1718956267000 | 0 | None | None | Other Works | Construction of cotinues work of primary school of teachers assosiation at ward no.03, dharwad. | 840541.71 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3324876 | 116488 | None | 7.28.1 | Providing & fixing 10 mm thick plaster of Paris (gypsum anhydrous) ceiling up to a height of 5 m above floor level, over first class kail wood strips 25x6 mm with 10 mm gap in between and reinforced with rabbit wire mesh fixed to wooden frame. Flat surfaces. (PWD SR 2023-24 Vol No.02 P.No.28 SI No.7.28.1) | Sqm | 1337.7 | 1337.7 | 118.41 | False | None | None | False | None | False | 158397.057 | 0 | 3324877 | 116488 | None | 20.12 | Raking out joints in lime or cement mortar and preparing the surface for re-pointing or replastering, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge. (PWD SR 2023-24 Vol No.02 P.No.198 SI No.20.12) | Sqm | 52.5 | 52.5 | 149.4 | False | None | None | False | None | False | 7843.5 | 0 | 3324878 | 116488 | None | 8.1.1 | Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (PWD SR 2023-24 Vol No.02 P.No.41 SI No.8.1.1) | Sqm | 267.75 | 267.75 | 149.4 | False | None | None | False | None | False | 40001.85 | 0 | 3324879 | 116488 | None | 8.39 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (PWD SR 2023-24 Vol No.02 P.No.48 SI No.8.39) | Sqm | 133.35 | 133.35 | 688.92 | False | None | None | False | None | False | 91867.482 | 0 | 3324880 | 116488 | None | 9.34 | Flooring with 25mm thick polished tandur blue stone slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab, including cost of materials, labour, curing, polishing complete as per specifications. (PWD SR 2023-24 Vol No.02 P.No.64 SI No.9.34) | Sqm | 1622.25 | 1622.25 | 33.49 | False | None | None | False | None | False | 54329.1525 | 0 | 3324881 | 116488 | None | 11.26.1 | Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. M.S. tube including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (PWD SR 2023-24 Vol No.02 P.No.82 SI No.11.26.1) | Kg | 144.9 | 144.9 | 141.75 | False | None | None | False | None | False | 20539.575 | 0 | 3324882 | 116488 | None | 1.4.1 | Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m (PWD SR 2023-24 Vol No.01 P.No.05 SI No.1.4.1) | Cum | 254.1 | 254.1 | 1.44 | False | None | None | False | None | False | 365.904 | 0 | 3324883 | 116488 | None | 2.1.2 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. (PWD SR 2023-24 Vol No.01 P.No.15 SI No.2.1.2) | Cum | 5947.2 | 5947.2 | 0.22 | False | None | None | False | None | False | 1308.384 | 0 | 3324884 | 116488 | None | 2.2.2 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.(PWD SR 2023-24 Vol No.01 P.No.15 SI No.2.2.2) | Cum | 6560.4 | 6560.4 | 1.296 | False | None | None | False | None | False | 8502.2784 | 0 | 3324885 | 116488 | None | 2.11a | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Buildings(PWD SR 2023-24 Vol No.01 P.No.18 SI No.2.11a)Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Buildings(PWD SR 2023-24 Vol No.01 P.No.18 SI No.2.11a) | Tonne | 93929.85 | 93929.85 | 0.165 | False | None | None | False | None | False | 15498.42525 | 0 | 3324886 | 116488 | None | 2.5.1 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coars aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical
specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (PWD SR 2023-24 Vol No.01 P.No.16 SI No.2.5.1) | Cum | 6961.5 | 6961.5 | 0.585 | False | None | None | False | None | False | 4072.4775 | 0 | 3324887 | 116488 | None | 11.16.1 | Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (PWD SR 2023-24 Vol No.02 P.No.82 SI No.11.16.1) | Kg | 142.8 | 142.8 | 570.3 | False | None | None | False | None | False | 81438.84 | 0 | 3324888 | 116488 | None | 7.1.1 | Providing & fixing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete as per design drawings (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required as per the direction of Engineer in charge, 0.63 mm thick with zinc coating not less than 275 g/ m² (PWD SR 2023-24 Vol No.02 P.No.21 SI No.7.1.1) | Sqm | 922.95 | 922.95 | 60.18 | False | None | None | False | None | False | 55543.131 | 0 | 3324889 | 116488 | None | 8.33.3 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90L/10 m² over an under coat of primer applied @ 0.80 L/10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (PWD SR 2023-24 Vol No.02 P.No.47 SI No.8.33.3) | Sqm | 145.95 | 145.95 | 29.72 | False | None | None | False | None | False | 4337.634 | 0 | 3324890 | 116488 | None | 8.51 | Providing and applying white cement based putty of average thickness1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. (PWD SR 2023-24 Vol No.02 P.No.50 SI No.8.51) | Sqm | 105.5 | 105.5 | 118.41 | False | None | None | False | None | False | 12492.255 | 0 | 3324891 | 116488 | None | 8.54.2 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 g/L of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge. (PWD SR 2023-24 Vol No.02 P.No.50 SI No.8.54.2) | Sqm | 115.5 | 115.5 | 626.79 | False | None | None | False | None | False | 72394.245 | 0 | 3324892 | 116488 | None | 9.6.2 | Providing and laying Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand) Medium shade pigment using 50% white cement 50% Grey cement (PWD SR 2023-24 Vol No.02 P.No.59, SI No.9.6.2) | Sqm | 1251.6 | 1251.6 | 43.4 | False | None | None | False | None | False | 54319.44 | 0 | 3324893 | 116488 | None | 17.50 | Providing and fixing factory made precast RCC perforated drain covers, having concrete of strength not less than M-25, of size 1000 x 450x50 mm, reinforced with 8 mm dia four nos longitudinal & 9 nos cross sectional T.M.T. hoop bars, including providing 50 mm dia perforations @ 100 to 125 mm c/c, including providing edge binding with M.S. flats of size 50 mm x 1.6 mm complete, all as per direction of Engineer-in-charge. (PWD SR 2023-24 Vol No.02 P.No.175, SI No.17.5) | Sqm | 1179.15 | 1179.15 | 25.0 | False | None | None | False | None | False | 29478.75 | 0 | 3324894 | 116488 | None | 6.31 | Providing and laying autoclaved aerated cement blocks masonry with 150mm/230mm/300 mm thick AAC blocks as per IS 2185 (Part III) in super structure above plinth level up to floor I level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. (PWD SR 2023-24 Vol No.02 P.No.17, SI No.6.31) | Sqm | 8376.9 | 8376.9 | 2.978 | False | None | None | False | None | False | 24946.4082 | 0 | 3324895 | 116488 | None | 12.54 | Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge. (PWD SR 2023-24 Vol No.02 P.No.104, SI No.12.54) | Sqm | 333.9 | 333.9 | 11.4 | False | None | None | False | None | False | 3806.46 | 0 | 3324896 | 116488 | None | 12.55.2 | Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges. -do- with one side prelam. (PWD SR 2023-24 Vol No.02 P.No.104, SI No.12.55.2) | Sqm | 2142.0 | 2142.0 | 3.15 | False | None | None | False | None | False | 6747.3 | 0 | 3324897 | 116488 | None | 8.3.1 | Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge (PWD SR 2023-24 Vol No.02 P.No.41, SI No.8.3.1) | Sqm | 371.7 | 371.7 | 18.85 | False | None | None | False | None | False | 7006.545 | 0 | 3324898 | 116488 | None | 8.5.1. | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix 1:3 (1 cement: 3 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (PWD SR 2023-24 Vol No.02 P.No.42, SI