tenderSubEstimateList | createdTs | version | createdDate | modifiedDate | workCategoryName | subEstimateName | estimateTotal | itemList |
---|
1717997961000 | 1 | None | None | Buildings | WATER SUPPLY FOR TOILET | 357597.95 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3253836 | 112721 | None | PWD SR VOL II 2023-24. I. No. 13.34 P.NO.123 | WATER SUPPLY WORKS
P/F STORAGE TANK
Providing and placing on terrace (on all floor levels), polyethylene water storage tanks IS: 12701 marked, with cover and suitable locking arrangements and making necessary holes for inlet, outlet and over flow pipes but without fittings and the base support for tank
| Ltr | 9.45 | 9.45 | 2000.0 | False | None | None | False | None | False | 18900.0 | 0 | 3253837 | 112721 | None | PWD SR VOL II 2023-24. I. No. 13.34 P.NO.123 | P/F STORAGE TANK
Providing and placing on terrace (on all floor levels), polyethylene water storage tanks IS: 12701 marked, with cover and suitable locking arrangements and making necessary holes for inlet, outlet and over flow pipes but without fittings and the base support for tank
| Ltr | 9.45 | 9.45 | 1000.0 | False | None | None | False | None | False | 9450.0 | 0 | 3253838 | 112721 | None | PWD SR VOL II 2023-24. I. No. 13.33.5 P.NO.123 | Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS 15778 having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, this includes jointing of pipes and fittings with one step solvent cement, trenching, refilling & testing of joints complete. (external work).
| Mtr | 500.85 | 500.85 | 15.0 | False | None | None | False | None | False | 7512.75 | 0 | 3253839 | 112721 | None | PWD SR VOL II 2023-24. I. No. 13.33.4 P.NO.122 | Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, this includes jointing of pipes and fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete. (external work). - 32mm nominal doa pipes
| m | 390.6 | 390.6 | 15.0 | False | None | None | False | None | False | 5859.0 | 0 | 3253840 | 112721 | None | PWD SR VOL II 2023-24. I. No. 13.32.3 P.NO.122 | Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, i/c including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes and fittings with one step solvent cement & the cost of cutting chases and making good the same including testing of joints complete as per direction of engineer in charge. concealed work, including cutting chases and making good the walls etc. - 25mm nominal dia pipes
| m | 500.85 | 500.85 | 15.0 | False | None | None | False | None | False | 7512.75 | 0 | 3253841 | 112721 | None | PWD SR VOL II 2023-24. I. No. 13.32.2 | Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, i/c including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes and fittings with one step solvent cement & the cost of cutting chases and making good the same including testing of joints complete as per direction of engineer in charge. concealed work, including cutting chases and making good the walls etc. - 20mm nominal dia pipes
| m | 397.95 | 397.95 | 15.0 | False | None | None | False | None | False | 5969.25 | 0 | 3253842 | 112721 | None | PWD SR VOL II 2023-24. I. No. 13.2.1 P.NO.117 | P/F BRASS BIBCOCK
| Nos | 300.3 | 300.3 | 15.0 | False | None | None | False | None | False | 4504.5 | 0 | 3253843 | 112721 | None | PWD SR VOL II 2023-24. I. No. 13.5.2 | P/F BRASS BALL VALVE
| Nos | 329.7 | 329.7 | 10.0 | False | None | None | False | None | False | 3297.0 | 0 | 3253844 | 112721 | None | PWD SR VOL II 2023-24. I. No. 14.7.2 | P/F WASH BASIN
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a single 15mm C.P. brass pillar tap
| Each | 2689.05 | 2689.05 | 4.0 | False | None | None | False | None | False | 10756.2 | 0 | 3253845 | 112721 | None | PWD SR VOL II 2023-24. I. No. 13.8.2.2 | PVC connection pipe
| Nos | 115.5 | 115.5 | 4.0 | False | None | None | False | None | False | 462.0 | 0 | 3253846 | 112721 | None | PWD SR VOL II 2023-24. I. No. 14.3.2 Page No. 131 | SANITARY WORK
WATER CLOSET
Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid
| Each | 6095.25 | 6095.25 | 16.0 | False | None | None | False | None | False | 97524.0 | 0 | 3253847 | 112721 | None | PWD SR VOL II 2023-24. No. 14.29 Page No. 136 | GULLY TRAP
| Each | 49.35 | 49.35 | 10.0 | False | None | None | False | None | False | 493.5 | 0 | 3253848 | 112721 | None | PWD CSR VOL I 2023-24I. No. 1.6.1 Page No.6 | EARTH WORK EXCAVATION
Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work. In all kinds of soils. Depth upto 1.50m
| Cum | 508.2 | 508.2 | 46.08 | False | None | None | False | None | False | 23417.856 | 0 | 3253849 | 112721 | None | WS&UGD CSR 2023-24 I.No.16.9 SOR CODE: T130B P.No. | BRICK MASONRY FOR INSPECTION CHAMBER
Constructing brick masonry chamber of internal dimension 600x600 mm and depth of 600 mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150 mm thick with 1:3:6, lastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75 mm thick for fixing CI cover & frame etc. excluding the cost of CI frame and cover.
| Each | 5726.7 | 5726.7 | 1.09 | False | None | None | False | None | False | 6242.103 | 0 | 3253850 | 112721 | None | WS &UGD CSR 2023-24. No16.1.2 P.No.184 | P/F STONEWARE PIPE
Supplying, lowering, laying, jointing, testing and commissioning of Glazed Stone Ware Pipes of following dia, conforming to IS 651:1992, IS 4127 with latest amendments, including conveying to work site, caulking with hemp dipped in tar and jointing with CM 1:1.5 using OPC, perfect linking and curing for 10 days and testing with water etc. with all lead, lifts and as per Technical Specifications. The cost to include the cost of all jointing materials, necessary survey works for laying of sewer lines etc. complete. The contractor will make own arrangements for procuring water for testing. 150 mm dia. pipes
| m | 610.05 | 610.05 | 10.0 | False | None | None | False | None | False | 6100.5 | 0 | 3253851 | 112721 | None | WS &UGD CSR 2023-24. No 16.5.1 SOR CODE: T070A P.N | Labour charges for laying and jointing glazed stone ware pipes of 0.6m length and of specified dia., of tested quality conforming to IS 651 of 1965 including caulking with hemp yarn, jointing with CM 1:2 and testing with water etc. complete for: (Rate to include cost of jointing materials and
trasportation of pipes from store work site ) | m | 74.55 | 74.55 | 10.0 | False | None | None | False | None | False | 745.5 | 0 | 3253852 | 112721 | None | WS &UGD CSR 2023-24. I.No.10.1.7 P.No.113 | Supplying PVC ring tight pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials)with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: PVC pipes 110 mm outer dia., 6 kg/sqcm & class 3
| m | 413.7 | 413.7 | 30.0 | False | None | None | False | None | False | 12411.0 | 0 | 3253853 | 112721 | None | PWD CSR VOL I 2023-24 I. No.2.1.2 P.No.15 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates
| Cum | 5947.2 | 5947.2 | 2.0 | False | None | None | False | None | False | 11894.4 | 0 | 3253854 | 112721 | None | PWD SR VOL II 2023-24 I.No. 6.8 P.No.14 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.
| Cum | 8367.45 | 8367.45 | 8.92 | False | None | None | False | None | False | 74637.654 | 0 | 3253855 | 112721 | None | PWD SR VOL II 2023-24 I. No.6.13 P.No.14 | Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:4 (1 cement :4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.
| Sqm | 1024.8 | 1024.8 | 5.4 | False | None | None | False | None | False | 5533.92 | 0 | 3253856 | 112721 | None | PWD CSR VOL I 2023-24, I. No. 2.3.1 P.No.16 | Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
| Cum | 7966.98 | 7966.98 | 1.51 | False | None | None | False | None | False | 12030.1398 | 0 | 3253857 | 112721 | None | PWD SR VOL II 2023-24, I. No. 8.8 P.No.42 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 486.94 | 486.94 | 36.4 | False | None | None | False | None | False | 17724.616 | 0 | 3253858 | 112721 | None | PWD SR VOL II2023-24. I. No. 13.40 | Providing & Fixing square - mouth S.W. guly trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I cover 180x150 mm size P type & with non-modular common burnt clay bricks of designation 3.5 & frame of 300 x 300mm size (inside) the weight of cover to be not less than4.50 kg and frame to be not less than 2.70 Kg as per standard design :
| Each | 2820.3 | 2820.3 | 1.0 | False | None | None | False | None | False | 2820.3 | 0 | 3253859 | 112721 | None | PWD SR VOL I 2023-24, I. No. 2.11a P.No.18 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, achinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire /soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.
| Tonne | 93929.85 | 93929.85 | 0.1 | False | None | None | False | None | False | 9392.985 | 0 | 3253860 | 112721 | None | PWD CSR VOL I 2023-24, I. No.6 P.No.111 | Additionalities for Formwork, Centering & Scaffolding 20% of I.No. 21
| Cum | 1593.4 | 1593.4 | 1.51 | False | None | None | False | None | False | 2406.034 | 0 |
| 1717997961000 | 1 | None | None | Buildings | WATER SUMP | 99845.35 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3253861 | 112722 | None | PWD SR VOL I 2023-24 I.No.1.5.2 P.No.6 | Earth work excavation by manual means for drains,canals, waste weir draft, approach channels, key trench, foundation of Bridges and such similar works, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, excavatedsurface leveled and sides neatly dressed disposing off or leveling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour,
| Cum | 467.25 | 467.25 | 1.88 | False | None | None | False | None | False | 878.43 | 0 | 3253862 | 112722 | None | PWD SR VOL I 2023-24 I.No.1.12 P.No.6 | Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth
not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps
and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. | Cum | 99.75 | 99.75 | 56.25 | False | None | None | False | None | False | 5610.9375 | 0 | 3253863 | 112722 | None | PWD SR VOL I 2023-24 I.No.2.1.2 P.No.15 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness,well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formworkshall be paid separately)
| Cum | 5947.2 | 5947.2 | 1.25 | False | None | None | False | None | False | 7434.0 | 0 | 3253864 | 112722 | None | PWD DSR 2023-24 vol-1 I.No.2.2.3 P No.15 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6652.8 | 6652.8 | 7.55 | False | None | None | False | None | False | 50228.64 | 0 | 3253865 | 112722 | None | PWD SR VOL I 2023-24, I. No. 2.11a P.No.18 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.
| Tonne | 93929.85 | 93929.85 | 0.38 | False | None | None | False | None | False | 35693.343 | 0 |
| 1717997961000 | 1 | None | None | Buildings | PUMPING MACHINARY | 83381.55 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3253866 | 112723 | None | WS & UGD Vol V CSR-2023-24 No.13.11.3 P No-151 | Providing,supplying to work site, Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications,as per necessary ammendments and instructions of engineer incharge of work. For 3 HP
| Each | 27205.5 | 27205.5 | 1.0 | False | None | None | False | None | False | 27205.5 | 0 | 3253867 | 112723 | None | WS & UGD -Vol V CSR - 2023-24 i. No. 13.22.3 ,P | Submersible Cables:
Supply and delivery at site Brand new best make PVC insulated cable of Flat 3 core (sheathed) of nominal cross sectional area as per IS 694-1990 with ISI Mark and as per its latest amendments. (1X3X4 m2)
| Mtr | 141.75 | 141.75 | 90.0 | False | None | None | False | None | False | 12757.5 | 0 | 3253868 | 112723 | None | WS & UGD -Vol V CSR -2023-24 I.No. 13.23.1 ,P N | Pressure Guage:
Supply and delivery at site of brand new best make pressure gauge bourdon type as per IS 778/1984 with ISI Mark and as per its latest amendments. a.63mm
| Each | 436.8 | 436.8 | 1.0 | False | None | None | False | None | False | 436.8 | 0 | 3253869 | 112723 | None | WS & UGD -Vol V - 2023-24 No. 27.1 ,P No-162 | Gate Valve:
Supply and delivery at site of brand new best make gate valve as per IS 778/1984 with ISI Mark and as per its latest amendments size 50mm
| Each | 1312.5 | 1312.5 | 1.0 | False | None | None | False | None | False | 1312.5 | 0 | 3253870 | 112723 | None | WS & UGD -Vol V - 2023-24 No. 13.43.1 P No-157 | Outdoor type Board: upto 6 HP
Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOLDirect Online Starter 2) S-D- Star Delta Starter
| Each | 9975.0 | 9975.0 | 1.0 | False | None | None | False | None | False | 9975.0 | 0 | 3253871 | 112723 | None | WS & UGD -Vol V - 2023-24 No. 13.25 ,P No-162 | Power capacitor
Supply and delivery at site best indigenous brand new power capacitor as per IS 2834/1986 with latest amendments with KPTCL authorities and erection, electrification and commissioning of the same at the location of respective pump sets.
| Kvar | 577.5 | 577.5 | 3.0 | False | None | None | False | None | False | 1732.5 | 0 | 3253872 | 112723 | None | WS & UGD -Vol V CSR-2023-24 I. No. 32 ,P No-162 | MCB
Supply and delivery at site delivery of best indigenous brand new MCB (Miniature Circuit Breakers) of required capacity as per IS 88228/1978 and its latest amendments and with ISI Mark of 6/10/16/20/25/40 Amps with scalable box.
| 3 Poles | 1207.5 | 1207.5 | 1.0 | False | None | None | False | None | False | 1207.5 | 0 | 3253873 | 112723 | None | WS & UGD -Vol V CSR -2023-24 No. 13.32 | HDPE Pipe:
Supplying, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc. Note: Upto 110mm dia Coil shall be used. For Grade PE80 PN6.0 : PE80 (PN 6.0 / 6 Kg/cm2) a. 63mm
| Mtr | 198.45 | 198.45 | 65.0 | False | None | None | False | None | False | 12899.25 | 0 | 3253874 | 112723 | None | WS & UGD Works Vol V CSR for the 2021-22 No. 13.32 | Errection,Electrification and commisioning works of Submersible Pump sets:
Labour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all items including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges,tools and equipments etc., involved in the job as per specifications, with necessary tests as per specifications, with testing of as per instructions of engineer incharge of work.
| Job | 6825.0 | 6825.0 | 1.0 | False | None | None | False | None | False | 6825.0 | 0 | 3253875 | 112723 | None | WS & UGD -Vol V CSR -2023-24 No. 13.33 | Pump sets:
Labour charges for erection of indoor type panel board and meter board units with all necessary materials and labour tools and equipments including cement concrete for foundation/bed etc,complete as per specification, with testing of as per instructions of engineer incharge of work.
| Job | 1417.5 | 1417.5 | 1.0 | False | None | None | False | None | False | 1417.5 | 0 | 3253876 | 112723 | None | WS & UGD -Vol V CSR -2023-24 No. 13.38.2 | Providing,Supplying and fixing suitable for 1.1 KV class UG cable filled with necessary bitumen insulating compound complete with terminals clamps,bolts,nuts and washers etc. with necessary materials and labour tools and equipments as per instructions of engineer incharge of work. Sqm
| Each | 472.5 | 472.5 | 1.0 | False | None | None | False | None | False | 472.5 | 0 | 3253877 | 112723 | None | WS & UGD -Vol V CSR -2023-24 No. 13.27.1 | Collar:
Supply and delivery of galvanized mild steel tubes of 6mtr standard length heavy duty (C Class) as per IS 1239 (Part-I) 1990 with latest amendments with ISI Mark (one end fitted with Heavy Duty collar and other end fitted with protective cover) a.50 mm
| Each | 3202.5 | 3202.5 | 1.0 | False | None | None | False | None | False | 3202.5 | 0 | 3253878 | 112723 | None | WS & UGD -Vol V CSR- 2023-24 No.13.39 | Earthing
Earthing: Supplying and fixing and wiring earth electrode for grounding circuits IC cutouts and other equipments on the meter board in the pit. The pits should be filled up with equal proportion of salt and charcoal 150mm around the pipe to complete depth. The connection from the pipe to the conduits etc. is to established through GI wire of sizes as per clause 7.3.3 of IS 732 using 12mm bolts, nuts, washers and check nuts, the pipe shall have 16 through holes of 12mm dia.
| Job | 3937.5 | 3937.5 | 1.0 | False | None | None | False | None | False | 3937.5 | 0 |
| 1717997961000 | 1 | None | None | Buildings | GROUND FLOOR SCHOOL | 7135031.15 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3253879 | 112724 | None | PWD DSR 2023-24 V -1 P.NO-08 I.NO-1.12 | Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work.In all kinds of soils upto 300 mm depth
| Cum | 99.75 | 99.75 | 240.0 | False | None | None | False | None | False | 23940.0 | 0 | 3253880 | 112724 | None | PWD DSR 2023-24 V -1 P.NO-08 I.NO-1.14.1 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work.In all kinds of soils Depth upto 3 m
| Cum | 107.1 | 107.1 | 376.88 | False | None | None | False | None | False | 40363.848 | 0 | 3253881 | 112724 | None | PWD DSR 2023-24 V -1 P.NO-15 I.NO-2.1.2 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates
| Cum | 5947.2 | 5947.2 | 63.21 | False | None | None | False | None | False | 375922.512 | 0 | 3253882 | 112724 | None | PWD DSR 2023-24 V -1 P.NO-15 I.NO-2.2.3 | Providing and laying in position Cement Concrete for all Foundation works. The granite /trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
| Cum | 6652.8 | 6652.8 | 26.78 | False | None | None | False | None | False | 178161.984 | 0 | 3253883 | 112724 | None | PWD CSR VOL I - 2023-24. I. No.2 P.No. 111 | Additionalities for Formwork, Centering & Scaffolding for Footing 8%
| Cum | 532.22 | 532.22 | 28.44 | False | None | None | False | None | False | 15136.3368 | 0 | 3253884 | 112724 | None | PWD DSR 2023-24 V -1 P.NO-15 I.NO-2.4.3 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The nite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, ding
all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
| Cum | 6652.8 | 6652.8 | 23.16 | False | None | None | False | None | False | 154078.848 | 0 | 3253885 | 112724 | None | PWD CSR VOL I - 2023-24. I. No.2 P.No. 111 | Additionalities for Formwork, Centering & Scaffolding for Plinth Beam 50%
| Cum | 3326.4 | 3326.4 | 23.17 | False | None | None | False | None | False | 77072.688 | 0 | 3253886 | 112724 | None | PWD CSR VOL I - 2023-24. I. No. 1.11 P.No. 7 | Filling approved earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m
| Cum | 454.65 | 454.65 | 416.67 | False | None | None | False | None | False | 189439.0155 | 0 | 3253887 | 112724 | None | PWD CSR VOL II - 2023-24. I. No. 4.1 P.No. 5 | Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated
earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications.
