createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1718963050817
version3
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee4860.00
emd292000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose10-07-2024 16:00:00
tenderQueryClose04-07-2024 16:00:00
technicalBidOpen11-07-2024 16:01:00
publishedDate24-06-2024 15:55:48
publishedByPostEWHFWD_CE_CEOFF_BNG
publishedByUserKPE16838 - BALEKATTE KUMARASWAMY PAVITHRA
bidValidityPeriod90
noOfCalls1
preBidMeetingDate06-07-2024 11:00:00
preBidMeetingYnTrue
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonGnanesh Kumar V P
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumber08029557023
mobileNumber9686183379
tenderSupplierListNone
tenderSchedule
createdTs1718963050846
version4
createdDateNone
modifiedDateNone
tenderNumberEWHFWD/2024-25/BD/WORK_INDENT505
titleConstruction of Health and Welness Center at Kuttabad in Bidar Taluk,Bidar District.(2)Construction of Health and Welness Center at Chandori in Aurad Taluk,Bidar District.(3)Construction of Health and Welness Center at Madnoor in Aurad Taluk,Bidar District
description1)Construction of Health and Welness Center at Kuttabad in Bidar Taluk,Bidar District.(2)Construction of Health and Welness Center at Chandori in Aurad Taluk,Bidar District.(3)Construction of Health and Welness Center at Madnoor in Aurad Taluk,Bidar District
categoryWORKS
categoryTextWorks
ecv19416523.80
deptNameEngineering Wing of Health and Family Welfare Department
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnFalse
location3521
locationNameEWHFWD Chief Engineer Office Bengaluru
provisionalAmount19500000.0
groupOverheadTotalNone
fileNumberEWHFWD/2023-24/BD/HWC/PACKAGE/BR
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17189630510000NoneNoneBuildings1 Construction of Health and Welness Center at Kuttabad in Bidar Taluk,Bidar District.(civil works-GF))4113889.86
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3327593116573NoneVol - III, P. no. 9, it. No. 2.5.ii.aClearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. Sq4.864.86750.0FalseNoneNoneFalseNoneFalse3645.00
3327594116573NoneVol - I, P. no. 8, It. No. 1.12Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. Cum117.71117.7175.0FalseNoneNoneFalseNoneFalse8828.250
3327595116573NoneVol - I, P. no. 8, It. No. 1.14Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work Cum126.38126.38221.3FalseNoneNoneFalseNoneFalse27967.8940
3327596116573NoneVol - I, P. no. 15, It. No. 2.1.3,Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. - Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates Cum7420.377420.3724.52FalseNoneNoneFalseNoneFalse181947.47240
3327597116573NoneVol - I, P. no. 15, It. No. 2.2.1Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/ trap/basalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) - M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Footings,Pedestal,Screed concrete over slab Cum7789.597789.5937.57FalseNoneNoneFalseNoneFalse292654.89630
3327598116573NoneVol - I, P. no. 7, It. No. 1.9Filling available excavated earth (excluding rock) in trenches, plinth,sides of foundations and other similar works etc. in layers not exceeding 0cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. Cum329.57329.57177.04FalseNoneNoneFalseNoneFalse58347.07280
3327599116573NoneVol - I, P. no. 7, It. No. 1.8Construction of Embankment by excavating the available approved Gravel/ Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. Cum587.29587.29198.61FalseNoneNoneFalseNoneFalse116641.66690
3327600116573NoneVol - II, P. no. 9, It. No. 5.1.1Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : Cement mortar 1:6 (1 cement : 6 coarse sand) Cum6952.036952.037.2FalseNoneNoneFalseNoneFalse50054.6160
3327601116573NoneVol - II, P. no. 9, It. No. 5.3Providing Coursed rubble masonry (second sort) with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) Cum7688.07688.05.4FalseNoneNoneFalseNoneFalse41515.20
3327602116573NoneVol - I, P. no. 16, It. No. 2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Cum8478.488478.4844.67FalseNoneNoneFalseNoneFalse378733.70160
3327603116573NoneVol - I, P. no. 111,Appendix I-Additionalities for Formwork, Centering & Scaffolding - Including cost of all materials, labours, HOM, I & UL, Curing with all lead and lifts etc. complete as per specifications and as directed by engineer-in-charge of the work. Footings Pedestal Cum623.17623.1729.44FalseNoneNoneFalseNoneFalse18346.12480
3327604116573NoneVol - I, P. no. 111,Appendix I-Additionalities for Formwork, Centering & Scaffolding - Including cost of all materials, labours, HOM, I & UL, Curing with all lead and lifts etc. complete as per specifications and as directed by engineer-in-charge of the work. COLUMNS Cum5934.935934.939.18FalseNoneNoneFalseNoneFalse54482.65740
3327605116573NoneVol - I, P. no. 111Appendix I-Additionalities for Formwork, Centering & Scaffolding - Including cost of all materials, labours, HOM, I & UL, Curing with all lead and lifts etc. complete as per specifications and as directed by engineer-in-charge of the work. PLINTH BEAM,Columns embedded in Plinth Beam Cum4239.244239.248.86FalseNoneNoneFalseNoneFalse37559.66640
3327606116573NoneVol - I, P. no. 111Appendix I-Additionalities for Formwork, Centering & Scaffolding - Including cost of all materials, labours, HOM, I & UL, Curing with all lead and lifts etc. complete as per specifications and as directed by engineer-in-charge of the work. LINTELS ROOF BEAM CONCRETE Cum5087.095087.0912.29FalseNoneNoneFalseNoneFalse62520.33610
3327607116573NoneVol - I, P. no. 111Appendix I-Additionalities for Formwork, Centering & Scaffolding - Including cost of all materials, labours, HOM, I & UL, Curing with all lead and lifts etc. complete as per specifications and as directed by engineer-in-charge of the work. ROOF SLAB Cum4239.244239.2414.08FalseNoneNoneFalseNoneFalse59688.49920
3327608116573NoneVol - I, P. no. 111Appendix I-Additionalities for Formwork, Centering & Scaffolding - Including cost of all materials, labours, HOM, I & UL, Curing with all lead and lifts etc. complete as per specifications and as directed by engineer-in-charge of the work. Chajja Cum3815.313815.311.03FalseNoneNoneFalseNoneFalse3929.76930
3327609116573NoneVol - I, P. no. 15, It. No. 2.1.6Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. - Mix 1:2:4 Using 20 mm nominal size graded crushed coarse aggregates Cill Concrete Cum7735.087735.081.69FalseNoneNoneFalseNoneFalse13072.28520
3327610116573NoneVol - 1, P. no.18, It. No. 2.11 aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.t110837.22110837.228.55FalseNoneNoneFalseNoneFalse947658.2310
3327611116573NoneVol - II, P. No. 14, It. No. 6.8Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. Ground Floor Wall - Upto Slab Beam Bottom Cum9873.599873.5937.38FalseNoneNoneFalseNoneFalse369074.79420
3327612116573NoneVol - II, P. No. 14, It. No. 6.13Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:4 (1 cement :4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. Sqm1209.261209.2635.55FalseNoneNoneFalseNoneFalse42989.1930
3327613116573NoneVol - II, P. No. 100, It. No. 12.13.1Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. Cum122431.79122431.790.45FalseNoneNoneFalseNoneFalse55094.30550
3327614116573NoneVol - II, P. No. 104, It. No. 12.51Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. Each1258.821258.824.0FalseNoneNoneFalseNoneFalse5035.280
3327615116573NoneVol - II, P. No. 219, It. No. 22.15.4Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge - SS Aldrop 16mm dia, 300mm Each464.63464.634.0FalseNoneNoneFalseNoneFalse1858.520
3327616116573NoneVol - II, P. No. 219, It. No. 22.15.1Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge - SS Handles 200mm Each557.55557.558.0FalseNoneNoneFalseNoneFalse4460.40
3327617116573NoneVol - II, P. No. 219, It. No. 22.15.6Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge - SS Tower Bolts 200x10mm Each185.85185.854.0FalseNoneNoneFalseNoneFalse743.40
3327618116573NoneVol - II, P. No. 219, It. No. 22.15.8Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge - SS hinges 125 mm Each61.9561.9516.0FalseNoneNoneFalseNoneFalse991.20
3327619116573NoneVol - II, P. No. 69, It. No. 10.6.2Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm Each68.1568.1512.0FalseNoneNoneFalseNoneFalse817.80
3327620116573NoneVol - II, P. No. 205, It. No. 20.79Supplying and fixing new teak wood beads wherever necessary including cost of materials, labour, complete as per specifications. Each64.4364.4324.0FalseNoneNoneFalseNoneFalse1546.320
3327621116573NoneVol - II, P. No. 105, It. No. 12.57.6Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 35 mm thick both side commercial Each4115.964115.9615.36FalseNoneNoneFalseNoneFalse63221.14560
3327622116573NoneVol - II, P. No. 110, It. No. 12.89Providing & fixing of 2.5 track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 94mm width x 45mm height with reinforcement of 1mm thickness and Sash with overall size of 39mm x 58mm with GI reinforcement of 1.5mm and mesh sash of size 25mm x 42mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 1819mm x 1819mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)Sqm8116.698116.699.84FalseNoneNoneFalseNoneFalse79868.22960
3327623116573NoneVol - II, P. No. 109, It. No. 12.85Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) Sqm7085.847085.840.72FalseNoneNoneFalseNoneFalse5101.80480
3327624116573NoneVol - II, P. No. 85, It. No. 11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding Kg208.15208.15206.64FalseNoneNoneFalseNoneFalse43012.1160
3327625116573NoneVol - II, P. No. 111, It. No. 12.93.1Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately) - Size 62 x 100mm Rmtr869.78869.789.8FalseNoneNoneFalseNoneFalse8523.8440
3327626116573NoneVol - II, P. No. 112, It. No. 12.94.1Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately) - 30 mm thickness Cum4317.924317.923.15FalseNoneNoneFalseNoneFalse13601.4480
3327627116573NoneVol - II, P. No. 42, It. No. 8.5.2Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sqm432.41432.41241.84FalseNoneNoneFalseNoneFalse104574.03440
3327628116573NoneVol - II, P. No. 43, It. No. 8.10Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sqm261.43261.4393.2FalseNoneNoneFalseNoneFalse24365.2760
3327629116573NoneVol - II, P. No. 50, It. No. 8.51Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. Sqm123.9123.9335.04FalseNoneNoneFalseNoneFalse41511.4560
3327630116573NoneVol - II, P. No. 42, It. No. 8.8Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (outside) Sqm459.67459.67163.75FalseNoneNoneFalseNoneFalse75270.96250
3327631116573NoneVol - II, P. No. 43, It. No. 8.16.1Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment Sqm42.1342.13676.2FalseNoneNoneFalseNoneFalse28488.3060
3327632116573NoneVol - II, P. No. 54, It. No. 8.79Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove. Rmtr64.4364.43271.01FalseNoneNoneFalseNoneFalse17461.17430
3327633116573NoneVol - II, P. No. 60, It. No. 9.12.2Providing and laying vitrified floor tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm Sqm1418.661418.6656.4FalseNoneNoneFalseNoneFalse80012.4240
3327634116573NoneVol - II, P. No. 40, It. No. 8.2.2Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sqm345.68345.6867.22FalseNoneNoneFalseNoneFalse23236.60960
3327635116573NoneVol - II, P. No. 60, It. No. 9.11Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thick- ness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. Sqm1101.471101.475.98FalseNoneNoneFalseNoneFalse6586.79060
3327636116573NoneVol - II, P. No. 64, It. No. 9.39Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. Sqm1795.311795.3167.22FalseNoneNoneFalseNoneFalse120680.73820
3327637116573NoneVol - II, P. No. 48, It. No. 8.39Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sqm157.35157.35335.04FalseNoneNoneFalseNoneFalse52718.5440
3327638116573NoneVol - II, P. No. 46, It. No. 8.31Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives with pure Acrylic Resin, UV resistant, dirt & pick up resistant, Alkali & Water resistant of required shade: New work (Two coats applied @ 1.43 L/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sqm220.54220.54163.75FalseNoneNoneFalseNoneFalse36113.4250
3327639116573NoneVol - II, P. No. 48, It. No. 8.40Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sqm142.49142.4962.22FalseNoneNoneFalseNoneFalse8865.72780
3327640116573NoneVol - II, P. No. 48, It. No. 8.38Painting with oil type wood preservative of approved brand and manufacture :New work (two coats) to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sqm49.5649.5625.2FalseNoneNoneFalseNoneFalse1248.9120
3327641116573NoneVol - II, P. No. 48, It. No. 9.24Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cat Eye, River Pink or equivalent.Sqm3533.633533.6351.69FalseNoneNoneFalseNoneFalse182653.33470
3327642116573NoneVol - II, P. No. 48, It. No. 9.24Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. Kg700.04700.04234.0FalseNoneNoneFalseNoneFalse163809.360
3327643116573NoneVol - II, P. No. 87, It. No. 11.35.1.1Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For Fixed Portion : Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) including cost of materials, labour, usage charges of machinery complete as per specifications. Kg560.03560.0388.2FalseNoneNoneFalseNoneFalse49394.6460
3327644116573NoneLUMPSUMThe Tenderer (agency) should arrange to obtain (get), detailed Architectural drawings and elevations, Structural designs and drawings including Soil exploration and providing consultancy for Architectural designs & drawings, elevation, 3D view, Internal and External Electrical services including electrical infrastructure , Lifts, CCTV/Net working system interior layout and liaison with other department and approval of pollution control board and allied works etc., and any other drawings related to this project (This item is included in schedule B as a item) and 6 sets of as built drawings should be submitted to the employer. The Consultancy Fees which is included as an item in schedule B shall be paid on prorate basis of the main work or by negotiation with the employer. - - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge Lump Sum for Each43365.043365.01.0FalseNoneNoneFalseNoneFalse43365.00
17189630510000NoneNoneBuildings1 Construction of Health and Welness Center at Kuttabad in Bidar Taluk,Bidar District.(Civil works -First Floor)1723935.87
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3327645116574NoneVol - I, P. no. 16, It. No. 2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Cum8559.228559.2220.89FalseNoneNoneFalseNoneFalse178802.10580
