createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1718784449132
version6
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee2500.00
emd169300.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose10-07-2024 17:00:00
tenderQueryClose09-07-2024 11:00:00
technicalBidOpen12-07-2024 11:00:00
publishedDate24-06-2024 11:27:40
publishedByPostCMC_MCOM_CNP
publishedByUserKPE13446 - C PUTTASWAMY
bidValidityPeriod90
noOfCalls1
preBidMeetingDate02-07-2024 11:00:00
preBidMeetingYnTrue
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonJayanna M R
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumberNone
mobileNumber9844574499
tenderSupplierListNone
tenderSchedule
createdTs1718784449194
version6
createdDateNone
modifiedDateNone
tenderNumberDMA/2024-25/BD/WORK_INDENT18904
titleConstruction of Proposed 10TPD MRF Centre (Material Recovery Facility Primary and Secondary Shed) of PEB Structure in SWM LAND at CHANNAPATNA CMC limits
descriptionConstruction of Proposed 10TPD MRF Centre (Material Recovery Facility Primary and Secondary Shed) of PEB Structure in SWM LAND at CHANNAPATNA CMC limits
categoryWORKS
categoryTextWorks
ecv9989786.07
deptNameDirectorate of Municipal Administration
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnTrue
location2386
locationNameDMA City Municipal Council Channapattna
provisionalAmount9990000.0
groupOverheadTotal1525300.0
fileNumberCMC/CPT/MRFSHED/01/2024-251
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17187844490000NoneNoneBuildingsConstruction of Proposed 10TPD MRF Centre (Material Recovery Facility Primary and Secondary Shed) of PEB Structure in SWM LAND at CHANNAPATNA CMC limits8464486.07
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3309665115556Nonecode01Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. (Item No. 1.14.1 Page No. 8 Vol.1 PWD SR)Cum105.06105.0692.0FalseNoneNoneFalseNoneFalse9665.520
3309666115556Nonecode02Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates (The cost of steel reinforcement & formwork shall be paid separately. Specification No. KBS 2.1, (Item No. 2.1.2 Page No. 15 Vol.1 PWD SR)Cum5833.925833.9290.01FalseNoneNoneFalseNoneFalse525111.13920
3309667115556Nonecode03Providing and laying in position cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes ,labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately). M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Specification No. KBS 2.3., 2.3 (Item No. 2.3.2 Page No. 16 Vol.1 PWD SR & Appendix I page No.115)Cum7192.87192.824.16FalseNoneNoneFalseNoneFalse173778.0480
3309668115556Nonecode04Providing and laying in position cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes ,labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately). M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Specification No. KBS 2.3., 2.3 (Item No. 2.3.2 Page No. 16 Vol.1 PWD SR & Appendix I page No.115)Cum11210.411210.49.21FalseNoneNoneFalseNoneFalse103247.7840
3309669115556Nonecode05Providing and laying in position cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes ,labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately). M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Specification No. KBS 2.3., 2.3 (Item No. 2.3.2 Page No. 16 Vol.1 PWD SR & Appendix I page No.115)Cum7192.87192.8106.21FalseNoneNoneFalseNoneFalse763947.2880
3309670115556Nonecode06Providing and laying in cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately). M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Item No. 2.2.3 Page No. 15 Vol.1 PWD SR & Appendix I page No.115)Cum9694.089694.0810.71FalseNoneNoneFalseNoneFalse103823.59680
3309671115556Nonecode07Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification .(Item No. 2.11 Page No. 18 Vol.1 PWD SR)Tonne92140.7192140.718.7568FalseNoneNoneFalseNoneFalse806857.7693280