| Sqm | 123.9 | 123.9 | 142.1 | False | None | None | False | None | False | 17606.19 | 0 | 3253888 | 112724 | None | PWD CSR VOL I - 2023-24. I. No. 2.4.1P.No.16 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including
all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.Mix 1:2:4 (M15) Using 20 mm nominal size graded crushed coarse aggregates
| Sqm | 6724.2 | 6724.2 | 2.5 | False | None | None | False | None | False | 16810.5 | 0 | 3253889 | 112724 | None | PWD CSR VOL I - 2023-24. I. No. 2.5.2 P.No.16 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
| Cum | 7185.15 | 7185.15 | 1.01 | False | None | None | False | None | False | 7257.0015 | 0 | 3253890 | 112724 | None | PWD CSR VOL I - 2023-24. I. No.15 P.No. 112 | Additionalities for Formwork, Centering & Scaffolding for chejja 45%
| Cum | 3233.32 | 3233.32 | 1.35 | False | None | None | False | None | False | 4364.982 | 0 | 3253891 | 112724 | None | PWD DSR 2021-22 V - 1 I.No. 2.11 a | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.
| Tonne | 93929.85 | 93929.85 | 17.79 | False | None | None | False | None | False | 1671012.0315 | 0 | 3253892 | 112724 | None | PWD CSR VOL II - 2023-24. I. No. 5.2 P.No. 9 | Providing Coursed rubble masonry (first sort) with hard stone in foundation
and plinth with Cement mortar 1:6 (1 cement : 6 coarse sand
| Cum | 6948.9 | 6948.9 | 55.24 | False | None | None | False | None | False | 383857.236 | 0 | 3253893 | 112724 | None | PWD CSR VOL II - 2023-24. I. No. 5.3 P.No. 9 | Providing Coursed rubble masonry (second sort) with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand))
| Cum | 6515.25 | 6515.25 | 42.67 | False | None | None | False | None | False | 278005.7175 | 0 | 3253894 | 112724 | None | PWD CSR VOL II - 2023-24. I. No. 6.5 P.No.13 | Providing Brick work with common burnt clay machine moulded perforated bricks of class designation 5.0 conforming to IS: 2222 in superstructure above plinth level in cement mortar 1:6 (1 cement : 6 coarse sand) With Non modular bricks including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.
| Cum | 11525.85 | 11525.85 | 86.52 | False | None | None | False | None | False | 997216.542 | 0 | 3253895 | 112724 | None | PWD CSR VOL II - 2023-24. I. No.11.10.1 P.No.79 | Fixing standard steel glazed doors, windows and ventilators in walls, including fixing of float glass panes with glazing clips and special metalsash putty of approved make, or metal beading with screws, (only steel windows, glass panes cut to size and glazing clips or metal beading with screws, shall be supplied by department free of cost: Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.
| Kg | 46.2 | 46.2 | 1350.0 | False | None | None | False | None | False | 62370.0 | 0 | 3253896 | 112724 | None | PWD CSR VOL II - 2023-24. I. No.11.37.1 P.No.89 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in
basic item):With float glass panes of 4.0 mm thickness (weight not less than 10kg/ m²) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge
| Kg | 1037.4 | 1037.4 | 27.0 | False | None | None | False | None | False | 28009.8 | 0 | 3253897 | 112724 | None | PWD CSR VOL II - 2023-24. I. No.12.15 P.No.100 | Providing and fixing in position fully panelled Matti/ Nandi wood shutters for doors with, stiles and rails of 35mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. (excluding cost of fixtures ) the Engineer-in-Charge. | Sqm | 6904.8 | 6904.8 | 15.12 | False | None | None | False | None | False | 104400.576 | 0 | 3253898 | 112724 | None | PWD CSR VOL II - 2023-24. I. No.7.6 P.No.21 | Providing and fixing 15 cm wide, 45 cm overall semi-circular plain G.S. sheet gutter with iron brackets 40x3mm size, bolts, nuts and washers etc., including making necessary connections with rain water pipes complete. (0.63 mm thick with zinc coating not less than 275 g/m²)
| Rmtr | 677.25 | 677.25 | 14.0 | False | None | None | False | None | False | 9481.5 | 0 | 3253899 | 112724 | None | PWD CSR VOL II - 2023-24. I. No.7.25.1 P.No | Providing and fixing Green Board As Per Market Rate complete.
| Sqm | 666.75 | 666.75 | 6.0 | False | None | None | False | None | False | 4000.5 | 0 | 3253900 | 112724 | None | PWD CSR VOL II - 2023-24. I. No.6.13 P.No.14 | Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in foundations and plinth in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.
| Sqm | 1024.8 | 1024.8 | 86.91 | False | None | None | False | None | False | 89065.368 | 0 | 3253901 | 112724 | None | PWD CSR VOL II - 2023-24. I. No.8.8 P.No. | Providing and laying Vitrified tiles with thickness 9-10 mm in floor with different sizes with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately) Size of Tile 1000x1000 mm
| Sqm | 1418.55 | 1418.55 | 386.21 | False | None | None | False | None | False | 547858.1955 | 0 | 3253902 | 112724 | None | PWD CSR VOL II - 2023-24. I. No.8.8 P.No.42 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications
and as per directions of Engineer-in-charge
| Sqm | 389.55 | 389.55 | 225.14 | False | None | None | False | None | False | 87703.287 | 0 | 3253903 | 112724 | None | PWD CSR VOL II - 2023-24. I. No.8.25 P.No.45 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 143.85 | 143.85 | 319.44 | False | None | None | False | None | False | 45951.444 | 0 | 3253904 | 112724 | None | PWD CSR VOL II - 2023-24. I. No.8.28 P.No.45 | Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 93.45 | 93.45 | 253.58 | False | None | None | False | None | False | 23697.051 | 0 | 3253905 | 112724 | None | PWD CSR VOL II - 2023-24. I. No.8.45.1 P.No.49 | Varnishing with varnish of approved brand and manufacture :Two coats of glue sizing with copal varnish over an under coat of flatting varnish to give an even shade and produce a smooth dry and mat surface including preparing the surface after thorougly cleaning oil, grease, dirt and foreign mattersand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 180.6 | 180.6 | 54.72 | False | None | None | False | None | False | 9882.432 | 0 | 3253906 | 112724 | None | PWD CSR VOL II - 2023-24. I. No.8.45.1 P.No.49 | Varnishing with varnish of approved brand and manufacture :Two coats of glue sizing with copal varnish over an under coat of flatting varnish to give an even shade and produce a smooth dry and mat surface including preparing the surface after thorougly cleaning oil, grease, dirt and foreign mattersand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 180.6 | 180.6 | 25.2 | False | None | None | False | None | False | 4551.12 | 0 | 3253907 | 112724 | None | PWD CSR VOL II - 2023-24. I. No.11.28 P.No.85 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.
| Kg | 593.25 | 593.25 | 238.5 | False | None | None | False | None | False | 141490.125 | 0 | 3253908 | 112724 | None | PWD CSR VOL I - 2023-24. I. No. 2.5.2 P.No. 16 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical
specifications. .M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
| Cum | 7185.15 | 7185.15 | 108.2 | False | None | None | False | None | False | 777433.23 | 0 | 3253909 | 112724 | None | PWD CSR VOL I - 2023-24. I. No.9 P.No. 111 | Additionalities for Formwork, Centering & Scaffolding for Column 70%
| Cum | 5029.61 | 5029.61 | 10.6 | False | None | None | False | None | False | 53313.866 | 0 | 3253910 | 112724 | None | PWD CSR VOL I - 2023-24. I. No.14 P.No. 112 | Additionalities for Formwork, Centering & Scaffolding for Lintle&Roof Beam 60%
| Cum | 4311.09 | 4311.09 | 31.7 | False | None | None | False | None | False | 136661.553 | 0 | 3253911 | 112724 | None | PWD CSR VOL I - 2023-24. I. No.15 P.No. 112 | Additionalities for Formwork, Centering & Scaffolding for Roof Slab 50%
| Cum | 3592.58 | 3592.58 | 49.73 | False | None | None | False | None | False | 178659.0034 | 0 | 3253912 | 112724 | None | PWD CSR VOL I - 2023-24. I. No.16 P.No. 112 | Additionalities for Formwork, Centering & Scaffolding for Stair case 50%
| Cum | 3592.58 | 3592.58 | 5.9 | False | None | None | False | None | False | 21196.222 | 0 | 3253913 | 112724 | None | PWD CSR VOL II - 2023-24. I. No.8.6.1 P.No.42 | Providing 12 mm cement plaster with Cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer in-charge | Sqm | 339.15 | 339.15 | 400.97 | False | None | None | False | None | False | 135988.9755 | 0 | 3253914 | 112724 | None | PWD CSR VOL II - 2023-24. I. No.12.13.1 P.No.100 | Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. | Cum | 103755.75 | 103755.75 | 2.27 | False | None | None | False | None | False | 235525.5525 | 0 | 3253915 | 112724 | None | PWD CSR VOL II - 2023-24. I. No.8.16.1 P.No.43 | Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment
| Mtr | 35.7 | 35.7 | 211.37 | False | None | None | False | None | False | 7545.909 | 0 |
| 1717997961000 | 1 | None | None | Buildings | GROUND FLOOR TOILET | 1471133.36 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3253916 | 112725 | None | PWD DSR 2023-24 V -1 P.NO-08 I.NO-1.14.1 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work.In all kinds of soils Depth upto 3 m
| Cum | 107.1 | 107.1 | 32.4 | False | None | None | False | None | False | 3470.04 | 0 | 3253917 | 112725 | None | PWD DSR 2023-24 V -1 P.NO-06 I.NO-1.5.2 | Earth work excavation by manual means for drains,canals, waste weir draft,
approach channels, key trench, foundation of Bridges and such similar works,
as per drawing and technical specifications, including setting out, shoring,
strutting, barricading, caution lights, excavated surface leveled and sides neatly
dressed disposing off or leveling the excavated stuff or sorting & stacking the
selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost
of labour, tools, usage & other appurtenances required to complete the work.Depth exceeding 1.5m, but not exceeding 3 m
| Cum | 467.25 | 467.25 | 17.87 | False | None | None | False | None | False | 8349.7575 | 0 | 3253918 | 112725 | None | PWD DSR 2023-24 V -1 P.NO-7 I.NO-1.9 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of
foundations and other similar works etc. in layers not exceeding 20cm in depth,
consolidating each deposited layer by ramming and watering, lead up to 50 m
and lift upto 1.5 m
| Cum | 279.3 | 279.3 | 8.1 | False | None | None | False | None | False | 2262.33 | 0 | 3253919 | 112725 | None | PWD CSR VOL I 2023-24. I. No. 2.1.2 P.No. 15 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates
| Cum | 5947.2 | 5947.2 | 14.78 | False | None | None | False | None | False | 87899.616 | 0 | 3253920 | 112725 | None | PWD CSR VOL I 2023-24. I. No. 2.1.2 P.No. 15 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates
| Cum | 5947.2 | 5947.2 | 1.17 | False | None | None | False | None | False | 6958.224 | 0 | 3253921 | 112725 | None | PWD CSR VOL 2 2023-24. Sl. No. 5.2 , P.No. 09 | Providing Coursed rubble masonry (first sort) with hard stone in foundation
and plinth with Cement mortar 1:6 (1 cement : 6 coarse sand
| Cum | 6948.9 | 6948.9 | 6.62 | False | None | None | False | None | False | 46001.718 | 0 | 3253922 | 112725 | None | PWD CSR VOL 2 2023-24. Sl. No. 5.3 , P.No. 09 | Providing Coursed rubble masonry (second sort) with hard stone in
foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)
| Cum | 6515.25 | 6515.25 | 5.07 | False | None | None | False | None | False | 33032.3175 | 0 | 3253923 | 112725 | None | PWD CSR VOL I 2021-22. I. No. 1.8 P.No. 7 | Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work.
| Cum | 472.82 | 472.82 | 68.58 | False | None | None | False | None | False | 32425.9956 | 0 | 3253924 | 112725 | None | PWD SR- VOL I - 2023-24. I. No. 2.2.3 P.No. 15 | Providing and laying in position Cement Concrete for all Foundation works.
The granite/trap/basalt crushed graded coarse aggregates and fine aggregates
as per relevant IS Codes machine mixed with super plasticizers laid in finished
layers, well compacted using needle vibrators, including all lead & lifts, cost
of all materials, quality confirming to the requirements of relevant IS codes,
labour, Usage charges of machinery, curing and all the other appurtenances
required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates"
| Cum | 6652.8 | 6652.8 | 2.4 | False | None | None | False | None | False | 15966.72 | 0 | 3253925 | 112725 | None | PWD SR VOL I 2023-24. I. No. 3 P.No.111 | Appendix I Additionalities for Formwork, Centering & Scaffolding for Footing 5%
| Cum | 506.88 | 506.88 | 2.4 | False | None | None | False | None | False | 1216.512 | 0 | 3253926 | 112725 | None | PWD SR VOL I 2023-24. I. No. 2.2.3 P.No. 15 | Providing and laying in position Cement Concrete for all Foundation works.
The granite/trap/basalt crushed graded coarse aggregates and fine aggregates
as per relevant IS Codes machine mixed with super plasticizers laid in finished
layers, well compacted using needle vibrators, including all lead & lifts, cost
of all materials, quality confirming to the requirements of relevant IS codes,
labour, Usage charges of machinery, curing and all the other appurtenances
required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
| Cum | 6652.8 | 6652.8 | 0.63 | False | None | None | False | None | False | 4191.264 | 0 | 3253927 | 112725 | None | PWD SR VOL I 2023-24. I. No. 3 P.No.111 | Appendix I Additionalities for Formwork, Centering & Scaffolding for Column 70%
| Cum | 4656.96 | 4656.96 | 0.63 | False | None | None | False | None | False | 2933.8848 | 0 | 3253928 | 112725 | None | PWD SR VOL I 2023-24. I. No. 2.4.3 P.No. 16 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
| Cum | 6652.8 | 6652.8 | 4.3 | False | None | None | False | None | False | 28607.04 | 0 | 3253929 | 112725 | None | PWD SR VOL I 2023-24. I. No.3 P.No.111 | Appendix I Additionalities for Formwork, Centering & Scaffolding for Grade & Plinth Beam 50%
| Cum | 3326.4 | 3326.4 | 4.3 | False | None | None | False | None | False | 14303.52 | 0 | 3253930 | 112725 | None | PWD SR for Buildings VOL I for the year 2023-24. I | Providing and laying in position Cement Concrete for all Super structures of
building , Road works, Water works, Irrigation works & super structure works
of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse
aggregates and fine aggregates as per relevant IS Codes machine mixed with
super plasticisers laid in layers, well compacted using needle vibrators. The
cost includes all lead & lifts, cost of all materials, quality confirming to the
requirements of relevant IS codes , labour, Usage charges of machinery, curing
and all other appurtenances required to complete the work as per technical
specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
| Cum | 7185.15 | 7185.15 | 3.01 | False | None | None | False | None | False | 21627.3015 | 0 | 3253931 | 112725 | None | PWD SR VOL I 2023-24. I. No.3 P.No.111 | Appendix I Additionalities for Formwork, Centering & Scaffolding for Column 70%
| Cum | 5029.61 | 5029.61 | 3.01 | False | None | None | False | None | False | 15139.1261 | 0 | 3253932 | 112725 | None | PWD SR VOL I 2023-24. I. No. 2.5.2 P.No. 16 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
| Cum | 7185.15 | 7185.15 | 1.98 | False | None | None | False | None | False | 14226.597 | 0 | 3253933 | 112725 | None | PWD SR VOL I 2023-24. I. No.14 P.No.112 | Appendix I Additionalities for Formwork, Centering & Scaffolding for Lintel Beam 60%
| Cum | 4311.09 | 4311.09 | 1.98 | False | None | None | False | None | False | 8535.9582 | 0 | 3253934 | 112725 | None | PWD SR VOL I 2023-24. I. No. 2.5.2 P.No. 16 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
| Cum | 7185.15 | 7185.15 | 2.36 | False | None | None | False | None | False | 16956.954 | 0 | 3253935 | 112725 | None | PWD SR VOL I 2023-24. I. No.14 P.No.112 | Appendix I Additionalities for Formwork, Centering & Scaffolding for Roof Beam 20%
| Cum | 4311.09 | 4311.09 | 2.36 | False | None | None | False | None | False | 10174.1724 | 0 | 3253936 | 112725 | None | PWD SR VOL I 2023-24. I. No. 2.5.2 P.No. 16 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
| Cum | 7185.15 | 7185.15 | 7.69 | False | None | None | False | None | False | 55253.8035 | 0 | 3253937 | 112725 | None | PWD SR for Buildings VOL I for the year 2023-24. I | Appendix I Additionalities for Formwork, Centering & Scaffolding for Roof Slab 50%
| Cum | 3592.58 | 3592.58 | 7.69 | False | None | None | False | None | False | 27626.9402 | 0 | 3253938 | 112725 | None | PWD SR VOL II 2023-24. I. No.6.13 P.No. 14 | Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in foundations and plinth in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.
| Cum | 1024.8 | 1024.8 | 13.23 | False | None | None | False | None | False | 13558.104 | 0 | 3253939 | 112725 | None | PWD SR VOL II 2023-24. I. No.6.13 P.No. 14 | Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:4 (1 cement :4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.
| Sqm | 1024.8 | 1024.8 | 119.66 | False | None | None | False | None | False | 122627.568 | 0 | 3253940 | 112725 | None | PWD SR VOL II 2023-24. I. No.6.16 P.No. 15 | Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry.
| Sqm | 99.75 | 99.75 | 119.66 | False | None | None | False | None | False | 11936.085 | 0 | 3253941 | 112725 | None | PWD SR VOL II 2023-24. I. No.8.6.1 P.No. 42 | Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 339.15 | 339.15 | 196.77 | False | None | None | False | None | False | 66734.5455 | 0 | 3253942 | 112725 | None | PWD SR VOL II 2023-24. I. No.8.9 P.No. 42 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 404.25 | 404.25 | 107.68 | False | None | None | False | None | False | 43529.64 | 0 | 3253943 | 112725 | None | PWD SR VOL II 2023-24. I. No.8.7 P.No. 42 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 384.3 | 384.3 | 138.56 | False | None | None | False | None | False | 53248.608 | 0 | 3253944 | 112725 | None | PWD SR VOL II 2023-24. I. No.8.51 P.No. 50 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.
| Sqm | 105.0 | 105.0 | 244.7 | False | None | None | False | None | False | 25693.5 | 0 | 3253945 | 112725 | None | PWD SR VOL II 2023-24. I. No.12.13.1 P.No. 100 | Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications.
| Cum | 103755.75 | 103755.75 | 0.15 | False | None | None | False | None | False | 15563.3625 | 0 | 3253946 | 112725 | None | PWD SR VOL II 2023-24. I. No.12.54.1 P.No. 104 | Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge.
