1719231901000 | 0 | None | None | Other Works | CONSTRUCTION OF GOVERMNENT URDU HIGHER PRIMARY THREE ROOM SCHOOL BUILDING TO AYUNUR VILLAGE IN AYUNUR GP AT SHIVAMOGHA TALUK SHIVAMOGHA DISTRICT | 3470870.5 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3338378 | 117207 | None | 1.12 | Earth work in surface excavation by mechanical means for lowering &leveling the ground for allworks other than foundation in all kinds ofsoils &upto depth not exceeding 300mm as per drawing and technicalspecifications, including setting out,shoring, strutting, barricading, cautionlights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing of for levelling the excavated earth or sorting & stacking the selected earth forreuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work.(PWD SR P-10, I No 1.12) (PWD SR 2021-22) Volume-1 | Cum | 68.25 | 68.25 | 75.0 | False | None | None | False | None | False | 5118.75 | 0 | 3338379 | 117207 | None | 1.15.1 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications,including setting out, shoring, strutting, barricading, caution lights,including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In ordinary/soft rock without blasting upto 1.5 m depth (P.No.8/I.No. 1.15.1 of PWD CM SR ) V-1
| Cum | 285.6 | 285.6 | 116.35 | False | None | None | False | None | False | 33229.56 | 0 | 3338380 | 117207 | None | 2.1.3 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm and down size graded crushed coarse aggregates (P.NO. A(67)/2.1.3/PWDSR/21-22). volume-1
| Cum | 5831.7 | 5831.7 | 31.32 | False | None | None | False | None | False | 182648.844 | 0 | 3338381 | 117207 | None | 2.4.3 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm and down size graded crushed coarse aggregates(P.No.17 /I.No. 2.4.3 of PWD CM SR) V-1
| Cum | 6480.35 | 6480.35 | 23.4 | False | None | None | False | None | False | 151640.19 | 0 | 3338382 | 117207 | None | 2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes finsishing concrete structure in line, all lead & lifts, cost of all materials,quality confirming to the requirements of relevant IS codes , labour,Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm and down size graded crushed coarse aggregates (P.No.17 /I.No. 2.5.2 of PWD CM SR) V-1
| Cum | 9742.95 | 9742.95 | 27.84 | False | None | None | False | None | False | 271243.728 | 0 | 3338383 | 117207 | None | 11.32 | Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) (P.No.84/I.No. 11.32 of PWD SR) V-2
| Kg | 96.6 | 96.6 | 7190.85 | False | None | None | False | None | False | 694636.11 | 0 | 3338384 | 117207 | None | 5.3 | Providing Coursed rubble masonry (second sort) with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) (1 cement : 6 coarse sand) (P.NO. 9/5.3/PWDSR/2021-22). volume-2
| Cum | 5457.9 | 5457.9 | 47.79 | False | None | None | False | None | False | 260833.041 | 0 | 3338385 | 117207 | None | 5.4 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)(P.NO. 9/5.4/PWDSR/21-22). Volume-2
| Cum | 5619.6 | 5619.6 | 17.86 | False | None | None | False | None | False | 100366.056 | 0 | 3338386 | 117207 | None | 1.8 | Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading,grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work.If the height of embankment construction is more than 1.50 m add5%perConstruction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading,grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work.If the height of embankment construction is more than 1.50 m add 5%per cumforevery1.50mheightorpartthereoff(Pno7ino1.8PWDCMSR)VOLUME-1 | Cum | 422.1 | 422.1 | 164.31 | False | None | None | False | None | False | 69355.251 | 0 | 3338387 | 117207 | None | 11.26.3 | Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works,including applying priming coat of approved steel primer. G.I. pipes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (P.No. 82 / I.No11.26.3)
