| 1718692592000 | 0 | None | None | Other Works | CONSTRUCTION OF NEW PATTAN PANCHAYAT OFFICE PHASE-1 and LIBRARY BUILDING (PATTANA PANCHAYAT REVENUE NO-1399/1) AT BELAGALI at Narothana Phase -4 Project | 22919503.47 | | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
|---|
| 3299350 | 115006 | None | code01 | Demolishing stone rubble masonry manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material to the appropriate disposal area as per direction of Engineerin-charge .VOLUME -2 PG NO -163 IT.NO 19.9.2 cement mortar | Cum | 1328.7 | 1328.7 | 32.4 | False | None | None | False | None | False | 43049.88 | 0 | | 3299351 | 115006 | None | code02 | Dismantling dressed stone work ashlar face stone work, marble work or precast concrete work manually/ by mechanical means including stacking of serviceable and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge In cement mortar VOLUME -2 PG NO -164 IT.NO 19.10.1 | Cum | 788.98 | 788.98 | 22.4 | False | None | None | False | None | False | 17673.152 | 0 | | 3299352 | 115006 | None | code03 | 7.53 Providing & Fixing of Mineral Fibre Acoustical Suspended Ceiling System in module size of 600 x 600 x 20mm with Exposed Grid for Hospitals, Shopping malls, Commercial establishments and office complexes. The tiles should have Humidity Resistance (RH) of 99%, NRC 0.7, Light Reflectance 85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Colour White, Fire Performance UK Class 0 I Class 1 (BS 476 pt- 6 & 7)with sand texture finish andsuitable for Green Building application with Recycled content of 47%. The tile shall be laid on 24 mm wide T- section flanges colour white having rotary stitching on all T sections i.e. the Main Runner, 1200 mm & 600 mm Cross Tees with a web height of 38mm and a load carrying capacity of 15 kg/m2 &pull out strength of minimum 100 kg The T Sections should have a Galvanizing of 90 grams per m2 and need to be installed with Suspension system. SR 2021 | No | 1759.24 | 1759.24 | 34.0 | False | None | None | False | None | False | 59814.16 | 0 | | 3299353 | 115006 | None | code04 | Page 160 SR 2021 No -18.7 Design supply & installation of suspended Spider Glazing system designed to withstand the wind pressure as per IS 875 (Part-III). The Suspended System held with Spider Fittings of SS-316 Grade Steel of approved manufacturer with glass panel having 12 mm thick clear toughened glass held together with SS- 316 Grade Stainless steel Spider & bolt assembly with laminated glass fins 21 mm thick. The Glass fins and glass panel assembly shall be connected to Slab/beams by means of SS- 316 Grade stainless steel brackets & Anchor bolts and at the bottom using SS channel of 50x25x2mm using fastener & anchor bolts, non staining weather sealants of approved make, Teflon/ nylon bushes and separators to prevent bi-metallic contacts, all complete to perform as per specification and approved drawings. The complete system to be designed to accommodate thermal expansion & seismic movements etc. The joints between glass panels (6 to 8 mm) and gaps at the perimeter & in U channel of the assembly to be filled with non staining weather sealant, so as to make the entire system fully water proof & dust proof. The rate shall include all design, Engineering and shop drawing including approval from structural designer, labour, T&P, scaffolding, other incidental charges including wastage, enabling temporary services all fitting fixers nut bolts, washer, Buffer plates, fastener, anchors, SS channel laminated glass etc. all complete. For the purpose of payment, actual elevation area of Glazing including thickness of joints and the portion of Glass panel inside the SS channel shall be measured. | Sqm | 7418.06 | 7418.06 | 17.6 | False | None | None | False | None | False | 130557.856 | 0 | | 3299354 | 115006 | None | code05 | 11.2 Providing and fixing Structural Steel work riveted, bolted or weldedin built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Kg | 97.85 | 97.85 | 8000.0 | False | None | None | False | None | False | 782800.0 | 0 | | 3299355 | 115006 | None | code06 | EARTH WORK- 1.1 Earth work in surface excavation for stripping, seating of bund, Roadway, by manual means for lowering & leveling the ground for all works other than foundation & depth in all kinds of soil not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work. SR2021 | Cum | 72.1 | 72.1 | 1538.24 | False | None | None | False | None | False | 110907.104 | 0 | | 3299356 | 115006 | None | code07 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Item 2.1 Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates 2.1.2 SR 2021 | Cum | 5524.92 | 5524.92 | 184.58 | False | None | None | False | None | False | 1019789.7336 | 0 | | 3299357 | 115006 | None | code08 | 2.3 Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with superplasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technicalspecifications. (The cost of steel reinforcement & formwork to be paid separately) 2.3.2 M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Appendix I Additionalities for Formwork, Centering & Scaffolding.Foundation upto Plinth- a. Isolated- 8% | Cum | 6994.77 | 6994.77 | 120.17 | False | None | None | False | None | False | 840561.5109 | 0 | | 3299358 | 115006 | None | code09 | 2.3 Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) 2.3.2 M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates SR 2021. Appendix I Additionalities for Formwork, Centering & Scaffolding . Plinth beam of buildings- 50%. ( Revised ). | Cum | 9714.96 | 9714.96 | 23.6 | False | None | None | False | None | False | 229273.056 | 0 | | 3299359 | 115006 | None | code10 | 2.5 Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) 2.5.2 M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates SR 2021. Appendix I Additionalities for Formwork, Centering & Scaffolding . Columns - 70% - (Revised). Earth retaining strutures -10% (Revised) | Cum | 11367.49 | 11367.49 | 31.06 | False | None | None | False | None | False | 353074.2394 | 0 | | 3299360 | 115006 | None | code11 | 2.5 Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) 2.5.2 M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates SR 2021. Appendix I Additionalities for Formwork, Centering & Scaffolding . Columns - 70% - (Revised). Earth retaining strutures -10% (Revised) | Cum | 7355.44 | 7355.44 | 145.21 | False | None | None | False | None | False | 1068083.4424 | 0 | | 3299361 | 115006 | None | code12 | 2.5 Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregatesas per relevant IS Codes machine mixed with super plasticisers laid inlayers, well compacted using needle vibrators. The cost includes alllead & lifts, cost of all materials, quality confirming to the requirementsof relevant IS codes , labour, Usage charges of machinery, curing andall other appurtenances required to complete the work as per technicalspecifications. (The cost of steel reinforcement, dowel bars &formwork to be paid separately) 2.5.2 M25 Design Mix Using 20 mm nominal sizegraded crushed coarse aggregates SR 2021. Appendix I Additionalities for Formwork, Centering & Scaffolding . Architectural projection of major sections-30% | Cum | 8692.79 | 8692.79 | 5.58 | False | None | None | False | None | False | 48505.7682 | 0 | | 3299362 | 115006 | None | code13 | 5.1 Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : 5.1.1 Cement mortar 1:6 (1 cement : 6 coarse sand) SR 2021 | Cum | 4968.72 | 4968.72 | 38.57 | False | None | None | False | None | False | 191643.5304 | 0 | | 3299363 | 115006 | None | code14 | 1.9 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. SR 2021 | Cum | 210.12 | 210.12 | 974.42 | False | None | None | False | None | False | 204745.1304 | 0 | | 3299364 | 115006 | None | code15 | 6.5 Providing Brick work with common burnt clay machine moulded perforated bricks of class designation 5.0 conforming to IS: 2222 in superstructure above plinth level