createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1718973845217
version2
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee5000.00
emd915000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose19-07-2024 16:00:00
tenderQueryClose18-07-2024 16:00:00
technicalBidOpen20-07-2024 16:30:00
publishedDate21-06-2024 18:36:25
publishedByPostBBMP_EE_BTM_SOUTH
publishedByUserKPE11794 - ASHOK S BIRADAR
bidValidityPeriod90
noOfCalls1
preBidMeetingDate01-07-2024 15:00:00
preBidMeetingYnTrue
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonAshok S Biradar
splitEmdRequiredYnTrue
emdBankGuarantee815000.00
emdCash100000.00
bgValidityPeriod90
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedNone
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumberNone
mobileNumber9008658224
tenderSupplierListNone
tenderSchedule
createdTs1718973845247
version4
createdDateNone
modifiedDateNone
tenderNumberBBMP/2024-25/OW/WORK_INDENT3317
titleImprovements to BBMP office Building in Koramangala ward No. 151 Construction of Additional floors to School Building in Lakkasandra ward No. 146 and BBMP office Building in Madiwala ward No. 172 in BTM Layout Constituency (Package 02 Comprising of 4 works)
descriptionImprovements to BBMP office Building in Koramangala ward No. 151 Construction of Additional floors to School Building in Lakkasandra ward No. 146 and BBMP office Building in Madiwala ward No. 172 in BTM Layout Constituency (Package 02 Comprising of 4 works)
categoryWORKS
categoryTextWorks
ecv57064285.08
deptNameBruhat Bengaluru Mahanagara Palike
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnFalse
location890
locationNameBBMP BTM South
provisionalAmount61000000.0
groupOverheadTotalNone
fileNumberEE/BTM/AE/T-02/I-02/2024-25
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17189738450000NoneNoneOther WorksImprovements to BBMP office Building in Koramangala ward No. 151 Construction of Additional floors to School Building in Lakkasandra ward No. 146 and BBMP office Building in Madiwala ward No. 172 in BTM Layout Constituency (Package 02 Comprising of 4 works)57064285.08
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3330801116730Nonecode01Dismantling chain link fencing including removing the posts, cement concrete fedestals, foundation and stacking the useful materials safely at a distance to the appropriate disposal area as per direction of Engineer in-charge. complete as per specification and Directions of Engineer In Charge of the workKgs28.5528.55171.19FalseNoneNoneFalseNoneFalse4887.47450
3330802116730Nonecode02Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead Dismantling Stone Masonry By Manual means Rubble stone masonry in cement mortar. complete as per specification and Directions of Engineer In Charge of the workCum2185.832185.838.22FalseNoneNoneFalseNoneFalse17967.52260
3330803116730Nonecode03Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) Ground Floorcomplete as per specification and as per the directions of Engineer In Charge of the work Available Stones complete as per specification and Directions of Engineer In Charge of the workCum6557.316557.315.76FalseNoneNoneFalseNoneFalse37770.10560
3330804116730Nonecode04Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) complete as per specification and Directions of Engineer In Charge of the workCum8292.928292.9257.67FalseNoneNoneFalseNoneFalse478252.69640
3330805116730Nonecode05Providing Flush/ Ruled pointing: Pointing on stone work with cement mortar 1:3 (1 cement : 3 fine sand) after raking joints to depth nicely lining, including cost of materials, labour, curing as per specifications and as per directions of Engineer-in-charge. complete as per specification and Directions of Engineer In Charge of the workSqm330.99330.9945.96FalseNoneNoneFalseNoneFalse15212.30040
3330806116730Nonecode06Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:2:4 Using 20 mm nominal size graded crushed coarse aggregates Ground Floor complete as per specification and Directions of Engineer In Charge of the workCum8103.418103.4162.81FalseNoneNoneFalseNoneFalse508975.18210
3330807116730Nonecode07Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:2:4 Using 20 mm nominal size graded crushed coarse aggregates Third Floor complete as per specification and Directions of Engineer In Charge of the workCum8346.528346.5281.97FalseNoneNoneFalseNoneFalse684164.24440
3330808116730Nonecode08Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge complete as per specification and Directions of Engineer In Charge of the workKgs176.53176.534863.45FalseNoneNoneFalseNoneFalse858544.82850
3330809116730Nonecode09Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver/grader in sub-base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density. complete as per specification and Directions of Engineer In Charge of the workCum3321.583321.5866.61FalseNoneNoneFalseNoneFalse221250.44380
3330810116730Nonecode10Providing and laying 60mm thick factory made precast M -30 grade Cement Concrete Paver Block as per IRC SP 63:2018 & IS 15658 for Cycle Tracks & Pedestrian Footpaths of approved shape and colour, laid in required pattern and including over 30mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-incharge. (WMM/WBM Base to be paid separately if necessary as per relevant technical specification) complete as per specification and Directions of Engineer In Charge of the workSqm1386.261386.26117.07FalseNoneNoneFalseNoneFalse162289.45820
3330811116730Nonecode11Providing and fixing pre cast solid cement concrete kerb stones made out of CC 1:2:4 with top and bottom width 114 and 165 mm respectively, 400mm high and 450mm in length finished with CM 1:3 plastering and finishing cutting including formwork, curing, including cost of materials, labour charges of machinery, loading and unloading, lead and lift, transportation ete.,complete complete as per specification and Directions of Engineer In Charge of the workNos676.26676.26100.0FalseNoneNoneFalseNoneFalse67626.00
3330812116730Nonecode12Painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfaces complete as per specification and Directions of Engineer In Charge of the workSqm141.48141.4815.75FalseNoneNoneFalseNoneFalse2228.310
3330813116730Nonecode13Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work In all kinds of soils Depth upto 1.5 m complete as per specification and Directions of Engineer In Charge of the workCum314.12314.1238.88FalseNoneNoneFalseNoneFalse12212.98560
3330814116730Nonecode14Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates complete as per specification and Directions of Engineer In Charge of the workCum7773.727773.723.89FalseNoneNoneFalseNoneFalse30239.77080
3330815116730Nonecode15Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates complete as per specification and Directions of Engineer In Charge of the workCum8813.378813.3710.98FalseNoneNoneFalseNoneFalse96770.80260
3330816116730Nonecode16Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification Buildings complete as per specification and Directions of Engineer In Charge of the workTonne116115.19116115.194.35FalseNoneNoneFalseNoneFalse505101.07650
3330817116730Nonecode17Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge complete as per specification and Directions of Engineer In Charge of the workKg176.53176.5310765.2FalseNoneNoneFalseNoneFalse1900380.7560
3330818116730Nonecode18Providing,fabricating and fixing Profiled Poly Urethane insulated Roof(PUF Sheet) having modular density 40kg/m2 and size 1.06m width and 7.60m length sheets roof having external sheet of 0.5mm steel, bottom sheet of 0.40mm steel with powder coated finish. The precoated sheet shall be of minimum 240MPa steel conforming to IS 14246 : 1995 and shal have zinc coating with minimum 120gsm as per IS 277:1992,.The roofing system shall have suitable water proof over lapping arrangments and GRIHA ceritifed.The fasting shall be of self tapping screws of required length with PVC head along with washer pre-painted aluminium cap unit with build in seal arrangments. The entire roof shall be firmly fastened to the existng frame including all lead and lifts, loading & unloading ,usage charges of machinery and equipments, transportation charges, labour charges and all other incidental charges etc.,complete as per standard technical detailed specifications and as directed by the Engineer in charge of the work 50mm thickness complete as per specification and Directions of Engineer In Charge of the workSqm3368.313368.31362.02FalseNoneNoneFalseNoneFalse1219395.58620
3330819116730Nonecode19Design supply & installation of suspended Spider Glazing system designed to withstand the wind pressure as per IS 875 (Part-III). The Suspended System held with Spider Fittings of SS-316 Grade Steel of approved manufacturer with glass panel having 12 mm thick clear toughened glass held together with SS- 316 Grade Stainless steel Spider & bolt assembly with laminated glass fins 21 mm thick. The Glass fins and glass panel assembly shall be connected to Slab/beams by means of SS- 316 Grade stainless steel brackets & Anchor bolts and at the bottom using SS channel of 50x25x2mm using fastener & anchor bolts, non staining weather sealants of approved make, Teflon/ nylon bushes and separators to prevent bi-metallic contacts, all complete to perform as per specification and approved drawings. The complete system to be designed to accommodate thermal expansion & seismic movements etc. The joints between glass panels (6 to 8 mm) and gaps at the perimeter & in U channel of the assembly to be filled with non staining weather sealant, so as to make the entire system fully water proof & dust proof. The rate shall include all design, Engineering and shop drawing including approval from structural designer, labour, T&P, scaffolding, other incidental charges including wastage, enabling temporary services all fitting fixers nut bolts, washer, Buffer plates, fastener, anchors, SS channel laminated glass etc. all complete. For the purpose of payment, actual elevation area of Glazing including thickness of joints and the portion of Glass panel inside the SS channel shall be measured complete as per specification and Directions of Engineer In Charge of the workSqm10321.710321.725.92FalseNoneNoneFalseNoneFalse267538.4640
