createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1718697835722
version4
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee3270.00
emd200000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose02-07-2024 16:00:00
tenderQueryClose24-06-2024 16:00:00
technicalBidOpen04-07-2024 16:00:00
publishedDate18-06-2024 16:31:07
publishedByPostKHB_EE_CO_BNG
publishedByUserKPE11677 - SHIVASHANKARAPPA K H
bidValidityPeriod180
noOfCalls1
preBidMeetingDate25-06-2024 11:00:00
preBidMeetingYnTrue
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonSHIVASHANKARAPPA K H
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumber08022273511
mobileNumber8022273511
tenderSupplierListNone
tenderSchedule
createdTs1718697835742
version6
createdDateNone
modifiedDateNone
tenderNumberKHB/2024-25/BD/WORK_INDENT245
titleConstruction Of Sri D.Devaraj Aras Post Metric Girls Hostel Building 2nd Phase At Kodiyalbail, Sulya Taluk, Dakshina Kannada District
descriptionConstruction Of Sri D.Devaraj Aras Post Metric Girls Hostel Building 2nd Phase At Kodiyalbail, Sulya Taluk, Dakshina Kannada District
categoryWORKS
categoryTextWorks
ecv13073282.92
deptNameKarnataka Housing Board
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnFalse
location5488
locationNameKHB Central Office Bengaluru
provisionalAmount13073283.0
groupOverheadTotalNone
fileNumber126/2024-25
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17186978360000NoneNoneBuildingsConstruction Of Sri D.Devaraj Aras Post Metric Girls Hostel Building 2nd Phase At Kodiyalbail, Sulya Taluk, Dakshina Kannada District13073282.92
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3300973115076Nonecode01Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)--M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. sl.no-2.5.2, pg.no-17, volume-I. COLUMN, SECOND FLOOR.Cum13289.6513289.6514.75FalseNoneNoneFalseNoneFalse196022.33750
3300974115076Nonecode02Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)--M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. sl.no-2.5.2, pg.no-17, volume-I. COLUMN, TERRACE FLOOR.Cum13419.9413419.949.01FalseNoneNoneFalseNoneFalse120913.65940
3300975115076Nonecode03Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)-- Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates. Page 15, Sl. No.2.1.4, Volume-I, DUMMY COLUMN, TERRACE FLOOR.Cum12192.2812192.283.21FalseNoneNoneFalseNoneFalse39137.21880
3300976115076Nonecode04Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)--M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates sl.no-2.5.2, pg.no-17, volume-I. BEAM, SECOND FLOOR.Cum12507.9112507.9118.04FalseNoneNoneFalseNoneFalse225642.69640
3300977115076Nonecode05Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)--M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates sl.no-2.5.2, pg.no-17, volume-I. BEAM, TERRACE FLOOR.Cum12630.5412630.5413.04FalseNoneNoneFalseNoneFalse164702.24160
3300978115076Nonecode06Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)--M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. sl.no-2.5.2, pg.no-17, volume-I. SECOND FLOOR.Cum12507.9112507.917.1FalseNoneNoneFalseNoneFalse88806.1610
3300979115076Nonecode07Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)-- Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates. Page 15, Sl. No.2.1.4, Volume-I, CILL, SECOND FLOOR.Cum11363.6811363.682.37FalseNoneNoneFalseNoneFalse26931.92160
3300980115076Nonecode08Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)--M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. sl.no-2.5.2, pg.no-17, volume-I. SECOND FLOOR. STAIRCASECum11726.1611726.163.94FalseNoneNoneFalseNoneFalse46201.07040
3300981115076Nonecode09Providing and constructing laterite size stone masonry including cost and conveyance of all materials curing etc complete as per specification I.S. 3620/1979 having compressive strength not less than 3.5 N/mm2 for saturated dry samples - For Super structure in CM 1:6. SL.NO-5.7,PG.NO-9, volume-2, SECOND FLOORCum7716.917716.9165.89FalseNoneNoneFalseNoneFalse508467.19990
3300982115076Nonecode10Providing and constructing laterite size stone masonry including cost and conveyance of all materials curing etc complete as per specification I.S. 3620/1979 having compressive strength not less than 3.5 N/mm2 for saturated dry samples - For Super structure in CM 1:6. SL.NO-5.7,PG.NO-9, volume-2, TERRACE FLOORCum7792.577792.5711.12FalseNoneNoneFalseNoneFalse86653.37840
3300983115076Nonecode11Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.-Sl No.6.32, PageNo.17 Volume-II, SECOND FLOOR.Sqm1496.541496.54266.8016FalseNoneNoneFalseNoneFalse399279.2664640
3300984115076Nonecode12Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. S.No. 6.33, Page No.17, Volume-2. SECOND FLOOR.Sqm1406.291406.2978.64FalseNoneNoneFalseNoneFalse110590.64560
3300985115076Nonecode13Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. S.No. 6.33, Page No.17, Volume-2. TERRACE FLOOR.Sqm1420.081420.08111.0FalseNoneNoneFalseNoneFalse157628.880
3300986115076Nonecode14Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.sl.no-6.34, pg.no-17, volume-2. SECOND FLOOR.Sqm1261.211261.210.9FalseNoneNoneFalseNoneFalse1135.0890
3300987115076Nonecode15Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)--M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. sl.no-2.5.2, pg.no-17, volume-I. SLAB, SECOND FLOOR.Cum11726.1611726.1655.12FalseNoneNoneFalseNoneFalse646345.93920
3300988115076Nonecode16Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)--M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. sl.no-2.5.2, pg.no-17, volume-I. SLAB, TERRACEFLOOR.Cum11841.1311841.1323.02FalseNoneNoneFalseNoneFalse272582.81260
3300989115076Nonecode17Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)--M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. sl.no-2.5.2, pg.no-17, volume-I. CHAJJA, SECOND FLOORCum11335.2911335.294.61FalseNoneNoneFalseNoneFalse52255.68690
3300990115076Nonecode18Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. a)Buildings-Sl. No.2.11 , Page No.18 Volume-I, SECOND FLOOR.Tonne102195.68102195.6813.95FalseNoneNoneFalseNoneFalse1425629.7360
3300991115076Nonecode19Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. a)Buildings-Sl. No.2.11 , Page No.18 Volume-I, TERRACE FLOOR.Tonne103197.6103197.66.92FalseNoneNoneFalseNoneFalse714127.3920
3300992115076Nonecode20Providing Red Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. Sl.No 12.13.2, Page No.100,Volume- 2. SECOND FLOORCum113783.04113783.040.69FalseNoneNoneFalseNoneFalse78510.29760
3300993115076Nonecode21Providing Red Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. Sl.No 12.13.2, Page No.100,Volume- 2. TERRACE FLOORCum114898.56114898.560.08FalseNoneNoneFalseNoneFalse9191.88480
3300994115076Nonecode22Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross- section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame. sl.no-12.96, pg.no-112,volume-2. SECOND FLOOR.m734.56734.5663.5FalseNoneNoneFalseNoneFalse46644.560
3300995115076Nonecode23Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made). Sl. No.12.90, Page No. 110, Volume-2. SECOND FLOOR.Sqm7692.927692.929.0FalseNoneNoneFalseNoneFalse69236.280
