noticeInvitingTenderDTO
createdTs1718695536166
version3
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee2500.00
emd169300.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose04-07-2024 17:30:00
tenderQueryClose03-07-2024 17:30:00
technicalBidOpen06-07-2024 11:00:00
publishedDate19-06-2024 11:44:01
publishedByPostCMC_MCOM_KKP
publishedByUserKPE13704 - MAHADEVA M S
bidValidityPeriod90
noOfCalls1
preBidMeetingDate25-06-2024 11:00:00
preBidMeetingYnTrue
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonJunior Engineer
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumber08027524986
mobileNumber9986115737
tenderSupplierListNone
tenderSchedule
createdTs1718695536194
version4
createdDateNone
modifiedDateNone
tenderNumberDMA/2024-25/BD/WORK_INDENT18614
titleConstruction of Proposed 10TPD MRF Centre (Material Recovery Facility Primary and Secondary Shed) of PEB Structure At Kanakapura
descriptionConstruction of Material Recovery Facility shed
categoryWORKS
categoryTextWorks
ecv9990000.00
deptNameDirectorate of Municipal Administration
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnTrue
location2387
locationNameDMA City Municipal Council Kanakapura
provisionalAmount10000000.0
groupOverheadTotal1525077.72
fileNumbercmckkp/ts-1/sbm2/cr/7/2024-25
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17186955360000NoneNoneBuildingsConstruction of Proposed 10TPD MRF Centre (Material Recovery Facility Primary and Secondary Shed) of PEB Structure At Kanakapura8143189.05
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3300025115034Nonecode01Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. (Item No. 1.14.1 Page No. 8 Vol.1 PWD SR)Cum105.06105.0692.0FalseNoneNoneFalseNoneFalse9665.520
3300026115034Nonecode02Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates (The cost of steel reinforcement & formwork shall be paid separately. Specification No. KBS 2.1, (Item No. 2.1.2 Page No. 15 Vol.1 PWD SR)Cum5833.925833.9290.01FalseNoneNoneFalseNoneFalse525111.13920
3300027115034Nonecode03Providing and laying in position cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes ,labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately). M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Specification No. KBS 2.3., 2.3 (Item No. 2.3.2 Page No. 16 Vol.1 PWD SR & Appendix I page No.115)Cum7192.87192.824.16FalseNoneNoneFalseNoneFalse173778.0480
3300028115034Nonecode04Providing and laying in position cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes ,labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately). M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Specification No. KBS 2.3., 2.3 (Item No. 2.3.2 Page No. 16 Vol.1 PWD SR & Appendix I page No.115Cum11210.411210.49.21FalseNoneNoneFalseNoneFalse103247.7840
3300029115034Nonecode05Providing and laying in position cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes ,labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately). M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Specification No. KBS 2.3., 2.3 (Item No. 2.3.2 Page No. 16 Vol.1 PWD SR & Appendix I page No.115Cum7192.87192.8106.21FalseNoneNoneFalseNoneFalse763947.2880
3300030115034Nonecode06Providing and laying in cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately). M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Item No. 2.2.3 Page No. 15 Vol.1 PWD SR & Appendix I page No.115)Cum9694.089694.0810.71FalseNoneNoneFalseNoneFalse103823.59680
3300031115034Nonecode07Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification .(Item No. 2.11 Page No. 18 Vol.1 PWD SR)Tonne92140.7192140.718.76FalseNoneNoneFalseNoneFalse807152.61960
3300032115034Nonecode08Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) . (Item No. 5.4 Page No. 9 Vol.2 PWD SR)Cum6580.676580.6741.7939FalseNoneNoneFalseNoneFalse275031.8639130
3300033115034Nonecode09Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,allmaterials,usage& all other appurtenaces required to complete the work (Item No. 1.8 Page No. 7 Vol.1 PWD SR)Cum488.22488.22523.121FalseNoneNoneFalseNoneFalse255398.134620
3300034115034Nonecode10Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. (Item No. 6.33 Page No. 17 Vol.2 PWD SR)Sqm1267.931267.93274.416FalseNoneNoneFalseNoneFalse347940.278880
3300035115034Nonecode11Providing 15mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(Item No. 8.2.1, Page No. 41, Vol.2)Sqm303.85303.85597.2052FalseNoneNoneFalseNoneFalse181460.800020
