P.No 49 It.No 12.10 H, I,a | Labour Charges mixingInputsasperprescribedproportionandquantityandspreading,applyingfertilizers,digging,levelling,anddibblingwithlawngrassataspacingof5cmx5cm& as per the direction of the Officer in charge of the work.
Lawn development cost
Bermuda Grass turf
| Sqm | 600.92 | 600.92 | 200.0 | False | None | None | False | None | False | 120184.0 | 0 | 3262837 | 113026 | None | V-8 P.No 49 It.No 12.10 H,I,C | Labour Charges mixingInputsasperprescribedproportionandquantityandspreading,applyingfertilizers,digging,levelling,anddibblingwithlawngrassataspacingof5cmx5cm& as per the direction of the Officer in charge of the work.
Lawn development cost
Mexican grass turf
| Sqm | 724.82 | 724.82 | 200.0 | False | None | None | False | None | False | 144964.0 | 0 | 3262838 | 113026 | None | V-8 P.no 49 It.No 12.10 H,I,D | Labour Charges mixingInputsasperprescribedproportionandquantityandspreading,applyingfertilizers,digging,levelling,anddibblingwithlawngrassataspacingof5cmx5cm& as per the direction of the Officer in charge of the work.
Lawn development cost
Korean Grass turf
| Sqm | 724.82 | 724.82 | 200.0 | False | None | None | False | None | False | 144964.0 | 0 | 3262839 | 113026 | None | V-8 P.No 49 It.No12.10 H,i,e | Labour Charges mixingInputsasperprescribedproportionandquantityandspreading,applyingfertilizers,digging,levelling,anddibblingwithlawngrassataspacingof5cmx5cm& as per the direction of the Officer in charge of the work.
Lawn development cost
Phasphalam Grass turf
| Sqm | 681.45 | 681.45 | 200.0 | False | None | None | False | None | False | 136290.0 | 0 | 3262840 | 113026 | None | V-8 P.No 49 It.No 12.10 H,i,i | Labour Charges mixingInputsasperprescribedproportionandquantityandspreading,applyingfertilizers,digging,levelling,anddibblingwithlawngrassataspacingof5cmx5cm& as per the direction of the Officer in charge of the work.
Lawn development cost
Ooty kiku Grass turf
| Sqm | 619.5 | 619.5 | 200.0 | False | None | None | False | None | False | 123900.0 | 0 | 3262841 | 113026 | None | V-8 P.No 50 It.No 12.11(a) | Upto 8000.0 m2 (2.0 Acres)-WORK TO BE UNDER TAKEN DURING MAINTENANCE:-Watering : The plants and lawns in the garden should be watered frequently as required looking to the climate, soil and plant conditions: If sprinklers are made available, it can be used other wise hose pipe can be used for watering, problems regarding pipe line damage during watering/maintenance should be repaired and taken care.
Weeding : Weeding has to be done regularly in the entire garden area including extra weed growth in the pathways and other remaining areas in the park. Weeding should be done regularly once in a fortnight and the weeds collected should be used for preparing manure or it should be disposed from the garden appropriately.
Sweeping : Sweeping of the garden area has to be done daily. The pathways, entire garden area should be swept and kept free of fallen leanves, branches, flowers, dust etc., and should be made use for the public. Dust bins in the garden area should be emptied and disposed properly and regularly. Any dead rodent, pets or animals are founds should be removed immediately and the garden spaces should be free from foul smell. Gazeboo, Chairs and Other Adomments should be cleaned daily.
Maintenance of Shrubs, Edges, Ground cover and other area by regular pruning, digging so as to maintain the garden aesthetically.Lawn moving shloud be done regularly every fortnight.Digging of soil around plants in the garden, should be carried out. Soil basins should be prepared around the hedges/ edges/ trees/ shrubs/ ground covers by digging the soil so as to maintain retention of water. This should be done before and after monsoon.
Pruning of plants in the garden, such as the Hedges, Trees, Shrubs, Ground cover plants, Topiary plants, Rose plants etc., should be carried out as and when required and as per the directions of officer in-charge of work.
Transportation of plastic and other materials should be removed from the garden, must be taken care. The swept leaf materials only should be used for preparation of compost manure in the garden itself and the compost manure should be used in the garden. All dead plants, branches and other waste matirials should be removed regularly and transported outside the garden. in the garden area dried leaves and other waste materials should be regularly removed from the garden at the risk of contractors. | Sqm/M | 11.15 | 11.15 | 1618.4 | False | None | None | False | None | False | 18045.16 | 0 | 3262842 | 113026 | None | V-8 P.no 49 It.No 12.2 (b) | Planting of trees-Digging pits of size 0.75 x 0.75x 0.75m, filling 50% of the pit with top soil and remaining 50% of pit with 1:2:3 proportion ofsand (0.035cum) FYM (0.070cum) Red earth (0.105 cum) and planting of well grown tree saplings (excluding cost of plants)
| No | 408.87 | 408.87 | 150.0 | False | None | None | False | None | False | 61330.5 | 0 | 3262843 | 113026 | None | Approved Rate | Supply of decorative Trees such as Pongamia, Ceasalpinia, Lagerstromia, Bauhunia, Golden melauluca, Tabebuia Rosea, Jacaranda etc
| No | 767.0 | 767.0 | 100.0 | False | None | None | False | None | False | 76700.0 | 0 | 3262844 | 113026 | None | Approved Rate | Supply of Palm trees/accent trees such as
Wodyetia Bifurcata 2.5 mtrs ht
| No | 2360.0 | 2360.0 | 10.0 | False | None | None | False | None | False | 23600.0 | 0 | 3262845 | 113026 | None | Approved Rate | Supply of Palm trees/accent trees such as
Areca Leutescens 1.5 mtrs ht
| No | 590.0 | 590.0 | 10.0 | False | None | None | False | None | False | 5900.0 | 0 | 3262846 | 113026 | None | Approved Rate | Supply of Palm trees/accent trees such as
Plumeria Alba 1.8 mtrs
| No | 2950.0 | 2950.0 | 10.0 | False | None | None | False | None | False | 29500.0 | 0 | 3262847 | 113026 | None | Approved Rate | Supply of Palm trees/accent trees such as
Plumeria Rubra 1.8 mtrs
| No | 2950.0 | 2950.0 | 10.0 | False | None | None | False | None | False | 29500.0 | 0 | 3262848 | 113026 | None | Approved Rate | Supply of Palm trees/accent trees such as
Polyatia Ashoka 1.5 mtrs
| No | 708.0 | 708.0 | 10.0 | False | None | None | False | None | False | 7080.0 | 0 |
| 1718022464000 | 0 | None | None | Buildings | Demolition of Old MCH Building | 36740449.65 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3262849 | 113027 | None | V-2p187itm19.3 | Demolishing R.C.C. work manually/ by mechanical means including stack- ing of steel bars and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge. | Cum | 3005.81 | 3005.81 | 7484.34 | False | None | None | False | None | False | 22496504.0154 | 0 | 3262850 | 113027 | None | V-2p187itm19.7.1 | Demolishing brick work manually/ by mechanical means including stack- ing of serviceable material and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge. | Cum | 597.2 | 597.2 | 6630.62 | False | None | None | False | None | False | 3959806.264 | 0 | 3262851 | 113027 | None | V-2p187itm19.9.2 | Demolishing stone rubble masonry manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer- in-charge. In cement mortar | Cum | 2086.48 | 2086.48 | 3016.44 | False | None | None | False | None | False | 6293741.7312 | 0 | 3262852 | 113027 | None | V-2p164itm19.13.1 | Taking out doors, windows and clerestory window shutters (steel or wood) including stacking to the appropriate disposal area as per direction of Engineer-in-charge.Of area 3 m² and below | Sqm | 116.47 | 116.47 | 3919.86 | False | None | None | False | None | False | 456546.0942 | 0 | 3262853 | 113027 | None | V-3p13itm2.27 | Removal of telephone / Electric poles including excavation and dismantling of foundation concrete and lines under the supervision of concerned department, disposal with all lifts and lead and stacking the serviceable and unserviceable material separately
| Nos | 420.02 | 420.02 | 30.0 | False | None | None | False | None | False | 12600.6 | 0 | 3262854 | 113027 | None | V-3p3itm1.1A | Loading and Unloading of Stone Boulder/Stone aggregates/ Sand/Kankar/Moorum. (Disposal of 30Km) | Cum | 167.27 | 167.27 | 21051.3 | False | None | None | False | None | False | 3521250.951 | 0 | 3262855 | 113027 | None | V-2pA-27itm508 | Mathi/Nandi Wood Obtained from Dismantling of Windows PWD Common SR 2023-24 Volume-2 Item No. 508 Page No. A-27 | Cum | 35293.68 | 35293.68 | 105.09 | False | None | None | True | 35293.6 | False | 3709012.8312 | 0 | 3262856 | 113027 | None | V-2p28itm524 | Mild Steel Round Bars 12mm dia and below Obtained from Dismantling of Windows PWD Common SR 2023-24 Volume-2 Item No. 524 Page No. A-28 | Quintal | 2438.18 | 2438.18 | 545.1 | False | None | None | True | 2438.1 | False | 1329051.918 | 0 | 3262857 | 113027 | None | V-1pA-40itm72 | Supplying of Mild Steel Bars | Tonne | 22384.72 | 22384.72 | 447.3 | False | None | None | True | 22384.7 | False | 10012685.256 | 0 | 3262858 | 113027 | None | V-3pA-12itm96 | Random Rubble Stone Obtained from Dismantling of Building Foundation PWD Common SR 2023-24 Volume-3 Item No. 84 Page No. A-12Random Rubble Stone Obtained from Dismantling of Building Foundation PWD Common SR 2023-24 Volume-3 Item No. 84 Page No. A-12 | Cum | 2397.81 | 2397.81 | 2047.68 | False | None | None | True | 2397.8 | False | 4909947.5808 | 0 | 3262859 | 113027 | None | V-1pA-40itm79.0 | Size Stone 200x200x230mm Obtained from Dismantling of Building Foundation & Wall PWD Common SR 2023-24 Volume-1 Item No. 79 Page No. A-40 | Each | 5.59 | 5.59 | 166930.0 | False | None | None | True | 5.59 | False | 933138.7 | 0 |
| 1718022464000 | 0 | None | None | Buildings | Consultancy Charges For Architectural, Structural, & Dpr Charges | 15576685.0 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3262860 | 113028 | None | DATA RATE | The Tenderer (agency) should arrange to obtain (get), detailed Architecturaldrawings and elevations, Structural designs and drawings including Soil exploration & proofchecking by IISC /IIT/NIT/any Engineering college only as decided by the Department and the same has to be furnished to the Department for approval and providing consultancy for Architectural designs & drawings, elevation, 3D view, Internal and External Electrical services including electrical infrastructure , Lifts, CCTV/Net working system interior layout and liaison with other department and approval of pollution control board and allied works etc., and any other drawings related to this project (This item is included in schedule B as a item) and 6 sets of as built drawings should be submitted to the employer. The Consultancy Fees which is included as an item in schedule B shall be paid on prorate basis of the main work or by negotiation with the employer. - - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | LS | 15576685.0 | 15576685.0 | 1.0 | False | None | None | False | None | False | 15576685.0 | 0 |
| 1718022464000 | 0 | None | None | Buildings | Internal Electrification | 41258943.03 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3262861 | 113029 | None | Chapter-2 P.No 5 It.No 2.2.1 | POINT WIRING USING COPPER WIRE WITHOUT SWITCH
Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.
point wiring using class A Materials
Short point upto 3 mts from tapping point to out let via switch box
| Point | 333.29 | 333.29 | 180.0 | False | None | None | False | None | False | 59992.2 | 0 | 3262862 | 113029 | None | Chapter-2 P.No 5 It.No 2.2.2 | POINT WIRING USING COPPER WIRE WITHOUT SWITCH
Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.
Medium point above 3 mts upto 6mts from tapping point to outlet via switch box
| Point | 469.58 | 469.58 | 248.0 | False | None | None | False | None | False | 116455.84 | 0 | 3262863 | 113029 | None | Chapter-2 P.No 5 It.No 2.2.3 | POINT WIRING USING COPPER WIRE WITHOUT SWITCH
Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.
Long point above 6 mts upto 10 mts from tapping point to outlet via switch box
| Point | 687.65 | 687.65 | 964.0 | False | None | None | False | None | False | 662894.6 | 0 | 3262864 | 113029 | None | Chapter-2 P.No 5 It.No 2.2.4 | POINT WIRING USING COPPER WIRE WITHOUT SWITCH
Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.
Two outlet in a row above 3mts upto 6 mts from tapping point to outlet via switches
| Point | 838.8 | 838.8 | 336.0 | False | None | None | False | None | False | 281836.8 | 0 | 3262865 | 113029 | None | Chapter-2 P.No 5 It.No 2.2.5 | POINT WIRING USING COPPER WIRE WITHOUT SWITCH
Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.
point wiring using class A Materials
Three outlet in a row above 6 mts upto 10 mts from the tapping point to outlet via switches
| Point | 1225.37 | 1225.37 | 287.0 | False | None | None | False | None | False | 351681.19 | 0 | 3262866 | 113029 | None | Chapter-3 P.No 8 It.No 3.0 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.
1 - 2 Way
| Each | 112.75 | 112.75 | 80.0 | False | None | None | False | None | False | 9020.0 | 0 | 3262867 | 113029 | None | Chapter-3 P.No 8 It.No 3.3.2 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.
3Way
| Each | 151.16 | 151.16 | 75.0 | False | None | None | False | None | False | 11337.0 | 0 | 3262868 | 113029 | None | Chapter-3 P.No 8 It.No 3.3.3 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.
4 - 5Way
| Each | 184.61 | 184.61 | 142.0 | False | None | None | False | None | False | 26214.62 | 0 | 3262869 | 113029 | None | Chapter-3 P.No 8 It.No 3.3.4 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.
6 Way
| Each | 241.61 | 241.61 | 25.0 | False | None | None | False | None | False | 6040.25 | 0 | 3262870 | 113029 | None | Chapter-3 P.No 8 It.No 3.3.5 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.
8 Way
| Each | 241.61 | 241.61 | 10.0 | False | None | None | False | None | False | 2416.1 | 0 | 3262871 | 113029 | None | Chapter-3 P.No 8 It.No 3.4.1 | Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall
1 - 2 Way
| Each | 170.98 | 170.98 | 686.0 | False | None | None | False | None | False | 117292.28 | 0 | 3262872 | 113029 | None | Chapter-3 P.No 8 It.No 3.4.2 | Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall
3Way
| Each | 197.0 | 197.0 | 610.0 | False | None | None | False | None | False | 120170.0 | 0 | 3262873 | 113029 | None | Chapter-3 P.No 8 It.No 3.4.3 | Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall
4 - 5Way
| Each | 219.3 | 219.3 | 780.0 | False | None | None | False | None | False | 171054.0 | 0 | 3262874 | 113029 | None | Chapter-3 P.No 8 It.No 3.4.4 | Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall
6 Way
| Each | 272.58 | 272.58 | 190.0 | False | None | None | False | None | False | 51790.2 | 0 | 3262875 | 113029 | None | Chapter-3 P.No 8 It.No 3.4.5 | Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall
8 Way
| Each | 323.38 | 323.38 | 75.0 | False | None | None | False | None | False | 24253.5 | 0 | 3262876 | 113029 | None | Chapter-3 P.No 8 It.No 3.4.6 | Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall
10 / 12 Way
| Each | 395.24 | 395.24 | 80.0 | False | None | None | False | None | False | 31619.2 | 0 | 3262877 | 113029 | None | Chapter-3 P.No 8 It.No 3.4.7 | Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall
16 Way
| Each | 449.76 | 449.76 | 62.0 | False | None | None | False | None | False | 27885.12 | 0 | 3262878 | 113029 | None | Chapter-3 P.No 8 It.No 3.4.8 | Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall
18 Way
| Each | 501.8 | 501.8 | 15.0 | False | None | None | False | None | False | 7527.0 | 0 | 3262879 | 113029 | None | Chapter-3 P.No 8 It.No 3.5.1 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box
1 to 2 Module
| Each | 169.74 | 169.74 | 686.0 | False | None | None | False | None | False | 116441.64 | 0 | 3262880 | 113029 | None | Chapter-3 P.No 8 It.No 3.5.2 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box
3 Module
| Each | 199.48 | 199.48 | 610.0 | False | None | None | False | None | False | 121682.8 | 0 | 3262881 | 113029 | None | Chapter-3 P.No 8 It.No 3.5.3 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box
4 Module
| Each | 216.83 | 216.83 | 780.0 | False | None | None | False | None | False | 169127.4 | 0 | 3262882 | 113029 | None | Chapter-3 P.No 8 It.No 3.5.4 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box
6 Module
| Each | 289.93 | 289.93 | 190.0 | False | None | None | False | None | False | 55086.7 | 0 | 3262883 | 113029 | None | Chapter-3 P.No 8 It.No 3.5.5 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box
8 Module
| Each | 351.88 | 351.88 | 75.0 | False | None | None | False | None | False | 26391.0 | 0 | 3262884 | 113029 | None | Chapter-3 P.No 8 It.No 3.5.6 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box
10/12Module
| Each | 426.22 | 426.22 | 80.0 | False | None | None | False | None | False | 34097.6 | 0 | 3262885 | 113029 | None | Chapter-3 P.No 8 It.No 3.5.7 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box
16Module
| Each | 491.88 | 491.88 | 62.0 | False | None | None | False | None | False | 30496.56 | 0 | 3262886 | 113029 | None | Chapter-3 P.No 8 It.No 3.5.8 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box
18Module
| Each | 566.22 | 566.22 | 15.0 | False | None | None | False | None | False | 8493.3 | 0 | 3262887 | 113029 | None | Chapter-3 P.No 9 It.No 3.6.1 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293
6 amps one way switch
| Each | 126.38 | 126.38 | 3200.0 | False | None | None | False | None | False | 404416.0 | 0 | 3262888 | 113029 | None | Chapter-3 P.No 9 It.No 3.6.2 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293
6 amps two way switch
| Each | 205.67 | 205.67 | 86.0 | False | None | None | False | None | False | 17687.62 | 0 | 3262889 | 113029 | None | Chapter-3 P.No 9 It.No 3.6.3 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293
6 Amps 3 way sockets
| Each | 211.87 | 211.87 | 990.0 | False | None | None | False | None | False | 209751.3 | 0 | 3262890 | 113029 | None | Chapter-3 P.No 9 It.No 3.6.4 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293
stepped fan Regulator's
| Each | 442.32 | 442.32 | 460.0 | False | None | None | False | None | False | 203467.2 | 0 | 3262891 | 113029 | None | Chapter-3 P.No 9 It.No 3.6.10 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293
6/16 Amps universal sockets
| Each | 292.4 | 292.4 | 890.0 | False | None | None | False | None | False | 260236.0 | 0 | 3262892 | 113029 | None | Chapter-3 P.No 9 It.No 3.6.7 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293
16A one way switch
| Each | 223.02 | 223.02 | 880.0 | False | None | None | False | None | False | 196257.6 | 0 | 3262893 | 113029 | None | Chapter-3 P.No 9 It.No 3.6.9 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293
32A DP switch
| Each | 403.91 | 403.91 | 120.0 | False | None | None | False | None | False | 48469.2 | 0 | 3262894 | 113029 | None | Chapter-3 P.No 9 It.No 3.6.8 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293
6A Bell push
| Each | 219.3 | 219.3 | 20.0 | False | None | None | False | None | False | 4386.0 | 0 | 3262895 | 113029 | None | Chapter-12 P.No 48 It.No 12.2.1 | Supplying and fixing one of 230 V Ding dong bell and a flush
type bell push with gang box fixed on necessary wooden or rawl
plugs using NF screws with Remote.