3300996115076Nonecode24Providing & fixing of 2.5 track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 94mm width x 45mm height with reinforcement of 1mm thickness and Sash with overall size of 39mm x 58mm with GI reinforcement of 1.5mm and mesh sash of size 25mm x 42mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 1819mm x 1819mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)SL.NO-12.89, PG.NO-110, VOLUME-2. SECOND FLOOR.Sqm7483.867483.8629.7FalseNoneNoneFalseNoneFalse222270.6420
3300997115076Nonecode25Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)- SL.NO-12.85, PG.NO-109, VOLUME-2. SECOND FLOOR.Sqm6533.396533.3922.59FalseNoneNoneFalseNoneFalse147589.28010
3300998115076Nonecode26Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification.-35 mm thick both side commercial, Sl. No. 12.57.6,Page No. 105, Volume-2. SECOND FLOOR.Sqm3795.053795.0522.54FalseNoneNoneFalseNoneFalse85540.4270
3300999115076Nonecode27Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification.-35 mm thick both side commercial, Sl. No. 12.57.6,Page No. 105, Volume-2. TERRACE FLOOR.Sqm3832.263832.262.45FalseNoneNoneFalseNoneFalse9389.0370
3301000115076Nonecode28Providing and fixing to existing door frames Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames.- 30 mm thickness-Sl. No. 12.97.1,Page No. 112, Volume-2. SECOND FLOOR.Sqm3660.253660.2518.38FalseNoneNoneFalseNoneFalse67275.3950
3301001115076Nonecode29Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. sl.no-12.51, pg.no-104, volume-2. SECOND & TERRACE FLOOR.Nos.1160.681160.6820.0FalseNoneNoneFalseNoneFalse23213.60
3301002115076Nonecode30Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. SL.NO-12.58, PG.NO-105,VOLUME-2.Nos134.4134.410.0FalseNoneNoneFalseNoneFalse1344.00
3301003115076Nonecode31Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. SL.NO-12.60, PG.NO-105,VOLUME-2.Nos.1178.241178.2440.0FalseNoneNoneFalseNoneFalse47129.60
3301004115076Nonecode32Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. complete SL.NO-12.62, PG.NO-105,VOLUME-2.Nos.265.44265.4440.0FalseNoneNoneFalseNoneFalse10617.60
3301005115076Nonecode33Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete : 250x10mm, SL.NO-12.76.1, PG.NO-107,VOLUME-2.Each487.2487.240.0FalseNoneNoneFalseNoneFalse19488.00
3301006115076Nonecode34Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : 125x85x5.5mm.(heavy type) Sl.no-12.75.1, pg.no-107,volume-2.Nos.308.0308.040.0FalseNoneNoneFalseNoneFalse12320.00
3301007115076Nonecode35Providing and fixing bright finished brass butt hinges with necessary screws etc. complete :; 100x85x5.5mm.(heavy type) Sl.no-12.75.3, pg.no-107,volume-2.Nos.229.6229.630.0FalseNoneNoneFalseNoneFalse6888.00
3301008115076Nonecode36Providing and fixing MS Hold fasts (SL. No 285,Page No.A-21, Basic Rate Rs. 32.00), volume-2.Each35.8435.84120.0FalseNoneNoneFalseNoneFalse4300.80
3301009115076Nonecode37Providing and fixing PTMT door catcher of length 72 mm and dia. of 42 mm with suitable washers weighing not less than 33 gms. Sl.no-12.64, pg.no-105.volume-2.Nos61.661.610.0FalseNoneNoneFalseNoneFalse616.00
3301010115076Nonecode38Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding, Sl. No. 11.34A, Page No. 85,Volume-2. SECOND FLOOR.Kgs191.92191.921103.22FalseNoneNoneFalseNoneFalse211729.98240
3301011115076Nonecode39Providing 12 mm cement plaster with Cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer in-charge.. Sl. No. 8.6.1, Page No. 42, Volume-2. CEILING, SECOND FLOOR.Sqm369.0369.0485.13FalseNoneNoneFalseNoneFalse179012.970
3301012115076Nonecode40Providing 12 mm cement plaster with Cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer in-charge.. Sl. No. 8.6.1, Page No. 42, Volume-2. CEILING, TERRACE FLOOR.Sqm372.61372.6170.38FalseNoneNoneFalseNoneFalse26224.29180
3301013115076Nonecode41Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sl.No 8.7, Page No.42, Volume-2. INTERNAL WALL, SECOND FLOOR.Sqm418.12418.12808.5FalseNoneNoneFalseNoneFalse338050.020
3301014115076Nonecode42Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sl.No 8.7, Page No.42, Volume-2. INTERNAL WALL, TERRACE FLOOR.Sqm422.22422.2259.45FalseNoneNoneFalseNoneFalse25100.9790
3301015115076Nonecode43Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sl.No. 8.2.1, Page No.41, Volume- 2. SECOND FLOOR.Sqm337.01337.01223.27FalseNoneNoneFalseNoneFalse75244.22270
3301016115076Nonecode44Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sl. No. 8.9, Page No.42, Volume-2. SECOND FLOOR. EXTERNAL WALL.Sqm439.82439.82502.68FalseNoneNoneFalseNoneFalse221088.71760
3301017115076Nonecode45Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sl. No. 8.9, Page No.42, Volume-2. TERRACE FLOOR. EXTERNAL WALL.Sqm444.14444.14865.69FalseNoneNoneFalseNoneFalse384487.55660
3301018115076Nonecode46Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)-- Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates. Page 15, Sl. No.2.1.4, Volume-I, SECOND FLOOR.Cum7102.37102.39.48FalseNoneNoneFalseNoneFalse67329.8040
3301019115076Nonecode47Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)-- Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates. Page 15, Sl. No.2.1.4, Volume-I, TERRACE FLOOR.Cum7171.937171.931.11FalseNoneNoneFalseNoneFalse7960.84230
3301020115076Nonecode48Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications. Sl.No 7.18, Page No.23, Volume-2. SECOND FLOOR.Cum2304.222304.226.39FalseNoneNoneFalseNoneFalse14723.96580
3301021115076Nonecode49Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cat Eye, River Pink or equivalent. Sl.No 9.24, Page No.63 Volume-II, SECOND FLOOR.Sqm3258.123258.1252.94FalseNoneNoneFalseNoneFalse172484.87280
3301022115076Nonecode50Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cat Eye, River Pink or equivalent. Sl.No 9.24, Page No.63 Volume-II, TERRACE FLOOR.Sqm3290.073290.078.3FalseNoneNoneFalseNoneFalse27307.5810
3301023115076Nonecode51Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications.. sl.no-9.30, pg.no-64,volume-2. SECOND FLOOR.Sqm6086.716086.7123.97FalseNoneNoneFalseNoneFalse145898.43870
3301024115076Nonecode52Providing and laying vitrified floor tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm sl.no-9.12.2, pg.no-60.volume-2. SECOND FLOOR.Sqm1308.051308.05315.32FalseNoneNoneFalseNoneFalse412454.3260
3301025115076Nonecode53Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete.. Sl.No 9.11, Page No.60, Volume-2, SECOND FLOOR.Sqm1015.591015.5933.0FalseNoneNoneFalseNoneFalse33514.470
3301026115076Nonecode54Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg/m2, including pointing in white cement mixed with pigment of matching shade complete.. Sl.No 10.14, Page No.71, Volume-2. SECOND FLOOR.Sqm1263.491263.49223.27FalseNoneNoneFalseNoneFalse282099.41230
3301027115076Nonecode55Providing flooring with 25mm thick polished Cuddapah slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab , including cost of materials, labour, curing, polishing complete as per specifications. Sl.No 9.36, Page No.64, Volume-2. SECOND FLOOR.Sqm1884.961884.962.49FalseNoneNoneFalseNoneFalse4693.55040
