createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1719303091384
version3
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee1710.00
emd170000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose02-07-2024 16:00:00
tenderQueryClose28-06-2024 11:00:00
technicalBidOpen03-07-2024 16:30:00
publishedDate25-06-2024 13:55:17
publishedByPostRDPR_EE_DIV_KPL
publishedByUserKPE15445 - H SATHYAPPA
bidValidityPeriod90
noOfCalls1
preBidMeetingDateNone
preBidMeetingYnFalse
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonEE PRE DIVISION KOPPAL
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumber08539220845
mobileNumberNone
tenderSupplierListNone
tenderSchedule
createdTs1719303091428
version6
createdDateNone
modifiedDateNone
tenderNumberRDPR/2024-25/BD/WORK_INDENT6365
titleRepairs of Room and Electrification at Somasagar School Const of Building Repairs of Electrification Water Tank at Basarihal Village Repairs of Room at Jiral Village Const of Room at Kanakapur Village Providing Water Supply and Repairs of Room at College at Kanakagiri Providing and Fixing of RO Plant at Const of Toilet at KPS at Kanakagiri and Const of Room at Hulihyder Village of Kanakagiri Taluka
descriptionRepairs of Room and Electrification at Somasagar School Const of Building Repairs of Electrification Water Tank at Basarihal Village Repairs of Room at Jiral Village Const of Room at Kanakapur Village Providing Water Supply and Repairs of Room at College at Kanakagiri Providing and Fixing of RO Plant at Const of Toilet at KPS at Kanakagiri and Const of Room at Hulihyder Village of Kanakagiri Taluka
categoryWORKS
categoryTextWorks
ecv6811702.19
deptNameRural Development and Panchayat Raj Department
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnTrue
location948
locationNameRDPR Division Office Koppal
provisionalAmount8124000.0
groupOverheadTotalNone
fileNumberEE/PRED/KPL/KKRDB/KNK/PACKAGE/13
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17193030910000NoneNoneBuildingsRepairs of Room and Electrification at Somasagar School210648.51
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3345088117551None15.23Providing and Applying PU based Elastomeric Liquid Applied PU Waterproofing Membrane single component, cold applied, water based acrylic PU dispersion with highly elastic and UV resistant water proofing treatment to the Existing Roof surface/Chajjas/Sunken portion of WC:Bathroom applied @ 1.2 l/per m2, having tensile strength greater than 1.5N/mm2, elongation greater than 300% with solid content not less than 60% in 2 coats including surface preparation, priming the surface with water based acrylic primer @0.1 l/m2, and spreading 60 gsm geotextile between two top coats completely as per specification. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification.Sqm773.85773.8581.0FalseNoneNoneFalseNoneFalse62681.850
3345089117551None8.33.1Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Special primer applied @ 0.75 ltr /10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-chargeSqm165.9165.984.0FalseNoneNoneFalseNoneFalse13935.60
3345090117551None19.22Dismantling tile work in floors and roofs laid in cement mortar including stacking material to the appropriate disposal area as per direction of Engineer-in-chargeCum50.450.448.0FalseNoneNoneFalseNoneFalse2419.20
3345091117551None2.1.1Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required t complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:4:8( M7.5) Using 40 mm nominal size graded crushed coarse aggregates Cum5947.25947.24.8FalseNoneNoneFalseNoneFalse28546.560
3345092117551None9.12.2Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grou ting the joints with white cement and matching pigments etc., complete. (Size of Tile 600x600 mm)Sqm1202.251202.2550.8FalseNoneNoneFalseNoneFalse61074.30
3345093117551None1.1.1SupplyingheavygaugePVCconduitpipe.dia.mmthickconfirmingtoIS2509withsuitablesizebends,junctionboxes,adhesivepasteetc,andfixingusinginvertedwoodplugsincaseofRCCceilingandRCCwall/stonestructureorrawlplugsincaseofbrickwallsandcementplasteringthedamagedportionusingheavygauge saddles at an interval of 700mm using NF screws.Rmtr69.069.050.0FalseNoneNoneFalseNoneFalse3450.00
3345094117551None1.1.1Supplying and fixing sheet Metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc 75 x 75 x 65 mmNo106.0106.06.0FalseNoneNoneFalseNoneFalse636.00
3345095117551None2.2.1Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point upto 3Mtr from tapping point to out let via switch boxNo285.0285.010.0FalseNoneNoneFalseNoneFalse2850.00
3345096117551None2.2.1Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch boxNo394.0394.05.0FalseNoneNoneFalseNoneFalse1970.00
3345097117551None2.2.2Long point above 6Mtr upto 10Mtr from tapping point to out let via switch boxNo555.0555.05.0FalseNoneNoneFalseNoneFalse2775.00
3345098117551None3.8Supplying 4mm thick plastic sheet with necessary nitches for fixing switches, regulators etc, and fixing on existing wooden or metal box using N.F. screwsSqm0.410.41500.0FalseNoneNoneFalseNoneFalse205.00
3345099117551None3.1.2Supplying 6A flush type socket and 6 A flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3854 6A 3/5 WayEach147.0147.020.0FalseNoneNoneFalseNoneFalse2940.00
3345100117551None6.3.1Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system 48" Sweep (1200 mm) Regular modeNo1900.01900.08.0FalseNoneNoneFalseNoneFalse15200.00
3345101117551None11.13Supplying and fixing of slim patty fitting, made out of CRCA Sheet metal body with locking type holder completely wired. Excluding Ballast & Fluorescent Tube.No361.0361.015.0FalseNoneNoneFalseNoneFalse5415.00
3345102117551None2.3.2Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 1.5 mmm26.026.050.0FalseNoneNoneFalseNoneFalse1300.00
3345103117551None2.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 2.5 mm2m42.042.050.0FalseNoneNoneFalseNoneFalse2100.00
3345104117551None2.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 4 mm2m63.063.050.0FalseNoneNoneFalseNoneFalse3150.00
17193030910000NoneNoneBuildingsConst of Building Repairs of Electrification Water Tank at Basarihal Village1573227.1
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3345105117552None1.4Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work.Cum254.1254.141.513FalseNoneNoneFalseNoneFalse10548.45330
3345106117552None2.1.1Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates work as per technical specificationsCum5947.25947.212.72FalseNoneNoneFalseNoneFalse75648.3840