Ding Donng bell
| Each | 304.79 | 304.79 | 20.0 | False | None | None | False | None | False | 6095.8 | 0 | 3262896 | 113029 | None | Chapter-13 P.No 56 It.No 13.12 | Supplying and fixing one of 230 V Ding dong bell and a flush
type bell push with gang box fixed on necessary wooden or rawl
plugs using NF screws with Remote.Extra length of GI pipe of class B 19mm dia for down rod.
| Each | 244.08 | 244.08 | 460.0 | False | None | None | False | None | False | 112276.8 | 0 | 3262897 | 113029 | None | Chapter-1 P.No 4 It.No 1.13 | Supplying and fixing one of 230 V Ding dong bell and a flush
type bell push with gang box fixed on necessary wooden or rawl
plugs using NF screws with Remote.
Supply and fixing one metal Fan box with round hook
| Each | 144.96 | 144.96 | 460.0 | False | None | None | False | None | False | 66681.6 | 0 | 3262898 | 113029 | None | Chapter-1 P.No 2 It.No 1.2.2 | Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc.and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary
25 mm dia 2mm thick
| Rmtr | 100.36 | 100.36 | 1200.0 | False | None | None | False | None | False | 120432.0 | 0 | 3262899 | 113029 | None | Chapter-1 P.No 2 It.No 1.2.3 | Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc.and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary
32 mm dia 2.5mm thick
| Rmtr | 131.33 | 131.33 | 250.0 | False | None | None | False | None | False | 32832.5 | 0 | 3262900 | 113029 | None | Chapter-1 P.No 2 It.No 1.2.1 | Supplying 2 mm thick heavy gauge PVC conduit pipe with bends metal junction boxes adhesives paste etc by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wll surface and run with 18 SWG Gi fish wire run through out the conduit wherever necessary.
19/20 mm dia 2mm thick
| Rmtr | 81.77 | 81.77 | 16000.0 | False | None | None | False | None | False | 1308320.0 | 0 | 3262901 | 113029 | None | Chapter-1 P.No 2 It.no 1.2 | Supplying 2 mm thick heavy gauge PVC conduit pipe with bends metal junction boxes adhesives paste etc by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wll surface and run with 18 SWG Gi fish wire run through out the conduit wherever necessary.
25 mm dia 2mm thick
| Rmtr | 96.64 | 96.64 | 20650.0 | False | None | None | False | None | False | 1995616.0 | 0 | 3262902 | 113029 | None | Chapter-1 P.No 2 It.No 1.3.3 | Supplying 2 mm thick heavy gauge PVC conduit pipe with bends metal junction boxes adhesives paste etc by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wll surface and run with 18 SWG Gi fish wire run through out the conduit wherever necessary.
32 mm dia 2.5mm thick
| Rmtr | 127.62 | 127.62 | 6500.0 | False | None | None | False | None | False | 829530.0 | 0 | 3262903 | 113029 | None | Chapter-1 P.No 2 It.No 1.3.1 | Supplying 2 mm thick heavy gauge PVC conduit pipe with bends metal junction boxes adhesives paste etc by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wll surface and run with 18 SWG Gi fish wire run through out the conduit wherever necessary.
19/20mm deep junction box
| Rmtr | 81.77 | 81.77 | 2695.0 | False | None | None | False | None | False | 220370.15 | 0 | 3262904 | 113029 | None | Chapter-1 P.No 3 It.No 1.3.2 | Supplying 2 mm thick heavy gauge PVC conduit pipe with bends metal junction boxes adhesives paste etc by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wll surface and run with 18 SWG Gi fish wire run through out the conduit wherever necessary.
25mm deep junction box
| Rmtr | 97.88 | 97.88 | 3010.0 | False | None | None | False | None | False | 294618.8 | 0 | 3262905 | 113029 | None | Chapter-1 P.No 3 It.No 1.3.3 | Supplying 2 mm thick heavy gauge PVC conduit pipe with bends metal junction boxes adhesives paste etc by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wll surface and run with 18 SWG Gi fish wire run through out the conduit wherever necessary.
32mm deep junction box
| Rmtr | 122.66 | 122.66 | 450.0 | False | None | None | False | None | False | 55197.0 | 0 | 3262906 | 113029 | None | Chapter-2 P.No 5 It.No 2.3.2 | FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments.
1.5 Sq.mm
| Rmtr | 32.21 | 32.21 | 22750.0 | False | None | None | False | None | False | 732777.5 | 0 | 3262907 | 113029 | None | Chapter-2 P.No 5 It.No 2.3.3 | FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments.
2.5 sq.mm
| Rmtr | 52.04 | 52.04 | 41650.0 | False | None | None | False | None | False | 2167466.0 | 0 | 3262908 | 113029 | None | Chapter-2 P.No 5 It.No 2.3.4 | FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments.
4 sq.mm
| Rmtr | 78.06 | 78.06 | 23450.0 | False | None | None | False | None | False | 1830507.0 | 0 | 3262909 | 113029 | None | Chapter-2 P.No 5 It.No 2.3.5 | FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments.
6sq.mm
| Rmtr | 113.99 | 113.99 | 5670.0 | False | None | None | False | None | False | 646323.3 | 0 | 3262910 | 113029 | None | Chapter-2 P.No 5 It.No 2.3.6 | FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments.
10sq.mm
| Rmtr | 206.91 | 206.91 | 4060.0 | False | None | None | False | None | False | 840054.6 | 0 | 3262911 | 113029 | None | Chapter-2 P.No 5 It.No 2.3.7 | FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments.
16sq.mm
| Rmtr | 394.0 | 394.0 | 3465.0 | False | None | None | False | None | False | 1365210.0 | 0 | 3262912 | 113029 | None | Least Quotation Rate | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes.
1.5 sq.mm
| Each | 3.54 | 3.54 | 3240.0 | False | None | None | False | None | False | 11469.6 | 0 | 3262913 | 113029 | None | Least Quotation Rate | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes.
2.5 sq.mm
| Each | 4.72 | 4.72 | 5600.0 | False | None | None | False | None | False | 26432.0 | 0 | 3262914 | 113029 | None | Least Quotation Rate | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes.
4 sq.mm
| Each | 8.26 | 8.26 | 2100.0 | False | None | None | False | None | False | 17346.0 | 0 | 3262915 | 113029 | None | Least Quotation Rate | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes.
6 sq.mm
| Each | 8.26 | 8.26 | 600.0 | False | None | None | False | None | False | 4956.0 | 0 | 3262916 | 113029 | None | Least Quotation Rate | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes.
10 sqmm
| Each | 9.44 | 9.44 | 560.0 | False | None | None | False | None | False | 5286.4 | 0 | 3262917 | 113029 | None | Least Quotation Rate | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes.
10 sqmm
| Each | 14.16 | 14.16 | 300.0 | False | None | None | False | None | False | 4248.0 | 0 | 3262918 | 113029 | None | Chapter-5 P.No 18 It.No5.19.8 | Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure.
8 Way SP & N
| Each | 2297.11 | 2297.11 | 12.0 | False | None | None | False | None | False | 27565.32 | 0 | 3262919 | 113029 | None | Chapter-5 P.No 18 It.No 5.19.9 | Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure.
12 Way SP & N
| Each | 2885.63 | 2885.63 | 14.0 | False | None | None | False | None | False | 40398.82 | 0 | 3262920 | 113029 | None | Chapter-5 P.No 18 It.No 5.19.11 | Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure.
4 Way TP & N
| Each | 5003.08 | 5003.08 | 19.0 | False | None | None | False | None | False | 95058.52 | 0 | 3262921 | 113029 | None | Chapter-5 P.No 18 It.No 5.19.12 | Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure.
6 Way TP & N
| Each | 6120.66 | 6120.66 | 19.0 | False | None | None | False | None | False | 116292.54 | 0 | 3262922 | 113029 | None | Chapter-5 P.No 18 It.No 5.19.13 | Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure.
8 Way TP & N
| Each | 7546.75 | 7546.75 | 11.0 | False | None | None | False | None | False | 83014.25 | 0 | 3262923 | 113029 | None | Chapter-5 P.No 18 It.No 5.19.14 | Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure.
12 Way TP & N
| Each | 10822.67 | 10822.67 | 10.0 | False | None | None | False | None | False | 108226.7 | 0 | 3262924 | 113029 | None | Chapter-5 P.No 17 It.No 5.17.3 | Supplying and fixing regular MCCB distribution Panel
confirming to IS/IEC 61439 - 3 and IK09 tested as per IS/IEC
62262 with minimum IP43 protection provided with
Polyurethane (PUR) gasket, with suitable earthing system, on
wall/wood board/flush mounting using required cl A , bolts,
nuts, etc., with provision for fixing of suitable type capacity
MCCB's as an incomer for 3 phase Double door with necessary
bus bar completely wired to use on 440V 3phase 4 wire powder
coated painting etc., complete with a provision for fixing of
single/three phase suitable capacity MCB's as outgoings
confirming to IS/IEC 60898 - 2.
12 Way
| Each | 19240.43 | 19240.43 | 3.0 | False | None | None | False | None | False | 57721.29 | 0 | 3262925 | 113029 | None | Chapter-5 P.No 17 It.No 5.15.9 | Supplying and fixing regular MCCB distribution Panel
confirming to IS/IEC 61439 - 3 and IK09 tested as per IS/IEC
62262 with minimum IP43 protection provided with
Polyurethane (PUR) gasket, with suitable earthing system, on
wall/wood board/flush mounting using required cl A , bolts,
nuts, etc., with provision for fixing of suitable type capacity
MCCB's as an incomer for 3 phase Double door with necessary
bus bar completely wired to use on 440V 3phase 4 wire powder
coated painting etc., complete with a provision for fixing of
single/three phase suitable capacity MCB's as outgoings
confirming to IS/IEC 60898 - 2.
100 A 25 kA
| Each | 10515.39 | 10515.39 | 5.0 | False | None | None | False | None | False | 52576.95 | 0 | 3262926 | 113029 | None | Chapter-5 P.No 17 It.No 5.18.1 | Supplying & fixing miniature circuit breakers on existing
MCB distribution boards using necessary fixing materials
and 'C' Type curve, indicator ON/OFF, energy cross-3 with
Short circuit breaking capacity of 10K and complete wiring as
required confirming to IEC 60898.
6-32 A SP
| Each | 514.19 | 514.19 | 1056.0 | False | None | None | False | None | False | 542984.64 | 0 | 3262927 | 113029 | None | Chapter-5 P.No 17 It.No 5.18.5 | Supplying & fixing miniature circuit breakers on existing
MCB distribution boards using necessary fixing materials
and 'C' Type curve, indicator ON/OFF, energy cross-3 with
Short circuit breaking capacity of 10K and complete wiring as
required confirming to IEC 60898.
40 A DP
| Each | 1313.34 | 1313.34 | 150.0 | False | None | None | False | None | False | 197001.0 | 0 | 3262928 | 113029 | None | Chapter-5 P.No 18 It.No 5.18.9 | Supplying & fixing miniature circuit breakers on existing
MCB distribution boards using necessary fixing materials
and 'C' Type curve, indicator ON/OFF, energy cross-3 with
Short circuit breaking capacity of 10K and complete wiring as
required confirming to IEC 60898.
50-63 A TPN
| Each | 3826.03 | 3826.03 | 78.0 | False | None | None | False | None | False | 298430.34 | 0 | 3262929 | 113029 | None | Chapter-5 P.No 18 It.No 5.20.4 | Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V up to 300mA sensitivity on existing wood/ panel board.
32-40Amps 2 pole
| Each | 5648.6 | 5648.6 | 46.0 | False | None | None | False | None | False | 259835.6 | 0 | 3262930 | 113029 | None | Chapter-5 P.No 18 It.No 5.20.10 | Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V up to 300mA sensitivity on existing wood/ panel board.
63Amps 4 pole
| Each | 6870.26 | 6870.26 | 12.0 | False | None | None | False | None | False | 82443.12 | 0 | 3262931 | 113029 | None | Chapter-5 P.No 14 It.No 5.5.2 | Supplying of TPST with rewirable porcelain channels in SM
enclosure. Made out of 14 SWG powder coated paint of
approved colour.
63A
| Each | 5195.13 | 5195.13 | 12.0 | False | None | None | False | None | False | 62341.56 | 0 | 3262932 | 113029 | None | Chapter-5 P.No 14 It.No 5.5.3 | Supplying of TPST with rewirable porcelain channels in SM enclosure. Made out of 14 SWG powder coated paint of approved colour.
100A
| Each | 9380.47 | 9380.47 | 10.0 | False | None | None | False | None | False | 93804.7 | 0 | 3262933 | 113029 | None | Least Quotation Rate | Supply, Installation, testing & Commissioning of 63A, three phase 5pin Plug & socket outlet controlled by 63A 4pole MCB
| Each | 10207.0 | 10207.0 | 12.0 | False | None | None | False | None | False | 122484.0 | 0 | 3262934 | 113029 | None | Least Quotation Rate | Supply, Installation, testing & Commissioning of 32A, single phase 3pin plug & socket outlet controlled by 32A 2POLE MCB
| Each | 4484.0 | 4484.0 | 14.0 | False | None | None | False | None | False | 62776.0 | 0 | 3262935 | 113029 | None | Least Quotation Rate | Supply & installation of 300 mm wide & 40mm height, 1.6 mm thick ladder type cable trays fixed with MS supports,anchor bolt etc.,complete as required at site.
| Rmtr | 548.7 | 548.7 | 320.0 | False | None | None | False | None | False | 175584.0 | 0 | 3262936 | 113029 | None | Least Quotation Rate | Supply & installation of 300 mm wide & 40mm height, 1.6 mm thick Perfforated cable trays fixed with MS supports,anchor bolt etc.,complete as required at site.
| Rmtr | 1097.4 | 1097.4 | 285.0 | False | None | None | False | None | False | 312759.0 | 0 | 3262937 | 113029 | None | Least Quotation Rate | Supply & installation of 150 mm wide & 40mm height, 1.6 mm thick Perfforated cable trays fixed with MS supports,anchor bolt etc.,complete as required at site.
| Rmtr | 684.4 | 684.4 | 195.0 | False | None | None | False | None | False | 133458.0 | 0 | 3262938 | 113029 | None | Least Quotation Rate | Supply & laying of Raceways 200mm wide x 40mm Deep MS cold galvanised 16 guage made of CRCA sheet with removable type cover plate maximum length of each section shall not be more than 2.5 Mtrs. Length. etc., as required.
| Rmtr | 1020.7 | 1020.7 | 120.0 | False | None | None | False | None | False | 122484.0 | 0 | 3262939 | 113029 | None | Least Quotation Rate | Supply & laying of Raceways 100mm wide x 40mm Deep MS cold galvanised 16 guage made of CRCA sheet with removable type cover plate maximum length of each section shall not be more than 2.5 Mtrs. Length. etc., as required.
| Rmtr | 719.8 | 719.8 | 65.0 | False | None | None | False | None | False | 46787.0 | 0 | 3262940 | 113029 | None | Chapter-15 - LIGHTING CONTROLS P.No 45 It.No 15.2 | Supplying,Installation,testing and commissioning of passive infrared (PIR) technology based accupancy sensor with day light dimming (Lighting levell shall be regulated as per availability of natural day light in an area along with accuoancy detection). Having high preformance,regulating programmable type,suitable for connected load upto 10 Amp,for mounting height upto 2.8 mtr. and for 5 m diameter coverage area along with necessary fixing arrangements i/c programming at site etc, complete as required.(DSR - 2022)
| Each | 10821.78 | 10821.78 | 18.0 | False | None | None | False | None | False | 194792.04 | 0 | 3262941 | 113029 | None | Chapter-15 - LIGHTING CONTROLS P.No 45 It.No 15.3 | Supplying,Installation,testing and commissioning of microwave technology based accupancy sensor having high preformance,non regulating programmable type,suitable for connected load upto 10 Amp,for mounting height upto 2.6 mtr. and for 5 m X 20m coverage area along with necessary fixing arrangements i/c programming at site etc, complete as required.(DSR - 2022)
| Each | 14033.74 | 14033.74 | 14.0 | False | None | None | False | None | False | 196472.36 | 0 | 3262942 | 113029 | None | Chapter-11 P.No 43 It.No 11.3.1 | Supplying of .feet -PVC Batten with integrated LED tube .W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V@ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.
