tenderSubEstimateList | createdTs | version | createdDate | modifiedDate | workCategoryName | subEstimateName | estimateTotal | itemList |
---|
1719297809000 | 0 | None | None | Buildings | GROUND FLOOR | 19803544.21 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3342766 | 117455 | None | 2.5A | Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness.By Mechanical Means using Dozer In area of light jungle ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Sqm | 486.93 | 486.93 | 6.94 | False | None | None | False | None | False | 3379.2942 | 0 | 3342767 | 117455 | None | 1.12 | Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depth
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Cum | 117.71 | 117.71 | 346.8 | False | None | None | False | None | False | 40821.828 | 0 | 3342768 | 117455 | None | 1.14.1 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Cum | 126.38 | 126.38 | 502.47 | False | None | None | False | None | False | 63502.1586 | 0 | 3342769 | 117455 | None | 1.15.1 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In ordinary/soft rock without blasting upto 1.5 m depth
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Cum | 449.76 | 449.76 | 54.57 | False | None | None | False | None | False | 24543.4032 | 0 | 3342770 | 117455 | None | 1.A | Loading and Unloading of Stone Boulder/Stone aggregates/ Sand/Kankar/Moorum
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Cum | 167.27 | 167.27 | 104.57 | False | None | None | False | None | False | 17491.4239 | 0 | 3342771 | 117455 | None | 4.1 | Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications.
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Sqm | 146.2 | 146.2 | 624.4 | False | None | None | False | None | False | 91287.28 | 0 | 3342772 | 117455 | None | 1.9 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Cum | 329.57 | 329.57 | 503.73 | False | None | None | False | None | False | 166014.2961 | 0 | 3342773 | 117455 | None | 1.8 | Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work.
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Cum | 587.29 | 587.29 | 354.37 | False | None | None | False | None | False | 208117.9573 | 0 | 3342774 | 117455 | None | 2.1.3 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Cum | 7420.37 | 7420.37 | 145.01 | False | None | None | False | None | False | 1076027.8537 | 0 | 3342775 | 117455 | None | 2.2.1 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. 2.2.1 M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
FOR FOOTINGS ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Cum | 8412.76 | 8412.76 | 139.95 | False | None | None | False | None | False | 1177365.762 | 0 | 3342776 | 117455 | None | 2.2.1 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. 2.2.1 M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR PEDESTAL ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Cum | 8568.55 | 8568.55 | 7.34 | False | None | None | False | None | False | 62893.157 | 0 | 3342777 | 117455 | None | 2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
COLUMNS ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Cum | 14413.41 | 14413.41 | 33.26 | False | None | None | False | None | False | 479390.0166 | 0 | 3342778 | 117455 | None | 2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
PLINTHBEAM ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Cum | 12717.72 | 12717.72 | 52.34 | False | None | None | False | None | False | 665645.4648 | 0 | 3342779 | 117455 | None | 2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
RCC BEAMS ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Cum | 13565.56 | 13565.56 | 29.99 | False | None | None | False | None | False | 406831.1444 | 0 | 3342780 | 117455 | None | 2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
RCC SLAB ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Cum | 12717.72 | 12717.72 | 91.58 | False | None | None | False | None | False | 1164688.7976 | 0 | 3342781 | 117455 | None | 2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
LINTELS ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Cum | 13565.56 | 13565.56 | 10.7 | False | None | None | False | None | False | 145151.492 | 0 | 3342782 | 117455 | None | 2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
STAIRCASE ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Cum | 12717.72 | 12717.72 | 6.1 | False | None | None | False | None | False | 77578.092 | 0 | 3342783 | 117455 | None | 2.1.4 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Cum | 11550.02 | 11550.02 | 7.83 | False | None | None | False | None | False | 90436.6566 | 0 | 3342784 | 117455 | None | 15.4 | Providing and inserting nipples with approved fixing compound after drilling holes for grouting as per Technical Specifications including subsequent cutting/removal and sealing of the hole as necessary of nipples after completion of grouting with Cement/Epoxy
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | No | 252.76 | 252.76 | 10.0 | False | None | None | False | None | False | 2527.6 | 0 | 3342785 | 117455 | None | 8.16.A | KSRB 4-5 :Providing Lath plaster with cement mortar 1:3 5cm thick with 6mm dia mild steel bars at 20cms. C to c both horizontally and vertically fixing chicken mesh for drop chejjas, facia, backing to cup board including cost of all materials, labour, providing and removing form work HOM of machineries, curing, complete as per specification.
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Sqm | 1533.88 | 1533.88 | 5.58 | False | None | None | False | None | False | 8559.0504 | 0 | 3342786 | 117455 | None | 2.11A | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement
including cost of all materials, machinery, labour, cleaning, straightening,
cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Tonne | 110837.22 | 110837.22 | 49.56 | False | None | None | False | None | False | 5493092.6232 | 0 | 3342787 | 117455 | None | 4.21 | KSRB 4-2.12 : Extra for providing throating or drip moulding to RCC chejjas with plastering ( labour charges only ) as per specifications. Specification No . KBS
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Rmtr | 70.0 | 70.0 | 96.9 | False | None | None | False | None | False | 6783.0 | 0 | 3342788 | 117455 | None | 5.4 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Cum | 7915.97 | 7915.97 | 14.35 | False | None | None | False | None | False | 113594.1695 | 0 | 3342789 | 117455 | None | 6.32 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Sqm | 1623.09 | 1623.09 | 743.5 | False | None | None | False | None | False | 1206767.415 | 0 | 3342790 | 117455 | None | 6.34 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Sqm | 1367.86 | 1367.86 | 309.09 | False | None | None | False | None | False | 422791.8474 | 0 | 3342791 | 117455 | None | 12.13.1 | Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications.
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Cum | 122431.79 | 122431.79 | 0.79 | False | None | None | False | None | False | 96721.1141 | 0 | 3342792 | 117455 | None | 12.51 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications.
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | No | 1258.82 | 1258.82 | 15.0 | False | None | None | False | None | False | 18882.3 | 0 | 3342793 | 117455 | None | 12.60 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | No | 1303.43 | 1303.43 | 15.0 | False | None | None | False | None | False | 19551.45 | 0 | 3342794 | 117455 | None | 12.61 | Providing and fixing chromium plated brass night latch of approved quality including necessary screws etc. complete.
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | No | 1226.61 | 1226.61 | 15.0 | False | None | None | False | None | False | 18399.15 | 0 | 3342795 | 117455 | None | 12.62 | Providing and fixing chromium plated brass handles of 100/125 mm with
necessary screws etc. complete"
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | No | 293.64 | 293.64 | 30.0 | False | None | None | False | None | False | 8809.2 | 0 | 3342796 | 117455 | None | 12.63 | Providing and fixing aluminium tower bolts, ISI marked, anodised (an- odic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | No | 161.07 | 161.07 | 30.0 | False | None | None | False | None | False | 4832.1 | 0 | 3342797 | 117455 | None | 12.64 | Providing and fixing PTMT door catcher of length 72 mm and dia. of 42 mm with suitable washers weighing not less than 33 gms
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | No | 68.15 | 68.15 | 15.0 | False | None | None | False | None | False | 1022.25 | 0 | 3342798 | 117455 | None | 12.75.1 | Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : 125x85x5.5 mm (heavy type)
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | No | 340.73 | 340.73 | 30.0 | False | None | None | False | None | False | 10221.9 | 0 | 3342799 | 117455 | None | 10.6.3 | Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | No | 74.34 | 74.34 | 90.0 | False | None | None | False | None | False | 6690.6 | 0 | 3342800 | 117455 | None | 309 (0115) 2018-19 SR | Providing & Fixing of corner beads of wooden door frame to wall including cost of materials, labour charges, complete as per specifications.
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | No | 15.75 | 15.75 | 95.6 | False | None | None | False | None | False | 1505.7 | 0 | 3342801 | 117455 | None | 12.57.6 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 35 mm thick both side commercial
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Sqm | 4115.96 | 4115.96 | 34.23 | False | None | None | False | None | False | 140889.3108 | 0 | 3342802 | 117455 | None | 12.90 | Providing & fixing of 3-track x 2panel sliding windows made out of multi chambered UPVC (Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE (Therma Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Sqm | 8343.43 | 8343.43 | 53.4 | False | None | None | False | None | False | 445539.162 | 0 | 3342803 | 117455 | None | 12.85 | Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Sqm | 7085.84 | 7085.84 | 7.02 | False | None | None | False | None | False | 49742.5968 | 0 | 3342804 | 117455 | None | 11.34A | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Kg | 208.15 | 208.15 | 1268.82 | False | None | None | False | None | False | 264104.883 | 0 | 3342805 | 117455 | None | 12.54 | Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge.
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Rmtr | 394.0 | 394.0 | 70.0 | False | None | None | False | None | False | 27580.0 | 0 | 3342806 | 117455 | None | 12.55.2 | Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges.- with one side prelam ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Sqm | 2527.56 | 2527.56 | 23.52 | False | None | None | False | None | False | 59448.2112 | 0 | 3342807 | 117455 | None | 12.59 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete.
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | No | 1380.25 | 1380.25 | 15.0 | False | None | None | False | None | False | 20703.75 | 0 | 3342808 | 117455 | None | 8.10 | Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3
fine sand) on concrete surface / ceilings including rounding off corners
wherever required smooth rendering, providing and removing scaffolding,
including cost of materials, labour, curing complete as per specifications
and as per directions of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Sqm | 261.43 | 261.43 | 1559.25 | False | None | None | False | None | False | 407634.7275 | 0 | 3342809 | 117455 | None | 8.51 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Sqm | 123.9 | 123.9 | 2482.71 | False | None | None | False | None | False | 307607.769 | 0 | 3342810 | 117455 | None | 8.5.2 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( Outside)
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Sqm | 432.41 | 432.41 | 390.3 | False | None | None | False | None | False | 168769.623 | 0 | 3342811 | 117455 | None | 8.79 | Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove.
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Rmtr | 64.43 | 64.43 | 529.2 | False | None | None | False | None | False | 34096.356 | 0 | 3342812 | 117455 | None | 9.21.2 | Providing and laying Vitrified tiles in floor with different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).).Size of Tile 600x600 mm
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Sqm | 1533.88 | 1533.88 | 626.96 | False | None | None | False | None | False | 961681.4048 | 0 | 3342813 | 117455 | None | 9.20.2 | Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge Size of Tile 600x600 mm
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Sqm | 258.95 | 258.95 | 626.96 | False | None | None | False | None | False | 162351.292 | 0 | 3342814 | 117455 | None | 9.23 | Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge :
** Flamed finish granite stone slab Black, Cherry Red, Brown, Cat Eye,
River Pink or equivalent. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Sqm | 3055.37 | 3055.37 | 216.57 | False | None | None | False | None | False | 661701.4809 | 0 | 3342815 | 117455 | None | 9.30 | Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Sqm | 6601.39 | 6601.39 | 60.09 | False | None | None | False | None | False | 396677.5251 | 0 | 3342816 | 117455 | None | 10.1.2 | Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, pre moulded and pre polished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, Moulding and polishing to edges to give high gloss finish etc. complete at all levels. Area of slab over 0.50 m2 ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Sqm | 4877.94 | 4877.94 | 31.14 | False | None | None | False | None | False | 151899.0516 | 0 | 3342817 | 117455 | None | 8.2.1 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Sqm | 365.51 | 365.51 | 285.48 | False | None | None | False | None | False | 104345.7948 | 0 | 3342818 | 117455 | None | 15.7 | Providing and supplying crystalline integral concrete waterproofing admixture that waterproofs concrete by forming crystals deep in the pores, capillaries and microcracks of the concrete, self-seal waterproofing compound to bridge shrinkage cracks upto 0.5mm in width & resist hydro-static pressure upto 16bar for both positive & negative pressure confirming to DIN 1048 part 5 for 56% reduction in depth of penetration against control, resistance to chloride penetration confirming to ASTM C 1202 with 64% improvement against control & protecting steel re-inforcement against corrosion mixed @ 1% by weight of cementitious content in concrete. ie., integral crystaline waterproofing admix @ 0.5 kg/bag of cement. (For calculation purpose 320 kg of Cement for M-20 grade of Concrete is considered in the analysis)
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Sqm | 761.99 | 761.99 | 98.29 | False | None | None | False | None | False | 74895.9971 | 0 | 3342819 | 117455 | None | 9.11 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 including pointing the joints with white cement and matching pigment etc., complete.
