1719032176000 | 0 | None | None | Buildings | Construction of additional 4th, 5th & Terrace Floors with completion of balance works for G PLUS 3 Floors for KIADB Multistoried Office Building, Gandhinagar, Bengaluru. (2nd Call) | 250183704.06 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3331640 | 116760 | None | code01 | Civil: Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification Fourth Floor complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Tonne | 120759.79 | 120759.79 | 64.75 | False | None | None | False | None | False | 7819196.4025 | 0 | 3331641 | 116760 | None | code02 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification Fifth Floor complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Tonne | 121920.95 | 121920.95 | 64.75 | False | None | None | False | None | False | 7894381.5125 | 0 | 3331642 | 116760 | None | code03 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification Sixth Floor complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Tonne | 123082.1 | 123082.1 | 18.28 | False | None | None | False | None | False | 2249940.788 | 0 | 3331643 | 116760 | None | code04 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M 40 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - For Columns, lift & Shear wall. for Fourth Floor. complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Cum | 17261.97 | 17261.97 | 52.43 | False | None | None | False | None | False | 905045.0871 | 0 | 3331644 | 116760 | None | code05 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M 40 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - For Columns, lift & Shear wall. for Fifth Floor. complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Cum | 17427.89 | 17427.89 | 52.43 | False | None | None | False | None | False | 913744.2727 | 0 | 3331645 | 116760 | None | code06 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M 40 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - For Columns, lift & Shear wall. for sixth Floor. complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Cum | 17593.92 | 17593.92 | 40.87 | False | None | None | False | None | False | 719063.5104 | 0 | 3331646 | 116760 | None | code07 | Providing and laying in position Ready Mixed or Batch Mixed concrete as per IS 10262 mix design procedure for Cement Concrete works in all types of Structures other than Road works, using coarse aggregate and fine aggregate derived from natural sources, Ordinary Portland Cement (OPC) @ 75% & GGBS @ 25% proportion, admixtures to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the Engineer-in-charge. RMC M30 Grade for roof beam. for fourth Floor. complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Cum | 14324.02 | 14324.02 | 86.25 | False | None | None | False | None | False | 1235446.725 | 0 | 3331647 | 116760 | None | code08 | Providing and laying in position Ready Mixed or Batch Mixed concrete as per IS 10262 mix design procedure for Cement Concrete works in all types of Structures other than Road works, using coarse aggregate and fine aggregate derived from natural sources, Ordinary Portland Cement (OPC) @ 75% & GGBS @ 25% proportion, admixtures to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the Engineer-in-charge. RMC M30 Grade for roof slab and staircase. for fourth Floor. complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Cum | 13428.99 | 13428.99 | 121.95 | False | None | None | False | None | False | 1637665.3305 | 0 | 3331648 | 116760 | None | code09 | Providing and laying in position Ready Mixed or Batch Mixed concrete as per IS 10262 mix design procedure for Cement Concrete works in all types of Structures other than Road works, using coarse aggregate and fine aggregate derived from natural sources, Ordinary Portland Cement (OPC) @ 75% & GGBS @ 25% proportion, admixtures to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the Engineer-in-charge. RMC M30 Grade for roof beam. for Fifth Floor. complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Cum | 14461.96 | 14461.96 | 86.25 | False | None | None | False | None | False | 1247344.05 | 0 | 3331649 | 116760 | None | code10 | Providing and laying in position Ready Mixed or Batch Mixed concrete as per IS 10262 mix design procedure for Cement Concrete works in all types of Structures other than Road works, using coarse aggregate and fine aggregate derived from natural sources, Ordinary Portland Cement (OPC) @ 75% & GGBS @ 25% proportion, admixtures to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the Engineer-in-charge. RMC M30 Grade for roof slab & Staircase. for Fifth Floor. complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Cum | 13558.08 | 13558.08 | 121.95 | False | None | None | False | None | False | 1653407.856 | 0 | 3331650 | 116760 | None | code11 | Providing and laying in position Ready Mixed or Batch Mixed concrete as per IS 10262 mix design procedure for Cement Concrete works in all types of Structures other than Road works, using coarse aggregate and fine aggregate derived from natural sources, Ordinary Portland Cement (OPC) @ 75% & GGBS @ 25% proportion, admixtures to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the Engineer-in-charge. RMC M30 Grade for Staircase. for sixth Floor. complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Cum | 13687.29 | 13687.29 | 59.2 | False | None | None | False | None | False | 810287.568 | 0 | 3331651 | 116760 | None | code12 | Providing and laying autoclaved aerated cement blocks masonry with 150mm/230mm/300 mm thick AAC blocks as per IS 2185 (Part III) in super structure above plinth level up to floor I level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.- Peripheral Block Work. for B2,B1 & Ground floor. complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Cum | 10355.44 | 10355.44 | 191.54 | False | None | None | False | None | False | 1983480.9776 | 0 | 3331652 | 116760 | None | code13 | Providing and laying autoclaved aerated cement blocks masonry with 150mm/230mm/300 mm thick AAC blocks as per IS 2185 (Part III) in super structure above plinth level up to floor I level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.- Peripheral Block Work. for 1st floor. complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Cum | 10459.0 | 10459.0 | 150.43 | False | None | None | False | None | False | 1573347.37 | 0 | 3331653 | 116760 | None | code14 | Providing and laying autoclaved aerated cement blocks masonry with 150mm/230mm/300 mm thick AAC blocks as per IS 2185 (Part III) in super structure above plinth level up to floor I level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.- Peripheral Block Work. for 2nd floor. complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Cum | 10562.55 | 10562.55 | 151.0 | False | None | None | False | None | False | 1594945.05 | 0 | 3331654 | 116760 | None | code15 | Providing and laying autoclaved aerated cement blocks masonry with 150mm/230mm/300 mm thick AAC blocks as per IS 2185 (Part III) in super structure above plinth level up to floor I level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.- Peripheral Block Work. for 3rd floor. complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Cum | 10666.11 | 10666.11 | 98.46 | False | None | None | False | None | False | 1050185.1906 | 0 | 3331655 | 116760 | None | code16 | Providing and laying autoclaved aerated cement blocks masonry with 150mm/230mm/300 mm thick AAC blocks as per IS 2185 (Part III) in super structure above plinth level up to floor I level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.- Peripheral Block Work. for 4th floor. complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Cum | 10769.66 | 10769.66 | 120.22 | False | None | None | False | None | False | 1294728.5252 | 0 | 3331656 | 116760 | None | code17 | Providing and laying autoclaved aerated cement blocks masonry with 150mm/230mm/300 mm thick AAC blocks as per IS 2185 (Part III) in super structure above plinth level up to floor I level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.- Peripheral Block Work. for 5th floor. complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Cum | 10873.22 | 10873.22 | 120.22 | False | None | None | False | None | False | 1307178.5084 | 0 | 3331657 | 116760 | None | code18 | Providing and laying autoclaved aerated cement blocks masonry with 150mm/230mm/300 mm thick AAC blocks as per IS 2185 (Part III) in super structure above plinth level up to floor I level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.- Peripheral Block Work. for 5th floor. complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Cum | 10976.77 | 10976.77 | 98.21 | False | None | None | False | None | False | 1078028.5817 | 0 | 3331658 | 116760 | None | code19 | Providing 12 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) For Ceillings and Beams including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials,labour,curing complete as per specifications and as per directions of Engineer-in-charge. for B1,B2 & Ground floor. complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Sqm | 479.08 | 479.08 | 4600.01 | False | None | None | False | None | False | 2203772.7908 | 0 | 3331659 | 116760 | None | code20 | Providing 12 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) For Ceillings and Beams including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials,labour,curing complete as per specifications and as per directions of Engineer-in-charge. for 1st floor. complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Sqm | 483.87 | 483.87 | 1200.0 | False | None | None | False | None | False | 580644.0 | 0 | 3331660 | 116760 | None | code21 | Providing 12 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) For Ceillings and Beams including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials,labour,curing complete as per specifications and as per directions of Engineer-in-charge. for 2nd floor. complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Sqm | 488.66 | 488.66 | 1200.0 | False | None | None | False | None | False | 586392.0 | 0 | 3331661 | 116760 | None | code22 | Providing 12 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) For Ceillings and Beams including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials,labour,curing complete as per specifications and as per directions of Engineer-in-charge. for 3rd floor. complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Sqm | 493.45 | 493.45 | 1200.0 | False | None | None | False | None | False | 592140.0 | 0 | 3331662 | 116760 | None | code23 | Providing 12 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) For Ceillings and Beams including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials,labour,curing complete as per specifications and as per directions of Engineer-in-charge. for 4th floor. complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Sqm | 498.24 | 498.24 | 1200.0 | False | None | None | False | None | False | 597888.0 | 0 | 3331663 | 116760 | None | code24 | Providing 12 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) For Ceillings and Beams including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials,labour,curing complete as per specifications and as per directions of Engineer-in-charge. for 5th floor. complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Sqm | 503.03 | 503.03 | 1200.0 | False | None | None | False | None | False | 603636.0 | 0 | 3331664 | 116760 | None | code25 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc. for 4th floor. complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Kg | 247.04 | 247.04 | 2125.0 | False | None | None | False | None | False | 524960.0 | 0 | 3331665 | 116760 | None | code26 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc. for 5th floor. complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Kg | 249.41 | 249.41 | 2125.0 | False | None | None | False | None | False | 529996.25 | 0 | 3331666 | 116760 | None | code27 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc. for 6th floor. complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Kg | 251.79 | 251.79 | 2125.0 | False | None | None | False | None | False | 535053.75 | 0 | 3331667 | 116760 | None | code28 | Providing 20 mm cement plaster with Cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials,labour,curing complete as per specifications and as per directions of Engineer-in-charge. Internal plastering.for B2, B1 and Ground floor. complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Sqm | 556.84 | 556.84 | 2396.23 | False | None | None | False | None | False | 1334316.7132 | 0 | 3331668 | 116760 | None | code29 | Providing 20 mm cement plaster with Cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials,labour,curing complete as per specifications and as per directions of Engineer-in-charge. Internal plastering.for 1st floor. complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Sqm | 562.41 | 562.41 | 1108.48 | False | None | None | False | None | False | 623420.2368 | 0 | 3331669 | 116760 | None | code30 | Providing 20 mm cement plaster with Cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials,labour,curing complete as per specifications and as per directions of Engineer-in-charge. Internal plastering.for 2nd floor. complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Sqm | 567.98 | 567.98 | 1152.16 | False | None | None | False | None | False | 654403.8368 | 0 | 3331670 | 116760 | None | code31 | Providing 20 mm cement plaster with Cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials,labour,curing complete as per specifications and as per directions of Engineer-in-charge. Internal plastering.for 3rd floor. complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Sqm | 573.55 | 573.55 | 1400.01 | False | None | None | False | None | False | 802975.7355 | 0 | 3331671 | 116760 | None | code32 | Providing 20 mm cement plaster with Cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials,labour,curing complete as per specifications and as per directions of Engineer-in-charge. Internal plastering.for 4th floor. complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Sqm | 579.12 | 579.12 | 1152.16 | False | None | None | False | None | False | 667238.8992 | 0 | 3331672 | 116760 | None | code33 | Providing 20 mm cement plaster with Cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials,labour,curing complete as per specifications and as per directions of Engineer-in-charge. Internal plastering.for 5th floor. complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Sqm | 584.68 | 584.68 | 1152.15 | False | None | None | False | None | False | 673639.062 | 0 | 3331673 | 116760 | None | code34 | Providing 20 mm cement plaster with Cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials,labour,curing complete as per specifications and as per directions of Engineer-in-charge. Internal plastering.for 6th floor. complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Sqm | 590.25 | 590.25 | 1106.41 | False | None | None | False | None | False | 653058.5025 | 0 | 3331674 | 116760 | None | code35 | Providing 20 mm cement plaster with Cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials,labour,curing complete as per specifications and as per directions of Engineer-in-charge. External plastering. for B1, B2 and Ground Floor complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Sqm | 556.84 | 556.84 | 1126.01 | False | None | None | False | None | False | 627007.4084 | 0 | 3331675 | 116760 | None | code36 | Providing 20 mm cement plaster with Cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials,labour,curing complete as per specifications and as per directions of Engineer-in-charge. External plastering. for 1st Floor complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Sqm | 562.41 | 562.41 | 488.01 | False | None | None | False | None | False | 274461.7041 | 0 | 3331676 | 116760 | None | code37 | Providing 20 mm cement plaster with Cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials,labour,curing complete as per specifications and as per directions of Engineer-in-charge. External plastering. for 2nd Floor complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Sqm | 567.98 | 567.98 | 488.01 | False | None | None | False | None | False | 277179.9198 | 0 | 3331677 | 116760 | None | code38 | Providing 20 mm cement plaster with Cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials,labour,curing complete as per specifications and as per directions of Engineer-in-charge. External plastering. for 3rd Floor complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Sqm | 573.55 | 573.55 | 488.01 | False | None | None | False | None | False | 279898.1355 | 0 | 3331678 | 116760 | None | code39 | Providing 20 mm cement plaster with Cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials,labour,curing complete as per specifications and as per directions of Engineer-in-charge. External plastering. for 4th Floor complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Sqm | 579.12 | 579.12 | 488.01 | False | None | None | False | None | False | 282616.3512 | 0 | 3331679 | 116760 | None | code40 | Providing 20 mm cement plaster with Cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials,labour,curing complete as per specifications and as per directions of Engineer-in-charge. External plastering. for 5th Floor complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Sqm | 584.68 | 584.68 | 488.01 | False | None | None | False | None | False | 285329.6868 | 0 | 3331680 | 116760 | None | code41 | Providing 20 mm cement plaster with Cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials,labour,curing complete as per specifications and as per directions of Engineer-in-charge. External plastering. for 6th Floor complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Sqm | 590.25 | 590.25 | 488.01 | False | None | None | False | None | False | 288047.9025 | 0 | 3331681 | 116760 | None | code42 | P/F of fire proof door -Supply of Pressed steel frames of suitable section and rebate for mounting Fire Resistant Shutters of 120 minutes rating with one coat of approved brand of anti-corrosive/anti-termite primer (if required).a) CRCA (1.6mm thick)Rmtr 7.0 2. Supply of 46 mm thick Wooden Fire Resistant Shutters of 120 minutes rating similar to the prototype tested and certified at CBRI Roorkee and conforming to IS:3614 Part II/ BS: 476 Part 22/ AS: 1530.4/ ISO: 3008 comprising of Core veneered with commercial/teak ply veneering on both the sides with hardwood/teakwood lipping all-round with heat activated intumescent fire seal strips of size 10mm x 4mm on all the sides except bottom , with one coat of approved brand of primer.- Fire Rated Door.4th,5th & 6th floor. complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Sqm | 76700.0 | 76700.0 | 63.08 | False | None | None | False | None | False | 4838236.0 | 0 | 3331682 | 116760 | None | code43 | Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New Sixth/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge.- Waterproofing.For 4th floor. complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Sqm | 1102.88 | 1102.88 | 62.01 | False | None | None | False | None | False | 68389.5888 | 0 | 3331683 | 116760 | None | code44 | Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New Sixth/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge.- Waterproofing.For 5th floor. complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Sqm | 1113.49 | 1113.49 | 74.01 | False | None | None | False | None | False | 82409.3949 | 0 | 3331684 | 116760 | None | code45 | Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New Sixth/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge.- Waterproofing.For 6th floor. complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Sqm | 1124.09 | 1124.09 | 48.0 | False | None | None | False | None | False | 53956.32 | 0 | 3331685 | 116760 | None | code46 | Providing and supplying crystalline integral concrete waterproofing admixture that waterproofs concrete by forming crystals deep in the pores, capillaries and microcracks of the concrete, self-seal waterproofing compound to bridge shrinkage cracks upto 0.5mm in width & resist hydro-static pressure upto 16bar for both positive & negative pressure confirming to DIN 1048 part 5 for 56% reduction in depth of penetration against control, resistance to chloride penetration confirming to ASTMC 1202 with 64% improvement against control & protecting steel reinforcement against corrosion mixed @ 1% by weight of cementitious content in concrete. ie., integral crystaline waterproofing admix @ 0.5 kg/bag of cement. (For calculation purpose 320 kg of Cement for M-20 grade of Concrete is considered in the analysis)- Sixth Floor.complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Sqm | 846.17 | 846.17 | 126.0 | False | None | None | False | None | False | 106617.42 | 0 | 3331686 | 116760 | None | code47 | Providing and laying Vitrified floor tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.for 4th floor.complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Sqm | 1773.79 | 1773.79 | 634.0 | False | None | None | False | None | False | 1124582.86 | 0 | 3331687 | 116760 | None | code48 | Providing and laying Vitrified floor tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.for 5th floor.complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Sqm | 1790.85 | 1790.85 | 634.0 | False | None | None | False | None | False | 1135398.9 | 0 | 3331688 | 116760 | None | code49 | Providing and laying Vitrified floor tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.for 6th floor.complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Sqm | 1807.91 | 1807.91 | 515.6 | False | None | None | False | None | False | 932158.396 | 0 | 3331689 | 116760 | None | code50 | Providing and laying Vitrified floor tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.- Antiskid Tiles For Toilets.for B2 and Ground floor. complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Sqm | 1705.57 | 1705.57 | 8.0 | False | None | None | False | None | False | 13644.56 | 0 | 3331690 | 116760 | None | code51 | Providing and laying Vitrified floor tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.- Antiskid Tiles For Toilets.for 1st floor. complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Sqm | 1722.63 | 1722.63 | 72.0 | False | None | None | False | None | False | 124029.36 | 0 | 3331691 | 116760 | None | code52 | Providing and laying Vitrified floor tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.- Antiskid Tiles For Toilets.for 2nd floor. complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Sqm | 1739.68 | 1739.68 | 61.0 | False | None | None | False | None | False | 106120.48 | 0 | 3331692 | 116760 | None | code53 | Providing and laying Vitrified floor tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.- Antiskid Tiles For Toilets.for 3rd floor. complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Sqm | 1756.74 | 1756.74 | 57.0 | False | None | None | False | None | False | 100134.18 | 0 | 3331693 | 116760 | None | code54 | Providing and laying Vitrified floor tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.- Antiskid Tiles For Toilets.for 4th floor. complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Sqm | 1773.79 | 1773.79 | 52.0 | False | None | None | False | None | False | 92237.08 | 0 | 3331694 | 116760 | None | code55 | Providing and laying Vitrified floor tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.- Antiskid Tiles For Toilets.for 5th floor. complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Sqm | 1790.85 | 1790.85 | 62.0 | False | None | None | False | None | False | 111032.7 | 0 | 3331695 | 116760 | None | code56 | Providing and laying Vitrified floor tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.- Antiskid Tiles For Toilets.for 6th floor. complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Sqm | 1807.91 | 1807.91 | 40.0 | False | None | None | False | None | False | 72316.4 | 0 | 3331696 | 116760 | None | code57 | Providing and laying Vitrified tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete. Dado in toilets (1200 X 600)-.For B1 and Ground Floor. complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Sqm | 1744.51 | 1744.51 | 34.0 | False | None | None | False | None | False | 59313.34 | 0 | 3331697 | 116760 | None | code58 | Providing and laying Vitrified tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete. Dado in toilets (1200 X 600)-.For 1st Floor. complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Sqm | 1761.96 | 1761.96 | 235.0 | False | None | None | False | None | False | 414060.6 | 0 | 3331698 | 116760 | None | code59 | Providing and laying Vitrified tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete. Dado in toilets (1200 X 600)-.For 2nd Floor. complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Sqm | 1779.4 | 1779.4 | 144.0 | False | None | None | False | None | False | 256233.6 | 0 | 3331699 | 116760 | None | code60 | Providing and laying Vitrified tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete. Dado in toilets (1200 X 600)-.For 3rd Floor. complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Sqm | 1796.85 | 1796.85 | 170.0 | False | None | None | False | None | False | 305464.5 | 0 | 3331700 | 116760 | None | code61 | Providing and laying Vitrified tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete. Dado in toilets (1200 X 600)-.For 4th Floor. complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Sqm | 1814.29 | 1814.29 | 150.0 | False | None | None | False | None | False | 272143.5 | 0 | 3331701 | 116760 | None | code62 | Providing and laying Vitrified tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete. Dado in toilets (1200 X 600)-.For 5th Floor. complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Sqm | 1831.74 | 1831.74 | 188.0 | False | None | None | False | None | False | 344367.12 | 0 | 3331702 | 116760 | None | code63 | Providing and laying Vitrified tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete. Dado in toilets (1200 X 600)-.For 6th Floor. complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Sqm | 1849.18 | 1849.18 | 110.01 | False | None | None | False | None | False | 203428.2918 | 0 | 3331703 | 116760 | None | code64 | Providing and fixing 20mm thick gang saw water cut Lakared granite for cladding in CM 1:3 (1 cement : 3 coarse sand) proportion with a coat of rough plastering using CM 1:4 (1 cement : 4 fine sand), cut to required shape, pattern with paper joints, finished with cement mortar using white cement and colour pigments to match the colour of slab making through jointing with sealant, grooves in joints including cost of curing etc., complete including cost and conveyance of all materials, mortar, labour for all items of work, usage charges of machinery etc., complete as per specification- Granite Lift Lobby Cladding Lakared. for B2,B1 & Ground floors. complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Sqm | 4681.89 | 4681.89 | 45.0 | False | None | None | False | None | False | 210685.05 | 0 | 3331704 | 116760 | None | code65 | Providing and fixing 20mm thick gang saw water cut Lakared granite for cladding in CM 1:3 (1 cement : 3 coarse sand) proportion with a coat of rough plastering using CM 1:4 (1 cement : 4 fine sand), cut to required shape, pattern with paper joints, finished with cement mortar using white cement and colour pigments to match the colour of slab making through jointing with sealant, grooves in joints including cost of curing etc., complete including cost and conveyance of all materials, mortar, labour for all items of work, usage charges of machinery etc., complete as per specification- Granite Lift Lobby Cladding Lakared. for 1st floors. complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Sqm | 4728.7 | 4728.7 | 15.0 | False | None | None | False | None | False | 70930.5 | 0 | 3331705 | 116760 | None | code66 | Providing and fixing 20mm thick gang saw water cut Lakared granite for cladding in CM 1:3 (1 cement : 3 coarse sand) proportion with a coat of rough plastering using CM 1:4 (1 cement : 4 fine sand), cut to required shape, pattern with paper joints, finished with cement mortar using white cement and colour pigments to match the colour of slab making through jointing with sealant, grooves in joints including cost of curing etc., complete including cost and conveyance of all materials, mortar, labour for all items of work, usage charges of machinery etc., complete as per specification- Granite Lift Lobby Cladding Lakared. for 2nd floors. complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Sqm | 4775.52 | 4775.52 | 15.0 | False | None | None | False | None | False | 71632.8 | 0 | 3331706 | 116760 | None | code67 | Providing and fixing 20mm thick gang saw water cut Lakared granite for cladding in CM 1:3 (1 cement : 3 coarse sand) proportion with a coat of rough plastering using CM 1:4 (1 cement : 4 fine sand), cut to required shape, pattern with paper joints, finished with cement mortar using white cement and colour pigments to match the colour of slab making through jointing with sealant, grooves in joints including cost of curing etc., complete including cost and conveyance of all materials, mortar, labour for all items of work, usage charges of machinery etc., complete as per specification- Granite Lift Lobby Cladding Lakared. for 3rd floors. complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Sqm | 4822.34 | 4822.34 | 15.0 | False | None | None | False | None | False | 72335.1 | 0 | 3331707 | 116760 | None | code68 | Providing and fixing 20mm thick gang saw water cut Lakared granite for cladding in CM 1:3 (1 cement : 3 coarse sand) proportion with a coat of rough plastering using CM 1:4 (1 cement : 4 fine sand), cut to required shape, pattern with paper joints, finished with cement mortar using white cement and colour pigments to match the colour of slab making through jointing with sealant, grooves in joints including cost of curing etc., complete including cost and conveyance of all materials, mortar, labour for all items of work, usage charges of machinery etc., complete as per specification- Granite Lift Lobby Cladding Lakared. for 4th floors. complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Sqm | 4869.16 | 4869.16 | 15.0 | False | None | None | False | None | False | 73037.4 | 0 | 3331708 | 116760 | None | code69 | Providing and fixing 20mm thick gang saw water cut Lakared granite for cladding in CM 1:3 (1 cement : 3 coarse sand) proportion with a coat of rough plastering using CM 1:4 (1 cement : 4 fine sand), cut to required shape, pattern with paper joints, finished with cement mortar using white cement and colour pigments to match the colour of slab making through jointing with sealant, grooves in joints including cost of curing etc., complete including cost and conveyance of all materials, mortar, labour for all items of work, usage charges of machinery etc., complete as per specification- Granite Lift Lobby Cladding Lakared. for 5th floors. complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Sqm | 4915.98 | 4915.98 | 15.0 | False | None | None | False | None | False | 73739.7 | 0 | 3331709 | 116760 | None | code70 | Providing and fixing 20mm thick gang saw water cut Lakared granite for cladding in CM 1:3 (1 cement : 3 coarse sand) proportion with a coat of rough plastering using CM 1:4 (1 cement : 4 fine sand), cut to required shape, pattern with paper joints, finished with cement mortar using white cement and colour pigments to match the colour of slab making through jointing with sealant, grooves in joints including cost of curing etc., complete including cost and conveyance of all materials, mortar, labour for all items of work, usage charges of machinery etc., complete as per specification- Granite Lift Lobby Cladding Lakared. for 6th floors. complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Sqm | 4962.8 | 4962.8 | 15.0 | False | None | None | False | None | False | 74442.0 | 0 | 3331710 | 116760 | None | code71 | Fixing 18-20mm thick Italian marble cladding at as per detail in Drawing. (including cut to size in required shape if necessary, all other related works). Marble to be fixed with 1:3 cement mortar backing of thickness up to 20mm and cement paste of desired consistency on masonry wall as per the pattern given to correct line to the existing wall, in level & plumb, finished in grouting with pigment to match stone colour, mirror polish finish consisting of 7 coats of polish including one coat of tin oxide polish finish on top surface and finishes to the approval of the Engineer in charge. Cost to include surface preparation, chamfering/nosing, edge polishing, 10mm x 10mm grooves as specified, labour, materials, wastages, curing, cleaning, all lead, lifts, polishing/finishing as specified, necessary staging/scaffolding etc., all complete as per drawing, specifications and as directed by the Engineer in charge.-All the floors - Lift Lobby. complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Sqm | 9304.3 | 9304.3 | 135.0 | False | None | None | False | None | False | 1256080.5 | 0 | 3331711 | 116760 | None | code72 | Providing and laying plat form using prepolished, water cut/ gang saw 40mm thick telephonic Black Granite, laid on existing vertical - supports and fixing in CM 1:3 proportion. Including cutting to required shape, pattern with paper joints, including full rounding for nosing, finished with cement mortar, pointed with colour pigments to match the colour of slab making through jointing with sealant, making holes 25mm x 12mm grooves in joints including cost of all materials, mortar, labour, curing, etc.For counter tops. in all the floors. complete. complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Sqm | 7456.42 | 7456.42 | 144.0 | False | None | None | False | None | False | 1073724.48 | 0 | 3331712 | 116760 | None | code73 | Providing and fixing granite stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in- charge and finished smooth- It no 10.8 pg 70, vol 2 Urinal Partition as per drawing. For B1 & Ground floors . complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Sqm | 3620.12 | 3620.12 | 1.8 | False | None | None | False | None | False | 6516.216 | 0 | 3331713 | 116760 | None | code74 | Providing and fixing granite stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in- charge and finished smooth- It no 10.8 pg 70, vol 2 Urinal Partition as per drawing. For 1st floor . complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Sqm | 3656.32 | 3656.32 | 0.9 | False | None | None | False | None | False | 3290.688 | 0 | 3331714 | 116760 | None | code75 | Providing and fixing granite stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in- charge and finished smooth- It no 10.8 pg 70, vol 2 Urinal Partition as per drawing. For 2nd floor . complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Sqm | 3692.52 | 3692.52 | 0.9 | False | None | None | False | None | False | 3323.268 | 0 | 3331715 | 116760 | None | code76 | Providing and fixing granite stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in- charge and finished smooth- It no 10.8 pg 70, vol 2 Urinal Partition as per drawing. For 3rd floor . complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Sqm | 3728.73 | 3728.73 | 0.9 | False | None | None | False | None | False | 3355.857 | 0 | 3331716 | 116760 | None | code77 | Providing and fixing granite stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in- charge and finished smooth- It no 10.8 pg 70, vol 2 Urinal Partition as per drawing. For 4th floor . complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Sqm | 3764.93 | 3764.93 | 0.9 | False | None | None | False | None | False | 3388.437 | 0 | 3331717 | 116760 | None | code78 | Providing and fixing granite stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in- charge and finished smooth- It no 10.8 pg 70, vol 2 Urinal Partition as per drawing. For 5th floor . complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Sqm | 3801.13 | 3801.13 | 0.9 | False | None | None | False | None | False | 3421.017 | 0 | 3331718 | 116760 | None | code79 | Providing and fixing granite stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in- charge and finished smooth- It no 10.8 pg 70, vol 2 Urinal Partition as per drawing. For 6th floor . complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Sqm | 3837.33 | 3837.33 | 0.9 | False | None | None | False | None | False | 3453.597 | 0 | 3331719 | 116760 | None | code80 | Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. :- Staircase - Treads, Risers, Landing For B2,B1 and Ground floors . complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Sqm | 6915.74 | 6915.74 | 143.08 | False | None | None | False | None | False | 989504.0792 | 0 | 3331720 | 116760 | None | code81 | Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. :- Staircase - Treads, Risers, Landing For 1st floor . complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Sqm | 6984.9 | 6984.9 | 40.88 | False | None | None | False | None | False | 285542.712 | 0 | 3331721 | 116760 | None | code82 | Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. :- Staircase - Treads, Risers, Landing For 2nd floor . complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Sqm | 7054.06 | 7054.06 | 40.88 | False | None | None | False | None | False | 288369.9728 | 0 | 3331722 | 116760 | None | code83 | Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. :- Staircase - Treads, Risers, Landing For 3rd floor . complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Sqm | 7123.22 | 7123.22 | 40.88 | False | None | None | False | None | False | 291197.2336 | 0 | 3331723 | 116760 | None | code84 | Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. :- Staircase - Treads, Risers, Landing For 4th floor . complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Sqm | 7192.37 | 7192.37 | 40.88 | False | None | None | False | None | False | 294024.0856 | 0 | 3331724 | 116760 | None | code85 | Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. :- Staircase - Treads, Risers, Landing For 5th floor . complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Sqm | 7261.53 | 7261.53 | 40.88 | False | None | None | False | None | False | 296851.3464 | 0 | 3331725 | 116760 | None | code86 | Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. :- Staircase - Treads, Risers, Landing For 6th floor . complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Sqm | 7330.69 | 7330.69 | 40.88 | False | None | None | False | None | False | 299678.6072 | 0 | 3331726 | 116760 | None | code87 | Supplying and fixing in position Staircase Railing at all levels made out of SS tubular box sections and 8mm Thick SS Wires, as per detailed design & drawing, including all necessary bracket, fixtures, bolts etc and fixed on side Riser by drilling into the RCC steps with SS plate Screwed and grouting the SS sections to achieve strength. The SS railing to be supplied with Matt Finish as specified Sample to be executed for approval if necessary. Grade of SS shall be 304.- Railings - Staircase for all floors complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | m | 2183.0 | 2183.0 | 90.0 | False | None | None | False | None | False | 196470.0 | 0 | 3331727 | 116760 | None | code88 | Providing & installation of railing made of 50 x 25mm Stainless steel (Brush Finish) Grab bar and supports and 12mm toughened glass panel fixed with stud as per detail drawing. Approved finish railing to be provided of 50mm of dia as per the detail provided.-Toughened glass railing. for all the floors. complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | m | 4130.0 | 4130.0 | 90.0 | False | None | None | False | None | False | 371700.0 | 0 | 3331728 | 116760 | None | code89 | Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 L/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.-External Textured Painting. For B2, B1 and Ground Floors complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Sqm | 367.33 | 367.33 | 1126.0 | False | None | None | False | None | False | 413613.58 | 0 | 3331729 | 116760 | None | code90 | Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 L/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.-External Textured Painting. For 1st Floor complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Sqm | 371.01 | 371.01 | 488.0 | False | None | None | False | None | False | 181052.88 | 0 | 3331730 | 116760 | None | code91 | Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 L/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.