LED light fitting 1 x 2' - 9/10 W | Each | 682.69 | 682.69 | 120.0 | False | None | None | False | None | False | 81922.8 | 0 | 3262943 | 113029 | None | Chapter-11 P.No 43 It.No 11.3.2 | Supplying of .feet -PVC Batten with integrated LED tube .
W with high quality diffuser with Life of 25000 burning
hours & 70% lumen maintenance with CRI 80. Power
Input: 220-240V@ 50/60Hz & Power factor 0.9 along with CE
approved. 2 years Warranty against any manufacturing defect
working under standard electrical condition.
LED light fitting 1 x 4' - 20/22 W
| Each | 854.91 | 854.91 | 620.0 | False | None | None | False | None | False | 530044.2 | 0 | 3262944 | 113029 | None | Chapter-11 P.No 43 It.No 11.3.3 | Supplying of .feet -PVC Batten with integrated LED tube .
W with high quality diffuser with Life of 25000 burning
hours & 70% lumen maintenance with CRI 80. Power
Input: 220-240V@ 50/60Hz & Power factor 0.9 along with CE
approved. 2 years Warranty against any manufacturing defect
working under standard electrical condition.
LED light fitting 1 x 4' - 36/40 W
| Each | 1572.29 | 1572.29 | 45.0 | False | None | None | False | None | False | 70753.05 | 0 | 3262945 | 113029 | None | Chapter-11 P.No 44 It.No 11.5.2 | Supply of round/square recess/surface mounted rolling
type LED Down light with . W GU 10 LED Lamp Rib
Fabricated from diecast aluminium with white powder
coated prewired to mains connector & has swivelling unit of
aluminium die cast eye ball & LED Lamp position retained by
circular wire spring, with Life of 25000 burning hours & 70%
lumen maintenance with CRI 80. Power Input: 220-240V
@50/60Hz & Power factor 0.9 along with CE approved. 2years
Warranty against any manufacturing defect working under
standard electrical condition | Each | 1096.52 | 1096.52 | 190.0 | False | None | None | False | None | False | 208338.8 | 0 | 3262946 | 113029 | None | Chapter-11 P.No 44 It.No 11.5.3 | Supply of round/square recess/surface mounted rolling
type LED Down light with . W GU 10 LED Lamp Rib
Fabricated from diecast aluminium with white powder
coated prewired to mains connector & has swivelling unit of
aluminium die cast eye ball & LED Lamp position retained by
circular wire spring, with Life of 25000 burning hours & 70%
lumen maintenance with CRI 80. Power Input: 220-240V
@50/60Hz & Power factor 0.9 along with CE approved. 2years
Warranty against any manufacturing defect working underLED square or round down light 15-18W
standard electrical condition
| Each | 1640.44 | 1640.44 | 210.0 | False | None | None | False | None | False | 344492.4 | 0 | 3262947 | 113029 | None | Chapter-11 P.No 45 It.No 11.6.3 | Supplying of recess mounting non integral type . LED w
luminaire comprising of pressure decast/extruded aluminium
housing, with spring loaded false ceiling clA, Power LEDs with
CCT 6500 degree K, CRI 70%. efficacy 100 lumen per W,
120degree beam spread, life 25000 burning hours and
Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The
lamp compartment is enclosed with anti glare opal diffuser
which enhances the lighting level LEDs are driven by HF
electronic driver integrated in a separate control gear
assembly., with PF 0.95, power loss should 5% of lamp
Wage., short circuit & open circuit protection to be integrated
in the circuit, THD less than 20%, Life as per LM 79. The
operating input voltage should be between 130 to 275 V. BIS
Approved and Tested by NABL/CPRI accredited laboratory
with 2 years Warranty against any manufacturing defect
working under standard electrical condition.
LED modular down light 2'x2' - 36W | Each | 5641.17 | 5641.17 | 80.0 | False | None | None | False | None | False | 451293.6 | 0 | 3262948 | 113029 | None | Least Quotation Rate | Supply and fixing of 18W LED Bulk Head light Fixture
| Each | 2183.0 | 2183.0 | 40.0 | False | None | None | False | None | False | 87320.0 | 0 | 3262949 | 113029 | None | Chapter-6 P.No 22 It.No 6.1 | Supplying exhaust fan of 1440 RPM of 300 mm (12"") size with
bracket blades complete for light duty suitable to operate on
230V 50Hz, AC Supply. | Each | 1910.54 | 1910.54 | 80.0 | False | None | None | False | None | False | 152843.2 | 0 | 3262950 | 113029 | None | Chapter-6 P.No 30 It.No 6.4.1 | Supplying of Ceiling Fan with Capacitor rating As per
guideline of BEE 5 star rating and IS:374/79 and also
comply with IS: 1709/1984 with latest amendment, Rated
voltage 220 V/50 Hz, Rated power input 48 W +/- 10 %,
Rated current As per IS:374/79, Rated power factor 0.9
lagging(min), Rated speed 350 +/- 10% RPM, Rated air
delivery 210 +/- 10% Cubic Meter Minimum, Rated service
value 4.2 CMM / W, Three Blades of blade leaf 1.05 mm thick
Aluminium Alloy sheet, Class B motor insulation, Bearing Two
ball bearings, Top 6202, Bottom 6201, as per IS specification,
Motor winding. Temp rise Shall not exceed 75 deg C over and
ambient of 40 0C by resistance method at 245 V, Insulation
resistance Shall not be less than Two Mega Ohms (2M Ohms),
Leakage current Should not exceed 210 Micro Amp, Power
input, W& current, Air Delivery & Fan Speed as per
IS:374/1979 with latest amendment, 2 year manufacturer
Warranty.
48" Sweep 5 Star (1200 mm) | Each | 3316.8 | 3316.8 | 450.0 | False | None | None | False | None | False | 1492560.0 | 0 | 3262951 | 113029 | None | Chapter-6 P.No 30 It.No 6.4.2 | Supplying of Ceiling Fan with Capacitor rating As per
guideline of BEE 5 star rating and IS:374/79 and also
comply with IS: 1709/1984 with latest amendment, Rated
voltage 220 V/50 Hz, Rated power input 48 W +/- 10 %,
Rated current As per IS:374/79, Rated power factor 0.9
lagging(min), Rated speed 350 +/- 10% RPM, Rated air
delivery 210 +/- 10% Cubic Meter Minimum, Rated service
value 4.2 CMM / W, Three Blades of blade leaf 1.05 mm thick
Aluminium Alloy sheet, Class B motor insulation, Bearing Two
ball bearings, Top 6202, Bottom 6201, as per IS specification,
Motor winding. Temp rise Shall not exceed 75 deg C over and
ambient of 40 0C by resistance method at 245 V, Insulation
resistance Shall not be less than Two Mega Ohms (2M Ohms),
Leakage current Should not exceed 210 Micro Amp, Power
input, W& current, Air Delivery & Fan Speed as per
IS:374/1979 with latest amendment, 2 year manufacturer
Warranty.
56" Sweep 5 Star (1400 mm)
| Each | 4651.21 | 4651.21 | 10.0 | False | None | None | False | None | False | 46512.1 | 0 | 3262952 | 113029 | None | Chapter-6 P.No 30 It.No 6.5.2 | Supplying wall mounting fan suitable to operate at singlephase
230v AC. supply.
400 mm Sweep
| Each | 3979.67 | 3979.67 | 10.0 | False | None | None | False | None | False | 39796.7 | 0 | 3262953 | 113029 | None | Chapter-13 P.No 56 It.No 13.7.1 | Fixing all types and all capacities of fluorescent /false ceiling /
spot light / CFL / LED fittings indoor on the wall/ ceiling /
rafters / girders using 23/0.0076"" twin twisted PVC insulated
wires, required Nos of round blocks and Clamps. - On wall/Rafter/Girders | Each | 151.16 | 151.16 | 1518.0 | False | None | None | False | None | False | 229460.88 | 0 | 3262954 | 113029 | None | Chapter-13 P.No 57 It.No 13.11 | Fixing a ceiling / Wall mounting fan of all capacities and all
types to the existing 'S'' hook with fan regulator to the existing
board together with supplying and fixing 5 A. ceiling rose,
necessary length of 23 / 0.0076 inch PVC insulated twin
twisted copper wire and wiring. | Each | 390.29 | 390.29 | 470.0 | False | None | None | False | None | False | 183436.3 | 0 | 3262955 | 113029 | None | Chapter-13 P.No 57 It.No 13.14 | Fixing one exhaust fan in the nitch already left in the wall with
bolts and nuts and 5 A. ceiling rose with sufficient length of 23/0.0076 inch PVC insulated twin core wire.
| Each | 609.59 | 609.59 | 80.0 | False | None | None | False | None | False | 48767.2 | 0 | 3262956 | 113029 | None | Chapter-2 P.No 6 It.No 2.5.8 | Supplying and drawing Flexible Multicore Cable manufactured
with electrolytic grade flexible copper with low conductor
confirming to IS 8130-1984 and (Virgin) PVC insulation
sheathed suitable for working voltage upto 1100V as per IS694:2010
3C x 2.5 sqmm
| Rmtr | 140.01 | 140.01 | 600.0 | False | None | None | False | None | False | 84006.0 | 0 | 3262957 | 113029 | None | Chapter-2 P.No 6 It.No 2.5.15 | Supplying and drawing Flexible Multicore Cable manufactured
with electrolytic grade flexible copper with low conductor
confirming to IS 8130-1984 and (Virgin) PVC insulation
sheathed suitable for working voltage upto 1100V as per IS694:2010
3C x 4 sqmm
| Rmtr | 213.11 | 213.11 | 1100.0 | False | None | None | False | None | False | 234421.0 | 0 | 3262958 | 113029 | None | Chapter-11 P.No 46 It.No 11.9.2 | Supply of LED floodlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/clear glass material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mauling with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100 V to 270V 50/60Hz application. Compliance to IS 10322/ IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with 100W System Power consumption. LED Efficiency 1301m/w, nominal CRI 75. Luminaire manufacturer should have in- house facility accredited by NABL / CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark / name shall be Engraved / Embossing on the die cast housing / Body part Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source | Each | 11753.15 | 11753.15 | 12.0 | False | None | None | False | None | False | 141037.8 | 0 | 3262959 | 113029 | None | Chapter-4 P.No 12 It.No 4.4.5 | Fabricating, supplying and erection of . ms long hot
dip Galvanized Conical hot dip Pole with BSEN 10025 grade
S355JO steel plate for shaft, IS 2062 for base plate with door
opening arrangements, including suitable boards, Bakelite
sheet and MCBs as per IS specifications suitable to withstand
the wind speed of 47 m/s for . m Pole in single section and
single joint welded as per IS 9595/IS10178AWS having
dimensions bottom . mm , top . mm with 3 mm thick,
suitable base plate and 4Nos of.long J bolts along with
template and the Pole shall be hot dip galvanized in single
dipping with not less than 65micron as per ASTM-A123 and 153
etc.,(excluding foundation) as per drawing appended.
7 Meters- Top 75mm and botton 145mm dia | Each | 18585.0 | 18585.0 | 12.0 | False | None | None | False | None | False | 223020.0 | 0 | 3262960 | 113029 | None | Chapter-4 P.No 13 It.No 4.7.1 | Supplying, and fixing of hot dip Galvanized M.S.Bracket suitable for out door liminaries and mounted on Octagonal pole using necessary bolts, nuts etc., complete.
Single Arm Bracket with 1000mm Standard 40/50MM dia
| Each | 2106.3 | 2106.3 | 12.0 | False | None | None | False | None | False | 25275.6 | 0 | 3262961 | 113029 | None | Chapter-11 P.No 46 It.No 11.8 | LED STREET LIGHT Supply of LED street light with pressure die cast aluminium housing body with optimal heat sink for better thermal dissipation, Diffuser with injection moulded & is made of polycorbonate material with high transmission index, delivering superior light output . Rated life Burning Hrs. 50000 hr @ Lumen maintanance of 70%. CCT 5500 K, IP 66 optical and electrical compartment & impact resistance of complete luminare- IK08. Power Factor 0.9 with mains current should not be greater than 0.1A to 0.7 A& Surge Protection - Min 4 KV alongwith over voltage / overload, short circuit/ miss wiring protection. Compatable for pole mounting with outer dia of 40 mm to 50mm .Universal voltage driver to operates wide voltage from 100 V to 270 Volts , 50 / 60 Hz application. Over load and short circuit protection ensures reliable operation in spite of problem in output side. Complaince to IS 10322/IEC 60598, LM 79 & LM 80 Adherance with ROHS .UL approved MCPCB .Top access street light with single screws to ensure ease of maintenance at the sight site location with minimized tools. LED Light fixture with. W System Power consumption. LED Efficiency 130 / m/w at Fixture Efficiency 80 /m/w with nominal CRI 75 Luminarie manufacture should have in-house facility accredited by NABL/ CPRI & any government certified agency & Design with supplier word mark/ name shall be Engraved/ Embossing on the die cast housing/ Body part. Warranty of 2 years against any manufacturing defects working under standard electrical conditions suitable for B1/ B2 Roads as per IS 1944 Part & Part II. LED Streetlight 70watts | Each | 7424.09 | 7424.09 | 12.0 | False | None | None | False | None | False | 89089.08 | 0 | 3262962 | 113029 | None | Chapter-13 P.No 56 It.No 13.5 | Fixing halogen/metal halide /SVL/IL/LED floodlight fitting over
existing pole / wall ceiling including clA, bolts, nuts and wiring
using suitable capacity wires.
| Each | 200.72 | 200.72 | 12.0 | False | None | None | False | None | False | 2408.64 | 0 | 3262963 | 113029 | None | Least Quotation Rate | Supply and laying double walled corrugated (DWC) HDPE pipe inculding all necessary connecting sockets / couplings / Tees / bends / End-caps of same materials in existing trench as per is 14930 part-11 suitable for drawing underground cable
63mm OD / 50MM ID
| Rmtr | 300.9 | 300.9 | 220.0 | False | None | None | False | None | False | 66198.0 | 0 | 3262964 | 113029 | None | It.No 6.6.1 | Digging of trench of 0.6m deep x 0.50 mtr wide refiling the trench to the required ground level and consolidating etc., complete.(As per Civil SR KSRB I-2, P-7)(70/6) ( SR 2019-2020 )
| Rmtr | 89.68 | 89.68 | 250.0 | False | None | None | False | None | False | 22420.0 | 0 | 3262965 | 113029 | None | It.No 6.7 | Providing and filling sand in excavated trench to cover already laid UG cable to a depth of 150mm all-round the cable. ( SR 2019-2020 )
| Rmtr | 118.0 | 118.0 | 250.0 | False | None | None | False | None | False | 29500.0 | 0 | 3262966 | 113029 | None | Least Quotation Rate | Supply, installation and commissioning of 1nos 30W LED luminaire with built in charge controller ,150WP-PV module polycrystalline, 100AH-LMLA C10 rated tubular type battery ,battery box of glvanised iron sheet, 9meter GI Pole with mounting frame and internal cable.
| Each | 61950.0 | 61950.0 | 4.0 | False | None | None | False | None | False | 247800.0 | 0 | 3262967 | 113029 | None | Chapter-11 P.No 35 It.No 11.7 | Supply of LED pole mounting type post top lantern with
pressure die cast aluminium housing body for optimal
thermal dissipation. Lamp compartment comprising of anti
glare clear diffuser with Injection moulded polycarbonate/
clear glass material, delivering superior light outputRated life
Burning Hrs 50000 hr@ Lumen Maintenance of 70%, CCT
5500K, IP 66 optical and electrical compartment & impact
resistance of complete luminaire IK08. Power Factor0.9 with
mains, Surge Protection- Min 5KV along with Over
voltage/Overload, short circuit/ miss-wiring protection.
Compatible for pole mounting with outer dia of 40mm to
50mm. Universal Voltage driver to operate wide voltage
range from 100V to 270V 50/60Hz application. Compliance to
IS 10322/1 EC 60598, LM 79 & LM 80 Adherence with
RoHS. UL approved MCPCB LED Efficiency1301m/w, nominal
CRI 75. Luminaire manufacturer should have in- house facility
accredited by NABL/CPRI & any Government certified agency
& Design & Development facility certified by ISO 9001:2008.
Housing with supplier word mark /name shall be Engraved /
Embossing on the die cast housing/ Body part Warranty of 2
Years against any manufacturing defect working under
standard electrical conditions as mentioned above should be
given by LED manufacturer & Cree/Nichia/ Lumileds/Osram
make LED Source.
11.7. 1 LED Post Top Lantern with 25/30 W
| Each | 9567.56 | 9567.56 | 14.0 | False | None | None | False | None | False | 133945.84 | 0 | 3262968 | 113029 | None | Chapter-11 P.No 38 It.No 11.12.1 | Supply of LED Bollard light fitting of .W with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/clear glass material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/Overload, short circuit/ miss-wiring protection. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB, with 2 years Warranty against any manufacturing defect working under standard electrical condition
8w 1 Mtr Height | Each | 5610.19 | 5610.19 | 14.0 | False | None | None | False | None | False | 78542.66 | 0 | 3262969 | 113029 | None | Chapter-5 P.No 20 It.No 5.42.1 | Fabricating supplying and mounting MS box made out
.SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with
7tanks treatment with powder coated paint and finally finished with approved colour etc., complete.
14 SWG
| Sq CM | 0.62 | 0.62 | 395000.0 | False | None | None | False | None | False | 244900.0 | 0 | 3262970 | 113029 | None | Chapter-5 P.No 20 It.No 5.40.5 | Supplying . A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete
1000 A double run of 4x60x10 mm Aluminium Strips
| Rmtr | 13108.62 | 13108.62 | 24.0 | False | None | None | False | None | False | 314606.88 | 0 | 3262971 | 113029 | None | Chapter-5 P.No 20 It.No 5.41.3 | Supplying and fixing angle iron frame work fabricated out of
M.S. angle iron. and M.S. Flat.with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint.
75 x 75 x 6 mm
| Rmtr | 687.65 | 687.65 | 32.0 | False | None | None | False | None | False | 22004.8 | 0 | 3262972 | 113029 | None | Chapter-5 P.No 16-17 It.No 5.15.20 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.700-800 A 50KA
| Each | 61826.1 | 61826.1 | 2.0 | False | None | None | False | None | False | 123652.2 | 0 | 3262973 | 113029 | None | Chapter-5 P.No 17 It.No 5.15.20 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.