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Sqm | 1101.47 | 1101.47 | 59.66 | False | None | None | False | None | False | 65713.7002 | 0 | 3342820 | 117455 | None | 9.39 | Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications.
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Sqm | 1795.31 | 1795.31 | 285.48 | False | None | None | False | None | False | 512525.0988 | 0 | 3342821 | 117455 | None | 8.39 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Sqm | 157.35 | 157.35 | 2482.71 | False | None | None | False | None | False | 390654.4185 | 0 | 3342822 | 117455 | None | 8.32 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Sqm | 193.28 | 193.28 | 390.3 | False | None | None | False | None | False | 75437.184 | 0 | 3342823 | 117455 | None | 8.34.3 | Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Sqm | 61.95 | 61.95 | 60.42 | False | None | None | False | None | False | 3743.019 | 0 | 3342824 | 117455 | None | 8.40 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Sqm | 142.49 | 142.49 | 60.42 | False | None | None | False | None | False | 8609.2458 | 0 | 3342825 | 117455 | None | 8.34.1 | Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Sqm | 65.67 | 65.67 | 82.15 | False | None | None | False | None | False | 5394.7905 | 0 | 3342826 | 117455 | None | 8.47 | Polishing on wood work with ready mixed wax polish of approved brand and manufacture : New work to give an even surface including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Sqm | 167.27 | 167.27 | 82.15 | False | None | None | False | None | False | 13741.2305 | 0 | 3342827 | 117455 | None | 11.16.2 | Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Kg | 182.13 | 182.13 | 945.0 | False | None | None | False | None | False | 172112.85 | 0 | 3342828 | 117455 | None | 18.1 | Providing and supplying aluminium extruded tubular and other alu- minium sections as per the architectural drawings and approved draw- ings of Chief Architect, GoK.The aluminium quality shall be as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. ( The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account).The weight of aluminium extruded section shall be taken for purpose of payment.
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Kg | 504.27 | 504.27 | 409.5 | False | None | None | False | None | False | 206498.565 | 0 | 3342829 | 117455 | None | 18.3 | Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically sealed 6-12- 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick of approved color and shade with reflective soft coating on surface no.2 of approved colour and shade an innter heat strenghted clear float glass 6mm thick spacer tube 12mm wide dessicants, including primary seal and secondtry seal (structural silcone sealant) etc allcomplete for the required performances as per the Architectural drawings as per the approved shop drawings as specified and as directed by the engineer in charge the 1GUS shall be assembled in the factory workshop of the flass processror (payment for fixing of IGU panels in the curtain glazing is included shall be assembled in the factory/ workshop of the glass processor. (Payment for fixing of IGU Panels ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Sqm | 3770.28 | 3770.28 | 63.0 | False | None | None | False | None | False | 237527.64 | 0 | 3342830 | 117455 | None | A.R | The Tenderer (agency) should arrange to obtain (get), detailed Architectural drawings and elevations, Structural designs and drawings including Soil exploration &proof checking by reputedGovernment/Semi Government/IISC /IIT/NIT/or as decided by the Department and the same has to be furnished to the Department for approval and providing consultancy for Architectural designs & drawings, elevation, 3D view, MFP design and Drawings, Internal and External Electrical services including electrical infrastructure, etc. Interior layout and liaison with other department and approval of pollution control board and allied works etc., and any other drawings related to this project and 6 sets of as built drawings should be submitted to the employer. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Job | 270000.0 | 270000.0 | 1.0 | False | None | None | False | None | False | 270000.0 | 0 |
| 1719297809000 | 0 | None | None | Buildings | FIRST FLOOR | 14634052.23 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3342831 | 117456 | None | 2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
FF COLUMNS ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Cum | 14417.14 | 14417.14 | 24.19 | False | None | None | False | None | False | 348750.6166 | 0 | 3342832 | 117456 | None | 2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
FF RCC BEAMS ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Cum | 13569.07 | 13569.07 | 28.98 | False | None | None | False | None | False | 393231.6486 | 0 | 3342833 | 117456 | None | 2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
FF RCC SLAB ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Cum | 12721.01 | 12721.01 | 92.58 | False | None | None | False | None | False | 1177711.1058 | 0 | 3342834 | 117456 | None | 2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
FF RCC STAIRCASE ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Cum | 12721.01 | 12721.01 | 5.84 | False | None | None | False | None | False | 74290.6984 | 0 | 3342835 | 117456 | None | 2.1.4 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Cum | 11665.52 | 11665.52 | 9.37 | False | None | None | False | None | False | 109305.9224 | 0 | 3342836 | 117456 | None | 17.4 | Providing and inserting nipples with approved fixing compound after drilling holes for grouting as per Technical Specifications including subsequent cutting/removal and sealing of the hole as necessary of nipples after completion of grouting with Cement/Epoxy
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | No | 255.28 | 255.28 | 10.0 | False | None | None | False | None | False | 2552.8 | 0 | 3342837 | 117456 | None | 11.32 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement
including cost of all materials, machinery, labour, cleaning, straightening,
cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Tonne | 111945.6 | 111945.6 | 25.51 | False | None | None | False | None | False | 2855732.256 | 0 | 3342838 | 117456 | None | 4.21 | KSRB 4-2.12 : Extra for providing throating or drip moulding to RCC chejjas with plastering ( labour charges only ) as per specifications. Specification No . KBS
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Rmtr | 91.35 | 91.35 | 108.6 | False | None | None | False | None | False | 9920.61 | 0 | 3342839 | 117456 | None | 6.32 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Sqm | 1639.32 | 1639.32 | 982.32 | False | None | None | False | None | False | 1610336.8224 | 0 | 3342840 | 117456 | None | 6.34 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Sqm | 1381.53 | 1381.53 | 354.24 | False | None | None | False | None | False | 489393.1872 | 0 | 3342841 | 117456 | None | 12.13.1 | Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications.
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Cum | 123656.1 | 123656.1 | 0.97 | False | None | None | False | None | False | 119946.417 | 0 | 3342842 | 117456 | None | 12.50 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications.
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | No | 1271.41 | 1271.41 | 19.0 | False | None | None | False | None | False | 24156.79 | 0 | 3342843 | 117456 | None | 12.60 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | No | 1316.46 | 1316.46 | 19.0 | False | None | None | False | None | False | 25012.74 | 0 | 3342844 | 117456 | None | 12.61 | Providing and fixing chromium plated brass night latch of approved quality including necessary screws etc. complete.
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | No | 1238.88 | 1238.88 | 19.0 | False | None | None | False | None | False | 23538.72 | 0 | 3342845 | 117456 | None | 12.62 | Providing and fixing chromium plated brass handles of 100/125 mm with
necessary screws etc. complete
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | No | 296.58 | 296.58 | 38.0 | False | None | None | False | None | False | 11270.04 | 0 | 3342846 | 117456 | None | 12.63 | Providing and fixing aluminium tower bolts, ISI marked, anodised (an- odic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | No | 162.68 | 162.68 | 38.0 | False | None | None | False | None | False | 6181.84 | 0 | 3342847 | 117456 | None | 12.64 | Providing and fixing PTMT door catcher of length 72 mm and dia. of 42 mm with suitable washers weighing not less than 33 gms
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | No | 68.83 | 68.83 | 19.0 | False | None | None | False | None | False | 1307.77 | 0 | 3342848 | 117456 | None | 12.75.1 | Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : 125x85x5.5 mm (heavy type)
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | No | 344.13 | 344.13 | 38.0 | False | None | None | False | None | False | 13076.94 | 0 | 3342849 | 117456 | None | 10.6.3 | Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | No | 75.08 | 75.08 | 114.0 | False | None | None | False | None | False | 8559.12 | 0 | 3342850 | 117456 | None | 309 (0115) | Providing & Fixing of corner beads of wooden door frame to wall including cost of materials, labour charges, complete as per specifications.
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Rmtr | 15.91 | 15.91 | 117.8 | False | None | None | False | None | False | 1874.198 | 0 | 3342851 | 117456 | None | 12.57.6 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 35 mm thick both side commercial
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Sqm | 4157.12 | 4157.12 | 39.9 | False | None | None | False | None | False | 165869.088 | 0 | 3342852 | 117456 | None | 12.90 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Sqm | 8426.86 | 8426.86 | 56.7 | False | None | None | False | None | False | 477802.962 | 0 | 3342853 | 117456 | None | 12.85 | Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Sqm | 7156.7 | 7156.7 | 10.8 | False | None | None | False | None | False | 77292.36 | 0 | 3342854 | 117456 | None | 11.34A | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Kg | 210.23 | 210.23 | 1417.5 | False | None | None | False | None | False | 298001.025 | 0 | 3342855 | 117456 | None | 12.54 | Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge.
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Rmtr | 397.94 | 397.94 | 118.8 | False | None | None | False | None | False | 47275.272 | 0 | 3342856 | 117456 | None | 12.55.2 | Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges.- with one side prelam
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Sqm | 2552.84 | 2552.84 | 37.8 | False | None | None | False | None | False | 96497.352 | 0 | 3342857 | 117456 | None | 12.59 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete.
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Sqm | 1394.05 | 1394.05 | 19.0 | False | None | None | False | None | False | 26486.95 | 0 | 3342858 | 117456 | None | 8.10 | Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3
fine sand) on concrete surface / ceilings including rounding off corners
wherever required smooth rendering, providing and removing scaffolding,
including cost of materials, labour, curing complete as per specifications
and as per directions of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Sqm | 264.04 | 264.04 | 1715.31 | False | None | None | False | None | False | 452910.4524 | 0 | 3342859 | 117456 | None | 8.51 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Sqm | 125.14 | 125.14 | 2608.42 | False | None | None | False | None | False | 326417.6788 | 0 | 3342860 | 117456 | None | 8.5.2 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( Outside)
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Sqm | 436.74 | 436.74 | 634.14 | False | None | None | False | None | False | 276954.3036 | 0 | 3342861 | 117456 | None | 8.79 | Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove.
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Rmtr | 65.07 | 65.07 | 529.2 | False | None | None | False | None | False | 34435.044 | 0 | 3342862 | 117456 | None | 9.21.2 | Providing and laying Vitrified tiles in floor with different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).).Size of Tile 600x600 mm
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Sqm | 1549.22 | 1549.22 | 340.0 | False | None | None | False | None | False | 526734.8 | 0 | 3342863 | 117456 | None | 9.23 | Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge :
** Flamed finish granite stone slab Black, Cherry Red, Brown, Cat Eye,
River Pink or equivalent. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Sqm | 3085.93 | 3085.93 | 279.0 | False | None | None | False | None | False | 860974.47 | 0 | 3342864 | 117456 | None | 9.30 | Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Sqm | 6667.41 | 6667.41 | 31.5 | False | None | None | False | None | False | 210023.415 | 0 | 3342865 | 117456 | None | 8.2.1 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Sqm | 369.16 | 369.16 | 412.92 | False | None | None | False | None | False | 152433.5472 | 0 | 3342866 | 117456 | None | 15.7 | Providing and supplying crystalline integral concrete waterproofing admixture that waterproofs concrete by forming crystals deep in the pores, capillaries and microcracks of the concrete, self-seal waterproofing compound to bridge shrinkage cracks upto 0.5mm in width & resist hydro-static pressure upto 16bar for both positive & negative pressure confirming to DIN 1048 part 5 for 56% reduction in depth of penetration against control, resistance to chloride penetration confirming to ASTM C 1202 with 64% improvement against control & protecting steel re-inforcement against corrosion mixed @ 1% by weight of cementitious content in concrete. ie., integral crystaline waterproofing admix @ 0.5 kg/bag of cement. (For calculation purpose 320 kg of Cement for M-20 grade of Concrete is considered in the analysis)
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Sqm | 769.6 | 769.6 | 138.66 | False | None | None | False | None | False | 106712.736 | 0 | 3342867 | 117456 | None | 7.18 | Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications.