3309672115556Nonecode08Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) . (Item No. 5.4 Page No. 9 Vol.2 PWD SR)Cum6580.676580.6741.793FalseNoneNoneFalseNoneFalse275025.941310
3309673115556Nonecode09Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,allmaterials,usage& all other appurtenaces required to complete the work (Item No. 1.8 Page No. 7 Vol.1 PWD SR)Cum488.22488.22523.12FalseNoneNoneFalseNoneFalse255397.64640
3309674115556Nonecode10Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. (Item No. 6.33 Page No. 17 Vol.2 PWD SR)Sqm1267.931267.93274.416FalseNoneNoneFalseNoneFalse347940.278880
3309675115556Nonecode11Providing 15mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(Item No. 8.2.1, Page No. 41, Vol.2)Sqm303.85303.85597.205FalseNoneNoneFalseNoneFalse181460.739250
3309676115556Nonecode12Providing and fixing Structural Steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-inCharge. (Item No. 11.2, Page No. 77, Vol.2)Kgs116.39116.3927260.0FalseNoneNoneFalseNoneFalse3172791.40
3309677115556Nonecode13Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05 %) total coated thickness with zinc coating 120 g/m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineerin-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. (Item No. 7.38, Page No. 26, Vol.2)Sqm585.04585.041623.508FalseNoneNoneFalseNoneFalse949817.120320
3309678115556Nonecode14Finishing with Deluxe Multi surface paint system for interiors and exteriors using pirmer as per manufactures specifications: Two coats applied on walls @1.25L/10sqm over and including one coat of special primer applied @0.75L/10sqm with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge (The gloss should be 50% @ 60 degree angle with 10 years life) (I.no:8.33.1, Pg.no:46, Vol-2)Sqm162.74162.74599.37FalseNoneNoneFalseNoneFalse97541.47380
3309679115556Nonecode15Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (Item No. 11.6.1, Page No. 76, Vol.2)Sqm2711.992711.9933.75FalseNoneNoneFalseNoneFalse91529.66250
3309680115556Nonecode16Extra for providing 2 HP Mild Steel Auto Reverse Shutter Gearbox for operating rolling shutters including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.(Item No. 11.8.4, Page No. 79, Vol.2)No25426.5825426.582.0FalseNoneNoneFalseNoneFalse50853.160
3309681115556Nonecode17Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For Fixed Portion: Powder coated aluminium (minimum thickness of powder coating 50 micron) including cost of materials, labour, usage charges of machinery complete as per specifications..(Item No. 11.35.1.1, Page No. 87, Vol.2)Kgs465.56465.56480.0FalseNoneNoneFalseNoneFalse223468.80
3309682115556Nonecode18Painting steel work with Deluxe Multi surfce paint to give an even shade. Two cot applied @ 0.9L/10sqm over an under coat of primer applie @0.80L/10sqm of approved brand and manufacture including preparing the surface after throughly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge (I.N0:8.33.3, Pg.no:47, Vol-2)Sqm143.17143.1774.25FalseNoneNoneFalseNoneFalse10630.37250
3309683115556Nonecode19Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws,bolts,nuts,necessary phase separators,handle and wiring complete.Protection of Overload and Short circuit with adjustable thermal magnetic release,Microprocessor release shall have Earth Fault as per IS/IEC60947-2. (Icu=100%lcs).In 4P MCCB,all Poles should have protection for Short-Cicrcuit/OverLoad.For Microprocessor MCCB S Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open).Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. (P.No.17, I.No.5.15.1 in CSR Electrical SR Volume-6 2023-24)Each6268.586268.583.0FalseNoneNoneFalseNoneFalse18805.740
3309684115556Nonecode20Four Pole-100 A 25 kA (P.No.17, I.No.5.15.9 in CSR Electrical SR Volume-6 2023-24)Each8741.618741.611.0FalseNoneNoneFalseNoneFalse8741.610