| Sqm | 333.9 | 333.9 | 91.2 | False | None | None | False | None | False | 30451.68 | 0 | 3253947 | 112725 | None | PWD SR VOL II 2023-24. I. No.12.57.6 P.No. 105 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per specification. 35 mm thick both side commercial
| Sqm | 3488.1 | 3488.1 | 3.49 | False | None | None | False | None | False | 12173.469 | 0 | 3253948 | 112725 | None | PWD SR VOL II 2023-24. I. No.12.55.1 P.No. 104 | Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges. with one side prelam
| Nos | 2484.3 | 2484.3 | 25.2 | False | None | None | False | None | False | 62604.36 | 0 | 3253949 | 112725 | None | PWD SR VOL II 2023-24. I. No.12.51 P.No. 104 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications.
| Nos | 1066.8 | 1066.8 | 2.0 | False | None | None | False | None | False | 2133.6 | 0 | 3253950 | 112725 | None | PWD SR VOL II 2023-24. I. No.12.85 P.No. 109 | Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made | Sqm | 6004.95 | 6004.95 | 6.84 | False | None | None | False | None | False | 41073.858 | 0 | 3253951 | 112725 | None | PWD SR VOL II 2023-24. I. No.12.34A P.No. 86 | Providing and fixing M.S. grills of required pattern in frames of windows
etc. with M.S. flats, square or round bars etc. including priming coat with
approved steel primer all complete. Fixed to steel windows by welding
| Kgs | 176.4 | 176.4 | 143.64 | False | None | None | False | None | False | 25338.096 | 0 | 3253952 | 112725 | None | PWD SR VOL II 2023-24. I. No.9.11A P.No.60 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete.
| Sqm | 933.45 | 933.45 | 47.93 | False | None | None | False | None | False | 44740.2585 | 0 | 3253953 | 112725 | None | PWD SR VOL II 2023-24. I. No. 9.39 P.No. 65 | Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications.
| Sqm | 1521.45 | 1521.45 | 136.08 | False | None | None | False | None | False | 207038.916 | 0 | 3253954 | 112725 | None | PWD SR VOL II 2023-24. I. No. 8.33.3 P.No. 47 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @ 0.80 ltr/10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 145.95 | 145.95 | 6.84 | False | None | None | False | None | False | 998.298 | 0 | 3253955 | 112725 | None | PWD SR VOL II 2023-24. I. No. 8.33.1 P.No. 46 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Special primer applied @ 0.75 ltr /10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 165.9 | 165.9 | 196.77 | False | None | None | False | None | False | 32644.143 | 0 | 3253956 | 112725 | None | PWD SR VOL II 2023-24. I. No. 8.33.1 P.No. 46 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Special primer applied @ 0.75 ltr /10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 165.9 | 165.9 | 47.93 | False | None | None | False | None | False | 7951.587 | 0 | 3253957 | 112725 | None | PWD SR VOL II 2023-24. I. No. 8.30 P.No. 46 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including riming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 182.7 | 182.7 | 107.68 | False | None | None | False | None | False | 19673.136 | 0 | 3253958 | 112725 | None | PWD CSR VOL II 2023-24. I. No. 8.19.1 P.No. 44 | Providing Flush/ Ruled pointing: Pointing on stone work with cement mortar 1:3 (1 cement : 3 fine sand) after raking joints to depth nicely lining, including cost of materials, labour, curing as per specifications and as per directions of Engineer-in-charge.
| Sqm | 267.75 | 267.75 | 20.4 | False | None | None | False | None | False | 5462.1 | 0 | 3253959 | 112725 | None | PWD SR VOL I 2023-24, I. No. 2.11a P.No.18 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. | Tonne | 93929.85 | 93929.85 | 1.73 | False | None | None | False | None | False | 162498.6405 | 0 | 3253960 | 112725 | None | PWD CSR VOL II 2023-24. I. No. 8.49 P.No. 49 | Lettering with black Japan paint of approved brand and manufacture to give an even shade including preparing the surface after thoroughly cleaning the surface to remove all dirt, dust and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
| cm | 4.2 | 4.2 | 1500.0 | False | None | None | False | None | False | 6300.0 | 0 |
| 1717997961000 | 1 | None | None | Buildings | ELECTRICAL FOR TOILET | 93145.5 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3253961 | 112726 | None | PWD Ele. SR 2023-24, P. No-02, It No- 1.2.1 | Supplying heavy gauge PVC conduit pipe 19/20mm dia 2mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary
| Mtr | 69.3 | 69.3 | 120.0 | False | None | None | False | None | False | 8316.0 | 0 | 3253962 | 112726 | None | PWD Ele. SR 2023-24, P. No-01, It No- 1.2.2 | 25mm dia 2mm thick
| Mtr | 81.9 | 81.9 | 90.0 | False | None | None | False | None | False | 7371.0 | 0 | 3253963 | 112726 | None | PWD Ele. SR 2023-24, P.No-01,It No- 1.3.1 | Supplying heavy gauge PVC Conduit Pipe 19/20mm dia 2mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary.
| Mtr | 71.4 | 71.4 | 40.0 | False | None | None | False | None | False | 2856.0 | 0 | 3253964 | 112726 | None | PWD Ele.SR 2023-24, P.No-01, It No- 1.3.2 | 25mm dia 2mm thick
| Mtr | 84.0 | 84.0 | 80.0 | False | None | None | False | None | False | 6720.0 | 0 | 3253965 | 112726 | None | PWD Ele. SR 2022-23, P.No-03, It No- 2.2.1 | Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2X1.5Sq.mm Cable confirming to the GTP without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet. Short point upto 3Mtr from tapping point to out let via switch box
| Point | 263.55 | 263.55 | 12.0 | False | None | None | False | None | False | 3162.6 | 0 | 3253966 | 112726 | None | PWD Ele. SR 2022-23, P.No-03, It No- 2.2.2 | Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch box
| Point | 379.05 | 379.05 | 20.0 | False | None | None | False | None | False | 7581.0 | 0 | 3253967 | 112726 | None | PWD Ele. SR 2022-23, P. No-03, It No- 2.2.3 | Long point above 6Mtr upto 10Mtr from tapping point to out let via switch box
| Point | 569.1 | 569.1 | 20.0 | False | None | None | False | None | False | 11382.0 | 0 | 3253968 | 112726 | None | PWD Ele. SR 2022-23, P.No-03, It No- 2.3.2 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 1.5sqmm.
| Mtr | 27.3 | 27.3 | 250.0 | False | None | None | False | None | False | 6825.0 | 0 | 3253969 | 112726 | None | PWD Ele. SR 2022-23, P.No-03, It No- 2.3.3 | 2.5sqmm.
| Mtr | 42.0 | 42.0 | 250.0 | False | None | None | False | None | False | 10500.0 | 0 | 3253970 | 112726 | None | PWD Ele. SR 2022-23, P.No-03, It No- 2.3.4 | 4.0sqmm.
| Mtr | 61.95 | 61.95 | 100.0 | False | None | None | False | None | False | 6195.0 | 0 | 3253971 | 112726 | None | PWD Ele. SR 2022-23, P.No-6, It No- 3.14.6 | 6Amps lamp holder
| No | 66.15 | 66.15 | 12.0 | False | None | None | False | None | False | 793.8 | 0 | 3253972 | 112726 | None | PWD Ele. SR 2022-23, P.No-5, It No- 3.1.1 | Supplying 6A flush type socket and 6 amps flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3654 - 6Amps 2 Way
| Each | 127.05 | 127.05 | 10.0 | False | None | None | False | None | False | 1270.5 | 0 | 3253973 | 112726 | None | PWD Ele. SR 2022-23, P.No-5, It No- 3.6.1 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 6Amps one way switch.
| Each | 92.4 | 92.4 | 10.0 | False | None | None | False | None | False | 924.0 | 0 | 3253974 | 112726 | None | PWD Ele. SR 2022-23, P.No-5, It No- 3.6.8 | 16Amps one way switch.
| Each | 261.45 | 261.45 | 10.0 | False | None | None | False | None | False | 2614.5 | 0 | 3253975 | 112726 | None | PWD Ele. SR 2022-23, P. No-5, It No- 3.6.11 | 6/16Amps universal socket.
| Each | 261.45 | 261.45 | 1.0 | False | None | None | False | None | False | 261.45 | 0 | 3253976 | 112726 | None | PWD Ele. SR 2022-23, P.No-5, It No- 3.4.2 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall . 4-5Way
| Each | 144.9 | 144.9 | 4.0 | False | None | None | False | None | False | 579.6 | 0 | 3253977 | 112726 | None | PWD Ele. SR 2022-23, P. No-5, It No- 3.4.4 | 8Way
| Each | 262.5 | 262.5 | 1.0 | False | None | None | False | None | False | 262.5 | 0 | 3253978 | 112726 | None | PWD Ele. SR 2022-23, P. No-5, It No- 3.4.5 | 10-12Way
| Each | 341.25 | 341.25 | 1.0 | False | None | None | False | None | False | 341.25 | 0 | 3253979 | 112726 | None | PWD Ele. SR 2022-23, P. No-5, It No- 3.5.2 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. - 4 Module
| Each | 183.75 | 183.75 | 4.0 | False | None | None | False | None | False | 735.0 | 0 | 3253980 | 112726 | None | PWD Ele. SR 2022-23, P.No-5, It No- 3.5.4 | 8Module
| Each | 317.1 | 317.1 | 2.0 | False | None | None | False | None | False | 634.2 | 0 | 3253981 | 112726 | None | PWD Ele. SR 2022-23, P. No-5, It No- 3.5.5 | 10-12Module
| Each | 381.15 | 381.15 | 2.0 | False | None | None | False | None | False | 762.3 | 0 | 3253982 | 112726 | None | PWD Ele. SR 2022-23, P. No-38 , It No- 11.13.2 | Supplying and fixing of slim patty fitting, made out of CRCA
Sheet metal body with locking type holder completely wired. Excluding Ballast & Fluorescent Tube. 1 x 4' Tube light fitting.
| Each | 255.15 | 255.15 | 8.0 | False | None | None | False | None | False | 2041.2 | 0 | 3253983 | 112726 | None | PWD Ele. SR 2022-23, P. No-39 , It No- 12.12.1 | Supplying and fixing/replacing of fluorescent tube. 18 to 40W
| Each | 96.6 | 96.6 | 8.0 | False | None | None | False | None | False | 772.8 | 0 | 3253984 | 112726 | None | PWD Ele.SR 2022-23, P. No-13, It No- 5.17.1 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32Amps SP
| Each | 549.15 | 549.15 | 6.0 | False | None | None | False | None | False | 3294.9 | 0 | 3253985 | 112726 | None | PWD Ele.SR 2022-23, P. No-13, It No- 5.17.4 | 6-32 Amps DP
| Each | 1158.15 | 1158.15 | 6.0 | False | None | None | False | None | False | 6948.9 | 0 |
| 1717997961000 | 1 | None | None | Buildings | FIRST FLOOR SCHOOL BUILDING | 1741770.16 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3253986 | 112727 | None | PWD CSR VOL I - 2023-24. I. No.2.5.2 P.No.16 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 7185.15 | 7185.15 | 36.23 | False | None | None | False | None | False | 260317.9845 | 0 | 3253987 | 112727 | None | PWD CSR VOL I - 2023-24. I. No. 9 P.No. 111 | Additionalities for Formwork, Centering & Scaffolding for Column 70%
| Cum | 5029.61 | 5029.61 | 4.55 | False | None | None | False | None | False | 22884.7255 | 0 | 3253988 | 112727 | None | PWD CSR VOL I - 2023-24. I. No. 14 P.No. 112 | Additionalities for Formwork, Centering & Scaffolding for Lintel&Roof beam 60% | Cum | 4311.09 | 4311.09 | 11.53 | False | None | None | False | None | False | 49706.8677 | 0 | 3253989 | 112727 | None | PWD CSR VOL I - 2023-24. I. No. 15 P.No. 112 | Additionalities for Formwork, Centering & Scaffolding for Slab 50% | Cum | 3592.58 | 3592.58 | 17.0 | False | None | None | False | None | False | 61073.86 | 0 | 3253990 | 112727 | None | PWD CSR VOL I - 2023-24. I. No. 16 P.No. 112 | Additionalities for Formwork, Centering & Scaffolding for Stair case 50% | Cum | 3592.58 | 3592.58 | 3.14 | False | None | None | False | None | False | 11280.7012 | 0 | 3253991 | 112727 | None | PWD CSR VOL I - 2023-24. I. No. 2.4.1 P.No. 16 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, cluding all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.Mix 1:2:4 (M15) Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6724.2 | 6724.2 | 1.07 | False | None | None | False | None | False | 7194.894 | 0 | 3253992 | 112727 | None | PWD CSR VOL I - 2023-24. I. No. 2.5.2 P.No.16 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregateS | Cum | 7185.15 | 7185.15 | 0.56 | False | None | None | False | None | False | 4023.684 | 0 | 3253993 | 112727 | None | PWD SR 2023-24 V-1 Page No .112 SI No 19 | Addendum I Percentage Additionalities for Formwork, Centering & Scaffoldin Above the Item for Chejja45% | Cum | 3233.32 | 3233.32 | 0.56 | False | None | None | False | None | False | 1810.6592 | 0 | 3253994 | 112727 | None | PWD SR VOL I 2023-24, I. No. 2.11a P.No.18 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. | Tonne | 93929.85 | 93929.85 | 2.31 | False | None | None | False | None | False | 216977.9535 | 0 | 3253995 | 112727 | None | PWD CSR VOL II - 2023-24. I. No.6.5 P.No.13 | Providing Brick work with common burnt clay machine moulded perforated bricks of class designation 5.0 conforming to IS: 2222 in superstructure above plinth level in cement mortar 1:6 (1 cement : 6 coarse sand) With Non modular bricks including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. | Cum | 11525.85 | 11525.85 | 38.21 | False | None | None | False | None | False | 440402.7285 | 0 | 3253996 | 112727 | None | PWD CSR VOL II - 2023-24. I. No.11.10.1 P.No.79 | Fixing standard steel glazed doors, windows and ventilators in walls, including fixing of float glass panes with glazing clips and special metalsash putty of approved make, or metal beading with screws, (only steel windows, glass panes cut to size and glazing clips or metal beading with screws, shall be supplied by department free of cost: Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Kg | 46.2 | 46.2 | 464.4 | False | None | None | False | None | False | 21455.28 | 0 | 3253997 | 112727 | None | PWD CSR VOL II - 2023-24. I. No.11.37.1 P.No.89 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness (weight not less than 10kg/ m²) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge | Sqm | 1037.4 | 1037.4 | 15.48 | False | None | None | False | None | False | 16058.952 | 0 | 3253998 | 112727 | None | PWD CSR VOL II - 2023-24. I. No.12.13.1 P.No.100 | Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. | Cum | 103755.75 | 103755.75 | 0.32 | False | None | None | False | None | False | 33201.84 | 0 | 3253999 | 112727 | None | PWD CSR VOL II - 2023-24. I. No.12.15 P.No.100 | Providing and fixing in position fully panelled Matti/Nandi wood shutters for doors with, stiles and rails of 35mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. (excluding cost of fixtures ) | Sqm | 6904.8 | 6904.8 | 5.04 | False | None | None | False | None | False | 34800.192 | 0 | 3254000 | 112727 | None | PWD CSR VOL II - 2023-24. I. No.7.6 P.No.21 | Providing and fixing 15 cm wide, 45 cm overall semi-circular plain G.S.sheet gutter with iron brackets 40x3mm size, bolts, nuts and washers etc., including making necessary connections with rain water pipes complete. (0.63 mm thick with zinc coating not less than 275 g/m²) | Rmtr | 677.25 | 677.25 | 21.0 | False | None | None | False | None | False | 14222.25 | 0 | 3254001 | 112727 | None | PWD CSR VOL II - 2023-24. I. No.7.25.1 | PProviding and fixing plain multipurpose cement board(Hight pressure steam cured) with suitable screws for cement particle board in ceiling etc. complete 6 mm thick Cement fiber board as per IS: 14862
| Sqm | 666.75 | 666.75 | 10.0 | False | None | None | False | None | False | 6667.5 | 0 | 3254002 | 112727 | None | PWD CSR VOL II - 2023-24. I. No.6.13 P.No.14 | Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in foundations and plinth in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work | Sqm | 1024.8 | 1024.8 | 37.58 | False | None | None | False | None | False | 38511.984 | 0 | 3254003 | 112727 | None | PWD CSR VOL II - 2023-24. I. No.9.21.3 P.No.14 | Providing and laying Vitrified tiles with thickness 9-10 mm in floor with different sizes with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately) Size of Tile 1000x1000 mm | Sqm | 1418.55 | 1418.55 | 130.08 | False | None | None | False | None | False | 184524.984 | 0 | 3254004 | 112727 | None | PWD CSR VOL II - 2023-24. I. No.8.9 P.No.42 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 404.25 | 404.25 | 202.52 | False | None | None | False | None | False | 81868.71 | 0 | 3254005 | 112727 | None | PWD CSR VOL II - 2023-24. I. No.8.6.1 P.No.42 | Providing 12 mm cement plaster with Cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer in-charge. | Sqm | 339.15 | 339.15 | 98.66 | False | None | None | False | None | False | 33460.539 | 0 | 3254006 | 112727 | None | PWD CSR VOL II - 2023-24. I. No.8.25 P.No.45 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 143.85 | 143.85 | 98.66 | False | None | None | False | None | False | 14192.241 | 0 | 3254007 | 112727 | None | PWD CSR VOL II - 2023-24. I. No.8.28 P.No.45 | Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 93.45 | 93.45 | 155.62 | False | None | None | False | None | False | 14542.689 | 0 | 3254008 | 112727 | None | PWD CSR VOL II - 2023-24. I. No.8.45.1 P.No.49 | Varnishing with varnish of approved brand and manufacture :Two coats of glue sizing with copal varnish over an under coat of flatting varnish to give an even shade and produce a smooth dry and mat surface including preparing the surface after thorougly cleaning oil, grease, dirt and foreign mattersand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 180.6 | 180.6 | 15.48 | False | None | None | False | None | False | 2795.688 | 0 | 3254009 | 112727 | None | PWD CSR VOL II - 2023-24. I. No.8.45.1 P.No.49 | Varnishing with varnish of approved brand and manufacture :Two coats of glue sizing with copal varnish over an under coat of flatting varnish to give an even shade and produce a smooth dry and mat surface including preparing the surface after thorougly cleaning oil, grease, dirt and foreign mattersand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 180.6 | 180.6 | 5.04 | False | None | None | False | None | False | 910.224 | 0 | 3254010 | 112727 | None | PWD CSR VOL II - 2023-24. I. No.11.28 P.No.85 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Kg | 593.25 | 593.25 | 207.0 | False | None | None | False | None | False | 122802.75 | 0 | 3254011 | 112727 | None | PWD Ele- SR 2023-24, P. No-01, It No- 1.2.1 | Electrical Item
Concealed Conduit System :Supplying heavy gauge PVC conduit pipe . mm dia.mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary - 25mm dia 2mm thick. | Mtr | 69.3 | 69.3 | 25.0 | False | None | None | False | None | False | 1732.5 | 0 | 3254012 | 112727 | None | PWD Ele-SR 2023-24, P. No-01, It No- 1.3.1 | Supplying heavy gauge PVC Conduit Pipe 19/20mm dia 2mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. | Mtr | 71.4 | 71.4 | 40.0 | False | None | None | False | None | False | 2856.0 | 0 | 3254013 | 112727 | None | PWD Ele- SR 2023-24, P. No-03, It No- 2.2.1 | Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2X1.5Sq.mm Cable confirming to the GTP without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet. Short point upto 3Mtr from tapping point to out let via switch box | Point | 263.55 | 263.55 | 12.0 | False | None | None | False | None | False | 3162.6 | 0 | 3254014 | 112727 | None | PWD Ele-SR 2023-24, P.No-22, It No- 6.3.2 | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system. - 48" Sweep (1200mm) Regular model | Each | 3182.55 | 3182.55 | 4.0 | False | None | None | False | None | False | 12730.2 | 0 | 3254015 | 112727 | None | PWD Ele-SR 2023-24, P.No-22, It No- 2.1.5 | Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. - SThree outlet in a row, above 6Mts upto 10Mtr from tapping point to out let via switches | Point | 1086.75 | 1086.75 | 20.0 | False | None | None | False | None | False | 21735.0 | 0 | 3254016 | 112727 | None | PWD Ele-SR 2023-24, P.No-22, It No- 1.4.4 | Supplying and fixing sheet metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc. - 180x90x65mm | Each | 169.05 | 169.05 | 10.0 | False | None | None | False | None | False | 1690.5 | 0 | 3254017 | 112727 | None | PWD Ele-SR 2023-24, P.No-3, It No- 1.6.1 | Supplying and flush mounting teak wooden box without front plank, made of not less than 12mm thick wood, after due groove cutting, finishing with necessary cement plastering complete. - 12"x12"x3" (300x300x76mm)
| Each | 126.0 | 126.0 | 8.0 | False | None | None | False | None | False | 1008.0 | 0 | 3254018 | 112727 | None | PWD Ele-SR 2023-24, P.No-22, It No- 11.13.1 | Supplying and fixing of slim patty fitting, made out of CRCA Sheet metal body with locking type holder completely wired. Excluding Ballast & Fluorescent Tube. 769 1 x 4' Tube light fitting. | Each | 194.25 | 194.25 | 6.0 | False | None | None | False | None | False | 1165.5 | 0 |
| 1717997961000 | 1 | None | None | Buildings | GROUND FLOOR SCHOOL ELECTRICAL | 393321.93 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3254019 | 112728 | None | UNI CSR 2023-24 PWD Vol-6 Elec Uti Part-III It No | Supplying heavy gauge PVC conduit pipe 19/20mm dia 2mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc., and fixing using inverted wood plugs in case of RCC ceiling and RCC wall / stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws.
