| 1718697033000 | 0 | None | None | Buildings | CONSTRUCTION OF RAITHA SIRI AGRI MALL BUILDING AT KERGAL | 82498265.89 | | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
|---|
| 3300572 | 115060 | None | code01 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work - In all kinds of soils Depth upto 3 m (S.R.I.No. 1.14.1, P.8, Vol-1 as per PWD SR for the Year 2023-24) | Cum | 141.54 | 141.54 | 3181.0 | False | None | None | False | None | False | 450238.74 | 0 | | 3300573 | 115060 | None | code02 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work - In all kinds of soils Depth 3 m to 6 m (S.R.I.No. 1.14.2, P.8, Vol-1 as per PWD SR for the Year 2023-24) | Cum | 166.23 | 166.23 | 175.0 | False | None | None | False | None | False | 29090.25 | 0 | | 3300574 | 115060 | None | code03 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. (S.R.I.No. 2.1.2, P.15, Vol-1 as per PWD SR for the Year 2023-24) | Cum | 7485.54 | 7485.54 | 24.0 | False | None | None | False | None | False | 179652.96 | 0 | | 3300575 | 115060 | None | code04 | Providing and Filling in foundation with granite / trap broken metal 100mm. And down size & with approved sand including hand packing, ramming, watering, including cost of all materials and labour with all lead and lift complete as per specifications.- 230mm thick (S.R.I.No. 1.23, P.11, Vol-1 as per PWD SR for the Year 2023-24) | Cum | 3544.53 | 3544.53 | 53.0 | False | None | None | False | None | False | 187860.09 | 0 | | 3300576 | 115060 | None | code05 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. - Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates (S.R.I.No. 2.1.2, P.15, Vol-1 as per PWD SR for the Year 2023-24) | Cum | 7485.54 | 7485.54 | 278.0 | False | None | None | False | None | False | 2080980.12 | 0 | | 3300577 | 115060 | None | code06 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. - Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates (S.R.I.No. 2.1.4, P.15, Vol-1 as per PWD SR for the Year 2023-24) Lower Ground floor | Cum | 8216.39 | 8216.39 | 2.0 | False | None | None | False | None | False | 16432.78 | 0 | | 3300578 | 115060 | None | code07 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. - Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates (S.R.I.No. 2.1.4, P.15, Vol-1 as per PWD SR for the Year 2023-24) First floor | Cum | 8298.55 | 8298.55 | 3.0 | False | None | None | False | None | False | 24895.65 | 0 | | 3300579 | 115060 | None | code08 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. - Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates (S.R.I.No. 2.1.4, P.15, Vol-1 as per PWD SR for the Year 2023-24) Second floor | Cum | 8380.71 | 8380.71 | 3.0 | False | None | None | False | None | False | 25142.13 | 0 | | 3300580 | 115060 | None | code09 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. - Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates (S.R.I.No. 2.1.4, P.15, Vol-1 as per PWD SR for the Year 2023-24) Third floor | Cum | 8462.88 | 8462.88 | 3.0 | False | None | None | False | None | False | 25388.64 | 0 | | 3300581 | 115060 | None | code10 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:2:4 Using 20 mm nominal size graded crushed coarse aggregates (S.R.I.No. 2.1.6, P.15, Vol-1 as per PWD SR for the Year 2023-24) | Cum | 8250.75 | 8250.75 | 8.0 | False | None | None | False | None | False | 66006.0 | 0 | | 3300582 | 115060 | None | code11 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (S.R.I.No.2.5.2, P.16, Vol-1 as per PWD SR for the Year 2023-24) Lintel works Lower Ground Floor | Cum | 14469.94 | 14469.94 | 9.0 | False | None | None | False | None | False | 130229.46 | 0 | | 3300583 | 115060 | None | code12 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (S.R.I.No.2.5.2, P.16, Vol-1 as per PWD SR for the Year 2023-24) Lintel works Ground Floor | Cum | 14469.94 | 14469.94 | 3.0 | False | None | None | False | None | False | 43409.82 | 0 | | 3300584 | 115060 | None | code13 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (S.R.I.No.2.5.2, P.16, Vol-1 as per PWD SR for the Year 2023-24) Lintel works First Floor | Cum | 14614.63 | 14614.63 | 3.5 | False | None | None | False | None | False | 51151.205 | 0 | | 3300585 | 115060 | None | code14 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (S.R.I.No.2.5.2, P.16, Vol-1 as per PWD SR for the Year 2023-24) Lintel works Second Floor | Cum | 14759.33 | 14759.33 | 3.5 | False | None | None | False | None | False | 51657.655 | 0 | | 3300586 | 115060 | None | code15 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (S.R.I.No.2.5.2, P.16, Vol-1 as per PWD SR for the Year 2023-24) Lintel works Third Floor | Cum | 14904.04 | 14904.04 | 3.5 | False | None | None | False | None | False | 52164.14 | 0 | | 3300587 | 115060 | None | code16 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (S.R.I.No.2.5.2, P.16, Vol-1 as per PWD SR for the Year 2023-24) Lintel works Terrace Floor | Cum | 15048.73 | 15048.73 | 0.3 | False | None | None | False | None | False | 4514.619 | 0 | | 3300588 | 115060 | None | code17 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (S.R.I.No.2.5.2, P.16, Vol-1 as per PWD SR for the Year 2023-24) Shade Ground Floor | Cum | 13113.38 | 13113.38 | 0.1 | False | None | None | False | None | False | 1311.338 | 0 | | 3300589 | 115060 | None | code18 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (S.R.I.No.2.5.2, P.16, Vol-1 as per PWD SR for the Year 2023-24) Shade First Floor | Cum | 13244.51 | 13244.51 | 3.0 | False | None | None | False | None | False | 39733.53 | 0 | | 3300590 | 115060 | None | code19 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (S.R.I.No.2.5.2, P.16, Vol-1 as per PWD SR for the Year 2023-24) Shade Second Floor | Cum | 13375.64 | 13375.64 | 3.0 | False | None | None | False | None | False | 40126.92 | 0 | | 3300591 | 115060 | None | code20 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (S.R.I.No.2.5.2, P.16, Vol-1 as per PWD SR for the Year 2023-24) Shade Third Floor | Cum | 13506.78 | 13506.78 | 3.0 | False | None | None | False | None | False | 40520.34 | 0 | | 3300592 | 115060 | None | code21 | Demolition works: Pile Chipping and levelling works M40 grade by mechanical means using Bosch/ Hilti machines only including cost of disposing off the material, labour, machinery charges etc ( breaking through compresssors or tractor mounted machines not allowed )complete , 600mm and 750mm dia piles- upto 1.2m deep | Cum | 3540.0 | 3540.0 | 44.0 | False | None | None | False | None | False | 155760.0 | 0 | | 3300593 | 115060 | None | code22 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality,testing of cubes 6 no's for every 36 Cum of concrete , all labour charges, shuttering and De Shuttering Charges , Cleaning the area after de shuttering , scaffolding charges, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (S.R.I.No.2.4.4, P.16, Vol-1 as per PWD SR for the Year 2023-24) Pile Cap | Cum | 9623.04 | 9623.04 | 184.0 | False | None | None | False | None | False | 1770639.36 | 0 | | 3300594 | 115060 | None | code23 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (S.R.I.No.2.4.3, P.16, Vol-1 as per PWD SR for the Year 2023-24) Lower Ground Floor Footing | Cum | 9043.56 | 9043.56 | 146.0 | False | None | None | False | None | False | 1320359.76 | 0 | | 3300595 | 115060 | None | code24 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (S.R.I.No.2.4.3, P.16, Vol-1 as per PWD SR for the Year 2023-24) Lower Ground Floor Raft Beam | Cum | 9043.56 | 9043.56 | 1.0 | False | None | None | False | None | False | 9043.56 | 0 | | 3300596 | 115060 | None | code25 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (S.R.I.No.2.4.3, P.16, Vol-1 as per PWD SR for the Year 2023-24) Lower Ground Floor Plinth Beam | Cum | 12560.49 | 12560.49 | 27.0 | False | None | None | False | None | False | 339133.23 | 0 | | 3300597 | 115060 | None | code26 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (S.R.I.No.2.4.3, P.16, Vol-1 as per PWD SR for the Year 2023-24) Lower Ground Floor Pedastal | Cum | 14235.21 | 14235.21 | 25.0 | False | None | None | False | None | False | 355880.25 | 0 | | 3300598 | 115060 | None | code27 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 4.00m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, testing of cubes 6 no's for every 36 Cum of concrete , all albour charges, shuttering and DE SHUTTERING CHARGES , Cleaning the rea after de shuttering , scaffolding and dismantling charges,cleaning of all slabs soon after the evry floor de shutterings, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (S.R.I.No.2.5.2, P.16, Vol-1 as per PWD SR for the Year 2023-24) Ground Floor Column | Cum | 15374.3 | 15374.3 | 57.0 | False | None | None | False | None | False | 876335.1 | 0 | | 3300599 | 115060 | None | code28 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 4.00m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, testing of cubes 6 no's for every 36 Cum of concrete , all albour charges, shuttering and DE SHUTTERING CHARGES , Cleaning the rea after de shuttering , scaffolding and dismantling charges,cleaning of all slabs soon after the evry floor de shutterings, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (S.R.I.No.2.5.2, P.16, Vol-1 as per PWD SR for the Year 2023-24) Ground Floor Roof Beam | Cum | 14469.94 | 14469.94 | 87.0 | False | None | None | False | None | False | 1258884.78 | 0 | | 3300600 | 115060 | None | code29 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 4.00m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, testing of cubes 6 no's for every 36 Cum of concrete , all albour charges, shuttering and DE SHUTTERING CHARGES , Cleaning the rea after de shuttering , scaffolding and dismantling charges,cleaning of all slabs soon after the evry floor de shutterings, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (S.R.I.No.2.5.2, P.16, Vol-1 as per PWD SR for the Year 2023-24) Ground Floor Slab (including providing and laying 150 micron Low Density Polyethylene (LDPE) sheet confirming to IS 3395 : 1997 below concrete slab including all materials and labour complete.) | Cum | 13565.56 | 13565.56 | 243.0 | False | None | None | False | None | False | 3296431.08 | 0 | | 3300601 | 