3327646116574NoneVol - I, P. no. 111Appendix I-Additionalities for Formwork, Centering & Scaffolding - Including cost of all materials, labours, HOM, I & UL, Curing with all lead and lifts etc. complete as per specifications and as directed by engineer-in-charge of the work FIRST FLOOR COLUMNS PARAPET COLUMNS Cum5991.465991.463.47FalseNoneNoneFalseNoneFalse20790.36620
3327647116574NoneVol - I, P. no. 111Appendix I-Additionalities for Formwork, Centering & Scaffolding - Including cost of all materials, labours, HOM, I & UL, Curing with all lead and lifts etc. complete as per specifications and as directed by engineer-in-charge of the work. Lintel Concrete FIRST FLOOR ROOF BEAM CONCRETE Cum5135.535135.535.85FalseNoneNoneFalseNoneFalse30042.85050
3327648116574NoneVol - I, P. no. 111,Appendix I-Additionalities for Formwork, Centering & Scaffolding - Including cost of all materials, labours, HOM, I & UL, Curing with all lead and lifts etc. complete as per specifications and as directed by engineer-in-charge of the work. ROOF SLAB Cum4279.614279.6118.49FalseNoneNoneFalseNoneFalse79129.98890
3327649116574NoneVol - I, P. no. 111Appendix I-Additionalities for Formwork, Centering & Scaffolding - Including cost of all materials, labours, HOM, I & UL, Curing with all lead and lifts etc. complete as per specifications and as directed by engineer-in-charge of the work. Chajja Cum3851.653851.650.26FalseNoneNoneFalseNoneFalse1001.4290
3327650116574NoneVol - I, P. no. 15, It. No. 2.1.6Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. - Mix 1:2:4 Using 20 mm nominal size graded crushed coarse aggregates Cum7808.747808.741.69FalseNoneNoneFalseNoneFalse13196.77060
3327651116574NoneVol - 1, P. no.18, It. No. 2.11 aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.t111892.82111892.822.56FalseNoneNoneFalseNoneFalse286445.61920
3327652116574NoneVol - II, P. No. 14, It. No. 6.8Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. Cum9967.639967.6322.8FalseNoneNoneFalseNoneFalse227261.9640
3327653116574NoneVol - II, P. No. 14, It. No. 6.13Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:4 (1 cement :4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. Sqm1220.781220.7845.11FalseNoneNoneFalseNoneFalse55069.38580
3327654116574NoneVol - II, P. No. 100, It. No. 12.13.1Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. Cum123597.8123597.80.45FalseNoneNoneFalseNoneFalse55619.010
3327655116574NoneVol - II, P. No. 104, It. No. 12.51Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. Each1270.811270.814.0FalseNoneNoneFalseNoneFalse5083.240
3327656116574NoneVol - II, P. No. 219, It. No. 22.15.4Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge - SS Aldrop 16mm dia, 300mm Each469.05469.054.0FalseNoneNoneFalseNoneFalse1876.20
3327657116574NoneVol - II, P. No. 219, It. No. 22.15.1Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge - SS Handles 200mm Each562.86562.868.0FalseNoneNoneFalseNoneFalse4502.880
3327658116574NoneVol - II, P. No. 219, It. No. 22.15.6Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge - SS Tower Bolts 200x10mm Each187.62187.624.0FalseNoneNoneFalseNoneFalse750.480
3327659116574NoneVol - II, P. No. 219, It. No. 22.15.8Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge - SS hinges 125 mm Each62.5462.5416.0FalseNoneNoneFalseNoneFalse1000.640
3327660116574NoneVol - II, P. No. 69, It. No. 10.6.2Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm Each68.7968.7912.0FalseNoneNoneFalseNoneFalse825.480
3327661116574NoneVol - II, P. No. 205, It. No. 20.79Supplying and fixing new teak wood beads wherever necessary including cost of materials, labour, complete as per specifications. No65.0465.0424.0FalseNoneNoneFalseNoneFalse1560.960
3327662116574NoneVol - II, P. No. 105, It. No. 12.57.6Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 35 mm thick both side commercial Sqm4155.164155.1615.36FalseNoneNoneFalseNoneFalse63823.25760
3327663116574NoneVol - II, P. No. 110, It. No. 12.89Providing & fixing of 2.5 track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 94mm width x 45mm height with reinforcement of 1mm thickness and Sash with overall size of 39mm x 58mm with GI reinforcement of 1.5mm and mesh sash of size 25mm x 42mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 1819mm x 1819mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) Sqm8193.998193.999.6FalseNoneNoneFalseNoneFalse78662.3040
3327664116574NoneVol - II, P. No. 109, It. No. 12.85Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) Sqm7153.337153.330.72FalseNoneNoneFalseNoneFalse5150.39760
3327665116574NoneVol - II, P. No. 85, It. No. 11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding Kg210.13210.13206.64FalseNoneNoneFalseNoneFalse43421.26320
3327666116574NoneVol - II, P. No. 111, It. No. 12.93.1Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately) - Size 62 x 100mm Rmtr878.06878.069.8FalseNoneNoneFalseNoneFalse8604.9880
3327667116574NoneVol - II, P. No. 112, It. No. 12.94.1Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately) - 30 mm thickness Cum4359.044359.043.15FalseNoneNoneFalseNoneFalse13730.9760
3327668116574NoneVol - II, P. No. 42, It. No. 8.5.2Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sqm436.53436.53141.19FalseNoneNoneFalseNoneFalse61633.67070
3327669116574NoneVol - II, P. No. 43, It. No. 8.10Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sqm263.92263.9272.81FalseNoneNoneFalseNoneFalse19216.01520
3327670116574Noneol - II, P. No. 50, It. No. 8.51Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. Sqm125.08125.08214.0FalseNoneNoneFalseNoneFalse26767.120
3327671116574NoneVol - II, P. No. 42, It. No. 8.8Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (outside) Sqm464.05464.05146.23FalseNoneNoneFalseNoneFalse67858.03150
3327672116574NoneVol - II, P. No. 43, It. No. 8.16.1Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment Sqm42.5342.53676.2FalseNoneNoneFalseNoneFalse28758.7860
3327673116574NoneVol - II, P. No. 54, It. No. 8.79Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove. Rmtr65.0465.04271.01FalseNoneNoneFalseNoneFalse17626.49040
3327674116574NoneVol - II, P. No. 60, It. No. 9.12.2Providing and laying vitrified floor tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm Sqm1432.171432.1752.46FalseNoneNoneFalseNoneFalse75131.63820
3327675116574NoneVol - II, P. No. 40, It. No. 8.2.2Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sqm348.97348.9767.22FalseNoneNoneFalseNoneFalse23457.76340
3327676116574NoneVol - II, P. No. 60, It. No. 9.11Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thick- ness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. Sqm1111.961111.965.98FalseNoneNoneFalseNoneFalse6649.52080
3327677116574NoneVol - II, P. No. 64, It. No. 9.39Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. Sqm1812.411812.416.3FalseNoneNoneFalseNoneFalse11418.1830
3327678116574NoneVol - II, P. No. 48, It. No. 8.39Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sqm158.85158.85214.0FalseNoneNoneFalseNoneFalse33993.90
3327679116574NoneVol - II, P. No. 46, It. No. 8.31Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives with pure Acrylic Resin, UV resistant, dirt & pick up resistant, Alkali & Water resistant of required shade: New work (Two coats applied @ 1.43 L/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sqm222.64222.64146.23FalseNoneNoneFalseNoneFalse32556.64720
3327680116574NoneVol - II, P. No. 48, It. No. 8.40Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sqm143.84143.8462.22FalseNoneNoneFalseNoneFalse8949.72480
3327681116574NoneVol - II, P. No. 48, It. No. 8.38Painting with oil type wood preservative of approved brand and manufacture :New work (two coats) to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sqm50.0350.0325.2FalseNoneNoneFalseNoneFalse1260.7560
3327682116574NoneVol - II, P. No. 48, It. No. 9.24Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cat Eye, River Pink or equivalent. Sqm3567.283567.2813.5FalseNoneNoneFalseNoneFalse48158.280
3327683116574NoneVol - II, P. No. 48, It. No. 9.24Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. Kg706.7706.7119.07FalseNoneNoneFalseNoneFalse84146.7690
17189630510000NoneNoneBuildings1 Construction of Health and Welness Center at Kuttabad in Bidar Taluk,Bidar District.(Internal water supply & sanitary works)196185.86
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3327684116575NoneV-II, P. No. 28, It. No. 14.28.2.2Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. 40mm dia pipes, From wash basin waste lines Rmtr113.99113.994.0FalseNoneNoneFalseNoneFalse455.960
3327685116575NoneVol - V, P. no. 120, It. No. 10.14.9Providing and installing at site of work P.V.C. pipes including cost of pipes and specials and labour, including lowering into trenches, laying true to line, level and perfect linking at joints leak proof including jointing of approved type with all labour charges and all lift charges, handling charges including encasing the pipe around to a depth not less than 15 cms with gravel or selected earth available from the excavation etc. complete. PVC pipe - 75mm(weight of pipe -0.917 kg) Rmtr237.89237.8920.0FalseNoneNoneFalseNoneFalse4757.80
3327686116575NoneVol - V, P. no. 120, It. No. 10.14.11PVC pipe - OD 110mm and 6 Kg/sqcm, sanitary lines Rmtr443.56443.5650.0FalseNoneNoneFalseNoneFalse22178.00
3327687116575NoneVol - II, P. no. 136, It. No. 14.31Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. No1511.581511.584.0FalseNoneNoneFalseNoneFalse6046.320
3327688116575NoneVol - II, P. no. 123, It. No. 14.3.1Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid Each7405.57405.54.0FalseNoneNoneFalseNoneFalse29622.00
3327689116575NoneVol - II, P. no. 117, It. No. 13.3.1Providing and fixing brass stop cock of approved quality : 15 mm nominal bore Each370.46370.464.0FalseNoneNoneFalseNoneFalse1481.840
3327690116575NoneVol - II, P. no. 132, It. No. 14.7.1Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15mm C.P. brass pillar taps Each3818.63818.64.0FalseNoneNoneFalseNoneFalse15274.40
3327691116575NoneVol - II, P. No. 122, it. No. 13.32.2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. Rmtr469.58469.5860.0FalseNoneNoneFalseNoneFalse28174.80
3327692116575NoneVol - II, P. No. 122, It. No. 13.33.2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) External & Shafts & Terrace 20 mm nominal dia Pipes Rmtr268.86268.8620.0FalseNoneNoneFalseNoneFalse5377.20
3327693116575NoneVol - II, P. No. 122, It. No. 13.33.3Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) External & Shafts & Terrace 25 mm nominal dia Pipes Rmtr366.74366.7450.0FalseNoneNoneFalseNoneFalse18337.00
3327694116575NoneVol - V, P. No. 191, It. No. 16.9Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.(CATCH BASIN) No6757.516757.516.0FalseNoneNoneFalseNoneFalse40545.060
3327695116575NoneVol - II, P. no. 123, It. No. 13.34Providing and placing on terrace (at all floor levels) polyethylene water storage tank,IS:12701 marked,with cover and suitable locking arrangement and making necessary holes for inlet,outlet and overflow pipes but without fittings and the base support for tank. Ltr11.1511.152000.0FalseNoneNoneFalseNoneFalse22300.00
3327696116575NoneVol - II, P. no. 127, It. No. 13.59Providing and fixing PVC (S.W.R) Nahani Trap 10cms x 10cms with all fitting arrangements & all necessary accessories complete Ground Toilet 10Cms X 7.5Cms No272.58272.586.0FalseNoneNoneFalseNoneFalse1635.480
17189630510000NoneNoneBuildings1 Construction of Health and Welness Center at Kuttabad in Bidar Taluk,Bidar District.(Internal Electrification)438163.01
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3327697116576NoneCSR 2023-24 It.No 2.02.01Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point up to 3Mtr from tapping point to out let via switch Pack317.42317.4220.0FalseNoneNoneFalseNoneFalse6348.40
3327698116576NoneCSR 2023-24 It.No 2.2.2Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Medium point above 3mtr up to 6Mtr from tapping point to out let via switch Pack447.22447.2215.0FalseNoneNoneFalseNoneFalse6708.30
3327699116576NoneCSR 2023-24 It.No 2.2.3Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Above 6Mtr up to 10Mtr from tapping Point to out let via switch Pack654.9654.910.0FalseNoneNoneFalseNoneFalse6549.00
3327700116576NoneCSR 2023-24 It.No 3.4.2Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall Each187.62187.624.0FalseNoneNoneFalseNoneFalse750.480
3327701116576NoneCSR 2023-24 It.No 3.4.3Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 4-5Way Each208.86208.862.0FalseNoneNoneFalseNoneFalse417.720
3327702116576NoneCSR 2023-24 It.No 3.4.4Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 6Way Each259.6259.610.0FalseNoneNoneFalseNoneFalse2596.00
3327703116576NoneCSR 2023-24 It.No 3.4.5Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 8Way Each307.98307.985.0FalseNoneNoneFalseNoneFalse1539.90
3327704116576NoneCSR 2023-24 It.No 3.4.6Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 10-12Way Each376.42376.4210.0FalseNoneNoneFalseNoneFalse3764.20
3327705116576NoneCSR 2023-24 It.No 3.5.2Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 3 Module Each189.98189.984.0FalseNoneNoneFalseNoneFalse759.920
3327706116576NoneCSR 2023-24 It.No 3.5.3Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 4 Module Each276.12276.1210.0FalseNoneNoneFalseNoneFalse2761.20
3327707116576NoneCSR 2023-24, It.No 3.5.5Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 8 Module Each335.12335.125.0FalseNoneNoneFalseNoneFalse1675.60
3327708116576NoneCSR 2023-24 It.No 3.5.6Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 10-12 Module Each405.92405.9210.0FalseNoneNoneFalseNoneFalse4059.20
3327709116576NoneCSR 2023-24 It.No 3.6.1Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps one way. Each120.36120.36120.0FalseNoneNoneFalseNoneFalse14443.20
3327710116576NoneCSR 2023-24 It.No 3.6.3Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps 3way socket. Each201.78201.7820.0FalseNoneNoneFalseNoneFalse4035.60
3327711116576NoneCSR 2023-24, It.No 3.6.4Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Stepped Fan Regulator. Each421.26421.2610.0FalseNoneNoneFalseNoneFalse4212.60
3327712116576NoneCSR 2023-24, It.No 3.6.8Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 16Amps one way switch Each212.4212.420.0FalseNoneNoneFalseNoneFalse4248.00
3327713116576NoneCSR 2023-24 It.No 3.6.10Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 32Amps DP switch Each384.68384.684.0FalseNoneNoneFalseNoneFalse1538.720
3327714116576NoneCSR 2023-24 It.no 3.6.11Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6/16Amps universal socket Each278.48278.4810.0FalseNoneNoneFalseNoneFalse2784.80
3327715116576NoneCSR 2023-24 It.No 3.6.12Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. TV/Telephone socket Each184.08184.082.0FalseNoneNoneFalseNoneFalse368.160
3327716116576NoneCSR 2023-24 It.No 1.13Supplyin and Fixing Metal Fan Box with Round Hook. No138.06138.0610.0FalseNoneNoneFalseNoneFalse1380.60
