| 1719300997000 | 0 | None | None | Buildings | Construction of Rangamandir to MLA Govt HPS School Ground in Ward No. 29 and Development of Nuli Chandayya Circle in Ward No. 22 and Construction of Welcome Board in Ward No. 17, 18 and Name board in Ward No. 16 Sindhanr Municipal Limit. | 1387837.72 | | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
|---|
| 3344232 | 117515 | None | code01 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work | Cum | 107.1 | 107.1 | 48.61 | False | None | None | False | None | False | 5206.131 | 0 | | 3344233 | 117515 | None | code02 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications - Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates | Cum | 6288.45 | 6288.45 | 6.56 | False | None | None | False | None | False | 41252.232 | 0 | | 3344234 | 117515 | None | code03 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 6708.45 | 6708.45 | 3.24 | False | None | None | False | None | False | 21735.378 | 0 | | 3344235 | 117515 | None | code04 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. | Sqm | 1292.55 | 1292.55 | 66.0 | False | None | None | False | None | False | 85308.3 | 0 | | 3344236 | 117515 | None | code05 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | Cum | 279.3 | 279.3 | 44.47 | False | None | None | False | None | False | 12420.471 | 0 | | 3344237 | 117515 | None | code06 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications - M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 9800.65 | 9800.65 | 10.29 | False | None | None | False | None | False | 100848.6885 | 0 | | 3344238 | 117515 | None | code07 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/ welding joints, tying with binding wire /soft annealed steel wire and other ancilary operations complete as per drawing and technical specification - For Buildings | Tonne | 93929.85 | 93929.85 | 0.7957 | False | None | None | False | None | False | 74739.981645 | 0 | | 3344239 | 117515 | None | code08 | Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Kgs | 142.8 | 142.8 | 250.04 | False | None | None | False | None | False | 35705.712 | 0 | | 3344240 | 117515 | None | code09 | Providing & fixing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete as per design drawings (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required as per the direction of Engineer in charge.0.63 mm thick with zinc coating not less than 275 g/ m² | Sqm | 922.95 | 922.95 | 49.0 | False | None | None | False | None | False | 45224.55 | 0 | | 3344241 | 117515 | None | code10 | Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 253.05 | 253.05 | 52.2 | False | None | None | False | None | False | 13209.21 | 0 | | 3344242 | 117515 | None | code11 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 L/10 m² over and including one coat of Special primer applied @ 0.75 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (The gloss should be 50% @ 60 degree angle with 10 years life) | Sqm | 165.9 | 165.9 | 52.2 | False | None | None | False | None | False | 8659.98 | 0 | | 3344243 | 117515 | None | code12 | Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per m2 including pointing in white cement mixed with pigment of matching shade complete. | Sqm | 1161.3 | 1161.3 | 40.5 | False | None | None | False | None | False | 47032.65 | 0 | | 3344244 | 117515 | None | code13 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications | Kgs | 593.25 | 593.25 | 510.87 | False | None | None | False | None | False | 303073.6275 | 0 | | 3344245 | 117515 | None | code14 | Supply of LED Street light luminaries with pressure die cast aluminum housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection molded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500 K, IP66 optical and electrical compartment & impact resistance of complete luminaries IK08. Power Factor 0.9 with mains, Surge Protection-Min 5KV along with Over voltage/ Overload, shortcircuit / miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver too pirate wide voltage range from 100V to 270 V 50/60 Hz application. Compliance to IS10322/ IEC60598, LM79 & LM 80 Adherence with Ro HS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with........W System Power consumption. LED Efficiency 1301m/w, nominal CRI 75. Luminaries manufacturer should havein-house facility accredited by NABL / CPRI & any Government certified agency & Design & Development facility certified by ISO9001:2008. Housing with supplier word mark /names hallbe Engraved /Embossing on the die cast housing /Body part. Warranty of 2Years against any manufacturing defect working under stand and electrical conditions as mentioned above should be given by LED manufacturer & Cree /Nichia/Lumileds/Osram make LED Source. LED Streetlight 70W | Each | 6291.6 | 6291.6 | 8.0 | False | None | None | False | None | False | 50332.8 | 0 | | 3344246 | 117515 | None | code15 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with lowconductor resistance single core in open or concealed