No.8.5.1) | Sqm | 384.3 | 384.3 | 22.75 | False | None | None | False | None | False | 8742.825 | 0 | 3324899 | 116488 | None | 9.38 | Providing skirting, dadooing, rises of steps with white glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. (PWD SR 2023-24 Vol No.02 P.No.65, SI No.9.38) | Sqm | 1461.6 | 1461.6 | 10.95 | False | None | None | False | None | False | 16004.52 | 0 | 3324900 | 116488 | None | 9.11 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. (PWD SR 2023-24 Vol No.02 P.No.60, SI No.9.11) | Sqm | 933.45 | 933.45 | 3.9 | False | None | None | False | None | False | 3640.455 | 0 | 3324901 | 116488 | None | 8.74.1 | Finishing walls with Acrylic Smooth exterior paint of required shade : Old work (Two coat applied @ 1.67 l/ 10 m²) on existing cement paint surface including preparing the surface after thoroughly cleaning the surface to remove all dirt, dust and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge (PWD SR 2023-24 Vol No.02 P.No.53, SI No.8.74.1) | Sqm | 110.25 | 110.25 | 20.5 | False | None | None | False | None | False | 2260.125 | 0 | 3324902 | 116488 | None | 14.3.1 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required W.C. pan with ISI marked white solid plastic seat and lid (PWD SR 2023-24 Vol No.02 P.No.131, SI No.14.3.1) | Nos | 6275.85 | 6275.85 | 2.0 | False | None | None | False | None | False | 12551.7 | 0 | 3324903 | 116488 | None | 13.31.3 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall (PWD SR 2023-24 Vol No.02 P.No.122, SI No.13.31.3) | Nos | 333.9 | 333.9 | 30.0 | False | None | None | False | None | False | 10017.0 | 0 | 3324904 | 116488 | None | 3.6.4 | Stepped Fan Regulator. Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.
3.6.4)Stepped Fan Regulator Two Module
PWD Elct, SR 2023-24 Page No. 7 IItem code 3.6.4 . | Nos | 357.0 | 357.0 | 7.0 | False | None | None | False | None | False | 2499.0 | 0 | 3324905 | 116488 | None | 11.3.2 | LED Tube Fitting
Supplying of .feet PVC Batten with integrated LED tube . W with high quality diffuser with Life of 25000 burning hours & 70 lumen maintenance with CRI 80. Power Input: 220240V@ 50 60Hz & Power factor 0.9 along with CE approved. 2years Warranty against any manufacturing defect working under standard electrical condition.
11.3.2) LED light fighting 1 x4'- 20 22 w
PWD, Elct, SR 2023-24 Page No.34 IItem code 11.3.2 . | Nos | 690.0 | 690.0 | 8.0 | False | None | None | False | None | False | 5520.0 | 0 | 3324906 | 116488 | None | 13.7.1 | LED Fitting fixing Charges
Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling / rafters /girders using 23/0.0076" twin twisted PVC insulated wires,required Nos of round blocks and clamps. 13.7.1) On wall / ceiling / Rafter / Girders
PWD,Elct, SR 2023-24 Page No. 55 IItem code 13.7.1 | Nos | 122.0 | 122.0 | 8.0 | False | None | None | False | None | False | 976.0 | 0 | 3324907 | 116488 | None | 6.3.1 | Supplying capacitor type ceiling fan complete with down rod blades,shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system.(BLDC fans)Page No. 29 IItem code6.3.1 PWD,Elct, SR 2023-24. | Nos | 2984.0 | 2984.0 | 7.0 | False | None | None | False | None | False | 20888.0 | 0 | 3324908 | 116488 | None | 13.11 | Fan Fixing Charges Fixing a ceiling /wall mounting fan of all capacities and all types,with necessary clamps and 'S' hook made out of 15mm dia MS rod,with 5 A. ceiling rose of approved quality with necessary length of 23/0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size wooden board and wired. Page No. 56 IItem code13.11 PWD,Elct, SR 2023-24. | Nos | 315.0 | 315.0 | 7.0 | False | None | None | False | None | False | 2205.0 | 0 |
|