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Cum | 2524.05 | 2524.05 | 24.7 | False | None | None | False | None | False | 62344.035 | 0 | 3342868 | 117456 | None | 9.11 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 including pointing the joints with white cement and matching pigment etc., complete.
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Sqm | 1112.49 | 1112.49 | 82.32 | False | None | None | False | None | False | 91580.1768 | 0 | 3342869 | 117456 | None | 9.39 | Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications.
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Sqm | 1813.26 | 1813.26 | 412.92 | False | None | None | False | None | False | 748731.3192 | 0 | 3342870 | 117456 | None | 8.39 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Sqm | 158.93 | 158.93 | 2608.42 | False | None | None | False | None | False | 414556.1906 | 0 | 3342871 | 117456 | None | 8.32 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Sqm | 195.22 | 195.22 | 634.14 | False | None | None | False | None | False | 123796.8108 | 0 | 3342872 | 117456 | None | 8.34.3 | Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Sqm | 62.57 | 62.57 | 67.5 | False | None | None | False | None | False | 4223.475 | 0 | 3342873 | 117456 | None | 8.40 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Sqm | 143.91 | 143.91 | 67.5 | False | None | None | False | None | False | 9713.925 | 0 | 3342874 | 117456 | None | 8.34.1 | Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Sqm | 66.32 | 66.32 | 95.76 | False | None | None | False | None | False | 6350.8032 | 0 | 3342875 | 117456 | None | 8.47 | Polishing on wood work with ready mixed wax polish of approved brand and manufacture : New work to give an even surface including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Sqm | 168.94 | 168.94 | 95.76 | False | None | None | False | None | False | 16177.6944 | 0 | 3342876 | 117456 | None | 15.12 | Newly Constructed Roof/Podium with PU Waterproof coating Above 500 m2. Providing and Applying single component Polyurethane based cold applied seamless waterproofing coating to the RCC surface like Roof & Podium area applied @ 2.4kg/m2 in 3 coats to achieve 1.5mm DFT, including a prime coat of solvent free, medium viscous, epoxy primer @0.2L/m2 and protection with 120gsm Geo-textile over the 7 days cured waterproofing membrane. The Waterproofing material shall have Solids 85%, Tensile strength 2 Mpa as per ASTM D 412, Elongation at break 400% confirms to ASTM C 1305 for crack bridging ability (no cracks up to 3.2mm) Shore A Hardness 55 as per ASTM D 2240, Adhesion to peel after water immersion as per ASTM C 794 at 5.2N. Resistance to root penetration as per UNE CN TS 14416. The finished cost to include surface preparation, making coving of 50 mm X 50mm at all right angles of wall Junction with Polymer Repair Mortar and lay 60gsm Geo-textile over the angle fillet when the first coat in still wet, treatment of cracks completely as per specification. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Sqm | 1457.87 | 1457.87 | 606.0 | False | None | None | False | None | False | 883469.22 | 0 | 3342877 | 117456 | None | 10.1.7 | Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: PVC pipes 110mm dia., 6 kg/sqcm & class 3
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Rmtr | 514.32 | 514.32 | 54.0 | False | None | None | False | None | False | 27773.28 | 0 | 3342878 | 117456 | None | 11.16.2 | Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Kg | 183.95 | 183.95 | 945.0 | False | None | None | False | None | False | 173832.75 | 0 | 3342879 | 117456 | None | 18.1 | Providing and supplying aluminium extruded tubular and other alu- minium sections as per the architectural drawings and approved draw- ings of Chief Architect, GoK.The aluminium quality shall be as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. ( The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account).The weight of aluminium extruded section shall be taken for purpose of payment.
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Kg | 509.32 | 509.32 | 409.5 | False | None | None | False | None | False | 208566.54 | 0 | 3342880 | 117456 | None | 18.3 | Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface 2 of approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer. The IGUs shall be assembled in the factory workshop of the glass processor. (Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.18.2)For payment, only the actual area of glass on face 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in m2.(i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face 2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15, light reflection external 10 to 20 , shading coefficient (0.25-0.28) and U value of 3.0 to 3.3 W/ m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Sqm | 3807.98 | 3807.98 | 63.0 | False | None | None | False | None | False | 239902.74 | 0 | 3342881 | 117456 | None | 2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
LINTEL ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Cum | 13569.07 | 13569.07 | 13.27 | False | None | None | False | None | False | 180061.5589 | 0 |
| 1719297809000 | 0 | None | None | Buildings | SUMP TANK | 501803.5 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3342882 | 117457 | None | 2.5a | Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness.By Mechanical Means using Dozer.A In area of light jungle
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Sqm | 486.93 | 486.93 | 26.79 | False | None | None | False | None | False | 13044.8547 | 0 | 3342883 | 117457 | None | 1.14.1 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Cum | 126.38 | 126.38 | 55.46 | False | None | None | False | None | False | 7009.0348 | 0 | 3342884 | 117457 | None | 1.15.1 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In ordinary/soft rock without blasting upto 1.5 m depth
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Cum | 449.76 | 449.76 | 4.02 | False | None | None | False | None | False | 1808.0352 | 0 | 3342885 | 117457 | None | 1.15.2 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work Depth exceeding 1.5 m, but not exceeding 3 m
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Cum | 526.58 | 526.58 | 2.14 | False | None | None | False | None | False | 1126.8812 | 0 | 3342886 | 117457 | None | 1.A | Loading and Unloading of Stone Boulder/Stone aggregates/ Sand/Kankar/Moorum. (Disposal of 10Km)
For 5 KM lead = 2.5 x 1.28 x 5 + loading and Unloading charges =68 = 84.00/cum
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Cum | 167.27 | 167.27 | 50.0 | False | None | None | False | None | False | 8363.5 | 0 | 3342887 | 117457 | None | 1.9 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Cum | 329.57 | 329.57 | 11.39 | False | None | None | False | None | False | 3753.8023 | 0 | 3342888 | 117457 | None | 2.1.3 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Cum | 7420.37 | 7420.37 | 2.18 | False | None | None | False | None | False | 16176.4066 | 0 | 3342889 | 117457 | None | 2.2.2.1 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
RAFT ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Cum | 8703.13 | 8703.13 | 4.37 | False | None | None | False | None | False | 38032.6781 | 0 | 3342890 | 117457 | None | 2.2.2.1 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
WALLS ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Cum | 8864.3 | 8864.3 | 8.28 | False | None | None | False | None | False | 73396.404 | 0 | 3342891 | 117457 | None | 2.2.2.1 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
COVER SLAB ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Cum | 9670.15 | 9670.15 | 4.37 | False | None | None | False | None | False | 42258.5555 | 0 | 3342892 | 117457 | None | 11.32 | Providing Thermo-Mechanically Treated bars of grade Fe-550 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately)
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Tonne | 110837.22 | 110837.22 | 2.23 | False | None | None | False | None | False | 247167.0006 | 0 | 3342893 | 117457 | None | 15.1 | Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/ Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge.
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Sqm | 1012.26 | 1012.26 | 27.14 | False | None | None | False | None | False | 27472.7364 | 0 | 3342894 | 117457 | None | 8.3.1 | Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Sqm | 438.61 | 438.61 | 27.14 | False | None | None | False | None | False | 11903.8754 | 0 | 3342895 | 117457 | None | 8.4.1 | Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:3 (1 cement: 3 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Sqm | 400.2 | 400.2 | 5.52 | False | None | None | False | None | False | 2209.104 | 0 | 3342896 | 117457 | None | 8.40 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Sqm | 142.49 | 142.49 | 21.62 | False | None | None | False | None | False | 3080.6338 | 0 | 3342897 | 117457 | None | 624 | C. I Manhole covers with frame 610 * 455mm size (38kgs)
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | No | 2500.0 | 2500.0 | 2.0 | False | None | None | False | None | False | 5000.0 | 0 |
| 1719297809000 | 0 | None | None | Buildings | BORE WELL | 340568.33 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3342898 | 117458 | None | 4.0 | Geophysical investigation of site for sinking Borewell for supplying drinking water to Habitation either through the Handpump, MWS or PWSS by vertical electrical sounding by adopting veener or schlumbergers's method including reconassiance of survey of Geological formation, Geophysical investigation of existing ground water in the vicinity quality, quantity and acceptability of the user including the location of site,recommended department of casing pipe required to seal the top unconsolidated formation including an extra depth of 1.00Mtr in consolidated formation for proper seating of casing pipe, depth of drilling required to cover full depth of aquifer proposed to be tpped , probable yield and other infermation required including transportation of instrument and accessories to work site engaging technical personnel labour required etc complete as directed by Engineer in charge
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Each | 6066.38 | 6066.38 | 1.0 | False | None | None | False | None | False | 6066.38 | 0 | 3342899 | 117458 | None | 1.1 | Sinking of borewell of 165 mm dia clear using super fast hydraulic of capasity 300 PSIG & above 1100 CMF & above in all strata including over burden upto 20 M fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle crew charges and cost of consumables, etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes) for piped water supply schemes
0.00 TO 50 MTR ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Rmtr | 342.2 | 342.2 | 50.0 | False | None | None | False | None | False | 17110.0 | 0 | 3342900 | 117458 | None | 1.2 | Sinking of borewell of 165 mm dia clear using super fast hydraulic of capasity 300 PSIG & above 1100 CMF & above in all strata including over burden upto 20 M fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle crew charges and cost of consumables, etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes) for piped water supply schemes
50 TO 100 MTR ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Rmtr | 429.52 | 429.52 | 50.0 | False | None | None | False | None | False | 21476.0 | 0 | 3342901 | 117458 | None | 1.3 | Sinking of borewell of 165 mm dia clear using super fast hydraulic of capasity 300 PSIG & above 1100 CMF & above in all strata including over burden upto 20 M fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle crew charges and cost of consumables, etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes) for piped water supply schemes
100 TO 150 MTR ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Rmtr | 456.66 | 456.66 | 50.0 | False | None | None | False | None | False | 22833.0 | 0 | 3342902 | 117458 | None | 32.0 | Supply Supply of ISI mark 175mm nominal bore,plain and steel casing pipe grade of steel Fe 410 of wall thickness conforming to IS 4270-2001 and latest ammendments, electrical resistance welded steel tubes, material and conforming to IS 1387-1993 and manufactured by basic open hearth electric or basic oxygen process in random length of 5-7m both ends.threaded conforming to IS 554-1985 one end fixed with socket conforming to IS 4270-2001 and the other end with screwed pipes all shall be responsibaly free from defects. The tubes shall be responsible straight end should be with ISI marking weighing 25.10kg/m.prices include Collar-Medium duty.
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Rmtr | 2280.94 | 2280.94 | 25.0 | False | None | None | False | None | False | 57023.5 | 0 | 3342903 | 117458 | None | 34.00 | Supply and delivery at site 50mm(2”) dia heavy duty unplasticized PVC Column pipes with heavy duty collars,rubber profile ring,vibration control profile ring,freezing and turbulence free leak proof EPDM ring with ISI mark with its latest amendments
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Rmtr | 587.64 | 587.64 | 150.0 | False | None | None | False | None | False | 88146.0 | 0 | 3342904 | 117458 | None | 33.00 | Providing and fixing MS casing collars as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | No | 177.0 | 177.0 | 1.0 | False | None | None | False | None | False | 177.0 | 0 | 3342905 | 117458 | None | 34.00 | Providing and laying at site of work MS casing caps as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments including cost of material and labour charges for fixing, if any etc. complete with all lead and lifts and as directed by the Engineer in charge
177 ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | No | 193.52 | 193.52 | 1.0 | False | None | None | False | None | False | 193.52 | 0 | 3342906 | 117458 | None | 13.81.3 | Providing NP/CP 50mm dia Waste Unions conforming to ISI specifications and fixing them in position as per directions (Rates includes cost of materials fixtures and conveyance to work spot etc complete)
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | No | 247.8 | 247.8 | 1.0 | False | None | None | False | None | False | 247.8 | 0 | 3342907 | 117458 | None | 11.00 | Providing,supplying to work site, Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications,as per necessary ammendments and instructions of engineer incharge of work. For 5.00 HP - 90 LPM @ 110 m = 10 STG Outlet Dia - 2.00"" - etc., complete with all
lead & lift and work to be executed as per the specification and Engineer-in-charge of the work.
