1718197368000 | 0 | None | None | Other Works | construction of RCC Cistern tank and providing RCC Benches near bus stand ward no 12 in Shedbal town | 94975.56 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3280804 | 113873 | None | code01 | Manual Means: Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected tuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work.PWD Common DSR 2023-24 Volume 1 (P No: 5 I.No:1.4.1) | Cum | 254.1 | 254.1 | 20.25 | False | None | None | False | None | False | 5145.525 | 0 | 3280805 | 113873 | None | code02 | Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for:PWD Common DSR 2023-24 Volume 5 (P No:113 I.No:10.1.6) 1)PVC pipes 90mm dia., 6 kg/sqcm & class 3 Finolex/jain Company or Equivalent make | Mtr | 308.7 | 308.7 | 50.0 | False | None | None | False | None | False | 15435.0 | 0 | 3280806 | 113873 | None | code03 | Supplying and fixing DI Resilient seated soft sealing SLUICE VALVE of variouis dia. with body bonnet of ductile iron (DI) conforming to IS-1865 and of grade GGG 40/50, shaft of stainless steel, wedge fully rubber lined with EDPM seals of NBR and the valves should be vacum tight and 100% leak proof with face to face dimensions as per IS 14846-2000 only. The stem sealing should be with toroidal sealing rings (minimum 2 “ O “ rings). Body and bonut should be coated with Electrostatically applied Epoxy Powder Coating with minimum coating thickness of 250 micron both inside and outside. The rate is inclusive of cost of valves, T.P set, galvanized bolts & nuts and rubber insertions etc. but excluding earth work. (Note: TP set should be considered only for DI pipes estimate. For MS pipes estimates, TP sets cost of corresponding dia shall be deducted from the SR rates of valves and provision for corresponding dia MS flanges should be made in the estimate.) For PN-10:. PWD Common DSR 2023-24 Volume 5 (P No:22 I.No:.2.23.2 ) For Suilce Valve of PN -10.0 and 80mm | Each | 10912.65 | 10912.65 | 1.0 | False | None | None | False | None | False | 10912.65 | 0 | 3280807 | 113873 | None | code04 | Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m , and lift upto 1.5 m. Including cost of all labour complete as per specifications PWD Common DSR 2023-24 Volume 1 (P No: 7 I.No:1.10) | Cum | 168.0 | 168.0 | 20.25 | False | None | None | False | None | False | 3402.0 | 0 | 3280808 | 113873 | None | code05 | Earth work in surface excavation by manual means for lowering & levelling the ground by chiselling and wedging in Hard rock for all works other than foundation & depth not exceeding 100 mm as per drawing and technical specifications, including setting out, barricading, caution lights, dressing of excavated surfaces, disposing off the excavated spalls/stuff & stacking the selected spall/ stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work.. PWD Common DSR 2023-24 Volume 1 (P No: 05 I.No:13)) | Cum | 185.85 | 185.85 | 4.73 | False | None | None | False | None | False | 879.0705 | 0 | 3280809 | 113873 | None | code06 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates PWD Common DSR 2023-24Volume 1 (P No: 15 I.No:2.1.2) | Cum | 5947.2 | 5947.2 | 0.29 | False | None | None | False | None | False | 1724.688 | 0 | 3280810 | 113873 | None | code07 | Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with :Cement mortar 1:6 (1 cement : 6 coarse sand) (Comman SR-2023-24,Vol-2)I.NO-5.1.1 Page No-09 | Cum | 5891.55 | 5891.55 | 3.08 | False | None | None | False | None | False | 18145.974 | 0 | 3280811 | 113873 | None | code08 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates PWD Common DSR 2023-24 Volume 1 (P No: 15 I.No:2.1.4) | Cum | 6527.85 | 6527.85 | 0.38 | False | None | None | False | None | False | 2480.583 | 0 | 3280812 | 113873 | None | code09 | Ruled/ Flush pointing on White sand stone masonry surface with lime, surkhi and marble dust mortar in the ratio of 1:1.5:1/2 ((One lime : 1.5 surkhi (15% dark red and 85% light yellow surkhi) : 1/2 marble dust)). (The rate is inclusive of all materials & labours involved except scaffolding).