createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1718596916805
version2
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeONE_COVER
evaluationTypeTextOne Cover
invitingStrategyRESERVED
invitingStrategyTextReserved
taxTypeINCLUSIVE_TAX
tenderFee500.00
emd17380.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose26-06-2024 17:00:00
tenderQueryClose25-06-2024 17:00:00
technicalBidOpenNone
publishedDate19-06-2024 13:38:48
publishedByPostRDPR_EE_DIV_VJN
publishedByUserKPE12111 - J R PAMPAPATHI
bidValidityPeriod90
noOfCalls1
preBidMeetingDateNone
preBidMeetingYnFalse
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonEE OFFICE
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedNone
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumberNone
mobileNumber9482100616
tenderSupplierListNone
tenderSchedule
createdTs1718596916850
version4
createdDateNone
modifiedDateNone
tenderNumberRDPR/2024-25/BD/WORK_INDENT5933
titleConstruction of 1 school room for Govt Junior Primary School of Harapanahalli Taluk Anemagala Tanda Village (Ragi Masalawada Gram Panchayat) (SC Reserved)
descriptionConstruction of 1 school room for Govt Junior Primary School of Harapanahalli Taluk Anemagala Tanda Village (Ragi Masalawada Gram Panchayat) (SC Reserved)
categoryWORKS
categoryTextWorks
ecv1370600.24
deptNameRural Development and Panchayat Raj Department
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnTrue
location943
locationNameRDPR Division Office Vijayanagara
provisionalAmount1390000.0
groupOverheadTotal209074.61
fileNumberPREDSD/HRP/2023-24/DMF/35
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17185969170000NoneNoneBuildingsConstruction of 1 school room for Govt Junior Primary School of Harapanahalli Taluk Anemagala Tanda Village (Ragi Masalawada Gram Panchayat) (SC Reserved)1161525.63
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3298380114950Nonecode01Banagere GUHPS Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work.Cum254.1254.139.32FalseNoneNoneFalseNoneFalse9991.2120
3298381114950Nonecode02Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) - Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregatesCum6288.456288.459.99FalseNoneNoneFalseNoneFalse62821.61550
3298382114950Nonecode03Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)Cum6708.456708.4514.95FalseNoneNoneFalseNoneFalse100291.32750
3298383114950Nonecode04Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) - Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates (It.No.2.1.3 Page.no.15)Cum6527.856527.851.1FalseNoneNoneFalseNoneFalse7180.6350
3298384114950Nonecode05Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum279.3279.332.86FalseNoneNoneFalseNoneFalse9177.7980
3298385114950Nonecode06Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of workCum8367.458367.4516.03FalseNoneNoneFalseNoneFalse134130.22350
3298386114950Nonecode07Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) - M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum6601.356601.354.92FalseNoneNoneFalseNoneFalse32478.6420
3298387114950Nonecode08Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) - M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum7185.157185.1520.18FalseNoneNoneFalseNoneFalse144996.3270
3298388114950Nonecode09Providing Thermo-Mechanically Treated bars of grade Fe-550 or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately)Kg93929.8593929.852.28FalseNoneNoneFalseNoneFalse214160.0580
3298389114950Nonecode10Form work, centering and scaffolding for FoundationCum198.04198.044.92FalseNoneNoneFalseNoneFalse974.35680
3298390114950Nonecode11Form work, centering and scaffolding for Columns & PiersCum5029.615029.614.14FalseNoneNoneFalseNoneFalse20822.58540
3298391114950Nonecode12Form work, centering and scaffolding for Chejja, Canopy and other Architectural projections of minor sections.Cum3233.323233.320.14FalseNoneNoneFalseNoneFalse452.66480
3298392114950Nonecode13Form work, centering and scaffolding for Beams & Lintels of BuildingCum4311.094311.094.55FalseNoneNoneFalseNoneFalse19615.45950
3298393114950Nonecode14Form work, centering and scaffolding for Roof (Straight & Arched) of BuildingCum3592.583592.5811.35FalseNoneNoneFalseNoneFalse40775.7830
3298394114950Nonecode15Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm309.75309.7569.86FalseNoneNoneFalseNoneFalse21639.1350
3298395114950Nonecode16Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-chargeSqm404.25404.25156.79FalseNoneNoneFalseNoneFalse63382.35750
3298396114950Nonecode17Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.Sqm105.0105.051.66FalseNoneNoneFalseNoneFalse5424.30
