tenderSubEstimateList | createdTs | version | createdDate | modifiedDate | workCategoryName | subEstimateName | estimateTotal | itemList |
---|
1718079599000 | 1 | None | None | Buildings | Demolishing & Re-construction of 4 Class rooms to Govt. HRPS at Dhangarwadi in Basavakalyan Taluka | 4076834.2 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3263872 | 113059 | None | PWD SR-2023-24 Vol. 2 P. No. 187, Item No. 19.3 | Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable
material to the appropriate disposal area as per direction ofEngineer-in-charge. | Cum | 2547.3 | 2547.3 | 21.4 | False | None | None | False | None | False | 54512.22 | 0 | 3263873 | 113059 | None | PWD SR-2023-24, Vol. 2 P. No. 187, Item No. 19.9 | Demolishing stone rubble masonry manually/ by mechanical
means including stacking of serviceable material and disposal of
unserviceable material to the appropriate disposal area as per
direction of Engineerin- charge | Cum | 831.6 | 831.6 | 127.0 | False | None | None | False | None | False | 105613.2 | 0 | 3263874 | 113059 | None | PWD SR-2023-24, Vol. 1 P. No. 8, Item No. 1.12 | Earth work in surface excavation by mechanical means for
lowering & leveling the ground for all works other than
foundation in all kinds of soils & upto depth not exceeding
300mm as per drawing and technical specifications, including
setting out, shoring, strutting, barricading, caution lights,
removal of stumps and other deleterious matter including
dressing of excavated surfaces, disposing off or levelling the
excavated earth or sorting & stacking the selected earth for reuse
in a radius of 50 m and lift upto 1.5 m including cost of labour,
tools, usage of machinery & other appurtenances required to
complete the work | Cum | 99.75 | 99.75 | 45.0 | False | None | None | False | None | False | 4488.75 | 0 | 3263875 | 113059 | None | PWD SR-2023-24, Vol. 1 P. No. 8, Item No. 1.15.1 | Earth work excavation for Foundation by mechanical means for
all works & depth upto 3 m, as per drawing and technical
specifications, including setting out, shoring, strutting,
barricading, caution lights, including dressing of excavated
surfaces, disposing off or levelling the excavated earth or sorting
& stacking the selected earth for reuse in a radius of 50 m and
lift upto 1.5 m including cost of labour, tools, usage of
machinery & other appurtenaces required to complete the work
In ordinary/soft rock without blasting upto 1.5 m depth | Cum | 381.15 | 381.15 | 130.8 | False | None | None | False | None | False | 49854.42 | 0 | 3263876 | 113059 | None | PWD SR-2023-24, Vol. 1 P. No. 15, Item No. 2.1.2 | Providing and laying in position plain cement concrete for
levelling course for all works in foundation. The
granite/trap/basalt crushed graded coarse aggregates and fine
aggregates as per relevant IS Codes machine mixed, laid in
layers not exceeding 150 mm thickness, well compacted using
plate vibrators, including all lead & lifts, cost of all materials of
quality, labour, Usage charges of machineries, curing, and all the
other appurtenances required to complete the work as per
technical specifications Mix 1:4:8 (M5) Using 40 mm nominal
size graded crushed coarse aggregates | Cum | 5947.2 | 5947.2 | 13.31 | False | None | None | False | None | False | 79157.232 | 0 | 3263877 | 113059 | None | PWD SR-2023-24, Vol. 1 P. No. 15, Item No. 2.2.1, | Providing and laying in position Reinforced cement concrete for
all Foundation works. The ranite/trap/basalt crushed graded
coarse aggregates and fine aggregates as per relevant IS Codes
machine mixed with super plasticizers laid in finished layers,
well compacted using needle vibrators, including all lead & lifts,
cost of all materials, quality confirming to the requirements of
relevant IS codes , labour, Usage charges of machinery, curing
and all the other appurtenances required to complete the work
as per technical specifications. M20 Design Mix Using 20 mm