| Mtr | 69.3 | 69.3 | 500.0 | False | None | None | False | None | False | 34650.0 | 0 | 3254020 | 112728 | None | UNI CSR 2023-24 PWDV ol-6 Elec Uti Part-III It No | 25mm dia 2mm thick
| Mtr | 81.9 | 81.9 | 50.0 | False | None | None | False | None | False | 4095.0 | 0 | 3254021 | 112728 | None | UNI CSR 2023-24 PWD Vol-6 Elec UtiPart-IIIIt No | Supplying heavy gauge PVC Conduit Pipe 19/20mm dia 2mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary.
| Mtr | 71.4 | 71.4 | 100.0 | False | None | None | False | None | False | 7140.0 | 0 | 3254022 | 112728 | None | UNI CSR 2023-24 PWD Vol-6 Elec Uti Part-III It No | Supplying heavy gauge PVC Conduit Pipe 25mm dia 2mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary.
| Mtr | 82.95 | 82.95 | 20.0 | False | None | None | False | None | False | 1659.0 | 0 | 3254023 | 112728 | None | UNI CSR 2023-24 PWD Vol-6 Elec Uti Part-III It No | Supplying And Fixing Metal Fan Box with Round Hook.
| Each | 122.85 | 122.85 | 26.0 | False | None | None | False | None | False | 3194.1 | 0 | 3254024 | 112728 | None | UNI CSR 2023-24 PWD Vol-6 Elec UtiPart-IIIIt No | Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2X1.5Sq.mm Cable confirming to the GTP without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet. GROUP A - Short point upto 3Mtr from tapping point to out let via switch box
| Point | 282.45 | 282.45 | 26.0 | False | None | None | False | None | False | 7343.7 | 0 | 3254025 | 112728 | None | UNI CSR 2023-24 PWD Vol-6 Elec UtiPart-IIIIt No | Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch box
| Point | 397.95 | 397.95 | 31.0 | False | None | None | False | None | False | 12336.45 | 0 | 3254026 | 112728 | None | UNI CSR 2023-24 PWD Vol-6 Elec UtiPart-IIIIt No | Long point above 6Mtr upto 10Mtr from tapping point to out let via switch box
| Point | 582.75 | 582.75 | 6.0 | False | None | None | False | None | False | 3496.5 | 0 | 3254027 | 112728 | None | UNI CSR 2023-24 PWD Vol-6 Elec Uti Part-IIIIt N | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 - 1.5sqmm.
| Mtr | 27.3 | 27.3 | 1000.0 | False | None | None | False | None | False | 27300.0 | 0 | 3254028 | 112728 | None | UNI CSR 2023-24 PWD Vol-6 Elec Uti Part-IIIIt No | 2.5sqmm.
| Mtr | 44.1 | 44.1 | 1000.0 | False | None | None | False | None | False | 44100.0 | 0 | 3254029 | 112728 | None | UNI CSR 2023-24 PWD Vol-6 Elec Uti Part-III It No | 4.0sqmm.
| Mtr | 66.15 | 66.15 | 75.0 | False | None | None | False | None | False | 4961.25 | 0 | 3254030 | 112728 | None | UNI CSR 2023-24 PWDVol-6 Elec Uti Part-III It No | Supplying 6A flush type socket and 6 amps flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3654 - 6Amps 2 Way
| Each | 134.4 | 134.4 | 4.0 | False | None | None | False | None | False | 537.6 | 0 | 3254031 | 112728 | None | UNI CSR 2023-24PWD Vol-6 Elec Uti Part-III It No | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 4-5 Way
| Each | 143.85 | 143.85 | 10.0 | False | None | None | False | None | False | 1438.5 | 0 | 3254032 | 112728 | None | UNI CSR 2023-24 PWD Vol-6 Elec Uti Part-III It No | 8 - Way
| Each | 229.95 | 229.95 | 8.0 | False | None | None | False | None | False | 1839.6 | 0 | 3254033 | 112728 | None | UNI CSR 2023-24 PWD Vol-6 Elec Uti Part-III It No | 10-12 Way
| Each | 274.05 | 274.05 | 10.0 | False | None | None | False | None | False | 2740.5 | 0 | 3254034 | 112728 | None | UNI CSR 2023-24 PWD Vol-6 Elec Uti Part-IIIIt No | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. - 4-5 Module
| Each | 183.75 | 183.75 | 10.0 | False | None | None | False | None | False | 1837.5 | 0 | 3254035 | 112728 | None | UNI CSR 2023-24 PWD Vol-6 Elec Uti -III It No | 8 - Module
| Each | 298.2 | 298.2 | 8.0 | False | None | None | False | None | False | 2385.6 | 0 | 3254036 | 112728 | None | UNI CSR 2023-24 PWD Vol-6 Elec Uti Part-III It No | 10-12 Module
| Each | 361.2 | 361.2 | 10.0 | False | None | None | False | None | False | 3612.0 | 0 | 3254037 | 112728 | None | UNI CSR 2023-24 PWD Vol-6 Elec Uti Part-III It No | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 6Amps One way switch.
| Each | 107.1 | 107.1 | 80.0 | False | None | None | False | None | False | 8568.0 | 0 | 3254038 | 112728 | None | UNI CSR 2023-24 PWD Vol-6 Elec Uti Part-III It No | Stepped Fan Regulator Two Module
| Each | 374.85 | 374.85 | 26.0 | False | None | None | False | None | False | 9746.1 | 0 | 3254039 | 112728 | None | UNI CSR 2023-24 PWD Vol-6 Elec Uti Part-III It No | 16 A One Way Switch
| Each | 189.0 | 189.0 | 4.0 | False | None | None | False | None | False | 756.0 | 0 | 3254040 | 112728 | None | UNI CSR 2023-24 PWD Vol-6 Ele Uti Part-III It No | 6 16 A Universal Socket
| Each | 247.8 | 247.8 | 16.0 | False | None | None | False | None | False | 3964.8 | 0 | 3254041 | 112728 | None | UNI CSR2023-24 PWD-6 Elec Uti Part-III It No | TV / Telephone Socket
| Each | 163.8 | 163.8 | 2.0 | False | None | None | False | None | False | 327.6 | 0 | 3254042 | 112728 | None | UNI CSR 2023-24 PWD Vol-6 Elec Uti Part-III It No | RJ 45/I.O Outlet Cat-6
| Each | 353.85 | 353.85 | 12.0 | False | None | None | False | None | False | 4246.2 | 0 | 3254043 | 112728 | None | UNI CSR 2023-24 PWD Vol-6 Elec Uti Part-III It No | Supplying of Switch disconnector fuse unit (TPN) HRC type (but without HRC fuses). With AC-23A duty and as per IS-13947. - 63Amps
| Each | 2427.6 | 2427.6 | 1.0 | False | None | None | False | None | False | 2427.6 | 0 | 3254044 | 112728 | None | UNI CSR 2023-24 PWD Vol-6 Elec Uti Part-III It No | Supplying and fixing regular MCCB distribution Panel confirming to IS 8828, on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing of suitable type capacity MCCB's as an incomer for 3 phase Double door with necessary bus bar completely wired to use on 440Volts 3phase 4 wire powder coated painting etc., complete with a provision for fixing of single/three phase suitable capacity MCCB/MCB's as outgoings confirming to IS8828. - 12-Way
| Each | 16305.45 | 16305.45 | 1.0 | False | None | None | False | None | False | 16305.45 | 0 | 3254045 | 112728 | None | UNI CSR 2023-24 PWD Vol-6 Elec Uti Part-III It No | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. - 6-32Amps SP
| Each | 435.75 | 435.75 | 4.0 | False | None | None | False | None | False | 1743.0 | 0 | 3254046 | 112728 | None | UNI CSR 2023-24 PWD Vol-6 Elec Uti Part-III It No | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. - 5-32 Amps DP
| Each | 775.95 | 775.95 | 2.0 | False | None | None | False | None | False | 1551.9 | 0 | 3254047 | 112728 | None | UNI CSR 2023-24 PWD Vol-6 Elec Uti Part-III It No | Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG MS enclosure.I - Single Door -12 Way SP &N
| Each | 1956.15 | 1956.15 | 1.0 | False | None | None | False | None | False | 1956.15 | 0 | 3254048 | 112728 | None | UNI CSR 2023-24nPWD Vol-6 Elec Uti Part-III It No | Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker [ELMCB] 240/450V up to 300mA sensitivity on existing wood/panel board. - 63 Amps 4 pole
| Each | 3210.9 | 3210.9 | 1.0 | False | None | None | False | None | False | 3210.9 | 0 | 3254049 | 112728 | None | UNI CSR 2023-24 PWD Vol-6 Elec Uti Part-III It No | Fabricating supplying and mounting MS box made out … SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete. - 14SWG
| Each | 0.53 | 0.53 | 4000.0 | False | None | None | False | None | False | 2120.0 | 0 | 3254050 | 112728 | None | UNI CSR 2023-24 PWD Vol-6 Elec Uti Part-III It No | Supply and Installation / Fixing / Provision of Outdoor type Thermoplastic Modular Panel enclosure with transparent Polycarbonate Lid, shock proof, IP65 (Weather Proof), rust proof, dust proof, water proof, corrosion proof having internally Embedded gasket on both lid and flap suitable to fix Single Phase / Three Phase Energy Meter in suitable base plate and having a provision for Fuse / MCB cutout with suitable transparent hinged flap opening for operating MCB along with complete tamper proof SEALING facility. - 300mmx300mmx214mm
| Each | 4737.6 | 4737.6 | 1.0 | False | None | None | False | None | False | 4737.6 | 0 | 3254051 | 112728 | None | UNI CSR 2023-24 PWD Vol-6 Elec Uti Part-III It No | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system.
| Each | 3133.2 | 3133.2 | 26.0 | False | None | None | False | None | False | 81463.2 | 0 | 3254052 | 112728 | None | UNI CSR 2023-24 PWD Vol-6 Elec Uti Part-III It No | Supplying and drawing PVC flexible one pair telephone unarmoured tinned copper cable. - 2Pair
| Mtr | 22.05 | 22.05 | 200.0 | False | None | None | False | None | False | 4410.0 | 0 | 3254053 | 112728 | None | UNI CSR 2023-24 PWD Vol-6 Elec Uti Part-III It No | Supplying & fixing of I/O socket with back box - Double I/o
| Each | 577.5 | 577.5 | 12.0 | False | None | None | False | None | False | 6930.0 | 0 | 3254054 | 112728 | None | UNI CSR 2023-24 PWD Vol-6 Elec Uti Part-III It No | Supplying & Fixing of …mtrs Cat6 Patch Cable - 2mtr
| Each | 269.85 | 269.85 | 12.0 | False | None | None | False | None | False | 3238.2 | 0 | 3254055 | 112728 | None | UNI CSR 2023-24 PWD Vol-6 Elec Uti Part-III It No | Supplying & Fixing of Patch panel for LAN cabling - 16 Port 10/100 patch panel
| Each | 3202.5 | 3202.5 | 1.0 | False | None | None | False | None | False | 3202.5 | 0 | 3254056 | 112728 | None | UNI CSR 2023-24 PWD Vol-6 Elec Uti Part-III It No | Supplying and fixing of MDF krone junction box with KRONE Module / Telephone - cable termination. - 10 Pair
| m | 362.25 | 362.25 | 6.0 | False | None | None | False | None | False | 2173.5 | 0 | 3254057 | 112728 | None | UNI CSR 2023-24 PWD Vol-6 Elec Uti Part-III It No | Supplying of .feet PVC Batten with integrated LED tube
.W with high quality diffuser with Life of 25000 burning hours & 70 lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. -LED light fighting 1 x4- 20 22 w
| Each | 724.5 | 724.5 | 33.0 | False | None | None | False | None | False | 23908.5 | 0 | 3254058 | 112728 | None | UNI CSR 2023-24 PWD Vol-6 Elec Uti Part-III It No | Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with .W System Power consumption. LED Efficiency130lm w, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABL CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. - LED Streetlight 40watts
| Each | 4225.2 | 4225.2 | 1.0 | False | None | None | False | None | False | 4225.2 | 0 | 3254059 | 112728 | None | UNI CSR 2023-24 PWD Vol-6 Elec Uti Part-III It No | Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. - On wall / ceiling / Rafter / Girders
| Each | 128.1 | 128.1 | 33.0 | False | None | None | False | None | False | 4227.3 | 0 | 3254060 | 112728 | None | UNI CSR 2023-24 PWD Vol-6 Elec Uti Part-III It No | Fixing halogen/metal halide / SVL / IL / LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires.
| Each | 170.1 | 170.1 | 1.0 | False | None | None | False | None | False | 170.1 | 0 | 3254061 | 112728 | None | UNI CSR 2023-24 PWD Vol-6 Elec Uti Part-III It No | Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S' hook with fan regulator to the existing board together with supplying and fixing 5 amps. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring.
| Each | 179.55 | 179.55 | 26.0 | False | None | None | False | None | False | 4668.3 | 0 | 3254062 | 112728 | None | UNI CSR 2023-24 PWD Vol-6 Elec Uti Part-III It No | Fixing halogen/metal halide / SVL / IL / LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires.
| Km | 92838.9 | 92838.9 | 0.08 | False | None | None | False | None | False | 7427.112 | 0 | 3254063 | 112728 | None | UNI CSR 2023-24 Escoms Vol-6 Distribution Material | Supplying of 1.1 KV LT UG cable having aluminum conductor PVC insulated, extruded inner sheathed, galvanized, steel strip (except 2CX10Sq.mm wire armoured) confirming to IS-3975:1990 (No. of Strip indicated in GTP) & extruded PVC outer sheathed armoured cable with specified IS-1554 Part-1:1988 2 core 6 sqmm
| Km | 66576.3 | 66576.3 | 0.02 | False | None | None | False | None | False | 1331.526 | 0 | 3254064 | 112728 | None | UNI CSR 2023-24 Escoms Vol-6 Distribution Labour P | Labour charges for laying of 1.1 KV class UG cable in existing trench GI pipe / stoneware pipe / on wall / on pole as required.In existing trench/duct. 2.5 sqmm to 25 sqmm
| Km | 1246.35 | 1246.35 | 0.1 | False | None | None | False | None | False | 124.635 | 0 | 3254065 | 112728 | None | UNI CSR2021-22 Bescoms Vol-6 Distribution Labour | Earth work Excavation for cable trench of 0.5m to 0.75 mtr width and Depth upto 1 Mtrs including trial pits, depositing on bank upto a lead of 50 Mtrs , Supplying and Displaying necessary Danger Boards and Lighting , Using sight Rails and Sign Boards at every 100 Mtrs wherever necessary as directed. In soil (Ordinary) (1x60x0.50x0.75 = 22.50 CMT)
| cm | 273.0 | 273.0 | 22.5 | False | None | None | False | None | False | 6142.5 | 0 | 3254066 | 112728 | None | UNI CSR 2021-22 Bescoms Vol-6 Distribution Labour | Providing and filling sand in excavated trench to cover already laid UG cable to a depth of 150mm all-round the cable. (1x60x0.50x0.75 = 22.50 CMT)
| cm | 60.9 | 60.9 | 22.5 | False | None | None | False | None | False | 1370.25 | 0 | 3254067 | 112728 | None | UNI CSR 2023-24 PWD Vol-6 Elec Uti Part-III It No | Supplying and fixing Trivector Meter suitable for operation LT operation and -CT operated meter in polycarbonate body in class 0.5 accuracy as per IS 14697 and completely wired.