-External Textured Painting. For 2nd Floor complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Sqm | 374.68 | 374.68 | 488.0 | False | None | None | False | None | False | 182843.84 | 0 | 3331731 | 116760 | None | code92 | Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 L/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.-External Textured Painting. For 3rd Floor complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Sqm | 378.35 | 378.35 | 488.0 | False | None | None | False | None | False | 184634.8 | 0 | 3331732 | 116760 | None | code93 | Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 L/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.-External Textured Painting. For 4th Floor complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Sqm | 382.03 | 382.03 | 488.0 | False | None | None | False | None | False | 186430.64 | 0 | 3331733 | 116760 | None | code94 | Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 L/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.-External Textured Painting. For 5th Floor complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Sqm | 385.7 | 385.7 | 488.0 | False | None | None | False | None | False | 188221.6 | 0 | 3331734 | 116760 | None | code95 | Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 L/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.-External Textured Painting. For 6th Floor complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Sqm | 389.37 | 389.37 | 488.0 | False | None | None | False | None | False | 190012.56 | 0 | 3331735 | 116760 | None | code96 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. -Synthetic Enamel Paint for Windows & Ventilators Grill. For Ground Floor complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Sqm | 216.77 | 216.77 | 114.75 | False | None | None | False | None | False | 24874.3575 | 0 | 3331736 | 116760 | None | code97 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. -Synthetic Enamel Paint for Windows & Ventilators Grill. For 1st Floor complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Sqm | 218.93 | 218.93 | 114.75 | False | None | None | False | None | False | 25122.2175 | 0 | 3331737 | 116760 | None | code98 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. -Synthetic Enamel Paint for Windows & Ventilators Grill. For 2nd Floor complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Sqm | 221.1 | 221.1 | 114.75 | False | None | None | False | None | False | 25371.225 | 0 | 3331738 | 116760 | None | code99 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. -Synthetic Enamel Paint for Windows & Ventilators Grill. For 3rd Floor complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Sqm | 223.27 | 223.27 | 114.75 | False | None | None | False | None | False | 25620.2325 | 0 | 3331739 | 116760 | None | code100 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. -Synthetic Enamel Paint for Windows & Ventilators Grill. For 4th Floor complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Sqm | 225.44 | 225.44 | 114.75 | False | None | None | False | None | False | 25869.24 | 0 | 3331740 | 116760 | None | code101 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. -Synthetic Enamel Paint for Windows & Ventilators Grill. For 5th Floor complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Sqm | 227.6 | 227.6 | 114.75 | False | None | None | False | None | False | 26117.1 | 0 | 3331741 | 116760 | None | code102 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. -Synthetic Enamel Paint for Windows & Ventilators Grill. For 6th Floor complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Sqm | 229.77 | 229.77 | 114.75 | False | None | None | False | None | False | 26366.1075 | 0 | 3331742 | 116760 | None | code103 | Providing & fixing of 2-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having a overall size of 60mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm X 58mm with GI reinforcement of 1mm for the frame and 1.5 mm for the sash. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 2-2.5 mm. Maximum possible size -1819mm x 1819mm (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)- Windows. For 4th Floor. with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Sqm | 7276.07 | 7276.07 | 76.51 | False | None | None | False | None | False | 556692.1157 | 0 | 3331743 | 116760 | None | code104 | Providing & fixing of 2-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having a overall size of 60mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm X 58mm with GI reinforcement of 1mm for the frame and 1.5 mm for the sash. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 2-2.5 mm. Maximum possible size -1819mm x 1819mm (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)- Windows. For 5th Floor. with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Sqm | 7346.03 | 7346.03 | 76.51 | False | None | None | False | None | False | 562044.7553 | 0 | 3331744 | 116760 | None | code105 | Providing & fixing of 2-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having a overall size of 60mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm X 58mm with GI reinforcement of 1mm for the frame and 1.5 mm for the sash. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 2-2.5 mm. Maximum possible size -1819mm x 1819mm (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)- Windows. For 6th Floor. with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Sqm | 7415.99 | 7415.99 | 76.51 | False | None | None | False | None | False | 567397.3949 | 0 | 3331745 | 116760 | None | code106 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 g/L and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 L/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.- Internal Painting. For Internal walls, Ceiling and Beam of B2,B1vand Ground Floor with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Sqm | 202.49 | 202.49 | 7000.0 | False | None | None | False | None | False | 1417430.0 | 0 | 3331746 | 116760 | None | code107 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 g/L and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 L/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.- Internal Painting. For Internal walls, Ceiling and Beam of 1st Floor with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Sqm | 204.51 | 204.51 | 2600.0 | False | None | None | False | None | False | 531726.0 | 0 | 3331747 | 116760 | None | code108 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 g/L and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 L/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.- Internal Painting. For Internal walls, Ceiling and Beam of 2nd Floor with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Sqm | 206.54 | 206.54 | 2600.0 | False | None | None | False | None | False | 537004.0 | 0 | 3331748 | 116760 | None | code109 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 g/L and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 L/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.- Internal Painting. For Internal walls, Ceiling and Beam of 3rd Floor with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Sqm | 208.56 | 208.56 | 2600.0 | False | None | None | False | None | False | 542256.0 | 0 | 3331749 | 116760 | None | code110 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 g/L and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 L/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.- Internal Painting. For Internal walls, Ceiling and Beam of 4th Floor with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Sqm | 210.59 | 210.59 | 2600.0 | False | None | None | False | None | False | 547534.0 | 0 | 3331750 | 116760 | None | code111 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 g/L and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 L/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.- Internal Painting. For Internal walls, Ceiling and Beam of 5th Floor with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Sqm | 212.61 | 212.61 | 2600.0 | False | None | None | False | None | False | 552786.0 | 0 | 3331751 | 116760 | None | code112 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 g/L and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 L/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.- Internal Painting. For Internal walls, Ceiling and Beam of 6th Floor with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Sqm | 214.64 | 214.64 | 1400.0 | False | None | None | False | None | False | 300496.0 | 0 | 3331752 | 116760 | None | code113 | Cost of Double skin roofing sheets systems with linear sheet - 0.45mm thick PPGI, width 1.060mm, crest height 30mm. Top sheet 0.5mm thk PPGL, pre painted galvalume sheet of width 1060mm, crest height 30mm. Sandwiched between linear and top sheet rock wool insulation rolls of density 48 Kg/m3, fire rated, 80 mm thk. Top sheet shall be fixed on Z sub girts of 50mm depth.Puff Sheets. For 6th Floor. Complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Sqm | 3530.56 | 3530.56 | 800.0 | False | None | None | False | None | False | 2824448.0 | 0 | 3331753 | 116760 | None | code114 | Providing and fixing Structural Steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in Charge. For 6th Floor. Complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Kg | 155.76 | 155.76 | 15000.0 | False | None | None | False | None | False | 2336400.0 | 0 | 3331754 | 116760 | None | code115 | Providing and fixing of Hexagonal Chicken mesh in two layers for walls, concrete and for the joints of concrete and masonry of mesh size from 13 - 50 mm. The dia of the wire mesh from 0.60 to 2 mm as per IS 3150-1982 using nail etc., complete as per direction of Engineer In-charge of the work For all the floors. Complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Sqm | 224.2 | 224.2 | 10954.46 | False | None | None | False | None | False | 2455989.932 | 0 | 3331755 | 116760 | None | code116 | Providng and fixing mild steel weld mesh of size 65mm x 65mm x 2.2mm as per IS 4948 (2002) for walls, concrete surface and for joints of concrete and masonry using special nail etc., completer as per the direction of Engineer Incharge includng all lead, lifts, machineries, sundries & taxes. For all the floors. Complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Sqm | 305.62 | 305.62 | 744.0 | False | None | None | False | None | False | 227381.28 | 0 | 3331756 | 116760 | None | code117 | KSRB 14.15-1: Providing and fixing Italian marble slab flooring 20mm thick with edges of slab machine cut, for flooring, treads of steps and landings laid on a bed of 25mm thick cement mortar 1:6, mix, to line and level, jointed with cement slurry curing, rubbing, polishing complete finishing with flush pointing using white cement, including cost of materials, HOM of machineries, labour, curing, complete as per specification including all applicable taxes with lead lifts etc.,. For all the floors. Complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Sqm | 12102.08 | 12102.08 | 229.0 | False | None | None | False | None | False | 2771376.32 | 0 | 3331757 | 116760 | None | code118 | Design, engineer, furnish, fabricate, package, deliver (to jobsite) and install complete: The system comprises of 2.0mm extruded L-profile fixed Louvers connected to a member on the perimeter of the fixed to the lintel, head and Jamb and the aluminium section with louvers fixed to the sub frame. All aluminium sections shall be 6063 T6 alloy or BSH9 Conforming to IS- 63400 for sub frame and the louver section. The system shall be designed to withstand a wind pressure of 1.2 Kpa as per IS 875 part 3 at all levels, elevations and heights. All Exposed exterior aluminium surfaces shall be finished with PVDF finish of minimum 45 microns (Colour as per architect’s intent) and all concealed aluminium surfaces shall be anodised finish of 25 microns (Colour as per architect intent). Rate shall include fixing of the sub frames to the RCC surface at lintel, head and jamb levels with necessary lamps,fastenning straps, nuts,bolts,washers and other fastening material of stainless steel 316 grade and corrosion resistant etc complete as per the directions of the Engineer Incharge of work including all lead, lifts, handling charges and all applicable taxes. Complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Sqm | 2360.0 | 2360.0 | 277.0 | False | None | None | False | None | False | 653720.0 | 0 | 3331758 | 116760 | None | code119 | KSRB 15.8.3 Providing and fixing plaster mesh 300mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120gms per sqm width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. Complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | m | 43.66 | 43.66 | 3738.0 | False | None | None | False | None | False | 163201.08 | 0 | 3331759 | 116760 | None | code120 | External Development work: Providing and laying Cement concrete pavement with 1:2:4 for commercial & residential building floors, hardpaths, footpaths using 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size, including finishing complete as per Engineer incharge. For Flagging concrete alround the building. Complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Cum | 8652.47 | 8652.47 | 500.0 | False | None | None | False | None | False | 4326235.0 | 0 | 3331760 | 116760 | None | code121 | Providing and laying 60mm thick factory made cement concrete paver block of approved shape and colour of M -30 grade made of C&D waste by block making machine with vibratory compaction laid in required pattern and including over 50mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge Complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Sqm | 1038.4 | 1038.4 | 1212.0 | False | None | None | False | None | False | 1258540.8 | 0 | 3331761 | 116760 | None | code122 | Providing and fixing 20mm thick gang saw water cut Lakared granite for cladding in CM 1:3 (1 cement : 3 coarse sand) proportion with a coat of rough plastering using CM 1:4 (1 cement : 4 fine sand).-Entrance canopy area Complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Sqm | 4681.89 | 4681.89 | 237.0 | False | None | None | False | None | False | 1109607.93 | 0 | 3331762 | 116760 | None | code123 | Providing and fixing of premium quality Terracota clay tiles for cladding of size 12x2x2 inches with single hole on 12mm thick cement mortar 1:3 (1 cement : 3 coarse sand) & jointed with Adhesive/cement slurry over rough plaster surface excluding cost of rough plastered surface. The work includes cost of all materials, labour charges for all items of work, usage charges for equipment, etc., complete as per specification, Complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Sqm | 2551.87 | 2551.87 | 1826.0 | False | None | None | False | None | False | 4659714.62 | 0 | 3331763 | 116760 | None | code124 | Fire Fighting: FIRE HYDRANT SYSTEM Supplying Installing, testing and commissioning of 63 mm mm dia single headed Gun mental Hydrant Valve with flanged inlet ,stop valve ,spindle and cast iron hand wheel.It has a female instantaneous outlet with Blank Capandis Hydrostatically tested to 21Kgf/cm2 pressure having a flow rate of 900 LPM at 7Kgf/cm2 of pressure with blank cap and wheel as per IS 5290 etc. complete including cost of materials, labour,usage charges of machinery complete as per specifications, Complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Each | 13629.0 | 13629.0 | 4.0 | False | None | None | False | None | False | 54516.0 | 0 | 3331764 | 116760 | None | code125 | Supplying Installing, testing and commissioning of Gunmetal Branch pipe size of 63mm dia x 19mm dia as per IS903 complete including cost of materials, labour, usage charges of machinery complete as per specifications. Complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Each | 5841.0 | 5841.0 | 4.0 | False | None | None | False | None | False | 23364.0 | 0 | 3331765 | 116760 | None | code126 | Supplying Installing, testing and commissioning of Reinforced Rubber Lined 2nos. RRL Firehose of 63mm dia 15m length as per IS8423 binded with one set of male and Female lnstantainious Gunmetal coupling as per IS903 complete including cost of materials,labour,usage charges of machinery complete as per specifications. Complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Each | 6490.0 | 6490.0 | 8.0 | False | None | None | False | None | False | 51920.0 | 0 | 3331766 | 116760 | None | code127 | Supplying Installing, testing and commissioning of Hose cabinet made out of 18gauge M.S.sheet with double glass door with lacing arrangement and painted with two coats of Fire red Enamel paint at outer is e of the Box and two coats of white enamel paint at inner sideof the box is to accomodated 2Nos.of Firehose box size20"x24"x10"complete including cost of materials,labour, usage charges of machinery complete as per specifications. Complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Each | 8437.0 | 8437.0 | 4.0 | False | None | None | False | None | False | 33748.0 | 0 | 3331767 | 116760 | None | code128 | Supplying Installing,of M.S.Pressed reel of 600mm dia swinging type motion which allows a 180deg swing and conforms to IS:884/85 or Aluminium fitting Single Piece Compact Type.including cost of materials,labour,usage charges of machinery complete as per specifications Complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Each | 6749.6 | 6749.6 | 4.0 | False | None | None | False | None | False | 26998.4 | 0 | 3331768 | 116760 | None | code129 | Supplying Installing, testing and commissioning of 19mm dia 40.0m length hose with rubber linings moothbore,reinforced of natural/synthetic fibres,a rubber cover finish shall be smooth,flute dorfabric marked with minimum thicknessof1.50mm and to withstand a working pressure of 10Kgf/sqcm confirms & tested as per IS444/IS12585 including cost of materials, labour, usage charges of machinery complete as per specifications Complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Each | 7788.0 | 7788.0 | 4.0 | False | None | None | False | None | False | 31152.0 | 0 | 3331769 | 116760 | None | code130 | Supplying and fixing of Fire duct Shutter fabricated out of M.S.sheet and frame,door shall be fixed with 4mm thick Glass,suitable Rubber beading and Locking arrangement.Rate shall be includes all fasteners etc,andcomplete shutter shall be powder coated of approved colour both inside and outside Complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Sqm | 16225.0 | 16225.0 | 4.0 | False | None | None | False | None | False | 64900.0 | 0 | 3331770 | 116760 | None | code131 | Supplying Installing, testing and commissioning of Gun metal BALL VALVE SIZE OF 25mm dia including cost of materials, labour, usage charges of machinery complete as per specifications. Complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Each | 1557.6 | 1557.6 | 4.0 | False | None | None | False | None | False | 6230.4 | 0 | 3331771 | 116760 | None | code132 | Supplying Installing, testing and commissioning of Gun metal BALL VALVE SIZE OF 19/20mm dia including cost of materials, labour, usage charges of machinery complete as per specifications. Complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Each | 1233.1 | 1233.1 | 2.0 | False | None | None | False | None | False | 2466.2 | 0 | 3331772 | 116760 | None | code133 | Supply, Installation testing and commissioning of approved make heavy tubes (Class 'C') confirming to as per IS1239 Part- I (25mm Nominal bore 4.05mm thick@ 2.97 Kg/m, 32mm Nominal bore 4.05mm thick @ 3.84 Kg/m, 40mm Nominal bore 4.05mm thick@ 4.43 Kg/m,50mm Nominal bore 4.47mm thick@ 6.17 Kg/m, 65mm Nominal bore 4.47mm thick @ 7.90 Kg/m, 80mm Nominal bore 4.85mm thick @ 10.10 Kg/m, 100mm Nominal bore 5.40mm thick@ 14.40 Kg/m,150mm Nominal bore, 5.40mm thick @ 21.20 Kg/m, Such as Tees elbows check nuts unions, Flanger, Nipples etc. including cutting welding, Trending fixing on walls, ceiling (Using 41- Tech pipe/M.S.angle supports work includes two coats of metal primer and two coats of Red enamel paint etc. including cost of materials, labour, usage charges of machinery complete as per specifications.Galvanized Iron Pipes 100mm dia. Complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | m | 3699.3 | 3699.3 | 20.0 | False | None | None | False | None | False | 73986.0 | 0 | 3331773 | 116760 | None | code134 | Supply, Installation testing and commissioning of approved make heavy tubes (Class 'C') confirming to as per IS1239 Part- I (25mm Nominal bore 4.05mm thick@ 2.97 Kg/m, 32mm Nominal bore 4.05mm thick @ 3.84 Kg/m, 40mm Nominal bore 4.05mm thick@ 4.43 Kg/m,50mm Nominal bore 4.47mm thick@ 6.17 Kg/m, 65mm Nominal bore 4.47mm thick @ 7.90 Kg/m, 80mm Nominal bore 4.85mm thick @ 10.10 Kg/m, 100mm Nominal bore 5.40mm thick@ 14.40 Kg/m,150mm Nominal bore, 5.40mm thick @ 21.20 Kg/m, Such as Tees elbows check nuts unions, Flanger, Nipples etc. including cutting welding, Trending fixing on walls, ceiling (Using 41- Tech pipe/M.S.angle supports work includes two coats of metal primer and two coats of Red enamel paint etc. including cost of materials, labour, usage charges of machinery complete as per specifications.Galvanized Iron Pipes 80mm dia. Complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | m | 2985.4 | 2985.4 | 36.0 | False | None | None | False | None | False | 107474.4 | 0 | 3331774 | 116760 | None | code135 | Supply, Installation testing and commissioning of approved make heavy tubes (Class 'C') confirming to as per IS1239 Part- I (25mm Nominal bore 4.05mm thick@ 2.97 Kg/m, 32mm Nominal bore 4.05mm thick @ 3.84 Kg/m, 40mm Nominal bore 4.05mm thick@ 4.43 Kg/m,50mm Nominal bore 4.47mm thick@ 6.17 Kg/m, 65mm Nominal bore 4.47mm thick @ 7.90 Kg/m, 80mm Nominal bore 4.85mm thick @ 10.10 Kg/m, 100mm Nominal bore 5.40mm thick@ 14.40 Kg/m,150mm Nominal bore, 5.40mm thick @ 21.20 Kg/m, Such as Tees elbows check nuts unions, Flanger, Nipples etc. including cutting welding, Trending fixing on walls, ceiling (Using 41- Tech pipe/M.S.angle supports work includes two coats of metal primer and two coats of Red enamel paint etc. including cost of materials, labour, usage charges of machinery complete as per specifications.Galvanized Iron Pipes 65mm dia.Complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | m | 2206.6 | 2206.6 | 42.0 | False | None | None | False | None | False | 92677.2 | 0 | 3331775 | 116760 | None | code136 | Supply, Installation testing and commissioning of approved make heavy tubes (Class 'C') confirming to as per IS1239 Part- I (25mm Nominal bore 4.05mm thick@ 2.97 Kg/m, 32mm Nominal bore 4.05mm thick @ 3.84 Kg/m, 40mm Nominal bore 4.05mm thick@ 4.43 Kg/m,50mm Nominal bore 4.47mm thick@ 6.17 Kg/m, 65mm Nominal bore 4.47mm thick @ 7.90 Kg/m, 80mm Nominal bore 4.85mm thick @ 10.10 Kg/m, 100mm Nominal bore 5.40mm thick@ 14.40 Kg/m,150mm Nominal bore, 5.40mm thick @ 21.20 Kg/m, Such as Tees elbows check nuts unions, Flanger, Nipples etc. including cutting welding, Trending fixing on walls, ceiling (Using 41- Tech pipe/M.S.angle supports work includes two coats of metal primer and two coats of Red enamel paint etc. including cost of materials, labour, usage charges of machinery complete as per specifications.Galvanized Iron Pipes 50mm dia.Complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | m | 1687.4 | 1687.4 | 30.0 | False | None | None | False | None | False | 50622.0 | 0 | 3331776 | 116760 | None | code137 | Supply, Installation testing and commissioning of approved make heavy tubes (Class 'C') confirming to as per IS1239 Part- I (25mm Nominal bore 4.05mm thick@ 2.97 Kg/m, 32mm Nominal bore 4.05mm thick @ 3.84 Kg/m, 40mm Nominal bore 4.05mm thick@ 4.43 Kg/m,50mm Nominal bore 4.47mm thick@ 6.17 Kg/m, 65mm Nominal bore 4.47mm thick @ 7.90 Kg/m, 80mm Nominal bore 4.85mm thick @ 10.10 Kg/m, 100mm Nominal bore 5.40mm thick@ 14.40 Kg/m,150mm Nominal bore, 5.40mm thick @ 21.20 Kg/m, Such as Tees elbows check nuts unions, Flanger, Nipples etc. including cutting welding, Trending fixing on walls, ceiling (Using 41- Tech pipe/M.S.angle supports work includes two coats of metal primer and two coats of Red enamel paint etc. including cost of materials, labour, usage charges of machinery complete as per specifications.Galvanized Iron Pipes 40mm dia.Complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | m | 1362.9 | 1362.9 | 30.0 | False | None | None | False | None | False | 40887.0 | 0 | 3331777 | 116760 | None | code138 | Supply, Installation testing and commissioning of approved make heavy tubes (Class 'C') confirming to as per IS1239 Part- I (25mm Nominal bore 4.05mm thick@ 2.97 Kg/m, 32mm Nominal bore 4.05mm thick @ 3.84 Kg/m, 40mm Nominal bore 4.05mm thick@ 4.43 Kg/m,50mm Nominal bore 4.47mm thick@ 6.17 Kg/m, 65mm Nominal bore 4.47mm thick @ 7.90 Kg/m, 80mm Nominal bore 4.85mm thick @ 10.10 Kg/m, 100mm Nominal bore 5.40mm thick@ 14.40 Kg/m,150mm Nominal bore, 5.40mm thick @ 21.20 Kg/m, Such as Tees elbows check nuts unions, Flanger, Nipples etc. including cutting welding, Trending fixing on walls, ceiling (Using 41- Tech pipe/M.S.angle supports work includes two coats of metal primer and two coats of Red enamel paint etc. including cost of materials, labour, usage charges of machinery complete as per specifications.Galvanized Iron Pipes 32mm dia. Complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | m | 1038.4 | 1038.4 | 60.0 | False | None | None | False | None | False | 62304.0 | 0 | 3331778 | 116760 | None | code139 | Supply, Installation testing and commissioning of approved make heavy tubes (Class 'C') confirming to as per IS1239 Part- I (25mm Nominal bore 4.05mm thick@ 2.97 Kg/m, 32mm Nominal bore 4.05mm thick @ 3.84 Kg/m, 40mm Nominal bore 4.05mm thick@ 4.43 Kg/m,50mm Nominal bore 4.47mm thick@ 6.17 Kg/m, 65mm Nominal bore 4.47mm thick @ 7.90 Kg/m, 80mm Nominal bore 4.85mm thick @ 10.10 Kg/m, 100mm Nominal bore 5.40mm thick@ 14.40 Kg/m,150mm Nominal bore, 5.40mm thick @ 21.20 Kg/m, Such as Tees elbows check nuts unions, Flanger, Nipples etc. including cutting welding, Trending fixing on walls, ceiling (Using 41- Tech pipe/M.S.angle supports work includes two coats of metal primer and two coats of Red enamel paint etc. including cost of materials, labour, usage charges of machinery complete as per specifications.Galvanized Iron Pipes 25mm dia. Complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | m | 908.6 | 908.6 | 280.0 | False | None | None | False | None | False | 254408.0 | 0 | 3331779 | 116760 | None | code140 | Supplying Installing, testing and commissioning of, pendent Type/Upright Type, Standard Response Standard Coverage, Sprinkler, K5.6(80),1/2”NPT, 68 Degree C, Chrome finish, UL listed.Complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Each | 486.75 | 486.75 | 196.0 | False | None | None | False | None | False | 95403.0 | 0 | 3331780 | 116760 | None | code141 | Supplying, installing, testing and commissioning of PN16 CI butterfly valves of confirming to IS 13039 with necessary nuts & bolts etc., complete etc., complete as per specificaiton with all lead and lift, loading unloading, labour, hire charges of machineries and all such incidental charges necessary for successful completion of work and as per directions of the Engineer-in-charge of the work 50mm dia CI butterfly valves .Complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Each | 5841.0 | 5841.0 | 4.0 | False | None | None | False | None | False | 23364.0 | 0 | 3331781 | 116760 | None | code142 | Supplying Installing, testing and commissioning of Ceiling Mounted powder coated Surface Finishing Mild Steel Rosette Plate including cost of materials, labour, usage charges of machinery complete as per specifications. .Complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Each | 142.78 | 142.78 | 160.0 | False | None | None | False | None | False | 22844.8 | 0 | 3331782 | 116760 | None | code143 | Pressure guage of 150 mm dia including Isolation Valve and forged siphon Tube including with all accssories as per IS:Spec. etc., complete as per specificaiton with all lead and lift, loading unloading, labour, hire charges of machineries and all such incidental charges necessary for successful completion of work and as per directions of the Engineer-in-charge of the work .Complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Each | 3764.2 | 3764.2 | 4.0 | False | None | None | False | None | False | 15056.8 | 0 | 3331783 | 116760 | None | code144 | Stainless steel braided flexible pipe (hose) for dropping sprinklers below false ceiling, pipe shall be 16 bar pressure rating and 1500 mm long 25 mm dia with union / reducer collar, clamps etc. as required. .Complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Each | 3245.0 | 3245.0 | 160.0 | False | None | None | False | None | False | 519200.0 | 0 | 3331784 | 116760 | None | code145 | Supplying, installing, testing and commissioning of PN16 CI butterfly valves of confirming to IS 13039 with necessary nuts & bolts etc., complete etc., complete as per specificaiton with all lead and lift, loading unloading, labour, hire charges of machineries and all such incidental charges necessary for successful completion of work and as per directions of the Engineer-in-charge of the work.150mm Dia CI butterfly valves .Complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Each | 16225.0 | 16225.0 | 6.0 | False | None | None | False | None | False | 97350.0 | 0 | 3331785 | 116760 | None | code146 | Supply, installation, testing and commissioning of analogue addressable Smoke Sensor detector and standard base (For Detectors/Device without inbuilt isolator, Fault Isolator or Isolator base to be provided with each detector/device) Approval: VDS/UL/EN54. Complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Each | 4283.4 | 4283.4 | 130.0 | False | None | None | False | None | False | 556842.0 | 0 | 3331786 | 116760 | None | code147 | Supply, Installation, Testing & Commissioning of Analogue Addressable loop powered Sounder & Beacon with inbuilt isolator and having Min 15 distinct sound patterns/ multitone to indicate Exit doors and direct occupants for safe and fast evacuation and 100dB output with minimum 1Hz Frequency flash rate designed for IP65 requirements and approved to operate in -10degC to +55degC temperature, complies with the essential requirement of the EMC Directive to be supplied with Junction Box, Glands and other mounting accessories for proper installation. (For Detectors / Device without inbuilt isolator, Fault Isolator or Isolator base to be provided with each detector/device) Complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Each | 6360.2 | 6360.2 | 4.0 | False | None | None | False | None | False | 25440.8 | 0 | 3331787 | 116760 | None | code148 | Supply, install, test and commissioning of Analogue addressable Manual Call Point (Resettable Type) with inbuilt isolator and LED indicator, designed for IP44 requirements and approved to operate in -10degC to +55degC temperature, complies with the essential requirement of the EMC Directive to be supplied with Barriers, Junction Box, Glands and other mounting accessories for proper installation. (For Detectors/Device without inbuilt isolator, Fault Isolator or Isolator base to be provided with each
detector/device) Approval: VDS. Complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Each | 3894.0 | 3894.0 | 4.0 | False | None | None | False | None | False | 15576.0 | 0 | 3331788 | 116760 | None | code149 | Supplying Installing, testing and commissioning of Response Indictor constists of twin LED with electronic circuit work on 24 DC enclose in PVC retangular. complete including cost of materials, labour, usage charges of machinery complete as per specifications. Complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Each | 324.5 | 324.5 | 60.0 | False | None | None | False | None | False | 19470.0 | 0 | 3331789 | 116760 | None | code150 | Supplying and fixing sheet metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc. including cost of materials, labour, usage charges of machinery complete as per specifications. Complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Each | 194.7 | 194.7 | 60.0 | False | None | None | False | None | False | 11682.0 | 0 | 3331790 | 116760 | None | code151 | Supplying and drawing of 2Core X 1.5 Sqmm copper conductor armoured cable. Complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Each | 194.7 | 194.7 | 3200.0 | False | None | None | False | None | False | 623040.0 | 0 | 3331791 | 116760 | None | code152 | Providing and Fixing Fire force board size of 3'x2' made out to Acrylic sheet of 3mm thick and fixing with Stainless Steel finished studs etc. complete including cost of materials, labour, usage charges of machinery complete as per specifications.. Complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | m | 3245.0 | 3245.0 | 4.0 | False | None | None | False | None | False | 12980.0 | 0 | 3331792 | 116760 | None | code153 | Supplying Installing, testing and commissioning of Public address system (Two way comminication type) as per requirement of Fire Force authority and which Generally comprise of Supplying Installing, testing and commissioning of Approved make 6 W.wall mounted speaker with talk back facility with store enamel painted M.S.Sheet hosing etc. complete including cost of materials, labour, usage charges of machinery complete as per specifications.. Complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Each | 3180.1 | 3180.1 | 4.0 | False | None | None | False | None | False | 12720.4 | 0 | 3331793 | 116760 | None | code154 | Supply and installation in position, testing and commissioning 6kg Fire Extinguisher Mono Ammonium Phosphate Powder 50, Stored Pressure Type, Pressure Gauge, Gross Weight 9.5 Kg, empty weight 3.5 Kg, Can Height 435MM, Diameter 160MM, Discharge Time less than 9 Sees, Controllable discharge mechanism (Squeeze grip with easy snap safety seal), Range minimum 4 meters, applicable on Class A,8,C and electrically started Fire, A Rating 3A, 8 Rating 218, Can construction : Deep drawn & Co., Mig welded, valve Construciton : Forging and Mechining, Internal Coating of Can: Epoxy powder coating, External Coating of Can: Epoxy PoIyster power coating, Sheet metal thickness:1.60MM, 5 years Warranty with instalert system with Superior quality EPDM Rubber Hosepipe etc., including cost cost of supporting materials like MS stand & accessaries if it is fixing on floor / MS brackets & accessories if it is fixing on wall,,, labour, usage charges of machinery complete as per specificed.with regards to general guidelines of fire safe. Complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Each | 3699.3 | 3699.3 | 4.0 | False | None | None | False | None | False | 14797.2 | 0 | 3331794 | 116760 | None | code155 | Supply and installation of 2 Kg C02 Gas Type Fire Extinugisher Squeeze grip type, used Unused Mechanism, Squeeze Grip, Gross Weight 9.1 Kg. empty Weight 7.1 Kg. Can Height 595MM Diameter 108MM, Discharge Time less than 8 Sees, Controllable discharge mechanism, Applicable on Class 8 & C Fire, 8 Rating 88, Can Construction : Hot spinning/Forging, Valve Construction : Forging & Machining, Internal Coating of Can : Not Applicable, External coating of Can : Spray ainting, Sheet metal thickness: 4.0MM lSI Approved, 1 Year Warranty. with instalert system with Superior quality EPDM Rubber Hosepipe etc., including cost cost of supporting materials like MS stand & accessaries if it is fixing n floor / MS brackets & accessories if it is fixing on wall,, labour, usage charges of machinery complete as per specifications. Complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Each | 7139.0 | 7139.0 | 4.0 | False | None | None | False | None | False | 28556.0 | 0 | 3331795 | 116760 | None | code156 | WATER SUPPLY: Supply , Installing, testing and commissioning approved makewhite colour European water closet(suite) constellation series wall mounted pattern type 'P' or 'S' trap with 6/3 Lts.Capacity porcelain close coupled cistern tank with all internal fittings of the cistern. The quoted price shall also include 1no. 15mm CP angle cock, CP Inlet connection pipe, CP wall flange,colour plastic solid seat and cover with rubber buffers and flap, heavy duty plastic hinges & anchor bolts etc., complete. complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | No | 8850.0 | 8850.0 | 40.0 | False | None | None | False | None | False | 354000.0 | 0 | 3331796 | 116760 | None | code157 | Supply , Installation, testing and commissioning of approved make 15mm CP health faucet with one no. of CP angle cock, CP flexible tube 1.0m long, CP crutch, nozzle etc., complete.complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | No | 1624.86 | 1624.86 | 40.0 | False | None | None | False | None | False | 64994.4 | 0 | 3331797 | 116760 | None | code158 | Supply , Installation, testing and commissioning of CP toilet paper holder fixed with counter sunk SS screws complete..complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | No | 1336.53 | 1336.53 | 40.0 | False | None | None | False | None | False | 53461.2 | 0 | 3331798 | 116760 | None | code159 | Supply , Installation, testing and commissioning of approved make 15mm CP hose bib with necessary CP wall flanges etc., complete.complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | No | 1652.0 | 1652.0 | 40.0 | False | None | None | False | None | False | 66080.0 | 0 | 3331799 | 116760 | None | code160 | Supply , Installing, testing and commissioning approved make Wash basin white colour fixed under counter with 15mm C.P. pillar cock unit 32mm dia CP waste coupling,32 mm dia heavy duty CP bottle trap with extension pipe, CP wall flanges, 1 No.15mm dia C.P. angle cocks, 1 no.C.P. flexible inlet connection pipes, CI brackets etc.,complete including silicon sealant.complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | No | 3540.0 | 3540.0 | 55.0 | False | None | None | False | None | False | 194700.0 | 0 | 3331800 | 116760 | None | code161 | Supply , Installing, testing and commissioning approved make oval Handwash white colour fixed under counter with 15mm C.P. pillar cock unit 32mm dia CP waste coupling,32 mm dia heavy duty CP bottle trap with extension pipe, CP wall flanges, 1 No.15mm dia C.P. angle cocks, 1 no.C.P. flexible inlet connection pipes, CI brackets etc.,complete including silicon sealant.complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | No | 3540.0 | 3540.0 | 4.0 | False | None | None | False | None | False | 14160.0 | 0 | 3331801 | 116760 | None | code162 | Supply , Fixing approved make CP towel ring fixed on to wall by using with SS screws etc complete.complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | No | 1180.0 | 1180.0 | 18.0 | False | None | None | False | None | False | 21240.0 | 0 | 3331802 | 116760 | None | code163 | Supply , Installation of Soap Dispenser with necessary fixing material paper roll All necessary item required to complete install the Fixture etc. Complete .complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | No | 2150.55 | 2150.55 | 35.0 | False | None | None | False | None | False | 75269.25 | 0 | 3331803 | 116760 | None | code164 | Supply , Installation, Testing & Commissioning of C.P.Gratings for floor trap with all necessary items .complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | No | 266.03 | 266.03 | 50.0 | False | None | None | False | None | False | 13301.5 | 0 | 3331804 | 116760 | None | code165 | Supply , Installation , testing and commissioning of stainless steel sink with oval Single bowl 42 x 20 x 9 of approved size manufactured from 1mm thick stainless steel, 18/8 grade SS-304 indestructible chrome nickel steel with top quality polish, with bottle trap , 40 mm dia CP waste coupling with extension flexible pipe/ UPVC rigid pipe connection of suitable dia, Table mounted single lever sink mixer with regular Swinging Spout for hot & cold water with wall flanges, etc., complete & filling with necessary sealants. Supply and fixing of granite counter shall be done by the external agency. .complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | No | 4130.0 | 4130.0 | 6.0 | False | None | None | False | None | False | 24780.0 | 0 | 3331805 | 116760 | None | code166 | Providing and fixing granite stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in- charge and finished smooth.l .Urinal Partition. complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Sqm | 3291.02 | 3291.02 | 25.0 | False | None | None | False | None | False | 82275.5 | 0 | 3331806 | 116760 | None | code167 | Supply , Installation of white vitreous China battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water (250 ml & 500 ml consumption), having water inlet from back side, All necessary item required to complete install the Fixture to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-charge. .complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | No | 13766.71 | 13766.71 | 20.0 | False | None | None | False | None | False | 275334.2 | 0 | 3331807 | 116760 | None | code168 | Supply , Installation , testing and commissioning of approved make hand drier of approved colour having twin blower integrated with timer cum infrared sensing system fully automatic which can work on 230 volts, single phase, 50 cycles etc., complete .complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | No | 3540.0 | 3540.0 | 12.0 | False | None | None | False | None | False | 42480.0 | 0 | 3331808 | 116760 | None | code169 | Supply , Installation , testing and commissioning of 75mm X 75mm floor grating of CP ring and grate with necessary fixing materials and cement concrete all-round the trap for collection of Waste water etc., complete .complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | No | 944.0 | 944.0 | 24.0 | False | None | None | False | None | False | 22656.0 | 0 | 3331809 | 116760 | None | code170 | Supply Installation of Gyeser of 5 L capacity , complete .complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | No | 8850.0 | 8850.0 | 3.0 | False | None | None | False | None | False | 26550.0 | 0 | 3331810 | 116760 | None | code171 | INTERNAL SOIL AND WASTE PIPE SYSTEM: Supplying, laying, jointing, testing and commissioning approved make PVC pipes class III 6 Kg/cm2 with solvent cement joints confirming to IS 4985 for Washing Machine & wash basin outlets. The quoted rate shall include necessary chisling in walls making good the same in C.M. 1:4, encasing the pipes in toilet sunken and under ground in M-15 as per specifications 100 mm thk. all around with necessary shuttering arrangement, necessary fittings viz.,elbows,tees etc.complete. 