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | No | 42421.0 | 42421.0 | 1.0 | False | None | None | False | None | False | 42421.0 | 0 | 3342908 | 117458 | None | 29.1 | Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOL- Direct Online Starter 2) S-D- Star Delta Starter Up to 6 HP - etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work.
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | No | 11210.0 | 11210.0 | 1.0 | False | None | None | False | None | False | 11210.0 | 0 | 3342909 | 117458 | None | 35. | Supply and delivery at site 50mm(2”) dia heavy duty CI adopter set complete suitable for uPVC Column pipes for Submersible pumpsets. complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work.
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Set | 1947.0 | 1947.0 | 1.0 | False | None | None | False | None | False | 1947.0 | 0 | 3342910 | 117458 | None | 37.1 | Supply and delivery at site Stringing of heavy duty Naylone/PP rope with ISI etc complete suitable for Single phase Pumpsets.
- etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work.
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Job | 47.2 | 47.2 | 100.0 | False | None | None | False | None | False | 4720.0 | 0 | 3342911 | 117458 | None | 38. | Labour charges for Erection, Electrification and commissioning works of Pump sets including aligning and balancing with all necessary erection of materials and labour including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges, tools and equipments etc., involved in the job. as per specifications, with testing of as per instructions of engineer incharge of work - etc., complete with all lead & lift and work to be executed as per the specification and
Engineer-in-charge of the work. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Job | 7257.0 | 7257.0 | 1.0 | False | None | None | False | None | False | 7257.0 | 0 | 3342912 | 117458 | None | 40. | Labour charges for Erection of outdoor type panel board and meter board units with all necessary materials and labour tools and equipments including providing cement concrete foundation bed etc., complete. as per specifications, with testing of as per instructions of engineer incharge of work - etc., complete with all lead & lift and work to be executed as per the specification and
Engineer-in-charge of the work. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Job | 1593.0 | 1593.0 | 1.0 | False | None | None | False | None | False | 1593.0 | 0 | 3342913 | 117458 | None | 2.11.3 | Supplying and drawing 3 core flat PVC sheathed submersible pump cable manufactured with electrolytic grade copper with flexible copper with low resistance conductor confirmining to table 3 class 5 of IS:8130-1984 and virgin grade PVC insulation and sheathed suitable for working voltage upto 1100Volts as per IS-694:1990 & confirming to GTP of GROUP-A(12/2.10)
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Rmtr | 138.06 | 138.06 | 150.0 | False | None | None | False | None | False | 20709.0 | 0 | 3342914 | 117458 | None | 6.40.2 | Fabricating supplying and mounting MS box made out .SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete (49/6.40) 16SWG
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Sq CM | 0.51 | 0.51 | 30000.0 | False | None | None | False | None | False | 15300.0 | 0 | 3342915 | 117458 | None | 5.44.4 | Supply and Installation I Fixing I Provision of Outdoor type Thermoplastic Modular Panel enclosure with transparent Polycarbonate Lid, shock proof, IP65 (Weather Proof), rust proof, dust proof, water proof, corrosion proof having internally Embedded gasket on both lid and flap suitable to fix Single Phase I Three Phase Energy Meter in suitable base plate and having a provision for Fuse I MCB cutout with suitable transparent hinged flap opening for operating MCB along with 10 complete tamper proof SEALING facility. (50/6.42) 600mmx600mmx170mm.
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Each | 17133.6 | 17133.6 | 1.0 | False | None | None | False | None | False | 17133.6 | 0 | 3342916 | 117458 | None | 6.6.6 | Supplying and fixing polished wood board made of not less than 15mm thick plank on both sides with planks made out of not more than 2 pieces and fixing the same to the wall using tapered inverted wooden plugs screws etc. - 500 x 500 x 65 mm (20" x 20" x 2.5") etc., complete as per directions of the Engineer-in-charge
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Each | 384.83 | 384.83 | 1.0 | False | None | None | False | None | False | 384.83 | 0 | 3342917 | 117458 | None | 6.16.5 | Supplying and fixing miniature circuit breakers/Isolators on existing MCB distribution boards using necessary fixing materials and wiring complete as directed by the Engineer-in-charge - 5 to 30 Amps Triple and Neutral
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Each | 2023.7 | 2023.7 | 1.0 | False | None | None | False | None | False | 2023.7 | 0 | 3342918 | 117458 | None | 6.5.1 | Supplying and fixing TPST with neutral link switches rewirable fuse type - Havels / Standard / Indo-Asian Crescent - 30 to 35 Amps, etc., complete as per directions of the Engineer-in-charge
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Each | 2124.0 | 2124.0 | 1.0 | False | None | None | False | None | False | 2124.0 | 0 | 3342919 | 117458 | None | 6.35 | Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 volts grade, for power factor improvement of rotating machinery (48/6.35)
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Each | 472.0 | 472.0 | 1.0 | False | None | None | False | None | False | 472.0 | 0 |
| 1719297809000 | 0 | None | None | Buildings | WATER SUPPLY WORKS GF | 505655.79 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3342920 | 117459 | None | 13.50.5 | Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for
cold water supply including all uPVC plain & brass threaded fittings
This includes jointing of pipes & fittings with one step uPVC solvent
cement, trenching, refilling & testing of joints complete as per direction
of Engineer in Charge. External work
40mm dia pipes, From wash basin waste lines
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Rmtr | 376.66 | 376.66 | 25.0 | False | None | None | False | None | False | 9416.5 | 0 | 3342921 | 117459 | None | 13.50.6 | Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for
cold water supply including all uPVC plain & brass threaded fittings
This includes jointing of pipes & fittings with one step uPVC solvent
cement, trenching, refilling & testing of joints complete as per direction
of Engineer in Charge. External work
50mm dia pipes, From sink & urinal waste lines
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Rmtr | 478.25 | 478.25 | 10.0 | False | None | None | False | None | False | 4782.5 | 0 | 3342922 | 117459 | None | 13.64.1 | Providing and fixing Sewer (SWR) pipes, including all fittings, This
includes jointing of pipes & fittings with one step solvent cement,
trenching, refilling & testing of joints complete as per direction of
Engineer in Charge. ( Internal drainage)"
75mm nominal dia pipes ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Rmtr | 358.07 | 358.07 | 100.0 | False | None | None | False | None | False | 35807.0 | 0 | 3342923 | 117459 | None | 13.64.2 | Providing and fixing Sewer (SWR) pipes, including all fittings, This
includes jointing of pipes & fittings with one step solvent cement,
trenching, refilling & testing of joints complete as per direction of
Engineer in Charge. ( Internal drainage)"
110mm nominal dia pipes ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Rmtr | 477.02 | 477.02 | 55.0 | False | None | None | False | None | False | 26236.1 | 0 | 3342924 | 117459 | None | 13.48 | Providing and fixing on wall face unplasticised Rigid PVC rain water
pipes conforming to IS : 13592 Type A, including jointing with seal ring
conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i)
Single socketed pipes 100 mm diameter ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Rmtr | 360.55 | 360.55 | 100.0 | False | None | None | False | None | False | 36055.0 | 0 | 3342925 | 117459 | None | 13.63 | Providing and fixing PVC (S.W.R) Multi Floor Trap 10.0 cm X 7.5 cm X 5.0
cm X 4.0 cm with all fitting arrangements & all necessary accessories
complete ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Each | 302.32 | 302.32 | 20.0 | False | None | None | False | None | False | 6046.4 | 0 | 3342926 | 117459 | None | 14.31 | Providing and fixing 600x450 mm beveled edge mirror of superior glass
(of approved quality) complete with 6 mm thick hard board ground fixed
to wooden cleats with C.P. brass screws and washers complete. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Each | 1511.58 | 1511.58 | 9.0 | False | None | None | False | None | False | 13604.22 | 0 | 3342927 | 117459 | None | 13.9.2 | Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet :
150 mm diameter
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | No | 345.68 | 345.68 | 6.0 | False | None | None | False | None | False | 2074.08 | 0 | 3342928 | 117459 | None | 14.22B | Providing and fixing CP Brass 15 mm nominal dia Single lever telephonic
wall mixer of quality & make as approved by Engineer in charge."
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Each | 6891.32 | 6891.32 | 6.0 | False | None | None | False | None | False | 41347.92 | 0 | 3342929 | 117459 | None | 14.40.2 | Providing and fixing PTMT towel rail complete with brackets fixed to
wooden cleats with CP brass screws with concealed fittings arrangement
of approved quality and colour 600 mm long towel rail with total length of 645 mm, width 78 mm and
effective height of 88 mm, weighing not less than 190 g ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Each | 614.54 | 614.54 | 6.0 | False | None | None | False | None | False | 3687.24 | 0 | 3342930 | 117459 | None | 14.3.1 | Providing and fixing white vitreous china pedestal type water closet
(European type) with seat and lid, 10 litre low level white vitreous china
flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush
bend, overflow arrangement with specials of standard make and mosquito
proof coupling of approved municipal design complete, including
painting of fittings and brackets, cutting and making good the walls and
floors wherever required :: W.C. pan with ISI marked white solid plastic seat and lid ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Each | 7405.5 | 7405.5 | 10.0 | False | None | None | False | None | False | 74055.0 | 0 | 3342931 | 117459 | None | 14.10.1.1 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per
IS:13983 with C.I. brackets and stainless steel plug 40 mm, including
painting of fittings and brackets, cutting and making good the walls
wherever required : (510x1040 mm bowl depth 250 mm) ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Each | 6960.7 | 6960.7 | 1.0 | False | None | None | False | None | False | 6960.7 | 0 | 3342932 | 117459 | None | 14.7.1 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15mm C.P. brass pillar taps
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Each | 3818.6 | 3818.6 | 9.0 | False | None | None | False | None | False | 34367.4 | 0 | 3342933 | 117459 | None | 13.15 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931.
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | No | 898.28 | 898.28 | 26.0 | False | None | None | False | None | False | 23355.28 | 0 | 3342934 | 117459 | None | 13.32.1 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,
having thermal stability for hot & cold water supply, including all CPVC
plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00
m spacing. This includes jointing of pipes & fittings with one step CPVC
solvent cement and the cost of cutting chases and making good the
same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.
15 mm nominal dia Pipes
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Rmtr | 382.85 | 382.85 | 25.0 | False | None | None | False | None | False | 9571.25 | 0 | 3342935 | 117459 | None | 13.32.2 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,
having thermal stability for hot & cold water supply, including all CPVC
plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00
m spacing. This includes jointing of pipes & fittings with one step CPVC
solvent cement and the cost of cutting chases and making good the
same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.
20 mm nominal dia Pipes
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Rmtr | 469.58 | 469.58 | 180.0 | False | None | None | False | None | False | 84524.4 | 0 | 3342936 | 117459 | None | 13.32.3 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,
having thermal stability for hot & cold water supply, including all CPVC
plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00
m spacing. This includes jointing of pipes & fittings with one step CPVC
solvent cement and the cost of cutting chases and making good the
same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.