3345107117552None5.2Providing Coursed rubble masonry (first sort) with hard stone in foundation and plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)Cum6948.96948.911.31FalseNoneNoneFalseNoneFalse78592.0590
3345108117552None5.3Providing Coursed rubble masonry (second sort) with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sandCum6515.256515.258.11FalseNoneNoneFalseNoneFalse52838.67750
3345109117552None5.4Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)Cum6708.456708.4512.3FalseNoneNoneFalseNoneFalse82513.9350
3345110117552None1.9Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum279.3279.345.9FalseNoneNoneFalseNoneFalse12819.870
3345111117552None2.2.1Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum6601.356601.3526.33FalseNoneNoneFalseNoneFalse173813.54550
3345112117552None2.5.1Providing and removing centring shuttering propping etc and removal of form work for foundation appendix I percentage on finished rate of concrete per cumSqm330.07330.071.73FalseNoneNoneFalseNoneFalse571.02110
3345113117552None2.5.1Providing and removing centring shuttering propping etc and removal of form work for foundation appendix I percentage on finished rate of concrete per cumSqm660.14660.142.73FalseNoneNoneFalseNoneFalse1802.18220
3345114117552None2.5.1Providing and removing centring shuttering propping etc and removal of form work for foundation appendix I percentage on finished rate of concrete per cumSqm3960.813960.815.76FalseNoneNoneFalseNoneFalse22814.26560
3345115117552None2.5.1Providing and removing centring shuttering propping etc and removal of form work for foundation appendix I percentage on finished rate of concrete per cumSqm3300.683300.6813.1FalseNoneNoneFalseNoneFalse43238.9080
3345116117552None2.11Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Tonne93929.8593929.852.75FalseNoneNoneFalseNoneFalse258307.08750
3345117117552None6.7Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.Cum8621.558621.5519.64FalseNoneNoneFalseNoneFalse169327.2420
3345118117552None11.34BProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc.Sqm192.15192.15177.66FalseNoneNoneFalseNoneFalse34137.3690
3345119117552None8.6.1Providing 12 mm cement plaster with Cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerin-charge.Sqm339.15339.1584.78FalseNoneNoneFalseNoneFalse28753.1370
3345120117552None8.7Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-chargeSqm279.3279.3115.38FalseNoneNoneFalseNoneFalse32225.6340
3345121117552None8.33.1Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 L/10 m² over and including one coat of Special primer applied @ 0.75 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (The gloss should be 50% @ 60 degree angle with 10 years life)Sqm165.9165.984.78FalseNoneNoneFalseNoneFalse14065.0020
3345122117552None8.29Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 L/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm297.15297.15115.38FalseNoneNoneFalseNoneFalse34285.1670
3345123117552None9.12.2Providing and laying vitrified floor tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mmSqm1202.251202.2557.8FalseNoneNoneFalseNoneFalse69490.050
3345124117552None9.34Flooring with 25mm thick polished tandur blue stone slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab, , including cost of materials, labour, curing, polishing complete as per specificationsSqm1622.251622.2518.7FalseNoneNoneFalseNoneFalse30336.0750
3345125117552None12.12Providing Mathi/Nandi wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications. Cum130412.1130412.10.24FalseNoneNoneFalseNoneFalse31298.9040
3345126117552None12.15Providing and fixing in position fully panelled Honne wood shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. ( excluding cost of fixtures )Sqm7816.27816.28.28FalseNoneNoneFalseNoneFalse64718.1360
3345127117552None8.49Lettering with black Japan paint of approved brand and manufacture to give an even shade including preparing the surface after thoroughly cleaning the surface to remove all dirt, dust and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-chargeNo4.24.27000.0FalseNoneNoneFalseNoneFalse29400.00
3345128117552None88.84Providing Wall black in 12 mm thick with CM 1:3 and applied with primer and two coats of acyrlic emulsion black paint including finishing etc completeSqm498.75498.753.6FalseNoneNoneFalseNoneFalse1795.50
3345129117552None12.80Providing and Fixing door latch with necessary screws etc completeSqm299.25299.253.6FalseNoneNoneFalseNoneFalse1077.30
3345130117552None20.27.3Providing and Fixing bright finished brass flush bolts with necessary brass screws etc cpmpleteEach172.2172.222.0FalseNoneNoneFalseNoneFalse3788.40
3345131117552None1.1.1Electrification:Supplying heavy gauge PVC conduit pipe . dia . mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws.19/20 mm dia 2 mm thickMtr69.069.040.0FalseNoneNoneFalseNoneFalse2760.00
3345132117552None1.4.1Supplying and fixing sheet Metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc 75 x 75 x 65 mmNos106.0106.08.0FalseNoneNoneFalseNoneFalse848.00
3345133117552None2.2.1Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Short point upto 3Mtr from tapping point to out let via switch boxNos285.0285.08.0FalseNoneNoneFalseNoneFalse2280.00
3345134117552None2.2.3Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch boxNos394.0394.08.0FalseNoneNoneFalseNoneFalse3152.00
3345135117552None2.2.3Long point above 6Mtr upto 10Mtr from tapping point to out let via switch boxNos555.0555.08.0FalseNoneNoneFalseNoneFalse4440.00
3345136117552None3.8Supplying 4mm thick plastic sheet with necessary nitches for fixing switches, regulators etc, and fixing on existing wooden or metal box using N.F. screws.Sqm0.410.411500.0FalseNoneNoneFalseNoneFalse615.00
3345137117552None3.1.2Supplying 6A flush type socket and 6 A flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3854 6A 3/5 WayNos147.0147.032.0FalseNoneNoneFalseNoneFalse4704.00
3345138117552None12.60Supplying & Fixing Chemical earthling for grounding. Conduits, IC cut-outs & other equipments backfill compound which is noncorrosive, thermally conductive, potential to permissible limits, superior Fault conduction capacity, non toxic, weather resistance & capable of achieving ohmic value less than one ohm Using 4ft. Copper bonded rod with backfill compoundNos4528.04528.01.0FalseNoneNoneFalseNoneFalse4528.00
3345139117552None6.3Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing systemNos1900.01900.04.0FalseNoneNoneFalseNoneFalse7600.00