3327717116576NoneCSR 2023-24 P.No 1.2.1Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 19/20mm dia 2mm thick Rmtr77.8877.8890.0FalseNoneNoneFalseNoneFalse7009.20
3327718116576NoneCSR 2023-24 It.No 1.2.2Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 25mm dia 2mm thick Rmtr92.0492.04150.0FalseNoneNoneFalseNoneFalse13806.00
3327719116576NoneCSR 2023-24 It.No 1.2.3Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 32mm dia 2mm thick Rmtr121.54121.5430.0FalseNoneNoneFalseNoneFalse3646.20
3327720116576NoneCSR 2023-24 It.No 1.7.1Extra for Groove cutting in brick wall/CC floor to the suitable depth for concealing of Conduit/GI pipe and plastering, finishing upto wall surface completeRmtr34.2234.2260.0FalseNoneNoneFalseNoneFalse2053.20
3327721116576NoneCSR 2023-24 It.No 2.3.2Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5 sqmm Rmtr30.6830.68180.0FalseNoneNoneFalseNoneFalse5522.40
3327722116576NoneCSR 2023-24 It.No 2.3.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.5 sqmm Rmtr49.5649.561080.0FalseNoneNoneFalseNoneFalse53524.80
3327723116576NoneCSR 2023-24 It.No 2.3.4Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 4 sqmm Rmtr74.3474.34360.0FalseNoneNoneFalseNoneFalse26762.40
3327724116576NoneCSR 2023-24 It.No 5.19.4Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure( Double Door) 12 Way SP & NEach2198.342198.342.0FalseNoneNoneFalseNoneFalse4396.680
3327725116576NoneCSR 2023-24 It.No 5.18.1Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32 A SPEach489.7489.720.0FalseNoneNoneFalseNoneFalse9794.00
3327726116576NoneCSR 2023-24 It.No 5.18.4Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898" 6-32 A DP Each872.02872.022.0FalseNoneNoneFalseNoneFalse1744.040
3327727116576None19-20SR P.No 6.4.4Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975 4 core 16 sqmm Km167373.56167373.560.25FalseNoneNoneFalseNoneFalse41843.390
3327728116576NoneCSR 2023-24 P.No 11.3.2Supplying of .feet - PVC Batten with integrated LED tube .W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. Each814.2814.220.0FalseNoneNoneFalseNoneFalse16284.00
3327729116576NoneCSR 2023-24 It.No 11.4.1Supplying & fixing of retrofit type - LED bulb.W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70%. efficacy 80 lumen per watt, life25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 5-6 W,Each949.9949.96.0FalseNoneNoneFalseNoneFalse5699.40
3327730116576NoneCSR 2023-24 It.No 6.1Supplying exhaust fan of 1440 RPM of 300mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply. Each1760.561760.566.0FalseNoneNoneFalseNoneFalse10563.360
3327731116576NoneCSR 2023-24 It.No 6.3.1Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system. 48" Sweep (1200mm) Regular model Each3521.123521.1210.0FalseNoneNoneFalseNoneFalse35211.20
3327732116576NoneCSR 2023-24 P.No 13.7.1Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall / ceiling / Rafter / Girders Each143.96143.9620.0FalseNoneNoneFalseNoneFalse2879.20
3327733116576NoneCSR 2023-24 It.No13.10Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S' hook with fan regulator to the existing board together with supplying and fixing 5 amps. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring. Each201.78201.7810.0FalseNoneNoneFalseNoneFalse2017.80
3327734116576NoneCSR 2023-34 13.13Fixing one exhaust fan after making a suitable nitch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 amps, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame. Each834.26834.266.0FalseNoneNoneFalseNoneFalse5005.560
3327735116576NoneCSR 2023-34 It.No 11.8.2Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with .W System Power consumption. LED Efficiency130lm/w, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Streetlight 40watts No4748.324748.322.0FalseNoneNoneFalseNoneFalse9496.640
3327736116576NoneCSR 2023-24 IT.No 13.4.1Supplying and fixing telescopic M.S. bracket fabricated by using 0.5m length 4” dia telescopic M. S. pipe, with 2” dia 1.5m long M. S. bracket and are welded with suitable angle, using 6mm thick M. S. sheet, grip bolts & nuts, as required, suitable for 9 to 12 Mtrs. M. S. tubular pole, with necessary two coats of painting, with all other accessories. Single bracket 1.5 Mtr. Length Each1723.981723.982.0FalseNoneNoneFalseNoneFalse3447.960
3327737116576NoneCSR 2023-24 It.No 13.5Fixing halogen/metal halide / SVL / IL / LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires. Each191.16191.161.0FalseNoneNoneFalseNoneFalse191.160
3327738116576NoneCSR 2023-24 It.No 5.42.2Fabricating supplying and mounting MS box made out .SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete 16SWG Sq CM0.510.5136000.0FalseNoneNoneFalseNoneFalse18360.00
3327739116576NoneCSR 2023-24 It.No 5.40.1Supplying .amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 100Amps 4x30x6mm Aluminum Strips Rmtr2908.72908.72.0FalseNoneNoneFalseNoneFalse5817.40
3327740116576NoneCSR 2023-24 It.No 5.41.1Supplying and fixing angle iron frame work iabricated out of M.S. angle iron. and M.S. flat . with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 40x40x6mm Rmtr359.9359.96.0FalseNoneNoneFalseNoneFalse2159.40
3327741116576NoneCSR 2023-24 It.No 5.15.1Supplying and fixing Moulded Case Circuit Breaker (MCCB) .over the existing wood/panel board using necessary screws, bolts, nuts and wiring complete. Protection of Overload and Short circuit with thermal Magnetic/Micro processor release and Earth Fault as per IS-13947. (lcu= lcs) FOUR POLE 100Amps 25kA Each7181.487181.481.0FalseNoneNoneFalseNoneFalse7181.480
3327742116576NoneCSR 2023-24 It.No 5.18.8Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 40Amps TPN Each3691.923691.922.0FalseNoneNoneFalseNoneFalse7383.840
3327743116576NoneCSR 2023-24 It.N0 5.18.4Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32Amps DP Each872.02872.026.0FalseNoneNoneFalseNoneFalse5232.120
3327744116576NoneCSR 2023-24 It.No 5.38 Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.C Each607.7607.72.0FalseNoneNoneFalseNoneFalse1215.40
3327745116576NoneCSR 2023-24 It.No 5.34 Supplying, fixing and wiring 50/5 to 400/5Amps 5VA burden Current Transformer. Class 0.5 accuracy with Tape Wound Each663.26663.263.0FalseNoneNoneFalseNoneFalse1989.780
3327746116576NoneCSR 2023-24 It.No 5.33Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH,KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy Each10991.710991.72.0FalseNoneNoneFalseNoneFalse21983.40
3327747116576NoneLUMPSUMElectrical Deposite for Power Sanction Lump Sum for Each35000.035000.01.0FalseNoneNoneFalseNoneFalse35000.00
17189630510000NoneNoneBuildings2 Construction of Health and Welness Center at Chandori in Aurad Taluk,Bidar District.((civil works-GF)4113889.86
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3327748116577NoneVol - III, P. no. 9, it. No. 2.5.ii.aClearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. Sq4.864.86750.0FalseNoneNoneFalseNoneFalse3645.00
3327749116577NoneVol - I, P. no. 8, It. No. 1.12Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. Cum117.71117.7175.0FalseNoneNoneFalseNoneFalse8828.250
3327750116577NoneVol - I, P. no. 8, It. No. 1.14Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work Cum126.38126.38221.3FalseNoneNoneFalseNoneFalse27967.8940
3327751116577NoneVol - I, P. no. 15, It. No. 2.1.3,Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. - Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates Cum7420.377420.3724.52FalseNoneNoneFalseNoneFalse181947.47240
3327752116577NoneVol - I, P. no. 15, It. No. 2.2.1Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/ trap/basalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) - M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Footings,Pedestal,Screed concrete over slab Cum7789.597789.5937.57FalseNoneNoneFalseNoneFalse292654.89630
3327753116577NoneVol - I, P. no. 7, It. No. 1.9Filling available excavated earth (excluding rock) in trenches, plinth,sides of foundations and other similar works etc. in layers not exceeding 0cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. Cum329.57329.57177.04FalseNoneNoneFalseNoneFalse58347.07280
3327754116577NoneVol - I, P. no. 7, It. No. 1.8Construction of Embankment by excavating the available approved Gravel/ Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. Cum587.29587.29198.61FalseNoneNoneFalseNoneFalse116641.66690
3327755116577NoneVol - II, P. no. 9, It. No. 5.1.1Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : Cement mortar 1:6 (1 cement : 6 coarse sand) Cum6952.036952.037.2FalseNoneNoneFalseNoneFalse50054.6160
3327756116577NoneVol - II, P. no. 9, It. No. 5.3Providing Coursed rubble masonry (second sort) with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) Cum7688.07688.05.4FalseNoneNoneFalseNoneFalse41515.20
3327757116577NoneVol - I, P. no. 16, It. No. 2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Cum8478.488478.4844.67FalseNoneNoneFalseNoneFalse378733.70160
3327758116577NoneVol - I, P. no. 111,Appendix I-Additionalities for Formwork, Centering & Scaffolding - Including cost of all materials, labours, HOM, I & UL, Curing with all lead and lifts etc. complete as per specifications and as directed by engineer-in-charge of the work. Footings Pedestal Cum623.17623.1729.44FalseNoneNoneFalseNoneFalse18346.12480
3327759116577NoneVol - I, P. no. 111,Appendix I-Additionalities for Formwork, Centering & Scaffolding - Including cost of all materials, labours, HOM, I & UL, Curing with all lead and lifts etc. complete as per specifications and as directed by engineer-in-charge of the work. COLUMNS Cum5934.935934.939.18FalseNoneNoneFalseNoneFalse54482.65740
3327760116577NoneVol - I, P. no. 111Appendix I-Additionalities for Formwork, Centering & Scaffolding - Including cost of all materials, labours, HOM, I & UL, Curing with all lead and lifts etc. complete as per specifications and as directed by engineer-in-charge of the work. PLINTH BEAM,Columns embedded in Plinth Beam Cum4239.244239.248.86FalseNoneNoneFalseNoneFalse37559.66640
3327761116577NoneVol - I, P. no. 111Appendix I-Additionalities for Formwork, Centering & Scaffolding - Including cost of all materials, labours, HOM, I & UL, Curing with all lead and lifts etc. complete as per specifications and as directed by engineer-in-charge of the work. LINTELS ROOF BEAM CONCRETE Cum5087.095087.0912.29FalseNoneNoneFalseNoneFalse62520.33610
3327762116577NoneVol - I, P. no. 111Appendix I-Additionalities for Formwork, Centering & Scaffolding - Including cost of all materials, labours, HOM, I & UL, Curing with all lead and lifts etc. complete as per specifications and as directed by engineer-in-charge of the work. ROOF SLAB Cum4239.244239.2414.08FalseNoneNoneFalseNoneFalse59688.49920
3327763116577NoneVol - I, P. no. 111Appendix I-Additionalities for Formwork, Centering & Scaffolding - Including cost of all materials, labours, HOM, I & UL, Curing with all lead and lifts etc. complete as per specifications and as directed by engineer-in-charge of the work. Chajja Cum3815.313815.311.03FalseNoneNoneFalseNoneFalse3929.76930
3327764116577NoneVol - I, P. no. 15, It. No. 2.1.6Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. - Mix 1:2:4 Using 20 mm nominal size graded crushed coarse aggregates Cill Concrete Cum7735.087735.081.69FalseNoneNoneFalseNoneFalse13072.28520
3327765116577NoneVol - 1, P. no.18, It. No. 2.11 aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.t110837.22110837.228.55FalseNoneNoneFalseNoneFalse947658.2310
3327766116577NoneVol - II, P. No. 14, It. No. 6.8Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. Ground Floor Wall - Upto Slab Beam Bottom Cum9873.599873.5937.38FalseNoneNoneFalseNoneFalse369074.79420
3327767116577NoneVol - II, P. No. 14, It. No. 6.13Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:4 (1 cement :4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. Sqm1209.261209.2635.55FalseNoneNoneFalseNoneFalse42989.1930
3327768116577NoneVol - II, P. No. 100, It. No. 12.13.1Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. Cum122431.79122431.790.45FalseNoneNoneFalseNoneFalse55094.30550
3327769116577NoneVol - II, P. No. 104, It. No. 12.51Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. Each1258.821258.824.0FalseNoneNoneFalseNoneFalse5035.280
3327770116577NoneVol - II, P. No. 219, It. No. 22.15.4Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge - SS Aldrop 16mm dia, 300mm Each464.63464.634.0FalseNoneNoneFalseNoneFalse1858.520
3327771116577NoneVol - II, P. No. 219, It. No. 22.15.1Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge - SS Handles 200mm Each557.55557.558.0FalseNoneNoneFalseNoneFalse4460.40
3327772116577NoneVol - II, P. No. 219, It. No. 22.15.6Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge - SS Tower Bolts 200x10mm Each185.85185.854.0FalseNoneNoneFalseNoneFalse743.40
3327773116577NoneVol - II, P. No. 219, It. No. 22.15.8Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge - SS hinges 125 mm Each61.9561.9516.0FalseNoneNoneFalseNoneFalse991.20
3327774116577NoneVol - II, P. No. 69, It. No. 10.6.2Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm Each68.1568.1512.0FalseNoneNoneFalseNoneFalse817.80
3327775116577NoneVol - II, P. No. 205, It. No. 20.79Supplying and fixing new teak wood beads wherever necessary including cost of materials, labour, complete as per specifications. Each64.4364.4324.0FalseNoneNoneFalseNoneFalse1546.320
3327776116577NoneVol - II, P. No. 105, It. No. 12.57.6Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 35 mm thick both side commercial Each4115.964115.9615.36FalseNoneNoneFalseNoneFalse63221.14560
3327777116577NoneVol - II, P. No. 110, It. No. 12.89Providing & fixing of 2.5 track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 94mm width x 45mm height with reinforcement of 1mm thickness and Sash with overall size of 39mm x 58mm with GI reinforcement of 1.5mm and mesh sash of size 25mm x 42mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 1819mm x 1819mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)Sqm8116.698116.699.84FalseNoneNoneFalseNoneFalse79868.22960
3327778116577NoneVol - II, P. No. 109, It. No. 12.85Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) Sqm7085.847085.840.72FalseNoneNoneFalseNoneFalse5101.80480
3327779116577NoneVol - II, P. No. 85, It. No. 11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding Kg208.15208.15206.64FalseNoneNoneFalseNoneFalse43012.1160
3327780116577NoneVol - II, P. No. 111, It. No. 12.93.1Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately) - Size 62 x 100mm Rmtr869.78869.789.8FalseNoneNoneFalseNoneFalse8523.8440
3327781116577NoneVol - II, P. No. 112, It. No. 12.94.1Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately) - 30 mm thickness Cum4317.924317.923.15FalseNoneNoneFalseNoneFalse13601.4480