3300036115034Nonecode12Providing and fixing Structural Steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-inCharge. (Item No. 11.2, Page No. 77, Vol.2)Kg116.39116.3927260.0FalseNoneNoneFalseNoneFalse3172791.40
3300037115034Nonecode13Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05 %) total coated thickness with zinc coating 120 g/m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineerin-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. (Item No. 7.38, Page No. 26, Vol.2)Sqm585.04585.041623.508FalseNoneNoneFalseNoneFalse949817.120320
3300038115034Nonecode14Finishing with Deluxe Multi surface paint system for interiors and exteriors using pirmer as per manufactures specifications: Two coats applied on walls @1.25L/10sqm over and including one coat of special primer applied @0.75L/10sqm with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge (The gloss should be 50% @ 60 degree angle with 10 years life) (I.no:8.33.1, Pg.no:46, Vol-2)Sqm162.74162.74599.37FalseNoneNoneFalseNoneFalse97541.47380
3300039115034Nonecode15Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (Item No. 11.6.1, Page No. 76, Vol.2)Sqm2711.992711.9933.75FalseNoneNoneFalseNoneFalse91529.66250
3300040115034Nonecode16Extra for providing 2 HP Mild Steel Auto Reverse Shutter Gearbox for operating rolling shutters including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.(Item No. 11.8.4, Page No. 79, Vol.2)No25426.5825426.582.0FalseNoneNoneFalseNoneFalse50853.160
3300041115034Nonecode17Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For Fixed Portion: Powder coated aluminium (minimum thickness of powder coating 50 micron) including cost of materials, labour, usage charges of machinery complete as per specifications..(Item No. 11.35.1.1, Page No. 87, Vol.2)Kg465.56465.56480.0FalseNoneNoneFalseNoneFalse223468.80
3300042115034Nonecode18Painting steel work with Deluxe Multi surfce paint to give an even shade. Two cot applied @ 0.9L/10sqm over an under coat of primer applie @0.80L/10sqm of approved brand and manufacture including preparing the surface after throughly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge (I.N0:8.33.3, Pg.no:47, Vol-2)Sqm143.17143.1774.25FalseNoneNoneFalseNoneFalse10630.37250
17186955360000NoneNoneBuildingsConstruction of Proposed 10TPD MRF Centre (Material Recovery Facility Primary and Secondary Shed) of PEB Structure At Kanakapura321733.23
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3300043115035Nonecode01Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws,bolts,nuts,necessary phase separators,handle and wiring complete.Protection of Overload and Short circuit with adjustable thermal magnetic release,Microprocessor release shall have Earth Fault as per IS/IEC60947-2. (Icu=100%lcs).In 4P MCCB,all Poles should have protection for Short-Cicrcuit/OverLoad.For Microprocessor MCCB S Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open).Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. (P.No.17, I.No.5.15.1 & 5.15.9 in CSR Electrical SR Volume-6 2023-24) Three Pole- 100 A 25 kAEach6268.586268.583.0FalseNoneNoneFalseNoneFalse18805.740
3300044115035Nonecode02Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws,bolts,nuts,necessary phase separators,handle and wiring complete.Protection of Overload and Short circuit with adjustable thermal magnetic release,Microprocessor release shall have Earth Fault as per IS/IEC60947-2. (Icu=100%lcs).In 4P MCCB,all Poles should have protection for Short-Cicrcuit/OverLoad.For Microprocessor MCCB S Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open).Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. (P.No.17, I.No.5.15.1 & 5.15.9 in CSR Electrical SR Volume-6 2023-24) Four Pole-100 A 25 kAEach8741.618741.611.0FalseNoneNoneFalseNoneFalse8741.610
3300045115035Nonecode03Supplying and fixing of Modular MCB Devices (Tripper) With Breaking capacity of 6kA.(P.No.21, I.No.5.46.1 & 5.46.6 in CSR Electrical SR Volume-6 2023-24) 16-32 A SPEach216.3216.36.0FalseNoneNoneFalseNoneFalse1297.80
3300046115035Nonecode04Supplying and fixing of Modular MCB Devices (Tripper) With Breaking capacity of 6kA.(P.No.21, I.No.5.46.1 & 5.46.6 in CSR Electrical SR Volume-6 2023-24) 63 A TPEach1230.851230.858.0FalseNoneNoneFalseNoneFalse9846.80
3300047115035Nonecode05Supplying A rated 3 phase with neutral busbar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve,mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board.The busbar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 100 A 4 x 30 x 6 mm Aluminium StripsMtr2538.952538.9510.0FalseNoneNoneFalseNoneFalse25389.50