in cement mortar 1:6 (1 cement : 6 coarse sand) With Non modular bricks including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. SR 2021 | Cum | 9185.54 | 9185.54 | 86.94 | False | None | None | False | None | False | 798590.8476 | 0 | | 3299365 | 115006 | None | code16 | 9.31 Providing and laying heavy duty cobble stones 60mm thick interlock pavers, using cement and course sand for manufacture of blocks of approved size, shape and colour with a minimum compressive strength of 281 kg per m2 over 50mm thick sand bed ( average thickness ) and compacting with plate vibrator having 3 tons compaction force thereby forcing part of sand underneath to come up in between joints, final compaction of paver surface joints into its final level , including cost of materials, labour and Usage charges of machinery complete as per specifications. SR 2021 | Sqm | 1119.61 | 1119.61 | 172.92 | False | None | None | False | None | False | 193602.9612 | 0 | | 3299366 | 115006 | None | code17 | 2.5 Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) 2.5.2 M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates SR 2021. Appendix I Additionalities for Formwork, Centering & Scaffolding Chejjas, Canopy & Other Architectural projections of minor sections- 45% | Cum | 9695.8 | 9695.8 | 0.81 | False | None | None | False | None | False | 7853.598 | 0 | | 3299367 | 115006 | None | code18 | 2.5 Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) 2.5.2 M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates SR 2021. Appendix I Additionalities for Formwork, Centering & Scaffolding Beams & Lintels of Building- 60% (Revised) | Cum | 10698.82 | 10698.82 | 44.43 | False | None | None | False | None | False | 475348.5726 | 0 | | 3299368 | 115006 | None | code19 | 2.5 Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) 2.5.2 M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates SR 2021. Appendix I Additionalities for Formwork, Centering & Scaffolding. Slabs- 50% (revised) Chejjas, Canopy & Other | Cum | 10030.14 | 10030.14 | 53.8 | False | None | None | False | None | False | 539621.532 | 0 | | 3299369 | 115006 | None | code20 | 2.5 Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) 2.5.2 M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates SR 2021. Appendix I Additionalities for Formwork, Centering & Scaffolding. Architectural projections of minor sections- 45% | Cum | 9695.8 | 9695.8 | 6.96 | False | None | None | False | None | False | 67482.768 | 0 | | 3299370 | 115006 | None | code21 | 11.32 Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) SR 2021 | Kg | 90.64 | 90.64 | 46493.85 | False | None | None | False | None | False | 4214202.564 | 0 | | 3299371 | 115006 | None | code22 | 12.11 Providing Honne wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. SR 2021 | Cum | 93104.79 | 93104.79 | 0.35 | False | None | None | False | None | False | 32586.6765 | 0 | | 3299372 | 115006 | None | code23 | 12.15 Providing and fixing in position fully panelled Honne wood shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. ( excluding cost of fixtures ) SR 2021 | Sqm | 2136.22 | 2136.22 | 6.64 | False | None | None | False | None | False | 14184.5008 | 0 | | 3299373 | 115006 | None | code24 | 11.3 Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer including cost of materials ,labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. SR 2021 | Sqm | 6759.89 | 6759.89 | 3.15 | False | None | None | False | None | False | 21293.6535 | 0 | | 3299374 | 115006 | None | code25 | 11.35.2.2 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Powder coated aluminium (minimum thickness of powder coating 50 micron) including cost of materials, labour, usage charges of machinery complete as per specifications. SR 2021 | Kg | 468.65 | 468.65 | 168.08 | False | None | None | False | None | False | 78770.692 | 0 | | 3299375 | 115006 | None | code26 | 11.37.1 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness (weight not less than 10kg/ m) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. SR 2021 | Sqm | 821.94 | 821.94 | 14.32 | False | None | None | False | None | False | 11770.1808 | 0 | | 3299376 | 115006 | None | code27 | 8.3.1 Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. SR 2021 | Sqm | 316.21 | 316.21 | 765.21 | False | None | None | False | None | False | 241967.0541 | 0 | | 3299377 | 115006 | None | code28 | 8.7 Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. SR 2021 | Sqm | 330.63 | 330.63 | 506.84 | False | None | None | False | None | False | 167576.5092 | 0 | | 3299378 | 115006 | None | code29 | 8.1.1 Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. SR 2021 | Sqm | 224.54 | 224.54 | 385.8 | False | None | None | False | None | False | 86627.532 | 0 | | 3299379 | 115006 | None | code30 | 8.51 Providing and applying white cement based putty of averagethickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. | Sqm | 85.49 | 85.49 | 775.77 | False | None | None | False | None | False | 66320.5773 | 0 | | 3299380 | 115006 | None | code31 | 9.17 Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete. 9.17.2 Size of Tile 600x600 mm . SR 2021 | Sqm | 1144.33 | 1144.33 | 72.95 | False | None | None | False | None | False | 83478.8735 | 0 | | 3299381 | 115006 | None | code32 | 9.24 Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent. SR 2021 | Sqm | 2967.43 | 2967.43 | 101.9 | False | None | None | False | None | False | 302381.117 | 0 | | 3299382 | 115006 | None | code33 | 8.29 Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m) over and including priming coat of exterior primer applied @ 2.20kg/10 m to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops.and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge | Sqm | 214.24 | 214.24 | 765.21 | False | None | None | False | None | False | 163938.5904 | 0 | | 3299383 | 115006 | None | code34 | 8.35.2 Painting with silicon & acrylic emulsion based water thinnable sealer of approved brand and manufacture on wet or patchy portion of plastered surfaces :Two coats with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.8.35.2 Painting with silicon & acrylic emulsion based water thinnable sealer of approved brand and manufacture on wet or patchy portion of plastered surfaces :Two coats with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. SR 2021 | Sqm | 98.88 | 98.88 | 752.76 | False | None | None | False | None | False | 74432.9088 | 0 | | 3299384 | 115006 | None | code35 | 8.40 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. SR 2021 | Sqm | 92.7 | 92.7 | 9.45 | False | None | None | False | None | False | 876.015 | 0 | | 3299385 | 115006 | None | code36 | 12.54 Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge. SR 2021 | Sqm | 489.25 | 489.25 | 12.39 | False | None | None | False | None | False | 6061.8075 | 0 | | 3299386 | 115006 | None | code37 | 12.55 Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges. 12.55.2 -do- with one side prelam . SR 2021 | Sqm | 2941.68 | 2941.68 | 6.93 | False | None | None | False | None | False | 20385.8424 | 0 | | 3299387 | 115006 | None | code38 | 11.34A Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding.SR 2021 | Kg | 134.93 | 134.93 | 43.2 | False | None | None | False | None | False | 5828.976 | 0 | | 3299388 | 115006 | None | code39 | Providing & fixing M.S. Gate as per chief Architect Drawing, using 50mmX 50mm 14 guage M.S. Hollow pipe frame work bent to ornamental shape as shown in the drawing and 35mmx6mm and 16x16mm square rods for verticals alternatively spaced at 4cms c/c in two halves and 40mmx6mm M.S. flats for horizontal member and at the top cast iron spikes are provided at alternatve vertical members as shown in the drawing etc., complete. All the steel surface should be thouroughly cleaned free of rust and painted with anti-corrosive paint(shop paint) etc., complete. The work includes cost of all materials , labour charges for all