3330820116730Nonecode20Providing & Fixing of FunderMax Max Exterior panels of 4mm thick duromete hugh pressure laminates (HPL) in accordance with EN 438-6 Type EDF produced in lamination presses under freat pressure and high temperature. Double hardened acrylic, PUR resins which provide extremely effective weather protection particularly suitable for long asting balconies and facade cladding with all lead and lift and loading and unloading as per the direction of In Charge of the work complete as per specification and Directions of Engineer In Charge of the workSqm9440.09440.0433.14FalseNoneNoneFalseNoneFalse4088841.60
3330821116730Nonecode21Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For Fixed Portion :Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron) including cost of materials, labour, usage charges of machinery complete as per specifications complete as per specification and Directions of Engineer In Charge of the workKgs647.7647.748.0FalseNoneNoneFalseNoneFalse31089.60
3330822116730Nonecode22Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer- in-charge: Pre-laminated particle board with decorative lamination on both sides including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. complete as per specification and Directions of Engineer In Charge of the workSqm1275.931275.9386.94FalseNoneNoneFalseNoneFalse110929.35420
3330823116730Nonecode23Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness (weight not less than 10kg/ m²) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. complete as per specification and Directions of Engineer In Charge of the workSqm1282.421282.4257.96FalseNoneNoneFalseNoneFalse74329.06320
3330824116730Nonecode24Demolishing cement concrete manually/ by mechanical means including disposal of material to the appropriate disposal area as per direction of Engineer-in-charge. complete as per specification and Directions of Engineer In Charge of the workCum2158.572158.5714.67FalseNoneNoneFalseNoneFalse31666.22190
3330825116730Nonecode25Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge. In cement mortar complete as per specification and Directions of Engineer In Charge of the workCum1335.641335.6424.06FalseNoneNoneFalseNoneFalse32135.49840
3330826116730Nonecode26Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work -as per direction of Engineer-in-charge. for all kinds of soil depth up to 3m complete as per specification and Directions of Engineer In Charge of the workCum132.4132.49.41FalseNoneNoneFalseNoneFalse1245.8840
3330827116730Nonecode27Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates complete as per specification and Directions of Engineer In Charge of the workCum9252.149252.149.84FalseNoneNoneFalseNoneFalse91041.05760
3330828116730Nonecode28Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates complete as per specification and Directions of Engineer In Charge of the workCum14211.5414211.545.59FalseNoneNoneFalseNoneFalse79442.50860
3330829116730Nonecode29Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates complete as per specification and Directions of Engineer In Charge of the workCum13323.3213323.3210.2FalseNoneNoneFalseNoneFalse135897.8640
3330830116730Nonecode30Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. (Page No. 17, Item No.6.32 of PWD Bengaluru Circle SR 2021-22-Vol-2) ---- the item is inclusive of all materials, lead and lift ,loading and unloading, Transportation charges and other incidental charges and work should be carried out as per the directions of the Engineer-in-charge of the work. complete as per specification and Directions of Engineer In Charge of the workSqm1700.381700.38338.1FalseNoneNoneFalseNoneFalse574898.4780
3330831116730Nonecode31Providing & fixing of 2-track x 2-panel sliding windows made out of multi chambered UPVC (Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 50mm width x 42mmheight with reinforcement of 1mm thickness and Sash with overall size of 31mm X 57mm with Gi reinforcement of 1mm for the frame and 1.5 mm for the sash. Coextruded Glazing bead for fixing of glass shall be of size 21.5mm x 9.5 mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. (Page No. 110, Item No.12.86 of PWD Bengaluru Circle SR 2021-22 - Vol-2) ---- the item is inclusive of all materials, lead and lift ,loading and unloading, Transportation charges and other incidental charges and work should be carried out as per the directions of the Engineer-in-charge of the work. complete as per specification and Directions of Engineer In Charge of the workSqm6996.226996.2247.94FalseNoneNoneFalseNoneFalse335398.78680
3330832116730Nonecode32Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. complete as per specification and Directions of Engineer In Charge of the workSqm6915.746915.74466.64FalseNoneNoneFalseNoneFalse3227160.91360
3330833116730Nonecode33Providing and fixing of wall cladding using 20mm thick gang saw water cut Shiva gold granite, grey granite in CM 1:3 (1 cement : 3 coarse sand) proportion cut to required shape, pattern with paper joints, finished with cement mortal using white cement and colour pigments to match the colour of slab making through jointing with sealant, making holes 25mmx12mm grooves in joints including cost of all materials, mortar, labour, curing etc., complete. complete as per specification and Directions of Engineer In Charge of the workSqm4359.984359.98175.44FalseNoneNoneFalseNoneFalse764914.89120
3330834116730Nonecode34Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts,bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. Ground Floor complete as per specification and Directions of Engineer In Charge of the workKgs733.37733.37335.04FalseNoneNoneFalseNoneFalse245708.28480
3330835116730Nonecode35Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (Including Centering and Shuttering for Lintel, Beams) First Floor complete as per specification and Directions of Engineer In Charge of the workCum14353.6614353.661.22FalseNoneNoneFalseNoneFalse17511.46520
3330836116730Nonecode36Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (Including Centering and Shuttering for Slab) First Floor complete as per specification and Directions of Engineer In Charge of the workCum13456.5513456.552.84FalseNoneNoneFalseNoneFalse38216.6020
3330837116730Nonecode37Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification Buildings First Floor complete as per specification and Directions of Engineer In Charge of the workTonne117276.34117276.340.44FalseNoneNoneFalseNoneFalse51601.58960
3330838116730Nonecode38Providing and laying autoclaved aerated cement blocks masonry with 150mm/230mm/300 mm thick AAC blocks as per IS 2185 (Part III) in super structure above plinth level up to floor I level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. First Floor complete as per specification and Directions of Engineer In Charge of the workCum10458.110458.14.18FalseNoneNoneFalseNoneFalse43714.8580
3330839116730Nonecode39Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge First Floor complete as per specification and Directions of Engineer In Charge of the workSqm386.74386.7448.55FalseNoneNoneFalseNoneFalse18776.2270
3330840116730Nonecode40Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. First Floor complete as per specification and Directions of Engineer In Charge of the workSqm116.68116.68117.38FalseNoneNoneFalseNoneFalse13695.89840
3330841116730Nonecode41Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade: One coats on old work as per specifications and as per directions of Engineer in charge. First Floor complete as per specification and Directions of Engineer In Charge of the workSqm107.5107.5230.32FalseNoneNoneFalseNoneFalse24759.40
3330842116730Nonecode42Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. First Floor complete as per specification and Directions of Engineer In Charge of the workSqm6984.96984.9494.91FalseNoneNoneFalseNoneFalse3456896.8590
3330843116730Nonecode43Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 including pointing the joints with white cement and matching pigment etc., complete First Floor complete as per specification and Directions of Engineer In Charge of the workSqm1410.611410.6130.48FalseNoneNoneFalseNoneFalse42995.39280
3330844116730Nonecode44Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. First Floor complete as per specification and Directions of Engineer In Charge of the workSqm1899.611899.6148.56FalseNoneNoneFalseNoneFalse92245.06160
3330845116730Nonecode45Providing and fixing of wall cladding using 20mm thick gang saw water cut Shiva gold granite, grey granite in CM 1:3 (1 cement : 3 coarse sand) proportion cut to required shape, pattern with paper joints, finished with cement mortal using white cement and colour pigments to match the colour of slab making through jointing with sealant, making holes 25mmx12mm grooves in joints including cost of all materials, mortar, labour, curing etc., complete. First Floor complete as per specification and Directions of Engineer In Charge of the workSqm4403.584403.58122.4FalseNoneNoneFalseNoneFalse538998.1920
3330846116730Nonecode46Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges. with both side prelam First Floor complete as per specification and Directions of Engineer In Charge of the workSqm3101.783101.783.47FalseNoneNoneFalseNoneFalse10763.17660
3330847116730Nonecode47Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc. First Floor complete as per specification and Directions of Engineer In Charge of the workKgs239.91239.912500.98FalseNoneNoneFalseNoneFalse600010.11180
3330848116730Nonecode48Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) First Floor complete as per specification and Directions of Engineer In Charge of the workSqm7497.497497.491.08FalseNoneNoneFalseNoneFalse8097.28920
3330849116730Nonecode49Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts,bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. First Floor complete as per specification and Directions of Engineer In Charge of the workKgs740.7740.7833.64FalseNoneNoneFalseNoneFalse617477.1480
3330850116730Nonecode50Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (Including Centering and Shuttering for Columns) Second Floor complete as per specification and Directions of Engineer In Charge of the workCum15401.7615401.762.92FalseNoneNoneFalseNoneFalse44973.13920
3330851116730Nonecode51Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (Including Centering and Shuttering for Lintel, Beams) Second Floor complete as per specification and Directions of Engineer In Charge of the workCum14495.7714495.776.64FalseNoneNoneFalseNoneFalse96251.91280
