createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1719215495918
version6
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyRESERVED
invitingStrategyTextReserved
taxTypeINCLUSIVE_TAX
tenderFee1420.00
emd56750.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose04-07-2024 16:00:00
tenderQueryClose03-07-2024 17:30:00
technicalBidOpen05-07-2024 16:30:00
publishedDate24-06-2024 16:43:54
publishedByPostPWD_EE_DIV_HSN
publishedByUserKPE15800 - K R HEMANTH
bidValidityPeriod90
noOfCalls2
preBidMeetingDateNone
preBidMeetingYnFalse
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnTrue
percentageRateTypeTextNone
contactPersonShwetha
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumber08172268437
mobileNumberNone
tenderSupplierListNone
tenderSchedule
createdTs1719215495921
version20
createdDateNone
modifiedDateNone
tenderNumberPWD/2023-24/BD/WORK_INDENT5556/CALL-2
titleConstruction of First Floor to CH-1 and CH-2 in the premises of Arasikere IB in Arasikere tq.
descriptionConstruction of First Floor to CH-1 and CH-2 in the premises of Arasikere IB in Arasikere tq.
categoryWORKS
categoryTextWorks
ecv5674869.30
deptNamePublic Works Department
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnTrue
location1771
locationNamePWD Division Office Hassan
provisionalAmount7500000.0
groupOverheadTotalNone
fileNumberPWD/AEE/ARS/BUILDING/24
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17192154960000NoneNoneBuildingsConstruction of First Floor to CH-1 and CH-2 in the premises of Arasikere IB in Arasikere tq.(Water supply)615685.88
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3335208117038Volume-2-For Buildings Chapter-14-Sanitary Installations14.40.2600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g. ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.each380.0380.06.0FalseNoneNoneFalseNoneFalse2280.00
3335210117038Volume-2-For Buildings Chapter-14-Sanitary Installations14.33Providing and fixing 600x120x5 mm glass shelf with edges round off, supported on anodised aluminium angle frame with C.P. brass brackets and guard rail complete fixed with 40 mm long screws, rawl plugs etc., complete. ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.each708.0708.020.0FalseNoneNoneFalseNoneFalse14160.00
3335209117038None13.32.1 (Corrigendum 13.32)Providing and fixing Chorinated Poly Vinyl Chloride (CPVC) pipes having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr spacing. This includes jointing of pipes and fi with one step CPVC solvent cement & the cost of cutting chases & making good the same including testing of joints complete. (Concealed work including cutting chases and making good walls) 15mm nominal OD Pipe13.32.1 (Corrigendum 13.32) ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Rmtr306.0306.09.0FalseNoneNoneFalseNoneFalse2754.00
3335211117038None13.32.2 (Corrigendum 13.32)Providing and fixing Chorinated Poly Vinyl Chloride (CPVC) pipes having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr spacing. This includes jointing of pipes and fi with one step CPVC solvent cement & the cost of cutting chases & making good the same including testing of joints complete. (Concealed work including cutting chases and making good walls) 20mm nominal OD Pipe13.32.2 (Corrigendum 13.32) ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Rmtr373.0373.08.0FalseNoneNoneFalseNoneFalse2984.00
3335212117038None13.32.3 (Corrigendum 13.32)Providing and fixing Chorinated Poly Vinyl Chloride (CPVC) pipes having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr spacing. This includes jointing of pipes and fi with one step CPVC solvent cement & the cost of cutting chases & making good the same including testing of joints complete. (Concealed work including cutting chases and making good walls) 25mm nominal OD Pipe13.32.3 (Corrigendum 13.32) ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Rmtr476.0476.08.0FalseNoneNoneFalseNoneFalse3808.00
3335213117038None13.31.6 (Corrigendum 13.31)Providing and fixing Chorinated Poly Vinyl Chloride (CPVC) pipes having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete. (internal work exposed on wall) 50mm nominal OD Pipe13.31.6 (Corrigendum 13.31) ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Rmtr767.0767.030.0FalseNoneNoneFalseNoneFalse23010.00
3335214117038None13.31.4 (Corrigendum 13.31)Providing and fixing Chorinated Poly Vinyl Chloride (CPVC) pipes having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete. (internal work exposed on wall) 32mm nominal OD Pipe13.31.4 (Corrigendum 13.31) ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Rmtr393.0393.0100.0FalseNoneNoneFalseNoneFalse39300.00
3335215117038None13.12Providing and fixing C.P. brass bib cock of approved quality conforming 117/13.12 Vol-2 ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Nos432.0432.020.0FalseNoneNoneFalseNoneFalse8640.00
3335216117038None13.16 Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931r 117/13.16 Vol-3 ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Nos.493.0493.020.0FalseNoneNoneFalseNoneFalse9860.00
3335217117038None13.9.2Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 150mm Diameter 116/13.9.2 Vol-2 ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Nos.220.0220.020.0FalseNoneNoneFalseNoneFalse4400.00
3335218117038None13.4.1Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 25 mm nominal bore115/13.4.1 Vol-2 ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Nos.528.0528.02.0FalseNoneNoneFalseNoneFalse1056.00
3335219117038None13.4.2Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 32 mm nominal bore Nos.115/13.4.2 Vol-2 ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Nos.577.0577.02.0FalseNoneNoneFalseNoneFalse1154.00
3335220117038None13.4.4Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 50 mm nominal bore Nos.115/13.4.4 Vol-2 ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Nos834.0834.02.0FalseNoneNoneFalseNoneFalse1668.00
3335221117038None14.32.2Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :Rectangular shape 453x357 mm128/Vol-2 (14.32.2) ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Nos.869.0869.08.0FalseNoneNoneFalseNoneFalse6952.00
3335222117038None14.10.1.1Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : 510x1040 mm bowl depth 250 mm126/Vol-2 (14.10.1.1) ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Nos4970.04970.08.0FalseNoneNoneFalseNoneFalse39760.00
3335223117038None1.6 (K010F) BWSSB SRSupplying, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc. Note: Upto 110mm dia Coil shall be used. For Grade PE80 PN6.0 : HDPE Grade PE80 PN6.0,140mm dia121/1.6 (K010F) BWSSB SR ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Rmtr716.9716.950.0FalseNoneNoneFalseNoneFalse35845.00
3335224117038None1.4 (K010D) BWSSB SRSupplying, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc. Note: Upto 110mm dia Coil shall be used. For Grade PE80 PN6.0 : HDPE Grade PE80-PN6.0,110mm dia121/1.4 (K010D) BWSSB SR ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Rmtr466.32466.32100.0FalseNoneNoneFalseNoneFalse46632.00
3335225117038None1.3 (K010C)Supplying, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with lectrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc. Note: Upto 110mm dia Coil shall be used. For Grade PE80 PN6.0 : HDPE Grade PE80-PN6.0, 90mm dia121/1.3 (K010C) BWSSB SR ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Rmtr318.92318.9214.0FalseNoneNoneFalseNoneFalse4464.880
3335226117038None14.1.2Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: Stainless Steel AISI-304(18/8) Orissa pattern W.C. pan of size 585x480 mm with flush pipe and integrated type foot rests123/Vol-2 (14.1.2) ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Nos8169.08169.02.0FalseNoneNoneFalseNoneFalse16338.00