nominal size graded crushed coarse aggregates | Cum | 6601.35 | 6601.35 | 24.05 | False | None | None | False | None | False | 158762.4675 | 0 | 3263878 | 113059 | None | PWD SR-2023-24, Vol. 1 P. No. 15, Item No. 2.2.1 | Centering & Shuttering charges for footing | Cum | 198.04 | 198.04 | 24.06 | False | None | None | False | None | False | 4764.8424 | 0 | 3263879 | 113059 | None | PWD SR-2023-24, Vol. 1 P. No. 16, Item No. 2.4.2, | Providing and laying in position Reinforced cement concrete for
all Sub structures of building works. The ranite/trap/basalt
crushed graded coarse aggregates and fine aggregates as per
relevant IS Codes machine mixed with super plasticizers laid in
finished layers, well compacted using needle vibrators,
including all lead & lifts, cost of all materials, quality confirming
to the requirements of relevant IS codes , labour, Usage charges
of machinery, curing and all the other appurtenances required
to complete the work as per technical specifications. M20 Design
Mix Using 20 mm nominal size graded crushed coarse
aggregates | Cum | 6639.15 | 6639.15 | 12.58 | False | None | None | False | None | False | 83520.507 | 0 | 3263880 | 113059 | None | P. No. 16, Item No. 2.4.2, | Centering & Shuttering charges for Columns | Cum | 4647.41 | 4647.41 | 4.81 | False | None | None | False | None | False | 22354.0421 | 0 | 3263881 | 113059 | None | Vol. 1 P. No. 16, Item No. 2.4.2, | Centering & Shuttering charges for Plinth beams | Cum | 3319.58 | 3319.58 | 7.77 | False | None | None | False | None | False | 25793.1366 | 0 | 3263882 | 113059 | None | PWD SR-2023-24, Vol. 1 P. No. 16, Item No. 2.5.1, | Providing and laying in position Reinforced cement concrete for
all Super structures of building , Road works, Water works,
Irrigation works & super structure works of bridges upto 3.50 m
height. The granite/trap/basalt crushed graded coarse
aggregates and fine aggregates as per relevant IS Codes machine
mixed with super plasticisers laid in layers, well compacted
using needle vibrators. The cost includes all lead & lifts, cost of
all materials, quality confirming to the requirements of relevant
IS codes , labour, Usage charges of machinery, curing and all
other purtenances required to complete the work as per
technical specifications. M20 Design Mix Using 20 mm nominal
size graded crushed coarse aggregates | Cum | 6961.5 | 6961.5 | 51.46 | False | None | None | False | None | False | 358238.79 | 0 | 3263883 | 113059 | None | Vol. 1 P. No. 16, Item No. 2.5.1, | Centering & Shuttering charges for Columns | Cum | 4873.05 | 4873.05 | 7.02 | False | None | None | False | None | False | 34208.811 | 0 | 3263884 | 113059 | None | Vol. 1 P. No. 16, Item No. 2.5.1, | Centering & Shuttering charges for Lintel & Beams | Cum | 4176.9 | 4176.9 | 14.49 | False | None | None | False | None | False | 60523.281 | 0 | 3263885 | 113059 | None | Vol. 1 P. No. 16, Item No. 2.5.1, | Centering & Shuttering charges for Roof Slab | Cum | 3480.75 | 3480.75 | 29.28 | False | None | None | False | None | False | 101916.36 | 0 | 3263886 | 113059 | None | Vol. 1 P. No. 16, Item No. 2.5.1, | Centering & Shuttering charges for Chajja | Cum | 3132.68 | 3132.68 | 0.65 | False | None | None | False | None | False | 2036.242 | 0 | 3263887 | 113059 | None | PWD SR-2023-24 Vol. 1 P. No. 18, Item No. 2.11 (a) | Supplying, fitting and placing TMT FE 550 / 550D Steel
Reinforcement including cost of all materials, machinery, labour,
cleaning, straightening, cutting, bending, hooking,
laping/welding joints, tying with binding wire / soft annealed
steel wire and other ancilary operations complete as per
drawing and technical specification | Cum | 93929.85 | 93929.85 | 7.95 | False | None | None | False | None | False | 746742.3075 | 0 | 3263888 | 113059 | None | PWD SR-2023-24, Vol. 2 P. No. 9, Item No. 5.1.1, | Providing Random rubble masonry with hard stone in