3300048115035Nonecode06SupplyingandfixingangleironframeworkfabricatedoutofM.S.angleiron..andM.S.Flat......withbolts,washersetc.,andpaintedwith 2 coats of red oxide and then two coats of approved paint.(P.No.20, I.No.5.41.1 in CSR Electrical SR Volume-6 2023-24)Mtr314.15314.156.0FalseNoneNoneFalseNoneFalse1884.90
3300049115035Nonecode07Supply and fixing of 3pole power contactor with NO/NC contacts on existing wood/panel board using necessary bolts,nuts,washers and wiring etc., complete with AC-3 Rating and as per IS-13947.(P.No.15, I.No.5.13.1 in CSR Electrical SR Volume-6 2023-24) 25 AEach1328.71328.79.0FalseNoneNoneFalseNoneFalse11958.30
3300050115035Nonecode08Supplying and fixing Micro processor Based Astro nomical timer Switch with using necessary bolts, nuts and washers.(P.No.21, I.No.5.48 in CSR Electrical SR Volume-6 2023-24)Each4988.294988.293.0FalseNoneNoneFalseNoneFalse14964.870
3300051115035Nonecode09Supply and fixing of Auxiliary contactor relay with 2 NO and 2 NC contact and operating coil voltage of 220V to 260V. fixed on existing wood/panel board using necessary bolts, nuts, washers and wiring etc.,(P.No.22, I.No.5.53 in CSR Electrical SR Volume-6 2023-24)Each1369.91369.93.0FalseNoneNoneFalseNoneFalse4109.70
3300052115035Nonecode10Supplying and fixing of metal clad industrial plugs and sockets. (P.No.09, I.No.3.13.3 & 3.13.4 in CSR Electrical SR Volume-6 2023-24) 3pole+earth 440V PLUG-32 Amps 16 AmpsEach465.69465.692.0FalseNoneNoneFalseNoneFalse931.380
3300053115035Nonecode11Supplying and fixing of metal clad industrial plugs and sockets. (P.No.09, I.No.3.13.3 & 3.13.4 in CSR Electrical SR Volume-6 2023-24) 3pole+earth 440V PLUG-32 Amps 32 AmpsEach628.16628.162.0FalseNoneNoneFalseNoneFalse1256.320
3300054115035Nonecode12Supplying,fixing and wiring 0to30 A Direct Reading AC analog type Ammeter.(P.No.18, I.No.5.24 in CSR Electrical SR Volume-6 2023-24)Each478.95478.954.0FalseNoneNoneFalseNoneFalse1915.80
3300055115035Nonecode13Supplying,fixing and wiring 0 to 600 V 96x96mm AC Voltmeter on existing panel/wood board.(P.No.18, I.No.5.22 in CSR Electrical SR Volume-6 2023-24)Each465.56465.561.0FalseNoneNoneFalseNoneFalse465.560
3300056115035Nonecode14Supplying,fixing and wiring rotary selector switch suitable for Ammeter.(P.No.19, I.No.5.27 in CSR Electrical SR Volume-6 2023-24)Each206.0206.04.0FalseNoneNoneFalseNoneFalse824.00
3300057115035Nonecode15Supplying, fixing and wiring rotary selector switch suitable for Voltmeter.(P.No.19, I.No.5.28 in CSR Electrical SR Volume-6 2023-24)Each164.8164.81.0FalseNoneNoneFalseNoneFalse164.80
3300058115035Nonecode16Supplying,fixing and wiring 50/5 to 400/5A 5VA burden Current Transformer Class 0.5 accuracy with Tape Wound.(P.No.19, I.No.5.34 in CSR Electrical SR Volume-6 2023-24)Each578.86578.864.0FalseNoneNoneFalseNoneFalse2315.440
3300059115035Nonecode17Supplying and fixing digital frequency meter with latest micro controller technology,ultra bright 4digit LED display,from 30-500VAC and optional or relay output for high/low frequency and wiringcomplete.(P.No.19, I.No.5.32 in CSR Electrical SR Volume-6 2023-24)Each1004.251004.251.0FalseNoneNoneFalseNoneFalse1004.250
3300060115035Nonecode18Supplying,fixing and wiring heavy duty low voltage capacitors conforming to IS2834.3 phase,400/440V grade,for power factor improvement of rotating machineries like induction motor.(P.No.19, I.No.5.37 in CSR Electrical SR Volume-6 2023-24)Each494.4494.45.0FalseNoneNoneFalseNoneFalse2472.00
3300061115035Nonecode19Supply & laying 1.1kV LT UG cable XLPE / heat resistant PVC insulated, PVC extruded inner sheath armoured as per IS:1554 part-1 or IS:7098 part-1, Armouring thickness +5% and resistivity 14 Ohms /Kms Max as per IS: 3975. Glands & Lugs not included. 50 Sqmm, 3.5 Core, (16 GI Strips - 4 x 0.8 mm) .ESCOM SR 2023-24, P.No.13. I No. 32.11Km184342.19184342.190.03FalseNoneNoneFalseNoneFalse5530.26570
3300062115035Nonecode20Supply & laying 1.1kV LT UG cable XLPE / heat resistant PVC insulated, PVC extruded inner sheath armoured as per IS:1554 part-1 or IS:7098 part-1, Armouring thickness +5% and resistivity 14 Ohms /Kms Max as per IS: 3975. Glands & Lugs not included. 4Cx25 Sqmm Al Ar cable.ESCOM SR 2023-24, P.No.13 I No. 32.08Km185239.32185239.320.02FalseNoneNoneFalseNoneFalse3704.78640
3300063115035Nonecode21Supply & laying 1.1kV LT UG cable XLPE / heat resistant PVC insulated, PVC extruded inner sheath armoured as per IS:1554 part-1 or IS:7098 part-1, Armouring thickness +5% and resistivity 14 Ohms /Kms Max as per IS: 3975. Glands & Lugs not included. 4Cx16 Sqmm Al Ar cable.ESCOM SR 2023-24 I No. 32.05 Pg.13Km146097.26146097.260.02FalseNoneNoneFalseNoneFalse2921.94520