3345140117552None11.14.2Supplying and fixing of slim box fitting, made out of CRCA Sheet metal body with locking type holder completely wired. Excluding Ballast & Fluorescent Tube 1 x 4' Tube light fittingNos361.0361.06.0FalseNoneNoneFalseNoneFalse2166.00
3345141117552None13.1.1Supplying and Fixing of.mm dia class A GI pipe bracket upto 2 ms long bent at suitable angle and fixing to this bracket street light fitting of all capacities to GI or GI or rail or RCC pole / wall using suitable clamps, bolts, and nuts and wiring using suitable capacity wires Using 25mm dia G.I.PipeNos978.0978.01.0FalseNoneNoneFalseNoneFalse978.00
3345142117552NoneP No 23Pre - Paid Energy Meter Single Phase, 5-30 Amps, 1.0 Accuracy Class with Key Pad Technology consumer interface unit along with pillfer proof boxNo7170.07170.01.0FalseNoneNoneFalseNoneFalse7170.00
3345143117552NoneP No 6Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 1.5 mmMtr26.026.040.0FalseNoneNoneFalseNoneFalse1040.00
3345144117552NoneP No 6Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 2.5 mmMtr42.042.040.0FalseNoneNoneFalseNoneFalse1680.00
3345145117552NoneP No 6Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:20104 mm2Mtr63.063.040.0FalseNoneNoneFalseNoneFalse2520.00
3345146117552NoneBasic RateRO Water Plant for Hemodialysis 500 Ltrs/Hr Capacity Specifications Plant capacity (Ltrs/Hr) 500 Plant type Microprocessor/microcontroller controlled single stage RO water system ( Feed water TDS more than 500 PPM) System type Online ,Offline Double raw water pump ( one active and the other stand by) No Raw water feed pump capacity (LPH) 1500 Micron particle filter after activated Carbon filter for removing suspended particles more than micron size 5 Distribution of RO plant water sufficient for number of dialysis machines 5-10 Material of Booster pump (offline) Stainless Steel 316No159000.0159000.01.0FalseNoneNoneFalseNoneFalse159000.00
3345147117552None1.6.1Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work.No508.2508.213.5FalseNoneNoneFalseNoneFalse6860.70
3345148117552None9.1.1Providing, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc. complete. NOTE: Upto 110mm dia Coil shall be used. For :HDPE PE 80 PN 6.0 HDPE Grade PE80-PN6.0, 63mm diaRmtr198.45198.4513.5FalseNoneNoneFalseNoneFalse2679.0750
17193030910000NoneNoneBuildingsRepairs of Room at Jiral Village348863.64
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3345149117553None15.23Providing and Applying PU based Elastomeric Liquid Applied PU Waterproofing Membrane single component, cold applied, water based acrylic PU dispersion with highly elastic and UV resistant water proofing treatment to the Existing Roof surface/Chajjas/Sunken portion of WC:Bathroom applied @ 1.2 l/per m2, having tensile strength greater than 1.5N/mm2, elongation greater than 300% with solid content not less than 60% in 2 coats including surface preparation, priming the surface with water based acrylic primer @0.1 l/m2, and spreading 60 gsm geotextile between two top coats completely as per specification. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification.Sqm773.85773.85144.0FalseNoneNoneFalseNoneFalse111434.40
3345150117553None8.33.1Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Special primer applied @ 0.75 ltr /10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-chargeSqm165.9165.9336.0FalseNoneNoneFalseNoneFalse55742.40
3345151117553None19.22Dismantling tile work in floors and roofs laid in cement mortar including stacking material to the appropriate disposal area as per direction of Engineer-in-chargeCum50.450.496.0FalseNoneNoneFalseNoneFalse4838.40
3345152117553None2.1.1Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required t complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:4:8( M7.5) Using 40 mm nominal size graded crushed coarse aggregatesCum5947.25947.27.2FalseNoneNoneFalseNoneFalse42819.840
3345153117553None9.12.2Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grou ting the joints with white cement and matching pigments etc., complete. (Size of Tile 600x600 mm) Sqm1202.251202.25101.6FalseNoneNoneFalseNoneFalse122148.60
3345154117553None1.1.1SupplyingheavygaugePVCconduitpipe.dia.mmthickconfirmingtoIS2509withsuitablesizebends,junctionboxes,adhesivepasteetc,andfixingusinginvertedwoodplugsincaseofRCCceilingandRCCwall/stonestructureorrawlplugsincaseofbrickwallsandcementplasteringthedamagedportionusingheavygauge saddles at an interval of 700mm using NF screws.Mtr69.069.020.0FalseNoneNoneFalseNoneFalse1380.00
3345155117553None1.1.1Supplying and fixing sheet Metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc 75 x 75 x 65 mmNo106.0106.02.0FalseNoneNoneFalseNoneFalse212.00
3345156117553None2.2.1Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point upto 3Mtr from tapping point to out let via switch boxNo285.0285.02.0FalseNoneNoneFalseNoneFalse570.00
3345157117553None2.2.1Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch boxNo394.0394.02.0FalseNoneNoneFalseNoneFalse788.00
3345158117553None2.2.2Long point above 6Mtr upto 10Mtr from tapping point to out let via switch boxNo555.0555.02.0FalseNoneNoneFalseNoneFalse1110.00
3345159117553None3.8Supplying 4mm thick plastic sheet with necessary nitches for fixing switches, regulators etc, and fixing on existing wooden or metal box using N.F. screwsSqm0.410.41500.0FalseNoneNoneFalseNoneFalse205.00
3345160117553None3.1.2Supplying 6A flush type socket and 6 A flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3854 6A 3/5 WayEach147.0147.05.0FalseNoneNoneFalseNoneFalse735.00
3345161117553None6.3.1Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system 48" Sweep (1200 mm) Regular modeNo1900.01900.02.0FalseNoneNoneFalseNoneFalse3800.00
3345162117553None11.13Supplying and fixing of slim patty fitting, made out of CRCA Sheet metal body with locking type holder completely wired. Excluding Ballast & Fluorescent Tube.No361.0361.02.0FalseNoneNoneFalseNoneFalse722.00
3345163117553None2.3.2Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 1.5 mmm26.026.018.0FalseNoneNoneFalseNoneFalse468.00
3345164117553None2.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 2.5 mm2m42.042.018.0FalseNoneNoneFalseNoneFalse756.00
3345165117553None2.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 4 mm2m63.063.018.0FalseNoneNoneFalseNoneFalse1134.00
17193030910000NoneNoneBuildingsConst of Room at Kanakapur Village1573039.08
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3345166117554None1.4Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work.Cum254.1254.141.513FalseNoneNoneFalseNoneFalse10548.45330