115060 | None | code30 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 4.00m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, testing of cubes 6 no's for every 36 Cum of concrete , all albour charges, shuttering and DE SHUTTERING CHARGES , Cleaning the rea after de shuttering , scaffolding and dismantling charges,cleaning of all slabs soon after the evry floor de shutterings, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (S.R.I.No.2.5.2, P.16, Vol-1 as per PWD SR for the Year 2023-24) Ground Floor Staircase | Cum | 13565.56 | 13565.56 | 4.0 | False | None | None | False | None | False | 54262.24 | 0 | | 3300602 | 115060 | None | code31 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 4.00m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, testing of cubes 6 no's for every 36 Cum of concrete , all albour charges, shuttering and DE SHUTTERING CHARGES , Cleaning the rea after de shuttering , scaffolding and dismantling charges,cleaning of all slabs soon after the evry floor de shutterings, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (S.R.I.No.2.5.2, P.16, Vol-1 as per PWD SR for the Year 2023-24) Ground Floor Retaining wall-double Shuttering | Cum | 9948.08 | 9948.08 | 98.0 | False | None | None | False | None | False | 974911.84 | 0 | | 3300603 | 115060 | None | code32 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 4.00m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, testing of cubes 6 no's for every 36 Cum of concrete , all albour charges, shuttering and DE SHUTTERING CHARGES , Cleaning the rea after de shuttering , scaffolding and dismantling charges,cleaning of all slabs soon after the evry floor de shutterings, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (S.R.I.No.2.5.2, P.16, Vol-1 as per PWD SR for the Year 2023-24) Ground Floor Column | Cum | 15374.3 | 15374.3 | 41.0 | False | None | None | False | None | False | 630346.3 | 0 | | 3300604 | 115060 | None | code33 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 4.00m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, testing of cubes 6 no's for every 36 Cum of concrete , all albour charges, shuttering and DE SHUTTERING CHARGES , Cleaning the rea after de shuttering , scaffolding and dismantling charges,cleaning of all slabs soon after the evry floor de shutterings, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (S.R.I.No.2.5.2, P.16, Vol-1 as per PWD SR for the Year 2023-24) Ground Floor Roof Beam | Cum | 14469.94 | 14469.94 | 67.0 | False | None | None | False | None | False | 969485.98 | 0 | | 3300605 | 115060 | None | code34 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 4.00m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, testing of cubes 6 no's for every 36 Cum of concrete , all albour charges, shuttering and DE SHUTTERING CHARGES , Cleaning the rea after de shuttering , scaffolding and dismantling charges,cleaning of all slabs soon after the evry floor de shutterings, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (S.R.I.No.2.5.2, P.16, Vol-1 as per PWD SR for the Year 2023-24) Ground Floor Slab (including providing and laying 150 micron Low Density Polyethylene (LDPE) sheet confirming to IS 3395 : 1997 below concrete slab including all materials and labour complete.) | Cum | 13565.56 | 13565.56 | 115.0 | False | None | None | False | None | False | 1560039.4 | 0 | | 3300606 | 115060 | None | code35 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 4.00m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, testing of cubes 6 no's for every 36 Cum of concrete , all albour charges, shuttering and DE SHUTTERING CHARGES , Cleaning the rea after de shuttering , scaffolding and dismantling charges,cleaning of all slabs soon after the evry floor de shutterings, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (S.R.I.No.2.5.2, P.16, Vol-1 as per PWD SR for the Year 2023-24) Ground Floor Drop gutter wall | Cum | 13113.38 | 13113.38 | 6.5 | False | None | None | False | None | False | 85236.97 | 0 | | 3300607 | 115060 | None | code36 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 4.00m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, testing of cubes 6 no's for every 36 Cum of concrete , all albour charges, shuttering and DE SHUTTERING CHARGES , Cleaning the rea after de shuttering , scaffolding and dismantling charges,cleaning of all slabs soon after the evry floor de shutterings, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (S.R.I.No.2.5.2, P.16, Vol-1 as per PWD SR for the Year 2023-24) Ground Floor Staircase | Cum | 13565.56 | 13565.56 | 9.0 | False | None | None | False | None | False | 122090.04 | 0 | | 3300608 | 115060 | None | code37 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 4.00m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, testing of cubes 6 no's for every 36 Cum of concrete , all albour charges, shuttering and DE SHUTTERING CHARGES , Cleaning the rea after de shuttering , scaffolding and dismantling charges,cleaning of all slabs soon after the evry floor de shutterings, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (S.R.I.No.2.5.2, P.16, Vol-1 as per PWD SR for the Year 2023-24) First Floor Column | Cum | 15528.04 | 15528.04 | 41.0 | False | None | None | False | None | False | 636649.64 | 0 | | 3300609 | 115060 | None | code38 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 4.00m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, testing of cubes 6 no's for every 36 Cum of concrete , all albour charges, shuttering and DE SHUTTERING CHARGES , Cleaning the rea after de shuttering , scaffolding and dismantling charges,cleaning of all slabs soon after the evry floor de shutterings, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (S.R.I.No.2.5.2, P.16, Vol-1 as per PWD SR for the Year 2023-24) First Floor Roof Beam | Cum | 14614.63 | 14614.63 | 54.0 | False | None | None | False | None | False | 789190.02 | 0 | | 3300610 | 115060 | None | code39 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 4.00m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, testing of cubes 6 no's for every 36 Cum of concrete , all albour charges, shuttering and DE SHUTTERING CHARGES , Cleaning the rea after de shuttering , scaffolding and dismantling charges,cleaning of all slabs soon after the evry floor de shutterings, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (S.R.I.No.2.5.2, P.16, Vol-1 as per PWD SR for the Year 2023-24) First Floor Slab (including providing and laying 150 micron Low Density Polyethylene (LDPE) sheet confirming to IS 3395 : 1997 below concrete slab including all materials and labour complete.) | Cum | 13701.22 | 13701.22 | 107.0 | False | None | None | False | None | False | 1466030.54 | 0 | | 3300611 | 115060 | None | code40 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 4.00m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, testing of cubes 6 no's for every 36 Cum of concrete , all albour charges, shuttering and DE SHUTTERING CHARGES , Cleaning the rea after de shuttering , scaffolding and dismantling charges,cleaning of all slabs soon after the evry floor de shutterings, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (S.R.I.No.2.5.2, P.16, Vol-1 as per PWD SR for the Year 2023-24) First Floor Staircase | Cum | 13701.22 | 13701.22 | 9.0 | False | None | None | False | None | False | 123310.98 | 0 | | 3300612 | 115060 | None | code41 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 4.00m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, testing of cubes 6 no's for every 36 Cum of concrete , all albour charges, shuttering and DE SHUTTERING CHARGES , Cleaning the rea after de shuttering , scaffolding and dismantling charges,cleaning of all slabs soon after the evry floor de shutterings, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (S.R.I.No.2.5.2, P.16, Vol-1 as per PWD SR for the Year 2023-24) Second Floor Column | Cum | 15681.79 | 15681.79 | 41.0 | False | None | None | False | None | False | 642953.39 | 0 | | 3300613 | 115060 | None | code42 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 4.00m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, testing of cubes 6 no's for every 36 Cum of concrete , all albour charges, shuttering and DE SHUTTERING CHARGES , Cleaning the rea after de shuttering , scaffolding and dismantling charges,cleaning of all slabs soon after the evry floor de shutterings, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (S.R.I.No.2.5.2, P.16, Vol-1 as per PWD SR for the Year 2023-24) Second Floor Roof Beam | Cum | 14759.33 | 14759.33 | 54.0 | False | None | None | False | None | False | 797003.82 | 0 | | 3300614 | 115060 | None | code43 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 4.00m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, testing of cubes 6 no's for every 36 Cum of concrete , all albour charges, shuttering and DE SHUTTERING CHARGES , Cleaning the rea after de shuttering , scaffolding and dismantling charges,cleaning of all slabs soon after the evry floor de shutterings, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (S.R.I.No.2.5.2, P.16, Vol-1 as per PWD SR for the Year 2023-24) Second Floor Slab (including providing and laying 150 micron Low Density Polyethylene (LDPE) sheet confirming to IS 3395 : 1997 below concrete slab including all materials and labour complete.) | Cum | 13836.87 | 13836.87 | 108.0 | False | None | None | False | None | False | 1494381.96 | 0 | | 3300615 | 115060 | None | code44 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 4.00m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, testing of cubes 6 no's for every 36 Cum of concrete , all albour charges, shuttering and DE SHUTTERING CHARGES , Cleaning the rea after de shuttering , scaffolding and dismantling charges,cleaning of all slabs soon after the evry floor de shutterings, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (S.R.I.No.2.5.2, P.16, Vol-1 as per PWD SR for the Year 2023-24) Second Floor Staircase | Cum | 13836.87 | 13836.87 | 13.0 | False | None | None | False | None | False | 179879.31 | 0 | | 3300616 | 115060 | None | code45 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 4.00m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, testing of cubes 6 no's