700-800 A 50KA
| Each | 61826.1 | 61826.1 | 2.0 | False | None | None | False | None | False | 123652.2 | 0 | 3262974 | 113029 | None | Chapter-5 P.No 17 It.No 5.15.19 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.
500-630 A 50KA
| Each | 51912.86 | 51912.86 | 1.0 | False | None | None | False | None | False | 51912.86 | 0 | 3262975 | 113029 | None | Least Quotation Rate | Supplying & fixing of Model : - EASY GEN - 2300
| Each | 165200.0 | 165200.0 | 1.0 | False | None | None | False | None | False | 165200.0 | 0 | 3262976 | 113029 | None | Chapter-5 P.No 17 It.No 5.18.1 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.
6-32 A SP
| Each | 514.19 | 514.19 | 12.0 | False | None | None | False | None | False | 6170.28 | 0 | 3262977 | 113029 | None | Chapter-5 P.No 19 It.No 5.38 | Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz
12/24V D.C.
| Each | 638.09 | 638.09 | 6.0 | False | None | None | False | None | False | 3828.54 | 0 | 3262978 | 113029 | None | Chapter-5 P.No 18 It.No 5.22 | Supplying, fixing and wiring 0 to 600V 96x96mm AC
Voltmeter on existing panel/wood board.
| Each | 560.03 | 560.03 | 2.0 | False | None | None | False | None | False | 1120.06 | 0 | 3262979 | 113029 | None | Chapter-5 P.No 18 It.No 5.21 | Supplying, fixing and wiring earth leakage relay with core
balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board.
| Each | 11466.95 | 11466.95 | 2.0 | False | None | None | False | None | False | 22933.9 | 0 | 3262980 | 113029 | None | Chapter-5 P.No 19 It.No 5.34 | Supplying, fixing and wiring 50/5 to 400/5A 5VA burden
Current Transformer Class 0.5 accuracy with Tape Wound. | Each | 696.32 | 696.32 | 6.0 | False | None | None | False | None | False | 4177.92 | 0 | 3262981 | 113029 | None | Chapter-5 P.No 19 It.No 5.28 | Supplying, fixing and wiring rotary selector switch suitable for Voltmeter
| Each | 156.11 | 156.11 | 2.0 | False | None | None | False | None | False | 312.22 | 0 | 3262982 | 113029 | None | Chapter-5 P.No 19 It.No 5.29 | Supplying, fixing and wiring 3 Phase Digital Ammeter /Voltmeter
| Each | 1765.58 | 1765.58 | 2.0 | False | None | None | False | None | False | 3531.16 | 0 | 3262983 | 113029 | None | Chapter-2 P.No 5 It.No 2.3.2 | Wiring for lighting/power circuit using one of FRLS PVC
insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5 mm2
| Rmtr | 30.68 | 30.68 | 110.0 | False | None | None | False | None | False | 3374.8 | 0 | 3262984 | 113029 | None | Chapter-2 P.No 5 It.No 2.3.3 | Wiring for lighting/power circuit using one of FRLS PVC
insulated 1100V grade, multistrand copper wire with low
conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.
2.5 mm2
| Rmtr | 49.56 | 49.56 | 85.0 | False | None | None | False | None | False | 4212.6 | 0 | 3262985 | 113029 | None | Chapter-5 P.No 20 It.No 5.42.1 | Fabricating supplying and mounting MS crcabox made out
.SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with
7tanks treatment with powder coated paint and finally finished with approved colour etc., complete.14 SWG
| Sq CM | 0.62 | 0.62 | 670000.0 | False | None | None | False | None | False | 415400.0 | 0 | 3262986 | 113029 | None | Chapter-5 P.No 19 It.No 5.40 | Supplying . A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete 1000 A double run of 4x60x10 mm Aluminium Strips | Rmtr | 13108.62 | 13108.62 | 24.0 | False | None | None | False | None | False | 314606.88 | 0 | 3262987 | 113029 | None | Chapter-5 P.No 20 It.No 5.41.3 | Supplying and fixing angle iron frame work fabricated out of
M.S. angle iron. and M.S. Flat.with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint.
75 x 75 x 6 mm
| Rmtr | 687.65 | 687.65 | 18.0 | False | None | None | False | None | False | 12377.7 | 0 | 3262988 | 113029 | None | Chapter-5 16-17 It.No 5.15.13 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.
250 A 35 kA
| Each | 26503.45 | 26503.45 | 8.0 | False | None | None | False | None | False | 212027.6 | 0 | 3262989 | 113029 | None | Chapter-5 P.No 17 It.No 5.15.9 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.
100 A 25 kA
| Each | 10515.39 | 10515.39 | 12.0 | False | None | None | False | None | False | 126184.68 | 0 | 3262990 | 113029 | None | Chapter-5 P.No 21 It.No 5.18.1 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32 A SP
| Each | 514.19 | 514.19 | 12.0 | False | None | None | False | None | False | 6170.28 | 0 | 3262991 | 113029 | None | Chapter-5 P.No 18 It.No 5.18.9 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.
50-63 A TPN
| Each | 3826.03 | 3826.03 | 4.0 | False | None | None | False | None | False | 15304.12 | 0 | 3262992 | 113029 | None | Chapter-5 P.No19 It.No 5.38 | Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz
12/24V D.C. | Each | 638.09 | 638.09 | 12.0 | False | None | None | False | None | False | 7657.08 | 0 | 3262993 | 113029 | None | Chapter-5 P.No 18 It.No 5.22 | Supplying, fixing and wiring 0 to 600V 96x96mm AC
Voltmeter on existing panel/wood board. | Each | 560.03 | 560.03 | 4.0 | False | None | None | False | None | False | 2240.12 | 0 | 3262994 | 113029 | None | Chapter-5 P.No 18 It.No 5.21 | Supplying, fixing and wiring earth leakage relay with core
balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board.
| Each | 11466.95 | 11466.95 | 4.0 | False | None | None | False | None | False | 45867.8 | 0 | 3262995 | 113029 | None | Chapter-5 P.No 19 It.No 5.33 | Fixing a shunt capacitor of . kVAR capacity with necessary clA, bolts, and nuts on existing wooden or metal board including banking of more than one capacitor.50 kVAR
| Each | 11541.29 | 11541.29 | 4.0 | False | None | None | False | None | False | 46165.16 | 0 | 3262996 | 113029 | None | Chapter-5 P.No 19 It.No 5.28 | Supplying, fixing and wiring rotary selector switch suitable
for Voltmeter | Each | 198.24 | 198.24 | 2.0 | False | None | None | False | None | False | 396.48 | 0 | 3262997 | 113029 | None | Chapter-5 P.No 19 It.No 5.29 | Supplying, fixing and wiring 3 Phase Digital Ammeter /
Voltmeter | Each | 1765.58 | 1765.58 | 4.0 | False | None | None | False | None | False | 7062.32 | 0 | 3262998 | 113029 | None | Chapter-2 P.No 5 It.No 2.3.2 | Wiring for lighting/power circuit using one of FRLS PVC
insulated 1100V grade, multistrand copper wire with low
conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.
Automatic APFCR with controller along with colling Fans and Interlocking.
1.5 mm2
| Rmtr | 32.21 | 32.21 | 150.0 | False | None | None | False | None | False | 4831.5 | 0 | 3262999 | 113029 | None | Chapter-2 P.No 5 It.No 2.3.3 | Wiring for lighting/power circuit using one of FRLS PVC
insulated 1100V grade, multistrand copper wire with low
conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.
Automatic APFCR with controller along with colling Fans and Interlocking.
2.5 mm2
| Rmtr | 52.04 | 52.04 | 100.0 | False | None | None | False | None | False | 5204.0 | 0 | 3263000 | 113029 | None | Chapter-5 P.No 20 It.No 5.42.1 | Fabricating supplying and mounting MS box made out
.SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with
7tanks treatment with powder coated paint and finally finished with approved colour etc., complete.14 SWG
| Sq CM | 0.62 | 0.62 | 450000.0 | False | None | None | False | None | False | 279000.0 | 0 | 3263001 | 113029 | None | Chapter-5 P.No 20 It.No 5.39 | Supplying, fixing and wiring Automatic Power Factor controller circuit unit fully, static units controlled by 14 stage microprocessor operation, relays LED display, self programming function for power stages and operating logic checking facility for healthy and efficient of each individual capacitor bank, measurement of network harmonics with indication when limit values are exceeded, Comprehensive displays with large, three phase LED display, Long term memory for settings, protection for over voltage, power factor correction fault and no voltage, to connect/ disconnect banks, with automatic recognition or with standard programs | Each | 26811.96 | 26811.96 | 2.0 | False | None | None | False | None | False | 53623.92 | 0 | 3263002 | 113029 | None | Chapter-5 P.No 20 It.No 5.40.4 | Supplying . A rated 3Phase with Neutral bus bar arrangement using required capacity Electrolytic Al strips covered with Heat shrinkable PVC sleves mounted on Phenolic/FRP/DMC insulators which are mounted on powder coated 40x6mm MS flat frame work in existing Panel Board. The Bus bars shall have suitable holes for termination of Incoming & outgoing cables as per IS specification with necessary bolts, nuts & washers etc complete 600 A 4 x 75 x 10 mm Aluminium Strips
| Rmtr | 6969.38 | 6969.38 | 24.0 | False | None | None | False | None | False | 167265.12 | 0 | 3263003 | 113029 | None | Chapter-5 16-17 It.No 5.41.3 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.160 A 25 kA
75 x 75 x 6 mm
| Rmtr | 687.65 | 687.65 | 24.0 | False | None | None | False | None | False | 16503.6 | 0 | 3263004 | 113029 | None | Chapter-5 P.No 16-17 It.No 5.15.7 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mecha
400 A 36KA
| Each | 30511.61 | 30511.61 | 2.0 | False | None | None | False | None | False | 61023.22 | 0 | 3263005 | 113029 | None | Chapter-5 P.No 19 It.No 5.46.4 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.
100 A 25 kA
| Each | 9752.7 | 9752.7 | 4.0 | False | None | None | False | None | False | 39010.8 | 0 | 3263006 | 113029 | None | Chapter-5 P.No 16 It.No 5.46.4 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.
16 - 32 A TP
| Each | 1301.54 | 1301.54 | 4.0 | False | None | None | False | None | False | 5206.16 | 0 | 3263007 | 113029 | None | Chapter-5 P.No 13 It.No 5.17.9 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.
50-63 A TPN
| Each | 2830.82 | 2830.82 | 8.0 | False | None | None | False | None | False | 22646.56 | 0 | 3263008 | 113029 | None | Chapter-5 P.No 15 It.No 5.41.1 | Supplying and fixing angle iron frame work fabricated out of
M.S. angle iron. and M.S. Flat.with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint.40 x 40 x 6 mm
| Rmtr | 324.5 | 324.5 | 24.0 | False | None | None | False | None | False | 7788.0 | 0 | 3263009 | 113029 | None | Chapter-5 P.No 14 It.No 5.37 |
Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 V grade, for power factor improvement of rotating machineries like induction motor.
| Kvar | 594.72 | 594.72 | 197.0 | False | None | None | False | None | False | 117159.84 | 0 | 3263010 | 113029 | None | Chapter-5 P.No 14 It.No 5.4.2 | 6 to 10 kVAR
| Each | 265.15 | 265.15 | 2.0 | False | None | None | False | None | False | 530.3 | 0 | 3263011 | 113029 | None | Least Quotation Rate | ILPB Type push button with Lanmp - ON/OFF(L&T Make)
| Each | 413.0 | 413.0 | 16.0 | False | None | None | False | None | False | 6608.0 | 0 | 3263012 | 113029 | None | Chapter-5 P.No 15 It.No 5.13.1 | Supply and fixing of 4pole power contactor with NO/NC contacts on existing wood/panel board using necessary bolts, nuts, washers and wiring etc., complete with AC-3 Rating and as per IS-13947.
25A | Each | 1598.31 | 1598.31 | 1.0 | False | None | None | False | None | False | 1598.31 | 0 | 3263013 | 113029 | None | Chapter-5 P.No 22 It.No 5.52.3 | Supply and fixing of 3-pole Capacitor switching contactor with NO/NC contacts and inbuilt damping resistor to protect the contactor and capacitor from highest inrush current , fixed on existing wood/panel board using necessary bolts, nuts, washers and wiring etc., complete with AC 690V Rating operational voltage, 50HZ frequency and as per IS 60947-4-1.
30 KVAR
| Each | 6255.1 | 6255.1 | 8.0 | False | None | None | False | None | False | 50040.8 | 0 | 3263014 | 113029 | None | Chapter-5 P.No 22 It.No 5.52.5 | Supply and fixing of 3-pole Capacitor switching contactor with NO/NC contacts and inbuilt damping resistor to protect the contactor and capacitor from highest inrush current , fixed on existing wood/panel board using necessary bolts, nuts, washers and wiring etc., complete with AC 690V Rating operational voltage, 50HZ frequency and as per IS 60947-4-1.
50 KVAR
| Each | 18668.01 | 18668.01 | 4.0 | False | None | None | False | None | False | 74672.04 | 0 | 3263015 | 113029 | None | Chapter-5 P.No 17 It.No 5.18.1 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.
6-32 A SP
| Each | 514.19 | 514.19 | 6.0 | False | None | None | False | None | False | 3085.14 | 0 | 3263016 | 113029 | None | Chapter-5 P.No 19 It.No 5.38 | Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz
12/24V D.C | Each | 638.09 | 638.09 | 6.0 | False | None | None | False | None | False | 3828.54 | 0 | 3263017 | 113029 | None | Chapter-5 P.No 19 It.No 5.34 | Supplying, fixing and wiring 1000/5A to 1600/5A 15VA
Burden class 1 Current Transformer | Each | 696.32 | 696.32 | 6.0 | False | None | None | False | None | False | 4177.92 | 0 | 3263018 | 113029 | None | Chapter-2 P.No 5 It.No 2.3.2 | Wiring for lighting/power circuit using one of FRLS PVC
insulated 1100V grade, multistrand copper wire with low
conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.
Automatic APFCR with controller along with colling Fans and Interlocking.
1.5 mm2
| Rmtr | 32.21 | 32.21 | 185.0 | False | None | None | False | None | False | 5958.85 | 0 | 3263019 | 113029 | None | Chapter-2 P.No 5 It.No 2.3.3 | Wiring for lighting/power circuit using one of FRLS PVC
insulated 1100V grade, multistrand copper wire with low
conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.
Automatic APFCR with controller along with colling Fans and Interlocking.
2.5 mm2
| Rmtr | 52.04 | 52.04 | 80.0 | False | None | None | False | None | False | 4163.2 | 0 | 3263020 | 113029 | None | Chapter-2 P.No 5 It.No 2.3.4 | Wiring for lighting/power circuit using one of FRLS PVC
insulated 1100V grade, multistrand copper wire with low
conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.
Automatic APFCR with controller along with colling Fans and Interlocking.
4 mm2 Mtr 60
| Rmtr | 78.06 | 78.06 | 60.0 | False | None | None | False | None | False | 4683.6 | 0 | 3263021 | 113029 | None | Chapter-2 P.No 6 It.No 2.3.7 | Wiring for lighting/power circuit using one of FRLS PVC
insulated 1100V grade, multistrand copper wire with low
conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.
Automatic APFCR with controller along with colling Fans and Interlocking.
16 mm2
| Rmtr | 394.0 | 394.0 | 30.0 | False | None | None | False | None | False | 11820.0 | 0 | 3263022 | 113029 | None | Chapter-5 P.No 20 It.No 5.42.1 | Fabricating supplying and mounting MS box made out
.SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with
7tanks treatment with powder coated paint and finally finished with approved colour etc., complete.
14 SWG
| Sq CM | 0.62 | 0.62 | 65000.0 | False | None | None | False | None | False | 40300.0 | 0 | 3263023 | 113029 | None | Chapter-5 P.No 15 It.No 5.40.2 | Supplying . A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete
250 A 4 x 30 x 10 mm Aluminium Strips
| Rmtr | 4255.97 | 4255.97 | 6.0 | False | None | None | False | None | False | 25535.82 | 0 | 3263024 | 113029 | None | Chapter-5 P.No 20 It.No 5.41.1 | Supplying and fixing angle iron frame work fabricated out of
M.S. angle iron. and M.S. Flat.with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint.40 x 40 x 6 mm
| Rmtr | 377.9 | 377.9 | 8.0 | False | None | None | False | None | False | 3023.2 | 0 | 3263025 | 113029 | None | Chapter-5 P.No 17 It.No 5.15.11 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.Incomers
160 A 25 kA
| Each | 16660.83 | 16660.83 | 1.0 | False | None | None | False | None | False | 16660.83 | 0 | 3263026 | 113029 | None | Chapter-5 P.No 17 It.No 5.18.7 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.
