1718698452000 | 0 | None | None | Buildings | Construction of Sri D.Devaraj Aras Post Metric Girls Hostel Building 2nd Phase at Laila, Belathangadi Taluk, Dakshina Kannada District | 13145019.96 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3301279 | 115080 | None | code01 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)--M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. sl.no-2.5.2, pg.no-17, volume-I. SECOND FLOOR. COLUMN. | Cum | 13289.65 | 13289.65 | 14.75 | False | None | None | False | None | False | 196022.3375 | 0 | 3301280 | 115080 | None | code02 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)--M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. sl.no-2.5.2, pg.no-17, volume-I. TERRACE FLOOR. COLUMN. | Cum | 13419.94 | 13419.94 | 7.84 | False | None | None | False | None | False | 105212.3296 | 0 | 3301281 | 115080 | None | code03 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)-- Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates. Page 15, Sl. No.2.1.4, Volume-I, DUMMY COLUMN, TERRACE FLOOR. | Cum | 12192.28 | 12192.28 | 0.95 | False | None | None | False | None | False | 11582.666 | 0 | 3301282 | 115080 | None | code04 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)--M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates sl.no-2.5.2, pg.no-17, volume-I. BEAM, SECOND FLOOR. | Cum | 12507.91 | 12507.91 | 21.55 | False | None | None | False | None | False | 269545.4605 | 0 | 3301283 | 115080 | None | code05 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)--M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates sl.no-2.5.2, pg.no-17, volume-I. BEAM, TERRACE FLOOR. | Cum | 12630.54 | 12630.54 | 13.68 | False | None | None | False | None | False | 172785.7872 | 0 | 3301284 | 115080 | None | code06 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)--M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. sl.no-2.5.2, pg.no-17, volume-I. LINTEL, SECOND FLOOR. | Cum | 12507.91 | 12507.91 | 6.44 | False | None | None | False | None | False | 80550.9404 | 0 | 3301285 | 115080 | None | code07 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)-- Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates. Page 15, Sl. No.2.1.4, Volume-I,CILL, SECOND FLOOR. | Cum | 11363.68 | 11363.68 | 1.87 | False | None | None | False | None | False | 21250.0816 | 0 | 3301286 | 115080 | None | code08 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)--M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. sl.no-2.5.2, pg.no-17, volume-I. SAIRCASE, SECOND FLOOR. | Cum | 11726.16 | 11726.16 | 3.65 | False | None | None | False | None | False | 42800.484 | 0 | 3301287 | 115080 | None | code09 | Providing and constructing laterite size stone masonry including cost and conveyance of all materials curing etc complete as per specification I.S. 3620/1979 having compressive strength not less than 3.5 N/mm2 for saturated dry samples - For Super structure in CM 1:6. SL.NO-5.7,PG.NO-9, volume-2, SECOND FLOOR. | Cum | 7716.91 | 7716.91 | 63.45 | False | None | None | False | None | False | 489637.9395 | 0 | 3301288 | 115080 | None | code10 | Providing and constructing laterite size stone masonry including cost and conveyance of all materials curing etc complete as per specification I.S. 3620/1979 having compressive strength not less than 3.5 N/mm2 for saturated dry samples - For Super structure in CM 1:6. SL.NO-5.7,PG.NO-9, volume-2, TERRACE FLOOR. | Cum | 7792.57 | 7792.57 | 12.53 | False | None | None | False | None | False | 97640.9021 | 0 | 3301289 | 115080 | None | code11 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.-Sl No.6.32, PageNo.17 Volume-II, SECOND FLOOR. | Sqm | 1496.54 | 1496.54 | 204.82 | False | None | None | False | None | False | 306521.3228 | 0 | 3301290 | 115080 | None | code12 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. S.No. 6.33, Page No.17, Volume-2. SECOND FLOOR. | Sqm | 1406.29 | 1406.29 | 73.9 | False | None | None | False | None | False | 103924.831 | 0 | 3301291 | 115080 | None | code13 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. S.No. 6.33, Page No.17, Volume-2. TERRACE FLOOR. | Sqm | 1420.08 | 1420.08 | 124.5 | False | None | None | False | None | False | 176799.96 | 0 | 3301292 | 115080 | None | code14 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.sl.no-6.34, pg.no-17, volume-2.SECOND FLOOR. | Sqm | 1261.21 | 1261.21 | 1.8 | False | None | None | False | None | False | 2270.178 | 0 | 3301293 | 115080 | None | code15 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)--M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. sl.no-2.5.2, pg.no-17, volume-I. SLAB, SECOND LOOR. | Cum | 11726.16 | 11726.16 | 54.96 | False | None | None | False | None | False | 644469.7536 | 0 | 3301294 | 115080 | None | code16 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)--M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. sl.no-2.5.2, pg.no-17, volume-I. SLAB, TERRACE LOOR. | Cum | 11841.13 | 11841.13 | 24.32 | False | None | None | False | None | False | 287976.2816 | 0 | 3301295 | 115080 | None | code17 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)--M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. sl.no-2.5.2, pg.no-17, volume-I. CHAJJA, SECOND FLOOR. | Cum | 11335.29 | 11335.29 | 3.78 | False | None | None | False | None | False | 42847.3962 | 0 | 3301296 | 115080 | None | code18 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. a)Buildings-Sl. No.2.11 , Page No.18 Volume-I, SECOND FLOOR. | Tonne | 102195.68 | 102195.68 | 14.77 | False | None | None | False | None | False | 1509430.1936 | 0 | 3301297 | 115080 | None | code19 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. a)Buildings-Sl. No.2.11 , Page No.18 Volume-I, TERRACE FLOOR. | Tonne | 103197.6 | 103197.6 | 6.71 | False | None | None | False | None | False | 692455.896 | 0 | 3301298 | 115080 | None | code20 | Providing Red Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. Sl.No 12.13.2, Page No.100,Volume- 2. SECOND FLOOR. | Cum | 113783.04 | 113783.04 | 0.69 | False | None | None | False | None | False | 78510.2976 | 0 | 3301299 | 115080 | None | code21 | Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross- section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminate shall be moulded with fire
resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all
sides. M.S. stay shall be provided at the bottom to steady the frame. sl.no-12.96, pg.no-112,volume 2. SECOND FLOOR. | m | 734.56 | 734.56 | 76.2 | False | None | None | False | None | False | 55973.472 | 0 | 3301300 | 115080 | None | code22 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made). Sl. No.12.90, Page No. 110, Volume-2. SECOND FLOOR. | Sqm | 7692.92 | 7692.92 | 33.0 | False | None | None | False | None | False | 253866.36 | 0 | 3301301 | 115080 | None | code23 | Providing & fixing of 2.5 track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and
lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 94mm width x 45mm height with reinforcement of 1mm thickness and Sash with overall size of 39mm x 58mm with GI reinforcement of 1.5mm and mesh sash of size 25mm x 42mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 5mm plain float glass, standard hardware& single
point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 1819mm x 1819mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall
not be made)SL.NO-12.89, PG.NO-110, VOLUME-2. SECOND FLOOR. | Sqm | 7483.86 | 7483.86 | 13.5 | False | None | None | False | None | False | 101032.11 | 0 | 3301302 | 115080 | None | code24 | Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)- SL.NO-12.85, PG.NO-109, VOLUME-2. SECOND FLOOR. | Sqm | 6533.39 | 6533.39 | 17.1 | False | None | None | False | None | False | 111720.969 | 0 | 3301303 | 115080 | None | code25 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification.-35 mm thick both side commercial, Sl. No. 12.57.6,Page No. 105, Volume-2. SECOND FLOOR. | Sqm | 3795.05 | 3795.05 | 22.54 | False | None | None | False | None | False | 85540.427 | 0 | 3301304 | 115080 | None | code26 | Providing and fixing to existing door frames Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames.- 30 mm thickness-Sl. No. 12.97.1,Page No. 112, Volume-2. SECOND FLOOR. | Sqm | 3660.25 | 3660.25 | 22.05 | False | None | None | False | None | False | 80708.5125 | 0 | 3301305 | 115080 | None | code27 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. sl.no-12.51, pg.no-104, volume-2. SECOND FLOOR. | Nos. | 1160.68 | 1160.68 | 21.0 | False | None | None | False | None | False | 24374.28 | 0 | 3301306 | 115080 | None | code28 | Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. SL.NO-12.58, PG.NO-105,VOLUME-2. | Nos | 134.4 | 134.4 | 9.0 | False | None | None | False | None | False | 1209.6 | 0 | 3301307 | 115080 | None | code29 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. SL.NO-12.60, PG.NO-105,VOLUME-2. | Nos. | 1178.24 | 1178.24 | 42.0 | False | None | None | False | None | False | 49486.08 | 0 | 3301308 | 115080 | None | code30 | Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. complete SL.NO-12.62, PG.NO-105,VOLUME-2. | Nos. | 265.44 | 265.44 | 42.0 | False | None | None | False | None | False | 11148.48 | 0 | 3301309 | 115080 | None | code31 | Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete : 250x10mm, SL.NO-12.76.1, PG.NO-107,VOLUME-2. | Each | 487.2 | 487.2 | 42.0 | False | None | None | False | None | False | 20462.4 | 0 | 3301310 | 115080 | None | code32 | Providing and fixing bright finished brass butt hinges with necessary screws etc. complete :, 125x85x5.5mm.(heavy type) Sl.no-12.75.1, pg.no-107,volume-2. | Nos. | 308.0 | 308.0 | 36.0 | False | None | None | False | None | False | 11088.0 | 0 | 3301311 | 115080 | None | code33 | Providing and fixing bright finished brass butt hinges with necessary screws etc. complete :, 100x85x5.5mm.(heavy type) Sl.no-12.75.3, pg.no-107,volume-2. | Nos. | 229.6 | 229.6 | 36.0 | False | None | None | False | None | False | 8265.6 | 0 | 3301312 | 115080 | None | code34 | Providing and fixing MS Hold fasts (SL. No 285,Page No.A-21, Basic Rate Rs. 32.00), volume-2. | Each | 35.84 | 35.84 | 126.0 | False | None | None | False | None | False | 4515.84 | 0 | 3301313 | 115080 | None | code35 | Providing and fixing PTMT door catcher of length 72 mm and dia. of 42 mm with suitable washers weighing not less than 33 gms. Sl.no-12.64, pg.no-105.volume-2. | Nos | 61.6 | 61.6 | 9.0 | False | None | None | False | None | False | 554.4 | 0 | 3301314 | 115080 | None | code36 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding, Sl. No. 11.34A, Page No. 85,Volume-2.SECOND FLOOR. | Kgs | 191.92 | 191.92 | 1144.8 | False | None | None | False | None | False | 219710.016 | 0 | 3301315 | 115080 | None | code37 | Providing and fixing 1 mm thick M.S. sheet sliding-shutters, with frame and diagonal braces of 40x40x6 mm angle iron, 3 mm M.S. gusset plates at the junctions and corners, 25 mm dia pulley, 40x40x6 mm angle and T- iron guide at the top and bottom respectively, including applying a
priming coat of approved steel primer including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. Sl. No. 11.4, Page No. 77, Volume-2. TERRACE FLOOR. | Sqm | 6022.95 | 6022.95 | 3.0 | False | None | None | False | None | False | 18068.85 | 0 | 3301316 | 115080 | None | code38 | Providing 12 mm cement plaster with Cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer in-charge.. Sl. No. 8.6.1, Page No. 42, Volume-2. CEILING, SECOND FLOOR. | Sqm | 369.0 | 369.0 | 400.13 | False | None | None | False | None | False | 147647.97 | 0 | 3301317 | 115080 | None | code39 | Providing 12 mm cement plaster with Cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer in-charge.. Sl. No. 8.6.1, Page No. 42, Volume-2. CEILING, TERRACE FLOOR. | Sqm | 372.61 | 372.61 | 99.7495 | False | None | None | False | None | False | 37167.661195 | 0 | 3301318 | 115080 | None | code40 | Providing 15 mm cement plaster with cement mortar 1:3 (1 cement:
3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sl.No 8.7, Page No.42, Volume-2. INTERNAL WALL, SECOND FLOOR. | Sqm | 418.12 | 418.12 | 704.81 | False | None | None | False | None | False | 294695.1572 | 0 | 3301319 | 115080 | None | code41 | Providing 15 mm cement plaster with cement mortar 1:3 (1 cement:
3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sl.No 8.7, Page No.42, Volume-2. INTERNAL WALL, TERRACE FLOOR. | Sqm | 422.22 | 422.22 | 66.7 | False | None | None | False | None | False | 28162.074 | 0 | 3301320 | 115080 | None | code42 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sl.No. 8.2.1, Page No.41, Volume- 2. SEOND FLOOR. | Sqm | 337.01 | 337.01 | 284.66 | False | None | None | False | None | False | 95933.2666 | 0 | 3301321 | 115080 | None | code43 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sl. No. 8.9, Page No.42, Volume-2. EXTERNAL WALL, SECOND FLOOR. | Sqm | 439.82 | 439.82 | 450.36 | False | None | None | False | None | False | 198077.3352 | 0 | 3301322 | 115080 | None | code44 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sl. No. 8.9, Page No.42, Volume-2. EXTERNAL WALL, TERRACE FLOOR. | Sqm | 444.14 | 444.14 | 853.18 | False | None | None | False | None | False | 378931.3652 | 0 | 3301323 | 115080 | None | code45 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)-- Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates. Page 15, Sl. No.2.1.4, Volume-I, SECOND FLOOR. | Cum | 7102.3 | 7102.3 | 14.25 | False | None | None | False | None | False | 101207.775 | 0 | 3301324 | 115080 | None | code46 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)-- Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates. Page 15, Sl. No.2.1.4, Volume-I, TERRACE FLOOR. | Cum | 7171.93 | 7171.93 | 0.83 | False | None | None | False | None | False | 5952.7019 | 0 | 3301325 | 115080 | None | code47 | Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications. Sl.No 7.18, Page No.23, Volume-2. SECOND FLOOR. | Cum | 2304.22 | 2304.22 | 9.61 | False | None | None | False | None | False | 22143.5542 | 0 | 3301326 | 115080 | None | code48 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the
Engineer-in-Charge. ** Polished Granite stone slab Black, Cat Eye, River Pink or equivalent. Sl.No 9.24, Page No.63
Volume-II, SECOND FLOOR. | Sqm | 3258.12 | 3258.12 | 63.8 | False | None | None | False | None | False | 207868.056 | 0 | 3301327 | 115080 | None | code49 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the
Engineer-in-Charge. ** Polished Granite stone slab Black, Cat Eye, River Pink or equivalent. Sl.No 9.24, Page No.63
Volume-II, TERRACE FLOOR. | Sqm | 3290.07 | 3290.07 | 15.48 | False | None | None | False | None | False | 50930.2836 | 0 | 3301328 | 115080 | None | code50 | Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications.. sl.no-9.30, pg.no-64,volume-2. SECOND FLOOR. | Sqm | 6086.71 | 6086.71 | 23.7 | False | None | None | False | None | False | 144255.027 | 0 | 3301329 | 115080 | None | code51 | Providing and laying vitrified floor tiles with thickness 9-10 mm in
different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm sl.no-9.12.2, pg.no-60.volume-2. SECOND FLOOR. | Sqm | 1308.05 | 1308.05 | 248.5 | False | None | None | False | None | False | 325050.425 | 0 | 3301330 | 115080 | None | code52 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete.. Sl.No 9.11, Page No.60, Volume-2, SECOND FLOOR. | Sqm | 1015.59 | 1015.59 | 51.15 | False | None | None | False | None | False | 51947.4285 | 0 | 3301331 | 115080 | None | code53 | Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg/m2, including pointing in white cement mixed with pigment of matching shade complete.. Sl.No 10.14, Page No.71, Volume-2. SECOND FLOOR. | Sqm | 1263.49 | 1263.49 | 284.66 | False | None | None | False | None | False | 359665.0634 | 0 | 3301332 | 115080 | None | code54 | Providing flooring with 25mm thick polished Cuddapah slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab , including cost of materials, labour, curing, polishing complete as per specifications. Sl.No 9.36, Page No.64, Volume-2. SECOND FLOOR. | Sqm | 1884.96 | 1884.96 | 2.1 | False | None | None | False | None | False | 3958.416 | 0 | 3301333 | 115080 | None | code55 | Providing and laying flooring and steps machine cut granite slabs 40 mm thick on cement mortar bed 1:6, 25 mm thick, and pointed with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar labour, curing complete as per specifications.. Sl.No 9.28 Page No.63, Volume-2. SECOND FLOOR. | Sqm | 4888.33 | 4888.33 | 2.49 | False | None | None | False | None | False | 12171.9417 | 0 | 3301334 | 115080 | None | code56 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. Sl.No 8.51, Page No.50, Volume-2. SECOND FLOOR. | Sqm | 114.24 | 114.24 | 1104.93 | False | None | None | False | None | False | 126227.2032 | 0 | 3301335 | 115080 | None | code57 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. Sl.No 8.51, Page No.50, Volume-2. TERRACE FLOOR. | Sqm | 115.36 | 115.36 | 167.02 | False | None | None | False | None | False | 19267.4272 | 0 | 3301336 | 115080 | None | code58 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Specialprimer applied @ 0.75 ltr /10 m² with paint of approved quality to givean even shade, after thoroughly brooming the surface to remove all dirt,dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sl.No 8.33.1, Page No.46, Volume-2. CEILING, SECOND FLOOR. | Sqm | 180.5 | 180.5 | 400.13 | False | None | None | False | None | False | 72223.465 | 0 | 3301337 | 115080 | None | code59 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Specialprimer applied @ 0.75 ltr /10 m² with paint of approved quality to givean even shade, after thoroughly brooming the surface to remove all dirt,dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sl.No 8.33.1, Page No.46, Volume-2. CEILING, TERRACE FLOOR. | Sqm | 182.27 | 182.27 | 100.32 | False | None | None | False | None | False | 18285.3264 | 0 | 3301338 | 115080 | None | code60 | Finishing with Deluxe Multi surface paint system for interiors andexteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Specialprimer applied @ 0.75 ltr /10 m² with paint of approved quality to givean even shade, after thoroughly brooming the surface to remove all dirt,dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sl.No 8.33.1, Page No.46, Volume-2.INTERNAL WALL, SECOND FLOOR. | Sqm | 180.5 | 180.5 | 704.81 | False | None | None | False | None | False | 127218.205 | 0 | 3301339 | 115080 | None | code61 | Finishing with Deluxe Multi surface paint system for interiors andexteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Specialprimer applied @ 0.75 ltr /10 m² with paint of approved quality to givean even shade, after thoroughly brooming the surface to remove all dirt,dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sl.No 8.33.1, Page No.46, Volume-2.INTERNAL WALL, TERRACE FLOOR. | Sqm | 182.27 | 182.27 | 66.7 | False | None | None | False | None | False | 12157.409 | 0 | 3301340 | 115080 | None | code62 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sl.No 8.30, Page No.46, Volume-2. EXTERNAL WALL, SECOND FLOOR. | Sqm | 198.78 | 198.78 | 450.36 | False | None | None | False | None | False | 89522.5608 | 0 | 3301341 | 115080 | None | code63 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sl.No 8.30, Page No.46, Volume-2. EXTERNAL WALL, TERRACE FLOOR. | Sqm | 200.73 | 200.73 | 853.18 | False | None | None | False | None | False | 171258.8214 | 0 | 3301342 | 115080 | None | code64 | Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sl.No 8.29, Page No.45,Volume-2. SECOND FLOOR. | Sqm | 323.3 | 323.3 | 9.01 | False | None | None | False | None | False | 2912.933 | 0 | 3301343 | 115080 | None | code65 | Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sl.No 8.29, Page No.45,Volume-2. TERRACE FLOOR. | Sqm | 326.47 | 326.47 | 17.06 | False | None | None | False | None | False | 5569.5782 | 0 | 3301344 | 115080 | None | code66 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sl.No 8.41,Page No.48, Volume-2. SECOND FLOOR. | Sqm | 190.78 | 190.78 | 63.6 | False | None | None | False | None | False | 12133.608 | 0 | 3301345 | 115080 | None | code67 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/ litre as per specifications and as per directions of Engineer in charge.Sl.No 8.55.1, Page No.51, Volume-2. SECOND FLOOR. | Sqm | 63.97 | 63.97 | 58.6 | False | None | None | False | None | False | 3748.642 | 0 | 3301346 | 115080 | None | code68 | Polishing on wood work with ready mixed wax polish of approved brand and manufacture : New work to give an even surface including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.sl.no-8.47, pg.no-49. SECOND FLOOR. | Sqm | 154.22 | 154.22 | 58.6 | False | None | None | False | None | False | 9037.292 | 0 | 3301347 | 115080 | None | code69 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist
slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge..Sl.No 11.28, Page No.83, Volume-2. SECOND FLOOR. | Kg | 645.46 | 645.46 | 84.0 | False | None | None | False | None | False | 54218.64 | 0 | 3301348 | 115080 | None | code70 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 100 mm diameter. SL.NO-13.48, PG.NO-125, VOLUME-2. | m | 332.44 | 332.44 | 110.4 | False | None | None | False | None | False | 36701.376 | 0 | 3301349 | 115080 | None | code71 | Providing and fixing of Laterite cladding tiles of size 230x75x10mm thick on 12mm thick cement mortar 1:3 (1 cement : 3 coarse sand) & jointed with Adhesive over rough plaster surface excluding cost of rough plastered surface. The work includes cost of all materials, labour charges for all items of work, usage charges for equipment, etc., complete as per specification. SL.NO-10.21, PG.NO-72, VOLUME-2. SECOND FLOOR. | Sqm | 2488.15 | 2488.15 | 48.3 | False | None | None | False | None | False | 120177.645 | 0 | 3301350 | 115080 | None | code72 | Providing and laying 60mm thick factory made cement concrete paver block of approved shape and colour of M -30 grade made of C&D waste by block making machine with vibratory compaction laid in required
pattern and including over 50mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge. SL.NO-9.25, PG.NO-63, VOLUME-2. | Sqm | 896.0 | 896.0 | 45.0 | False | None | None | False | None | False | 40320.0 | 0 | 3301351 | 115080 | None | code73 | Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in Granite, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete.SL.NO-10.4, PG.NO-69, VOLUME-2. | m | 675.16 | 675.16 | 5.6 | False | None | None | False | None | False | 3780.896 | 0 | 3301352 | 115080 | None | code74 | Providing and fixing Steel work in built up tubular (round, square or
rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. Sl.No 11.16.2, Page No.82, Volume-2. TERRACE FLOOR. | Kg | 169.58 | 169.58 | 5550.72 | False | None | None | False | None | False | 941291.0976 | 0 | 3301353 | 115080 | None | code75 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05 %) total coated thickness with zinc coating 120 g/m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineerin-
charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. Sl.No 7.38, Page No.26, Volume-2. TERRACE FLOOR. | Sqm | 655.24 | 655.24 | 396.48 | False | None | None | False | None | False | 259789.5552 | 0 | 3301354 | 115080 | None | code76 | Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 g/m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete :. Crimp curve, Sl.No 7.39.5, Page No.27 Volume-2. | Sqm | 490.28 | 490.28 | 25.5 | False | None | None | False | None | False | 12502.14 | 0 | 3301355 | 115080 | None | code77 | Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 g/m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete :. Ridges plain (500 - 600mm) , Sl.No 7.39.1, Page No.26
Volume-II | m | 520.27 | 520.27 | 80.0 | False | None | None | False | None | False | 41621.6 | 0 | 3301356 | 115080 | None | code78 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)-- Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates. Page 15, Sl. No.2.1.4, Volume-I, TERRACE FLOOR. | Cum | 7171.93 | 7171.93 | 37.75 | False | None | None | False | None | False | 270740.3575 | 0 | 3301357 | 115080 | None | code79 | Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6 kg/m2 to achieve final DFT (Dry Film Thickness) of 1mm including prime coat of epoxy primer @150 g/m2 and protection with 120gsm Geo-textile over the waterproofing
membrane. The finished cost to include surface preparation,
making coving at Junction, Bore Packing, treatment of construction joints completely as per specification.. sl.no-15.1, pg.no-149. volume-2. TERRACE FLOOR. | Sqm | 942.49 | 942.49 | 61.97 | False | None | None | False | None | False | 58406.1053 | 0 | 3301358 | 115080 | None | code80 | Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sl.No 8.7, Page No.42, Volume-2. TERRACE FLOOR. | Sqm | 422.22 | 422.22 | 377.6 | False | None | None | False | None | False | 159430.272 | 0 | 3301359 | 115080 | None | code81 | Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove. Page 54, Sl. No.8.79, Volume-2, TERRACE FLOOR. | m | 59.99 | 59.99 | 370.0 | False | None | None | False | None | False | 22196.3 | 0 | 3301360 | 115080 | None | code82 | PLUMBING AND SANITARY: Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever
required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests, Sl.No 14.1.1, Page No.131, Volume-II | Nos | 5470.08 | 5470.08 | 1.0 | False | None | None | False | None | False | 5470.08 | 0 | 3301361 | 115080 | None | code83 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito
proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid. Sl.No 14.3.1, Page No.131,, Volume-II | Nos | 6694.24 | 6694.24 | 5.0 | False | None | None | False | None | False | 33471.2 | 0 | 3301362 | 115080 | None | code84 | Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required: using White Vitreous China Wash basin size 550x400 mm with
a 15 mm CP Brass single hole basin mixer. Sl.No 14.7A, Page No.133, Volume-II | Nos | 4615.52 | 4615.52 | 5.0 | False | None | None | False | None | False | 23077.6 | 0 | 3301363 | 115080 | None | code85 | Providing and fixing 100 mm sand cast Iron grating for gully trap. Sl.No 14.29, Page No.136, Volume-II | Nos | 52.64 | 52.64 | 14.0 | False | None | None | False | None | False | 736.96 | 0 | 3301364 | 115080 | None | code86 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. Sl.No 13.15
Page No.119, Volume-II | Nos | 812.0 | 812.0 | 30.0 | False | None | None | False | None | False | 24360.0 | 0 | 3301365 | 115080 | None | code87 | Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 g. Sl.No 13.13, Page No.119, Volume-II | Nos | 947.52 | 947.52 | 30.0 | False | None | None | False | None | False | 28425.6 | 0 | 3301366 | 115080 | None | code88 | Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end); 25 mm nominal bore, Sl.No 13.4.1
Page No.117, Volume-II | Nos | 614.88 | 614.88 | 1.0 | False | None | None | False | None | False | 614.88 | 0 | 3301367 | 115080 | None | code89 | Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end); 32 mm nominal bore. Sl.No 13.4.2
Page No.117, Volume-II | Nos | 669.76 | 669.76 | 1.0 | False | None | None | False | None | False | 669.76 | 0 | 3301368 | 115080 | None | code90 | Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end): 40 mm nominal bore. Sl.No 13.4.3
Page No.117, Volume-II | Nos | 786.24 | 786.24 | 1.0 | False | None | None | False | None | False | 786.24 | 0 | 3301369 | 115080 | None | code91 | Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end); 50 mm nominal bore. Sl.No 13.4.4
Page No.117, Volume-II | Nos | 957.6 | 957.6 | 1.0 | False | None | None | False | None | False | 957.6 | 0 | 3301370 | 115080 | None | code92 | Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end); 65 mm nominal bore. Sl.No 13.4.5
Page No.117, Volume-II | Nos | 1580.32 | 1580.32 | 1.0 | False | None | None | False | None | False | 1580.32 | 0 | 3301371 | 115080 | None | code93 | Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end): 80 mm nominal bore. Sl.No 13.4.6
Page No.117, Volume-II | Nos | 2326.24 | 2326.24 | 1.0 | False | None | None | False | None | False | 2326.24 | 0 | 3301372 | 115080 | None | code94 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. Sl.No 14.31, Page No.136, Volume-II | Nos | 1366.4 | 1366.4 | 4.0 | False | None | None | False | None | False | 5465.6 | 0 | 3301373 | 115080 | None | code95 | 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g. Sl.No 14.40.2, Page No.137, Volume-II | Nos | 555.52 | 555.52 | 14.0 | False | None | None | False | None | False | 7777.28 | 0 | 3301374 | 115080 | None | code96 | Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : (150mm diameter) SL.NO-13.9.2, PG.NO-118.VOLUME-2. | Nos | 312.48 | 312.48 | 6.0 | False | None | None | False | None | False | 1874.88 | 0 | 3301375 | 115080 | None | code97 | Providing and fixing CP Brass 15 mm nominal dia Single lever telephonic wall mixer of quality & make as approved by Engineer in charge.. Sl.no-14.22B,pg.no-135, volume-2. | Each | 6229.44 | 6229.44 | 6.0 | False | None | None | False | None | False | 37376.64 | 0 | 3301376 | 115080 | None | code98 | Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for:-PVC pipes 160mm dia., 6 kg/sqcm & class 3, Sl.No 1.9-M0I0I, Page No.134, BWSSB | m | 670.88 | 670.88 | 5.0 | False | None | None | False | None | False | 3354.4 | 0 | 3301377 | 115080 | None | code99 | Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for:-PVC pipes 110mm dia., 6 kg/sqcm & class 3- Sl.No 1.7-M0I0G, Page No.134, BWSSB | m | 441.28 | 441.28 | 25.0 | False | None | None | False | None | False | 11032.0 | 0 | 3301378 | 115080 | None | code100 | Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for:-PVC pipes 90mm dia., 6 kg/sqcm & class 3 . Sl.No 1.6- M010F, Page No.134, BWSSB | m | 314.72 | 314.72 | 20.0 | False | None | None | False | None | False | 6294.4 | 0 | 3301379 | 115080 | None | code101 | Providing and fixing Chorinated Poly Venly Cloride (CPVC) pipes conforming to IS15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr. spacing. This includes jointing of pipes and fitting with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete. (concealed work including cutting chases and good the walls etc), For 50 mm dia, Sl.No 13.31.6, VOL-2- | m | 874.72 | 874.72 | 25.0 | False | None | None | False | None | False | 21868.0 | 0 | 3301380 | 115080 | None | code102 | Providing and fixing Chorinated Poly Venly Cloride (CPVC) pipes conforming to IS15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr. spacing. This includes jointing of pipes and fitting with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete. (concealed work including cutting chases and good the walls etc), For 32 mm dia, Sl.No 13.32.4, VOL-2. | m | 623.84 | 623.84 | 68.0 | False | None | None | False | None | False | 42421.12 | 0 | 3301381 | 115080 | None | code103 | Providing and fixing Chorinated Poly Venly Cloride (CPVC) pipes conforming to IS15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr. spacing. This includes jointing of pipes and fitting with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete. (concealed work including cutting chases and good the walls etc), For 25 mm dia, Sl.No 13.32.3, VOL-2 | m | 534.24 | 534.24 | 48.0 | False | None | None | False | None | False | 25643.52 | 0 | 3301382 | 115080 | None | code104 | Providing and fixing Chorinated Poly Venly Cloride (CPVC) pipes conforming to IS15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr. spacing. This includes jointing of pipes and fitting with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete. (concealed work including cutting chases and good the walls etc), For 20 mm dia, Sl.No 13.32.2, VOL-2. | m | 424.48 | 424.48 | 30.0 | False | None | None | False | None | False | 12734.4 | 0 | 3301383 | 115080 | None | code105 | Providing PVC-U INDIVIDUAL U.G.D House service connection (which shall be laid from inside the customer property ) which includes: a) Supply of PVC-U pipe (b) providing and fixing of 315 mm dia the PE Inspection chambres with lid consisting of inlet & outlet arrangements with base, riser of min. 0.42 m depth which includes earth work, fixing in CC-1:2:4 with appurtenances., complete. (c) civil works like Earthwork excavation for the pipeline trenches for laying of PVC-U pipes for the house connections in all types of soils , disintegrated rock,soft rock, hard rock, including cutting of any road using , crossing drains, compound, Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, c.c. wood work, steel work, including T & P and scaffolding wherever necessary sorting the dismantled material, disposal of unserviceable and stacking the serviceable material with all lifts and lead , restoring the damaged portions inside or outside the property premises, refilling the portions of trenches that are dug open including linking to existing sewer network with appurtenances. complete.Supply and fixing of SFRC machinhole cover (Medium Duty) made as per IS to suit existing damaged machinhole cover after removing the debries from inside and outside the existing machinhole etc. with all lead
and lifts. 110 mm dia, INSPECTION CHAMBER (450x450mm), Sl.No 60.1 & 61, Page No.179, BWSSB | Nos | 8761.76 | 8761.76 | 2.0 | False | None | None | False | None | False | 17523.52 | 0 | 3301384 | 115080 | None | code106 | KSRB 13-11 : Providing and placing on terrace, polyethylene water storage tanks as per IS 12701 : 1996 with manhole lid and suitable locking arrangements, making holes of suitable diameter for inlet, outlet and over flow pipes, including cost of all materials, labour, transport charges, HOM and testing complete as per specifications.