item of work, the hire charges for welding, cutting and grinding equipment, and electricity charges, with lead & lift, loading & unloading charges, etc., complete as per specification. Sl. No. 7.37, Page No. 45, PWD, Belagavi SR 2018-19 | Sqm | 3192.72 | 3192.72 | 18.26 | False | None | None | False | None | False | 58299.0672 | 0 | | 3299389 | 115006 | None | code40 | 8.40 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 92.7 | 92.7 | 20.78 | False | None | None | False | None | False | 1926.306 | 0 | | 3299390 | 115006 | None | code41 | 11.28 Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts,bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of he Engineer-in-Charge. | Kg | 515.0 | 515.0 | 202.0 | False | None | None | False | None | False | 104030.0 | 0 | | 3299391 | 115006 | None | code42 | 14.2 Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required :14.2.2 W.C. pan with ISI marked black solid plastic seat and lid . SR 2021 | No | 4039.66 | 4039.66 | 4.0 | False | None | None | False | None | False | 16158.64 | 0 | | 3299392 | 115006 | None | code43 | 10.14 Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of Many size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per m2, including pointing in white cement mixed with pigment of matching shade complete. SR 2021 (300 X 450 mm) | Sqm | 1003.22 | 1003.22 | 49.0 | False | None | None | False | None | False | 49157.78 | 0 | | 3299393 | 115006 | None | code44 | 14.7 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: 14.7.1 White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps . SR 2021 | No | 2604.87 | 2604.87 | 4.0 | False | None | None | False | None | False | 10419.48 | 0 | | 3299394 | 115006 | None | code45 | first floor 2.5 Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) 2.5.2 M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates SR 2021. Appendix I Additionalities for Formwork, Centering & Scaffolding . Columns - 70% - (Revised). | Cum | 11481.17 | 11481.17 | 8.64 | False | None | None | False | None | False | 99197.3088 | 0 | | 3299395 | 115006 | None | code46 | 6.5 Providing Brick work with common burnt clay machine moulded perforated bricks of class designation 5.0 conforming to IS: 2222 in superstructure above plinth level in cement mortar 1:6 (1 cement : 6 coarse sand) With Non modular bricks including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. SR 2021 | Cum | 9277.4 | 9277.4 | 19.54 | False | None | None | False | None | False | 181280.396 | 0 | | 3299396 | 115006 | None | code47 | 2.5 Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) 2.5.2 M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates SR 2021. Appendix I Additionalities for Formwork, Centering & Scaffolding Chejjas, Canopy & Other Architectural projections of minor sections- 45% | Cum | 9792.76 | 9792.76 | 0.34 | False | None | None | False | None | False | 3329.5384 | 0 | | 3299397 | 115006 | None | code48 | 2.5 Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) 2.5.2 M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates SR 2021. Appendix I Additionalities for Formwork, Centering & Scaffolding Beams & Lintels of Building- 60% (Revised) | Cum | 10805.8 | 10805.8 | 0.76 | False | None | None | False | None | False | 8212.408 | 0 | | 3299398 | 115006 | None | code49 | 2.5 Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) 2.5.2 M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates SR 2021. Appendix I Additionalities for Formwork, Centering & Scaffolding Beams & Lintels of Building- 60% (Revised) | Cum | 10805.8 | 10805.8 | 4.59 | False | None | None | False | None | False | 49598.622 | 0 | | 3299399 | 115006 | None | code50 | 2.5 Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) 2.5.2 M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates SR 2021. Appendix I Additionalities for Formwork, Centering & Scaffolding. Slabs- 50% | Cum | 10130.44 | 10130.44 | 4.5 | False | None | None | False | None | False | 45586.98 | 0 | | 3299400 | 115006 | None | code51 | 2.5 Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) 2.5.2 M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates SR 2021. Appendix I Additionalities for Formwork, Centering & Scaffolding. Chejjas, Canopy & Other Architectural projections of minor sections- 45% | Cum | 9792.76 | 9792.76 | 0.6 | False | None | None | False | None | False | 5875.656 | 0 | | 3299401 | 115006 | None | code52 | 11.32 Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) SR 2021 | Kg | 91.55 | 91.55 | 4996.38 | False | None | None | False | None | False | 457418.589 | 0 | | 3299402 | 115006 | None | code53 | 12.11 Providing Honne wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. SR 2021 | Cum | 94035.84 | 94035.84 | 0.16 | False | None | None | False | None | False | 15045.7344 | 0 | | 3299403 | 115006 | None | code54 | 12.15 Providing and fixing in position fully panelled Honne wood shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. ( excluding cost of fixtures ) SR 2021 | Sqm | 2157.58 | 2157.58 | 3.32 | False | None | None | False | None | False | 7163.1656 | 0 | | 3299404 | 115006 | None | code55 | 11.3 Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer including cost of materials ,labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. SR 2021 | Sqm | 6827.49 | 6827.49 | 3.6 | False | None | None | False | None | False | 24578.964 | 0 | | 3299405 | 115006 | None | code56 | 11.35.2.2 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Powder coated aluminium (minimum thickness of powder coating 50 micron) including cost of materials, labour, usage charges of machinery complete as per specifications. SR 2021 | Kg | 473.34 | 473.34 | 74.92 | False | None | None | False | None | False | 35462.6328 | 0 | | 3299406 | 115006 | None | code57 | 11.37.1 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness (weight not less than 10kg/ m) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. SR 2021 | Sqm | 830.16 | 830.16 | 5.0 | False | None | None | False | None | False | 4150.8 | 0 | | 3299407 | 115006 | None | code58 | 8.4.25 Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. SR 2021 | Sqm | 319.37 | 319.37 | 86.12 | False | None | None | False | None | False | 27504.1444 | 0 | | 3299408 | 115006 | None | code59 | 8.7 Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. SR 2021 | Sqm | 333.94 | 333.94 | 145.13 | False | None | None | False | None | False | 48464.7122 | 0 | | 3299409 | 115006 | None | code60 | 8.1.1 Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. SR 2021 | Sqm | 226.79 | 226.79 | 34.0 | False | None | None | False | None | False | 7710.86 | 0 | | 3299410 | 115006 | None | code61 | 8.51 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. | Sqm | 86.34 | 86.34 | 137.95 | False | None | None | False | None | False | 11910.603 | 0 | | 3299411 | 115006 | None | code62 | 9.24 Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent. SR 2021. ( @ 66%, 20mm grey granite 20%, 20mm thick black granite 14%) with nosing | Sqm | 2997.1 | 2997.1 | 30.0 | False | None | None | False | None | False | 89913.0 | 0 | | 3299412 | 115006 | None | code63 | 8.29 Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m) over and including priming coat of exterior primer applied @ 2.20kg/10 m to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops.and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge | Sqm | 216.38 | 216.38 | 86.12 | False | None | None | False | None | False | 18634.6456 | 0 | | 3299413 | 115006 | None | code64 | 8.35.2 Painting with silicon & acrylic emulsion based water thinnable sealer of approved brand and manufacture on wet or patchy portion of plastered surfaces :Two coats with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.8.35.2 Painting with silicon & acrylic emulsion based water thinnable sealer of approved brand and manufacture on wet or patchy portion of plastered surfaces :Two