3298397114950Nonecode18Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Sqm4701.94701.92.21FalseNoneNoneFalseNoneFalse10391.1990
3298398114950Nonecode19Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Kg155.4155.4172.8FalseNoneNoneFalseNoneFalse26853.120
3298399114950Nonecode20Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by weldingKg176.4176.4136.08FalseNoneNoneFalseNoneFalse24004.5120
3298400114950Nonecode21Flooring with 25mm thick polished tandur blue stone slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab, , including cost of materials, labour, curing, polishing complete as per specifications.Kg1622.251622.2553.24FalseNoneNoneFalseNoneFalse86368.590
3298401114950Nonecode22Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacturer, in all colours and shade, in skirting, riser, treads of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints as per direction of Engineer in charge.Sqm1231.651231.653.07FalseNoneNoneFalseNoneFalse3781.16550
3298402114950Nonecode23Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm143.85143.85125.86FalseNoneNoneFalseNoneFalse18104.9610
3298403114950Nonecode24Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm93.4593.45161.13FalseNoneNoneFalseNoneFalse15057.59850
3298404114950Nonecode25Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm120.75120.7517.52FalseNoneNoneFalseNoneFalse2115.540
3298405114950Nonecode26Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Kg142.8142.8106.68FalseNoneNoneFalseNoneFalse15233.9040
3298406114950Nonecode27Supplying UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. for: Pipes of SN4, 110mm dia.Mtr302.4302.46.0FalseNoneNoneFalseNoneFalse1814.40
3298407114950Nonecode28Cement BoardSqm308.7308.72.88FalseNoneNoneFalseNoneFalse889.0560
3298408114950Nonecode29Providing and fixing board displaying information, such as 'Name of work, Tender cost, Name of Contractor, Work completion and liability period etc', having rectangular shape of 1.20m x 0.90m size made out 18 gauge (1.25mm) thick mild steel sheet painted with one coat of Zinc chromate stoving primer and two coats of enamel paint on front side and grey stove enamel on back side and border / messages / symbols etc. with approved colour shade paint complete, on M.S.angle of size 35 x 35 x 3 mm frame with properly cross braced M.S. angles of size 35mmx35mmx3mm duly painted including Two M.S. angle iron posts of size 65 mm x 65 mm x 6 mm, 3.65 m long painted with alternate black and white bands of 25 cm width including all fixtures etc.and fixing the boards in 1:4:8 concrete block of size 60 cm x 60 cm x 75 cm including, excavation, refilling, transportation, and labour etc complete. Spec. No. As directed by Engineer in Charge & MoRTH specification 804Nos9450.09450.01.0FalseNoneNoneFalseNoneFalse9450.00
3298409114950Nonecode30Concealed Conduit System : Supplying heavy gauge PVC conduit pipe ...... mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessaryMtr78.078.030.0FalseNoneNoneFalseNoneFalse2340.00
3298410114950Nonecode31Supplying heavy gauge PVC Conduit Pipe .... dia ....... mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary.Mtr79.079.040.0FalseNoneNoneFalseNoneFalse3160.00
3298411114950Nonecode32Supplying and fixing sheet Metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc..- 180x90x65mmNos161.0161.01.0FalseNoneNoneFalseNoneFalse161.00
3298412114950Nonecode33Supplying and flush mounting teak wooden box without front plank, made of not less than 12 mm thick wood, after due groove cutting, finishing with necessary cement plastering complete.(300x300x76mm)Mtr120.0120.01.0FalseNoneNoneFalseNoneFalse120.00
3298413114950Nonecode34Supplying of .....feet -PVC Batten with integrated LED tube .... W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V@ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manmanufacturing defect working under standard electrical condition. LED light fitting 1 x 4' - 20/22 WNos690.0690.03.0FalseNoneNoneFalseNoneFalse2070.00
3298414114950Nonecode35Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system - 48" Sweep (1200mm) Regular modelNos2984.02984.02.0FalseNoneNoneFalseNoneFalse5968.00
3298415114950Nonecode36Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point upto 3Mtr from tapping point to out let via switchPoint285.0285.02.0FalseNoneNoneFalseNoneFalse570.00
3298416114950Nonecode37Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Medium point above 3Mtr upto 6Mtr from tapping point to out let via switchPoint394.0394.02.0FalseNoneNoneFalseNoneFalse788.00