for every 36 Cum of concrete , all albour charges, shuttering and DE SHUTTERING CHARGES , Cleaning the rea after de shuttering , scaffolding and dismantling charges,cleaning of all slabs soon after the evry floor de shutterings, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (S.R.I.No.2.5.2, P.16, Vol-1 as per PWD SR for the Year 2023-24) Third Floor Column | Cum | 15835.53 | 15835.53 | 31.5 | False | None | None | False | None | False | 498819.195 | 0 | | 3300617 | 115060 | None | code46 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 4.00m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, testing of cubes 6 no's for every 36 Cum of concrete , all albour charges, shuttering and DE SHUTTERING CHARGES , Cleaning the rea after de shuttering , scaffolding and dismantling charges,cleaning of all slabs soon after the evry floor de shutterings, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (S.R.I.No.2.5.2, P.16, Vol-1 as per PWD SR for the Year 2023-24) Third Floor Roof Beam | Cum | 14904.04 | 14904.04 | 9.5 | False | None | None | False | None | False | 141588.38 | 0 | | 3300618 | 115060 | None | code47 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 4.00m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, testing of cubes 6 no's for every 36 Cum of concrete , all albour charges, shuttering and DE SHUTTERING CHARGES , Cleaning the rea after de shuttering , scaffolding and dismantling charges,cleaning of all slabs soon after the evry floor de shutterings, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (S.R.I.No.2.5.2, P.16, Vol-1 as per PWD SR for the Year 2023-24) Third Floor Slab (including providing and laying 150 micron Low Density Polyethylene (LDPE) sheet confirming to IS 3395 : 1997 below concrete slab including all materials and labour complete.) | Cum | 13972.53 | 13972.53 | 24.0 | False | None | None | False | None | False | 335340.72 | 0 | | 3300619 | 115060 | None | code48 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 4.00m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, testing of cubes 6 no's for every 36 Cum of concrete , all albour charges, shuttering and DE SHUTTERING CHARGES , Cleaning the rea after de shuttering , scaffolding and dismantling charges,cleaning of all slabs soon after the evry floor de shutterings, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (S.R.I.No.2.5.2, P.16, Vol-1 as per PWD SR for the Year 2023-24) Third Floor Drop gutter wall | Cum | 13972.53 | 13972.53 | 5.9982 | False | None | None | False | None | False | 83810.029446 | 0 | | 3300620 | 115060 | None | code49 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 4.00m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, testing of cubes 6 no's for every 36 Cum of concrete , all albour charges, shuttering and DE SHUTTERING CHARGES , Cleaning the rea after de shuttering , scaffolding and dismantling charges,cleaning of all slabs soon after the evry floor de shutterings, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (S.R.I.No.2.5.2, P.16, Vol-1 as per PWD SR for the Year 2023-24) Third Floor Staircase | Cum | 13972.53 | 13972.53 | 4.0 | False | None | None | False | None | False | 55890.12 | 0 | | 3300621 | 115060 | None | code50 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 4.00m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, testing of cubes 6 no's for every 36 Cum of concrete , all albour charges, shuttering and DE SHUTTERING CHARGES , Cleaning the rea after de shuttering , scaffolding and dismantling charges,cleaning of all slabs soon after the evry floor de shutterings, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (S.R.I.No.2.5.2, P.16, Vol-1 as per PWD SR for the Year 2023-24) Terrace Floor Column | Cum | 15989.27 | 15989.27 | 7.5 | False | None | None | False | None | False | 119919.525 | 0 | | 3300622 | 115060 | None | code51 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 4.00m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, testing of cubes 6 no's for every 36 Cum of concrete , all albour charges, shuttering and DE SHUTTERING CHARGES , Cleaning the rea after de shuttering , scaffolding and dismantling charges,cleaning of all slabs soon after the evry floor de shutterings, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (S.R.I.No.2.5.2, P.16, Vol-1 as per PWD SR for the Year 2023-24) Terrace Floor Roof Beam | Cum | 15048.73 | 15048.73 | 19.5 | False | None | None | False | None | False | 293450.235 | 0 | | 3300623 | 115060 | None | code52 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 4.00m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, testing of cubes 6 no's for every 36 Cum of concrete , all albour charges, shuttering and DE SHUTTERING CHARGES , Cleaning the rea after de shuttering , scaffolding and dismantling charges,cleaning of all slabs soon after the evry floor de shutterings, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (S.R.I.No.2.5.2, P.16, Vol-1 as per PWD SR for the Year 2023-24) Terrace Floor Slab (including providing and laying 150 micron Low Density Polyethylene (LDPE) sheet confirming to IS 3395 : 1997 below concrete slab including all materials and labour complete.) | Cum | 14108.19 | 14108.19 | 27.5 | False | None | None | False | None | False | 387975.225 | 0 | | 3300624 | 115060 | None | code53 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 4.00m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, testing of cubes 6 no's for every 36 Cum of concrete , all albour charges, shuttering and DE SHUTTERING CHARGES , Cleaning the rea after de shuttering , scaffolding and dismantling charges,cleaning of all slabs soon after the evry floor de shutterings, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (S.R.I.No.2.5.2, P.16, Vol-1 as per PWD SR for the Year 2023-24) Terrace Floor RCC wall | Cum | 10346.0 | 10346.0 | 7.0 | False | None | None | False | None | False | 72422.0 | 0 | | 3300625 | 115060 | None | code54 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification (Only Tata, Jindal Panther and JSW Make steel are allowed) (S.R.I.No.2.11 a, P.18, Vol-1 as per PWD SR for the Year 2023-24) Lower Ground Floor | Tonne | 118226.37 | 118226.37 | 85.0 | False | None | None | False | None | False | 10049241.45 | 0 | | 3300626 | 115060 | None | code55 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification (Only Tata, Jindal Panther and JSW Make steel are allowed) (S.R.I.No.2.11 a, P.18, Vol-1 as per PWD SR for the Year 2023-24) Ground Floor | Tonne | 118226.37 | 118226.37 | 31.3 | False | None | None | False | None | False | 3700485.381 | 0 | | 3300627 | 115060 | None | code56 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification (Only Tata, Jindal Panther and JSW Make steel are allowed) (S.R.I.No.2.11 a, P.18, Vol-1 as per PWD SR for the Year 2023-24) First Floor | Tonne | 119408.64 | 119408.64 | 28.1 | False | None | None | False | None | False | 3355382.784 | 0 | | 3300628 | 115060 | None | code57 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification (Only Tata, Jindal Panther and JSW Make steel are allowed) (S.R.I.No.2.11 a, P.18, Vol-1 as per PWD SR for the Year 2023-24) Second Floor | Tonne | 120590.9 | 120590.9 | 28.8 | False | None | None | False | None | False | 3473017.92 | 0 | | 3300629 | 115060 | None | code58 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification (Only Tata, Jindal Panther and JSW Make steel are allowed) (S.R.I.No.2.11 a, P.18, Vol-1 as per PWD SR for the Year 2023-24) Third Floor | Tonne | 121773.17 | 121773.17 | 10.9 | False | None | None | False | None | False | 1327327.553 | 0 | | 3300630 | 115060 | None | code59 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification (Only Tata, Jindal Panther and JSW Make steel are allowed) (S.R.I.No.2.11 a, P.18, Vol-1 as per PWD SR for the Year 2023-24) Terrace Floor | Tonne | 122955.42 | 122955.42 | 7.7 | False | None | None | False | None | False | 946756.734 | 0 | | 3300631 | 115060 | None | code60 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. (S.R.I.No.1.9, P.7, Vol-1 as per PWD SR for the Year 2023-24) | Cum | 351.55 | 351.55 | 872.0 | False | None | None | False | None | False | 306551.6 | 0 | | 3300632 | 115060 | None | code61 | Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications. Sunken Fiiling (S.R.I.No.7.18, P.23, Vol-2 as per PWD SR for the Year 2023-24) First Floor | Cum | 2692.32 | 2692.32 | 7.0 | False | None | None | False | None | False | 18846.24 | 0 | | 3300633 | 115060 | None | code62 | Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications. Sunken Fiiling (S.R.I.No.7.18, P.23, Vol-2 as per PWD SR for the Year 2023-24) Second Floor | Cum | 2718.98 | 2718.98 | 7.0 | False | None | None | False | None | False | 19032.86 | 0 | | 3300634 | 115060 | None | code63 | Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications. Sunken Fiiling (S.R.I.No.7.18, P.23, Vol-2 as per PWD SR for the Year 2023-24) Third Floor | Cum | 2745.64 | 2745.64 | 7.0 | False | None | None | False | None | False | 19219.48 | 0 | | 3300635 | 115060 | None | code64 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) (S.R.I.No.5.4, P.9, Vol-2 as per PWD SR for the Year 2023-24) | Cum | 8443.7 | 8443.7 | 3.0 | False | None | None | False | None | False | 25331.1 | 0 | | 3300636 | 115060 | None | code65 | Providing and constructing laterite size stone masonry including cost and conveyance of all materials curing etc complete as per specification I.S. 3620/1979 having compressive strength not less than 3.5 N/mm2 for saturated dry samples - For Super structure in CM 1:6. (S.R.I.No.5.7, P.9, Vol-2 as per PWD SR for the Year 2023-24) Lower Ground Floor | Cum | 8927.41 | 8927.41 | 17.5 | False | None | None | False | None | False | 156229.675 | 0 | | 3300637 | 115060 | None | code66 | Providing and constructing laterite size stone masonry including cost and conveyance of all materials curing etc complete as per specification I.S. 3620/1979 having compressive strength not less than 3.5 N/mm2 for saturated dry samples - For Super structure in CM 1:6. (S.R.I.No.5.7, P.9, Vol-2 as per PWD SR for the Year 2023-24) Ground Floor | Cum | 8927.41 | 8927.41 | 18.5 | False | None | None | False | None | False | 165157.085 | 0 | | 3300638 | 115060 | None | code67 | Providing and constructing laterite size stone masonry including cost and conveyance of all materials curing etc complete as per specification I.S. 3620/1979 having compressive strength not less than 3.5 N/mm2 for saturated dry samples - For Super structure in CM 1:6. (S.R.I.No.5.7, P.9, Vol-2 as per PWD SR for the Year 2023-24) First Floor | Cum | 9016.69 | 9016.69 | 18.5 | False | None | None | False | None | False | 166808.765 | 0 | | 3300639 | 115060 | None | code68 | Providing and constructing laterite size stone masonry including cost and conveyance of all materials curing etc complete as per specification I.S. 3620/1979 having compressive strength not less than 3.5 N/mm2 for saturated dry samples - For Super structure in CM 1:6. (S.R.I.No.5.7, P.9, Vol-2 as per PWD SR for the Year 2023-24) Second Floor | Cum | 9105.95 | 9105.95 | 18.5 | False | None | None | False | None | False | 168460.075 | 0 | | 3300640 | 115060 | None | code69 | Providing and constructing laterite size stone masonry including cost and conveyance of all materials curing etc complete as per specification I.S. 3620/1979 having compressive strength not less than 3.5 N/mm2 for saturated dry samples - For Super structure in CM 1:6. (S.R.I.No.5.7, P.9, Vol-2 as per PWD SR for the Year 2023-24) Third Floor | Cum | 9195.23 | 9195.23 | 16.5 | False | None | None | False | None | False | 151721.295 | 0 | | 3300641 | 115060 | None | code70 | Providing and constructing laterite size stone masonry including cost and conveyance of all materials curing etc complete as per specification I.S. 3620/1979 having compressive strength not less than 3.5 N/mm2 for saturated dry samples - For Super structure in CM 1:6. (S.R.I.No.5.7, P.9, Vol-2 as per PWD SR for the Year 2023-24) Terrace Floor | Cum | 9284.5 | 9284.5 | 9.5 | False | None | None | False | None | False | 88202.75 | 0 | | 3300642 | 115060 | None | code71 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. (S.R.I.No.6.32, P.17, Vol-2 as per PWD SR for the Year 2023-24) Lower Ground Floor | Sqm | 1731.3 | 1731.3 | 473.0 | False | None | None | False | None | False | 818904.9 | 0 | | 3300643 | 115060 | None | code72 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. (S.R.I.No.6.32, P.17, Vol-2 as per PWD SR for the Year 2023-24) Ground Floor | Sqm | 1731.3 | 1731.3 | 422.0 | False | None | None | False | None | False | 730608.6 | 0 | | 3300644 | 115060 | None | code73 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. (S.R.I.No.6.32, P.17, Vol-2 as per PWD SR for the Year 2023-24) First Floor | Sqm | 1748.61 | 1748.61 | 488.0 | False | None | None | False | None | False | 853321.68 | 0 | | 3300645 | 115060 | None | code74 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. (S.R.I.No.6.32, P.17, Vol-2 as per PWD SR for the Year 2023-24) Second Floor | Sqm | 1765.92 | 1765.92 | 431.5 | False | None | None | False | None | False | 761994.48 | 0 | | 3300646 | 115060 | None | code75 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. (S.R.I.No.6.32, P.17, Vol-2 as per PWD SR for the Year 2023-24) Third Floor | Sqm | 1783.24 | 1783.24 | 286.0 | False | None | None | False | None | False | 510006.64 | 0 | | 3300647 | 115060 | None | code76 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. (S.R.I.No.6.32, P.17, Vol-2 as per PWD SR for the Year 2023-24) Terrace Floor | Sqm | 1800.55 | 1800.55 | 111.5 | False | None | None | False | None | False | 200761.325 | 0 | | 3300648 | 115060 | None | code77 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. (S.R.I.No.6.34, P.17, Vol-2 as per PWD SR for the Year 2023-24) First Floor | Sqm | 1473.63 | 1473.63 | 67.0 | False | None | None | False | None | False | 98733.21 | 0 | | 3300649 | 115060 | None | code78 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. (S.R.I.No.6.34, P.17, Vol-2 as per PWD SR for the Year 2023-24) Second Floor | Sqm | 1488.23 | 1488.23 | 67.0 | False | None | None | False | None | False | 99711.41 | 0 | | 3300650 | 115060 | None | code79 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. (S.R.I.No.6.34, P.17, Vol-2 as per PWD SR for the Year 2023-24) Third Floor | Sqm | 1502.81 | 1502.81 | 67.0 | False | None | None | False | None | False | 100688.27 | 0 | | 3300651 | 115060 | None | code80 | Polyurethane based Single Component for New Surface Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6 kg/m2 to achieve final DFT (Dry Film Thickness) of 1mm including prime coat of epoxy primer @150 g/m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification. (S.R.I.No.15.1, P.149, Vol-2 as per PWD SR for the Year 2023-24) First Floor- Toilet | Sqm | 1089.39 | 1089.39 | 35.5 | False | None | None | False | None | False | 38673.345 | 0 | | 3300652 | 115060 | None | code81 | Polyurethane based Single Component for New Surface Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6 kg/m2 to achieve final DFT (Dry Film Thickness) of 1mm including prime coat of epoxy primer @150 g/m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification. (S.R.I.No.15.1, P.149, Vol-2 as per PWD SR for the Year 2023-24) Second Floor- Toilet | Sqm | 1099.03 | 1099.03 | 35.5 | False | None | None | False | None | False | 39015.565 | 0 | | 3300653 | 115060 | None | code82 | Polyurethane based Single Component for New Surface Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6 kg/m2 to achieve final DFT (Dry Film Thickness) of 1mm including prime coat of epoxy primer @150 g/m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification. (S.R.I.No.15.1, P.149, Vol-2 as per PWD SR for the Year 2023-24) Third Floor- Toilet | Sqm | 1108.67 | 1108.67 | 35.5 | False | None | None | False | None | False | 39357.785 | 0 | | 3300654 | 115060 | None | code83 | Polyurethane based Single Component for New Surface Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6 kg/m2 to achieve final DFT (Dry Film Thickness) of 1mm including prime coat of epoxy primer @150 g/m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification. (S.R.I.No.15.1, P.149, Vol-2 as per PWD SR for the Year 2023-24) Terrace Floor | Sqm | 1118.31 | 1118.31 | 181.5 | False | None | None | False | None | False | 202973.265 | 0 | | 3300655 | 115060 | None | code84 | High Density Polyethylene Membrane water proofing for Lift Pits Providing and laying water proofing treatment to the Rafts, Below grade slab, Lift pits, water retaining structures with fully bonded High Density Polyethlene Membrane (HDPE) of 1.2mm composite thickness andhaving tensile strength of greater than 25 MPa (as per ASTM D 412), elongation of greater than 500% (as per ASTM D 412), puncture resistance of greater than 1000N (as per ASTM E 154), peel adhesion to concrete greater than 1200N/m (as per ASTM D 903), hydrostatic head resistance greater than70m (as per ASTM D 5385). The system should be fully bonded to the RCC thereby conforming to IS 16471:2017 requirements of UG waterproofing structures. The membrane should be minimum 2.4m wide to reduce the number of joints with minimum 75mm factory made selvedge’s and comprising of an HDPE layer and a pressure sensitive adhesive layer which is covered by a weather proof protective and trafficable granular layer to protect self-adhesive polymer layer, etc, including surface preparation completely as per specification. (S.R.I.No.15.5, P.150, Vol-2 as per PWD SR for the Year 2023-24) Ground Floor- Lift Pits | Sqm | 799.57 | 799.57 | 44.0 | False | None | None | False | None | False | 35181.08 | 0 | | 3300656 | 115060 | None | code85 | Food Graded Water Proofing Membrane For Water Tanks Providing and laying water proofing treatment to the Water tanks & Liquid Retaining structures with two component acrylic polymer modified cementitious waterproofing membrane with minimum elongation of 50% applied @ 1.5 kg/m2 for internal side waterproofing in two layers with waiting period of 4-6 hrs per layer and food grade epoxy coating in two coats certified by CFTRI Mysuru, including surface preparation completely as per specification. (S.R.I.No.15.6, P.150, Vol-2 as per PWD SR for the Year 2023-24) water tank | Sqm | 670.05 | 670.05 | 103.5 | False | None | None | False | None | False | 69350.175 | 0 | | 3300657 | 115060 | None | code86 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. 6" wide arpitha mesh should be provided at all the masonry rcc joints before starting the plastering works (Internal walls) (S.R.I.No.8.5.2, P.42, Vol-2 as per PWD SR for the Year 2023-24) Lower Ground Floor | Sqm | 461.24 | 461.24 | 1930.0 | False | None | None | False | None | False | 890193.2 | 0 | | 3300658 | 115060 | None | code87 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. 6" wide arpitha mesh should be provided at all the masonry rcc joints before starting the plastering works (Internal walls) (S.R.I.No.8.5.2, P.42, Vol-2 as per PWD SR for the Year 2023-24) Ground Floor | Sqm | 461.24 | 461.24 | 1189.0 | False | None | None | False | None | False | 548414.36 | 0 | | 3300659 | 115060 | None | code88 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. 6" wide arpitha mesh should be provided at all the masonry rcc joints before starting the plastering works (Internal walls) (S.R.I.No.8.5.2, P.42, Vol-2 as per PWD SR for the Year 2023-24) First Floor | Sqm | 465.85 | 465.85 | 1357.0 | False | None | None | False | None | False | 632158.45 | 0 | | 3300660 | 115060 | None | code89 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. 6" wide arpitha mesh should be provided at all the masonry rcc joints before starting the plastering works (Internal walls) (S.R.I.No.8.5.2, P.42, Vol-2 as per PWD SR for the Year 2023-24) Second Floor | Sqm | 470.47 | 470.47 | 1281.0 | False | None | None | False | None | False | 602672.07 | 0 | | 3300661 | 115060 | None | code90 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. 6" wide arpitha mesh should be provided at all the masonry rcc joints before starting the plastering works (Internal walls) (S.R.I.No.8.5.2, P.42, Vol-2 as per PWD SR for the Year 2023-24) Third Floor | Sqm | 475.08 | 475.08 | 747.0 | False | None | None | False | None | False | 354884.76 | 0 | | 3300662 | 115060 | None | code91 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. 