25 mm nominal dia Pipes
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Rmtr | 591.0 | 591.0 | 25.0 | False | None | None | False | None | False | 14775.0 | 0 | 3342937 | 117459 | None | 13.33 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,
having thermal stability for hot & cold water supply including all CPVC
plain & brass threaded fittings This includes jointing of pipes & fittings
with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work"
Shafts & Terrace
25 mm nominal dia Pipes ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Rmtr | 366.74 | 366.74 | 100.0 | False | None | None | False | None | False | 36674.0 | 0 | 3342938 | 117459 | None | 13.34 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank,IS:12701 marked,with cover and suitable locking arrangement and making necessary holes for inlet,outlet and overflow pipes but without fittings and the base support for tank.
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Ltr | 11.15 | 11.15 | 3500.0 | False | None | None | False | None | False | 39025.0 | 0 | 3342939 | 117459 | None | 13.5.2 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :"
25 mm nominal bore
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | No | 411.35 | 411.35 | 8.0 | False | None | None | False | None | False | 3290.8 | 0 |
| 1719297809000 | 0 | None | None | Buildings | WATER SUPPLY WORKS FF | 538096.14 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3342940 | 117460 | None | 13.50.5 | Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for
cold water supply including all uPVC plain & brass threaded fittings
This includes jointing of pipes & fittings with one step uPVC solvent
cement, trenching, refilling & testing of joints complete as per direction
of Engineer in Charge. External work
40mm dia pipes, From wash basin waste lines
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Rmtr | 380.42 | 380.42 | 20.0 | False | None | None | False | None | False | 7608.4 | 0 | 3342941 | 117460 | None | 13.50.6 | Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for
cold water supply including all uPVC plain & brass threaded fittings
This includes jointing of pipes & fittings with one step uPVC solvent
cement, trenching, refilling & testing of joints complete as per direction
of Engineer in Charge. External work
50MM DIA PIPES, FROM SINK & URINAL WASTE LINES ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Rmtr | 483.04 | 483.04 | 25.0 | False | None | None | False | None | False | 12076.0 | 0 | 3342942 | 117460 | None | 13.64.1 | Providing and fixing Sewer (SWR) pipes, including all fittings, This
includes jointing of pipes & fittings with one step solvent cement,
trenching, refilling & testing of joints complete as per direction of
Engineer in Charge. ( Internal drainage)
75mm nominal dia pipes ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Rmtr | 361.65 | 361.65 | 150.0 | False | None | None | False | None | False | 54247.5 | 0 | 3342943 | 117460 | None | 13.61.2 | Providing and fixing Sewer (SWR) pipes, including all fittings, This
includes jointing of pipes & fittings with one step solvent cement,
trenching, refilling & testing of joints complete as per direction of
Engineer in Charge. ( Internal drainage)
110mm nominal dia pipes ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Rmtr | 481.79 | 481.79 | 120.0 | False | None | None | False | None | False | 57814.8 | 0 | 3342944 | 117460 | None | 13.63 | Providing and fixing PVC (S.W.R) Multi Floor Trap 10.0 cm X 7.5 cm X 5.0
cm X 4.0 cm with all fitting arrangements & all necessary accessories
complete"
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Each | 305.34 | 305.34 | 32.0 | False | None | None | False | None | False | 9770.88 | 0 | 3342945 | 117460 | None | 14.31 | Providing and fixing 600x450 mm beveled edge mirror of superior glass
(of approved quality) complete with 6 mm thick hard board ground fixed
to wooden cleats with C.P. brass screws and washers complete. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Each | 1526.7 | 1526.7 | 13.0 | False | None | None | False | None | False | 19847.1 | 0 | 3342946 | 117460 | None | 13.9.2 | Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet :
150 mm diameter
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Each | 349.14 | 349.14 | 12.0 | False | None | None | False | None | False | 4189.68 | 0 | 3342947 | 117460 | None | 14.22B | Providing and fixing CP Brass 15 mm nominal dia Single lever telephonic
wall mixer of quality & make as approved by Engineer in charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Each | 6960.23 | 6960.23 | 12.0 | False | None | None | False | None | False | 83522.76 | 0 | 3342948 | 117460 | None | 14.40.2 | Providing and fixing PTMT towel rail complete with brackets fixed to
wooden cleats with CP brass screws with concealed fittings arrangement
of approved quality and colour 600 mm long towel rail with total length of 645 mm, width 78 mm and
effective height of 88 mm, weighing not less than 190 g ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Each | 620.69 | 620.69 | 12.0 | False | None | None | False | None | False | 7448.28 | 0 | 3342949 | 117460 | None | 14.3.1 | Providing and fixing white vitreous china pedestal type water closet
(European type) with seat and lid, 10 litre low level white vitreous china
flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush
bend, overflow arrangement with specials of standard make and mosquito
proof coupling of approved municipal design complete, including
painting of fittings and brackets, cutting and making good the walls and
floors wherever required :: W.C. pan with ISI marked white solid plastic seat and lid ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Each | 7479.56 | 7479.56 | 10.0 | False | None | None | False | None | False | 74795.6 | 0 | 3342950 | 117460 | None | 14.7.1 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15mm C.P. brass pillar taps
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Each | 3856.78 | 3856.78 | 13.0 | False | None | None | False | None | False | 50138.14 | 0 | 3342951 | 117460 | None | 13.15 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931.
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | No | 907.26 | 907.26 | 35.0 | False | None | None | False | None | False | 31754.1 | 0 | 3342952 | 117460 | None | 13.32 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,
having thermal stability for hot & cold water supply, including all CPVC
plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00
m spacing. This includes jointing of pipes & fittings with one step CPVC
solvent cement and the cost of cutting chases and making good the
same including testing of joints complete as per direction of Engineer in
Charge. Concealed work, including cutting chases and making good the
walls etc.
15 mm nominal dia Pipes
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Rmtr | 386.68 | 386.68 | 25.0 | False | None | None | False | None | False | 9667.0 | 0 | 3342953 | 117460 | None | 13.32.2 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,
having thermal stability for hot & cold water supply, including all CPVC
plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00
m spacing. This includes jointing of pipes & fittings with one step CPVC
solvent cement and the cost of cutting chases and making good the
same including testing of joints complete as per direction of Engineer in
Charge. Concealed work, including cutting chases and making good the
walls etc.
20 mm nominal dia Pipes
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Rmtr | 474.28 | 474.28 | 180.0 | False | None | None | False | None | False | 85370.4 | 0 | 3342954 | 117460 | None | 13.32.3 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,
having thermal stability for hot & cold water supply, including all CPVC
plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00
m spacing. This includes jointing of pipes & fittings with one step CPVC
solvent cement and the cost of cutting chases and making good the
same including testing of joints complete as per direction of Engineer in
Charge. Concealed work, including cutting chases and making good the
walls etc.
25 mm nominal dia Pipes
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Rmtr | 596.91 | 596.91 | 50.0 | False | None | None | False | None | False | 29845.5 | 0 |
| 1719297809000 | 0 | None | None | Buildings | WATER SUPPLY MR | 134520.0 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3342955 | 117461 | None | A.R | Supplying, installing, testing and commissioning approved make Submersible Pump made of C.I Construction suitable for building application. Thequoted rate shall also include for auto lvl.controller with cabling between hePumps, control panel, UGR & OHT etc.,. complete.approx. Length of cable = 80. providing necessary safety devices viz. dry run protection, over load relays etc., complete working on 230V, 50Hz, 1Ph, with starter,.(1 no. working and 1no. Standby ) Sump To OHT (DOMESTIC)2.00 HP
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | No | 41300.0 | 41300.0 | 2.0 | False | None | None | False | None | False | 82600.0 | 0 | 3342956 | 117461 | None | A.R | Supplying, fixing, testing and commissioning of CP health faucet Hand operated spray unit (instant type) CP Crutch etc., complete as directed by the Engineer in charge. ALD-577. (Jaguar make or Equalent)
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | No | 2183.0 | 2183.0 | 20.0 | False | None | None | False | None | False | 43660.0 | 0 | 3342957 | 117461 | None | A.R | Supplying, installing, testing and commissioning approved make water level controller (RMG or equivalent )for the Underground Sump and overhead tank. The quoted rate shall include for necessary wiring in PVC conduit between the control panel, underground sump and overhead tank. (length of cable approx. 150 mts.)
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | No | 8260.0 | 8260.0 | 1.0 | False | None | None | False | None | False | 8260.0 | 0 |
| 1719297809000 | 0 | None | None | Buildings | WATER SUPPLY EXTERNAL | 323004.12 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3342958 | 117462 | None | 1.5.1 | Earth work excavation by manual means for drains,canals, waste weir,
draft, approach channels, key trenches, foundation of bridges and
such simillar works in all kinds of soils , as per drawing and technical
specifications, including setting out, shoring, strutting, barricading,
caution lights, removal of stumps and other deleterious matter,
excavated surface leveled and sides neatly dressed disposing off the
excavated stuff or sorting & stacking the selected stuff for reuse in a
radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work."
In all kinds of soils Depth upto 1.5 m ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Cum | 370.46 | 370.46 | 68.0 | False | None | None | False | None | False | 25191.28 | 0 | 3342959 | 117462 | None | 1.9 | Filling approved earth (excluding rock) in trenches, plinth, sides of
foundations and other similar works etc. in layers not exceeding 20cm
in depth, consolidating each deposited layer by ramming and watering,
lead up to 50 m and lift upto 1.5 m. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Cum | 329.57 | 329.57 | 68.0 | False | None | None | False | None | False | 22410.76 | 0 | 3342960 | 117462 | None | 10.3.7 | Providing UPVC FOAM CORE pipes conforming to IS 16098 P-1 2013
with latest amendments ended with integral sockets with ISI mark and
conveying to worksite, rolling and lowering into trenches, laying true to
line and level and perfect linking at joints, testing and commissioning,
including loading and unloading at both destinations and cuts of pipes
wherever necessary including jointing of UPVC pipes (with cost of
elastomeric sealing rings) and specials (excluding cost of specials) with
jointing of approved type, with all labour, lead & lifts, including encasing
the pipes alround to a depth of not less than 15 cms. with soft gravel
or selected earth available from the excavation etc. complete and giving
necessary hydraulic test to the required pressure as per ISS (contractor
will make his own arrangements for procuring water for testing) etc.