| Each | 4609.5 | 4609.5 | 1.0 | False | None | None | False | None | False | 4609.5 | 0 | 3254068 | 112728 | None | UNI CSR 2023-24 PWD Vol-6 Elec Uti Part-III It No | Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc. using 40mm dia 2.9mm thick 2.5 mtr long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode. The funnel should be enclosed in a CC chamber of 400x400x400mm with a cast iron cover. The earth electrode shall have staggered holes of 12mm dia and the electrode should be covered 150mm all-round with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts.
| Each | 3685.5 | 3685.5 | 2.0 | False | None | None | False | None | False | 7371.0 | 0 |
| 1717999503000 | 0 | None | None | Buildings | Construction Of New School Building in UGHPS Goudanabhavi Village in Maski taluk of Raichur district. Under - KARNATAKA SAMAGRA SHIKSHANA SCHEME/2022-23 | 11375226.95 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3254652 | 112747 | None | PWD CSR VOL I - 2023-24. I. No.2.5.2 P.No.16 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 7185.15 | 7185.15 | 36.23 | False | None | None | False | None | False | 260317.9845 | 0 | 3254545 | 112747 | None | PWD DSR 2023-24 V -1 P.NO-08 I.NO-1.12 | Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work.In all kinds of soils upto 300 mm depth
| Cum | 99.75 | 99.75 | 240.0 | False | None | None | False | None | False | 23940.0 | 0 | 3254582 | 112747 | None | PWD DSR 2023-24 V -1 P.NO-08 I.NO-1.14.1 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work.In all kinds of soils Depth upto 3 m
| Cum | 107.1 | 107.1 | 32.4 | False | None | None | False | None | False | 3470.04 | 0 | 3254627 | 112747 | None | PWD Ele. SR 2023-24, P. No-02, It No- 1.2.1 | Supplying heavy gauge PVC conduit pipe 19/20mm dia 2mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary
| Mtr | 69.3 | 69.3 | 120.0 | False | None | None | False | None | False | 8316.0 | 0 | 3254527 | 112747 | None | PWD SR VOL I 2023-24 I.No.1.5.2 P.No.6 | Earth work excavation by manual means for drains,canals, waste weir draft, approach channels, key trench, foundation of Bridges and such similar works, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, excavatedsurface leveled and sides neatly dressed disposing off or leveling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour,
| Cum | 467.25 | 467.25 | 1.88 | False | None | None | False | None | False | 878.43 | 0 | 3254502 | 112747 | None | PWD SR VOL II 2023-24. I. No. 13.34 P.NO.123 | WATER SUPPLY WORKS
P/F STORAGE TANK
Providing and placing on terrace (on all floor levels), polyethylene water storage tanks IS: 12701 marked, with cover and suitable locking arrangements and making necessary holes for inlet, outlet and over flow pipes but without fittings and the base support for tank
| Ltr | 9.45 | 9.45 | 2000.0 | False | None | None | False | None | False | 18900.0 | 0 | 3254685 | 112747 | None | UNI CSR 2023-24 PWD Vol-6 Elec Uti Part-III It No | Supplying heavy gauge PVC conduit pipe 19/20mm dia 2mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc., and fixing using inverted wood plugs in case of RCC ceiling and RCC wall / stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws.
| Mtr | 69.3 | 69.3 | 500.0 | False | None | None | False | None | False | 34650.0 | 0 | 3254532 | 112747 | None | WS & UGD Vol V CSR-2023-24 No.13.11.3 P No-151 | Providing,supplying to work site, Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications,as per necessary ammendments and instructions of engineer incharge of work. For 3 HP
| Each | 27205.5 | 27205.5 | 1.0 | False | None | None | False | None | False | 27205.5 | 0 | 3254653 | 112747 | None | PWD CSR VOL I - 2023-24. I. No. 9 P.No. 111 | Additionalities for Formwork, Centering & Scaffolding for Column 70%
| Cum | 5029.61 | 5029.61 | 4.55 | False | None | None | False | None | False | 22884.7255 | 0 | 3254583 | 112747 | None | PWD DSR 2023-24 V -1 P.NO-06 I.NO-1.5.2 | Earth work excavation by manual means for drains,canals, waste weir draft,
approach channels, key trench, foundation of Bridges and such similar works,
as per drawing and technical specifications, including setting out, shoring,
strutting, barricading, caution lights, excavated surface leveled and sides neatly
dressed disposing off or leveling the excavated stuff or sorting & stacking the
selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost
of labour, tools, usage & other appurtenances required to complete the work.Depth exceeding 1.5m, but not exceeding 3 m
| Cum | 467.25 | 467.25 | 17.87 | False | None | None | False | None | False | 8349.7575 | 0 | 3254546 | 112747 | None | PWD DSR 2023-24 V -1 P.NO-08 I.NO-1.14.1 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work.In all kinds of soils Depth upto 3 m
| Cum | 107.1 | 107.1 | 376.88 | False | None | None | False | None | False | 40363.848 | 0 | 3254628 | 112747 | None | PWD Ele. SR 2023-24, P. No-01, It No- 1.2.2 | 25mm dia 2mm thick
| Mtr | 81.9 | 81.9 | 90.0 | False | None | None | False | None | False | 7371.0 | 0 | 3254528 | 112747 | None | PWD SR VOL I 2023-24 I.No.1.12 P.No.6 | Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth
not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps
and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. | Cum | 99.75 | 99.75 | 56.25 | False | None | None | False | None | False | 5610.9375 | 0 | 3254503 | 112747 | None | PWD SR VOL II 2023-24. I. No. 13.34 P.NO.123 | P/F STORAGE TANK
Providing and placing on terrace (on all floor levels), polyethylene water storage tanks IS: 12701 marked, with cover and suitable locking arrangements and making necessary holes for inlet, outlet and over flow pipes but without fittings and the base support for tank
| Ltr | 9.45 | 9.45 | 1000.0 | False | None | None | False | None | False | 9450.0 | 0 | 3254686 | 112747 | None | UNI CSR 2023-24 PWDV ol-6 Elec Uti Part-III It No | 25mm dia 2mm thick
| Mtr | 81.9 | 81.9 | 50.0 | False | None | None | False | None | False | 4095.0 | 0 | 3254533 | 112747 | None | WS & UGD -Vol V CSR - 2023-24 i. No. 13.22.3 ,P | Submersible Cables:
Supply and delivery at site Brand new best make PVC insulated cable of Flat 3 core (sheathed) of nominal cross sectional area as per IS 694-1990 with ISI Mark and as per its latest amendments. (1X3X4 m2)
| Mtr | 141.75 | 141.75 | 90.0 | False | None | None | False | None | False | 12757.5 | 0 | 3254654 | 112747 | None | PWD CSR VOL I - 2023-24. I. No. 14 P.No. 112 | Additionalities for Formwork, Centering & Scaffolding for Lintel&Roof beam 60% | Cum | 4311.09 | 4311.09 | 11.53 | False | None | None | False | None | False | 49706.8677 | 0 | 3254547 | 112747 | None | PWD DSR 2023-24 V -1 P.NO-15 I.NO-2.1.2 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates
| Cum | 5947.2 | 5947.2 | 63.21 | False | None | None | False | None | False | 375922.512 | 0 | 3254584 | 112747 | None | PWD DSR 2023-24 V -1 P.NO-7 I.NO-1.9 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of
foundations and other similar works etc. in layers not exceeding 20cm in depth,
consolidating each deposited layer by ramming and watering, lead up to 50 m
and lift upto 1.5 m
| Cum | 279.3 | 279.3 | 8.1 | False | None | None | False | None | False | 2262.33 | 0 | 3254629 | 112747 | None | PWD Ele. SR 2023-24, P.No-01,It No- 1.3.1 | Supplying heavy gauge PVC Conduit Pipe 19/20mm dia 2mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary.
| Mtr | 71.4 | 71.4 | 40.0 | False | None | None | False | None | False | 2856.0 | 0 | 3254529 | 112747 | None | PWD SR VOL I 2023-24 I.No.2.1.2 P.No.15 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness,well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formworkshall be paid separately)
| Cum | 5947.2 | 5947.2 | 1.25 | False | None | None | False | None | False | 7434.0 | 0 | 3254504 | 112747 | None | PWD SR VOL II 2023-24. I. No. 13.33.5 P.NO.123 | Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS 15778 having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, this includes jointing of pipes and fittings with one step solvent cement, trenching, refilling & testing of joints complete. (external work).
| Mtr | 500.85 | 500.85 | 15.0 | False | None | None | False | None | False | 7512.75 | 0 | 3254687 | 112747 | None | UNI CSR 2023-24 PWD Vol-6 Elec UtiPart-IIIIt No | Supplying heavy gauge PVC Conduit Pipe 19/20mm dia 2mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary.
| Mtr | 71.4 | 71.4 | 100.0 | False | None | None | False | None | False | 7140.0 | 0 | 3254534 | 112747 | None | WS & UGD -Vol V CSR -2023-24 I.No. 13.23.1 ,P N | Pressure Guage:
Supply and delivery at site of brand new best make pressure gauge bourdon type as per IS 778/1984 with ISI Mark and as per its latest amendments. a.63mm
| Each | 436.8 | 436.8 | 1.0 | False | None | None | False | None | False | 436.8 | 0 | 3254655 | 112747 | None | PWD CSR VOL I - 2023-24. I. No. 15 P.No. 112 | Additionalities for Formwork, Centering & Scaffolding for Slab 50% | Cum | 3592.58 | 3592.58 | 17.0 | False | None | None | False | None | False | 61073.86 | 0 | 3254585 | 112747 | None | PWD CSR VOL I 2023-24. I. No. 2.1.2 P.No. 15 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates
| Cum | 5947.2 | 5947.2 | 14.78 | False | None | None | False | None | False | 87899.616 | 0 | 3254548 | 112747 | None | PWD DSR 2023-24 V -1 P.NO-15 I.NO-2.2.3 | Providing and laying in position Cement Concrete for all Foundation works. The granite /trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
| Cum | 6652.8 | 6652.8 | 26.78 | False | None | None | False | None | False | 178161.984 | 0 | 3254530 | 112747 | None | PWD DSR 2023-24 vol-1 I.No.2.2.3 P No.15 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6652.8 | 6652.8 | 7.55 | False | None | None | False | None | False | 50228.64 | 0 | 3254630 | 112747 | None | PWD Ele.SR 2023-24, P.No-01, It No- 1.3.2 | 25mm dia 2mm thick
| Mtr | 84.0 | 84.0 | 80.0 | False | None | None | False | None | False | 6720.0 | 0 | 3254505 | 112747 | None | PWD SR VOL II 2023-24. I. No. 13.33.4 P.NO.122 | Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, this includes jointing of pipes and fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete. (external work). - 32mm nominal doa pipes
| m | 390.6 | 390.6 | 15.0 | False | None | None | False | None | False | 5859.0 | 0 | 3254688 | 112747 | None | UNI CSR 2023-24 PWD Vol-6 Elec Uti Part-III It No | Supplying heavy gauge PVC Conduit Pipe 25mm dia 2mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary.
| Mtr | 82.95 | 82.95 | 20.0 | False | None | None | False | None | False | 1659.0 | 0 | 3254535 | 112747 | None | WS & UGD -Vol V - 2023-24 No. 27.1 ,P No-162 | Gate Valve:
Supply and delivery at site of brand new best make gate valve as per IS 778/1984 with ISI Mark and as per its latest amendments size 50mm
| Each | 1312.5 | 1312.5 | 1.0 | False | None | None | False | None | False | 1312.5 | 0 | 3254656 | 112747 | None | PWD CSR VOL I - 2023-24. I. No. 16 P.No. 112 | Additionalities for Formwork, Centering & Scaffolding for Stair case 50% | Cum | 3592.58 | 3592.58 | 3.14 | False | None | None | False | None | False | 11280.7012 | 0 | 3254549 | 112747 | None | PWD CSR VOL I - 2023-24. I. No.2 P.No. 111 | Additionalities for Formwork, Centering & Scaffolding for Footing 8%
| Cum | 532.22 | 532.22 | 28.44 | False | None | None | False | None | False | 15136.3368 | 0 | 3254586 | 112747 | None | PWD CSR VOL I 2023-24. I. No. 2.1.2 P.No. 15 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates
| Cum | 5947.2 | 5947.2 | 1.17 | False | None | None | False | None | False | 6958.224 | 0 | 3254631 | 112747 | None | PWD Ele. SR 2022-23, P.No-03, It No- 2.2.1 | Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2X1.5Sq.mm Cable confirming to the GTP without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet. Short point upto 3Mtr from tapping point to out let via switch box
| Point | 263.55 | 263.55 | 12.0 | False | None | None | False | None | False | 3162.6 | 0 | 3254531 | 112747 | None | PWD SR VOL I 2023-24, I. No. 2.11a P.No.18 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.
| Tonne | 93929.85 | 93929.85 | 0.38 | False | None | None | False | None | False | 35693.343 | 0 | 3254506 | 112747 | None | PWD SR VOL II 2023-24. I. No. 13.32.3 P.NO.122 | Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, i/c including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes and fittings with one step solvent cement & the cost of cutting chases and making good the same including testing of joints complete as per direction of engineer in charge. concealed work, including cutting chases and making good the walls etc. - 25mm nominal dia pipes
| m | 500.85 | 500.85 | 15.0 | False | None | None | False | None | False | 7512.75 | 0 | 3254689 | 112747 | None | UNI CSR 2023-24 PWD Vol-6 Elec Uti Part-III It No | Supplying And Fixing Metal Fan Box with Round Hook.
| Each | 122.85 | 122.85 | 26.0 | False | None | None | False | None | False | 3194.1 | 0 | 3254536 | 112747 | None | WS & UGD -Vol V - 2023-24 No. 13.43.1 P No-157 | Outdoor type Board: upto 6 HP
Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOLDirect Online Starter 2) S-D- Star Delta Starter
| Each | 9975.0 | 9975.0 | 1.0 | False | None | None | False | None | False | 9975.0 | 0 | 3254587 | 112747 | None | PWD CSR VOL 2 2023-24. Sl. No. 5.2 , P.No. 09 | Providing Coursed rubble masonry (first sort) with hard stone in foundation
and plinth with Cement mortar 1:6 (1 cement : 6 coarse sand
| Cum | 6948.9 | 6948.9 | 6.62 | False | None | None | False | None | False | 46001.718 | 0 | 3254657 | 112747 | None | PWD CSR VOL I - 2023-24. I. No. 2.4.1 P.No. 16 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, cluding all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.Mix 1:2:4 (M15) Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6724.2 | 6724.2 | 1.07 | False | None | None | False | None | False | 7194.894 | 0 | 3254550 | 112747 | None | PWD DSR 2023-24 V -1 P.NO-15 I.NO-2.4.3 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The nite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, ding
all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
| Cum | 6652.8 | 6652.8 | 23.16 | False | None | None | False | None | False | 154078.848 | 0 | 3254632 | 112747 | None | PWD Ele. SR 2022-23, P.No-03, It No- 2.2.2 | Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch box
| Point | 379.05 | 379.05 | 20.0 | False | None | None | False | None | False | 7581.0 | 0 | 3254507 | 112747 | None | PWD SR VOL II 2023-24. I. No. 13.32.2 | Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, i/c including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes and fittings with one step solvent cement & the cost of cutting chases and making good the same including testing of joints complete as per direction of engineer in charge. concealed work, including cutting chases and making good the walls etc. - 20mm nominal dia pipes
| m | 397.95 | 397.95 | 15.0 | False | None | None | False | None | False | 5969.25 | 0 | 3254690 | 112747 | None | UNI CSR 2023-24 PWD Vol-6 Elec UtiPart-IIIIt No | Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2X1.5Sq.mm Cable confirming to the GTP without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet. GROUP A - Short point upto 3Mtr from tapping point to out let via switch box
| Point | 282.45 | 282.45 | 26.0 | False | None | None | False | None | False | 7343.7 | 0 | 3254537 | 112747 | None | WS & UGD -Vol V - 2023-24 No. 13.25 ,P No-162 | Power capacitor
Supply and delivery at site best indigenous brand new power capacitor as per IS 2834/1986 with latest amendments with KPTCL authorities and erection, electrification and commissioning of the same at the location of respective pump sets.
| Kvar | 577.5 | 577.5 | 3.0 | False | None | None | False | None | False | 1732.5 | 0 | 3254588 | 112747 | None | PWD CSR VOL 2 2023-24. Sl. No. 5.3 , P.No. 09 | Providing Coursed rubble masonry (second sort) with hard stone in
foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)
| Cum | 6515.25 | 6515.25 | 5.07 | False | None | None | False | None | False | 33032.3175 | 0 | 3254658 | 112747 | None | PWD CSR VOL I - 2023-24. I. No. 2.5.2 P.No.16 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregateS | Cum | 7185.15 | 7185.15 | 0.56 | False | None | None | False | None | False | 4023.684 | 0 | 3254551 | 112747 | None | PWD CSR VOL I - 2023-24. I. No.2 P.No. 111 | Additionalities for Formwork, Centering & Scaffolding for Plinth Beam 50%
| Cum | 3326.4 | 3326.4 | 23.17 | False | None | None | False | None | False | 77072.688 | 0 | 3254633 | 112747 | None | PWD Ele. SR 2022-23, P. No-03, It No- 2.2.3 | Long point above 6Mtr upto 10Mtr from tapping point to out let via switch box
| Point | 569.1 | 569.1 | 20.0 | False | None | None | False | None | False | 11382.0 | 0 | 3254508 | 112747 | None | PWD SR VOL II 2023-24. I. No. 13.2.1 P.NO.117 | P/F BRASS BIBCOCK
| Nos | 300.3 | 300.3 | 15.0 | False | None | None | False | None | False | 4504.5 | 0 | 3254691 | 112747 | None | UNI CSR 2023-24 PWD Vol-6 Elec UtiPart-IIIIt No | Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch box
| Point | 397.95 | 397.95 | 31.0 | False | None | None | False | None | False | 12336.45 | 0 | 3254538 | 112747 | None | WS & UGD -Vol V CSR-2023-24 I. No. 32 ,P No-162 | MCB
Supply and delivery at site delivery of best indigenous brand new MCB (Miniature Circuit Breakers) of required capacity as per IS 88228/1978 and its latest amendments and with ISI Mark of 6/10/16/20/25/40 Amps with scalable box.
| 3 Poles | 1207.5 | 1207.5 | 1.0 | False | None | None | False | None | False | 1207.5 | 0 | 3254552 | 112747 | None | PWD CSR VOL I - 2023-24. I. No. 1.11 P.No. 7 | Filling approved earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m
| Cum | 454.65 | 454.65 | 416.67 | False | None | None | False | None | False | 189439.0155 | 0 | 3254589 | 112747 | None | PWD CSR VOL I 2021-22. I. No. 1.8 P.No. 7 | Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work.
| Cum | 472.82 | 472.82 | 68.58 | False | None | None | False | None | False | 32425.9956 | 0 | 3254634 | 112747 | None | PWD Ele. SR 2022-23, P.No-03, It No- 2.3.2 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 1.5sqmm.
| Mtr | 27.3 | 27.3 | 250.0 | False | None | None | False | None | False | 6825.0 | 0 | 3254659 | 112747 | None | PWD SR 2023-24 V-1 Page No .112 SI No 19 | Addendum I Percentage Additionalities for Formwork, Centering & Scaffoldin Above the Item for Chejja45% | Cum | 3233.32 | 3233.32 | 0.56 | False | None | None | False | None | False | 1810.6592 | 0 | 3254509 | 112747 | None | PWD SR VOL II 2023-24. I. No. 13.5.2 | P/F BRASS BALL VALVE
| Nos | 329.7 | 329.7 | 10.0 | False | None | None | False | None | False | 3297.0 | 0 | 3254692 | 112747 | None | UNI CSR 2023-24 PWD Vol-6 Elec UtiPart-IIIIt No | Long point above 6Mtr upto 10Mtr from tapping point to out let via switch box
| Point | 582.75 | 582.75 | 6.0 | False | None | None | False | None | False | 3496.5 | 0 | 3254539 | 112747 | None | WS & UGD -Vol V CSR -2023-24 No. 13.32 | HDPE Pipe:
Supplying, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc. Note: Upto 110mm dia Coil shall be used. For Grade PE80 PN6.0 : PE80 (PN 6.0 / 6 Kg/cm2) a. 63mm
| Mtr | 198.45 | 198.45 | 65.0 | False | None | None | False | None | False | 12899.25 | 0 | 3254553 | 112747 | None | PWD CSR VOL II - 2023-24. I. No. 4.1 P.No. 5 | Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated
earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications.
| Sqm | 123.9 | 123.9 | 142.1 | False | None | None | False | None | False | 17606.19 | 0 | 3254635 | 112747 | None | PWD Ele. SR 2022-23, P.No-03, It No- 2.3.3 | 2.5sqmm.
| Mtr | 42.0 | 42.0 | 250.0 | False | None | None | False | None | False | 10500.0 | 0 | 3254660 | 112747 | None | PWD SR VOL I 2023-24, I. No. 2.11a P.No.18 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. | Tonne | 93929.85 | 93929.85 | 2.31 | False | None | None | False | None | False | 216977.9535 | 0 | 3254510 | 112747 | None | PWD SR VOL II 2023-24. I. No. 14.7.2 | P/F WASH BASIN
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a single 15mm C.P. brass pillar tap
| Each | 2689.05 | 2689.05 | 4.0 | False | None | None | False | None | False | 10756.2 | 0 | 3254590 | 112747 | None | PWD SR- VOL I - 2023-24. I. No. 2.2.3 P.No. 15 | Providing and laying in position Cement Concrete for all Foundation works.