| Kg | 154.35 | 154.35 | 424.0 | False | None | None | False | None | False | 65444.4 | 0 | 3338388 | 117207 | None | 6.7 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. (P.NO. 13/6.7/PWDSR/21-22). Volume - 2
| Cum | 7295.4 | 7295.4 | 43.54 | False | None | None | False | None | False | 317641.716 | 0 | 3338389 | 117207 | None | 11.5.1 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour,usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.(Page No. 75 / Item No. 11.5.1) V-2
| Cum | 3843.0 | 3843.0 | 7.56 | False | None | None | False | None | False | 29053.08 | 0 | 3338390 | 117207 | None | 11.15.1 | Providing and fixing M.S. Tubular frames for doors, windows,ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer: Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (Page No. 80 / Item No. 11.15.1 PWD SR ) V-2
| Cum | 120.75 | 120.75 | 680.4 | False | None | None | False | None | False | 82158.3 | 0 | 3338391 | 117207 | None | 8.1.1 | Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding,including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(P.NO. 41/8.1.1/PWDSR/21-22). Volume-2
| Sqm | 223.65 | 223.65 | 153.96 | False | None | None | False | None | False | 34433.154 | 0 | 3338392 | 117207 | None | 8.2..2 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge(P.NO. 41/8.2.2/PWDSR/21-22). Volume-2
| Sqm | 241.5 | 241.5 | 241.14 | False | None | None | False | None | False | 58235.31 | 0 | 3338393 | 117207 | None | 8.3.1 | Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. [P.No-41 ,I.No-8.3.1] (PWD SR 2021-22) Volume-2
| Sqm | 313.95 | 313.95 | 372.74 | False | None | None | False | None | False | 117021.723 | 0 | 3338394 | 117207 | None | 2.1.4 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 20 mm and down size graded crushed coarse aggregates (P.NO. A(67)/2.1.4/PWDSR/21-22). volume-1
| Cum | 6014.4 | 6014.4 | 7.05 | False | None | None | False | None | False | 42401.52 | 0 | 3338395 | 117207 | None | 9.24 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye,River Pink or equivalent. (P.No.63/I.No.9.24 of PWD SR) V-2
| Sqm | 3013.5 | 3013.5 | 163.04 | False | None | None | False | None | False | 491321.04 | 0 | 3338396 | 117207 | None | 8.25 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge(P.No. 45/8.25/PWDSR/21-22). volume-2
| Sqm | 110.25 | 110.25 | 395.1 | False | None | None | False | None | False | 43559.775 | 0 | 3338397 | 117207 | None | 8.32 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. [P.No-46 ,I.No-8.32] (PWD SR 2021-22) Volume-2
| Sqm | 117.6 | 117.6 | 378.45 | False | None | None | False | None | False | 44505.72 | 0 | 3338398 | 117207 | None | 8.4 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. [P.No-48 ,I.No-8.40] (PWD SR 2021-22) Volume-2
| Sqm | 94.5 | 94.5 | 53.46 | False | None | None | False | None | False | 5051.97 | 0 | 3338399 | 117207 | None | 1182 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 1mm gap for thermal expansion PVC pipe - OD 90mm and 6 Kg/sqcm [P.No- 34, SI.No-1182] (PWD SR 2021-22) Volume-V
| Mtr | 182.7 | 182.7 | 30.1 | False | None | None | False | None | False | 5499.27 | 0 | 3338400 | 117207 | None | 22-23 | 1.2 Concealed Conduit System Supplying heavy gauge PVC conduit pipe . mm dia.mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 19/20 mm dia 2 mm thick (P.NO. 1/electrical items/22-23).
| Mtr | 61.0 | 61.0 | 210.0 | False | None | None | False | None | False | 12810.0 | 0 | 3338401 | 117207 | None | 1.5 | Supplying and fixing PVC/metal conduit Deep junction box1 9/20 mm deep junction box (P.NO. 1/1.5/electrical items/22-23).