3309685115556Nonecode21Supplying and fixing of Modular MCB Devices (Tripper) With Breaking capacity of 6kA.16-32 A SP (P.No.21, I.No.5.46.1 in CSR Electrical SR Volume-6 2023-24)Each216.3216.36.0FalseNoneNoneFalseNoneFalse1297.80
3309686115556Nonecode2263 A TP (P.No.21, I.No. 5.46.6 in CSR Electrical SR Volume-6 2023-24)Each1230.851230.858.0FalseNoneNoneFalseNoneFalse9846.80
3309687115556Nonecode23Supplying.........A rated 3 phase with neutral busbar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve,mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board.The busbar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete.(P.No.20, I.No.5.40.1 in CSR Electrical SR Volume-6 2023-24) 100 A 4 x 30 x 6 mm Aluminium StripsMtr2538.952538.9510.0FalseNoneNoneFalseNoneFalse25389.50
3309688115556Nonecode24Supplying and fixing angle iron frame work fabricated out of M.S.angle iron..and M.S.Flat......with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint.(P.No.20, I.No.5.41.1 in CSR Electrical SR Volume-6 2023-24) 40 x 40 x 6 mmMtr314.15314.156.0FalseNoneNoneFalseNoneFalse1884.90
3309689115556Nonecode25Fabricating supplying and mounting MS box made out....SWG suitable for floor/wall mounting,fully weather proof with provision for better heat dissipation,provided with hinged front cover,equipped with tamper proof locking arrangements,with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7 tanks treatment with powder coated paint and finally finished with approved colour etc., complete.(P.No.20, I.No.5.42.1 in CSR Electrical SR Volume-6 2023-24)Sqm0.510.5135000.0FalseNoneNoneFalseNoneFalse17850.00
3309690115556Nonecode26Supply and fixing of 3pole power contactor with NO/NC contacts on existing wood/panel board using necessary bolts,nuts,washers and wiring etc., complete with AC-3 Rating and as per IS-13947.(P.No.15 , I.No.5.13.1 in CSR Electrical SR Volume-6 2023-24)Each1328.71328.79.0FalseNoneNoneFalseNoneFalse11958.30
3309691115556Nonecode27Supplying and fixing Micro processor Based Astro nomical timer Switch with using necessary bolts, nuts and washers.(P.No.21, I.No.5.48 in CSR Electrical SR Volume-6 2023-24)Each4988.294988.293.0FalseNoneNoneFalseNoneFalse14964.870
3309692115556Nonecode28Supply and fixing of Auxiliary contactor relay with 2 NO and 2 NC contact and operating coil voltage of 220V to 260V. fixed on existing wood/panel board using necessary bolts, nuts, washers and wiring etc.,(P.No.22, I.No.5.53 in CSR Electrical SR Volume-6 2023-24)Each1369.91369.93.0FalseNoneNoneFalseNoneFalse4109.70
3309693115556Nonecode29Supplying and fixing of metal clad industrial plugs and sockets. (P.No.9, I.No.3.13.3 in CSR Electrical SR Volume-6 2023-24) 3pole+earth 440V PLUG-32 AmpsEach465.69465.692.0FalseNoneNoneFalseNoneFalse931.380
3309694115556Nonecode3032 Amps (P.No.9, I.No.3.13.4 in CSR Electrical SR Volume-6 2023-24)Each628.15628.152.0FalseNoneNoneFalseNoneFalse1256.30
3309695115556Nonecode31Supplying,fixing and wiring 0to30 A Direct Reading AC analog type Ammeter.(P.No.18, I.No.5.24 in CSR Electrical SR Volume-6 2023-24)Each478.95478.954.0FalseNoneNoneFalseNoneFalse1915.80
3309696115556Nonecode32Supplying,fixing and wiring 0 to 600 V 96x96mm AC Voltmeter on existing panel/wood board.(P.No.18, I.No.5.22 in CSR Electrical SR Volume-6 2023-24)Each465.56465.561.0FalseNoneNoneFalseNoneFalse465.560
3309697115556Nonecode33Supplying,fixing and wiring rotary selector switch suitable for Ammeter.(P.No.19, I.No.5.27 in CSR Electrical SR Volume-6 2023-24)Each206.0206.04.0FalseNoneNoneFalseNoneFalse824.00
3309698115556Nonecode34Supplying, fixing and wiring rotary selector switch suitable for Voltmeter.(P.No.19, I.No.5.28 in CSR Electrical SR Volume-6 2023-24)Each164.8164.81.0FalseNoneNoneFalseNoneFalse164.80