3345167117554None2.1.1Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates work as per technical specificationsCum5947.25947.212.72FalseNoneNoneFalseNoneFalse75648.3840
3345168117554None5.2Providing Coursed rubble masonry (first sort) with hard stone in foundation and plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)Cum6948.96948.911.31FalseNoneNoneFalseNoneFalse78592.0590
3345169117554None5.3Providing Coursed rubble masonry (second sort) with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sandCum6515.256515.258.11FalseNoneNoneFalseNoneFalse52838.67750
3345170117554None5.4Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)Cum6708.456708.4512.3FalseNoneNoneFalseNoneFalse82513.9350
3345171117554None1.9Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum279.3279.345.9FalseNoneNoneFalseNoneFalse12819.870
3345172117554None2.2.1Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum6601.356601.3526.33FalseNoneNoneFalseNoneFalse173813.54550
3345173117554None2.5.1Providing and removing centring shuttering propping etc and removal of form work for foundation appendix I percentage on finished rate of concrete per cumSqm330.07330.071.73FalseNoneNoneFalseNoneFalse571.02110
3345174117554None2.5.1Providing and removing centring shuttering propping etc and removal of form work for foundation appendix I percentage on finished rate of concrete per cumSqm660.14660.142.73FalseNoneNoneFalseNoneFalse1802.18220
3345175117554None2.5.1Providing and removing centring shuttering propping etc and removal of form work for foundation appendix I percentage on finished rate of concrete per cumSqm3960.813960.815.76FalseNoneNoneFalseNoneFalse22814.26560
3345176117554None2.5.1Providing and removing centring shuttering propping etc and removal of form work for foundation appendix I percentage on finished rate of concrete per cumSqm3300.683300.6813.1FalseNoneNoneFalseNoneFalse43238.9080
3345177117554None2.11Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Tonne93929.8593929.852.75FalseNoneNoneFalseNoneFalse258307.08750
3345178117554None6.7Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.Cum8621.558621.5519.64FalseNoneNoneFalseNoneFalse169327.2420
3345179117554None11.34BProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc.Sqm192.15192.15177.66FalseNoneNoneFalseNoneFalse34137.3690
3345180117554None8.6.1Providing 12 mm cement plaster with Cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerin-charge.Sqm339.15339.1584.78FalseNoneNoneFalseNoneFalse28753.1370
3345181117554None8.7Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-chargeSqm279.3279.3115.38FalseNoneNoneFalseNoneFalse32225.6340
3345182117554None8.33.1Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 L/10 m² over and including one coat of Special primer applied @ 0.75 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (The gloss should be 50% @ 60 degree angle with 10 years life)Sqm165.9165.984.78FalseNoneNoneFalseNoneFalse14065.0020
3345183117554None8.29Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 L/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm297.15297.15115.38FalseNoneNoneFalseNoneFalse34285.1670
3345184117554None9.12.2Providing and laying vitrified floor tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mmSqm1202.251202.2557.8FalseNoneNoneFalseNoneFalse69490.050
3345185117554None9.34Flooring with 25mm thick polished tandur blue stone slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab, , including cost of materials, labour, curing, polishing complete as per specificationsSqm1622.251622.2518.7FalseNoneNoneFalseNoneFalse30336.0750
3345186117554None12.12Providing Mathi/Nandi wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications. Cum130412.1130412.10.24FalseNoneNoneFalseNoneFalse31298.9040
3345187117554None12.15Providing and fixing in position fully panelled Honne wood shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. ( excluding cost of fixtures )Sqm7816.27816.28.28FalseNoneNoneFalseNoneFalse64718.1360
3345188117554None8.49Lettering with black Japan paint of approved brand and manufacture to give an even shade including preparing the surface after thoroughly cleaning the surface to remove all dirt, dust and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-chargeNo4.24.27000.0FalseNoneNoneFalseNoneFalse29400.00
3345189117554None88.84Providing Wall black in 12 mm thick with CM 1:3 and applied with primer and two coats of acyrlic emulsion black paint including finishing etc completeSqm498.75498.753.6FalseNoneNoneFalseNoneFalse1795.50
3345190117554None12.80Providing and Fixing door latch with necessary screws etc completeSqm299.25299.253.6FalseNoneNoneFalseNoneFalse1077.30
3345191117554None20.27.3Providing and Fixing bright finished brass flush bolts with necessary brass screws etc cpmpleteEach172.2172.222.0FalseNoneNoneFalseNoneFalse3788.40
3345192117554None1.1.1Electrification:Supplying heavy gauge PVC conduit pipe . dia . mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws.19/20 mm dia 2 mm thickMtr69.069.040.0FalseNoneNoneFalseNoneFalse2760.00
3345193117554None1.4.1Supplying and fixing sheet Metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc 75 x 75 x 65 mmNos106.0106.04.0FalseNoneNoneFalseNoneFalse424.00
3345194117554None2.2.1Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Short point upto 3Mtr from tapping point to out let via switch boxNos285.0285.04.0FalseNoneNoneFalseNoneFalse1140.00
3345195117554None2.2.3Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch boxNos394.0394.04.0FalseNoneNoneFalseNoneFalse1576.00
3345196117554None2.2.3Long point above 6Mtr upto 10Mtr from tapping point to out let via switch boxNos555.0555.04.0FalseNoneNoneFalseNoneFalse2220.00
3345197117554None3.8Supplying 4mm thick plastic sheet with necessary nitches for fixing switches, regulators etc, and fixing on existing wooden or metal box using N.F. screws.Sqm0.410.411500.0FalseNoneNoneFalseNoneFalse615.00
3345198117554None3.1.2Supplying 6A flush type socket and 6 A flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3854 6A 3/5 WayNos147.0147.012.0FalseNoneNoneFalseNoneFalse1764.00
3345199117554None12.60Supplying & Fixing Chemical earthling for grounding. Conduits, IC cut-outs & other equipments backfill compound which is noncorrosive, thermally conductive, potential to permissible limits, superior Fault conduction capacity, non toxic, weather resistance & capable of achieving ohmic value less than one ohm Using 4ft. Copper bonded rod with backfill compoundNos4528.04528.01.0FalseNoneNoneFalseNoneFalse4528.00