Specification No.KBS 13.22, Sl. No. 13.34, vol-2, | Ltr | 10.08 | 10.08 | 4000.0 | False | None | None | False | None | False | 40320.0 | 0 | 3301385 | 115080 | None | code107 | Supplying, installation, testing and commissioning of solar hot water heater comprising of solar Flat Plate Collector (FPC) of size 2120x1040x100mm and stainless steel hot water storage tank with stainless steel heat exchanger absorber made of copper sheet and copper tube of following capacity aluminium box collector with appropriate capacity electrical back up arrangement excluding inlet and out let pipes. SS Model with 100mm thick of 48Kg/M3density Rock wool insulation with 22SWG Aluminium cladding. 200 L. SL.NO-7.3.2. PG.NO-27. CHAPTER-7. | Each | 54297.6 | 54297.6 | 1.0 | False | None | None | False | None | False | 54297.6 | 0 | 3301386 | 115080 | None | code108 | INTERNAL WIRING & POWER POINTS: PVC Conduit and its Accessories; Concealed Conduit System: Supplying heavy gauge PVC conduit pipe … mm dia confirming to IS 2509 with suitable size bends, metal / PVC junction boxes adhesive paste etc. and running before Concreting the Slab. The Conduit should be tied to the reenforcement Rods by using binding wires and the unused ways of Junction boxes should be covered using PVC End enclosures .run with 18 SWG GI finish wire wherever it is necessory: 19/20mm Dia 2mm Thick. SL.NO-1.2.1. | Mtr | 66.0 | 66.0 | 310.0 | False | None | None | False | None | False | 20460.0 | 0 | 3301387 | 115080 | None | code109 | INTERNAL WIRING & POWER POINTS: PVC Conduit and its Accessories; Concealed Conduit System: Supplying heavy gauge PVC conduit pipe … mm dia confirming to IS 2509 with suitable size bends, metal / PVC junction boxes adhesive paste etc. and running before Concreting the Slab. The Conduit should be tied to the reenforcement Rods by using binding wires and the unused ways of Junction boxes should be covered using PVC End enclosures .run with 18 SWG GI finish wire wherever it is necessory: 25mm dia 2mm Thick. SL,NO-1.2.2. | Mtr | 78.0 | 78.0 | 460.0 | False | None | None | False | None | False | 35880.0 | 0 | 3301388 | 115080 | None | code110 | Supplying heavy gauge PVC conduit pipe … mm dia confirming to IS 2509 with suitable size bends, metal / PVC junction boxes adhesive paste etc. by groove cutting in the wall and fixing by bracing U or J hooks and plastering upto wall surface and .run with 18 SWG GI finish wire wherever it is necessory; 19/20mm Dia 2mm Thick, SL.NO-1.3.1. | Mtr | 68.0 | 68.0 | 350.0 | False | None | None | False | None | False | 23800.0 | 0 | 3301389 | 115080 | None | code111 | Supplying heavy gauge PVC conduit pipe … mm dia confirming to IS 2509 with suitable size bends, metal / PVC junction boxes adhesive paste etc. by groove cutting in the wall and fixing by bracing U or J hooks and plastering upto wall surface and .run with 18 SWG GI finish wire wherever it is necessory; 25mm dia 2mm Thick, SL.NO-1.3.2. | Mtr | 79.0 | 79.0 | 400.0 | False | None | None | False | None | False | 31600.0 | 0 | 3301390 | 115080 | None | code112 | Supplying and fixing PVC/ Metal Conduit Deep Junction Boxes; 19/20 mm Deep Junction Box. SL.NO-1.5.1. | Each | 49.0 | 49.0 | 100.0 | False | None | None | False | None | False | 4900.0 | 0 | 3301391 | 115080 | None | code113 | Supplying and fixing PVC/ Metal Conduit Deep Junction Boxes; 25 mm Deep Junction Box.SL.NO-1.5.2. | Each | 56.0 | 56.0 | 50.0 | False | None | None | False | None | False | 2800.0 | 0 | 3301392 | 115080 | None | code114 | Supplying and fixing PVC Casing and capping on the wall or ceiling using materials like bend , screws at an interval 0f 300 mm etc: 20 mm, SL.NO-1.8.1. | Mtr | 28.0 | 28.0 | 50.0 | False | None | None | False | None | False | 1400.0 | 0 | 3301393 | 115080 | None | code115 | Supplying and fixing PVC Casing and capping on the wall or ceiling using materials like bend , screws at an interval 0f 300 mm etc; 25 mm, SL.NO-1.8.2. | Mtr | 35.0 | 35.0 | 40.0 | False | None | None | False | None | False | 1400.0 | 0 | 3301394 | 115080 | None | code116 | Supplying PVC /GI flexible conduit pipe …. Mm dia fixing on surface cover inverted tapared wodden plugs or phill plugs or rawl plugs and clamped using heavy guage saddles in an interval of 300 mm using NF screws and on the eaiter end of the pipe terminated properly: 20 mm, SL.NO-1.9.1. | Mtr | 19.0 | 19.0 | 70.0 | False | None | None | False | None | False | 1330.0 | 0 | 3301395 | 115080 | None | code117 | Supplying PVC /GI flexible conduit pipe …. Mm dia fixing on surface cover inverted tapared wodden plugs or phill plugs or rawl plugs and clamped using heavy guage saddles in an interval of 300 mm using NF screws and on the eaiter end of the pipe terminated properly: 25 mm, SL.NO-1.9.2. | Mtr | 22.0 | 22.0 | 70.0 | False | None | None | False | None | False | 1540.0 | 0 | 3301396 | 115080 | None | code118 | Supply & Fixing of Metal fan box with round Hook, SL.NO-1.13. | Each | 117.0 | 117.0 | 25.0 | False | None | None | False | None | False | 2925.0 | 0 | 3301397 | 115080 | None | code119 | Wires & Cables: Point wiring using copper wire without Switch: Supplying and wiring adopting loop system in existing PVC conduit/casing capping, using copper FRLS PVC insulated multi strand 2 x 1.5 sq.mm copper wire without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/pvc round block complete for each outlet.: Make : KEI / Polycab/ Finolex: Short point upto 3 Mtd. From Tapping point to outlet via switch box. | Point | 269.0 | 269.0 | 60.0 | False | None | None | False | None | False | 16140.0 | 0 | 3301398 | 115080 | None | code120 | Wires & Cables: Point wiring using copper wire without Switch: Supplying and wiring adopting loop system in existing PVC conduit/casing capping, using copper FRLS PVC insulated multi strand 2 x 1.5 sq.mm copper wire without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/pvc round block complete for each outlet.: Make : KEI / Polycab/ Finolex: Medium point above 3 Mts upto 6 Mts. From tapping point to outlet via switch box. SL.NO-2.2.2. | Point | 379.0 | 379.0 | 71.0 | False | None | None | False | None | False | 26909.0 | 0 | 3301399 | 115080 | None | code121 | Wires & Cables: Point wiring using copper wire without Switch: Supplying and wiring adopting loop system in existing PVC conduit/casing capping, using copper FRLS PVC insulated multi strand 2 x 1.5 sq.mm copper wire without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/pvc round block complete for each outlet.: Make : KEI / Polycab/ Finolex; Long point above 6 Mts. Upto 10 Mts. From tapping of point to outlet via switch box. SL.NO-2.2.3. | Point | 555.0 | 555.0 | 20.0 | False | None | None | False | None | False | 11100.0 | 0 | 3301400 | 115080 | None | code122 | Wires & Cables: Point wiring using copper wire without Switch: Supplying and wiring adopting loop system in existing PVC conduit/casing capping, using copper FRLS PVC insulated multi strand 2 x 1.5 sq.mm copper wire without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/pvc round block complete for each outlet.: Make : KEI / Polycab/ Finolex; Two outlet in a row above 3 Mts upto 6 Mts, from tapping point to outlet via switch