3330852116730Nonecode52Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (Including Centering and Shuttering for Slab) Second Floor complete as per specification and Directions of Engineer In Charge of the workCum13589.7913589.7915.98FalseNoneNoneFalseNoneFalse217164.84420
3330853116730Nonecode53Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification Buildings Second Floor complete as per specification and Directions of Engineer In Charge of the workTonne118437.49118437.4915.18FalseNoneNoneFalseNoneFalse1797881.09820
3330854116730Nonecode54Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. Second Floor complete as per specification and Directions of Engineer In Charge of the workSqm1734.391734.39482.18FalseNoneNoneFalseNoneFalse836288.17020
3330855116730Nonecode55Providing and laying autoclaved aerated cement blocks masonry with 150mm/230mm/300 mm thick AAC blocks as per IS 2185 (Part III) in super structure above plinth level up to floor I level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. Second Floor complete as per specification and Directions of Engineer In Charge of the workCum10562.5510562.554.18FalseNoneNoneFalseNoneFalse44151.4590
3330856116730Nonecode56Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Second Floor complete as per specification and Directions of Engineer In Charge of the workSqm337.61337.61230.32FalseNoneNoneFalseNoneFalse77758.33520
3330857116730Nonecode57Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge Second Floor complete as per specification and Directions of Engineer In Charge of the workSqm390.57390.5755.46FalseNoneNoneFalseNoneFalse21661.01220
3330858116730Nonecode58Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Second Floor complete as per specification and Directions of Engineer In Charge of the workSqm468.67468.67117.38FalseNoneNoneFalseNoneFalse55012.48460
3330859116730Nonecode59Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Second Floor complete as per specification and Directions of Engineer In Charge of the workSqm117.83117.83117.38FalseNoneNoneFalseNoneFalse13830.88540
3330860116730Nonecode60Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade: One coats on old work as per specifications and as per directions of Engineer in charge. Second Floor complete as per specification and Directions of Engineer In Charge of the workSqm108.56108.56230.32FalseNoneNoneFalseNoneFalse25003.53920
3330861116730Nonecode61Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. Second Floor complete as per specification and Directions of Engineer In Charge of the workSqm7054.067054.06530.88FalseNoneNoneFalseNoneFalse3744859.37280
3330862116730Nonecode62Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 including pointing the joints with white cement and matching pigment etc., complete Second Floor complete as per specification and Directions of Engineer In Charge of the workSqm1424.581424.5830.48FalseNoneNoneFalseNoneFalse43421.19840
3330863116730Nonecode63Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. Second Floor complete as per specification and Directions of Engineer In Charge of the workSqm1918.421918.4255.46FalseNoneNoneFalseNoneFalse106395.57320
3330864116730Nonecode64Providing and fixing of wall cladding using 20mm thick gang saw water cut Shiva gold granite, grey granite in CM 1:3 (1 cement : 3 coarse sand) proportion cut to required shape, pattern with paper joints, finished with cement mortal using white cement and colour pigments to match the colour of slab making through jointing with sealant, making holes 25mmx12mm grooves in joints including cost of all materials, mortar, labour, curing etc., complete. Second Floor complete as per specification and Directions of Engineer In Charge of the workSqm4447.184447.18187.8FalseNoneNoneFalseNoneFalse835180.4040
3330865116730Nonecode65Providing Honne wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications Second Floor complete as per specification and Directions of Engineer In Charge of the workCum182804.45182804.450.29FalseNoneNoneFalseNoneFalse53013.29050
3330866116730Nonecode66Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. Second Floor complete as per specification and Directions of Engineer In Charge of the workNos1345.141345.147.0FalseNoneNoneFalseNoneFalse9415.980
3330867116730Nonecode67Providing and fixing in position fully panelled Honne wood shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. ( excluding cost of fixtures ) Second Floor complete as per specification and Directions of Engineer In Charge of the workSqm9855.569855.565.4FalseNoneNoneFalseNoneFalse53220.0240
3330868116730Nonecode68Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges. with both side prelam Second Floor complete as per specification and Directions of Engineer In Charge of the workSqm3132.493132.493.47FalseNoneNoneFalseNoneFalse10869.74030
3330869116730Nonecode69Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc. Second Floor complete as per specification and Directions of Engineer In Charge of the workKgs242.28242.283989.16FalseNoneNoneFalseNoneFalse966493.68480
3330870116730Nonecode70Providing & fixing of 2.5 track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 81mm width x 42mmheight with reinforcement of 1mm thickness and Sash with overall size of 31mm x 57mm and mesh sash of size with GI reinforcement of 1.5mm thickness. Coextruded Glazing bead for fixing of glass shall be of size 21.5mm x 9.5mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 1.8-2.0mm. Maximum possible size 1519mm x 1519mm (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) Second Floor complete as per specification and Directions of Engineer In Charge of the workSqm8673.268673.26102.18FalseNoneNoneFalseNoneFalse886233.70680
3330871116730Nonecode71Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) Second Floor complete as per specification and Directions of Engineer In Charge of the workSqm7571.737571.731.08FalseNoneNoneFalseNoneFalse8177.46840
3330872116730Nonecode72Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts,bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. Second Floor complete as per specification and Directions of Engineer In Charge of the workKgs748.04748.04833.64FalseNoneNoneFalseNoneFalse623596.06560
3330873116730Nonecode73Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (Including Centering and Shuttering for Columns) Third Floor complete as per specification and Directions of Engineer In Charge of the workCum15552.7615552.762.92FalseNoneNoneFalseNoneFalse45414.05920
3330874116730Nonecode74Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (Including Centering and Shuttering for Lintel, Beams) Third Floor complete as per specification and Directions of Engineer In Charge of the workCum14637.8914637.892.03FalseNoneNoneFalseNoneFalse29714.91670
3330875116730Nonecode75Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (Including Centering and Shuttering for Slab) Third Floor complete as per specification and Directions of Engineer In Charge of the workCum13723.0213723.022.52FalseNoneNoneFalseNoneFalse34582.01040
3330876116730Nonecode76Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification Buildings Third Floor complete as per specification and Directions of Engineer In Charge of the workTonne119598.64119598.6412.57FalseNoneNoneFalseNoneFalse1503354.90480
3330877116730Nonecode77Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. Third Floor complete as per specification and Directions of Engineer In Charge of the workSqm1751.391751.39421.59FalseNoneNoneFalseNoneFalse738368.51010
3330878116730Nonecode78Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Third Floor complete as per specification and Directions of Engineer In Charge of the workSqm340.92340.9267.22FalseNoneNoneFalseNoneFalse22916.64240
3330879116730Nonecode79Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Third Floor complete as per specification and Directions of Engineer In Charge of the workSqm473.28473.2859.54FalseNoneNoneFalseNoneFalse28179.09120
3330880116730Nonecode80Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Third Floor complete as per specification and Directions of Engineer In Charge of the workSqm118.99118.9959.54FalseNoneNoneFalseNoneFalse7084.66460
3330881116730Nonecode81Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade: One coats on old work as per specifications and as per directions of Engineer in charge. Third Floor complete as per specification and Directions of Engineer In Charge of the workSqm109.63109.6367.22FalseNoneNoneFalseNoneFalse7369.32860
3330882116730Nonecode82Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges. with both side prelam Third Floor complete as per specification and Directions of Engineer In Charge of the workSqm3163.23163.22.21FalseNoneNoneFalseNoneFalse6990.6720
3330883116730Nonecode83Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. Third Floor complete as per specification and Directions of Engineer In Charge of the workSqm7123.227123.22438.36FalseNoneNoneFalseNoneFalse3122534.71920
3330884116730Nonecode84Providing and fixing of wall cladding using 20mm thick gang saw water cut Shiva gold granite, grey granite in CM 1:3 (1 cement : 3 coarse sand) proportion cut to required shape, pattern with paper joints, finished with cement mortal using white cement and colour pigments to match the colour of slab making through jointing with sealant, making holes 25mmx12mm grooves in joints including cost of all materials, mortar, labour, curing etc., complete. Third Floor complete as per specification and Directions of Engineer In Charge of the workSqm4490.784490.7850.4FalseNoneNoneFalseNoneFalse226335.3120
3330885116730Nonecode85Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. Third Floor complete as per specification and Directions of Engineer In Charge of the workKgs755.37755.37359.4FalseNoneNoneFalseNoneFalse271479.9780
3330886116730Nonecode86Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for Columns Second Floor complete as per specification and Directions of Engineer In Charge of the workCum14922.3514922.3513.09FalseNoneNoneFalseNoneFalse195333.56150
3330887116730Nonecode87Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for Lintel and Beams Second Floor complete as per specification and Directions of Engineer In Charge of the workCum14044.5714044.5728.02FalseNoneNoneFalseNoneFalse393528.85140