3309699115556Nonecode35Supplying,fixing and wiring 50/5 to 400/5A 5VA burden Current Transformer Class 0.5 accuracy with Tape Wound.(P.No.19, I.No.5.34 in CSR Electrical SR Volume-6 2023-24)Each578.86578.864.0FalseNoneNoneFalseNoneFalse2315.440
3309700115556Nonecode36Supplying and fixing digital frequency meter with latest micro controller technology,ultra bright 4digit LED display,from 30-500VAC and optional or relay output for high/low frequency and wiringcomplete.(P.No.19, I.No.5.32 in CSR Electrical SR Volume-6 2023-24)Each1004.251004.251.0FalseNoneNoneFalseNoneFalse1004.250
3309701115556Nonecode37Supplying,fixing and wiring heavy duty low voltage capacitors conforming to IS2834.3 phase,400/440V grade,for power factor improvement of rotating machineries like induction motor.(P.No.19, I.No.5.37 in CSR Electrical SR Volume-6 2023-24)Kvar494.4494.45.0FalseNoneNoneFalseNoneFalse2472.00
3309702115556Nonecode381.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975. ESCOM SR 2023-24 I No. 32.11 Pg.13 3.5Cx50 Sqmm Al Ar cable ESCOM SR 2023-24 I No. 32.11 Pg.13Km184342.19184342.190.03FalseNoneNoneFalseNoneFalse5530.26570
3309703115556Nonecode394Cx25 Sqmm Al Ar cable.ESCOM SR 2023-24 I No. 32.08 Pg.13Km185239.32185239.320.02FalseNoneNoneFalseNoneFalse3704.78640
3309704115556Nonecode404Cx16 Sqmm Al Ar cable ESCOM SR 2023-24 I No. 32.05 Pg.13Km146097.26146097.260.02FalseNoneNoneFalseNoneFalse2921.94520
3309705115556Nonecode414Cx10 Sqmm Cu Ar cable.ESCOM SR 2023-24 I No. 32.03 Pg.13Km121544.12121544.120.02FalseNoneNoneFalseNoneFalse2430.88240
3309706115556Nonecode42Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 2.5 to 25 sqmm ESCOM SR 2023-24 I No. 21.05 Pg.52Km21512.5821512.580.06FalseNoneNoneFalseNoneFalse1290.75480
3309707115556Nonecode4335 to 95 Sqmm .ESCOM SR 2023-24 I No. 21.06 Pg.52Km32073.1732073.170.03FalseNoneNoneFalseNoneFalse962.19510
3309708115556Nonecode44Earth Work Excavation for pipeline/cables by manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shorting, strutting,barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting and stacking the selected earth for reuse in a redius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth sides of foundations etc.. in layers not exceeding 20 cm in depth, consolidated each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work.(P.No.06, I.No 1.6.1 in KPWD CSR volume-1, 2023-24Cum498.52498.526.75FalseNoneNoneFalseNoneFalse3365.010
3309709115556Nonecode45Cable Joint and wiring (for HT & LT UG Cable). LT UG Cable. Heat shrinkable Type Terminations ESCOM SR 2023-24 I No. 22.13 Pg.53Set195.7195.72.0FalseNoneNoneFalseNoneFalse391.40
3309710115556Nonecode4635 to 95 Sqmm .ESCOM SR 2023-24 I No. 22.14 Pg.53Set96.8296.8212.0FalseNoneNoneFalseNoneFalse1161.840
3309711115556Nonecode47Supplying & Fixing heavy guage PVC conduit type 2mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc, and shall be concealed in wall/RCC slab or exposed on fixing invrted wood plugs in case of RCC ceiling and RCC wall/stone structure or rawl plugs in case of brick wall & cement plastering the damaged portion using heavy gauage saddles at interval of 700mm using NF screws. PWD Electrical SR-2023-24, ITEM NO:1.1 ,CH-1, PAGE NO-2 19/20mm dia PVC 2mm thick conduit.PWD Electrical SR-2023-24, ITEM NO:1.1.1 ,CH-1, PAGE NO-2Mtr71.0771.0725.0FalseNoneNoneFalseNoneFalse1776.750
3309712115556Nonecode4825mm dia PVC 2mm thick conduit.PWD Electrical SR-2023-24, ITEM NO:1.1.2 ,CH-1, PAGE NO-2Mtr83.4383.4325.0FalseNoneNoneFalseNoneFalse2085.750
3309713115556Nonecode4932mm dia PVC 2.5mm thick conduit.PWD Electrical SR-2023-24, ITEM NO:1.1.3 ,CH-1, PAGE NO-2Mtr109.18109.1820.0FalseNoneNoneFalseNoneFalse2183.60
3309714115556Nonecode5040mm dia PVC 2.5mm thick conduit.PWD Electrical SR-2023-24, ITEM NO:1.1.4 ,CH-1, PAGE NO-2Mtr153.47153.4720.0FalseNoneNoneFalseNoneFalse3069.40