| Nos | 49.0 | 49.0 | 18.0 | False | None | None | False | None | False | 882.0 | 0 | 3338402 | 117207 | None | 45 | Earthing: Supplying and fixing and wiring earth electrode for grounding circuits IC cutouts and other equipments on the meter board in the pit.The pits should be filled up with equal proportion of salt and charcoal 150mm around the pipe to complete depth. The connection from the pipe to the conduits etc. is to established through GI wire of sizes as per clause 7.3.3 of IS 732 using 12mm bolts, nuts, washers and check nuts, the pipe shall have 16 through holes of 12mm dia(PWD SR 2021-22 Vol-5, P.No.164 I.No.45)
| Job | 3937.5 | 3937.5 | 1.0 | False | None | None | False | None | False | 3937.5 | 0 | 3338403 | 117207 | None | 6.3 | Supplying capacitor type ceiling fan complete with down ro blades, shackle, canopies etc, for operation on 230 V, 50 cyclesSingle phase AC supply conforming to ISS-374- 1979 and witdouble ball bearing system. (P.NO. 22/6.3/electrical items/22-23). 56" Sweep (1400 mm) Regular model
| Nos | 2170.0 | 2170.0 | 6.0 | False | None | None | False | None | False | 13020.0 | 0 | 3338404 | 117207 | None | 2.3.2 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.(Pg.No-3 I.No-2.3.2,2.3.3 PWD Elec SR)
| m | 26.0 | 26.0 | 570.0 | False | None | None | False | None | False | 14820.0 | 0 | 3338405 | 117207 | None | 2.3.3 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.(Pg.No-3 I.No-2.3.2,2.3.3 PWD Elec SR)
| m | 40.0 | 40.0 | 285.0 | False | None | None | False | None | False | 11400.0 | 0 | 3338406 | 117207 | None | 11.3 | Supplying of .feet -PVC Batten with integrated LED tube W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80.Power Input: 220-240V@ 50/60HZ & Powe Factor 0.9 along with ce approved. 2 years Waranty against anymanufacturing defect working under standard electrical condition. (P.no 34/11.3/electrical Supplying of .feet -PVC Batten with integrated LED tube . W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V@ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. (P.NO. 34/11.3/electrical items/22-23). LED light fitting 1 x 2' - 9/10 W
| Nos | 496.0 | 496.0 | 12.0 | False | None | None | False | None | False | 5952.0 | 0 | 3338407 | 117207 | None | 11.3 | Supplying and flush mounting teak wooden box without front plank, made of not less than 12 mm thick wood, after due groove cutting, finishing with necessary cement plastering complete (P.NO. 34/11.3/electrical items/22-23).12" x 12" x 3" (300 x 300 x 76 mm)
| Nos | 112.0 | 112.0 | 1.0 | False | None | None | False | None | False | 112.0 | 0 | 3338408 | 117207 | None | 3.4.1 | Supplying and flush mounting powder coated/galvnized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/CC wall (P- 5, INo.- 3.4.1,3.4.3,3.4.5) (ELE SR 2022-23)
| Each | 123.0 | 123.0 | 3.0 | False | None | None | False | None | False | 369.0 | 0 | 3338409 | 117207 | None | 3.4.3 | Supplying and flush mounting powder coated/galvnized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/CC wall (P- 5, INo.- 3.4.1,3.4.3,3.4.5) (ELE SR 2022-23)
| Each | 212.0 | 212.0 | 3.0 | False | None | None | False | None | False | 636.0 | 0 | 3338410 | 117207 | None | 3.4.5 | Supplying and flush mounting powder coated/galvnized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/CC wall (P- 5, INo.- 3.4.1,3.4.3,3.4.5) (ELE SR 2022-23)
| Each | 325.0 | 325.0 | 3.0 | False | None | None | False | None | False | 975.0 | 0 | 3338411 | 117207 | None | 3.5.1 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box (P- 5, INo.- 3.5.1,3.5.3,3.5.5) (ELE SR 2022-23)
| Each | 152.0 | 152.0 | 3.0 | False | None | None | False | None | False | 456.0 | 0 | 3338412 | 117207 | None | 3.5.3 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box (P- 5, INo.- 3.5.1,3.5.3,3.5.5) (ELE SR 2022-23)