40mm dia.complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Rmtr | 118.0 | 118.0 | 60.0 | False | None | None | False | None | False | 7080.0 | 0 | 3331811 | 116760 | None | code172 | Supplying, laying, jointing, testing and commissioning approved make PVC pipes class III 6 Kg/cm2 with solvent cement joints confirming to IS 4985 for Washing Machine & wash basin outlets. The quoted rate shall include necessary chisling in walls making good the same in C.M. 1:4, encasing the pipes in toilet sunken and under ground in M-15 as per specifications 100 mm thk. all around with necessary shuttering arrangement, necessary fittings viz.,elbows,tees etc.complete. 50mm dia.complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Rmtr | 177.0 | 177.0 | 70.0 | False | None | None | False | None | False | 12390.0 | 0 | 3331812 | 116760 | None | code173 | Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. (internal piping in toilet slab).75mm nominal dia pipes - Waste Pipe- Toilet, Kitchen. complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Rmtr | 375.12 | 375.12 | 220.0 | False | None | None | False | None | False | 82526.4 | 0 | 3331813 | 116760 | None | code174 | Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. (internal piping in toilet slab).110mm nominal dia pipes - Soil Pipe. complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Rmtr | 499.73 | 499.73 | 145.0 | False | None | None | False | None | False | 72460.85 | 0 | 3331814 | 116760 | None | code175 | Supplying, installing, testing and commissioning of approved make PVC Pipes 10kg (Solvent joint). The fittings and specials such as tees, elbows, couplers, bends, enlargers etc.,where connection with metal is to be made including necessary drilling holes, chasing brick walls/ RCC walls and making the same good in cement mortar 1 : 1 restore the same original condition neatly as directed by the Engineer in - charge. Including hanger supports, grip bolts & Clamps etc.,25mm dia .complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Rmtr | 177.0 | 177.0 | 110.0 | False | None | None | False | None | False | 19470.0 | 0 | 3331815 | 116760 | None | code176 | Providing and fixing PVC (S.W.R) Multi Floor Trap 10.0 cm X 7.5 cm X 5.0 cm X 4.0 cm with all fitting arrangements & all necessary accessories complete.110 x 75 mm dia (50 mm water seal). complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Each | 316.71 | 316.71 | 120.0 | False | None | None | False | None | False | 38005.2 | 0 | 3331816 | 116760 | None | code177 | Supplying, laying, jointing, testing and comissioning of approved make PVC floor drain with C P grating with required concrete encasing all around, complete. 110 x 75 mm dia (20 mm water seal) Balconcy - Nahi trap .complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | No | 590.0 | 590.0 | 30.0 | False | None | None | False | None | False | 17700.0 | 0 | 3331817 | 116760 | None | code178 | Supplying & fixing of PVC self cleansing type nahani trap with outlet confirming to IS 14735 with necessary cement concrete , with or without vent arm, etc., complete as per specifications including cutting and making good and complete.110 mm x 75 mm dia.complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | No | 739.15 | 739.15 | 125.0 | False | None | None | False | None | False | 92393.75 | 0 | 3331818 | 116760 | None | code179 | Drilling with core cutting machine in RCC beams, slabs, floors etc., for alying pipes and rendering the same in RCC 1:2:4, finishing the same to the satisfication of the owner or his authorised representative etc., including nominal reniforcement wherever required complete.65 mm dia .complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | No | 1430.51 | 1430.51 | 2.0 | False | None | None | False | None | False | 2861.02 | 0 | 3331819 | 116760 | None | code180 | Drilling with core cutting machine in RCC beams, slabs, floors etc., for alying pipes and rendering the same in RCC 1:2:4, finishing the same to the satisfication of the owner or his authorised representative etc., including nominal reniforcement wherever required complete.110 mm dia .complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | No | 1487.86 | 1487.86 | 16.0 | False | None | None | False | None | False | 23805.76 | 0 | 3331820 | 116760 | None | code181 | Drilling with core cutting machine in RCC beams, slabs, floors etc., for alying pipes and rendering the same in RCC 1:2:4, finishing the same to the satisfication of the owner or his authorised representative etc., including nominal reniforcement wherever required complete.125 mm dia.complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | No | 1629.64 | 1629.64 | 15.0 | False | None | None | False | None | False | 24444.6 | 0 | 3331821 | 116760 | None | code182 | Supplying, Installaing, Testing & Commissioning of approved make Balcony rainwater outlet with 75 mm dia PVC bend & SS grating on top including fixing in cement mortar 1:4 and Bore Packing etc., complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Each | 366.39 | 366.39 | 30.0 | False | None | None | False | None | False | 10991.7 | 0 | 3331822 | 116760 | None | code183 | Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. (External piping in shaft ). 110 mm dia(Soil Pipe).complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Rmtr | 499.73 | 499.73 | 150.0 | False | None | None | False | None | False | 74959.5 | 0 | 3331823 | 116760 | None | code184 | Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. (External piping in shaft ). 150 mm dia(Soil Pipe).complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Rmtr | 996.86 | 996.86 | 55.0 | False | None | None | False | None | False | 54827.3 | 0 | 3331824 | 116760 | None | code185 | Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. (External piping in shaft ).63 mm dia ( Vent).complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Rmtr | 330.4 | 330.4 | 95.0 | False | None | None | False | None | False | 31388.0 | 0 | 3331825 | 116760 | None | code186 | Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. (External piping in shaft ).75 mm dia (Vent Pipe) & (wastePipe).complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Rmtr | 375.12 | 375.12 | 190.0 | False | None | None | False | None | False | 71272.8 | 0 | 3331826 | 116760 | None | code187 | Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. (External piping in shaft ).110 mm dia.complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Rmtr | 499.73 | 499.73 | 45.0 | False | None | None | False | None | False | 22487.85 | 0 | 3331827 | 116760 | None | code188 | Supplying, laying, jointing, testing and commissioning approved make PVC vent cowl.63 mm dia.complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | No | 118.0 | 118.0 | 10.0 | False | None | None | False | None | False | 1180.0 | 0 | 3331828 | 116760 | None | code189 | Supplying, laying, jointing, testing and commissioning approved make PVC vent cowl.75 mm dia.complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | No | 129.8 | 129.8 | 15.0 | False | None | None | False | None | False | 1947.0 | 0 | 3331829 | 116760 | None | code190 | Supplying, laying, jointing, testing and commissioning approved make PVC vent cowl.110 mm dia.complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | No | 177.0 | 177.0 | 18.0 | False | None | None | False | None | False | 3186.0 | 0 | 3331830 | 116760 | None | code191 | Supplying, laying, jointing, testing and commissioning approved make PVC vent cowl.160 mm dia.complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | No | 354.0 | 354.0 | 4.0 | False | None | None | False | None | False | 1416.0 | 0 | 3331831 | 116760 | None | code192 | INTERNAL WATER SUPPLY SYSTEM: Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.20 mm dia .complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Rmtr | 491.94 | 491.94 | 325.0 | False | None | None | False | None | False | 159880.5 | 0 | 3331832 | 116760 | None | code193 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc..25 mm dia .complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Rmtr | 619.15 | 619.15 | 285.0 | False | None | None | False | None | False | 176457.75 | 0 | 3331833 | 116760 | None | code194 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 32 mm dia .complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Rmtr | 722.99 | 722.99 | 20.0 | False | None | None | False | None | False | 14459.8 | 0 | 3331834 | 116760 | None | code195 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 40 mm dia .complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Rmtr | 850.78 | 850.78 | 70.0 | False | None | None | False | None | False | 59554.6 | 0 | 3331835 | 116760 | None | code196 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :25 mm dia. complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | No | 430.94 | 430.94 | 85.0 | False | None | None | False | None | False | 36629.9 | 0 | 3331836 | 116760 | None | code197 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete 32 mm dia .complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | No | 952.26 | 952.26 | 2.0 | False | None | None | False | None | False | 1904.52 | 0 | 3331837 | 116760 | None | code198 | VERTICAL SHAFT & TERRACE - WATER SUPPLY SYSTEM: Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.Terrace & Shaft Piping & at locations wherever directed by EIC. 25 mm dia .complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Rmtr | 384.21 | 384.21 | 65.0 | False | None | None | False | None | False | 24973.65 | 0 | 3331838 | 116760 | None | code199 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.Terrace & Shaft Piping & at locations wherever directed by EIC. 32 mm dia .complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Rmtr | 482.86 | 482.86 | 65.0 | False | None | None | False | None | False | 31385.9 | 0 | 3331839 | 116760 | None | code200 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.Terrace & Shaft Piping & at locations wherever directed by EIC. 40 mm dia .complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Rmtr | 619.15 | 619.15 | 70.0 | False | None | None | False | None | False | 43340.5 | 0 | 3331840 | 116760 | None | code201 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.Terrace & Shaft Piping & at locations wherever directed by EIC. 50 mm dia-PRM line .complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Rmtr | 935.86 | 935.86 | 165.0 | False | None | None | False | None | False | 154416.9 | 0 | 3331841 | 116760 | None | code202 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.Terrace & Shaft Piping & at locations wherever directed by EIC. 65 mm dia- Terrace Ring Main .complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Rmtr | 1817.2 | 1817.2 | 135.0 | False | None | None | False | None | False | 245322.0 | 0 | 3331842 | 116760 | None | code203 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : Terrace and shaft at location wherever directed by EIC. 25 mm dia (Screwed ends) .complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | No | 430.94 | 430.94 | 10.0 | False | None | None | False | None | False | 4309.4 | 0 | 3331843 | 116760 | None | code204 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : Terrace and shaft at location wherever directed by EIC. 32 mm dia (Screwed ends) .complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | No | 952.61 | 952.61 | 10.0 | False | None | None | False | None | False | 9526.1 | 0 | 3331844 | 116760 | None | code205 | Supplying, installing, testing and commissioning of CI butterfly valves PN 10 with standard lever confirming to IS standard 13039 with necessary flanges, nuts and bolts etc., complete. 50 mm dia - PRM .complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | No | 5575.5 | 5575.5 | 6.0 | False | None | None | False | None | False | 33453.0 | 0 | 3331845 | 116760 | None | code206 | Supplying, installing, testing and commissioning of CI butterfly valves PN 10 with standard lever confirming to IS standard 13039 with necessary flanges, nuts and bolts etc., complete. 65 mm dia -Terrace Ring .complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | No | 7004.42 | 7004.42 | 15.0 | False | None | None | False | None | False | 105066.3 | 0 | 3331846 | 116760 | None | code207 | Supplying, installing, testing and commissioning of CI butterfly valves PN 10 with standard lever confirming to IS standard 13039 with necessary flanges, nuts and bolts etc., complete. 80 mm dia -Terrace Ring .complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | No | 11879.0 | 11879.0 | 5.0 | False | None | None | False | None | False | 59395.0 | 0 | 3331847 | 116760 | None | code208 | Providing, fixing, testing and commissioning of Brass body nickel plated automatic air release valves with necessary GI Specials, thread, holdtite, brass spindle, NBR and elastomeric, stainless steel spring polypropylenic float at the top most points of water supply distribution ring main. 20 mm dia.complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | No | 1991.84 | 1991.84 | 16.0 | False | None | None | False | None | False | 31869.44 | 0 | 3331848 | 116760 | None | code209 | Providing and fixing gun metal non- return valve of approved quality (screwed end) : Vertical, complete. 65 mm dia - Terrcae Pump Delivery. complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | No | 3160.63 | 3160.63 | 4.0 | False | None | None | False | None | False | 12642.52 | 0 | 3331849 | 116760 | None | code210 | Providing & fixing suction CI body Y strainer (PN 10) with MS flange of suitable length fabricated from 16 gauge SS sheet with 3 mm slots with necessary nuts and bolts, neoprene rubber gaskets, flanges etc, complete. 80 mm dia - Pump Suctioncomplete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | No | 4720.0 | 4720.0 | 1.0 | False | None | None | False | None | False | 4720.0 | 0 | 3331850 | 116760 | None | code211 | Supplying and laying of P.C.C support blocks of 1 : 2 : 4 concrete mix of sizes as given below for pipe supports at terrace level to run the terrace water supply pipes with necessary shuttering, plastering, pipe fixing anchors etc., complete as per specifications. complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Cum | 2230.2 | 2230.2 | 80.0 | False | None | None | False | None | False | 178416.0 | 0 | 3331851 | 116760 | None | code212 | Supplying, installing ,testing and commissioning of Pressure gauges of suitable range for pump sets and pipe lines with Ball valves, siphon, Fittings like unions / colours / reducers etc. Glycerine filled pressure gauges to use on pump discharge lines.- 80/65 mm dia complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | No | 3213.08 | 3213.08 | 6.0 | False | None | None | False | None | False | 19278.48 | 0 | 3331852 | 116760 | None | code213 | RAIN WATER & BALCONCY: Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 100 mm diameter Terrace Rain water & Balcony Rain water complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Rmtr | 377.72 | 377.72 | 175.0 | False | None | None | False | None | False | 66101.0 | 0 | 3331853 | 116760 | None | code214 | Supplying, fixing, testing and commissioning of leaf trap with kurra made out of PVC/FRP with aluminium grating for rainwater outlets on terrace including all necessary grouting 110 mm dia complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | No | 2950.0 | 2950.0 | 5.0 | False | None | None | False | None | False | 14750.0 | 0 | 3331854 | 116760 | None | code215 | PUMP ROOM: Providing, Laying and Fixing of GI pipes conforming to IS 1239:1990 with latest amendments complete with GI fittings (excluding the cost of fittings) with cuts and threads wherever necessary, including testing for water tightness, with all lead and commissioning. (contractor will make his own arrangements for procuring water for testing) For:Heavy Duty GI Pipe etc. complete. 100 mm dia. complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Rmtr | 1832.78 | 1832.78 | 35.0 | False | None | None | False | None | False | 64147.3 | 0 | 3331855 | 116760 | None | code216 | Providing, Laying and Fixing of GI pipes conforming to IS 1239:1990 with latest amendments complete with GI fittings (excluding the cost of fittings) with cuts and threads wherever necessary, including testing for water tightness, with all lead and commissioning. (contractor will make his own arrangements for procuring water for testing) For:Heavy Duty GI Pipe etc. complete. 80 mm dia. complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Rmtr | 1309.68 | 1309.68 | 30.0 | False | None | None | False | None | False | 39290.4 | 0 | 3331856 | 116760 | None | code217 | Supplying, installing, testing and commissioning of approved make butterfly valve (upto 150mm dia with hand lever operation & above with gear box operation). Tested to a pressure not less than 16 Kg/Sq.cm. Including rubber gasket, G.I. flanges, G.I. nuts, G.I. bolts, G.I. washers & painting complete as required. 100 mm dia complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | No | 15237.05 | 15237.05 | 5.0 | False | None | None | False | None | False | 76185.25 | 0 | 3331857 | 116760 | None | code218 | Supplying, installing, testing and commissioning of approved make butterfly valve (upto 150mm dia with hand lever operation & above with gear box operation). Tested to a pressure not less than 16 Kg/Sq.cm. Including rubber gasket, G.I. flanges, G.I. nuts, G.I. bolts, G.I. washers & painting complete as required. 80 mm dia (PRM to Header) complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | No | 11879.0 | 11879.0 | 5.0 | False | None | None | False | None | False | 59395.0 | 0 | 3331858 | 116760 | None | code219 | Supplying, installing, testing and commissioning of approved make butterfly valve (upto 150mm dia with hand lever operation & above with gear box operation). Tested to a pressure not less than 16 Kg/Sq.cm. Including rubber gasket, G.I. flanges, G.I. nuts, G.I. bolts, G.I. washers & painting complete as required.50 mm dia complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | No | 5575.5 | 5575.5 | 5.0 | False | None | None | False | None | False | 27877.5 | 0 | 3331859 | 116760 | None | code220 | Providing and fixing gun metal non- return valve of approved quality (screwed end) : (For solar water inlet pipe) 80 mm dia (PRM to Header) complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | No | 4667.61 | 4667.61 | 4.0 | False | None | None | False | None | False | 18670.44 | 0 | 3331860 | 116760 | None | code221 | Supplying, installing, testing and commissioning approved make "Y" strainer with necessary nuts & bolts etc.,complete. 100mm dia complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | No | 8176.22 | 8176.22 | 1.0 | False | None | None | False | None | False | 8176.22 | 0 | 3331861 | 116760 | None | code222 | Supply, fabrication, fixing, testing and commissioning of GI Class" C "puddle flanged pipes of required sizes for inlet, outlet, vent and overflow pipes for Over Head, UG Sump Tank, STP . The puddle flanged pipes shall be threaded end upto 80 mm dia and flanged ends above 100 mm dia. All the puddle flanged pipes, plates and fittings shall be galvanized after fabrication as per IS specifications: PUDDLE FLANGE - FOR OHT LENGTH OF PUDDLE FLANGE 500 MM,Approx. depth = 3.00 Mts. C.I. manhole frame and cover (medium duty-100 kgs )-600mm x600mm size Inlet puddle flanges, 200 mm dia. All puddle flanges to be hot dip galvanised. complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Each | 3504.6 | 3504.6 | 3.0 | False | None | None | False | None | False | 10513.8 | 0 | 3331862 | 116760 | None | code223 | Supply, fabrication, fixing, testing and commissioning of GI Class" C "puddle flanged pipes of required sizes for inlet, outlet, vent and overflow pipes for Over Head, UG Sump Tank, STP . The puddle flanged pipes shall be threaded end upto 80 mm dia and flanged ends above 100 mm dia. All the puddle flanged pipes, plates and fittings shall be galvanized after fabrication as per IS specifications: PUDDLE FLANGE - FOR OHT LENGTH OF PUDDLE FLANGE 500 MM,Approx. depth = 3.00 Mts. C.I. manhole frame and cover (medium duty-100 kgs )-600mm x600mm size Inlet puddle flanges, 150 mm dia. All puddle flanges to be hot dip galvanised. complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Each | 3186.0 | 3186.0 | 3.0 | False | None | None | False | None | False | 9558.0 | 0 | 3331863 | 116760 | None | code224 | Supply, fabrication, fixing, testing and commissioning of GI Class" C "puddle flanged pipes of required sizes for inlet, outlet, vent and overflow pipes for Over Head, UG Sump Tank, STP . The puddle flanged pipes shall be threaded end upto 80 mm dia and flanged ends above 100 mm dia. All the puddle flanged pipes, plates and fittings shall be galvanized after fabrication as per IS specifications: PUDDLE FLANGE - FOR OHT LENGTH OF PUDDLE FLANGE 500 MM,Approx. depth = 3.00 Mts. C.I. manhole frame and cover (medium duty-100 kgs )-600mm x600mm size Inlet puddle flanges, 100 mm dia. All puddle flanges to be hot dip galvanised. complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Each | 2773.0 | 2773.0 | 5.0 | False | None | None | False | None | False | 13865.0 | 0 | 3331864 | 116760 | None | code225 | Supply, fabrication, fixing, testing and commissioning of GI Class" C "puddle flanged pipes of required sizes for inlet, outlet, vent and overflow pipes for Over Head, UG Sump Tank, STP . The puddle flanged pipes shall be threaded end upto 80 mm dia and flanged ends above 100 mm dia. All the puddle flanged pipes, plates and fittings shall be galvanized after fabrication as per IS specifications: PUDDLE FLANGE - FOR OHT LENGTH OF PUDDLE FLANGE 500 MM,Approx. depth = 3.00 Mts. C.I. manhole frame and cover (medium duty-100 kgs )-600mm x600mm size Inlet puddle flanges, 80 mm dia.All puddle flanges to be hot dip galvanised. complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Each | 2548.8 | 2548.8 | 6.0 | False | None | None | False | None | False | 15292.8 | 0 | 3331865 | 116760 | None | code226 | Supply, fabrication, fixing, testing and commissioning of GI Class" C "puddle flanged pipes of required sizes for inlet, outlet, vent and overflow pipes for Over Head, UG Sump Tank, STP . The puddle flanged pipes shall be threaded end upto 80 mm dia and flanged ends above 100 mm dia. All the puddle flanged pipes, plates and fittings shall be galvanized after fabrication as per IS specifications: PUDDLE FLANGE - FOR OHT LENGTH OF PUDDLE FLANGE 500 MM,Approx. depth = 3.00 Mts. C.I. manhole frame and cover (medium duty-100 kgs )-600mm x600mm size Inlet puddle flanges, 65 mm dia.All puddle flanges to be hot dip galvanised. complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Each | 2230.2 | 2230.2 | 4.0 | False | None | None | False | None | False | 8920.8 | 0 | 3331866 | 116760 | None | code227 | Supply, fabrication, fixing, testing and commissioning of GI Class" C "puddle flanged pipes of required sizes for inlet, outlet, vent and overflow pipes for Over Head, UG Sump Tank, STP . The puddle flanged pipes shall be threaded end upto 80 mm dia and flanged ends above 100 mm dia. All the puddle flanged pipes, plates and fittings shall be galvanized after fabrication as per IS specifications: PUDDLE FLANGE - FOR OHT LENGTH OF PUDDLE FLANGE 500 MM,Approx. depth = 3.00 Mts. C.I. manhole frame and cover (medium duty-100 kgs )-600mm x600mm size Inlet puddle flanges, 50 mm dia. All puddle flanges to be hot dip galvanised.complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Each | 1911.6 | 1911.6 | 5.0 | False | None | None | False | None | False | 9558.0 | 0 | 3331867 | 116760 | None | code228 | Supply, fabrication, fixing, testing and commissioning of GI Class" C "puddle flanged pipes of required sizes for inlet, outlet, vent and overflow pipes for Over Head, UG Sump Tank, STP . The puddle flanged pipes shall be threaded end upto 80 mm dia and flanged ends above 100 mm dia. All the puddle flanged pipes, plates and fittings shall be galvanized after fabrication as per IS specifications: PUDDLE FLANGE - FOR OHT LENGTH OF PUDDLE FLANGE 500 MM,Approx. depth = 3.00 Mts. C.I. manhole frame and cover (medium duty-100 kgs )-600mm x600mm size Outlet puddle flanges , 100 mm dia. All puddle flanges to be hot dip galvanised.complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Each | 2773.0 | 2773.0 | 6.0 | False | None | None | False | None | False | 16638.0 | 0 | 3331868 | 116760 | None | code229 | Supply, fabrication, fixing, testing and commissioning of GI Class" C "puddle flanged pipes of required sizes for inlet, outlet, vent and overflow pipes for Over Head, UG Sump Tank, STP . The puddle flanged pipes shall be threaded end upto 80 mm dia and flanged ends above 100 mm dia. All the puddle flanged pipes, plates and fittings shall be galvanized after fabrication as per IS specifications: PUDDLE FLANGE - FOR OHT LENGTH OF PUDDLE FLANGE 500 MM,Approx. depth = 3.00 Mts. C.I. manhole frame and cover (medium duty-100 kgs )-600mm x600mm size Outlet puddle flanges , 80 mm dia. All puddle flanges to be hot dip galvanised.complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Each | 2548.8 | 2548.8 | 6.0 | False | None | None | False | None | False | 15292.8 | 0 | 3331869 | 116760 | None | code230 | Swan neck bend for Vent pipe with mosquito proof mesh (100mm dia) complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | No | 1652.0 | 1652.0 | 4.0 | False | None | None | False | None | False | 6608.0 | 0 | 3331870 | 116760 | None | code231 | Swan neck bend for Vent pipe with mosquito proof mesh (80mm dia) complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | No | 1534.0 | 1534.0 | 4.0 | False | None | None | False | None | False | 6136.0 | 0 | 3331871 | 116760 | None | code232 | Supplying, installing, testing and commissioning of inlet, outlet, vent and overflow pipes, fittings with CI frame and cover for following sizes to overhead water tank, UG Tank, Storm water, waste water collection sump complete with step irons as shown on the drawings etc., complete, accessories comprising of the following : 600 x 600 - CI manhole frame and cover as per IS 3989 -1984 (21kgs.) - OHT complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | No | 5310.0 | 5310.0 | 8.0 | False | None | None | False | None | False | 42480.0 | 0 | 3331872 | 116760 | None | code233 | Supply, installation, testing & commissioning of Microprocessor based fully automatic Electronic water level controller with indicator and the following parameters facility: 1) Auto. 2) Manual 3) Sump Low. 4) Sump high. 5) Over head Tank Low. 6) Over Head Tank High. 7) Pump on. 8) Pump Fault. 9) Water flow indication. 10) Voltage display. Etc., with float switch (PVC Moulded Magnetic Float Sensors ) of approved make as required by the site engineer. (Including the wiring of 6 Core 0.75 sqmm / cat 6 cable with 25mm dia PVC conduit). complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Each | 14750.0 | 14750.0 | 4.0 | False | None | None | False | None | False | 59000.0 | 0 | 3331873 | 116760 | None | code234 | Supplying, installing, testing and commissioning approved make centrifugal pump made of SS Construction suitable for building application. Thequoted rate shall also include for auto lvl.controller. providing necessary safety devices viz. dry run protection, over load relays etc., complete working on 230V, 50Hz, 3Ph, with starter, Duty of pumps : 5 Cum/Hr @ 20m Head.1 No. Working + 1 No. Stand By complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Set | 79650.0 | 79650.0 | 1.0 | False | None | None | False | None | False | 79650.0 | 0 | 3331874 | 116760 | None | code235 | Supplying, Installing, testing and commissioning approved make Terrace booster pump system comprising of Vertical Centrifugal pump mounted on a skid with company supplied automatic control panel overload relays,on-off push button switches, phase including indicator lamps,dry run protection relays, pressure Switches &guages, 1no. FRP pressure vessel of 24 Lts. Cap.The pump shall run on 440V, 3ph, 50Hz electricsupply etc., complete(Terrace Booster Pump) (Terrace Booster Pump ) - 1 working (CSSD) + 1 stand by Duty of pumps : 3.0 Cum/hr@35m head cut - in pressure = 3.0Bars cut - off pressure = 4.0Bars complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Set | 112985.0 | 112985.0 | 1.0 | False | None | None | False | None | False | 112985.0 | 0 | 3331875 | 116760 | None | code236 | EXTERNAL SEWAGE SYSTEM: Supplying, fixing and testing RCC/ PVC gully trap chamber of internal size 300 mm x 300 mm with rebated top square shape 150 mm x 150 mm x100 mm dia outlet set in 75 mm thick PCC 1 : 4 : 8 bed, construction of 230 mm thick masonry chamber in CM 1 : 4, with internal plastering of 12 mm thk in CM 1 : 3 and external plastering 12 mm thick in CM 1 : 6, including finishing smooth inside surface of the chamber with cement rendering with necessary benching and channelling, supply and fixing of 450 mm x 450 mm size CI frame and cover (weight of frame and cover not less than 10 Kgs.) / FRP Cover set in PCC 1 : 2 : 4 as per the detailed drawing .The quoted rate shall also include necessary excavation, backfilling, ramming, disposing off surplus earth etc., complete as per specifications & drawing or as instructed from EIC. complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Each | 4033.48 | 4033.48 | 8.0 | False | None | None | False | None | False | 32267.84 | 0 | 3331876 | 116760 | None | code237 | Construction of inspection chamber with 230 mm thick best quality masonary blocks in CM 1 : 4 laid over a bed of 150 mm thick PCC 1 : 4 : 8, walls plastered smooth, internal plastering 12 mm thk in CM 1 : 3 and external plastering 12 mm thick in CM 1 : 6 including finishing smooth inside surface of the chamber with cement rendering, curing etc. The quoted rate to include excavation in all types of soil, necessary wooden / steel form work, back filling of the chamber sides with the excavated soil, disposing of the surplus earth after back filling with initial lead of 30 metres or as directed, including, lift, benching and channelling shall be finished smooth, in PCC 1 : 2 : 4. Providing and fixing ofRCC Cover SFRC manhole frame and cover, set in PCC 1 : 2 : 4 with Thermo plastic moulded steps for chambers beyond 900 mm dept.\h etc., complete as per specifications and drawings or as instructed from EIC. Inside size of 450 x 450 mm & depth not exceeding 500 mm complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Each | 8850.0 | 8850.0 | 4.0 | False | None | None | False | None | False | 35400.0 | 0 | 3331877 | 116760 | None | code238 | Construction of inspection chamber with 230 mm thick best quality masonary blocks in CM 1 : 4 laid over a bed of 150 mm thick PCC 1 : 4 : 8, walls plastered smooth, internal plastering 12 mm thk in CM 1 : 3 and external plastering 12 mm thick in CM 1 : 6 including finishing smooth inside surface of the chamber with cement rendering, curing etc. The quoted rate to include excavation in all types of soil, necessary wooden / steel form work, back filling of the chamber sides with the excavated soil, disposing of the surplus earth after back filling with initial lead of 30 metres or as directed, including, lift, benching and channelling shall be finished smooth, in PCC 1 : 2 : 4. Providing and fixing ofRCC Cover SFRC manhole frame and cover, set in PCC 1 : 2 : 4 with Thermo plastic moulded steps for chambers beyond 900 mm dept.\h etc., complete as per specifications and drawings or as instructed from EIC..Inside size of 600 x 600 mm & depth exceeding 450 Up to 750 mm complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Each | 13640.86 | 13640.86 | 12.0 | False | None | None | False | None | False | 163690.32 | 0 | 3331878 | 116760 | None | code239 | Construction of inspection chamber with 230 mm thick best quality masonary blocks in CM 1 : 4 laid over a bed of 150 mm thick PCC 1 : 4 : 8, walls plastered smooth, internal plastering 12 mm thk in CM 1 : 3 and external plastering 12 mm thick in CM 1 : 6 including finishing smooth inside surface of the chamber with cement rendering, curing etc. The quoted rate to include excavation in all types of soil, necessary wooden / steel form work, back filling of the chamber sides with the excavated soil, disposing of the surplus earth after back filling with initial lead of 30 metres or as directed, including, lift, benching and channelling shall be finished smooth, in PCC 1 : 2 : 4. Providing and fixing ofRCC Cover SFRC manhole frame and cover, set in PCC 1 : 2 : 4 with Thermo plastic moulded steps for chambers beyond 900 mm dept.\h etc., complete as per specifications and drawings or as instructed from EIC. Inside size of 900 x 900 mm & depth 751mm to 1200 mm, with PVC rungs. complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Each | 17926.03 | 17926.03 | 3.0 | False | None | None | False | None | False | 53778.09 | 0 | 3331879 | 116760 | None | code240 | Construction of RCC Machinehole chambers of 1:1.5:3 proportion or approved type Cast-insitu / Pre-cast RCC Machinehole chambers, constructed using form vibrators of standard type, with barricading, danger lighting and using of sight rails and boning rods wherever necessary, shoring and strutting wherever required using Ordinary Port Land Cement, using 1:1.5:3 proportion RCC with 20 mm and down graded jelly, well graded sand and steel of approved quality, 200 mm thick top concrete slab, having wall thickness and raft thickness as in approved drawings and with an offset in raft alround the chamber as in approved drawing, benching concrete with 1:6 slope towards the central drain finished smooth, including fixing and grouting of pipes, including conveying to work spot supply and fixing SFRC Machinehole cover and frame (Heavy duty) conforming to IS:12592 with latest amendments, on a bed of CC 1:2:4 Providing and fixing of minimum 3 mm thick encapsulated plastic footsteps (as per IS 10910) on 12 mm dia. Grade Fe-500 steel bar (as per IS 1786) staggered at 300 mm apart as detailed in Technical specifications, including stone grit beding wherever required, watering, curing, engraving Machinehole number with flow direction on the inner cylindrical surface etc., complete including cost of reinforcement steel and fabrication charges and also cost and conveyance of all materials, labour with all lead and lifts. The Pre-cast RCC Machinehole are for various diamters and depths as stated below and as per detailed drawings, specifications and direction of the Engineer. For 1.2m dia Machinehole etc., complete as per specifications and drawings or as instructed from EIC.Depth of 0.9m to1.2m(900dia).Constructing Pre-cast RCC Machinehole 1.2 m internal dia. , 1.0 M depth
& SFRC cover & frame.complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge. | Each | 51709.96 | 51709.96 | 3.0 | False | None | None | False | None | False | 155129.88 | 0 | 3331880 | 116760 | None | code241 | Construction of RCC Machinehole chambers of 1:1.5:3 proportion or approved type Cast-insitu / Pre-cast RCC Machinehole chambers, constructed using form vibrators of standard type, with barricading, danger lighting and using of sight rails and boning rods wherever necessary, shoring and strutting wherever required using Ordinary Port Land Cement, using 1:1.5:3 proportion RCC with 20 mm and down graded jelly, well graded sand and steel of approved quality, 200 mm thick top concrete slab, having wall thickness and raft thickness as in approved drawings and with an offset in raft alround the chamber as in approved drawing, benching concrete with 1:6 slope towards the central drain finished smooth, including fixing and grouting of pipes, including conveying to work spot supply and fixing SFRC Machinehole cover and frame (Heavy duty) conforming to IS:12592 with latest amendments, on a bed of CC 1:2:4 Providing and fixing of minimum 3 mm thick encapsulated plastic footsteps (as per IS 10910) on 12 mm dia. Grade Fe-500 steel bar (as per IS 1786) staggered at 300 mm apart as detailed in Technical specifications, including stone grit beding wherever required, watering, curing, engraving Machinehole number with flow direction on the inner cylindrical surface etc., complete including cost of reinforcement steel and fabrication charges and also cost and conveyance of all materials, labour with all lead and lifts. The Pre-cast RCC Machinehole are for various diamters and depths as stated below and as per detailed drawings, specifications and direction of the Engineer. For 1.2m dia Machinehole etc., complete as per specifications and drawings or as instructed from EIC.Depth of 0.9m to1.2m(900dia).Constructing Pre-cast RCC Machinehole 1.2 m internal dia. , 1.6 M depth
& SFRC cover & frame.complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge. | Each | 64550.72 | 64550.72 | 4.0 | False | None | None | False | None | False | 258202.88 | 0 | 3331881 | 116760 | None | code242 | Supplying, fixing and testing PVC Foam core SN 8 of approved make laid to the required level and making necessary connections inclusive of all specials like bends, tees, offsets, cleanouts, junctions, etc,.Complete. 160mm dia (IC to IC) complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Rmtr | 1534.0 | 1534.0 | 35.0 | False | None | None | False | None | False | 53690.0 | 0 | 3331882 | 116760 | None | code243 | Supplying, fixing and testing PVC Foam core SN 8 of approved make laid to the required level and making necessary connections inclusive of all specials like bends, tees, offsets, cleanouts, junctions, etc,.Complete. 200mm dia (IC to IC) complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Rmtr | 2150.55 | 2150.55 | 365.0 | False | None | None | False | None | False | 784950.75 | 0 | 3331883 | 116760 | None | code244 | Providing and laying Reinforced Cement Concrete pipe light duty NP2 for culverts, roadway utilities& crossingsas per IS 458:2003 in Single row including pointing ends and fixing collars with cement mortar 1:2 including cost of all materials, labour, curing completeas per specifications. (Provision for road crossings)., complete. 300 mm complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Rmtr | 1107.19 | 1107.19 | 130.0 | False | None | None | False | None | False | 143934.7 | 0 | 3331884 | 116760 | None | code245 | Supplying, installing, testing and commissioning of uPVC PERFORATED pipes and fitting conforming (6 kg/sqcm) conforming to IS 4985-2000, including cutting, cleaning and with solvent joints.