3335227117038None14.3.1Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid 123/Vol-2 (14.3.1) ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Nos5005.05005.04.0FalseNoneNoneFalseNoneFalse20020.00
3335228117038None14.7.8Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Surgeon type wash basin of size 660x460 mm with a pair of 15 mm C.P. brass pillar taps with elbow including oper- ated levers125/Vol-2 (14.7.8) ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Each3386.03386.010.0FalseNoneNoneFalseNoneFalse33860.00
3335229117038NoneWS & UGD (T130C) BWSSB SRConstructing brick masonry chamber of internal dimension 450x450mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover187/WS & UGD (T130C) BWSSB SR ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Nos3864.03864.02.0FalseNoneNoneFalseNoneFalse7728.00
3335230117038NoneUGD (T300I) BWSSB SRProviding and constructing “WIRE CUT BRICK MACHINEHOLE CHAMBERS” using Portland/Pozzolana cement, conical in shape at top, with CC 1:3:6 foundation using 40mm and down size graded metal of approved quality and with an offset of 0.15M alround the chamber. Construct Brick masonry in CM 1:4, 340 mm thick, with wirecut bricks of approved quality, plaster inside and out side with CM 1:3, 12mm thick, except for the conical surface outside where the plaster thickness shall be 20mm. Slope inside to be 1:6 in the concrete towards central drain and finished smooth. Fixing of pipes in CC 1:2:4 with graded metal of 20mm 13 T300 and down size. Supplying and fixing SFRC Machinehole frame and cover (Heavy Duty) conforming to IS:12592 with latest amendment, in CC 1:2:4. Supplying and fixing footsteps made of 12mm dia. steel bars (Fe-500) with 3mm thick plastic encapsulation (IS-10910). The footsteps shall be fixed 30cms apart and on CC block embeded to masonry wall. The whole works include watering, curing, barricading, danger lighting, pouring tar over MH frame and cover, cost of tar, shoring, strutting, de- watering, engraving Machinehole number with flow direction on the inner conical surface etc. as per the drawing etc. as per technical specifications and for the following diameters and depth etc. for 1.2mm diaCirc. B M.H: Constructing Brick Masonry Circular Machinehole 1.2 m internal dia. , 1.8M depth & SFRC cover & frame188/WS & UGD (T300I) BWSSB SR ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Nos43385.043385.04.0FalseNoneNoneFalseNoneFalse173540.00
3335231117038NoneCorringendun 13.34Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.in Corringendun 13.34 ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Ltr8.08.010000.0FalseNoneNoneFalseNoneFalse80000.00
3335232117038None13.22.1.2 Providing and fixing PTMT grating of approved quality and colour. Circular type 125 mm nominal dia118/13.22.1.2 Vol-2 ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Nos.99.099.010.0FalseNoneNoneFalseNoneFalse990.00
3335233117038None14.22BProviding and fixing CP Brass 15 mm nominal dia Single lever telephonic wall mixer of quality & make as approved by Engineer in charge.127/14.22B Vol-2 ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Nos5747.05747.06.0FalseNoneNoneFalseNoneFalse34482.00
17192154960001NoneNoneBuildingsConstruction of First Floor to CH-1 and CH-2 in the premises of Arasikere IB in Arasikere tq.(Civil Work)4166387.42
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3335234117039Volume -1-Common SR- Chapter - I- Earth Work1.3Earth work in surface excavation by manual means for lowering & levelling the ground by chiselling and wedging in Hard rock for all works other than foundation & depth not exceeding 100 mm as per drawing and technical specifications, including setting out, barricading, caution lights, dressing of excavated surfaces, disposing off the excavated spalls/stuff & stacking the selected spall/ stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work. ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Sqm136.0136.060.0FalseNoneNoneFalseNoneFalse8160.00
3335237117039Volume-2-For Buildings Chapter-4-Anti-Termite Treatment4.1Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/Sqm including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications. ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Sqm95.095.066.27FalseNoneNoneFalseNoneFalse6295.650
3335238117039Volume -1-Common SR- Chapter - I- Earth Work1.8Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Cum402.0402.015.44FalseNoneNoneFalseNoneFalse6206.880
3335240117039Volume -1-Common SR- Chapter - I- Earth Work1.9Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Cum204.0204.075.7FalseNoneNoneFalseNoneFalse15442.80
3335243117039Volume-2-For Buildings Chapter-12-Wood & PVC Works12.13.1Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Cum61603.061603.00.07FalseNoneNoneFalseNoneFalse4312.210
3335244117039Volume-2-For Buildings Chapter-12-Wood & PVC Works12.84PProviding & fixing of 2-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6 PHR with TPE (Thermo Plastic Elastomer) and lead free, gaskets -grey color having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 44mm width x 40mmheight with reinforcement of 1mm thickness and Sash with overall size of 27mm X 53mm with UPVC honeycomb structure inside in lieu of GI reinforcement. Coextruded Glazing bead for fixing of glass shall be of size 9.5mm x 21.5mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with Crescent Locks. Wall thickness of frame & sash shall be of 2 mm.Maximum possible size – 1219mm x 1219mm. (The cost is inclusive of all fixtures and separate charges for minor T&Ps shall not be made) ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Sqm4114.04114.06.66FalseNoneNoneFalseNoneFalse27399.240
3335247117039Volume-2-For Buildings Chapter-8-Finishing8.39Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Sqm95.095.0704.53FalseNoneNoneFalseNoneFalse66930.350
3335248117039Volume-2-For Buildings Chapter-8-Finishing8.33.3Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90 ltr/10 Sqm over an under coat of primer applied @ 0.80 ltr/10 Sqm of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Sqm106.0106.021.6FalseNoneNoneFalseNoneFalse2289.60
3335250117039Volume-2-For Buildings Chapter-8-Finishing8.77Melamine polishing on wood work (one coat) including preparing the surface after thoroughly cleaning the surface to remove all dirt, dust and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Sqm88.088.02.31FalseNoneNoneFalseNoneFalse203.280
3335253117039Volume-2-For Buildings Chapter-15-Water Proofing15.1Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per Sqm to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per Sqm and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge. ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Sqm745.0745.0167.14FalseNoneNoneFalseNoneFalse124519.30
3335254117039Volume-2-For Buildings Chapter-12-Wood & PVC Works12.58Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Nos.109.0109.010.0FalseNoneNoneFalseNoneFalse1090.00
3335256117039Volume-2-For Buildings Chapter-12-Wood & PVC Works12.64Providing and fixing PTMT door catcher of length 72 mm and dia. of 42 mm with suitable washers weighing not less than 33 gms ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Nos.47.047.010.0FalseNoneNoneFalseNoneFalse470.00
3335235117039None19.7.1Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge.(P.No. 163/I.No. 19.7.1. VOL-II) ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Cum369.0369.05.68FalseNoneNoneFalseNoneFalse2095.920
3335236117039None1.14.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, 1.14 including dressing of excavated surfaces, disposing off or levelling the   excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Cum73.073.097.2FalseNoneNoneFalseNoneFalse7095.60