3330888116730Nonecode88Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for Slab and Staircase Second Floor complete as per specification and Directions of Engineer In Charge of the workCum13166.7813166.7852.47FalseNoneNoneFalseNoneFalse690860.94660
3330889116730Nonecode89Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates For Chajjas Second Floor complete as per specification and Directions of Engineer In Charge of the workCum12727.8912727.891.04FalseNoneNoneFalseNoneFalse13237.00560
3330890116730Nonecode90Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. For Columns Third Floor complete as per specification and Directions of Engineer In Charge of the workCum15068.6515068.6513.09FalseNoneNoneFalseNoneFalse197248.62850
3330891116730Nonecode91Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. for Lintel and Beams Third Floor complete as per specification and Directions of Engineer In Charge of the workCum14182.2614182.2628.02FalseNoneNoneFalseNoneFalse397386.92520
3330892116730Nonecode92Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. For Slabs and Staircase Third Floor complete as per specification and Directions of Engineer In Charge of the workCum13295.8713295.8752.47FalseNoneNoneFalseNoneFalse697634.29890
3330893116730Nonecode93Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. For Chajjas Third Floor complete as per specification and Directions of Engineer In Charge of the workCum12852.6712852.671.04FalseNoneNoneFalseNoneFalse13366.77680
3330894116730Nonecode94Providing and laying Vitrified tiles with thickness 9-10 mm in floor with different sizes with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). Size of Tile 600x600 mm Second Floor complete as per specification and Directions of Engineer In Charge of the workSqm1639.061639.06214.88FalseNoneNoneFalseNoneFalse352201.21280
3330895116730Nonecode95Providing and laying Vitrified tiles with thickness 9-10 mm in floor with different sizes with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). Size of Tile 600x600 mm Third Floor complete as per specification and Directions of Engineer In Charge of the workSqm1655.131655.13214.88FalseNoneNoneFalseNoneFalse355654.33440
3330896116730Nonecode96Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 including pointing the joints with white cement and matching pigment etc., complete Ground Floor complete as per specification and Directions of Engineer In Charge of the workSqm1396.651396.6524.0FalseNoneNoneFalseNoneFalse33519.60
3330897116730Nonecode97Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Second Floor complete as per specification and Directions of Engineer In Charge of the workSqm462.06462.0655.6FalseNoneNoneFalseNoneFalse25690.5360
3330898116730Nonecode98Providing skirting, dadooing, rises of steps with white glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. Ground Floor complete as per specification and Directions of Engineer In Charge of the workSqm1806.821806.8255.6FalseNoneNoneFalseNoneFalse100459.1920
3330899116730Nonecode99Providing skirting, dadooing, rises of steps with white glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. First Floor complete as per specification and Directions of Engineer In Charge of the workSqm1824.881824.8855.6FalseNoneNoneFalseNoneFalse101463.3280
3330900116730Nonecode100Providing skirting, dadooing, rises of steps with white glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. Second Floor complete as per specification and Directions of Engineer In Charge of the workSqm1842.951842.9555.6FalseNoneNoneFalseNoneFalse102468.020
3330901116730Nonecode101Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross- section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame Ground Floor complete as per specification and Directions of Engineer In Charge of the workm834.61834.6136.9FalseNoneNoneFalseNoneFalse30797.1090
3330902116730Nonecode102Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross- section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminate shall be moulded with fire resistant grade unsaturatedpolyester resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame First Floor complete as per specification and Directions of Engineer In Charge of the workm842.96842.9636.9FalseNoneNoneFalseNoneFalse31105.2240
3330903116730Nonecode103Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross- section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame Second Floor complete as per specification and Directions of Engineer In Charge of the workm851.3851.336.9FalseNoneNoneFalseNoneFalse31412.970
3330904116730Nonecode104Providing and fixing to existing door frames Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames.30 mm thickness Ground FLoor complete as per specification and Directions of Engineer In Charge of the workSqm4158.794158.797.98FalseNoneNoneFalseNoneFalse33187.14420
3330905116730Nonecode105Providing and fixing to existing door frames Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames.30 mm thickness First Floor complete as per specification and Directions of Engineer In Charge of the workSqm4200.384200.387.98FalseNoneNoneFalseNoneFalse33519.03240
3330906116730Nonecode106Providing and fixing to existing door frames Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames.30 mm thickness Second Floor complete as per specification and Directions of Engineer In Charge of the workSqm4241.974241.977.98FalseNoneNoneFalseNoneFalse33850.92060
3330907116730Nonecode107Providing and laying Black Lapotra Granite stone flooring in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge Ground Floor complete as per specification and Directions of Engineer In Charge of the workSqm3351.443351.44127.77FalseNoneNoneFalseNoneFalse428213.48880
3330908116730Nonecode108Providing and laying Black Lapotra Granite stone flooring in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge First Floor complete as per specification and Directions of Engineer In Charge of the workSqm3384.953384.95127.77FalseNoneNoneFalseNoneFalse432495.06150
3330909116730Nonecode109Providing and laying Black Lapotra Granite stone flooring in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge Second Floor complete as per specification and Directions of Engineer In Charge of the workSqm3418.463418.46127.77FalseNoneNoneFalseNoneFalse436776.63420
3330910116730Nonecode110Providing and laying Black Lapotra Granite stone flooring in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge Third Floor complete as per specification and Directions of Engineer In Charge of the workSqm3451.983451.98122.67FalseNoneNoneFalseNoneFalse423454.38660
3330911116730Nonecode111Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Second Floor complete as per specification and Directions of Engineer In Charge of the workSqm390.57390.57927.47FalseNoneNoneFalseNoneFalse362241.95790
3330912116730Nonecode112Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Third Floor complete as per specification and Directions of Engineer In Charge of the workSqm394.4394.4866.07FalseNoneNoneFalseNoneFalse341578.0080
3330913116730Nonecode113Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Second Floor complete as per specification and Directions of Engineer In Charge of the workSqm509.72509.72259.94FalseNoneNoneFalseNoneFalse132496.61680
3330914116730Nonecode114Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removingscaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Third Floor complete as per specification and Directions of Engineer In Charge of the workSqm514.72514.72498.0FalseNoneNoneFalseNoneFalse256330.560
3330915116730Nonecode115Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. Second Floor complete as per specification and Directions of Engineer In Charge of the workSqm132.4132.4902.13FalseNoneNoneFalseNoneFalse119442.0120
3330916116730Nonecode116Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. Third Floor complete as per specification and Directions of Engineer In Charge of the workSqm133.69133.69866.06FalseNoneNoneFalseNoneFalse115783.56140
3330917116730Nonecode117Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :Water thinnable cement primer to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labourcomplete as per specifications and as per directions of Engineer-in-charge. Second Floor complete as per specification and Directions of Engineer In Charge of the workSqm70.1770.17902.13FalseNoneNoneFalseNoneFalse63302.46210
3330918116730Nonecode118Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :Water thinnable cement primer to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Third Floor complete as per specification and Directions of Engineer In Charge of the workSqm70.8670.86840.73FalseNoneNoneFalseNoneFalse59574.12780
3330919116730Nonecode119Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 g/L and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 L/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Second Floor complete as per specification and Directions of Engineer In Charge of the workSqm206.54206.54902.13FalseNoneNoneFalseNoneFalse186325.93020
3330920116730Nonecode120Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 g/L and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 L/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Third Floor complete as per specification and Directions of Engineer In Charge of the workSqm208.56208.56898.76FalseNoneNoneFalseNoneFalse187445.38560
3330921116730Nonecode121Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc. Ground Floor complete as per specification and Directions of Engineer In Charge of the workKgs237.53237.532478.3FalseNoneNoneFalseNoneFalse588670.5990
3330922116730Nonecode122Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc. Third Floor complete as per specification and Directions of Engineer In Charge of the workKgs244.66244.663854.16FalseNoneNoneFalseNoneFalse942958.78560
3330923116730Nonecode123Providing & fixing of 2.5 track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 81mm width x 42mmheight with reinforcement of 1mm thickness and Sash with overall size of 31mm x 57mm and mesh sash of size with GI reinforcement of 1.5mm thickness. Coextruded Glazing bead for fixing of glass shall be of size 21.5mm x 9.5mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 1.8-2.0mm. Maximum possible size 1519mm x 1519mm (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) Ground Floor complete as per specification and Directions of Engineer In Charge of the workSqm8503.28503.242.0FalseNoneNoneFalseNoneFalse357134.40