3327782116577NoneVol - II, P. No. 42, It. No. 8.5.2Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sqm432.41432.41241.84FalseNoneNoneFalseNoneFalse104574.03440
3327783116577NoneVol - II, P. No. 43, It. No. 8.10Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sqm261.43261.4393.2FalseNoneNoneFalseNoneFalse24365.2760
3327784116577NoneVol - II, P. No. 50, It. No. 8.51Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. Sqm123.9123.9335.04FalseNoneNoneFalseNoneFalse41511.4560
3327785116577NoneVol - II, P. No. 42, It. No. 8.8Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (outside) Sqm459.67459.67163.75FalseNoneNoneFalseNoneFalse75270.96250
3327786116577NoneVol - II, P. No. 43, It. No. 8.16.1Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment Sqm42.1342.13676.2FalseNoneNoneFalseNoneFalse28488.3060
3327787116577NoneVol - II, P. No. 54, It. No. 8.79Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove. Rmtr64.4364.43271.01FalseNoneNoneFalseNoneFalse17461.17430
3327788116577NoneVol - II, P. No. 60, It. No. 9.12.2Providing and laying vitrified floor tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm Sqm1418.661418.6656.4FalseNoneNoneFalseNoneFalse80012.4240
3327789116577NoneVol - II, P. No. 40, It. No. 8.2.2Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sqm345.68345.6867.22FalseNoneNoneFalseNoneFalse23236.60960
3327790116577NoneVol - II, P. No. 60, It. No. 9.11Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thick- ness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. Sqm1101.471101.475.98FalseNoneNoneFalseNoneFalse6586.79060
3327791116577NoneVol - II, P. No. 64, It. No. 9.39Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. Sqm1795.311795.3167.22FalseNoneNoneFalseNoneFalse120680.73820
3327792116577NoneVol - II, P. No. 48, It. No. 8.39Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sqm157.35157.35335.04FalseNoneNoneFalseNoneFalse52718.5440
3327793116577NoneVol - II, P. No. 46, It. No. 8.31Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives with pure Acrylic Resin, UV resistant, dirt & pick up resistant, Alkali & Water resistant of required shade: New work (Two coats applied @ 1.43 L/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sqm220.54220.54163.75FalseNoneNoneFalseNoneFalse36113.4250
3327794116577NoneVol - II, P. No. 48, It. No. 8.40Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sqm142.49142.4962.22FalseNoneNoneFalseNoneFalse8865.72780
3327795116577NoneVol - II, P. No. 48, It. No. 8.38Painting with oil type wood preservative of approved brand and manufacture :New work (two coats) to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sqm49.5649.5625.2FalseNoneNoneFalseNoneFalse1248.9120
3327796116577NoneVol - II, P. No. 48, It. No. 9.24Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cat Eye, River Pink or equivalent.Sqm3533.633533.6351.69FalseNoneNoneFalseNoneFalse182653.33470
3327797116577NoneVol - II, P. No. 48, It. No. 9.24Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. Kg700.04700.04234.0FalseNoneNoneFalseNoneFalse163809.360
3327798116577NoneVol - II, P. No. 87, It. No. 11.35.1.1Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For Fixed Portion : Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) including cost of materials, labour, usage charges of machinery complete as per specifications. Kg560.03560.0388.2FalseNoneNoneFalseNoneFalse49394.6460
3327799116577NoneLUMPSUMThe Tenderer (agency) should arrange to obtain (get), detailed Architectural drawings and elevations, Structural designs and drawings including Soil exploration and providing consultancy for Architectural designs & drawings, elevation, 3D view, Internal and External Electrical services including electrical infrastructure , Lifts, CCTV/Net working system interior layout and liaison with other department and approval of pollution control board and allied works etc., and any other drawings related to this project (This item is included in schedule B as a item) and 6 sets of as built drawings should be submitted to the employer. The Consultancy Fees which is included as an item in schedule B shall be paid on prorate basis of the main work or by negotiation with the employer. - - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge Lump Sum for Each43365.043365.01.0FalseNoneNoneFalseNoneFalse43365.00
17189630510000NoneNoneBuildings2 Construction of Health and Welness Center at Chandori in Aurad Taluk,Bidar District.(Civil works - First Floor)1723935.87
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3327800116578NoneVol - I, P. no. 16, It. No. 2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Cum8559.228559.2220.89FalseNoneNoneFalseNoneFalse178802.10580
3327801116578NoneVol - I, P. no. 111Appendix I-Additionalities for Formwork, Centering & Scaffolding - Including cost of all materials, labours, HOM, I & UL, Curing with all lead and lifts etc. complete as per specifications and as directed by engineer-in-charge of the work FIRST FLOOR COLUMNS PARAPET COLUMNS Cum5991.465991.463.47FalseNoneNoneFalseNoneFalse20790.36620
3327802116578NoneVol - I, P. no. 111Appendix I-Additionalities for Formwork, Centering & Scaffolding - Including cost of all materials, labours, HOM, I & UL, Curing with all lead and lifts etc. complete as per specifications and as directed by engineer-in-charge of the work. Lintel Concrete FIRST FLOOR ROOF BEAM CONCRETE Cum5135.535135.535.85FalseNoneNoneFalseNoneFalse30042.85050
3327803116578NoneVol - I, P. no. 111,Appendix I-Additionalities for Formwork, Centering & Scaffolding - Including cost of all materials, labours, HOM, I & UL, Curing with all lead and lifts etc. complete as per specifications and as directed by engineer-in-charge of the work. ROOF SLAB Cum4279.614279.6118.49FalseNoneNoneFalseNoneFalse79129.98890
3327804116578NoneVol - I, P. no. 111Appendix I-Additionalities for Formwork, Centering & Scaffolding - Including cost of all materials, labours, HOM, I & UL, Curing with all lead and lifts etc. complete as per specifications and as directed by engineer-in-charge of the work. Chajja Cum3851.653851.650.26FalseNoneNoneFalseNoneFalse1001.4290
3327805116578NoneVol - I, P. no. 15, It. No. 2.1.6Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. - Mix 1:2:4 Using 20 mm nominal size graded crushed coarse aggregates Cum7808.747808.741.69FalseNoneNoneFalseNoneFalse13196.77060
3327806116578NoneVol - 1, P. no.18, It. No. 2.11 aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.t111892.82111892.822.56FalseNoneNoneFalseNoneFalse286445.61920
3327807116578NoneVol - II, P. No. 14, It. No. 6.8Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. Cum9967.639967.6322.8FalseNoneNoneFalseNoneFalse227261.9640
3327808116578NoneVol - II, P. No. 14, It. No. 6.13Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:4 (1 cement :4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. Sqm1220.781220.7845.11FalseNoneNoneFalseNoneFalse55069.38580
3327809116578NoneVol - II, P. No. 100, It. No. 12.13.1Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. Cum123597.8123597.80.45FalseNoneNoneFalseNoneFalse55619.010
3327810116578NoneVol - II, P. No. 104, It. No. 12.51Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. Each1270.811270.814.0FalseNoneNoneFalseNoneFalse5083.240
3327811116578NoneVol - II, P. No. 219, It. No. 22.15.4Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge - SS Aldrop 16mm dia, 300mm Each469.05469.054.0FalseNoneNoneFalseNoneFalse1876.20
3327812116578NoneVol - II, P. No. 219, It. No. 22.15.1Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge - SS Handles 200mm Each562.86562.868.0FalseNoneNoneFalseNoneFalse4502.880
3327813116578NoneVol - II, P. No. 219, It. No. 22.15.6Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge - SS Tower Bolts 200x10mm Each187.62187.624.0FalseNoneNoneFalseNoneFalse750.480
3327814116578NoneVol - II, P. No. 219, It. No. 22.15.8Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge - SS hinges 125 mm Each62.5462.5416.0FalseNoneNoneFalseNoneFalse1000.640
3327815116578NoneVol - II, P. No. 69, It. No. 10.6.2Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm Each68.7968.7912.0FalseNoneNoneFalseNoneFalse825.480
3327816116578NoneVol - II, P. No. 205, It. No. 20.79Supplying and fixing new teak wood beads wherever necessary including cost of materials, labour, complete as per specifications. No65.0465.0424.0FalseNoneNoneFalseNoneFalse1560.960
3327817116578NoneVol - II, P. No. 105, It. No. 12.57.6Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 35 mm thick both side commercial Sqm4155.164155.1615.36FalseNoneNoneFalseNoneFalse63823.25760
3327818116578NoneVol - II, P. No. 110, It. No. 12.89Providing & fixing of 2.5 track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 94mm width x 45mm height with reinforcement of 1mm thickness and Sash with overall size of 39mm x 58mm with GI reinforcement of 1.5mm and mesh sash of size 25mm x 42mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 1819mm x 1819mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) Sqm8193.998193.999.6FalseNoneNoneFalseNoneFalse78662.3040
3327819116578NoneVol - II, P. No. 109, It. No. 12.85Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) Sqm7153.337153.330.72FalseNoneNoneFalseNoneFalse5150.39760
3327820116578NoneVol - II, P. No. 85, It. No. 11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding Kg210.13210.13206.64FalseNoneNoneFalseNoneFalse43421.26320
3327821116578NoneVol - II, P. No. 111, It. No. 12.93.1Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately) - Size 62 x 100mm Rmtr878.06878.069.8FalseNoneNoneFalseNoneFalse8604.9880
3327822116578NoneVol - II, P. No. 112, It. No. 12.94.1Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately) - 30 mm thickness Cum4359.044359.043.15FalseNoneNoneFalseNoneFalse13730.9760
3327823116578NoneVol - II, P. No. 42, It. No. 8.5.2Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sqm436.53436.53141.19FalseNoneNoneFalseNoneFalse61633.67070
3327824116578NoneVol - II, P. No. 43, It. No. 8.10Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sqm263.92263.9272.81FalseNoneNoneFalseNoneFalse19216.01520
3327825116578Noneol - II, P. No. 50, It. No. 8.51Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. Sqm125.08125.08214.0FalseNoneNoneFalseNoneFalse26767.120
3327826116578NoneVol - II, P. No. 42, It. No. 8.8Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (outside) Sqm464.05464.05146.23FalseNoneNoneFalseNoneFalse67858.03150
3327827116578NoneVol - II, P. No. 43, It. No. 8.16.1Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment Sqm42.5342.53676.2FalseNoneNoneFalseNoneFalse28758.7860
3327828116578NoneVol - II, P. No. 54, It. No. 8.79Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove. Rmtr65.0465.04271.01FalseNoneNoneFalseNoneFalse17626.49040
3327829116578NoneVol - II, P. No. 60, It. No. 9.12.2Providing and laying vitrified floor tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm Sqm1432.171432.1752.46FalseNoneNoneFalseNoneFalse75131.63820
3327830116578NoneVol - II, P. No. 40, It. No. 8.2.2Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sqm348.97348.9767.22FalseNoneNoneFalseNoneFalse23457.76340
3327831116578NoneVol - II, P. No. 60, It. No. 9.11Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thick- ness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. Sqm1111.961111.965.98FalseNoneNoneFalseNoneFalse6649.52080
3327832116578NoneVol - II, P. No. 64, It. No. 9.39Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. Sqm1812.411812.416.3FalseNoneNoneFalseNoneFalse11418.1830
3327833116578NoneVol - II, P. No. 48, It. No. 8.39Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sqm158.85158.85214.0FalseNoneNoneFalseNoneFalse33993.90
3327834116578NoneVol - II, P. No. 46, It. No. 8.31Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives with pure Acrylic Resin, UV resistant, dirt & pick up resistant, Alkali & Water resistant of required shade: New work (Two coats applied @ 1.43 L/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sqm222.64222.64146.23FalseNoneNoneFalseNoneFalse32556.64720
3327835116578NoneVol - II, P. No. 48, It. No. 8.40Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sqm143.84143.8462.22FalseNoneNoneFalseNoneFalse8949.72480
3327836116578NoneVol - II, P. No. 48, It. No. 8.38Painting with oil type wood preservative of approved brand and manufacture :New work (two coats) to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sqm50.0350.0325.2FalseNoneNoneFalseNoneFalse1260.7560
3327837116578NoneVol - II, P. No. 48, It. No. 9.24Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cat Eye, River Pink or equivalent. Sqm3567.283567.2813.5FalseNoneNoneFalseNoneFalse48158.280
3327838116578NoneVol - II, P. No. 48, It. No. 9.24Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. Kg706.7706.7119.07FalseNoneNoneFalseNoneFalse84146.7690
17189630510000NoneNoneBuildings2 Construction of Health and Welness Center at Chandori in Aurad Taluk,Bidar District.(nternal water supply & sanitary works)196185.86
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3327839116579NoneV-II, P. No. 28, It. No. 14.28.2.2Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. 40mm dia pipes, From wash basin waste lines Rmtr113.99113.994.0FalseNoneNoneFalseNoneFalse455.960
3327840116579NoneVol - V, P. no. 120, It. No. 10.14.9Providing and installing at site of work P.V.C. pipes including cost of pipes and specials and labour, including lowering into trenches, laying true to line, level and perfect linking at joints leak proof including jointing of approved type with all labour charges and all lift charges, handling charges including encasing the pipe around to a depth not less than 15 cms with gravel or selected earth available from the excavation etc. complete. PVC pipe - 75mm(weight of pipe -0.917 kg) Rmtr237.89237.8920.0FalseNoneNoneFalseNoneFalse4757.80
3327841116579NoneVol - V, P. no. 120, It. No. 10.14.11PVC pipe - OD 110mm and 6 Kg/sqcm, sanitary lines Rmtr443.56443.5650.0FalseNoneNoneFalseNoneFalse22178.00
3327842116579NoneVol - II, P. no. 136, It. No. 14.31Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. No1511.581511.584.0FalseNoneNoneFalseNoneFalse6046.320
3327843116579NoneVol - II, P. no. 123, It. No. 14.3.1Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid Each7405.57405.54.0FalseNoneNoneFalseNoneFalse29622.00
3327844116579NoneVol - II, P. no. 117, It. No. 13.3.1Providing and fixing brass stop cock of approved quality : 15 mm nominal bore Each370.46370.464.0FalseNoneNoneFalseNoneFalse1481.840
3327845116579NoneVol - II, P. no. 132, It. No. 14.7.1Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15mm C.P. brass pillar taps Each3818.63818.64.0FalseNoneNoneFalseNoneFalse15274.40
3327846116579NoneVol - II, P. No. 122, it. No. 13.32.2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. Rmtr469.58469.5860.0FalseNoneNoneFalseNoneFalse28174.80