3301028115076Nonecode56Providing and laying flooring and steps machine cut granite slabs 40 mm thick on cement mortar bed 1:6, 25 mm thick, and pointed with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar labour, curing complete as per specifications.. Sl.No 9.28 Page No.63, Volume-2. SECOND FLOOR.Sqm4888.334888.332.49FalseNoneNoneFalseNoneFalse12171.94170
3301029115076Nonecode57Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. Sl.No 8.51, Page No.50, Volume-2. SECOND FLOOR.Sqm114.24114.241293.62FalseNoneNoneFalseNoneFalse147783.14880
3301030115076Nonecode58Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. Sl.No 8.51, Page No.50, Volume-2. TERRACE FLOOR.Sqm115.36115.36129.83FalseNoneNoneFalseNoneFalse14977.18880
3301031115076Nonecode59Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Specialprimer applied @ 0.75 ltr /10 m² with paint of approved quality to givean even shade, after thoroughly brooming the surface to remove all dirt,dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sl.No 8.33.1, Page No.46, Volume-2. CEILING, SECOND FLOOR.Sqm180.5180.5485.13FalseNoneNoneFalseNoneFalse87565.9650
3301032115076Nonecode60Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Specialprimer applied @ 0.75 ltr /10 m² with paint of approved quality to givean even shade, after thoroughly brooming the surface to remove all dirt,dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sl.No 8.33.1, Page No.46, Volume-2. CEILING, TERRACE FLOOR.Sqm182.27182.2770.38FalseNoneNoneFalseNoneFalse12828.16260
3301033115076Nonecode61Finishing with Deluxe Multi surface paint system for interiors andexteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Specialprimer applied @ 0.75 ltr /10 m² with paint of approved quality to givean even shade, after thoroughly brooming the surface to remove all dirt,dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sl.No 8.33.1, Page No.46, Volume-2.INTERNAL WALL, SECOND FLOOR.Sqm180.5180.5808.5FalseNoneNoneFalseNoneFalse145934.250
3301034115076Nonecode62Finishing with Deluxe Multi surface paint system for interiors andexteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Specialprimer applied @ 0.75 ltr /10 m² with paint of approved quality to givean even shade, after thoroughly brooming the surface to remove all dirt,dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sl.No 8.33.1, Page No.46, Volume-2.INTERNAL WALL, TERRACE FLOOR.Sqm182.27182.2759.45FalseNoneNoneFalseNoneFalse10835.95150
3301035115076Nonecode63Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sl.No 8.30, Page No.46, Volume-2. EXTERNAL WALL, SECOND FLOOR.Sqm198.78198.78502.68FalseNoneNoneFalseNoneFalse99922.73040
3301036115076Nonecode64Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sl.No 8.30, Page No.46, Volume-2. EXTERNAL WALL, TERRACE FLOOR.Sqm200.73200.73865.69FalseNoneNoneFalseNoneFalse173769.95370
3301037115076Nonecode65Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sl.No 8.29, Page No.45,Volume-2. SECOND FLOOR.Sqm323.3323.310.05FalseNoneNoneFalseNoneFalse3249.1650
3301038115076Nonecode66Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sl.No 8.29, Page No.45,Volume-2. TERRACE FLOOR.Sqm326.47326.4717.31FalseNoneNoneFalseNoneFalse5651.19570
3301039115076Nonecode67Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sl.No 8.41,Page No.48, Volume-2. SECOND FLOOR.Sqm190.78190.7861.29FalseNoneNoneFalseNoneFalse11692.90620
3301040115076Nonecode68Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/ litre as per specifications and as per directions of Engineer in charge.Sl.No 8.55.1, Page No.51, Volume-2. SECOND FLOOR.Sqm63.9763.9758.6FalseNoneNoneFalseNoneFalse3748.6420
3301041115076Nonecode69Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/ litre as per specifications and as per directions of Engineer in charge.Sl.No 8.55.1, Page No.51, Volume-2. TERRACE FLOOR.Sqm64.664.66.37FalseNoneNoneFalseNoneFalse411.5020
3301042115076Nonecode70Polishing on wood work with ready mixed wax polish of approved brand and manufacture : New work to give an even surface including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.sl.no-8.47, pg.no-49. SECOND FLOOR.Sqm154.22154.2258.6FalseNoneNoneFalseNoneFalse9037.2920
3301043115076Nonecode71Polishing on wood work with ready mixed wax polish of approved brand and manufacture : New work to give an even surface including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.sl.no-8.47, pg.no-49. TERRACE FLOOR.Sqm155.74155.746.37FalseNoneNoneFalseNoneFalse992.06380
3301044115076Nonecode72Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge..Sl.No 11.28, Page No.83, Volume-2. SECOND FLOOR.Kg645.46645.4680.0FalseNoneNoneFalseNoneFalse51636.80
3301045115076Nonecode73Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 100 mm diameter. SL.NO-13.48, PG.NO-125, VOLUME-2. SECOND FLOOR.m332.44332.44138.0FalseNoneNoneFalseNoneFalse45876.720
3301046115076Nonecode74Providing and fixing of Laterite cladding tiles of size 230x75x10mm thick on 12mm thick cement mortar 1:3 (1 cement : 3 coarse sand) & jointed with Adhesive over rough plaster surface excluding cost of rough plastered surface. The work includes cost of all materials, labour charges for all items of work, usage charges for equipment, etc., complete as per specification. SL.NO-10.21, PG.NO-72, VOLUME-2. SECOND FLOOR.Sqm2488.152488.15120.41FalseNoneNoneFalseNoneFalse299598.14150
3301047115076Nonecode75Providing and laying 500x500x40 mm thick Turf paver on 150 mm thick sub grade of compacted bed of 20 mm thick nominal size stone aggregate and base course and filling with 150 mm thick fine sand, including spreading, well ramming, consolidating and finishing smooth etc. all complete as per direction of Engineer-in-charge.. SL.NO-9.16, PG.NO-61, VOLUME-2.Sqm806.4806.430.0FalseNoneNoneFalseNoneFalse24192.00
3301048115076Nonecode76Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in Granite, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete.SL.NO-10.4, PG.NO-69, VOLUME-2. SECOND FLOOR.m675.16675.167.0FalseNoneNoneFalseNoneFalse4726.120
3301049115076Nonecode77Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. Sl.No 11.16.2, Page No.82, Volume-2. TERRACE FLOOR.Kg169.58169.585791.8FalseNoneNoneFalseNoneFalse982173.4440
3301050115076Nonecode78Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05 %) total coated thickness with zinc coating 120 g/m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineerin- charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. Sl.No 7.38, Page No.26, Volume-2. TERRACE FLOOR.Sqm655.24655.24413.7FalseNoneNoneFalseNoneFalse271072.7880
3301051115076Nonecode79Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 g/m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete :. Crimp curve, Sl.No 7.39.5, Page No.27 Volume-2. TERRACE FLOOR.Sqm490.28490.2826.4FalseNoneNoneFalseNoneFalse12943.3920
3301052115076Nonecode80Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 g/m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete :. Ridges plain (500 - 600mm) , Sl.No 7.39.1, Page No.26 Volume-IIm520.27520.2780.0FalseNoneNoneFalseNoneFalse41621.60
3301053115076Nonecode81Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)-- Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates. Page 15, Sl. No.2.1.4, Volume-I, TERRACE FLOOR.Cum7171.937171.9328.3FalseNoneNoneFalseNoneFalse202965.6190