| Each | 244.0 | 244.0 | 3.0 | False | None | None | False | None | False | 732.0 | 0 | 3338413 | 117207 | None | 3.5.5 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box (P- 5, INo.- 3.5.1,3.5.3,3.5.5) (ELE SR 2022-23)
| Each | 363.0 | 363.0 | 3.0 | False | None | None | False | None | False | 1089.0 | 0 | 3338414 | 117207 | None | 3.6.3 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.(PWD Electrical SR 2022-23 P.No.5 I.No.3.6.1, 3.6.2, 3.6.3,3.6.4,3.6.8 & 3.6.11)
| Nos | 88.0 | 88.0 | 24.0 | False | None | None | False | None | False | 2112.0 | 0 | 3338415 | 117207 | None | 3.6.8 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.(PWD Electrical SR 2022-23 P.No.5 I.No.3.6.1, 3.6.2, 3.6.3,3.6.4,3.6.8 & 3.6.11)
| Nos | 162.0 | 162.0 | 12.0 | False | None | None | False | None | False | 1944.0 | 0 | 3338416 | 117207 | None | 3.11 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.(PWD Electrical SR 2022-23 P.No.5 I.No.3.6.1, 3.6.2, 3.6.3,3.6.4,3.6.8 & 3.6.11)
| Nos | 281.0 | 281.0 | 3.0 | False | None | None | False | None | False | 843.0 | 0 | 3338417 | 117207 | None | 5.18.1 | Supplying and fixing regular MCB distribution boards on wall/wood board/flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCBs single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure (P- 13, INo.- 5.18.1) (ELE SR 2022-23)
| Each | 1104.0 | 1104.0 | 3.0 | False | None | None | False | None | False | 3312.0 | 0 | 3338418 | 117207 | None | 37.30 | Providing wall black boards in CM 1:3 with two coats of black paint including finishing etc., imcluding cost of materials, labour, HOM complete as per specifications.(P-268, INo-37.30) (PWD SR 2018-19)
| Each | 865.2 | 865.2 | 5.0 | False | None | None | False | None | False | 4326.0 | 0 | 3338419 | 117207 | None | 2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes finsishing concrete structure in line, all lead & lifts, cost of all materials,quality confirming to the requirements of relevant IS codes , labour,Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm and down size graded crushed coarse aggregates (P.No.17 /I.No. 2.5.2 of PWD CM SR) V-1
| Cum | 11042.01 | 11042.01 | 7.86 | False | None | None | False | None | False | 86790.1986 | 0 | 3338420 | 117207 | None | 2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes finsishing concrete structure in line, all lead & lifts, cost of all materials,quality confirming to the requirements of relevant IS codes , labour,Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm and down size graded crushed coarse aggregates (P.No.17 /I.No. 2.5.2 of PWD CM SR) V-1
| Cum | 9742.95 | 9742.95 | 8.31 | False | None | None | False | None | False | 80963.9145 | 0 | 3338421 | 117207 | None | 2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes finsishing concrete structure in line, all lead & lifts, cost of all materials,quality confirming to the requirements of relevant IS codes , labour,Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm and down size graded crushed coarse aggregates (P.No.17 /I.No. 2.5.2 of PWD CM SR) V-1
| Cum | 9418.19 | 9418.19 | 1.35 | False | None | None | False | None | False | 12714.5565 | 0 | 3338422 | 117207 | None | 2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes finsishing concrete structure in line, all lead & lifts, cost of all materials,quality confirming to the requirements of relevant IS codes , labour,Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm and down size graded crushed coarse aggregates (P.No.17 /I.No. 2.5.2 of PWD CM SR) V-1
| Cum | 10392.48 | 10392.48 | 10.13 | False | None | None | False | None | False | 105275.8224 | 0 |
|