6" wide arpitha mesh should be provided at all the masonry rcc joints before starting the plastering works (Internal walls) (S.R.I.No.8.5.2, P.42, Vol-2 as per PWD SR for the Year 2023-24) Terrace Floor | Sqm | 479.69 | 479.69 | 123.0 | False | None | None | False | None | False | 59001.87 | 0 | | 3300663 | 115060 | None | code92 | Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing, the slab should be hacked with the pointed chisel so as to get the rough surface before taking the ceiling plumb levels and approval should be taken 1 day before starting the plastering from the consultant complete as per specifications and as per directions of Engineer-in-charge. (Ceiling Plastering) (S.R.I.No.8.5.2, P.42, Vol-2 as per PWD SR for the Year 2023-24) Lower Ground Floor | Sqm | 461.24 | 461.24 | 1936.0 | False | None | None | False | None | False | 892960.64 | 0 | | 3300664 | 115060 | None | code93 | Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing, the slab should be hacked with the pointed chisel so as to get the rough surface before taking the ceiling plumb levels and approval should be taken 1 day before starting the plastering from the consultant complete as per specifications and as per directions of Engineer-in-charge. (Ceiling Plastering) (S.R.I.No.8.5.2, P.42, Vol-2 as per PWD SR for the Year 2023-24) Ground Floor | Sqm | 461.24 | 461.24 | 1226.0 | False | None | None | False | None | False | 565480.24 | 0 | | 3300665 | 115060 | None | code94 | Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing, the slab should be hacked with the pointed chisel so as to get the rough surface before taking the ceiling plumb levels and approval should be taken 1 day before starting the plastering from the consultant complete as per specifications and as per directions of Engineer-in-charge. (Ceiling Plastering) (S.R.I.No.8.5.2, P.42, Vol-2 as per PWD SR for the Year 2023-24) First Floor | Sqm | 465.85 | 465.85 | 1112.0 | False | None | None | False | None | False | 518025.2 | 0 | | 3300666 | 115060 | None | code95 | Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing, the slab should be hacked with the pointed chisel so as to get the rough surface before taking the ceiling plumb levels and approval should be taken 1 day before starting the plastering from the consultant complete as per specifications and as per directions of Engineer-in-charge. (Ceiling Plastering) (S.R.I.No.8.5.2, P.42, Vol-2 as per PWD SR for the Year 2023-24) Second Floor | Sqm | 470.47 | 470.47 | 1112.0 | False | None | None | False | None | False | 523162.64 | 0 | | 3300667 | 115060 | None | code96 | Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing, the slab should be hacked with the pointed chisel so as to get the rough surface before taking the ceiling plumb levels and approval should be taken 1 day before starting the plastering from the consultant complete as per specifications and as per directions of Engineer-in-charge. (Ceiling Plastering) (S.R.I.No.8.5.2, P.42, Vol-2 as per PWD SR for the Year 2023-24) Third Floor | Sqm | 475.08 | 475.08 | 1218.0 | False | None | None | False | None | False | 578647.44 | 0 | | 3300668 | 115060 | None | code97 | Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing, the slab should be hacked with the pointed chisel so as to get the rough surface before taking the ceiling plumb levels and approval should be taken 1 day before starting the plastering from the consultant complete as per specifications and as per directions of Engineer-in-charge. (Ceiling Plastering) (S.R.I.No.8.5.2, P.42, Vol-2 as per PWD SR for the Year 2023-24) Terrace Floor | Sqm | 479.69 | 479.69 | 34.0 | False | None | None | False | None | False | 16309.46 | 0 | | 3300669 | 115060 | None | code98 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Providing 6 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, finished with waterproofing compound of make FOSROC/ Dr Fixit/ Algiproof, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. 6" wide Arpitha make mesh should be provided at all the masonry rcc joints before starting the plastering works External Wall (S.R.I.No.8.3.2, P.41, Vol-2 as per PWD SR for the Year 2023-24) Lower Ground Floor | Sqm | 672.6 | 672.6 | 66.0 | False | None | None | False | None | False | 44391.6 | 0 | | 3300670 | 115060 | None | code99 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Providing 6 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, finished with waterproofing compound of make FOSROC/ Dr Fixit/ Algiproof, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. 6" wide Arpitha make mesh should be provided at all the masonry rcc joints before starting the plastering works External Wall (S.R.I.No.8.3.2, P.41, Vol-2 as per PWD SR for the Year 2023-24) Ground Floor | Sqm | 672.6 | 672.6 | 501.0 | False | None | None | False | None | False | 336972.6 | 0 | | 3300671 | 115060 | None | code100 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Providing 6 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, finished with waterproofing compound of make FOSROC/ Dr Fixit/ Algiproof, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. 6" wide Arpitha make mesh should be provided at all the masonry rcc joints before starting the plastering works External Wall (S.R.I.No.8.3.2, P.41, Vol-2 as per PWD SR for the Year 2023-24) First Floor | Sqm | 677.32 | 677.32 | 639.0 | False | None | None | False | None | False | 432807.48 | 0 | | 3300672 | 115060 | None | code101 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Providing 6 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, finished with waterproofing compound of make FOSROC/ Dr Fixit/ Algiproof, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. 6" wide Arpitha make mesh should be provided at all the masonry rcc joints before starting the plastering works External Wall (S.R.I.No.8.3.2, P.41, Vol-2 as per PWD SR for the Year 2023-24) Second Floor | Sqm | 682.04 | 682.04 | 639.0 | False | None | None | False | None | False | 435823.56 | 0 | | 3300673 | 115060 | None | code102 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Providing 6 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, finished with waterproofing compound of make FOSROC/ Dr Fixit/ Algiproof, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. 6" wide Arpitha make mesh should be provided at all the masonry rcc joints before starting the plastering works External Wall (S.R.I.No.8.3.2, P.41, Vol-2 as per PWD SR for the Year 2023-24) Third Floor | Sqm | 686.76 | 686.76 | 699.0 | False | None | None | False | None | False | 480045.24 | 0 | | 3300674 | 115060 | None | code103 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Providing 6 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, finished with waterproofing compound of make FOSROC/ Dr Fixit/ Algiproof, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. 6" wide Arpitha make mesh should be provided at all the masonry rcc joints before starting the plastering works External Wall (S.R.I.No.8.3.2, P.41, Vol-2 as per PWD SR for the Year 2023-24) Terrace Floor | Sqm | 691.48 | 691.48 | 196.0 | False | None | None | False | None | False | 135530.08 | 0 | | 3300675 | 115060 | None | code104 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality (Asian/ Berger/ Nippon make only can be used) to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. To be applied by company certified painters only and Guarantee certificate of 7 years must be provided by the company along with the bill -EXTERNAL WALLS Lower Ground Floor | Sqm | 230.1 | 230.1 | 66.0 | False | None | None | False | None | False | 15186.6 | 0 | | 3300676 | 115060 | None | code105 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality (Asian/ Berger/ Nippon make only can be used) to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. To be applied by company certified painters only and Guarantee certificate of 7 years must be provided by the company along with the bill -EXTERNAL WALLS Ground Floor | Sqm | 230.1 | 230.1 | 501.0 | False | None | None | False | None | False | 115280.1 | 0 | | 3300677 | 115060 | None | code106 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality (Asian/ Berger/ Nippon make only can be used) to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. To be applied by company certified painters only and Guarantee certificate of 7 years must be provided by the company along with the bill -EXTERNAL WALLS First Floor | Sqm | 230.1 | 230.1 | 639.0 | False | None | None | False | None | False | 147033.9 | 0 | | 3300678 | 115060 | None | code107 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality (Asian/ Berger/ Nippon make only can be used) to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. To be applied by company certified painters only and Guarantee certificate of 7 years must be provided by the company along with the bill -EXTERNAL WALLS Second Floor | Sqm | 230.1 | 230.1 | 639.0 | False | None | None | False | None | False | 147033.9 | 0 | | 3300679 | 115060 | None | code108 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality (Asian/ Berger/ Nippon make only can be used) to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. To be applied by company certified painters only and Guarantee certificate of 7 years must be provided by the company along with the bill -EXTERNAL WALLS Third Floor | Sqm | 230.1 | 230.1 | 699.0 | False | None | None | False | None | False | 160839.9 | 0 | | 3300680 | 115060 | None | code109 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality (Asian/ Berger/ Nippon make only can be used) to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. To be applied by company certified painters only and Guarantee certificate of 7 years must be provided by the company along with the bill -EXTERNAL WALLS Terrace Floor | Sqm | 230.1 | 230.1 | 196.0 | False | None | None | False | None | False | 45099.6 | 0 | | 3300681 | 115060 | None | code110 | Providing water drip moulds of size 25mmx12mm in external plastering in CM 1:3 to the ceiling bottom edges and sun shade edges as per given drawing. Lower Ground Floor | Rmtr | 180.0 | 180.0 | 75.0 | False | None | None | False | None | False | 13500.0 | 0 | | 3300682 | 115060 | None | code111 | Providing