3335239117039None2.1.2Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates 15/2.1.2 Vol-1 ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Cum5206.05206.09.94FalseNoneNoneFalseNoneFalse51747.640
3335241117039None2.4.2Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates17/2.4.2 Vol-1 ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Cum5968.05968.011.56FalseNoneNoneFalseNoneFalse68990.080
3335242117039NonePage 115 Vol-1Providing and removing form work /Centering For Footing work ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Cum477.44477.4411.56FalseNoneNoneFalseNoneFalse5519.20640
3335245117039None2.5.1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates17/2.5.1 Vol-1 ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Cum6182.06182.016.93FalseNoneNoneFalseNoneFalse104661.260
3335246117039NonePage 115 Vol-1Providing and removing form work /Centering For Plinth Beam ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Cum3091.03091.08.6FalseNoneNoneFalseNoneFalse26582.60
3335249117039NonePage 115 Vol-1Providing and removing form work /Centering For Staircase ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Cum3091.03091.03.2FalseNoneNoneFalseNoneFalse9891.20
3335251117039NonePage 115 Vol-1Providing and removing form work /Centering For Roof Slab ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Cum3091.03091.02.58FalseNoneNoneFalseNoneFalse7974.780
3335252117039NonePage 115 Vol-1Providing and removing form work /Centering For Chejja ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Cum2781.92781.90.32FalseNoneNoneFalseNoneFalse890.2080
3335255117039NonePage 115 Vol-1Providing and removing form work /Centering For Lintel and Roof Beam Ground Floor ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Cum3709.23709.22.2FalseNoneNoneFalseNoneFalse8160.240
3335257117039None2.5.1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates17/2.5.1 Vol-1 ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Cum6243.826243.8245.06FalseNoneNoneFalseNoneFalse281346.52920
3335258117039NonePage 115 Vol-1Providing and removing form work /Centering For Staircase ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Cum3121.913121.913.2FalseNoneNoneFalseNoneFalse9990.1120
3335259117039NonePage 115 Vol-1Providing and removing form work /Centering For Lintel and Roof Beam ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Cum3746.293746.2913.44FalseNoneNoneFalseNoneFalse50350.13760
3335260117039NonePage 155 Vol-1Providing and removing form work /Centering For Roof Slab FF ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Cum3121.913121.9120.29FalseNoneNoneFalseNoneFalse63343.55390
3335261117039NonePage 115 Vol-1Providing and removing form work /Centering For Chejja ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Cum2809.722809.721.34FalseNoneNoneFalseNoneFalse3765.02480
3335262117039None2.5.1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates17/2.5.1 Vol-1 TF ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Cum6306.266306.263.89FalseNoneNoneFalseNoneFalse24531.35140
3335263117039NonePage 115 Vol-1Providing and removing form work /Centering For Roof Slab TF ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Cum3153.133153.132.81FalseNoneNoneFalseNoneFalse8860.29530
3335264117039None2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates 17/2.5.2 Vol-1 ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Cum6186.06186.08.48FalseNoneNoneFalseNoneFalse52457.280
3335265117039None2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates 17/2.5.2 Vol-1 FF ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Cum6247.866247.864.35FalseNoneNoneFalseNoneFalse27178.1910
3335266117039None2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates 17/2.5.2 Vol-1 TF ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Cum6310.336310.332.32FalseNoneNoneFalseNoneFalse14639.96560
3335267117039NonePage 115 Vol-1Providing and removing form work /Centering For Columns ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Cum4330.24330.28.48FalseNoneNoneFalseNoneFalse36720.0960
3335268117039NonePage 115 Vol-1Providing and removing form work /Centering For Columns FF ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Cum4373.54373.54.35FalseNoneNoneFalseNoneFalse19024.7250
3335269117039NonePage 115 Vol-1Providing and removing form work /Centering For Columns TF ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Cum4417.244417.242.32FalseNoneNoneFalseNoneFalse10247.99680
3335270117039None6.2Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work13/6.2 Vol-2 ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Cum6696.06696.017.23FalseNoneNoneFalseNoneFalse115372.080
3335271117039None6.2Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work13/6.2 Vol-2 ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Cum6762.966762.9655.82FalseNoneNoneFalseNoneFalse377508.42720
3335272117039None6.2Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work13/6.2 Vol-2 ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Cum6830.586830.5821.11FalseNoneNoneFalseNoneFalse144193.54380
3335273117039None12.13.2Providing Red Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications.100/12.13.2 Vol-2 ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Cum62219.0362219.030.57FalseNoneNoneFalseNoneFalse35464.84710
3335274117039None12.57.1Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 30 mm thick Both side teak 106/12.57.1 Vol-2 ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Sqm3799.03799.02.31FalseNoneNoneFalseNoneFalse8775.690
3335275117039None12.57.1Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 30 mm thick Both side teak 106/12.57.1 Vol-2 ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Sqm3836.993836.9920.58FalseNoneNoneFalseNoneFalse78965.25420
3335276117039None12.84Providing & fixing of 2-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6 PHR with TPE (Thermo Plastic Elastomer) and lead free, gaskets -grey color having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 44mm width x 40mmheight with reinforcement of 1mm thickness and Sash with overall size of 27mm X 53mm with UPVC honeycomb structure inside in lieu of GI reinforcement. Coextruded Glazing bead for fixing of glass shall be of size 9.5mm x 21.5mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with Crescent Locks. Wall thickness of frame & sash shall be of 2 mm.Maximum possible size 1219mm x 1219mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)110/12.84 Vol-2 FF ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Sqm4155.144155.1419.98FalseNoneNoneFalseNoneFalse83019.69720
3335277117039None12.84Providing & fixing of 2-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6 PHR with TPE (Thermo Plastic Elastomer) and lead free, gaskets -grey color having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 44mm width x 40mmheight with reinforcement of 1mm thickness and Sash with overall size of 27mm X 53mm with UPVC honeycomb structure inside in lieu of GI reinforcement. Coextruded Glazing bead for fixing of glass shall be of size 9.5mm x 21.5mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with Crescent Locks. Wall thickness of frame & sash shall be of 2 mm.Maximum possible size 1219mm x 1219mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)110/12.84 Vol-2 TF ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Sqm4196.694196.692.22FalseNoneNoneFalseNoneFalse9316.65180
3335278117039None12.85Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)110/12.85 Vol-2 ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Sqm4918.74918.71.62FalseNoneNoneFalseNoneFalse7968.2940