3327847116579NoneVol - II, P. No. 122, It. No. 13.33.2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) External & Shafts & Terrace 20 mm nominal dia Pipes Rmtr268.86268.8620.0FalseNoneNoneFalseNoneFalse5377.20
3327848116579NoneVol - II, P. No. 122, It. No. 13.33.3Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) External & Shafts & Terrace 25 mm nominal dia Pipes Rmtr366.74366.7450.0FalseNoneNoneFalseNoneFalse18337.00
3327849116579NoneVol - V, P. No. 191, It. No. 16.9Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.(CATCH BASIN) No6757.516757.516.0FalseNoneNoneFalseNoneFalse40545.060
3327850116579NoneVol - II, P. no. 123, It. No. 13.34Providing and placing on terrace (at all floor levels) polyethylene water storage tank,IS:12701 marked,with cover and suitable locking arrangement and making necessary holes for inlet,outlet and overflow pipes but without fittings and the base support for tank. Ltr11.1511.152000.0FalseNoneNoneFalseNoneFalse22300.00
3327851116579NoneVol - II, P. no. 127, It. No. 13.59Providing and fixing PVC (S.W.R) Nahani Trap 10cms x 10cms with all fitting arrangements & all necessary accessories complete Ground Toilet 10Cms X 7.5Cms No272.58272.586.0FalseNoneNoneFalseNoneFalse1635.480
17189630510000NoneNoneBuildings2 Construction of Health and Welness Center at Chandori in Aurad Taluk,Bidar District.(Internal Electrification)438163.01
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3327852116580NoneCSR 2023-24 It.No 2.02.01Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point up to 3Mtr from tapping point to out let via switch Pack317.42317.4220.0FalseNoneNoneFalseNoneFalse6348.40
3327853116580NoneCSR 2023-24 It.No 2.2.2Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Medium point above 3mtr up to 6Mtr from tapping point to out let via switch Pack447.22447.2215.0FalseNoneNoneFalseNoneFalse6708.30
3327854116580NoneCSR 2023-24 It.No 2.2.3Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Above 6Mtr up to 10Mtr from tapping Point to out let via switch Pack654.9654.910.0FalseNoneNoneFalseNoneFalse6549.00
3327855116580NoneCSR 2023-24 It.No 3.4.2Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall Each187.62187.624.0FalseNoneNoneFalseNoneFalse750.480
3327856116580NoneCSR 2023-24 It.No 3.4.3Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 4-5Way Each208.86208.862.0FalseNoneNoneFalseNoneFalse417.720
3327857116580NoneCSR 2023-24 It.No 3.4.4Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 6Way Each259.6259.610.0FalseNoneNoneFalseNoneFalse2596.00
3327858116580NoneCSR 2023-24 It.No 3.4.5Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 8Way Each307.98307.985.0FalseNoneNoneFalseNoneFalse1539.90
3327859116580NoneCSR 2023-24 It.No 3.4.6Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 10-12Way Each376.42376.4210.0FalseNoneNoneFalseNoneFalse3764.20
3327860116580NoneCSR 2023-24 It.No 3.5.2Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 3 Module Each189.98189.984.0FalseNoneNoneFalseNoneFalse759.920
3327861116580NoneCSR 2023-24 It.No 3.5.3Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 4 Module Each276.12276.1210.0FalseNoneNoneFalseNoneFalse2761.20
3327862116580NoneCSR 2023-24, It.No 3.5.5Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 8 Module Each335.12335.125.0FalseNoneNoneFalseNoneFalse1675.60
3327863116580NoneCSR 2023-24 It.No 3.5.6Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 10-12 Module Each405.92405.9210.0FalseNoneNoneFalseNoneFalse4059.20
3327864116580NoneCSR 2023-24 It.No 3.6.1Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps one way. Each120.36120.36120.0FalseNoneNoneFalseNoneFalse14443.20
3327865116580NoneCSR 2023-24 It.No 3.6.3Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps 3way socket. Each201.78201.7820.0FalseNoneNoneFalseNoneFalse4035.60
3327866116580NoneCSR 2023-24, It.No 3.6.4Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Stepped Fan Regulator. Each421.26421.2610.0FalseNoneNoneFalseNoneFalse4212.60
3327867116580NoneCSR 2023-24, It.No 3.6.8Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 16Amps one way switch Each212.4212.420.0FalseNoneNoneFalseNoneFalse4248.00
3327868116580NoneCSR 2023-24 It.No 3.6.10Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 32Amps DP switch Each384.68384.684.0FalseNoneNoneFalseNoneFalse1538.720
3327869116580NoneCSR 2023-24 It.no 3.6.11Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6/16Amps universal socket Each278.48278.4810.0FalseNoneNoneFalseNoneFalse2784.80
3327870116580NoneCSR 2023-24 It.No 3.6.12Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. TV/Telephone socket Each184.08184.082.0FalseNoneNoneFalseNoneFalse368.160
3327871116580NoneCSR 2023-24 It.No 1.13Supplyin and Fixing Metal Fan Box with Round Hook. No138.06138.0610.0FalseNoneNoneFalseNoneFalse1380.60
3327872116580NoneCSR 2023-24 P.No 1.2.1Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 19/20mm dia 2mm thick Rmtr77.8877.8890.0FalseNoneNoneFalseNoneFalse7009.20
3327873116580NoneCSR 2023-24 It.No 1.2.2Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 25mm dia 2mm thick Rmtr92.0492.04150.0FalseNoneNoneFalseNoneFalse13806.00
3327874116580NoneCSR 2023-24 It.No 1.2.3Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 32mm dia 2mm thick Rmtr121.54121.5430.0FalseNoneNoneFalseNoneFalse3646.20
3327875116580NoneCSR 2023-24 It.No 1.7.1Extra for Groove cutting in brick wall/CC floor to the suitable depth for concealing of Conduit/GI pipe and plastering, finishing upto wall surface completeRmtr34.2234.2260.0FalseNoneNoneFalseNoneFalse2053.20
3327876116580NoneCSR 2023-24 It.No 2.3.2Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5 sqmm Rmtr30.6830.68180.0FalseNoneNoneFalseNoneFalse5522.40
3327877116580NoneCSR 2023-24 It.No 2.3.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.5 sqmm Rmtr49.5649.561080.0FalseNoneNoneFalseNoneFalse53524.80
3327878116580NoneCSR 2023-24 It.No 2.3.4Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 4 sqmm Rmtr74.3474.34360.0FalseNoneNoneFalseNoneFalse26762.40
3327879116580NoneCSR 2023-24 It.No 5.19.4Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure( Double Door) 12 Way SP & NEach2198.342198.342.0FalseNoneNoneFalseNoneFalse4396.680
3327880116580NoneCSR 2023-24 It.No 5.18.1Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32 A SPEach489.7489.720.0FalseNoneNoneFalseNoneFalse9794.00
3327881116580NoneCSR 2023-24 It.No 5.18.4Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898" 6-32 A DP Each872.02872.022.0FalseNoneNoneFalseNoneFalse1744.040
3327882116580None19-20SR P.No 6.4.4Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975 4 core 16 sqmm Km167373.56167373.560.25FalseNoneNoneFalseNoneFalse41843.390
3327883116580NoneCSR 2023-24 P.No 11.3.2Supplying of .feet - PVC Batten with integrated LED tube .W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. Each814.2814.220.0FalseNoneNoneFalseNoneFalse16284.00
3327884116580NoneCSR 2023-24 It.No 11.4.1Supplying & fixing of retrofit type - LED bulb.W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70%. efficacy 80 lumen per watt, life25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 5-6 W,Each949.9949.96.0FalseNoneNoneFalseNoneFalse5699.40
3327885116580NoneCSR 2023-24 It.No 6.1Supplying exhaust fan of 1440 RPM of 300mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply. Each1760.561760.566.0FalseNoneNoneFalseNoneFalse10563.360
3327886116580NoneCSR 2023-24 It.No 6.3.1Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system. 48" Sweep (1200mm) Regular model Each3521.123521.1210.0FalseNoneNoneFalseNoneFalse35211.20
3327887116580NoneCSR 2023-24 P.No 13.7.1Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall / ceiling / Rafter / Girders Each143.96143.9620.0FalseNoneNoneFalseNoneFalse2879.20
3327888116580NoneCSR 2023-24 It.No13.10Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S' hook with fan regulator to the existing board together with supplying and fixing 5 amps. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring. Each201.78201.7810.0FalseNoneNoneFalseNoneFalse2017.80
3327889116580NoneCSR 2023-34 13.13Fixing one exhaust fan after making a suitable nitch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 amps, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame. Each834.26834.266.0FalseNoneNoneFalseNoneFalse5005.560
3327890116580NoneCSR 2023-34 It.No 11.8.2Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with .W System Power consumption. LED Efficiency130lm/w, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Streetlight 40watts No4748.324748.322.0FalseNoneNoneFalseNoneFalse9496.640
3327891116580NoneCSR 2023-24 IT.No 13.4.1Supplying and fixing telescopic M.S. bracket fabricated by using 0.5m length 4” dia telescopic M. S. pipe, with 2” dia 1.5m long M. S. bracket and are welded with suitable angle, using 6mm thick M. S. sheet, grip bolts & nuts, as required, suitable for 9 to 12 Mtrs. M. S. tubular pole, with necessary two coats of painting, with all other accessories. Single bracket 1.5 Mtr. Length Each1723.981723.982.0FalseNoneNoneFalseNoneFalse3447.960
3327892116580NoneCSR 2023-24 It.No 13.5Fixing halogen/metal halide / SVL / IL / LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires. Each191.16191.161.0FalseNoneNoneFalseNoneFalse191.160
3327893116580NoneCSR 2023-24 It.No 5.42.2Fabricating supplying and mounting MS box made out .SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete 16SWG Sq CM0.510.5136000.0FalseNoneNoneFalseNoneFalse18360.00
3327894116580NoneCSR 2023-24 It.No 5.40.1Supplying .amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 100Amps 4x30x6mm Aluminum Strips Rmtr2908.72908.72.0FalseNoneNoneFalseNoneFalse5817.40
3327895116580NoneCSR 2023-24 It.No 5.41.1Supplying and fixing angle iron frame work iabricated out of M.S. angle iron. and M.S. flat . with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 40x40x6mm Rmtr359.9359.96.0FalseNoneNoneFalseNoneFalse2159.40
3327896116580NoneCSR 2023-24 It.No 5.15.1Supplying and fixing Moulded Case Circuit Breaker (MCCB) .over the existing wood/panel board using necessary screws, bolts, nuts and wiring complete. Protection of Overload and Short circuit with thermal Magnetic/Micro processor release and Earth Fault as per IS-13947. (lcu= lcs) FOUR POLE 100Amps 25kA Each7181.487181.481.0FalseNoneNoneFalseNoneFalse7181.480
3327897116580NoneCSR 2023-24 It.No 5.18.8Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 40Amps TPN Each3691.923691.922.0FalseNoneNoneFalseNoneFalse7383.840
3327898116580NoneCSR 2023-24 It.N0 5.18.4Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32Amps DP Each872.02872.026.0FalseNoneNoneFalseNoneFalse5232.120
3327899116580NoneCSR 2023-24 It.No 5.38 Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.C Each607.7607.72.0FalseNoneNoneFalseNoneFalse1215.40
3327900116580NoneCSR 2023-24 It.No 5.34 Supplying, fixing and wiring 50/5 to 400/5Amps 5VA burden Current Transformer. Class 0.5 accuracy with Tape Wound Each663.26663.263.0FalseNoneNoneFalseNoneFalse1989.780
3327901116580NoneCSR 2023-24 It.No 5.33Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH,KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy Each10991.710991.72.0FalseNoneNoneFalseNoneFalse21983.40
3327902116580NoneLUMPSUMElectrical Deposite for Power Sanction Lump Sum for Each35000.035000.01.0FalseNoneNoneFalseNoneFalse35000.00
17189630510000NoneNoneBuildings3 Construction of Health and Welness Center at Madnoor in Aurad Taluk,Bidar District(Civil works - Ground Floor)4113889.86
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3327903116581NoneVol - III, P. no. 9, it. No. 2.5.ii.aClearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. Sq4.864.86750.0FalseNoneNoneFalseNoneFalse3645.00
3327904116581NoneVol - I, P. no. 8, It. No. 1.12Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. Cum117.71117.7175.0FalseNoneNoneFalseNoneFalse8828.250
3327905116581NoneVol - I, P. no. 8, It. No. 1.14Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work Cum126.38126.38221.3FalseNoneNoneFalseNoneFalse27967.8940
3327906116581NoneVol - I, P. no. 15, It. No. 2.1.3,Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. - Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates Cum7420.377420.3724.52FalseNoneNoneFalseNoneFalse181947.47240
3327907116581NoneVol - I, P. no. 15, It. No. 2.2.1Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/ trap/basalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) - M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Footings,Pedestal,Screed concrete over slab Cum7789.597789.5937.57FalseNoneNoneFalseNoneFalse292654.89630
3327908116581NoneVol - I, P. no. 7, It. No. 1.9Filling available excavated earth (excluding rock) in trenches, plinth,sides of foundations and other similar works etc. in layers not exceeding 0cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. Cum329.57329.57177.04FalseNoneNoneFalseNoneFalse58347.07280
3327909116581NoneVol - I, P. no. 7, It. No. 1.8Construction of Embankment by excavating the available approved Gravel/ Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. Cum587.29587.29198.61FalseNoneNoneFalseNoneFalse116641.66690
3327910116581NoneVol - II, P. no. 9, It. No. 5.1.1Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : Cement mortar 1:6 (1 cement : 6 coarse sand) Cum6952.036952.037.2FalseNoneNoneFalseNoneFalse50054.6160
3327911116581NoneVol - II, P. no. 9, It. No. 5.3Providing Coursed rubble masonry (second sort) with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) Cum7688.07688.05.4FalseNoneNoneFalseNoneFalse41515.20
3327912116581NoneVol - I, P. no. 16, It. No. 2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Cum8478.488478.4844.67FalseNoneNoneFalseNoneFalse378733.70160
3327913116581NoneVol - I, P. no. 111,Appendix I-Additionalities for Formwork, Centering & Scaffolding - Including cost of all materials, labours, HOM, I & UL, Curing with all lead and lifts etc. complete as per specifications and as directed by engineer-in-charge of the work. Footings Pedestal Cum623.17623.1729.44FalseNoneNoneFalseNoneFalse18346.12480
3327914116581NoneVol - I, P. no. 111,Appendix I-Additionalities for Formwork, Centering & Scaffolding - Including cost of all materials, labours, HOM, I & UL, Curing with all lead and lifts etc. complete as per specifications and as directed by engineer-in-charge of the work. COLUMNS Cum5934.935934.939.18FalseNoneNoneFalseNoneFalse54482.65740
3327915116581NoneVol - I, P. no. 111Appendix I-Additionalities for Formwork, Centering & Scaffolding - Including cost of all materials, labours, HOM, I & UL, Curing with all lead and lifts etc. complete as per specifications and as directed by engineer-in-charge of the work. PLINTH BEAM,Columns embedded in Plinth Beam Cum4239.244239.248.86FalseNoneNoneFalseNoneFalse37559.66640