system of wiring with specified IS-694:2010 2.5 mm2 | Mtr | 44.1 | 44.1 | 149.0 | False | None | None | False | None | False | 6570.9 | 0 | | 3344247 | 117515 | None | code16 | Supplying and Fixing of 25mm dia class A GI pipe bracket upto 1 ms long bent at suitable angle and fixing to this bracket street ligh tfitting of all capacities to GI or GIorrailor RCC pole/wall using suitable clamps, bolts, and nuts and wiring using suitable capacity wires. Using 25mm dia G.I.Pipe | Each | 500.0 | 500.0 | 8.0 | False | None | None | False | None | False | 4000.0 | 0 | | 3344248 | 117515 | None | code17 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6A One Way Switch | Each | 107.1 | 107.1 | 5.0 | False | None | None | False | None | False | 535.5 | 0 | | 3344249 | 117515 | None | code18 | Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead Cement Concrete Grade M-15 & M-20 | Cum | 979.65 | 979.65 | 1.2 | False | None | None | False | None | False | 1175.58 | 0 | | 3344250 | 117515 | None | code19 | Earth work excavation by manual means for drains,canals, waste weir draft, approach channels, key trench, foundation of Bridges and such similar works, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, excavated surface leveled and sides neatly dressed disposing off or leveling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work. In ordinary/soft rock without blasting upto 1.5 m depth | Cum | 313.95 | 313.95 | 6.0 | False | None | None | False | None | False | 1883.7 | 0 | | 3344251 | 117515 | None | code20 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates | Cum | 5947.2 | 5947.2 | 4.38 | False | None | None | False | None | False | 26048.736 | 0 | | 3344252 | 117515 | None | code21 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6639.15 | 6639.15 | 4.2 | False | None | None | False | None | False | 27884.43 | 0 | | 3344253 | 117515 | None | code22 | Form Work
As per recommendations of Technical working group, rates for formwork shall be added on percentage basis to the finished concrete item rate. For Cement Concrete Drain Walls 35% | Cum | 2323.7 | 2323.7 | 4.2 | False | None | None | False | None | False | 9759.54 | 0 | | 3344254 | 117515 | None | code23 | Distempering with dry distemper of approved brand and manufacture (two coats) of required shade on new work, over and including water thinnable priming coat to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 113.4 | 113.4 | 16.0 | False | None | None | False | None | False | 1814.4 | 0 | | 3344255 | 117515 | None | code24 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6961.5 | 6961.5 | 1.88 | False | None | None | False | None | False | 13087.62 | 0 | | 3344256 | 117515 | None | code25 | Form Work
As per recommendations of Technical working group, rates for formwork shall be added on percentage basis to the finished concrete item rate. For Cement Concrete Drain Walls 35% | Cum | 348.08 | 348.08 | 1.12 | False | None | None | False | None | False | 389.8496 | 0 | | 3344257 | 117515 | None | code26 | Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials, labour, usage
charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Kgs | 154.35 | 154.35 | 2213.0699 | False | None | None | False | None | False | 341587.339065 | 0 | | 3344258 | 117515 | None | code27 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90L/10 m² over an under coat of primer applied @ 0.80 L/10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 145.95 | 145.95 | 103.75 | False | None | None | False | None | False | 15142.3125 | 0 | | 3344259 | 117515 | None | code28 | Supply and Fixing of Radium Stickar Work | Lot | 10000.0 | 10000.0 | 2.0 | False | None | None | False | None | False | 20000.0 | 0 | | 3344260 | 117515 | None | code29 | Providing and constructing un-reinforced plain cement concrete pavement, thickness as per design, over a prepared sub base, with 43 grade cement or any other type as per Clause 1501.2.2 M20 (Grade), coarse and fine aggregates conforming to IS:383:2016, maximum size of coarse aggregate not exceeding 25 mm, mixed in a concrete mixer of not less than 0.2 cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, laying and fixing of 125 micron thick polythene film, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with shovels, rakes, compacted using needle, screed and plate vibrators and finished in continuous operation including construction joints, , primer, sealant , curing of concrete slabs for 14-days, and water finishing to lines and grade as per drawing and technical specification clause 1501 with all lead, lifts, loading & unloading charges, cost and conveyance of all materials, labour, equipments etc., complete. as per the directions of the Engineer-in-charge of the work. | Cum | 6692.7 | 6692.7 | 3.0 | False | None | None | False | None | False | 20078.1 | 0 | | 3344261 | 117515 | None | code30 | Supply and Fixing of Radium Stickerr Work | Each | 2530.0 | 2530.0 | 21.0 | False | None | None | False | None | False | 53130.0 | 0 |
|