3345200117554None6.3Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing systemNos1900.01900.04.0FalseNoneNoneFalseNoneFalse7600.00
3345201117554None11.14.2Supplying and fixing of slim box fitting, made out of CRCA Sheet metal body with locking type holder completely wired. Excluding Ballast & Fluorescent Tube 1 x 4' Tube light fittingNos361.0361.02.0FalseNoneNoneFalseNoneFalse722.00
3345202117554None13.1.1Supplying and Fixing of.mm dia class A GI pipe bracket upto 2 ms long bent at suitable angle and fixing to this bracket street light fitting of all capacities to GI or GI or rail or RCC pole / wall using suitable clamps, bolts, and nuts and wiring using suitable capacity wires Using 25mm dia G.I.PipeNos978.0978.01.0FalseNoneNoneFalseNoneFalse978.00
3345203117554NoneP No 23Pre - Paid Energy Meter Single Phase, 5-30 Amps, 1.0 Accuracy Class with Key Pad Technology consumer interface unit along with pillfer proof boxNo7170.07170.01.0FalseNoneNoneFalseNoneFalse7170.00
3345204117554NoneP No 6Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 1.5 mmMtr26.026.020.0FalseNoneNoneFalseNoneFalse520.00
3345205117554NoneP No 6Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 2.5 mmMtr42.042.020.0FalseNoneNoneFalseNoneFalse840.00
3345206117554NoneP No 6Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:20104 mm2Mtr63.063.020.0FalseNoneNoneFalseNoneFalse1260.00
3345207117554None8.33.1Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Special primer applied @ 0.75 ltr /10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-chargeSqm165.9165.972.0FalseNoneNoneFalseNoneFalse11944.80
3345208117554None19.22Dismantling tile work in floors and roofs laid in cement mortar including stacking material to the appropriate disposal area as per direction of Engineer-in-chargeCum50.450.481.2FalseNoneNoneFalseNoneFalse4092.480
3345209117554None2.1.1Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required t complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:4:8( M7.5) Using 40 mm nominal size graded crushed coarse aggregatesCum5947.25947.28.12FalseNoneNoneFalseNoneFalse48291.2640
3345210117554None9.12.2Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grou ting the joints with white cement and matching pigments etc., complete. (Size of Tile 600x600 mm)Sqm1202.251202.2586.32FalseNoneNoneFalseNoneFalse103778.220
3345211117554None1.1.1SupplyingheavygaugePVCconduitpipe.dia.mmthickconfirmingtoIS2509withsuitablesizebends,junctionboxes,adhesivepasteetc,andfixingusinginvertedwoodplugsincaseofRCCceilingandRCCwall/stonestructureorrawlplugsincaseofbrickwallsandcementplasteringthedamagedportionusingheavygauge saddles at an interval of 700mm using NF screws.Mtr69.069.020.0FalseNoneNoneFalseNoneFalse1380.00
3345212117554None1.1.1Supplying and fixing sheet Metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc 75 x 75 x 65 mmNo106.0106.02.0FalseNoneNoneFalseNoneFalse212.00
3345213117554None2.2.1Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point upto 3Mtr from tapping point to out let via switch boxNo285.0285.02.0FalseNoneNoneFalseNoneFalse570.00
3345214117554None2.2.1Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch boxNo394.0394.02.0FalseNoneNoneFalseNoneFalse788.00
3345215117554None2.2.2Long point above 6Mtr upto 10Mtr from tapping point to out let via switch boxNo555.0555.02.0FalseNoneNoneFalseNoneFalse1110.00
3345216117554None1000Supplying 4mm thick plastic sheet with necessary nitches for fixing switches, regulators etc, and fixing on existing wooden or metal box using N.F. screwsSqm0.410.411000.0FalseNoneNoneFalseNoneFalse410.00
3345217117554None3.1.2Supplying 6A flush type socket and 6 A flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3854 6A 3/5 WayEach147.0147.05.0FalseNoneNoneFalseNoneFalse735.00
3345218117554None6.3.1Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system 48" Sweep (1200 mm) Regular modeNo1900.01900.02.0FalseNoneNoneFalseNoneFalse3800.00
3345219117554None11.13Supplying and fixing of slim patty fitting, made out of CRCA Sheet metal body with locking type holder completely wired. Excluding Ballast & Fluorescent Tube.No361.0361.02.0FalseNoneNoneFalseNoneFalse722.00
3345220117554None2.3.2Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 1.5 mmm26.026.022.0FalseNoneNoneFalseNoneFalse572.00
3345221117554None2.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 2.5 mm2m42.042.022.0FalseNoneNoneFalseNoneFalse924.00
3345222117554None2.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 4 mm2m63.063.022.0FalseNoneNoneFalseNoneFalse1386.00
17193030910000NoneNoneBuildingsProviding Water Supply and Repairs of Room at College at Kanakagiri1135116.3
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3345223117555NoneBasic RateRO Water Plant for Hemodialysis 500 Ltrs/Hr Capacity Specifications Plant capacity (Ltrs/Hr) 500 Plant type Microprocessor/microcontroller controlled single stage RO water system ( Feed water TDS more than 500 PPM) System type Online ,Offline Double raw water pump ( one active and the other stand by) No Raw water feed pump capacity (LPH) 1500 Micron particle filter after activated Carbon filter for removing suspended particles more than micron size 5 Distribution of RO plant water sufficient for number of dialysis machines 5-10 Material of Booster pump (offline) Stainless Steel 316No159000.0159000.01.0FalseNoneNoneFalseNoneFalse159000.00
3345224117555None1.6.1Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work.No508.2508.255.0FalseNoneNoneFalseNoneFalse27951.00
3345225117555None13.4.2Providing Submersible Pump Set of 100mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications, to work site as per necessary ammendments and instructions of engineer incharge of work. For 3 HP etc. complete. 3.00 HP - 300 LPM @ 26 m = 5 STG Outlet Dia - 2.50"Each11397.7511397.751.0FalseNoneNoneFalseNoneFalse11397.750
3345226117555None9.1.1Providing, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc. complete. NOTE: Upto 110mm dia Coil shall be used. For :HDPE PE 80 PN 6.0 HDPE Grade PE80-PN6.0, 63mm diaRmtr198.45198.4555.0FalseNoneNoneFalseNoneFalse10914.750
3345227117555None19.2.1Demolishing cement concrete manually/ by mechanical means including disposal of material to the appropriate disposal area as per direction of Engineer-in-chargeCum1746.151746.1525.0FalseNoneNoneFalseNoneFalse43653.750
3345228117555None2.2.1Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required t complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:4:8( M7.5) Using 40 mm nominal size graded crushed coarse aggregatesCum6601.356601.3532.59FalseNoneNoneFalseNoneFalse215137.99650