3335279117039None11.5.1Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.75/11.5.1 Vol-2 ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Sqm3733.573733.571.89FalseNoneNoneFalseNoneFalse7056.44730
3335280117039None9.24Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent.63/9.24 Vol-2 ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Sqm2870.02870.034.51FalseNoneNoneFalseNoneFalse99043.70
3335281117039None9.24Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent.63/9.24 Vol-2 FF ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Sqm2898.72898.741.92FalseNoneNoneFalseNoneFalse121513.5040
3335282117039None9.17.3Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 800x800 mm61/9.17.3 Vol-2 ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Sqm1403.01403.018.5FalseNoneNoneFalseNoneFalse25955.50
3335283117039None9.17.3Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 800x800 mm61/9.17.3 Vol-2 FF ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Sqm1417.031417.0381.38FalseNoneNoneFalseNoneFalse115317.90140
3335284117039None9.11Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete.71/9.11 Vol-2 FF ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Sqm762.0762.017.46FalseNoneNoneFalseNoneFalse13304.520
3335285117039None9.11Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete.71/9.11 Vol-2 FF ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Sqm769.62769.6217.46FalseNoneNoneFalseNoneFalse13437.56520
3335286117039None9.39Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications.65/9.39 Vol-2 ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Sqm1037.01037.057.29FalseNoneNoneFalseNoneFalse59409.730
3335287117039None9.39Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications.65/9.39 Vol-2 FF ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Sqm1047.371047.3759.39FalseNoneNoneFalseNoneFalse62203.30430
3335288117039None8.2.2Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.41/8.2.2 Vol-2 ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Sqm230.0230.062.5FalseNoneNoneFalseNoneFalse14375.00
3335289117039None8.2.2Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.41/8.2.2 Vol-2 FF ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Sqm232.3232.3473.81FalseNoneNoneFalseNoneFalse110066.0630
3335290117039None8.2.2Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.41/8.2.2 Vol-2 TF ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Sqm234.62234.6251.15FalseNoneNoneFalseNoneFalse12000.8130
3335291117039None7.18Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications23/7.18 Vol-2. ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Cum2017.02017.04.36FalseNoneNoneFalseNoneFalse8794.120
3335292117039None11.32Providing Thermo-Mechanically Treated bars of grade Fe-550D Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately)84/11.32 Vol-2 (Issue Rate) ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Kg92.092.04064.03FalseNoneNoneFalseNoneFalse373890.760
3335293117039None11.32Providing Thermo-Mechanically Treated bars of grade Fe-550D Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately)84/11.32 Vol-2 (Issue Rate) ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Kg92.9292.924688.22FalseNoneNoneFalseNoneFalse435629.40240
3335294117039None11.32Providing Thermo-Mechanically Treated bars of grade Fe-550D Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately)84/11.32 Vol-2 (Issue Rate) TF ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Kg93.8593.85589.8FalseNoneNoneFalseNoneFalse55352.730
3335295117039None8.8Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.42/8.8 Vol-2 ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Sqm307.0307.0102.54FalseNoneNoneFalseNoneFalse31479.780
3335296117039None8.8Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.42/8.8 Vol-2 FF ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Sqm310.07310.07166.38FalseNoneNoneFalseNoneFalse51589.44660
3335297117039None8.8Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.42/8.8 Vol-2 TF ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Sqm313.17313.17148.32FalseNoneNoneFalseNoneFalse46449.37440
3335298117039None8.51Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.50/8.51 Vol-2 ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Sqm83.083.096.74FalseNoneNoneFalseNoneFalse8029.420
3335299117039None8.51Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.50/8.51 Vol-2 FF ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Sqm83.8383.83607.79FalseNoneNoneFalseNoneFalse50951.03570
3335300117039None8.51Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.50/8.51 Vol-2 TF ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Sqm84.6784.6769.84FalseNoneNoneFalseNoneFalse5913.35280
3335301117039None8.39Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.48/8.39 Vol-2 FF ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Sqm95.9595.95607.79FalseNoneNoneFalseNoneFalse58317.45050
3335302117039None8.39Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.48/8.39 Vol-2 TF ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Sqm96.9196.9169.84FalseNoneNoneFalseNoneFalse6768.19440
3335303117039None8.29Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.45/8.29 Vol-2 ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Sqm208.0208.0269.53FalseNoneNoneFalseNoneFalse56062.240
3335304117039None8.29Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.45/8.29 Vol-2 FF ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Sqm210.08210.08166.4FalseNoneNoneFalseNoneFalse34957.3120
3335305117039None8.29Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.45/8.29 Vol-2 TF ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Sqm212.18212.18148.33FalseNoneNoneFalseNoneFalse31472.65940
3335306117039None8.77Melamine polishing on wood work (one coat) including preparing the surface after thoroughly cleaning the surface to remove all dirt, dust and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.54/8.77 Vol-2 FF ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Sqm88.8888.8820.58FalseNoneNoneFalseNoneFalse1829.15040
3335307117039None8.33.3Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @ 0.80 ltr/10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.47/8.33.3 Vol-2 FF ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Sqm107.06107.0621.6FalseNoneNoneFalseNoneFalse2312.4960
3335308117039None11.34BProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc.85/11.34B Vol-2 (Issue Rate) ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Kg157.0157.0139.86FalseNoneNoneFalseNoneFalse21958.020
3335309117039None11.34BProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc.85/11.34B Vol-2 (Issue Rate) FF ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Kg158.57158.57453.6FalseNoneNoneFalseNoneFalse71927.3520
3335310117039None12.51Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications.105/12.51 Vol-2 FF ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.No1495.811495.819.0FalseNoneNoneFalseNoneFalse13462.290
3335311117039None11.28Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners,stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts,bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.83/11.28 Vol-2 ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Kg500.0500.089.6FalseNoneNoneFalseNoneFalse44800.00
3335312117039None11.28Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners,stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts,bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.83/11.28 Vol-2 FF ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Kg505.0505.089.6FalseNoneNoneFalseNoneFalse45248.00
3335313117039None12.76.1Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete : 250x10mm109/12.76.1 Vol 2 ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Nos337.0337.030.0FalseNoneNoneFalseNoneFalse10110.00