foundation and plinth including levelling up with cement
concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone
aggregate 20 mm nominal size) upto plinth level with : Cement
mortar 1:6 (1 cement : 6 coarse sand) | Cum | 5891.55 | 5891.55 | 32.62 | False | None | None | False | None | False | 192182.361 | 0 | 3263889 | 113059 | None | PWD SR-2023-24, Vol. 2 P. No. 9, Item No. 5.4, Rs | Providing Size Stone masonry with hard stone in foundation &
plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 6708.45 | 6708.45 | 30.09 | False | None | None | False | None | False | 201857.2605 | 0 | 3263890 | 113059 | None | PWD SR-2023-24, Vol. 1 P. No. 7, Item No. 1.11, | Filling available excavated earth (excluding rock) in trenches,
plinth, sides of foundations and other similar works etc. in
layers not exceeding 20cm in depth, consolidating each
deposited layer by ramming and watering, lead up to 50 m and
lift upto 1.5 m. | Cum | 454.65 | 454.65 | 164.85 | False | None | None | False | None | False | 74949.0525 | 0 | 3263891 | 113059 | None | PWD SR-2023-24, Vol. 2 P. No. 14, Item No. 6.8, | Providing Brick work with common burnt clay Non Modular
bricks of class designation 3.5 in superstructure above plinth
level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6
coarse sand) including cost of all materials, labour, scaffolding
and usage charges of machinery & other incidental charges
complete as per the direction of engineer incharge of work. | Cum | 8367.45 | 8367.45 | 56.05 | False | None | None | False | None | False | 468995.5725 | 0 | 3263892 | 113059 | None | PWD SR-2023-24, Vol. 2 P. No. 100, Item No. 12.13 | Providing Salwood frames of doors, windows, clerestory
windows, ventilators and other frames, wrought, framed or
assembled including making plaster groves (excluding cost of
cement concrete and side clamps), but including cost of
materials, labour, usage charges complete as per specifications. | Cum | 103755.75 | 103755.75 | 1.2 | False | None | None | False | None | False | 124506.9 | 0 | 3263893 | 113059 | None | PWD SR-2023-24, Vol. 2 P. No. 104, Item No. 12.51 | Fixing of door frame in an existing opening including
embedding frame in floor and walls after cutting masonry for
holdfasts for embedding holdfast in cement concrete 1:3:6 of
20mm and down size granite metal painting two coats of coal tar
to sides of frame, making good the damages to walls and floor
as required and disposal of the debris with lead upto 50 m.
including cost of materials, labour charges, complete as per
specifications. | No | 1066.8 | 1066.8 | 4.0 | False | None | None | False | None | False | 4267.2 | 0 | 3263894 | 113059 | None | PWD SR-2023-24, Vol. 2 P. No. 104, Item No. 12.52 | Fixing of window frame in an existing opening including
embedding frame in floor and walls after cutting masonry for
holdfasts for embedding holdfast in cement concrete 1:3:6 of
20mm and down size granite metal painting two coats of coal tar
to sides of frame, making good the damages to walls and floor
as required and disposal of the debris with lead upto 50 m.
including cost of materials, labour charges, complete as per
specifications. | No | 811.65 | 811.65 | 12.0 | False | None | None | False | None | False | 9739.8 | 0 | 3263895 | 113059 | None | PWD SR-2023-24, Vol. 2 P. No. 100, Item No. 12.21 | Providing and fixing in position fully panelled Matti/Nandi
wood shutters for doors with , stiles and rails of 30mm. thick
with bottom and lock rails 180mm wide top rail and stiles
100mm wide as per drawing and panels of 25mm thick
including cost of materials, labour, usage charges complete as
per specifications. (excluding cost of fixtures) | Sqm | 6029.1 | 6029.1 | 8.82 | False | None | None | False | None | False | 53176.662 | 0 | 3263896 | 113059 | None | PWD SR-2023-24, Vol. 2 P. No. 101, Item No. 12.32 | Providing and fixing in position Mathi / Nandi wood fully
panelled shutters for windows with stiles and rails of 25mm.