160mm diameter complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Rmtr | 236.0 | 236.0 | 125.0 | False | None | None | False | None | False | 29500.0 | 0 | 3331885 | 116760 | None | code246 | Construction of Sub soil well with Precast RCC Rings of clear dimensions as mentioned in the drawing with RCC top cover slab and RCC pre-cast manhole of 600mm x 600mm, valve chamber of 450mm x 450mm, inlet arrangements including excavation, curing with all leads and lifts,disposing the surplus earth with a lead of 300m. Sub soil well to be planned with PVC rungs of adequate spacing for going down and space for keeping pumps not less than 600 x 600 mm and complete or as instructed by EICcomplete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | No | 2360.0 | 2360.0 | 9.0 | False | None | None | False | None | False | 21240.0 | 0 | 3331886 | 116760 | None | code247 | Construction of catch basin of following size using 230 mm thick best quality masonary blocks in CM 1 : 4 laid over a bed of 150 mm thick PCC 1 : 4 : 8, walls plastered smooth, internal plastering 12mm thk in CM 1 : 3 and external plastering 12mm thick in CM 1 : 6 including finishing smooth inside surface of the chamber with cement rendering, curing etc. that can withstand upto 40 ton capacity. The quoted rate to include excavation in all types of soil, necessary wooden/steel form work, back filling of the chamber sides with the excavated soil, disposing of the surplus earth after back filling with initial lead of 30 metres or as directed, including lift. Providing and fixing of Precast RCC cover / RCC grating and cover, set in PCC 1 : 2 : 4. The top surface of the catch basin grating shall be flushed to the flooring level and making suitable outlet arrangement to lateral drain with necessary arrangements etc., complete as per specifications and drawings or as instructed from EIC 450 mm x 450 mm clear & Depth up to 600 mm - Precast cover of Light duty. 20 Ton complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | No | 5310.0 | 5310.0 | 4.0 | False | None | None | False | None | False | 21240.0 | 0 | 3331887 | 116760 | None | code248 | Construction of catch basin of following size using 230 mm thick best quality masonary blocks in CM 1 : 4 laid over a bed of 150 mm thick PCC 1 : 4 : 8, walls plastered smooth, internal plastering 12mm thk in CM 1 : 3 and external plastering 12mm thick in CM 1 : 6 including finishing smooth inside surface of the chamber with cement rendering, curing etc. that can withstand upto 40 ton capacity. The quoted rate to include excavation in all types of soil, necessary wooden/steel form work, back filling of the chamber sides with the excavated soil, disposing of the surplus earth after back filling with initial lead of 30 metres or as directed, including lift. Providing and fixing of Precast RCC cover / RCC grating and cover, set in PCC 1 : 2 : 4. The top surface of the catch basin grating shall be flushed to the flooring level and making suitable outlet arrangement to lateral drain with necessary arrangements etc., complete as per specifications and drawings or as instructed from EIC 600 mm x 600 mm clear & Depth up to 1000 mm - Precast cover of Medium duty. - 40 Ton complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | No | 14704.98 | 14704.98 | 11.0 | False | None | None | False | None | False | 161754.78 | 0 | 3331888 | 116760 | None | code249 | Construction of catch basin of following size using 230 mm thick best quality masonary blocks in CM 1 : 4 laid over a bed of 150 mm thick PCC 1 : 4 : 8, walls plastered smooth, internal plastering 12mm thk in CM 1 : 3 and external plastering 12mm thick in CM 1 : 6 including finishing smooth inside surface of the chamber with cement rendering, curing etc. that can withstand upto 40 ton capacity. The quoted rate to include excavation in all types of soil, necessary wooden/steel form work, back filling of the chamber sides with the excavated soil, disposing of the surplus earth after back filling with initial lead of 30 metres or as directed, including lift. Providing and fixing of Precast RCC cover / RCC grating and cover, set in PCC 1 : 2 : 4. The top surface of the catch basin grating shall be flushed to the flooring level and making suitable outlet arrangement to lateral drain with necessary arrangements etc., complete as per specifications and drawings or as instructed from EIC 900 mm x 900 mm clear & Depth up to 1200 mm - Precast cover of Medium duty. - 40 Ton complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | No | 16801.37 | 16801.37 | 11.0 | False | None | None | False | None | False | 184815.07 | 0 | 3331889 | 116760 | None | code250 | Construction of Reharge pit of 1.2m dia and 3.0m deep, brick wall with precast RCC rings covering the top with RCC slab including supply and fixing RCC MH cover and filter media . The quoted rate shall include earth work excavation, back filling, removing excess earth and making good the floor. 250mm bore with depth 20 m Filter Media Cost Dome type grating fixing on top etc.... Inserting 160 mm dia of 6kg/cm2 PVC perforated pipe and 12mm,20mm,40mm jelly and geofabric covering up to full length Approved make PVC pipe SWR grade "A" confirming to IS13592 The quoted rate shall include necessary ends,ballvalves,clamps,etc.,complete complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | No | 55755.0 | 55755.0 | 10.0 | False | None | None | False | None | False | 557550.0 | 0 | 3331890 | 116760 | None | code251 | Approved make 'Rainy Filter' F L- 500 Works on Cohesive Force & Centrifugal force. Operating Pressure is less than 2 feet of head. The outer Housing is made of High Density Polyehtylene. Efficiency of filter will be above 90 %. Source of power will be Gravity.for centrifugal force type with necessary accessories
Working Principle : Cohesive Force & Centrifugal force Operating Pressure: Less than 2 feet of head (0.060kg/cm2) Capacity: 480 LPM Filter Element: SS-304 Screen Mesh Size: 250 Microns Inlet: 110 MM Clean Water Outlet: 90 MM Drain Outlet: 110 MM Housing: High Density Polyethylene Efficiency of Filter: Above 90% Source of Power: Gravity , complete complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | No | 8260.0 | 8260.0 | 12.0 | False | None | None | False | None | False | 99120.0 | 0 | 3331891 | 116760 | None | code252 | EXTERNAL WATER SUPPLY SYSTEM:(BASEMENT CEILING LVL. & GROUND FLOOR ): Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for cold water supply including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. complete 25 mm dia complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Rmtr | 290.75 | 290.75 | 60.0 | False | None | None | False | None | False | 17445.0 | 0 | 3331892 | 116760 | None | code253 | Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for cold water supply including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 32 mm dia complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Rmtr | 353.06 | 353.06 | 15.0 | False | None | None | False | None | False | 5295.9 | 0 | 3331893 | 116760 | None | code254 | Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for cold water supply including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. complete 40 mm dia complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Rmtr | 394.59 | 394.59 | 25.0 | False | None | None | False | None | False | 9864.75 | 0 | 3331894 | 116760 | None | code255 | Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for cold water supply including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. complete. complete 50 mm dia complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Rmtr | 501.03 | 501.03 | 25.0 | False | None | None | False | None | False | 12525.75 | 0 | 3331895 | 116760 | None | code256 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.80 mm dia (Municipal Water supply). complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Rmtr | 2327.31 | 2327.31 | 25.0 | False | None | None | False | None | False | 58182.75 | 0 | 3331896 | 116760 | None | code257 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.100 mm dia (Tanker Water supply) complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Rmtr | 3276.15 | 3276.15 | 28.0 | False | None | None | False | None | False | 91732.2 | 0 | 3331897 | 116760 | None | code258 | Supplying, installing, testing and commissioning approved make cast brass body water meter with necessary unions for fixing on the inlet mains ; as shown on the drawing etc, complete with water meter chamber with cover and necessary ball valves, unions, etc complete 80 mm dia complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | No | 8068.84 | 8068.84 | 2.0 | False | None | None | False | None | False | 16137.68 | 0 | 3331898 | 116760 | None | code259 | Providing and constructing Valve Chamber comprising 230MM Thick burnt brick masonry walls built in CM 1:4 over CC bed ,DI cover slab benching in CC 1:2:4 internal faces plastered smooth in CM 1:4, 15mm thick and outside Rough Plastered with CM 1:6 15mm thick including 900x900mm medium earth work excavation returning and refilling and disposing surplus soil as directed by the Engineer in charge. 600 x 600 x 600 mm depthcomplete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | No | 10000.85 | 10000.85 | 8.0 | False | None | None | False | None | False | 80006.8 | 0 | 3331899 | 116760 | None | code260 | Providing and Fixing Copper Float valve, etc,confirming to I.S.I specifications of approved make as per directions complete.80 mm dia for BWSSB UG Sump complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | No | 3540.0 | 3540.0 | 2.0 | False | None | None | False | None | False | 7080.0 | 0 | 3331900 | 116760 | None | code261 | Supplying, laying, jointing, testing and commissioning approved make Agriculture pipes of 10 Kg/cm2 with solvent joints confirming to IS 5382 for exposed piping in Ceiling Lvl .The quoted rate shall include necessary fittings like Tees, 45 or 90 deg. Bends, Couplers, Offsets, etc., G.I. brackets with pvc coated GI clamps, nuts & bolts, anchor fasteners, grip bolts, GI threaded, rods, etc., complete. (External piping in Ceiling ). , as directed by Engineer-in-Charge. 110 mm dia(Waste & soil Pipe) & (Rain Water + FD) complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Rmtr | 326.57 | 326.57 | 171.0 | False | None | None | False | None | False | 55843.47 | 0 | 3331901 | 116760 | None | code262 | Supplying, laying, jointing, testing and commissioning approved make Agriculture pipes of 10 Kg/cm2 with Solvent joints confirming to IS 5382 for exposed piping in Ceiling .The quoted rate shall include necessary fittings like Tees, 45 or 90 deg. Bends, Couplers, Offsets, etc., G.I. brackets with pvc coated GI clamps, nuts & bolts, anchor fasteners, grip bolts, GI threaded, rods, etc., complete. (External piping in Ceiling Lvl.). , as directed by Engineer-in-Charge. 160 mm dia(Waste &soil Pipe) & (Rain Water pipe+Balcony pipe) complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Rmtr | 763.05 | 763.05 | 161.0 | False | None | None | False | None | False | 122851.05 | 0 | 3331902 | 116760 | None | code263 | Supplying, laying, jointing, testing and commissioning approved make Agriculture pipes of 10 Kg/cm2 with Solvent joints confirming to IS 5382 for exposed piping in Ceiling .The quoted rate shall include necessary fittings like Tees, 45 or 90 deg. Bends, Couplers, Offsets, etc., G.I. brackets with pvc coated GI clamps, nuts & bolts, anchor fasteners, grip bolts, GI threaded, rods, etc., complete. (External piping in Ceiling Lvl.). , as directed by Engineer-in-Charge. 75 mm dia(Balcony pipe + FD)complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Rmtr | 165.67 | 165.67 | 46.0 | False | None | None | False | None | False | 7620.82 | 0 | 3331903 | 116760 | None | code264 | BASEMENT DRAIN SYSTEM: Construction of catch basin of size mentioned below upto 600mm clear internal dimension for storm water with 230mm thick walls in well burnt table moulded bricks in CM 1:4 over a bed of 100 mm thick PCC 1:4:8 (M10) internal walls plastered smooth in CM 1:3 and external walls plastered in 1:3 with sponge finish. Fixing precast Heavy Duty RCC grating of size 550 x550mm on top surface flushed to the finished floor level with necessary excavation, back filling the selected excavated earth with all leads and lifts etc., complete. 600mm x 600mm x up tp 1200mm (clear internal dimension) complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | No | 8260.0 | 8260.0 | 3.0 | False | None | None | False | None | False | 24780.0 | 0 | 3331904 | 116760 | None | code265 | Supplying, laying, jointing, testing and commission-ing approved make SN 4 Foam core pipes confirming to IS 13592 with Solvent joints confirming to IS 5382. The quoted rate shall include necessary fittings like Tees, Bends, Offsets etc.,complete. 160 mm dia. complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Rmtr | 4956.0 | 4956.0 | 65.0 | False | None | None | False | None | False | 322140.0 | 0 | 3331905 | 116760 | None | code266 | Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Cum | 314.12 | 314.12 | 100.0 | False | None | None | False | None | False | 31412.0 | 0 | 3331906 | 116760 | None | code267 | SEWAGE TREATMENT PLANT:Waste water Treatment by Bio Sewage Treatment Plant (Bio STP) onsite construction [25 KLD and 50 KLD ]: Providing, installation and commissioning of anaerobic Bio Sewage
Treatment Plant (Bio STP) for black water with all necessary accessories such as pre- filter, pipes for the onsite constructed ABD tank as per the prescribed specification, according to the capacity, with a baffle wall to control the flow of water and to increase the retention time in the RCC ABD Tank. It includes an internal matrix for enhanced growth of bacteria, rising and falling pipes. For grey water, pre - filter, oil skimmer is provided along with an aerator. Post filter such as sand and carbon filter are also included as per the enclosed detailed technical specification attached as Annexure-2, including cost of material, loading and unloading and as directed by the engineer in charge etc., complete, including annual maintenance of the system for 5 years.
Note:
1. Above rates mentioned are for the preparation of estimate purpose only. All items are of ISI standards.
2. After commissioning of plant necessary testing to be done for the
3. Satisfaction of the Engineer in charge.
4. Design drawing of the system suitable for erection 50 KLD is given in figure for reference.Cap :80 KLD complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | No | 3003100.0 | 3003100.0 | 1.0 | False | None | None | False | None | False | 3003100.0 | 0 | 3331907 | 116760 | None | code268 | Interiors: Providing and constructing wooden partition of 100mm thick on aluminium framework, with 19mm thick ply and laminate of approved shade, on either side of the framework, and making provision for glazed window or opening wherever required, as per the detailed drawing. Cost to include cutting grooves, fasteners, adhesive, lead and lift etc., complete.( Without Block Work ) complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Sqm | 14893.96 | 14893.96 | 307.6 | False | None | None | False | None | False | 4581382.096 | 0 | 3331908 | 116760 | None | code269 | Partition made of 19mm ply with vision window panels made of 10mm toughened glass fixed to 35x35mm aluminium frame as per the detailed drawing. ( with Block Work )complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Sqm | 13695.08 | 13695.08 | 495.0 | False | None | None | False | None | False | 6779064.6 | 0 | 3331909 | 116760 | None | code270 | 12mm glazed partition with edge polished toughened glass fixed on to "Aluminium C Channel" on the floor and concealed beading at the top. 50 x 25mm size, 16 gauge aluminium sections framework placed at 2' 0" c/c both ways, extended to the nearest structural members (continuing up to slab level) and Covered with gypsum.Glazed Partition. complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Sqm | 14248.5 | 14248.5 | 102.0 | False | None | None | False | None | False | 1453347.0 | 0 | 3331910 | 116760 | None | code271 | 35 mm thick Flush door shutter(block board) with both side laminate(Greenlam-107 wool-Techno steel) ,Vision Panel-1200x150(8mm thk tempered glass) supported with Alumium frame work-horizontal and vertical member 18x100 with 40.08A door jamb, seal 3/B or G acoustic door seal as per manufacturers specification. The rate should be inclusive of all hardware Ozone/mortise lock OML 11A with 70mm cylinder ,Ozone/door handle OGH 55(25x1200)/PSS/SSS-H shape and Ozone/concealed door closer CDC 3800 ,10X10 mm metallic laminated groove around the door frame complete as per design and drawing.Make:Door-Greeply-Green club/Hardware-Ozone,Frame-Alloy complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Sqm | 5900.0 | 5900.0 | 174.0 | False | None | None | False | None | False | 1026600.0 | 0 | 3331911 | 116760 | None | code272 | Single leaf glass door made of 10mm thick tempered glass with all around Alumium beading, Partition system -aluminium horizontal and vertical member 18x100. The rate should be inclusive of all hardware Ozone upper patch bottom patch , Ozone make door handle OGH 55(25x1200)/PSS/SSS-H shape , Ozone make floor spring FS 8400, floor lock , strike plate & EP cylinder, 10X10 mm Alumium 'u' groove to be used as shadowline around the door frame etc complete as per design and drawing- Toughened glass door.complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Sqm | 14160.0 | 14160.0 | 54.72 | False | None | None | False | None | False | 774835.2 | 0 | 3331912 | 116760 | None | code273 | P/F of Single leaf Flush door shutter fixed on beech wood frame. Frame 50 x 75 mm section (seasoned, anti termite proof, treated with fire retardant,duco painted as/app). Door Shutter- 38 mm thick solid core Block board (Knot free wooden member, anti termite proof, treated with fire retardant) with approved laminated all both sides. Edges finished with wooden lipping match to laminate. Aluminium Extruded Air transfer Grill to be fixed at floor level as/design. Handle with Lock-Dorset ET-TDSC, Hinges-Dorset-5'long concealed SS finish..-Flush shutter wooden doors complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Sqm | 7080.0 | 7080.0 | 73.13 | False | None | None | False | None | False | 517760.4 | 0 | 3331913 | 116760 | None | code274 | Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 g/m2, both side inclusive) consisting of main ""T"" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross ""T"" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main ""T"" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross ""T"" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main ""T"" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GIadjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T- sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.12.5 mm thick square edge PVC Laminated Gypsum Tile of size 595x595 mm, madeof Gypsum plasterboard, manufactured from natural gypsum as per IS 2095 part I and laminated with white 0.16mm thick fire retardant PVC film on the face side and 12micron metalized polyester on the back side with all edges sealed with the face side PVC film which goes around and wraps the edges and is bonded to the edges and the back side metalized polyester film so as to make the tile a completely sealed unit.Ground Floor. complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Sqm | 2567.68 | 2567.68 | 3.0 | False | None | None | False | None | False | 7703.04 | 0 | 3331914 | 116760 | None | code275 | Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 g/m2, both side inclusive) consisting of main ""T"" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross ""T"" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main ""T"" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross ""T"" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main ""T"" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GIadjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T- sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.12.5 mm thick square edge PVC Laminated Gypsum Tile of size 595x595 mm, madeof Gypsum plasterboard, manufactured from natural gypsum as per IS 2095 part I and laminated with white 0.16mm thick fire retardant PVC film on the face side and 12micron metalized polyester on the back side with all edges sealed with the face side PVC film which goes around and wraps the edges and is bonded to the edges and the back side metalized polyester film so as to make the tile a completely sealed unit.First Floor. complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Sqm | 2593.36 | 2593.36 | 22.95 | False | None | None | False | None | False | 59517.612 | 0 | 3331915 | 116760 | None | code276 | Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 g/m2, both side inclusive) consisting of main ""T"" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross ""T"" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main ""T"" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross ""T"" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main ""T"" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GIadjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T- sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.12.5 mm thick square edge PVC Laminated Gypsum Tile of size 595x595 mm, madeof Gypsum plasterboard, manufactured from natural gypsum as per IS 2095 part I and laminated with white 0.16mm thick fire retardant PVC film on the face side and 12micron metalized polyester on the back side with all edges sealed with the face side PVC film which goes around and wraps the edges and is bonded to the edges and the back side metalized polyester film so as to make the tile a completely sealed unit.Second Floor. complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Sqm | 2619.29 | 2619.29 | 22.95 | False | None | None | False | None | False | 60112.7055 | 0 | 3331916 | 116760 | None | code277 | Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 g/m2, both side inclusive) consisting of main ""T"" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross ""T"" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main ""T"" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross ""T"" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main ""T"" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GIadjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T- sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.12.5 mm thick square edge PVC Laminated Gypsum Tile of size 595x595 mm, madeof Gypsum plasterboard, manufactured from natural gypsum as per IS 2095 part I and laminated with white 0.16mm thick fire retardant PVC film on the face side and 12micron metalized polyester on the back side with all edges sealed with the face side PVC film which goes around and wraps the edges and is bonded to the edges and the back side metalized polyester film so as to make the tile a completely sealed unit.Third Floor. complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Sqm | 2645.48 | 2645.48 | 22.95 | False | None | None | False | None | False | 60713.766 | 0 | 3331917 | 116760 | None | code278 | Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 g/m2, both side inclusive) consisting of main ""T"" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross ""T"" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main ""T"" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross ""T"" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main ""T"" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GIadjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T- sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.12.5 mm thick square edge PVC Laminated Gypsum Tile of size 595x595 mm, madeof Gypsum plasterboard, manufactured from natural gypsum as per IS 2095 part I and laminated with white 0.16mm thick fire retardant PVC film on the face side and 12micron metalized polyester on the back side with all edges sealed with the face side PVC film which goes around and wraps the edges and is bonded to the edges and the back side metalized polyester film so as to make the tile a completely sealed unit.Fourth Floor. complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Sqm | 2671.94 | 2671.94 | 22.95 | False | None | None | False | None | False | 61321.023 | 0 | 3331918 | 116760 | None | code279 | Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 g/m2, both side inclusive) consisting of main ""T"" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross ""T"" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main ""T"" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross ""T"" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main ""T"" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GIadjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T- sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.12.5 mm thick square edge PVC Laminated Gypsum Tile of size 595x595 mm, madeof Gypsum plasterboard, manufactured from natural gypsum as per IS 2095 part I and laminated with white 0.16mm thick fire retardant PVC film on the face side and 12micron metalized polyester on the back side with all edges sealed with the face side PVC film which goes around and wraps the edges and is bonded to the edges and the back side metalized polyester film so as to make the tile a completely sealed unit.Fifth Floor. complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Sqm | 2698.66 | 2698.66 | 22.95 | False | None | None | False | None | False | 61934.247 | 0 | 3331919 | 116760 | None | code280 | Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 g/m2, both side inclusive) consisting of main ""T"" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross ""T"" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main ""T"" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross ""T"" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main ""T"" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GIadjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T- sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.12.5 mm thick square edge PVC Laminated Gypsum Tile of size 595x595 mm, madeof Gypsum plasterboard, manufactured from natural gypsum as per IS 2095 part I and laminated with white 0.16mm thick fire retardant PVC film on the face side and 12micron metalized polyester on the back side with all edges sealed with the face side PVC film which goes around and wraps the edges and is bonded to the edges and the back side metalized polyester film so as to make the tile a completely sealed unit.Sixth Floor. complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Sqm | 2725.64 | 2725.64 | 22.95 | False | None | None | False | None | False | 62553.438 | 0 | 3331920 | 116760 | None | code281 | Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per m2 including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross “T” of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main’T’ at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross ‘T’ of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel size(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230 mm interval and laying 15 mm thick densified edges calicum silicate ceiling tiles of approved texture in the grid, including, cutting/
making opening for services like diffusers, grills, light fittings, fixtures,smoke detectors etc., wherever required. Main ‘T’ runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main ‘T’, bottom exposed with 24 mm of all T sections shall be pre-painted with polyster baked paint, for all heights,as per specifications, drawings and as directed by Engineer-in-Charge. First Floor. complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Sqm | 2219.49 | 2219.49 | 177.54 | False | None | None | False | None | False | 394048.2546 | 0 | 3331921 | 116760 | None | code282 | Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per m2 including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross “T” of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main’T’ at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross ‘T’ of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel size(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230 mm interval and laying 15 mm thick densified edges calicum silicate ceiling tiles of approved texture in the grid, including, cutting/
making opening for services like diffusers, grills, light fittings, fixtures,smoke detectors etc., wherever required. Main ‘T’ runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main ‘T’, bottom exposed with 24 mm of all T sections shall be pre-painted with polyster baked paint, for all heights,as per specifications, drawings and as directed by Engineer-in-Charge. Second Floor. complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Sqm | 2241.46 | 2241.46 | 239.81 | False | None | None | False | None | False | 537524.5226 | 0 | 3331922 | 116760 | None | code283 | Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per m2 including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross “T” of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main’T’ at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross ‘T’ of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel size(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230 mm interval and laying 15 mm thick densified edges calicum silicate ceiling tiles of approved texture in the grid, including, cutting/
making opening for services like diffusers, grills, light fittings, fixtures,smoke detectors etc., wherever required. Main ‘T’ runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main ‘T’, bottom exposed with 24 mm of all T sections shall be pre-painted with polyster baked paint, for all heights,as per specifications, drawings and as directed by Engineer-in-Charge. Third Floor. complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Sqm | 2263.44 | 2263.44 | 46.09 | False | None | None | False | None | False | 104321.9496 | 0 | 3331923 | 116760 | None | code284 | Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per m2 including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross “T” of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main’T’ at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross ‘T’ of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel size(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230 mm interval and laying 15 mm thick densified edges calicum silicate ceiling tiles of approved texture in the grid, including, cutting/
making opening for services like diffusers, grills, light fittings, fixtures,smoke detectors etc., wherever required. Main ‘T’ runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main ‘T’, bottom exposed with 24 mm of all T sections shall be pre-painted with polyster baked paint, for all heights,as per specifications, drawings and as directed by Engineer-in-Charge. Fourth Floor. complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Sqm | 2285.41 | 2285.41 | 289.28 | False | None | None | False | None | False | 661123.4048 | 0 | 3331924 | 116760 | None | code285 | Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per m2 including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross “T” of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main’T’ at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross ‘T’ of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel size(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230 mm interval and laying 15 mm thick densified edges calicum silicate ceiling tiles of approved texture in the grid, including, cutting/
making opening for services like diffusers, grills, light fittings, fixtures,smoke detectors etc., wherever required. Main ‘T’ runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main ‘T’, bottom exposed with 24 mm of all T sections shall be pre-painted with polyster baked paint, for all heights,as per specifications, drawings and as directed by Engineer-in-Charge. Fifth Floor. complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Sqm | 2307.39 | 2307.39 | 189.33 | False | None | None | False | None | False | 436858.1487 | 0 | 3331925 | 116760 | None | code286 | Providing and fixing in position 12mm thick plaster of paris (Gypsum anhydrous) for ceiling reinforced with hessian cloth flat surface with ceiling tiles up to a height of 5 m above floor level over aluminium strips 25mm x 6mm and rendered smooth with plaster of paris including cost of materials, labour, curing complete as per specifications- Gypsum Board.Ground Floor ( Record Room Corridor and Entrance Lobby ) complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Sqm | 1521.02 | 1521.02 | 203.78 | False | None | None | False | None | False | 309953.4556 | 0 | 3331926 | 116760 | None | code287 | Providing and fixing in position 12mm thick plaster of paris (Gypsum anhydrous) for ceiling reinforced with hessian cloth flat surface with ceiling tiles up to a height of 5 m above floor level over aluminium strips 25mm x 6mm and rendered smooth with plaster of paris including cost of materials, labour, curing complete as per specifications- Gypsum Board.First Floor ( Meeting Room , Work station area, Talisdhar cum Ante Room, PA Cabin, AC, Ante Room, DC, Ante Room, Waiting Lounge PA to DC, All Cabin Toilets , Lift Lobby) complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Sqm | 1536.23 | 1536.23 | 448.09 | False | None | None | False | None | False | 688369.3007 | 0 | 3331927 | 116760 | None | code288 | Providing and fixing in position 12mm thick plaster of paris (Gypsum anhydrous) for ceiling reinforced with hessian cloth flat surface with ceiling tiles up to a height of 5 m above floor level over aluminium strips 25mm x 6mm and rendered smooth with plaster of paris including cost of materials, labour, curing complete as per specifications- Gypsum Board.Second Floor ( Workstation, Lift Lobby, JD Cabin, Ante room, Asst. JD , Secretary Cabins, Ante Rooms, Asst. Secretart Cabin, Admin Head, Meeting Room and all cabin toilets ) complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Sqm | 1551.44 | 1551.44 | 373.89 | False | None | None | False | None | False | 580067.9016 | 0 | 3331928 | 116760 | None | code289 | Providing and fixing in position 12mm thick plaster of paris (Gypsum anhydrous) for ceiling reinforced with hessian cloth flat surface with ceiling tiles up to a height of 5 m above floor level over aluminium strips 25mm x 6mm and rendered smooth with plaster of paris including cost of materials, labour, curing complete as per specifications- Gypsum Board.Third Floor ( Board Room. Lift Lobby, Pantry, all corridors, workstation, Legal Advisor, Ante Room , Law Officer, PA to CEO , CEO's Ante Room,Waiting Lounge, All cabin Toilets) complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Sqm | 1566.65 | 1566.65 | 489.72 | False | None | None | False | None | False | 767219.838 | 0 | 3331929 | 116760 | None | code290 | Providing and fixing in position 12mm thick plaster of paris (Gypsum anhydrous) for ceiling reinforced with hessian cloth flat surface with ceiling tiles up to a height of 5 m above floor level over aluminium strips 25mm x 6mm and rendered smooth with plaster of paris including cost of materials, labour, curing complete as per specifications- Gypsum Board.Fourth Floor ( Lift Lobbies, Asst. Secreatry, Internal Audit, AS Audit Cabin, FA, COF, Ante Room, AO, Cash Section, Work station, All cabin Toilets ) complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Sqm | 1581.86 | 1581.86 | 367.02 | False | None | None | False | None | False | 580574.2572 | 0 | 3331930 | 116760 | None | code291 | Providing and fixing in position 12mm thick plaster of paris (Gypsum anhydrous) for ceiling reinforced with hessian cloth flat surface with ceiling tiles up to a height of 5 m above floor level over aluminium strips 25mm x 6mm and rendered smooth with plaster of paris including cost of materials, labour, curing complete as per specifications- Gypsum Board.Fifth Floor ( Lift Lobbies, TA, ACDO, ante room, CE-1 's waiting Lounge, Ante room and CE-1's Assistants , CE-2's Ante Room, JDTP, DDTP, EO, Workstation Area, Cabin Toilets ) complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Sqm | 1597.07 | 1597.07 | 348.11 | False | None | None | False | None | False | 555956.0377 | 0 | 3331931 | 116760 | None | code292 | Providing and fixing in position 12mm thick plaster of paris (Gypsum anhydrous) for ceiling reinforced with hessian cloth flat surface with ceiling tiles up to a height of 5 m above floor level over aluminium strips 25mm x 6mm and rendered smooth with plaster of paris including cost of materials, labour, curing complete as per specifications- Gypsum Board.Sixth Floor ( Lift Lobbies, TA, ACDO, ante room, CE-1 's waiting Lounge, Ante room and CE-1's Assistants , CE-2's Ante Room, JDTP, DDTP, EO, Workstation Area, Cabin Toilets ) complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Sqm | 1612.28 | 1612.28 | 320.38 | False | None | None | False | None | False | 516542.2664 | 0 | 3331932 | 116760 | None | code293 | Providing and fixing 22mm thk PVC fluted panels of 5” width and 25*25mm grooves of approved colour to the aluminium framework. Rate to include all necessary fasterners, tools and equipment-PVC Fluted panel ceiling complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Sqm | 6372.0 | 6372.0 | 162.61 | False | None | None | False | None | False | 1036150.92 | 0 | 3331933 | 116760 | None | code294 | Providing and laying Wooden Laminated flooring of approved size, color and make.Providing and fixing homogeneous 2mm thick WOODEN LAMINATE and in approved pattern, colour and shade on a smooth finished base using rubber based adhesives of approved quality and manufacturer like Dunlop S-758, Fevicol SR 998 or equivalent including rolling with light wooden roller weighing about 5 kg. all complete as directed by Engineer-in-Charge.Same as B.1 but for skirting with mm thick WOODEN LAMINATE of 100mm high using rubber based adhesives of approved quality and manufacturer like Dunlop S-758, Fevicol SR 998 or equivalent including rolling with light wooden roller weighing about 5 kg. all complete as directed by Engineer-in-Charge- Laminated wooden flooring.Fourth Floor ( CoF Chamber and Ante Room ) & Fifth Floor ( CE-1, CE-2 Chamber including Waiting Lounge and meeting room ) complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Sqm | 2950.0 | 2950.0 | 155.0 | False | None | None | False | None | False | 457250.0 | 0 | 3331934 | 116760 | None | code295 | Providing & fixing Roller blinds of reputed make 38mm round Aluminium channel with approved fabric, telting with chain (Ball) system with all necessary fittings and fixtures as per direction of Engineer in charge. complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Sqm | 2336.4 | 2336.4 | 290.0 | False | None | None | False | None | False | 677556.0 | 0 | 3331935 | 116760 | None | code296 | Providing and fixing in position 6mm thick edge polished, toughened glass panels to the existing back partition/ Masonry wall / laminate finished surface in horizontal plane with necessary 2mm thick Aluminium trims as per the detailed drawings. 100% of glass surface shall be fixed with 3M vinyl film as per the detailed drawings.Glass Panelling for Writing Board in board rooms and conference rooms complete with all lead and lift etc, as per specification , Suitable design and as per directed by the Engineer in Charge | Sqm | 5841.0 | 5841.0 | 120.0 | False | None | None | False | None | False | 700920.0 | 0 | 3331936 | 116760 | None | code297 | Providing and fixing flawless 6mm thick mirror of approved quality with necessary bevelling as per the detail drawing. The mirror shall be fixed on 12mm thk plywood backing with stainless steel studs/ stainless steel "L" running clips/3M double sided tape as per detail drawings. - Mirror Panelling For Toilets in GF + 5 UF + Sixth Floor complete with all lead and lift etc, as per specification,Suitable design and as per directed by the Engineer in Charge | Sqm | 4130.0 | 4130.0 | 46.0 | False | None | None | False | None | False | 189980.0 | 0 | 3331937 | 116760 | None | code298 | Providing, fabricating and fixing of above counter storage with T slot anodised Matt 45mm thk aluminium frame sections as frame work and with unit of size 350mm deep x 600mm height, carcass, shelves & shutters formed out of 6mm thk plain frosted glass finish, storage to have SS handles and each set of shutter shall have 2 spring loaded hinges zero crank as per the size of shutter, with EG SS finish locks, 2 nos. heavy SS ball catch, C-Type SS 8mm dia x 96mm handles complete as per drawings and details. Under Granite counter in Pantry,Overhead storage in Pantry. complete with all lead and lift etc, as per specification,Suitable design and as per directed by the Engineer in Charge | Sqm | 27942.4 | 27942.4 | 30.0 | False | None | None | False | None | False | 838272.0 | 0 | 3331938 | 116760 | None | code299 | Providing and fixing the laminate panelling on framework made in 50 x 25/ 50.8 x 25.4mm, 16swg (1.626mm thick and consider the tolerance range of 1.60 to1.65mm) aluminium tube section framework. The aluminium sections shall be placed at 2' 0" c/c both ways and rigidly connected together using 3mm thick aluminium L- cleats fixed/ fastened to aluminium section with double screws as per the detail drawings and Architects' instructions. The framework shall be cladded with 12mm thick plywood and finished in 1.5mm thick laminate to pattern as per the detail drawings all complete as per drawing, specifications and as directed by the Engineer in charge. Cladding. complete with all lead and lift etc, as per specification,Suitable design and as per directed by the Engineer in Charge | Sqm | 11800.0 | 11800.0 | 41.0 | False | None | None | False | None | False | 483800.0 | 0 | 3331939 | 116760 | None | code300 | Installation of Low height storage units of size mentioned below made 19mm thick plywood as per the detail drawings. The storage unit shall have open able shutters made of 19mm thick plywood finished in approved shade of laminate as per manufacturers specifications. All the exposed ply edges shall have a matching imported rigid PVC lipping as per the manufacturers specification. This also includes providing and fixing of hardware like locks, handles, spring loaded hinges etc. as approved by the Architects. This also includes providing one master key for each of the storage units complete with all lead and lift etc, as per specification,Suitable design and as per directed by the Engineer in Charge | Sqm | 19045.2 | 19045.2 | 670.2 | False | None | None | False | None | False | 12764093.04 | 0 | 3331940 | 116760 | None | code301 | Providing and fixing laminated ply lockable full height storage of overall size as per the detail given in drawing. The basic structure shall be made of 19mm thick BWP ply with required framing and finished with laminate and 2mm thick rigid PVC edge lipping as directed by the Architects. This also includes providing necessary iron mongeries, provision for services all complete as per drawing, specifications and as directed by the Engineer in charge complete with all lead and lift etc, as per specification,Suitable design and as per directed by the Engineer in Charge | Sqm | 19045.2 | 19045.2 | 175.0 | False | None | None | False | None | False | 3332910.0 | 0 | 3331941 | 116760 | None | code302 | Supply and installation of tile base modular workstations with 1200mm high partitions supported on heavy duty levelers with two race ways i.e. one at the skirting level and another above the worktop as per detail drawing. The partitions shall be of 75mm thick and with worktop of 600 mm deep clear finished to shape as per design in laminate. The edges of the worktop shall be finished with matching imported rigid PVC lipping to the profile as per the detail drawings. The partition panels shall have the all modules finished in fabric from both the sides with 3mm foam backing with grooves and joints as indicated in the detail drawings. The internal surface of partition panels above the worktop shall have one writing board, and balance with magnetic tack/ pin up board as per the detail drawings. This also includes providing atleast 15 nos of magnets per workstation of approved make per the detail drawings. The aluminium powder coated raceways shall be recessed with necessary machine cut, properly filed opening to accommodate enough numbers of switches and sockets of Raw Power / UPS / Data / Voice etc as per the detail drawings. All the exposed partition panel edges shall be fixed with aluminium powder coated trims made to profile as per the detail drawings. The shade, make of fabric, laminate, metal components and accessories shall be approved by the Architects. The fabric to be considered shall be from the Manufacturers standard range Catalogues. This includes providing necessary cable tray per workstation supported on partitions panels to hold loose cable under worktops with enough numbers of MS powder coated Wire managers as per the detail drawings. This also includes providing and fixing in position each workstation with 1 no MS powder coated/ PVC key board tray.complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Nos | 21240.0 | 21240.0 | 120.0 | False | None | None | False | None | False | 2548800.0 | 0 | 3331942 | 116760 | None | code303 | Providing & fixing of Tea table 900mm x 750mm 450mm with 12mm thick ethched tempered glass with bevelled drawing made out of BWP ply and out faces laminated with 4mm thick veneer or 1mm thick laminate.