box. SL.NO-2.1.4. | Point | 677.0 | 677.0 | 2.0 | False | None | None | False | None | False | 1354.0 | 0 | 3301401 | 115080 | None | code123 | Wires & Cables: Point wiring using copper wire without Switch: Supplying and wiring adopting loop system in existing PVC conduit/casing capping, using copper FRLS PVC insulated multi strand 2 x 1.5 sq.mm copper wire without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/pvc round block complete for each outlet.: Make : KEI / Polycab/ Finolex: Three outlet in a row, above 6 Mts. Upto 10 Mts. From tapping point to outlet via switch box. SL.NO-2.1 | Point | 989.0 | 989.0 | 6.0 | False | None | None | False | None | False | 5934.0 | 0 | 3301402 | 115080 | None | code124 | Wiring for Lighting/ Power Circuit using one of PVC insulated 1100V grade, multistrand Copper conductor 1C cable in open or Concealed system of Wiring: 1.5 Sqmm. SL.NO-2.3.2. | Mtr | 26.0 | 26.0 | 2200.0 | False | None | None | False | None | False | 57200.0 | 0 | 3301403 | 115080 | None | code125 | Wiring for Lighting/ Power Circuit using one of PVC insulated 1100V grade, multistrand Copper conductor 1C cable in open or Concealed system of Wiring: 2.5Sqmm. SL.NO-2.3.3. | Mtr | 42.0 | 42.0 | 1800.0 | False | None | None | False | None | False | 75600.0 | 0 | 3301404 | 115080 | None | code126 | Wiring for Lighting/ Power Circuit using one of PVC insulated 1100V grade, multistrand Copper conductor 1C cable in open or Concealed system of Wiring: 4Sqmm, SL.NO-2.3.4. | Mtr | 63.0 | 63.0 | 200.0 | False | None | None | False | None | False | 12600.0 | 0 | 3301405 | 115080 | None | code127 | Wiring for Lighting/ Power Circuit using one of PVC insulated 1100V grade, multistrand Copper conductor 1C cable in open or Concealed system of Wiring; 6 sqmm , SL.NO-2.3.5. | Mtr | 92.0 | 92.0 | 100.0 | False | None | None | False | None | False | 9200.0 | 0 | 3301406 | 115080 | None | code128 | Wiring for Lighting/ Power Circuit using one of PVC insulated 1100V grade, multistrand Copper conductor 1C cable in open or Concealed system of Wiring: 10Sqmm, SL.NO-2.3.6. | Mtr | 167.0 | 167.0 | 80.0 | False | None | None | False | None | False | 13360.0 | 0 | 3301407 | 115080 | None | code129 | Wiring for Lighting/ Power Circuit using one of PVC insulated 1100V grade, multistrand Copper conductor 1C cable in open or Concealed system of Wiring: 16Sqmm, SL.NO-2.3.7. | Mtr | 318.0 | 318.0 | 80.0 | False | None | None | False | None | False | 25440.0 | 0 | 3301408 | 115080 | None | code130 | Switches Sockets and Accessories: Supplying and Flush mounting Powder coated / galvanised metal box suitable for mounting modular switch plates . The Box should be firmly flush mounted after due groove cutting in brick / Stone / C.C wall: Make : Anchor / Schneider / Legrand: 1-2 way , SL.NO-3.4.1. | Each | 138.0 | 138.0 | 24.0 | False | None | None | False | None | False | 3312.0 | 0 | 3301409 | 115080 | None | code131 | Switches Sockets and Accessories: Supplying and Flush mounting Powder coated / galvanised metal box suitable for mounting modular switch plates . The Box should be firmly flush mounted after due groove cutting in brick / Stone / C.C wall: Make : Anchor / Schneider / Legrand; 3 way, SL.NO-3.4.2. | Each | 159.0 | 159.0 | 10.0 | False | None | None | False | None | False | 1590.0 | 0 | 3301410 | 115080 | None | code132 | Switches Sockets and Accessories: Supplying and Flush mounting Powder coated / galvanised metal box suitable for mounting modular switch plates . The Box should be firmly flush mounted after due groove cutting in brick / Stone / C.C wall: Make : Anchor / Schneider / Legrand: 4-5 way, SL.NO-3.4.3. | Each | 177.0 | 177.0 | 35.0 | False | None | None | False | None | False | 6195.0 | 0 | 3301411 | 115080 | None | code133 | Switches Sockets and Accessories: Supplying and Flush mounting Powder coated / galvanised metal box suitable for mounting modular switch plates . The Box should be firmly flush mounted after due groove cutting in brick / Stone / C.C wall: Make : Anchor / Schneider / Legrand: 6 way, SL.NO-3.4.4. | Each | 220.0 | 220.0 | 45.0 | False | None | None | False | None | False | 9900.0 | 0 | 3301412 | 115080 | None | code134 | Switches Sockets and Accessories: Supplying and Flush mounting Powder coated / galvanised metal box suitable for mounting modular switch plates . The Box should be firmly flush mounted after due groove cutting in brick / Stone / C.C wall: Make : Anchor / Schneider / Legrand: 8 way , SL.NO-3.4.5. | Each | 261.0 | 261.0 | 12.0 | False | None | None | False | None | False | 3132.0 | 0 | 3301413 | 115080 | None | code135 | Switches Sockets and Accessories: Supplying and Flush mounting Powder coated / galvanised metal box suitable for mounting modular switch plates . The Box should be firmly flush mounted after due groove cutting in brick / Stone / C.C wall: Make : Anchor / Schneider / Legrand: 12 way, SL.NO-3.4.6. | Each | 319.0 | 319.0 | 10.0 | False | None | None | False | None | False | 3190.0 | 0 | 3301414 | 115080 | None | code136 | Switches Sockets and Accessories: Supplying and Flush mounting Powder coated / galvanised metal box suitable for mounting modular switch plates . The Box should be firmly flush mounted after due groove cutting in brick / Stone / C.C wall: Make : Anchor / Schneider / Legrand: 16 way, SL.NO-3.4.7. | Each | 363.0 | 363.0 | 2.0 | False | None | None | False | None | False | 726.0 | 0 | 3301415 | 115080 | None | code137 | Supplying and fixing Superior Quality modular switch mounting poly carbonate plate with necessory supporting back plate with required no. of machine screws , bolts nuts etc. complte on existing metal / PVC box: 1-2 way , SL.NO-3.5.1. | Each | 137.0 | 137.0 | 24.0 | False | None | None | False | None | False | 3288.0 | 0 | 3301416 | 115080 | None | code138 | Supplying and fixing Superior Quality modular switch mounting poly carbonate plate with necessory supporting back plate with required no. of machine screws , bolts nuts etc. complte on existing metal / PVC box: 3 way, SL.NO-3.5.2. | Each | 161.0 | 161.0 | 10.0 | False | None | None | False | None | False | 1610.0 | 0 | 3301417 | 115080 | None | code139 | Supplying and fixing Superior Quality modular switch mounting poly carbonate plate with necessory supporting back plate with required no. of machine screws , bolts nuts etc. complte on existing metal / PVC box: 4-5 way, SL.NO-3.5.3. | Each | 175.0 | 175.0 | 35.0 | False | None | None | False | None | False | 6125.0 | 0 | 3301418 | 115080 | None | code140 | Supplying and fixing Superior Quality modular switch mounting poly carbonate plate with necessory supporting back plate with required no. of machine screws , bolts nuts etc. complte on existing metal / PVC box: 6 way, SL.NO-3.5.4. | Each | 234.0 | 234.0 | 45.0 | False | None | None | False | None | False | 10530.0 | 0 | 3301419 | 115080 | None | code141 | Supplying and fixing Superior Quality modular switch mounting poly carbonate plate with necessory supporting back plate with required no. of machine screws , bolts nuts etc. complte on existing metal / PVC box: 8 way , SL.NO-3.5.5. | Each | 284.0 | 284.0 | 12.0 | False | None | None | False | None | False | 3408.0 | 