3298417114950Nonecode38Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Long point above 6Mtr upto 10Mtr from tapping point to out let via switchPoint570.0570.01.0FalseNoneNoneFalseNoneFalse570.00
3298418114950Nonecode39Supplying 6A flush type socket and 6 A flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3654 - 6Amps 3/5 WayNos147.0147.06.0FalseNoneNoneFalseNoneFalse882.00
3298419114950Nonecode40Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.Nos739.0739.01.0FalseNoneNoneFalseNoneFalse739.00
3298420114950Nonecode41Dismantling tile work in floors and roofs laid in cement mortar including stacking material to the appropriate disposal area as per direction of Engineer-in-charge - For thickness of tiles 10 mm to 25 mmSqm50.450.439.66FalseNoneNoneFalseNoneFalse1998.8640
3298421114950Nonecode42Demolishing cement concrete manually/ by mechanical means including disposal of material to the appropriate disposal area as per direction of Engineer-in-charge.Cum1746.151746.153.97FalseNoneNoneFalseNoneFalse6932.21550
3298422114950Nonecode43Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge.Cum2547.32547.37.36FalseNoneNoneFalseNoneFalse18748.1280
3298423114950Nonecode44Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge.Cum1080.451080.4513.05FalseNoneNoneFalseNoneFalse14099.87250
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17185969180000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17185969180000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17185969180000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17185969180000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17185969180000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
17185969330000NoneNoneELIGIBILITYThe Employer reserves the right to reject any or all Tenders without assigning any reason.None
17185969400000NoneNoneELIGIBILITYCorrigendum modifications correction, if any, will be published in the website only,None
17185969550000NoneNoneELIGIBILITYDefect liability period will be one yearNone
17185969700000NoneNoneELIGIBILITYTo qualify for award of this contract, each Tenderer in his name should have in the last five years i.e 2019-20 to 2023-24 a. Achieved in at least ONE financial years a minimum financial turnover in all classes of civil engineering construction works only of Amount Put Tender (Turn over With compulsory UDIN Number)None
17185969760000NoneNoneELIGIBILITYTo qualify for award of this contract, each Tenderer in his name should have in the last five years i.e 2019-20 to 2023-24 b. Satisfactorily completed, as prime contractor, at least one similar work of value not less than 25% of the amount put tender (Workdone with indent No)None
17185969840000NoneNoneELIGIBILITYIf the tenderer has quoted below the schedule-B amount the difference amount should be paid in the form of F.D.R or D.D (As per G.O) in the name of Executive Engineer, PRE Division, Vijayanagara Hosapete from Nationalized Bank only and Upload the scanned copy of the same in e-portal at the time of applying the tender The Same Scanned copy for Different work will be liable for RejectionNone
17185969910000NoneNoneELIGIBILITYWork completion period will be 6 monthsNone
17185969970000NoneNoneELIGIBILITYThis work Reserved for SC Bidders onlyNone
17185970050000NoneNoneELIGIBILITYThe bidders are instructed to visit the site before submitting the bid and copy of the site visit certificate has to be obtained by the concerned AEE and the same has to be uploaded in Karnataka Public Procurement Portal (KPPP) If not submitting the site visiting letter otherwise bid will be not consideredNone
17185970110000NoneNoneELIGIBILITYAll other conditions and requirements has to be fulfilled as per the standard bid document and attached General conditionsNone
preQualCriterionListNone
technicalCriterionListNone
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Valid PWD Registration copyTrueTechnical Bid
Similar Nature Work done certificate with eproc Indent NoTrueTechnical Bid
Last 5 years Audit Report with UDIN NoTrueTechnical Bid
Difference Amount DD or FDR Scanned copyTrueTechnical Bid
Submit the Site visiting letter from concerned AEETrueTechnical Bid
Ongoing commitments and other standerd bid documentsTrueTechnical Bid
SC Caste certificate with RD NoTrueTechnical Bid
tenderWorkLocationList
tenderSubEstimateNamedistrictNametaluqNameloksabhaContNameassemblyContNamelocationDescriptionlatitudeDegreeslatitudeMinuteslatitudeSecondslongitudeDegreeslongitudeMinuteslongitudeSeconds
BuildingsVijayanagaraHarapanahalliDavangereHARAPANAHALLI (SC)Anemegala thandaNoneNoneNoneNoneNoneNone
tenderAddressNone
tenderRecallDTONone