3300064115035Nonecode22Supply & laying 1.1kV LT UG cable XLPE / heat resistant PVC insulated, PVC extruded inner sheath armoured as per IS:1554 part-1 or IS:7098 part-1, Armouring thickness +5% and resistivity 14 Ohms /Kms Max as per IS: 3975. Glands & Lugs not included. 4Cx10 Sqmm Cu Ar cable.ESCOM SR 2023-24 I No. 32.03 Pg.13Km121544.12121544.120.02FalseNoneNoneFalseNoneFalse2430.88240
3300065115035Nonecode23Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff.(P.No.52,I.No.21.05 &21.06 of 2023-24 PWD Electrical Volume-6 SR) LT Cable-2.5 to 25 SqmmKm21512.5821512.580.05FalseNoneNoneFalseNoneFalse1075.6290
3300066115035Nonecode24Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff.(P.No.52,I.No.21.05 &21.06 of 2023-24 PWD Electrical Volume-6 SR) LT Cable-35 to 95 SqmmKm32073.1732073.170.03FalseNoneNoneFalseNoneFalse962.19510
3300067115035Nonecode25Earth Work Excavation for pipeline/cables by manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shorting, strutting,barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting and stacking the selected earth for reuse in a redius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth sides of foundations etc.. in layers not exceeding 20 cm in depth, consolidated each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work.(P.No.06, I.No 1.6.1 in KPWD CSR volume-1, 2023-24Cum498.52498.526.75FalseNoneNoneFalseNoneFalse3365.010
3300068115035Nonecode26Supply & installation of LT Cables End termination - Heavyduty cable Glands suitable for UG cable of 1.1kV Class. 3.5Cx50 Sqmm Al Ar cable.ESCOM SR 2023-24 I No. 22.14 Pg.53No195.7195.72.0FalseNoneNoneFalseNoneFalse391.40
3300069115035Nonecode27Supply & installation of LT Cables End termination - Heavyduty cable Glands suitable for UG cable of 1.1kV Class. 2.5 to 25 sqmm. .ESCOM SR 2023-24 I No. 22.13 Pg.53 ESCOM SR 2023-24 I No. 22.13 Pg.53No96.8296.8212.0FalseNoneNoneFalseNoneFalse1161.840
3300070115035Nonecode28Supplying & Fixing heavey guage PVC conduit type 2mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc, and shall be concealed in wall/RCC slab or exposed on fixing invrted wood plugs in case of RCC ceiling and RCC wall/stone structure or rawl plugs in case of brick wall & cement plastering the damaged portion using heavy gauage saddles at interval of 700mm using NF screws. 19/20mm dia PVC 2mm thick conduit.PWD Electrical SR-2023-24, ITEM NO:1.1.1 ,CH-1, PAGE NO-2Mtr71.0771.0725.0FalseNoneNoneFalseNoneFalse1776.750
3300071115035Nonecode29Supplying & Fixing heavey guage PVC conduit type 2mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc, and shall be concealed in wall/RCC slab or exposed on fixing invrted wood plugs in case of RCC ceiling and RCC wall/stone structure or rawl plugs in case of brick wall & cement plastering the damaged portion using heavy gauage saddles at interval of 700mm using NF screws. 25mm dia PVC 2mm thick conduit.PWD Electrical SR-2023-24, ITEM NO:1.1.2 ,CH-1, PAGE NO-2Mtr83.4383.4325.0FalseNoneNoneFalseNoneFalse2085.750
3300072115035Nonecode30Supplying & Fixing heavey guage PVC conduit type 2mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc, and shall be concealed in wall/RCC slab or exposed on fixing invrted wood plugs in case of RCC ceiling and RCC wall/stone structure or rawl plugs in case of brick wall & cement plastering the damaged portion using heavy gauage saddles at interval of 700mm using NF screws. 32mm dia PVC 2.5mm thick conduit.PWD Electrical SR-2023-24, ITEM NO:1.1.3 ,CH-1, PAGE NO-22Mtr109.18109.1820.0FalseNoneNoneFalseNoneFalse2183.60
3300073115035Nonecode31Supplying & Fixing heavey guage PVC conduit type 2mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc, and shall be concealed in wall/RCC slab or exposed on fixing invrted wood plugs in case of RCC ceiling and RCC wall/stone structure or rawl plugs in case of brick wall & cement plastering the damaged portion using heavy gauage saddles at interval of 700mm using NF screws. 40mm dia PVC 2.5mm thick conduit.PWD Electrical SR-2023-24, ITEM NO:1.1.4 ,CH-1, PAGE NO-2Mtr153.47153.4720.0FalseNoneNoneFalseNoneFalse3069.40