3309715115556Nonecode51Supplying and wiring adopting loop system in existing PVC Conduit/casing capping using 2x1.5 Sqmm (Phase&Neutral) & 1x1.0 sqmm (Earthwire) FRLS multistrand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gangbox, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. PWD Electrical SR-2023-24, ITEM NO:2.1,CH-1, PAGE NO-5 Short point upto 3Mtr from tapping point to out let via switch. PWD Electrical SR-2023-24, ITEM NO:2.1.1 ,CH-1, PAGE NO-5No293.55293.5510.0FalseNoneNoneFalseNoneFalse2935.50
3309716115556Nonecode52Medium point above 3Mtr upto 6Mtr from tapping point to outlet via switch .PWD Electrical SR-2023-24, ITEM NO:2.1.2 ,CH-1, PAGE NO-5No405.82405.8210.0FalseNoneNoneFalseNoneFalse4058.20
3309717115556Nonecode53Long point above 6Mtr upto 10Mtr from tapping point to out let via switch.PWD Electrical SR-2023-24, ITEM NO:2.1.3 ,CH-1, PAGE NO-5No587.1587.16.0FalseNoneNoneFalseNoneFalse3522.60
3309718115556Nonecode54Two outlet in a row, above 3Mtr upto 6Mtr from tapping point to outlet via switches.PWD Electrical SR-2023-24, ITEM NO:2.1.4 ,CH-1, PAGE NO-5No729.24729.245.0FalseNoneNoneFalseNoneFalse3646.20
3309719115556Nonecode55Three outlet in a row, above 6Mts upto 10Mtr from tapping point to out let via switches.PWD Electrical SR-2023-24, ITEM NO:2.1.5 ,CH-1, PAGE NO-5No1066.051066.054.0FalseNoneNoneFalseNoneFalse4264.20
3309720115556Nonecode56Wiring for lighting /power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010. PWD Electrical SR-2023-24, ITEM NO:2.3 ,CH-1, PAGE NO-51.0 Sqmm Cu FRLS wire.PWD Electrical SR-2023-24, ITEM NO:2.3.1 ,CH-1, PAGE NO-5Mtr19.5719.57200.0FalseNoneNoneFalseNoneFalse3914.00
3309721115556Nonecode571.5 Sqmm Cu FRLS wire.PWD Electrical SR-2023-24, ITEM NO:2.3.2 ,CH-1, PAGE NO-5Mtr26.7826.78100.0FalseNoneNoneFalseNoneFalse2678.00
3309722115556Nonecode582.5 Sqmm Cu FRLS wire.PWD Electrical SR-2023-24, ITEM NO:2.3.3 ,CH-1, PAGE NO-5Mtr43.2643.26150.0FalseNoneNoneFalseNoneFalse6489.00
3309723115556Nonecode594.0 Sqmm Cu FRLS wire.PWD Electrical SR-2023-24, ITEM NO:2.3.4 ,CH-1, PAGE NO-5Mtr64.8964.8975.0FalseNoneNoneFalseNoneFalse4866.750
3309724115556Nonecode606.0 Sqmm Cu FRLS wire.PWD Electrical SR-2023-24, ITEM NO:2.3.5 ,CH-1, PAGE NO-5Mtr94.7694.7650.0FalseNoneNoneFalseNoneFalse4738.00
3309725115556Nonecode61Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos.of machine screws, bolts nuts etc.,complete on the existing metal/PVC box. 10 - 12 Module Polycarbonate switch box plate.PWD Electrical SR-2023-24, ITEM NO:3.5.6 ,CH-3, PAGE NO-8No354.32354.325.0FalseNoneNoneFalseNoneFalse1771.60
3309726115556Nonecode623 Module Polycarbonate switch box plate.PWD Electrical SR-2023-24, ITEM NO:3.5.2 ,CH-3, PAGE NO-5No165.83165.834.0FalseNoneNoneFalseNoneFalse663.320
3309727115556Nonecode63Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cuttingin Brick/C.C wall, including necessary rawl plugs,Machine/NF screws etc., complete.No127.72127.725.0FalseNoneNoneFalseNoneFalse638.60
3309728115556Nonecode6410-12 Way PWD Electrical SR-2023-24, ITEM NO:3.3.6 ,CH-3, PAGE NO-8No268.83268.835.0FalseNoneNoneFalseNoneFalse1344.150
3309729115556Nonecode65Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.Switches & sockets outlets in Existing modular box. PWD Electrical SR-2023-24, ITEM NO:3.6 ,CH-3, PAGE NO-9No105.06105.064.0FalseNoneNoneFalseNoneFalse420.240
3309730115556Nonecode666A 3 way socket.PWD Electrical SR-2023-24, ITEM NO:3.6.3 ,CH-3, PAGE NO-9No176.13176.134.0FalseNoneNoneFalseNoneFalse704.520
3309731115556Nonecode676/16A Universal socket.PWD Electrical SR-2023-24, ITEM NO:3.6.10 ,CH-3, PAGE NO-9No243.08243.082.0FalseNoneNoneFalseNoneFalse486.160