thick, 75mm wide in two halves with panels of 20mm thick
including cost of materials, labour charges, usage charges
complete as per specifications. (excluding cost of fixtures) | Sqm | 4060.35 | 4060.35 | 21.6 | False | None | None | False | None | False | 87703.56 | 0 | 3263897 | 113059 | None | PWD SR-2023-24, Vol. 2 P. No. 86, Item No. 11.34B | Providing and fixing M.S. grills of required pattern in frames of
windows etc. with M.S. flats, square or round bars etc. including
priming coat with approved steel primer all complete. Fixed to
openings /wooden frames with rawl plugs screws etc. | Kgs | 192.15 | 192.15 | 453.6 | False | None | None | False | None | False | 87159.24 | 0 | 3263898 | 113059 | None | PWD SR-2023-24, Vol. 2 P. No. 43, Item No. 8.10, | Providing 6 mm cement plaster with cement mortar 1:3 (1
cement : 3 fine sand) on concrete surface / ceilings including
rounding off corners wherever required smooth rendering,
providing and removing scaffolding, including cost of materials,
labour, curing complete as per specifications | Sqm | 221.55 | 221.55 | 205.0 | False | None | None | False | None | False | 45417.75 | 0 | 3263899 | 113059 | None | PWD SR-2023-24, Vol. 2 P. No. 41, Item No. 8.1.1, | Providing 12 mm cement plaster with cement mortar 1:4 (1
cement: 4 fine sand) to brick masonry including rounding off
corners wherever required smooth rendering, providing and
removing scaffolding, including cost of materials, labour, curing
complete as per specifications and as per directions of Engineerin-
charge | Sqm | 267.75 | 267.75 | 301.52 | False | None | None | False | None | False | 80731.98 | 0 | 3263900 | 113059 | None | PWD SR-2023-24, Vol. 2 P. No. 50, Item No. 8.51, | Providing and applying white cement based putty of average
thickness 1 mm, of approved brand and manufacturer, over the
plastered wall surface to prepare the surface even and smooth
complete as per specifications and as per directions of Engineer
in charge. | Sqm | 105.0 | 105.0 | 442.32 | False | None | None | False | None | False | 46443.6 | 0 | 3263901 | 113059 | None | PWD SR-2023-24, Vol. 2 P. No. 41, Item No. 8.2.1, | Providing 15 mm cement plaster on the rough side of single or
half brick wall of mix 1:4 (1 cement: 4 fine sand) including
rounding off corners wherever required smooth rendering,
providing and removing scaffolding, including cost of materials,
labour, curing complete as per specifications and as per
directions of Engineer-in-charge | Sqm | 309.75 | 309.75 | 406.04 | False | None | None | False | None | False | 125770.89 | 0 | 3263902 | 113059 | None | Vol. 2 P. No. 41, Item No. 8.2.1, | Providing and laying in position plain cement concrete for
levelling course for all works in foundation. The
granite/trap/basalt crushed graded coarse aggregates and fine
aggregates as per relevant IS Codes machine mixed, laid in
layers not exceeding 150 mm thickness, well compacted using
plate vibrators, including all lead & lifts, cost of all materials of
quality, labour, Usage charges of machineries, curing, and all the
other appurtenances required to complete the work as per
technical specifications Mix 1:3:6 (M10) Using 40 mm nominal
size graded crushed coarse aggregates | Cum | 6288.45 | 6288.45 | 15.92 | False | None | None | False | None | False | 100112.124 | 0 | 3263903 | 113059 | None | PWD SR-2023-24, Vol. 2 P. No. 61, Item No. 9.17.2 | Providing and laying Vitrified tiles in different sizes (thickness
to be specified by manufacturer), with water absorption less
than 0.08 % and conforming to I.S. 15622, of approved make, in
all colours & shade, over 12 mm thick bed of cement mortar 1:3
(1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3
kg/ m2 including grouting the joint with white cement &
matching pigments etc. complete | Sqm | 1233.75 | 1233.75 | 230.04 | False | None | None | False | None | False | 283811.85 | 0 | 3263904 | 113059 | None | PWD SR-2023-24, Vol. 2 P. No. 44, Item No. 8.21, | Providing White washing with lime to give an even shade :New
work (three coats) with lime of approved quality, including cost
of materials, labour complete as per specifications and as per
directions of Engineerin-in
charge. | Sqm | 27.3 | 27.3 | 205.0 | False | None | None | False | None | False | 5596.5 | 0 | 3263905 | 113059 | None | PWD SR-2023-24, Vol. 2 P. No. 45, Item No. 8.25, | Distempering with oil bound washable distemper of approved
brand and manufacture to give an even shade :New work (two