3330924116730Nonecode124Providing & fixing of 2.5 track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 81mm width x 42mmheight with reinforcement of 1mm thickness and Sash with overall size of 31mm x 57mm and mesh sash of size with GI reinforcement of 1.5mm thickness. Coextruded Glazing bead for fixing of glass shall be of size 21.5mm x 9.5mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 1.8-2.0mm. Maximum possible size 1519mm x 1519mm (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) First Floor complete as per specification and Directions of Engineer In Charge of the workSqm8588.238588.2342.0FalseNoneNoneFalseNoneFalse360705.660
3330925116730Nonecode125Providing & fixing of 2.5 track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 81mm width x 42mmheight with reinforcement of 1mm thickness and Sash with overall size of 31mm x 57mm and mesh sash of size with GI reinforcement of 1.5mm thickness. Coextruded Glazing bead for fixing of glass shall be of size 21.5mm x 9.5mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 1.8-2.0mm. Maximum possible size 1519mm x 1519mm (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) Third Floor complete as per specification and Directions of Engineer In Charge of the workSqm8758.298758.2944.85FalseNoneNoneFalseNoneFalse392809.30650
3330926116730Nonecode126Providing Honne wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. Second Floor complete as per specification and Directions of Engineer In Charge of the workCum182804.45182804.450.33FalseNoneNoneFalseNoneFalse60325.46850
3330927116730Nonecode127Providing Honne wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. Third Floor complete as per specification and Directions of Engineer In Charge of the workCum184596.65184596.650.41FalseNoneNoneFalseNoneFalse75684.62650
3330928116730Nonecode128Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. Third Floor complete as per specification and Directions of Engineer In Charge of the workNo1358.331358.335.0FalseNoneNoneFalseNoneFalse6791.650
3330929116730Nonecode129Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. - 35 mm thick both side Teak Second Floor complete as per specification and Directions of Engineer In Charge of the workSqm6000.196000.1914.4FalseNoneNoneFalseNoneFalse86402.7360
3330930116730Nonecode130Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. - 35 mm thick both side Teak Third Floor complete as per specification and Directions of Engineer In Charge of the workSqm4017.54017.518.0FalseNoneNoneFalseNoneFalse72315.00
3330931116730Nonecode131Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. Second Floor complete as per specification and Directions of Engineer In Charge of the workSqm1461.651461.6541.01FalseNoneNoneFalseNoneFalse59942.26650
3330932116730Nonecode132Providing and fixing Veneer Panelling over the aluminium frame work covered with 4mm Veneer fixed over 19mm Ply complete including cost and conveyonce of all materials, labour for all item of work HOM of equipments etc complete as per specification complete as per specification and Directions of Engineer In Charge of the workSqm8791.08791.066.72FalseNoneNoneFalseNoneFalse586535.520
3330933116730Nonecode133Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge. complete as per specification and Directions of Engineer In Charge of the workSqm1060.471060.47916.16FalseNoneNoneFalseNoneFalse971560.19520
3330934116730Nonecode134Geophysical investigation at site for sinking borewells for supplying drinking water to the habitation either through the Hand Pump MWS or P.W.S.S, by vertical electrical sounding by adopting Venner or Schlumbergers’s method, including reconnaissance survey of geological formation. Geophysical investigation of existing ground water in the vicinity, its quality, quantity and acceptability of the users, indicating the location of the site, recommended depth of casing pipe required to seal the top unconsolidated formation including an extra depth of 1.0 metre in consolidated formation for proper seating of casing pipe, depth of drilling required to cover full depth of aquifer proposed to be tapped, probable yield and other information required including transportation of instruments and accessories to work site, engaging technical personal and labour required etc. NOTE: 1) Additional rate on item 1&2 is allowed for drilling in over burden and fixing Casing pipes beyond 20 M (for fixing Casing pipes only) a) Above 20 M and upto 30 M - 15%, b) Above 30 M - 30% (Measurement of overburden is restricted to the depth of casing pipe fixed excluding initial depth of 20M and projection above ground level). 2) A sum of Rs. 100/- is to be deducted for Dry Borewell towards yield test. complete as per specification and Directions of Engineer In Charge of the workEach6863.826863.821.0FalseNoneNoneFalseNoneFalse6863.820
3330935116730Nonecode135Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth) Borewell depth of 0 to 50 Mtrs complete as per specification and Directions of Engineer In Charge of the workm480.26480.2650.0FalseNoneNoneFalseNoneFalse24013.00
3330936116730Nonecode136Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth) Borewell depth of 50 to 100 Mtrs complete as per specification and Directions of Engineer In Charge of the workm602.27602.2750.0FalseNoneNoneFalseNoneFalse30113.50
3330937116730Nonecode137Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth) Borewell depth of 100 to 150 Mtrs complete as per specification and Directions of Engineer In Charge of the workm639.91639.9150.0FalseNoneNoneFalseNoneFalse31995.50
3330938116730Nonecode138Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth) Borewell depth of 150 to 200 Mtrs complete as per specification and Directions of Engineer In Charge of the workm742.46742.4650.0FalseNoneNoneFalseNoneFalse37123.00
3330939116730Nonecode139Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth) Borewell depth of 200 to 250 Mtrs complete as per specification and Directions of Engineer In Charge of the workm870.96870.9650.0FalseNoneNoneFalseNoneFalse43548.00
3330940116730Nonecode140Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth) Borewell depth of 250 to 300 Mtrs complete as per specification and Directions of Engineer In Charge of the workm960.52960.5250.0FalseNoneNoneFalseNoneFalse48026.00
3330941116730Nonecode141Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth) Borewell depth of 300 to 350 Mtrs complete as per specification and Directions of Engineer In Charge of the workm1126.661126.6650.0FalseNoneNoneFalseNoneFalse56333.00
3330942116730Nonecode142Supply of ISI mark 175mm nominal bore,plain and steel casing pipe grade of steel Fe 410 of wall thickness conforming to IS 4270-2001 and latest ammendments, electrical resistance welded steel tubes, material and conforming to IS 1387-1993 and manufactured by basic open hearth electric or basic oxygen process in random length of 5-7m both ends.threaded conforming to IS 554-1985 one end fixed with socket conforming to IS 4270-2001 and the other end with screwed pipes all shall be responsibaly free from defects. The tubes shall be responsible straight end should be with ISI marking weighing 25.10kg/m.prices include Collar-Medium duty complete as per specification and Directions of Engineer In Charge of the workm2509.032509.03120.0FalseNoneNoneFalseNoneFalse301083.60
3330943116730Nonecode143Providing and laying at site of work MS casing caps as per IS 1239 (part II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments including cost of material and labour charges for fixing, if any etc. complete with all lead and lifts and as directed by the Engineer in charge complete as per specification and Directions of Engineer In Charge of the workEach212.87212.871.0FalseNoneNoneFalseNoneFalse212.870
3330944116730Nonecode144Supply and delivery of Centrifugal pumpset at site brand new best make and with discharge duty confirming to ISI standards and its latest amendments. 10 HP, size 80x65 Head 34.50M, Discharge 840 LPM complete as per specification and Directions of Engineer In Charge of the workEach48834.6548834.651.0FalseNoneNoneFalseNoneFalse48834.650
3330945116730Nonecode145Labour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all items including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges,tools and equipments etc., involved in the job as per specifications, with necessary tests as per specifications, with testing of as per instructions of engineer incharge of work. complete as per specification and Directions of Engineer In Charge of the workEach8437.08437.01.0FalseNoneNoneFalseNoneFalse8437.00
3330946116730Nonecode146Supply and delivery at site Brand new best make PVC insulated cable of Flat 3 core (sheathed) of nominal cross sectional area as per IS 694-1990 with ISI Mark and as per its latest amendments. 1x3x6 m2 complete as per specification and Directions of Engineer In Charge of the workm240.13240.13370.0FalseNoneNoneFalseNoneFalse88848.10
3330947116730Nonecode147Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOL Direct Online Starter 2) S-D- Star Delta Starter 6 to 15 HP pumps complete as per specification and Directions of Engineer In Charge of the workEach20638.220638.21.0FalseNoneNoneFalseNoneFalse20638.20
3330948116730Nonecode148Supply and delivery at site of brand new best make non-return valve as per IS 778/1984 with ISI Mark and as per its latest amendments Size 50 mm complete as per specification and Directions of Engineer In Charge of the workEach1622.51622.52.0FalseNoneNoneFalseNoneFalse3245.00
3330949116730Nonecode149Supply and delivery of galvanized mild steel tubes of 6mtr standard length heavy duty (C Class) as per IS 1239 (Part-I) 1990 with latest amendments with ISI Mark (one end fitted with Heavy Duty collar and other end fitted with protective cover. 50 mm complete as per specification and Directions of Engineer In Charge of the workm3958.93958.950.0FalseNoneNoneFalseNoneFalse197945.00
3330950116730Nonecode150Supply and delivery at site of brand new best make gate valve as per IS 778/1984 with ISI Mark and as per its latest amendments.Size 50 mm complete as per specification and Directions of Engineer In Charge of the workEach1622.51622.55.0FalseNoneNoneFalseNoneFalse8112.50