The granite/trap/basalt crushed graded coarse aggregates and fine aggregates
as per relevant IS Codes machine mixed with super plasticizers laid in finished
layers, well compacted using needle vibrators, including all lead & lifts, cost
of all materials, quality confirming to the requirements of relevant IS codes,
labour, Usage charges of machinery, curing and all the other appurtenances
required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates"
| Cum | 6652.8 | 6652.8 | 2.4 | False | None | None | False | None | False | 15966.72 | 0 | 3254693 | 112747 | None | UNI CSR 2023-24 PWD Vol-6 Elec Uti Part-IIIIt N | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 - 1.5sqmm.
| Mtr | 27.3 | 27.3 | 1000.0 | False | None | None | False | None | False | 27300.0 | 0 | 3254540 | 112747 | None | WS & UGD Works Vol V CSR for the 2021-22 No. 13.32 | Errection,Electrification and commisioning works of Submersible Pump sets:
Labour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all items including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges,tools and equipments etc., involved in the job as per specifications, with necessary tests as per specifications, with testing of as per instructions of engineer incharge of work.
| Job | 6825.0 | 6825.0 | 1.0 | False | None | None | False | None | False | 6825.0 | 0 | 3254554 | 112747 | None | PWD CSR VOL I - 2023-24. I. No. 2.4.1P.No.16 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including
all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.Mix 1:2:4 (M15) Using 20 mm nominal size graded crushed coarse aggregates
| Sqm | 6724.2 | 6724.2 | 2.5 | False | None | None | False | None | False | 16810.5 | 0 | 3254661 | 112747 | None | PWD CSR VOL II - 2023-24. I. No.6.5 P.No.13 | Providing Brick work with common burnt clay machine moulded perforated bricks of class designation 5.0 conforming to IS: 2222 in superstructure above plinth level in cement mortar 1:6 (1 cement : 6 coarse sand) With Non modular bricks including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. | Cum | 11525.85 | 11525.85 | 38.21 | False | None | None | False | None | False | 440402.7285 | 0 | 3254636 | 112747 | None | PWD Ele. SR 2022-23, P.No-03, It No- 2.3.4 | 4.0sqmm.
| Mtr | 61.95 | 61.95 | 100.0 | False | None | None | False | None | False | 6195.0 | 0 | 3254591 | 112747 | None | PWD SR VOL I 2023-24. I. No. 3 P.No.111 | Appendix I Additionalities for Formwork, Centering & Scaffolding for Footing 5%
| Cum | 506.88 | 506.88 | 2.4 | False | None | None | False | None | False | 1216.512 | 0 | 3254511 | 112747 | None | PWD SR VOL II 2023-24. I. No. 13.8.2.2 | PVC connection pipe
| Nos | 115.5 | 115.5 | 4.0 | False | None | None | False | None | False | 462.0 | 0 | 3254694 | 112747 | None | UNI CSR 2023-24 PWD Vol-6 Elec Uti Part-IIIIt No | 2.5sqmm.
| Mtr | 44.1 | 44.1 | 1000.0 | False | None | None | False | None | False | 44100.0 | 0 | 3254541 | 112747 | None | WS & UGD -Vol V CSR -2023-24 No. 13.33 | Pump sets:
Labour charges for erection of indoor type panel board and meter board units with all necessary materials and labour tools and equipments including cement concrete for foundation/bed etc,complete as per specification, with testing of as per instructions of engineer incharge of work.
| Job | 1417.5 | 1417.5 | 1.0 | False | None | None | False | None | False | 1417.5 | 0 | 3254555 | 112747 | None | PWD CSR VOL I - 2023-24. I. No. 2.5.2 P.No.16 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
| Cum | 7185.15 | 7185.15 | 1.01 | False | None | None | False | None | False | 7257.0015 | 0 | 3254662 | 112747 | None | PWD CSR VOL II - 2023-24. I. No.11.10.1 P.No.79 | Fixing standard steel glazed doors, windows and ventilators in walls, including fixing of float glass panes with glazing clips and special metalsash putty of approved make, or metal beading with screws, (only steel windows, glass panes cut to size and glazing clips or metal beading with screws, shall be supplied by department free of cost: Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Kg | 46.2 | 46.2 | 464.4 | False | None | None | False | None | False | 21455.28 | 0 | 3254637 | 112747 | None | PWD Ele. SR 2022-23, P.No-6, It No- 3.14.6 | 6Amps lamp holder
| No | 66.15 | 66.15 | 12.0 | False | None | None | False | None | False | 793.8 | 0 | 3254592 | 112747 | None | PWD SR VOL I 2023-24. I. No. 2.2.3 P.No. 15 | Providing and laying in position Cement Concrete for all Foundation works.
The granite/trap/basalt crushed graded coarse aggregates and fine aggregates
as per relevant IS Codes machine mixed with super plasticizers laid in finished
layers, well compacted using needle vibrators, including all lead & lifts, cost
of all materials, quality confirming to the requirements of relevant IS codes,
labour, Usage charges of machinery, curing and all the other appurtenances
required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
| Cum | 6652.8 | 6652.8 | 0.63 | False | None | None | False | None | False | 4191.264 | 0 | 3254512 | 112747 | None | PWD SR VOL II 2023-24. I. No. 14.3.2 Page No. 131 | SANITARY WORK
WATER CLOSET
Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid
| Each | 6095.25 | 6095.25 | 16.0 | False | None | None | False | None | False | 97524.0 | 0 | 3254695 | 112747 | None | UNI CSR 2023-24 PWD Vol-6 Elec Uti Part-III It No | 4.0sqmm.
| Mtr | 66.15 | 66.15 | 75.0 | False | None | None | False | None | False | 4961.25 | 0 | 3254542 | 112747 | None | WS & UGD -Vol V CSR -2023-24 No. 13.38.2 | Providing,Supplying and fixing suitable for 1.1 KV class UG cable filled with necessary bitumen insulating compound complete with terminals clamps,bolts,nuts and washers etc. with necessary materials and labour tools and equipments as per instructions of engineer incharge of work. Sqm
| Each | 472.5 | 472.5 | 1.0 | False | None | None | False | None | False | 472.5 | 0 | 3254556 | 112747 | None | PWD CSR VOL I - 2023-24. I. No.15 P.No. 112 | Additionalities for Formwork, Centering & Scaffolding for chejja 45%
| Cum | 3233.32 | 3233.32 | 1.35 | False | None | None | False | None | False | 4364.982 | 0 | 3254663 | 112747 | None | PWD CSR VOL II - 2023-24. I. No.11.37.1 P.No.89 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness (weight not less than 10kg/ m²) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge | Sqm | 1037.4 | 1037.4 | 15.48 | False | None | None | False | None | False | 16058.952 | 0 | 3254638 | 112747 | None | PWD Ele. SR 2022-23, P.No-5, It No- 3.1.1 | Supplying 6A flush type socket and 6 amps flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3654 - 6Amps 2 Way
| Each | 127.05 | 127.05 | 10.0 | False | None | None | False | None | False | 1270.5 | 0 | 3254593 | 112747 | None | PWD SR VOL I 2023-24. I. No. 3 P.No.111 | Appendix I Additionalities for Formwork, Centering & Scaffolding for Column 70%
| Cum | 4656.96 | 4656.96 | 0.63 | False | None | None | False | None | False | 2933.8848 | 0 | 3254513 | 112747 | None | PWD SR VOL II 2023-24. No. 14.29 Page No. 136 | GULLY TRAP
| Each | 49.35 | 49.35 | 10.0 | False | None | None | False | None | False | 493.5 | 0 | 3254696 | 112747 | None | UNI CSR 2023-24 PWDVol-6 Elec Uti Part-III It No | Supplying 6A flush type socket and 6 amps flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3654 - 6Amps 2 Way
| Each | 134.4 | 134.4 | 4.0 | False | None | None | False | None | False | 537.6 | 0 | 3254543 | 112747 | None | WS & UGD -Vol V CSR -2023-24 No. 13.27.1 | Collar:
Supply and delivery of galvanized mild steel tubes of 6mtr standard length heavy duty (C Class) as per IS 1239 (Part-I) 1990 with latest amendments with ISI Mark (one end fitted with Heavy Duty collar and other end fitted with protective cover) a.50 mm
| Each | 3202.5 | 3202.5 | 1.0 | False | None | None | False | None | False | 3202.5 | 0 | 3254514 | 112747 | None | PWD CSR VOL I 2023-24I. No. 1.6.1 Page No.6 | EARTH WORK EXCAVATION
Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work. In all kinds of soils. Depth upto 1.50m
| Cum | 508.2 | 508.2 | 46.08 | False | None | None | False | None | False | 23417.856 | 0 | 3254664 | 112747 | None | PWD CSR VOL II - 2023-24. I. No.12.13.1 P.No.100 | Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. | Cum | 103755.75 | 103755.75 | 0.32 | False | None | None | False | None | False | 33201.84 | 0 | 3254557 | 112747 | None | PWD DSR 2021-22 V - 1 I.No. 2.11 a | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.
| Tonne | 93929.85 | 93929.85 | 17.79 | False | None | None | False | None | False | 1671012.0315 | 0 | 3254639 | 112747 | None | PWD Ele. SR 2022-23, P.No-5, It No- 3.6.1 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 6Amps one way switch.
| Each | 92.4 | 92.4 | 10.0 | False | None | None | False | None | False | 924.0 | 0 | 3254594 | 112747 | None | PWD SR VOL I 2023-24. I. No. 2.4.3 P.No. 16 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
| Cum | 6652.8 | 6652.8 | 4.3 | False | None | None | False | None | False | 28607.04 | 0 | 3254697 | 112747 | None | UNI CSR 2023-24PWD Vol-6 Elec Uti Part-III It No | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 4-5 Way
| Each | 143.85 | 143.85 | 10.0 | False | None | None | False | None | False | 1438.5 | 0 | 3254544 | 112747 | None | WS & UGD -Vol V CSR- 2023-24 No.13.39 | Earthing
Earthing: Supplying and fixing and wiring earth electrode for grounding circuits IC cutouts and other equipments on the meter board in the pit. The pits should be filled up with equal proportion of salt and charcoal 150mm around the pipe to complete depth. The connection from the pipe to the conduits etc. is to established through GI wire of sizes as per clause 7.3.3 of IS 732 using 12mm bolts, nuts, washers and check nuts, the pipe shall have 16 through holes of 12mm dia.
| Job | 3937.5 | 3937.5 | 1.0 | False | None | None | False | None | False | 3937.5 | 0 | 3254558 | 112747 | None | PWD CSR VOL II - 2023-24. I. No. 5.2 P.No. 9 | Providing Coursed rubble masonry (first sort) with hard stone in foundation
and plinth with Cement mortar 1:6 (1 cement : 6 coarse sand
| Cum | 6948.9 | 6948.9 | 55.24 | False | None | None | False | None | False | 383857.236 | 0 | 3254665 | 112747 | None | PWD CSR VOL II - 2023-24. I. No.12.15 P.No.100 | Providing and fixing in position fully panelled Matti/Nandi wood shutters for doors with, stiles and rails of 35mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. (excluding cost of fixtures ) | Sqm | 6904.8 | 6904.8 | 5.04 | False | None | None | False | None | False | 34800.192 | 0 | 3254640 | 112747 | None | PWD Ele. SR 2022-23, P.No-5, It No- 3.6.8 | 16Amps one way switch.
| Each | 261.45 | 261.45 | 10.0 | False | None | None | False | None | False | 2614.5 | 0 | 3254595 | 112747 | None | PWD SR VOL I 2023-24. I. No.3 P.No.111 | Appendix I Additionalities for Formwork, Centering & Scaffolding for Grade & Plinth Beam 50%
| Cum | 3326.4 | 3326.4 | 4.3 | False | None | None | False | None | False | 14303.52 | 0 | 3254698 | 112747 | None | UNI CSR 2023-24 PWD Vol-6 Elec Uti Part-III It No | 8 - Way
| Each | 229.95 | 229.95 | 8.0 | False | None | None | False | None | False | 1839.6 | 0 | 3254515 | 112747 | None | WS&UGD CSR 2023-24 I.No.16.9 SOR CODE: T130B P.No. | BRICK MASONRY FOR INSPECTION CHAMBER
Constructing brick masonry chamber of internal dimension 600x600 mm and depth of 600 mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150 mm thick with 1:3:6, lastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75 mm thick for fixing CI cover & frame etc. excluding the cost of CI frame and cover.
| Each | 5726.7 | 5726.7 | 1.09 | False | None | None | False | None | False | 6242.103 | 0 | 3254559 | 112747 | None | PWD CSR VOL II - 2023-24. I. No. 5.3 P.No. 9 | Providing Coursed rubble masonry (second sort) with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand))
| Cum | 6515.25 | 6515.25 | 42.67 | False | None | None | False | None | False | 278005.7175 | 0 | 3254666 | 112747 | None | PWD CSR VOL II - 2023-24. I. No.7.6 P.No.21 | Providing and fixing 15 cm wide, 45 cm overall semi-circular plain G.S.sheet gutter with iron brackets 40x3mm size, bolts, nuts and washers etc., including making necessary connections with rain water pipes complete. (0.63 mm thick with zinc coating not less than 275 g/m²) | Rmtr | 677.25 | 677.25 | 21.0 | False | None | None | False | None | False | 14222.25 | 0 | 3254641 | 112747 | None | PWD Ele. SR 2022-23, P. No-5, It No- 3.6.11 | 6/16Amps universal socket.
| Each | 261.45 | 261.45 | 1.0 | False | None | None | False | None | False | 261.45 | 0 | 3254596 | 112747 | None | PWD SR for Buildings VOL I for the year 2023-24. I | Providing and laying in position Cement Concrete for all Super structures of
building , Road works, Water works, Irrigation works & super structure works
of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse
aggregates and fine aggregates as per relevant IS Codes machine mixed with
super plasticisers laid in layers, well compacted using needle vibrators. The
cost includes all lead & lifts, cost of all materials, quality confirming to the
requirements of relevant IS codes , labour, Usage charges of machinery, curing
and all other appurtenances required to complete the work as per technical
specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
| Cum | 7185.15 | 7185.15 | 3.01 | False | None | None | False | None | False | 21627.3015 | 0 | 3254699 | 112747 | None | UNI CSR 2023-24 PWD Vol-6 Elec Uti Part-III It No | 10-12 Way
| Each | 274.05 | 274.05 | 10.0 | False | None | None | False | None | False | 2740.5 | 0 | 3254516 | 112747 | None | WS &UGD CSR 2023-24. No16.1.2 P.No.184 | P/F STONEWARE PIPE
Supplying, lowering, laying, jointing, testing and commissioning of Glazed Stone Ware Pipes of following dia, conforming to IS 651:1992, IS 4127 with latest amendments, including conveying to work site, caulking with hemp dipped in tar and jointing with CM 1:1.5 using OPC, perfect linking and curing for 10 days and testing with water etc. with all lead, lifts and as per Technical Specifications. The cost to include the cost of all jointing materials, necessary survey works for laying of sewer lines etc. complete. The contractor will make own arrangements for procuring water for testing. 150 mm dia. pipes
| m | 610.05 | 610.05 | 10.0 | False | None | None | False | None | False | 6100.5 | 0 | 3254560 | 112747 | None | PWD CSR VOL II - 2023-24. I. No. 6.5 P.No.13 | Providing Brick work with common burnt clay machine moulded perforated bricks of class designation 5.0 conforming to IS: 2222 in superstructure above plinth level in cement mortar 1:6 (1 cement : 6 coarse sand) With Non modular bricks including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.