complete. for Pipes of SN8 Self Fit - 160mm dia. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Rmtr | 764.46 | 764.46 | 150.0 | False | None | None | False | None | False | 114669.0 | 0 | 3342961 | 117462 | None | 16.9 | Constructing brick masonry chamber of internal dimension 600x600mm
and depth of 600mm (inner dimensions) with modular bricks of CD 75
in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering
12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Each | 6757.51 | 6757.51 | 20.0 | False | None | None | False | None | False | 135150.2 | 0 | 3342962 | 117462 | None | 13.39 | Providing and fixing square-mouth S.W. gully trap class SP-1 complete
with C.I. grating brick masonry chamber 150 x 100 mm size P type With
Non Modular common burnt clay bricks of designation 3.5 & with water
tight C.I. cover with frame of 300 x300 mm size (inside) the weight of
cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as
per standard design: ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Each | 3197.86 | 3197.86 | 8.0 | False | None | None | False | None | False | 25582.88 | 0 |
| 1719297809000 | 0 | None | None | Buildings | INTERNAL ELECTRICAL WORKS | 3012868.1 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3342963 | 117463 | None | 2.2.1 | Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each
outlet. Short point up to 3Mtr from tapping point to out let via switch ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Point | 333.29 | 333.29 | 27.0 | False | None | None | False | None | False | 8998.83 | 0 | 3342964 | 117463 | None | 2.2.2 | Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each
outlet. Medium point above 3Mtr up to 6Mtr from tapping point to out let via switch ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Point | 469.58 | 469.58 | 80.0 | False | None | None | False | None | False | 37566.4 | 0 | 3342965 | 117463 | None | 2.2.3 | Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each
outlet. Long point above 6Mtr up to 10Mtr from tapping point to out let via switch ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Point | 687.65 | 687.65 | 140.0 | False | None | None | False | None | False | 96271.0 | 0 | 3342966 | 117463 | None | 2.2.4 | Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each
outlet. Two outlet in a row, above 3Mtr up to 6Mtr from tapping point to out let via switches ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Point | 838.8 | 838.8 | 10.0 | False | None | None | False | None | False | 8388.0 | 0 | 3342967 | 117463 | None | 2.2.5 | Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each
outlet. Three outlet in a row, above 6Mts up to 10Mtr from tapping point to out let via switches ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Point | 1225.37 | 1225.37 | 5.0 | False | None | None | False | None | False | 6126.85 | 0 | 3342968 | 117463 | None | 3.4.1 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 1-2Way ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Each / BW | 170.98 | 170.98 | 20.0 | False | None | None | False | None | False | 3419.6 | 0 | 3342969 | 117463 | None | 3.4.2 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 3Way ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Each | 197.0 | 197.0 | 30.0 | False | None | None | False | None | False | 5910.0 | 0 | 3342970 | 117463 | None | 3.4.3 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 4-5Way ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Each | 219.3 | 219.3 | 28.0 | False | None | None | False | None | False | 6140.4 | 0 | 3342971 | 117463 | None | 3.4.4 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 6Way ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Each | 272.58 | 272.58 | 32.0 | False | None | None | False | None | False | 8722.56 | 0 | 3342972 | 117463 | None | 3.4.5 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 8 Way ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Each | 323.38 | 323.38 | 40.0 | False | None | None | False | None | False | 12935.2 | 0 | 3342973 | 117463 | None | 3.4.6 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 10-12Way ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Each | 395.24 | 395.24 | 40.0 | False | None | None | False | None | False | 15809.6 | 0 | 3342974 | 117463 | None | 3.5.1 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 1 to 2 Module ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Each | 169.74 | 169.74 | 20.0 | False | None | None | False | None | False | 3394.8 | 0 | 3342975 | 117463 | None | 3.5.1 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 3 Module
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Each | 199.48 | 199.48 | 30.0 | False | None | None | False | None | False | 5984.4 | 0 | 3342976 | 117463 | None | 3.5.2 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 4 Module
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Each | 216.83 | 216.83 | 28.0 | False | None | None | False | None | False | 6071.24 | 0 | 3342977 | 117463 | None | 3.5.3 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 6 Module
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Each | 289.93 | 289.93 | 32.0 | False | None | None | False | None | False | 9277.76 | 0 | 3342978 | 117463 | None | 3.5.4 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 8 Module
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Each | 351.88 | 351.88 | 40.0 | False | None | None | False | None | False | 14075.2 | 0 | 3342979 | 117463 | None | 3.5.5 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 10-12 Module
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Each | 426.22 | 426.22 | 40.0 | False | None | None | False | None | False | 17048.8 | 0 | 3342980 | 117463 | None | 3.6.1 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps one way Switch
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Each | 126.38 | 126.38 | 412.0 | False | None | None | False | None | False | 52068.56 | 0 | 3342981 | 117463 | None | 3.6.2 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps Two way Switch
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Each | 205.67 | 205.67 | 8.0 | False | None | None | False | None | False | 1645.36 | 0 | 3342982 | 117463 | None | 3.6.3 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps 3way socket
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Each | 211.87 | 211.87 | 150.0 | False | None | None | False | None | False | 31780.5 | 0 | 3342983 | 117463 | None | 3.6.4 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Stepped Fan Regulator.
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Each | 442.32 | 442.32 | 45.0 | False | None | None | False | None | False | 19904.4 | 0 | 3342984 | 117463 | None | 3.6.9 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 32Amps DP switch
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Each | 403.91 | 403.91 | 26.0 | False | None | None | False | None | False | 10501.66 | 0 | 3342985 | 117463 | None | 3.6.10 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6/16Amps universal socket
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Each | 292.4 | 292.4 | 26.0 | False | None | None | False | None | False | 7602.4 | 0 | 3342986 | 117463 | None | 1.13 | Supplyin and Fixing Metal Fan Box with Round Hook.
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | No | 144.96 | 144.96 | 45.0 | False | None | None | False | None | False | 6523.2 | 0 | 3342987 | 117463 | None | 1.2.1 | Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary. 19/20mm dia 2mm thick
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Rmtr | 81.77 | 81.77 | 1800.0 | False | None | None | False | None | False | 147186.0 | 0 | 3342988 | 117463 | None | 1.2.2 | Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary. 25mm dia 2mm thick
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Rmtr | 96.64 | 96.64 | 2000.0 | False | None | None | False | None | False | 193280.0 | 0 | 3342989 | 117463 | None | 1.2.3 | Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary. 32mm dia 2.5mm thick
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Rmtr | 127.62 | 127.62 | 500.0 | False | None | None | False | None | False | 63810.0 | 0 | 3342990 | 117463 | None | 1.3.1 | Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 19/20mm dia 2mm thick
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Rmtr | 84.25 | 84.25 | 900.0 | False | None | None | False | None | False | 75825.0 | 0 | 3342991 | 117463 | None | 1.3.2 | Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 25mm dia 2mm thick
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Rmtr | 97.88 | 97.88 | 1000.0 | False | None | None | False | None | False | 97880.0 | 0 | 3342992 | 117463 | None | 1.3.3 | Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 32mm dia 2.5mm thick
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Rmtr | 122.66 | 122.66 | 250.0 | False | None | None | False | None | False | 30665.0 | 0 | 3342993 | 117463 | None | 2.3.2 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest
amendments. 1.5 sqmm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Rmtr | 32.21 | 32.21 | 900.0 | False | None | None | False | None | False | 28989.0 | 0 | 3342994 | 117463 | None | 2.3.3 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest
amendments. 2.5 sqmm
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Rmtr | 52.04 | 52.04 | 2500.0 | False | None | None | False | None | False | 130100.0 | 0 | 3342995 | 117463 | None | 2.3.4 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest
amendments. 4 sqmm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Rmtr | 78.06 | 78.06 | 900.0 | False | None | None | False | None | False | 70254.0 | 0 | 3342996 | 117463 | None | 2.3.5 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest
amendments. 6 sqmm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Rmtr | 113.99 | 113.99 | 1200.0 | False | None | None | False | None | False | 136788.0 | 0 | 3342997 | 117463 | None | 5.19.11 | Supplying and fixing regular MCB distribution boards on wall wood board I flush mounting using required clamps, I bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure III Double Door 4 Way TP & N ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Each | 5003.08 | 5003.08 | 3.0 | False | None | None | False | None | False | 15009.24 | 0 | 3342998 | 117463 | None | 5.19.12 | Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure III - Double Door 6 Way TP & N ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Each | 6120.66 | 6120.66 | 3.0 | False | None | None | False | None | False | 18361.98 | 0 | 3342999 | 117463 | None | 5.18.1 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32Amps SP
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Each | 514.19 | 514.19 | 90.0 | False | None | None | False | None | False | 46277.1 | 0 | 3343000 | 117463 | None | 5.18.8 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 40Amps TPN
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Each | 3771.52 | 3771.52 | 3.0 | False | None | None | False | None | False | 11314.56 | 0 | 3343001 | 117463 | None | 5.18.9 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 50-63Amps TPN
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Each | 3826.03 | 3826.03 | 3.0 | False | None | None | False | None | False | 11478.09 | 0 | 3343002 | 117463 | None | 5.20.8 | Supplying, fixing and wiring Residual current Circuit Breaker [RCCB] 240/450V up to 300mA sensitivity on existing wood/panel board 32-40 Amps 4 pole
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Each | 6377.13 | 6377.13 | 12.0 | False | None | None | False | None | False | 76525.56 | 0 | 3343003 | 117463 | None | 32.05 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 4 core 16 sqmm
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Km | 109549.9 | 109549.9 | 0.1 | False | None | None | False | None | False | 10954.99 | 0 | 3343004 | 117463 | None | 32.09 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 3.5 core 35 sqmm
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Km | 190882.82 | 190882.82 | 0.1 | False | None | None | False | None | False | 19088.282 | 0 | 3343005 | 117463 | None | 32.13 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 3.5 core 70 sqmm
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Km | 393892.97 | 393892.97 | 0.15 | False | None | None | False | None | False | 59083.9455 | 0 | 3343006 | 117463 | None | 31.05 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 2.5 sqmm to 25 sqmm
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | K.Ltr | 25877.75 | 25877.75 | 0.2 | False | None | None | False | None | False | 5175.55 | 0 | 3343007 | 117463 | None | 31.06 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 35 sqmm to 95 sqmm
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Km | 38581.22 | 38581.22 | 0.15 | False | None | None | False | None | False | 5787.183 | 0 | 3343008 | 117463 | None | 6.11.3 | Supplying and fiixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) 32mm dia
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Each | 144.96 | 144.96 | 10.0 | False | None | None | False | None | False | 1449.6 | 0 | 3343009 | 117463 | None | 6.11.6 | Supplying and fiixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) 63mm dia
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Each | 480.73 | 480.73 | 12.0 | False | None | None | False | None | False | 5768.76 | 0 | 3343010 | 117463 | None | 6.17.6 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 16 sqmm
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Each | 15.41 | 15.41 | 16.0 | False | None | None | False | None | False | 246.56 | 0 | 3343011 | 117463 | None | 6.17.7 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 35 sqmm Long Barrel
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Each | 44.6 | 44.6 | 16.0 | False | None | None | False | None | False | 713.6 | 0 | 3343012 | 117463 | None | 6.17.10 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 70 sqmm Long Barrel
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Each | 148.68 | 148.68 | 16.0 | False | None | None | False | None | False | 2378.88 | 0 | 3343013 | 117463 | None | 12.56 | Supplying, fixing, wiring, earth electrode for grounding conduits, I.C.
cutouts and other equipment's on the meter board using 40 mm dia
2.90 mm thick GI pipe 2.5m long buried in a pit . The pit should be
filled with equal proportion of salt and charcoal 150 mm all-round the
pipe to complete depth. The connection from the pipe to the conduit
etc., is to be established through GI wire of size as per lSI specification
7.3.3. of IS 732 using 12 mm dia bolts, nuts, washers and check nuts
etc., the pipe shall have 16 through holes of 12 mm dia ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | No | 4348.89 | 4348.89 | 6.0 | False | None | None | False | None | False | 26093.34 | 0 | 3343014 | 117463 | None | 12.58.2 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x3mm GI strip
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Rmtr | 101.6 | 101.6 | 150.0 | False | None | None | False | None | False | 15240.0 | 0 | 3343015 | 117463 | None | 12.58.7 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x3mm GI strip 25x6mm Copper strip
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Rmtr | 706.23 | 706.23 | 120.0 | False | None | None | False | None | False | 84747.6 | 0 | 3343016 | 117463 | None | 12.58.11 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x3mm GI strip 600x600x3mm Copper plate
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Each | 9194.62 | 9194.62 | 8.0 | False | None | None | False | None | False | 73556.96 | 0 | 3343017 | 117463 | None | 11.5.2 | Supply of round/square recess/surface mounted rolling type LED Down light with. GU 10 LED Lamp Rib Fabricated from Die cast aluminum with white powder coated prewired to mains connector & has swiveling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50 60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 10-12W ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Each | 1096.52 | 1096.52 | 30.0 | False | None | None | False | None | False | 32895.6 | 0 | 3343018 | 117463 | None | 11.3.2 | Supplying of .feet - PVC Batten with integrated LED tube .W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fighting 1 x4'- 20/22 w ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Each | 854.91 | 854.91 | 100.0 | False | None | None | False | None | False | 85491.0 | 0 | 3343019 | 117463 | None | 11.11.7 | Supplying & fixing of retrofit type LED bulb.W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70%. efficacy 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 18 W 6500K ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Each | 527.81 | 527.81 | 20.0 | False | None | None | False | None | False | 10556.2 | 0 | 3343020 | 117463 | None | 11.11.5 | Supplying & fixing of retrofit type LED bulb.W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70%. efficacy 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 12 W, 6500K ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Each | 333.29 | 333.29 | 40.0 | False | None | None | False | None | False | 13331.6 | 0 | 3343021 | 117463 | None | 11.6.3 | Supplying of recess mounting non integral type. LED . W luminaire comprising of pressure decast/extruded aluminium housing, with spring loaded fase ceiling clamps, Power LEDs with CCT 6500-degree K, CRI 70%. efficacy 100 lumen per watt, 120degree beam spread, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level. LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, , THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. LED modular down light 2'x2' 34 36watt ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Each | 5641.17 | 5641.17 | 4.0 | False | None | None | False | None | False | 22564.68 | 0 | 3343022 | 117463 | None | 11.8.2 | Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with .W System Power consumption. LED Efficiency130lm/w, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Streetlight 40watts ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Each | 4985.74 | 4985.74 | 5.0 | False | None | None | False | None | False | 24928.7 | 0 | 3343023 | 117463 | None | 12.27 | Supplying & Fixing of Special Type pigmy and candle lamp. Operating voltage range from 180V to 265V, 50Hz AC power Supply
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | No | 64.43 | 64.43 | 23.0 | False | None | None | False | None | False | 1481.89 | 0 | 3343024 | 117463 | None | 6.1 | Supplying exhaust fan of 1440 RPM of 300mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply.