coats) over and including water thinnable priming coat with
cement primer after thoroughly brooming the surface to remove
all dirt, dust, mortar drops and foreign matter including
preparing the surface even and sand paper smooth, cost of
materials, labour complete as per specifications and as per
directions of Engineer-in-charge. | Sqm | 143.85 | 143.85 | 301.52 | False | None | None | False | None | False | 43373.652 | 0 | 3263906 | 113059 | None | PWD SR-2023-24, Vol. 2 P. No. 46, Item No. 8.30, | Finishing walls with Acrylic Smooth exterior paint of required
shade :New work (Two coat applied @ 1.67 ltr/10 m² over and
including priming coat of exterior primer applied @ 2.20 kg/10
m²) with paint of approved quality to give an even shade, after
thoroughly brooming the surface to remove all dirt, dust, mortar
drops and foreign matter including preparing the surface even
and sand paper smooth, cost of materials, labour complete as
per specifications and as per directions of Engineer-in-charge. | Sqm | 182.7 | 182.7 | 406.04 | False | None | None | False | None | False | 74183.508 | 0 | 3263907 | 113059 | None | PWD SR-2023-24, Vol. 2 P. No. 46, Item No. 8.33.2 | Painting wood work with Deluxe Multi Surface Paint of
required shade. Two coat applied @ 0.90 ltr/10 m² over an under
coat of primer applied @0.75 ltr/10 m² of approved brand and
manufacture to give an even shade including preparing the
surface after thorougly cleaning oil, grease, dirt and foreign
matter, sand papering and knotting , cost of
materials, labour complete as per specifications | Sqm | 144.9 | 144.9 | 71.28 | False | None | None | False | None | False | 10328.472 | 0 | 3263908 | 113059 | None | PWD SR-2023-24, Vol. 2 P. No. 47, Item No. 8.33.3 | Painting Steel work with Deluxe Multi Surface Paint to give an
even shade. Two coat applied @ 0.90 ltr/10 m² over an under
coat of primer applied @ 0.80 ltr/10 m² of approved brand and
manufacture including preparing the surface after thorougly
cleaning oil, grease, dirt and foreign matter, cost of materials,
labour complete as per specifications and as per directions of
Engineer-in-charge. | Sqm | 145.95 | 145.95 | 43.2 | False | None | None | False | None | False | 6305.04 | 0 | 3263909 | 113059 | None | Item No 1 | Providing and fixing green board panelled 1mm thick metal
sheet framed with aluminium channel section complete as per IS
standards | No | 8500.0 | 8500.0 | 4.0 | False | None | None | False | None | False | 34000.0 | 0 | 3263910 | 113059 | None | PWD SR-2023-24, Vol. 2 P. No. 84, Item No. 11.26. | Providing and fixing hand rail of approved size by welding etc.
to steel ladder railing, balcony railing, staircase railing and
similar works, including applying priming coat of approved
steel primer. M.S. tube including cost of materials, labour, usage
charges of machinery complete as per specifications and as per
directions of the Engineerin-Charge | Kg | 144.9 | 144.9 | 163.8 | False | None | None | False | None | False | 23734.62 | 0 |
| 1718079599000 | 0 | None | None | Buildings | Electrification work | 112838.4 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3263911 | 113060 | None | PWD Electrical SR 23-24, P. No. 2 It. No. 1.2.1 | Concealed couduit Supplying heavy gauge PVC conduit pipe
……mm dia .mm thick confirming to IS 2509 with suitable
size bends, metal/PVC junction boxes, adhesive paste etc., and
running before concreting the slab. The conduit should be tied
to the reinforcement rods by using binding wires and unused
ways of junction boxes and pipe ends should be covered using
PVC end enclosures, run with 18SWG GI fish wire wherever
necessary19/20mm dia 2mm | Rmtr | 66.0 | 66.0 | 120.0 | False | None | None | False | None | False | 7920.0 | 0 | 3263912 | 113060 | None | PWD Electrical SR 23-24, P. No. 2 It. No. 1.3.1 | Supplying heavy gauge PVC Conduit Pipe ….dia .mm
thick with suitable size bends, metal junction boxes adhesive
paste etc., by groove cutting in the wall and fixing by bracing U
or J hooks and cement plastering up to the wall surface
and run with 18 SWG GI fish wire run throughout the conduit
wherever necessary | Rmtr | 68.0 | 68.0 | 80.0 | False | None | None | False | None | False | 5440.0 | 0 | 3263913 | 113060 | None | PWD Electrical SR 23-24, P. No. 5 It. No. 2.3.3 | Wiring for lighting/power circuit using one of FRLS PVC
insulated 1100V grade, multistrand copper wire with low
conductor resistance single core in open or concealed
system of wiring with specified IS-694:confirming to latest