3330951116730Nonecode151Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work. In all kinds of soils. Depth upto 1.50m complete as per specification and Directions of Engineer In Charge of the workCum628.23628.23225.0FalseNoneNoneFalseNoneFalse141351.750
3330952116730Nonecode152Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 50 mm nominal dia Pipes complete as per specification and Directions of Engineer In Charge of the workm935.86935.86225.0FalseNoneNoneFalseNoneFalse210568.50
3330953116730Nonecode153Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.. complete as per specification and Directions of Engineer In Charge of the workEach7079.297079.2910.0FalseNoneNoneFalseNoneFalse70792.90
3330954116730Nonecode154Providing and constructing “WIRE CUT BRICK MACHINEHOLE CHAMBERS” using Portland/Pozzolana cement, conical in shape at top, with CC 1:3:6 foundation using 40mm and down size graded metal of approved quality and with an offset of 0.15M alround the chamber. Construct Brick masonry in CM 1:4, 340 mm thick, with wirecut bricks of approved quality,plaster inside and out side with CM 1:3, 12mm thick, except for the conical surface outside where the plaster thickness shall be 20mm. Slope inside to be 1:6 in the concrete towards central drain and finished smooth. Fixing of pipes in CC 1:2:4 with graded metal of 20mm and down size. Supplying and fixing SFRC Machinehole frame and cover (Heavy Duty) conforming to IS:12592 with latest amendment, in CC 1:2:4. Supplying and fixing footsteps made of 12mm dia. steel bars (Fe-500) with 3mm thick plastic encapsulation (IS-10910). The footsteps shall be fixed 30cms apart and on CC block embeded to masonry wall. The whole works include watering, curing, barricading, danger lighting, pouring tar over MH frame and cover, cost of tar, shoring, strutting, dewatering, engraving Machinehole number with flow direction on the inner conical surface etc. as per the drawing etc. as per technical specifications and for the following diameters and depth etc. for 1.2mm diaCirc. B M.H: Constructing Brick Masonry Circular Machinehole 1.2 m internal dia. 1.0 M depth & SFRC cover & frame complete as per specification and Directions of Engineer In Charge of the workEach37703.037703.05.0FalseNoneNoneFalseNoneFalse188515.00
3330955116730Nonecode155Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid complete as per specification and Directions of Engineer In Charge of the workEach7758.157758.156.0FalseNoneNoneFalseNoneFalse46548.90
3330956116730Nonecode156Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests complete as per specification and Directions of Engineer In Charge of the workEach6339.436339.436.0FalseNoneNoneFalseNoneFalse38036.580
3330957116730Nonecode157Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required: using White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer complete as per specification and Directions of Engineer In Charge of the workEach5349.065349.068.0FalseNoneNoneFalseNoneFalse42792.480
3330958116730Nonecode158Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings. complete as per specification and Directions of Engineer In Charge of the workEach1847.051847.058.0FalseNoneNoneFalseNoneFalse14776.40
3330959116730Nonecode159Providing and fixing PTMT grating of approved quality and colour. Circular type.100 mm nominal dia complete as per specification and Directions of Engineer In Charge of the workEach53.2253.2224.0FalseNoneNoneFalseNoneFalse1277.280
3330960116730Nonecode160Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Flexible pipe 40 mm dia complete as per specification and Directions of Engineer In Charge of the workEach119.42119.428.0FalseNoneNoneFalseNoneFalse955.360
3330961116730Nonecode161Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for cold water supply including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External works 40 mm nominal dia Pipes complete as per specification and Directions of Engineer In Charge of the workm394.59394.59100.0FalseNoneNoneFalseNoneFalse39459.00
3330962116730Nonecode162Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for cold water supply including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External works 50 mm nominal dia Pipes complete as per specification and Directions of Engineer In Charge of the workm501.03501.0350.0FalseNoneNoneFalseNoneFalse25051.50
3330963116730Nonecode163Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for cold water supply including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External works 80 mm nominal dia Pipes complete as per specification and Directions of Engineer In Charge of the workm874.85874.8550.0FalseNoneNoneFalseNoneFalse43742.50
3330964116730Nonecode164Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for cold water supply including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External works 100 mm nominal dia Pipes complete as per specification and Directions of Engineer In Charge of the workm1207.141207.1470.0FalseNoneNoneFalseNoneFalse84499.80
3330965116730Nonecode165Providing and fixing PVC (S.W.R) Nahani Trap 10cms x 10cms with all fitting arrangements & all necessary accessories complete complete as per specification and Directions of Engineer In Charge of the workNos285.56285.5616.0FalseNoneNoneFalseNoneFalse4568.960
3330966116730Nonecode166Providing and fixing Chorinated Poly Vinyl Chloride (CPVC) pipes having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement & the cost of cutting chases & making good the same including testing of joints complete as per direction of Engineer in charge. Concealed work including cutting chases and making good walls etc. 20mm Nominal dia Pipes complete as per specification and Directions of Engineer In Charge of the workm491.94491.94120.0FalseNoneNoneFalseNoneFalse59032.80
3330967116730Nonecode167Providing and fixing Chorinated Poly Vinyl Chloride (CPVC) pipes conforming to IS 15778 having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, this includes jointing of pipes and fittings with one step solvent cement, trenching, refilling & testing of joints complete. as per direction of Engineer in charge. Internal work - Exposed on Walls 32mm Nominal dia Pipes complete as per specification and Directions of Engineer In Charge of the workm722.99722.9950.0FalseNoneNoneFalseNoneFalse36149.50
3330968116730Nonecode168Providing and fixing Chorinated Poly Vinyl Chloride (CPVC) pipes conforming to IS 15778 having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, this includes jointing of pipes and fittings with one step solvent cement, trenching, refilling & testing of joints complete. as per direction of Engineer in charge. external work 50 mm Nominal dia Pipes complete as per specification and Directions of Engineer In Charge of the workm935.86935.8650.0FalseNoneNoneFalseNoneFalse46793.00
3330969116730Nonecode169Providing and fixing gun metal non- return valve of approved quality (screwed end) 25 mm nominal bore 13.6.1.1 Horizontal : complete as per specification and Directions of Engineer In Charge of the workNos804.76804.7610.0FalseNoneNoneFalseNoneFalse8047.60
3330970116730Nonecode170Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g complete as per specification and Directions of Engineer In Charge of the workEach643.81643.818.0FalseNoneNoneFalseNoneFalse5150.480
3330971116730Nonecode171Providing and fixing PVC (S.W.R) Multi Floor Trap 10.0 cm X 7.5 cm X 5.0cm X 4.0 cm with all fitting arrangements & all necessary accessories complete. complete as per specification and Directions of Engineer In Charge of the workUnit316.71316.718.0FalseNoneNoneFalseNoneFalse2533.680
3330972116730Nonecode172Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 complete as per specification and Directions of Engineer In Charge of the workNo824.23824.2324.0FalseNoneNoneFalseNoneFalse19781.520
3330973116730Nonecode173Providing and fixing PTMT pillar cock of approved quality and colour. 15 mm nominal bore, 125 mm long foam flow, weighing not less than 120 gms complete as per specification and Directions of Engineer In Charge of the workEach407.57407.578.0FalseNoneNoneFalseNoneFalse3260.560
3330974116730Nonecode174Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931 complete as per specification and Directions of Engineer In Charge of the workEach941.05941.0524.0FalseNoneNoneFalseNoneFalse22585.20
3330975116730Nonecode175Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. complete as per specification and Directions of Engineer In Charge of the workEach1583.561583.568.0FalseNoneNoneFalseNoneFalse12668.480
3330976116730Nonecode176Providing and fixing unplasticised PVC connection pipe with brass unions :.15 mm nominal bore complete as per specification and Directions of Engineer In Charge of the workEach118.12118.1224.0FalseNoneNoneFalseNoneFalse2834.880
3330977116730Nonecode177Providing and placing on Terrace (at all floor levels) Polyethylene water storage tank IS: 12701 marked with cover and sutable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank complete as per specification and Directions of Engineer In Charge of the workLtr11.6811.6810000.0FalseNoneNoneFalseNoneFalse116800.00
3330978116730Nonecode178Providing and fixing on wall face unplasticised Rigid PVC rain water pipes of 150mm dia conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. complete as per specification and Directions of Engineer In Charge of the workm737.26737.2650.0FalseNoneNoneFalseNoneFalse36863.00
3330979116730Nonecode179Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. PVC pipes 200mm dia., 6 kg/sqcm & class 3 complete as per specification and Directions of Engineer In Charge of the workm1447.271447.27100.0FalseNoneNoneFalseNoneFalse144727.00
3330980116730Nonecode180Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. PVC pipes 110mm dia., 6 kg/sqcm & class 3 complete as per specification and Directions of Engineer In Charge of the workm533.48533.4850.0FalseNoneNoneFalseNoneFalse26674.00
3330981116730Nonecode181Providing and fixing SFRC frame and cover conforming to IS 12592 (part-I)-1988 and IS 12592 (part-II)- 1991 with latest amendment, including cutting slabs to the required size for the opening and fixing the cover in C.C. 1:2:4 and C.M. 1:3 plastering 20 mm thick to all exposed faces, curing for 10 days with all lead and lift with appurtenances. complete. complete as per specification and Directions of Engineer In Charge of the workSet3328.073328.072.0FalseNoneNoneFalseNoneFalse6656.140