coats with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. SR 2021 | Sqm | 99.87 | 99.87 | 171.95 | False | None | None | False | None | False | 17172.6465 | 0 | | 3299414 | 115006 | None | code65 | 8.40 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. SR 2021 | Sqm | 93.63 | 93.63 | 5.04 | False | None | None | False | None | False | 471.8952 | 0 | | 3299415 | 115006 | None | code66 | 12.54 Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge. SR 2021 | Sqm | 494.14 | 494.14 | 0.99 | False | None | None | False | None | False | 489.1986 | 0 | | 3299416 | 115006 | None | code67 | 12.55 Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges. 12.55.2 -do- with one side prelam . SR 2021 | Sqm | 2971.1 | 2971.1 | 3.78 | False | None | None | False | None | False | 11230.758 | 0 | | 3299417 | 115006 | None | code68 | 11.34A Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding.SR 2021 | Kg | 136.28 | 136.28 | 43.2 | False | None | None | False | None | False | 5887.296 | 0 | | 3299418 | 115006 | None | code69 | 8.40 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 93.63 | 93.63 | 2.52 | False | None | None | False | None | False | 235.9476 | 0 | | 3299419 | 115006 | None | code70 | 11.28 Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts,bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Kg | 520.15 | 520.15 | 66.0 | False | None | None | False | None | False | 34329.9 | 0 | | 3299420 | 115006 | None | code71 | 14.2 Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required :14.2.2 W.C. pan with ISI marked black solid plastic seat and lid . SR 2021 | Nos | 4080.06 | 4080.06 | 2.0 | False | None | None | False | None | False | 8160.12 | 0 | | 3299421 | 115006 | None | code72 | 10.14 Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per m2, including pointing in white cement mixed with pigment of matching shade complete. SR 2021 (300 X 450 mm) | Sqm | 1013.25 | 1013.25 | 22.05 | False | None | None | False | None | False | 22342.1625 | 0 | | 3299422 | 115006 | None | code73 | 14.7 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: 14.7.1 White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps . SR 2021 | No | 2630.92 | 2630.92 | 2.0 | False | None | None | False | None | False | 5261.84 | 0 | | 3299423 | 115006 | None | code74 | 7.53 Providing & Fixing of Mineral Fibre Acoustical Suspended Ceiling System in module size of 600 x 600 x 20mm with Exposed Grid for Hospitals, Shopping malls, Commercial establishments and office complexes. The tiles should have Humidity Resistance (RH) of 99%, NRC 0.7, Light Reflectance 85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Colour White, Fire Performance UK Class 0 I Class 1 (BS 476 pt- 6 & 7)with sand texture finish andsuitable for Green Building application with Recycled content of 47%. The tile shall be laid on 24 mm wide T- section flanges colour white having rotary stitching on all T sections i.e. the Main Runner, 1200 mm & 600 mm Cross Tees with a web height of 38mm and a load carrying capacity of 15 kg/m2 &pull out strength of minimum 100 kg The T Sections should have a Galvanizing of 90 grams per m2 and need to be installed with Suspension system. SR 2021 | No | 1776.83 | 1776.83 | 34.0 | False | None | None | False | None | False | 60412.22 | 0 | | 3299424 | 115006 | None | code75 | Page 160 SR 2021 No -18.7 Design supply & installation of suspended Spider Glazing system designed to withstand the wind pressure as per IS 875 (Part-III). The Suspended System held with Spider Fittings of SS-316 Grade Steel of approved manufacturer with glass panel having 12 mm thick clear toughened glass held together with SS- 316 Grade Stainless steel Spider & bolt assembly with laminated glass fins 21 mm thick. The Glass fins and glass panel assembly shall be connected to Slab/beams by means of SS- 316 Grade stainless steel brackets & Anchor bolts and at the bottom using SS channel of 50x25x2mm using fastener & anchor bolts, non staining weather sealants of approved make, Teflon/ nylon bushes and separators to prevent bi-metallic contacts, all complete to perform as per specification and approved drawings. The complete system to be designed to accommodate thermal expansion & seismic movements etc. The joints between glass panels (6 to 8 mm) and gaps at the perimeter & in U channel of the assembly to be filled with non staining weather sealant, so as to make the entire system fully water proof & dust proof. The rate shall include all design, Engineering and shop drawing including approval from structural designer, labour, T&P, scaffolding, other incidental charges including wastage, enabling temporary services all fitting fixers nut bolts, washer, Buffer plates, fastener, anchors, SS channel laminated glass etc. all complete. For the purpose of payment, actual elevation area of Glazing including thickness of joints and the portion of Glass panel inside the SS channel shall be measured. | Sqm | 7492.24 | 7492.24 | 17.6 | False | None | None | False | None | False | 131863.424 | 0 | | 3299425 | 115006 | None | code76 | 11.2 Providing and fixing Structural Steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Kg | 97.85 | 97.85 | 8000.0 | False | None | None | False | None | False | 782800.0 | 0 | | 3299426 | 115006 | None | code77 | 15.1 Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge. | Sqm | 775.02 | 775.02 | 30.0 | False | None | None | False | None | False | 23250.6 | 0 | | 3299427 | 115006 | None | code78 | B ) GROUND FLOOR ESTIMATION 2.5 Providing and laying in position Reinforced cement concrete for allSuper structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregatesas per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) 2.5.2 M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates SR 2021. Appendix I Additionalities for Formwork, Centering & Scaffolding . Columns - 70% - (Revised). | Cum | 11367.49 | 11367.49 | 15.52 | False | None | None | False | None | False | 176423.4448 | 0 | | 3299428 | 115006 | None | code79 | 2.5 Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) 2.5.2 M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates SR 2021. Appendix I Additionalities for Formwork, Centering & Scaffolding . Architectural projection of major sections-30% | Cum | 8692.79 | 8692.79 | 3.39 | False | None | None | False | None | False | 29468.5581 | 0 | | 3299429 | 115006 | None | code80 | 6.5 Providing Brick work with common burnt clay machine moulded perforated bricks of class designation 5.0 conforming to IS: 2222 in superstructure above plinth level in cement mortar 1:6 (1 cement : 6 coarse sand) With Non modular bricks including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. SR 2021 | Cum | 9185.54 | 9185.54 | 117.01 | False | None | None | False | None | False | 1074800.0354 | 0 | | 3299430 | 115006 | None | code81 | 2.5 Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) 2.5.2 M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates SR 2021. Appendix I Additionalities for Formwork, Centering & Scaffolding Chejjas, Canopy & Other Architectural projections of minor sections- 45% | Cum | 9695.8 | 9695.8 | 1.44 | False | None | None | False | None | False | 13961.952 | 0 | | 3299431 | 115006 | None | code82 | 2.5 Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) 2.5.2 M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates SR 2021. Appendix I Additionalities for Formwork, Centering & Scaffolding Beams & Lintels of Building- 60% (Revised) | Cum | 10698.82 | 10698.82 | 6.76 | False | None | None | False | None | False | 72324.0232 | 0 | | 3299432 | 115006 | None | code83 | 2.5 Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) 2.5.2 M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates SR 2021. Appendix I Additionalities for Formwork, Centering & Scaffolding Beams & Lintels of Building- 60% (Revised) | Cum | 10698.82 | 10698.82 | 29.25 | False | None | None | False | None | False | 312940.485 | 0 | | 3299433 | 115006 | None | code84 | 2.5 Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) 2.5.2 M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates SR 2021. Appendix I Additionalities for Formwork, Centering & Scaffolding Beams & Lintels of Building- 50% (Revised) | Cum | 10030.14 | 10030.14 | 41.08 | False | None | None | False | None | False | 412038.1512 | 0 | | 3299434 | 115006 | None | code85 | 2.5 Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) 2.5.2 M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates SR 2021. Appendix I Additionalities for Formwork, Centering & Scaffolding Beams & Lintels of Building- 45% (Revised) | Cum | 9695.8 | 9695.8 | 6.7 | False | None | None | False | None | False | 64961.86 | 0 | | 3299435 | 115006 | None | code86 | 11.32 Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) SR 2021 | Kg | 90.64 | 90.64 | 11499.28 | False | None | None | False | None | False | 1042294.7392 | 0 | | 3299436 | 115006 | None | code87 | 12.15 Providing and fixing in position fully panelled Honne wood shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. ( excluding cost of fixtures ) SR 2021 | Sqm | 2136.22 | 2136.22 | 28.13 | False | None | None | False | None | False | 60091.8686 | 0 | | 3299437 | 115006 | None | code88 | 12.11 Providing Honne wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. SR 2021 | Cum | 93104.79 | 93104.79 | 1.1 | False | None | None | False | None | False | 102415.269 | 0 | | 3299438 | 115006 | None | code89 | 11.3 Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer including cost of materials ,labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. SR 2021 | Sqm | 6759.89 | 6759.89 | 7.32 | False | None | None | False | None | False | 49482.3948 | 0 | | 3299439 | 115006 | None | code90 | 11.35.2.2 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Powder coated aluminium (minimum thickness of powder coating 50 micron) including cost of materials, labour, usage charges of machinery complete as per specifications. SR 2021 | Kg | 468.65 | 468.65 | 275.18 | False | None | None | False | None | False | 128963.107 | 0 | | 3299440 | 115006 | None | code91 | 8.3.1 Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. SR 2021 | Sqm | 316.21 | 316.21 | 602.11 | False | None | None | False | None | False | 190393.2031 | 0 | | 3299441 | 115006 | None | code92 | 8.7 Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. SR 2021 | Sqm | 330.63 | 330.63 | 1047.26 | False | None | None | False | None | False | 346255.5738 | 0 | | 3299442 | 115006 | None | code93 | 8.1.1 Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. SR 2021 | Sqm | 224.54 | 224.54 | 321.94 | False | None | None | False | None | False | 72288.4076 | 0 | | 3299443 | 115006 | None | code94 | 8.51 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. | Sqm | 85.49 | 85.49 | 1308.16 | False | None | None | False | None | False | 111834.5984 | 0 | | 3299444 | 115006 | None | code95 | 9.17 Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete. 9.17.2 Size of Tile 600x600 mm . SR 2021 | Sqm | 1144.33 | 1144.33 | 203.14 | False | None | None | False | None | False | 232459.1962 | 0 | | 3299445 | 115006 | None | code96 | 9.17 Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete. 9.17.2 Size of Tile 600x600 mm . SR 2021 | Sqm | 1144.33 | 1144.33 | 76.98 | False | None | None | False | None | False | 88090.5234 | 0 | | 3299446 | 115006 | None | code97 | 9.24 Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement :4coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent. SR 2021. ( @ 66%, 20mm grey granite 20%, 20mm thick black granite 14%) with nosing | Sqm | 2967.43 | 2967.43 | 19.88 | False | None | None | False | None | False | 58992.5084 | 0 | | 3299447 | 115006 | None | code98 | 8.29 Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m) over and including priming coat of exterior primer applied @ 2.20kg/10 m to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops.and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 214.24 | 214.24 | 602.11 | False | None | None | False | None | False | 128996.0464 | 0 | | 3299448 | 115006 | None | code99 | 8.35.2 Painting with silicon & acrylic emulsion based water thinnable sealer of approved brand and manufacture on wet or patchy portion of plasteredsurfaces :Two coats with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.8.35.2 Painting with silicon & acrylic emulsion based water thinnable sealer of approved brand and manufacture on wet or patchy portion of plastered surfaces :Two coats with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. SR 2021 | Sqm | 98.88 | 98.88 | 1047.26 | False | None | None | False | None | False | 103553.0688 | 0 | | 3299449 | 115006 | None | code100 | 8.35.2 Painting with silicon & acrylic emulsion based water thinnable sealer of approved brand and manufacture on wet or patchy portion of plastered surfaces :Two coats with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.8.35.2 Painting with silicon & acrylic emulsion based water thinnable sealer of approved brand and manufacture on wet or patchy portion of plastered surfaces :Two coats with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. SR 2021 | Sqm | 98.88 | 98.88 | 321.94 | False | None | None | False | None | False | 31833.4272 | 0 | | 3299450 | 115006 | None | code101 | 12.54 Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge. SR 2021 | Sqm | 489.25 | 489.25 | 45.6 | False | None | None | False | None | False | 22309.8 | 0 | | 3299451 | 115006 | None | code102 | 12.55 Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges. 12.55.2 -do- with one side prelam . SR 2021 | Sqm | 2941.68 | 2941.68 | 12.6 | False | None | None | False | None | False | 37065.168 | 0 | | 3299452 | 115006 | None | code103 | 8.40 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. SR 2021 | Sqm | 92.7 | 92.7 | 24.33 | False | None | None | False | None | False | 2255.391 | 0 | | 3299453 | 115006 | None | code104 | 11.28 Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts,bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Kg | 515.0 | 515.0 | 115.2 | False | None | None | False | None | False | 59328.0 | 0 | | 3299454 | 115006 | None | code105 | 14.2 Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required :14.2.2 W.C. pan with ISI marked black solid plastic seat and lid . SR 2021 | Nos | 4039.66 | 4039.66 | 8.0 | False | None | None | False | None | False | 32317.28 | 0 | | 3299455 | 115006 | None | code106 | 10.14 Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green,black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per m2, including pointing in white cement mixed with pigment of matching shade complete. SR 2021 (300 X 450 mm) | Sqm | 1003.22 | 1003.22 | 141.53 | False | None | None | False | None | False | 141985.7266 | 0 | | 3299456 | 115006 | None | code107 | 14.7A Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required: using White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer. SR 2021 | Nos | 3706.97 | 3706.97 | 4.0 | False | None | None | False | None | False | 14827.88 | 0 | | 3299457 | 115006 | None | code108 | 14.7 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: 14.7.1 White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps . SR 2021 | Nos | 2604.87 | 2604.87 | 3.0 | False | None | None | False | None | False | 7814.61 | 0 | | 3299458 | 115006 | None | code109 | 14.46 Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water (250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-charge. SR 2021 | Nos | 6247.98 | 6247.98 | 6.0 | False | None | None | False | None | False | 37487.88 | 0 | | 3299459 | 115006 | None | code110 | 14.31 Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. SR 2021 | Nos | 1000.13 | 1000.13 | 3.0 | False | None | None | False | None | False | 3000.39 | 0 | | 3299460 | 115006 | None | code111 | 14.32 Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :14.32.2 Rectangular shape 453x357 mm. SR 2021 | Nos | 895.07 | 895.07 | 2.0 | False | None | None | False | None | False | 1790.14 | 0 | | 3299461 | 115006 | None | code112 | 10.20 Providing and fixing of clay tiles for cladding tiles of size 230x75x10mm thick on 12mm thick cement mortar 1:3 (1 cement : 3 coarse sand) & jointed with Adhesive/cement slurry over rough plaster surface excluding cost of rough plastered surface and the surface is painted with red apex paint and black apex paint into the groves. The work includes cost of all materials, labour charges for all items of work, usage charges for equipment, etc., complete as per specification. SR 2021 | Sqm | 1909.62 | 1909.62 | 39.86 | False | None | None | False | None | False | 76117.4532 | 0 | | 3299462 | 115006 | None | code113 | 7.53 Providing & Fixing of Mineral Fibre Acoustical Suspended Ceiling System in module size of 600 x 600 x 20mm with Exposed Grid for Hospitals, Shopping malls, Commercial establishments and office complexes. The tiles should have Humidity Resistance (RH) of 99%, NRC 0.7, Light Reflectance 85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Colour White, Fire Performance UK Class 0 I Class 1 (BS 476 pt- 6 & 7)with sand texture finish andsuitable for Green Building application with Recycled content of 47%. The tile shall be laid on 24 mm wide T- section flanges colour white having rotary stitching on all T sections i.e. the Main Runner, 1200 mm & 600 mm Cross Tees with a web height of 38mm and a load carrying capacity of 15 kg/m2 &pull out strength of minimum 100 kg The T Sections should have a Galvanizing of 90 grams per m2 and need to be installed with Suspension system. SR 2021 | Sqm | 1759.24 | 1759.24 | 20.64 | False | None | None | False | None | False | 36310.7136 | 0 | | 3299463 | 115006 | None | code114 | 11.35.2.2 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Powder coated aluminium (minimum thickness of powder coating 50 micron) including cost of materials, labour, usage charges of machinery complete as per specifications. SR 2021 | Kg | 473.34 | 473.34 | 285.3 | False | None | None | False | None | False | 135043.902 | 0 | | 3299464 | 115006 | None | code115 | 11.37.1 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness (weight not less than 10kg/ m) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. SR 2021 | Sqm | 821.94 | 821.94 | 28.53 | False | None | None | False | None | False | 23449.9482 | 0 | | 3299465 | 115006 | None | code116 | Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge Si no.15.1 of Pg no.133 of PWD SR-2021-22, VOLUME2. | Sqm | 775.02 | 775.02 | 328.64 | False | None | None | False | None | False | 254702.5728 | 0 | | 3299466 | 115006 | None | code117 | Supplying and wiring adopting loop system in the existing PVC conduit/ pipe using copper PVC insulated multistrand 2 x 1.5 sq.mm wire without switch on the existing the matel box the other end of the wires shall be terminated with sufficient loose length in a PVC round block , complete point wiring using class A Materials for each outlet Short point upto 3 mts from tapping point to out let via switch | Point | 251.0 | 251.0 | 49.0 | False | None | None | False | None | False | 12299.0 | 0 | | 3299467 | 115006 | None | code118 | Supplying and wiring adopting loop system in the existing PVC conduit/ pipe using copper PVC insulated multistrand 2 x 1.5 sq.mm wire without switch on the existing the matel box the other end of the wires shall be terminated with sufficient loose length in a PVC round block , completeMedium point above 3 mts upto 6mts from tapping point to outlet via switch | Point | 361.0 | 361.0 | 105.0 | False | None | None | False | None | False | 37905.0 | 0 | | 3299468 | 115006 | None | code119 | Supplying and wiring adopting loop system in the existing PVC conduit/ pipe using copper PVC insulated multistrand 2 x 1.5 sq.mm wire without switch on the existing the matel box the other end of the wires shall be terminated with sufficient loose length in a PVC round block , completeLong point above 6 mts upto 10 mts from tapping point to outlet via switch | Point | 542.0 | 542.0 | 45.0 | False | None | None | False | None | False | 24390.0 | 0 | | 3299469 | 115006 | None | code120 | Supplying and wiring adopting loop system in the existing PVC conduit/ pipe using copper PVC insulated multistrand 2 x 1.5 sq.mm wire without switch on the existing the matel box the other end of the wires shall be terminated with sufficient loose length in a PVC round block , completeTwo outlet in a row above 3mts upto 6 mts from tapping point to outlet via switches | Point | 750.0 | 750.0 | 3.0 | False | None | None | False | None | False | 2250.0 | 0 | | 3299470 | 115006 | None | code121 | Supplying and flush mounting powder coated/Galavanized metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall1 - 3 way | Each | 123.0 | 123.0 | 100.0 | False | None | None | False | None | False | 12300.0 | 0 | | 3299471 | 115006 | None | code122 | Supplying and flush mounting powder coated/Galavanized metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall4 - 5 Way | Each | 138.0 | 138.0 | 35.0 | False | None | None | False | None | False | 4830.0 | 0 | | 3299472 | 115006 | None | code123 | Supplying and flush mounting powder coated/Galavanized metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall6 Way | Each | 212.0 | 212.0 | 35.0 | False | None | None | False | None | False | 7420.0 | 0 | | 3299473 | 115006 | None | code124 | Supplying and flush mounting powder coated/Galavanized metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall8 Way | Each | 250.0 | 250.0 | 40.0 | False | None | None | False | None | False | 10000.0 | 0 | | 3299474 | 115006 | None | code125 | Supplying and flush mounting powder coated/Galavanized metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall10-12Way | Each | 325.0 | 325.0 | 40.0 | False | None | None | False | None | False | 13000.0 | 0 | | 3299475 | 115006 | None | code126 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box1 to 3 module | Each | 152.0 | 152.0 | 95.0 | False | None | None | False | None | False | 14440.0 | 0 | | 3299476 | 115006 | None | code127 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box4 module | Each | 175.0 | 175.0 | 35.0 | False | None | None | False | None | False | 6125.0 | 0 | | 3299477 | 115006 | None | code128 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box6 module | Each | 244.0 | 244.0 | 35.0 | False | None | None | False | None | False | 8540.0 | 0 | | 3299478 | 115006 | None | code129 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box8 module | Each | 302.0 | 302.0 | 40.0 | False | None | None | False | None | False | 12080.0 | 0 | | 3299479 | 115006 | None | code130 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 10 -12 Module | Each | 363.0 | 363.0 | 40.0 | False | None | None | False | None | False | 14520.0 | 0 | | 3299480 | 115006 | None | code131 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate6 amps one way switch | Each | 88.0 | 88.0 | 280.0 | False | None | None | False | None | False | 24640.0 | 0 | | 3299481 | 115006 | None | code132 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate6 amps two way switch | Each | 152.0 | 152.0 | 2.0 | False | None | None | False | None | False | 304.0 | 0 | | 3299482 | 115006 | None | code133 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate6 Amps 3 way sockets | Each | 162.0 | 162.0 | 75.0 | False | None | None | False | None | False | 12150.0 | 0 | | 3299483 | 115006 | None | code134 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch platestepped fan Regulator's | Each | 313.0 | 313.0 | 43.0 | False | None | None | False | None | False | 13459.0 | 0 | | 3299484 | 115006 | None | code135 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate16A one way switch | Each | 249.0 | 249.0 | 36.0 | False | None | None | False | None | False | 8964.0 | 0 | | 3299485 | 115006 | None | code136 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate32 A DP switch | Each | 375.0 | 375.0 | 60.0 | False | None | None | False | None | False | 22500.0 | 0 | | 3299486 | 115006 | None | code137 | Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate6/16 Amps universal sockets | Each | 249.0 | 249.0 | 124.0 | False | None | None | False | None | False | 30876.0 | 0 | | 3299487 | 115006 | None | code138 | Supply and fixing one metal Fan box with round hook | Each | 163.0 | 163.0 | 28.0 | False | None | None | False | None | False | 4564.0 | 0 | | 3299488 | 115006 | None | code139 | Supply and fixing of Metal Socket set of 20A,230V, 2pole & Earth Plug & Socket on a suitable MS box for incorporating SP/TP MCB( without MCB) ,complete with internal connections with all accessories complete. | Each | 787.0 | 787.0 | 8.0 | False | None | None | False | None | False | 6296.0 | 0 | | 3299489 | 115006 | None | code140 | Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2)20 mm dia | Mtr | 61.0 | 61.0 | 1300.0 | False | None | None | False | None | False | 79300.0 | 0 | | 3299490 | 115006 | None | code141 | Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2)25 mm dia | Mtr | 80.0 | 80.0 | 850.0 | False | None | None | False | None | False | 68000.0 | 0 | | 3299491 | 115006 | None | code142 | Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 32mm dia 2.5mm thick | Mtr | 105.0 | 105.0 | 60.0 | False | None | None | False | None | False | 6300.0 | 0 | | 3299492 | 115006 | None | code143 | Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2)20 mm dia | Mtr | 75.0 | 75.0 | 550.0 | False | None | None | False | None | False | 41250.0 | 0 | | 3299493 | 115006 | None | code144 | Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2)25 mm dia | Mtr | 80.0 | 80.0 | 400.0 | False | None | None | False | None | False | 32000.0 | 0 | | 3299494 | 115006 | None | code145 | Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2)32mm dia 2.5mm thick | Mtr | 105.0 | 105.0 | 45.0 | False | None | None | False | None | False | 4725.0 | 0 | | 3299495 | 115006 | None | code146 | using one of FRLS PVC insulated 1100 v grade multistrand copper wire with low conductor resistance single core wire in open or concealed wiring system with specified IS-694:1990 and conforming to GTP of Group-A.1.5 Sq.mm | Mtr | 26.0 | 26.0 | 950.0 | False | None | None | False | None | False | 24700.0 | 0 | | 3299496 | 115006 | None | code147 | using one of FRLS PVC insulated 1100 v grade multistrand copper wire with low conductor resistance single core wire in open or concealed wiring system with specified IS-694:1990 and conforming to GTP of Group-A.2.5 sq.mm | Mtr | 40.0 | 40.0 | 750.0 | False | None | None | False | None | False | 30000.0 | 0 | | 3299497 | 115006 | None | code148 | using one of FRLS PVC insulated 1100 v grade multistrand copper wire with low conductor resistance single core wire in open or concealed wiring system with specified IS-694:1990 and conforming to GTP of Group-A.4 sq.mm | Mtr | 59.0 | 59.0 | 650.0 | False | None | None | False | None | False | 38350.0 | 0 | | 3299498 | 115006 | None | code149 | using one of FRLS PVC insulated 1100 v grade multistrand copper wire with low conductor resistance single core wire in open or concealed wiring system with specified IS-694:1990 and conforming to GTP of Group-A.6sq.mm | Mtr | 87.0 | 87.0 | 645.0 | False | None | None | False | None | False | 56115.0 | 0 | | 3299499 | 115006 | None | code150 | Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosureI- Single Door , 12 Way SP & N | Each | 1591.0 | 1591.0 | 2.0 | False | None | None | False | None | False | 3182.0 | 0 | | 3299500 | 115006 | None | code151 | Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosureIII - Double Door, 4 Way TPN DB | Each | 3053.0 | 3053.0 | 4.0 | False | None | None | False | None | False | 12212.0 | 0 | | 3299501 | 115006 | None | code152 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' cure, indicator ON/OFF, energy cross-3 with Short circuit breaking cappacity of 10K and complete wiring as required. Confirming to IEC 60898. (54/6.15)5-32Amps SP | Each | 523.0 | 523.0 | 64.0 | False | None | None | False | None | False | 33472.0 | 0 | | 3299502 | 115006 | None | code153 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' cure, indicator ON/OFF, energy cross-3 with Short circuit breaking cappacity of 10K and complete wiring as required. Confirming to IEC 60898. (54/6.15) 60-63Amps TPN | Each | 2399.0 | 2399.0 | 4.0 | False | None | None | False | None | False | 9596.0 | 0 | | 3299503 | 115006 | None | code154 | Supplying of on Load change Over Swich,4pole,AC-23A duty,415V,50Hz,AC-supply. 63 Amps | Each | 6391.0 | 6391.0 | 2.0 | False | None | None | False | None | False | 12782.0 | 0 | | 3299504 | 115006 | None | code155 | Supplying of on Load change Over Swich,4pole,AC-23A duty,415V,50Hz,AC-supply.125 Amps | Each | 11813.0 | 11813.0 | 2.0 | False | None | None | False | None | False | 23626.0 | 0 | | 3299505 | 115006 | None | code156 | Fixing of ..... Amps TPST / change over switch / Contactor along with neutral link with screws, bolts, nuts and wiring using required capacity wires and circuit labeling.15-63 Amps TPDT/COS | Each | 259.0 | 259.0 | 2.0 | False | None | None | False | None | False | 518.0 | 0 | | 3299506 | 115006 | None | code157 | Fixing of ..... Amps TPST / change over switch / Contactor along with neutral link with screws, bolts, nuts and wiring using required capacity wires and circuit labeling.100-250 Amps TPDT/COS | Each | 410.0 | 410.0 | 2.0 | False | None | None | False | None | False | 820.0 | 0 | | 3299507 | 115006 | None | code158 | Fabricating supplying and mounting MS box made out … SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. | Sq CM | 0.38 | 0.38 | 3000.0 | False | None | None | False | None | False | 1140.0 | 0 | | 3299508 | 115006 | None | code159 | Supplying and fixing 63A DP MCB miniature circuit breaker on the existing MCB distribution board ( Main / EMGPNL)using necessary fixing materials and wiring complete as required | Each | 1376.0 | 1376.0 | 2.0 | False | None | None | False | None | False | 2752.0 | 0 | | 3299509 | 115006 | None | code160 | Supplying and fixing 32A DP MCB miniature circuit breaker on the existing MCB distribution board (EMG PNL) using necessary fixing materials and wiring complete as required | Each | 1103.0 | 1103.0 | 16.0 | False | None | None | False | None | False | 17648.0 | 0 | | 3299510 | 115006 | None | code161 | Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker (ELMCB) 240/450V up to 300mA sensitivity on existing wood/panel board. 16-25 Amps 2 pole | Each | 2536.0 | 2536.0 | 6.0 | False | None | None | False | None | False | 15216.0 | 0 | | 3299511 | 115006 | None | code162 | Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker (ELMCB) 240/450V up to 300mA sensitivity on existing wood/panel board.32-40 Amps 4 pole | Each | 2826.0 | 2826.0 | 6.0 | False | None | None | False | None | False | 16956.0 | 0 | | 3299512 | 115006 | None | code163 | ELECTRICAL FIXTURES Supplying of ......feet - PVC Batten with integrated LED tube .....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition | Each | 740.0 | 740.0 | 67.0 | False | None | None | False | None | False | 49580.0 | 0 | | 3299513 | 115006 | None | code164 | Supplying of recess mounting non integral type .LED W luminaire comprising of pressure decast/extruded aluminium housing, with spring loaded fase ceiling clamps, Power LEDs with CCT 6500 degree K, CRI 70 efficac 100 lumen per watt, 120degree beam spread, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level. LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, , THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/ CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.