| Cum | 11525.85 | 11525.85 | 86.52 | False | None | None | False | None | False | 997216.542 | 0 | 3254667 | 112747 | None | PWD CSR VOL II - 2023-24. I. No.7.25.1 | PProviding and fixing plain multipurpose cement board(Hight pressure steam cured) with suitable screws for cement particle board in ceiling etc. complete 6 mm thick Cement fiber board as per IS: 14862
| Sqm | 666.75 | 666.75 | 10.0 | False | None | None | False | None | False | 6667.5 | 0 | 3254642 | 112747 | None | PWD Ele. SR 2022-23, P.No-5, It No- 3.4.2 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall . 4-5Way
| Each | 144.9 | 144.9 | 4.0 | False | None | None | False | None | False | 579.6 | 0 | 3254597 | 112747 | None | PWD SR VOL I 2023-24. I. No.3 P.No.111 | Appendix I Additionalities for Formwork, Centering & Scaffolding for Column 70%
| Cum | 5029.61 | 5029.61 | 3.01 | False | None | None | False | None | False | 15139.1261 | 0 | 3254700 | 112747 | None | UNI CSR 2023-24 PWD Vol-6 Elec Uti Part-IIIIt No | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. - 4-5 Module
| Each | 183.75 | 183.75 | 10.0 | False | None | None | False | None | False | 1837.5 | 0 | 3254517 | 112747 | None | WS &UGD CSR 2023-24. No 16.5.1 SOR CODE: T070A P.N | Labour charges for laying and jointing glazed stone ware pipes of 0.6m length and of specified dia., of tested quality conforming to IS 651 of 1965 including caulking with hemp yarn, jointing with CM 1:2 and testing with water etc. complete for: (Rate to include cost of jointing materials and
trasportation of pipes from store work site ) | m | 74.55 | 74.55 | 10.0 | False | None | None | False | None | False | 745.5 | 0 | 3254561 | 112747 | None | PWD CSR VOL II - 2023-24. I. No.11.10.1 P.No.79 | Fixing standard steel glazed doors, windows and ventilators in walls, including fixing of float glass panes with glazing clips and special metalsash putty of approved make, or metal beading with screws, (only steel windows, glass panes cut to size and glazing clips or metal beading with screws, shall be supplied by department free of cost: Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.
| Kg | 46.2 | 46.2 | 1350.0 | False | None | None | False | None | False | 62370.0 | 0 | 3254668 | 112747 | None | PWD CSR VOL II - 2023-24. I. No.6.13 P.No.14 | Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in foundations and plinth in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work | Sqm | 1024.8 | 1024.8 | 37.58 | False | None | None | False | None | False | 38511.984 | 0 | 3254643 | 112747 | None | PWD Ele. SR 2022-23, P. No-5, It No- 3.4.4 | 8Way
| Each | 262.5 | 262.5 | 1.0 | False | None | None | False | None | False | 262.5 | 0 | 3254598 | 112747 | None | PWD SR VOL I 2023-24. I. No. 2.5.2 P.No. 16 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
| Cum | 7185.15 | 7185.15 | 1.98 | False | None | None | False | None | False | 14226.597 | 0 | 3254701 | 112747 | None | UNI CSR 2023-24 PWD Vol-6 Elec Uti -III It No | 8 - Module
| Each | 298.2 | 298.2 | 8.0 | False | None | None | False | None | False | 2385.6 | 0 | 3254518 | 112747 | None | WS &UGD CSR 2023-24. I.No.10.1.7 P.No.113 | Supplying PVC ring tight pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials)with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: PVC pipes 110 mm outer dia., 6 kg/sqcm & class 3
| m | 413.7 | 413.7 | 30.0 | False | None | None | False | None | False | 12411.0 | 0 | 3254519 | 112747 | None | PWD CSR VOL I 2023-24 I. No.2.1.2 P.No.15 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates
| Cum | 5947.2 | 5947.2 | 2.0 | False | None | None | False | None | False | 11894.4 | 0 | 3254562 | 112747 | None | PWD CSR VOL II - 2023-24. I. No.11.37.1 P.No.89 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in
basic item):With float glass panes of 4.0 mm thickness (weight not less than 10kg/ m²) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge
| Kg | 1037.4 | 1037.4 | 27.0 | False | None | None | False | None | False | 28009.8 | 0 | 3254669 | 112747 | None | PWD CSR VOL II - 2023-24. I. No.9.21.3 P.No.14 | Providing and laying Vitrified tiles with thickness 9-10 mm in floor with different sizes with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately) Size of Tile 1000x1000 mm | Sqm | 1418.55 | 1418.55 | 130.08 | False | None | None | False | None | False | 184524.984 | 0 | 3254644 | 112747 | None | PWD Ele. SR 2022-23, P. No-5, It No- 3.4.5 | 10-12Way
| Each | 341.25 | 341.25 | 1.0 | False | None | None | False | None | False | 341.25 | 0 | 3254599 | 112747 | None | PWD SR VOL I 2023-24. I. No.14 P.No.112 | Appendix I Additionalities for Formwork, Centering & Scaffolding for Lintel Beam 60%
| Cum | 4311.09 | 4311.09 | 1.98 | False | None | None | False | None | False | 8535.9582 | 0 | 3254702 | 112747 | None | UNI CSR 2023-24 PWD Vol-6 Elec Uti Part-III It No | 10-12 Module
| Each | 361.2 | 361.2 | 10.0 | False | None | None | False | None | False | 3612.0 | 0 | 3254563 | 112747 | None | PWD CSR VOL II - 2023-24. I. No.12.15 P.No.100 | Providing and fixing in position fully panelled Matti/ Nandi wood shutters for doors with, stiles and rails of 35mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. (excluding cost of fixtures ) the Engineer-in-Charge. | Sqm | 6904.8 | 6904.8 | 15.12 | False | None | None | False | None | False | 104400.576 | 0 | 3254670 | 112747 | None | PWD CSR VOL II - 2023-24. I. No.8.9 P.No.42 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 404.25 | 404.25 | 202.52 | False | None | None | False | None | False | 81868.71 | 0 | 3254645 | 112747 | None | PWD Ele. SR 2022-23, P. No-5, It No- 3.5.2 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. - 4 Module
| Each | 183.75 | 183.75 | 4.0 | False | None | None | False | None | False | 735.0 | 0 | 3254600 | 112747 | None | PWD SR VOL I 2023-24. I. No. 2.5.2 P.No. 16 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
| Cum | 7185.15 | 7185.15 | 2.36 | False | None | None | False | None | False | 16956.954 | 0 | 3254520 | 112747 | None | PWD SR VOL II 2023-24 I.No. 6.8 P.No.14 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.
| Cum | 8367.45 | 8367.45 | 8.92 | False | None | None | False | None | False | 74637.654 | 0 | 3254703 | 112747 | None | UNI CSR 2023-24 PWD Vol-6 Elec Uti Part-III It No | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 6Amps One way switch.
| Each | 107.1 | 107.1 | 80.0 | False | None | None | False | None | False | 8568.0 | 0 | 3254564 | 112747 | None | PWD CSR VOL II - 2023-24. I. No.7.6 P.No.21 | Providing and fixing 15 cm wide, 45 cm overall semi-circular plain G.S. sheet gutter with iron brackets 40x3mm size, bolts, nuts and washers etc., including making necessary connections with rain water pipes complete. (0.63 mm thick with zinc coating not less than 275 g/m²)
| Rmtr | 677.25 | 677.25 | 14.0 | False | None | None | False | None | False | 9481.5 | 0 | 3254671 | 112747 | None | PWD CSR VOL II - 2023-24. I. No.8.6.1 P.No.42 | Providing 12 mm cement plaster with Cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer in-charge. | Sqm | 339.15 | 339.15 | 98.66 | False | None | None | False | None | False | 33460.539 | 0 | 3254646 | 112747 | None | PWD Ele. SR 2022-23, P.No-5, It No- 3.5.4 | 8Module
| Each | 317.1 | 317.1 | 2.0 | False | None | None | False | None | False | 634.2 | 0 | 3254601 | 112747 | None | PWD SR VOL I 2023-24. I. No.14 P.No.112 | Appendix I Additionalities for Formwork, Centering & Scaffolding for Roof Beam 20%
| Cum | 4311.09 | 4311.09 | 2.36 | False | None | None | False | None | False | 10174.1724 | 0 | 3254521 | 112747 | None | PWD SR VOL II 2023-24 I. No.6.13 P.No.14 | Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:4 (1 cement :4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.
| Sqm | 1024.8 | 1024.8 | 5.4 | False | None | None | False | None | False | 5533.92 | 0 | 3254704 | 112747 | None | UNI CSR 2023-24 PWD Vol-6 Elec Uti Part-III It No | Stepped Fan Regulator Two Module
| Each | 374.85 | 374.85 | 26.0 | False | None | None | False | None | False | 9746.1 | 0 | 3254522 | 112747 | None | PWD CSR VOL I 2023-24, I. No. 2.3.1 P.No.16 | Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
| Cum | 7966.98 | 7966.98 | 1.51 | False | None | None | False | None | False | 12030.1398 | 0 | 3254565 | 112747 | None | PWD CSR VOL II - 2023-24. I. No.7.25.1 P.No | Providing and fixing Green Board As Per Market Rate complete.
| Sqm | 666.75 | 666.75 | 6.0 | False | None | None | False | None | False | 4000.5 | 0 | 3254672 | 112747 | None | PWD CSR VOL II - 2023-24. I. No.8.25 P.No.45 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 143.85 | 143.85 | 98.66 | False | None | None | False | None | False | 14192.241 | 0 | 3254647 | 112747 | None | PWD Ele. SR 2022-23, P. No-5, It No- 3.5.5 | 10-12Module
| Each | 381.15 | 381.15 | 2.0 | False | None | None | False | None | False | 762.3 | 0 | 3254602 | 112747 | None | PWD SR VOL I 2023-24. I. No. 2.5.2 P.No. 16 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
| Cum | 7185.15 | 7185.15 | 7.69 | False | None | None | False | None | False | 55253.8035 | 0 | 3254705 | 112747 | None | UNI CSR 2023-24 PWD Vol-6 Elec Uti Part-III It No | 16 A One Way Switch
| Each | 189.0 | 189.0 | 4.0 | False | None | None | False | None | False | 756.0 | 0 | 3254566 | 112747 | None | PWD CSR VOL II - 2023-24. I. No.6.13 P.No.14 | Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in foundations and plinth in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.
| Sqm | 1024.8 | 1024.8 | 86.91 | False | None | None | False | None | False | 89065.368 | 0 | 3254673 | 112747 | None | PWD CSR VOL II - 2023-24. I. No.8.28 P.No.45 | Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 93.45 | 93.45 | 155.62 | False | None | None | False | None | False | 14542.689 | 0 | 3254648 | 112747 | None | PWD Ele. SR 2022-23, P. No-38 , It No- 11.13.2 | Supplying and fixing of slim patty fitting, made out of CRCA
Sheet metal body with locking type holder completely wired. Excluding Ballast & Fluorescent Tube. 1 x 4' Tube light fitting.
| Each | 255.15 | 255.15 | 8.0 | False | None | None | False | None | False | 2041.2 | 0 | 3254603 | 112747 | None | PWD SR for Buildings VOL I for the year 2023-24. I | Appendix I Additionalities for Formwork, Centering & Scaffolding for Roof Slab 50%
| Cum | 3592.58 | 3592.58 | 7.69 | False | None | None | False | None | False | 27626.9402 | 0 | 3254523 | 112747 | None | PWD SR VOL II 2023-24, I. No. 8.8 P.No.42 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 486.94 | 486.94 | 36.4 | False | None | None | False | None | False | 17724.616 | 0 | 3254706 | 112747 | None | UNI CSR 2023-24 PWD Vol-6 Ele Uti Part-III It No | 6 16 A Universal Socket
| Each | 247.8 | 247.8 | 16.0 | False | None | None | False | None | False | 3964.8 | 0 | 3254674 | 112747 | None | PWD CSR VOL II - 2023-24. I. No.8.45.1 P.No.49 | Varnishing with varnish of approved brand and manufacture :Two coats of glue sizing with copal varnish over an under coat of flatting varnish to give an even shade and produce a smooth dry and mat surface including preparing the surface after thorougly cleaning oil, grease, dirt and foreign mattersand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 180.6 | 180.6 | 15.48 | False | None | None | False | None | False | 2795.688 | 0 | 3254567 | 112747 | None | PWD CSR VOL II - 2023-24. I. No.8.8 P.No. | Providing and laying Vitrified tiles with thickness 9-10 mm in floor with different sizes with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately) Size of Tile 1000x1000 mm
| Sqm | 1418.55 | 1418.55 | 386.21 | False | None | None | False | None | False | 547858.1955 | 0 | 3254649 | 112747 | None | PWD Ele. SR 2022-23, P. No-39 , It No- 12.12.1 | Supplying and fixing/replacing of fluorescent tube. 18 to 40W
| Each | 96.6 | 96.6 | 8.0 | False | None | None | False | None | False | 772.8 | 0 | 3254604 | 112747 | None | PWD SR VOL II 2023-24. I. No.6.13 P.No. 14 | Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in foundations and plinth in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.
| Cum | 1024.8 | 1024.8 | 13.23 | False | None | None | False | None | False | 13558.104 | 0 | 3254524 | 112747 | None | PWD SR VOL II2023-24. I. No. 13.40 | Providing & Fixing square - mouth S.W. guly trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I cover 180x150 mm size P type & with non-modular common burnt clay bricks of designation 3.5 & frame of 300 x 300mm size (inside) the weight of cover to be not less than4.50 kg and frame to be not less than 2.70 Kg as per standard design :
| Each | 2820.3 | 2820.3 | 1.0 | False | None | None | False | None | False | 2820.3 | 0 | 3254707 | 112747 | None | UNI CSR2023-24 PWD-6 Elec Uti Part-III It No | TV / Telephone Socket
| Each | 163.8 | 163.8 | 2.0 | False | None | None | False | None | False | 327.6 | 0 | 3254675 | 112747 | None | PWD CSR VOL II - 2023-24. I. No.8.45.1 P.No.49 | Varnishing with varnish of approved brand and manufacture :Two coats of glue sizing with copal varnish over an under coat of flatting varnish to give an even shade and produce a smooth dry and mat surface including preparing the surface after thorougly cleaning oil, grease, dirt and foreign mattersand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 180.6 | 180.6 | 5.04 | False | None | None | False | None | False | 910.224 | 0 | 3254568 | 112747 | None | PWD CSR VOL II - 2023-24. I. No.8.8 P.No.42 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications
and as per directions of Engineer-in-charge
| Sqm | 389.55 | 389.55 | 225.14 | False | None | None | False | None | False | 87703.287 | 0 | 3254650 | 112747 | None | PWD Ele.SR 2022-23, P. No-13, It No- 5.17.1 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32Amps SP
| Each | 549.15 | 549.15 | 6.0 | False | None | None | False | None | False | 3294.9 | 0 | 3254525 | 112747 | None | PWD SR VOL I 2023-24, I. No. 2.11a P.No.18 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, achinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire /soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.
| Tonne | 93929.85 | 93929.85 | 0.1 | False | None | None | False | None | False | 9392.985 | 0 | 3254605 | 112747 | None | PWD SR VOL II 2023-24. I. No.6.13 P.No. 14 | Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:4 (1 cement :4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.
| Sqm | 1024.8 | 1024.8 | 119.66 | False | None | None | False | None | False | 122627.568 | 0 | 3254708 | 112747 | None | UNI CSR 2023-24 PWD Vol-6 Elec Uti Part-III It No | RJ 45/I.O Outlet Cat-6
| Each | 353.85 | 353.85 | 12.0 | False | None | None | False | None | False | 4246.2 | 0 | 3254526 | 112747 | None | PWD CSR VOL I 2023-24, I. No.6 P.No.111 | Additionalities for Formwork, Centering & Scaffolding 20% of I.No. 21
| Cum | 1593.4 | 1593.4 | 1.51 | False | None | None | False | None | False | 2406.034 | 0 | 3254676 | 112747 | None | PWD CSR VOL II - 2023-24. I. No.11.28 P.No.85 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Kg | 593.25 | 593.25 | 207.0 | False | None | None | False | None | False | 122802.75 | 0 | 3254569 | 112747 | None | PWD CSR VOL II - 2023-24. I. No.8.25 P.No.45 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 143.85 | 143.85 | 319.44 | False | None | None | False | None | False | 45951.444 | 0 | 3254651 | 112747 | None | PWD Ele.SR 2022-23, P. No-13, It No- 5.17.4 | 6-32 Amps DP
| Each | 1158.15 | 1158.15 | 6.0 | False | None | None | False | None | False | 6948.9 | 0 | 3254606 | 112747 | None | PWD SR VOL II 2023-24. I. No.6.16 P.No. 15 | Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry.
| Sqm | 99.75 | 99.75 | 119.66 | False | None | None | False | None | False | 11936.085 | 0 | 3254709 | 112747 | None | UNI CSR 2023-24 PWD Vol-6 Elec Uti Part-III It No | Supplying of Switch disconnector fuse unit (TPN) HRC type (but without HRC fuses). With AC-23A duty and as per IS-13947. - 63Amps
| Each | 2427.6 | 2427.6 | 1.0 | False | None | None | False | None | False | 2427.6 | 0 | 3254570 | 112747 | None | PWD CSR VOL II - 2023-24. I. No.8.28 P.No.45 | Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 93.45 | 93.45 | 253.58 | False | None | None | False | None | False | 23697.051 | 0 | 3254677 | 112747 | None | PWD Ele- SR 2023-24, P. No-01, It No- 1.2.1 | Electrical Item
Concealed Conduit System :Supplying heavy gauge PVC conduit pipe . mm dia.mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary - 25mm dia 2mm thick. | Mtr | 69.3 | 69.3 | 25.0 | False | None | None | False | None | False | 1732.5 | 0 | 3254607 | 112747 | None | PWD SR VOL II 2023-24. I. No.8.6.1 P.No. 42 | Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 339.15 | 339.15 | 196.77 | False | None | None | False | None | False | 66734.5455 | 0 | 3254710 | 112747 | None | UNI CSR 2023-24 PWD Vol-6 Elec Uti Part-III It No | Supplying and fixing regular MCCB distribution Panel confirming to IS 8828, on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing of suitable type capacity MCCB's as an incomer for 3 phase Double door with necessary bus bar completely wired to use on 440Volts 3phase 4 wire powder coated painting etc., complete with a provision for fixing of single/three phase suitable capacity MCCB/MCB's as outgoings confirming to IS8828. - 12-Way
| Each | 16305.45 | 16305.45 | 1.0 | False | None | None | False | None | False | 16305.45 | 0 | 3254571 | 112747 | None | PWD CSR VOL II - 2023-24. I. No.8.45.1 P.No.49 | Varnishing with varnish of approved brand and manufacture :Two coats of glue sizing with copal varnish over an under coat of flatting varnish to give an even shade and produce a smooth dry and mat surface including preparing the surface after thorougly cleaning oil, grease, dirt and foreign mattersand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 180.6 | 180.6 | 54.72 | False | None | None | False | None | False | 9882.432 | 0 | 3254678 | 112747 | None | PWD Ele-SR 2023-24, P. No-01, It No- 1.3.1 | Supplying heavy gauge PVC Conduit Pipe 19/20mm dia 2mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. | Mtr | 71.4 | 71.4 | 40.0 | False | None | None | False | None | False | 2856.0 | 0 | 3254608 | 112747 | None | PWD SR VOL II 2023-24. I. No.8.9 P.No. 42 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 404.25 | 404.25 | 107.68 | False | None | None | False | None | False | 43529.64 | 0 | 3254711 | 112747 | None | UNI CSR 2023-24 PWD Vol-6 Elec Uti Part-III It No | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. - 6-32Amps SP
| Each | 435.75 | 435.75 | 4.0 | False | None | None | False | None | False | 1743.0 | 0 | 3254572 | 112747 | None | PWD CSR VOL II - 2023-24. I. No.8.45.1 P.No.49 | Varnishing with varnish of approved brand and manufacture :Two coats of glue sizing with copal varnish over an under coat of flatting varnish to give an even shade and produce a smooth dry and mat surface including preparing the surface after thorougly cleaning oil, grease, dirt and foreign mattersand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 180.6 | 180.6 | 25.2 | False | None | None | False | None | False | 4551.12 | 0 | 3254679 | 112747 | None | PWD Ele- SR 2023-24, P. No-03, It No- 2.2.1 | Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2X1.5Sq.mm Cable confirming to the GTP without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet. Short point upto 3Mtr from tapping point to out let via switch box | Point | 263.55 | 263.55 | 12.0 | False | None | None | False | None | False | 3162.6 | 0 | 3254609 | 112747 | None | PWD SR VOL II 2023-24. I. No.8.7 P.No. 42 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 384.3 | 384.3 | 138.56 | False | None | None | False | None | False | 53248.608 | 0 | 3254712 | 112747 | None | UNI CSR 2023-24 PWD Vol-6 Elec Uti Part-III It No | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. - 5-32 Amps DP
| Each | 775.95 | 775.95 | 2.0 | False | None | None | False | None | False | 1551.9 | 0 | 3254573 | 112747 | None | PWD CSR VOL II - 2023-24. I. No.11.28 P.No.85 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.