6-32 A TPN
| Each | 2127.36 | 2127.36 | 14.0 | False | None | None | False | None | False | 29783.04 | 0 | 3263027 | 113029 | None | Chapter-5 P.No 19 It.No 5.38 | Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz
12/24V D.C. | Each | 638.09 | 638.09 | 3.0 | False | None | None | False | None | False | 1914.27 | 0 | 3263028 | 113029 | None | Chapter-5 P.No 18 It.No 5.22 | Supplying, fixing and wiring 0 to 600V 96x96mm AC
Voltmeter on existing panel/wood board. | Each | 560.03 | 560.03 | 1.0 | False | None | None | False | None | False | 560.03 | 0 | 3263029 | 113029 | None | Chapter-5 P.No 18 It.No 5.21 | Supplying, fixing and wiring earth leakage relay with core
balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board. | Each | 11466.95 | 11466.95 | 3.0 | False | None | None | False | None | False | 34400.85 | 0 | 3263030 | 113029 | None | Chapter-5 P.No 18 It.No 5.26 | Supplying, fixing and wiring 0 to 1500A CT operated AC analog
type Ammeter without CT | Each | 594.72 | 594.72 | 1.0 | False | None | None | False | None | False | 594.72 | 0 | 3263031 | 113029 | None | Chapter-5 P.No 18 It.No 5.27 | Supplying, fixing and wiring rotary selector switch suitable
for Ammeter | Each | 247.8 | 247.8 | 1.0 | False | None | None | False | None | False | 247.8 | 0 | 3263032 | 113029 | None | Chapter-5 P.no 19 It.No 5.28 | Supplying, fixing and wiring rotary selector switch suitable
for Voltmeter
| Each | 198.24 | 198.24 | 1.0 | False | None | None | False | None | False | 198.24 | 0 | 3263033 | 113029 | None | Chapter-5 P.No 19 It.N0 5.29 | Supplying, fixing and wiring 3 Phase Digital Ammeter /
Voltmeter | Each | 1765.58 | 1765.58 | 1.0 | False | None | None | False | None | False | 1765.58 | 0 | 3263034 | 113029 | None | Chapter-2 P.No 5 It.No2.3.2 | Wiring for lighting/power circuit using one of FRLS PVC
insulated 1100V grade, multistrand copper wire with low
conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.
1.5 mm2
| Rmtr | 32.21 | 32.21 | 35.0 | False | None | None | False | None | False | 1127.35 | 0 | 3263035 | 113029 | None | Chapter-2 P.No 5 It.No 2.3.3 | Wiring for lighting/power circuit using one of FRLS PVC
insulated 1100V grade, multistrand copper wire with low
conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.
2.5 mm2
| Rmtr | 52.04 | 52.04 | 55.0 | False | None | None | False | None | False | 2862.2 | 0 | 3263036 | 113029 | None | Chapter-5 P.No 20 It.No 5.42.1 | Fabricating supplying and mounting MS box made out
.SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with
7tanks treatment with powder coated paint and finally finished with approved colour etc., complete.
14 SWG
| Sq CM | 0.62 | 0.62 | 445800.0 | False | None | None | False | None | False | 276396.0 | 0 | 3263037 | 113029 | None | Chapter-5 P.No 20 It.No 5.40.1 | Supplying . A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete
100 A 4 x 30 x 6 mm Aluminium Strips
| Rmtr | 3054.14 | 3054.14 | 12.0 | False | None | None | False | None | False | 36649.68 | 0 | 3263038 | 113029 | None | Chapter-5 P.no 17 IT.NO 5.18.7 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.
6-32 A TPN
| Each | 2127.36 | 2127.36 | 24.0 | False | None | None | False | None | False | 51056.64 | 0 | 3263039 | 113029 | None | Chapter-5 P.no 18 IT.NO 5.18.9 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.
50-63 A TPN
| Each | 3826.03 | 3826.03 | 12.0 | False | None | None | False | None | False | 45912.36 | 0 | 3263040 | 113029 | None | Chapter-5 P.No 18 It.No 5.20.8 | Supplying, fixing and wiring Earth Leakage Miniature Circuit
Breaker (ELMCB) 240/450V upto 300mA sensitivity on existing wood/panel board.
32-40 A 4 pole
| Each | 6377.13 | 6377.13 | 6.0 | False | None | None | False | None | False | 38262.78 | 0 | 3263041 | 113029 | None | Chapter-5 P.No 19 It.No 5.38 | Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz
12/24V D.C. | Each | 638.09 | 638.09 | 18.0 | False | None | None | False | None | False | 11485.62 | 0 | 3263042 | 113029 | None | Chapter-5 P.No 18 It.No 5.22 | Supplying, fixing and wiring 0 to 600V 96x96mm AC
Voltmeter on existing panel/wood board. | Each | 560.03 | 560.03 | 18.0 | False | None | None | False | None | False | 10080.54 | 0 | 3263043 | 113029 | None | Chapter-5 P.No 18 It.No 5.21 | Supplying, fixing and wiring earth leakage relay with core
balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board. | Each | 11466.95 | 11466.95 | 18.0 | False | None | None | False | None | False | 206405.1 | 0 | 3263044 | 113029 | None | Chapter-5 P.No 18 It.No 5.26 | Supplying, fixing and wiring 0 to 1500A CT operated AC analog
type Ammeter without CT | Each | 594.72 | 594.72 | 18.0 | False | None | None | False | None | False | 10704.96 | 0 | 3263045 | 113029 | None | Chapter-5 P.No 19 It.no 5.27 | Supplying, fixing and wiring rotary selector switch suitable
for Ammeter | Each | 247.8 | 247.8 | 18.0 | False | None | None | False | None | False | 4460.4 | 0 | 3263046 | 113029 | None | Chapter-5 P.No 19 It.No 5.28 | Supplying, fixing and wiring rotary selector switch suitable
for Voltmeter | Each | 198.24 | 198.24 | 18.0 | False | None | None | False | None | False | 3568.32 | 0 | 3263047 | 113029 | None | Chapter-5 P.No 19 It.No 5.29 | Supplying, fixing and wiring 3 Phase Digital Ammeter /
Voltmeter | Each | 1765.58 | 1765.58 | 18.0 | False | None | None | False | None | False | 31780.44 | 0 | 3263048 | 113029 | None | Chapter-2 P.No 5 It.No 2.3.2 | Wiring for lighting/power circuit using one of FRLS PVC
insulated 1100V grade, multistrand copper wire with low
conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.
1.5 mm2
| Rmtr | 32.21 | 32.21 | 480.0 | False | None | None | False | None | False | 15460.8 | 0 | 3263049 | 113029 | None | Chapter-2 P.No 5 It.No 2.3.3 | Wiring for lighting/power circuit using one of FRLS PVC
insulated 1100V grade, multistrand copper wire with low
conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.
2.5 mm2
| Rmtr | 52.04 | 52.04 | 360.0 | False | None | None | False | None | False | 18734.4 | 0 | 3263050 | 113029 | None | Chapter-2 P.No 6 It.No 2.3.7 | Wiring for lighting/power circuit using one of FRLS PVC
insulated 1100V grade, multistrand copper wire with low
conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.
16 mm2 | Rmtr | 394.0 | 394.0 | 240.0 | False | None | None | False | None | False | 94560.0 | 0 | 3263051 | 113029 | None | Chapter-3 P.No 9 It.No 3.6.10 | 16A Three Way 5 Pin Socket
| No | 292.4 | 292.4 | 6.0 | False | None | None | False | None | False | 1754.4 | 0 | 3263052 | 113029 | None | Chapter-5 P.No 20 It.No 5.42.1 | Fabricating supplying and mounting MS box made out
.SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with
7tanks treatment with powder coated paint and finally finished with approved colour etc., complete.
14 SWG
| Sq CM | 0.62 | 0.62 | 126000.0 | False | None | None | False | None | False | 78120.0 | 0 | 3263053 | 113029 | None | Chapter-5 P.No 20 It.No 5.40.4 | Supplying . A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete
600 A 4 x 75 x 10 mm Aluminium Strips
| Rmtr | 6969.38 | 6969.38 | 30.0 | False | None | None | False | None | False | 209081.4 | 0 | 3263054 | 113029 | None | Chapter-5 P.No 20 It.No 5.41.2 | Supplying and fixing angle iron frame work fabricated out of
M.S. angle iron. and M.S. Flat.with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint.50 x 50 x 6 mm
| Rmtr | 489.41 | 489.41 | 24.0 | False | None | None | False | None | False | 11745.84 | 0 | 3263055 | 113029 | None | Chapter-5 P.no 17 It.No 5.15.13 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.
250 A 36 kA
| Each | 26503.45 | 26503.45 | 3.0 | False | None | None | False | None | False | 79510.35 | 0 | 3263056 | 113029 | None | Chapter-5 P.No 17 It.No 5.18.7 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.
6-32 A TPN
| Each | 2127.36 | 2127.36 | 36.0 | False | None | None | False | None | False | 76584.96 | 0 | 3263057 | 113029 | None | Chapter-5 P.No 17 It.No 5.15.7 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.
100 A 25 kA
| Each | 10515.39 | 10515.39 | 6.0 | False | None | None | False | None | False | 63092.34 | 0 | 3263058 | 113029 | None | Chapter-5 P.No 19 It.No 5.38 | Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz
12/24V D.C. | Each | 638.09 | 638.09 | 9.0 | False | None | None | False | None | False | 5742.81 | 0 | 3263059 | 113029 | None | Chapter-5 P.No 18 It.No 5.22 | Supplying, fixing and wiring 0 to 600V 96x96mm AC
Voltmeter on existing panel/wood board. | Each | 560.03 | 560.03 | 3.0 | False | None | None | False | None | False | 1680.09 | 0 | 3263060 | 113029 | None | Chapter-5 P.No 18 It.No 5.21 | Supplying, fixing and wiring earth leakage relay with core
balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board. | Each | 11466.95 | 11466.95 | 3.0 | False | None | None | False | None | False | 34400.85 | 0 | 3263061 | 113029 | None | Chapter-5 P.No 18 It.No 5.26 | Supplying, fixing and wiring 0 to 1500A CT operated AC analog
type Ammeter without CT | Each | 594.72 | 594.72 | 3.0 | False | None | None | False | None | False | 1784.16 | 0 | 3263062 | 113029 | None | Chapter-5 P.no19 It.No 5.27 | Supplying, fixing and wiring rotary selector switch suitable
for Ammeter
| Each | 247.8 | 247.8 | 3.0 | False | None | None | False | None | False | 743.4 | 0 | 3263063 | 113029 | None | Chapter-5 P.No 19 It.No 5.28 | Supplying, fixing and wiring rotary selector switch suitable
for Voltmeter | Each | 198.24 | 198.24 | 3.0 | False | None | None | False | None | False | 594.72 | 0 | 3263064 | 113029 | None | Chapter-5 P.No 19 It.No 5.29 | Supplying, fixing and wiring 3 Phase Digital Ammeter /
Voltmeter | Each | 1765.58 | 1765.58 | 3.0 | False | None | None | False | None | False | 5296.74 | 0 | 3263065 | 113029 | None | Chapter-2 P.No 5 It.no 2.3.2 | Wiring for lighting/power circuit using one of FRLS PVC
insulated 1100V grade, multistrand copper wire with low
conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.
1.5 mm2
| Rmtr | 32.21 | 32.21 | 165.0 | False | None | None | False | None | False | 5314.65 | 0 | 3263066 | 113029 | None | Chapter-2 P.No 5 It.No 2.3.3 | Wiring for lighting/power circuit using one of FRLS PVC
insulated 1100V grade, multistrand copper wire with low
conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.
2.5 mm2
| Rmtr | 52.04 | 52.04 | 225.0 | False | None | None | False | None | False | 11709.0 | 0 | 3263067 | 113029 | None | Chapter-2 P.no 6 It.No 2.3.7 | Wiring for lighting/power circuit using one of FRLS PVC
insulated 1100V grade, multistrand copper wire with low
conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.
16 mm2
| Rmtr | 394.0 | 394.0 | 255.0 | False | None | None | False | None | False | 100470.0 | 0 | 3263068 | 113029 | None | Chapter-5 P.No 20 P.No 5.42.1 | Fabricating supplying and mounting MS box made out
.SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with
7tanks treatment with powder coated paint and finally finished with approved colour etc., complete.
14 SWG
| Sq CM | 0.62 | 0.62 | 32000.0 | False | None | None | False | None | False | 19840.0 | 0 | 3263069 | 113029 | None | Chapter-5 P.No 20 It.No 5.40.2 | Supplying . A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete
250 A 4 x 30 x 10 mm Aluminium Strips
| Rmtr | 4255.97 | 4255.97 | 6.0 | False | None | None | False | None | False | 25535.82 | 0 | 3263070 | 113029 | None | Chapter-5 P.No 20 It.No 5.41.1 | Supplying and fixing angle iron frame work fabricated out of
M.S. angle iron. and M.S. Flat.with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint.40 x 40 x 6 mm
| Rmtr | 377.9 | 377.9 | 5.0 | False | None | None | False | None | False | 1889.5 | 0 | 3263071 | 113029 | None | Chapter-5 P.No 17 It.No 5.15.15 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.
250 A 35 KA
| Each | 29172.26 | 29172.26 | 1.0 | False | None | None | False | None | False | 29172.26 | 0 | 3263072 | 113029 | None | Chapter-5 P.No 18 It.No5.20.4 | Supplying, fixing and wiring Residual current circuit breaker
(RCCB) 240/450V upto 300mA sensitivity on existing wood/
panel board.
32-40A 2 pole
| Each | 5648.6 | 5648.6 | 8.0 | False | None | None | False | None | False | 45188.8 | 0 | 3263073 | 113029 | None | Chapter-5 P.No 17 It.No 5.15.9 | Supplying, fixing and wiring Residual current circuit breaker
(RCCB) 240/450V upto 300mA sensitivity on existing wood/
panel board.
100 A 25 kA
| Each | 10515.39 | 10515.39 | 3.0 | False | None | None | False | None | False | 31546.17 | 0 | 3263074 | 113029 | None | Chapter-5 P.no 19 It.No 5.38 | Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz
12/24V D.C. | Each | 638.09 | 638.09 | 3.0 | False | None | None | False | None | False | 1914.27 | 0 | 3263075 | 113029 | None | Chapter-5 P.No 18 It.No 5.22 | Supplying, fixing and wiring 0 to 600V 96x96mm AC
Voltmeter on existing panel/wood board. | Each | 560.03 | 560.03 | 1.0 | False | None | None | False | None | False | 560.03 | 0 | 3263076 | 113029 | None | Chapter-5 P.No 18 It.No 5.21 | Supplying, fixing and wiring earth leakage relay with core
balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board. | Each | 11466.95 | 11466.95 | 1.0 | False | None | None | False | None | False | 11466.95 | 0 | 3263077 | 113029 | None | Chapter-5 P.No 18 It.No 5.26 | Supplying, fixing and wiring 0 to 1500A CT operated AC analog
type Ammeter without CT | Each | 594.72 | 594.72 | 1.0 | False | None | None | False | None | False | 594.72 | 0 | 3263078 | 113029 | None | Chapter-5 P.No 19 It.No 5.27 | Supplying, fixing and wiring rotary selector switch suitable
for Ammeter | Each | 247.8 | 247.8 | 1.0 | False | None | None | False | None | False | 247.8 | 0 | 3263079 | 113029 | None | Chapter-5 P.No 19 It.no 5.28 | Supplying, fixing and wiring rotary selector switch suitable
for Voltmeter | Each | 198.24 | 198.24 | 1.0 | False | None | None | False | None | False | 198.24 | 0 | 3263080 | 113029 | None | Chapter-5 P.no 19 It.No 5.29 | Supplying, fixing and wiring 3 Phase Digital Ammeter /
Voltmeter
| Each | 1889.48 | 1889.48 | 1.0 | False | None | None | False | None | False | 1889.48 | 0 | 3263081 | 113029 | None | Chapter-2 P.No 5 It.No 2.3 | Wiring for lighting/power circuit using one of FRLS PVC
insulated 1100V grade, multistrand copper wire with low
conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.
1.5 mm2
| Rmtr | 32.21 | 32.21 | 45.0 | False | None | None | False | None | False | 1449.45 | 0 | 3263082 | 113029 | None | Chapter-2 P.No 5 It.No 2.3.3 | Wiring for lighting/power circuit using one of FRLS PVC
insulated 1100V grade, multistrand copper wire with low
conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.
2.5 mm2
| Rmtr | 52.04 | 52.04 | 25.0 | False | None | None | False | None | False | 1301.0 | 0 | 3263083 | 113029 | None | Chapter-2 P.no 6 It.no 2.3.7 | Wiring for lighting/power circuit using one of FRLS PVC
insulated 1100V grade, multistrand copper wire with low
conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.
16 mm2
| Rmtr | 394.0 | 394.0 | 45.0 | False | None | None | False | None | False | 17730.0 | 0 | 3263084 | 113029 | None | Chapter-5 P.No 20 It.No 5.42.1 | Fabricating supplying and mounting MS box made out
.SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with
7tanks treatment with powder coated paint and finally finished with approved colour etc., complete.
14 SWG
| Sq CM | 0.62 | 0.62 | 85000.0 | False | None | None | False | None | False | 52700.0 | 0 | 3263085 | 113029 | None | Chapter-5 P.No 20 It.No 5.40.2 | Supplying . A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete
250 A 4 x 30 x 10 mm Aluminium Strips
| Rmtr | 4255.97 | 4255.97 | 8.0 | False | None | None | False | None | False | 34047.76 | 0 | 3263086 | 113029 | None | Chapter-5 P.no 20 It.No 5.41.1 | Supplying and fixing angle iron frame work fabricated out of
M.S. angle iron. and M.S. Flat.with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint.
40 x 40 x 6 mm
| Rmtr | 377.9 | 377.9 | 6.0 | False | None | None | False | None | False | 2267.4 | 0 | 3263087 | 113029 | None | Chapter-5 P.No 17 It.No 5.15.11 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.
| Each | 16660.83 | 16660.83 | 1.0 | False | None | None | False | None | False | 16660.83 | 0 | 3263088 | 113029 | None | Chapter-5 P.No 18 It.No 5.18.9 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.