amendments 2.5 Sqmm | Mtr | 42.0 | 42.0 | 250.0 | False | None | None | False | None | False | 10500.0 | 0 | 3263914 | 113060 | None | PWD Electrical SR 23-24, P. No. 5 It. No. 2.3.4 | Wiring for lighting/power circuit using one of FRLS PVC
insulated 1100V grade, multistrand copper wire with low
conductor resistance single core in open or concealed
system of wiring with specified IS-694:confirming to latest
amendments. 4 Sqmm | Mtr | 63.0 | 63.0 | 120.0 | False | None | None | False | None | False | 7560.0 | 0 | 3263915 | 113060 | None | PWD Electrical SR 23-24, P. No. 8 It. No. 3.4.3 | Supplying and flush mounting powder coated / galvanized
metal box suitable for mounting modular switch plates. The box
should be firmly flush mounted after due groove cutting in
Brick/Stone/C.C wall 4 - 5 way | No | 177.0 | 177.0 | 5.0 | False | None | None | False | None | False | 885.0 | 0 | 3263916 | 113060 | None | PWD Electrical SR 23-24, P. No. 8 It. No. 3.5.3 | Supplying andfixing superior quality modular switch mounting
polycarbonate plate with necessary supporting back plate with
required nos. of machine screws, bolts nuts etc.,complete on the
existing metal/PVC box. 4 Module | No | 175.0 | 175.0 | 5.0 | False | None | None | False | None | False | 875.0 | 0 | 3263917 | 113060 | None | PWD Electrical SR 23-24, P. No. 9 It. No. 3.6.1 | Supplying and fixing of modular switch & connected accessories
on existing modular switch plate as per IS 3854
and IS 1293 | No | 102.0 | 102.0 | 30.0 | False | None | None | False | None | False | 3060.0 | 0 | 3263918 | 113060 | None | PWD Electrical SR 23-24, P. No. 9 It. No. 3.6.3 | Supplying and fixing of modular switch & connected accessories
on existing modular switch plate as per IS 3854
and IS 1293.6Amps 3way socket | No | 171.0 | 171.0 | 4.0 | False | None | None | False | None | False | 684.0 | 0 | 3263919 | 113060 | None | PWD Electrical SR 23-24, P. No. 9 It. No. 3.6.4 | Supplying and fixing of modular switch & connected accessories
on existing modular switch plate as per IS 3854
and IS 1293 Stepped Regulator | No | 357.0 | 357.0 | 8.0 | False | None | None | False | None | False | 2856.0 | 0 | 3263920 | 113060 | None | PWD Electrical SR 23-24, P. No. 17 It. No. 5.18.1 | Supplying and fixing miniature circuit breakers on existing MCB
distribution boards using necessary fixing materials
and 'C' Type curve, indicator ON/OFF, energy cross-3 with
Short circuit breaking capacity of 10K and complete wiring as
required confirming to IEC 60898. 6-32Amps SP | No | 415.0 | 415.0 | 5.0 | False | None | None | False | None | False | 2075.0 | 0 | 3263921 | 113060 | None | PWD Electrical SR 23-24, P. No. 17 It. No. 5.18.8 | Supplying and fixing miniature circuit breakers on existing MCB
distribution boards using necessary fixing materials and 'C'
Type curve, indicator ON/OFF, energy cross-3 with Short
circuit breaking capacity of 10K and complete wiring as required
confirming to IEC 60898. 40 Amps TPN | No | 3044.0 | 3044.0 | 2.0 | False | None | None | False | None | False | 6088.0 | 0 | 3263922 | 113060 | None | PWD Electrical SR 23-24, P. No. 28 It. No. 5.19.7 | Supplying and fixing regular MCB distribution boards on wall /
wood board / flush mounting using required clamps, bolts, nuts
etc., with provision for fixing suitable type capacity MCB's
single phase / 3 phase / single door with powder coated
painting. Made out of 14 SWG MS enclosure 6 Way SP & N | No | 1791.0 | 1791.0 | 2.0 | False | None | None | False | None | False | 3582.0 | 0 | 3263923 | 113060 | None | PWD Electrical SR 23-24, P. No. 20 It. No. 5.41.2 | Supplying and fixing angle iron frame work fabricated out of
M.S. angle iron. and M.S. flat … with bolts, washers etc., and
painted with 2 coats of red oxide and then two coats of
approved paint. 50x50x6mm | Rmtr | 395.0 | 395.0 | 8.0 | False | None | None | False | None | False | 3160.0 | 0 | 3263924 | 113060 | None | PWD Electrical SR 23-24, P. No. 20 It. No. 5.42.2 | Fabricating supplying and mounting MS box made out …
SWG suitable for floor / wall mounting, fully weather proof
with provision for better heat dissipation, provided with hinged
front cover, equipped with tamper proof locking arrangements,
with suitable size clamps | Sq CM | 0.43 | 0.43 | 6800.0 | False | None | None | False | None | False | 2924.0 | 0 | 3263925 | 113060 | None | PWD Electrical SR 23-24, P. No. 55 It. No. 12.60. | Supplying & Fixing Chemical earthling for grounding.