3309732115556Nonecode68Supply & fixing of LED flood light luminaire with pressure die cast aluminium housing body for optimal thermal dissipation.Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate clear glass material,delivering superior light output Rated life Burning Hrs 50000hr Lumen Maintenance of optical and electrical compartment impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection Min 5KV along with Over voltage Overload short circuit miss wiring protection.Compatible for pole mauling with outer dia of 40 mm to 50mm.Universal Voltage driver to operate wide voltage range from 100 V to 270V 50/60 Hz application Compliance to IS 10322 IEC60598 ,LM79 LM80 Adherence with RoHS.UL approved MCPCB.Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools.LED Light fixture with. System Power consumption.LED Efficiency 1301m w, nominal CRI 75.Luminaire manufacturer should have in-house facility accredited by NABL/CPRI any Government certified agency & Design &Development facility certified by ISO 9001:2008.Housing with supplier wordmark/name shall be Engraved/Embossing on the die cast housing/Body part Warranty of 2 Years against any manufacturing defect working understand ard electrical conditions as mentioned above should be given by LED manufacturer &Cree/Nichia/Lumileds/Osram make LED Source. LED flood light 100W PWD Electrical SR-2023 24, ITEM NO:11.9.2No9770.589770.5810.0FalseNoneNoneFalseNoneFalse97705.80
3309733115556Nonecode69GI/Copper strips for grounding connections, using necessary fixing materials as required.25x3mm GI Strip.PWD Electrical SR-2023-24, ITEM NO:12.58.2 ,CH-12, PAGE NO-54Mtr84.4684.4640.0FalseNoneNoneFalseNoneFalse3378.40
3309734115556Nonecode702 mm thick perforated cable GI tray with one xisting MS angle support using necessary GI bolts/nuts and washer or welding as required.(PWD Electrical SR-2023-24, ITEM NO:12.59.2 ,CH-12, PAGE NO-55Mtr604.61604.6115.0FalseNoneNoneFalseNoneFalse9069.150
3309735115556Nonecode71Supplying,fixing,wiring,earth electrode for grounding conduits,I.C.cutouts and other equipment's on the meter board using 40mm dia 2.90mm thick GI pipe 2.5m long buried in a pit.The pit should be filled with equal proportion of salt and charcoal 150 mm all-round the pipe to complete depth.The connection from the pipe to the conduit etc.,is to be established through GIwire of size asper lSI specification 7.3.3.of IS 732 using 12mm dia bolts,nuts,washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia.PWD Electrical SR-2023-24, ITEM NO:12.56,CH-12, PAGE NO-54No3615.33615.32.0FalseNoneNoneFalseNoneFalse7230.60
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17187844500000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17187844500000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17187844500000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17187844500000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17187844500000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneSatisfactory completed, at least one similar Building works of value not less than Rs. 49.95 Lakhs as prime contractor (In support of the above, work done certificate duly certified by an officer not below the rank of Executive Engineer should be uploaded)Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneSatisfactory Performance Certificate
NoneNoneNoneNoneExecuted in any one year the following minimum quantities of work 80% of the value (Earth work Excavation/Embankment - 497.49cum, Cement Concrete/RCC - 192.24cum, Size stone Masonry - 33.43 cum, Solid concrete blocks - 219.54 sqmt, TMT Steel 7.01 MT, Structural Steel work-21808 Kgs, Galvanised iron profile sheets/ GI sheets/ AC sheets- 1299 sqmt)Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid Electrical License for executing building electrificatio works and should have executed similar electrical works totallng Rs.1.65 Lakhs(not less than 50% of electrical works) n any one year.Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneTotal value of civil engineering works executed and payments received in the last five years (2019-20 to 2023-24)Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneQualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awardedCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Workforce