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Each | 1849.59 | 1849.59 | 15.0 | False | None | None | False | None | False | 27743.85 | 0 | 3343025 | 117463 | None | 6.4.1 | Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/19 and also comply with IS: 1709/1984 with latest amendment, Rated voltage 220 V/50 Hz, Rated power upto 35 W +/- 10 %, Rated current As per IS:374/19, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value 6.2 CMM / W, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201, as per IS specification, Motor winding. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 V, Insulation resistance Shall not be less than Two Mega Ohms (2M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, W& current, Air Delivery & Fan Speed as per IS:374/2019 with latest amendment, 2year manufacturer Warranty. (BLDC fans) 48" Sweep 5 Star (1200 mm) ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Each | 3316.8 | 3316.8 | 45.0 | False | None | None | False | None | False | 149256.0 | 0 | 3343026 | 117463 | None | 12.46 | Supplying & Fixing of 70-150 Watts lamp holder 2 Pin
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Each | 78.06 | 78.06 | 83.0 | False | None | None | False | None | False | 6478.98 | 0 | 3343027 | 117463 | None | 13.7.1 | Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall / ceiling / Rafter / Girders
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Each | 151.16 | 151.16 | 134.0 | False | None | None | False | None | False | 20255.44 | 0 | 3343028 | 117463 | None | 13.11 | Fixing a ceiling / wall mounting fan of all capacities and all types, with necessary clamps and 'S' hook made out of 15mm dia MS rod, with 5 amps. ceiling rose of approved quality with necessary length of 23 / 0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size
wooden board and wired.
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Each | 390.29 | 390.29 | 45.0 | False | None | None | False | None | False | 17563.05 | 0 | 3343029 | 117463 | None | 13.13 | Fixing one exhaust fan after making a suitable nitch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 amps, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame.
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Each | 875.97 | 875.97 | 15.0 | False | None | None | False | None | False | 13139.55 | 0 | 3343030 | 117463 | None | 13.4.1 | Supplying and fixing telescopic M.S. bracket fabricated by using 0.5m length 4” dia telescopic M. S. pipe, with 2” dia 1.5m long M. S. bracket and are welded with suitable angle, using 6mm thick M. S. sheet, grip bolts & nuts, as required, suitable for 9 to 12 Mtrs. M. S. tubular pole, with necessary two coats of painting, with all other accessories. Single bracket 1.5 Mtr. Length
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Each | 1810.18 | 1810.18 | 5.0 | False | None | None | False | None | False | 9050.9 | 0 | 3343031 | 117463 | None | 13.5 | Fixing halogen/metal halide / SVL / IL / LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires.
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Each | 200.72 | 200.72 | 5.0 | False | None | None | False | None | False | 1003.6 | 0 | 3343032 | 117463 | None | 5.42.2 | Fabricating supplying and mounting MS box made out .SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete 16SWG ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Sq CM | 0.53 | 0.53 | 500000.0 | False | None | None | False | None | False | 265000.0 | 0 | 3343033 | 117463 | None | 5.40.2 | Supplying .amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 250Amps 4x30x10mm Aluminum Strips
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Rmtr | 4255.97 | 4255.97 | 15.0 | False | None | None | False | None | False | 63839.55 | 0 | 3343034 | 117463 | None | 5.41.1 | Supplying and fixing angle iron frame work iabricated out of M.S. angle iron. and M.S. flat . with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 40x40x6mm
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Rmtr | 377.9 | 377.9 | 30.0 | False | None | None | False | None | False | 11337.0 | 0 | 3343035 | 117463 | None | 5.41.4 | Supplying and fixing angle iron frame work iabricated out of M.S. angle iron. and M.S. flat . with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 50x100x50x6mm C channel
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Rmtr | 936.68 | 936.68 | 30.0 | False | None | None | False | None | False | 28100.4 | 0 | 3343036 | 117463 | None | 5.15.10 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.FOUR POLE 125Amps 35kA
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Each | 12812.5 | 12812.5 | 1.0 | False | None | None | False | None | False | 12812.5 | 0 | 3343037 | 117463 | None | 5.14.9 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.FOUR POLE 100Amps 25kA
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Each | 10515.39 | 10515.39 | 4.0 | False | None | None | False | None | False | 42061.56 | 0 | 3343038 | 117463 | None | 5.18.9 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 50-63Amps TPN
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Each | 3826.03 | 3826.03 | 14.0 | False | None | None | False | None | False | 53564.42 | 0 | 3343039 | 117463 | None | 5.33 | Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH,KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Each | 11541.29 | 11541.29 | 1.0 | False | None | None | False | None | False | 11541.29 | 0 | 3343040 | 117463 | None | 5.38 | Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.C
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Each | 638.09 | 638.09 | 6.0 | False | None | None | False | None | False | 3828.54 | 0 | 3343041 | 117463 | None | 5.34 | Supplying, fixing and wiring 50/5 to 400/5Amps 5VA burden Current Transformer. Class 0.5 accuracy with Tape Wound
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Each | 696.32 | 696.32 | 3.0 | False | None | None | False | None | False | 2088.96 | 0 | 3343042 | 117463 | None | 5.51.4 | Supply and fixing of fully Enclosed 125A Automatic Transfer Switch (ATS) Pre-wired with Flexible Settings and seamless transfer between two power sources. The enclosure made of MS Power coated of necessary size. The switch comprising of EB/DG-Priority Source Selection,.Adjustable Time Delay(0.1sec to 3 hours),.Double-Break Contact System offering High Short-time Withstand (Icw),.with necessary Terminal Shrouds, Phase Barriers & Source Separator,. Protections for UV/OV, Phase Sequence, Single Phasing, Frequency variation. There should be sufficient space for cable termination. Three Phase 415 Volts
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Each | 91482.8 | 91482.8 | 1.0 | False | None | None | False | None | False | 91482.8 | 0 | 3343043 | 117463 | None | 5.39 | Supplying, fixing and wiring Automatic Power Factor controller fully, static units controlled by 14 stage microprocessor operation, relays LED display, self programming function for power stages and operating logic checking facility for healthy and efficient of each individual capacitor bank, measurement of network harmonics with indication when limit values are exceeded, Comprehensive displays with large, three place LED display, Long term memory for settings, protection for over voltage, power factor correction fault and no voltage, to connect I disconnect banks, with automatic recognition or with standard programs.
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Each | 26811.96 | 26811.96 | 1.0 | False | None | None | False | None | False | 26811.96 | 0 | 3343044 | 117463 | None | 5.37 | Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 volts grade, for power factor improvement of rotating machinery
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Kvar | 594.72 | 594.72 | 20.0 | False | None | None | False | None | False | 11894.4 | 0 | 3343045 | 117463 | None | 5.14.1 | Supply and fixing of 4pole power contactor with NO/NC contacts on existing wood/panel board using necessary bolts, nuts, washers and wiring etc., complete with AC-3 Rating and as per IS-13947. 25 Amps
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Each | 2738.19 | 2738.19 | 6.0 | False | None | None | False | None | False | 16429.14 | 0 | 3343046 | 117463 | None | 7.1.3 | Supplying.litres capacity vertical/horizontal type wall mounting Electrical water heater with 22 SWG copper/SS sheet metal inner Container tinned inside and anticorrosive paint outside and 20 SWG M.S. sheet metal outer cover filled with glass wool between inner and outer container for thermal insulation complete. The inlet and outlet pipes so arranged that water flow inside results in water to flow out from the inner container without turbulence. The Inner container shall have direct immersion type copper tube nickel plate. 2kW capacity element with a neon indicator fitted with 20A capacity 25 to 85 degree Centigrade range thermostat. The water heater shall completely be wired with 40/0.0076 inch 3 core copper flexible wire of 1.5 meters length and the outer container provided with heavy gauge brackets for wall mounting.
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Each | 12689.84 | 12689.84 | 6.0 | False | None | None | False | None | False | 76139.04 | 0 |
| 1719297809000 | 0 | None | None | Buildings | EXTERNAL ELECTRIFICATION AND D.G SET WORKS. | 2017757.1 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3343047 | 117464 | None | 1.01 | Supply RCC Pole - 9 Mtr Long, 145 Kg WL as per IS- 785
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Set | 8767.16 | 8767.16 | 2.0 | False | None | None | False | None | False | 17534.32 | 0 | 3343048 | 117464 | None | 2.02 | Erection of RCC Pole - 9 Mtr Long, 145 Kg WL as per IS- 785
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Set | 1379.01 | 1379.01 | 2.0 | False | None | None | False | None | False | 2758.02 | 0 | 3343049 | 117464 | None | 6.05 | Supply of 11 kV, 45 KN Polymeric Insulator ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | No | 107.79 | 107.79 | 6.0 | False | None | None | False | None | False | 646.74 | 0 | 3343050 | 117464 | None | 13.12 | Erection of 11 kV, 45 KN Polymeric Insulator
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | No | 59.47 | 59.47 | 6.0 | False | None | None | False | None | False | 356.82 | 0 | 3343051 | 117464 | None | 2.16 | Supply of Spiral Earth Electrode
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | No | 296.12 | 296.12 | 2.0 | False | None | None | False | None | False | 592.24 | 0 | 3343052 | 117464 | None | 2.16 | Erection of Spiral Earth Electrode
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | No | 115.23 | 115.23 | 2.0 | False | None | None | False | None | False | 230.46 | 0 | 3343053 | 117464 | None | 68.17 | Supply and fixing of Caution/Danger Board
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | No | 185.85 | 185.85 | 1.0 | False | None | None | False | None | False | 185.85 | 0 | 3343054 | 117464 | None | 4.02 | Supply of Anti Climbing Device (12 Mtr GI Barbed Wire
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Each | 110.27 | 110.27 | 2.0 | False | None | None | False | None | False | 220.54 | 0 | 3343055 | 117464 | None | 5.09 | Erection of Anti Climbing Device (12 Mtr GI Barbed Wire
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Each | 52.04 | 52.04 | 2.0 | False | None | None | False | None | False | 104.08 | 0 | 3343056 | 117464 | None | 24.05 | Supply and fixing of 11 kV, 400 Amps Double Break GOS
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Set | 26341.14 | 26341.14 | 1.0 | False | None | None | False | None | False | 26341.14 | 0 | 3343057 | 117464 | None | 24.07 | Supply and fixing of H-Frame for mounting GOS ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | No | 7521.97 | 7521.97 | 1.0 | False | None | None | False | None | False | 7521.97 | 0 | 3343058 | 117464 | None | 25.01 | Supply of DOLO Cut Out
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Set of 3 Nos | 7279.13 | 7279.13 | 1.0 | False | None | None | False | None | False | 7279.13 | 0 | 3343059 | 117464 | None | 13.01 | Erection of DOLO Cut Out
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Set of 3 Nos | 293.64 | 293.64 | 1.0 | False | None | None | False | None | False | 293.64 | 0 | 3343060 | 117464 | None | 13.07 | Supply, erection, testing and commissioning of 63 KVA 5Star rated Aluminium wound Distribution Transformer 11KV/433V with Off Load Tap Switch, Buchholtz relay winding temperature indicator, oil temperature indicator, , oil level indicator with + 5% to -10% Steps of 2.5%, HT and LT Cable Entry Box Type, stacked core with oil as per IS:1180(Part-1):2014 with all standard accessories as per latest IS standard No:2026/1977 and IS:335, technical specification & ESCOM approved.