3330982116730Nonecode182Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. complete as per specification and Directions of Engineer In Charge of the workm491.94491.9450.0FalseNoneNoneFalseNoneFalse24597.00
3330983116730Nonecode183Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required W.C. pan with ISI marked white solid plastic seat and lid complete as per specification and Directions of Engineer In Charge of the workEach7758.157758.156.0FalseNoneNoneFalseNoneFalse46548.90
3330984116730Nonecode184Providing and fixing 100 mm sand cast Iron grating for gully trap. complete as per specification and Directions of Engineer In Charge of the workEach61.0161.0112.0FalseNoneNoneFalseNoneFalse732.120
3330985116730Nonecode185Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for cold water supply including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 100 mm nominal dia Pipes complete as per specification and Directions of Engineer In Charge of the workm1207.141207.1490.0FalseNoneNoneFalseNoneFalse108642.60
3330986116730Nonecode186Providing and fixing brass bib cock of approved quality : 20 mm nominal bore complete as per specification and Directions of Engineer In Charge of the workEach395.89395.8912.0FalseNoneNoneFalseNoneFalse4750.680
3330987116730Nonecode187Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design : With common burnt clay (non modular) bricks of class designation 3.5 complete as per specification and Directions of Engineer In Charge of the workUnit2214.392214.394.0FalseNoneNoneFalseNoneFalse8857.560
3330988116730Nonecode188Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 20 mm nominal dia Pipes complete as per specification and Directions of Engineer In Charge of the workm281.67281.67100.0FalseNoneNoneFalseNoneFalse28167.00
3330989116730Nonecode189Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 32 mm nominal dia Pipes complete as per specification and Directions of Engineer In Charge of the workm482.86482.8660.0FalseNoneNoneFalseNoneFalse28971.60
3330990116730Nonecode190Supplying heavy gauge PVC conduit pipe ...... mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 19/20 mm dia 2 mm thick complete as per specification and Directions of Engineer In Charge of the workm77.8877.8890.0FalseNoneNoneFalseNoneFalse7009.20
3330991116730Nonecode191Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 6 Way complete as per specification and Directions of Engineer In Charge of the workEach259.6259.620.0FalseNoneNoneFalseNoneFalse5192.00
3330992116730Nonecode192Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box 6Module complete as per specification and Directions of Engineer In Charge of the workEach276.12276.1220.0FalseNoneNoneFalseNoneFalse5522.40
3330993116730Nonecode193Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.6A One Way Switch complete as per specification and Directions of Engineer In Charge of the workEach120.36120.3690.0FalseNoneNoneFalseNoneFalse10832.40
3330994116730Nonecode194Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.6A Three Way socket complete as per specification and Directions of Engineer In Charge of the workEach201.78201.7820.0FalseNoneNoneFalseNoneFalse4035.60
3330995116730Nonecode195Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.Stepped Fan Regulator Two Module complete as per specification and Directions of Engineer In Charge of the workEach421.26421.2618.0FalseNoneNoneFalseNoneFalse7582.680
3330996116730Nonecode196Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.. Short point upto 3m from tapping point to out let via switch box complete as per specification and Directions of Engineer In Charge of the workPoint317.42317.4215.0FalseNoneNoneFalseNoneFalse4761.30
3330997116730Nonecode197supplying and wiring adopting loop system in existing PVC conduit / casing capping using 1100 v grade , copper conductor flexible multistrand FRLS PVC insulated, 2 x1.5sq.mm cable confirming to the GTP, without switch, the other end of the wires shall be terminated with sufficient loose length in a wood /PVC cound block. complete for each outlet. Medium Poiint above 3 mts upto 6 mts. from tapping Point to out let via switch complete as per specification and Directions of Engineer In Charge of the workPoint447.22447.2218.0FalseNoneNoneFalseNoneFalse8049.960
3330998116730Nonecode198supplying and wiring adopting loop system in existing PVC conduit / casing capping using 1100 v grade , copper conductor flexible multistrand FRLS PVC insulated, 2 x1.5sq.mm cable confirming to the GTP, without switch, the other end of the wires shall be terminated with sufficient loose length in a wood /PVC cound block. complete for each outlet. Long point above 6Mtr up to 10Mtr from tapping point to out let via switch box complete as per specification and Directions of Engineer In Charge of the workPoint654.9654.940.0FalseNoneNoneFalseNoneFalse26196.00
3330999116730Nonecode199supplying and wiring adopting loop system in existing PVC conduit / casing capping using 1100 v grade , copper conductor flexible multistrand FRLS PVC insulated, 2 x1.5sq.mm cable confirming to the GTP, without switch, the other end of the wires shall be terminated with sufficient loose length in a wood /PVC cound block. complete for each outlet. Two Out let in a row above 3 mts upto 6 mts. from tapping Point to out let via switch complete as per specification and Directions of Engineer In Charge of the workPoint798.86798.868.0FalseNoneNoneFalseNoneFalse6390.880
3331000116730Nonecode200Supplying and fixing metal Fan box with Round Hook. complete as per specification and Directions of Engineer In Charge of the workEach138.06138.0618.0FalseNoneNoneFalseNoneFalse2485.080
3331001116730Nonecode201Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments 1.5 mm2 complete as per specification and Directions of Engineer In Charge of the workm30.6830.68270.0FalseNoneNoneFalseNoneFalse8283.60
3331002116730Nonecode202Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments 2.5 mm2 complete as per specification and Directions of Engineer In Charge of the workm49.5649.56270.0FalseNoneNoneFalseNoneFalse13381.20
3331003116730Nonecode203Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments 4 mm2 complete as per specification and Directions of Engineer In Charge of the workm74.3474.3490.0FalseNoneNoneFalseNoneFalse6690.60
3331004116730Nonecode204Extra for supplying 4mm th white plastic plate and covering for junction boxes of sizes … mm conduit using necessary machine screws. 80/90 mm complete as per specification and Directions of Engineer In Charge of the workNo17.717.720.0FalseNoneNoneFalseNoneFalse354.00
3331005116730Nonecode205Extra for supplying 4mm th white plastic plate and covering for junction boxes of sizes … mm conduit using necessary machine screws. 110mm complete as per specification and Directions of Engineer In Charge of the workNo24.7824.7820.0FalseNoneNoneFalseNoneFalse495.60
3331006116730Nonecode206Supplying and fixing/replaccing of 6/16/32 Amps electrical acessories on existing switch board Group-A 6 Amps Bakelite Ceiling Rose complete as per specification and Directions of Engineer In Charge of the workNo92.0492.0430.0FalseNoneNoneFalseNoneFalse2761.20
3331007116730Nonecode207Supplying and fixing/replaccing of 6/16/32 Amps electrical acessories on existing switch board Group-A 6 Amps Pendant Holder complete as per specification and Directions of Engineer In Charge of the workNo83.7883.7822.0FalseNoneNoneFalseNoneFalse1843.160
3331008116730Nonecode208Supplying and fixing regular MCB distribution boards on wall/wood board/flush mountin using required clamps, bolts, nuts with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting. Made out of 14 SWG M.S enclosure. Single Door 4 Way SP & N complete as per specification and Directions of Engineer In Charge of the workEach1464.381464.387.0FalseNoneNoneFalseNoneFalse10250.660
3331009116730Nonecode209Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32Amps SP complete as per specification and Directions of Engineer In Charge of the workEach489.7489.77.0FalseNoneNoneFalseNoneFalse3427.90
3331010116730Nonecode210Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50Hz AC with latest micro controller based, digital read out of percentage leakage current, programmable delay/auto/manual reset facility suitable to mount on DIN rail/ flush mounting on panel board. complete as per specification and Directions of Engineer In Charge of the workEach10920.910920.97.0FalseNoneNoneFalseNoneFalse76446.30
3331011116730Nonecode211Supplying and fixing regular MCB distribution boards on wall/wood board/flush mountin using required clamps, bolts, nuts with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting. Made out of 14 SWG M.S enclosure. Double door 6 Way TP & N complete as per specification and Directions of Engineer In Charge of the workEach5829.25829.26.0FalseNoneNoneFalseNoneFalse34975.20
3331012116730Nonecode212Supplying and fixing regular MCB distribution boards on wall/wood board/flush mountin using required clamps, bolts, nuts with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting. Made out of 14 SWG M.S enclosure. Double door 12 Way TP & N complete as per specification and Directions of Engineer In Charge of the workEach10307.310307.32.0FalseNoneNoneFalseNoneFalse20614.60
3331013116730Nonecode213Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32Amps DP complete as per specification and Directions of Engineer In Charge of the workEach872.02872.028.0FalseNoneNoneFalseNoneFalse6976.160
3331014116730Nonecode214Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32 Amps TPN complete as per specification and Directions of Engineer In Charge of the workEach2026.062026.065.0FalseNoneNoneFalseNoneFalse10130.30
3331015116730Nonecode215Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 50-63 Amps TPN complete as per specification and Directions of Engineer In Charge of the workEach3643.843643.841.0FalseNoneNoneFalseNoneFalse3643.840
3331016116730Nonecode216Fabricating supplying and mounting MS box made out … SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. 14SWG complete as per specification and Directions of Engineer In Charge of the workSq CM0.590.5957984.0FalseNoneNoneFalseNoneFalse34210.560