3335314117039None12.76.3Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete : 150x10mm109/12.76.3 Vol 2 ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Nos.211.0211.020.0FalseNoneNoneFalseNoneFalse4220.00
3335315117039None12.75.1Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : 125x85x5.5 mm (heavy type)108/12.75.1 Vol 2 ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Nos201.0201.040.0FalseNoneNoneFalseNoneFalse8040.00
3335316117039None12.75.3Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : 100x85x5.5 mm (heavy type)109/12.75.3 Vol 2 ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Nos153.0153.030.0FalseNoneNoneFalseNoneFalse4590.00
3335317117039None12.79.1Providing and fixing bright finished brass handles with screws etc. complete: Brass handles 125 mm with plate 175x32 mm109/12.79.1 Vol 2 ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Nos184.0184.020.0FalseNoneNoneFalseNoneFalse3680.00
3335318117039None12.79.2Providing and fixing bright finished brass handles with screws etc. complete: Brass handles 100 mm with plate 150x32 mm109/12.79.2 Vol 2 ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Nos171.0171.020.0FalseNoneNoneFalseNoneFalse3420.00
3335319117039None12.51Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications.105/12.51 Vol-2 ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.No1481.01481.01.0FalseNoneNoneFalseNoneFalse1481.00
17192154960000NoneNoneBuildingsConstruction of First Floor to CH-1 and CH-2 in the premises of Arasikere IB in Arasikere tq.(Electrical work)892796.0
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3335320117040None1.1.2Open Conduit System : Supplying heavy gauge PVC conduit pipe dia mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc., and fixing using inverted wood plugs in case of RCC ceiling and RCC wall / stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF Screws. Chapter-1.I.no.1.1.2 a) 25 mm dia 2mm thick ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Mtr80.080.035.0FalseNoneNoneFalseNoneFalse2800.00
3335321117040None1.2.2Concealed Conduit System : Supplying heavy gauge PVC conduit pipe mm dia mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary Chapter-1.I.no.1.2.2 a) 25 mm dia 2mm thick ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Mtr70.070.0220.0FalseNoneNoneFalseNoneFalse15400.00
3335322117040None1.3.2Supplying heavy gauge PVC Conduit Pipe ….dia mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. Chapter-1.I.no.1.3.2 a) 25 mm dia 2mm thick ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Mtr80.080.0140.0FalseNoneNoneFalseNoneFalse11200.00
3335323117040None1.5.2Supplying and fixing PVC/metal conduit Deep junction box Chapter-1.I.no.1.5.2 a) 25mm deep junction box ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Each51.051.050.0FalseNoneNoneFalseNoneFalse2550.00
3335324117040None1.12Supplyin and Fixing Metal Fan Box with Round Hook. Chapter-1.I.no.1.12 ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.No163.0163.04.0FalseNoneNoneFalseNoneFalse652.00
3335325117040None2.2.1Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Chapter-2.I.no.2.2.1 a) Short point up to 3Mtr from tapping point to out let via switch ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Each251.0251.07.0FalseNoneNoneFalseNoneFalse1757.00
3335326117040None2.2.2Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Chapter-2.I.no.2.2.2, a) Medium point above 3mtr up to 6Mtr from tapping point to out let via switch ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Each361.0361.050.0FalseNoneNoneFalseNoneFalse18050.00
3335327117040None2.3.2Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Chapter-2.I.no.2.3.3 b)Long point above 6Mtr up to 10Mtr from tapping point to out let via switch ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Each542.0542.030.0FalseNoneNoneFalseNoneFalse16260.00
3335328117040None2.3.1Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. Chapter-2, I.no.2.3.1a) 1 sqmm ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Mtr26.026.0250.0FalseNoneNoneFalseNoneFalse6500.00
3335329117040None2.3.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. Chapter-2, I.no. 2.3.3, b) 2.5 sqm ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Mtr40.040.0550.0FalseNoneNoneFalseNoneFalse22000.00
3335330117040None2.3.4Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. Chapter-2, I.no.2.3.4, c) 4 sqmm ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Mtr59.059.0250.0FalseNoneNoneFalseNoneFalse14750.00
3335331117040None2.3.5Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. Chapter-2, I.no. 2.3.5 d) 6sqmm ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Mtr87.087.080.0FalseNoneNoneFalseNoneFalse6960.00
3335332117040None2.6.2Supplying and drawing 3 core flat PVC sheathed submersible pump cable manufactured with electrolytic grade copper with flexible copper with low resistance conductor confirming to IS:8130-1984 and virgin grade PVC insulation and powder coating extruded PVC sheathed suitable for working voltage upto 1100Volts as per IS-694:1990.3C X 2.5Sq.mm Chapter-2. I.no.2.6.2 ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Mtr113.0113.050.0FalseNoneNoneFalseNoneFalse5650.00
3335333117040None3.4.1Supplying and flush mounting powder coated / galvanised metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall Chapter-3. I.no.3.4.1,a) 1-3 Way ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Each123.0123.012.0FalseNoneNoneFalseNoneFalse1476.00
3335334117040None3.4.2Supplying and flush mounting powder coated / galvanised metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall Chapter-3. I.no.3.4.2, b) 4-5 Way ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Each138.0138.02.0FalseNoneNoneFalseNoneFalse276.00
3335335117040None3.4.4Supplying and flush mounting powder coated / galvanised metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall Chapter-3. I.no. 3.4.4, d) 8 Way ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Each250.0250.04.0FalseNoneNoneFalseNoneFalse1000.00
3335336117040None3.4.5Supplying and flush mounting powder coated / galvanised metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall Chapter-3. I.no.3.4.5, e)10-12 Way ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Each325.0325.010.0FalseNoneNoneFalseNoneFalse3250.00
3335337117040None3.5.1Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.Chapter-3,I.no.3.5.1a) 1 to 3 Module ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Each152.0152.024.0FalseNoneNoneFalseNoneFalse3648.00
3335338117040None3.5.2Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.Chapter-3,I.no.3.5.2,b) 4 Module ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Each175.0175.04.0FalseNoneNoneFalseNoneFalse700.00
3335339117040None3.5.5Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.Chapter-3,I.no.3.5.5, e) 10-12 Module ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Each363.0363.020.0FalseNoneNoneFalseNoneFalse7260.00
3335340117040None3.6.1Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Chapter-3, I.No.3.6.1a) 6Amps one way Switch ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Each88.088.0150.0FalseNoneNoneFalseNoneFalse13200.00
3335341117040None3.6.2Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.Chapter-3, I.No. 3.6.2,b) 6Amps Two way Switch ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Each152.0152.020.0FalseNoneNoneFalseNoneFalse3040.00
3335342117040None3.6.3Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.Chapter-3, I.No.3.6.3 c) 6Amps 3 way socket ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Each162.0162.070.0FalseNoneNoneFalseNoneFalse11340.00
3335343117040None3.6.4Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.Chapter-3, I.No.3.6.4,d) Stepped Fan Regulator. ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Each313.0313.08.0FalseNoneNoneFalseNoneFalse2504.00