Centre Table complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | No | 9735.0 | 9735.0 | 11.0 | False | None | None | False | None | False | 107085.0 | 0 | 3331943 | 116760 | None | code304 | Providing & fixing of Tea table 900mm x 750mm 450mm with 12mm thick ethched tempered glass with bevelled drawing made out of BWP ply and out faces laminated with 4mm thick veneer or 1mm thick laminate.Side tables complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | No | 1770.0 | 1770.0 | 120.0 | False | None | None | False | None | False | 212400.0 | 0 | 3331944 | 116760 | None | code305 | Providing & fixing of Tea table 900mm x 750mm 450mm with 12mm thick ethched tempered glass with bevelled drawing made out of BWP ply and out faces laminated with 4mm thick veneer or 1mm thick laminate. Dining table in Ante room complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | No | 2360.0 | 2360.0 | 7.0 | False | None | None | False | None | False | 16520.0 | 0 | 3331945 | 116760 | None | code306 | Providing & fixing of Tea table 900mm x 750mm 450mm with 12mm thick ethched tempered glass with bevelled drawing made out of BWP ply and out faces laminated with 4mm thick veneer or 1mm thick laminate.Security desk complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | No | 11800.0 | 11800.0 | 6.0 | False | None | None | False | None | False | 70800.0 | 0 | 3331946 | 116760 | None | code307 | Providing & fixing of Tea table 900mm x 750mm 450mm with 12mm thick ethched tempered glass with bevelled drawing made out of BWP ply and out faces laminated with 4mm thick veneer or 1mm thick laminate.Reception table complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | No | 59000.0 | 59000.0 | 1.0 | False | None | None | False | None | False | 59000.0 | 0 | 3331947 | 116760 | None | code308 | Supply and installation tables of overall size and shape as per detail drawing with top made of 25mm thick Particle board / MDF and finished in laminate of approved shade . The table top should have provision for fixing Raw Power/ UPS/ Data and Voice switches and sockets with necessary cabling as per the manufacturers specifications, The switches/ sockets and data points should be concealed within the table top and should be accessable by way of a flip top or alternate mechanisim as followed by the manufacturer adhering to the clients requirements. All the edges of the table and modesty panels shall be finished with matching imported rigid PVC lipping to manufacturers specifications.The table shall be provided with enough numbers of MS powder coated wire managers as per the detail drawings. Production of the table shall be started only on approval of shop drawing submitted by the vendor.Top Cadre Cabin tables. complete with all lead and lift etc, as per specification,Suitable design and as per directed by the Engineer in Charge | No | 17700.0 | 17700.0 | 7.0 | False | None | None | False | None | False | 123900.0 | 0 | 3331948 | 116760 | None | code309 | Supply and installation tables of overall size and shape as per detail drawing with top made of 25mm thick Particle board / MDF and finished in laminate of approved shade . The table top should have provision for fixing Raw Power/ UPS/ Data and Voice switches and sockets with necessary cabling as per the manufacturers specifications, The switches/ sockets and data points should be concealed within the table top and should be accessable by way of a flip top or alternate mechanisim as followed by the manufacturer adhering to the clients requirements. All the edges of the table and modesty panels shall be finished with matching imported rigid PVC lipping to manufacturers specifications.The table shall be provided with enough numbers of MS powder coated wire managers as per the detail drawings. Production of the table shall be started only on approval of shop drawing submitted by the vendor.Other Cabin tables. complete with all lead and lift etc, as per specification,Suitable design and as per directed by the Engineer in Charge | No | 11800.0 | 11800.0 | 18.0 | False | None | None | False | None | False | 212400.0 | 0 | 3331949 | 116760 | None | code310 | Supply and installation tables of overall size and shape as per detail drawing with top made of 25mm thick Particle board / MDF and finished in laminate of approved shade . The table top should have provision for fixing Raw Power/ UPS/ Data and Voice switches and sockets with necessary cabling as per the manufacturers specifications, The switches/ sockets and data points should be concealed within the table top and should be accessable by way of a flip top or alternate mechanisim as followed by the manufacturer adhering to the clients requirements. All the edges of the table and modesty panels shall be finished with matching imported rigid PVC lipping to manufacturers specifications.The table shall be provided with enough numbers of MS powder coated wire managers as per the detail drawings. Production of the table shall be started only on approval of shop drawing submitted by the vendor.Board room tables. complete with all lead and lift etc, as per specification,Suitable design and as per directed by the Engineer in Charge | No | 29500.0 | 29500.0 | 1.0 | False | None | None | False | None | False | 29500.0 | 0 | 3331950 | 116760 | None | code311 | Supply and installation tables of overall size and shape as per detail drawing with top made of 25mm thick Particle board / MDF and finished in laminate of approved shade . The table top should have provision for fixing Raw Power/ UPS/ Data and Voice switches and sockets with necessary cabling as per the manufacturers specifications, The switches/ sockets and data points should be concealed within the table top and should be accessable by way of a flip top or alternate mechanisim as followed by the manufacturer adhering to the clients requirements. All the edges of the table and modesty panels shall be finished with matching imported rigid PVC lipping to manufacturers specifications.The table shall be provided with enough numbers of MS powder coated wire managers as per the detail drawings. Production of the table shall be started only on approval of shop drawing submitted by the vendor.Meeting room tables. complete with all lead and lift etc, as per specification,Suitable design and as per directed by the Engineer in Charge | No | 23600.0 | 23600.0 | 10.0 | False | None | None | False | None | False | 236000.0 | 0 | 3331951 | 116760 | None | code312 | Top cadre chairs - Installation of chair with following specification.1.Headrest: Height adjustment; 2.Backrest: black nylon with fiber frame, flexible plastic K-resin lumbar; 3.Armrest: 3DAdjustable black PU armpad ARMREST; 4.Seat and back cover: Korea black nylon Mesh back+black double nylon mesh seat . 5.High mechanism with adjustable seat up-down and 4 level 135deg back tilt-angle control and sliding function; 6.Gas spring: Class 3; 7.Base:Aluminum base. 8. Add the front mould foam complete with all lead and lift etc, as per specification,Suitable design and as per directed by the Engineer in Charge | No | 23600.0 | 23600.0 | 7.0 | False | None | None | False | None | False | 165200.0 | 0 | 3331952 | 116760 | None | code313 | cabin chairs: Installation of Mid back chair with adjustable arm rest Medium Mesh Back Chair, Synchro Mechanism With inbuilt Lumbar Support & Adjustable Arms with Nylon Base and Nylon castors complete with all lead and lift etc, as per specification,Suitable design and as per directed by the Engineer in Charge | No | 17700.0 | 17700.0 | 18.0 | False | None | None | False | None | False | 318600.0 | 0 | 3331953 | 116760 | None | code314 | Installation ofchair with following specification
1.Backrest: new white PA66 with fiber frame 2.Armrest:1D Adjustable black PU armpad ARMREST ; 3.Seat and back cover: black mesh back+black fabric seat with mould foam; (The colour and quantity for the same shall be confirmed after getting the shop drawing). 4.Simple mechanism with adjustable seat up-down and 135deg back tilt-angle control function; 5.Gas spring: Class 3; 6.Base:Aluminum base Work station chairs, Visitors and Reception Areas complete with all lead and lift etc, as per specification,Suitable design and as per directed by the Engineer in Charge | No | 5900.0 | 5900.0 | 134.0 | False | None | None | False | None | False | 790600.0 | 0 | 3331954 | 116760 | None | code315 | Installation of Imported half cowhide, wear-resistant, soft and resilient. With lifting and pitching chassis&aluminum alloy five-star wheel foot. Durable Material: Inner Material: Using Hong Kong Ultra High Density Sponge as the base material, which is of high rebound resilience&hard to deform Board room chairs complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | No | 9440.0 | 9440.0 | 50.0 | False | None | None | False | None | False | 472000.0 | 0 | 3331955 | 116760 | None | code316 | Chairs: PP Type with SS Legs. Cafeteria & Multipurpose Hall Chairs complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | No | 1770.0 | 1770.0 | 200.0 | False | None | None | False | None | False | 354000.0 | 0 | 3331956 | 116760 | None | code317 | 1 BAY OPTIMIZER PUSH PULL TYPE (1200W, 400D,1980H)
Overall Dimensions of SD - 2 Single Drive Cover Unit 1Bay (U/C + Fittings + Cover) shall be 2400mm(W)x400mm(D)x2121.5mm(H).
The Construction shall be rigid knock down made out of 0.8 thick CRCA steel conforming to IS: 513. Epoxy polyester powder coated finish thickness of 40 microns. Shelf construction shall be made from CRCA steel 0.8 mm thick IS:513. Uniformly distributed load capacity of 100 Kg. Undercarriage shall have construction in welded frame made of HR sheet 3 mm thick conforming to IS: 2062. The roller assembly comprises of a die-cast step wheel, 2 deep-groove ball bearings and a MS shaft. The step wheel is made of cast steel and is fitted onto the MS shaft using a feather key. The two ball bearings are then fastened on either side of the step wheel using circlips. This entire roller assembly is then snap-fitted into a wheel housing. The wheel housing is fixed in the ”U” channel of the under structure using machine screws. This wheel-housing is made of engineering plastic material made by injection-moulding process. The entire roller assembly is designed to withstand the maximum loads of the body. Fittings shall be centralized locking arrangement through locking stiffener mounted onto back of single last unit so that it gets locked on channels when all the units are brought together. The Recess handle lock shall be of approved make placed at suitable height. The nuts & bolts are galvanized / blackodized / Zn Plated. Finish -The bodies including shelves are given antirust surface treatment & are coated with epoxy polyester powder of approved color and shade with dry film thickness of min 40 microns. The testing of paint is done for various physical & chemical properties as per IS: 101. Label holder at front cover of body of aluminium extrusion of length 396mm for SD. Over that a transparent plastic of corresponding length of 150-200 micron polythene is to be inserted. Hinge Doors & Locking: Hinge Doors shall be made of 0.8thick CRCA steel confirming to IS: 513 Grade D. Hinged door provided in each unit have recessed Die cast Handle cum lock with 3 way locking through a lever & shooting bolts.
File Separator: File separators 2 nos. made of 2mm thick. CRCA sheet (IS:513) shall be provided.excluding Hinged doors, file separators cost
complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Unit | 178321.6 | 178321.6 | 1.0 | False | None | None | False | None | False | 178321.6 | 0 | 3331957 | 116760 | None | code318 | 2BAY OPTIMIZER PLUS-DRIVE TYPE (1200W, 400D,1980H) (a)Overall Dimensions of SD-2 Single Drive Cover Unit 2 Bay(U/C plus Fittings plus Cover) shall be 2400mm(W)x400mm (D)x2121.5mm(H). The Construction shall be rigid knock down made out of 0.8 thick CRCA steel conforming to IS:513. Epoxy polyester powder coated finish thickness of 40microns. Shelf construction shall be made from CRCA steel 0.8mm thick IS:513.Uniformly distributed load capacity of 100Kg. Undercarriage shall have construction in welded frame made of HR sheet 3mm thick conforming to IS:2062. The Movements shall be Drive Type configuration:In case of D2, movement of units is achieved mechanically through a PU Drive Wheel & Sprocket-Chain Tensioner arrangement mounted rigidly onto body size. For D2 each movable undercarriage shall be provided with 2 rollers on the shaft for driving, 2 antifriction ball bearing for rolling.The roller assembly comprises of a die-cast step wheel, 2 deep-groove ball bearings and MS shaft. The step wheel is made of cast steel & is fitted onto the MS shaft using a feather key. The two ball bearings are then fastened on either side of the step wheel using circlips. This entire roller assembly is then snap-fitted into a wheel housing. The wheel housing is fixed in the U channel of the understructure using machine screws. This wheel-housing is made of engineering plastic material made by injection moulding process. The entire roller assembly is designed to withstand the maximum loads of the body. Fittings shall be centralized locking arrangement through locking stiffener mounted onto back of single last unit so that it gets locked on channels when all the units are brought together. The Recess handle lock shall be of approved make placed at suitable height.The sprocket-chain arrangement is covered by a 1mm thick. CRCA sheet Drive Unit Cover with dimensions 1202mmx398mmx87mm and is fixed onto the side of the body. The PU handwheel is rigidly fixed at suitable height on side of the body & projects out of cover by another 99mm When the last unit is twin movable, hinged doors as accessories are provided for the end bodies, so in this case locking stiffener is mounted onto drive unit cover. Each Drive Type units shall have Locking Knob near the drive wheel for manual locking of individual units when a person is using those units. Knob shall be rotated to unlock position when units are to be moved. End stoppers shall be provided to prevent derailment.The nuts & bolts are galvanized/blackodized /Zn Plated. Also total no. of loading levels per under structure shall be 10 for SD2.Finish. The bodies including shelves are given antirust surface treatment & are coated with epoxy polyester powder of approved color & shade with dry film thickness of min40 microns. The testing of paint is done for various physical & chemical properties as per IS:101. Label holder at front cover of body of aluminium extrusion of length 396mm for SD. Over that a transparent plastic of corresponding length of 150-200micron polythene is to be inserted. It consists of ‘C’ section 2mm thick HR sheet & Square 25.4mmx2mm thick ERW tube both connected by screws. Hinge Doors & Locking: Hinge Doors shall be made of 0.8thick CRCA steel confirming to IS:513 Grade D. Hinged door provided in each unit have recessed Die cast Handle cum lock with 3 way locking through a lever & shooting bolts. File Separator: File separators 2nos. made of 2mm thick. CRCA sheet (IS:513) shall be provided (b) Same as above with Overall Dimensions of LD-2 Single last Drive Unit 2 Bay(U/C plus Fittings plus Cover) shall be 2400mm (W) x 400mm(D)x2121.5mm(H).(c) Same as above with Overall Dimensions of TD-2 Twin Mobile Drive Unit 2Bay(U/C plus Fittings plus Cover) shall be 2400mm (W)x800mm(D)x2121.5mm(H) for Record Room-1(10.225mx3.95m) & fourth floor-2 Bay 1SD 2TD 1LD, excluding Hinged doors, file separators cost complete with all lead & lift etc, as per specification & as per directed by the Engineer in Charge. | Unit | 530451.3 | 530451.3 | 2.0 | False | None | None | False | None | False | 1060902.6 | 0 | 3331958 | 116760 | None | code319 | 2BAY OPTIMIZER PLUS-DRIVE TYPE (1200W, 400D,1980H) (a)Overall Dimensions of SD-2 Single Drive Cover Unit 2 Bay(U/C plus Fittings plus Cover) shall be 2400mm(W)x400mm (D)x2121.5mm(H). The Construction shall be rigid knock down made out of 0.8 thick CRCA steel conforming to IS:513. Epoxy polyester powder coated finish thickness of 40microns. Shelf construction shall be made from CRCA steel 0.8mm thick IS:513.Uniformly distributed load capacity of 100Kg. Undercarriage shall have construction in welded frame made of HR sheet 3mm thick conforming to IS:2062. The Movements shall be Drive Type configuration:In case of D2, movement of units is achieved mechanically through a PU Drive Wheel & Sprocket-Chain Tensioner arrangement mounted rigidly onto body size. For D2 each movable undercarriage shall be provided with 2 rollers on the shaft for driving, 2 antifriction ball bearing for rolling.The roller assembly comprises of a die-cast step wheel, 2 deep-groove ball bearings and MS shaft. The step wheel is made of cast steel & is fitted onto the MS shaft using a feather key. The two ball bearings are then fastened on either side of the step wheel using circlips. This entire roller assembly is then snap-fitted into a wheel housing. The wheel housing is fixed in the U channel of the understructure using machine screws. This wheel-housing is made of engineering plastic material made by injection moulding process. The entire roller assembly is designed to withstand the maximum loads of the body. Fittings shall be centralized locking arrangement through locking stiffener mounted onto back of single last unit so that it gets locked on channels when all the units are brought together. The Recess handle lock shall be of approved make placed at suitable height.The sprocket-chain arrangement is covered by a 1mm thick. CRCA sheet Drive Unit Cover with dimensions 1202mmx398mmx87mm and is fixed onto the side of the body. The PU handwheel is rigidly fixed at suitable height on side of the body & projects out of cover by another 99mm When the last unit is twin movable, hinged doors as accessories are provided for the end bodies, so in this case locking stiffener is mounted onto drive unit cover. Each Drive Type units shall have Locking Knob near the drive wheel for manual locking of individual units when a person is using those units. Knob shall be rotated to unlock position when units are to be moved. End stoppers shall be provided to prevent derailment.The nuts & bolts are galvanized/blackodized /Zn Plated. Also total no. of loading levels per under structure shall be 10 for SD2.Finish. The bodies including shelves are given antirust surface treatment & are coated with epoxy polyester powder of approved color & shade with dry film thickness of min40 microns. The testing of paint is done for various physical & chemical properties as per IS:101. Label holder at front cover of body of aluminium extrusion of length 396mm for SD. Over that a transparent plastic of corresponding length of 150-200micron polythene is to be inserted. It consists of ‘C’ section 2mm thick HR sheet & Square 25.4mmx2mm thick ERW tube both connected by screws. Hinge Doors & Locking: Hinge Doors shall be made of 0.8thick CRCA steel confirming to IS:513 Grade D. Hinged door provided in each unit have recessed Die cast Handle cum lock with 3 way locking through a lever & shooting bolts. File Separator: File separators 2nos. made of 2mm thick. CRCA sheet (IS:513) shall be provided (b) Same as above with Overall Dimensions of LD-2 Single last Drive Unit 2 Bay(U/C plus Fittings plus Cover) shall be 2400mm (W) x 400mm(D)x2121.5mm(H).(c) Same as above with Overall Dimensions of TD-2 Twin Mobile Drive Unit 2Bay(U/C plus Fittings plus Cover) shall be 2400mm (W)x800mm(D)x2121.5mm(H) for Record Room-3(4mx3.95m)-2 Bay 1 SD 1 TD 1 LD excluding Hinged doors, file separators cost complete with all lead & lift etc, as per specification & as per directed by the Engineer in Charge. | Unit | 366723.94 | 366723.94 | 1.0 | False | None | None | False | None | False | 366723.94 | 0 | 3331959 | 116760 | None | code320 | 2BAY OPTIMIZER PLUS-DRIVE TYPE (1200W, 400D,1980H) (a)Overall Dimensions of SD-2 Single Drive Cover Unit 2Bay(U/C plus Fittings plus Cover) shall be 2400mm(W)x400mm (D)x2121.5mm(H). The Construction shall be rigid knock down made out of 0.8 thick CRCA steel conforming to IS:513. Epoxy polyester powder coated finish thickness of 40microns. Shelf construction shall be made from CRCA steel 0.8mm thick IS:513.Uniformly distributed load capacity of 100Kg. Undercarriage shall have construction in welded frame made of HR sheet 3mm thick conforming to IS:2062. The Movement shall be Drive Type configuration:In case of D2, movement of units is achieved mechanically through a PU Drive Wheel & Sprocket-Chain Tensioner arrangement mounted rigidly onto body size. For D2 each movable undercarriage shall be provided with 2 rollers on the shaft for driving, 2 antifriction ball bearing for rolling.The roller assembly comprises of a die-cast step wheel, 2 deep-groove ball bearing and MS shaft. The step wheel is made of cast steel & is fitted onto the MS shaft using a feather key. The two ball bearing are then fastened on either side of the step wheel using circlip. This entire roller assembly is then snap-fitted into a wheel housing. The wheel housing is fixed in the U channel of the understructure using machine screw. This wheel-housing is made of engineering plastic material made by injection moulding process. The entire roller assembly is designed to withstand the maximum load of the body. Fitting shall be centralized locking arrangement through locking stiffener mounted onto back of single last unit so that it get locked on channels when all the unit are brought together. The Recess handle lock shall be of approved make placed at suitable height.The sprocket-chain arrangement is covered by a 1mm thick. CRCA sheet Drive Unit Cover with dimensions 1202mmx398mmx87mm and is fixed onto the side of the body. The PU handwheel is rigidly fixed at suitable height on side of the body & project out of cover by another 99mm When the last unit is twin movable, hinged doors as accessories are provided for the end bodies, so in this case locking stiffener is mounted onto drive unit cover. Each Drive Type units shall have Locking Knob near the drive wheel for manual locking of individual units when a person is using those units. Knob shall be rotated to unlock position when units are to be moved. End stoppers shall be provided to prevent derailment.The nuts & bolts are galvanized/blackodized/Zn Plated. Also total no. of loading levels per under structure shall be 10 for SD2.Finish. The bodies including shelves are given antirust surface treatment & are coated with epoxy polyester powder of approved color & shade with dry film thickness of min40 microns. The testing of paint is done for various physical & chemical properties as per IS:101. Label holder at front cover of body of aluminium extrusion of length 396mm for SD. Over that a transparent plastic of corresponding length of 150-200micron polythene is to be inserted. It consists of ‘C’ section 2mm thick HR sheet & Square 25.4mmx2mm thick ERW tube both connected by screw. Hinge Door & Locking: Hinge Doors shall be made of 0.8thick CRCA steel confirming to IS:513 Grade D. Hinged door provided in each unit have recessed Die cast Handle cum lock with 3 way locking through a lever & shooting bolt. File Separator: File separator 2nos made of 2mm thick. CRCA sheet (IS:513) shall be provided (b) Same as above with Overall Dimensions of LD-2 Single last Drive Unit 2 Bay(U/C plus Fittings plus Cover) shall be 2400mm (W)x 400mm(D)x2121.5mm(H).(c) Same as above with Overall Dimensions of TD-2 Twin Mobile Drive Unit 2Bay(U/C plus Fittings plus Cover) shall be 2400mm (W)x800mm(D)x2121.5mm(H) for Record Room-4(4mx8.20m), Next room to record room-4 (10.2mx8.20m) 2Bay 1SD 5TD 1LD, excluding Hinged door, file separator cost complete with all lead & lift etc, as per specification & as per directed by the Engineer in Charge | Unit | 1014625.36 | 1014625.36 | 2.0 | False | None | None | False | None | False | 2029250.72 | 0 | 3331960 | 116760 | None | code321 | 3BAY OPTIMIZER PLUS-DRIVE TYPE (1200W, 400D,1980H) (a)Overall Dimensions of SD 3Single Drive Cover Unit 3Bay(U/C plus Fittings plus Cover) shall be 3600mm(W)x400mm(D)x2121.5mm(H). The Construction shall be rigid knock down made out of 0.8thick CRCA steel conforming to IS:513. Each body shall have a main unit plus two add on units.Finish shall be Epoxy polyester powder coated thickness of 40microns. Shelf construction shall be made from CRCA steel 0.8mm thick IS:513.Uniformly distributed load capacity of 100Kg. Undercarriage shall have construction in welded frame made of HR sheet 3mm thick conforming to IS:2062. The Movements shall be Drive Type configuration: In case of D3 movement of units is achieved mechanically through a PU Drive Wheel and Sprocket Chain Tensioner arrangement mounted rigidly onto body size. For D3 each movable undercarriage shall be provided with 3 rollers on the shaft for driving, 3 antifriction ball bearing for rolling.LD under structure has 2 nos. of anti-tilt bearing assembly.The roller assembly comprises of a die-cast step wheel, 2 deep-groove ball bearings and a MS shaft. The step wheel is made of cast steel and is fitted onto the MS shaft using a feather key. The two ball bearings are then fastened on either side of the step wheel using circlips. This entire roller assembly is then snap-fitted into wheel housing. The wheel housing is fixed in the U channel of the under structure using machine screws. This wheel-housing is made of engineering plastic material made by injection-moulding process. The entire roller assembly is designed to withstand the maximum loads of the body. Fittings shall be centralized locking arrangement through locking stiffener mounted onto back of single last unit so that it gets locked on channels when all the units are brought together. The Recess handle lock is of approved make & placed at suitable height. Fixed unit (SD) does not have the Drive Unit Cover. When the last unit is twin movable, hinged doors as accessories are provided for the end bodies, so in this case locking stiffener is mounted onto drive unit cover; & with tile fascia option, it will be mounted in the recess of vertical trim. Each Drive Type units shall have Locking Knob near the drive wheel for manual locking of individual units when a person is using those units. Knob shall be rotated to unlock position when units are to be moved. End stoppers shall be provided to prevent derailment.The nuts & bolts are galvanized/blackodized/Zn Plated. Also total no. of loading levels per under structure shall be 15 for SD3. Finish The bodies including shelves are given antirust surface treatment & are coated with epoxy polyester powder of approved color & shade with dry film thickness of min 40 microns. The testing of paint is done for various physical & chemical properties as per IS:101. Label holder at front cover of body of aluminium extrusion of length 396mm for SD. Over that a transparent plastic of corresponding length of 150-200 micron polythene is to be inserted. It consists of ‘C’ section 2 mm thick HR sheet & Square 25.4mmx2mm thick ERW tube both connected by screws. Hinge Doors & Locking: Hinge Doors shall be made of 0.8thick CRCA steel confirming to IS: 513 Grade D. Hinged door provided in each unit have recessed Die cast Handle cum lock with 3 way locking through a lever & shooting bolts. File Separator: File separators 2nos. made of 2mm thick. CRCA sheet (IS:513) shall be provided. (b) Same as above for Overall Dimensions of LD3 Single last Drive Unit 3 Bay(U/C plus Fittings plus Cover) shall be 3600mm(W)x400mm(D)x2121.5mm(H). (c)Same as above for Overall Dimensions of TD3 Twin Drive Unit 3 bay(U/C plus Fittings plus Cover) shall be 3600mm(W)x800mm(D)x2121.5mm(H) for Record Room 1(10.225mx3.95m), record room-2(10.05mx3.95m)-3 Bay 1SD 1TD 1LD, excluding Hinged doors, file separators cost complete with all lead & lift etc, as per specification & as per directed by the Engineer in Charge | Unit | 519233.04 | 519233.04 | 2.0 | False | None | None | False | None | False | 1038466.08 | 0 | 3331961 | 116760 | None | code322 | 3BAY OPTIMIZER PLUS-DRIVE TYPE (1200W, 400D,1980H) (a)Overall Dimensions of SD 3Single Drive Cover Unit 3Bay(U/C plus Fittings plus Cover) shall be 3600mm(W)x400mm(D)x2121.5mm(H). The Construction shall be rigid knock down made out of 0.8thick CRCA steel conforming to IS:513. Each body shall have a main unit plus two add on units.Finish shall be Epoxy polyester powder coated thickness of 40microns. Shelf construction shall be made from CRCA steel 0.8mm thick IS:513.Uniformly distributed load capacity of 100Kg. Undercarriage shall have construction in welded frame made of HR sheet 3mm thick conforming to IS:2062. The Movements shall be Drive Type configuration: In case of D3 movement of units is achieved mechanically through a PU Drive Wheel and Sprocket Chain Tensioner arrangement mounted rigidly onto body size. For D3 each movable undercarriage shall be provided with 3 rollers on the shaft for driving, 3 antifriction ball bearing for rolling.LD under structure has 2 nos. of anti-tilt bearing assembly.The roller assembly comprises of a die-cast step wheel, 2 deep-groove ball bearings and a MS shaft. The step wheel is made of cast steel and is fitted onto the MS shaft using a feather key. The two ball bearings are then fastened on either side of the step wheel using circlips. This entire roller assembly is then snap-fitted into wheel housing. The wheel housing is fixed in the U channel of the under structure using machine screws. This wheel-housing is made of engineering plastic material made by injection-moulding process. The entire roller assembly is designed to withstand the maximum loads of the body. Fittings shall be centralized locking arrangement through locking stiffener mounted onto back of single last unit so that it gets locked on channels when all the units are brought together. The Recess handle lock is of approved make & placed at suitable height. Fixed unit (SD) does not have the Drive Unit Cover. When the last unit is twin movable, hinged doors as accessories are provided for the end bodies, so in this case locking stiffener is mounted onto drive unit cover; & with tile fascia option, it will be mounted in the recess of vertical trim. Each Drive Type units shall have Locking Knob near the drive wheel for manual locking of individual units when a person is using those units. Knob shall be rotated to unlock position when units are to be moved. End stoppers shall be provided to prevent derailment.The nuts & bolts are galvanized/blackodized/Zn Plated. Also total no. of loading levels per under structure shall be 15 for SD3. Finish The bodies including shelves are given antirust surface treatment & are coated with epoxy polyester powder of approved color & shade with dry film thickness of min 40 microns. The testing of paint is done for various physical & chemical properties as per IS:101. Label holder at front cover of body of aluminium extrusion of length 396mm for SD. Over that a transparent plastic of corresponding length of 150-200 micron polythene is to be inserted. It consists of ‘C’ section 2 mm thick HR sheet & Square 25.4mmx2mm thick ERW tube both connected by screws. Hinge Doors & Locking: Hinge Doors shall be made of 0.8thick CRCA steel confirming to IS: 513 Grade D. Hinged door provided in each unit have recessed Die cast Handle cum lock with 3 way locking through a lever & shooting bolts. File Separator: File separators 2nos. made of 2mm thick. CRCA sheet (IS:513) shall be provided. (b) Same as above for Overall Dimensions of LD3 Single last Drive Unit 3 Bay(U/C plus Fittings plus Cover) shall be 3600mm(W)x400mm(D)x2121.5mm(H). (c)Same as above for Overall Dimensions of TD3 Twin Drive Unit 3 bay(U/C plus Fittings plus Cover) shall be 3600mm(W)x800mm(D)x2121.5mm(H) for Record Room-4(10.20mx8.20m), - 3 Bay 1 SD 5 TD 1 LD, excluding Hinged doors, file separators cost complete with all lead & lift etc, as per specification & as per directed by the Engineer in Charge | Unit | 1443322.9 | 1443322.9 | 1.0 | False | None | None | False | None | False | 1443322.9 | 0 | 3331962 | 116760 | None | code323 | 3BAY OPTIMIZER PLUS-DRIVE TYPE (1200W, 400D,1980H) (a)Overall Dimensions of SD 3Single Drive Cover Unit 3Bay(U/C plus Fittings plus Cover) shall be 3600mm(W)x400mm(D)x2121.5mm(H). The Construction shall be rigid knock down made out of 0.8thick CRCA steel conforming to IS:513. Each body shall have a main unit plus two add on units.Finish shall be Epoxy polyester powder coated thickness of 40microns. Shelf construction shall be made from CRCA steel 0.8mm thick IS:513.Uniformly distributed load capacity of 100Kg. Undercarriage shall have construction in welded frame made of HR sheet 3mm thick conforming to IS:2062. The Movements shall be Drive Type configuration: In case of D3 movement of units is achieved mechanically through a PU Drive Wheel and Sprocket Chain Tensioner arrangement mounted rigidly onto body size. For D3 each movable undercarriage shall be provided with 3 rollers on the shaft for driving, 3 antifriction ball bearing for rolling.LD under structure has 2 nos. of anti-tilt bearing assembly.The roller assembly comprises of a die-cast step wheel, 2 deep-groove ball bearings and a MS shaft. The step wheel is made of cast steel and is fitted onto the MS shaft using a feather key. The two ball bearings are then fastened on either side of the step wheel using circlips. This entire roller assembly is then snap-fitted into wheel housing. The wheel housing is fixed in the U channel of the under structure using machine screws. This wheel-housing is made of engineering plastic material made by injection-moulding process. The entire roller assembly is designed to withstand the maximum loads of the body. Fittings shall be centralized locking arrangement through locking stiffener mounted onto back of single last unit so that it gets locked on channels when all the units are brought together. The Recess handle lock is of approved make & placed at suitable height. Fixed unit (SD) does not have the Drive Unit Cover. When the last unit is twin movable, hinged doors as accessories are provided for the end bodies, so in this case locking stiffener is mounted onto drive unit cover; & with tile fascia option, it will be mounted in the recess of vertical trim. Each Drive Type units shall have Locking Knob near the drive wheel for manual locking of individual units when a person is using those units. Knob shall be rotated to unlock position when units are to be moved. End stoppers shall be provided to prevent derailment.The nuts & bolts are galvanized/blackodized/Zn Plated. Also total no. of loading levels per under structure shall be 15 for SD3. Finish The bodies including shelves are given antirust surface treatment & are coated with epoxy polyester powder of approved color & shade with dry film thickness of min 40 microns. The testing of paint is done for various physical & chemical properties as per IS:101. Label holder at front cover of body of aluminium extrusion of length 396mm for SD. Over that a transparent plastic of corresponding length of 150-200 micron polythene is to be inserted. It consists of ‘C’ section 2 mm thick HR sheet & Square 25.4mmx2mm thick ERW tube both connected by screws. Hinge Doors & Locking: Hinge Doors shall be made of 0.8thick CRCA steel confirming to IS: 513 Grade D. Hinged door provided in each unit have recessed Die cast Handle cum lock with 3 way locking through a lever & shooting bolts. File Separator: File separators 2nos. made of 2mm thick. CRCA sheet (IS:513) shall be provided. (b) Same as above for Overall Dimensions of LD3 Single last Drive Unit 3 Bay(U/C plus Fittings plus Cover) shall be 3600mm(W)x400mm(D)x2121.5mm(H). (c)Same as above for Overall Dimensions of TD3 Twin Drive Unit 3 bay(U/C plus Fittings plus Cover) shall be 3600mm(W)x800mm(D)x2121.5mm(H) for Record Room-7(10.90mx8.20m), - 3 Bay 1 SD 4 TD 1 LD, excluding Hinged doors, file separators cost complete with all lead & lift etc, as per specification & as per directed by the Engineer in Charge | Unit | 1214917.38 | 1214917.38 | 1.0 | False | None | None | False | None | False | 1214917.38 | 0 | 3331963 | 116760 | None | code324 | 3BAY OPTIMIZER PLUS-DRIVE TYPE (1200W, 400D,1980H) (a)Overall Dimensions of SD 3Single Drive Cover Unit 3Bay(U/C plus Fittings plus Cover) shall be 3600mm(W)x400mm(D)x2121.5mm(H). The Construction shall be rigid knock down made out of 0.8thick CRCA steel conforming to IS:513. Each body shall have a main unit plus two add on units.Finish shall be Epoxy polyester powder coated thickness of 40microns. Shelf construction shall be made from CRCA steel 0.8mm thick IS:513.Uniformly distributed load capacity of 100Kg. Undercarriage shall have construction in welded frame made of HR sheet 3mm thick conforming to IS:2062. The Movements shall be Drive Type configuration: In case of D3 movement of units is achieved mechanically through a PU Drive Wheel and Sprocket Chain Tensioner arrangement mounted rigidly onto body size. For D3 each movable undercarriage shall be provided with 3 rollers on the shaft for driving, 3 antifriction ball bearing for rolling.LD under structure has 2 nos. of anti-tilt bearing assembly.The roller assembly comprises of a die-cast step wheel, 2 deep-groove ball bearings and a MS shaft. The step wheel is made of cast steel and is fitted onto the MS shaft using a feather key. The two ball bearings are then fastened on either side of the step wheel using circlips. This entire roller assembly is then snap-fitted into wheel housing. The wheel housing is fixed in the U channel of the under structure using machine screws. This wheel-housing is made of engineering plastic material made by injection-moulding process. The entire roller assembly is designed to withstand the maximum loads of the body. Fittings shall be centralized locking arrangement through locking stiffener mounted onto back of single last unit so that it gets locked on channels when all the units are brought together. The Recess handle lock is of approved make & placed at suitable height. Fixed unit (SD) does not have the Drive Unit Cover. When the last unit is twin movable, hinged doors as accessories are provided for the end bodies, so in this case locking stiffener is mounted onto drive unit cover; & with tile fascia option, it will be mounted in the recess of vertical trim. Each Drive Type units shall have Locking Knob near the drive wheel for manual locking of individual units when a person is using those units. Knob shall be rotated to unlock position when units are to be moved. End stoppers shall be provided to prevent derailment.The nuts & bolts are galvanized/blackodized/Zn Plated. Also total no. of loading levels per under structure shall be 15 for SD3. Finish The bodies including shelves are given antirust surface