water drip moulds of size 25mmx12mm in external plastering in CM 1:3 to the ceiling bottom edges and sun shade edges as per given drawing. Ground Floor | Rmtr | 180.0 | 180.0 | 335.0 | False | None | None | False | None | False | 60300.0 | 0 | | 3300683 | 115060 | None | code112 | Providing water drip moulds of size 25mmx12mm in external plastering in CM 1:3 to the ceiling bottom edges and sun shade edges as per given drawing. First Floor | Rmtr | 180.0 | 180.0 | 345.0 | False | None | None | False | None | False | 62100.0 | 0 | | 3300684 | 115060 | None | code113 | Providing water drip moulds of size 25mmx12mm in external plastering in CM 1:3 to the ceiling bottom edges and sun shade edges as per given drawing. Second Floor | Rmtr | 180.0 | 180.0 | 345.0 | False | None | None | False | None | False | 62100.0 | 0 | | 3300685 | 115060 | None | code114 | Providing water drip moulds of size 25mmx12mm in external plastering in CM 1:3 to the ceiling bottom edges and sun shade edges as per given drawing. Third Floor | Rmtr | 180.0 | 180.0 | 345.0 | False | None | None | False | None | False | 62100.0 | 0 | | 3300686 | 115060 | None | code115 | Providing water drip moulds of size 25mmx12mm in external plastering in CM 1:3 to the ceiling bottom edges and sun shade edges as per given drawing. Terrace Floor | Rmtr | 180.0 | 180.0 | 75.0 | False | None | None | False | None | False | 13500.0 | 0 | | 3300687 | 115060 | None | code116 | Providing and applying two coats white cement based putty, of approved brand and manufacturer (Asian/ Berger/ Nippon make only can be used), over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. To be applied by company certified painters only INTERNAL WALLS (S.R.I.No. 8.51 P.50, Vol-2 as per PWD SR for the Year 2023-24) Lower Ground floor | Sqm | 120.0 | 120.0 | 1930.0 | False | None | None | False | None | False | 231600.0 | 0 | | 3300688 | 115060 | None | code117 | Providing and applying two coats white cement based putty, of approved brand and manufacturer (Asian/ Berger/ Nippon make only can be used), over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. To be applied by company certified painters only INTERNAL WALLS (S.R.I.No. 8.51 P.50, Vol-2 as per PWD SR for the Year 2023-24) Ground floor | Sqm | 120.0 | 120.0 | 1189.0 | False | None | None | False | None | False | 142680.0 | 0 | | 3300689 | 115060 | None | code118 | Providing and applying two coats white cement based putty, of approved brand and manufacturer (Asian/ Berger/ Nippon make only can be used), over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. To be applied by company certified painters only INTERNAL WALLS (S.R.I.No. 8.51 P.50, Vol-2 as per PWD SR for the Year 2023-24) First floor | Sqm | 120.0 | 120.0 | 1357.0 | False | None | None | False | None | False | 162840.0 | 0 | | 3300690 | 115060 | None | code119 | Providing and applying two coats white cement based putty, of approved brand and manufacturer (Asian/ Berger/ Nippon make only can be used), over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. To be applied by company certified painters only INTERNAL WALLS (S.R.I.No. 8.51 P.50, Vol-2 as per PWD SR for the Year 2023-24) Second floor | Sqm | 120.0 | 120.0 | 1281.0 | False | None | None | False | None | False | 153720.0 | 0 | | 3300691 | 115060 | None | code120 | Providing and applying two coats white cement based putty, of approved brand and manufacturer (Asian/ Berger/ Nippon make only can be used), over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. To be applied by company certified painters only INTERNAL WALLS (S.R.I.No. 8.51 P.50, Vol-2 as per PWD SR for the Year 2023-24) Third floor | Sqm | 120.0 | 120.0 | 747.0 | False | None | None | False | None | False | 89640.0 | 0 | | 3300692 | 115060 | None | code121 | Providing and applying two coats white cement based putty, of approved brand and manufacturer (Asian/ Berger/ Nippon make only can be used), over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. To be applied by company certified painters only INTERNAL WALLS (S.R.I.No. 8.51 P.50, Vol-2 as per PWD SR for the Year 2023-24) Terrace floor | Sqm | 120.0 | 120.0 | 123.0 | False | None | None | False | None | False | 14760.0 | 0 | | 3300693 | 115060 | None | code122 | Wall painting with premium acrylic emulsion paint of interior grade with 1 coat of primer, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture (Asian/ Berger/ Nippon make only can be used), including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge. To be applied by company certified painters only Lower Ground floor | Sqm | 150.0 | 150.0 | 1930.0 | False | None | None | False | None | False | 289500.0 | 0 | | 3300694 | 115060 | None | code123 | Wall painting with premium acrylic emulsion paint of interior grade with 1 coat of primer, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture (Asian/ Berger/ Nippon make only can be used), including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge. To be applied by company certified painters only Ground floor | Sqm | 150.0 | 150.0 | 1189.0 | False | None | None | False | None | False | 178350.0 | 0 | | 3300695 | 115060 | None | code124 | Wall painting with premium acrylic emulsion paint of interior grade with 1 coat of primer, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture (Asian/ Berger/ Nippon make only can be used), including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge. To be applied by company certified painters only First floor | Sqm | 150.0 | 150.0 | 1357.0 | False | None | None | False | None | False | 203550.0 | 0 | | 3300696 | 115060 | None | code125 | Wall painting with premium acrylic emulsion paint of interior grade with 1 coat of primer, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture (Asian/ Berger/ Nippon make only can be used), including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge. To be applied by company certified painters only Second floor | Sqm | 150.0 | 150.0 | 1281.0 | False | None | None | False | None | False | 192150.0 | 0 | | 3300697 | 115060 | None | code126 | Wall painting with premium acrylic emulsion paint of interior grade with 1 coat of primer, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture (Asian/ Berger/ Nippon make only can be used), including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge. To be applied by company certified painters only Third floor | Sqm | 150.0 | 150.0 | 747.0 | False | None | None | False | None | False | 112050.0 | 0 | | 3300698 | 115060 | None | code127 | Wall painting with premium acrylic emulsion paint of interior grade with 1 coat of primer, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture (Asian/ Berger/ Nippon make only can be used), including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge. To be applied by company certified painters only Terrace floor | Sqm | 150.0 | 150.0 | 123.0 | False | None | None | False | None | False | 18450.0 | 0 | | 3300699 | 115060 | None | code128 | Providing and laying Vitrified tiles in different sizes (thickness should not be less than 9 mm and selected by Architects/ Consulting Engineers and Clients)),, with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete. Basic Price of Tile- Rs 75-80 including GST NOTE: Rate to include one time acid wash before filling the joints with grout wherever necessary and also one surf wash at the time of handover. Only Double charge 800 x 800 minimum size tiles of KAJARIA, SOMANY, ASIAN, BELL, VARMORA are allowed and colour to be finalised by client (S.R.I.No. 9.17.2, Page No 61, Vol-2 as per PWD SR for the Year 2023-24) Lower Ground Floor | Sqm | 1800.0 | 1800.0 | 549.0 | False | None | None | False | None | False | 988200.0 | 0 | | 3300700 | 115060 | None | code129 | Providing and laying Vitrified tiles in different sizes (thickness should not be less than 9 mm and selected by Architects/ Consulting Engineers and Clients)),, with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete. Basic Price of Tile- Rs 75-80 including GST NOTE: Rate to include one time acid wash before filling the joints with grout wherever necessary and also one surf wash at the time of handover. Only Double charge 800 x 800 minimum size tiles of KAJARIA, SOMANY, ASIAN, BELL, VARMORA are allowed and colour to be finalised by client (S.R.I.No. 9.17.2, Page No 61, Vol-2 as per PWD SR for the Year 2023-24) Ground Floor | Sqm | 1800.0 | 1800.0 | 621.0 | False | None | None | False | None | False | 1117800.0 | 0 | | 3300701 | 115060 | None | code130 | Providing and laying Vitrified tiles in different sizes (thickness should not be less than 9 mm and selected by Architects/ Consulting Engineers and Clients)),, with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete. Basic Price of Tile- Rs 75-80 including GST NOTE: Rate to include one time acid wash before filling the joints with grout wherever necessary and also one surf wash at the time of handover. Only Double charge 800 x 800 minimum size tiles of KAJARIA, SOMANY, ASIAN, BELL, VARMORA are allowed and colour to be finalised by client (S.R.I.No. 9.17.2, Page No 61, Vol-2 as per PWD SR for the Year 2023-24) First Floor | Sqm | 1920.0 | 1920.0 | 668.0 | False | None | None | False | None | False | 1282560.0 | 0 | | 3300702 | 115060 | None | code131 | Providing and laying Vitrified tiles in different sizes (thickness should not be less than 9 mm and selected by Architects/ Consulting Engineers and Clients)),, with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete. Basic Price of Tile- Rs 75-80 including GST NOTE: Rate to include one time acid wash before filling the joints with grout wherever necessary and also one surf wash at the time of handover. Only Double charge 800 x 800 minimum size tiles of KAJARIA, SOMANY, ASIAN, BELL, VARMORA are allowed and colour to be finalised by client (S.R.I.No. 9.17.2, Page No 61, Vol-2 as per PWD SR for the Year 2023-24) Second Floor | Sqm | 2040.0 | 2040.0 | 712.0 | False | None | None | False | None | False | 1452480.0 | 0 | | 3300703 | 115060 | None | code132 | Providing and laying Vitrified tiles in different sizes (thickness should not be less than 9 mm and selected by Architects/ Consulting Engineers and Clients)),, with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete. Basic