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Each | 206940.08 | 206940.08 | 1.0 | False | None | None | False | None | False | 206940.08 | 0 | 3343061 | 117464 | None | 12.56 | Supplying, fixing, wiring, earth electrode for grounding conduits, I.C.
cutouts and other equipment's on the meter board using 40 mm dia
2.90 mm thick GI pipe 2.5m long buried in a pit . The pit should be
filled with equal proportion of salt and charcoal 150 mm all-round the
pipe to complete depth. The connection from the pipe to the conduit
etc., is to be established through GI wire of size as per lSI specification
7.3.3. of IS 732 using 12 mm dia bolts, nuts, washers and check nuts
etc., the pipe shall have 16 through holes of 12 mm dia ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Each | 4348.89 | 4348.89 | 10.0 | False | None | None | False | None | False | 43488.9 | 0 | 3343062 | 117464 | None | 12.58.3 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x6mm GI strip
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | MT | 158.59 | 158.59 | 100.0 | False | None | None | False | None | False | 15859.0 | 0 | 3343063 | 117464 | None | 12.58.9 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 40x6mm Copper strip
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Rmtr | 2035.68 | 2035.68 | 100.0 | False | None | None | False | None | False | 203568.0 | 0 | 3343064 | 117464 | None | 12.58.11 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 600x600x3mm Copper plate
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Each | 9194.62 | 9194.62 | 10.0 | False | None | None | False | None | False | 91946.2 | 0 | 3343065 | 117464 | None | 45.07 | Supply & Making of 11KV (E) Extruded "X" linked for tubing & moulded & cross-linked components using Heat Shrink Stress Control tube having High Permittivity XLPE Terminations - INDOOR & OUTDOOR JOINTING KIT & confirming to the GTP. 3x95Sqmm.Outdoor
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Set | 5039.01 | 5039.01 | 4.0 | False | None | None | False | None | False | 20156.04 | 0 | 3343066 | 117464 | None | 45.04 | Supply & Making of 11KV (E) Extruded "X" linked for tubing & moulded & cross-linked components using Heat Shrink Stress Control tube having High Permittivity XLPE Terminations - INDOOR & OUTDOOR JOINTING KIT & confirming to the GTP. 3x95Sqmm.Indoor ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Set | 3887.98 | 3887.98 | 2.0 | False | None | None | False | None | False | 7775.96 | 0 | 3343067 | 117464 | None | 36.01 | 11 kV, 3 Core, XPLE HTUG Cable with pressure extruded inner sheeth, ROUND
WIRE ARMOURED as per IS-7098 (Part-2) Armouring wires dia and Resistivity as per IS-3975. 95 Sqmm, (54 GI Wires - 2.5 mm Dia) ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Km | 1102296.17 | 1102296.17 | 0.3 | False | None | None | False | None | False | 330688.851 | 0 | 3343068 | 117464 | None | 38. | Providing chain link fencing 50 mm size of 8 guage properly stretched between
rectangular Poles and fixed with suitable bolts & nuts, the free ends shall be
welded to the Pole and block pipe at top and bottom as required including cost
of all materials, labour, lead and lifts, cutting, bending wherever necessary,
wastage and lapping etc., complete as per the direction of the engineer
incharge for work including two coats of approved quality paint over one coat of primer paint. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Sqm | 1222.89 | 1222.89 | 150.0 | False | None | None | False | None | False | 183433.5 | 0 | 3343069 | 117464 | None | 5.42.2 | Fabricating supplying and mounting MS box made out .SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete 16SWG ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Sq CM | 0.53 | 0.53 | 176000.0 | False | None | None | False | None | False | 93280.0 | 0 | 3343070 | 117464 | None | 5.40.2 | Supplying .amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 250Amps 4x30x10mm Aluminum Strips
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Rmtr | 4255.97 | 4255.97 | 6.0 | False | None | None | False | None | False | 25535.82 | 0 | 3343071 | 117464 | None | 5.41.1 | Supplying and fixing angle iron frame work iabricated out of M.S. angle iron. and M.S. flat . with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 40x40x6mm
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Rmtr | 377.9 | 377.9 | 12.0 | False | None | None | False | None | False | 4534.8 | 0 | 3343072 | 117464 | None | 5.41.4 | Supplying and fixing angle iron frame work iabricated out of M.S. angle iron. and M.S. flat . with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 50x100x50x6mm C channel
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Rmtr | 936.68 | 936.68 | 12.0 | False | None | None | False | None | False | 11240.16 | 0 | 3343073 | 117464 | None | 5.15.10 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.FOUR POLE 125Amps 35kA
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Each | 12812.5 | 12812.5 | 1.0 | False | None | None | False | None | False | 12812.5 | 0 | 3343074 | 117464 | None | 5.38 | Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.C
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Each | 638.09 | 638.09 | 3.0 | False | None | None | False | None | False | 1914.27 | 0 | 3343075 | 117464 | None | 10.1.3 | Supplying, installing, testing and commissioning of 25KVA/20kw Diesel Generator set(CPCB-4) with following specifications. Power rating as per standard reference condition as per-BS 5514 / ISO 3046 / ISO 8528 & IS 1002 / ISO 3046 Generator set specificationsEngine: Diesel generating set are rated at 1500RPM and conform to ISO 8528 specifications. The engines are radiator cooled, four stroke and multi cylinder, conforming to ISO 3046. The scope of supply includes: Electrical starter motor 12V DC Battery charging alternator, Bosch fuel system with mechanical governor, A1 Class. Spin-on lube oil filter, Spin-on dual fuel filter with water separator, Turbocharger, Charge air cooler, Silencer (Hospital grade),Dry type air cleaner, Shutoff coil, Flywheel and flywheel housing, First fill of lube oil and coolant, Safety for low lube oil pressure, Safety for high water temperature, Permissible overload of 10% for one hour in 12 hours of operation Capacity of Fuel Tank: Fuel tank suitable for 8 hours of operation 415 Volts, 0.8 pf (lag) suitable for 50 Hz, 3 phase, 4 wire systems, conforming toIS/IEC 60034-1. The Alternator is brushless type, screen protected, revolving field, self excited, self regulated through an AVR. The alternator shall have +
1.0 % Voltage regulation (max) in static conditions- IP: 23 protections with insulation class H. Mounting arrangement: Engine and alternator are mounted on a common MS fabricated base frame with AVM pads. Control Panel: The control panel is manufactured with 14/16 gauge CRCA sheet and is powder coated for weather-proof and long lasting finish. The control panel consists of the following parts:- PS0500 Controller, Aluminium bus bars with suitable capacity within/outgoing terminals, Indicating
lamps for ‘Load On’ and ‘Set Running’, Instrument fuses duly wired and ferruled, MCCB of suitable rating with overload and short circuit protections. Genset Controller: microprocessor based generator set monitoring and control system. The control provides a simple operator interface to the generator set, manual and remote start/ stop control, shutdown fault indication, and an LCD hour counter. The integration of all functions into a single control system provides enhanced reliability and performance compared to conventional generator set control systems. This control has been designed and tested to meet harsh environment in which gensets are typically applied. Features, Functions, protections 16 character x 2 line alphanumeric LCD display with LED Backlight. Operator interface, Provide a record of most recent fault conditions. Fault history stored in the control non volatile memory, Provide Alternator Data. Voltage (1 ph or 3 ph line to line and line to neutral voltage, Current (1 ph or 3 ph), kVA (3 ph and total), Frequency, Provide Engine Data, Starting
battery voltage, Engine running hours, Engine Temp, Engine oil pressure, Control includes provision for Service adjustment and calibration of DG control functions, Voltage, frequency selection, Configurable input and output set up, Meter calibration, Engine controls, Power Start operates on 12 VDC batteries,- Auto start mode accepts a ground signal from remote devices to automatically start the DG set. The remote start will also wake up the control system from sleep mode. Acoustic enclosure: The acoustic enclosure shall be made of 1.6 mm thick CRCA sheets in suitable approved shade and a structural/ sheet metal base frame painted in black. The walls of the enclosure are insulated with fire retardant foam so as to comply with the 75dBA at 1 mtr sound levels specified by Ministry of Environment & Forest. The enclosure has the following features: Specially designed to meet stringent MOEF/ CPCB norms of 75dBA @ 1mtr
at 75% load under free field conditions, Two point lifting for easy handling at customer site, Designed to have optimum serviceability, Air inlet louvers specially designed to operate at ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Set | 558914.14 | 558914.14 | 1.0 | False | None | None | False | None | False | 558914.14 | 0 | 3343076 | 117464 | None | 10.2.2 | Supply, Erection, testing and commissioning of AMF panel suitable for .KVA DG set. The panel is of cubical type base/floor mounting control panel with hinged doors, undrilled bottom gland plate, aluminium Bus Bar with the
accommodation for .amps 4 pole contactor for alternator with thermal O/L relay,. Amps 4 pole contactor for mains, HRC fuse for short circuit protection, Microprocessor based AMF module with supply failure timer, Restoration timer, 3 impulse automatic engine start/stop logic, Mains/generator voltage, .capacity bypass switch and frequency sensing, PCC 1301 controller with water temperature/Lube oil pressure/ engine speed, Voltage/ampere/Frequency/ KVA, Running-hour count, No of starts, Fault indication, over / under speed, Fails to start, Low oil pleasure, High engine temperature, Under/over voltage, over current, Earth fault relay, with indications for Mains on, Load on Mains, Battery charger on Push buttons AMf module by pass Mode, Battery charger unit with inbuilt Auto/Manual and flat/Boost facility. 25 KVA ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Each | 72742.93 | 72742.93 | 1.0 | False | None | None | False | None | False | 72742.93 | 0 | 3343077 | 117464 | None | A.R | Supply & installation of exhaust gas piping of suitable diameter as per manufactures standard welded black MS, B class pipe confirming to IS:3589 cut to required lengths and installed with necessary bends, supports and clamps, anti- vibration mountings, insulation of exhaust system with mineral wool / Rockwool, 50mm thick wire mesh & aluminum cladding etc.
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Rmtr | 2500.0 | 2500.0 | 10.0 | False | None | None | False | None | False | 25000.0 | 0 | 3343078 | 117464 | None | 2.5.7 | SupplyinganddrawingFlexibleMulticoreCablemanufacturedwithelectrolyticgradeflexiblecopperwithlowconductorconfirmingtoIS8130-1984and(Virgin)PVC insulations heated suitable for working voltage upto 1100 Volts as per IS-694:1990 2C x 2.5 mm2
---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Rmtr | 101.6 | 101.6 | 100.0 | False | None | None | False | None | False | 10160.0 | 0 | 3343079 | 117464 | None | 2.5.11 | SupplyinganddrawingFlexibleMulticoreCablemanufacturedwithelectrolyticgradeflexiblecopperwithlowconductorconfirmingtoIS8130-1984and(Virgin)PVCinsulationsheathedsuitableforworking voltage upto 1100 Volts as per IS-694:1990 6C x 2.5 mm2 ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | Rmtr | 337.01 | 337.01 | 100.0 | False | None | None | False | None | False | 33701.0 | 0 |
|
|
---|