3345229117555None2.5.1Providing and removing centering, shuttering, strutting, propping etc.and removal of form work for Foundation, Appendix I Percentage on finished rate of Concrete Per Cum PWD SR 2023-24,P No.111, (Vol-1)Sqm3960.813960.817.59FalseNoneNoneFalseNoneFalse30062.54790
3345230117555None2.5.1Providing and removing centering, shuttering, strutting, propping etc.and removal of form work for Foundation, Appendix I Percentage on finished rate of Concrete Per Cum PWD SR 2023-24,P No.111, (Vol-1)Sqm3300.683300.6825.0FalseNoneNoneFalseNoneFalse82517.00
3345231117555None2.11.aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening,cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification a. BuildingsTonne93929.8593929.853.41FalseNoneNoneFalseNoneFalse320300.78850
3345232117555None8.6.1Providing 12 mm cement plaster with Cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm339.15339.15200.0FalseNoneNoneFalseNoneFalse67830.00
3345233117555None15.23Providing and Applying PU based Elastomeric Liquid Applied PU Waterproofing Membrane single component, cold applied, water based acrylic PU dispersion with highly elastic and UV resistant water proofing treatment to the Existing Roof surface/Chajjas/Sunken portion of WC:Bathroom applied @ 1.2 l/per m2, having tensile strength greater than 1.5N/mm2, elongation greater than 300% with solid content not less than 60% in 2 coats including surface preparation, priming the surface with water based acrylic primer @0.1 l/m2, and spreading 60 gsm geotextile between two top coats completely as per specification. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification.Sqm773.85773.85185.25FalseNoneNoneFalseNoneFalse143355.71250
3345234117555NoneI No 622Polythylene water storage tank with cover and suiatable locking arrangementLtr6.36.31000.0FalseNoneNoneFalseNoneFalse6300.00
3345235117555None13.31.3Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge Internal work - Exposed on wall 25 mm nominal dia PipesRmtr333.9333.950.0FalseNoneNoneFalseNoneFalse16695.00
17193030910000NoneNoneBuildingsConstruction of 1 Room Building at Electrification Repairs at Hulihyder Village1747481.7
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3345236117556None1.4Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work.Cum254.1254.149.613FalseNoneNoneFalseNoneFalse12606.66330
3345237117556None2.1.1Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates work as per technical specificationsCum5947.25947.215.23FalseNoneNoneFalseNoneFalse90575.8560
3345238117556None5.2Providing Coursed rubble masonry (first sort) with hard stone in foundation and plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)Cum6948.96948.99.11FalseNoneNoneFalseNoneFalse63304.4790
3345239117556None5.3Providing Coursed rubble masonry (second sort) with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sandCum6515.256515.258.54FalseNoneNoneFalseNoneFalse55640.2350
3345240117556None5.4Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)Cum6708.456708.4512.62FalseNoneNoneFalseNoneFalse84660.6390
3345241117556None1.9Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum279.3279.354.06FalseNoneNoneFalseNoneFalse15098.9580
3345242117556None2.2.1Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum6601.356601.3529.71FalseNoneNoneFalseNoneFalse196126.10850
3345243117556None2.5.1Providing and removing centring shuttering propping etc and removal of form work for foundation appendix I percentage on finished rate of concrete per cumSqm330.07330.072.3FalseNoneNoneFalseNoneFalse759.1610
3345244117556None2.5.1Providing and removing centring shuttering propping etc and removal of form work for foundation appendix I percentage on finished rate of concrete per cumSqm660.14660.143.64FalseNoneNoneFalseNoneFalse2402.90960
3345245117556None2.5.1Providing and removing centring shuttering propping etc and removal of form work for foundation appendix I percentage on finished rate of concrete per cumSqm3960.813960.817.25FalseNoneNoneFalseNoneFalse28715.87250
3345246117556None2.5.1Providing and removing centring shuttering propping etc and removal of form work for foundation appendix I percentage on finished rate of concrete per cumSqm3300.683300.6813.1FalseNoneNoneFalseNoneFalse43238.9080
3345247117556None2.11Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Tonne93929.8593929.853.14FalseNoneNoneFalseNoneFalse294939.7290
3345248117556None6.7Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.Cum8621.558621.5522.1FalseNoneNoneFalseNoneFalse190536.2550
3345249117556None11.34BProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc.Sqm192.15192.15219.24FalseNoneNoneFalseNoneFalse42126.9660
3345250117556None8.6.1Providing 12 mm cement plaster with Cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerin-charge.Sqm339.15339.1595.38FalseNoneNoneFalseNoneFalse32348.1270
3345251117556None8.7Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-chargeSqm279.3279.3129.98FalseNoneNoneFalseNoneFalse36303.4140
3345252117556None8.33.1Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 L/10 m² over and including one coat of Special primer applied @ 0.75 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (The gloss should be 50% @ 60 degree angle with 10 years life)Sqm165.9165.995.38FalseNoneNoneFalseNoneFalse15823.5420
3345253117556None8.29Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 L/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm297.15297.15129.98FalseNoneNoneFalseNoneFalse38623.5570
3345254117556None9.12.2Providing and laying vitrified floor tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mmSqm1202.251202.2574.86FalseNoneNoneFalseNoneFalse90000.4350
3345255117556None9.34Flooring with 25mm thick polished tandur blue stone slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab, , including cost of materials, labour, curing, polishing complete as per specificationsSqm1622.251622.2523.1FalseNoneNoneFalseNoneFalse37473.9750
3345256117556None12.12Providing Mathi/Nandi wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications. Cum130412.1130412.10.29FalseNoneNoneFalseNoneFalse37819.5090
3345257117556None12.15Providing and fixing in position fully panelled Honne wood shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. ( excluding cost of fixtures )Sqm7816.27816.29.72FalseNoneNoneFalseNoneFalse75973.4640
3345258117556None8.49Lettering with black Japan paint of approved brand and manufacture to give an even shade including preparing the surface after thoroughly cleaning the surface to remove all dirt, dust and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-chargeNo4.24.27000.0FalseNoneNoneFalseNoneFalse29400.00