50-63 A TPN
| Each | 3826.03 | 3826.03 | 14.0 | False | None | None | False | None | False | 53564.42 | 0 | 3263089 | 113029 | None | Chapter-5 P.No 19 It.No 5.38 | Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz
12/24V D.C. | Each | 638.09 | 638.09 | 3.0 | False | None | None | False | None | False | 1914.27 | 0 | 3263090 | 113029 | None | Chapter-5 P.No 18 It.No 5.22 | Supplying, fixing and wiring 0 to 600V 96x96mm AC
Voltmeter on existing panel/wood board. | Each | 560.03 | 560.03 | 1.0 | False | None | None | False | None | False | 560.03 | 0 | 3263091 | 113029 | None | Chapter-5 P.No 18 It.No 5.21 | Supplying, fixing and wiring earth leakage relay with core
balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board. | Each | 11466.95 | 11466.95 | 1.0 | False | None | None | False | None | False | 11466.95 | 0 | 3263092 | 113029 | None | Chapter-5 P.No 18 It.No 5.26 | Supplying, fixing and wiring 0 to 1500A CT operated AC analog
type Ammeter without CT | Each | 247.8 | 247.8 | 1.0 | False | None | None | False | None | False | 247.8 | 0 | 3263093 | 113029 | None | Chapter-5 P.No 19 It.No 5.27 | Supplying, fixing and wiring rotary selector switch suitable
for Ammeter | Each | 247.8 | 247.8 | 1.0 | False | None | None | False | None | False | 247.8 | 0 | 3263094 | 113029 | None | Chapter-5 P.No 19 It.No5.28 | Supplying, fixing and wiring rotary selector switch suitable
for Voltmeter | Each | 198.24 | 198.24 | 1.0 | False | None | None | False | None | False | 198.24 | 0 | 3263095 | 113029 | None | Chapter-5 P.No 19 It.No 5.29 | Supplying, fixing and wiring 3 Phase Digital Ammeter /
Voltmeter | Each | 1765.58 | 1765.58 | 1.0 | False | None | None | False | None | False | 1765.58 | 0 | 3263096 | 113029 | None | Chapter-2 P.No 5 It.No 2.3.2 | Wiring for lighting/power circuit using one of FRLS PVC
insulated 1100V grade, multistrand copper wire with low
conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.
1.5 mm2
| Rmtr | 32.21 | 32.21 | 55.0 | False | None | None | False | None | False | 1771.55 | 0 | 3263097 | 113029 | None | Chapter-2 P.No 5 It.No 2.3.3 | Wiring for lighting/power circuit using one of FRLS PVC
insulated 1100V grade, multistrand copper wire with low
conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.
2.5 mm2
| Rmtr | 52.04 | 52.04 | 75.0 | False | None | None | False | None | False | 3903.0 | 0 | 3263098 | 113029 | None | Chapter-2 P.No 5 It.No 2.3.7 | Wiring for lighting/power circuit using one of FRLS PVC
insulated 1100V grade, multistrand copper wire with low
conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.
16 mm2
| Rmtr | 394.0 | 394.0 | 95.0 | False | None | None | False | None | False | 37430.0 | 0 | 3263099 | 113029 | None | Chapter-5 P.No 20 It.No 5.42.1 | Fabricating supplying and mounting MS box made out
.SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with
7tanks treatment with powder coated paint and finally finished with approved colour etc., complete.14 SWG
| Sq CM | 0.62 | 0.62 | 58000.0 | False | None | None | False | None | False | 35960.0 | 0 | 3263100 | 113029 | None | Chapter-5 P.No 20 It.No 5.40.1 | Supplying . A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete
100 A 4 x 30 x 6 mm Aluminium Strips | Rmtr | 3054.14 | 3054.14 | 12.0 | False | None | None | False | None | False | 36649.68 | 0 | 3263101 | 113029 | None | Chapter-5 P.No 20 it.No 5.41.1 | Supplying and fixing angle iron frame work fabricated out of
M.S. angle iron. and M.S. Flat.with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint.40 x 40 x 6 mm
| Rmtr | 377.9 | 377.9 | 8.0 | False | None | None | False | None | False | 3023.2 | 0 | 3263102 | 113029 | None | Chapter-5 p.No 17 It.no 5.15.11 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.160 A 25 KA
| Each | 16660.83 | 16660.83 | 1.0 | False | None | None | False | None | False | 16660.83 | 0 | 3263103 | 113029 | None | Chapter-5 P.no 17 It.No 5.15.9 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.
100 A 25 KA
| Each | 10515.39 | 10515.39 | 1.0 | False | None | None | False | None | False | 10515.39 | 0 | 3263104 | 113029 | None | Chapter-5 p.no 17 It.No 5.18.4 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.
6-32 A DP
| Each | 915.62 | 915.62 | 4.0 | False | None | None | False | None | False | 3662.48 | 0 | 3263105 | 113029 | None | Chapter-5 P.No 18 It.No 5.18.9 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.
50-63 A TPN
| Each | 3826.03 | 3826.03 | 3.0 | False | None | None | False | None | False | 11478.09 | 0 | 3263106 | 113029 | None | Chapter-5P.No 19 It.No 5.38 | Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz
12/24V D.C. | Each | 638.09 | 638.09 | 3.0 | False | None | None | False | None | False | 1914.27 | 0 | 3263107 | 113029 | None | Chapter-5 P.No 19 It.No5.22 | Supplying, fixing and wiring 0 to 600V 96x96mm AC
Voltmeter on existing panel/wood board.
| Each | 560.03 | 560.03 | 1.0 | False | None | None | False | None | False | 560.03 | 0 | 3263108 | 113029 | None | Chapter-5 P.No 19 It.No 5.21 | Supplying, fixing and wiring earth leakage relay with core
balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board. | Each | 11466.95 | 11466.95 | 1.0 | False | None | None | False | None | False | 11466.95 | 0 | 3263109 | 113029 | None | Chapter-5 P.No 18 It.No 5.26 | Supplying, fixing and wiring 0 to 1500A CT operated AC analog
type Ammeter without CT | Each | 594.72 | 594.72 | 1.0 | False | None | None | False | None | False | 594.72 | 0 | 3263110 | 113029 | None | Chapter-5 p.no 19 it.no 5.27 | Supplying, fixing and wiring rotary selector switch suitable
for Ammeter | Each | 247.8 | 247.8 | 1.0 | False | None | None | False | None | False | 247.8 | 0 | 3263111 | 113029 | None | Chapter-5 P.No 19 It.No 5.28 | Supplying, fixing and wiring rotary selector switch suitable
for Voltmeter
| Each | 198.24 | 198.24 | 1.0 | False | None | None | False | None | False | 198.24 | 0 | 3263112 | 113029 | None | Chapter-5 P.no 19 It.No 5.29 | Supplying, fixing and wiring 3 Phase Digital Ammeter /
Voltmeter | Each | 1765.58 | 1765.58 | 1.0 | False | None | None | False | None | False | 1765.58 | 0 | 3263113 | 113029 | None | Chapter-2 p.No 5 It.No 2.3.2 | Wiring for lighting/power circuit using one of FRLS PVC
1.5 mm2
| Rmtr | 32.21 | 32.21 | 35.0 | False | None | None | False | None | False | 1127.35 | 0 | 3263114 | 113029 | None | Chapter-2 P.No 5 It.No 2.3.3 | Wiring for lighting/power circuit using one of FRLS PVC
insulated 1100V grade, multistrand copper wire with low
conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.
2.5 mm2
| Rmtr | 52.04 | 52.04 | 48.0 | False | None | None | False | None | False | 2497.92 | 0 | 3263115 | 113029 | None | Chapter-2 P.No 5 It.No 2.3.7 | Wiring for lighting/power circuit using one of FRLS PVC
insulated 1100V grade, multistrand copper wire with low
conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.
16 mm2
| Rmtr | 394.0 | 394.0 | 65.0 | False | None | None | False | None | False | 25610.0 | 0 | 3263116 | 113029 | None | Chapter-5 P.No 20 It.No 5.42.1 | Fabricating supplying and mounting MS box made out
.SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with
7tanks treatment with powder coated paint and finally finished with approved colour etc., complete.
14 SWG
| Sq CM | 0.62 | 0.62 | 525000.0 | False | None | None | False | None | False | 325500.0 | 0 | 3263117 | 113029 | None | Chapter-5 P.No 20 It.No 5.40.2 | Supplying . A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete
1000 A double run of 4x60x10 mm Aluminium Strips
| Rmtr | 13108.62 | 13108.62 | 25.0 | False | None | None | False | None | False | 327715.5 | 0 | 3263118 | 113029 | None | Chapter-5 P.No 20 It.No 5.41.3 | Supplying and fixing angle iron frame work fabricated out of
M.S. angle iron. and M.S. Flat.with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint.75 x 75 x 6 mm
| Rmtr | 687.65 | 687.65 | 45.0 | False | None | None | False | None | False | 30944.25 | 0 | 3263119 | 113029 | None | Chapter-5 P.No 17 It.No 5.15.18 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.
400-500 A 50KA
| Each | 51414.78 | 51414.78 | 1.0 | False | None | None | False | None | False | 51414.78 | 0 | 3263120 | 113029 | None | Chapter-5 P.No 17 P.No 5.15.18 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.
160 A 25 kA
| Each | 15569.27 | 15569.27 | 4.0 | False | None | None | False | None | False | 62277.08 | 0 | 3263121 | 113029 | None | Chapter-5 P.No 17 It.No 5.15.14 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.
200 A 35 kA
| Each | 26544.34 | 26544.34 | 2.0 | False | None | None | False | None | False | 53088.68 | 0 | 3263122 | 113029 | None | Chapter-5 P.No 17 It.No 5.15.9 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.
100 A 25 kA
| Each | 10515.39 | 10515.39 | 5.0 | False | None | None | False | None | False | 52576.95 | 0 | 3263123 | 113029 | None | Chapter-5 P.No 17 It.No 5.15.10 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.
125 A 25KA
| Each | 12812.5 | 12812.5 | 2.0 | False | None | None | False | None | False | 25625.0 | 0 | 3263124 | 113029 | None | Chapter-5 P.No 18 It.N0 5.18.9 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.
50-63 A TPN
| Each | 3826.03 | 3826.03 | 4.0 | False | None | None | False | None | False | 15304.12 | 0 | 3263125 | 113029 | None | Chapter-5 P.no 17 It.No 5.18.1 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.
6-32 A SP
| Each | 514.19 | 514.19 | 3.0 | False | None | None | False | None | False | 1542.57 | 0 | 3263126 | 113029 | None | Chapter-5 P.No 19 It.No 5.38 | Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz
12/24V D.C. | Each | 638.09 | 638.09 | 3.0 | False | None | None | False | None | False | 1914.27 | 0 | 3263127 | 113029 | None | Chapter-5 P.No 18 It.No 5.22 | Supplying, fixing and wiring 0 to 600V 96x96mm AC
Voltmeter on existing panel/wood board. | Each | 560.03 | 560.03 | 1.0 | False | None | None | False | None | False | 560.03 | 0 | 3263128 | 113029 | None | Chapter-5 P.No18 It.No 5.21 | Supplying, fixing and wiring earth leakage relay with core
balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board. | Each | 11466.95 | 11466.95 | 1.0 | False | None | None | False | None | False | 11466.95 | 0 | 3263129 | 113029 | None | Chapter-5 P.No 18 It.No 5.26 | Supplying, fixing and wiring 0 to 1500A CT operated AC analog
type Ammeter without CT | Each | 594.72 | 594.72 | 1.0 | False | None | None | False | None | False | 594.72 | 0 | 3263130 | 113029 | None | Chapter-5 P.No 19 It.No 5.28 | Supplying, fixing and wiring rotary selector switch suitable
for Voltmeter
| Each | 198.24 | 198.24 | 1.0 | False | None | None | False | None | False | 198.24 | 0 | 3263131 | 113029 | None | Chapter-5 P.no 19 It,No 5.29 | Supplying, fixing and wiring 3 Phase Digital Ammeter /
Voltmeter | Each | 1765.58 | 1765.58 | 1.0 | False | None | None | False | None | False | 1765.58 | 0 | 3263132 | 113029 | None | Chapter-2 P.No 5 It.No 2.3.2 | Wiring for lighting/power circuit using one of FRLS PVC
insulated 1100V grade, multistrand copper wire with low
conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.
1.5 mm2
| Rmtr | 32.21 | 32.21 | 148.0 | False | None | None | False | None | False | 4767.08 | 0 | 3263133 | 113029 | None | Chapter-2 P.No 5 It.No 2.3.3 | Wiring for lighting/power circuit using one of FRLS PVC
insulated 1100V grade, multistrand copper wire with low
conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.
2.5 mm2
| Rmtr | 52.04 | 52.04 | 95.0 | False | None | None | False | None | False | 4943.8 | 0 | 3263134 | 113029 | None | Chapter-5 P.No 20 It.No 5.42.1 | Fabricating supplying and mounting MS box made out
.SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with
7tanks treatment with powder coated paint and finally finished with approved colour etc., complete.
14 SWG
| Sq CM | 0.62 | 0.62 | 32000.0 | False | None | None | False | None | False | 19840.0 | 0 | 3263135 | 113029 | None | Chapter-5 P.No 20 It.No 5.40.1 | Supplying . A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete
100 A 4 x 30 x 6 mm Aluminium Strips
| Rmtr | 3054.14 | 3054.14 | 8.0 | False | None | None | False | None | False | 24433.12 | 0 | 3263136 | 113029 | None | Chapter-5 P.No 20 It.N0 5.41.1 | Supplying and fixing angle iron frame work fabricated out of
M.S. angle iron. and M.S. Flat.with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint.
40 x 40 x 6 mm
| Rmtr | 377.9 | 377.9 | 6.0 | False | None | None | False | None | False | 2267.4 | 0 | 3263137 | 113029 | None | Chapter-5 P.No 17 it.No 5.15.9 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.
100 A 25 KA
| Each | 10515.39 | 10515.39 | 1.0 | False | None | None | False | None | False | 10515.39 | 0 | 3263138 | 113029 | None | Chapter-5 P.No 17 It.No 5.18 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.
40 A TPN
| Each | 3771.52 | 3771.52 | 12.0 | False | None | None | False | None | False | 45258.24 | 0 | 3263139 | 113029 | None | Chapter-5 P.No 19 It.No 5.38 | Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz
12/24V D.C. | Each | 638.09 | 638.09 | 3.0 | False | None | None | False | None | False | 1914.27 | 0 | 3263140 | 113029 | None | Chapter-5 P.No 18 It.No 5.22 | Supplying, fixing and wiring 0 to 600V 96x96mm AC
Voltmeter on existing panel/wood board.
| Each | 560.03 | 560.03 | 1.0 | False | None | None | False | None | False | 560.03 | 0 | 3263141 | 113029 | None | Chapter-5 P.No 18 It.No 5.21 | Supplying, fixing and wiring earth leakage relay with core
balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board. | Each | 11466.95 | 11466.95 | 1.0 | False | None | None | False | None | False | 11466.95 | 0 | 3263142 | 113029 | None | Chapter-5 P.No 18 It.No 5.26 | Supplying, fixing and wiring 0 to 1500A CT operated AC analog
type Ammeter without CT | Each | 594.72 | 594.72 | 1.0 | False | None | None | False | None | False | 594.72 | 0 | 3263143 | 113029 | None | Chapter-5 P.No 18 It.No 5.27 | Supplying, fixing and wiring rotary selector switch suitable
for Ammeter | Each | 247.8 | 247.8 | 1.0 | False | None | None | False | None | False | 247.8 | 0 | 3263144 | 113029 | None | Chapter-5 P.No 18 It.No 5.28 | Supplying, fixing and wiring rotary selector switch suitable
for Voltmeter | Each | 198.24 | 198.24 | 1.0 | False | None | None | False | None | False | 198.24 | 0 | 3263145 | 113029 | None | Chapter-5 P.No 8 It.No 5.29 | Supplying, fixing and wiring 3 Phase Digital Ammeter /
Voltmeter
| Each | 1765.58 | 1765.58 | 1.0 | False | None | None | False | None | False | 1765.58 | 0 | 3263146 | 113029 | None | Chapter-2 P.No 5 It.No 2.3.2 | Wiring for lighting/power circuit using one of FRLS PVC
insulated 1100V grade, multistrand copper wire with low
conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.
1.5 mm2
| Rmtr | 32.21 | 32.21 | 15.0 | False | None | None | False | None | False | 483.15 | 0 | 3263147 | 113029 | None | Chapter-2 P.No 5 It.No 2.3.3 | Wiring for lighting/power circuit using one of FRLS PVC
insulated 1100V grade, multistrand copper wire with low
conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.
2.5 mm2
| Rmtr | 52.04 | 52.04 | 20.0 | False | None | None | False | None | False | 1040.8 | 0 | 3263148 | 113029 | None | Chapter-2 P.no 5 It.No 2.3.7 | Wiring for lighting/power circuit using one of FRLS PVC
insulated 1100V grade, multistrand copper wire with low
conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.
16 mm2
| Rmtr | 394.0 | 394.0 | 15.0 | False | None | None | False | None | False | 5910.0 | 0 | 3263149 | 113029 | None | Chapter-5 P.no 14 It.N0 5.5.2 | Supplying of TPST with rewirable porcelain channels in SM enclosure. Made out of 14 SWG powder coated paint of approved colour.
63A
| Each | 5195.13 | 5195.13 | 2.0 | False | None | None | False | None | False | 10390.26 | 0 | 3263150 | 113029 | None | Chapter-5 P.no 14 It.No 5.5.3 | Supplying of TPST with rewirable porcelain channels in SM enclosure. Made out of 14 SWG powder coated paint of approved colour.
100A
| Each | 9380.47 | 9380.47 | 2.0 | False | None | None | False | None | False | 18760.94 | 0 | 3263151 | 113029 | None | Least Quotation Rate | Supplying of TPST with rewirable porcelain channels in SM enclosure. Made out of 14 SWG powder coated paint of approved colour.