(2 x 36 Watts) | Each | 5651.0 | 5651.0 | 4.0 | False | None | None | False | None | False | 22604.0 | 0 | | 3299514 | 115006 | None | code165 | Supply of LED floodlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/clear glass material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/ IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with .W System Power consumption. LED Efficiency 130lm/w,nominal CRI 75. Luminaire manufacturer should have inhouse facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 90012008 Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source 70Watts | Each | 7390.0 | 7390.0 | 6.0 | False | None | None | False | None | False | 44340.0 | 0 | | 3299515 | 115006 | None | code166 | Supply and fixing of Bulk Head Fitting with 1 No 15 W CFL Lamp. | Each | 952.0 | 952.0 | 19.0 | False | None | None | False | None | False | 18088.0 | 0 | | 3299516 | 115006 | None | code167 | Supplying of Exhaust Fan of 1440 RPM of 300mm (12") size with Bracket, blades complete for Light duty suitable to operate on 230V,50Hz, A.C.,supply | Each | 2997.0 | 2997.0 | 16.0 | False | None | None | False | None | False | 47952.0 | 0 | | 3299517 | 115006 | None | code168 | Supplying capacitor type 48" sweep ceiling fan complete with down rod blades , shackle canopies etc suitable for operation on 230V 50 cycles single phase AC supply conforming to ISS - 374 - 1979 and with double ball bearing system [Khaitan, Crompton greaves, Usha] | Each | 2085.0 | 2085.0 | 33.0 | False | None | None | False | None | False | 68805.0 | 0 | | 3299518 | 115006 | None | code169 | Supplying 300mm wall mounting fan suitable to operate at single phase 230v ac supply | Each | 2648.0 | 2648.0 | 2.0 | False | None | None | False | None | False | 5296.0 | 0 | | 3299519 | 115006 | None | code170 | Supplying and fixing 32 mm dia class A GI pipe bracket up to 2 mts long bent at suitable angle and fixing to this bracket 70 W MH street light fitting on wall using suitable clamps, bolts and nuts and wiring using suitable capacities of wires complete | Each | 1136.0 | 1136.0 | 4.0 | False | None | None | False | None | False | 4544.0 | 0 | | 3299520 | 115006 | None | code171 | Supplying and fixing of 45 mm dia heavy duty cable glands suitable or UG cable of 1.1 KV class metal only | Each | 194.0 | 194.0 | 8.0 | False | None | None | False | None | False | 1552.0 | 0 | | 3299521 | 115006 | None | code172 | Digging of Trench of 0.6M deep x 0.5M wide, refilling the Trench to reqd ground level & consolidating etc in hard soil (Ordinary) | Mtr | 102.0 | 102.0 | 38.0 | False | None | None | False | None | False | 3876.0 | 0 | | 3299522 | 115006 | None | code173 | Supplying and fixing of 65 mm DIA Class A GI Pipe of wall thickness not less than 3.25mm suitable or UG cable of 1.1 KV class | Mtr | 566.0 | 566.0 | 8.0 | False | None | None | False | None | False | 4528.0 | 0 | | 3299523 | 115006 | None | code174 | Supplying and fixing of 50Sqmm L.T.cast iron pot heads suitable for 1.1kv class UG cable filled with necessary bitumen/insulting compound complete with terminals ,clamps,bolts,nuts and washers etc. | Each | 618.0 | 618.0 | 4.0 | False | None | None | False | None | False | 2472.0 | 0 | | 3299524 | 115006 | None | code175 | Supplying , fixing , wiring earth electrode using 40 mm dia 2.9 mm thick GI pipe 2.5 mt long buried in a pit. The pit should be filled with equal proportion of salt and charcoal 150 mm alround the pipe to complete depth .The connection from the pipe is to be established through GI wire of size as ISI specifications 7.3.3. of IS732 using 12mm dia bolts nuts washers and check nuts etc;the pipe shall have 16 through holes of 12mm dia | Each | 2999.7 | 2999.7 | 12.0 | False | None | None | False | None | False | 35996.4 | 0 | | 3299525 | 115006 | None | code176 | Supplying and running of Gi wire of size 8 SWG for grounding connections using necessary fixing materials as required. | Rmtr | 19.0 | 19.0 | 65.0 | False | None | None | False | None | False | 1235.0 | 0 | | 3299526 | 115006 | None | code177 | Supplying and running of GI Strip of size 25 x 3mm for grounding connections using necessary fixing materials as required | Rmtr | 75.0 | 75.0 | 100.0 | False | None | None | False | None | False | 7500.0 | 0 | | 3299527 | 115006 | None | code178 | Supplying and drawing PVC flexible Two pair telephone unarmoured tinned copper cable of approved make | Rmtr | 13.0 | 13.0 | 110.0 | False | None | None | False | None | False | 1430.0 | 0 | | 3299528 | 115006 | None | code179 | Supplying and fixing sheet metal box of size 180x90x65 mm made out of 18 SWG sheet metal with necessary holes for cable / conduit entry as required with one coat of primer of approved make | Each | 155.0 | 155.0 | 4.0 | False | None | None | False | None | False | 620.0 | 0 | | 3299529 | 115006 | None | code180 | Plambing Providing and fixing Chorinated Poly Vinyl Chloride (CPVC) pipes conforming to IS 15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1 00 mtr spacing. This includes Jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete. (internal work exposed on wall)20 mm Dia | Rmtr | 315.18 | 315.18 | 550.0 | False | None | None | False | None | False | 173349.0 | 0 | | 3299530 | 115006 | None | code181 | Providing and fixing Chorinated Poly Vinyl Chloride (CPVC) pipes conforming to IS 15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1 00 mtr spacing. This includes Jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete. (internal work exposed on wall) 25 mm Dia | Rmtr | 384.19 | 384.19 | 125.0 | False | None | None | False | None | False | 48023.75 | 0 | | 3299531 | 115006 | None | code182 | Providing and fixing Chorinated Poly Vinyl Chloride (CPVC) pipes conforming to IS 15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1 00 mtr spacing. This includes Jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete. (internal work exposed on wall)40 mm Dia | Rmtr | 317.24 | 317.24 | 320.0 | False | None | None | False | None | False | 101516.8 | 0 | | 3299532 | 115006 | None | code183 | Providing and fixing brass bib cock of approved quality :15 mm nominal bore | Each | 335.78 | 335.78 | 13.0 | False | None | None | False | None | False | 4365.14 | 0 | | 3299533 | 115006 | None | code184 | 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g. | Each | 391.4 | 391.4 | 24.0 | False | None | None | False | None | False | 9393.6 | 0 | | 3299534 | 115006 | None | code185 | Providing and fixing CI Nahani trap of approved make conforming to ISI specifications and construction of Cistern in CC 1:2:4 as per directions (Rate is inclusive of cost of materials and fixtures and conveyance of materials to work spot). For 10cms x 7.5cms | Each | 257.5 | 257.5 | 26.0 | False | None | None | False | None | False | 6695.0 | 0 | | 3299535 | 115006 | None | code186 | Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depthof not less than 15 cms. with soft gravel or selected earth available fromthe excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for:PVC pipes 110mm dia., 6 kg/sqcm & class 3 | Rmtr | 405.82 | 405.82 | 590.0 | False | None | None | False | None | False | 239433.8 | 0 | | 3299536 | 115006 | None | code187 | Making Wall bores in Brick masonry upto 45 cm thick width for soil / water pipes including redoing with C.M ( 1:4 ) with all lead and lift as directed by Engineer-in-charge. | Each | 129.78 | 129.78 | 35.0 | False | None | None | False | None | False | 4542.3 | 0 | | 3299537 | 115006 | None | code188 | Providing and fixing PTMT grating of approved quality and colour.100 mm nominal dia | Each | 91.67 | 91.67 | 26.0 | False | None | None | False | None | False | 2383.42 | 0 | | 3299538 | 115006 | None | code189 | KSRB 13-11.1 : Providing and placing on terrace, polyethylenewater storage tank. IS:12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. | Ltr | 8.24 | 8.24 | 15000.0 | False | None | None | False | None | False | 123600.0 | 0 |
|