0 | 3301420 | 115080 | None | code142 | Supplying and fixing Superior Quality modular switch mounting poly carbonate plate with necessory supporting back plate with required no. of machine screws , bolts nuts etc. complte on existing metal / PVC box: 10-12 way, SL.NO-3.5.6. | Each | 344.0 | 344.0 | 10.0 | False | None | None | False | None | False | 3440.0 | 0 | 3301421 | 115080 | None | code143 | Supply and fixing of modular switch /socket /stepped electronic fan regulator/ dimmer telephone socket etc on existing modular switch plate : 6 Amp one way , SL.NO-3.6.1. | Each | 102.0 | 102.0 | 200.0 | False | None | None | False | None | False | 20400.0 | 0 | 3301422 | 115080 | None | code144 | Supply and fixing of modular switch /socket /stepped electronic fan regulator/ dimmer telephone socket etc on existing modular switch plate : 6 Amps 2 way, SL.NO-3.6.2. | Each | 166.0 | 166.0 | 2.0 | False | None | None | False | None | False | 332.0 | 0 | 3301423 | 115080 | None | code145 | Supply and fixing of modular switch /socket /stepped electronic fan regulator/ dimmer telephone socket etc on existing modular switch plate ; 6 Amps socket, SL.NO-3.6.3. | Each | 171.0 | 171.0 | 100.0 | False | None | None | False | None | False | 17100.0 | 0 | 3301424 | 115080 | None | code146 | Supply and fixing of modular switch /socket /stepped electronic fan regulator/ dimmer telephone socket etc on existing modular switch plate ; Stepped Fan Regulator, SL.NO-3.6.4. | Each | 357.0 | 357.0 | 12.0 | False | None | None | False | None | False | 4284.0 | 0 | 3301425 | 115080 | None | code147 | Supply and fixing of modular switch /socket /stepped electronic fan regulator/ dimmer telephone socket etc on existing modular switch plate : 16 Amps 1 way switch, SL.NO-3.6.8. | Each | 180.0 | 180.0 | 10.0 | False | None | None | False | None | False | 1800.0 | 0 | 3301426 | 115080 | None | code148 | Supply and fixing of modular switch /socket /stepped electronic fan regulator/ dimmer telephone socket etc on existing modular switch plate : 6 Amps Bell Push, SL.NO-3.7.8. | Each | 177.0 | 177.0 | 10.0 | False | None | None | False | None | False | 1770.0 | 0 | 3301427 | 115080 | None | code149 | Supply and fixing of modular switch /socket /stepped electronic fan regulator/ dimmer telephone socket etc on existing modular switch plate : 32 Amps DP Switch, SL.NO-3.7.9. | Each | 326.0 | 326.0 | 4.0 | False | None | None | False | None | False | 1304.0 | 0 | 3301428 | 115080 | None | code150 | Supply and fixing of modular switch /socket /stepped electronic fan regulator/ dimmer telephone socket etc on existing modular switch plate : 6/16 Amps universal socket, SL.NO-3.6.11. | Each | 236.0 | 236.0 | 12.0 | False | None | None | False | None | False | 2832.0 | 0 | 3301429 | 115080 | None | code151 | LUMINERIES & LIGHT FIXTURES & ACCESSORIES: Make : Panasonic/Phillips / Crompton; Led Light Fixture 2 feet - 9/10 W, SL.NO-11.3.1. | Each | 551.0 | 551.0 | 10.0 | False | None | None | False | None | False | 5510.0 | 0 | 3301430 | 115080 | None | code152 | LUMINERIES & LIGHT FIXTURES & ACCESSORIES: Make : Panasonic/Phillips / Crompton: Led Light Fixture 4 feet - 20/22 W, SL.NO-11.3.2. | Each | 690.0 | 690.0 | 45.0 | False | None | None | False | None | False | 31050.0 | 0 | 3301431 | 115080 | None | code153 | LUMINERIES & LIGHT FIXTURES & ACCESSORIES: Make : Panasonic/Phillips / Crompton; Supply of recess mounted rolling type LED square or round Light 12 watta, SL.NO-11.5.3 | Each | 885.0 | 885.0 | 4.0 | False | None | None | False | None | False | 3540.0 | 0 | 3301432 | 115080 | None | code154 | PANEL & DISTRIBUTION BOARDS; Distribution boards; Supplying and fixing regular MCB distribution Boards on Wall / wood board /flush mounting using required clamps bolts nuts etc with provision for fixing suitable type capacity MCB single phase / 3 phase / single door with powder coated paiting ; Double Door; 12Way SP &N, SL.NO-5.18.8. | Nos | 2329.0 | 2329.0 | 1.0 | False | None | None | False | None | False | 2329.0 | 0 | 3301433 | 115080 | None | code155 | PANEL & DISTRIBUTION BOARDS; Distribution boards; Supplying and fixing regular MCB distribution Boards on Wall / wood board /flush mounting using required clamps bolts nuts etc with provision for fixing suitable type capacity MCB single phase / 3 phase / single door with powder coated paiting ; Double Door; 6Way TP &N, SL.NO-5.18.10. | Nos | 4940.0 | 4940.0 | 1.0 | False | None | None | False | None | False | 4940.0 | 0 | 3301434 | 115080 | None | code156 | Supplying fixing & wiring earth leakage miniature circuit breaker (ELMCB) 240 / 450 V up to 300mA sensitivity on Existing / panel Board: 16 - 25 Amps 2 pole, SL.NO-5.20.1 | Nos | 4277.0 | 4277.0 | 1.0 | False | None | None | False | None | False | 4277.0 | 0 | 3301435 | 115080 | None | code157 | Supplying fixing & wiring earth leakage miniature circuit breaker (ELMCB) 240 / 450 V up to 300mA sensitivity on Existing / panel Board: 32 - 40 Amps 2 pole, SL.NO-5.20.2. | Nos | 4559.0 | 4559.0 | 3.0 | False | None | None | False | None | False | 13677.0 | 0 | 3301436 | 115080 | None | code158 | Supplying and Fixing miniature circuit breakers on existing MCB distribution boards using necessory fixing materials & C type curve indicator ON OFF energy cross 3 with short circuit breaking capacity of 10 K and complete wiring as required confirming to IEC 60898: 5 - 32 Amp SP, SL.NO-5.17.1. | Nos | 210.0 | 210.0 | 30.0 | False | None | None | False | None | False | 6300.0 | 0 | 3301437 | 115080 | None | code159 | Supplying and Fixing miniature circuit breakers on existing MCB distribution boards using necessory fixing materials & C type curve indicator ON OFF energy cross 3 with short circuit breaking capacity of 10 K and complete wiring as required confirming to IEC 60898: 5 - 32 Amp DP, SL.NO-5.17.4. | Nos | 1103.0 | 1103.0 | 2.0 | False | None | None | False | None | False | 2206.0 | 0 | 3301438 | 115080 | None | code160 | Supplying and Fixing miniature circuit breakers on existing MCB distribution boards using necessory fixing materials & C type curve indicator ON OFF energy cross 3 with short circuit breaking capacity of 10 K and complete wiring as required confirming to IEC 60898: 5 - 32 A TPN, SL.NO-5.17.7. | Nos | 1777.0 | 1777.0 | 1.0 | False | None | None | False | None | False | 1777.0 | 0 | 3301439 | 115080 | None | code161 | Supplying and Fixing miniature circuit breakers on existing MCB distribution boards using necessory fixing materials & C type curve indicator ON OFF energy cross 3 with short circuit breaking capacity of 10 K and complete wiring as required confirming to IEC 60898: 40 - 63 Amp TPN, SL.NO-5.17.9. | Nos | 2399.0 | 2399.0 | 1.0 | False | None | None | False | None | False | 2399.0 | 0 | 3301440 | 115080 | None | code162 | FANS & AIR CONDITIONERS: Make Fans : Crompton / Usha / Anchor; Supplying exhaust fan 0f 1440 RPM of300 mm (12") size with bracket blades complte for light duty suitable to operate on 230V 50 Hz AC Supply, SL.NO-7.1. | Each | 1542.0 | 1542.0 | 7.0 | False | None | None | False | None | False | 10794.0 | 0 | 3301441 | 115080 | None | code163 | Supplying capacitor type ceiling Fan complete with down rod blades shackle ,canopies etc. for operation on 230 Vots 50 cycles ,single phase AC supply confirming to ISS -374-1979 with double ball bearing system; 48 " Sweep; Economy model, SL.NO-7.3.1. | Each | 2085.0 | 2085.0 | 15.0 | False | None | None | False | None | False | 31275.0 | 0 | 3301442 | 115080 | None | code164 | COMPOUND WALL: Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness.-By Mechanical Means using Dozer-B)In area of light jungle. Page No. 7,Sl. No.2.5- A. VOL-3 | Sqm | 4.4 | 4.4 | 24.0 | False | None | None | False | None | False | 105.6 | 0 | 3301443 | 115080 | None | code165 | Earth work excavation for Foundation by mechanical means for all