treatment & are coated with epoxy polyester powder of approved color & shade with dry film thickness of min 40 microns. The testing of paint is done for various physical & chemical properties as per IS:101. Label holder at front cover of body of aluminium extrusion of length 396mm for SD. Over that a transparent plastic of corresponding length of 150-200 micron polythene is to be inserted. It consists of ‘C’ section 2 mm thick HR sheet & Square 25.4mmx2mm thick ERW tube both connected by screws. Hinge Doors & Locking: Hinge Doors shall be made of 0.8thick CRCA steel confirming to IS: 513 Grade D. Hinged door provided in each unit have recessed Die cast Handle cum lock with 3 way locking through a lever & shooting bolts. File Separator: File separators 2nos. made of 2mm thick. CRCA sheet (IS:513) shall be provided. (b) Same as above for Overall Dimensions of LD3 Single last Drive Unit 3 Bay(U/C plus Fittings plus Cover) shall be 3600mm(W)x400mm(D)x2121.5mm(H). (c)Same as above for Overall Dimensions of TD3 Twin Drive Unit 3 bay(U/C plus Fittings plus Cover) shall be 3600mm(W)x800mm(D)x2121.5mm(H) for second floor-3 Bay 1 SD 6 TD 1 LD, excluding Hinged doors, file separators cost complete with all lead & lift etc, as per specification & as per directed by the Engineer in Charge | Unit | 1676962.9 | 1676962.9 | 1.0 | False | None | None | False | None | False | 1676962.9 | 0 | 3331964 | 116760 | None | code325 | Overall Dimension of SD4 SingleDrive CoverUnit 4Bay(U/C plus Fitting plus Cover) shall be 4800mm(W)x400mm(D)x2121.5mm(H).The Construction shall be rigid knock down made out of 0.8thick CRCA steel conforming to IS:513.Each body shall have a main unit plus three add on unit.Finish shall be Epoxy polyester powder coated thickness of 40micron.Shelf construction shall be made from CRCAsteel 0.8mmthick IS:513.Uniformly distributed load capacity of 100Kg.Undercarriage shall have construction in welded frame made of HRsheet 3mm thick conforming to IS:2062.The Movement shall be Drive Type configuration:In case of D4movement of unit is achieved mechanically through a PU Drive Wheel & Sprocket ChainTensioner arrangement mounted rigidly onto body size.For D4 each movable undercarriage shall be provided with 3roller on the shaft for driving 3antifriction ball bearing for rolling.LD under structure has 2no of antitilt bearing assembly.The roller assembly comprises of a die cast step wheel, 2deep groove ball bearing & MS shaft.The step wheel is made of cast steel&is fitted onto the MS shaft using a feather key.The two ball bearing are then fastened on either side of the step wheel using circlip.This entire roller assembly is then snapfitted into wheelhousing.The wheel housing is fixed in the U channel of the under structure using machine screw.This wheelhousing is made of engineering plastic material made by injection moulding process.The entire roller assembly is designed to withstand the maximum load of the body.Fitting shall be centralized locking arrangement through locking stiffener mounted onto back of single last unit so that it get locked on channel when all the unit are brought together.The Recess handle lock is of Godrej make&placed at suitable height.Fixed unit (SD) does not have the Drive Unit Cover.The sprocketchain arrangement is covered by 1mm thick. CRCA sheet Drive Unit Cover with dimension 1302mmx398mmx87mm&is fixed onto the side of the body.The PU handwheel is rigidly fixed at suitable height onside of the body&project out of cover by another 99mm. When the last unit is twin movable hinged door as accessories are provided for the end bodies,so in this case locking stiffener is mounted onto drive unit cover&with tile fascia option it will be mounted in the recess of vertical trim.Each Drive Type unit shall have Locking Knob near the drive wheel for manual locking of individual unit when a person is using those unit.Knob shall be rotated to unlock position when unit are to be moved. End stopper shall be provided to prevent derailment.The nuts&bolt are galvanized/blackodized/Zn Plated. Also total no of loading level per under structure shall be 15 for SD4. Finish The bodies including shelve are given antirust surface treatment&are coated with epoxy polyester powder of approved color&shade with dry film thickness of min 40micron.The testing of paint done for various physical&chemical properties as per IS:101.Label holder at front cover of body of aluminium extrusion of length 396mm for SD.Over that a transparent plastic of corresponding length of 150-200micron polythene is to be inserted (b)Same as above with Overall Dimension of LD4 Single last DriveUnit 4Bay(U/C plus Fitting plus Cover)shall be 4800mm(W)x400mm(D)x2121.5mm(H) (c) Same as above with Overall Dimension of TD4 Twin DriveUnit 4bay(U/Cplus Fittings plusCover) shall be 4800mm(W)x800mm(D)x2121.5mm(H).It consist of C section 2mm thick HRsheet&Square 25.4mmx2mm thick ERW tube-both connected by screw.Hinge Door&Locking Hinge Door shall be made of 0.8thick CRCA steel confirming to IS:513 Grade D Hinged door provided in each unit have recessed Die cast Handle cum lock with 3way locking through a lever&shooting bolt. File separator 2No made of 2mm thick. CRCA sheet (IS:513) shall be provided for Record room2(10.05mx3.95m)4Bay 1SD 1TD 1LD, excluding Hinged door file separator cost complete with all lead & lift etc as per specification &as per direction of Engineer inCharge | Unit | 658277.16 | 658277.16 | 1.0 | False | None | None | False | None | False | 658277.16 | 0 | 3331965 | 116760 | None | code326 | Overall Dimension of SD4 SingleDrive CoverUnit 4Bay(U/C plusFitting plus Cover) shall be 4800mm(W)x400mm(D)x2121.5mm(H).The Construction shall be rigid knock down made out of 0.8thick CRCA steel conforming to IS:513.Each body shall have a main unit plus three add on unit.Finish shall be Epoxy polyester powder coated thickness of 40micron.Shelf construction shall be made from CRCAsteel 0.8mmthickIS:513.Uniformly distributed load capacity of 100Kg.Undercarriage shall have construction in welded frame madeof HRsheet 3mm thick conforming toIS:2062.The Movement shall be DriveType configuration:In case of D4movement of unit is achieved mechanically through a PU Drive Wheel&Sprocket ChainTensioner arrangement mounted rigidly onto body size.For D4 each movable undercarriage shall be provided with 3roller on the shaft for driving 3antifriction ball bearing for rolling.LD under structure has 2no of antitilt bearing assembly.The roller assembly comprises of diecast stepwheel, 2deep groove ball bearing&MS shaft.The step wheel is made of cast steel&is fitted onto the MS shaft using feather key.The two ball bearing are then fastened on either side of step wheel using circlip.This entire roller assembly is then snapfitted into wheelhousing.The wheel housing is fixed in U channel of the under structure using machine screw.This wheelhousing is made of engineering plastic material made by injection moulding process.The entire roller assembly is designed to withstand the maximum load of the body.Fitting shall be centralized locking arrangement through locking stiffener mounted onto back of single last unit so that it get locked on channel when all the unit are brought together.The Recess handle lock is of Godrej make&placed at suitable height.Fixed unit (SD) does not have DriveUnit Cover.The sprocketchain arrangement is covered by 1mm thick. CRCA sheet Drive Unit Cover with dimension 1302mmx398mmx87mm&is fixed onto the side of the body.The PU handwheel is rigidly fixed at suitable height onside of the body&project out of cover by another 99mm. When the last unit is twin movable hinged door as accessories are provided for the end bodies,so in this case locking stiffener is mounted onto drive unit cover&with tile fascia option it will be mounted in recess of vertical trim.Each Drive Type unit shall have Locking Knob near the drive wheel for manual locking of individual unit when a person is using those unit.Knob shall be rotated to unlock position when unit are to be moved.End stopper shall be provided to prevent derailment.The nuts&bolt are galvanized/blackodized/Zn Plated. Also total no of loading level per under structure shall be 15 for SD4.Finish bodies including shelve are given antirust surface treatment&are coated with epoxy polyester powder of approved color&shade with dry film thickness of min 40micron.The testing of paint done for various physical&chemical properties as per IS:101.Label holder at front cover of body of aluminium extrusion of length 396mm for SD.Over that a transparent plastic of corresponding length of 150-200micron polythene is to be inserted (b)Same as above with Overall Dimension of LD4 Single last DriveUnit 4Bay(U/C plus Fitting plus Cover)shall be 4800mm(W)x400mm(D)x2121.5mm(H) (c) Same as above with Overall Dimension of TD4 Twin DriveUnit 4bay(U/Cplus Fittings plusCover) shall be 4800mm(W)x800mm(D)x2121.5mm(H).It consist of Csection 2mm thick HRsheet&Square 25.4mmx2mm thick ERW tubeboth connected by screw.Hinge Door&Locking Hinge Door shall be made of 0.8thick CRCA steel confirming to IS:513 Grade D Hinged door provided in each unit have recessed Die cast Handle cum lock with 3way locking through a lever&shooting bolt. File separator 2No made of 2mm thick.CRCA sheet (IS:513) shall be provided for Record room 4(10.20mx8.20m),Next room to Record room 4(10.20mx8.20m)4Bay 1SD 5TD 1LD, excluding Hinged door file separators cost complete with all lead & lift etc as per specification&as per direction of Engineer inCharge | Unit | 1824563.2 | 1824563.2 | 2.0 | False | None | None | False | None | False | 3649126.4 | 0 | 3331966 | 116760 | None | code327 | Overall Dimension of SD4 SingleDrive CoverUnit 4Bay(U/C plusFitting plus Cover) shall be 4800mm(W)x400mm(D)x2121.5mm(H).The Construction shall be rigid knock down made out of 0.8thick CRCA steel conforming to IS:513.Each body shall have a main unit plus three add on unit.Finish shall be Epoxy polyester powder coated thickness of 40micron.Shelf construction shall be made from CRCAsteel 0.8mmthickIS:513.Uniformly distributed load capacity of 100Kg.Undercarriage shall have construction in welded frame madeof HRsheet 3mm thick conforming toIS:2062.The Movement shall be DriveType configuration:In case of D4movement of unit is achieved mechanically through a PU Drive Wheel&Sprocket ChainTensioner arrangement mounted rigidly onto body size.For D4 each movable undercarriage shall be provided with 3roller on the shaft for driving 3antifriction ball bearing for rolling.LD under structure has 2no of antitilt bearing assembly.The roller assembly comprises of diecast stepwheel, 2deep groove ball bearing&MS shaft.The step wheel is made of cast steel&is fitted onto the MS shaft using feather key.The two ball bearing are then fastened on either side of step wheel using circlip.This entire roller assembly is then snapfitted into wheelhousing.The wheel housing is fixed in U channel of the under structure using machine screw.This wheelhousing is made of engineering plastic material made by injection moulding process.The entire roller assembly is designed to withstand the maximum load of the body.Fitting shall be centralized locking arrangement through locking stiffener mounted onto back of single last unit so that it get locked on channel when all the unit are brought together.The Recess handle lock is of Godrej make&placed at suitable height.Fixed unit (SD) does not have DriveUnit Cover.The sprocketchain arrangement is covered by 1mm thick. CRCA sheet Drive Unit Cover with dimension 1302mmx398mmx87mm&is fixed onto the side of the body.The PU handwheel is rigidly fixed at suitable height onside of the body&project out of cover by another 99mm. When the last unit is twin movable hinged door as accessories are provided for the end bodies,so in this case locking stiffener is mounted onto drive unit cover&with tile fascia option it will be mounted in recess of vertical trim.Each Drive Type unit shall have Locking Knob near the drive wheel for manual locking of individual unit when a person is using those unit.Knob shall be rotated to unlock position when unit are to be moved.End stopper shall be provided to prevent derailment.The nuts&bolt are galvanized/blackodized/Zn Plated. Also total no of loading level per under structure shall be 15 for SD4.Finish bodies including shelve are given antirust surface treatment&are coated with epoxy polyester powder of approved color&shade with dry film thickness of min 40micron.The testing of paint done for various physical&chemical properties as per IS:101.Label holder at front cover of body of aluminium extrusion of length 396mm for SD.Over that a transparent plastic of corresponding length of 150-200micron polythene is to be inserted (b)Same as above with Overall Dimension of LD4 Single last DriveUnit 4Bay(U/C plus Fitting plus Cover)shall be 4800mm(W)x400mm(D)x2121.5mm(H) (c) Same as above with Overall Dimension of TD4 Twin DriveUnit 4bay(U/Cplus Fittings plusCover) shall be 4800mm(W)x800mm(D)x2121.5mm(H).It consist of Csection 2mm thick HRsheet&Square 25.4mmx2mm thick ERW tubeboth connected by screw.Hinge Door&Locking Hinge Door shall be made of 0.8thick CRCA steel confirming to IS:513 Grade D Hinged door provided in each unit have recessed Die cast Handle cum lock with 3way locking through a lever&shooting bolt. File separator 2No made of 2mm thick.CRCA sheet (IS:513) shall be provided for Record room -7(10.90mx8.20m) - 4 Bay 1 SD 4 TD 1 LD,, excluding Hinged door file separators cost complete with all lead & lift etc as per specification&as per direction of Engineer inCharge | Unit | 1536473.28 | 1536473.28 | 1.0 | False | None | None | False | None | False | 1536473.28 | 0 | 3331967 | 116760 | None | code328 | Gain pro: Gain Pro Main 1200W X 450D X 2325H 1 qty Gain Pro Add-on 1200W X 450D X 2325H 2 qty. for Record room-4. complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Unit | 99213.22 | 99213.22 | 1.0 | False | None | None | False | None | False | 99213.22 | 0 | 3331968 | 116760 | None | code329 | Gain pro: Gain Pro Main 1200W X 450D X 1950H 2qty Gain Pro Add-on 1200W X 450D X 1950H 6 qty. for Record room-4 (10.2mx8.20m). complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Unit | 261954.1 | 261954.1 | 1.0 | False | None | None | False | None | False | 261954.1 | 0 | 3331969 | 116760 | None | code330 | Gain pro: Gain Pro Main 1200W X 450D X 1950H 2qty Gain Pro Add-on 1200W X 450D X 1950H 5 qty, Gain Pro Main 900W X 450D X 1950H 1 Qty. for Next room to Record room-4 (10.2mx8.20m). complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Unit | 261454.96 | 261454.96 | 1.0 | False | None | None | False | None | False | 261454.96 | 0 | 3331970 | 116760 | None | code331 | Gain pro: Gain Pro Main 1200W X 450D X 1950H 2qty Gain Pro Add-on 1200W X 450D X 1950H 6 qty, Gain Pro Main 900W X 450D X 1950H 1 Qty. for Record room-7 (10.90mx8.20m). complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Unit | 293219.38 | 293219.38 | 1.0 | False | None | None | False | None | False | 293219.38 | 0 | 3331971 | 116760 | None | code332 | Hinged Doors complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Nos | 9529.92 | 9529.92 | 368.0 | False | None | None | False | None | False | 3507010.56 | 0 | 3331972 | 116760 | None | code333 | File Separators complete with all lead and lift etc, as per specification and as per directed by the Engineer in Charge | Packet | 8117.69 | 8117.69 | 162.0 | False | None | None | False | None | False | 1315065.78 | 0 | 3331973 | 116760 | None | code334 | Electrical Providing Compact substation :
Compact Pre - Fabricated Packaged Sub - Station (as per IEC-60694/IS-3427) 11kV/433V consisting of 3 way SF6/VCB insulated compact RMU, oil cooled CRGO /Amoprhous Core Star - 2 Rated (5 - Star) Transformer and LT section with one MCCB /ACB as incoming and following ougoing MCCB feeders and with enclosure made of electronically galvanized steel sheet (min 2 mm Thickness) with powder coated finish, Copper busbar with LT Metering facility 800 kVA Copper Wound Transformer, 1250 Amps ACB 50 kA 4 pole fixed type micro processor based for LT incomer and 6 Nos. 250 Amps MCCB 4 pole 36 kA TM Based for LT out going with all lead and lifts complete as per specifications and directions of engineer in charge of the work. | Set | 4531655.48 | 4531655.48 | 1.0 | False | None | None | False | None | False | 4531655.48 | 0 | 3331974 | 116760 | None | code335 | Supply of 11 kV HT Metering cubicle of different CT Ratio, Both side cable entry type with 3 CT & 3 PT, With Transparent Cover TTB, with 30x8 mm Copper Busbar, Modem & 2 No of Meters for 3 Phase 4 Wire Metering without Load Break Switch (HT Metering Box Fabricated out of 3 mm MS Sheet duly epoxy powder coated) as per revised Specification with all lead and lifts complete as per specifications and directions of engineer in charge of the work. | No | 316026.66 | 316026.66 | 1.0 | False | None | None | False | None | False | 316026.66 | 0 | 3331975 | 116760 | None | code336 | Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc. using 40 mm dia 2.9 mm thick 2.5m long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode.The funnel should be enclosed in a CC chamber of 400x400x400 mm with a cast iron cover. The earth electrode shall have staggered holes of 12 mm dia and the electrode should be covered 150 mm all-round with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts with all lead and lifts complete as per specifications and directions of engineer in charge of the work. | No | 5524.29 | 5524.29 | 37.0 | False | None | None | False | None | False | 204398.73 | 0 | 3331976 | 116760 | None | code337 | Supply of GI/Copper/plate for grounding connections using necessary grounding materials with all lead and lifts complete as per specifications and directions of engineer in charge of the work. 600 x 600 x 3 mm Copper plate | No | 9632.46 | 9632.46 | 12.0 | False | None | None | False | None | False | 115589.52 | 0 | 3331977 | 116760 | None | code338 | Supply of GI/Copper/plate for grounding connections using necessary grounding materials with all lead and lifts complete as per specifications and directions of engineer in charge of the work.40 x 6 mm GI strip | m | 234.94 | 234.94 | 220.0 | False | None | None | False | None | False | 51686.8 | 0 | 3331978 | 116760 | None | code339 | Supply of GI/Copper/plate for grounding connections using necessary grounding materials with all lead and lifts complete as per specifications and directions of engineer in charge of the work. 25 x 6 mm GI strip | m | 166.14 | 166.14 | 420.0 | False | None | None | False | None | False | 69778.8 | 0 | 3331979 | 116760 | None | code340 | Supply of GI/Copper/plate for grounding connections using necessary grounding materials with all lead and lifts complete as per specifications and directions of engineer in charge of the work. 25 x 3 mm GI strip (Including Chemical earthing) | m | 106.44 | 106.44 | 220.0 | False | None | None | False | None | False | 23416.8 | 0 | 3331980 | 116760 | None | code341 | Supply of GI/Copper/plate for grounding connections using necessary grounding materials with all lead and lifts complete as per specifications and directions of engineer in charge of the work. 25 x 6 mm Copper strip (Including Chemical earthing) | m | 1427.8 | 1427.8 | 250.0 | False | None | None | False | None | False | 356950.0 | 0 | 3331981 | 116760 | None | code342 | Providing, Laying and Fixing of GI pipes conforming to IS 1239:1990 with latest amendments complete with GI fittings (excluding the cost of fittings) with cuts and threads wherever necessary, including testing for water tightness, with all lead and commissioning. (contractor will make his own arrangements for procuring water for testing) For:Heavy Duty GI Pipe etc. with all lead and lifts complete as per specifications and directions of engineer in charge of the work. GI Pipe - 65 mm Dia | Mtr | 933.26 | 933.26 | 10.0 | False | None | None | False | None | False | 9332.6 | 0 | 3331982 | 116760 | None | code343 | Providing, Laying and Fixing of GI pipes conforming to IS 1239:1990 with latest amendments complete with GI fittings (excluding the cost of fittings) with cuts and threads wherever necessary, including testing for water tightness, with all lead and commissioning. (contractor will make his own arrangements for procuring water for testing) For:Heavy Duty GI Pipe etc. with all lead and lifts complete as per specifications and directions of engineer in charge of the work. GI Pipe - 100 mm Dia | Mtr | 1616.01 | 1616.01 | 22.0 | False | None | None | False | None | False | 35552.22 | 0 | 3331983 | 116760 | None | code344 | Supplying of 11 KV (E) 3 core 240 sqmm compacted circular aluminium conductor XLPE insulated screen with semicon & copper tape screened and colour strip with pressure extruded PVC inner sheath round wired steel armoured dry cured as per IS 7098/11-1985 or latest amendment with all lead and lifts complete as per specifications and directions of engineer in charge of the work. | Km | 2149550.3 | 2149550.3 | 0.3 | False | None | None | False | None | False | 644865.09 | 0 | 3331984 | 116760 | None | code345 | Supplying of HT heat shrinkable push on type 11KV 3 core 240 sqmm XLPE UG cable Indoor/Outdoor termination kit with all lead and lifts complete as per specifications and directions of engineer in charge of the work. Indoor termination kit | Nos | 6088.92 | 6088.92 | 8.0 | False | None | None | False | None | False | 48711.36 | 0 | 3331985 | 116760 | None | code346 | Supplying of HT heat shrinkable straight through joint kit for 11KV 3 core 240 sqmm XLPE UG cable with all lead and lifts complete as per specifications and directions of engineer in charge of the work. | Nos | 11436.68 | 11436.68 | 2.0 | False | None | None | False | None | False | 22873.36 | 0 | 3331986 | 116760 | None | code347 | Supply of manufacture sand for spreading and forming alround the UG cable with all lead and lifts complete as per specifications and directions of engineer in charge of the work. | Cum | 2318.23 | 2318.23 | 12.5 | False | None | None | False | None | False | 28977.875 | 0 | 3331987 | 116760 | None | code348 | Supply of Cable Covering Tiles 250x125x40 mm or 125x125x40 mm with all lead and lifts complete as per specifications and directions of engineer in charge of the work. | No | 13.3 | 13.3 | 2000.0 | False | None | None | False | None | False | 26600.0 | 0 | 3331988 | 116760 | None | code349 | Supplying of ‘B’ class 100mm dia GI pipe for culvert crossing and cable raising with all lead and lifts complete as per specifications and directions of engineer in charge of the work. | Mtr | 1603.03 | 1603.03 | 25.0 | False | None | None | False | None | False | 40075.75 | 0 | 3331989 | 116760 | None | code350 | Supplying and Providing Pre cast Cable Route/ Joint marker using M15 grade Concrete, MS rods of approved size/shape (as per the approved drawings) to be laid in UG cable works. The rate includes the cost of material, labour charges, loading, unloading, handling, transportation charges, required tools and plants etc., complete. Work shall be carried out as per the instructions of Engineer-in-charge of works as per the standard procedure with all lead and lifts complete as per specifications and directions of engineer in charge of the work. | Nos | 443.92 | 443.92 | 5.0 | False | None | None | False | None | False | 2219.6 | 0 | 3331990 | 116760 | None | code351 | Laying of UG cable by Trench less technology by adopting horizontal baring and drawing of cables including preparation at side without HDPE pipe with all lead and lifts complete as per specifications and directions of engineer in charge of the work. Normal soil 6” bore size | Mtr | 1231.8 | 1231.8 | 50.0 | False | None | None | False | None | False | 61590.0 | 0 | 3331991 | 116760 | None | code352 | Supply of RCC Hume Pipe, 2000 mm Long, 150 mm Dia with all lead and lifts complete as per specifications and directions of engineer in charge of the work. | No | 398.49 | 398.49 | 180.0 | False | None | None | False | None | False | 71728.2 | 0 | 3331992 | 116760 | None | code353 | Supply of Collars for RCC Hume Pipe with all lead and lifts complete as per specifications and directions of engineer in charge of the work. | No | 106.44 | 106.44 | 90.0 | False | None | None | False | None | False | 9579.6 | 0 | 3331993 | 116760 | None | code354 | Supply of Caution/Danger Board with all lead and lifts complete as per specifications and directions of engineer in charge of the work. | No | 194.7 | 194.7 | 16.0 | False | None | None | False | None | False | 3115.2 | 0 | 3331994 | 116760 | None | code355 | Supplying & running of GI/Copper strips for grounding connections, using necessary fixing materials as required with all lead and lifts complete as per specifications and directions of engineer in charge of the work. 50 x 6 mm GI strip | Mtr | 282.96 | 282.96 | 60.0 | False | None | None | False | None | False | 16977.6 | 0 | 3331995 | 116760 | None | code356 | Supply of Providing Reinforecement TMT Fe 550/550 D with all lead and lifts complete as per specifications and directions of engineer in charge of the work. | Kg | 94.75 | 94.75 | 510.0 | False | None | None | False | None | False | 48322.5 | 0 | 3331996 | 116760 | None | code357 | Providing chain link fencing 50 mm size of 8 guage properly stretched between rectangular Poles and fixed with suitable bolts & nuts, the free ends shall be welded to the Pole and block pipe at top and bottom as required including cost of all materials, labour, lead and lifts, cutting, bending wherever necessary, wastage and lapping etc., complete as per the direction of the engineer incharge for work including two coats of approved quality paint over one coat of primer paint with all lead and lifts complete as per specifications and directions of engineer in charge of the work. | Sqm | 1281.13 | 1281.13 | 80.5 | False | None | None | False | None | False | 103130.965 | 0 | 3331997 | 116760 | None | code358 | Supplying & fixing M.S rectangular poles made out of 2 equal angles of 65* 65*6 mm welded together & fixed in cc (1:2:4) with 2 nos 16mm dia M.S hold fast rods each of lenth 25 cms, Including cost of all materials cutting bending scaffolding wherever necessary, nicely finishing the welded joints with all lead lifts & as per the directions of the Engineer-in-charge of the work and including providing 2 coats of approved quality pain over one coat of shop painting (excluding cost of earth work &concrete) with all lead and lifts complete as per specifications and directions of engineer in charge of the work. | Mtr | 1063.06 | 1063.06 | 111.2 | False | None | None | False | None | False | 118212.272 | 0 | 3331998 | 116760 | None | code359 | Supplying of Frame of MS Channel 100x50 mm and MS angle 40x40x5 mm welding etc., complete. For RMU/DG/DTC with all lead and lifts complete as per specifications and directions of engineer in charge of the work. | Kg | 88.26 | 88.26 | 408.0 | False | None | None | False | None | False | 36010.08 | 0 | 3331999 | 116760 | None | code360 | Fixing foundation frame of channels and angle iron welding fixing in concrete aligning the RMU/DG/DTC/MC on foundation bed, assembly of units, connecting Bus Bars from panel to panel initial filling of oil etc., with all lead and lifts complete as per specifications and directions of engineer in charge of the work. 3 Panel | No | 20076.17 | 20076.17 | 3.0 | False | None | None | False | None | False | 60228.51 | 0 | 3332000 | 116760 | None | code361 | Lettering the RMU with enamel paint and also writing single line diagram of each panel, caution Board, Danger Board etc., including cost of Paint, Brush etc., with all lead and lifts complete as per specifications and directions of engineer in charge of the work. | No | 1247.38 | 1247.38 | 2.0 | False | None | None | False | None | False | 2494.76 | 0 | 3332001 | 116760 | None | code362 | Erection of HT metering Cubicle on Platform with all lead and lifts complete as per specifications and directions of engineer in charge of the work. | No | 2393.51 | 2393.51 | 1.0 | False | None | None | False | None | False | 2393.51 | 0 | 3332002 | 116760 | None | code363 | Erection of danger boards with all lead and lifts complete as per specifications and directions of engineer in charge of the work. | No | 103.84 | 103.84 | 16.0 | False | None | None | False | None | False | 1661.44 | 0 | 3332003 | 116760 | None | code364 | Erection of Compact Pre-fabricated Packaged Sub-station 11kV/433 V Installing & fixing the Compact Pre-Fabricated Packaged Sub- Station 100/250/500 /800/ 1000 kVA transformer on the existing concrete plinth.(This does not include the cost of plinth, cable duct, laying & termination of cable etc. provision for the same shall be made) with all lead and lifts complete as per specifications and directions of engineer in charge of the work. | No | 54791.18 | 54791.18 | 1.0 | False | None | None | False | None | False | 54791.18 | 0 | 3332004 | 116760 | None | code365 | Laying of high tension 11 KV(E) 3 core 240 sqmm in existing trench/GI pipe/stone ware/RCC Hume pipe using wooden aluminum rollers as directed by the departmental staff with all lead and lifts complete as per specifications and directions of engineer in charge of the work. a. 3X300 to 3X500sqmm. | Km | 83270.59 | 83270.59 | 0.3 | False | None | None | False | None | False | 24981.177 | 0 | 3332005 | 116760 | None | code366 | Refilling the cable Trenches with selected available earth from trench excavated including watering consolidation in layers of 15cm thickness including depositing of the surplus earth with a lead of 200 mtr with all lead and lifts complete as per specifications and directions of engineer in charge of the work. | Cum | 207.68 | 207.68 | 270.0 | False | None | None | False | None | False | 56073.6 | 0 | 3332006 | 116760 | None | code367 | Making and fixing for 11 KV(E) 3 Core 240 sqmm heat shrinkable type pot head (indoor / out door) with all lead and lifts complete as per specifications and directions of engineer in charge of the work. 3X300 to 3X400 sqmm. | Nos | 3450.08 | 3450.08 | 8.0 | False | None | None | False | None | False | 27600.64 | 0 | 3332007 | 116760 | None | code368 | Making and fixing for 11 KV (E) 3 core 240 sqmm heat shrinkable type straight through joint with all lead and lifts complete as per specifications and directions of engineer in charge of the work.3X300 to 3X400 sqmm. | Nos | 3696.7 | 3696.7 | 2.0 | False | None | None | False | None | False | 7393.4 | 0 | 3332008 | 116760 | None | code369 | Spreading and forming with sand all round the cable to a depth of 75mm and width of 500mm with all lead and lifts complete as per specifications and directions of engineer in charge of the work. | Km | 19223.38 | 19223.38 | 0.25 | False | None | None | False | None | False | 4805.845 | 0 | 3332009 | 116760 | None | code370 | Earth work excavation for HT/LT cable RMU/DG/MC/LBS , RMU’s & OD’s trench of 0.5 to 0.75 Mtr width and depth upto 1 Mtr including trial pits depositing on bank up to a lead of 50 Mtr supplying and displaying necessary danger boards and lighting using sight rails and sign boards at every 100 Mtrs wherever necessary as directed with all lead and lifts complete as per specifications and directions of engineer in charge of the work. In ordinary soil | Cum | 340.08 | 340.08 | 270.0 | False | None | None | False | None | False | 91821.6 | 0 | 3332010 | 116760 | None | code371 | Concreting with CC 1:2:4 [M-15] Using 20mm Nominal size graded crushed coarse aggregates and also for concrete slabs with all lead and lifts complete as per specifications and directions of engineer in charge of the work. | Cum | 8103.41 | 8103.41 | 55.0 | False | None | None | False | None | False | 445687.55 | 0 | 3332011 | 116760 | None | code372 | KSRB 4-6.5: Providing and removing centering, shuttering, stutting, propping etc, and removal of form work for columns, pillars, post and struts, square/rectangular / polygon in plan including cost of all materials, labour complete with all lead and lifts complete as per specifications and directions of engineer in charge of the work. | Sqm | 591.89 | 591.89 | 175.0 | False | None | None | False | None | False | 103580.75 | 0 | 3332012 | 116760 | None | code373 | Covering the tiles of 250X250X40mm for 3 core 400sqmm XLPE UG cable with all lead and lifts complete as per specifications and directions of engineer in charge of the work. | Km | 5668.37 | 5668.37 | 0.25 | False | None | None | False | None | False | 1417.0925 | 0 | 3332013 | 116760 | None | code374 | Laying the GI pipe 80mm to 150mm dia at Drainage water supply crossing including fixing collars, bends tees and other fitting with cuts and threads wherever necessary complete with all lead and lifts complete as per specifications and directions of engineer in charge of the work. | Mtr | 120.71 | 120.71 | 25.0 | False | None | None | False | None | False | 3017.75 | 0 | 3332014 | 116760 | None | code375 | SUPPLY OF LT CABLES:
Supply of 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath
Armoured LTUG Cable as per IS-1554 (Part-
1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 with all lead and lifts complete as per specifications and directions of engineer in charge of the work. 300 Sqmm, 3.5 Core, (32 GI Strips - 4 x 0.8 mm) | m | 1383.69 | 1383.69 | 450.0 | False | None | None | False | None | False | 622660.5 | 0 | 3332015 | 116760 | None | code376 | Supply of 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath
Armoured LTUG Cable as per IS-1554 (Part-
1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 with all lead and lifts complete as per specifications and directions of engineer in charge of the work. 240 Sqmm, 3.5 Core, (30 GI Strips - 4 x 0.8 mm) | m | 1119.74 | 1119.74 | 775.0 | False | None | None | False | None | False | 867798.5 | 0 | 3332016 | 116760 | None | code377 | Supply of 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath
Armoured LTUG Cable as per IS-1554 (Part-
1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 with all lead and lifts complete as per specifications and directions of engineer in charge of the work. 185 Sqmm, 3.5 Core, (28 GI Strips - 4 x 0.8 mm) | m | 897.2 | 897.2 | 360.0 | False | None | None | False | None | False | 322992.0 | 0 | 3332017 | 116760 | None | code378 | Supply of 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath
Armoured LTUG Cable as per IS-1554 (Part-
1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 with all lead and lifts complete as per specifications and directions of engineer in charge of the work. 120 Sqmm, 3.5 Core, (25 GI Strips - 4 x 0.8 mm) | m | 593.04 | 593.04 | 525.0 | False | None | None | False | None | False | 311346.0 | 0 | 3332018 | 116760 | None | code379 | Supply of 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath
Armoured LTUG Cable as per IS-1554 (Part-
1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 with all lead and lifts complete as per specifications and directions of engineer in charge of the work. 70 Sqmm, 3.5 Core, (18 GI Strips - 4 x 0.8 mm) | m | 412.65 | 412.65 | 280.0 | False | None | None | False | None | False | 115542.0 | 0 | 3332019 | 116760 | None | code380 | Supply of 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath
Armoured LTUG Cable as per IS-1554 (Part-
1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 with all lead and lifts complete as per specifications and directions of engineer in charge of the work. 16 Sqmm, 4 Core, (11 GI Strips - 4 x 0.8 mm) | m | 184.11 | 184.11 | 1050.0 | False | None | None | False | None | False | 193315.5 | 0 | 3332020 | 116760 | None | code381 | Supply of Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 with all lead and lifts complete as per specifications and directions of engineer in charge of the work. 4C x 6 Sq mm Steel armoured Cu control cable | m | 320.61 | 320.61 | 1050.0 | False | None | None | False | None | False | 336640.5 | 0 | 3332021 | 116760 | None | code382 | Supply of Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 with all lead and lifts complete as per specifications and directions of engineer in charge of the work. 4C x 10 Sq mm Steel armoured Cu control cable | m | 486.75 | 486.75 | 350.0 | False | None | None | False | None | False | 170362.5 | 0 | 3332022 | 116760 | None | code383 | Supply of Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 with all lead and lifts complete as per specifications and directions of engineer in charge of the work. 1C x 10Sq mm Steel armoured Cu control cable | m | 216.77 | 216.77 | 1400.0 | False | None | None | False | None | False | 303478.0 | 0 | 3332023 | 116760 | None | code384 | Supply of Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 with all lead and lifts complete as per specifications and directions of engineer in charge of the work. 3C x 2.5 mm2 | m | 146.67 | 146.67 | 3540.0 | False | None | None | False | None | False | 519211.8 | 0 | 3332024 | 116760 | None | code385 | Supply of Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 with all lead and lifts complete as per specifications and directions of engineer in charge of the work. 3C x 4 mm2 | m | 223.26 | 223.26 | 6800.0 | False | None | None | False | None | False | 1518168.0 | 0 | 3332025 | 116760 | None | code386 | Supply of Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 with all lead and lifts complete as per specifications and directions of engineer in charge of the work. 4C x 16 Sq mm | m | 726.88 | 726.88 | 150.0 | False | None | None | False | None | False | 109032.0 | 0 | 3332026 | 116760 | None | code387 | Supply of Epoxy Terminating Kit (Pothead) suitable for 1.1 kV, LTUG Cable with all lead and lifts complete as per specifications and directions of engineer in charge of the work. Up to 4C x 50 Sqmm | Set | 420.55 | 420.55 | 78.0 | False | None | None | False | None | False | 32802.9 | 0 | 3332027 | 116760 | None | code388 | Supply of Epoxy Terminating Kit (Pothead) suitable for 1.1 kV, LTUG Cable with all lead and lifts complete as per specifications and directions of engineer in charge of the work. 3.5 x 70/95/120 Sqmm | Set | 495.84 | 495.84 | 26.0 | False | None | None | False | None | False | 12891.84 | 0 | 3332028 | 116760 | None | code389 | Supply of Epoxy Terminating Kit (Pothead) suitable for 1.1 kV, LTUG Cable with all lead and lifts complete as per specifications and directions of engineer in charge of the work. 3.5 x 150/185 Sqmm | Set | 623.04 | 623.04 | 8.0 | False | None | None | False | None | False | 4984.32 | 0 | 3332029 | 116760 | None | code390 | Supply of Epoxy Terminating Kit (Pothead) suitable for 1.1 kV, LTUG Cable with all lead and lifts complete as per specifications and directions of engineer in charge of the work. 3.5 x 225/240/300 Sqmm | Set | 763.22 | 763.22 | 24.0 | False | None | None | False | None | False | 18317.28 | 0 | 3332030 | 116760 | None | code391 | LABOUR CHARGES FOR LAYING OF LT CABLES::