3327916116581NoneVol - I, P. no. 111Appendix I-Additionalities for Formwork, Centering & Scaffolding - Including cost of all materials, labours, HOM, I & UL, Curing with all lead and lifts etc. complete as per specifications and as directed by engineer-in-charge of the work. LINTELS ROOF BEAM CONCRETE Cum5087.095087.0912.29FalseNoneNoneFalseNoneFalse62520.33610
3327917116581NoneVol - I, P. no. 111Appendix I-Additionalities for Formwork, Centering & Scaffolding - Including cost of all materials, labours, HOM, I & UL, Curing with all lead and lifts etc. complete as per specifications and as directed by engineer-in-charge of the work. ROOF SLAB Cum4239.244239.2414.08FalseNoneNoneFalseNoneFalse59688.49920
3327918116581NoneVol - I, P. no. 111Appendix I-Additionalities for Formwork, Centering & Scaffolding - Including cost of all materials, labours, HOM, I & UL, Curing with all lead and lifts etc. complete as per specifications and as directed by engineer-in-charge of the work. Chajja Cum3815.313815.311.03FalseNoneNoneFalseNoneFalse3929.76930
3327919116581NoneVol - I, P. no. 15, It. No. 2.1.6Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. - Mix 1:2:4 Using 20 mm nominal size graded crushed coarse aggregates Cill Concrete Cum7735.087735.081.69FalseNoneNoneFalseNoneFalse13072.28520
3327920116581NoneVol - 1, P. no.18, It. No. 2.11 aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.t110837.22110837.228.55FalseNoneNoneFalseNoneFalse947658.2310
3327921116581NoneVol - II, P. No. 14, It. No. 6.8Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. Ground Floor Wall - Upto Slab Beam Bottom Cum9873.599873.5937.38FalseNoneNoneFalseNoneFalse369074.79420
3327922116581NoneVol - II, P. No. 14, It. No. 6.13Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:4 (1 cement :4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. Sqm1209.261209.2635.55FalseNoneNoneFalseNoneFalse42989.1930
3327923116581NoneVol - II, P. No. 100, It. No. 12.13.1Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. Cum122431.79122431.790.45FalseNoneNoneFalseNoneFalse55094.30550
3327924116581NoneVol - II, P. No. 104, It. No. 12.51Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. Each1258.821258.824.0FalseNoneNoneFalseNoneFalse5035.280
3327925116581NoneVol - II, P. No. 219, It. No. 22.15.4Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge - SS Aldrop 16mm dia, 300mm Each464.63464.634.0FalseNoneNoneFalseNoneFalse1858.520
3327926116581NoneVol - II, P. No. 219, It. No. 22.15.1Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge - SS Handles 200mm Each557.55557.558.0FalseNoneNoneFalseNoneFalse4460.40
3327927116581NoneVol - II, P. No. 219, It. No. 22.15.6Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge - SS Tower Bolts 200x10mm Each185.85185.854.0FalseNoneNoneFalseNoneFalse743.40
3327928116581NoneVol - II, P. No. 219, It. No. 22.15.8Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge - SS hinges 125 mm Each61.9561.9516.0FalseNoneNoneFalseNoneFalse991.20
3327929116581NoneVol - II, P. No. 69, It. No. 10.6.2Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm Each68.1568.1512.0FalseNoneNoneFalseNoneFalse817.80
3327930116581NoneVol - II, P. No. 205, It. No. 20.79Supplying and fixing new teak wood beads wherever necessary including cost of materials, labour, complete as per specifications. Each64.4364.4324.0FalseNoneNoneFalseNoneFalse1546.320
3327931116581NoneVol - II, P. No. 105, It. No. 12.57.6Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 35 mm thick both side commercial Each4115.964115.9615.36FalseNoneNoneFalseNoneFalse63221.14560
3327932116581NoneVol - II, P. No. 110, It. No. 12.89Providing & fixing of 2.5 track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 94mm width x 45mm height with reinforcement of 1mm thickness and Sash with overall size of 39mm x 58mm with GI reinforcement of 1.5mm and mesh sash of size 25mm x 42mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 1819mm x 1819mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)Sqm8116.698116.699.84FalseNoneNoneFalseNoneFalse79868.22960
3327933116581NoneVol - II, P. No. 109, It. No. 12.85Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) Sqm7085.847085.840.72FalseNoneNoneFalseNoneFalse5101.80480
3327934116581NoneVol - II, P. No. 85, It. No. 11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding Kg208.15208.15206.64FalseNoneNoneFalseNoneFalse43012.1160
3327935116581NoneVol - II, P. No. 111, It. No. 12.93.1Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately) - Size 62 x 100mm Rmtr869.78869.789.8FalseNoneNoneFalseNoneFalse8523.8440
3327936116581NoneVol - II, P. No. 112, It. No. 12.94.1Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately) - 30 mm thickness Cum4317.924317.923.15FalseNoneNoneFalseNoneFalse13601.4480
3327937116581NoneVol - II, P. No. 42, It. No. 8.5.2Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sqm432.41432.41241.84FalseNoneNoneFalseNoneFalse104574.03440
3327938116581NoneVol - II, P. No. 43, It. No. 8.10Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sqm261.43261.4393.2FalseNoneNoneFalseNoneFalse24365.2760
3327939116581NoneVol - II, P. No. 50, It. No. 8.51Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. Sqm123.9123.9335.04FalseNoneNoneFalseNoneFalse41511.4560
3327940116581NoneVol - II, P. No. 42, It. No. 8.8Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (outside) Sqm459.67459.67163.75FalseNoneNoneFalseNoneFalse75270.96250
3327941116581NoneVol - II, P. No. 43, It. No. 8.16.1Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment Sqm42.1342.13676.2FalseNoneNoneFalseNoneFalse28488.3060
3327942116581NoneVol - II, P. No. 54, It. No. 8.79Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove. Rmtr64.4364.43271.01FalseNoneNoneFalseNoneFalse17461.17430
3327943116581NoneVol - II, P. No. 60, It. No. 9.12.2Providing and laying vitrified floor tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm Sqm1418.661418.6656.4FalseNoneNoneFalseNoneFalse80012.4240
3327944116581NoneVol - II, P. No. 40, It. No. 8.2.2Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sqm345.68345.6867.22FalseNoneNoneFalseNoneFalse23236.60960
3327945116581NoneVol - II, P. No. 60, It. No. 9.11Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thick- ness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. Sqm1101.471101.475.98FalseNoneNoneFalseNoneFalse6586.79060
3327946116581NoneVol - II, P. No. 64, It. No. 9.39Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. Sqm1795.311795.3167.22FalseNoneNoneFalseNoneFalse120680.73820
3327947116581NoneVol - II, P. No. 48, It. No. 8.39Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sqm157.35157.35335.04FalseNoneNoneFalseNoneFalse52718.5440
3327948116581NoneVol - II, P. No. 46, It. No. 8.31Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives with pure Acrylic Resin, UV resistant, dirt & pick up resistant, Alkali & Water resistant of required shade: New work (Two coats applied @ 1.43 L/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sqm220.54220.54163.75FalseNoneNoneFalseNoneFalse36113.4250
3327949116581NoneVol - II, P. No. 48, It. No. 8.40Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sqm142.49142.4962.22FalseNoneNoneFalseNoneFalse8865.72780
3327950116581NoneVol - II, P. No. 48, It. No. 8.38Painting with oil type wood preservative of approved brand and manufacture :New work (two coats) to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sqm49.5649.5625.2FalseNoneNoneFalseNoneFalse1248.9120
3327951116581NoneVol - II, P. No. 48, It. No. 9.24Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cat Eye, River Pink or equivalent.Sqm3533.633533.6351.69FalseNoneNoneFalseNoneFalse182653.33470
3327952116581NoneVol - II, P. No. 48, It. No. 9.24Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. Kg700.04700.04234.0FalseNoneNoneFalseNoneFalse163809.360
3327953116581NoneVol - II, P. No. 87, It. No. 11.35.1.1Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For Fixed Portion : Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) including cost of materials, labour, usage charges of machinery complete as per specifications. Kg560.03560.0388.2FalseNoneNoneFalseNoneFalse49394.6460
3327954116581NoneLUMPSUMThe Tenderer (agency) should arrange to obtain (get), detailed Architectural drawings and elevations, Structural designs and drawings including Soil exploration and providing consultancy for Architectural designs & drawings, elevation, 3D view, Internal and External Electrical services including electrical infrastructure , Lifts, CCTV/Net working system interior layout and liaison with other department and approval of pollution control board and allied works etc., and any other drawings related to this project (This item is included in schedule B as a item) and 6 sets of as built drawings should be submitted to the employer. The Consultancy Fees which is included as an item in schedule B shall be paid on prorate basis of the main work or by negotiation with the employer. - - - - etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge Lump Sum for Each43365.043365.01.0FalseNoneNoneFalseNoneFalse43365.00
17189630510000NoneNoneBuildings3 Construction of Health and Welness Center at Madnoor in Aurad Taluk,Bidar District(Civil works - First Floor)1723935.87
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3327955116582NoneVol - I, P. no. 16, It. No. 2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Cum8559.228559.2220.89FalseNoneNoneFalseNoneFalse178802.10580
3327956116582NoneVol - I, P. no. 111Appendix I-Additionalities for Formwork, Centering & Scaffolding - Including cost of all materials, labours, HOM, I & UL, Curing with all lead and lifts etc. complete as per specifications and as directed by engineer-in-charge of the work FIRST FLOOR COLUMNS PARAPET COLUMNS Cum5991.465991.463.47FalseNoneNoneFalseNoneFalse20790.36620
3327957116582NoneVol - I, P. no. 111Appendix I-Additionalities for Formwork, Centering & Scaffolding - Including cost of all materials, labours, HOM, I & UL, Curing with all lead and lifts etc. complete as per specifications and as directed by engineer-in-charge of the work. Lintel Concrete FIRST FLOOR ROOF BEAM CONCRETE Cum5135.535135.535.85FalseNoneNoneFalseNoneFalse30042.85050
3327958116582NoneVol - I, P. no. 111,Appendix I-Additionalities for Formwork, Centering & Scaffolding - Including cost of all materials, labours, HOM, I & UL, Curing with all lead and lifts etc. complete as per specifications and as directed by engineer-in-charge of the work. ROOF SLAB Cum4279.614279.6118.49FalseNoneNoneFalseNoneFalse79129.98890
3327959116582NoneVol - I, P. no. 111Appendix I-Additionalities for Formwork, Centering & Scaffolding - Including cost of all materials, labours, HOM, I & UL, Curing with all lead and lifts etc. complete as per specifications and as directed by engineer-in-charge of the work. Chajja Cum3851.653851.650.26FalseNoneNoneFalseNoneFalse1001.4290
3327960116582NoneVol - I, P. no. 15, It. No. 2.1.6Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. - Mix 1:2:4 Using 20 mm nominal size graded crushed coarse aggregates Cum7808.747808.741.69FalseNoneNoneFalseNoneFalse13196.77060
3327961116582NoneVol - 1, P. no.18, It. No. 2.11 aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.t111892.82111892.822.56FalseNoneNoneFalseNoneFalse286445.61920
3327962116582NoneVol - II, P. No. 14, It. No. 6.8Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. Cum9967.639967.6322.8FalseNoneNoneFalseNoneFalse227261.9640
3327963116582NoneVol - II, P. No. 14, It. No. 6.13Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:4 (1 cement :4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. Sqm1220.781220.7845.11FalseNoneNoneFalseNoneFalse55069.38580
3327964116582NoneVol - II, P. No. 100, It. No. 12.13.1Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. Cum123597.8123597.80.45FalseNoneNoneFalseNoneFalse55619.010
3327965116582NoneVol - II, P. No. 104, It. No. 12.51Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. Each1270.811270.814.0FalseNoneNoneFalseNoneFalse5083.240
3327966116582NoneVol - II, P. No. 219, It. No. 22.15.4Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge - SS Aldrop 16mm dia, 300mm Each469.05469.054.0FalseNoneNoneFalseNoneFalse1876.20
3327967116582NoneVol - II, P. No. 219, It. No. 22.15.1Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge - SS Handles 200mm Each562.86562.868.0FalseNoneNoneFalseNoneFalse4502.880
3327968116582NoneVol - II, P. No. 219, It. No. 22.15.6Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge - SS Tower Bolts 200x10mm Each187.62187.624.0FalseNoneNoneFalseNoneFalse750.480
3327969116582NoneVol - II, P. No. 219, It. No. 22.15.8Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge - SS hinges 125 mm Each62.5462.5416.0FalseNoneNoneFalseNoneFalse1000.640
3327970116582NoneVol - II, P. No. 69, It. No. 10.6.2Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm Each68.7968.7912.0FalseNoneNoneFalseNoneFalse825.480
3327971116582NoneVol - II, P. No. 205, It. No. 20.79Supplying and fixing new teak wood beads wherever necessary including cost of materials, labour, complete as per specifications. No65.0465.0424.0FalseNoneNoneFalseNoneFalse1560.960
3327972116582NoneVol - II, P. No. 105, It. No. 12.57.6Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 35 mm thick both side commercial Sqm4155.164155.1615.36FalseNoneNoneFalseNoneFalse63823.25760
3327973116582NoneVol - II, P. No. 110, It. No. 12.89Providing & fixing of 2.5 track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 94mm width x 45mm height with reinforcement of 1mm thickness and Sash with overall size of 39mm x 58mm with GI reinforcement of 1.5mm and mesh sash of size 25mm x 42mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 1819mm x 1819mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) Sqm8193.998193.999.6FalseNoneNoneFalseNoneFalse78662.3040
3327974116582NoneVol - II, P. No. 109, It. No. 12.85Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) Sqm7153.337153.330.72FalseNoneNoneFalseNoneFalse5150.39760
3327975116582NoneVol - II, P. No. 85, It. No. 11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding Kg210.13210.13206.64FalseNoneNoneFalseNoneFalse43421.26320
3327976116582NoneVol - II, P. No. 111, It. No. 12.93.1Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately) - Size 62 x 100mm Rmtr878.06878.069.8FalseNoneNoneFalseNoneFalse8604.9880
3327977116582NoneVol - II, P. No. 112, It. No. 12.94.1Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately) - 30 mm thickness Cum4359.044359.043.15FalseNoneNoneFalseNoneFalse13730.9760
3327978116582NoneVol - II, P. No. 42, It. No. 8.5.2Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sqm436.53436.53141.19FalseNoneNoneFalseNoneFalse61633.67070
3327979116582NoneVol - II, P. No. 43, It. No. 8.10Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sqm263.92263.9272.81FalseNoneNoneFalseNoneFalse19216.01520