3335344117040None3.6.10Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Chapter-3, I.No.3.6.10f) 32Amps DP switch ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Each375.0375.015.0FalseNoneNoneFalseNoneFalse5625.00
3335345117040None3.6.8Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Chapter-3, I.No.3.6.8 ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Each249.0249.08.0FalseNoneNoneFalseNoneFalse1992.00
3335346117040None3.6.12Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.Chapter-3, I.No.3.6.12h) TV/Telephone socket ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Each147.0147.08.0FalseNoneNoneFalseNoneFalse1176.00
3335347117040None3.14.6Supplying and fixing/replacing of 6/16/32Amps electrical accessories on existing switch board.Chapter-3, I.No.3.14.6 a) 6Amps lamp holder ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Each63.063.025.0FalseNoneNoneFalseNoneFalse1575.00
3335348117040None5.14.7Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. FOUR Pole 100 A 25 kA Chapter-5, I.no. 5.14.7 ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Each8265.08265.01.0FalseNoneNoneFalseNoneFalse8265.00
3335349117040None5.17.4Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.Chapter-5.I.no.5.17.4 a) 6 - 32 Amps DP ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Each1103.01103.010.0FalseNoneNoneFalseNoneFalse11030.00
3335350117040None5.17.4Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.Chapter-5.I.no.5.17.4 b) 6 - 32 Amps TPN ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Each1777.01777.04.0FalseNoneNoneFalseNoneFalse7108.00
3335351117040None5.18.9Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG MS enclosure. Double Door b) 12Way SP &N Chapter-13, I.no. 5.18.9 ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Each2067.02067.04.0FalseNoneNoneFalseNoneFalse8268.00
3335352117040None5.21Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker (ELMCB) 240/450V up to 300mA sensitivity on existing wood/panel board.16-25 Amps 2 pole Chapter-14 I.no. 5.21 ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Each8316.08316.01.0FalseNoneNoneFalseNoneFalse8316.00
3335353117040None5.33Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, kVA, kWH, kVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy Chapter-5, I.no. 5.33 ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Each8370.08370.01.0FalseNoneNoneFalseNoneFalse8370.00
3335354117040None5.38Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz 12/24V D.C Chapter-5, I.no. 5.38 ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Each464.0464.03.0FalseNoneNoneFalseNoneFalse1392.00
3335355117040None5.42.2Fabricating supplying and mounting MS box made out … SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete.16SWG Chapter-5.I.no.5.42.2 ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Sq CM0.380.3835000.0FalseNoneNoneFalseNoneFalse13300.00
3335356117040None5.41.1Supplying and fixing angle iron frame work fabricated out of M.S. angle iron. and M.S. Flat.with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. 40 x 40 x 6 mm Chapter-5, I.no. 5.41.1 ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.m275.0275.015.0FalseNoneNoneFalseNoneFalse4125.00
3335357117040None6.3.1Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system. 48" sweep. (1200mm) Regular model Chapter-6, I.no.6.3.1 ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Each2085.02085.07.0FalseNoneNoneFalseNoneFalse14595.00
3335358117040None6.1Supplying exhaust fan of 1440 RPM of 300 mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply Chapter-6, I.no.6.1 ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Each1542.01542.02.0FalseNoneNoneFalseNoneFalse3084.00
3335359117040None6.12Installation charges for split type air conditioner with allied works for one indoor and one outdoor unit is to be mounted on suitable Angle Iron support upto 3.0 Ton split/cassette type A/C.Chapter-6, I.no.6.12 ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Each4981.04981.02.0FalseNoneNoneFalseNoneFalse9962.00
3335360117040None6.9.3Supplying and installation of insulated refrigerant copper tubing of 5/8" and 3/8" with polythene foam insulation 3 core 80 stand copper wiring between indoor and outdoor unit Leak testing oil and gas charging for additional piping length of tube.Chapter-6, I.no.6.9.3 ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.m1763.01763.04.0FalseNoneNoneFalseNoneFalse7052.00
3335361117040None6.22Extra for Fabrication supply and fixing of Stand fabricated using slotted angle /L angle of size 6mm x 50mm for mounting out door/indoor A.C. unit/ Batteries I NO, 6.22 ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Each4576.04576.02.0FalseNoneNoneFalseNoneFalse9152.00
3335362117040None7.2.1Supplying .litres capacity vertical/horizontal type wall mounting Electrical water heater with 22 SWG copper/SS sheet metal inner Container tinned inside Fiber body outside, filled with glass wool between inner and outer container for thermal insulation complete. The inlet and outlet pipes so arranged that water flow inside results in water to flow out from the inner container without turbulence. The Inner container shall have direct immersion type copper tube nickel plate. 2kW capacity element with a neon indicator fitted with 20A capacity 25 to 85 degree Centigrade range thermostat. The water heater shall completely be wired with 40/0.0076 inch 3 core copper flexible wire of 1.5 meters length and the outer container provided with heavy gauge brackets for wall mounting. 5 Star With Fibre body 25Litres Chapter-7.I.no.7.2.1 ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Each12149.012149.05.0FalseNoneNoneFalseNoneFalse60745.00
3335363117040None8.3Supplying and drawing PVC flexible one pair telephone unarmoured tinned copper cable.2 Pair [Chapter-8,I.no.8.3 ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Mtr42.042.050.0FalseNoneNoneFalseNoneFalse2100.00
3335364117040None9.1.3Supplying, erecting, testing and commissioning of voltage stabilizer suitable for 170 to 270 v input and load variation from no load to full load, with over load protection, spike suppression, operating at 00 C to 400 C. Range etc.,complete.5kVA Capacity Chapter-9, I.no.9.1.3 ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Each4929.04929.02.0FalseNoneNoneFalseNoneFalse9858.00
3335365117040None8.2.2Supplying and drawing PVC flexible one pair telephone unarmoured tinned copper cable 2 Pair I NO : 8.2.2 ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Mtr19.019.050.0FalseNoneNoneFalseNoneFalse950.00
3335366117040None9.2.5Supplying, erecting, testing & commissioning of OFF- LINE UPS system suitable for operation on 230V, 50Hz, A/C supply, with all accessories complete and Excluding batteries and wiring complete.5 kVA OFF LINE UPS I No 9.2.5 ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Each38661.038661.01.0FalseNoneNoneFalseNoneFalse38661.00
3335367117040None9.4.4Supplying, installation, testing & commissioning of 12V .AH batteries in poly propylene container for D.G. sets. Low maintenance batteries, plate type 100 AH capacity I No:9.4.4 ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Each18927.018927.06.0FalseNoneNoneFalseNoneFalse113562.00
3335368117040None11.3.3Supplying of .feet - PVC Batten with integrated LED tube .W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI Greater than 80. Power Input: 220-240V @ 50/60Hz & Power factor greater than 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fighting 1 x4'- 20/22 w Chapter-11.I.no.11.3.3 ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Each740.0740.023.0FalseNoneNoneFalseNoneFalse17020.00