Price of Tile- Rs 75-80 including GST NOTE: Rate to include one time acid wash before filling the joints with grout wherever necessary and also one surf wash at the time of handover. Only Double charge 800 x 800 minimum size tiles of KAJARIA, SOMANY, ASIAN, BELL, VARMORA are allowed and colour to be finalised by client (S.R.I.No. 9.17.2, Page No 61, Vol-2 as per PWD SR for the Year 2023-24) Third Floor | Sqm | 2160.0 | 2160.0 | 719.0 | False | None | None | False | None | False | 1553040.0 | 0 | | 3300704 | 115060 | None | code133 | Providing and laying Ceramic glazed floor ANTI SKID tiles of size 300x300 mm OR 600X600 mm (thickness to be specified by the manufacturer and as selected by Architects/ Consulting Engineers and Client)) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 including pointing the joints with white cement and matching pigment etc., complete. ANTI SKID SERIES- KAJARIA, ASIAN, BELL, VARMORA are allowed and colour to be finalised by client OR Consulting Engineer. Basic Price of Tile- Rs 45/-/Sft NOTE: Rate to include one time acid wash and filling the joints with grout wherever necessary and also one surf wash at the time of handover. (S.R.I.No. 9.11, Page No 60, Vol-2 as per PWD SR for the Year 2023-24) Lower Ground FLoor | Sqm | 1300.0 | 1300.0 | 7.0 | False | None | None | False | None | False | 9100.0 | 0 | | 3300705 | 115060 | None | code134 | Providing and laying Ceramic glazed floor ANTI SKID tiles of size 300x300 mm OR 600X600 mm (thickness to be specified by the manufacturer and as selected by Architects/ Consulting Engineers and Client)) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 including pointing the joints with white cement and matching pigment etc., complete. ANTI SKID SERIES- KAJARIA, ASIAN, BELL, VARMORA are allowed and colour to be finalised by client OR Consulting Engineer. Basic Price of Tile- Rs 45/-/Sft NOTE: Rate to include one time acid wash and filling the joints with grout wherever necessary and also one surf wash at the time of handover. (S.R.I.No. 9.11, Page No 60, Vol-2 as per PWD SR for the Year 2023-24) First FLoor | Sqm | 1425.0 | 1425.0 | 24.5 | False | None | None | False | None | False | 34912.5 | 0 | | 3300706 | 115060 | None | code135 | Providing and laying Ceramic glazed floor ANTI SKID tiles of size 300x300 mm OR 600X600 mm (thickness to be specified by the manufacturer and as selected by Architects/ Consulting Engineers and Client)) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 including pointing the joints with white cement and matching pigment etc., complete. ANTI SKID SERIES- KAJARIA, ASIAN, BELL, VARMORA are allowed and colour to be finalised by client OR Consulting Engineer. Basic Price of Tile- Rs 45/-/Sft NOTE: Rate to include one time acid wash and filling the joints with grout wherever necessary and also one surf wash at the time of handover. (S.R.I.No. 9.11, Page No 60, Vol-2 as per PWD SR for the Year 2023-24) Second FLoor | Sqm | 1550.0 | 1550.0 | 24.5 | False | None | None | False | None | False | 37975.0 | 0 | | 3300707 | 115060 | None | code136 | Providing and laying Ceramic glazed floor ANTI SKID tiles of size 300x300 mm OR 600X600 mm (thickness to be specified by the manufacturer and as selected by Architects/ Consulting Engineers and Client)) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 including pointing the joints with white cement and matching pigment etc., complete. ANTI SKID SERIES- KAJARIA, ASIAN, BELL, VARMORA are allowed and colour to be finalised by client OR Consulting Engineer. Basic Price of Tile- Rs 45/-/Sft NOTE: Rate to include one time acid wash and filling the joints with grout wherever necessary and also one surf wash at the time of handover. (S.R.I.No. 9.11, Page No 60, Vol-2 as per PWD SR for the Year 2023-24) Third FLoor | Sqm | 1675.0 | 1675.0 | 24.5 | False | None | None | False | None | False | 41037.5 | 0 | | 3300708 | 115060 | None | code137 | Providing skirting, dadooing, rises of steps with white glazed tiles 8mm thick (tiles selected by Architects/ Consulting Engineers and Client) on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. Basic Price of Tile- Rs 65 including GST NOTE: Rate to include one time acid wash before filling the joints with grout wherever necessary and also one surf wash at the time of handover. Only 600X 1200mm tiles of KAJARIA, SOMANY, ASIAN, BELL, VARMORA are allowed and colour to be finalised by client (S.R.I.No. 9.38 P.65, Vol-2 as per PWD SR for the Year 2023-24) Lower Ground floor | Sqm | 1450.0 | 1450.0 | 28.0 | False | None | None | False | None | False | 40600.0 | 0 | | 3300709 | 115060 | None | code138 | Providing skirting, dadooing, rises of steps with white glazed tiles 8mm thick (tiles selected by Architects/ Consulting Engineers and Client) on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. Basic Price of Tile- Rs 65 including GST NOTE: Rate to include one time acid wash before filling the joints with grout wherever necessary and also one surf wash at the time of handover. Only 600X 1200mm tiles of KAJARIA, SOMANY, ASIAN, BELL, VARMORA are allowed and colour to be finalised by client (S.R.I.No. 9.38 P.65, Vol-2 as per PWD SR for the Year 2023-24) First floor | Sqm | 1575.0 | 1575.0 | 83.0 | False | None | None | False | None | False | 130725.0 | 0 | | 3300710 | 115060 | None | code139 | Providing skirting, dadooing, rises of steps with white glazed tiles 8mm thick (tiles selected by Architects/ Consulting Engineers and Client) on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. Basic Price of Tile- Rs 65 including GST NOTE: Rate to include one time acid wash before filling the joints with grout wherever necessary and also one surf wash at the time of handover. Only 600X 1200mm tiles of KAJARIA, SOMANY, ASIAN, BELL, VARMORA are allowed and colour to be finalised by client (S.R.I.No. 9.38 P.65, Vol-2 as per PWD SR for the Year 2023-24) Second floor | Sqm | 1700.0 | 1700.0 | 83.0 | False | None | None | False | None | False | 141100.0 | 0 | | 3300711 | 115060 | None | code140 | Providing skirting, dadooing, rises of steps with white glazed tiles 8mm thick (tiles selected by Architects/ Consulting Engineers and Client) on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. Basic Price of Tile- Rs 65 including GST NOTE: Rate to include one time acid wash before filling the joints with grout wherever necessary and also one surf wash at the time of handover. Only 600X 1200mm tiles of KAJARIA, SOMANY, ASIAN, BELL, VARMORA are allowed and colour to be finalised by client (S.R.I.No. 9.38 P.65, Vol-2 as per PWD SR for the Year 2023-24) Third floor | Sqm | 1825.0 | 1825.0 | 83.0 | False | None | None | False | None | False | 151475.0 | 0 | | 3300712 | 115060 | None | code141 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. (as selected by the Client & Architect/Consulting Engineers) Granite sizes as 3'x6' minimum sizes of basic prive range from Rs 125 to Rs 150 including GST | Sqm | 3100.0 | 3100.0 | 293.0 | False | None | None | False | None | False | 908300.0 | 0 | | 3300713 | 115060 | None | code142 | Providing full nosing for 10mm thick granite slab using required machinery including cost and conveyance of all materials, labour for all items of work, HOM of equipment etc., complete as per specification. | Rmtr | 380.0 | 380.0 | 547.0 | False | None | None | False | None | False | 207860.0 | 0 | | 3300714 | 115060 | None | code143 | Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. Lower Ground floor | Sqm | 3479.77 | 3479.77 | 97.5 | False | None | None | False | None | False | 339277.575 | 0 | | 3300715 | 115060 | None | code144 | Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. Upper Ground floor | Sqm | 3479.77 | 3479.77 | 76.0 | False | None | None | False | None | False | 264462.52 | 0 | | 3300716 | 115060 | None | code145 | Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. First floor | Sqm | 3479.77 | 3479.77 | 54.0 | False | None | None | False | None | False | 187907.58 | 0 | | 3300717 | 115060 | None | code146 | Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. Second floor | Sqm | 3479.77 | 3479.77 | 11.0 | False | None | None | False | None | False | 38277.47 | 0 | | 3300718 | 115060 | None | code147 | Providing and fixing 125mm x 65mm GRP door frame with 30mm thick Moulded GFRC Door Shutter of colour as selected by the client and must be waterproof , fabricated using E-glass chopped strand mat (CSM).U.V-stabilized isopthalic gelcoat &isopthalic resins. The thickness of the GRP skin shall not be less than 2mm each side. The door frame consists of four segments, which provided with plug -in-socket arrangement in-situ in the mould. 6 numbers of 260mm X 25mm X 5mm size 'S' shapd M.S.flat hold fast shall be provided with the frame including cost of fixtures using 3 nos of 5" SS 304 Grade hinges, 8" Tower Bolt, 8" Latch and 10" Aldrop and 2 nos of 8" handles -Mookambika make | Sqm | 6500.0 | 6500.0 | 36.0 | False | None | None | False | None | False | 234000.0 | 0 | | 3300719 | 115060 | None | code148 | Providing and fixing stainless steel ( Grade 304) railing made of 2" round 16 guage pipe at top and pillars at every 4th thread and 2 nos at the landings , 5 nos of 1" round 16 guage pipe etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel anchor bolts of 75mm x 10mm with SS Doom Nut etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (As per attached drawings ) ALL MATERIALS USED MUST BE SS 304 GRADE OF MAKE JSW ONLY AFTER FIXING AND GRINDING OF THE RAILING IT MUST BE PROPERLY WRAPPED TILL THE HAND OVER AND AT THE END AFTER PERMISSION FROM THE CONSULTANT ENGINNER IT MUST BE REMOVED AND BUFFING TO BE DONE. Lower Ground Floor | Sqm | 7100.0 | 7100.0 | 12.5 | False | None | None | False | None | False | 88750.0 | 0 | | 3300720 | 115060 | None | code149 | Providing and fixing stainless steel ( Grade 304) railing made of 2" round 16 guage pipe at top and pillars at every 4th thread and 2 nos at the landings , 5 nos of 1" round 16 guage pipe etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel anchor bolts of 75mm x 10mm with SS Doom Nut etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (As per attached drawings ) ALL MATERIALS USED MUST