3327980116582Noneol - II, P. No. 50, It. No. 8.51Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. Sqm125.08125.08214.0FalseNoneNoneFalseNoneFalse26767.120
3327981116582NoneVol - II, P. No. 42, It. No. 8.8Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (outside) Sqm464.05464.05146.23FalseNoneNoneFalseNoneFalse67858.03150
3327982116582NoneVol - II, P. No. 43, It. No. 8.16.1Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment Sqm42.5342.53676.2FalseNoneNoneFalseNoneFalse28758.7860
3327983116582NoneVol - II, P. No. 54, It. No. 8.79Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove. Rmtr65.0465.04271.01FalseNoneNoneFalseNoneFalse17626.49040
3327984116582NoneVol - II, P. No. 60, It. No. 9.12.2Providing and laying vitrified floor tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm Sqm1432.171432.1752.46FalseNoneNoneFalseNoneFalse75131.63820
3327985116582NoneVol - II, P. No. 40, It. No. 8.2.2Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sqm348.97348.9767.22FalseNoneNoneFalseNoneFalse23457.76340
3327986116582NoneVol - II, P. No. 60, It. No. 9.11Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thick- ness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. Sqm1111.961111.965.98FalseNoneNoneFalseNoneFalse6649.52080
3327987116582NoneVol - II, P. No. 64, It. No. 9.39Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. Sqm1812.411812.416.3FalseNoneNoneFalseNoneFalse11418.1830
3327988116582NoneVol - II, P. No. 48, It. No. 8.39Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sqm158.85158.85214.0FalseNoneNoneFalseNoneFalse33993.90
3327989116582NoneVol - II, P. No. 46, It. No. 8.31Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives with pure Acrylic Resin, UV resistant, dirt & pick up resistant, Alkali & Water resistant of required shade: New work (Two coats applied @ 1.43 L/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sqm222.64222.64146.23FalseNoneNoneFalseNoneFalse32556.64720
3327990116582NoneVol - II, P. No. 48, It. No. 8.40Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sqm143.84143.8462.22FalseNoneNoneFalseNoneFalse8949.72480
3327991116582NoneVol - II, P. No. 48, It. No. 8.38Painting with oil type wood preservative of approved brand and manufacture :New work (two coats) to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sqm50.0350.0325.2FalseNoneNoneFalseNoneFalse1260.7560
3327992116582NoneVol - II, P. No. 48, It. No. 9.24Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cat Eye, River Pink or equivalent. Sqm3567.283567.2813.5FalseNoneNoneFalseNoneFalse48158.280
3327993116582NoneVol - II, P. No. 48, It. No. 9.24Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. Kg706.7706.7119.07FalseNoneNoneFalseNoneFalse84146.7690
17189630510000NoneNoneBuildings3 Construction of Health and Welness Center at Madnoor in Aurad Taluk,Bidar District(Internal water supply & sanitary works)196185.86
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3327994116583NoneV-II, P. No. 28, It. No. 14.28.2.2Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. 40mm dia pipes, From wash basin waste lines Rmtr113.99113.994.0FalseNoneNoneFalseNoneFalse455.960
3327995116583NoneVol - V, P. no. 120, It. No. 10.14.9Providing and installing at site of work P.V.C. pipes including cost of pipes and specials and labour, including lowering into trenches, laying true to line, level and perfect linking at joints leak proof including jointing of approved type with all labour charges and all lift charges, handling charges including encasing the pipe around to a depth not less than 15 cms with gravel or selected earth available from the excavation etc. complete. PVC pipe - 75mm(weight of pipe -0.917 kg) Rmtr237.89237.8920.0FalseNoneNoneFalseNoneFalse4757.80
3327996116583NoneVol - V, P. no. 120, It. No. 10.14.11PVC pipe - OD 110mm and 6 Kg/sqcm, sanitary lines Rmtr443.56443.5650.0FalseNoneNoneFalseNoneFalse22178.00
3327997116583NoneVol - II, P. no. 136, It. No. 14.31Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. No1511.581511.584.0FalseNoneNoneFalseNoneFalse6046.320
3327998116583NoneVol - II, P. no. 123, It. No. 14.3.1Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid Each7405.57405.54.0FalseNoneNoneFalseNoneFalse29622.00
3327999116583NoneVol - II, P. no. 117, It. No. 13.3.1Providing and fixing brass stop cock of approved quality : 15 mm nominal bore Each370.46370.464.0FalseNoneNoneFalseNoneFalse1481.840
3328000116583NoneVol - II, P. no. 132, It. No. 14.7.1Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15mm C.P. brass pillar taps Each3818.63818.64.0FalseNoneNoneFalseNoneFalse15274.40
3328001116583NoneVol - II, P. No. 122, it. No. 13.32.2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. Rmtr469.58469.5860.0FalseNoneNoneFalseNoneFalse28174.80
3328002116583NoneVol - II, P. No. 122, It. No. 13.33.2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) External & Shafts & Terrace 20 mm nominal dia Pipes Rmtr268.86268.8620.0FalseNoneNoneFalseNoneFalse5377.20
3328003116583NoneVol - II, P. No. 122, It. No. 13.33.3Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) External & Shafts & Terrace 25 mm nominal dia Pipes Rmtr366.74366.7450.0FalseNoneNoneFalseNoneFalse18337.00
3328004116583NoneVol - V, P. No. 191, It. No. 16.9Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.(CATCH BASIN) No6757.516757.516.0FalseNoneNoneFalseNoneFalse40545.060
3328005116583NoneVol - II, P. no. 123, It. No. 13.34Providing and placing on terrace (at all floor levels) polyethylene water storage tank,IS:12701 marked,with cover and suitable locking arrangement and making necessary holes for inlet,outlet and overflow pipes but without fittings and the base support for tank. Ltr11.1511.152000.0FalseNoneNoneFalseNoneFalse22300.00
3328006116583NoneVol - II, P. no. 127, It. No. 13.59Providing and fixing PVC (S.W.R) Nahani Trap 10cms x 10cms with all fitting arrangements & all necessary accessories complete Ground Toilet 10Cms X 7.5Cms No272.58272.586.0FalseNoneNoneFalseNoneFalse1635.480
17189630510000NoneNoneBuildings3 Construction of Health and Welness Center at Madnoor in Aurad Taluk,Bidar District(Internal Electrification)438163.01
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3328007116584NoneCSR 2023-24 It.No 2.02.01Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point up to 3Mtr from tapping point to out let via switch Pack317.42317.4220.0FalseNoneNoneFalseNoneFalse6348.40
3328008116584NoneCSR 2023-24 It.No 2.2.2Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Medium point above 3mtr up to 6Mtr from tapping point to out let via switch Pack447.22447.2215.0FalseNoneNoneFalseNoneFalse6708.30
3328009116584NoneCSR 2023-24 It.No 2.2.3Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Above 6Mtr up to 10Mtr from tapping Point to out let via switch Pack654.9654.910.0FalseNoneNoneFalseNoneFalse6549.00
3328010116584NoneCSR 2023-24 It.No 3.4.2Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall Each187.62187.624.0FalseNoneNoneFalseNoneFalse750.480
3328011116584NoneCSR 2023-24 It.No 3.4.3Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 4-5Way Each208.86208.862.0FalseNoneNoneFalseNoneFalse417.720
3328012116584NoneCSR 2023-24 It.No 3.4.4Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 6Way Each259.6259.610.0FalseNoneNoneFalseNoneFalse2596.00
3328013116584NoneCSR 2023-24 It.No 3.4.5Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 8Way Each307.98307.985.0FalseNoneNoneFalseNoneFalse1539.90
3328014116584NoneCSR 2023-24 It.No 3.4.6Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 10-12Way Each376.42376.4210.0FalseNoneNoneFalseNoneFalse3764.20
3328015116584NoneCSR 2023-24 It.No 3.5.2Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 3 Module Each189.98189.984.0FalseNoneNoneFalseNoneFalse759.920
3328016116584NoneCSR 2023-24 It.No 3.5.3Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 4 Module Each276.12276.1210.0FalseNoneNoneFalseNoneFalse2761.20
3328017116584NoneCSR 2023-24, It.No 3.5.5Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 8 Module Each335.12335.125.0FalseNoneNoneFalseNoneFalse1675.60
3328018116584NoneCSR 2023-24 It.No 3.5.6Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 10-12 Module Each405.92405.9210.0FalseNoneNoneFalseNoneFalse4059.20
3328019116584NoneCSR 2023-24 It.No 3.6.1Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps one way. Each120.36120.36120.0FalseNoneNoneFalseNoneFalse14443.20
3328020116584NoneCSR 2023-24 It.No 3.6.3Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps 3way socket. Each201.78201.7820.0FalseNoneNoneFalseNoneFalse4035.60
3328021116584NoneCSR 2023-24, It.No 3.6.4Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Stepped Fan Regulator. Each421.26421.2610.0FalseNoneNoneFalseNoneFalse4212.60
3328022116584NoneCSR 2023-24, It.No 3.6.8Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 16Amps one way switch Each212.4212.420.0FalseNoneNoneFalseNoneFalse4248.00
3328023116584NoneCSR 2023-24 It.No 3.6.10Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 32Amps DP switch Each384.68384.684.0FalseNoneNoneFalseNoneFalse1538.720
3328024116584NoneCSR 2023-24 It.no 3.6.11Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6/16Amps universal socket Each278.48278.4810.0FalseNoneNoneFalseNoneFalse2784.80
3328025116584NoneCSR 2023-24 It.No 3.6.12Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. TV/Telephone socket Each184.08184.082.0FalseNoneNoneFalseNoneFalse368.160
3328026116584NoneCSR 2023-24 It.No 1.13Supplyin and Fixing Metal Fan Box with Round Hook. No138.06138.0610.0FalseNoneNoneFalseNoneFalse1380.60
3328027116584NoneCSR 2023-24 P.No 1.2.1Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 19/20mm dia 2mm thick Rmtr77.8877.8890.0FalseNoneNoneFalseNoneFalse7009.20
3328028116584NoneCSR 2023-24 It.No 1.2.2Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 25mm dia 2mm thick Rmtr92.0492.04150.0FalseNoneNoneFalseNoneFalse13806.00
3328029116584NoneCSR 2023-24 It.No 1.2.3Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 32mm dia 2mm thick Rmtr121.54121.5430.0FalseNoneNoneFalseNoneFalse3646.20
3328030116584NoneCSR 2023-24 It.No 1.7.1Extra for Groove cutting in brick wall/CC floor to the suitable depth for concealing of Conduit/GI pipe and plastering, finishing upto wall surface completeRmtr34.2234.2260.0FalseNoneNoneFalseNoneFalse2053.20
3328031116584NoneCSR 2023-24 It.No 2.3.2Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5 sqmm Rmtr30.6830.68180.0FalseNoneNoneFalseNoneFalse5522.40
3328032116584NoneCSR 2023-24 It.No 2.3.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.5 sqmm Rmtr49.5649.561080.0FalseNoneNoneFalseNoneFalse53524.80
3328033116584NoneCSR 2023-24 It.No 2.3.4Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 4 sqmm Rmtr74.3474.34360.0FalseNoneNoneFalseNoneFalse26762.40
3328034116584NoneCSR 2023-24 It.No 5.19.4Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure( Double Door) 12 Way SP & NEach2198.342198.342.0FalseNoneNoneFalseNoneFalse4396.680
3328035116584NoneCSR 2023-24 It.No 5.18.1Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32 A SPEach489.7489.720.0FalseNoneNoneFalseNoneFalse9794.00
3328036116584NoneCSR 2023-24 It.No 5.18.4Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898" 6-32 A DP Each872.02872.022.0FalseNoneNoneFalseNoneFalse1744.040
3328037116584None19-20SR P.No 6.4.4Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975 4 core 16 sqmm Km167373.56167373.560.25FalseNoneNoneFalseNoneFalse41843.390
3328038116584NoneCSR 2023-24 P.No 11.3.2Supplying of .feet - PVC Batten with integrated LED tube .W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. Each814.2814.220.0FalseNoneNoneFalseNoneFalse16284.00
3328039116584NoneCSR 2023-24 It.No 11.4.1Supplying & fixing of retrofit type - LED bulb.W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70%. efficacy 80 lumen per watt, life25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 5-6 W,Each949.9949.96.0FalseNoneNoneFalseNoneFalse5699.40
3328040116584NoneCSR 2023-24 It.No 6.1Supplying exhaust fan of 1440 RPM of 300mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply. Each1760.561760.566.0FalseNoneNoneFalseNoneFalse10563.360
3328041116584NoneCSR 2023-24 It.No 6.3.1Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system. 48" Sweep (1200mm) Regular model Each3521.123521.1210.0FalseNoneNoneFalseNoneFalse35211.20
3328042116584NoneCSR 2023-24 P.No 13.7.1Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall / ceiling / Rafter / Girders Each143.96143.9620.0FalseNoneNoneFalseNoneFalse2879.20
3328043116584NoneCSR 2023-24 It.No13.10Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S' hook with fan regulator to the existing board together with supplying and fixing 5 amps. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring. Each201.78201.7810.0FalseNoneNoneFalseNoneFalse2017.80
3328044116584NoneCSR 2023-34 13.13Fixing one exhaust fan after making a suitable nitch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 amps, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame. Each834.26834.266.0FalseNoneNoneFalseNoneFalse5005.560
3328045116584NoneCSR 2023-34 It.No 11.8.2Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with .W System Power consumption. LED Efficiency130lm/w, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Streetlight 40watts No4748.324748.322.0FalseNoneNoneFalseNoneFalse9496.640
3328046116584NoneCSR 2023-24 IT.No 13.4.1Supplying and fixing telescopic M.S. bracket fabricated by using 0.5m length 4” dia telescopic M. S. pipe, with 2” dia 1.5m long M. S. bracket and are welded with suitable angle, using 6mm thick M. S. sheet, grip bolts & nuts, as required, suitable for 9 to 12 Mtrs. M. S. tubular pole, with necessary two coats of painting, with all other accessories. Single bracket 1.5 Mtr. Length Each1723.981723.982.0FalseNoneNoneFalseNoneFalse3447.960
3328047116584NoneCSR 2023-24 It.No 13.5Fixing halogen/metal halide / SVL / IL / LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires. Each191.16191.161.0FalseNoneNoneFalseNoneFalse191.160
3328048116584NoneCSR 2023-24 It.No 5.42.2Fabricating supplying and mounting MS box made out .SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete 16SWG Sq CM0.510.5136000.0FalseNoneNoneFalseNoneFalse18360.00
3328049116584NoneCSR 2023-24 It.No 5.40.1Supplying .amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 100Amps 4x30x6mm Aluminum Strips Rmtr2908.72908.72.0FalseNoneNoneFalseNoneFalse5817.40
3328050116584NoneCSR 2023-24 It.No 5.41.1Supplying and fixing angle iron frame work iabricated out of M.S. angle iron. and M.S. flat . with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 40x40x6mm Rmtr359.9359.96.0FalseNoneNoneFalseNoneFalse2159.40