(PWD Common DSR 2023-24 Volume 2 (P No:214 I.No:21.6) | Sqm | 258.3 | 258.3 | 3.6 | False | None | None | False | None | False | 929.88 | 0 | 3280813 | 113873 | None | code10 | RCC hume pipe Circular pump house: Supplying precast RCC Circular Hume pipe pump house with M.S door and RCC conical roof as per specification and drawings - Internal dia Mtr. 1200 mm & height of 2.5 Mtr. With Wall thickness 65mm.(Toper) (PRED SR 2023-24 Page no 116 Valume V Item No 10.6). | Each | 17221.05 | 17221.05 | 1.0 | False | None | None | False | None | False | 17221.05 | 0 | 3280814 | 113873 | None | code11 | Providing, Laying and Fixing GI pipes conforming to IS 1239:1990 with latest amendments complete with GI fittings (excluding the cost of fittings) with cuts and threads wherever necessary, including testing for water tightness, with all lead and commissioning. (contractor will make his own arrangements for procuring water for testing) Medium Duty GI pipe of 50mm dia (PRED SR 2023-24 Page no 127 Valume V Item No 11.1.6). | Mtr | 464.1 | 464.1 | 2.5 | False | None | None | False | None | False | 1160.25 | 0 | 3280815 | 113873 | None | code12 | Providing, Laying and Fixing GI pipes conforming to IS 1239:1990 with latest amendments complete with GI fittings (excluding the cost of fittings) with cuts and threads wherever necessary, including testing for water tightness, with all lead and commissioning. (contractor will make his own arrangements for procuring water for testing) Medium Duty GI pipe of 20mm dia (PRED SR 2021-22 Page no 127 Valume V Item No11.1.2). | Mtr | 236.25 | 236.25 | 2.0 | False | None | None | False | None | False | 472.5 | 0 | 3280816 | 113873 | None | code13 | Providing GM gland cocks tested against hydraulic pressure of 20 Kg/m² with ISI mark.(PRED SR 2023-24 Page no 134 Valume V Item No 11.19.1) For 15 mm dia GM gland cocks | Each | 308.7 | 308.7 | 1.0 | False | None | None | False | None | False | 308.7 | 0 | 3280817 | 113873 | None | code14 | Providing and fixing GI union in existing GI pipe line, cutting and threading the pipe and making long screws including excavation, refilling the earth or cutting of wall and making good the same complete wherever required etc. for:(PRED SR 2023-24 Page no 128 Valume V Item No 11.4.5) 20.88.5: 40 mm nominal bore | Each | 513.45 | 513.45 | 1.0 | False | None | None | False | None | False | 513.45 | 0 | 3280818 | 113873 | None | code15 | Providing and fixing GI union in existing GI pipe line, cutting and threading the pipe and making long screws including excavation, refilling the earth or cutting of wall and making good the same complete wherever required etc. for:(PRED SR 2023-24 Page no 128 Valume V Item No 11.4.8) 20.88.8: 80 mm nominal bore | Each | 1093.05 | 1093.05 | 1.0 | False | None | None | False | None | False | 1093.05 | 0 | 3280819 | 113873 | None | code16 | Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m , and lift upto 1.5 m. Including cost of all labour complete as per specifications PWD Common DSR 2023-24 Volume 1 (P No: 7 I.No:1.10) | Cum | 168.0 | 168.0 | 0.9 | False | None | None | False | None | False | 151.2 | 0 | 3280820 | 113873 | None | code17 | Providing and fixing RCC BENCHES OF Standard size 2.1 m x 0.75 m x ht 0.90 m and thickness 50 mm including transportation loading unloading all taxes and painting charges all lab & materiai charges included MR. | LS | 3000.0 | 3000.0 | 5.0 | False | None | None | False | None | False | 15000.0 | 0 |
|