160A | Each | 13865.0 | 13865.0 | 1.0 | False | None | None | False | None | False | 13865.0 | 0 | 3263152 | 113029 | None | Chapter-5 P.No 15 It.No 5.12.1 | Supplying of on load change over switches 4 poles, AC
23A Duty, 415V, 50Hz, AC Supply. With all accessories. (SM Enclosure Sheet Metal Execution)
63A
| Each | 8525.56 | 8525.56 | 1.0 | False | None | None | False | None | False | 8525.56 | 0 | 3263153 | 113029 | None | Chapter-3 P.No 9 It.No 3.13.1 | Supplying and fixing of metal clad industrial plugs and sockets
2pole+earth 250V PLUG
16A
| Each | 480.43 | 480.43 | 2.0 | False | None | None | False | None | False | 960.86 | 0 | 3263154 | 113029 | None | Chapter-3 P.no 9 It.No 3.13.2 | 32A
Supplying and fixing of metal clad industrial plugs and sockets
2pole+earth 250V PLUG
32A
| Each | 679.07 | 679.07 | 6.0 | False | None | None | False | None | False | 4074.42 | 0 | 3263155 | 113029 | None | Chapter-3 P.No 9 It.No 3.13.5 | 3pole+earth 440V PLUG
16A
| Each | 560.19 | 560.19 | 5.0 | False | None | None | False | None | False | 2800.95 | 0 | 3263156 | 113029 | None | Chapter-3 P.No 9 It.No 3.13.4 | 3pole+earth 440V PLUG
32A
| Each | 755.62 | 755.62 | 5.0 | False | None | None | False | None | False | 3778.1 | 0 | 3263157 | 113029 | None | Chapter-3 P.no 9 It.No 3.13.5 | 2pole+earth 250V SOCKET
16A
| Each | 657.87 | 657.87 | 2.0 | False | None | None | False | None | False | 1315.74 | 0 | 3263158 | 113029 | None | Chapter-3 P.no 09 It.No 3.13.6 | 2pole+earth 250V SOCKET
32A
| Each | 826.46 | 826.46 | 6.0 | False | None | None | False | None | False | 4958.76 | 0 | 3263159 | 113029 | None | Chapter-3 P.no 9 It.No 3.13.7 | 3pole+earth 440V SOCKET
16A
| Each | 785.25 | 785.25 | 5.0 | False | None | None | False | None | False | 3926.25 | 0 | 3263160 | 113029 | None | Chapter-3 P.No 10 It.No3.13.8 | 3pole+earth 440V SOCKET
32A | Each | 1025.67 | 1025.67 | 6.0 | False | None | None | False | None | False | 6154.02 | 0 | 3263161 | 113029 | None | Chapter-5 P.no 20 It.No 5.42.1 | Fabricating supplying and mounting MS box made out
.SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with
7tanks treatment with powder coated paint and finally finished with approved colour etc., complete.14 SWG
| Sq CM | 0.62 | 0.62 | 315000.0 | False | None | None | False | None | False | 195300.0 | 0 | 3263162 | 113029 | None | Chapter-5 P.No 20 It.No 5.40.5 | Supplying . A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete
1000 A double run of 4x60x10 mm Aluminium Strips
| Rmtr | 13108.62 | 13108.62 | 8.0 | False | None | None | False | None | False | 104868.96 | 0 | 3263163 | 113029 | None | Chapter-5 p.no 20 It.No 5.41.3 | Supplying and fixing angle iron frame work fabricated out of
M.S. angle iron. and M.S. Flat.with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint.
75 x 75 x 6 mm
| Rmtr | 687.65 | 687.65 | 22.0 | False | None | None | False | None | False | 15128.3 | 0 | 3263164 | 113029 | None | Chapter-5 p.no 17 It.No 5.15.18 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.
400-500 A 50KA
| Each | 51414.78 | 51414.78 | 1.0 | False | None | None | False | None | False | 51414.78 | 0 | 3263165 | 113029 | None | Chapter-5 p.no 17 It.No 5.15.11 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.
160 A 25 kA
| Each | 16660.83 | 16660.83 | 5.0 | False | None | None | False | None | False | 83304.15 | 0 | 3263166 | 113029 | None | Chapter-5 P.No 17 It.No 5.15.15 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.
250 A 35KA
| Each | 26503.45 | 26503.45 | 6.0 | False | None | None | False | None | False | 159020.7 | 0 | 3263167 | 113029 | None | Chapter-5 P.No 17 It.No 5.15.9 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.
100 A 25 kA
| Each | 10515.39 | 10515.39 | 4.0 | False | None | None | False | None | False | 42061.56 | 0 | 3263168 | 113029 | None | Chapter-5 P.No 17 It.No 5.18.1 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.
6-32 A SP
| Each | 514.19 | 514.19 | 12.0 | False | None | None | False | None | False | 6170.28 | 0 | 3263169 | 113029 | None | Chapter-5 P.no 17 It.No 5.18.9 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.
50-63 A TPN - For TVSS Connectivity
| Each | 3826.03 | 3826.03 | 4.0 | False | None | None | False | None | False | 15304.12 | 0 | 3263170 | 113029 | None | Chapter-5 P.No 19 It.No 5.38 | Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz
12/24V D.C. | Each | 638.09 | 638.09 | 3.0 | False | None | None | False | None | False | 1914.27 | 0 | 3263171 | 113029 | None | Chapter-5 P.No 18 It.No 5.22 | Supplying, fixing and wiring 0 to 600V 96x96mm AC
Voltmeter on existing panel/wood board.
| Each | 560.03 | 560.03 | 1.0 | False | None | None | False | None | False | 560.03 | 0 | 3263172 | 113029 | None | Chapter-5 P.no 18 It.No 5.21 | Supplying, fixing and wiring earth leakage relay with core
balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board.
| Each | 11466.95 | 11466.95 | 1.0 | False | None | None | False | None | False | 11466.95 | 0 | 3263173 | 113029 | None | Chapter-5 P.no 18 It.No 5.26 | Supplying, fixing and wiring 0 to 1500A CT operated AC analog
type Ammeter without CT | Each | 594.72 | 594.72 | 1.0 | False | None | None | False | None | False | 594.72 | 0 | 3263174 | 113029 | None | Chapter-5 P.no 19 It.No 5.28 | Supplying, fixing and wiring rotary selector switch suitable
for Voltmeter
| Each | 198.24 | 198.24 | 1.0 | False | None | None | False | None | False | 198.24 | 0 | 3263175 | 113029 | None | Chapter-5 P.No 19 It.No 5.29 | Supplying, fixing and wiring 3 Phase Digital Ammeter /
Voltmeter | Each | 1765.58 | 1765.58 | 1.0 | False | None | None | False | None | False | 1765.58 | 0 | 3263176 | 113029 | None | Chapter-2 P.No 5 It.No 2.3.2 | Wiring for lighting/power circuit using one of FRLS PVC
insulated 1100V grade, multistrand copper wire with low
conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.
1.5 mm2
| Rmtr | 32.21 | 32.21 | 148.0 | False | None | None | False | None | False | 4767.08 | 0 | 3263177 | 113029 | None | Chapter-2 P.no 5 It.No 2.3.3 | Wiring for lighting/power circuit using one of FRLS PVC
insulated 1100V grade, multistrand copper wire with low
conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.
2.5 mm2
| Rmtr | 52.04 | 52.04 | 95.0 | False | None | None | False | None | False | 4943.8 | 0 | 3263178 | 113029 | None | Chapter-5 P.no 20 It.No 5.42.1 | Fabricating supplying and mounting MS box made out
.SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with
7tanks treatment with powder coated paint and finally finished with approved colour etc., complete.
14 SWG
| Sq CM | 0.62 | 0.62 | 315000.0 | False | None | None | False | None | False | 195300.0 | 0 | 3263179 | 113029 | None | Chapter-5 P.No 20 It.No 5.40.5 | Supplying . A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete
1000 A double run of 4x60x10 mm Aluminium Strips
| Rmtr | 13108.62 | 13108.62 | 8.0 | False | None | None | False | None | False | 104868.96 | 0 | 3263180 | 113029 | None | Chapter-5 P.No 20 It.No 5.41.3 | Supplying and fixing angle iron frame work fabricated out of
M.S. angle iron. and M.S. Flat.with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint.
75 x 75 x 6 mm
| Rmtr | 687.65 | 687.65 | 22.0 | False | None | None | False | None | False | 15128.3 | 0 | 3263181 | 113029 | None | Chapter-5 P.No 17 It.No 5.15.18 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.
400-500 A 50KA
| Each | 51414.78 | 51414.78 | 1.0 | False | None | None | False | None | False | 51414.78 | 0 | 3263182 | 113029 | None | Chapter-5 P.No 17 It.No 5.15.11 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.160 A 25 kA
| Each | 16660.83 | 16660.83 | 5.0 | False | None | None | False | None | False | 83304.15 | 0 | 3263183 | 113029 | None | Chapter-5 P.No 17 It.No 5.15.15 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.
250 A 35KA
| Each | 26503.45 | 26503.45 | 6.0 | False | None | None | False | None | False | 159020.7 | 0 | 3263184 | 113029 | None | Chapter-5 P.No 17 It.No 5.15.9 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.
100 A 25 kA
| Each | 10515.39 | 10515.39 | 4.0 | False | None | None | False | None | False | 42061.56 | 0 | 3263185 | 113029 | None | Chapter-5 P.No 17 It.No 5.18.1 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.
6-32 A SP
| Each | 514.19 | 514.19 | 12.0 | False | None | None | False | None | False | 6170.28 | 0 | 3263186 | 113029 | None | Chapter-5 P.no 17 It.No 5.18.9 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.
50-63 A TPN - For TVSS Connectivity
| Each | 3826.03 | 3826.03 | 4.0 | False | None | None | False | None | False | 15304.12 | 0 | 3263187 | 113029 | None | Chapter-5 P.No 19 It.No 5.38 | Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz
12/24V D.C. | Each | 638.09 | 638.09 | 3.0 | False | None | None | False | None | False | 1914.27 | 0 | 3263188 | 113029 | None | Chapter-5 P.no 18 It.No 5.22 | Supplying, fixing and wiring 0 to 600V 96x96mm AC
Voltmeter on existing panel/wood board. | Each | 560.03 | 560.03 | 1.0 | False | None | None | False | None | False | 560.03 | 0 | 3263189 | 113029 | None | Chapter-5 P.No 18 It.No 5.21 | Supplying, fixing and wiring earth leakage relay with core
balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board.
| Each | 11466.95 | 11466.95 | 1.0 | False | None | None | False | None | False | 11466.95 | 0 | 3263190 | 113029 | None | Chapter-5 P.No 18 It.No 5.26 | Supplying, fixing and wiring 0 to 1500A CT operated AC analog
type Ammeter without CT
| Each | 594.72 | 594.72 | 1.0 | False | None | None | False | None | False | 594.72 | 0 | 3263191 | 113029 | None | Chapter-5 P.No 19 It.No 5.28 | Supplying, fixing and wiring rotary selector switch suitable
for Voltmeter | Each | 198.24 | 198.24 | 1.0 | False | None | None | False | None | False | 198.24 | 0 | 3263192 | 113029 | None | Chapter-5 P.No 19 It.No 5.29 | Supplying, fixing and wiring 3 Phase Digital Ammeter /
Voltmeter
| Each | 1765.58 | 1765.58 | 1.0 | False | None | None | False | None | False | 1765.58 | 0 | 3263193 | 113029 | None | Chapter-2 P.No 5 It.No 2.3.2 | Wiring for lighting/power circuit using one of FRLS PVC
insulated 1100V grade, multistrand copper wire with low
conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.
1.5 mm2
| Rmtr | 32.21 | 32.21 | 148.0 | False | None | None | False | None | False | 4767.08 | 0 | 3263194 | 113029 | None | Chapter-2 P.No 5 It.No 2.3.3 | Wiring for lighting/power circuit using one of FRLS PVC
insulated 1100V grade, multistrand copper wire with low
conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.
2.5 mm2
| Rmtr | 52.04 | 52.04 | 95.0 | False | None | None | False | None | False | 4943.8 | 0 | 3263195 | 113029 | None | Chapter-5 P.no 20 It.No 5.42.1 | Fabricating supplying and mounting MS box made out
.SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with
7tanks treatment with powder coated paint and finally finished with approved colour etc., complete.
14 SWG
| Sq CM | 0.62 | 0.62 | 85000.0 | False | None | None | False | None | False | 52700.0 | 0 | 3263196 | 113029 | None | Chapter-5 P.No 20 It.No 5.40.2 | Supplying . A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete
250 A 4 x 30 x 10 mm Aluminium Strips
| Rmtr | 4255.97 | 4255.97 | 22.0 | False | None | None | False | None | False | 93631.34 | 0 | 3263197 | 113029 | None | Chapter-5 P.No 15 It.No 5.41.1 | Supplying and fixing angle iron frame work fabricated out of
M.S. angle iron. and M.S. Flat.with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint.
40 x 40 x 6 mm
| Rmtr | 359.9 | 359.9 | 16.0 | False | None | None | False | None | False | 5758.4 | 0 | 3263198 | 113029 | None | Chapter-5 P.No 17 It.No 5.15.14 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.
200 A 35 kA
| Each | 26544.34 | 26544.34 | 1.0 | False | None | None | False | None | False | 26544.34 | 0 | 3263199 | 113029 | None | Chapter-5 P.no 17 It.No 5.15.9 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.
100 A 25 kA
| Each | 10515.39 | 10515.39 | 1.0 | False | None | None | False | None | False | 10515.39 | 0 | 3263200 | 113029 | None | Chapter-5 P.No 17 It.No 5.15.18 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.
160 A 25 kA
| Each | 15569.27 | 15569.27 | 1.0 | False | None | None | False | None | False | 15569.27 | 0 | 3263201 | 113029 | None | Chapter-5 P.No 17 It.No 5.18.7 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.
6-32 A TPN
| Each | 2127.36 | 2127.36 | 1.0 | False | None | None | False | None | False | 2127.36 | 0 | 3263202 | 113029 | None | Chapter-5 P.18 It.no 5.18.9 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.
50-63 A TPN
| Each | 3826.03 | 3826.03 | 2.0 | False | None | None | False | None | False | 7652.06 | 0 | 3263203 | 113029 | None | Chapter-5 P.No 19 It.No 5.38 | Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz
12/24V D.C. | Each | 638.09 | 638.09 | 3.0 | False | None | None | False | None | False | 1914.27 | 0 | 3263204 | 113029 | None | Chapter-5 P.No 18 It.No 5.22 | Supplying, fixing and wiring 0 to 600V 96x96mm AC
Voltmeter on existing panel/wood board.
| Each | 560.03 | 560.03 | 1.0 | False | None | None | False | None | False | 560.03 | 0 | 3263205 | 113029 | None | Chapter-5 P.No 18 It.No5.21 | Supplying, fixing and wiring earth leakage relay with core
balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board. | Each | 11466.95 | 11466.95 | 1.0 | False | None | None | False | None | False | 11466.95 | 0 | 3263206 | 113029 | None | Chapter-5 P.No 18 It.No 5.26 | Supplying, fixing and wiring 0 to 1500A CT operated AC analog
type Ammeter without CT
| Each | 594.72 | 594.72 | 1.0 | False | None | None | False | None | False | 594.72 | 0 | 3263207 | 113029 | None | Chapter-5 P.No 19 It.No 5.28 | Supplying, fixing and wiring rotary selector switch suitable
for Voltmeter
| Each | 198.24 | 198.24 | 1.0 | False | None | None | False | None | False | 198.24 | 0 | 3263208 | 113029 | None | Chapter-5 P.No 19 It.No 5.29 | Supplying, fixing and wiring 3 Phase Digital Ammeter /
Voltmeter | Each | 1765.58 | 1765.58 | 1.0 | False | None | None | False | None | False | 1765.58 | 0 | 3263209 | 113029 | None | Chapter-2 P.No 5 It.No 2.3.2 | Wiring for lighting/power circuit using one of FRLS PVC
insulated 1100V grade, multistrand copper wire with low
conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.1.5 mm2
| Rmtr | 32.21 | 32.21 | 148.0 | False | None | None | False | None | False | 4767.08 | 0 | 3263210 | 113029 | None | Chapter-2 P.No 5 It.No 2.3.3 | Wiring for lighting/power circuit using one of FRLS PVC
insulated 1100V grade, multistrand copper wire with low
conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.
2.5 mm2
| Rmtr | 52.04 | 52.04 | 95.0 | False | None | None | False | None | False | 4943.8 | 0 | 3263211 | 113029 | None | Chapter-2 P.No 6 It.No 2.3.7 | Wiring for lighting/power circuit using one of FRLS PVC
insulated 1100V grade, multistrand copper wire with low
conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.