3301054115076Nonecode82Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6 kg/m2 to achieve final DFT (Dry Film Thickness) of 1mm including prime coat of epoxy primer @150 g/m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification.. sl.no-15.1, pg.no-149. volume-2. TERRACE FLOOR.Sqm942.49942.4941.2FalseNoneNoneFalseNoneFalse38830.5880
3301055115076Nonecode83Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sl.No 8.7, Page No.42, Volume-2. TERRACE FLOOR.Sqm422.22422.22412.11FalseNoneNoneFalseNoneFalse174001.08420
3301056115076Nonecode84Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove. Page 54, Sl. No.8.79, Volume-2, TERRACE FLOOR.m59.9959.99357.0FalseNoneNoneFalseNoneFalse21416.430
3301057115076Nonecode85PLUMBING AND SANITARY: Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests, Sl.No 14.1.1, Page No.131, Volume-IINos5470.085470.081.0FalseNoneNoneFalseNoneFalse5470.080
3301058115076Nonecode86Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid. Sl.No 14.3.1, Page No.131,, Volume-IINos6694.246694.244.0FalseNoneNoneFalseNoneFalse26776.960
3301059115076Nonecode87Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required: using White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer. Sl.No 14.7A, Page No.133, Volume-IINos4615.524615.525.0FalseNoneNoneFalseNoneFalse23077.60
3301060115076Nonecode88Providing and fixing 100 mm sand cast Iron grating for gully trap. Sl.No 14.29, Page No.136, Volume-IINos52.6452.6412.0FalseNoneNoneFalseNoneFalse631.680
3301061115076Nonecode89Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. Sl.No 13.15 Page No.119, Volume-IINos812.0812.020.0FalseNoneNoneFalseNoneFalse16240.00
3301062115076Nonecode90Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 g. Sl.No 13.13, Page No.119, Volume-IINos947.52947.5220.0FalseNoneNoneFalseNoneFalse18950.40
3301063115076Nonecode91Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end); 25 mm nominal bore, Sl.No 13.4.1 Page No.117, Volume-IINos614.88614.881.0FalseNoneNoneFalseNoneFalse614.880
3301064115076Nonecode92Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end); 32 mm nominal bore. Sl.No 13.4.2 Page No.117, Volume-IINos669.76669.761.0FalseNoneNoneFalseNoneFalse669.760
3301065115076Nonecode93Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end): 40 mm nominal bore. Sl.No 13.4.3 Page No.117, Volume-IINos786.24786.241.0FalseNoneNoneFalseNoneFalse786.240
3301066115076Nonecode94Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end); 50 mm nominal bore. Sl.No 13.4.4 Page No.117, Volume-IINos957.6957.61.0FalseNoneNoneFalseNoneFalse957.60
3301067115076Nonecode95Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end); 65 mm nominal bore. Sl.No 13.4.5 Page No.117, Volume-IINos1580.321580.321.0FalseNoneNoneFalseNoneFalse1580.320
3301068115076Nonecode96Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end): 80 mm nominal bore. Sl.No 13.4.6 Page No.117, Volume-IINos2326.242326.241.0FalseNoneNoneFalseNoneFalse2326.240
3301069115076Nonecode97Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. Sl.No 14.31, Page No.136, Volume-IINos1366.41366.44.0FalseNoneNoneFalseNoneFalse5465.60
3301070115076Nonecode98600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g. Sl.No 14.40.2, Page No.137, Volume-IINos555.52555.5210.0FalseNoneNoneFalseNoneFalse5555.20
3301071115076Nonecode99Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : (150mm diameter) SL.NO-13.9.2, PG.NO-118.VOLUME-2.Nos312.48312.485.0FalseNoneNoneFalseNoneFalse1562.40
3301072115076Nonecode100Providing and fixing CP Brass 15 mm nominal dia Single lever telephonic wall mixer of quality & make as approved by Engineer in charge.. Sl.no-14.22B,pg.no-135, volume-2.Each6229.446229.445.0FalseNoneNoneFalseNoneFalse31147.20
3301073115076Nonecode101Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for:-PVC pipes 160mm dia., 6 kg/sqcm & class 3, Sl.No 1.9-M0I0I, Page No.134, BWSSBm670.88670.882.0FalseNoneNoneFalseNoneFalse1341.760
3301074115076Nonecode102Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for:-PVC pipes 110mm dia., 6 kg/sqcm & class 3- Sl.No 1.7-M0I0G, Page No.134, BWSSBm441.28441.2820.0FalseNoneNoneFalseNoneFalse8825.60
3301075115076Nonecode103Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for:-PVC pipes 90mm dia., 6 kg/sqcm & class 3 . Sl.No 1.6- M010F, Page No.134, BWSSBm314.72314.7215.0FalseNoneNoneFalseNoneFalse4720.80
3301076115076Nonecode104Providing and fixing Chorinated Poly Venly Cloride (CPVC) pipes conforming to IS15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr. spacing. This includes jointing of pipes and fitting with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete. (concealed work including cutting chases and good the walls etc), For 50 mm dia, Sl.No 13.31.6, VOL-2-m874.72874.7210.0FalseNoneNoneFalseNoneFalse8747.20
3301077115076Nonecode105Providing and fixing Chorinated Poly Venly Cloride (CPVC) pipes conforming to IS15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr. spacing. This includes jointing of pipes and fitting with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete. (concealed work including cutting chases and good the walls etc), For 32 mm dia, Sl.No 13.32.4, VOL-2.m623.84623.8468.0FalseNoneNoneFalseNoneFalse42421.120
3301078115076Nonecode106Providing and fixing Chorinated Poly Venly Cloride (CPVC) pipes conforming to IS15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr. spacing. This includes jointing of pipes and fitting with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete. (concealed work including cutting chases and good the walls etc), For 25 mm dia, Sl.No 13.32.3, VOL-2m534.24534.2448.0FalseNoneNoneFalseNoneFalse25643.520
3301079115076Nonecode107Providing and fixing Chorinated Poly Venly Cloride (CPVC) pipes conforming to IS15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr. spacing. This includes jointing of pipes and fitting with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete. (concealed work including cutting chases and good the walls etc), For 20 mm dia, Sl.No 13.32.2, VOL-2.m424.48424.4830.0FalseNoneNoneFalseNoneFalse12734.40
3301080115076Nonecode108Providing PVC-U INDIVIDUAL U.G.D House service connection (which shall be laid from inside the customer property ) which includes: a) Supply of PVC-U pipe (b) providing and fixing of 315 mm dia the PE Inspection chambres with lid consisting of inlet & outlet arrangements with base, riser of min. 0.42 m depth which includes earth work, fixing in CC-1:2:4 with appurtenances., complete. (c) civil works like Earthwork excavation for the pipeline trenches for laying of PVC-U pipes for the house connections in all types of soils , disintegrated rock,soft rock, hard rock, including cutting of any road using , crossing drains, compound, Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, c.c. wood work, steel work, including T & P and scaffolding wherever necessary sorting the dismantled material, disposal of unserviceable and stacking the serviceable material with all lifts and lead , restoring the damaged portions inside or outside the property premises, refilling the portions of trenches that are dug open including linking to existing sewer network with appurtenances. complete.Supply and fixing of SFRC machinhole cover (Medium Duty) made as per IS to suit existing damaged machinhole cover after removing the debries from inside and outside the existing machinhole etc. with all lead and lifts. 110 mm dia, INSPECTION CHAMBER (450x450mm), Sl.No 60.1 & 61, Page No.179, BWSSBNos8761.768761.762.0FalseNoneNoneFalseNoneFalse17523.520