NoneNoneNoneNonePWD Registration Certificate issued by competent authority not below the rank of superintending engineer or chief engineer PWD class III and above.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNonePWD Registration Certificate (Class I/II/III/IV)
NoneNoneNoneNoneGST Registration issued by competent authority to be uploaded.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneGST Registration
NoneNoneNoneNoneAs Per Tender DocumentCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- As Per Tender Document
NoneNoneNoneNoneAchieved in at least two financial years in the previous 5years (2019-20 to 2023-24)minimum annual financial turnover of Rs.99.90 lakhs. (Turnover certificate issued by CA with valid UDIN No. to be furnished along with necessary documents.)Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNoneLiquid assets and /or availability of credit facilities of no less than Rs. 30.00 Lakhs issued by Nationalized/Scheduled bank in the prescribed format (estimated cash flow for 3 months of peak construction period)Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneLine of Credit
NoneNoneNoneNoneTenderer should furnish reports on the financial standing such as profit and loss statements and Auditor reports attested by Chartered Accountant for the last five yearsFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid license for executing water supply / sanitary engineering works and should have executed similar works totaling Rs.0 (not less than 50% of electrical works) n any one year. (Not Applicable)Otherswater works
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- workdone
NoneNoneNoneNoneOwning the following key and critical equipment for this work (Deleted as per circular no FD 263 cost 12/2022 dated 11.05.2022)Otherskey and critical equipment
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- key and critical equipment
NoneNoneNoneNoneShould furnish List of existing commitments and ongoing works in the prescribed format.OthersExisting commitments
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Existing commitments and ongoing works
NoneNoneNoneNoneTenderer should furnish the list of works for which tenders already submitted.OthersExisting commitments
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Existing commitments and ongoing works
NoneNoneNoneNoneTenderer should furnish Banker Details for reference.OthersBanker details
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Banker details
NoneNoneNoneNoneNot ApplicableOthersConstruction equipment
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Construction equipment
NoneNoneNoneNoneList of Financial Resources with Certificates attested by competent authority to be enclosedOthersFinancial resources
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Financial resources
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Annual Turnover CertificateTrueTechnical Bid
Class-3 and above PWD Registration CertificateTrueTechnical Bid
Satisfactory at least one similar Building works of value not less than Rs. 49.95 Lakhs as prime contractor support of the above, work done certificate has to be duly certified by an officer not below the rank of Executive EngineerTrueTechnical Bid
Line of CreditTrueTechnical Bid
ITR Filed CopyTrueTechnical Bid
GST RegistrationTrueTechnical Bid
Executed in one year the following minimum quantities of work signed by officer not below the rank of Executive EngineerTrueTechnical Bid
tenderWorkLocationList
tenderAddress
createdTs1718952050000
version0
createdDateNone
modifiedDateNone
blockNumberCity Municipal Council
streetNone
cityChannapatna
stateKarnataka
pin562160
tenderRecallDTONone