| Kg | 593.25 | 593.25 | 238.5 | False | None | None | False | None | False | 141490.125 | 0 | 3254680 | 112747 | None | PWD Ele-SR 2023-24, P.No-22, It No- 6.3.2 | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system. - 48" Sweep (1200mm) Regular model | Each | 3182.55 | 3182.55 | 4.0 | False | None | None | False | None | False | 12730.2 | 0 | 3254610 | 112747 | None | PWD SR VOL II 2023-24. I. No.8.51 P.No. 50 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.
| Sqm | 105.0 | 105.0 | 244.7 | False | None | None | False | None | False | 25693.5 | 0 | 3254713 | 112747 | None | UNI CSR 2023-24 PWD Vol-6 Elec Uti Part-III It No | Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG MS enclosure.I - Single Door -12 Way SP &N
| Each | 1956.15 | 1956.15 | 1.0 | False | None | None | False | None | False | 1956.15 | 0 | 3254574 | 112747 | None | PWD CSR VOL I - 2023-24. I. No. 2.5.2 P.No. 16 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical
specifications. .M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
| Cum | 7185.15 | 7185.15 | 108.2 | False | None | None | False | None | False | 777433.23 | 0 | 3254681 | 112747 | None | PWD Ele-SR 2023-24, P.No-22, It No- 2.1.5 | Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. - SThree outlet in a row, above 6Mts upto 10Mtr from tapping point to out let via switches | Point | 1086.75 | 1086.75 | 20.0 | False | None | None | False | None | False | 21735.0 | 0 | 3254611 | 112747 | None | PWD SR VOL II 2023-24. I. No.12.13.1 P.No. 100 | Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications.
| Cum | 103755.75 | 103755.75 | 0.15 | False | None | None | False | None | False | 15563.3625 | 0 | 3254714 | 112747 | None | UNI CSR 2023-24nPWD Vol-6 Elec Uti Part-III It No | Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker [ELMCB] 240/450V up to 300mA sensitivity on existing wood/panel board. - 63 Amps 4 pole
| Each | 3210.9 | 3210.9 | 1.0 | False | None | None | False | None | False | 3210.9 | 0 | 3254575 | 112747 | None | PWD CSR VOL I - 2023-24. I. No.9 P.No. 111 | Additionalities for Formwork, Centering & Scaffolding for Column 70%
| Cum | 5029.61 | 5029.61 | 10.6 | False | None | None | False | None | False | 53313.866 | 0 | 3254682 | 112747 | None | PWD Ele-SR 2023-24, P.No-22, It No- 1.4.4 | Supplying and fixing sheet metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc. - 180x90x65mm | Each | 169.05 | 169.05 | 10.0 | False | None | None | False | None | False | 1690.5 | 0 | 3254612 | 112747 | None | PWD SR VOL II 2023-24. I. No.12.54.1 P.No. 104 | Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge.
| Sqm | 333.9 | 333.9 | 91.2 | False | None | None | False | None | False | 30451.68 | 0 | 3254715 | 112747 | None | UNI CSR 2023-24 PWD Vol-6 Elec Uti Part-III It No | Fabricating supplying and mounting MS box made out … SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete. - 14SWG
| Each | 0.53 | 0.53 | 4000.0 | False | None | None | False | None | False | 2120.0 | 0 | 3254576 | 112747 | None | PWD CSR VOL I - 2023-24. I. No.14 P.No. 112 | Additionalities for Formwork, Centering & Scaffolding for Lintle&Roof Beam 60%
| Cum | 4311.09 | 4311.09 | 31.7 | False | None | None | False | None | False | 136661.553 | 0 | 3254683 | 112747 | None | PWD Ele-SR 2023-24, P.No-3, It No- 1.6.1 | Supplying and flush mounting teak wooden box without front plank, made of not less than 12mm thick wood, after due groove cutting, finishing with necessary cement plastering complete. - 12"x12"x3" (300x300x76mm)
| Each | 126.0 | 126.0 | 8.0 | False | None | None | False | None | False | 1008.0 | 0 | 3254613 | 112747 | None | PWD SR VOL II 2023-24. I. No.12.57.6 P.No. 105 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per specification. 35 mm thick both side commercial
| Sqm | 3488.1 | 3488.1 | 3.49 | False | None | None | False | None | False | 12173.469 | 0 | 3254716 | 112747 | None | UNI CSR 2023-24 PWD Vol-6 Elec Uti Part-III It No | Supply and Installation / Fixing / Provision of Outdoor type Thermoplastic Modular Panel enclosure with transparent Polycarbonate Lid, shock proof, IP65 (Weather Proof), rust proof, dust proof, water proof, corrosion proof having internally Embedded gasket on both lid and flap suitable to fix Single Phase / Three Phase Energy Meter in suitable base plate and having a provision for Fuse / MCB cutout with suitable transparent hinged flap opening for operating MCB along with complete tamper proof SEALING facility. - 300mmx300mmx214mm
| Each | 4737.6 | 4737.6 | 1.0 | False | None | None | False | None | False | 4737.6 | 0 | 3254577 | 112747 | None | PWD CSR VOL I - 2023-24. I. No.15 P.No. 112 | Additionalities for Formwork, Centering & Scaffolding for Roof Slab 50%
| Cum | 3592.58 | 3592.58 | 49.73 | False | None | None | False | None | False | 178659.0034 | 0 | 3254684 | 112747 | None | PWD Ele-SR 2023-24, P.No-22, It No- 11.13.1 | Supplying and fixing of slim patty fitting, made out of CRCA Sheet metal body with locking type holder completely wired. Excluding Ballast & Fluorescent Tube. 769 1 x 4' Tube light fitting. | Each | 194.25 | 194.25 | 6.0 | False | None | None | False | None | False | 1165.5 | 0 | 3254614 | 112747 | None | PWD SR VOL II 2023-24. I. No.12.55.1 P.No. 104 | Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges. with one side prelam
| Nos | 2484.3 | 2484.3 | 25.2 | False | None | None | False | None | False | 62604.36 | 0 | 3254717 | 112747 | None | UNI CSR 2023-24 PWD Vol-6 Elec Uti Part-III It No | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system.
| Each | 3133.2 | 3133.2 | 26.0 | False | None | None | False | None | False | 81463.2 | 0 | 3254578 | 112747 | None | PWD CSR VOL I - 2023-24. I. No.16 P.No. 112 | Additionalities for Formwork, Centering & Scaffolding for Stair case 50%
| Cum | 3592.58 | 3592.58 | 5.9 | False | None | None | False | None | False | 21196.222 | 0 | 3254615 | 112747 | None | PWD SR VOL II 2023-24. I. No.12.51 P.No. 104 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications.
| Nos | 1066.8 | 1066.8 | 2.0 | False | None | None | False | None | False | 2133.6 | 0 | 3254718 | 112747 | None | UNI CSR 2023-24 PWD Vol-6 Elec Uti Part-III It No | Supplying and drawing PVC flexible one pair telephone unarmoured tinned copper cable. - 2Pair
| Mtr | 22.05 | 22.05 | 200.0 | False | None | None | False | None | False | 4410.0 | 0 | 3254579 | 112747 | None | PWD CSR VOL II - 2023-24. I. No.8.6.1 P.No.42 | Providing 12 mm cement plaster with Cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer in-charge | Sqm | 339.15 | 339.15 | 400.97 | False | None | None | False | None | False | 135988.9755 | 0 | 3254616 | 112747 | None | PWD SR VOL II 2023-24. I. No.12.85 P.No. 109 | Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made | Sqm | 6004.95 | 6004.95 | 6.84 | False | None | None | False | None | False | 41073.858 | 0 | 3254719 | 112747 | None | UNI CSR 2023-24 PWD Vol-6 Elec Uti Part-III It No | Supplying & fixing of I/O socket with back box - Double I/o
| Each | 577.5 | 577.5 | 12.0 | False | None | None | False | None | False | 6930.0 | 0 | 3254580 | 112747 | None | PWD CSR VOL II - 2023-24. I. No.12.13.1 P.No.100 | Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. | Cum | 103755.75 | 103755.75 | 2.27 | False | None | None | False | None | False | 235525.5525 | 0 | 3254617 | 112747 | None | PWD SR VOL II 2023-24. I. No.12.34A P.No. 86 | Providing and fixing M.S. grills of required pattern in frames of windows
etc. with M.S. flats, square or round bars etc. including priming coat with
approved steel primer all complete. Fixed to steel windows by welding
| Kgs | 176.4 | 176.4 | 143.64 | False | None | None | False | None | False | 25338.096 | 0 | 3254720 | 112747 | None | UNI CSR 2023-24 PWD Vol-6 Elec Uti Part-III It No | Supplying & Fixing of …mtrs Cat6 Patch Cable - 2mtr
| Each | 269.85 | 269.85 | 12.0 | False | None | None | False | None | False | 3238.2 | 0 | 3254581 | 112747 | None | PWD CSR VOL II - 2023-24. I. No.8.16.1 P.No.43 | Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment
| Mtr | 35.7 | 35.7 | 211.37 | False | None | None | False | None | False | 7545.909 | 0 | 3254618 | 112747 | None | PWD SR VOL II 2023-24. I. No.9.11A P.No.60 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete.
| Sqm | 933.45 | 933.45 | 47.93 | False | None | None | False | None | False | 44740.2585 | 0 | 3254721 | 112747 | None | UNI CSR 2023-24 PWD Vol-6 Elec Uti Part-III It No | Supplying & Fixing of Patch panel for LAN cabling - 16 Port 10/100 patch panel
| Each | 3202.5 | 3202.5 | 1.0 | False | None | None | False | None | False | 3202.5 | 0 | 3254619 | 112747 | None | PWD SR VOL II 2023-24. I. No. 9.39 P.No. 65 | Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications.
| Sqm | 1521.45 | 1521.45 | 136.08 | False | None | None | False | None | False | 207038.916 | 0 | 3254722 | 112747 | None | UNI CSR 2023-24 PWD Vol-6 Elec Uti Part-III It No | Supplying and fixing of MDF krone junction box with KRONE Module / Telephone - cable termination. - 10 Pair
| m | 362.25 | 362.25 | 6.0 | False | None | None | False | None | False | 2173.5 | 0 | 3254620 | 112747 | None | PWD SR VOL II 2023-24. I. No. 8.33.3 P.No. 47 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @ 0.80 ltr/10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 145.95 | 145.95 | 6.84 | False | None | None | False | None | False | 998.298 | 0 | 3254723 | 112747 | None | UNI CSR 2023-24 PWD Vol-6 Elec Uti Part-III It No | Supplying of .feet PVC Batten with integrated LED tube
.W with high quality diffuser with Life of 25000 burning hours & 70 lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. -LED light fighting 1 x4- 20 22 w
| Each | 724.5 | 724.5 | 33.0 | False | None | None | False | None | False | 23908.5 | 0 | 3254621 | 112747 | None | PWD SR VOL II 2023-24. I. No. 8.33.1 P.No. 46 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Special primer applied @ 0.75 ltr /10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 165.9 | 165.9 | 196.77 | False | None | None | False | None | False | 32644.143 | 0 | 3254724 | 112747 | None | UNI CSR 2023-24 PWD Vol-6 Elec Uti Part-III It No | Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with .W System Power consumption. LED Efficiency130lm w, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABL CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. - LED Streetlight 40watts
| Each | 4225.2 | 4225.2 | 1.0 | False | None | None | False | None | False | 4225.2 | 0 | 3254622 | 112747 | None | PWD SR VOL II 2023-24. I. No. 8.33.1 P.No. 46 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Special primer applied @ 0.75 ltr /10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 165.9 | 165.9 | 47.93 | False | None | None | False | None | False | 7951.587 | 0 | 3254725 | 112747 | None | UNI CSR 2023-24 PWD Vol-6 Elec Uti Part-III It No | Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. - On wall / ceiling / Rafter / Girders
| Each | 128.1 | 128.1 | 33.0 | False | None | None | False | None | False | 4227.3 | 0 | 3254623 | 112747 | None | PWD SR VOL II 2023-24. I. No. 8.30 P.No. 46 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including riming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 182.7 | 182.7 | 107.68 | False | None | None | False | None | False | 19673.136 | 0 | 3254726 | 112747 | None | UNI CSR 2023-24 PWD Vol-6 Elec Uti Part-III It No | Fixing halogen/metal halide / SVL / IL / LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires.
| Each | 170.1 | 170.1 | 1.0 | False | None | None | False | None | False | 170.1 | 0 | 3254624 | 112747 | None | PWD CSR VOL II 2023-24. I. No. 8.19.1 P.No. 44 | Providing Flush/ Ruled pointing: Pointing on stone work with cement mortar 1:3 (1 cement : 3 fine sand) after raking joints to depth nicely lining, including cost of materials, labour, curing as per specifications and as per directions of Engineer-in-charge.
| Sqm | 267.75 | 267.75 | 20.4 | False | None | None | False | None | False | 5462.1 | 0 | 3254727 | 112747 | None | UNI CSR 2023-24 PWD Vol-6 Elec Uti Part-III It No | Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S' hook with fan regulator to the existing board together with supplying and fixing 5 amps. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring.
| Each | 179.55 | 179.55 | 26.0 | False | None | None | False | None | False | 4668.3 | 0 | 3254625 | 112747 | None | PWD SR VOL I 2023-24, I. No. 2.11a P.No.18 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. | Tonne | 93929.85 | 93929.85 | 1.73 | False | None | None | False | None | False | 162498.6405 | 0 | 3254728 | 112747 | None | UNI CSR 2023-24 PWD Vol-6 Elec Uti Part-III It No | Fixing halogen/metal halide / SVL / IL / LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires.
| Km | 92838.9 | 92838.9 | 0.08 | False | None | None | False | None | False | 7427.112 | 0 | 3254626 | 112747 | None | PWD CSR VOL II 2023-24. I. No. 8.49 P.No. 49 | Lettering with black Japan paint of approved brand and manufacture to give an even shade including preparing the surface after thoroughly cleaning the surface to remove all dirt, dust and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
| cm | 4.2 | 4.2 | 1500.0 | False | None | None | False | None | False | 6300.0 | 0 | 3254729 | 112747 | None | UNI CSR 2023-24 Escoms Vol-6 Distribution Material | Supplying of 1.1 KV LT UG cable having aluminum conductor PVC insulated, extruded inner sheathed, galvanized, steel strip (except 2CX10Sq.mm wire armoured) confirming to IS-3975:1990 (No. of Strip indicated in GTP) & extruded PVC outer sheathed armoured cable with specified IS-1554 Part-1:1988 2 core 6 sqmm
| Km | 66576.3 | 66576.3 | 0.02 | False | None | None | False | None | False | 1331.526 | 0 | 3254730 | 112747 | None | UNI CSR 2023-24 Escoms Vol-6 Distribution Labour P | Labour charges for laying of 1.1 KV class UG cable in existing trench GI pipe / stoneware pipe / on wall / on pole as required.In existing trench/duct. 2.5 sqmm to 25 sqmm
| Km | 1246.35 | 1246.35 | 0.1 | False | None | None | False | None | False | 124.635 | 0 | 3254731 | 112747 | None | UNI CSR2021-22 Bescoms Vol-6 Distribution Labour | Earth work Excavation for cable trench of 0.5m to 0.75 mtr width and Depth upto 1 Mtrs including trial pits, depositing on bank upto a lead of 50 Mtrs , Supplying and Displaying necessary Danger Boards and Lighting , Using sight Rails and Sign Boards at every 100 Mtrs wherever necessary as directed. In soil (Ordinary) (1x60x0.50x0.75 = 22.50 CMT)
| cm | 273.0 | 273.0 | 22.5 | False | None | None | False | None | False | 6142.5 | 0 | 3254732 | 112747 | None | UNI CSR 2021-22 Bescoms Vol-6 Distribution Labour | Providing and filling sand in excavated trench to cover already laid UG cable to a depth of 150mm all-round the cable. (1x60x0.50x0.75 = 22.50 CMT)
| cm | 60.9 | 60.9 | 22.5 | False | None | None | False | None | False | 1370.25 | 0 | 3254733 | 112747 | None | UNI CSR 2023-24 PWD Vol-6 Elec Uti Part-III It No | Supplying and fixing Trivector Meter suitable for operation LT operation and -CT operated meter in polycarbonate body in class 0.5 accuracy as per IS 14697 and completely wired.
| Each | 4609.5 | 4609.5 | 1.0 | False | None | None | False | None | False | 4609.5 | 0 | 3254734 | 112747 | None | UNI CSR 2023-24 PWD Vol-6 Elec Uti Part-III It No | Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc. using 40mm dia 2.9mm thick 2.5 mtr long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode. The funnel should be enclosed in a CC chamber of 400x400x400mm with a cast iron cover. The earth electrode shall have staggered holes of 12mm dia and the electrode should be covered 150mm all-round with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts.
| Each | 3685.5 | 3685.5 | 2.0 | False | None | None | False | None | False | 7371.0 | 0 |
|
|
---|