3331017116730Nonecode217Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. flat … with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. 40x40x6mm complete as per specification and Directions of Engineer In Charge of the workMtr359.9359.914.72FalseNoneNoneFalseNoneFalse5297.7280
3331018116730Nonecode218Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. THREE Pole 100 A 25 kA complete as per specification and Directions of Engineer In Charge of the workEach7181.487181.483.0FalseNoneNoneFalseNoneFalse21544.440
3331019116730Nonecode219Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. THREE Pole 125 A 25 kA complete as per specification and Directions of Engineer In Charge of the workEach10145.6410145.641.0FalseNoneNoneFalseNoneFalse10145.640
3331020116730Nonecode220Supplying and fixing of Shunt trip suitable for MCCB.CBCT. complete as per specification and Directions of Engineer In Charge of the workEach2009.542009.541.0FalseNoneNoneFalseNoneFalse2009.540
3331021116730Nonecode221Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH, KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy. complete as per specification and Directions of Engineer In Charge of the workEach10991.710991.71.0FalseNoneNoneFalseNoneFalse10991.70
3331022116730Nonecode222Supplying, fixing and wiring 50/5 to 400/5Amps 5VA burden Current Transformer. Class 0.5 accuracy with Tape Wound complete as per specification and Directions of Engineer In Charge of the workEach663.16663.163.0FalseNoneNoneFalseNoneFalse1989.480
3331023116730Nonecode223Supplying ......... amps rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 100Amps 4x30x6mm Aluminium Strips complete as per specification and Directions of Engineer In Charge of the workMtr2908.72908.74.0FalseNoneNoneFalseNoneFalse11634.80
3331024116730Nonecode224Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz 12/24V D.C. complete as per specification and Directions of Engineer In Charge of the workEach607.7607.73.0FalseNoneNoneFalseNoneFalse1823.10
3331025116730Nonecode225Supplying of .....feet -PVC Batten with integrated LED tube .... W with high quality diffuser with Life of 25000aspertheestimateitemEach814.2814.228.0FalseNoneNoneFalseNoneFalse22797.60
3331026116730Nonecode226Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling / rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall/ ceiling / Rafter / Girders complete as per specification and Directions of Engineer In Charge of the workEach143.96143.9628.0FalseNoneNoneFalseNoneFalse4030.880
3331027116730Nonecode227Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system. 48" Sweep (1200 mm) Regular model complete as per specification and Directions of Engineer In Charge of the workEach3521.123521.1218.0FalseNoneNoneFalseNoneFalse63380.160
3331028116730Nonecode228Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S'' hook with fan regulator to the existing board together with supplying and fixing 5 A. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring. complete as per specification and Directions of Engineer In Charge of the workEach201.78201.7818.0FalseNoneNoneFalseNoneFalse3632.040
3331029116730Nonecode229Supplying of .. TR Invertor type split Air conditioners suitable for operation on A/C supply single phase 50Hz 230V with hermetically sealed inverter compressor with air cooled condenser, latest R410 A/R-32 refrigerant fan motor, start & run capacitors, relay & overload protector internal unit, with one indoor & one outdoor unit The condenser unit will be placed outside the room avoid noise including standard length of suitable size copper tubing covered with nitrile rubber insulation tube. suitable capacity 3core sheathed/PVC copper cable and a battery operated wireless remote unit 5 star 1.5 Ton capacity complete as per specification and Directions of Engineer In Charge of the workEach66498.966498.98.0FalseNoneNoneFalseNoneFalse531991.20
3331030116730Nonecode230Installation charges for split type air conditioner with allied works for one indoor and one outdoor unit is to be mounted on suitable Angle Iron support upto 3.0 Ton split/cassette type A/C. complete as per specification and Directions of Engineer In Charge of the workEach3746.53746.58.0FalseNoneNoneFalseNoneFalse29972.00
3331031116730Nonecode231Supplying, erecting, testing & commissioning of ON-LINE UPS system suitable for operation on 230V, 50Hz, A/C supply, with isolation transformer all accessories complete and Excluding batteries and wiring complete. 7.5 kVA ON LINE UPS complete as per specification and Directions of Engineer In Charge of the workEach70548.6670548.661.0FalseNoneNoneFalseNoneFalse70548.660
3331032116730Nonecode232Supplying, installation, testing & commissioning of 12V DC, AH batteries in polypropylene container for U.P.S.Sealed maintenance free batteries. 75/80 AH capacity complete as per specification and Directions of Engineer In Charge of the workEach12002.9612002.964.0FalseNoneNoneFalseNoneFalse48011.840
3331033116730Nonecode233Design, supplying, erecting testing and commissioning With Out Machine Room-SS Finish of 4 stops and 10 Passengers/ Bed-cum-passenger hospital lift with speed of 1mtr per second, variablevoltage variable frequency drive, with or without machine room for the available well size, operating at 415 V 3 phase 50 cycles AC supply,powder coated / Stainless Steel car entrance doors enclosures with suitable colour vinyl flooring, LED car illumination, emergency light,intercom and fan as desired by the user, central opening / side opening door with or without attendant operation, 7 segment display buttons,call register indicator, fireman drive, SS handrails inside car, full length infrared curtain in car door, automatic rescue device with batteries,voice announcing in regional/ international languages, Braille buttons with one year warranty and maintenance with necessary scaffolding andminor civil works like fixing of guide rail, counter weight etc.,The total product and services shall adhere to IS 14665/2016 ( with latestamendments) part/section 1 to 5 with regards to general guidelines of fire safety rated doors, MRLL beams, pressure switch, manual changeover for doors during emergency, ARD of 10 times with sufficient battery back up and standard dimensions of chair car and door openings forall sizes and capacities of lifts including fitness certificate and duly observing all other safety norms prescribed and adhere to CPWDspecifications, PCB Norms, National Electricity Code (NEC), NBC-2016, IEC and Karnataka State Lifts, Escalators and Passengers ConveyersAct 2012 and Rules 2014. The Supplier shall be registered in Government Electrical Inspectorate in the State of Karnataka A. complete as per specification and Directions of Engineer In Charge of the workJob1887579.421887579.421.0FalseNoneNoneFalseNoneFalse1887579.420
3331034116730Nonecode234Providing and fixing ornamental granite column of overall height of 2585mm 430x430 sqmm octagonal ro a height of 1250mm for a height of 390mm flower design on both faces of pillar above octagonal for a height of 430mm and carving design for a height of 350mm and above that 590mm x 590mm x 160mm pedstal cap as per the approved design including quarring cutting to the requirred size and transporting the same from quarry to work spot including loading and unloading with all lead and lift etc., completeas per design and drawing. complete as per specification and Directions of Engineer In Charge of the workEach56640.056640.04.0FalseNoneNoneFalseNoneFalse226560.00
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17189738460000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17189738460000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17189738460000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17189738460000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17189738460000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneMinimum financial turnover (civil engineering construction works) not less than two times the annual payments from this contract (Rs. xxxxx Lakhs)NoneNone
NoneNoneNoneNoneSatisfactoriy completed (atleast 90%) as prime contractor at-least one such similar work of value not less than Rs. xxxxxxx (80% of estimated cost of tender)NoneNone
NoneNoneNoneNoneExecuted in any one year the following minimum quantities of work (Cement Concrete - xxxx cum, Earthwork - xxxx cum, etc) (80% of peak rate of construction)NoneNone
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid Electrical License for executing building electrificatio works and should have executed similar electrical works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid license for executing water supply / sanitary engineering works and should have executed similar works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneOwning the following key and critical equipment for this work (xxxx, xxxx, xxxx)NoneNone
NoneNoneNoneNoneLiquid assets and /or availability of credit facilities of no less than Rs. xxxxxx Lakhs (estimated cash flow for 3 months of peak construction period)NoneNone
NoneNoneNoneNoneTotal value of civl engineering works executed and payments received in the last five years (year-wise)NoneNone
NoneNoneNoneNoneList of existing commitments and ongoing worksNoneNone
NoneNoneNoneNoneList of works for which tenders already submittedNoneNone
NoneNoneNoneNoneBanker Details for referenceNoneNone
NoneNoneNoneNoneConstruction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneReports on the financial standing of the tenderer, such as profit and loss statements and auditor’s reports for the last five yearsNoneNone
NoneNoneNoneNoneQualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneList of Financial Resources with CertificatesNoneNone
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Annual Turnover CertificateTrueTechnical Bid
Registration CertificateTrueTechnical Bid
Work Done CertificateTrueTechnical Bid
Line of CreditTrueTechnical Bid
GST CertificateTrueTechnical Bid
All other criteria as per Tender DocumentTrueTechnical Bid
Bid CapacityTrueTechnical Bid
tenderWorkLocationList
tenderAddress
createdTs1718974246000
version0
createdDateNone
modifiedDateNone
blockNumberOffice of the Chief Engineer (South), Bruhat Bengaluru Mahanagara Palike, 9th Main. 9th Cross, Jayanagar 2nd Block
streetNone
cityBangalore
stateKarnataka
pin560010
tenderRecallDTONone