works & depth upto 3 m, as per drawing and technical specifications,
including setting out, shoring, strutting, barricading, caution lights,
including dressing of excavated surfaces, disposing off or levelling the
excavated earth or sorting & stacking the selected earth for reuse in a
radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage
of machinery & other appurtenaces required to complete the work. sl.no-1.14.1, pg.no-8,volume-1.; In hard soil 90% of total excavated qty. Page No. 8,Sl. No.1.14..1,VOL-1 | Cum | 114.24 | 114.24 | 10.83 | False | None | None | False | None | False | 1237.2192 | 0 | 3301444 | 115080 | None | code166 | Earth work excavation for Foundation by mechanical means for all
works & depth upto 3 m, as per drawing and technical specifications,
including setting out, shoring, strutting, barricading, caution lights,
including dressing of excavated surfaces, disposing off or levelling the
excavated earth or sorting & stacking the selected earth for reuse in a
radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage
of machinery & other appurtenaces required to complete the work. sl.no-1.14.1, pg.no-8,volume-1.; In ordinary/soft rock without blasting, depth exceeding 1.5m, but not exceeding 3m. Sl.no-1.15.2, pg.no-9. (10% of total excavated qty) Sl. No.1.15..2,PG.NO-9,VOL-1 | Cum | 476.0 | 476.0 | 1.2 | False | None | None | False | None | False | 571.2 | 0 | 3301445 | 115080 | None | code167 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)-Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates. sl.no-2.1.2, pg.no-15. volume-1 | Cum | 6343.68 | 6343.68 | 1.65 | False | None | None | False | None | False | 10467.072 | 0 | 3301446 | 115080 | None | code168 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. Sl.no-1.9, page no-7.volume-I. | Cum | 297.92 | 297.92 | 2.35 | False | None | None | False | None | False | 700.112 | 0 | 3301447 | 115080 | None | code169 | Removal of Unserviceable Soil with Disposal upto a suitable
distance as directed by the Engineer incharge of work Sl. No. 3.1, Page No.17-volume-3. | Cum | 95.2 | 95.2 | 9.68 | False | None | None | False | None | False | 921.536 | 0 | 3301448 | 115080 | None | code170 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) Sl.no-5.4, page no-9,volume-2. | Cum | 7155.68 | 7155.68 | 6.21 | False | None | None | False | None | False | 44436.7728 | 0 | 3301449 | 115080 | None | code171 | Providing and constructing laterite size stone masonry including cost and conveyance of all materials curing etc complete as per specification I.S. 3620/1979 having compressive strength not less than 3.5 N/mm2 for saturated dry samples - For Super structure in CM 1:6. SL.NO-5.7,PG.NO-9, volume-2, | Cum | 7565.6 | 7565.6 | 3.98 | False | None | None | False | None | False | 30111.088 | 0 | 3301450 | 115080 | None | code172 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)-- Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates. Page 15, Sl. No.2.1.4, Volume-I, DPC. | Cum | 6963.04 | 6963.04 | 0.62 | False | None | None | False | None | False | 4317.0848 | 0 | 3301451 | 115080 | None | code173 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates-P-15 SI. No.2.2.3 VOL-1, FOOTING. | Cum | 7664.03 | 7664.03 | 0.49 | False | None | None | False | None | False | 3755.3747 | 0 | 3301452 | 115080 | None | code174 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.(including cost of form work & excluding cost of steel reinforcement, dowel bars)--M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. sl.no-2.5.2, pg.no-17, volume-I. COLUMN. | Cum | 13029.07 | 13029.07 | 0.5 | False | None | None | False | None | False | 6514.535 | 0 | 3301453 | 115080 | None | code175 | Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sl.No 8.7, Page No.42, Volume-2. | Sqm | 409.92 | 409.92 | 56.83 | False | None | None | False | None | False | 23295.7536 | 0 | 3301454 | 115080 | None | code176 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sl.No 8.30, Page No.46, Volume-2. | Sqm | 194.88 | 194.88 | 56.83 | False | None | None | False | None | False | 11075.0304 | 0 | 3301455 | 115080 | None | code177 | Fencing with G.I. barbed wire Angle iron post placed at required distance
embedded in cement concrete blocks, every 15th post, last but one
end post and corner post shall be strutted on both sides and end post
on one side only and provided with horizontal lines and two diagonals
interwoven with horizontal wires, of barbed wire weighing 9.38 kg per
100 m (minimum), between the two posts fitted and fixed with G.I.
staples, turn buckles etc. complete. (Cost of posts, struts, earth work
and concrete work to be paid for separately). Payment to be made per
metre cost of total length of barbed wire used. SL.NO-11.57, PG.NO-94, VOLUME-2. | m | 20.16 | 20.16 | 10.0 | False | None | None | False | None | False | 201.6 | 0 | 3301456 | 115080 | None | code178 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. a)Buildings-Sl. No.2.11 , Page No.18 Volume-I | Tonne | 100191.84 | 100191.84 | 0.12 | False | None | None | False | None | False | 12023.0208 | 0 | 3301457 | 115080 | None | code179 | Providing and fixing Steel work welded in built up sections/ framed
work, including cutting, hoisting, fixing in position and applying a priming
coat of approved steel primer using structural steel etc. as required.
In gratings, frames, guard bar, ladder, railings, brackets, gates and
similar works including cost of materials, labour, usage charges of
machinery complete as per specifications and as per directions of the
Engineer-in-Charge. sl.no-11.25.2, pg.no-84, volume-2. GATE. | Kg | 152.32 | 152.32 | 200.0 | False | None | None | False | None | False | 30464.0 | 0 | 3301458 | 115080 | None | code180 | NON SR: Providing and fixing in position precast ferrocement slab of 20mm thick and 600mm wide for storage rack suitable for storage of office files with required length including finishing,painting,labour charges,transportation,material charges any taxes applicable etc, complete as directed by the engineer incharge of the work. Concrete mix proportion : Equivalent to M25 strength,mild steel flats of size 20x3mm diameter are to be used for main and distribution reinforcement. Chicken mesh is to be provided in two layer for secondary reinforcement.(Approved rate of construction of minority welfare department Morarji desai residential pu college at Konaje,Mangalore, Dakshina kannada dist.) | Sqm | 2796.61 | 2796.61 | 142.56 | False | None | None | False | None | False | 398684.7216 | 0 |
|