3301081115076Nonecode109KSRB 13-11 : Providing and placing on terrace, polyethylene water storage tanks as per IS 12701 : 1996 with manhole lid and suitable locking arrangements, making holes of suitable diameter for inlet, outlet and over flow pipes, including cost of all materials, labour, transport charges, HOM and testing complete as per specifications. Specification No.KBS 13.22, Sl. No. 13.34, vol-2,Ltr10.0810.085000.0FalseNoneNoneFalseNoneFalse50400.00
3301082115076Nonecode110Supplying, installation, testing and commissioning of solar hot water heater comprising of solar Flat Plate Collector (FPC) of size 2120x1040x100mm and stainless steel hot water storage tank with stainless steel heat exchanger absorber made of copper sheet and copper tube of following capacity aluminium box collector with appropriate capacity electrical back up arrangement excluding inlet and out let pipes. SS Model with 100mm thick of 48Kg/M3density Rock wool insulation with 22SWG Aluminium cladding. 200 L. SL.NO-7.3.2. PG.NO-27. CHAPTER-7.Each54297.654297.61.0FalseNoneNoneFalseNoneFalse54297.60
3301083115076Nonecode111INTERNAL WIRING & POWER POINTS: PVC Conduit and its Accessories; Concealed Conduit System: Supplying heavy gauge PVC conduit pipe … mm dia confirming to IS 2509 with suitable size bends, metal / PVC junction boxes adhesive paste etc. and running before Concreting the Slab. The Conduit should be tied to the reenforcement Rods by using binding wires and the unused ways of Junction boxes should be covered using PVC End enclosures .run with 18 SWG GI finish wire wherever it is necessory: 19/20mm Dia 2mm Thick. SL.NO-1.2.1.Mtr66.066.0300.0FalseNoneNoneFalseNoneFalse19800.00
3301084115076Nonecode112INTERNAL WIRING & POWER POINTS: PVC Conduit and its Accessories; Concealed Conduit System: Supplying heavy gauge PVC conduit pipe … mm dia confirming to IS 2509 with suitable size bends, metal / PVC junction boxes adhesive paste etc. and running before Concreting the Slab. The Conduit should be tied to the reenforcement Rods by using binding wires and the unused ways of Junction boxes should be covered using PVC End enclosures .run with 18 SWG GI finish wire wherever it is necessory: 25mm dia 2mm Thick. SL,NO-1.2.2.Mtr78.078.0450.0FalseNoneNoneFalseNoneFalse35100.00
3301085115076Nonecode113Supplying heavy gauge PVC conduit pipe … mm dia confirming to IS 2509 with suitable size bends, metal / PVC junction boxes adhesive paste etc. by groove cutting in the wall and fixing by bracing U or J hooks and plastering upto wall surface and .run with 18 SWG GI finish wire wherever it is necessory; 19/20mm Dia 2mm Thick, SL.NO-1.3.1.Mtr68.068.0350.0FalseNoneNoneFalseNoneFalse23800.00
3301086115076Nonecode114Supplying heavy gauge PVC conduit pipe … mm dia confirming to IS 2509 with suitable size bends, metal / PVC junction boxes adhesive paste etc. by groove cutting in the wall and fixing by bracing U or J hooks and plastering upto wall surface and .run with 18 SWG GI finish wire wherever it is necessory; 25mm dia 2mm Thick, SL.NO-1.3.2.Mtr79.079.0400.0FalseNoneNoneFalseNoneFalse31600.00
3301087115076Nonecode115Supplying and fixing PVC/ Metal Conduit Deep Junction Boxes; 19/20 mm Deep Junction Box. SL.NO-1.5.1.Each49.049.0100.0FalseNoneNoneFalseNoneFalse4900.00
3301088115076Nonecode116Supplying and fixing PVC/ Metal Conduit Deep Junction Boxes; 25 mm Deep Junction Box.SL.NO-1.5.2.Each56.056.050.0FalseNoneNoneFalseNoneFalse2800.00
3301089115076Nonecode117Supplying and fixing PVC Casing and capping on the wall or ceiling using materials like bend , screws at an interval 0f 300 mm etc: 20 mm, SL.NO-1.8.1.Mtr28.028.050.0FalseNoneNoneFalseNoneFalse1400.00
3301090115076Nonecode118Supplying and fixing PVC Casing and capping on the wall or ceiling using materials like bend , screws at an interval 0f 300 mm etc; 25 mm, SL.NO-1.8.2.Mtr35.035.040.0FalseNoneNoneFalseNoneFalse1400.00
3301091115076Nonecode119Supplying PVC /GI flexible conduit pipe …. Mm dia fixing on surface cover inverted tapared wodden plugs or phill plugs or rawl plugs and clamped using heavy guage saddles in an interval of 300 mm using NF screws and on the eaiter end of the pipe terminated properly: 20 mm, SL.NO-1.9.1.Mtr19.019.070.0FalseNoneNoneFalseNoneFalse1330.00
3301092115076Nonecode120Supplying PVC /GI flexible conduit pipe …. Mm dia fixing on surface cover inverted tapared wodden plugs or phill plugs or rawl plugs and clamped using heavy guage saddles in an interval of 300 mm using NF screws and on the eaiter end of the pipe terminated properly: 25 mm, SL.NO-1.9.2.Mtr22.022.070.0FalseNoneNoneFalseNoneFalse1540.00
3301093115076Nonecode121Supply & Fixing of Metal fan box with round Hook, SL.NO-1.13.Each117.0117.025.0FalseNoneNoneFalseNoneFalse2925.00
3301094115076Nonecode122Wires & Cables: Point wiring using copper wire without Switch: Supplying and wiring adopting loop system in existing PVC conduit/casing capping, using copper FRLS PVC insulated multi strand 2 x 1.5 sq.mm copper wire without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/pvc round block complete for each outlet.: Make : KEI / Polycab/ Finolex: Short point upto 3 Mtd. From Tapping point to outlet via switch box.Point269.0269.060.0FalseNoneNoneFalseNoneFalse16140.00
3301095115076Nonecode123Wires & Cables: Point wiring using copper wire without Switch: Supplying and wiring adopting loop system in existing PVC conduit/casing capping, using copper FRLS PVC insulated multi strand 2 x 1.5 sq.mm copper wire without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/pvc round block complete for each outlet.: Make : KEI / Polycab/ Finolex: Medium point above 3 Mts upto 6 Mts. From tapping point to outlet via switch box. SL.NO-2.2.2.Point379.0379.071.0FalseNoneNoneFalseNoneFalse26909.00
3301096115076Nonecode124Wires & Cables: Point wiring using copper wire without Switch: Supplying and wiring adopting loop system in existing PVC conduit/casing capping, using copper FRLS PVC insulated multi strand 2 x 1.5 sq.mm copper wire without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/pvc round block complete for each outlet.: Make : KEI / Polycab/ Finolex; Long point above 6 Mts. Upto 10 Mts. From tapping of point to outlet via switch box. SL.NO-2.2.3.Point555.0555.020.0FalseNoneNoneFalseNoneFalse11100.00
3301097115076Nonecode125Wires & Cables: Point wiring using copper wire without Switch: Supplying and wiring adopting loop system in existing PVC conduit/casing capping, using copper FRLS PVC insulated multi strand 2 x 1.5 sq.mm copper wire without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/pvc round block complete for each outlet.: Make : KEI / Polycab/ Finolex; Two outlet in a row above 3 Mts upto 6 Mts, from tapping point to outlet via switch box. SL.NO-2.1.4.Point677.0677.02.0FalseNoneNoneFalseNoneFalse1354.00