3300074115035Nonecode32Supplying and wiring adopting loop system in existing PVC Conduit/casing capping using 2x1.5 Sqmm (Phase&Neutral) & 1x1.0sqmm (Earthwire) FRLS multistrand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6 Amps flush type SP control switch shall be fixed on the existing plastic sheet/gangbox,the other end of the wires shall be terminated with sufficient loose length in a wood/PVCround block.complete for each outlet. Short point upto 3Mtr from tapping point to out let via switch.PWD Electrical SR-2023-24, ITEM NO:2.1.1 ,CH-1, PAGE NO-5No293.55293.5510.0FalseNoneNoneFalseNoneFalse2935.50
3300075115035Nonecode33Supplying and wiring adopting loop system in existing PVC Conduit/casing capping using 2x1.5 Sqmm (Phase&Neutral) & 1x1.0sqmm (Earthwire) FRLS multistrand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6 Amps flush type SP control switch shall be fixed on the existing plastic sheet/gangbox,the other end of the wires shall be terminated with sufficient loose length in a wood/PVCround block.complete for each outlet. Medium point above 3 Mtr upto 6 Mtr from tapping point to outlet via switch.PWD Electrical SR-2023-24, ITEM NO:2.1.2 ,CH-1, PAGE NO-5No405.82405.8210.0FalseNoneNoneFalseNoneFalse4058.20
3300076115035Nonecode34Supplying and wiring adopting loop system in existing PVC Conduit/casing capping using 2x1.5 Sqmm (Phase&Neutral) & 1x1.0sqmm (Earthwire) FRLS multistrand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6 Amps flush type SP control switch shall be fixed on the existing plastic sheet/gangbox,the other end of the wires shall be terminated with sufficient loose length in a wood/PVCround block.complete for each outlet. Long point above 6 Mtr upto10Mtr from tapping point to outlet via switch PWD Electrical SR-2023-24, ITEM NO:2.1.3 ,CH-1, PAGE NO-5No587.1587.16.0FalseNoneNoneFalseNoneFalse3522.60
3300077115035Nonecode35Two outlet in a row,above 3 Mtr upto 6 Mtr from tapping point to outlet via switches..PWD Electrical SR-2023-24, ITEM NO:2.1.4 ,CH-1, PAGE NO-5No729.24729.245.0FalseNoneNoneFalseNoneFalse3646.20
3300078115035Nonecode36Three outlet in a row,above 6 Mts upto10 Mtr from tapping point to out let via switches.PWD Electrical SR-2023-24, ITEM NO:2.1.5 ,CH-1, PAGE NO-5No1066.051066.054.0FalseNoneNoneFalseNoneFalse4264.20
3300079115035Nonecode37Supply & wiring from distribution board to looping switch boards. Laid wire size 2x2.5 Sqmm Ph-N & 1x1.5Sqmm for E for Lighting circuit wiring laid in existing conduit. 1.0 Sqmm Cu FRLS wire.PWD Electrical SR-2023-24, ITEM NO:2.3.1 ,CH-1, PAGE NO-5Mtr19.5719.57200.0FalseNoneNoneFalseNoneFalse3914.00
3300080115035Nonecode38Supply & wiring from distribution board to looping switch boards. Laid wire size 2x2.5 Sqmm Ph-N & 1x1.5Sqmm for E for Lighting circuit wiring laid in existing conduit. 1.5 Sqmm Cu FRLS wire.PWD Electrical SR-2023-24, ITEM NO:2.3.2 ,CH-1, PAGE NO-5Mtr26.7826.78100.0FalseNoneNoneFalseNoneFalse2678.00
3300081115035Nonecode39Supply & wiring from distribution board to looping switch boards. Laid wire size 2x2.5 Sqmm Ph-N & 1x1.5Sqmm for E for Lighting circuit wiring laid in existing conduit. 2.5 Sqmm Cu FRLS wire.PWD Electrical SR-2023-24, ITEM NO:2.3.3 ,CH-1, PAGE NO-5Mtr43.2643.26150.0FalseNoneNoneFalseNoneFalse6489.00
3300082115035Nonecode40Supply & wiring from distribution board to looping switch boards. Laid wire size 2x2.5 Sqmm Ph-N & 1x1.5Sqmm for E for Lighting circuit wiring laid in existing conduit. 4.0 Sqmm Cu FRLS wire.PWD Electrical SR-2023-24, ITEM NO:2.3.4 ,CH-1, PAGE NO-5Mtr64.8964.8975.0FalseNoneNoneFalseNoneFalse4866.750
3300083115035Nonecode41Supply & wiring from distribution board to looping switch boards. Laid wire size 2x2.5 Sqmm Ph-N & 1x1.5Sqmm for E for Lighting circuit wiring laid in existing conduit. 6.0 Sqmm Cu FRLS wire.PWD Electrical SR-2023-24, ITEM NO:2.3.5 ,CH-1, PAGE NO-5Mtr94.7694.7650.0FalseNoneNoneFalseNoneFalse4738.00
3300084115035Nonecode42Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos.of machine screws, bolts nuts etc.,complete on the existing metal/PVC box.10 - 12 Way Polycarbonate switch box plate.PWD Electrical SR-2023-24, ITEM NO:3.5.6 ,CH-3, PAGE NO-8No354.32354.325.0FalseNoneNoneFalseNoneFalse1771.60
3300085115035Nonecode43Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos.of machine screws, bolts nuts etc.,complete on the existing metal/PVC box.10 - 12 Way Polycarbonate switch box plate.PWD Electrical SR-2023-24, ITEM NO:3.5.6 ,CH-3, PAGE NO-8 3 Module. PWD Electrical SR-2023-24, ITEM NO:3.5.2 ,CH-3, PAGE NO-8No165.83165.834.0FalseNoneNoneFalseNoneFalse663.320
3300086115035Nonecode44Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cuttingin Brick/C.C wall, including necessary rawl plugs,Machine/NF screws etc., complete. 3 Way PWD Electrical SR-2023-24, ITEM NO:3.3.2 ,CH-3, PAGE NO-8No127.72127.725.0FalseNoneNoneFalseNoneFalse638.60