Laying of cable in Existing Trench/GI pipe/ Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff LT Cable with all lead and lifts complete as per specifications and directions of engineer in charge of the work. 2.5 to 25 Sqmm | m | 27.11 | 27.11 | 11050.0 | False | None | None | False | None | False | 299565.5 | 0 | 3332031 | 116760 | None | code392 | Laying of cable in Existing Trench/GI pipe/ Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff LT Cable with all lead and lifts complete as per specifications and directions of engineer in charge of the work. 35 to 95 Sqmm | m | 40.42 | 40.42 | 280.0 | False | None | None | False | None | False | 11317.6 | 0 | 3332032 | 116760 | None | code393 | Laying of cable in Existing Trench/GI pipe/ Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff LT Cable with all lead and lifts complete as per specifications and directions of engineer in charge of the work. 120 to 240 Sqmm | m | 41.9 | 41.9 | 775.0 | False | None | None | False | None | False | 32472.5 | 0 | 3332033 | 116760 | None | code394 | Laying of cable in Existing Trench/GI pipe/ Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff LT Cable with all lead and lifts complete as per specifications and directions of engineer in charge of the work. 300 to 400 Sqmm | m | 44.36 | 44.36 | 450.0 | False | None | None | False | None | False | 19962.0 | 0 | 3332034 | 116760 | None | code395 | Making and Fixing pot head LT UG Cable Heat shrinkable Type Terminations with all lead and lifts complete as per specifications and directions of engineer in charge of the work. 2.5 to 25 Sqmm | Set | 122.01 | 122.01 | 78.0 | False | None | None | False | None | False | 9516.78 | 0 | 3332035 | 116760 | None | code396 | Making and Fixing pot head LT UG Cable Heat shrinkable Type Terminations with all lead and lifts complete as per specifications and directions of engineer in charge of the work. 35 to 95 Sqmm | Set | 246.62 | 246.62 | 26.0 | False | None | None | False | None | False | 6412.12 | 0 | 3332036 | 116760 | None | code397 | Making and Fixing pot head LT UG Cable Heat shrinkable Type Terminations with all lead and lifts complete as per specifications and directions of engineer in charge of the work. 120 to 240 Sqmm | Set | 307.63 | 307.63 | 8.0 | False | None | None | False | None | False | 2461.04 | 0 | 3332037 | 116760 | None | code398 | Making and Fixing pot head LT UG Cable Heat shrinkable Type Terminations with all lead and lifts complete as per specifications and directions of engineer in charge of the work. 300 to 400 Sqmm | Set | 432.23 | 432.23 | 24.0 | False | None | None | False | None | False | 10373.52 | 0 | 3332038 | 116760 | None | code399 | EXTERNAL LIGHTING DB:F abricating supplying and mounting MS box made out ....SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., with all lead and lifts complete as per specifications and directions of engineer in charge of the work. 14 SWG | Sq CM | 0.65 | 0.65 | 30000.0 | False | None | None | False | None | False | 19500.0 | 0 | 3332039 | 116760 | None | code400 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 with all lead and lifts complete as per specifications and directions of engineer in charge of the work. 6-32 A SP | Each | 538.67 | 538.67 | 18.0 | False | None | None | False | None | False | 9696.06 | 0 | 3332040 | 116760 | None | code401 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 with all lead and lifts complete as per specifications and directions of engineer in charge of the work. 6-32 A DP | Each | 959.22 | 959.22 | 1.0 | False | None | None | False | None | False | 959.22 | 0 | 3332041 | 116760 | None | code402 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 with all lead and lifts complete as per specifications and directions of engineer in charge of the work. 6-32 A TPN | Each | 2228.67 | 2228.67 | 2.0 | False | None | None | False | None | False | 4457.34 | 0 | 3332042 | 116760 | None | code403 | Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V upto 300mA sensitivity on existing wood/ panel board with all lead and lifts complete as per specifications and directions of engineer in charge of the work. 63 A 4 pole | Each | 7197.41 | 7197.41 | 1.0 | False | None | None | False | None | False | 7197.41 | 0 | 3332043 | 116760 | None | code404 | Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz 12/24V D.C. with all lead and lifts complete as per specifications and directions of engineer in charge of the work. | Each | 668.47 | 668.47 | 3.0 | False | None | None | False | None | False | 2005.41 | 0 | 3332044 | 116760 | None | code405 | Supply and fixing of 3pole power contactor with NO/NC contacts on existing wood/panel board using necessary bolts, nuts, washers and wiring etc., complete with AC-3 Rating and as per IS-13947 with all lead and lifts complete as per specifications and directions of engineer in charge of the work. 40 A | Each | 2930.88 | 2930.88 | 2.0 | False | None | None | False | None | False | 5861.76 | 0 | 3332045 | 116760 | None | code406 | Supplying and fixing Microprocessor based Electronic timer (without contactor, Din Mounting using necessary bolts, nuts and washers etc.,.) 3-120sec setting with all lead and lifts complete as per specifications and directions of engineer in charge of the work. | Each | 3004.87 | 3004.87 | 2.0 | False | None | None | False | None | False | 6009.74 | 0 | 3332046 | 116760 | None | code407 | BUILDING WIRING For B2, B1, G, 1, 2, 3, 4, 5, 6 FLOORS:
Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure III - Double Door 12 Way TP & N & N with all lead and lifts complete as per specifications and directions of engineer in charge of the work. II - Double Door 12 Way SP & N | Each | 3023.04 | 3023.04 | 8.0 | False | None | None | False | None | False | 24184.32 | 0 | 3332047 | 116760 | None | code408 | Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure III - Double Door 12 Way TP & N & N with all lead and lifts complete as per specifications and directions of engineer in charge of the work. III - Double Door 12 Way TP & N | Each | 11338.03 | 11338.03 | 15.0 | False | None | None | False | None | False | 170070.45 | 0 | 3332048 | 116760 | None | code409 | Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure III - Double Door 12 Way TP & N & N with all lead and lifts complete as per specifications and directions of engineer in charge of the work. III - Double Door16 Way TP & N | Each | 13492.71 | 13492.71 | 5.0 | False | None | None | False | None | False | 67463.55 | 0 | 3332049 | 116760 | None | code410 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 with all lead and lifts complete as per specifications and directions of engineer in charge of the work. 6-32 A SP | Each | 538.67 | 538.67 | 860.0 | False | None | None | False | None | False | 463256.2 | 0 | 3332050 | 116760 | None | code411 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 with all lead and lifts complete as per specifications and directions of engineer in charge of the work. 50-63 A DP | Each | 1430.4 | 1430.4 | 60.0 | False | None | None | False | None | False | 85824.0 | 0 | 3332051 | 116760 | None | code412 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 with all lead and lifts complete as per specifications and directions of engineer in charge of the work. 50-63 A TPN | Each | 4008.22 | 4008.22 | 20.0 | False | None | None | False | None | False | 80164.4 | 0 | 3332052 | 116760 | None | code413 | Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V upto 300mA sensitivity on existing wood/ panel board with all lead and lifts complete as per specifications and directions of engineer in charge of the work. 63 A 4 pole | Each | 7197.41 | 7197.41 | 28.0 | False | None | None | False | None | False | 201527.48 | 0 | 3332053 | 116760 | None | code414 | Supplying heavy gauge PVC conduit pipe ...... mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary with all lead and lifts complete as per specifications and directions of engineer in charge of the work. 25 mm dia 2 mm thick | m | 105.14 | 105.14 | 14440.0 | False | None | None | False | None | False | 1518221.6 | 0 | 3332054 | 116760 | None | code415 | Supplying heavy gauge PVC conduit pipe ...... mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary with all lead and lifts complete as per specifications and directions of engineer in charge of the work. 32 mm dia 2.5 mm thick | m | 137.59 | 137.59 | 1815.0 | False | None | None | False | None | False | 249725.85 | 0 | 3332055 | 116760 | None | code416 | Extra for Groove cutting in brick wall/CC floor to the suitable depth for concealing of Conduit/GI pipe and plastering, finishing upto wall surface with all lead and lifts complete as per specifications and directions of engineer in charge of the work. upto 50 mm conduit in brick wall | m | 37.64 | 37.64 | 3500.0 | False | None | None | False | None | False | 131740.0 | 0 | 3332056 | 116760 | None | code417 | Extra for Groove cutting in brick wall/CC floor to the suitable depth for concealing of Conduit/GI pipe and plastering, finishing upto wall surface with all lead and lifts complete as per specifications and directions of engineer in charge of the work. upto 50 mm conduit CC floor | m | 89.56 | 89.56 | 6200.0 | False | None | None | False | None | False | 555272.0 | 0 | 3332057 | 116760 | None | code418 | Supplying PVC flexible conduit pipe .... mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300 mm using NF screws and on either end of the pipe terminated completely with all lead and lifts complete as per specifications and directions of engineer in charge of the work. 25 mm | m | 28.56 | 28.56 | 150.0 | False | None | None | False | None | False | 4284.0 | 0 | 3332058 | 116760 | None | code419 | Supplying PVC flexible conduit pipe .... mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300 mm using NF screws and on either end of the pipe terminated completely with all lead and lifts complete as per specifications and directions of engineer in charge of the work. 32 mm | m | 37.64 | 37.64 | 100.0 | False | None | None | False | None | False | 3764.0 | 0 | 3332059 | 116760 | None | code420 | Supplying And Fixing Metal Fan Box with Round Hook with all lead and lifts complete as per specifications and directions of engineer in charge of the work. | No | 151.87 | 151.87 | 300.0 | False | None | None | False | None | False | 45561.0 | 0 | 3332060 | 116760 | None | code421 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 with all lead and lifts complete as per specifications and directions of engineer in charge of the work. 1.5 mm2 | m | 33.75 | 33.75 | 6355.0 | False | None | None | False | None | False | 214481.25 | 0 | 3332061 | 116760 | None | code422 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 with all lead and lifts complete as per specifications and directions of engineer in charge of the work. 2.5 mm2 | m | 54.52 | 54.52 | 11710.0 | False | None | None | False | None | False | 638429.2 | 0 | 3332062 | 116760 | None | code423 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 with all lead and lifts complete as per specifications and directions of engineer in charge of the work. 4 mm2 | m | 81.77 | 81.77 | 2200.0 | False | None | None | False | None | False | 179894.0 | 0 | 3332063 | 116760 | None | code424 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 with all lead and lifts complete as per specifications and directions of engineer in charge of the work. 6 mm2 | m | 119.42 | 119.42 | 550.0 | False | None | None | False | None | False | 65681.0 | 0 | 3332064 | 116760 | None | code425 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 with all lead and lifts complete as per specifications and directions of engineer in charge of the work. 10mm2 | m | 216.77 | 216.77 | 550.0 | False | None | None | False | None | False | 119223.5 | 0 | 3332065 | 116760 | None | code426 | Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990 with all lead and lifts complete as per specifications and directions of engineer in charge of the work. 3C x 2.5 mm2 | m | 146.67 | 146.67 | 3560.0 | False | None | None | False | None | False | 522145.2 | 0 | 3332066 | 116760 | None | code427 | Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990 with all lead and lifts complete as per specifications and directions of engineer in charge of the work. 3C x 4 mm2 | m | 223.26 | 223.26 | 5007.0 | False | None | None | False | None | False | 1117862.82 | 0 | 3332067 | 116760 | None | code428 | Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet with all lead and lifts complete as per specifications and directions of engineer in charge of the work. Short point upto 3Mtr from tapping point to out let via switch | Point | 349.16 | 349.16 | 760.0 | False | None | None | False | None | False | 265361.6 | 0 | 3332068 | 116760 | None | code429 | Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet with all lead and lifts complete as per specifications and directions of engineer in charge of the work. Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch | Point | 491.94 | 491.94 | 550.0 | False | None | None | False | None | False | 270567.0 | 0 | 3332069 | 116760 | None | code430 | Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet with all lead and lifts complete as per specifications and directions of engineer in charge of the work. Long point above 6Mtr upto 10Mtr from tapping point to out let via switch | Point | 720.39 | 720.39 | 215.0 | False | None | None | False | None | False | 154883.85 | 0 | 3332070 | 116760 | None | code431 | Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet with all lead and lifts complete as per specifications and directions of engineer in charge of the work. Two outlet in a row, above 3Mtr upto 6Mtr from tapping point to out let via switches | Point | 878.75 | 878.75 | 14.0 | False | None | None | False | None | False | 12302.5 | 0 | 3332071 | 116760 | None | code432 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall with all lead and lifts complete as per specifications and directions of engineer in charge of the work. 1-2 Way | Each | 179.12 | 179.12 | 58.0 | False | None | None | False | None | False | 10388.96 | 0 | 3332072 | 116760 | None | code433 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall with all lead and lifts complete as per specifications and directions of engineer in charge of the work. 3 Way | Each | 206.38 | 206.38 | 10.0 | False | None | None | False | None | False | 2063.8 | 0 | 3332073 | 116760 | None | code434 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall with all lead and lifts complete as per specifications and directions of engineer in charge of the work. 4-5 Way | Each | 229.75 | 229.75 | 400.0 | False | None | None | False | None | False | 91900.0 | 0 | 3332074 | 116760 | None | code435 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall with all lead and lifts complete as per specifications and directions of engineer in charge of the work. 6 Way | Each | 285.56 | 285.56 | 180.0 | False | None | None | False | None | False | 51400.8 | 0 | 3332075 | 116760 | None | code436 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall with all lead and lifts complete as per specifications and directions of engineer in charge of the work. 8 Way | Each | 338.78 | 338.78 | 250.0 | False | None | None | False | None | False | 84695.0 | 0 | 3332076 | 116760 | None | code437 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall with all lead and lifts complete as per specifications and directions of engineer in charge of the work. 10-12 Way | Each | 414.06 | 414.06 | 245.0 | False | None | None | False | None | False | 101444.7 | 0 | 3332077 | 116760 | None | code438 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box with all lead and lifts complete as per specifications and directions of engineer in charge of the work. 1 to 2 Module | Each | 177.83 | 177.83 | 58.0 | False | None | None | False | None | False | 10314.14 | 0 | 3332078 | 116760 | None | code439 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box with all lead and lifts complete as per specifications and directions of engineer in charge of the work. 3 Module | Each | 208.98 | 208.98 | 10.0 | False | None | None | False | None | False | 2089.8 | 0 | 3332079 | 116760 | None | code440 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box with all lead and lifts complete as per specifications and directions of engineer in charge of the work. 4 Module | Each | 227.15 | 227.15 | 400.0 | False | None | None | False | None | False | 90860.0 | 0 | 3332080 | 116760 | None | code441 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box with all lead and lifts complete as per specifications and directions of engineer in charge of the work. 6 Module | Each | 303.73 | 303.73 | 180.0 | False | None | None | False | None | False | 54671.4 | 0 | 3332081 | 116760 | None | code442 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box with all lead and lifts complete as per specifications and directions of engineer in charge of the work. 8 Module | Each | 368.63 | 368.63 | 250.0 | False | None | None | False | None | False | 92157.5 | 0 | 3332082 | 116760 | None | code443 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box with all lead and lifts complete as per specifications and directions of engineer in charge of the work. 10-12 Module | Each | 446.51 | 446.51 | 245.0 | False | None | None | False | None | False | 109394.95 | 0 | 3332083 | 116760 | None | code444 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 with all lead and lifts complete as per specifications and directions of engineer in charge of the work. 6A One Way Switch | Each | 132.4 | 132.4 | 2450.0 | False | None | None | False | None | False | 324380.0 | 0 | 3332084 | 116760 | None | code445 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 with all lead and lifts complete as per specifications and directions of engineer in charge of the work. 6A Two Way Switch | Each | 215.47 | 215.47 | 85.0 | False | None | None | False | None | False | 18314.95 | 0 | 3332085 | 116760 | None | code446 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 with all lead and lifts complete as per specifications and directions of engineer in charge of the work. 6A Three Way socket | Each | 221.96 | 221.96 | 1545.0 | False | None | None | False | None | False | 342928.2 | 0 | 3332086 | 116760 | None | code447 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 with all lead and lifts complete as per specifications and directions of engineer in charge of the work. Stepped Fan Regulator Two Module | Each | 463.39 | 463.39 | 70.0 | False | None | None | False | None | False | 32437.3 | 0 | 3332087 | 116760 | None | code448 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 with all lead and lifts complete as per specifications and directions of engineer in charge of the work. 400W Dimmer | Each | 358.25 | 358.25 | 25.0 | False | None | None | False | None | False | 8956.25 | 0 | 3332088 | 116760 | None | code449 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 with all lead and lifts complete as per specifications and directions of engineer in charge of the work. 16A One Way Switch | Each | 233.64 | 233.64 | 430.0 | False | None | None | False | None | False | 100465.2 | 0 | 3332089 | 116760 | None | code450 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 with all lead and lifts complete as per specifications and directions of engineer in charge of the work. 6A Bell Push | Each | 229.75 | 229.75 | 75.0 | False | None | None | False | None | False | 17231.25 | 0 | 3332090 | 116760 | None | code451 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 with all lead and lifts complete as per specifications and directions of engineer in charge of the work.32A DP Switch | Each | 423.15 | 423.15 | 90.0 | False | None | None | False | None | False | 38083.5 | 0 | 3332091 | 116760 | None | code452 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 with all lead and lifts complete as per specifications and directions of engineer in charge of the work. 6/16A Universal Socket | Each | 306.33 | 306.33 | 75.0 | False | None | None | False | None | False | 22974.75 | 0 | 3332092 | 116760 | None | code453 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 with all lead and lifts complete as per specifications and directions of engineer in charge of the work. TV/Telephone Socket | Each | 202.49 | 202.49 | 450.0 | False | None | None | False | None | False | 91120.5 | 0 | 3332093 | 116760 | None | code454 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 with all lead and lifts complete as per specifications and directions of engineer in charge of the work. RJ45/I.O Outlet Cat-6 | Each | 437.43 | 437.43 | 450.0 | False | None | None | False | None | False | 196843.5 | 0 | 3332094 | 116760 | None | code455 | Supplying and drawing UTP-CAT 6E LAN cable with all lead and lifts complete as per specifications and directions of engineer in charge of the work. | m | 49.32 | 49.32 | 17450.0 | False | None | None | False | None | False | 860634.0 | 0 | 3332095 | 116760 | None | code456 | Supplying and drawing PVC insulated gas injected physical foam jelly flooded co-axial TV cable.RG-6. with all lead and lifts complete as per specifications and directions of engineer in charge of the work. | m | 57.11 | 57.11 | 500.0 | False | None | None | False | None | False | 28555.0 | 0 | 3332096 | 116760 | None | code457 | Supplying and fixing of MDF krone junction box with KRONE Module / Telephone cable termination with all lead and lifts complete as per specifications and directions of engineer in charge of the work. 50Pair | No | 819.04 | 819.04 | 10.0 | False | None | None | False | None | False | 8190.4 | 0 | 3332097 | 116760 | None | code458 | Supplying & Fixing of switch mounting rack with power manager & Cable manager with all lead and lifts complete as per specifications and directions of engineer in charge of the work. 32U with 650mm depth | Each | 47003.18 | 47003.18 | 10.0 | False | None | None | False | None | False | 470031.8 | 0 | 3332098 | 116760 | None | code459 | Supplying & Fixing of Patch panel for LAN cabling 24 Port 10/100/1000 patch panel with all lead and lifts complete as per specifications and directions of engineer in charge of the work. | Each | 10254.2 | 10254.2 | 20.0 | False | None | None | False | None | False | 205084.0 | 0 | 3332099 | 116760 | None | code460 | Supplying fixing of Network Switches 24 Port Gigabyte (manageable) with all lead and lifts complete as per specifications and directions of engineer in charge of the work. | Each | 53802.1 | 53802.1 | 20.0 | False | None | None | False | None | False | 1076042.0 | 0 | 3332100 | 116760 | None | code461 | Supplying & Fixing of ... ms Cat 6 Patch Cable with all lead and lifts complete as per specifications and directions of engineer in charge of the work. 1 m | Each | 290.75 | 290.75 | 320.0 | False | None | None | False | None | False | 93040.0 | 0 | 3332101 | 116760 | None | code462 | Supplying & Fixing of ... ms Cat 6 Patch Cable with all lead and lifts complete as per specifications and directions of engineer in charge of the work. 2 m | Each | 333.59 | 333.59 | 300.0 | False | None | None | False | None | False | 100077.0 | 0 | 3332102 | 116760 | None | code463 | Supplying & fixing of I/O socket with back box with all lead and lifts complete as per specifications and directions of engineer in charge of the work. Single I/O | Each | 636.02 | 636.02 | 25.0 | False | None | None | False | None | False | 15900.5 | 0 | 3332103 | 116760 | None | code464 | Supplying & fixing of I/O socket with back box with all lead and lifts complete as per specifications and directions of engineer in charge of the work. Double I/O | Each | 713.9 | 713.9 | 300.0 | False | None | None | False | None | False | 214170.0 | 0 | 3332104 | 116760 | None | code465 | Supplying and drawing PVC insulated gas injected physical foam jelly flooded co-axial TV cable RG-6. with all lead and lifts complete as per specifications and directions of engineer in charge of the work. | m | 57.11 | 57.11 | 300.0 | False | None | None | False | None | False | 17133.0 | 0 | 3332105 | 116760 | None | code466 | Supplying and drawing PVC flexible one pair telephone unarmoured tinned copper cable with all lead and lifts complete as per specifications and directions of engineer in charge of the work. 2Pair | m | 27.26 | 27.26 | 12000.0 | False | None | None | False | None | False | 327120.0 | 0 | 3332106 | 116760 | None | code467 | Supplying and drawing PVC flexible one pair telephone unarmoured tinned copper cable with all lead and lifts complete as per specifications and directions of engineer in charge of the work. 5Pair | m | 59.71 | 59.71 | 5000.0 | False | None | None | False | None | False | 298550.0 | 0 | 3332107 | 116760 | None | code468 | SUPPLY OF LIGHTING FIXTURES:
Supplying of recess mounting non integrated type LED down light...... W luminaire comprising of pressure decast/ extruded aluminium housing, with spring loaded false ceiling clamps, LED of Power/COB with CCT 6500 degree K, CRIgreater than 70%. efficacy greater than100 lumen per W, 120degree beam spread, lifegreater than 25000 burning hours and Compliance to IS10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level. LED's are driven by HF electronic driver integrated in a separate control gear assembly., with PF greater than 0.95, power loss shouldless than 5% of lamp Wage, short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical with all lead and lifts complete as per specifications and directions of engineer in charge of the work.15-18W | Each | 2168.96 | 2168.96 | 241.0 | False | None | None | False | None | False | 522719.36 | 0 | 3332108 | 116760 | None | code469 | Supplying of recess mounting non integral type ........ LED w luminaire comprising of pressure decast/extruded aluminium housing, with spring loaded false ceiling clamps, Power LEDs with CCT 6500 degree K, CRIgreater than 70%. efficacy greater than 100 lumen per W, 120degree beam spread, lifegreater than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF greater than 0.95, power loss shouldless than 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition with all lead and lifts complete as per specifications and directions of engineer in charge of the work. LED modular down light 1'x1' 18W | Each | 4073.12 | 4073.12 | 228.0 | False | None | None | False | None | False | 928671.36 | 0 | 3332109 | 116760 | None | code470 | Supplying of recess mounting non integral type ........ LED w luminaire comprising of pressure decast/extruded aluminium housing, with spring loaded false ceiling clamps, Power LEDs with CCT 6500 degree K, CRIgreater than 70%. efficacy greater than 100 lumen per W, 120degree beam spread, lifegreater than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF greater than 0.95, power loss shouldless than 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition with all lead and lifts complete as per specifications and directions of engineer in charge of the work. LED modular down light 1'x1' 24W | Each | 4792.22 | 4792.22 | 83.0 | False | None | None | False | None | False | 397754.26 | 0 | 3332110 | 116760 | None | code471 | Supplying of recess mounting non integral type ........ LED w luminaire comprising of pressure decast/extruded aluminium housing, with spring loaded false ceiling clamps, Power LEDs with CCT 6500 degree K, CRIgreater than 70%. efficacy greater than 100 lumen per W, 120degree beam spread, lifegreater than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF greater than 0.95, power loss shouldless than 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition with all lead and lifts complete as per specifications and directions of engineer in charge of the work. LED modular down light 2'x2' 36 W | Each | 5909.79 | 5909.79 | 10.0 | False | None | None | False | None | False | 59097.9 | 0 | 3332111 | 116760 | None | code472 | Supplying of recess mounting non integral type ........ LED w luminaire comprising of pressure decast/extruded aluminium housing, with spring loaded false ceiling clamps, Power LEDs with CCT 6500 degree K, CRIgreater than 70%. efficacy greater than 100 lumen per W, 120degree beam spread, lifegreater than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF greater than 0.95, power loss shouldless than 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition with all lead and lifts complete as per specifications and directions of engineer in charge of the work. LED modular down light 2'x2' 40-42W | Each | 6309.58 | 6309.58 | 236.0 | False | None | None | False | None | False | 1489060.88 | 0 | 3332112 | 116760 | None | code473 | Supplying & fixing - flexible LED Strip Light ..... W Power consumption in 5 ms length CCT6500 degree K, CRIgreater than 70%.efficacy greater than80 lumen per W, lifegreater than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver non integrated, with PF greater than 0.95, power loss shouldless than 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved with 2 years Warranty against any manufacturing defect working under standard electrical condition with all lead and lifts complete as per specifications and directions of engineer in charge of the work. | m | 1675.72 | 1675.72 | 1055.0 | False | None | None | False | None | False | 1767884.6 | 0 | 3332113 | 116760 | None | code474 | Supplying of .....feet -PVC Batten with integrated LED tube .... W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI greater than 80. Power Input: 220- 240V@ 50/60Hz & Power factor greater than0.9 along with CE approved. 2
years Warranty against any manufacturing defect working under standard electrical condition with all lead and lifts complete as per specifications and directions of engineer in charge of the work. LED light fitting 1 x 4' - 36/40 W | Each | 1647.16 | 1647.16 | 350.0 | False | None | None | False | None | False | 576506.0 | 0 | 3332114 | 116760 | None | code475 | Supply of LED floodlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/clear glass material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, CCT greater than 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire greater than IK08. Power Factor greater than0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mauling with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100 V to 270V 50/60Hz application. Compliance to IS 10322/ IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ....... W System Power consumption. LED Efficiencygreater than 1301m/w, nominal CRI greater than75. Luminaire manufacturer should have in- house facility accredited by NABL / CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark / name shall be Engraved / Embossing on the die cast housing / Body part Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ umileds/ Osram make LED Source with all lead and lifts complete as per specifications and directions of engineer in charge of the work. LED Floodlight 150W | Each | 16212.02 | 16212.02 | 8.0 | False | None | None | False | None | False | 129696.16 | 0 | 3332115 | 116760 | None | code476 | Supply of LED pole mounting type post top lantern with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/ clear glass material, delivering superior light outputRated life Burning Hrs 50000 hr@ Lumen Maintenance of 70%, CCT greater than 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire greater than IK08. Power Factorgreater than0.9 with mains, Surge Protection- Min 5KV along with Over voltage/Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/1 EC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB LED Efficiencygreater than1301m/w, nominal CRI greater than75. Luminaire manufacturer should have in- house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001 :2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds /Osram make LED Source. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds /Osram make LED Source with all lead and lifts complete as per specifications and directions of engineer in charge of the work. LED Post Top Lantern with 45 W | Each | 15573.4 | 15573.4 | 16.0 | False | None | None | False | None | False | 249174.4 | 0 | 3332116 | 116760 | None | code477 | Supplying and fixing of LED Bulkhead of 10W with IP65 protection and IK 08 impact resistance suitable for surface and wall mounting applications with all lead and lifts complete as per specifications and directions of engineer in charge of the work. | Each | 1092.92 | 1092.92 | 10.0 | False | None | None | False | None | False | 10929.2 | 0 | 3332117 | 116760 | None | code478 | LABOUR CHARGES FOR LIGHTING FIXTURES: Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling / rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clamps with all lead and lifts complete as per specifications and directions of engineer in charge of the work. On wall/ ceiling / Rafter / Girders | Each | 158.36 | 158.36 | 1137.0 | False | None | None | False | None | False | 180055.32 | 0 | 3332118 | 116760 | None | code479 | Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling / rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clamps with all lead and lifts complete as per specifications and directions of engineer in charge of the work. Using necessary length of G.I. chain | Each | 341.37 | 341.37 | 800.0 | False | None | None | False | None | False | 273096.0 | 0 | 3332119 | 116760 | None | code480 | Fixing all types and all capacities of 1'x4' / 2'x2' LED Light fittings indoor on the wall / ceiling / rafters / girders with necessary supporting frame, using 2310.0076" twin twisted PVC insulated wires, required Nos of round blocks and clamps with all lead and lifts complete as per specifications and directions of engineer in charge of the work. | Each | 636.02 | 636.02 | 400.0 | False | None | None | False | None | False | 254408.0 | 0 | 3332120 | 116760 | None | code481 | SUPPLY PORTION FOR UPS, FANS & AC's:
Supplying, erecting, testing & Commissioning of ON-LINE UPS system / inverter suitable for operation on 230V, 50Hz, A/C supply, with isolation transformer all accessories complete and Excluding batteries and wiring complete with all lead and lifts complete as per specifications and directions of engineer in charge of the work. 10 kVA ON LINE UPS | Each | 134433.86 | 134433.86 | 6.0 | False | None | None | False | None | False | 806603.16 | 0 | 3332121 | 116760 | None | code482 | Supplying, installation, testing & commissioning of 12V ..AH batteries in poly propylene container for D.G. sets. Low maintenance batteries, plate type with all lead and lifts complete as per specifications and directions of engineer in charge of the work. 100 AH capacity | Each | 26132.63 | 26132.63 | 96.0 | False | None | None | False | None | False | 2508732.48 | 0 | 3332122 | 116760 | None | code483 | Supplying of 1440rpm heavy duty exhaust fan with bracket blades suitable to operate on 230V 50Hz, AC Supply with all lead and lifts complete as per specifications and directions of engineer in charge of the work. 12" Sweep (300 mm) | Each | 3853.76 | 3853.76 | 50.0 | False | None | None | False | None | False | 192688.0 | 0 | 3332123 | 116760 | None | code484 | Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/19 and also comply with IS: 1709/1984 with latest amendment, Rated voltage 220 V/50 Hz, Rated power upto 35 W +/- 10 %, Rated current As per IS:374/19, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value 6.2 CMM / W, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201, as per IS specification, Motor winding. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 V, Insulation resistance Shall not be less than Two Mega Ohms (2M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, W& current, Air Delivery & Fan Speed as per IS:374/2019 with latest amendment, 2year manufacturer Warranty. (BLDC fans) 56" Sweep 5 Star (1400 mm) with all lead and lifts complete as per specifications and directions of engineer in charge of the work. | Each | 6170.69 | 6170.69 | 70.0 | False | None | None | False | None | False | 431948.3 | 0 | 3332124 | 116760 | None | code485 | Supplying wall mounting fan suitable to operate at single- phase 230v AC. supply. 400 mm Sweep with all lead and lifts complete as per specifications and directions of engineer in charge of the work. | Each | 4169.18 | 4169.18 | 10.0 | False | None | None | False | None | False | 41691.8 | 0 | 3332125 | 116760 | None | code486 | Supplying of .. TR Invertor type split Air conditioners suitable for operation on A/C supply single phase 50 Hz 230 V with hermetically sealed inverter compressor with air cooled condenser, latest R410A / R-32 refrigerant fan motor, start & run capacitors, relay & over load protector internal unit, with one indoor & one outdoor unit The condenser unit will be placed outside the room avoid noise including standard length of suitable size copper tubing covered with nitrile rubber insulation tube. suitable capacity 3 core sheathed/ PVC copper cable and a battery operated wireless remote unit with all lead and lifts complete as per specifications and directions of engineer in charge of the work. 1.0 Ton capacity | Each | 66960.26 | 66960.26 | 15.0 | False | None | None | False | None | False | 1004403.9 | 0 | 3332126 | 116760 | None | code487 | Supplying of .. TR Invertor type split Air conditioners suitable for operation on A/C supply single phase 50 Hz 230 V with hermetically sealed inverter compressor with air cooled condenser, latest R410A / R-32 refrigerant fan motor, start & run capacitors, relay & over load protector internal unit, with one indoor & one outdoor unit The condenser unit will be placed outside the room avoid noise including standard length of suitable size copper tubing covered with nitrile rubber insulation tube. suitable capacity 3 core sheathed/ PVC copper cable and a battery operated wireless remote unit with all lead and lifts complete as per specifications and directions of engineer in charge of the work. 1.5 Ton capacity | Each | 79347.84 | 79347.84 | 20.0 | False | None | None | False | None | False | 1586956.8 | 0 | 3332127 | 116760 | None | code488 | Supply erection, testing, commissioning of Cassette type split Air conditioners suitable for operation on single/three phase AC supply, hermetically sealed compressor with air cooled condenser motor capacitor start, capacitors run relay and over load protection, one ceiling mounted indoor unit and one outdoor condenser unit including standard accessories covered with insulation tube including battery operated cordless unit with all lead and lifts complete as per specifications and directions of engineer in charge of the work. 2 TR Cassette 1 Ph | No | 110971.52 | 110971.52 | 45.0 | False | None | None | False | None | False | 4993718.4 | 0 | 3332128 | 116760 | None | code489 | Supply erection, testing, commissioning of Cassette type split Air conditioners suitable for operation on single/three phase AC supply, hermetically sealed compressor with air cooled condenser motor capacitor start, capacitors run relay and over load protection, one ceiling mounted indoor unit and one outdoor condenser unit including standard accessories covered with insulation tube including battery operated cordless unit with all lead and lifts complete as per specifications and directions of engineer in charge of the work. 3 TR Cassette 3 Ph | No | 148004.74 | 148004.74 | 15.0 | False | None | None | False | None | False | 2220071.1 | 0 | 3332129 | 116760 | None | code490 | Supplying, erecting, testing and commissioning of voltage stabilizer suitable for 170 to 270 v input and load variation from no load to full load, with over load protection, spike suppression, operating at 00 C to 400 C. Range etc., with all lead and lifts complete as per specifications and directions of engineer in charge of the work. 4kVA Capacity | Each | 6747.14 | 6747.14 | 35.0 | False | None | None | False | None | False | 236149.9 | 0 | 3332130 | 116760 | None | code491 | Supplying, erecting, testing and commissioning of voltage stabilizer suitable for 170 to 270 v input and load variation from no load to full load, with over load protection, spike suppression, operating at 00 C to 400 C. Range etc., with all lead and lifts complete as per specifications and directions of engineer in charge of the work. 5kVA Capacity | Each | 13609.73 | 13609.73 | 60.0 | False | None | None | False | None | False | 816583.8 | 0 | 3332131 | 116760 | None | code492 | Supplying and installation of insulated refrigerant copper tubing of 5/8" and 3/8" with polythene foam insulation 3 core 80 stand copper wiring between indoor and outdoor unit Leak testing oil and gas charging for additional piping length of tube with all lead and lifts complete as per specifications and directions of engineer in charge of the work. Split | m | 2180.99 | 2180.99 | 350.0 | False | None | None | False | None | False | 763346.5 | 0 | 3332132 | 116760 | None | code493 | Supplying and installation of insulated refrigerant copper tubing of 5/8" and 3/8" with polythene foam insulation 3 core 80 stand copper wiring between indoor and outdoor unit Leak testing oil and gas charging for additional piping length of tube with all lead and lifts complete as per specifications and directions of engineer in charge of the work. Cassette | m | 2307.71 | 2307.71 | 600.0 | False | None | None | False | None | False | 1384626.0 | 0 | 3332133 | 116760 | None | code494 | Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990 with all lead and lifts complete as per specifications and directions of engineer in charge of the work. 3C x 2.5 mm2 | m | 146.67 | 146.67 | 350.0 | False | None | None | False | None | False | 51334.5 | 0 | 3332134 | 116760 | None | code495 | Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990 with all lead and lifts complete as per specifications and directions of engineer in charge of the work. 3C x 4 mm2 | m | 223.26 | 223.26 | 450.0 | False | None | None | False | None | False | 100467.0 | 0 | 3332135 | 116760 | None | code496 | Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990 with all lead and lifts complete as per specifications and directions of engineer in charge of the work. 4C x 4 mm2 | m | 292.05 | 292.05 | 150.0 | False | None | None | False | None | False | 43807.5 | 0 | 3332136 | 116760 | None | code497 | Providing and fixing chlorinated polyviinyl chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, includes fixing the pipe with clamps at 1.00M spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints with all lead and lifts complete as per specifications and directions of engineer in charge of the work. 25mm nominal dia Pipes | m | 412.76 | 412.76 | 150.0 | False | None | None | False | None | False | 61914.0 | 0 | 3332137 | 116760 | None | code498 | LABOUR CHARGES FOR UPS, FANS & AC's : Installation charges for split / cassette type air conditioner with allied works for one indoor and one outdoor unit is to be mounted on suitable Angle Iron support upto 3.0 Ton split/cassette type A/C. with all lead and lifts complete as per specifications and directions of engineer in charge of the work. | Each | 4470.4 | 4470.4 | 95.0 | False | None | None | False | None | False | 424688.0 | 0 | 3332138 | 116760 | None | code499 | Fixing a ceiling /wall mounting fan of all capacities and all types, with necessary clamps and 'S' hook made out of 15mm dia MS rod, with 5 A. ceiling rose of approved quality with necessary length of 23/0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size wooden board and wired with all lead and lifts complete as per specifications and directions of engineer in charge of the work. | Each | 408.87 | 408.87 | 80.0 | False | None | None | False | None | False | 32709.6 | 0 | 3332139 | 116760 | None | code500 | Fixing one exhaust fan after making a suitable notch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 A, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame with all lead and lifts complete as per specifications and directions of engineer in charge of the work. | Each | 917.69 | 917.69 | 50.0 | False | None | None | False | None | False | 45884.5 | 0 | 3332140 | 116760 | None | code501 | CABLE TRAY, RACEWAY & OTHER ITEM : Supply and laying of underfloor (concealed) raceways manufactured from 1.5 mm thick cover and base (including partitions for multi- compartment raceways), zero spangle pre-galvanized sheet steel with 275 GSM ( 36.67 microns) coating mass, cover and base MIG welded together. the length of raceways shall be 2.5 meters per length with single accessories acting as duct connector including fastening clamps and vertical access boxes and with all required connected accessories complete and load bearing capacity in line with EN 50085-2-2 with all lead and lifts complete as per specifications and directions of engineer in charge of the work. 50 x 38 x 2500mm, 1 compartment | m | 819.04 | 819.04 | 180.0 | False | None | None | False | None | False | 147427.2 | 0 | 3332141 | 116760 | None | code502 | Supply and laying of underfloor (concealed) raceways manufactured from 1.5 mm thick cover and base (including partitions for multi- compartment raceways), zero spangle pre-galvanized sheet steel with 275 GSM ( 36.67 microns) coating mass, cover and base MIG welded together. the length of raceways shall be 2.5 meters per length with single accessories acting as duct connector including fastening clamps and vertical access boxes and with all required connected accessories complete and load bearing capacity in line with EN 50085-2-2 with all lead and lifts complete as per specifications and directions of engineer in charge of the work. 75 x 38 x 2500mm, 1 compartment | m | 960.52 | 960.52 | 200.0 | False | None | None | False | None | False | 192104.0 | 0 | 3332142 | 116760 | None | code503 | Supply and laying of underfloor (concealed) raceways manufactured from 1.5 mm thick cover and base (including partitions for multi- compartment raceways), zero spangle pre-galvanized sheet steel with 275 GSM ( 36.67 microns) coating mass, cover and base MIG welded together. the length of raceways shall be 2.5 meters per length with single accessories acting as duct connector including fastening clamps and vertical access boxes and with all required connected accessories complete and load bearing capacity in line with EN 50085-2-2 with all lead and lifts complete as per specifications and directions of engineer in charge of the work. 100 x 38 x 2500mm, 1 compartment | m | 1159.11 | 1159.11 | 250.0 | False | None | None | False | None | False | 289777.5 | 0 | 3332143 | 116760 | None | code504 | Supply and laying of underfloor (concealed) raceways manufactured from 1.5 mm thick cover and base (including partitions for multi- compartment raceways), zero spangle pre-galvanized sheet steel with 275 GSM ( 36.67 microns) coating mass, cover and base MIG welded together. the length of raceways shall be 2.5 meters per length with single accessories acting as duct connector including fastening clamps and vertical access boxes and with all required connected accessories complete and load bearing capacity in line with EN 50085-2-2 with all lead and lifts complete as per specifications and directions of engineer in charge of the work. 150 x 38 x 2500mm, 2 compartments | m | 2163.77 | 2163.77 | 300.0 | False | None | None | False | None | False | 649131.0 | 0 | 3332144 | 116760 | None | code505 | Supply and laying of underfloor (concealed) raceways manufactured from 1.5 mm thick cover and base (including partitions for multi- compartment raceways), zero spangle pre-galvanized sheet steel with 275 GSM ( 36.67 microns) coating mass, cover and base MIG welded together. the length of raceways shall be 2.5 meters per length with single accessories acting as duct connector including fastening clamps and vertical access boxes and with all required connected accessories complete and load bearing capacity in line with EN 50085-2-2 with all lead and lifts complete as per specifications and directions of engineer in charge of the work. 200 x 38 x 2500mm, 2 compartments | m | 2803.68 | 2803.68 | 400.0 | False | None | None | False | None | False | 1121472.0 | 0 | 3332145 | 116760 | None | code506 | Supply and laying of under floor junction boxes shall be of three-piece construction -Base box, frame and load plate. Base box shall be robust in its construction manufactured from 1.5 mm thick zero spangle pre- galvanized sheet steel with 275 GSM ( 36.67 microns) coating mass. The load plate and frame thicknesses shall be 3 mm and 2 mm respectively to provide adequate load bearing capacity of 5 kN with deflection not greater than 6mm while loading and permanent deflection not exceeding 3 mm as per EN 50085-2-2. The trap and frame shall be Epoxy coated to protect from corrosion. The junction boxes shall be 10 mm or 20 mm recess to accommodate floor covering suitable for Tile/Carpet/marble / granite/according to site conditions. The junction box has height of 60mm up to finished floor level. The base of junction boxes should have pre-punched sealing arrangements on all four sides to accept either 25 mm or 38 mm of
metal raceways with all lead and lifts complete as per specifications and directions of engineer in charge of the work. For (50-100x38mm) duct.Dimensions: 170 mm x 170 mm x 56 mm | Nos | 1701.68 | 1701.68 | 120.0 | False | None | None | False | None | False | 204201.6 | 0 | 3332146 | 116760 | None | code507 | Supply and laying of under floor junction boxes shall be of three-piece construction -Base box, frame and load plate. Base box shall be robust in its construction manufactured from 1.5 mm thick zero spangle pre- galvanized sheet steel with 275 GSM ( 36.67 microns) coating mass. The load plate and frame thicknesses shall be 3 mm and 2 mm respectively to provide adequate load bearing capacity of 5 kN with deflection not greater than 6mm while loading and permanent deflection not exceeding 3 mm as per EN 50085-2-2. The trap and frame shall be Epoxy coated to protect from corrosion. The junction boxes shall be 10 mm or 20 mm recess to accommodate floor covering suitable for Tile/Carpet/marble / granite/according to site conditions. The junction box has height of 60mm up to finished floor level. The base of junction boxes should have pre-punched sealing arrangements on all four sides to accept either 25 mm or 38 mm of
metal raceways with all lead and lifts complete as per specifications and directions of engineer in charge of the work. For (50-200x38mm) duct.Dimensions: 240 mm x 240 mm x 56 mm | Nos | 2257.22 | 2257.22 | 290.0 | False | None | None | False | None | False | 654593.8 | 0 | 3332147 | 116760 | None | code508 | Supply and laying of under floor junction boxes shall be of three-piece construction -Base box, frame and load plate. Base box shall be robust in its construction manufactured from 1.5 mm thick zero spangle pre- galvanized sheet steel with 275 GSM ( 36.67 microns) coating mass. The load plate and frame thicknesses shall be 3 mm and 2 mm respectively to provide adequate load bearing capacity of 5 kN with deflection not greater than 6mm while loading and permanent deflection not exceeding 3 mm as per EN 50085-2-2. The trap and frame shall be Epoxy coated to protect from corrosion. The junction boxes shall be 10 mm or 20 mm recess to accommodate floor covering suitable for Tile/Carpet/marble / granite/according to site conditions. The junction box has height of 60mm up to finished floor level. The base of junction boxes should have pre-punched sealing arrangements on all four sides to accept either 25 mm or 38 mm of
metal raceways with all lead and lifts complete as per specifications and directions of engineer in charge of the work. For (50-300x38mm) duct.Dimensions: 340 mm x 340 mm x 56 mm | Nos | 3474.75 | 3474.75 | 15.0 | False | None | None | False | None | False | 52121.25 | 0 | 3332148 | 116760 | None | code509 | Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint with all lead and lifts complete as per specifications and directions of engineer in charge of the work. 40 x 40 x 6 mm | m | 395.89 | 395.89 | 420.0 | False | None | None | False | None | False | 166273.8 | 0 | 3332149 | 116760 | None | code510 | Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint with all lead and lifts complete as per specifications and directions of engineer in charge of the work. 50 x 50 x 6 mm | m | 512.71 | 512.71 | 180.0 | False | None | None | False | None | False | 92287.8 | 0 | 3332150 | 116760 | None | code511 | Supplying and Fixing 2 mm thick perforated cable GI tray with on existing MS angle support using necessary GI bolts/nuts and washer or welding as required with all lead and lifts complete as per specifications and directions of engineer in charge of the work. 150 x 50 mm | m | 600.97 | 600.97 | 150.0 | False | None | None | False | None | False | 90145.5 | 0 | 3332151 | 116760 | None | code512 | Supplying and Fixing 2 mm thick perforated cable GI tray with on existing MS angle support using necessary GI bolts/nuts and washer or welding as required with all lead and lifts complete as per specifications and directions of engineer in charge of the work. 450 x 50 mm | m | 1185.07 | 1185.07 | 300.0 | False | None | None | False | None | False | 355521.0 | 0 | 3332152 | 116760 | None | code513 | Supplying and Fixing 2 mm thick perforated cable GI tray with on existing MS angle support using necessary GI bolts/nuts and washer or welding as required with all lead and lifts complete as per specifications and directions of engineer in charge of the work. 600 x 50 mm | m | 1526.45 | 1526.45 | 200.0 | False | None | None | False | None | False | 305290.0 | 0 | 3332153 | 116760 | None | code514 | Supplying and installation of RUBBER MAT 1mtr x 1mtr -1Omm thick. complete including cost of materials, labour, usage charges of machinery complete as per specifications with all lead and lifts complete as per specifications and directions of engineer in charge of the work. | Each | 2466.2 | 2466.2 | 22.0 | False | None | None | False | None | False | 54256.4 | 0 | 3332154 | 116760 | None | code515 | Supply and Fixing RCC Hume Pipe 2000 mm long 150 mm Dia with all lead and lifts complete as per specifications and directions of engineer in charge of the work. | No | 398.49 | 398.49 | 7.0 | False | None | None | False | None | False | 2789.43 | 0 | 3332155 | 116760 | None | code516 | Supplying of first aid box with all lead and lifts complete as per specifications and directions of engineer in charge of the work. | Each | 778.8 | 778.8 | 7.0 | False | None | None | False | None | False | 5451.6 | 0 | 3332156 | 116760 | None | code517 | Supplying of Hand gloves with all lead and lifts complete as per specifications and directions of engineer in charge of the work. | Each | 1265.55 | 1265.55 | 7.0 | False | None | None | False | None | False | 8858.85 | 0 | 3332157 | 116760 | None | code518 | Supplying of FIRST AID CHART with lamination with all lead and lifts complete as per specifications and directions of engineer in charge of the work. | Each | 519.2 | 519.2 | 7.0 | False | None | None | False | None | False | 3634.4 | 0 | 3332158 | 116760 | None | code519 | Providing Laminated SLD with all lead and lifts complete as per specifications and directions of engineer in charge of the work. | Nos | 220.66 | 220.66 | 7.0 | False | None | None | False | None | False | 1544.62 | 0 | 3332159 | 116760 | None | code520 | Supply and Fixing FIRE FIGHTING EQUIPMENT (with necessary mounting stand) Foam Extinguishing Type 9 Litre with all lead and lifts complete as per specifications and directions of engineer in charge of the work. | No | 5345.16 | 5345.16 | 20.0 | False | None | None | False | None | False | 106903.2 | 0 | 3332160 | 116760 | None | code521 | Supply and Fixing Water Mist & CAF Low Pressure Backpack Type fire extinguisher with special foam 9 Litre with all lead and lifts complete as per specifications and directions of engineer in charge of the work. | No | 6408.23 | 6408.23 | 20.0 | False | None | None | False | None | False | 128164.6 | 0 | 3332161 | 116760 | None | code522 | Supply and Fixing Sand Type G.I. Buckets : 9 Litre with all lead and lifts complete as per specifications and directions of engineer in charge of the work. | No | 782.69 | 782.69 | 4.0 | False | None | None | False | None | False | 3130.76 | 0 | 3332162 | 116760 | None | code523 | Supply and Fixing Sand Type G.I. Steel stands with all lead and lifts complete as per specifications and directions of engineer in charge of the work. | No | 3065.88 | 3065.88 | 1.0 | False | None | None | False | None | False | 3065.88 | 0 | 3332163 | 116760 | None | code524 | DIESEL GENERATOR SET: SUPPLY PORTION FOR DG WORKS: 320 KVA/256 kw DG SET WITH ACOUSTIC ENCLOSURE with all lead and lifts complete as per specifications and directions of engineer in charge of the work. (the bidder shall quote as per detail Specificatios specified in section 7 of Bid Document) | Set | 3433003.62 | 3433003.62 | 1.0 | False | None | None | False | None | False | 3433003.62 | 0 | 3332164 | 116760 | None | code525 | Supply, Erection, testing and commissioning of AMF panel suitable for .....kVA DG set. The panel is of cubical type base/floor mounting control panel with hinged doors, undrilled bottom gland plate, aluminium Bus Bar with the accommodation for .....A 4 pole contactor for alternator with thermal O/L relay,..... A 4 pole contactor for mains, HRC fuse for short circuit protection, Microprocessor based AMF module with supply failure timer, Restoration timer, 3 impulse automatic engine start/stop logic, Mains/generator voltage, ....capacity bypass switch and frequency sensing, PCC 1301controller with water temperature/ Lube oil pressure/ engine speed, oltage/ampere /Frequency/ kVA, Running-hour count, No of starts, Fault indication, over / under speed, Fails to start, Low oil pleasure, High engine temperature, Under/over voltage, over current, Earth fault relay, with indications for Mains on, Load on Mains, Battery charger on Push buttons AMF module by pass Mode, Battery charger unit with inbuilt auto/Manual and Flat/Boost facility. The complete set shall have sufficient safety and adhere to NEC, NBC 2016, IEC, CPWD specifications, PCB norms and KSGEI Acts and Rules with all lead and lifts complete as per specifications and directions of engineer in charge of the work. 320 KVA to 400 KVA | Each | 406028.68 | 406028.68 | 1.0 | False | None | None | False | None | False | 406028.68 | 0 | 3332165 | 116760 | None | code526 | Supplying & Fixing Chemical earthling for grounding. Conduits, IC cut-outs & other equipments backfill compound which is noncorrosive, thermally conductive, potential to permissible limits, superior Fault conduction capacity, non toxic, weather resistance & capable of achieving ohmic value less than one ohm Using 6ft. Copper bonded rod with backfill compound with all lead and lifts complete as per specifications and directions of engineer in charge of the work. | 1 Kit | 8086.54 | 8086.54 | 20.0 | False | None | None | False | None | False | 161730.8 | 0 | 3332166 | 116760 | None | code527 | PROVIDING STREET LIGHTS :
Supplying of 1.1 KV LT UG cable having aluminium conductor PVC insulated, extruded inner sheathed, galvanized, steel strip (except 2Cx10Sq.mm wire armoured) confirming to IS-3975:1990 (No. of strip indicated in GTP) & extruded PVC outer sheathed armoured cable with specified IS-1554 Part- 1:1988 & confirming to GTP of GROUP- A with all lead and lifts complete as per specifications and directions of engineer in charge of the work.10 Sqmm, 4 Core, (10 GI Strips - 4 x 0.8 mm) | Km | 153169.19 | 153169.19 | 0.26 | False | None | None | False | None | False | 39823.9894 | 0 | 3332167 | 116760 | None | code528 | Laying of cable in Existing Trench/GI pipe/ Stone Ware/RCC Hume pipe using Wooden/ Aluminum Rollers as directed by the departmental staff with all lead and lifts complete as per specifications and directions of engineer in charge of the work. LT Cable 2.5 to 16 Sqmm | Km | 27110.03 | 27110.03 | 0.26 | False | None | None | False | None | False | 7048.6078 | 0 | 3332168 | 116760 | None | code529 | Fabricating supplying and mounting MS box made out 18SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., with all lead and lifts complete as per specifications and directions of engineer in charge of the work.14SWG | Sq CM | 0.65 | 0.65 | 12000.0 | False | None | None | False | None | False | 7800.0 | 0 | 3332169 | 116760 | None | code530 | Supplying and fixing angle iron frame work fabricated out of MS angle iron..and MS flat…with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint with all lead and lifts complete as per specifications and directions of engineer in charge of the work. 50x50x6mm | Mtr | 512.71 | 512.71 | 10.0 | False | None | None | False | None | False | 5127.1 | 0 | 3332170 | 116760 | None | code531 | Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100V as per IS- 694:2010 with all lead and lifts complete as per specifications and directions of engineer in charge of the work. 3CX2.5sqmm | Mtr | 146.67 | 146.67 | 85.0 | False | None | None | False | None | False | 12466.95 | 0 | 3332171 | 116760 | None | code532 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694: confirming to latest amendments with all lead and lifts complete as per specifications and directions of engineer in charge of the work. 10 sqmm | Mtr | 216.77 | 216.77 | 20.0 | False | None | None | False | None | False | 4335.4 | 0 | 3332172 | 116760 | None | code533 | Supply and erection of 14 Feet Height Street Light Pole 14 Feet Height Street Light Pole on suitable cement concrete foundation with 2.5 Feet height dia 95 mm cast iron decorative round pedestal as per design weighing not less than 37Kgs, the pedestal shall be fitted with Class 'C' G.I.Pipe 7 Feet height 75 mm outer dia and 7 feet height top piece outer dia of 65 mm fixed by measure of threading/ welding/coupling with all lead and lifts complete as per specifications and directions of engineer in charge of the work. (excluding foundation). | Each | 26738.8 | 26738.8 | 10.0 | False | None | None | False | None | False | 267388.0 | 0 | 3332173 | 116760 | None | code534 | Supplying, and fixing of Hot dip Galvanized M.S.Bracket suitable for out door luminaries and mounted on Octagonal pole using necessary bolts, nuts etc., with all lead and lifts complete as per specifications and directions of engineer in charge of the work. Single Arm Bracket with 1000 mm Standard 40/50 mm dia | Each | 2206.6 | 2206.6 | 10.0 | False | None | None | False | None | False | 22066.0 | 0 | 3332174 | 116760 | None | code535 | Supply of LED Streetlight with pressure die cast aluminum housing body with optimal heat sink for better thermal dissipation. Diffuser with Injection moulded & is made of polycarbonate material with high transmission index, delivering superior light output. Rated life Burning Hrs. 50000 hr. @ Lumen Maintenance of 70%. CCT greater than 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire greater than IK08. Power Factor greater than0.9 with mains Current should not be greater than 0.1A to 0.7A & Surge Protection- Min 4 KV along with Over voltage/Overload, short circuit/ miswiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Over load & Short circuit protection ensures reliable operation in spite of problem in output side. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with .... System Power consumption. LED Efficiencygreater than130lm/w at 1W & Fixture Efficiency greater than80lm/w with nominal CRI 75+. housing with supplier word mark / name shall be engraved / Embossing on the die cast housing / body part. . Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Warranty of 5 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED source manufacturer. Suitable for A1/A2 Roads as per IS 1944 Part I & Part II with all lead and lifts complete as per specifications and directions of engineer in charge of the work. LED Streetlight 70 W | Each | 7777.62 | 7777.62 | 10.0 | False | None | None | False | None | False | 77776.2 | 0 | 3332175 | 116760 | None | code536 | Supply and fixing of 4pole power contactor with NO/NC contacts on existing wood/ panel board using necessary bolts, nuts, washers and wiring etc., complete with AC-3 Rating and as per IS-13947) with all lead and lifts complete as per specifications and directions of engineer in charge of the work. 40A | Set | 2930.88 | 2930.88 | 1.0 | False | None | None | False | None | False | 2930.88 | 0 | 3332176 | 116760 | None | code537 | Supplying and fixing Microprocessor based Electronic timer (without contactor, Din Mounting using necessary bolts, nuts and washers etc.,.) 3-120sec setting with all lead and lifts complete as per specifications and directions of engineer in charge of the work. | Set | 2698.54 | 2698.54 | 1.0 | False | None | None | False | None | False | 2698.54 | 0 | 3332177 | 116760 | None | code538 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 with all lead and lifts complete as per specifications and directions of engineer in charge of the work. 6-32 A DP | Each | 959.22 | 959.22 | 4.0 | False | None | None | False | None | False | 3836.88 | 0 | 3332178 | 116760 | None | code539 | Earth work excavation for cable trench of 0.5 to 0.75 Mtr. Width and Depth upto 1 Mtr including trial pits, depositing on bank upto a lead of 50 Mtr, Supplying and Displaying necessary Danger Boards and Lighting, Using sight Rails and Sign Boards at every 100 Mtr wherever necessary as directed with all lead and lifts complete as per specifications and directions of engineer in charge of the work. In ordinary soil | Cum | 340.08 | 340.08 | 41.5 | False | None | None | False | None | False | 14113.32 | 0 | 3332179 | 116760 | None | code540 | KSRB 4-1.6: Providing and Laying in position plain cement cocrente of mix 1:2:4 with Cement @ 240 Kgs, with 20mm and down size graded granite metal coarse aggregates @ 0.878 cum and fine aggregtes @ 0.459 cum machine mixed concrete laid in layers not exceeding 15 cms. thick well compacted, in foundation and plinth and cills, including cost of all materials, labour, HOM of machinery, curing with all lead and lifts complete as per specifications and directions of engineer in charge of the work. A. 6 mtr poles 0.75x0.75x1.5x10 = 8.5 C. Panel boards 1.20x0.50x0.80x1 = 0.48 and for bed 1.5Cmtr | Cum | 8103.41 | 8103.41 | 10.48 | False | None | None | False | None | False | 84923.7368 | 0 | 3332180 | 116760 | None | code541 | KSRB 4.9.1: Providing mild steel reinforcement for RCC work including straightening, cutting, bending, hooking, placing in position, lapping and/or welding wherever required, and Laying with binding wire and anchoring to the adjoining members wherever necessary complete as per design (laps, hooks and wastage shall not be measured and paid)cost of materials labour, HOM of machinery with all lead and lifts complete as per specifications and directions of engineer in charge of the work. 10x15Kg | Kg | 94.75 | 94.75 | 150.0 | False | None | None | False | None | False | 14212.5 | 0 | 3332181 | 116760 | None | code542 | Supply and Fixing of PVC Pipe as per IS-2509 PVC PVC Pipe -25 mm dia 2 mm thick with all lead and lifts complete as per specifications and directions of engineer in charge of the work. | Mtr | 105.14 | 105.14 | 20.0 | False | None | None | False | None | False | 2102.8 | 0 | 3332182 | 116760 | None | code543 | PROVIDING CCTV CAMERAS:
Supply & fixing of Smart Surveillance System (CCTV): using PTZ & Fixed cameras, OFC monitoring system, HMI etc., as per specification with all lead and lifts complete as per specifications and directions of engineer in charge of the work. PTZ Camera Specification: Lens type: Auto focus with Optical Zoom of 30x, Digital Zoom +10x Pan Angle: 360 degree endless Tilt Angle: 210 degree with e-flip or higher Zoom : 30x Optical and 12x Digital Mode :Day and Night Image size: Full HD Streaming: High speed Weather Proof: IP 66 compliant Network Protocol: TCP/IP should be compliant of any other protocol required. Connectivity : Cat 6 / Optical fibre Ethernet: 10Base-T/100Base-TX(RJ45) Power source : both self powered and externally powered | Nos | 87422.9 | 87422.9 | 8.0 | False | None | None | False | None | False | 699383.2 | 0 | 3332183 | 116760 | None | code544 | Supply & fixing of Smart Surveillance System (CCTV): using PTZ & Fixed cameras, OFC monitoring system, HMI etc., as per specification with all lead and lifts complete as per specifications and directions of engineer in charge of the work. Fixed Camera Specifications: Lens type: Bi focal auto iris with 10x digital zoom Mode :Day/Night Image size: 720x486 (NTSC) Streaming: High speed Weather Proof: IP 66 compliant Network Protocol: TCP/IP should be complian of any other protocol required. Connectivity : Cat 6 / Optical fibre Ethernet:10Base t/100Base TX(RJ45) Power source : both self powered and externally powered | No | 15559.13 | 15559.13 | 40.0 | False | None | None | False | None | False | 622365.2 | 0 | 3332184 | 116760 | None | code545 | SUPPLY & ERECTION OF LT PANELS & LIGHTINF FIXTURES:
Supply , Erection, testing & commisioning of LT kiosk 1000A (As per Main Single Line Diagram) with all lead and lifts complete as per specifications and directions of engineer in charge of the work. | Nos. | 184080.0 | 184080.0 | 1.0 | False | None | None | False | None | False | 184080.0 | 0 | 3332185 | 116760 | None | code546 | Supply, Erection, testing & commisioning of Main LT Panel with 14SWG (As per Main Single Line Diagram) with all lead and lifts complete as per specifications and directions of engineer in charge of the work. | Nos. | 109740.0 | 109740.0 | 1.0 | False | None | None | False | None | False | 109740.0 | 0 | 3332186 | 116760 | None | code547 | Supply, Erection, testing & commisioning of APFC (Automaitc Powerfactor correction) Panel-1 with 14SWG 120KVAR (As per Main Single Line Diagram) with all lead and lifts complete as per specifications and directions of engineer in charge of the work. | Nos. | 526752.0 | 526752.0 | 1.0 | False | None | None | False | None | False | 526752.0 | 0 | 3332187 | 116760 | None | code548 | Supply, Erection, testing & commisioning of APFC (Automaitc Powerfactor correction) Panel-2 with 14SWG 60KVAR (As per Main Single Line Diagram) with all lead and lifts complete as per specifications and directions of engineer in charge of the work. | Nos. | 446040.0 | 446040.0 | 1.0 | False | None | None | False | None | False | 446040.0 | 0 | 3332188 | 116760 | None | code549 | Supply, Erection, testing & commisioning of PHE (Public Health Engineering / Plumbing) Panel with 14SWG (As per Main Single Line Diagram) with all lead and lifts complete as per specifications and directions of engineer in charge of the work. | Nos. | 439603.1 | 439603.1 | 1.0 | False | None | None | False | None | False | 439603.1 | 0 | 3332189 | 116760 | None | code550 | Supply, Erection, testing & commisioning of Fire Panel with 14SWG (As per Main Single Line Diagram) with all lead and lifts complete as per specifications and directions of engineer in charge of the work. | Nos | 401648.4 | 401648.4 | 1.0 | False | None | None | False | None | False | 401648.4 | 0 | 3332190 | 116760 | None | code551 | Supply, Erection, testing & commisioning of CA (Common Area) Panel with 14SWG (As per Main Single Line Diagram)with all lead and lifts complete as per specifications and directions of engineer in charge of the work. | Nos. | 507069.6 | 507069.6 | 1.0 | False | None | None | False | None | False | 507069.6 | 0 | 3332191 | 116760 | None | code552 | Supply, Erection, testing & commisioning of Main Lift Panel with 14SWG (As per Main Single Line Diagram) with all lead and lifts complete as per specifications and directions of engineer in charge of the work. | Nos. | 375240.0 | 375240.0 | 1.0 | False | None | None | False | None | False | 375240.0 | 0 | 3332192 | 116760 | None | code553 | Supply, Erection, testing & commisioning of EMG MLDB (Emergency Main lighting DP) with 14SWG (As per Main Single Line Diagram) with all lead and lifts complete as per specifications and directions of engineer in charge of the work. | Nos. | 79085.96 | 79085.96 | 1.0 | False | None | None | False | None | False | 79085.96 | 0 | 3332193 | 116760 | None | code554 | Supply, Erection, testing & commisioning of Lift panel with 14SWG (As per Main Single Line Diagram) with all lead and lifts complete as per specifications and directions of engineer in charge of the work. | Nos. | 95580.0 | 95580.0 | 3.0 | False | None | None | False | None | False | 286740.0 | 0 | 3332194 | 116760 | None | code555 | Supply, Erection, testing & commisioning of Floor panel 250Amps with 14SWG (As per Main Single Line Diagram) with all lead and lifts complete as per specifications and directions of engineer in charge of the work. | Nos. | 236472.0 | 236472.0 | 6.0 | False | None | None | False | None | False | 1418832.0 | 0 | 3332195 | 116760 | None | code556 | Supply, Erection, testing & commisioning of Car charging panel 250Amps with 14SWG (As per Main Single Line Diagram) with all lead and lifts complete as per specifications and directions of engineer in charge of the work. | No | 242844.0 | 242844.0 | 1.0 | False | None | None | False | None | False | 242844.0 | 0 | 3332196 | 116760 | None | code557 | Supply, Erection, testing & commisioningof car charging unit (As per Main Single Line Diagram) with all lead and lifts complete as per specifications and directions of engineer in charge of the work. | No | 16284.0 | 16284.0 | 12.0 | False | None | None | False | None | False | 195408.0 | 0 | 3332197 | 116760 | None | code558 | Supply of Linear Suspended Direct luminaire Pureline slim 50 mm width for Standalone/Continuous installation with efficacy greater than100lm/W System Power 100W CCT 5700 ; CRIgreater than80 Fixed output / DALI driver 140-270V, THDless than10%, PFgreater than0.95, 4KV internal surge protection, EMC/EMI compliant L70B50 @ 50K Hrs.@ 45 Degree Ambient Serviceability Class B Extruded aluminium housing with powder coated/anodized finish with PS diffuser IP 20 LxW 3500x920mm (to match for the table size) (combination of 2 ft - 565x50x75 mm 4ft - 1130x50x75mm 8ft -2260x50x75mm) with all lead and lifts complete as per specifications and directions of engineer in charge of the work. | Nos | 91756.8 | 91756.8 | 4.0 | False | None | None | False | None | False | 367027.2 | 0 | 3332198 | 116760 | None | code559 | Supply of 50/60W 200mm dia suspended decorative light fixture with electronic driver and with 4000K lamps with all lead and lifts complete as per specifications and directions of engineer in charge of the work. | Nos | 17700.0 | 17700.0 | 5.0 | False | None | None | False | None | False | 88500.0 | 0 | 3332199 | 116760 | None | code560 | Supply of 30/40W 400MM/500MM dia suspended decorative light fixture with electronic driver and with 4000K lamps with all lead and lifts complete as per specifications and directions of engineer in charge of the work. | Nos | 4389.6 | 4389.6 | 50.0 | False | None | None | False | None | False | 219480.0 | 0 | 3332200 | 116760 | None | code561 | Supply of 40W 200mm down linear light fixture with Dimmemable Driver with 4000K with all lead and lifts complete as per specifications and directions of engineer in charge of the work | No | 24780.0 | 24780.0 | 16.0 | False | None | None | False | None | False | 396480.0 | 0 | 3332201 | 116760 | None | code562 | Supply of 11W FTL Mirror Light with all lead and lifts complete as per specifications and directions of engineer in charge of the work. | No | 877.92 | 877.92 | 45.0 | False | None | None | False | None | False | 39506.4 | 0 | 3332202 | 116760 | None | code563 | Supply and installation of IP20 Class, Occupency switch ceiling mount occupancy detection range of 5M recessed and controlled LED load of 6A with inbuilt photos and rotory nobs on the front cover of sensor to set the Lux level and time dealy from 30Sec-30Min and an inbuilt retrackable shield to reduce the sensor range. the occupency switch shall not consume more than 1.2 watts of power and complies to IEC (EN) 60669: 2:1 with all lead and lifts complete as per specifications and directions of engineer in charge of the work. | No | 5304.1 | 5304.1 | 100.0 | False | None | None | False | None | False | 530410.0 | 0 | 3332203 | 116760 | None | code564 | Supply of 6 zone AV touch panel with all lead and lifts complete as per specifications and directions of engineer in charge of the work. | No | 31152.0 | 31152.0 | 2.0 | False | None | None | False | None | False | 62304.0 | 0 | 3332204 | 116760 | None | code565 | Supply and laying DWC Pipe 50mm outer dia with all lead and lifts complete as per specifications and directions of engineer in charge of the work. | Mtr | 64.9 | 64.9 | 240.0 | False | None | None | False | None | False | 15576.0 | 0 | 3332205 | 116760 | None | code566 | Supply of 6 zone AV touch panel with all lead and lifts complete as per specifications and directions of engineer in charge of the work. | No | 31152.0 | 31152.0 | 2.0 | False | None | None | False | None | False | 62304.0 | 0 | 3332206 | 116760 | None | code567 | Providing Laminated Single line diagram (SLD) for all HT/LT panels for MS building of KIADB along with wiring as built drawings with all lead and lifts complete as per specifications and directions of engineer in charge of the work. | No | 2224.3 | 2224.3 | 6.0 | False | None | None | False | None | False | 13345.8 | 0 |
|