3345259117556None88.84Providing Wall black in 12 mm thick with CM 1:3 and applied with primer and two coats of acyrlic emulsion black paint including finishing etc completeSqm498.75498.753.6FalseNoneNoneFalseNoneFalse1795.50
3345260117556None12.80Providing and Fixing door latch with necessary screws etc completeSqm299.25299.251.0FalseNoneNoneFalseNoneFalse299.250
3345261117556None20.27.3Providing and Fixing bright finished brass flush bolts with necessary brass screws etc cpmpleteEach172.2172.222.0FalseNoneNoneFalseNoneFalse3788.40
3345262117556None1.1.1Electrification:Supplying heavy gauge PVC conduit pipe . dia . mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws.19/20 mm dia 2 mm thickMtr69.069.040.0FalseNoneNoneFalseNoneFalse2760.00
3345263117556None1.4.1Supplying and fixing sheet Metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc 75 x 75 x 65 mmNos106.0106.04.0FalseNoneNoneFalseNoneFalse424.00
3345264117556None2.2.1Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Short point upto 3Mtr from tapping point to out let via switch boxNos285.0285.04.0FalseNoneNoneFalseNoneFalse1140.00
3345265117556None2.2.3Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch boxNos394.0394.04.0FalseNoneNoneFalseNoneFalse1576.00
3345266117556None2.2.3Long point above 6Mtr upto 10Mtr from tapping point to out let via switch boxNos555.0555.04.0FalseNoneNoneFalseNoneFalse2220.00
3345267117556None3.8Supplying 4mm thick plastic sheet with necessary nitches for fixing switches, regulators etc, and fixing on existing wooden or metal box using N.F. screws.Sqm0.410.411500.0FalseNoneNoneFalseNoneFalse615.00
3345268117556None3.1.2Supplying 6A flush type socket and 6 A flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3854 6A 3/5 WayNos147.0147.016.0FalseNoneNoneFalseNoneFalse2352.00
3345269117556None12.60Supplying & Fixing Chemical earthling for grounding. Conduits, IC cut-outs & other equipments backfill compound which is noncorrosive, thermally conductive, potential to permissible limits, superior Fault conduction capacity, non toxic, weather resistance & capable of achieving ohmic value less than one ohm Using 4ft. Copper bonded rod with backfill compoundNos4528.04528.01.0FalseNoneNoneFalseNoneFalse4528.00
3345270117556None6.3Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing systemNos1900.01900.06.0FalseNoneNoneFalseNoneFalse11400.00
3345271117556None11.14.2Supplying and fixing of slim box fitting, made out of CRCA Sheet metal body with locking type holder completely wired. Excluding Ballast & Fluorescent Tube 1 x 4' Tube light fittingNos361.0361.04.0FalseNoneNoneFalseNoneFalse1444.00
3345272117556None13.1.1Supplying and Fixing of.mm dia class A GI pipe bracket upto 2 ms long bent at suitable angle and fixing to this bracket street light fitting of all capacities to GI or GI or rail or RCC pole / wall using suitable clamps, bolts, and nuts and wiring using suitable capacity wires Using 25mm dia G.I.PipeNos978.0978.01.0FalseNoneNoneFalseNoneFalse978.00
3345273117556NoneP No 23Pre - Paid Energy Meter Single Phase, 5-30 Amps, 1.0 Accuracy Class with Key Pad Technology consumer interface unit along with pillfer proof boxNo7170.07170.01.0FalseNoneNoneFalseNoneFalse7170.00
3345274117556NoneP No 6Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 1.5 mmMtr26.026.040.0FalseNoneNoneFalseNoneFalse1040.00
3345275117556NoneP No 6Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 2.5 mmMtr42.042.040.0FalseNoneNoneFalseNoneFalse1680.00
3345276117556NoneP No 6Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:20104 mm2Mtr63.063.040.0FalseNoneNoneFalseNoneFalse2520.00
3345277117556None8.33.1Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Special primer applied @ 0.75 ltr /10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-chargeSqm165.9165.972.0FalseNoneNoneFalseNoneFalse11944.80
3345278117556None19.22Dismantling tile work in floors and roofs laid in cement mortar including stacking material to the appropriate disposal area as per direction of Engineer-in-chargeCum50.450.481.2FalseNoneNoneFalseNoneFalse4092.480
3345279117556None2.1.1Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required t complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:4:8( M7.5) Using 40 mm nominal size graded crushed coarse aggregatesCum5947.25947.28.12FalseNoneNoneFalseNoneFalse48291.2640
3345280117556None9.12.2Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grou ting the joints with white cement and matching pigments etc., complete. (Size of Tile 600x600 mm) Sqm1202.251202.2586.32FalseNoneNoneFalseNoneFalse103778.220
3345281117556None1.1.1SupplyingheavygaugePVCconduitpipe.dia.mmthickconfirmingtoIS2509withsuitablesizebends,junctionboxes,adhesivepasteetc,andfixingusinginvertedwoodplugsincaseofRCCceilingandRCCwall/stonestructureorrawlplugsincaseofbrickwallsandcementplasteringthedamagedportionusingheavygauge saddles at an interval of 700mm using NF screws.Mtr69.069.020.0FalseNoneNoneFalseNoneFalse1380.00
3345282117556None1.1.1Supplying and fixing sheet Metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc 75 x 75 x 65 mmNo106.0106.04.0FalseNoneNoneFalseNoneFalse424.00
3345283117556None2.2.1Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point upto 3Mtr from tapping point to out let via switch boxNo285.0285.02.0FalseNoneNoneFalseNoneFalse570.00
3345284117556None2.2.1Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch boxNo394.0394.02.0FalseNoneNoneFalseNoneFalse788.00
3345285117556None2.2.2Long point above 6Mtr upto 10Mtr from tapping point to out let via switch boxNo555.0555.02.0FalseNoneNoneFalseNoneFalse1110.00
3345286117556None3.8Supplying 4mm thick plastic sheet with necessary nitches for fixing switches, regulators etc, and fixing on existing wooden or metal box using N.F. screwsSqm0.410.411000.0FalseNoneNoneFalseNoneFalse410.00
3345287117556None3.1.2Supplying 6A flush type socket and 6 A flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3854 6A 3/5 WayEach147.0147.05.0FalseNoneNoneFalseNoneFalse735.00
3345288117556None6.3.1Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system 48" Sweep (1200 mm) Regular modeNo1900.01900.03.0FalseNoneNoneFalseNoneFalse5700.00
3345289117556None11.13Supplying and fixing of slim patty fitting, made out of CRCA Sheet metal body with locking type holder completely wired. Excluding Ballast & Fluorescent Tube.No361.0361.04.0FalseNoneNoneFalseNoneFalse1444.00