16 mm2
| Rmtr | 394.0 | 394.0 | 65.0 | False | None | None | False | None | False | 25610.0 | 0 | 3263212 | 113029 | None | ESCOM - 2023-24 P.No 13 It.No 32.03 | Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975 ( BESCOM SR - 2021-2022 )
10 Sqmm, 4 Core.
| Km | 146206.96 | 146206.96 | 0.6 | False | None | None | False | None | False | 87724.176 | 0 | 3263213 | 113029 | None | ESCOM - 2023-24 P.No 13 It.No 32.05 | Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975 ( BESCOM SR - 2021-2022 )
| Km | 175742.24 | 175742.24 | 0.7 | False | None | None | False | None | False | 123019.568 | 0 | 3263214 | 113029 | None | ESCOM - 2023-24 P.No 13 It.No 32.09 | Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975 ( BESCOM SR - 2021-2022 )
35 Sqmm, 3.5 Core.
| Km | 190882.82 | 190882.82 | 0.5 | False | None | None | False | None | False | 95441.41 | 0 | 3263215 | 113029 | None | ESCOM - 2023-24 P.No 13 It.No 32.11 | Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975 ( BESCOM SR - 2021-2022 )
50 Sqmm, 3.5 Core.
| Km | 221747.55 | 221747.55 | 0.4 | False | None | None | False | None | False | 88699.02 | 0 | 3263216 | 113029 | None | ESCOM - 2023-24 P.No 13 It.No 32.13 | Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975 ( BESCOM SR - 2021-2022 )
70 Sqmm, 3.5 Core.
| Km | 393892.97 | 393892.97 | 0.3 | False | None | None | False | None | False | 118167.891 | 0 | 3263217 | 113029 | None | ESCOM - 2023-24 P.No 13 It.No 32.14 | Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975 ( BESCOM SR - 2021-2022 )
95 Sqmm, 3.5 Core.
| Km | 462413.39 | 462413.39 | 0.3 | False | None | None | False | None | False | 138724.017 | 0 | 3263218 | 113029 | None | ESCOM - 2023-24 P.No 13 It.No 32.15 | Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975 ( BESCOM SR - 2021-2022 )
120 Sqmm, 3.5 Core.
| Km | 566085.47 | 566085.47 | 0.4 | False | None | None | False | None | False | 226434.188 | 0 | 3263219 | 113029 | None | ESCOM - 2023-24 P.No 13 It.No 32.16 | Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975 ( BESCOM SR - 2021-2022 )
150 Sqmm, 3.5 Core.
| Km | 687217.55 | 687217.55 | 0.5 | False | None | None | False | None | False | 343608.775 | 0 | 3263220 | 113029 | None | ESCOM - 2023-24 P.No 13 It.No 32.17 |
Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975 ( BESCOM SR - 2021-2022 )
185 Sqmm, 3.5 Core.
| Km | 856419.1 | 856419.1 | 0.9 | False | None | None | False | None | False | 770777.19 | 0 | 3263221 | 113029 | None | ESCOM - 2023-24 P.No 13 It.No 32.18 | Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975 ( BESCOM SR - 2021-2022 )
240 Sqmm, 3.5 Core.
| Km | 1068843.17 | 1068843.17 | 1.8 | False | None | None | False | None | False | 1923917.706 | 0 | 3263222 | 113029 | None | ESCOM- 2023-24 P.No 52 It.No 21.05 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as
directed by the departmental staff
2.5 to 25 Sqmm
| Km | 25877.75 | 25877.75 | 1.3 | False | None | None | False | None | False | 33641.075 | 0 | 3263223 | 113029 | None | ESCOM- 2023-24 P.No 52 It.No 21.06 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as
directed by the departmental staff
35 to 95 Sqmm
| Km | 38581.22 | 38581.22 | 1.5 | False | None | None | False | None | False | 57871.83 | 0 | 3263224 | 113029 | None | ESCOM- 2023-24 P.No 52 It.No 1.07 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as
directed by the departmental staff
120 to 240 Sqmm
| Km | 39993.44 | 39993.44 | 3.6 | False | None | None | False | None | False | 143976.384 | 0 | 3263225 | 113029 | None | Chapter-6 P.No 42 It.No 6.11.1 | Supplying and fixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) (42/6.11) ( SR 2019-2020 )
19/20mm
| Each | 84.25 | 84.25 | 56.0 | False | None | None | False | None | False | 4718.0 | 0 | 3263226 | 113029 | None | Chapter-6 P.No 42 It.No 6.11.2 | Supplying and fixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) (42/6.11) ( SR 2019-2020 )
25mm dia
| Each | 104.08 | 104.08 | 68.0 | False | None | None | False | None | False | 7077.44 | 0 | 3263227 | 113029 | None | Chapter-6 P.No 42 It.No 6.11.3 | Supplying and fixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) (42/6.11) ( SR 2019-2020 )
32mm dia
| Each | 144.96 | 144.96 | 52.0 | False | None | None | False | None | False | 7537.92 | 0 | 3263228 | 113029 | None | Chapter-7 P.No 43 It.No6.11.4 | Supplying and fixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) (42/6.11) ( SR 2019-2020 )
45mm dia
| Each | 240.37 | 240.37 | 70.0 | False | None | None | False | None | False | 16825.9 | 0 | 3263229 | 113029 | None | Chapter-8 P.No 4 It.No 6.11.5 | Supplying and fixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) (42/6.11) ( SR 2019-2020 )
50mm dia
| Each | 315.95 | 315.95 | 86.0 | False | None | None | False | None | False | 27171.7 | 0 | 3263230 | 113029 | None | Chapter-6 P.No 43 It.No 6.13 | Supplying Bitumen Compound and covering the cable joint pot heads ( SR 2019-2020 )
| Per Kg | 101.6 | 101.6 | 12.0 | False | None | None | False | None | False | 1219.2 | 0 | 3263231 | 113029 | None | Chapter-6 P.No 43 It.No 6.14 | Supplying Epoxy Resin and covering the cable Joint ( SR 2019-2020 )
| Per Kg | 1077.93 | 1077.93 | 12.0 | False | None | None | False | None | False | 12935.16 | 0 | 3263232 | 113029 | None | ESCOM- 2023-24 P.No 20 It.No 63.02 | Heavy Duty Copper Terminal Long Barrel
35 Sqmm Copper Terminal, Apprx Wt: 17 Gm
| No | 49.56 | 49.56 | 62.0 | False | None | None | False | None | False | 3072.72 | 0 | 3263233 | 113029 | None | ESCOM- 2023-24 P.No 20 It.No 63.03 | Heavy Duty Copper Terminal Long Barrel
50 Sqmm Copper Terminal, Apprx Wt: 26 Gm
| No | 71.86 | 71.86 | 72.0 | False | None | None | False | None | False | 5173.92 | 0 | 3263234 | 113029 | None | ESCOM- 2023-24 P.No 20 It.No 63.04 | Heavy Duty Copper Terminal Long Barrel
70 Sqmm Copper Terminal, Apprx Wt: 38 Gm
| No | 110.27 | 110.27 | 82.0 | False | None | None | False | None | False | 9042.14 | 0 | 3263235 | 113029 | None | ESCOM- 2023-24 P.No 20 It.No 63.05 | Heavy Duty Copper Terminal Long Barrel
95 Sqmm Copper Terminal, Apprx Wt: 58 Gm
| No | 159.83 | 159.83 | 54.0 | False | None | None | False | None | False | 8630.82 | 0 | 3263236 | 113029 | None | ESCOM- 2023-24 P.No 20 It.No 63.06 | Heavy Duty Copper Terminal Long Barrel
120 Sqmm Copper Terminal, Apprx Wt: 64 Gm
| No | 173.46 | 173.46 | 68.0 | False | None | None | False | None | False | 11795.28 | 0 | 3263237 | 113029 | None | ESCOM- 2023-24 P.No 20 It.No 63.10 | Heavy Duty Copper Terminal Long Barrel
240 Sqmm Copper Terminal, Apprx Wt: 218 Gm
| No | 439.85 | 439.85 | 132.0 | False | None | None | False | None | False | 58060.2 | 0 | 3263238 | 113029 | None | Chapter-6 P.No 43 It.No 6.18 | Supplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc. ( SR 2019-2020 )
8 SWG GI Wire
| Rmtr | 23.54 | 23.54 | 800.0 | False | None | None | False | None | False | 18832.0 | 0 | 3263239 | 113029 | None | Chapter-6 P.No 43 It.No 6.18.6 | Supplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc. ( SR 2019-2020 )
8 SWG Copper wire.
| Rmtr | 130.1 | 130.1 | 1100.0 | False | None | None | False | None | False | 143110.0 | 0 | 3263240 | 113029 | None | Chapter-12 P.No 54 It.No 12.56 | Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40mm dia 2.90mm thick GI pipe 2.5 mtr long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia.
| Each | 4348.89 | 4348.89 | 22.0 | False | None | None | False | None | False | 95675.58 | 0 | 3263241 | 113029 | None | Chapter-12 P.No 54 It.No 12.57 | Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc. using 40mm dia 2.9mm thick 2.5 mtr long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode.The funnel should be enclosed in a CC chamber of 400x400x400mm with a cast iron cover. The earth electrode shall have staggered holes of 12mm dia and the electrode should be covered 150mm all-round with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts.
| Each | 5237.18 | 5237.18 | 24.0 | False | None | None | False | None | False | 125692.32 | 0 | 3263242 | 113029 | None | Chapter-12 P.No 54 It.No 12.58.3 | GI/Copper strips for grounding connections, using necessary fixing materials as required.
25x6mm GI strip
| Rmtr | 158.59 | 158.59 | 1150.0 | False | None | None | False | None | False | 182378.5 | 0 | 3263243 | 113029 | None | Chapter-12 P.No 55 It.No 12.58.6 | GI/Copper strips for grounding connections, using necessary fixing materials as required.
600x600x3mm GI Plate
| Each | 1084.13 | 1084.13 | 28.0 | False | None | None | False | None | False | 30355.64 | 0 | 3263244 | 113029 | None | Chapter-12 P.No 55 It.No 12.58.7 | Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc. using 40mm dia 2.9mm thick 2.5 mtr long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode.The funnel should be enclosed in a CC chamber of 400x400x400mm with a cast iron cover. The earth electrode shall have staggered holes of 12mm dia and the electrode should be covered 150mm all-round with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts.
25x3mm Copper strip
| Rmtr | 706.23 | 706.23 | 520.0 | False | None | None | False | None | False | 367239.6 | 0 | 3263245 | 113029 | None | Chapter-12 P.No 55 It.No 12.58.11 | GI/Copper strips for grounding connections, using necessary fixing materials as required.
600x600x3mm Copper plate
| Each | 9194.62 | 9194.62 | 26.0 | False | None | None | False | None | False | 239060.12 | 0 | 3263246 | 113029 | None | Least Quotation Rate | Supply and installation of ESE lightning air
terminal with the below technical
Parameters.
Stainless Steel material (304 L)
suitable for corrosive
Environments.
dT = 15 micro seconds. METU lab tested as per NF C
17-102 (2011) standard.
Lightning current = 100 KA
(10/350 micro sec) tested. Protection radius = 107 Meter
CPRI TESTED | Each | 100300.0 | 100300.0 | 2.0 | False | None | None | False | None | False | 200600.0 | 0 | 3263247 | 113029 | None | Least Quotation Rate | Supply and installation of GI Mast Pole 5-meter
length with below accessories
GI Mast pole 5 meter 01
No
GI Base Plate 1feetx1feet HDP Adaptor 01 No
Guy Wire kit- 20 meter
Anchor Fastener 04 Nos
Guy Wire Hook 03 Nos
| Each | 38645.0 | 38645.0 | 2.0 | False | None | None | False | None | False | 77290.0 | 0 | 3263248 | 113029 | None | Least Quotation Rate | Supply and installation of lightning event counter
with the below technical
parameters.
6 digits Counter
Non re-settable
Electromechanical display IP 65 protection (IEC 529)
Lightning Current of 100 KA
| Each | 27730.0 | 27730.0 | 2.0 | False | None | None | False | None | False | 55460.0 | 0 | 3263249 | 113029 | None | Least Quotation Rate | Supply and installation of Test link box with
copper test link inside the IP 65
protected box | Each | 5805.6 | 5805.6 | 2.0 | False | None | None | False | None | False | 11611.2 | 0 | 3263250 | 113029 | None | Least Quotation Rate | COPPER EARTH KITMAINTENANCE FREE ADVANCE EARTHING
Supply of Maintenance free earthing system of 01 no of
Copper Earth rod 17.2mm with flat terminal connection
EARTH ROD SPECIFICATION
Technology = Copper Bonded Rod
Length of the electrode = 2000 mm / 2 Mtrs
Rod Dia= 17.2mm Dia
BACK FILL COMPOUND Supply of Earthing back fill
compound manufactured as per complying with the
international standard IEEE 802000.
Earthing Chemical
compound is certified from BIS & NABL accredited laboratory
as per IEEE 80-2000 (Clause 14.5d).
Certification - Test certificate from BIS (Bureau of Indian
Standards), Govt of India accredited laboratory confirming
the contents.
* IEEE80-2000 standard - Test certificate from
NABL, BIS, DGS&D, MOEF, DGQA accredited
laboratory as per IEEE80-2000 - clause 14.5 d.
* Moisture retaining capacity (pH Value) -Between 7 to 7.2
* ROHS certified.
* Weight = 25KG BAG"
| Each | 15930.0 | 15930.0 | 4.0 | False | None | None | False | None | False | 63720.0 | 0 | 3263251 | 113029 | None | Chapter-1 P.No 2 It.no 1.5.1 | Supplying and fixing PVC/metal conduit deep junction box .
19/20mm deep junction box
| Each | 60.71 | 60.71 | 1300.0 | False | None | None | False | None | False | 78923.0 | 0 | 3263252 | 113029 | None | Chapter-1 P.No 3 It.No 1.5.2 | Supplying and fixing PVC/metal conduit deep junction box .
25mm deep junction box
| Each | 69.38 | 69.38 | 1700.0 | False | None | None | False | None | False | 117946.0 | 0 | 3263253 | 113029 | None | Chapter-1 P.No 3 It.No 1.5.3 | Supplying and fixing PVC/metal conduit deep junction box .
32mm deep junction box
| Each | 75.58 | 75.58 | 310.0 | False | None | None | False | None | False | 23429.8 | 0 | 3263254 | 113029 | None | Chapter-5 P.No 17 It.No 5.17.2 | Supplying and fixing regular MCCB distribution Panel
confirming to IS/IEC 61439 - 3 and IK09 tested as per IS/IEC
62262 with minimum IP43 protection provided with
Polyurethane (PUR) gasket, with suitable earthing system, on
wall/wood board/flush mounting using required cl A , bolts,
nuts, etc., with provision for fixing of suitable type capacity
MCCB's as an incomer for 3 phase Double door with necessary
bus bar completely wired to use on 440V 3phase 4 wire powder
coated painting etc., complete with a provision for fixing of
single/three phase suitable capacity MCB's as outgoings
confirming to IS/IEC 60898 - 2.
8 Way
| Each | 15617.6 | 15617.6 | 2.0 | False | None | None | False | None | False | 31235.2 | 0 | 3263255 | 113029 | None | Chapter-11 P.No 44 It.No 11.5.1 | Supply of round/square recess/surface mounted rolling
type LED Down light with . W GU 10 LED Lamp Rib
Fabricated from diecast aluminium with white powder
coated prewired to mains connector & has swivelling unit of
aluminium die cast eye ball & LED Lamp position retained by
circular wire spring, with Life of 25000 burning hours & 70%
lumen maintenance with CRI 80. Power Input: 220-240V
@50/60Hz & Power factor 0.9 along with CE approved. 2years
Warranty against any manufacturing defect working under
standard electrical condition
LED square or round down light 5-6W
| Each | 997.4 | 997.4 | 95.0 | False | None | None | False | None | False | 94753.0 | 0 | 3263256 | 113029 | None | Chapter-11 P.No 45 it.No 11.6.3 | Supplying of recess mounting non integral type . LED w
luminaire comprising of pressure decast/extruded aluminium
housing, with spring loaded false ceiling clA, Power LEDs with
CCT 6500 degree K, CRI 70%. efficacy 100 lumen per W,
120degree beam spread, life 25000 burning hours and
Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The
lamp compartment is enclosed with anti glare opal diffuser
which enhances the lighting level LEDs are driven by HF
electronic driver integrated in a separate control gear
assembly., with PF 0.95, power loss should 5% of lamp
Wage., short circuit & open circuit protection to be integrated
in the circuit, THD less than 20%, Life as per LM 79. The
operating input voltage should be between 130 to 275 V. BIS
Approved and Tested by NABL/CPRI accredited laboratory
with 2 years Warranty against any manufacturing defect
working under standard electrical condition.
LED modular down light 1'x1' - 24W
| Each | 4574.39 | 4574.39 | 50.0 | False | None | None | False | None | False | 228719.5 | 0 | 3263257 | 113029 | None | Chapter-11 P.No 43 It.No 11.2.1 | Supplying & fixing retrofit type-PL- LED Lamp . W LED
linear source with CCT 6500 degree K, CRI 70%. efficacy
80 lumen per W,
life 25000 burning hours and
Compliance to IS 10322/IEC 60598, LM 79 & LM 80.
The LED are driven by HF electronic driver integrated in the
system, with PF 0.95, power loss should 5% of lamp
Wage., short circuit & open circuit protection to be integrated
in the circuit, THD less than 20%, Life as per LM 79. The
operating input voltage should be between 130 to275 V.
Tested by NABL/CPRI accredited laboratory with 2 years
Warranty against any manufacturing defect working under
standard electrical condition.
8-9 W
| Each | 771.9 | 771.9 | 42.0 | False | None | None | False | None | False | 32419.8 | 0 | 3263258 | 113029 | None | Chapter-11 P.No 43 It.No 11.2.3 | Supplying & fixing retrofit type-PL- LED Lamp . W LED
linear source with CCT 6500 degree K, CRI 70%. efficacy
80 lumen per W,
life 25000 burning hours and
Compliance to IS 10322/IEC 60598, LM 79 & LM 80.
The LED are driven by HF electronic driver integrated in the
system, with PF 0.95, power loss should 5% of lamp
Wage., short circuit & open circuit protection to be integrated
in the circuit, THD less than 20%, Life as per LM 79. The
operating input voltage should be between 130 to275 V.
Tested by NABL/CPRI accredited laboratory with 2 years
Warranty against any manufacturing defect working under
standard electrical condition.
18-22W
| Each | 869.78 | 869.78 | 66.0 | False | None | None | False | None | False | 57405.48 | 0 | 3263259 | 113029 | None | Least Quotation Rate | Supplying & fixing of Model : - EASY GEN - 2300
| Each | 165200.0 | 165200.0 | 1.0 | False | None | None | False | None | False | 165200.0 | 0 | 3263260 | 113029 | None | Chapter-5 P.No 18 It.No 5.26 | Supplying, fixing and wiring 0 to 1500A CT operated AC analog
type Ammeter without CT | Each | 594.72 | 594.72 | 2.0 | False | None | None | False | None | False | 1189.44 | 0 | 3263261 | 113029 | None | Chapter-5 P.No 18 It.No 5.26 | Supplying, fixing and wiring 0 to 1500A CT operated AC analog
type Ammeter without CT | Each | 594.72 | 594.72 | 2.0 | False | None | None | False | None | False | 1189.44 | 0 | 3263262 | 113029 | None | Chapter-5 P.No 18 It.No 5.27 | Supplying, fixing and wiring rotary selector switch suitable
for Ammeter | Each | 247.8 | 247.8 | 2.0 | False | None | None | False | None | False | 495.6 | 0 | 3263263 | 113029 | None | Chapter-5 P.No 17 It.No 5.15.20 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.
700-800 A 50KA
| Each | 61826.1 | 61826.1 | 4.0 | False | None | None | False | None | False | 247304.4 | 0 | 3263264 | 113029 | None | Chapter-5 P.No 17 It.No 5.15.18 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.
400-500 A 50KA
| Each | 51414.78 | 51414.78 | 5.0 | False | None | None | False | None | False | 257073.9 | 0 | 3263265 | 113029 | None | Chapter-5 P.No 17 It.No 5.15.11 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.
160 A 25 kA
| Each | 16660.83 | 16660.83 | 6.0 | False | None | None | False | None | False | 99964.98 | 0 |
|
|
---|