3335369117040None11.4.3Supplying of recess mounting non integrated type LED down light. W luminaire comprising of pressure decast/ extruded aluminium housing, with spring loaded false ceiling clA, LED of Power/COB with CCT 6500 degree K, CRI 70percent efficacy Greaterthan100 lumen per W, 120degree beam spread, life Greaterthan 25000 burning hours and Compliance to IS10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level. LED's are driven by HF electronic driver integrated in a separate control gear assembly., with PF 0.95, power loss shouldlesstah 5percent of lamp Wage, short circuit & open circuit protection to be integrated in the circuit, THD less than 20 Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 15-18W Chapter-11 I.no.11.4.3 ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Each2174.02174.055.0FalseNoneNoneFalseNoneFalse119570.00
3335370117040None13.2.1Supplying and fixing one of 230 volts Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. Chapter-12.I.no.13.2.1 ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Each239.0239.04.0FalseNoneNoneFalseNoneFalse956.00
3335371117040None13.7.1Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. Chapter-13.I.no.13.7.1 ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Each119.0119.088.0FalseNoneNoneFalseNoneFalse10472.00
3335372117040None13.10Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S' hook with fan regulator to the existing board together with supplying and fixing 5 amps. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring. Chapter-13.I.no.13.10 ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Each162.0162.08.0FalseNoneNoneFalseNoneFalse1296.00
3335373117040None13.12Extra length of GI pipe of class B 19mm dia for down rod. Chapter-13.I.no.13.12 ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.m173.0173.010.0FalseNoneNoneFalseNoneFalse1730.00
3335374117040None13.14Fixing one exhaust fan in the nitch already left in the wall with bolts and nuts and 5 A. ceiling rose with sufficient length of 23/0.0076 inch PVC insulated twin core wire. Chapter-13.I.no.13.14 ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Each432.0432.04.0FalseNoneNoneFalseNoneFalse1728.00
3335375117040None13.15.1Erection charges for fixing a . litres capacity wall mounting electric geysers using bolts, flat at one end nut and washers at the other end for through bolts and nuts and washers with 150x450x600mm back plate and wiring complete with 15A 3 pin top. upto 30 Litres Chapter-13.I.no.13.15.1 ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Each648.0648.06.0FalseNoneNoneFalseNoneFalse3888.00
3335376117040None13.2.2Supplying and Fixing.mm dia class A GI pipe bracket upto 2.7 meters long terminated with a reducing collar of 40x25mm to which extra pipe of 175mm length is fixed for fixing MV/SV/MH/FTL street light fitting of all capacities on rail/RCC/wall/tubular pole, using suitable clA, bolts, nuts and wiring using suitable capacity wires Using 32mm dia G.I.Pipe ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Each1136.01136.06.0FalseNoneNoneFalseNoneFalse6816.00
3335377117040None13.2.2Supplying and Fixing.mm dia class A GI pipe bracket upto 2.7 meters long terminated with a reducing collar of 40x25mm to which extra pipe of 175mm length is fixed for fixing MV/SV/MH/FTL street light fitting of all capacities on rail/RCC/wall/tubular pole, using suitable clA, bolts, nuts and wiring using suitable capacity wiresUsing 32mm dia G.I.Pip I NO 13.2.2 ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Each1136.01136.03.0FalseNoneNoneFalseNoneFalse3408.00
3335378117040None11.11.5Supplying & fixing of retrofit type - LED bulb.W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI greaterthan 70percent efficacy greaterthan 80 lumen per watt, life greaterthan 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF greaterthan 0.95, power loss should lessthan 5percent of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20percent Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 12W, 6500K Chapter-11.I.no.11.11.5 ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Each237.0237.020.0FalseNoneNoneFalseNoneFalse4740.00
3335379117040None6.3.1Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system. 48" sweep. (1200mm) Regular model Chapter-6, I.no.6.3.1 ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Each2085.02085.07.0FalseNoneNoneFalseNoneFalse14595.00
3335380117040None3.5.5Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.Chapter-3,I.no. 3.5.5d) 8 Module ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Each302.0302.08.0FalseNoneNoneFalseNoneFalse2416.00
3335381117040None11.8.4Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hrat Lumen Maintenance of 70 percent, maximum light intensity should be between 60 degrees to 70 degrees. CCTgreaterthan 5500K, IP66 optical and electrical compartment & impact resistance of complete luminaire greaterthan IK08. Power Factor greaterthan 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimaltools. LED Light fixture with .W System Power consumption. LED Efficiency greaterthan 1301m/w, nominal CRI greaterthan 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentione LED Streetlight 90 W I No : 11.8.4 ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Each7777.07777.03.0FalseNoneNoneFalseNoneFalse23331.00
3335382117040None9.3.3Supplying, erecting, testing & commissioning of ON-LINE UPS system suitable for operation on 230V, 50Hz, A/C supply, with isolation transformer all accessories complete and Excluding batteries and wiring complete.5 kVA ON LINE UPS ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,complete as per standard technical specification and directions of the Engineer-in-charge of work.Each79172.079172.02.0FalseNoneNoneFalseNoneFalse158344.00
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17192154960000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17192154960000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by any State Government / Government of India /Union Territory.None
17192154960000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17192154960000NoneNoneELIGIBILITYThe bidder is required to ensure browser compatibility of the computer well in advance to the last date and time for receipt of tenders. The departments shall not be responsible for non-accessibility of e-Procurement portal due to internet connectivity issues and technical glitches at bidders end.None
17192154960000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
17192154960000NoneNoneELIGIBILITYBidder shall pay Contract Management Module processing fees of 0.025% of the contact value (Min Rs.500/- & Max Rs.7500/-) soon after contract has been issued to bidder.None
17192154960000NoneNoneELIGIBILITYConditional tenders will not be acceptedNone
17192154960000NoneNoneELIGIBILITYThe tenderer shall bear all costs associated with the preparation and submission of his tender and the employer will in no case be responsible and liable for these costsNone
17192154960000NoneNoneELIGIBILITYThe employer reserves the rights to reject one or all Tender without assigning any reasonsNone
17192154960000NoneNoneELIGIBILITYThe employer is not responsible for any delay in accessing E-Procurement PortalNone
17192154960000NoneNoneELIGIBILITYRoyalty on construction materials and other taxes will be deducted as per prevailing Govt ordersNone
17192154960000NoneNoneELIGIBILITYAs per Government order LD/300/LET/2006 Bangalore dated 1.01.2007 nad Government letter no PW/134/BMS/2007 dated 27.07.2007, a sum amounting to 1% of the bill amount will be deducted towards constructions labour welfare fundNone
17192154960000NoneNoneELIGIBILITYAll the formats prescribed in the bid document shall be filled by the tenderer in complete manner otherwise it will be rejectedNone