3301098115076Nonecode126Wires & Cables: Point wiring using copper wire without Switch: Supplying and wiring adopting loop system in existing PVC conduit/casing capping, using copper FRLS PVC insulated multi strand 2 x 1.5 sq.mm copper wire without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/pvc round block complete for each outlet.: Make : KEI / Polycab/ Finolex: Three outlet in a row, above 6 Mts. Upto 10 Mts. From tapping point to outlet via switch box. SL.NO-2.1Point989.0989.06.0FalseNoneNoneFalseNoneFalse5934.00
3301099115076Nonecode127Wiring for Lighting/ Power Circuit using one of PVC insulated 1100V grade, multistrand Copper conductor 1C cable in open or Concealed system of Wiring: 1.5 Sqmm. SL.NO-2.3.2.Mtr26.026.02200.0FalseNoneNoneFalseNoneFalse57200.00
3301100115076Nonecode128Wiring for Lighting/ Power Circuit using one of PVC insulated 1100V grade, multistrand Copper conductor 1C cable in open or Concealed system of Wiring: 2.5Sqmm. SL.NO-2.3.3.Mtr42.042.01800.0FalseNoneNoneFalseNoneFalse75600.00
3301101115076Nonecode129Wiring for Lighting/ Power Circuit using one of PVC insulated 1100V grade, multistrand Copper conductor 1C cable in open or Concealed system of Wiring: 4Sqmm, SL.NO-2.3.4.Mtr63.063.0200.0FalseNoneNoneFalseNoneFalse12600.00
3301102115076Nonecode130Wiring for Lighting/ Power Circuit using one of PVC insulated 1100V grade, multistrand Copper conductor 1C cable in open or Concealed system of Wiring; 6 sqmm , SL.NO-2.3.5.Mtr92.092.0100.0FalseNoneNoneFalseNoneFalse9200.00
3301103115076Nonecode131Wiring for Lighting/ Power Circuit using one of PVC insulated 1100V grade, multistrand Copper conductor 1C cable in open or Concealed system of Wiring: 10Sqmm, SL.NO-2.3.6.Mtr167.0167.080.0FalseNoneNoneFalseNoneFalse13360.00
3301104115076Nonecode132Wiring for Lighting/ Power Circuit using one of PVC insulated 1100V grade, multistrand Copper conductor 1C cable in open or Concealed system of Wiring: 16Sqmm, SL.NO-2.3.7.Mtr318.0318.080.0FalseNoneNoneFalseNoneFalse25440.00
3301105115076Nonecode133Switches Sockets and Accessories: Supplying and Flush mounting Powder coated / galvanised metal box suitable for mounting modular switch plates . The Box should be firmly flush mounted after due groove cutting in brick / Stone / C.C wall: Make : Anchor / Schneider / Legrand: 1-2 way , SL.NO-3.4.1.Each138.0138.024.0FalseNoneNoneFalseNoneFalse3312.00
3301106115076Nonecode134Switches Sockets and Accessories: Supplying and Flush mounting Powder coated / galvanised metal box suitable for mounting modular switch plates . The Box should be firmly flush mounted after due groove cutting in brick / Stone / C.C wall: Make : Anchor / Schneider / Legrand; 3 way, SL.NO-3.4.2.Each159.0159.010.0FalseNoneNoneFalseNoneFalse1590.00
3301107115076Nonecode135Switches Sockets and Accessories: Supplying and Flush mounting Powder coated / galvanised metal box suitable for mounting modular switch plates . The Box should be firmly flush mounted after due groove cutting in brick / Stone / C.C wall: Make : Anchor / Schneider / Legrand: 4-5 way, SL.NO-3.4.3.Each177.0177.035.0FalseNoneNoneFalseNoneFalse6195.00
3301108115076Nonecode136Switches Sockets and Accessories: Supplying and Flush mounting Powder coated / galvanised metal box suitable for mounting modular switch plates . The Box should be firmly flush mounted after due groove cutting in brick / Stone / C.C wall: Make : Anchor / Schneider / Legrand: 6 way, SL.NO-3.4.4.Each220.0220.045.0FalseNoneNoneFalseNoneFalse9900.00
3301109115076Nonecode137Switches Sockets and Accessories: Supplying and Flush mounting Powder coated / galvanised metal box suitable for mounting modular switch plates . The Box should be firmly flush mounted after due groove cutting in brick / Stone / C.C wall: Make : Anchor / Schneider / Legrand: 8 way , SL.NO-3.4.5.Each261.0261.012.0FalseNoneNoneFalseNoneFalse3132.00
3301110115076Nonecode138Switches Sockets and Accessories: Supplying and Flush mounting Powder coated / galvanised metal box suitable for mounting modular switch plates . The Box should be firmly flush mounted after due groove cutting in brick / Stone / C.C wall: Make : Anchor / Schneider / Legrand: 12 way, SL.NO-3.4.6.Each319.0319.010.0FalseNoneNoneFalseNoneFalse3190.00
3301111115076Nonecode139Switches Sockets and Accessories: Supplying and Flush mounting Powder coated / galvanised metal box suitable for mounting modular switch plates . The Box should be firmly flush mounted after due groove cutting in brick / Stone / C.C wall: Make : Anchor / Schneider / Legrand: 16 way, SL.NO-3.4.7.Each363.0363.02.0FalseNoneNoneFalseNoneFalse726.00
3301112115076Nonecode140Supplying and fixing Superior Quality modular switch mounting poly carbonate plate with necessory supporting back plate with required no. of machine screws , bolts nuts etc. complte on existing metal / PVC box: 1-2 way , SL.NO-3.5.1.Each137.0137.024.0FalseNoneNoneFalseNoneFalse3288.00
3301113115076Nonecode141Supplying and fixing Superior Quality modular switch mounting poly carbonate plate with necessory supporting back plate with required no. of machine screws , bolts nuts etc. complte on existing metal / PVC box: 3 way, SL.NO-3.5.2.Each161.0161.010.0FalseNoneNoneFalseNoneFalse1610.00
3301114115076Nonecode142Supplying and fixing Superior Quality modular switch mounting poly carbonate plate with necessory supporting back plate with required no. of machine screws , bolts nuts etc. complte on existing metal / PVC box: 4-5 way, SL.NO-3.5.3.Each175.0175.035.0FalseNoneNoneFalseNoneFalse6125.00
3301115115076Nonecode143Supplying and fixing Superior Quality modular switch mounting poly carbonate plate with necessory supporting back plate with required no. of machine screws , bolts nuts etc. complte on existing metal / PVC box: 6 way, SL.NO-3.5.4.Each234.0234.045.0FalseNoneNoneFalseNoneFalse10530.00
3301116115076Nonecode144Supplying and fixing Superior Quality modular switch mounting poly carbonate plate with necessory supporting back plate with required no. of machine screws , bolts nuts etc. complte on existing metal / PVC box: 8 way , SL.NO-3.5.5.Each284.0284.012.0FalseNoneNoneFalseNoneFalse3408.00
3301117115076Nonecode145Supplying and fixing Superior Quality modular switch mounting poly carbonate plate with necessory supporting back plate with required no. of machine screws , bolts nuts etc. complte on existing metal / PVC box: 10-12 way, SL.NO-3.5.6.Each344.0344.010.0FalseNoneNoneFalseNoneFalse3440.00
3301118115076Nonecode146Supply and fixing of modular switch /socket /stepped electronic fan regulator/ dimmer telephone socket etc on existing modular switch plate : 6 Amp one way , SL.NO-3.6.1.Each102.0102.0200.0FalseNoneNoneFalseNoneFalse20400.00
3301119115076Nonecode147Supply and fixing of modular switch /socket /stepped electronic fan regulator/ dimmer telephone socket etc on existing modular switch plate : 6 Amps 2 way, SL.NO-3.6.2.Each166.0166.02.0FalseNoneNoneFalseNoneFalse332.00
3301120115076Nonecode148Supply and fixing of modular switch /socket /stepped electronic fan regulator/ dimmer telephone socket etc on existing modular switch plate ; 6 Amps socket, SL.NO-3.6.3.Each171.0171.0100.0FalseNoneNoneFalseNoneFalse17100.00