3300087115035Nonecode45Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cuttingin Brick/C.C wall, including necessary rawl plugs,Machine/NF screws etc., complete. 10-12 Way PWD Electrical SR-2023-24, ITEM NO:3.3.6 ,CH-3, PAGE NO-8No268.83268.835.0FalseNoneNoneFalseNoneFalse1344.150
3300088115035Nonecode46Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.Switches & sockets outlets in Existing modular box, 6A one way switch.PWD Electrical SR-2023-24, ITEM NO:3.6.1 ,CH-3, PAGE NO-9No105.06105.064.0FalseNoneNoneFalseNoneFalse420.240
3300089115035Nonecode47Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.Switches & sockets outlets in Existing modular box, 6A 3 way socket.PWD Electrical SR-2023-24, ITEM NO:3.6.3 ,CH-3, PAGE NO-9No176.13176.134.0FalseNoneNoneFalseNoneFalse704.520
3300090115035Nonecode48Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.Switches & sockets outlets in Existing modular box, 6/16A Universal socket.PWD Electrical SR-2023-24, ITEM NO:3.6.10 ,CH-3, PAGE NO-9No243.08243.082.0FalseNoneNoneFalseNoneFalse486.160
3300091115035Nonecode49Supply of LED flood light luminaire with pressure die cast aluminium housing body for optimal thermal dissipation.Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate clear glass material delivering superior light output Rated life Burning Hrs 50000hr Lumen Maintenance of 70, CCT 5500K, IP66 optical and electrical compartment & impact resistance of complete luminaire IK08. PowerFactor 0.9 with mains, Surge Protection Min 5KV along with Over voltage /Overload, short circuit/ miss-wiring protection.Compatible for pole mauling with outer dia of 40 mm to 50mm.Universal Voltage driver to operate wide voltage range from 100 V to 270V 50/60 Hz application.Compliance to IS 10322/IEC60598 ,LM79 & LM80 Adherence with RoHS.UL approved MCPCB.Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools.LED Light fixture with W System Power consumption.LED Efficiency 1301m/w, nominal CRI75.Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008.Housing with supplier wordmark/name shall be Engraved/Embossing on the die cast housing/Body part Warranty of 2 Years against any manufacturing defect working understand ard electrical conditions as mentioned above should be given by LED manufacturer &Cree/Nichia/Lumileds/Osram make LED Source.-LED Floodlight 100W. (PWD Electrical SR-2023-24, ITEM NO:11.9.2, PAGE NO-46No9770.589770.5810.0FalseNoneNoneFalseNoneFalse97705.80
3300092115035Nonecode50GI/Copper strips for grounding connections, using necessary fixing materials as required.25x6mm GI Earth Strip.PWD Electrical SR-2023-24, ITEM NO:12.58.2 ,CH-12, PAGE NO-54Mtr84.4684.4640.0FalseNoneNoneFalseNoneFalse3378.40
3300093115035Nonecode512 mm thick perforated cable GI tray with one xisting MS angle support using necessary GI bolts/nuts and washer or welding as required.(PWD Electrical SR-2023-24, ITEM NO:12.59.2 ,CH-12, PAGE NO-55Mtr604.61604.6115.0FalseNoneNoneFalseNoneFalse9069.150
3300094115035Nonecode52Supplying,fixing,wiring,earth electrode for grounding conduits,I.C.cutouts and other equipment's on the meter board using 40mm dia 2.90mm thick GI pipe 2.5m long buried in a pit.The pit should be filled with equal proportion of salt and charcoal 150 mm all-round the pipe to complete depth.The connection from the pipe to the conduit etc.,is to be established through GIwire of size asper lSI specification 7.3.3.of IS 732 using 12mm dia bolts,nuts,washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia.PWD Electrical SR-2023-24, ITEM NO:12.56,CH-12, PAGE NO-54No3615.33615.32.0FalseNoneNoneFalseNoneFalse7230.60
3300095115035Nonecode 53Fabricating supplying and mounting MS box made out.SWG suitable for floor/wall mounting,fully weather proof with provision for better heat dissipation,provided with hinged front cover,equipped with tamper proof locking arrangements,with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7 tanks treatment with powder coated paint and finally finished with approved colour etc., complete.(P.No.20, I.No.5.42.1 in CSR Electrical SR Volume-6 2023-24)Sq CM0.520.5235000.0FalseNoneNoneFalseNoneFalse18200.00
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17186955370001NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17186955370001NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by any State Government / Government of India /Union TerritoryNone