17192154960000NoneNoneELIGIBILITYAll scanned documents to be uploaded shall be in original and the Executive Engineer reserves the right to verify the documents before approvalNone
17192154960000NoneNoneELIGIBILITYMaterials required for the work shall be procured by the tenderer themselves and should got tested by the quality control authority before use on the work.None
17192154960000NoneNoneELIGIBILITYContractors should be registered with KPWD Class III and above RegistrationNone
17192154960000NoneNoneELIGIBILITYTo qualify for award of this contract, each tenderer should give all details and documents as per K.W-3None
17192154960000NoneNoneELIGIBILITYWork should be carried out as per K/W-3 STD attached with tender .None
17192154960000NoneNoneELIGIBILITYThe period of completion of this work is 9 MonthsNone
17192154960000NoneNoneELIGIBILITYThe eligible contractor should maintain the work FOR ONE YEAR AFTER THE SUCCESSFUL COMPLETION OF THE PROJECT.None
17192154960000NoneNoneELIGIBILITYContractor shall bound to comply the prevailing rules and regulations with regard to the EPF Contribution rules and any modifications thereof before and after execution of agreementNone
17192154960000NoneNoneELIGIBILITYContractors has to upload the EPF RegistrationNone
17192154960000NoneNoneELIGIBILITYThe FSD deducted in RA bills will be refunded only after successful completion of Defect Liability PeriodNone
17192154960000NoneNoneELIGIBILITYContractors has to submit their labour EPF details with every Running BillNone
17192154960000NoneNoneELIGIBILITYThe Contractor should upload original scanned copy of Purchase invoice/RC Book/Sale Deed duly attested by Notary along with original purchase invoice/Ownership transfer in RC book/Hire or Lease Agreement duly attested by Notary along with original purchase invoice or RC bookNone
17192154960000NoneNoneELIGIBILITYGST shall be paid to executed amount separately.(18% GST is provided in estimate)None
17192154960000NoneNoneELIGIBILITYThe GST shall not be paid in the extended period of contract for which the Contractor alone is responsible for delay as determined by the authority while granting the extension of time.None
17192154960000NoneNoneELIGIBILITYThe contractor belonging to Scheduled Caste should upload Caste Certificate issued by Competent Authority.None
17192154960000NoneNoneELIGIBILITYIf the contractor is a firm, then all the partners or members of the firm shall belong to the Scheduled Caste as the case may be.None
17192154960000NoneNoneELIGIBILITYThe Contractor has to establish site laboratories and should furnish the documents for having required lab testing equipments.None
17192154960000NoneNoneELIGIBILITYSuccessful bidder has to furnish 0.1% of award contract amount as insurance during entering in to agreement.None
17192154960000NoneNoneELIGIBILITYEstimate rates are excluding GST as per common SR 2023-24 and prevailing GST 18Percent of amount put to tender amount is kept in the form of lumpsum in sanctioned estimate according to guidelines in Common SR.Therefore amount put to tender and ECV amount are excluding GST.None
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneTo qualify for award of this contract, each Tenderer in his name should have in the last five years i.e., 2019-20, 2020-21,2021-22, 2022-23 23-24 Mandating Satisfactorily completion as prime contractor, for atleast any construction work of value not less than Rs.14.20lakhs(Updated to 2024-25 Price Level)Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Certificate issued from the competent authority not below the rank of Executive Engineer
NoneNoneNoneNoneThe tenderer or his identified sub contractor should possess required valid electrical license for executing building electrification works and should have executed similar works totaling Rs.2.23 lakhs in any one year during last five years i.e., 2019-20, 2020-21, 2021-22, 2022-23,23-24 (Updated to 2024-25 Price level)Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- certificate issued from the competent authority not below the rank of Executive Engineer
NoneNoneNoneNoneThe tenderer or his identified sub contractor should possess required valid license for executing building water supply/ sanitary works and should have executed similar works totaling Rs 1.54 lakhs in any one year during last five years i.e., 2019-20, 2020-21, 2021-22, 2022-23,23-24 Updated to 2024-25 Price levelPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- certificate issued from the competent authority not below the rank of Executive Engineer
NoneNoneNoneNoneExecuted in any one year i.e 2019-20, 2020-21,2021-22 , 2022-23, 23-24 the following minimum quantities of work 1. Earth work 150.67Cum 2.Cement Concrete 82.02 Cum 3. BBM/Cement blocks : 75.33Cum4.Plastering 803.76 Sqm 5. Flooring 262.33Sqm 6. Steel 7.47Tons 7. Painting:1573.14SqmPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- certificate issued from from the competent authority not below the rank of Executive Engineer
NoneNoneNoneNoneTenderers who meet the above specified minimum qualifying criteria, will only be qualified, if their available tender capacity is more than the total tender value. The available tender capacity will be calculated as under : Assessed available tender capacity:(AxNx5.00 -B ) should be greater than or equal to Rs.56.75lakhs where A-Maximum value of works executed in any one year during the last five years taking into account the completed as well as works in progress. (updated to 2024-25 price level) N-Number of years prescribed for completion of the works for which tenders are invited-9 Months. B-Value, at 2024-25 price level, of existing commitments and on-going works to be completed during the next 9 Months. (Period of completion of the works for which tenders are invited)Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Submit information as per Section 3 of Tender Document
NoneNoneNoneNoneTo qualify for award of this contract, each Tenderer in his name should have in the last five years i.e., 2019-20, 2020-21,2021-22 , 2022-23, 23-24 Achieved in atleast one financial years a minimum financial turnover of Rs 56.75Lakhs(Updated to 2024-25 Price Level)Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Balance Sheets, Profit & Loss Statements certified from an Registered Chartered Accountant with UDIN
NoneNoneNoneNoneliquid assets and /or availability of credit facilities of not less than Rs17.03lakhs (credit lines / letter of credit/ certificates from Nationalized banks) for meeting the fund requirement etc (The fomat should be as per KW-3 Bid document Section-3 Para 1.10)Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Bankers certificate in the prescribed format issued by Nationalised Bank
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Annual Turnover Certificate certificate issued by Approved Chartered Accountant with UDIN i.e., 2019-20, 2020-21,2021-22 , 2022-23, 23-24 as per KW-3 Rs.56.75lakhsTrueTechnical Bid
KPWD Class-III and above above Registration CertificateTrueTechnical Bid
The contractor belonging to Scheduled Caste should upload Caste Certificate issued by Competent Authority.TrueTechnical Bid
The contractor belonging to Scheduled Caste shall be domicile of the State of Karnataka for more than 10 years Should upload Certificate issued by Competent Authority.TrueTechnical Bid
Work done certificate as per KW-3-25 percent amount put to tender i.e., Rs.14.20lakhs certificate should be issued not below the rank of Executive EngineerTrueTechnical Bid
Line of credit as per KW-3 Rs.17.03lakhsTrueTechnical Bid
Contractors has to upload the EPF RegistrationTrueTechnical Bid
tenderWorkLocationList
tenderAddressNone
tenderRecallDTONone