3301121115076Nonecode149Supply and fixing of modular switch /socket /stepped electronic fan regulator/ dimmer telephone socket etc on existing modular switch plate ; Stepped Fan Regulator, SL.NO-3.6.4.Each357.0357.012.0FalseNoneNoneFalseNoneFalse4284.00
3301122115076Nonecode150Supply and fixing of modular switch /socket /stepped electronic fan regulator/ dimmer telephone socket etc on existing modular switch plate : 16 Amps 1 way switch, SL.NO-3.6.8.Each180.0180.010.0FalseNoneNoneFalseNoneFalse1800.00
3301123115076Nonecode151Supply and fixing of modular switch /socket /stepped electronic fan regulator/ dimmer telephone socket etc on existing modular switch plate : 6 Amps Bell Push, SL.NO-3.7.8.Each177.0177.010.0FalseNoneNoneFalseNoneFalse1770.00
3301124115076Nonecode152Supply and fixing of modular switch /socket /stepped electronic fan regulator/ dimmer telephone socket etc on existing modular switch plate : 32 Amps DP Switch, SL.NO-3.7.9.Each326.0326.04.0FalseNoneNoneFalseNoneFalse1304.00
3301125115076Nonecode153Supply and fixing of modular switch /socket /stepped electronic fan regulator/ dimmer telephone socket etc on existing modular switch plate : 6/16 Amps universal socket, SL.NO-3.6.11.Each236.0236.012.0FalseNoneNoneFalseNoneFalse2832.00
3301126115076Nonecode154LUMINERIES & LIGHT FIXTURES & ACCESSORIES: Make : Panasonic/Phillips / Crompton; Led Light Fixture 2 feet - 9/10 W, SL.NO-11.3.1.Each551.0551.010.0FalseNoneNoneFalseNoneFalse5510.00
3301127115076Nonecode155LUMINERIES & LIGHT FIXTURES & ACCESSORIES: Make : Panasonic/Phillips / Crompton: Led Light Fixture 4 feet - 20/22 W, SL.NO-11.3.2.Each690.0690.045.0FalseNoneNoneFalseNoneFalse31050.00
3301128115076Nonecode156LUMINERIES & LIGHT FIXTURES & ACCESSORIES: Make : Panasonic/Phillips / Crompton; Supply of recess mounted rolling type LED square or round Light 12 watta, SL.NO-11.5.3Each885.0885.04.0FalseNoneNoneFalseNoneFalse3540.00
3301129115076Nonecode157PANEL & DISTRIBUTION BOARDS; Distribution boards; Supplying and fixing regular MCB distribution Boards on Wall / wood board /flush mounting using required clamps bolts nuts etc with provision for fixing suitable type capacity MCB single phase / 3 phase / single door with powder coated paiting ; Double Door; 12Way SP &N, SL.NO-5.18.8.Nos2329.02329.01.0FalseNoneNoneFalseNoneFalse2329.00
3301130115076Nonecode158PANEL & DISTRIBUTION BOARDS; Distribution boards; Supplying and fixing regular MCB distribution Boards on Wall / wood board /flush mounting using required clamps bolts nuts etc with provision for fixing suitable type capacity MCB single phase / 3 phase / single door with powder coated paiting ; Double Door; 6Way TP &N, SL.NO-5.18.10.Nos4940.04940.01.0FalseNoneNoneFalseNoneFalse4940.00
3301131115076Nonecode159Supplying fixing & wiring earth leakage miniature circuit breaker (ELMCB) 240 / 450 V up to 300mA sensitivity on Existing / panel Board: 16 - 25 Amps 2 pole, SL.NO-5.20.1Nos4277.04277.01.0FalseNoneNoneFalseNoneFalse4277.00
3301132115076Nonecode160Supplying fixing & wiring earth leakage miniature circuit breaker (ELMCB) 240 / 450 V up to 300mA sensitivity on Existing / panel Board: 32 - 40 Amps 2 pole, SL.NO-5.20.2.Nos4559.04559.03.0FalseNoneNoneFalseNoneFalse13677.00
3301133115076Nonecode161Supplying and Fixing miniature circuit breakers on existing MCB distribution boards using necessory fixing materials & C type curve indicator ON OFF energy cross 3 with short circuit breaking capacity of 10 K and complete wiring as required confirming to IEC 60898: 5 - 32 Amp SP, SL.NO-5.17.1.Nos210.0210.030.0FalseNoneNoneFalseNoneFalse6300.00
3301134115076Nonecode162Supplying and Fixing miniature circuit breakers on existing MCB distribution boards using necessory fixing materials & C type curve indicator ON OFF energy cross 3 with short circuit breaking capacity of 10 K and complete wiring as required confirming to IEC 60898: 5 - 32 Amp DP, SL.NO-5.17.4.Nos1103.01103.02.0FalseNoneNoneFalseNoneFalse2206.00
3301135115076Nonecode163Supplying and Fixing miniature circuit breakers on existing MCB distribution boards using necessory fixing materials & C type curve indicator ON OFF energy cross 3 with short circuit breaking capacity of 10 K and complete wiring as required confirming to IEC 60898: 5 - 32 A TPN, SL.NO-5.17.7.Nos1777.01777.01.0FalseNoneNoneFalseNoneFalse1777.00
3301136115076Nonecode164Supplying and Fixing miniature circuit breakers on existing MCB distribution boards using necessory fixing materials & C type curve indicator ON OFF energy cross 3 with short circuit breaking capacity of 10 K and complete wiring as required confirming to IEC 60898: 40 - 63 Amp TPN, SL.NO-5.17.9.Nos2399.02399.01.0FalseNoneNoneFalseNoneFalse2399.00
3301137115076Nonecode165FANS & AIR CONDITIONERS: Make Fans : Crompton / Usha / Anchor; Supplying exhaust fan 0f 1440 RPM of300 mm (12") size with bracket blades complte for light duty suitable to operate on 230V 50 Hz AC Supply, SL.NO-7.1.Each1542.01542.022.0FalseNoneNoneFalseNoneFalse33924.00
3301138115076Nonecode166Supplying capacitor type ceiling Fan complete with down rod blades shackle ,canopies etc. for operation on 230 Vots 50 cycles ,single phase AC supply confirming to ISS -374-1979 with double ball bearing system; 48 " Sweep; Economy model, SL.NO-7.3.1.Each2085.02085.010.0FalseNoneNoneFalseNoneFalse20850.00
3301139115076Nonecode167NON SR: Providing and fixing in position precast ferrocement slab of 20mm thick and 600mm wide for storage rack suitable for storage of office files with required length including finishing,painting,labour charges,transportation,material charges any taxes applicable etc, complete as directed by the engineer incharge of the work. Concrete mix proportion : Equivalent to M25 strength,mild steel flats of size 20x3mm diameter are to be used for main and distribution reinforcement. Chicken mesh is to be provided in two layer for secondary reinforcement. (Approved rate of construction of minority welfare department Morarji desai residential pu college at Konaje,Mangalore, Dakshina kannada dist.)Sqm2796.612796.61142.56FalseNoneNoneFalseNoneFalse398684.72160
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17186978370000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17186978370000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17186978370000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17186978370000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17186978370000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
17186978450000NoneNoneELIGIBILITYThe tender document is part and parcel of the agreement.None
17186978490000NoneNoneELIGIBILITYThe contractor shall obtain insurance coverage for all the workers deployed for this work.None
17186978550000NoneNoneELIGIBILITYFurther details of the work or any clarifications can be obtained from the office of the Executive Engineer (Central office), KHB, Cauvery Bhavan, K.G. Road, Bangalore Ph: 080-22273511 ext-317,None
17186978640000NoneNoneELIGIBILITYThe intending bidders are requested to note that they should abide by the detailed instructions and conditions contained in the Tender documents and further modifications done if any.None