Conduits, IC cut-outs& otherequipments backfill compound
which is non- corrosive, thermally conductive, potential to
permissible limits, superior Fault conduction capacity,
nontoxic,weathe resistance & capable of achieving ohmic value | Kit | 4528.0 | 4528.0 | 1.0 | False | None | None | False | None | False | 4528.0 | 0 | 3263926 | 113060 | None | PWD Electrical SR 23-24, P. No. 41 It. No. 6.6.2 | Digging of trench of 0.60m deep x 0.50mtrs wide refilling the
trench to the required ground level and consolidating etc.,
complete | Mtr | 102.0 | 102.0 | 5.0 | False | None | None | False | None | False | 510.0 | 0 | 3263927 | 113060 | None | PWD Electrical SR 23-24, P. No. 40 It. No. 6.4.4 | Supplying of 1.1 KV LT UG cable XLPE or Heat resistant
PVC insulated, PVC extruded Inner sheath armoured UG LT
cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip
thickness in average +5% and resistivity 14 Ohms/Kms (Max) as
per IS-3975 | Rmtr | 150.0 | 150.0 | 10.0 | False | None | None | False | None | False | 1500.0 | 0 | 3263928 | 113060 | None | PWD Electrical SR 23-24, P. No. 41 It. No. 6.5.1 | Labour charges for laying of 1.1KV class UG cable when
supplied agency in existing trench GI pipe/stonewere pipe/on
wall/on pole as required exising trench/duct
6 to 16 Sqmm | Mtr | 11.88 | 11.88 | 5.0 | False | None | None | False | None | False | 59.4 | 0 | 3263929 | 113060 | None | PWD Electrical SR 23-24, P. No. 30 It. No. 6.3.1 | Supplying capacitor type ceiling fan complete with down rod
blades, snackles, canopies etc., for operation on 230 volts, 50
cycles. Single phase AC supply confirming to IS-374-1979 and
with double ball bearing system. 48" sweep (1200mm) regular
model | No | 2984.0 | 2984.0 | 8.0 | False | None | None | False | None | False | 23872.0 | 0 | 3263930 | 113060 | None | PWD Electrical SR 23-24, P. No. 57 It. No. 13.11 | Fixing a ceiling / wall mounting fan of all capacities and all
types, with necessary clamps and 'S' hook made out of 15mm
dia MS rod, with 5 amps. ceiling rose of approved quality with
necessary length of 23 / 0.0076 inch PVC insulated twin twisted
wire of approved quality, mounted on a suitable size wooden | No | 315.0 | 315.0 | 8.0 | False | None | None | False | None | False | 2520.0 | 0 | 3263931 | 113060 | None | PWD Electrical SR 23-24, P. No. 64 It. No. 11.3.2 | Supplying of .feet - PVC Batten with integrated LED
tube.W with high quality diffuser with Life of 25000 burning
hours & 70% lumen maintenance with CRI 80. Power Input:
220-240V @ 50/60Hz & Power factor 0.9 along with CE
approved. 2 years Warranty against any manufacturing defect
working under standard electrical condition | No | 690.0 | 690.0 | 20.0 | False | None | None | False | None | False | 13800.0 | 0 | 3263932 | 113060 | None | PWD Electrical SR 23-24, P. No. 56 It. No. 13.7 | Fixing all types and all capacities flourescent/false ceiling/spot
light/CFL fittings indoor on the wall/ceiling/rafters/girders
using 23/0.0076" twin twisted PVC insulated wires, required
nos. of round blcks and clamps (if required) on
wall/ceiling/rafters/girders. on wall/ceiling | No | 122.0 | 122.0 | 20.0 | False | None | None | False | None | False | 2440.0 | 0 | 3263933 | 113060 | None | Item No 1 | KKRDB Logo Board | No | 6000.0 | 6000.0 | 1.0 | False | None | None | False | None | False | 6000.0 | 0 |
|
|
---|