BE SS 304 GRADE OF MAKE JSW ONLY AFTER FIXING AND GRINDING OF THE RAILING IT MUST BE PROPERLY WRAPPED TILL THE HAND OVER AND AT THE END AFTER PERMISSION FROM THE CONSULTANT ENGINNER IT MUST BE REMOVED AND BUFFING TO BE DONE. Upper Ground Floor | Sqm | 7100.0 | 7100.0 | 27.0 | False | None | None | False | None | False | 191700.0 | 0 | | 3300721 | 115060 | None | code150 | Providing and fixing stainless steel ( Grade 304) railing made of 2" round 16 guage pipe at top and pillars at every 4th thread and 2 nos at the landings , 5 nos of 1" round 16 guage pipe etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel anchor bolts of 75mm x 10mm with SS Doom Nut etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (As per attached drawings ) ALL MATERIALS USED MUST BE SS 304 GRADE OF MAKE JSW ONLY AFTER FIXING AND GRINDING OF THE RAILING IT MUST BE PROPERLY WRAPPED TILL THE HAND OVER AND AT THE END AFTER PERMISSION FROM THE CONSULTANT ENGINNER IT MUST BE REMOVED AND BUFFING TO BE DONE. First Floor | Sqm | 7100.0 | 7100.0 | 42.0 | False | None | None | False | None | False | 298200.0 | 0 | | 3300722 | 115060 | None | code151 | Providing and fixing stainless steel ( Grade 304) railing made of 2" round 16 guage pipe at top and pillars at every 4th thread and 2 nos at the landings , 5 nos of 1" round 16 guage pipe etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel anchor bolts of 75mm x 10mm with SS Doom Nut etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (As per attached drawings ) ALL MATERIALS USED MUST BE SS 304 GRADE OF MAKE JSW ONLY AFTER FIXING AND GRINDING OF THE RAILING IT MUST BE PROPERLY WRAPPED TILL THE HAND OVER AND AT THE END AFTER PERMISSION FROM THE CONSULTANT ENGINNER IT MUST BE REMOVED AND BUFFING TO BE DONE. Second Floor | Sqm | 7100.0 | 7100.0 | 49.5 | False | None | None | False | None | False | 351450.0 | 0 | | 3300723 | 115060 | None | code152 | Providing and fixing stainless steel ( Grade 304) railing made of 2" round 16 guage pipe at top and pillars at every 4th thread and 2 nos at the landings , 5 nos of 1" round 16 guage pipe etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel anchor bolts of 75mm x 10mm with SS Doom Nut etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (As per attached drawings ) ALL MATERIALS USED MUST BE SS 304 GRADE OF MAKE JSW ONLY AFTER FIXING AND GRINDING OF THE RAILING IT MUST BE PROPERLY WRAPPED TILL THE HAND OVER AND AT THE END AFTER PERMISSION FROM THE CONSULTANT ENGINNER IT MUST BE REMOVED AND BUFFING TO BE DONE. Third Floor | Sqm | 7100.0 | 7100.0 | 11.0 | False | None | None | False | None | False | 78100.0 | 0 | | 3300724 | 115060 | None | code153 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc. | Kgs | 212.4 | 212.4 | 12800.0 | False | None | None | False | None | False | 2718720.0 | 0 | | 3300725 | 115060 | None | code154 | Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. - ONE COAT PRIMER WITH TWO COAT ENAMEL PAINT- Asian Make Antirust | Sqm | 300.0 | 300.0 | 850.0 | False | None | None | False | None | False | 255000.0 | 0 | | 3300726 | 115060 | None | code155 | Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (Steel grade Yst 310 ) (S.R.I.No. 11.16.2, P.81, Vol-2 PWD SR) | Kgs | 179.74 | 179.74 | 8100.0 | False | None | None | False | None | False | 1455894.0 | 0 | | 3300727 | 115060 | None | code156 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. Only JSW make allowed. (S.R.I.No. 7.38, P.26, Vol-2 PWD SR ) | Sqm | 750.67 | 750.67 | 587.0 | False | None | None | False | None | False | 440643.29 | 0 | | 3300728 | 115060 | None | code157 | Providing and constructing un-reinforced plain cement concrete pavement, thickness as per design, over prepared sub base, with 43 grade cement or any other type as per Clause 1501.2.2 M30 (Grade), coarse and fine aggregates conforming to IS:383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a concrete mixer of not less than 0.2 cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, laying and fixing of 125 micron thick polythene film, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with shovels, rakes, compacted using needle, screed and plate vibrators and finished in continuous operation including construction joints, , primer, sealant , curing of concrete slabs for 14- days, and water finishing to lines and grade as per drawing and technical specification clause 1501 with all lead, lifts, loading & unloading charges, cost and conveyance of all materials, labour, equipments etc., complete. as per the directions of the Engineer-in-charge of the work. (S.R.I.No. 20.29, P.138, Vol-3 PWD SR) | Cum | 8423.88 | 8423.88 | 121.0 | False | None | None | False | None | False | 1019289.48 | 0 | | 3300729 | 115060 | None | code158 | Cutting transverse contraction joints 3 to 4 mm wide and depth 60mm in concrete slab using concrete cutting machine with diamond studded saw within 48 hours of casting of bay / slab etc. complete including subsequent widening of the groove 8 to 10 mm. wide at top having depth of 15 mm. as directed by Engineer incharge. (S.R.I.No. 4, morth-602.6.3 , P.146, Vol-3 PWD SR) | Rmtr | 82.6 | 82.6 | 800.0 | False | None | None | False | None | False | 66080.0 | 0 | | 3300730 | 115060 | None | code159 | Providing to contraction joints polysuphide sealent (Pouring grade) confirming to BS : 5212 - 1989 into sawed groove widened at top for sealent reservoir of specified size and shape as per detailed drawing including fixing Polyethylene foam backer rod of required diameter (approx. 25% larger than the initial 3 mm.to 4 mm. joint) overlaid with bond breaking tape as per detailed drawing. Item includes cleaning the joints with water jet / air compressor and allowing joint to become thoroughly dry before sealent is applied and applying primer. (A) Contraction and longitudinal joints (15 mm. deep x 8 mm.wide). | Rmtr | 200.0 | 200.0 | 800.0 | False | None | None | False | None | False | 160000.0 | 0 | | 3300731 | 115060 | None | code160 | Providing and laying 150 micron Low Density Polyethylene (LDPE) sheet confirming to IS 3395 : 1997 below concrete pavement including all materials and labour complete. | Sqm | 25.0 | 25.0 | 805.0 | False | None | None | False | None | False | 20125.0 | 0 | | 3300732 | 115060 | None | code161 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work-Depth exceeding 1.5 m, but not exceeding 3 m (S.R.I.No. 1.15.2, P.9, Vol-1 PWD SR ) | Cum | 141.54 | 141.54 | 180.0 | False | None | None | False | None | False | 25477.2 | 0 | | 3300733 | 115060 | None | code162 | Providing and Filling in foundation with granite / trap broken metal 100mm. And down size & with approved sand including hand packing, ramming, watering, including cost of all materials and labour with all lead and lift complete as per specifications.- (S.R.I.No. 1.23, P.11, Vol-1 as per PWD SR for the Year 2023-24) | Cum | 3544.53 | 3544.53 | 16.0 | False | None | None | False | None | False | 56712.48 | 0 | | 3300734 | 115060 | None | code163 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates (S.R.I.No.2.1.2, P.15, Vol-1 PWD SR ) | Cum | 7485.54 | 7485.54 | 11.0 | False | None | None | False | None | False | 82340.94 | 0 | | 3300735 | 115060 | None | code164 | Providing and laying in position Reinforced cement concrete for all Foundation works.The granite/trap /basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement )M25 Design Mix Using 20 mm nominal size graded crushed coarseaggregates (S.R.I.No.2.2.2.1, P.15, Vol-1 PWD SR) Footing | Cum | 9043.56 | 9043.56 | 8.0 | False | None | None | False | None | False | 72348.48 | 0 | | 3300736 | 115060 | None | code165 | Providing and laying in position Reinforced cement concrete for all Foundation works.The granite/trap /basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement )M25 Design Mix Using 20 mm nominal size graded crushed coarseaggregates (S.R.I.No.2.2.2.1, P.15, Vol-1 PWD SR) Top slab | Cum | 13565.56 | 13565.56 | 7.0 | False | None | None | False | None | False | 94958.92 | 0 | | 3300737 | 115060 | None | code166 | Providing and laying in position Reinforced cement concrete for all Foundation works.The granite/trap /basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement )M25 Design Mix Using 20 mm nominal size graded crushed coarseaggregates (S.R.I.No.2.2.2.1, P.15, Vol-1 PWD SR) Beam | Cum | 14469.94 | 14469.94 | 0.5 | False | None | None | False | None | False | 7234.97 | 0 | | 3300738 | 115060 | None | code167 | Providing and laying in position Reinforced cement concrete for all Foundation works.The granite/trap /basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement )M25 Design Mix Using 20 mm nominal size graded crushed coarseaggregates (S.R.I.No.2.2.2.1, P.15, Vol-1 PWD SR) Wall | Cum | 9948.08 | 9948.08 | 21.0 | False | None | None | False | None | False | 208909.68 | 0 | | 3300739 | 115060 | None | code168 | Supplying, Fitting and Placing TMT Fe 500 & above Reinforcement in Foundation / Substructure / Superstructure complete as per Drawing and Technical Specifications.(S.R.I.No. 9.3, P-71, Vol-3 PWD SR) | Tonne | 118226.37 | 118226.37 | 4.19 | False | None | None | False | None | False | 495368.4903 | 0 | | 3300740 | 115060 | None | code169 | Providing & constructing granite or trap or basalt size stone dry masonry in foundation using stones hommer dressed in courses not less than 20cm high including providing & constructing bond stones at every two meteres apart in each courses including cost. Bond stone masonry in circular manner Pg N. 385 SL no. 42.11 | Cum | 8443.7 | 8443.7 | 12.0 | False | None | None | False | None | False | 101324.4 | 0 | | 3300741 | 115060 | None | code170 | Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge.(S.R.I.No. 15.1, P-133, Vol-2 PWD SR ) | Sqm | 670.05 | 670.05 | 154.0 | False | None | None | False | None | False | 103187.7 | 0 | | 3300742 | 115060 | None | code171 | Providing and fixing Fibrelite manhole cover, Manhole composite covers and frames are made from molded and reinforced composite polymer Covers have the ability to withstand a traffic load of at least 20 Tonne and above (Square 600mm X 600mm) sump and leach pit | LS | 5900.0 | 5900.0 | 5.0 | False | None | None | False | None | False | 29500.0 | 0 |
|