17186978710000NoneNoneELIGIBILITYCorrigendum/modification/corrections, if any, will be published in the e procurement Web sites only.None
17186978740000NoneNoneELIGIBILITYKHB reserves the right to withdraw or cancel this invitation to BID/Tender without assigning any reason whatsoeverNone
17186978770000NoneNoneELIGIBILITYThe bidder shall study the Tender document Carefully and quote the ratesNone
17186978810000NoneNoneELIGIBILITYAll scanned documents to be uploaded shall be in original and are to be produced to the Executive Engineer to verify the documents within 3 days from the day of opening of Technical bid for verification, if required.None
17186979820000NoneNoneELIGIBILITYDrawings uploaded are only for Tender Purpose only.None
17186979850000NoneNoneELIGIBILITYGST shall be added separately in the estimate.None
17186979890000NoneNoneELIGIBILITYGST shall be paid to the tendered amount separately.None
17186979930000NoneNoneELIGIBILITYThe bidder should maintain register of laborers deployed and wages paid for the workers and shall produce the documents whenever called for by the competent authority. Remittance towards PF shall be commensurate with the labour component of the work involved.None
17186979960000NoneNoneELIGIBILITYThe bidder shall give an undertaking that they would abide by the provisions of employees provident fund and shall remit PF of labourers to the respective PF offices or else KHB have the right to deduct the PF amount from the work bills and remit the same to respective PF offices.None
17186980010000NoneNoneELIGIBILITYThe contractor shall quote his rates inclusive of PF as per the applicable rate as issued by the PF department from time to timeNone
17186980070000NoneNoneELIGIBILITYThe successful bidder shall give an under taking that they would abide by the provisions of the Employees Provident Fund Act.None
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneMinimum financial turnover (civil engineering construction works) not less than two times the annual payments from this contract (Rs. xxxxx Lakhs)NoneNone
NoneNoneNoneNoneSatisfactoriy completed (atleast 90%) as prime contractor at-least one such similar work of value not less than Rs. xxxxxxx (80% of estimated cost of tender)NoneNone
NoneNoneNoneNoneExecuted in any one year the following minimum quantities of work (Cement Concrete - xxxx cum, Earthwork - xxxx cum, etc) (80% of peak rate of construction)NoneNone
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid Electrical License for executing building electrificatio works and should have executed similar electrical works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid license for executing water supply / sanitary engineering works and should have executed similar works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneOwning the following key and critical equipment for this work (xxxx, xxxx, xxxx)NoneNone
NoneNoneNoneNoneLiquid assets and /or availability of credit facilities of no less than Rs. xxxxxx Lakhs (estimated cash flow for 3 months of peak construction period)NoneNone
NoneNoneNoneNoneTotal value of civl engineering works executed and payments received in the last five years (year-wise)NoneNone
NoneNoneNoneNoneList of existing commitments and ongoing worksNoneNone
NoneNoneNoneNoneList of works for which tenders already submittedNoneNone
NoneNoneNoneNoneBanker Details for referenceNoneNone
NoneNoneNoneNoneConstruction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneReports on the financial standing of the tenderer, such as profit and loss statements and auditor’s reports for the last five yearsNoneNone
NoneNoneNoneNoneQualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneList of Financial Resources with CertificatesNoneNone
NoneNoneNoneNoneTo qualify for award of this contract , each tenderer in its name should have in the last five years achieved in at least two financial years a minimum financial turnover (In all classes of civil engineering construction works only)Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNoneScanned Copy of documentary proof for having executed similar nature of work not less than 50% of tender amount as defined in Government order No.FD 480 EXP-12/2014,Bangalore dated:19.07.2014Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneScanned copy of Pre-qualification letter issued by Karnataka Housing Board.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Scanned copy of Pre-qualification letter issued by Karnataka Housing Board.
NoneNoneNoneNoneAs per Tender Documents KW-4 clause 3.3 key & critical equipments available.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- As per Tender Documents KW-4 clause 3.3 key & critical equipments available.
NoneNoneNoneNoneExecuted in any one Financial year, the minimum quantities of work as mentioned in tender documentCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Executed in any one Financial year, the minimum quantities of work as mentioned in tender document
NoneNoneNoneNoneRequired valid electrical license for executing similar nature of work as per tender documentCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Required valid electrical license for executing similar nature of work as per tender document
NoneNoneNoneNoneThe Tenderer should have executed similar water supply/sanitary engineering works as per tender documentCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- The Tenderer should have executed similar water supply/sanitary engineering works as per tender document
NoneNoneNoneNoneIncome Tax returns & PANFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneITR Filed Copy (Mentioning PAN)
NoneNoneNoneNoneGST Registration CertificateFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneGST Registration
NoneNoneNoneNoneScanned copy of latest GST clearance certificate.Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Scanned copy of latest GST clearance certificate.
NoneNoneNoneNoneScanned copy of Credit lines/ letter of credit /Bankers certificate for at least 20% of amount put to tender in the current financial year on the name of work put to tender.Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneLine of Credit
NoneNoneNoneNoneAssessed Available Bid Capacity as per tender documentFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Assessed Available Bid Capacity as per tender document
NoneNoneNoneNoneCovering letter.OthersCovering letter.
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Covering letter.
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Annual Turnover CertificateTrueTechnical Bid
Company Registration CertificateFalseTechnical Bid
Reserved Category CertificateFalseTechnical Bid
Small Scale Industries CertificateFalseTechnical Bid
Work done certificateTrueTechnical Bid
key and critical equipment LISTTrueTechnical Bid
Income Tax returns & PAN no.TrueTechnical Bid
Pre-qualification certificate issued by KHBTrueTechnical Bid
GST clearance certificateTrueTechnical Bid
Credit lines/ letter of credit/Bankers certificateTrueTechnical Bid
Assessed available tender capacity calculationTrueTechnical Bid
Electrical licenseTrueTechnical Bid
Work done certificate with quantitiesTrueTechnical Bid