3345290117556None2.3.2Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 1.5 mmm26.026.035.0FalseNoneNoneFalseNoneFalse910.00
3345291117556None2.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 2.5 mm2m42.042.035.0FalseNoneNoneFalseNoneFalse1470.00
3345292117556None2.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 4 mm2m63.063.035.0FalseNoneNoneFalseNoneFalse2205.00
17193030920000NoneNoneBuildingsRepairs of Room at College at Kanakagiri223325.86
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3345293117557None1.4Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work.Cum254.1254.17.83FalseNoneNoneFalseNoneFalse1989.6030
3345294117557None2.1.1Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregatesCum5947.25947.22.65FalseNoneNoneFalseNoneFalse15760.080
3345295117557None5.2Providing Coursed rubble masonry (first sort) with hard stone in foundation and plinth with Cement mortar 1:6 (1 cement : 6 coarse sandCum6984.96984.91.74FalseNoneNoneFalseNoneFalse12153.7260
3345296117557None5.3Providing Coursed rubble masonry (second sort) with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)Cum6515.256515.251.39FalseNoneNoneFalseNoneFalse9056.19750
3345297117557None5.4Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)Cum6708.456708.452.09FalseNoneNoneFalseNoneFalse14020.66050
3345298117557None1.9Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum279.3279.35.04FalseNoneNoneFalseNoneFalse1407.6720
3345299117557None2.2.1Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum6601.356601.352.73FalseNoneNoneFalseNoneFalse18021.68550
3345300117557None2.5.1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesSqm3300.683300.682.33FalseNoneNoneFalseNoneFalse7690.58440
3345301117557None2.11.aSupplying, fitting and placing TMT FE 550/550D Steel Reinforcement complete as per drawing and technical specification.Building worksTonne93929.8593929.850.27FalseNoneNoneFalseNoneFalse25361.05950
3345302117557None6.7Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.Cum8621.558621.557.94FalseNoneNoneFalseNoneFalse68455.1070
3345303117557None8.6.1Providing 12 mm cement plaster with Cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerin-charge.Sqm339.15339.1579.04FalseNoneNoneFalseNoneFalse26806.4160
3345304117557None8.33.1Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 L/10 m² over and including one coat of Special primer applied @ 0.75 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (The gloss should be 50% @ 60 degree angle with 10 years life)Sqm165.9165.979.04FalseNoneNoneFalseNoneFalse13112.7360
3345305117557None9.9Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 including pointing the joints with white cement and matching pigment etc., complete.Sqm1129.81129.88.4FalseNoneNoneFalseNoneFalse9490.320
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17193030930000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17193030930000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17193030930000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17193030930000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17193030930000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneMinimum financial turnover (civil engineering construction works) not less than two times the annual payments from this contract (Rs. xxxxx Lakhs)Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNoneSatisfactoriy completed (atleast 90%) as prime contractor at-least one such similar work of value not less than Rs. xxxxxxx (80% of estimated cost of tender)Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneExecuted in any one year the following minimum quantities of work (Cement Concrete - xxxx cum, Earthwork - xxxx cum, etc) (80% of peak rate of construction)Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid Electrical License for executing building electrificatio works and should have executed similar electrical works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNonePWD Registration Certificate (Class I/II/III/IV)
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid license for executing water supply / sanitary engineering works and should have executed similar works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneOwning the following key and critical equipment for this work (xxxx, xxxx, xxxx)Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Owning the following key and critical equipment for this work
NoneNoneNoneNoneLiquid assets and /or availability of credit facilities of no less than Rs. xxxxxx Lakhs (estimated cash flow for 3 months of peak construction period)Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneLine of Credit
NoneNoneNoneNoneTotal value of civl engineering works executed and payments received in the last five years (year-wise)Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneITR Filed Copy (Mentioning PAN)
NoneNoneNoneNoneBanker Details for referenceCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Banker Details for reference
NoneNoneNoneNoneConstruction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awardedCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Others
NoneNoneNoneNoneQualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awardedCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Docuemnts
NoneNoneNoneNoneList of Financial Resources with CertificatesCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNoneReports on the financial standing of the tenderer, such as profit and loss statements and auditors reports for the last five yearsFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneITR Filed Copy (Mentioning PAN)
NoneNoneNoneNoneList of existing commitments and ongoing worksOthersList of existing commitments and ongoing works
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- List of existing commitments and ongoing works
NoneNoneNoneNoneList of works for which tenders already submittedOthersList of works for which tenders already submitted
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- List of works for which tenders already submitted
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Annual Turnover Certificate 2019-20 to 2023-24 with UDIN No CompulsoryTrueTechnical Bid
Company Registration CertificateTrueTechnical Bid
GST Certificate and Pan CardTrueTechnical Bid
Actual Post adress with Mobile NumberTrueTechnical Bid
Similar Nature of Work Done 50 PERCENTAGE OF LAST FIVE YEARSTrueTechnical Bid
Unconditonal Line of Credit 30 Percentage of APTTrueTechnical Bid
OTHER TECHNICAL DOCUMENTSTrueTechnical Bid
tenderWorkLocationList
tenderAddressNone
tenderRecallDTONone