17186955370001NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submissionNone
17186955370000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17186955370000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
17186960360000NoneNoneELIGIBILITYThe bidder is required to ensure browser compatibility of the computer well in advance to the last date and time for receipt of tenders. The departments shall not be responsible for non-accessibility of KPP portal due to internet connectivity issues and technical glitches at bidders endNone
17186960570000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejectionNone
17186960750000NoneNoneELIGIBILITYBidder shall pay Contract Management Module processing fees of 0.025% of the contact value (Min Rs.500/- & Max Rs.7500/-) soon after contract has been issued to bidderNone
17186960900000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender documentNone
17186961060000NoneNoneELIGIBILITYConditional tenders will not be acceptedNone
17186961220000NoneNoneELIGIBILITYTenderers are required to read the Bid Documents carefully before submission of their bidNone
17186961360000NoneNoneELIGIBILITYAny discrepancies observed in the documents uploaded by the tenderer the tender shall liable to rejectedNone
17186961770000NoneNoneELIGIBILITYRoyalty on construction materials and other taxes will be deducted as per prevailing Govt., orders as may be modified from time to timeNone
17186961960000NoneNoneELIGIBILITYAs per Karnataka State Government order No. LD/300/LET/2006 Bangalore Dated 01.01.2007 and Government Letter No.PW/134/BMS/2007 Dated 27-07-2007, a sum amounting to 1%of the bill amount will be deducted towards Construction Labour Welfare fundNone
17186962110000NoneNoneELIGIBILITYThe Tenderer shall scan Original Work done certificates / Turnover Statements and any other documents specified by the employer and attach the scanned file to the Bid. The Original Documents shall be produced for physical verification within one week from the date of Technical bid openingNone
17186962280000NoneNoneELIGIBILITYThe Employer reserves the right to reject any or all Tenders without assigning any reason or what so everNone
17186962460000NoneNoneELIGIBILITYThe earnest money deposit will be forfeited if the documents submitted by the tenderer found to be misleading/forged or fakeNone
17186962620000NoneNoneELIGIBILITYFinancial turnover of previous years shall be given a weightage of 10% per year to bring them to the price level of the 2024-25None
17186962820000NoneNoneELIGIBILITYBidder has to quote rates excluding GST, GST shall be paid separately for the applicableNone
17186962980000NoneNoneELIGIBILITYAll the Work done certificate uploaded should include E-procurement indent numberNone
17186963140000NoneNoneELIGIBILITYTurnover certificate from CA with valid UDIN No. to be furnished along with necessary documentsNone
17186963350000NoneNoneELIGIBILITYMethodology for execution of work should be submitted during technical bidNone
17186963580000NoneNoneELIGIBILITYOnly relevant documents should be submitted in e-procurementNone
17186963770000NoneNoneELIGIBILITYThe Bills will be paid as per grant released from the government time to timeNone
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneThe tenderer in its name should have in the last five years i.e., 2019-20 to 2023-24,The bidder should have Satisfactory completed, at least one Building works of value not less than Rs. 49.95 Lakhs as prime contractor In support of the above, work done certificate has to be duly certified by an officer not below the rank of Executive Engineer with indent numberPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneExecuted in one year the following minimum quantities of work signed by officer not below the rank of Executive Engineer 1.Earth work excavation/Embankment:497.49Cum, Cement concrete/RCC:192.24 cum, Size stone masonry:33.43cum, Concrete solid blocks:219.54 sqm, TMT steel:7.01 MT and structural steel:21808.00 kgs Galvanised iron profile sheets/ GI sheets/ AC sheets 1299.00 sqmCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneValid PWD CLASS III and above Contractor Registration certificate shall be furnished. not below the rank of SECapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNonePWD Registration Certificate (Class I/II/III/IV)
NoneNoneNoneNoneList of works for which tenders already submittedCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Tenders already submitted document
NoneNoneNoneNoneQualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awardedCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Technical and Management personnel in permanent employment details
NoneNoneNoneNoneThe tenderer in its name should have in the last five years i.e., 2019-20 to 2023-24 Achieved in at least two financial years a minimum annual financial turnover of Rs.99.90 Lakhs Turnover certificate from CA with valid UDIN No. to be furnished along with necessary documentsFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNoneLiquid assets and or availability of credit facilities of not less than Rs. 30.00 Lakhs Credit lines/ letters of credit/ certificates from banks for meeting the fund requirement etc from nationalized/schedule bankFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneLine of Credit
NoneNoneNoneNoneReports on the financial standing of the tenderer, such as profit and loss statements and auditors reports for the last five years from 2019-20 to 2023-24Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneITR Filed Copy (Mentioning PAN)
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid Electrical License for executing building electrification works and should have executed similar electrical works totalling Rs. (not less than 50% of electrical works) n any one yearOthersNot Mandatory
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Not mandatory
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid license for executing water supply / sanitary engineering works and should have executed similar works totalling Rs. (not less than 50% of electrical works) n any one yearOthersNot Mandatory
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Not mandatory
NoneNoneNoneNoneOwning the following key and critical equipment for this work Deleted as per Circular No.FD.263 Cost-12/2022. Date: 11-05-2022OthersNot Mandatory
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Not mandatory
NoneNoneNoneNoneConcrete rates including cost of form work and and excluding reinforcement costOthersTechnical criteria
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Technical Criteria
NoneNoneNoneNoneBanker Details for referenceOthersNot Mandatory
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Not mandatory
NoneNoneNoneNoneConstruction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awarded Deleted as per Circular No.FD.263 Cost-12/2022. Date: 11-05-2022OthersNot Mandatory
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Not mandatory
NoneNoneNoneNoneList of Financial Resources with CertificatesOthersNot Mandatory
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Not mandatory
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Valid PWD CLASS III and above Contractor Registration certificate shall be furnished. not below the rank of SETrueTechnical Bid
The tenderer in its name should have in the last five years i.e., 2019-20 to 2023-24 Achieved in at least two financial years a minimum annual financial turnover of Rs.99.90 Lakhs Turnover certificate from CA with valid UDIN No. to be furnished along with necessary documentsTrueTechnical Bid
Satisfactory completed, at least one Building works of value not less than Rs. 49.95 Lakhs as prime contractor In support of the above, work done certificate has to be duly certified by an officer not below the rank of Executive Engineer with indent numberTrueTechnical Bid
Executed in one year the following minimum quantities of work signed by officer not below the rank of Executive Engineer 1.Earth work excavation/Embankment 492.00Cum, Cement concrete/RCC 192.24 cum, Size stone masonry 33.43cum, Concrete solid blocks 219.54 sqm, TMT steel 7.01 MT and structural steel 21808.00 kgsTrueTechnical Bid
Liquid assets and or availability of credit facilities of not less than Rs. 30.00 Lakhs Credit lines/ letters of credit/ certificates from banks for meeting the fund requirement etc from nationalized/schedule bankTrueTechnical Bid
GST Registration CertificateTrueTechnical Bid
List of existing commitments and ongoing worksTrueTechnical Bid
Qualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awardedTrueTechnical Bid
In accordance with the statutory requirements applicable to Karnataka minimum of Rs. 5 lakh per person and insurance shall cover minimum 4 personsTrueTechnical Bid
tenderWorkLocationList
tenderAddress
createdTs1718706597000
version0
createdDateNone
modifiedDateNone
blockNumberCity Municipal Office, M.G Road, Kanakapura, Ramanagara (Dist)
streetNone
cityKanakapura
stateKarnataka
pin562117
tenderRecallDTONone