3328051116584NoneCSR 2023-24 It.No 5.15.1Supplying and fixing Moulded Case Circuit Breaker (MCCB) .over the existing wood/panel board using necessary screws, bolts, nuts and wiring complete. Protection of Overload and Short circuit with thermal Magnetic/Micro processor release and Earth Fault as per IS-13947. (lcu= lcs) FOUR POLE 100Amps 25kA Each7181.487181.481.0FalseNoneNoneFalseNoneFalse7181.480
3328052116584NoneCSR 2023-24 It.No 5.18.8Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 40Amps TPN Each3691.923691.922.0FalseNoneNoneFalseNoneFalse7383.840
3328053116584NoneCSR 2023-24 It.N0 5.18.4Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32Amps DP Each872.02872.026.0FalseNoneNoneFalseNoneFalse5232.120
3328054116584NoneCSR 2023-24 It.No 5.38 Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.C Each607.7607.72.0FalseNoneNoneFalseNoneFalse1215.40
3328055116584NoneCSR 2023-24 It.No 5.34 Supplying, fixing and wiring 50/5 to 400/5Amps 5VA burden Current Transformer. Class 0.5 accuracy with Tape Wound Each663.26663.263.0FalseNoneNoneFalseNoneFalse1989.780
3328056116584NoneCSR 2023-24 It.No 5.33Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH,KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy Each10991.710991.72.0FalseNoneNoneFalseNoneFalse21983.40
3328057116584NoneLUMPSUMElectrical Deposite for Power Sanction Lump Sum for Each35000.035000.01.0FalseNoneNoneFalseNoneFalse35000.00
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17189630540000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17189630540000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17189630540000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17189630540000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17189630540000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
17189630670000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17189630730000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by any State Government / Government of India /Union TerritoryNone
17189630780000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17189630890000NoneNoneELIGIBILITYThe bidder is required to ensure browser compatibility of the computer well in advance to the last date and time for receipt of tenders. The departments shall not be responsible for non-accessibility of e-Procurement portal due to internet connectivity issues and technical glitches at bidders end.None
17189630950000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
17189631020000NoneNoneELIGIBILITYBidder shall pay Contract Management Module processing fees of 0.025% of the contact value (Min Rs.500/- & Max Rs.7500/-) soon after contract has been issued to bidder.None
17189631100000NoneNoneELIGIBILITYThe tenderer shall bear all costs associated with the preparation and submission of his tender, and the employer will in no case be responsible and liable for those costs.None
17189631160000NoneNoneELIGIBILITYConditional tenders will not be accepted.None
17189631230000NoneNoneELIGIBILITYAll the formats prescribed in the bid document shall be filled by the tenderer in complete manner.None
17189631310000NoneNoneELIGIBILITYRoyalty on construction materials and other taxes will be deducted as per prevailing Govt., orders as may be modified from time to time.None
17189631370000NoneNoneELIGIBILITYAny discrepancies observed in the documents uploaded by the tenderer the tender shall liable to rejected.None
17189631670000NoneNoneELIGIBILITYEarnest Money Deposit will have to be in any one of the forms as per the instructions in the financial bid document and shall have to be valid for 45 days beyond the validity of the tender.None
17189631740000NoneNoneELIGIBILITYAll the formats prescribed in the bid documents shall be filled in complete manner. (section 2 & 3 of the bid document) and shall be uploaded properly, signed by tenderer. Necessary certificates shall be uploaded along with the formats wherever required. General documents section can be used for this purpose.None
17189631800000NoneNoneELIGIBILITYTenderers are required to read the Bid Documents carefully before submission of their bid.None
17189631860000NoneNoneELIGIBILITYIf the tenderer quotes bid price below the estimated contract value (Amount put to tender) then the tenderer has to submit the additional security deposit equal to the difference in cost and the additional security deposit should have a validity for the period of execution.None
17189631930000NoneNoneELIGIBILITYIf the numbers of page to be attached in one particular attachment is more, then all the pages can be put into one folder, zipped and then attached or else all the pages can be pasted in one word file and then this word file could be converted to PDF (portable documents format) format and then attached. (Please contract Help Desk for more assistance Phone: 080-25501216/ 25501227)None
17189631990000NoneNoneELIGIBILITYThe Contractor shall strictly take all reasonable steps to protect the environment on and off the site and to avoide damage or nuisance to persons or to property of the public or others resulting from pollution, noise or other causes arising as a consequence of his methods of operation.None
17189632040000NoneNoneELIGIBILITYMaterials like, steel(primary), cement, bitumen etc., required for the work shall be procured by the tenderer themselves and should be got tested positive by the quality control authority before use on the work.None
17189632110000NoneNoneELIGIBILITYSpecial Instructions to tenderers - asper bid document (F. Special Conditions of Contract Clause-6)None
17189632190000NoneNoneELIGIBILITYThe Defects Liability Period is 1 year from the date of completion of the work.None
17189632280000NoneNoneELIGIBILITYTotal value of Civil Engineering Construction works executed in the and payments received in the last five year i.e., 2019-20, 2020-21, 2021-22, 2022-23 & 2023-24.None
17189632330000NoneNoneELIGIBILITYThe Tenderers are bound to furnish the original certified documents to the employer within weeks time from the day of opening of technical bid for verification, failing which the bid of tenderer will be considered as technically non responsive.None
17189632380000NoneNoneELIGIBILITYTenderer should have latest GST registration & upload latest GST/VAT clearance certificate in their nameNone
17189632460000NoneNoneELIGIBILITYThe Rates quoted by the tenderer shall be Inclusive of GSTNone
17189632530000NoneNoneELIGIBILITYThe contractor shall strictly take all reasonable steps to protect the environment on and off the site and to avoid damage or nuisance to persons or to property of the public or others resulting from pollution, noise or other causes arising as a consequence of his methods of operationNone
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneMinimum financial turnover (civil engineering construction works) not less than two times the annual payments from this contract (Rs. xxxxx Lakhs)NoneNone
NoneNoneNoneNoneSatisfactoriy completed (atleast 90%) as prime contractor at-least one such similar work of value not less than Rs. xxxxxxx (80% of estimated cost of tender)NoneNone
NoneNoneNoneNoneExecuted in any one year the following minimum quantities of work (Cement Concrete - xxxx cum, Earthwork - xxxx cum, etc) (80% of peak rate of construction)NoneNone
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid Electrical License for executing building electrificatio works and should have executed similar electrical works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid license for executing water supply / sanitary engineering works and should have executed similar works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneOwning the following key and critical equipment for this work (xxxx, xxxx, xxxx)NoneNone
NoneNoneNoneNoneLiquid assets and /or availability of credit facilities of no less than Rs. xxxxxx Lakhs (estimated cash flow for 3 months of peak construction period)NoneNone
NoneNoneNoneNoneTotal value of civl engineering works executed and payments received in the last five years (year-wise)NoneNone
NoneNoneNoneNoneList of existing commitments and ongoing worksNoneNone
NoneNoneNoneNoneList of works for which tenders already submittedNoneNone
NoneNoneNoneNoneBanker Details for referenceNoneNone
NoneNoneNoneNoneConstruction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneReports on the financial standing of the tenderer, such as profit and loss statements and auditor’s reports for the last five yearsNoneNone
NoneNoneNoneNoneQualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneList of Financial Resources with CertificatesNoneNone
NoneNoneNoneNoneClause ITT 3.2aTo qualify for award of this contract, each Tenderer in his/its name should have in the last five years i.e.(2019-20 to 2023-24) The tenderer should have been achieved in at least two financial years a minimum annual financial turnover (in all classes of civil Engineering construction works only) of Rs.388.34 LakhsPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNoneClause ITT 3.2bTo qualify for award of this contract,each Tenderer in his/its name should have in the last five years i.e.(2019-20 to 2023-24)The tenderer should have been Satisfactorily completed at least one Similar work of value not less than Rs.97.10 Lakhs as prime contractor.Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneClause ITT 3.2(c): To qualify for award of this contract,each Tenderer in his/its name should have in the last five years i.e.(2019-20 to 2023-24).Executed in any one financial year,the following minimum quantities of work Sl.No Description of key items of works 1. Earthwork Excavation in all kinds of soil 1188.00 Cum 2.PCC & RCC 314.00 Cum 3. Steel Reinforcement for RCC work (TMT Steel) 26.66 Tonnes 4.BBM/Concrete Blocks 130.00 Cum. 5. Flooring (Vitrified/Granite/Ceramic) 592.00 Sqm 6. Plastering 2384.00 Sqm 7. Painting 2514.00 Sqm 8. MS Grill 992.00 Kgs Note:The Work done certificate should be issued by the Officer not less than the rank of Executive Engineer of State or Central Government/Semi Government/Government undertaking/ autonomous bodies of Government will be considered, for the clause 3.2 (c)Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneClause ITT 3.2d The tenderer or his identified sub contractor should possess required valid electrical license issued by KPWD,Government electrical Inspectorate for executing building electrification works and should have executed similar Building electrical works totaling to Rs.6.58 Lakhs in any one year Note.The Work done certificate should be issued by the Officer not less than the rank of Executive Engineer of State or Central Government,Semi Government,Government undertaking,autonomous bodies of Government will be considered, for the clause 3.2d.Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneClause ITT 3.2(e):The Tenderer or his identified sub-contractor should possess valid license issued by BWSSB/KUWS&DB for executing water supply/sanitary engineering works and should have executed similar building water supply/sanitary engineering works totaling to Rs.2.95 Lakhs in any one year Note : The Work done certificate should be issued by the Officer not less than the rank of Executive Engineer of State or Central Government/Semi Government/Government undertaking/ autonomous bodies of Government will be considered, for the clause 3.2 (e).Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneClass III & Above PWD Registered CertificateCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNonePWD Registration Certificate (Class I/II/III/IV)
NoneNoneNoneNoneClause ITT 3.6 Tenderers who meet the above specified minimum qualifying criteria,will only be qualified, if their available tender capacity is more than the total tender value. The available tender capacity will be calculated as under Assessed available tender capacity(AxNx1.5-B)where A Maximum value of civil engineering works executed in any one year during the last five years i.e (2019-20-2023-24)(updated to 2024-25 price level)taking into account the completed as well as works in progress .N Number of years prescribed for completion of the works for which tender are invited. B Value at 2024-25 price level, of existing commitments of and ongoing works to be Completed during the next 6 months .Note:(1)The statements showing the value of existing commitments and on-going works as well as the stipulated period of completion remaining for each of the works listed should be countersigned by the Employer in charge, not below the rank of an Executive Engineer or equivalent(2)Tenderer shall submit the list of Ongoing works duly certified by the Auditor/Chartered Accountant.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Certificate issued by the officer not lessthan the rank of Executive Engineer Ongoing commitments and Bids submitted for the works
NoneNoneNoneNoneList of Minimum Key Personnel to be deployed by the contractor at site for Contract work 1) Site Engineer (Civil) B.E. Civil with minimum experience of 5 years in the Construction of buildings OR Diploma in Civil Engineering with minimum experience of 10 years in the Construction of buildings and should have been working in permanent role of the organization for at least two years 1 (One) 2) Site Engineer (Electrical Engineer) B.E. Electrical with minimum experience of 5 years in the Construction of buildings Diploma in Electrical Engineering with minimum experience of 10 years in the Construction of buildings and should have been working in permanent role of the organization for at least two years 1 (One) Note: 1) The tenderer shall submit list and photo identity proof such as Aadhar Card/Voter ID/Employee ID/Pass port/Driving License etc., for the key personnel such as project manager/site engineer to be deployed at each of the worksite. 2) The key personnel deployed at the site for this work should be working for a minimum period of one year with the tenderers and experience certificate has to be furnished in this regard.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Educational and Experience certificates
NoneNoneNoneNoneClause ITT 3.3(b):Liquid assets and/or availability of credit facilities of not less than Rs.58.30 Lakhs (Credit lines/letter of credit/certificates from banks for meeting the fund requirement etc.,)Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneLine of Credit
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Annual Turnover CertificateTrueTechnical Bid
PWD Registration CertificateTrueTechnical Bid
GST Category CertificateTrueTechnical Bid
tenderWorkLocationList
tenderAddress
createdTs1719224162000
version0
createdDateNone
modifiedDateNone
blockNumberOffice of the Chief Engineer, Health and Family Welfare Department, Engineering Wing, 3rd Floor Arogya Soudha 1st Cross Magadi Road
streetNone
cityBengaluru
stateKarnataka
pin560023
tenderRecallDTONone